installation process tower tank

Upload: bill080808

Post on 07-Mar-2016

215 views

Category:

Documents


0 download

DESCRIPTION

WATER reserve tanks

TRANSCRIPT

  • 1 32 4

    5

    When choosing the correct site to install an Ecotank water storage tank, it is important to take into account any applicable regional or national rules and/or regulations regarding this type of installation.

    The person installing the tank must assess the installation site in terms of environmental conditions such as topography, geology, inclination, potential ood areas, landscape, surface run-o, and vegetation, among others. This is necessary to ensure none of the above factors interferes with the systems correct functioning or puts the structural integrity of the tank at risk.

    Choosing an incorrect installation site or ignoring environmental factors that can potentially damage the tank will void the product guarantee.

    The best tank

    ECOTANK WATER STORAGE TANK INSTALLATION MANUAL

    You have purchased an Ecotank water storage tank. To ensure correct installation, we suggest reading the recommendations provided in this document.

    WARNING!Non-compliance with the recommendations contained in this manual will void the product guarantee.

    INSTALLATION SITE RECOMMENDATIONS

    RECOMMENDATIONS FOR CORRECT INSTALLATION

    Place tank vertically on a level surface and make sure to remove any rocks that could damage the tank bottom. It is recommended to place the tank above a slab

    Make sure the ground where tank is to be installed is rm and compact. If very soft or a landll, partially replace with compacted select ll material. For further details, consult an engineer.

    When connecting the tank to a pumping system, be sure to install a vent pipe at the top of the tank. Pipe diameter must be at least 38 mm (1 ).

    When tank is installed on an inclined surface, the ground must be correctly contained and rainwater adequately canalized.

    In order to minimize movement, fasten the water pipe to a support near its connection to the tank (30 - 50 cm). This will decrease pressure exercised on the tank wall by any movement of the pipe, especially if a pump is installed.

    Selectmaterial

    ll

    Embankment

    Ventilation pipe

    Pipe support

    Tankconnection

  • Tower TowerEcotank

    1 2 3

    4 5

    9

    6

    7 8

    lacasadeltanque.com

    Male Adaptor 1/2

    Float Valve

    Filter (optional)

    MulticonnectorPVC Tee 1/2

    Checkvalve Bypass Valve

    Water input andoutput

    Entry pipe support

    Flange ontank

    PVC Elbow 1/2

    lacasadeltanque

    INSTALLATION PRECAUTIONS

    Do not mount tank on an inclined platform.

    Do not mount tank on a platform that is smaller than the tank base.

    Do not place tank on an uneven surface.

    Do not mount tank on blocks. Should you choose to do so, the space between these should not exceed 3 cm.

    Do not install tank below ground.

    Do not place tank on crushed stone, vegetation, roots or other elements that could damage the tank bottom.

    Never install tank in a position other than specied.

    Do not manipulate tank if full or partially full of water.

    Do not install tank on ground with surface water run-o or in areas prone to ooding.

    GENERAL RECOMMENDATIONS

    Make sure to wash tanks before installing to remove any contaminating particles that might be inside due to handling and/or transportation. Tank should be cleaned every six months to remove particles and sediment. Make sure to properly close tank lid so that sunlight and especially UV rays do not promote algae growth. Do not use bent or twisted pipes or hoses to make connections as this puts stress on the connection to the tank. When using a pumping system, fasten the entry pipe to a support in order to minimize movement. Tank installation site must be easily accessible for inspection and correct maintenance. Never use sharp objects to manipulate the tank (including a forklift) as these can perforate the tank. When storing tank before installation, make sure it is stored in a vertical position on a level surface. Temperature of liquid stored inside the tank must not exceed 60C. Before installing any accessories, make sure to ask an authorized dealer. Tanks are not fire resistant. Do not use or store near an open ame or heat above 80 C. Do not obstruct or seal access to the tank inspection lid. To ensure adequate water pressure in the case of elevated tanks, there must be a distance of at least 2 m between the tank base and highest supply pipe (shower, for example).

    GUARANTEEECOTANK guarantees that its products are free from manufacturing and/or material defects provided these are used in compliance with their intended use. However, in the event of a manufacturing and/or material defect within 5 years from the date of manufacturing, ECOTANK shall choose at its own discretion to satisfy a guarantee claim by either repairing or replacing this product. The companys liability shall be limited to the cost of the cistern excluding costs related to installation, removal of damaged product or any resulting damages.

    Neither ECOTANK nor any of its authorized distributors in Central America shall be held liable for indirect damages or product defects resulting from incorrect installation or failure to observe the above instructions and recommendations. This guarantee does not cover transportation or labor-related costs resulting from incorrect installation. The factory guaran-tee only covers manufacturing defects.

    ECOTANK tanks must be used in compliance with their intended use as described herein. Otherwise, this ECOTANK product guarantee shall be considered null and void and ECOTANK shall not be held liable for any resulting damages.

    This standard limited guarantee shall not apply in the case of damages resulting from improper use, incorrect use of recommended materials, accidents, installation, failure to observe procedures or incorrect maintenance.

    PIPE INSTALLATION DIAGRAM