installation with cable with socket continuous - comlux classic 2015/04_fluorescent water...ting...

4
126 acc. 372 quick con- nector socket grey 998042-00 Always to be used for continuous line with wire or tube, adding accessory 370. Cable gland with inlet cable 16A min. ø 9 max ø12 mm. 10 per pack. acc. 370 connec- tor for ø20 tube grey 998040-00 For use with acc. 371- 372 tube connector installation. 10 per pack. acc. 371 quick con- nector plug grey 998041-00 Always to be used for continuous line with wire or tube. Cable gland with inlet cable 16A min. ø 9 max ø12 mm. 10 per pack. Installation examples Hydro Installation with cable Continuous electric line con- nection using accessory 371 plug. Installation with tube Continuous electric line connection with tube using accessory 370 + 371 plug Installation with socket Continuous electric line con- nection using accessory 372 socket. Installation with tube Continuous electric line connection with tube using accessory 370 + 372 socket Example of continuous line installation with electrical wire. Can be installed with lighting fitting art. 958/959/960 on art. 6000 + acc. 6036. Example of continuous line installation with plug connector. Can be installed with standard lighting fitting on electrified tracks. The following arrangements can be obtained using accessories 370- 371-372 with the lighting fittings and with sub-code 0072. Installation with cable, installation with tube, installation with socket. A through-line wiring arrangement and socket/plug type connectors from the first of the last lighting fitting is required for this type of installation. (Lighting fitting supplied on request sub-code 0072 with surcharge). Warning: the last light fitting must be of the standard type art. 959/960 the suggestion is to install maximum 20 pcs of light fittings as continuous line, depending on the wattage of all the items. art. 959/960 Lighting fitting supplied on request Lighting fitting supplied on request with sub-code 0072 Socket connector Plug connector water-proof art. 959/960

Upload: trandang

Post on 20-Mar-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation with cable with socket Continuous - Comlux CLASSIC 2015/04_Fluorescent Water...ting fitting; complete with plug con-nector and lampsTo buy separa. - tely socket connector

126

Acc.371

Acc.372

Acc.370

Acc.370

Acc.371

Acc.372

Acc.370

Acc.371

Acc.371Acc.372

Acc.370

Acc.372

Art.6000

=

+

+ =

=

126

acc. 372 quick con-nector socket

grey 998042-00

Always to be used for continuous line with wire or tube, adding accessory 370. Cable gland with inlet cable 16A min. ø 9 max ø12 mm. 10 per pack.

acc. 370 connec-tor for ø20 tube

grey 998040-00

For use with acc. 371-372 tube connector installation. 10 per pack.

acc. 371 quick con-nector plug

grey 998041-00

Always to be used for continuous line with wire or tube. Cable gland with inlet cable 16A min. ø 9 max ø12 mm. 10 per pack.

Installation examples Hydro

Installation with cable Continuous electric line con-nection using accessory 371 plug.

Installation with tubeContinuous electric line connection with tube using accessory 370 + 371 plug

Installation with socketContinuous electric line con-nection using accessory 372 socket.

Installation with tubeContinuous electric line connection with tube using accessory 370 + 372 socket

Example of continuous line installation with electrical wire.

Can be installed with lighting fitting art. 958/959/960 on art. 6000 + acc. 6036.

Example of continuous line installation with plug connector.

Can be installed with standard lighting fitting on electrified tracks.

The following arrangements can be obtained using accessories 370-371-372 with the lighting fittings and with sub-code 0072. Installation with cable, installation with tube, installation with socket.

A through-line wiring arrangement and socket/plug type connectors from the first of the last lighting fitting is required for this type of installation. (Lighting fitting supplied on request sub-code 0072 with surcharge).

Warning: the last light fitting must be of the standard type art. 959/960 the suggestion is to install maximum 20 pcs of light fittings as continuous line, depending on the wattage of all the items.

art. 959/960Lighting fitting supplied on request

Lighting fitting supplied on request with sub-code 0072

Socket connector

Plug connector water-proof art.

959/960

Page 2: Installation with cable with socket Continuous - Comlux CLASSIC 2015/04_Fluorescent Water...ting fitting; complete with plug con-nector and lampsTo buy separa. - tely socket connector

127

460/910

690/1300/1600

15292

97 102

FL...FD

G13

FL...FDH

G5

959 - FL 1x36

5˚5˚ 15˚15˚ 25˚25˚ 35˚35˚

45˚45˚

55˚55˚

65˚65˚75˚75˚85˚85˚95˚95˚105˚105˚115˚115˚

40

80

120

160

200cd/Klm

IP66IK08ENEC F

16A

959 - FL 2x36

5˚5˚ 15˚15˚ 25˚25˚35˚35˚

45˚45˚

55˚55˚

65˚65˚

75˚75˚

85˚85˚

95˚95˚

105˚105˚

115˚115˚

40

80

120

160

200cd/Klm

LED

FLUO

RESC

ENT

WAT

ER-P

ROO

F

Hydro: complete with connector

"Assembled and ready to use" ligh-ting fitting; complete with plug con-nector and lamps. To buy separa-tely socket connector (acc. 372).

