DEVELOPMENTS IN FOOD SCIENCE 39

I N S T R U M E N T A L M E T H O D S I N F O O D A N D B E V E R A G E A N A L Y S I S

Page 3: Instrumental

This Page Intentionally Left Blank

Page 4: Instrumental

DEVELOPMENTS IN FOOD SCIENCE 39

I N S T R U M E N T A L M E T H O D S IN F O O D A N D B E V E R A G E A N A L Y S I S

Edited by DAVID LOUIS BENTE WETZEL GEORGE CHARALAMBOUS t

1998 E L S E V I E R A m s t e r d a m - L a u s a n n e - N e w Y o r k - O x f o r d - S h a n n o n - S i n g a p o r e - T o k y o

Page 5: Instrumental

ELSEVIER SCIENCE B.V. Sara Burgerhartstraat 25 P.O. Box 211, 1000 AE Amsterdam, The Netherlands

Library of Congress Cataloging in Publication Data A catalog record from the Library of Congress has been applied for.

ISBN: 0-444-82018-3

�9 1998 Elsevier Science B.V. All rights reserved.

No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the publisher, Elsevier Science B.V., Copyright & Permissions Department, P.O. Box 521, 1000 AM Amsterdam, The Netherlands.

Special regulations for readers in the USA - This publication has been registered with the Copyright Clearance Center Inc. (CCC), 222 Rosewood Drive, Danvers, MA, 01923. Information can be obtai- ned from the CCC about conditions under which photocopies of parts of this publication may be made in the USA. All other copyright questions, including photocopying outside of the USA, should be refe- rred to the copyright owner, Elsevier Science B.V., unless otherwise specified.

No responsibility is assumed by the publisher for any injury and/or damage to persons or property as a matter of products liability, negligence or otherwise, or from any use or operation of any methods, products, instructions or ideas contained in the material herein.

O The paper used in this publication meets the requirements of ANSI/NISO Z39.48-1992 (Permanence of Paper)

Printed in The Netherlands

Page 6: Instrumental

DEVELOPMENTS IN FOOD SCIENCE

Volume 1

Volume 2

Volume 3

Volume 4

Volume 5

Volume 6

Volume 7

Volume 8

Volume 9

Volume 10

Volume 11

Volume 12

Volume 13

Volume 14

Volume 15

Volume 16

Volume 17

Volume 18

Volume 19

Volume 20

J.G. Heathcote and J.R. Hibbert Aflatoxins: Chemical and Biological Aspects H. Chiba, M. Fujimaki, K. Iwai, H. Mitsuda and Y. Morita (Editors) Proceedings of the Fifth International Congress of Food Science and Technology I.D. Morton and A.J. MacLeod (Editors) Food Flavours Part A. Introduction Part B. The Flavour of Beverages Part C. The Flavour of Fruits Y. Ueno (Editor) Trichothecenes: Chemical, Biological and Toxicological Aspects J. Holas and J. Kratochvil (Editors) Progress in Cereal Chemistry and Technology. Proceedings of the VIIth World Cereal and Bread Congress, Prague, 28 june-2 July 1982 I. Kiss Testing Methods in Food Microbiology H. Kurata and Y. Ueno (Editors) Toxigenic Fungi: Their Toxins and Health Hazard. Proceedings of the Mycotoxin Symposium, Tokyo, 30 August-3 September 1983 V. Betina (Editor) Mycotoxins: Production, Isolation, Separation and Purification J. Hollo (Editor) Food Industries and the Environment. Proceedings of the International Symposium, Budapest, Hungary, 9-11 September 1982 J. Adda (Editor) Progress in Flavour Research 1984. Proceedings of the 4th Weurman Flavour Research Symposium, Dourdan, France, 9-11 May 1984 J. Hollo (Editor) Fat Science 1983. Proceedings of the 16th International Society for Fat Research Congress, Budapest, Hungary, 4-7 October 1983 G. Charalambous (Editor) The Shelf Life of Foods and Beverages. Proceedings of the 4th International Flavor Conference, Rhodes, Greece, 23-26 July 1985 M. Fujimaki, M. Namiki and H. Kato (Editors) Amino-Carbonyl Reactions in Food and Biological Systems. Proceedings of the 3rd International Symposium on the Maillard Reaction, Susuno, Shizuoka, Japan,l-5 July 1985 J. Skoda and H. Skodova Molecular Genetics. An Outline for Food Chemists and Biotechnologists. D.E. Kramer and J. Liston (Editors) Seafood Quality Determination. Proceedings of the International Symposium, Anchorage, Alaska, U.S.A., 10-14 November 1986 R.C. Baker. P. Wong Hahn and K.R. Robbins Fundamentals of New Food Product Development G. Charalambous (Editor) Frontiers of Flavor. Proceedings of the 5th International Flavor Conference, Porto Karras, Chalkidiki, Greece, 1-3 July 1987 B.M. Lawrence, B.D. Mookherjee and B.J. Willis (Editors) Flavors and Fragrances: A World Perspective. Proceedings of the 10th International Congress of Essential Oils, Fragrances and Flavors, Washington, DC, U.S.A., 16-20 November 1986 G. Charalambous and G. Doxastakis (Editors) Food Emulsifiers: Chemistry, Technology, Functional Properties and Applictations B.W. Berry and K.F. Leddy Meat Freezing. A Source Book

Page 7: Instrumental

Volume 21

Volume 22

Volume 23

Volume 24

Volume 25

Volume 26

Volume 27

Volume 28

Volume 29

Volume 30

Volume 31

Volume 32

Volume 33

Volume 34

Volume 35

Volume 36

J. Davidek, J. Veli~ek and J. Pokorny (Editors) Chemical Changes during Food Processing V. Kyzlink Principles of Food Preservation H. Niewiadomski Rapeseed. Chemistry and Technology G. Charalambous (Editor) Flavors and Off-flavors '89. Proceedings of the 6th International Flavor Conference, Rehymnon, Crete, Greece, 5-7 July 1989 R. Rouseff (Editor) Bitterness in Foods and Beverages J. Chelkowski (Editor) Cereal Grain. Mycotoxins, Fungi and Quality in Drying and Storage M. Verzele and D. De Keukeleire Chemistry and Analysis of Hop and Beer Bitter Acids G. Charalambous (Editor) Off-Flavors in Foods and Beverages G. Charalambous (Editor) Food Science and Human Nutrition H.H. Huss, M. Jakobsen and J. Liston (Editors) Quality Assurance in the Fish Industry. Proceedings of an International Conference, Copenhagen, Denmark, 26-30 August 1991 R.A. Samson, A.D. Hocking, J.I.Pitt and A.D. King (Editors) Modern Methods in Food Mycology G. Charalambous (Editor) Food Flavors, Ingredients and Composition. Proceedings of the 7th International Flavo Conference, Pythagorion, Samos, Greece, 24-26 June 1992 G. Charalambous (Editor) Shelf Life Studies of Foods and Beverages. Chemical, Biological, Physical and Nutritional Aspects G. Charalambous (Editor) Spices, Herbs and Edible Fungi H. Maarse and D.G. van der Heij (Editors) Trends in Flavour Research. Proceedings of the 7th Weurman Flavour Research Symposium, Noordwijkerhout, The Netherlands, 15-18 June 1993 J.J. Bimbenet, E. Dumoulin and G. Trystram (Editors) Automatic Control of Food and Biological Processes. Proceedings of the ACoFoP III Symposium, Paris, France, 25-26 October 1994

Volume 37A+B G. Charalambous (Editor) Food Flavors: Generation, Analysis and Process Influence Proceedings of the 8th International Flavor Conference, Cos, Greece, 6-8 July 1994

Volume 38 J.B. Luten, T. Borresen and J. Oehlenschl&ger (Editors) Seafood from Producer to Consumer, Integrated Approach to Quality Proceedings of the International Seafood Conference on the occasion of the 25th anniversary of the WEFTA, held in Noordwijkerhout, The Netherlands, 13-16 November 1995

Volume 39 D. Wetzel and G. Charalambous t (Editors) Instrumental Methods in Food and Beverage Analysis

Page 8: Instrumental

vii

Dedication

This volume devoted to Instrumental Analysis for Food and Beverage Analysis is dedicated to the late Dr. George Charalambous whose contributions to agriculture and food chemistry were not limited to his own work in the flavor area. His vision, always forward, was like the high beam of automobile headlights exploring the distant future down the road and fanning out slightly to the center lane and the shoulder of the road for a glimpse of new unexpected things that may lie ahead and become important in the future.

His curiosity made him an attentive listener and formulator of pertinent questions as he mentally explored unfamiliar territory that those who shared his joumey in the direction of progress may benefit from. He was interested in new and potentially useful approaches and in new instrumental techniques. George recognized the value of one-on-one or small group discussion as a provocative form of scientific communication. He organized scientific conferences where travelers on the road to success in food and flavor chemistry could pause for refreshment or charge their intellectual batteries before proceeding on their journey. He understood the human and cultural side of those in the scientific community and appropriately staged the conferences he organized with that in mind. His charm persuasion and persistence brought both the published proceedings (a living text) and the conferences to fruition.

At the time that George was putting together his last two volume collection of papers from the Intemational Conference in Cos, Greece, I received a call from him at my home at some odd hour and he said in reference to one chapter, "It took me two hours to read and study the thing and I'm still excited." Our dear colleague was blessed to the end of his day with a keen mind and the curiosity that made his approach to new "tools of science" with the enthusiasm of a boy opening a package containing a new toy. It was he who initially planned this volume and identified the experts in each area to participate.

Page 9: Instrumental

This Page Intentionally Left Blank

Page 10: Instrumental

ix

Preface

Advances in instrumentation and applied instrumental analysis methods have allowed scientists concemed with food and beverage quality, labeling, compliance, and safety to meet ever increasing analytical demands. Texts dealing with instrumental analysis alone are usually organized by the techniques without regard to applicaitons. The biannual review issue of Analytical Chemistry under the topic of Food Analysis is organized by the analyte such as N and protein, carbohydrate, inorganics, enzymes, flavor and odor, color, lipids, and vitamins. That review introduces at least seven instrumental techniques under the first topic and in successive topics some of the techniques are revisited and new ones are introduced as needed. Finally under flavor and odor the subdivisions are not along the lines of the analyte but the matrix (e.g. wine, meat, dairy, fruit) in which the analyte is being determined.

Approximately 200 references were cited that appeared in a two year period. Molecular spectroscopy, chromatographic or other sophisticated separations as well as hyphenated techniques such as GC-Mass spectrometry usually predominate. The reader is referred to a list of 72 entries on page III entitled "Instrumentation and Instrumental Techniques" that appear in this book. In the text of Instrumental Methods in Food and Beverage Analysis, a few of these appear under a chapter named for the technique. Most of the analytical techniques used for determination, separations and sample work up prior to determination are treated in the context of an analytical method for a specific analyte in a particular food or beverage matrix. The instruments and techniques are applied to an analyte and sample matrix with which the author has a professional familiarity, dedication, and authority.

In food analysis in particular it is usually the food matrix that in fact presents the research analytical chemist involved with method development the greatest challenge. Incoming analytical graduate students are made aware of one infamous case in particular. A heat stable form of a dough conditioner, shelf-life extender, and nutrient had been synthesized and its value was dependent upon proving its survival of the baking condition. It required only a day to fred excellent HPLC conditions to separate and determine the particular surface active agent from a concentrate, but it took the rest of the year to establish an actual method for the analyte in the food matrix. Recovery was the key and therein was the analytical dilemma.

David L. B. Wetzel, Professor Kansas State University

Page 11: Instrumental

Instrumentation and Instrumental Techniques

ultraviolet spectrometry (UV) colorimetry, visible spectrometry Hunter reflectometer chemiluminescence laser induced fluorescence pyro-chemiluminescence infrared spectrometry near-infrared (NIR) spectrometry Fourier transform spectrometry FT-IR FT-NIR microspectrometry Raman spectroscopy acousto-optic tunable filter spectrometer (AOTF) grating monochromator diode array nuclear magnetic resonance spectrometry (NMR) ~3C cross polarization magic angle spinning NMR diffuse reflectance circular dichroism

solid phase extraction purge-and-trap technique flame ionization detection selected ion monitoring (SIM) elemental nitrogen analyzer chemiluminescent nitrogen detection electrochemical detection differential refractive index InGaAs detector light emitting diode (LED) micellar electrokinetic capillary chromatography centrifugal partition chromatography cyrofocusing coelectroosmotic electrophoresis counter electroosmotic electrophoresis isatachophoresis digital image analysis (DIA) enzyme-linked immunosorbent assays

(ELISA) low angle laser light scattering photometer (LALLS) Brabender amylograph enzymatic-spectrometric method mass spectrometry (MS) quadrupole mass spectrometry, 3-D electron impact ionization chemical ionization negative chemical ionization ion trapping high performance liquid chromatography (HPLC) reversed phase chromatography high performance size exclusion

chromatography (HPSEC) supercritical fluid chromatography (SFC) supercritical fluid extraction (SFE) field flow fractionation (FFF) gas chromatography (GC) fused silica capillary-GC

Brabender Viscograms viscometers viscoelasticity, linear and non-linear differential scanning calorimetry Coulter counter scanning electom microscopy (SEM) X-ray diffraction wide angle X-ray diffraction mass fragrnentographic SIM small deformation oscillatory measurements chemometrics multivariate statistics pattern recognition discriminant component analysis Euclidian distance Mahalanobis distance

Page 12: Instrumental

xi

LIST OF CONTRIBUTORS

Number in parenthesis indicate where contributions begin

O.R. Abou-Samaha (49) Food Science and Technology Department, Faculty of Agriculture, Alexandria University, Alexandria, Egypt

M.H. Bekheet (49) Food Science and Technology Department, Faculty of Agriculture, Alexandria University, Alexandria, Egypt

P.W. Bosland (347) Department of Agronomy and Horticulture, New Mexico state University, Box 30003, Las Cruces, New Mexico, U.S.A.

J. Brady (467) Hercules Inc., Research Center, 500 Hercules Road, Wilmington, DE 19808, U.S.A.

I. Chronakis (99) Physical Chemistry 1, Center for Chemistry and Chemical Engineering, Lund University, P.O. Box 124, S-22 100 Lund, Sweden

F. Colon (489) Chimie des Ar6mes-Oenologie, Associ6 au CNRS, URA 1411, Facult6 des Sciences et Techniques de St-J6r6me, Case 561, Avenue Escadrille Normandie-Ni6men F13397 Marseille C6dex 20, France

J. Crnko (379) Antek Instruments Inc., 300 Bammel Westfield Road, Houston, TX 77090, U.S.A.

T. Drumm Boylston (225) Southern Regional Research Cemer, U.S. Department of Agriculture, Agriculture, Agricultural Research Service, P.O. Box 19687, 1100 Robert E. Lee Boulevard, New Orleans, LA 70179, U.S.A. - Present address: Department of Food Science and Human Nutrition, Washington State University, Pullman, WA 991640-6376

C. Femandes (571) Department of Food Science and Technology, Virginia Tech, Blacksburg, VA 24061-0418, U.S.A.

G. Flick, Jr. (571) Department of Food Science and Technology, Virginia Tech, Blacksburg, VA 24061-0418, U.S.A.

E. Fujinari (377-475) 25411 Avery Hill Lane, Spring, TX 77373-6089, U.S.A.

F. Goycoolea (99) Research Center for Food and Development (C.I.A.D., A.C.), P.O. Box 1735, 83000 Hermosillo, Sonora, Mexico

A. Hoffmann (303) Gerstel GmbH, AktienstraBe 232-234, 45473 MiJlheim an der Ruhr, Germany

Page 13: Instrumental

xii

S. Kasapis (1) Department of Food Research and Technology, Cranfield University, Silsoe College, Silsoe, Bedford MK45 4DT, United Kingdom

B. Kibler (379) Antek Instruments Inc., 300 Bammel Westfield Road, Houston, TX 77090, U.S.A.

J.M. King (195) Department of Food Science and Technology, The Ohio State University, 122 Vivian Hall, 2121 Fyffe Road, Columbus, OH 43210, U.S.A.

F. Kolpak (467) Hercules Inc., Research Center, 500 Hercules Road, Wilmington, DE 19808, U.S.A.

C. Lageot (245) Chimie des Ar6mes-Oenologie, Associ6 au CNRS, URA 1411, Facult6 des Sciences et Techniques de St-J6r6me, Case 561, F13397 Marseille C6dex 20, France

K. MacNamara (303) Irish Distiller Limited, Bow Street Distiller, Smithfield, Dublin 7, Ireland

D.B. Min (195) Department of Food Science and Technology, The Ohio State University, 122 Vivian Hall, 2121 Fyffe Road, Columbus, OH 43210, U.S.A.

Y.G. Moharram (49) Food Science and Technology Department, Faculty of Agriculture, Alexandria University, Alexandria, Egypt

C. Pfirkfinyi (245) Department of Chemistry, Florida Atlantic University, PO Box 3091, Boca Raton FL 33431-0991, U.S.A.

R. Richardson (1) Department of Food Research and Technology, Cranfield University, Silsoe College, Silsoe, Bedford MK45 4DT, United Kingdom

H. Shi (475) Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24060, U.S.A.

B. Strode HI (475) Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24060, U.S.A.

L. Taylor (475) Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24060, U.S.A.

J. Thompson (475) Department of Chemistry, Virginia Polytechnic Institute and State University. Blacksburg, VA 24060, U.S.A.

G. Vemin (245 & 489) Chimie des Ar6mes-Oenologie, Associ6 au CNRS, URA 1411, Facult6 des Sciences et Techniques de St-J6r6me, Case 561, F13397 Marseille C6dex 20, France

Page 14: Instrumental

xiii

B. Vinyard (225) Southern Regional Research Center, U.S. Department of Agriculture, Agriculture, Agricultural Research Service, P.O. Box 19687, 1100 Robert E. Lee Boulevard, New Orleans, LA 70179, U.S.A.

M.M. Wall, (347) Department of Agronomy and Horticulture, New Mexico State University, Box 30003, Las Cruces, New Mexico, U.S.A.

D. Wetzel (141) Department of Grain Science and Industry, Kansas State University, 201 Shellenberger Hall, Manhattan, KS 66506, U.S.A.

R. Young (425) Shell Canada Products, Ltd., Scotford Ref'mery, Fort Saskatchewan, Alberta, Canada

Page 15: Instrumental

xiv

ERRATUM

Capillary Electrophoresis for Food Analysis (Custy F. Femandes and George J. Flick, Jr.) pp. 575-612

On pages 596 and 601, references in the text to figures 8 and 9 should be disregarded, as these figures were not included by the authors.

Page 16: Instrumental

XV

CONTENTS

Dedication .......................................................................................................................................... vii

Preface ............................................................................................................................................... ix

Instrumentation and Instrumental Techniques ................................................................................... x

List of Contributors ........................................................................................................................... xi

Rheological methods in the Characterisation of Food Biopolymers ROBERT K. RICHARDSON and STEFAN KASAPIS ....................................................... 1

Destructive and Non-Destructive Anal)r Methods in Starch Analysis Y.G. MOHARRAM, O.R. ABOU-SAMAHA, and M.H. BEKHEET ................................. 49

Specific Methods for the Analysis of Identity and Purity of Functional Food Polysaccharides FRANCISCO M. GOYCOOLEA and IOANNIS S. CHRONAKIS .................................... 99

Analytical Near-Infrared Spectroscopy DAVID L. B. WETZEL ....................................................................................................... 141

Analysis of Fatty Acids J.M. KING and D.B. MIN ................................................................................................... 195

Isolation of Volatile Flavor Compounds From Peanut Butter Using Purge-and-Trap Techniques TERRI DRUMM BOYLSTON and BRYAN T. VINYARD .............................................. 225

GC-MS(EI, PCI, NCI, SIM, ITMS) Data Bank Analysis of Flavors and Fragrances. Kovats indices G. VERNIN, C. LAGEOT, and C. P/kRKANYI ................................................................. 245

Gas Chromatographic Technology in Analysis of Distilled Spirits KEVIN MacNAMARA and ANDREAS HOFFMANN .................................................... 303

Page 17: Instrumental

xvi

Analytical Methods for Color and Pungency of Chiles (capsicums) M.M. WALL and P.W. BOSLAND .................................................................................... 347

Chemiluminescent Nitrogen Detectors (CLND) for GC, SimDis, SFC, HPLC and SEC Applications Dedication/Preface ............................................................................................................... 375

Part 1 Elemental Total Nitrogen Analyses by Pyro-Chemiluminescent Nitrogen Detection JOHN CRNKO, BOB C. KIBLER, and EUGENE M. FUJINARI ..................................... 379

Part 2 Gas Chromatography- Chemiluminescent Nitrogen Detection: GC-CLND EUGENE M. FUJINARI ..................................................................................................... 385

Part 3 Simulated Distillation-Chemiluminescent Nitrogen Detection: SimDis-CLND RICHARD J. YOUNG and EUGENE M. FUJINARI ......................................................... 425

Part 4 High Performance Liquid Chromatography- Chemiluminescent Nitrogen Detection: HPLC- CLND

EUGENE M. FUJINARI ..................................................................................................... 431

Part 5 The Determination of Compositional and Molecular Weight Distributions of Cationic Polymers Using Chemiluminescent Nitrogen Detection (CLND) in Aqueous Size Exclusion Chromatography

FRANK J. KOLPAK, JAMES E. BRADY, and EUGENE M. FUJINARI ........................ 467.

Part 6 Chemiluminescent Nitrogen Detection in Capillary SFC HENG SHI, J. THOMPSON, B. STRODE l]], LARRY T. TAYLOR, and EUGENE M. FUJINARI ..................................................................................................... 475

The SPECMA 2000 Data Bank Applied to Flavor and Frangrance Materials F. COLON and G. VERNIN ................................................................................................ 489

Capillary Electrophoresis for Food Analysis CUSTY F. FERNANDES and GEORGE J. FLICK, Jr ...................................................... 575

Index ................................................................................................................................................ 613

Page 18: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved

R H E O L O G I C A L METHODS IN THE FOOD B I O P O L Y M E R S

C H A R A C T E R I S A T I O N OF

Robert K. Richardson and Stefan Kasapis

Department of Food Research and Technology, Cranfield University, Silsoe College, Silsoe, Bedford MK45 4DT, United Kingdom

INTRODUCTION

All natural food systems contain biopolymers, often in the form of complex multicomponent mixtures, which play a fundamental role in their structure and function. Similarly, in processed foodstuffs, biopolymers are used widely to create a structured body, and in the case of high solid products (confectioneries) to maintain the rubbery (jelly babies, gummy bears, etc.) or glassy (boiled down sweets) texture required by the consumer. Furthermore, increasing consumer awareness of the health implications of a high calorie, low fibre diet and in particular of excess consumption of saturated fat has generated a large market for low fat or even zero fat substitutes for traditional yellow fat spreads (butter and margarine) and cheeses. Developments in the area of fat replacers centre on the use of carbohydrates, particularly maltodextrins (hydrolysed starch) and proteins (gelatin, milk proteins, etc.) to bind water within the product and to generate acceptable fat-like rheology (spreading behaviour) and ' mouthfeel'

Particularly important examples of polysaccharide and protein functionality, therefore, are the capacity to alter the flow characteristics of fluids and to interact in the hydrated state with other dispersed or dissolved molecular species which they may bind, chelate, complex, emulsify, encapsulate, flocculate, stabilise or suspend. As a result they perform, either by themselves or in association with hormones, lipids or other molecules, vital biological functions by providing structural support and energy reserve, and by mediating various other processes such as adhesion, cellular recognition and growth. This broad range of functional properties, frequently unique in their nature, originate from the primary structure of the individual residues and the configuration of the linkages between them which lead to the development of electrostatic, hydrophilic and dipole-dipole interactions, hydrogen bonding, and covalent associations (e.g. disulphide linkages in proteins) [1,2].

In the generation of a diversity of manufactured products, industrial processing often exploits the dramatic alteration of the physical properties of biopolymers when they undergo transformation from the fluctuating chain geometry, typical of the solution state, to the fixed, ordered conformations typically seen in gelling systems. At present, the only general route to detailed characterisation of polysaccharide ordered structures at atomic resolution is X-ray diffraction from ordered fibres. The single crystal X-ray diffraction patterns of globular proteins contain sufficient information for direct,

Page 19: Instrumental

unambiguous determination of macromolecular organisation and packing [3]. Things are less clear in the case of polysaccharides, but in general it is relatively easy to extract basic information such as helix pitch and overall dimensions of the repeating 'unit cell'. These, together with the known, and essentially invariant, ring geometry of the constituent sugars, and the C-O-C bond angle of the inter-residue linkage, normally restrict the stereochemically-feasible arrangements to a manageable number of candidate structures, whose anticipated diffraction patterns can be calculated and compared with observed intensifies [4].

Although fibre diffraction provides valuable (and indeed essential) information for detailed interpretation of the physical properties of polysaccharides, the existence of an ordered structure in the solid state does not necessarily imply that the same structure persists under hydrated conditions. The advent of microcomputing in recent years has allowed the rapid development of rheological techniques, with computer driven rheometers becoming commonplace in the laboratory. These are now established as the most productive line of attack for the development of function- structure-texture relationships in food products. Rheological measurements are performed therefore:

(i) to detect consequences of possible conformational order in solution (ii) to characterise changes in chain geometry and packing under

hydrated conditions (iii) to monitor any order-disorder transition behaviour [5].

Findings from such studies in vitro also provide significant insights into the probable in vivo behaviour of polysaccharides and proteins in complex natural systems (e.g. living plant cells). The aim of this Chapter is to describe the rheological techniques used in food biopolymer research for investigation of dilute and concentrated solutions, aqueous gels and high-solids systems, biphasic systems, and to indicate the principles on which they are based.

RHEOLOGY

In this section, it is intended to give a basic introduction to rheological techniques sufficient for the practical examination of biopolymer based sample systems, interpretation of results and to provide enough background information for the more detailed accounts of particular system types described later.

Definitions and Terms

The word rheology is derived from the Greek rheo meaning flow. Several defimtions have been advanced over the years but perhaps the most simple description is that rheology is the study of the relationship between stress and strain within a sample material as a function of time, temperature, etc. Stress is the force per unit area acting on a sample and therefore has the units of pressure, usually Nm ~ or Pa., strain being the resulting fractional deformation and therefore a dimensionless ratio.

Page 20: Instrumental

Two early laws of physics divided materials into two distinct types according to their observed mechanical behaviour; solids and liquids. In the former case, it was observed that stress (r is directly proportional to strain 0') [Hooke's law] and for liquids, stress is proportional to rate of strain (dy/dt) [Newton's law]. For a perfect Hookean solid, all the energy necessary for the deformation process is stored as recoverable potential energy whereas, in the case of a Newtonian liquid, all the energy contributing to flow is dissipated as heat. The proportionality constants for the two cases are termed modulus and viscosity which for simple shear measurements are given the symbols G = or/), and 11 = t~/(d),/dt). These classes of response represent 'extremes' of behaviour, most materials combining both elastic and viscous properties, giving rise to the term 'viscoelasticity'.

The simple, classical experiments used to determine viscoelastic properties involve measuring the time-dependence of either the stress due to a given strain, or the strain generated by a known stress. The former experiment, known as stress-relaxation, yields a time-dependent modulus, e.g. G(t) = or(t)/7, and the latter, creep experiment, gives the time-dependent compliance J(t) = ~,(t)/~.

Viscoelastic Behaviour

Viscoelasticity is often modelled using combinations of springs and dashpots as mechanical analogues of the independent elastic and viscous contributions. The two simplest forms are the Maxwell (series) element and the Voigt (parallel) element shown in Figures l a and l b respectively. The former represents a viscoelastic liquid and the latter, a viscoelastic solid and the response of these to a creep experiment is illustrated in Figures 2a and 2b.

In Figure l a, where the stress in both components is equal, the spring is instantaneously stretched and further increase in strain proceeds at a rate inversely proportional to the viscosity component. On removal of the imposed stress, the spring instantaneously relaxes and a residual strain, equal to the product of strain-rate and experimental time, remains. In the case of the Voigt element, the spring and dashpot experience equal strain at any given time and hence the initial stretching of the elastic component is 'damped' by the dashpot, the strain at long times approaching a constant value proportional to the compliance of the spring. Here, on removal of the stress, the relaxation of the spring is again damped but eventually, the displacement returns to the original zero-strain condition.

In general, the molecular processes in real viscoelastic materials are too complex to be described directly by such simple models. As the material structure becomes more complex, so the number of relaxation processes at different time-scales contributing to the overall mechanical properties, increases. The relaxation and creep measurements described above are, however, useful in determining the underlying long-range structure, i.e. if liquid-like or solid-like behaviour is displayed at long times.

Combinations of the model elements can also assist in making realistic predictions of overall response provided they truly represent discrete mechanical components such as 'sandwich' structures or machine/sample combinations. They are usually used,

Page 21: Instrumental

however, to generate approximate flow curves to mimic complex systems rather than for the detailed investigation of microstructure.

D ~

t s I 1 - D

Figure 1.

(a) (b)

Simple models of viscoelastic behaviour: (a) Maxwell and (b) Voigt elements.

Linear and Non-Linear Viscoelasticity

Classically, the relationship between stress (or) and strain (,/) is determined in the linear strain region, that is, at strains sufficiently small that structure is not disrupted by the local deformation. A system is said to be linear if it can be described by a linear differential equation with constant coefficients. This means an equation relating stress and strain with respect to time of the form, (after Arridge [6]),

Aocr + Al(dcr/dt ) + A2(d2cr/dt2 ) + . . . . . + Am(dmcr/dt TM) = Bo~ / + Bl(dy/dt ) + B2(d~/dt2 ) + . . . . . + Bn(dr~/dt n) (1)

For the simple systems already mentioned, this is greatly reduced to give:

Aocr = BoY Aocr = Bl(d),/dt ) Aocr + Al(dcr/dt ) = Bl(dy/dt ) Aocr = Bo~, + Bl(dy/dt )

(Hooke's law; G = Bo/Ao) (2) (Newton's law; 11 = B1/Ao) (3) (Maxwell element) (4) (Voigt element) (5)

Page 22: Instrumental

euU

CP~

a

w

Time

. m

k , 4 ~

I

X Y Time

Figure 2. Resultant strain due to stress imposed at X and removed at Y, for (a) Maxwell model (b) Voigt model.

Page 23: Instrumental

If, for instance, strains or rates of strain become excessive for a given material, equation (1) is no longer obeyed and the behaviour is said to be non-linear. This is exemplified by, for instance, flow in metals above the elastic limit or non-Newtonian flow (shear thinning) of biopolymer solutions at high shear-rates. In the modem food industry, the non-linear (breakdown and recovery) properties of a component are often its most important feature. Numerous applications exist where a food system must remain thick, or even suspend particles, under low or zero shear conditions but be capable of flow when pumped during processing or subjected to high shear stresses and strains by the consumer. In particular, the modem trend to replace conventional dairy products with low-fat biopolymer-based analogues requires careful matching of both linear and non-linear properties together with other considerations such as temperature dependency. It is not intended to delve more deeply into this subject here, but it is essential that linear measurements, where meaningful molecular interpretation can be employed, should be distinguishable from the non-linear regime, where, with the exception of the simplest structural types, 'phenomenological' modelling of particular samples is still the more accepted, common practice.