Water-proof lighting fitting on re-quest with stainless steel latches to be ordered using sub-code 0077 at an extra price. 959 Hydro T8 - electronic with connector

CELL-F Lamps (Ta=25°C)wattage colour weight code Kelvin - ølm - Ra

FL 1x36 grey 2.20 164631-00 4000K - 3350lm - Ra 1bFL 1x58 grey 2.90 164632-00 4000K - 5200lm - Ra 1bFL 2x36 grey 2.50 164633-00 4000K - 3350lm - Ra 1bFL 2x58 grey 3.10 164634-00 4000K - 5200lm - Ra 1b

960 Hydro T5 - electronic with connectorCELL-F Lamps (Ta=25°C)

wattage colour weight code Kelvin - ølm - Ra

FL 1x28 grey 2.00 164641-00 4000K - 2650lm - Ra 1bFL 1x49 grey 2.10 164642-00 4000K - 4350lm - Ra 1bFL 2x28 grey 3.20 164646-00 4000K - 2650lm - Ra 1bFL 2x49 grey 2.60 164647-00 4000K - 4350lm - Ra 1b

WATTAGE CONSUMPTION

A traditional water-proof lighting fitting normally requires 2 persons to be installed .... only one person is required with the new HYDRO series. Installing the HYDRO water-proof ceiling fitting is quicker, easier and more economic!In particular, recommended in the case of medium-large size systems.

Rapid connection solution is possible for: • continuous line installation (sub-code: 0072) • multi-pole cable installation (standard ceiling fitting) Ø 20 rigid PVC duct (ceiling fitting + acc 370)

QUICK INSTALLATION=

ECONOMIC SAVING

art. HYDRO 921/923 Time art. HYDRO 959/960 Time

Open the packing 45 sec Open the box and connect the quick connector 1 min

Mount the hooks and fit the lamp holder 1,5 min Mount the hooks and fit the lamp holder 0 min

Mount the cable gland and connect the ballast 2,5 min Mount the cable gland and connect the ballast 0 min

Position the wiring plate, mount the lamps 45 sec Position the wiring plate, mount the lamps 0 min

Introduce the shell and close the unit 30 sec Introduce the shell and close the unit 0 min

Total Total

6 min 1 min

EFF.=upp. 7,79%low. 63,61%tot. 71,4%

BZ= 9/4.0-8

EFF.=upp. 12,22%low. 64,78%tot. 77%BZ=10/3.0-8

Page 3: Installation with cable with socket Continuous - Comlux CLASSIC 2015/04_Fluorescent Water...ting fitting; complete with plug con-nector and lampsTo buy separa. - tely socket connector

128

cd/Klm

60

100

140

180

220

20

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

cd/Klm

75

125

175

225

275

325

25

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

11001400

65

15211401440

124

11001400

14001700

140

195275

30 555

140

35

100

73,5

47

26

37

25

50

22

921 - FL 1x36 + acc. 939

921 - FL 2x36 + acc. 940

cd/Klm

60

100

140

180

220

20

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°921 - FL 2x58 + acc. 942

acc. 939 narrow beam reflector1x36/28 998050-001x58/49 998051-00

Polished aluminium 99.85 narrow-beam reflector. To be installed with the white reflector already included in the fixture.

Accessories for Hydro

EFF.TOT. 78,5%upp.7,0low. 71,5%BZ = 8/3.0-7

EFF.TOT. 78,5%upp.6,1low. 72,4%BZ = 7/3.0-7

Recommended for pre-mises approximately 3-6 metres high. Total increase in efficiency +7%. Efficiency on the lower hemisphere between 0°-45° +25%.

Recommended for premi-ses over 4 metres high, or where intensive light is required. Total increase in efficiency + 4.8%. Efficiency on the lower hemisphere between 0°-45° + 36%.

Recommended for premi-ses over 4 metres high, or where intensive light is required. Total increase in efficiency + 4.8%. Efficiency on the lower hemisphere between 0°-45° + 36%.