Types of Deformation

The two forms of deformation usually applied to hydrated food biopolymer systems are uniaxial compression (or tension) and shear. If the sample is sufficiently rigid (self-supporting), simple compression testing can be used. Here, a sample of well- defined size and shape is confined between parallel surfaces that can be made to approach one another under controlled conditions, the relative displacement and resulting stress in the sample being monitored. For infinitesimal strains in compression or tension (Figure 3a), during, for instance, a stress-relaxation experiment, the time- dependent stress t~(t) = F(t)/A and the strain (~,) [fractional deformation] is A1/L giving a time-dependent elongational (Young' s) modulus E(t) = [F(t)L]/[AAI].

Figure 3. Types of deformation commonly used to determine moduli of food materials. Uniaxial tension/compression (a), and shear (b).

Page 24: Instrumental

Several problems are inherent in such measurements. Under normal conditions, samples need to be relatively 'stiff' and at higher deformations, true strain and cross- sectional area are difficult to determine. The level of lubrication between instrtunent and sample surfaces also becomes critically important under such conditions. For these reasons, measurements are usually confined to the small-deformation regime or, commonly in food-development applications, to produce characteristic force/deformation (or approximate stress/strain) curves for comparison with target products or optimisation of process conditions. Since large volumes of sample are usually available, by averaging several replicates representative 'breakdown and flow' properties can be determined under the compressive strain conditions which may be applicable to end-use.

Of more general use in the investigation of food biopolymer systems is shear deformation, illustrated in elemental form in Figure 3b. Here, the shear stress is again or(t) = F(t)/A but the shear strain ~, is equal to tan(0) (~, 0 for small 0). Because the sample is confined between two surfaces a fixed distance apart with strain usually being imposed by their relative angular displacement about a common axis, systems from simple solutions to strong gels can be analysed, and, up to moderate strain and rate-of-strain, sample dimensions remain well defined. An added advantage of such a geometry is that the exposed sample surface is small, allowing effective sealing against water-loss during long-time measurement or experiments involving prolonged heating using a suitable medium such as silicone fluid or liquid paraffin.

For the special case of a perfectly elastic body, or a viscoelastic solid at long experimental times whereby all time-dependent processes have relaxed away and an equilibrium modulus is measured (i.e. for a real system, the modulus of the underlying gel network is measured, or for the Voigt model, equilibrium extension of the spring is reached), a simple relationship between these moduli exists. The equilibrium Young's modulus, E e and equilibrium shear modulus G e are related by the equation E e = 2Ge(1 +~t), where la is Poisson's ratio which is the ratio of lateral contraction to axial strain in the extensional experiment. The maximum value possible for ~t is 0.5 and for some soft-solid systems, this is almost achieved giving E e ~ 3G e

Small-Deformation Oscillatory Measurements

In the transient experiments so far described, the measured parameter is a result of both the elastic and viscous sample properties. Although all necessary information about these is contained within, for example, a creep curve, a method whereby the elastic and viscous components can be determined directly at a given experimental time (or corresponding frequency) is obviously desirable. Also, it is often necessary to obtain information about the ~iscoelastic properties of a sample system as it undergoes structural change, e.g. gelation. Here, a method is required such that measurements can be made in periods shorter than the process to be monitored without affecting the natural mechanisms involved.

Page 25: Instrumental

If a sample is subjected m a time-dependent strain-wave of the form

)' = "/o sin o)t (6)

where ,/is the time-dependent strain, "/o is the maximum strain amplitude and o) is the angular frequency (Figure 4a), then the resulting shear-stress wave will also be a sine- wave but differing in amplitude and phase, i.e.

o = o 0 sin(cot + ~) (7)

where cr is the time-dependent stress, cr o is the maximum stress amplitude and 6 is the phase angle difference between the two waves.

Considering a purely elastic sample, the instantaneous stress will be proportional m the corresponding strain and the strain and stress waves will therefore be in phase with each other, as shown in Figure 4b. For a viscous system, however, the stress will be proportional to the strain-rate at any given time and thus the maximum stress will occur when the slope of the strain wave is a maximum, i.e. at the zero cross-over points. This results in a phase-shift of n/2 radians (Figure 4c). A viscoelastic sample will therefore produce a stress-wave whose amplitude is proportional to the strain amplitude, but having contributions from both the in-phase and out-of-phase components (Figure 4d). Assigning separate symbols m the elastic and viscous moduli, the stress wave function may be written in the form:

cr = "/o(G'sino3t + G"coso3t) (8)

where G' is the in-phase, storage modulus and G" is the out-of-phase, loss modulus.

Re-writing equation (7) as

cr = Cro(COS~Ssintot + sin5coso)t) (9)

by comparison with (8), it is clear that

and G' = ((rdvo)COS5 (1 o) G" = ((~o/Yo)sin~5 (11 )

From these two basic parameters, others may usefully be derived.

G"/G' = tan5 (12)

Tan& the loss tangent, is useful in detecting structural changes particularly during broad gelation or melting processes where large variation in the absolute values of both G' and G" may conceal subtle effects indicative, for instance, of more than one underlying process. Also, from (10) and (11)

therefore (G') 2 + (G") 2 = (t~o/Yo)2(sin25 + cos2~i) cr0/y 0 = [(G') 2 + (G")2] v' = [G* I

(13) (14)

Page 26: Instrumental

I l l l l l l l i t a

l i l l

i

I I I [ I I

v

\ ', / : \ / :: I I

',\', : I \ i \~ i II \ I

: ~ 7 : \ / I !

I I I I I i 1 I , p r -

O ~:/2 ~: 3~:/2 2~: O)t

b

Drive s t ra in

Elastic response

Viscous

response

d Viscoelastic response

Figure 4. Resultant stresses due to a smusoidal drive strain (a) for elastic (b), viscous (c), and viscoelastic (d) materials.

Page 27: Instrumental

10

]G'I, the complex modulus, is therefore the simple ratio of stress amplitude to strain amplitude without regard for the type of mechanism involved, storage or loss.

As for the dynamic moduli, dynamic viscosity components can be defined. The real dynamic viscosity rl' is the ratio of stress in-phase with the strain-rate to that strain- rate and the imaginary dynamic viscosity, rl", is the ratio of stress n/2 out-of-phase with the strain-rate divided by the strain-rate. The rate-of-strain is the first derivative of the strain function with respect to time, thus

d~,/dt = ~,0o~coso~t (15)

i.e., a sine-wave of amplitude ,/0co phase-shifted by n/2 with respect to the strain wave. By the same procedure used to obtain equations (1 O) and (11 )

rl '= (Cro/~'oO~)sin8 = G"&o 11"= (Cro/~,0~o)cos5 = G'/o~

(16) (17)

Although rl' is sometimes compared with the steady-shear viscosity rl, it is probably at least equally valid to use a viscosity obtained from the total resultant stress cr 0.

i.e. Cro/~,0o~ = I G* l/co = II1" I (18)

where [r I* [ is termed the complex dynamic viscosity.

Using oscillatory methods, it is therefore possible to extract the elastic and viscous contributions to the mechanical behaviour of a sample system as the structure changes with experimental time, temperature, strain, etc. By 'sweeping' the imposed frequency, mechanical spectra of, for instance, G'(o~) and G"(co) are obtained from which the time (frequency) dependent nature of the sample can be analysed to identify the most important structural features.

Rheologicai Characterisation of Biopolymer Systems Using Oscillatory Techniques.

The mechanical spectrum of a material (e.g. the storage modulus (G'), loss modulus (G"), and dynamic viscosity (11") plotted as a function of angular frequency (co)) gives an accurate indication of the structural type. Typical examples of the four general classes of behaviour for low to medium concentrations of polymer over an unspecified frequency range are shown in Figure 5.

In the case of a dilute solution, (Figure 5a), even high molecular weight chains can be considered to be isolated so that their principal effect is to perturb the solvent flow. For the random coil chains usually encountered in food polymers, all possible rearrangements can take place within the period of the imposed oscillation [7]. As frequency increases, the viscosity remains essentially constant and the dominating loss component G" (= rl'cO) increases in proportion to frequency although an elastic contribution (G' oc o32) also begins to come into effect. Mechanical spectra of these

Page 28: Instrumental

11

relatively simple dilute systems were the first to be successfully modelled on a molecular basis using bead-spring arrangements for flexible chains [8,9].

As polymer concentration and/or molecular weight increase, the volurnes of influence of individual chains begin to encroach on each other, (domain overlap), followed by more direct chain-chain interaction (coil overlap) [7]. Above this 'coil overlap concentration' c*, the system is said to be semi-dilute. With further increase in concentration, polymer-polymer interaction becomes progressively more dominant until essentially uniform polymer density is achieved throughout the system. Through this concentration regime, polymer chains begin to interpenetrate and a new mechanism known as entanglement coupling dominates where the rheological properties are dictated by molecular weight rather than the hydrodynamic volume of individual coils. In the dilute region, and using frequencies applicable to standard laboratory rheometers, only Newtonian behaviour can be observed. Moving through the semi-dilute region, however, the frequency and shear-rate to which rl*(co) and rl(7) remain constant become progressively less as 'shear-thinning' behaviour is encountered at the higher frequencies and shear-rates. In this region, both G' and G" become much less dependent on frequency and, when true entanglement coupling exists, G' exceeds G" (Figure 5b). At higher frequency still, the moduli are almost independent of frequency and because this behaviour, combined with G ' > G", is similar to that exhibited by rubber-like materials, this is called the 'rubbery' plateau region; the low-frequency Newtonian region being the terminal zone for this type of material.

The transition from Newtonian to shear-thinning behaviour is dictated by a terminal relaxation process, characterised by the longest relaxation time associated with the natural motion of the polymer chain or a polymer-polymer disentanglement time. In the latter case, the disentanglement-re-entanglement process can occur easily within the timescale of imposed motion provided the frequency is sufficiently low and thus the overall entanglement density remains constant. At higher frequencies and shear- rates, this is no longer possible and re-entanglement diminishes giving rise to a progressive reduction of entanglement density and consequent lower dependency of transmitted stress on frequency or shear-rate. For dilute solutions, measurements are strain-independent and the same is substantially true of this region where mechanical properties are dictated by a single, or narrow band, of relaxation times, depending on degree of polydispersity. This gives rise to the well known empirical law that the value of rl*(o3) is equivalent to that of rl(dl,/dt) when o3 and d~t/dt are numerically equal (i.e. the Cox-Merz Rule [10]. Because materials possessing shear-thinning properties are of commercial importance, numerous models have been developed to emulate their Newtonian to power-law-dependent theology such as those of Cross [11 ] and Morris [12]. Advanced theories based on molecular considerations (i.e. chains topologically constrained by nearest neighbours) are those of Graessley, described by entanglement loci with weighted frictional coefficients [13], and de Gennes and Doi and Edwards, reptation and confining tubes [14,15].

In the systems described so far, only mechanical interaction between the constituent polymers has been considered. Although some weak, non-covalent bonding (hyperentanglements) is detected in aqueous food biopolymer systems such as galactomannans [16,17], the effect on the 'entanglement spectrum' of Figure 5b is

Page 29: Instrumental

12

minimal. If more permanent bonding is introduced, the system can maintain elastic properties to the longest times (lowest frequencies) normally observed and the classes of mechanical response known as gels and 'weak-gels' are obtained.

The gelling of biopolymers has been a traditional method of structuring foods for many centuries. Heat denaturation of animal protein to form a solid (gelation of ovalbumin when boiling an egg) and cold setting of plant polysaccharide in the presence of high levels of sugar (pectin gelation in jam making) are obvious examples. Extracted proteins and polysaccharides form the basic structuring agents m commercial fabricated foods and a vast body of literature concerning gelation mechanisms in general and mechanical properties of specific aqueous biopolymer gels has therefore been established. This important topic is beyond the scope of the present brief overview but those interested should refer to the excellent review of the subject by Clark and Ross-Murphy [ 18].

Figure 5c shows the mechanical specmma of a 'true' gel with G'(o~) substantially above G"(o~), both being almost independent of frequency so that rl*(to) decreases with a slope of-1 on the double logarithmic plot. If the bonding is truly permanent, a finite elastic modulus (equilibrium modulus G'e) could theoretically be measured at infimtely long time. For many biopolymer gels, the bonding is likely to be somewhat more transient in nature and the plateau modulus observed at the moderate times of normal experimental procedures is referred to as the 'pseudo-equilibrium modulus'. Many gels, although of relatively high modulus, can withstand large strains (often in excess of 100%) before rupture.

The class of materials known as 'weak gels' are of particular importance to the modem food industry. As shown in Figure 5d, the spectrum is similar to that of a normal gel with, perhaps, some frequency dependence and a higher average value for tan& The major difference between the two types is, however, that these systems exhibit much greater strain (or corresponding stress) dependence. Food types which are solid-like when undisturbed but can be easily poured or spread may be included in this category. A consequence of the rapid (but usually smooth and coherent) strain- induced breakdown of these materials is that superposition of rl*(09) and rl(~ ) no longer applies, strong power-law dependency being observed but with the steady-shear viscosity considerably below the dynamic viscosity. The archetypal 'weak-gel' food biopolymer is the bacterial polysaccharide xanthan composed of weakly associated extended chains. Similar properties can be generated by specialized manufacturing techniques to reproduce a heterogeneous structure composed of strong domains linked again by narrow regions of weak bonding in which strain is concentrated to produce the required breakdown characteristics. The time necessary for complete recovery of the undisturbed structure in such systems has been observed to extend to several hours [19].

It is clear from the spectra shown in Figure 5 that a relationship exists between time- dependent properties and the level of internal structure. Increasing concentration and molecular weight or decreasing temperature have often been used to effectively shift measurable spectra to higher frequencies. The entanglement system in the range of frequencies normally accessible shows behaviour typical of the terminal region at low frequencies through a transition zone to a rubber-like plateau at moderately high

Page 30: Instrumental

13

a b G'

G " 4 1 . - I t -

_ _ _ _ . . . . . . .

o o rl*

_ 1 ~ _ _ _ _ _ - �9 , �9 I _ _ _ _ _

0 O- log m (rad s "1) log m (rad s -l)

4t-

e~0 O

C

. . . . . . . . . . . . . . . ! " l ( -

e ~ 0 o _ . . _ G l !

rl*

d

I - _ . . . . . . . . . . . . . . | . . . . . . _ L , ~ - . . . .

0 o log Co (rad s -1) log 03 (rad s "l)

G !

G t !

rl*

Figure 5. The four principal categories of mechanical spectra: (a) Dilute solution, (b) entangled solution, (c) strong gel and (d) 'weak gel'.

Page 31: Instrumental

14

frequency. If this range could be extended to access even shorter times, a 'glassy' region would be reached where only local chain motion is possible within the experimental timescale. For permanently cross-linked gels, rubber-like terminal behaviour will be observed but a similar glassy region is still accessible. Later, glassy behaviour and 'frequency shifting' (time-temperature superposition) techniques as applied to food biopolymers will be addressed in more detail.

From the above, it is clear that rheology is a powerful technique to assist in the study of food biopolymer materials as well as being indispensable in the areas of product development and quality control. Long-time creep measurements, for instance, are particularly informative with regard to permanency of structural bonding [20], and oscillatory frequency and strain sweeps, perhaps in combination with microscopy, are routinely used to indicate underlying microstructure. Investigation into the gelling mechanisms of biopolymers is greatly facilitated by monitoring small-deformation viscoelastic properties during temperature induced gelation or melting, particularly when results are compared with those from other physical techniques such as differential scanning calorimetry (DSC) and optical rotation (OR). Temperature sweeps are also extremely useful in determining, for instance, which component forms the continuous phase in two component, or multi-component, systems.

MODERN RHEOMETER TYPES

Modem computer controlled rheometers intended for shear measurements are now relatively commonplace in food research and development. According to their mode of operation, two distinct types are produced; controlled strain and controlled stress. In the former type, a powerful motor is used to impose a pre-determined strain, or strain-rate on the sample via one side of the measuring geometry and the transmitted stress is detected at the opposing sample fixture by a low-compliance (or active zero-compliance) transducer. Controlled stress instruments consist of a 'drag-cup' rotor, optical strain detector and upper sample geometry on a common shaft supported in an air-bearing, the housing of which also contains the motor windings. With the sample confined between the upper geometry and a lower stationary fixture, the required sample stress can be imposed with negligible losses in the air-bearing, and the resulting strain measured by the angular displacement of the single moving part. By virtue of their relatively simple construction and the fact that stress is easily controlled by the current passing through the motor coils, these latter instruments tend to be less expensive than the strain controlled variety in which more elaborate engineering is necessary to guarantee accurate imposed strains over a wide dynamic range. It is, however, desirable to be able to control the strain during, for instance, gel-cure experiments and, provided measurement in the linear region can be maintained, it is possible to operate stress-controlled instruments in a fashion which closely approximates to strain control for dynamic oscillatory experiments.

Page 32: Instrumental

15

Measurement Geometries

Three standard geometries are used to contain samples in a well-defined shape during shear measurements: cone-and plate, parallel plate and concentric cylinder (Figure 6, below and overleaf). The cone-and-plate geometry (Figure 6a) is theoretically ideal in that the strain, or rate of strain, is constant over the whole working surface. Since a full cone would touch the plate, it is trtmcated but in commercial instruments, this is slight to minimise strain error. Since small dimensional changes in the rheometer could still cause contact, cone-and-plate geometries are not considered suitable for temperature sweep experiments. It is, however, the best option for isothermal measurements on both linear and non-linear systems.

Figure 6a. Cone-and-plate geometry.

In the parallel plate system (Figure 6b), the problem of expansion is removed but the sample now experiences a strain varying from a maximum at the periphery down to zero at the centre. This is, however, a good general purpose geometry for the examination of strain-independent systems over a wide temperature range. An added advantage is that, within reasonable limits, the gap can be varied to effectively shift the dynamic strain/strain-rate range of the rheometer. For instance, if a wide gap can be tolerated, the strain resolution will be improved allowing more highly strain- dependent or higher modulus materials to be measured.

03

Figure 6b. Parallel plate geometry.

Page 33: Instrumental

16

The concentric cylinder geometry (Figure 6c) is often used in simple viscometers and for dilute solution work since the sample is contained and the torque to sample-volume ratio can be high. The strain-rate is not constant across the sample, being a maximum at the inner surface, but the gap is usually kept small (<= 0.1 of the outer cylinder radius) to minimise errors. Since measurement is made in the body of the sample with a wide gap at the upper surface, 'skin' effects are small and a thick layer of barrier liquid can be flooded over the surface to prevent water loss making this geometry ideal for dynamic and creep experiments over long time periods, particularly at elevated temperatures.

Figure 6c. Concentric cylinder geometry.

Practical Considerations

Before moving on to examine specific sample types in more detail, it is perhaps desirable to highlight potential problems which may arise in the day-to-day rheological evaluation of food component materials. Advances in applied microelectronics have meant that the time-consuming manual procedures prevalent some 20 years ago, often involving equipment developed 'in-house', have been superseded by the introduction of computer controlled commercial insmmaents with complete integral data processing capable of running linked, consecutive experiments. Given the impressive, automatic nature of these insmnnents, it is sometimes easy to forget their limitations, which, together with the structural complexity of some sample materials, can lead to misinterpretation of results.

Page 34: Instrumental

17

With regard to the instrument itself, the dynamic range for both stress and strain measurement is the important requirement. Sample moduli may undergo changes of several orders of magnitude during, for instance, gelation or melting during temperature sweeps. Although the range can be shifted by changing geometry or torsion bars when appropriate, this may mean that more than one set of experiments is necessary for complete characterisation of a given sample. Taking as an example a standard stress-controlled rheometer, measurement of steady shear viscosity over a wide range of shear-rate and sample viscosity presents no great problems. The lower limit of viscosity and shear-rate is defined by the minimum useful stress, which is itself ultimately dictated by the quality of the air bearing. The upper shear-rate for highly viscous samples obviously depends on the maximum stress available but, since imposing a stress and measuring strain or rate-of-strain is simply a creep test, low shear-rate measurements are possible on even the highest viscosity samples likely to be encountered, provided enough time is available.

Small-deformation oscillatory experiments represent a more rigorous test of machine performance. Here, two sinusoidal signals must be compared in terms of amplitude and phase and provided at least one of these is of reasonable size, results are usually satisfactory. Difficulties do, however arise if very small signals need to be correlated, as may be the case for some low-modulus, but highly strain-dependent food materials. Working below the designed range of the instrument in this manner sometimes results m an 'offset' modulus which can be falsely assigned to the sample. Although automatic corrections for moment of inertia and, where appropriate, compliance of the insmunent, are incorporated in modem machines, these still limit the high-frequency performance and upper limit of sample modulus respectively. In a driven mechanical system, the forces due to elasticity and inertia are in anti-phase, the inertial force being proportional to co 2. At high frequency, therefore, the elastic component of a low- modulus sample may be dominated by inertial forces (measured as negative G') such that it is reduced to the error-band of in-phase resolution. Indeed, when making high frequency measurements of very weak system, where the normal 'narrow-gap' conditions (stress waves traverse the sample) begin to be superseded by surface loading or 'infinite sea' conditions (stress waves penetrate only the upper layer of sample), the first, approximate correction to be made is for loss of sample inertia, the dominant effect. With regard to very high modulus systems such as glasses, two factors come into play. Unless the rheometer is designed for such samples, overall machine compliance may become significant compared to that of the sample and, if only limited maximum stress is available, the strain generated may be too small for accurate measurement. The obvious ploy of using a geometry of small working surface area and large gap may produce measurable strains but correction for insmmaent compliance is also a likely requirement.

Rheology is unusual among the physical methods used in the modem laboratory in that sample handling represents a major experimental event. Loading the sample probably imposes far greater stresses and strains than will have to be endured during the subsequent experiments. Whilst this presents no problem for simple fluids or gels that can be set from the liquid state, more structured materials with long memories such as weak gels require small-deformation time-sweeps to ensure complete recovery to the undisturbed state before further testing. Trapped air can also be a problem in such systems during temperature sweeps, as its expulsion at elevated temperature can

Page 35: Instrumental

18

lead to water loss and 'skin' formation at the edges of parallel plate geometries. Sample slippage is also a potential problem particularly for some biopolymer gels such as agarose, carrageenan and gellan which set very quickly and are susceptible to syneresis and perhaps shrinkage. Slippage is not necessarily easy to detect and, indeed, analysis using linear models indicates that provided very thin, viscous interfacial layers are involved, the measured elastic modulus will not be greatly affected. However, these conditions, particularly linearity, cannot be guaranteed and an observed collapse of G' accompanied by a high value of tan 5 usually indicates a problem. Using small strains and slow temperature scan rates can help but it may be necessary to resort to special non-slip geometries in such cases [21,22].

To summarise this section, it should be remembered that both the rheometer and the sample are being measured in a rheological experiment. It is desirable to ascertain the range, sensitivity and phase resolution of the instrument using standard materials, the results being a useful check on future performance. As far as the samples are concerned, measurement of complex systems should be supplemented by as much independent structural information as possible, the minimum requirement being visual assessment to highlight any simple problems which may not be obvious from the generated data. Although all the considerations mentioned above are fairly obvious and will be well known to those routinely involved in the rheological investigation of food biopolymers, there may be some information which will prove useful to those about to embark on such work or who have limited experience of practical measurements.

RHEOLOGY OF SOLUTIONS UNDER STEADY SHEAR CONDITIONS

Dilute Solutions

A particularly convenient and useful experimental parameter in studies of dilute solutions is the intrinsic viscosity [q], a measure of the volume occupied by the individual polymer molecules in isolation, which is directly related to molecular weight (M) and is therefore widely used in routine characterisation of polymer batches (Mark-Houwink equation):

[11] = K M ix (19)

where K and ot are constants whose values depend on the shape of the polymer, the solvent used and the temperature of measurement. Typical values of ot for random coils are 0.5 - 0.8, and for rigid rods 1.5 - 1.8 [23].

Intrinsic viscosity is defined by the standard equations:

rlrel = rl/rls (20) rlsp = (11- rls)/rls = rlrel- 1 (21) [11] = lim (risp/C) (22)

c----~0

Page 36: Instrumental

19

where ~ and Vls denote the viscosities of the solution and solvent, respectively, and qrel and TisD are, respectively the dimensionless parameters of relative viscosity and specifi6viscosity. Experimental values of Visp for extrapolation to intrinsic viscosity at infinite dilution (equation (22)) should be in the range 0.2 to 1.0.

Treating now molecules as particles widely separated, the Einstein relationship for laminar flow can be derived [24]:

rl = rls (1 + kl~ ) (23)

where r is the phase volume of the disperse phase and k 1 takes the value of 2.5 for spheres. From equations (21) and (23) rlsp can be expressed as a function of phase volume:

rlsp = klr (24)

Combination of equations (22) and (24) for infinite dilution gives the identity:

klr = rlsp = [rl]c (25)

At higher concentrations, where the increase in viscosity is not directly proportional to the mass of the disperse phase, the Einstein relation is extended by including higher order terms in equation (24):

rlsp = k1r + k2t~ 2 + k3t~ 3 + k4~ 4 + ... (26)

Experimentally, a linear intrinsic viscosity-concentration relationship is observed for specific viscosities up to about 1 and its numerical form is obtained by keeping terms up to quadratic in equation (26) and substituting 0 from equation (25):

where k' = k2/kl 2

rlsp/C = [rl] + k' [ri]2c (27)

This is the Huggins equation and the extrapolation to give intrinsic viscosity is obtained from a plot of rlsp/C v s c [25]. An alternative extrapolation is given by the equation of Kraemer [26]"

ln(rlrel)/C = [r I ] + k" [rl ]2c (28)

It can be readily shown that k" = k' - 0.5, and thus equations (27) and (28) may be combined to give an expression that allows intrinsic viscosity to be estimated from measurements at a single concentration (the single point method) [27]:

[ri] = [2(rlsp- lnrlrel)]�89 (29)

The values obtained by this method may, however, also be plotted as a function of concentration, along with the corresponding values from the Huggins and Kraemer treatments. In practice these extrapolations may not be strictly linear, but using all of them, intrinsic viscosities can be well bracketed (Figure 7).

Page 37: Instrumental

20

[hi ---------liD-

Huggins - J

Single point-_ J [2(TIs p - In T] rel)]l/2/C

, , ,

ln(TI rel)/C

Figure 7.

Concentration The three extrapolations to zero concentration in the determination of intrinsic viscosity.

Effect of Entanglement

Moving now from the case of very dilute solutions, where the intention was to acquire information about the volume occupied by individual molecules, up to the real range of practical viscosity behaviour (rlsp > 1), the Huggins and the other associated extrapolations become irrelevant because higher order powers such as those in equation (8) start to be significant. With further increase in concentration, viscosity begins to show appreciable dependence on shear rate (~). At low shear rates viscosity remains constant at a fixed, maximum value (the 'zero shear' viscosity, 11o), but at higher values 'shear thinning' is observed (Figure 8). Taking the maximum 'zero shear' value, it has been observed empirically that for a wide range of 'random coil' polysaccharides the log of rlsp varies approximately linearly with the log of concentration over the viscosity range 1 < rlsp < 10, with a slope of about 1.4 [28].

This is illustrated in Figure 9 for the disordered form of the capsular polysaccharide from Rhizobium trifolii (CPS), with the zero shear specific viscosity at the critical concentration (c = c*) being close to 10 [29]. At higher values of rlsp, however, the concentration dependence changes to a slope of about 3.3 and solutmns are termed semidilute. At the inflection point, the 'coil overlap parameter' (c*[rl] from equation 25) has been found to have a value between 3 and 4 regardless of polymer primary structure and molecular weight [28]. At even higher concentrations, individual coils will form an entangled network whose relaxation time will be heavily governed by the polymer molecular weight.

Page 38: Instrumental

21

@ m

T 1 --1"1o

11 - 0.5

I I I

log "~ (l/s)

Figure 8. Shear-rate dependence of viscosity for a typical concentrated biopolymer solution.

3.0

2.0

log rls p 1.0

Figure 9.

0.0

-1.0

slope = 9.3

s l o p e - 3.3

s l o p e - 2.2 I I I I I Ic[rl] = 3 6 J I

I I t i i I i 1 I i ! i

slope = 1.4

-1.0 -0.5 0.0 0.5 1.0 1.5 log clrll

The variation of 'zero-shear' specific viscosity with degree of space-occupancy for CPS in the disordered form at 55~ (D), and for levan at 20~ (m), from [29] with permission.

Page 39: Instrumental

22

The change in concentration-dependence of solution viscosity during the transition from a dilute solution of independently moving coils to an entangled network can be rationalised as follows. At concentrations below the onset of coil overlap and entanglement (c < c*), the main effect of the polysaccharide coils is to perturb the flow of the solvent by tumbling around and setting up 'countercurrents', with mutual interference of countercurrents from adjacent chains giving a somewhat more than proportional increase in viscosity with increasing concentration. At concentrations above c*, however, where flow requires chains to move through the entangled network of neighbouring coils, the restriction of mobility increases steeply with increasing network density, giving rise to the higher concentration-dependence of viscosity.

Shear thinning behaviour in polysaccharide solutions can be rationalised as follows: At concentrations below c*, shear thinning is minimal (typically less than 30% over several decades of shear rate), and can be attributed to elongation of individual coils in the direction of flow at high enough ~;. The 'Newtonian plateau' observed (Figure 8) for entangled coils (c > c*) at low shear rates corresponds to a dynamic equilibrium between forced disentanglement (to allow the solution to flow), and re-entanglement with new partners. At higher values of ~, where the rate of disentanglement exceeds the rate at which new entanglements can form, the overall crosslink-density of the network is reduced, with consequent reduction in viscosity (often by several orders of magnitude). The form of the shear-thinning for entangled polysaccharide coils can be matched, with reasonable precision [28], by the equation:

rl = 1] ~ . ( r l / ~ l/z)0.76 1,1 ~ 0.76 (30)

where ~ ~/~ is the shear rate required to reduce rl to rio/2. Thus the two parameters rio and 3; ,/2 which, in conjunction with equation (30), completely characterise the flow behaviour of a random coil solution can be determined from a linear plot of

vs. rl~ 0.76. Figure 10 shows linearised shear-thinning plots derived in this way for some typical random coil polysaccharide solutions [12].

2o r

15

10

Figure 10.

0 0 20 40 60 80 1 O0

n ~ 0.76

Shear-thinning plots for locust-bean gum (i), alginate (o), pectin (A), and lambda carrageenan (o), from [12] with permission.