EFF.TOT. 72,1%upp.5,3% low. 66,8%BZ = 7/4.0-7

acc. 940 narrow beam reflector2x36/28 998052-002x58/49 998053-00

Polished aluminium 99.85 narrow-beam reflector. To be installed with the white reflector already included in the fixture.

acc. 942 wide beam reflector2x36/28 998054-002x58/49 998055-00

Polished aluminium 99.85 wide-beam reflector. To be installed with the white reflector already included in the fixture.

acc. 936 screws for latchesblack 998071-00

Stainless steel self-tapping screws. For vandal resistant hook fastening. Pack contains 100 bags, 4 screws each.

acc. 978 wall bracketgalvanized 998078-00

Made of galvanized steel. For installa-tion of Hydro fixtures on walls.

acc. 938 junction sleeve998073-00

Polycarbonate, for jointing and transit of power supply cables (internal Ø 13 mm) between lighting fixtures (max distance 30 m). 2 per pack.

acc. 461 stainless steel latches18 997315-0028/36 997316-0058/80 997317-00

18= set with 6 hooks36/28 = set with 8 hooks58/80 = set with 10 hooks

acc. 6036 universal conn.galvanised 132987-00

Made of galvanized steel. To install non-corrosive fixtures on track art. 6000.

acc. 46 knife switch985034-00

For automatic connection to power supply and disconnection during maintenance. (excluded versions with lamps FL 1x18 and FL 2x18)

acc. 975 protection guard1x36 165564-001x58 165565-002x36 165566-002x58 165567-00

White plastic-coated steel rod. To be installed directly on the ceiling.

Page 4: Installation with cable with socket Continuous - Comlux CLASSIC 2015/04_Fluorescent Water...ting fitting; complete with plug con-nector and lampsTo buy separa. - tely socket connector

129

981 - FL 2x58 + acc. 967

20

60

100

140

180

220

260cd/Klm

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

981 - FL 2x58 + acc. 968

25

75

125

175

225

275

325cd/Klm

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

981 - FL 2x58 + acc. 969

50

150

250

350

450

550

650cd/Klm

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

384

11701470125

7912911590

210

12911590

79

210

12911590

79

210

68

FL...FDH

G5

FL...FD

G13

981 - FL 2x36

20

60

100

140

180

220

260cd/Klm

115°

105°95°

85°75°

55°

45°

35°

105°95°

85°75°

55°

45°

35°25° 15° 25°5° 5° 15°

65°65°

115°

126 108

900

1300/1600

136

136

IP65IK08 F

FLUO

RESC

ENT

WAT

ER-P

ROO

F

Lunar

Housing: injection moulded, van-dal resistant, self-extinguishing, UV stabilised RAL 7035 grey polycar-bonate, high mechanical resistance thanks to the stiffening ribs inside the structure.Diffuser: Anti-glare protective tube made of impact resistant, self-extin-guishing, UV-stabilised, dustpro-of, anti-yellowing treated V2 clear polycarbonate, scored inside and smooth outside.On request: versions with 3 hour emergency duration.

acc. 937 ceiling bracketstainless s. 998072-00

Made of stainless steel (AISI 304). Package holds 100 bags containing 2 brackets + 2 screws each. Price per pack.

1-Lamp 2-Lamps

Accessory 937 ceiling bracketThe device enables bracket movements for quick and easy installation.

EFF.TOT.64,7 %

EFF.TOT.70,4 %

EFF.TOT.69,8 %

e/h = 1,25BZ = 4/0.8-3

e/h = 1,5BZ = 6/3.0-5

e/h = 1,5BZ = 6/1.5-5

981 Lunar T8 ENEC

CEL CEL-Ewattage colour weight code weight code

FL 1x36 grey 1.70 166442-08 2.20 166442-09FL 1x58 grey 2.40 166443-08 2.90 166443-09FL 2x36 grey 2.00 166445-08 2.50 166445-09FL 2x58 grey 2.60 166446-08 3.10 166446-09

acc. 967 steel reflector 1/2x36 166554-001/2x58 166555-001/2x28 166562-001/2x49 166563-00

Cost-effectiveness, improved illuminance and light control. Steel painted white

acc. 968 aluminium reflector 1/2x36 166556-001/2x58 166557-001/2x28 166564-001/2x49 166565-00

Better light control. Made of polished aluminium 99.85.

acc. 969 narrow beam reflector1x36 166558-001x58 166559-002x36* 166560-002x58* 166561-001x28 166566-001x49 166567-002x28 166568-002x49 166569-00

Made of polished aluminium 99.85. *Two-lamp versions without reflector.

981 Lunar T5CEL CEL-E

wattage colour weight code weight code

FL 1x28 grey 1.50 166450-00 2.00 166450-07FL 1x49 grey 2.20 166460-00 2.70 166460-07FL 2x28 grey 1.80 166470-00 2.30 166470-07FL 2x49 grey 2.40 166480-00 2.90 166480-07

EFF.TOTupp. 27,4%low. 57,2%tot. 84,6%e/h= 1,5

BZ= 8

acc. 938 junctionsleeve