Page 40: Instrumental

23

Recently the concentration dependence of zero shear viscosity was monitored for bacterial levan [29], an extensively branched polysaccharide with a compact, spheroidal shape ([rl] = 0.17 dl/g). This time the discontinuity in the rlsp v s . c[rl] profile was first indicated at much lower values of the coil overlap parameter (about 0.75), a threshold which indicates the end of the dilute regime (Figure 9). Similarly, a value of C[rl] about 1 has been proposed to signify the concentration (c = c*) where the swept-out volume occupied by spherical coils becomes equal to the total volume (~ = 1). The sharp rise in viscosity of levan at high concentrations (slope of 9.3 at c >_ 19%) has been rationalised qualitatively by the reptation theory of de Gennes [14]. In this model a highly branched macromolecule is confined within a hypothetical tube whose domain is determined by the branching points of the main backbone. Long range movement along the tube is only allowed when a branch disentangles from the sites of neighbouring chains thus making obvious the additional constraints to flow for the heavily branched levan molecules as opposed to linear polysaccharides.

BINARY BIOPOLYMER MIXTURES

Two gelling biopolymers in the same system can create three general types of network structure, namely:

a) b) c)

Interpenetrating networks Coupled networks and Phase-separated networks

as illustrated in Figure 11 below (from [30] with permission).

. J a b

Figure 11.

C

The three possible network topologies for binary gelling systems.

Page 41: Instrumental

24

a) Interpenetrating Networks

These represent the simplest situation, rarely encountered in mixed biopolymer gels, where the two components gel separately forming two independent network structures. Both networks span the entire system, interpenetrating one another, but interaction is solely topological (Figure 11 a). If each polymer forms a homogeneous network across the whole of the single phase, and if the like segments possess identical properties in all directions, then the modulus of the composite has been observed to be related to the moduli of the two component networks by a logarithmic mixing rule [31 ].

Log M = ~x log M x + t~y log My (31)

where ~x and #v are the phase volumes of polymers X and Y, and M (composite), M x and My can be hither the Young's or the shear modulus.

Although the formation of interpenetrating networks is simple and reasonably well understood, two dissimilar polymers present in the same system may not necessarily form two separate interpenetrating networks for reasons of thermodynamic incompatibility discussed in the Section on phase separated networks. One way of ensuring bicontinuity for experimental studies is, as suggested by Morris [30], to introduce a second polymer into the pores of a pre-existing network, and then to alter conditions in such a way that this second species forms its own network without disruption of the original gel. The problem of slow diffusion of a polymer solution into a gel can be tackled by using smaller globular proteins as the diffusing species. Dispersion may be enhanced with suitable alterations of the network charge or even by the use of external electric fields. An alternative would be to prepare a xerogel and then swell this gel in the protein solution. A final requirement is the thermal irreversibility of the pre-existing polymer network in order to allow for the heat-set process of the protein.

b) Coupled Networks

This kind of interaction involves a direct association between two different polymers to form a single network (Figure 11 b). Three different types of intermolecular binding may then arise:

1)) Covalent linkages Ionic interactions

iiQ Co-operative junctions

Chemical cross-linking between different chains offers a direct way of forming a gel network The main characteristic of a system held by covalent bonds is its thermostability and this can be achieved even at relatively low crosslink densities. It can withstand heating, but loses its gel-like character through disruption of chemical bonds in a way reminiscent of the oxidative degradation of the disulphide bonds of rubber. Rheologically, the most notable feature of covalently cross-linked gels is the permanency of the network formed, which is typically greater than that observed in physically-crosslinked gels [32,33]. Effectively, covalent crosslinks have infinite relaxation time.

Page 42: Instrumental

25

One reasonably well-understood interaction of this type involves the formation of amide bonds between the propylene glycol esters of alginate (PGA) and uncharged amino groups of gelatin [34]. The crosslinking reaction proceeds smoothly when aqueous solutions of the ester and protein are mixed under mildly alkaline conditions (z pH 9.6) giving gels that are stable to above 100~ Evidence for the chemical nature of the crosslink is not direct, but dye binding experiments, the binding of trinitrosulphonic acid, and studies of the formal titration show that lysine groups are involved but that only about one in six is utilised. Gel strength increases with increasing mannuronate content in the alginate [35], indicating that ester groups attached to the extended polymannuronate ribbons are more accessible than those in the highly buckled polyguluronate sequences.

Direct interactions can also occur between biopolymers of opposite net charge, by formation of an insoluble coacervate. Complex coacervation between, for example, gum arabic and gelatin has extensive practical use in microencapsulation [36]. Coacervation with anionic polysaccharides has also been proposed as a method for recovery of waste protein from abattoir effluent or whey [37]. Alginate is a particularly attractive choice for the polysaccharide component, since its calcium- induced gelation may be used to structure the recovered protein after solubilisation of the coacervate by raising the pH to above the isoelectric point of the protein. Ionic attraction may also be involved in the highly specific interaction of kappa carrageenan with kappa casein, to give a weak gel network of practical importance in, for example, preventing sedimentation of cocoa particles in chocolate milk desserts [38].

Finally, it has been suggested that in some systems the interactions of unlike polysaccharides may involve formation of specific co-operative junction zones analogous to those in single-component gel systems, such as carrageenans, but with the participating chains being heterotypic rather than homotypic. The mixed gels formed between alginate and pectin under acid conditions are believed to involve junctions of this type [39]. Gel strength increases with the methyl ester content of the pectin and with the polyguluronate content of the alginate. The requirement for low pH can be explained in terms of protonation of carboxyl groups causing reduction of electrostatic repulsion between the chains, with a high degree of esterification in the pectin component having a similar effect. The specific involvement of poly-L-guluronate can be rationalised in terms of its near mirror-image relationship to the poly-D-galacturonate backbone of pectin allowing stereoregular heterotypic junctions to be formed [40]. The most compelling lines of evidence for such mixed junctions are the development of maximum gel strength at stoichiometric equivalence of poly-L-guluronate and esterified poly-D-galacturonate and the circular dichroism changes accompanying gel formation, which are very different from those observed for either polymer in isolation.

Another example of co-operative synergism is between certain galactomannans (notably carob and tara gum) and certain helix-forming polysaccharides (agarose, xanthan, kappa carrageenan). In general the phenomenon is believed to involve unsubstituted regions of the mannan backbone associating with the ordered conformation of the second polymer to create mixed-junction zones [41 ].

Page 43: Instrumental

26

Phase-Separated Networks

When favourable interactions (such as those in polyanion-polycation systems) are absent, thermodynamic incompatibility between chains of dissimilar biopolymers tends to cause each to exclude the other from its polymer domain, so that the effective concentration of both is raised (Figure 11 c). This is true even when the energies of interaction between the chains involved are small (disordered chain segments) in comparison with the much stronger interactions of ordered sequences in polysaccharide gels.

At low concentrations, thermodynamic incompatibility can promote conformational ordering within a single phase, which, for gelling systems, can increase the rate of network formation [42]. At higher concentrations the system may separate into two discrete liquid phases. Generally, phase separation in protein-polysaccharide-water systems occurs only when the total concentration of the macromolecular components exceeds 4% [43], although there are variations from system to system. In the case of carboxyl-containing or sulphated polysaccharides, ionic strength and pH play an important role. For example, proteins and carboxyl-containing polysaccharides phase separate at pH values above the isoelectric point (at any ionic strength) or when the pH is equal to or less than the protein isoelectric point but the ionic strength is greater than ~ 0.25.

Figure 12 presents an example of a typical thermodynamically incompatible protein- polysaccharide system in aqueous solution [44]. The bold line is the binodal or cloud point curve. To the left of the binodal, the system remains in a single phase whereas to

Figure. 12

_

0

••\.•\\• Initial overall \ \ ~ " ' \ ..... \. composition

" \ "-, ""',.

i I I I , I 1 I

0 5 10 15 20

!(:1(%) Phase diagram for casein (C) and sodium alginate (A) in mixed solutions at pH 7.2 and 25~ (o) compositions of co-existing polysaccharide-rich and protein-rich phases, (o) critical point, from [44] with permission.

Page 44: Instrumental

27

the right the system exists in a two-phase liquid state. One of the phases is enriched in polysaccharide and depleted in protein and vice-versa. The faint lines are tie lines joining two points that lie on the binodal and represent the composition of each phase. The initial composition of the mixture is a point on the tie line. All points that lie on the same tie line will eventually separate into phases with the same concentrations (the two terminal points of the tie line) but the relative volumes of the phases will vary. Tie lines finally converge to a critical point and the values of its coordinates provide a measure of the compatibility of the macromolecular components. As shown in Figure 12 the phase diagram is asymmetric (different axis scales) with the polysaccharide usually having a substantially lower final concentration than the protein. This may be explained on the basis of the high volume-occupancy of an expanded polysaccharide coil in comparison with a compact globular protein.

Application of rheological measurements to mixed systems

After gelation, phase separated elastic networks may be regarded as composites whose mechanical properties may be derived from the moduli (G x and Gv) of the two components considered as individual systems present at phase volume frhctions ~x and ~y (where ~x + ~y = 1). The analysis is an approximation, because it is based on binary composites of pure, mutually insoluble, synthetic polymers whose individual rheological properties are independent of the macroscopic amounts present [45]. According to the most simple model, by assuming extreme cases in the distribution of strain and stress within the composite, two equations can be derived:

Gc = ~)x Gx + (l)yGy (3 2)

l/Gc = 4)x/Gx + 4)y/Gy (33)

where G c is the shear modulus of the composite. Equation (32) applies to isostrain conditions, where the continuous phase is more rigid than the dispersed phase so that the strain is approximately uniform throughout the material (upper bound), whereas equation (33) refers to isostress conditions, where the supporting phase is substantially weaker than the discontinuous phase hence the stress may be regarded as constant in both phases (lower bound).

By combining two simple viscoelastic models (e.g. Voigt elements in parallel and series) in proportion to their phase volumes, it is a simple matter to predict overall viscoelastic properties. In the original work of Takayanagi [45], such a model was checked by performing dynamic extensional measurements on samples composed of two layers of different synthetic polymers, the strain being imposed either parallel or perpendicular to their common sides. For true dispersed composites, it was found that a three element model was necessary to accurately emulate both E' and E" over the wide temperature range employed.

In the case of water-based biopolymer composites, where structural complexity is likely to make such a sophisticated approach inappropriate, it is common practice to assume negligible contribution from loss processes (provided the sample is essentially solid-like throughout) and apply the simple models shown above. For clarity, these are

Page 45: Instrumental

28

derived here using the two-layer physical models rather than the more simple method with mechanically descriptive viscoelastic elements.

For the isostress case, (Figure 13a), the extensional force F is applied perpendicular to the interface between the two materials X and Y over the common area A, their moduli being E x and Ey respectively. If the original thicknesses of the layers (L x and Ly) are extended by amounts AL x and ALy then the modulus of the whole sample is:

Eo= F(L• + Ly) (34) A(AL~ + ALy)

where _ FLy A L~ FLx and ALy - " (35)

AE~ AEy

hence Ec = E•215 + ty) (36) E~Ly + EyL•

By inverting both sides, we obtain

1 L X L , . - - = �9 + ( 3 7 ) E~ E~(L• + Ly) E:,(L~ + Ly)

Since the area A is common to both layers, this reduces to

1 _ r ~ , , , ( 3 8 ) Ec E x Ey

For the isostrain case, the force is applied parallel to the interface as in Figure 13b. Here, F is the sum of the forces F x and Fy acting on areas A x and Ay to produce a common strain 7c in the two components.

i.e. F = F x + Fy (39)

where F x = ExAx,/c (40)

and Fy = EyAxY c (41 )

so that F = (ExA x + EyAy)~ c (42)

Since modulus (E) = total force (F)/[(area (A) * strain (u

then E = (ExA• + Eymy)~/~ (43) 7c(A• + Ay)

Page 46: Instrumental

29

Figure 13. Schematic diagrams of the (a) isostress and (b) isostrain models.

Since the sample length is common, the area of each phase is proportional to its phase volume ~, i.e. ~x = Ax/A, ~)y = A / A

so that E c = ,xEx + ,yEy (44)

Although these upper and lower bound models represent a simplification of the true situation, their usefulness lies in defining an area of modulus versus composition in which experimental results should be confined if the rigidity of the material is determined by simple phase separation [46].

Water distribution within mixed biopolymer systems

In the case of binary aqueous gels an extra complication is introduced by the presence of solvent as a third component which can partition itself between the two polymer constituents. The resulting phase volumes (r and Cy) depend on the relative powers of the two polymers to attract solvent and must be found before equations (32) and (33) can be used. To help surmount this difficulty, Clark and his group introduced a new parameter, p, in a study of phase-separated agar and gelatin mixed gels [47]. This parameter is a measure of the solvent partition between the two phases and enables the effective local polymer concentration in each phase to be estimated as p is allocated different values. These adjusted concentrations are then used to calculate the gel modulus of each phase based on suitable fits for the relationship between gel modulus and concentration and hence an overall modulus, for comparison with the experimental data, can be calculated using the simple Takayanagi treatment.

Page 47: Instrumental

30

Considering an aqueous system of total mass W containing two polymers X and Y of respective masses x and y, then the mass of water available for distribution within the system is

w = W-x-y (45)

Assuming that a fraction a of the water becomes associated with polymer X then

mass of X phase = x + txw (46)

mass of Y phase = y + (1 - aw) (47)

The effective concentrations of the two phases are, therefore

X Cx(eff) = ~ (48)

(x +aw)

Cy(eff) = Y (49) ( y + ( 1 - a ) w )

ff the densities of the two phases are D x and Dy, respectively, then their volumes are given by:

Vx = (x + a w ) (50) Dx

and (y +(1- a)w) (51) Vy-- D

y

Thus, the phase volumes of the components are

W x D y ( X + a w )

v~+Vy [ D y ( x + a w ) -I- Dx(y + (1- a)w)] (52)

Vy D~(y + ( 1 - a)w) and Cy "-- ~ -" + Vy [Oy(X o (y

(53)

In many biopolymer gels, the polymer concentration is small so that D x ~ Dy ~ 1. Hence the p parameter is simply defined as

a / x ay p . . . . (54) ( 1 - a ) / y (1-a)x

Page 48: Instrumental

31

px so that a - (55) px+y

this can be substituted in equations for effective concentration and phase-volume to give, for instance

Cx(efD = (px + y) (56) Wp +(1-p)y

Recently, the distribution of solvent (water) between two biopolymer phases was explored rheologically by calculating the values of storage modulus for all possible distributions and finding which ones matched the experimental values [48].

The computerised output of this approach is shown in Figure 14 where the solvent position is defined by S x (aw), the fraction of water present in the polymer X phase.

Figure 14.

e , .

o u

. . . . . . . . .

I i

I I

/ I

UPPER BOUND (Gu) / t POLYMER X ~ / / (Solid line)

//

(Dashed line) / LONWER BOUND (GL) ( D a s h e ~ ) / LO"~WER BO~ID (GL)X~

0 Sx 1

Changes in calculated modulus as a function of S x, the solvent fraction in the X phase. The solid lines show the upper and lower bounds for polymer X whereas the broken lines show the corresponding bounds for polymer Y, from [48] with permission.

Page 49: Instrumental

32

At very low biopolymer concentration, Sx and (1-Sx) are virtually identical to the phase volumes 0x and r At higher concentrations the values diverge but Cx and or can be readily calculated Irom S x by taking account of the direct contribution ~ the polymers to phase volume. Knowing the starting concentrations of X and Y, Sx determines the final concentrations in the individual phases, which in turn gives the moduli Gx and G., of the two phases from experimental calibration curves (e.g. cascade fit [49,50]~. The overall moduli of the composite gels can then be calculated by the isostrain and isostress blending laws. As described above, the former applies when the continuous phase is stronger than the dispersed phase, and gives an upper bound modulus (Gu); the latter gives a lower bound value (GL) when the dispersed phase is stronger. At very low values of Sx, where most of the water is in the polymer Y phase, polymer X is extremely concentrated, and thus G x >> Gy. Conversely, at very high values of Sx, G x << Gy. At one critical value of S x, the moduli of the two phases cross over (with G x = G, = G U = GL). Up to this point, the 'upper bound' value (Gu) corresponds to a p o l y m J X continuous system, with the matrix harder than the filler, and the lower bound value (GL) to a polymer Y continuous, with the matrix weaker than the filler (Figure 14). At higher values of S x, G U relates to polymer Y continuous and G L to polymer X continuous.

Kinetic influences in the gelation-phase separation of mixed biopolymer systems

The theoretical modelling of the preceding section has been applied to composites of maltodextrin/gelatin, maltodextrin/sodium caseinate, maltodextrin/denatured milk protein and denatured milk/soya proteins, thus providing a general outline of phase separation in systems widely used in manufactured foodstuffs [51]. In the case of maltodextrin/milk protein, results are summarised in Figure 15 where the milk protein is regarded as polymer X throughout, so that the parameter S x refers to the fraction of solvent in the milk protein phase. Mixed gels were prepared using a fixed concentration of milk protein (16.5% w/w) with maltodextrin concentration from 2% to 18% w/w. Analysis of the phase separation between the two components (Figure 15a) indicates phase inversion from a weak, protein-continuous phase (lower bound) to a strong, maltodextrin matrix (upper bound) at about 13% maltodextrin. Solvent fractions derived from Figure 15a were used for analysis of water partition between the two phases (Figure 15b), yielding p = 1.7 (log p = 0.23) for the intercepts in the milk protein continuous systems, whereas the data beyond the phase inversion point (maltodextrin continuous systems) are better fitted with a value of p ~ 1.1 (log p

0.04).

A similar variation in the p values as a result of phase inversion was documented in the remaining biopolymer mixtures with either component holding disproportionate amounts of solvent in its phase when it formed the continuous matrix. Provided that phase inversion does not affect the mechanical analysis via interfacial effects, it follows that the difference in p values is the result of phase separated gels being trapped away from equilibrium conditions, since the equilibrium value of 'relative affinity' of the two polymers for water should not be affected by the geometrical rearrangemems of their phases in a binary mixture. Therefore, the p parameter, at least for the gels of this investigation [51 ], is not an equilibrium concept but a single point measurement in the experimentally accessible time-temperature continuum.

Page 50: Instrumental

5 . 5

4.5

2.5

1.5

0 0.2 0.4 0.6 0.8 1 -1 -0.5 0 0.5 1 s x log P

Figure 15. Calculated bounds for 16.5% milk protein with maltodextrin concentrations as shown (Yow/w), plotted (a) as a function of solvent fraction in the milk protein phase (SJ, and (b) solvent avidity parameter p. In the milk protein continuous systems (2-12 % maltodextrin), only the lower (isostress) bounds are drawn, whereas above the phase inversion point ( 13- 18% maltodextrin) the upper bound (isostrain) predictions are illustrated. Experimental values ( 0 ) are shown to intercept the bounds and the experimental modulus for 16.5% milk protein alone is noted by the

W W arrow on the right-hand axis, from [ 5 1 1 with permission.

Page 51: Instrumental

34

Independent evidence of the kinetic influences on the formation of composite gels was obtained when the gelatin-maltodextrin system was subjected to disparate cooling regimes [52]. Figure 16 reproduces changes in the storage modulus as a function of quench and controlled cooling regimes for gelatin-maltodextrin solutions prepared at 70~ In the case of quench cooling to 5~ there is a sharp increase in the values of storage modulus beyond 15% maltodextrin which is coincident with the phase inversion from gelatin to maltodextrin continuity in the co-gels. Below the phase inversion point, mixed solutions remain clear, and upon gelation show a steady reduction in experimental moduli with increasing maltodextrin concentration. This was rationalised on the basis of gradual deswelling of the gelatin network due to ordering of the polysaccharide component after gelatin gelation. For the maltodextrin continuous combinations, however, samples become cloudy upon mixing at 70~ and G' results are better described on the basis of immediate phase separation in solution and separate gelation of the two biopolymers.

In the event of controlled cooling at 1 ~ mixed preparations with a maltodextrin content up to 7.5% are clear during the cooling cycle (from 70 ~ to 5~ and show the familiar reduction in moduli of deswelled gelatin networks. At concentrations of maltodextrin between 10% and 15%, samples are still clear at 70~ but become turbid during controlled cooling and there is an immediate reinforcing effect on the composite strength as a result of the networks being formed at higher concentrations than the nominal, since the whole volume is no longer available to either component. Subsequent heating indicates gelatin continuous mixtures since a gelatin-related heating profile is recorded (melting at ~ 30~ At maltodextrin concentrations of 17.5% and 20% turbidity is observed upon mixing (70~ but there is no question that these gels (5~ have become maltodextrin continuous (like their quenched counterparts), since they also collapse at an early stage during heating, at about 30~ At higher concentrations (22.5% to 30%), mixtures phase invert to give a maltodextrin continuous situation with a prolonged melting behaviour (> 80~ In conclusion, it was surmised that reduction in cooling rates allows for more complete phase separation before gelation 'freezes' the system, and results in reinforcement of the continuous phase which now can support higher volume fractions of the dispersed phase (filler) before phase inversion finally occurs.

THE APPLICATION OF WILLIAMS, LANDEL AND FERRY KINETICS TO THE HIGH SOLIDS BIOPOLYMER SYSTEMS

High-solids systems- those with substantial concentrations of biopolymers and/or co- solutes - are of increasing academic and industrial interest. Typically, confectioneries have 10-20% moisture in the finished product and a high proportion of sugars. These products are almost exclusively manufactured by the process known as 'starch moulding' in which a hot (e.g. 80~ solution of all the ingredients at typically 20-30% moisture (liquor) is deposited into impressions made in the surface of 'dry' starch powder filling a shallow tray. The excess moisture is extracted by 'stoving' the sweets in the starch at a moderate temperature (about 50~ for an extended period of typically several days. Single and mixed biopolymer systems are used to formulate products with rubbery/glassy texture but the mechanistic understanding of viscoelastic

Page 52: Instrumental

I Gelatin continuous I Maltodextrin continuous 4 I

Turbid on Clear on

cooling I cooling (lO/min) I (10/min)

- 1 I I I I I I

I I

A I

I A

I A

0 0 0

Gelatin continuous 4Clear on quenching

A A

Turbid I I I at 70°C 1 - 1 6

I I a

A t I

' A I A I 0 I

0

I I

b I Maltodextrin continuous I Turbid at 7OoC

I

1 ' I I I I I I

0 5 10 15 20 25 30 35 Maltodextrin ( YO)

Figure 16. Development of modulus for gelatin-maltodextrin mixtures as maltodextrin content is varied, when quench-cooled (0), and when steadily cooled at l"C/min (A), from 70°C to 5°C.

w ul G values were recorded after 7h at 5°C following the cooling scan, from [52] with permission.

Page 53: Instrumental

36

and textural properties is lacking. However, the structural properties of non-crystalline synthetic polymers are well described by Williams, Landel and Ferry kinetics (WLF) based on free volume theory, which follows the transition from a rubbery state at high temperature to a glassy state on cooling.

The application of the WLF approach to aqueous preparations of biopolymer gels can fail due to development of crystallinity or intermolecular enthalpic interactions as a function of temperature, resulting in a change in the distribution of relaxation times not simply related to the temperature-dependence of the free volume [53]. The recent paper by Lopes da Silva et aL on pectin dispersions only highlights the problem with the authors stating 'but a smooth master curve could not be obtained for both moduli simultaneously or for each one individually .... satisfactory reduction of the data to a single curve was not obtained, irrespective of the frequency shift factor used, for each modulus individually or with vertical shift factors higher than those calculated by the experimental temperature-density factor' [54]. Work in this laboratory has now documented the transition from rubber-like to glass-like consistency for high solids gellan gum and high methoxy pectin samples. Such information might prove to be instrumental in the development of appealing novel confectioneries. Before that, however, we feel that a treatise on the free volume-WLF theory, tailored for the food scientist, is necessary.

The Free Volume-WLF Kinetics Theory

Free volume is a useful concept closely related to the hole theory of liquids, and the approach has been more successful than any other model in describing the glass transition in synthetic polymers. The total volume per mole u is pictured as the sum of the free volume uf and an occupied volume u o. Ferry takes u o as including not only the van der Waals radii but also the volume associated with local vibrational motion of atoms [55]. The free volume is therefore that extra volume required for larger scale vibrational motions than those found between consecutive atoms of the same chain. Flexing over several atoms, that is, transverse string-like vibrations of a chain rather than longitudinal or rotational vibrations will obviously require extra room. The glass transition temperature (Tz) is defined on the free volume concept as that temperature at which uf collapses sensibly to zero, or at any rate to a fixed, low value. Large scale mobility has therefore been totally restricted and the only movement below Tg is that allowed by the occupied volume u o.

To move from a qualitative description to quantitative treatment, experimental work on the viscosity of the alkanes over a wide range of temperature was carried out and Doolittle found that the simple relation [56]:

q = A exp (B/fu) (57)

fitted the results more precisely than the Arrhenius equation:

rl = A exp (B/T) (58)

where the values of A and B remain unchanged during a temperature ramp.

Page 54: Instrumental

37

Unlike equation (58), in equation (57) log viscosity is not a linear function of temperature with fu being the fractional free volume. Qualitatively, fu is:

fu = (UT- UTo)/UT o (59)

where u T is the specific volume at a reference temperature T o. A quantitative �9 o 0 ~ �9 definition of the fractional free volume is:

fu = fuo + cxf(T - To) (60)

In equation (60), fuo denotes the fractional free volume at an arbitrary chosen reference temperature and czf gives the coefficient of expansion of the free volume when the sample temperature changes from T o to T [57]. The above mathematical expression can be used to replace fu in the Doolittle equation (57) yielding the following for viscosity:

In {rl(T)/rl(To) } = {-CI(T - To)}/(C 2 + T - To) (61)

At any reference temperature To, therefore, C 1 and C 2 are functions of the fractional free volume and of the expansion coefficient of flee volume being respectively equal to B/fuo and f uo/etf. In synthetic polymers, the thermally-induced transition from rubber-like to glass-like consistency maintains a characteristic spectrum of relaxation times (absence of crystalline or enthalpic processes). In view of this, Williams, Landel and Ferry used the above empirical equation to combine viscoelastic data from a wide range of temperatures into a composite (or master) curve. Thus it was found that the viscosity of synthetic polymer melts measured at shear rate ~ and temperature T, is equivalem to viscosity measured at shear rate $ a T and the reference temperature T o. Therefore for viscosities aT, the horizontal shift factor, is the ratio rl(T)/rl(To). Of course, reduction of data to T o and the production of a single composite curve can be achieved for any modulus function-G"(c0), G'(t), E(t), etc (time-temperature superposition principle; TTS). For over forty polymers and diluted systems (polyisobutylene, polystyrene, polybutadiene, etc) Ferry and his colleagues demonstrated the utility of equation (61) and in conjunction with the concept of free volume argued for the universality of relaxation processes at the glass transition temperature regardless of chemical structure.

Although the combination of time-temperature superposition with the free volume approach created a comprehensive model of glassy phenomena, the method of thermorheological reducibility has been shown before to work empirically [58]. In Figure 17, a series of curves is obtained by plotting creep curves, taken at different temperatures, against In(time). Below 25~ the experimental frequency range appears to correspond to the glassy zone; the compliance is quite low and does not change much with frequency. Above 55~ the behaviour appears to correspond to the plateau zone; the compliance is characteristic of a very soft rubber-like solid, and again changes only slowly with frequency. At intermediate temperatures, the transition zone makes its appearance. As illustrated in Figure 18, horizontal shifting of the data along the In(time) axis results in a continuous master curve over a long time regime with each superposition step defining the shift factor between successive experimental temperatures.

Page 55: Instrumental

38

1000

Figure 17.

~, 100 "7 Z

t",,I

10

E 0

1

0.1

60 ~ ~ , , 55 ~ 39 ~ 50 ~

35 ~ 45 ~

30 ~

25 ~ ~ 23 ~

1 10 100 1000 10000

Time (s)

The compliance of a flexibilised epoxy resin as a function of time and temperature, from [58] with permission.

1000

Figure 18.

_--" 100

r

10

O 1

0.1

/

Reduced time

Master curve for Figure 17, produced by horizontal time-temperature shifting, from [58] with permission.

Page 56: Instrumental

39

Figure 19 shows the temperature dependence of lnot T for the data of Figures 17 and 18. If the dependence of the relaxation time on temperature had followed the Arrhenius relation (equation (58)) the following expression would have emerged:

lntx T = (AH/R) {(l/T) - (1/To) } (62)

Equation (62) relates to a constant activation energy for the experimental temperature range and is obtained from the gradiem of a linear relationship between lno~ T and 1/T. This type of relationship, of course, occurs for polymers at regimes below and above the glass transition area. In Figure 19, however, a curve is obtained which in accordance with the analysis of the preceding paragraph argues strongly for a non-An'henius process.

in 13[~T

2.8 2.9 3.0 3.1 3.2 3.3 3.4

1000 K/T

Figure 19. Plot of the shift factor w r against inverse absolute temperature for the master curve of Figure 18, from [58] with permission.

Page 57: Instrumental

40

The Application of the WLF Approach to High-Solids Food Biopolymer Systems

The high solids work in this laboratory originates from a programme of background research to address the problem of gelatin-based sweets sticking together when stored at high temperature. The immediate aim was to explore the possibility of using the new food polysaccharide, gellan gum, to create a continuous heat-stable matrix, with gelatin dispersed through it as a discontinuous phase. The first step was to characterise the effect of high concentrations of dissolved solids (sucrose and corn syrup) on the gel properties of gellan alone. In the absence of co-solutes, gellan displays a sharp sol-gel transition on cooling, due to the formation and cation-mediated aggregation of intermolecular double helices. Addition of co-solutes up to a concentration of about 50% w/w had the anticipated effect of raising the gelation temperature.

At higher concentrations, however, an entirely different pattern of response was observed. Mechanical spectra recorded at high temperature were qualitatively similar to those of gels ( G ' > G", with little frequency-dependence of either modulus). On cooling, the spectra become more like those of biopolymer solutions (G" > G', with both values increasing steeply with increasing frequency of oscillation) [59]. For example a mixture of 0.5% gellan, 50% sucrose and 35% corn syrup produces the mechanical spectrum of a rubbery material at the highest experimentally accessible temperature of 90~ (Figure 20). This contrasts strongly with the Newtonian behaviour of single solute and gellan solutions at 90~ Subsequent cooling produces a four decade change in the values of in-phase and out-of-phase components with the viscous component dominating throughout the experimental frequency range (mechanical spectrum at 5~ in Figure 20).

Although not previously seen for a biopolymer in a high-water system, such behaviour is well known for synthetic polymer melts, as described above, and corresponds to a transition from a 'rubbery' state at high temperature to a 'glassy' state on cooling. Using the WLF example, therefore, frequency sweeps of the elastic and viscous components at 90 ~ 70 ~ 50 ~ 30 ~ and 5~ were successfully superimposed according to the TTS principle at 90~ (reference temperature), showing that the vitrification of the above gellan-solute system commences at about 700 Hz. This is shown in Figure 21a where it is laid alongside the classic logarithmic plots of G' and G" against frequency near the onset of the transition zone, for poly(n-octyl methacrylate) at 100~ (Figure 21b), as shown by Ferry and co-workers [55].

Heating of the samples from 5 ~ to 90~ produces what would be an extremely unusual 'melting' profile for polysaccharide gels [60]. Figure 22 emphasises the difference in the characteristic temperature dependence of shear modulus in gellan networks with and without sucrose. Similarly to every single hydrophilically gelling polysaccharide, reduction in network strength with increasing temperature produces a negative gradient of modulus change as a function of absolute temperature (T) for aqueous gellan gels. By contrast the positive relationship between elastic modulus and temperature in the high solids gellan structures yields a family of constant gradients in the G'/T v s . T graph, typical of the temperature dependence of a rubber.

Page 58: Instrumental

41

4.3

I

3.3

;::s m

= 2.3 O

4.7

Q

3.7 -

2.7 ' 0.001

m m mm mmm m mm o

n [ ]

o o [ ]

o [ ] [ ] [ ] a 9 0 ~

. . . . . I I I

4.3

3.3

2.3

m m m m m m

0 [ ]

[ ] [ ]

(3 0

I I I

7 0 ~

5.3

m m m m

13 cl

n 13

o o

mmlml �9 o [ ]

50 ~

4.3

3.3 []

m m I mmmmml

[]

r, �9

�9 n

�9 a 3 0 ~ [] []

0.01 0.1 1 10 0.001 0.01 0.1 1 10 Frequency (Hz) Frequency (Hz)

7.0

c~ 6.0

Q

E 5.0 O

4.0 0.001

0

0 [] mm 5 ~

[]

0 �9

| i a i 11111 I i i a I l i a | A | i | i i 1 , ! i | i i lmJJ

0.01 0.1 1 10 Frequency (Hz)

Figure 20. Storage (m), and loss (D) moduli vs. frequency, recorded at intervals during stepwise cooling of 0.5% gellan with 50% sucrose and 35% corn syrup, at 0.5% strata. Scan rate between steps 1 o/ram., from [59] with permission.

Page 59: Instrumental

a

3 ' -4 -2 0 2 4 6

log w at 90°C (Hz)

' 6 M 0 I

b

-2 0 2 4 6 8

log w at 100°C (Hz)

Figure 2 1. The results of time-temperature superposition of mechanical spectra for (a) gelldcosolute mixtures at 9OoC, and (b) poly(n -0cty1 methacrylate) at 100°C, in both cases covering most of the plateau zone and part of the glass-transition region, from [59] and [ 5 5 ] with permission.

P h)

Page 60: Instrumental

43

100

--....

10

0.1

1.5% gs

0.5% gns 0.75% gs

0.3% g ~ . . . . . , , . . , , . . , . ~ ~ - -

i l i I i I i I

280 300 320 340 360

Absolute temperature (T/K)

Figure 22. The dependence of G'/T on absolute temperature (T) for gellan networks with and without cosolute (50% sucrose + 20% corn syrup), denoted as gs and gns respectively alongside the individual traces, from [60] with permission.

Application of the WLF analysis to the high-methoxy pectin samples in the presence of high levels of sugars (from 70% to 86%) successfully combined mechanical spectra over 110 degrees centigrade (from 90~ to -20~ thus producing the master curve of Figure 23a [61]. Clearly the plateau zone at lower frequencies gives way to a sharp modulus development which covers most of the glass transition region. The transformation is also evident in the tan 8 (G"/G') values which rise continuously up to a log frequency of = 3 thus underlining the dominance of the viscous component (Figure 23b). The decline in tan 8 values at higher frequencies is indicative of the eventual advent of the glassy state where the solid-like response is again dominant, with G' and G" traces crossing over and tan 5 passing through the value of 1 for the second time at frequencies > 10 6 Hz. Straightforward calculations produced glass transition temperatures for the high-solids gellan and pectin systems of-26~ and -53~ respectively. Gratifyingly, estimation of the fractional free volume fig) at Tg gave values (0.029 + 0.0003) almost identical to those observed for the great majonty of diluted/undiluted synthetic polymers [55], organic liquids of low molecular weight [57], and inorganic glasses [62] (fg = 0.026 + 0.005), thus demonstrating for the first time the generality of the free volume approach for biological glasses.

Page 61: Instrumental

8.5

0

O J

8.0

7.5

7.0

6.5

6.0

5.5

5.0

4.5

4.0

3.5

- a []

0 O m

13 m O I

cV G" O I Bill

j G'

44

b

/

G'

1 i i I I I I

-3 -2 -1 0 1 2 3 4 5 6 -3 -2 -1 0

1.08

Log (Frequency/Hz)

1.06

1.04

1.02

1.00

0.98

0.96

0.94 1 2 3 4 5 6

Log (Frequency/Hz)

Figure 23. Graphs illustrating the application of the method of reduced variables to storage modulus (G'), loss modulus (G"), and tan ~ for the 1% pectin + 86% cosolute preparation, at the reference temperature of 90~ from [61 ] with permission.

Having made a start in understanding the behaviour of high sugars biopolymer preparations, from a commercial point of view the intention should be to generate fundamental understanding for a wide range of food biopolymers in order to provide substitutes for conventional ingredients in established technology, and to design novel, appealing low-moisture products on a more rational basis. Fundamental research in high-viscous, low-water content materials has long been neglected by food scientists though the area has recently seen rapid growth mainly due to work on starch and globular proteins [63]. Such work on biogums provides an opportunity to glean and apply information from the realm of synthetic polymer science to the specialised problems of food biopolymers. Today, the confectionery industry is still rather conservative and somewhat resistant to new ideas, but there is a great deal of untapped potential for research and hopefully, as a result, commercial applications. For example, if research can scientifically demonstrate that technologically appealing rubbery or glassy materials can be made using otherwise brittle aqueous gels of polysaccharides like gellan, carrageenan or agarose, it will open up the possibility of development of suitable substitutes for traditional ingredients (gelatin and pectin) in the jam and confectionery industries.

Page 62: Instrumental

45

LOW FAT SPREADABLE PRODUCTS

Besides the high solids systems of the preceding paragraph, biopolymers are used increasingly in the manufacture of low fat spreads and soft cheeses. Creation of textures similar to those of fat-based food products such as butter and margarine requires processing of polysaccharides and proteins to generate particles of comparable size to fat crystals. Starch and gelling maltodextrins in mixtures with proteins (gelatin, milk and soya proteins) have been used to generate fat-like rheology by cooling a fluid mixture of two components, with development of discrete, micro- sized particles in a continuous matrix then occurring due to spontaneous phase separation between the two biopolymers [64]. Prediction and control of the final properties of such products, however, is in general largely empirical. In this context, the traditional technique of compression testing has been used with some success in identifying satisfactory substitutes of fat in spreadable samples.

Compression testing is able to differentiate between the long range properties of a hydrocolloid gel, a spreadable dispersion and a viscous solution (Figure 24; [65,66]).

100

15

HYDROCOLLOID GEL

10 ra~

m O'm ~p

Figure 24.

I I

I - - - . J - ~ ~ I - - - I i .... t i t ~ I PLASTIC DISPERSION

I I

I t I VISCOUS SOLUTION ~ ~ - - - l ,.. I . . . . . . .

I I I , I

~m ~m Ep

strain

0.5 2

Idealised force-deformation profiles from compression testing of a hydrocolloid gel, a plastic dispersion, and a viscous solution, from [65] with permission.

Page 63: Instrumental

46

In the case of gels, the yield stress (Crm) is the point where the force goes through a maximum value before its rapid decline at higher levels of compression. A minimum point is also observed after failure (cri), since the stress will eventually rise due to the dosing down of the stationary and moving plates. The deformation at maximum stress is known as yield strain (em) and is related to the elastic properties of the network. Overall, a sharp and early profile of breakdown is characteristic of a gel as opposed to the smooth stress-strain trace of a viscous liquid (e.g. a thick yoghurt) that does not show apparent signs of a yield point on the curve. Between the two extremes of gels and viscous liquids, butter and margarine show ideal spreading properties (plastic rheology) generating a shallow shoulder followed by a plateau (crJcr m = 0.96 to 1.0), rather than a pointed peak under a constant compression rate (typically 2"/min). In the case of low fat products, the lack of in-depth understanding of binary biopolymer systems has resulted in the past in commercial products with an excessive gel-like character [65]. Intelligent manipulation of biopolymer mixtures in terms of phase continuity, kinetics of gelation/phase separation and solvent distribution between the two networks, as outlined in the section of phase separated networks, allowed recently the development of spreadable very low fat products. Thus a formulation of 2.3% milk protein, 9.5% maltodextrin, 5% fibre (inulin) yields a O'p/O" m ratio of 0.96 and a stress-strain profile upon compression identical to that of margarine at a fat content of only 5.2% in the formulation [67].

ACKNOWLEDGEMENTS

The authors are grateful to their colleagues, Dr M.W.N. Hember and Professor E.R. Morris for stimulating discussions and technical assistance in the preparation of this manuscript.

REFERENCES

.

3.

.

Cheftal JC, Cuq JL, Loivent D. In: Fenemman OR, ed. Food Chemistry. New York: Marcel Dekker Inc., 1985; 245-371. Rees DA. Biochem J. 1972; 126: 257-273. Holmes KC, Blow DM. In: Glick D, ed. Methods of Biochemical Analysis. New York: John Wiley & Sons, 1966; 113-239. Amott S, Mitra AK. In: Amott S, Rees DA, Morris ER, eds. Molecular Biophysics of the Extracellular Matrix. Clifton NJ: The Humana Press Inc., 1984; 41-67. Ross-Murphy SB. In: Chan HW-S, ed. Biophysical Methods in Food Research. Oxford: Blackwell Scientific Publications, 1984; 138-198. Arridge RGC. In: Mechanics of Polymers. Oxford: Clarendon Press, 1975; 51-57. Ferry JD. In: Viscoelastic Properties of Polymers. New York: John Wiley & Sons, 1980; 177-223. Rouse PE Jr. The Journal of Chemical Physics 1953; 21: 1272-1280. Zimm BH. The Journal of Chemical Physics 1956; 24: 269-278.

Page 64: Instrumental

47

10. 11. 12. 13. 14. 15. 16.

17.

18. 19. 20. 21.

22. 23.

24.

25. 26. 27.

28.

29.

30.

31.

32. 33. 34. 35.

36.

37.

38.

39.

40.

Cox WP, Merz EH. J Polym Sci 1958; 28:619. Cross MM. J Colloid Sci. 1965; 20: 417-437. Morris ER. Carbohydrate Polymers 1990; 13: 85-96. Graessley WW. J Chem Phys 1967; 47: 1942-1953. De Gennes PG. The Journal of Chemical Physics 1971; 55:572-579. Doi M, Edwards SF. J Chem Soc Faraday Trans. II 1978; 74: 1789, 1802. Robinson G, Ross-Murphy SB, Morris ER. Carbohydrate Research 1982; 107: 17-32. Goycoolea FM, Morris ER, Gidley MJ. Carbohydrated Polymers 1995; 27: 69-71. Clark AH, Ross-Murphy SB. Adv. Polym. Sci. 1987; 83: 57-192. Richardson RK, Ross-Murphy SB. Int. J. Biol. Macromol. 1987; 9: 257-264. Barnes HA, Walters K. Rheological Acta 1985; 24: 323-326. Moldenaers P, Mewis J, Berghmans H. In: Giesekus H, Hibberd FF, eds. Progress and Trends in Rheology II. Darmstadt, Germany: Seinkopff Verlag, 1988; 420-421. Richardson RK, Goycoolea FM. Carbohydrate Polymers 1994; 24: 223-225. Yalpani M. In: Polysaccharides Syntheses, Modifications and Structure/Property Relations. Amsterdam: Elsevier, 1988; 410-413. Barnes HA, Hutton JF, Walters K. In: An Introduction to Rheology. Amsterdam: Elsevier, 1989; 119-131. Huggins ML. J. Amer. Chem. Soc.a 1942; 64: 2716-2718. Kraemer EO. Ind. Eng. Chem. 1938; 30: 1200-1203. Solomon OF, Gut~ IZ. Journal of Applied Polymer Science 1962; 24: 683-686. Morris ER, Cutler AN, Ross-Murphy SB, Rees DA, Price J. Carbohydrate Polymers 1981; 1: 5-21. Kasapis S, Morris ER. In: Nishinari K, ed. Food Hydrocolloids: Structures, Properties, and Functions. New York: Plenum Press, 1994; 97-103. Morris VJ. In: Phillips C~, Wedlock DJ, Williams PA, eds. Gums and Stabilisers for the Food Industry 3. London: Elsevier, 1986; 87-99. Nielsen LE. In: Mechanical Properties of Polymers and Composites. New York: Marcel Dekker Inc., 1974; 496-501. Mitchell JR, Blanshard JM . Journal of Texture Studies 1976; 7:219-234. Mitchell JR, Blanshard JMV. Journal of Texture Studies 1976; 7:341-351. Stainsby G. Fd. Chem. 1980; 6: 3-14. McKay JE, Stainsby G, Wilson EL. Carbohydrate Polymers 1985; 5: 223-236. Whistler RL. In: Whistler RL, BeMiller JN, eds. Industrial Gums- Polysaccharides and their Derivatives. San Diego: Academic Press, 1993; 309-339. Imeson AP. In: Phillips GO, Wedlock DJ, Williams PA. eds. Gums and Stabilisers for the Food Industry 2. Oxford: Pergamon Press, 1984; 189-199. Lin CF. In: Graham HD, ed. Food Colloids. Westport Conn.: AVI Publishing Co, 1977; 320-346. Toft K. In: Phillips GO, Wedlock D J, Williams PA, eds. Prog. Fd. Nutr. Sci. Oxford: Pergamon Press, 1982; 89-96. Thom D, Dea ICM, Morns ER, Powell DA. In: Phillips GO, Wedlock DJ, Williams PA, eds. Prog. Fd. Nutr. Sci. Oxford: Pergamon Press, 1982; 97-108.

Page 65: Instrumental

48

41.

42.

43.

44.

45.

46.

47.

48. 49. 50.

51.

52.

53.

54.

55.

56. 57.

58.

59.

60. 61 62.

63. 64. 65. 66. 67.

Dea ICM, Clark AH, McCleary BV. Carbohydrate Research 1986; 147: 275-294. Kasapis S, Morris ER, Norton IT, Brown CRT. Carbohydrate Polymers 1993; 21:261-268. Tolstoguzov VB. In: Mitchell JR, Ledward DA, eds. Functional Properties of Food Macromolecules. London: Elsevier, 1986; 385-415. Suchkov VV, Grinberg VY, Tolstoguzov VB. Carbohydrate Polymers 1981; 1: 39-53. Takayanagi M, Harima H, Iwata Y. Mem. Fac. Eng. Kyusha Univ. 1963; 23: 1-13. Arridge RC~. In: Mechanics of Polymers. Oxford: Clarendon Press, 1975; 97-103. Clark AH, Richardson RK, Ross-Murphy SB, Stubbs JM. Macromolecules 1983; 16: 1367-1374. Morris ER. Carbohydrate Polymers 1992; 17: 65-70. Gordon M, Ross-Murphy SB. Pure Applied Chemistry 1975; 43: 1-26. Clark, AH. In: Blanshard JM , Lillford P, eds. Food Structure and Behaviour. London: Academic Press, 1987; 13-34. Kasapis S. In: Harding SE, Hill SE, Mitchell JR, eds. Biopolymer Mixtures. Nottingham: Nottingham University Press, 1995; 193-224. Kasapis S, Alevisopoulos S, Abeysekera R, Manoj P, Chronakis IS, Papageorgiou M. In: Phillips GO, Williams PA, Wedlock DJ, eds. Gums and Stabilisers for the Food Industry 8. Oxford: IRL Press, 1996; in press. Kalichevsky MT, Blanshard JMV, Marsh RDL. In: Blanshard, JMV, Lillford PJ, eds. The Glassy State in Foods. Nottingham: Nottingham University Press, 1993; 133-156. Lopes da Silva JA, Gonqalves MP, Rao MA. Carbohydrate Polymers 1994; 23: 77-87. Ferry JD. In: Viscoelastic Properties of Polymers. New York: John Wiley & Sons, 1980; 264-320. Doolittle AK. Journal of Applied Physics 1951; 22: 1031-1035. Williams ML, Landel RF, Ferry JD. Journal of the American Chemical Society 1955; 77: 3701-3706. Arridge RGC. In: Mechanics of Polymers. Oxford: Clarendon Press, 1975; 24-50. Papageorgiou M, Kasapis S, Richardson RK. Carbohydrate Polymers 1994; 25: 101-109. Papageorgiou M, Kasapis S. Food Hydrocolloids 1995; 9:211-220. A1-Ruqaie IM, Kasapis S, Richardson RK, Mitchell G. Polymer, submitted. Shen MC, Eisenberg A. In: Reiss H, ed. Prog. Solid State Chem. Oxford: Pergamon Press, 1966; 3:407-481. Kalichevsky MT, Blanshard JMV. Carbohydrate Polymers 1992; 19: 271-278. Goutefongea R, Semur J-P. French Patent 1986; FR 2 580 471 A1. Chronakis IS, Kasapis S. Carbohydrate Polymers 1995; 24: 000. Chronakis IS, Kasapis S. Lebensm.-Wiss. u. Technol. 1995; 28: 488-494. Gupta BB, Kasapis S. European Patent 1995; 0 672 350 A2.

Page 66: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 49

Destructive and Non-Destructive in Starch Analysis

Analytical Methods

Y.G. Moharram, O.R. Abou-Samaha and M.H. Bekheet

Food Science and Technology Department, Faculty Agriculture, Alexandria University, Alexandria, Egypt.

of

I -- INTRODUCTION

Starch is one of many hydrocolloids or water soluble resins. It is available from a variety of field crops such as corn, wheat, rice, potato and cassava or tapioca. It represents the storage carbohydrate in these plants. [i].

Starch present in a granular form. It is embedded in protein matrix. It has various shapes and sizes according to the source of starch. [2].

Starch granules have a heterogenous structure. It constructs from an amorphous and crystalline zones. Basically, it contains two main components, amylose and amylopectin and other minor constituents, particularly lipids and minerals. [3].

Amylose is a linear chain molecule with a limited branching. It forms from~anhdroglucose units connected by

-1,4 linkages. It is the component of starch which responsible about the characteristics of gelling, the precipitation or crystallization and a set-back or retrog radation. [4].

Amylopectin is a non linear or branched molecule. It consists of repeating anhydroglucose units connected by

-1,4 bonds but having ~-1,6 linkages at selected sites generating a branch point. It is a non gelling portion of the starch and generally contributes a pituitous or stringy consistency to food products because of its solubility. [1,4].

The method of starch isolation and the levels of non- starch components can affect the physicochemical properties of the starch. Phosphate is believed to be an important factor in determing the ganular strength, by forming cross- linkages, in isolated starches. [5].

Generally native starches lack the extended stability required by processed food. Therefore, it uses as dusting and flow agents for preparing fruit fillings, gravies, sauces, and confectionary. Processed food need pH, viscosity stability processing tolerance,textural properties shelf stability and good surface appearance. These characteristics can be obtained by modification the native starch with the proper method, acid hydrolysis or thinning, oxidation process, cross-linking, substitution, pregela- tinization and cold water (CWS). hydration in cold water, instant starch. [6.9].

The complexity of starch structure requires some

Page 67: Instrumental

50

methods to ensure its quality. Three met used viscosity profile chemical anal~sis of ~unctional ~ropert~es. [i0] ~ce destructive tec.niques are developed and the quality of starch such as controlled rheometers. Such procedures need a smal

hods are generally and determination

ntly. a new non usea to estimate stress or shear

1 quantity of raw materials and give more accurate and rapid results when compared with the destructive methods. The objective of this paper is to give knowledge on the utilization of such techniques, destructive and non destructive, in estimating the quality of starch after subjecting for food processing and/or modification.

2- Starch Isolation :

In particular, there are r.) strict rules for starch production. Also there are no two starch plants exactly a like. Local conditions, raw materials, available capital and preference influence the design and operation of the plant more than theoretical data. [ii].

Generally, the method of starch isolation can affect both the physicochemical properties of the starch and the levels of non starch components. In turn, the latter components may also influence the starch characteristics indirectly. [12, 13].

Fig. (i) summarizes the process of manufacturing starch from both cereals, and tuDers or roots.

Cereals

Cleanning

Steeping

Coarse milling

Degermination

Oil Extraction

Separating fibre from gluten and starch

Separating the gluten and starch

Drying the starch

Storage, Packaging and Transporting

Tuber or Roots

Washing and peeling

Milling

Coarse screening

Settling

Fine screening

Settling

Centrifuge or vacuum filtering

Drying the starch

Storage, Packaging and Transporting

Fig. (i) The process of manufacturing starch from cereals and tubers or roots.

Page 68: Instrumental

51

3- Starch Composition: Most of the common starches are composed of two major

polymeric components, amylose and amylopectin. The amount of amylose varies with the botanical source of starch. [14]. In 1984, Colonna and Mercier [15] added a third component known as intermediate fraction. It did not fit the dscription of either amylose or amylopectin and ranged from 5 to 10% in most cereal starches.

3.1- Amylose : It can be determined by potentiontiometric titration [16], amperometric titration [17], spectrophotometric determination of blue colour intensity of iodine complexes. [18] and the sorption of Congo Red. [19].

Takeda et al. [13] reported that amylose is generally assumed to be a linear polymer at ~-1,4 anhydroglucose link and limited amount of the branching long-chains. The molecular weight of amylose is about 250,000. It is varied not only between species but also within the same species according to the maturity stage. It has an unique properties such as the ability to form complex with iodine, organic alcohols and/or acids to form clathrate or helical inclusion components. [20]. The results of different researchers indicated that the amylose content of maize and rice starches was ranged from 22 to 32% with an average of 27% and from 15 to 23% with an average of 18.5% respectively according to the variety and the environmental conditions. [14, 21-24]. Schoch [25] classified the non-waxy rice varieties into two groups according to their amylose content, I~dica with 21-23% and Japonica with a relatively lower amylose content.

Sweet potato starch amylose content is slightly higher than that of cassava but less th~n of wheat, maize or potato [26].

3.2- Amylopectin: It is composed of ~-D glucose linked primarily by ~-,i-4 and branched by ~-i-6 bonds. [27]. It is considered one of the largest molecules found in nature with a molecular weight of about l0 s . [28]. Robin et al. [29] assumed that the amylopectin forms from three chains; A, composes of glucose linked by~-l,4, B, consists of glucose linked by ~-1,4 and ~-1,6; and C, forms from glucose with ~-1,4 and K-I,6 linkages plus a reducing group. The portion of the ~-1,6 linkage in a mylopectin is 4-5% [30].

3.3- Minor components:

3.3.1- Fat content: The old results of Taylor and Nelson [31] reported that there was a relatively low amount of fatty substances in commercial starches. They found that maize, rice, sago, cassava and potato starches contained 0.61, 0.83, 0.ii, 0.12 and 0.04% of lipids respectively. According to Gracza [32], the lipids content of rice starch

Page 69: Instrumental

52

obtained from Japonica varieties was higher (0.4-0.8%) than that produced from Indica ty~es (0 i-0 3%). In Ir:~, AI- Bayatl and Lorenz [33] found hat the lipids content rice starch ranged from 0.II to 0.14%.

In maize starch, the range of the lipids content was 0.2 to 0.92% according to the 9enotype and the method of determination. [34-38]. It was varied from 0.05 to 0.6% in sweet potato starch. [39].

3.3.2- Protein: The protein content of non-waxy rice and maize starches was varied from 0.24 to 1.93% and from 0.35 to 1.25% respectively. [34, 36-38, 40, 41]. The data of Ai-Bayati and Lorenz [33] showed that the protein was present in trace amounts in Iraqi rice starches. On the other hand, Wankhede and Umadevi [35] found that rice starch contained 2% protein. In case of sweet potato starch, the level of crude protein was ranged from 0.02-0.54% [39].

3.3.3- Ash: The ash content of rice starch was varied between 0.38 and 0.78% [42]. The results of Wankhede and Umadevi [35] indicated that the ash content of rice starch did not increase than 0.32%. It ranged from 0.09 to 0.54% according to the method used for its production as well as variety of rice [36-38]. Sweet potato starch had 0.008 to 1.3% ash. [39].

Generally, total carbohydrates are the main components of both native and modified sta:ches. It represents more than 98.5% in both maize and rice starches. The other components, protein, fat, and ash are minor and usually present in bound form with starch molecules. Their levels depend upon the source of starch and the degree of refinement. [38, 43]. Sweet potato starches contain amount of phosphorus (8-28 mg/100 g) similar to those in cassava and less than that in Irish potato. Amylose contains less phosphate than the amylopectin [44]. It is believed that phosphate plays an important factor in determining the granular strength, by forming cross-linkages,in starches. [5].

4- Starch Analysis :

4.1- Physical Methods:

4.1.1- Size and shape: The size of the starch granules may be estimated by the rate of sedimentation by the use an instrument such as Coulter counter or by microscopic analysis. Particle size is one of the characteristics that most markedly affects the functional properties of starch granules. Smaller granules are reported to have both high solubility and water absorption capacity [45, 46]. Small granules of wheat starch (1-8 Um) are more digestible, have a lower amylose content, iodine affinity, and molecular weight, higher gelatinization

Page 70: Instrumental

53

temperature range; water binding capacity , viscosity and more hygroscopic than large (25-35 Um) ones. [47-49].

Starch granules from different plant sources showed a wide variety in shape and size. The size of starch granule is usually expressed as a range or as an average of the length of the longest axis in microns [14, 50]. The shape of starch granules of the plants differ according to their growing climatic conditions. The damp conditions give starch granules large in size, regular in shape, and consisting of concentric layers around a dark spot known as the hilum. This hilum does l,ot always distinguishable, especially in very small granules. [14, 51-53].

The results of Waldt and Kehoe [54] showed that rice starch granules are polygonal in shape, small in size(3-8 u) and sometimes adhered together to form the clusters shape [48]. While the maize starch granules appear in two shapes, round in floury portion, and polygonal in the horny part of the endosperm [55], with a size range of 5-25 u [20].

The size of starch granules of sweet potato starch (10.2-21.5 Um) was found to be similar to those of cassava and corn but are smaller than those of potato which also have a larger range of granular size [56]. A negative correlation was observed between particle size and susceptibility to ~(.-amylase and acid degradation. J57]. Abou-Samaha [43] using Scanning Electron Microscopy (SEM) to get information about the~structural detail, especially the surface topography, of both maize and rice starches. Figs. (2-8) illustrate the influence of thin acid and moist heat modification on the structure of these starches. The granule of maize starch (Fig. 2) exhibits the polygonal shape. The flinty part of this granule is an angular in outline. The granules are nearly uniform in size 6.7-16.8 um, and no concentric rings found in it under light microscope. It has a fairly regular polyhedral shape and with well marked central hilum. However, the surface of the granules is appeared basically smooth. Some of the granules have an identations on their surface due to the method used for isolating of starch. Fuwa et al. [58] reported that, the small pin-holes which noticed on the surface of maize starch are irregular and resemble the surface of a golf-ball. This might be due to enzyme attack during long steeping used in isolation of the starch. In case of rice, the starch granules (Fig. 2) are smaller in size comparing with that of maize. It is mostly ranged from 3.3 to 8.3 um in their size. The granules are more or less polygonal in shape with an angular outline. It is difficult to identify the central hilum or stria of the granule under light microscope. Some of the granules are adhered together to form a compound or clusters shape. These results are in agreement with that reported by Waldt and kenoe [54]. As in case of maize starch, the rice starch granules were found to have smooth surface with small indentations. Nearly slight changes in the size and shape of the granules of maize and rice starches were noticed after treating, with either 1 or 2%

Page 71: Instrumental

54

Fig. (3) Scanning elecT.ron micrograpt~s of acid modified maize starch

(Acid concentrat;on 1%, 2-5x2000x) a=0.75 hr, b=1.5 hrs, c=6 hrs, d= 24 hrs.

Page 72: Instrumental

55

HCl for 0.75 to 24 hrs. (Figs. 3, 4, 6 and 7). The acid modification caused a slight hydrolysis of small parts of each of superposed concentric layers of the granules of both maize and rice starches. This may be removed por~lons os the less crystalline or less dense starch molecules outside the granules. Therefore, the surface of the granules became slightly rough. These changes were more pronounced with increasing the acid concentration and extending the time of modification especially in rice starch. On other hand, the moist heat treatment did not affect the shape and the surface characteristics of the granules of both maize and rice starches (Figs. 5 and 6). Only slight increase in the size os the granules of both maize and rice starches, by 2.0 and 3.1% respectively, was observed, such increase may be due to the swelling of the starch granules. Because this swelling did not destruct the outer layers, the granules are kept its smooth surface. Exten0ing the moist heating time from 5 to 21 hrs did not affect ~he ultra structure of maize and rice starches.

Bekheet [59] studied the effect of food processing in the ultra-structure of wheat starch. The SEM micrographs of native, steeped and boiled steeped wheat starch (Fig. 9) indicate that the granules are biconvex discs with fairly regular circular outlines, and free from polarization crosses. The size of native starches are ranged from 2 to 8 um for small granules and, from 25 to 55 mu. for large ones. When the starch granules soaked in water and diluted alkali at room temp., they absorbed solution, swelled, and increased 22 and 55 times in size respectively without any changes in their crystalline nature. The boiling of the granules for 5 min. before soaking increased from the solvent absorbing, swelling and size enlargement. These changes are more noticeable in dilute alkali than in water. Also, the lye treated starch granules had a rough surfaces and more flattened than those treated with water. This is may be due to the influence of diluted lye solution on solubilization some of the protein matrix surrounding the starch granules. As shown from Fig. (i0) the starch granules lost their birefringence, crystallinity and became nearly formless sacs having complex puckered structure after cooking. This can be contributed to the influence of heat on gelatinization of starch which causes distorting the crystalline structure and contraction of the dissociated molecules to a random coil conformation. Further heating and hydration, as show in Fig. (ii), caused weakness for this structure and produced a sol.

4.1.2- Density: The range of the density (g/cc) of some common starches was 1.49-1.517, 1.504-1.521, 1.479-18 and 1.5-1.528 for maize, tapioca, waxy maize and wheat respectively. [60]. Generally, the utilization of an air compression pycnometer for estimating the starch density gave lower value than xylene displacement method. Hussein et al. [61] found that the density of rice starch was 1.472

Page 73: Instrumental

55

Fig . (5) Scanning electron micrographs of moist heated modified maize starch (2-5x2000x). a=5 hrs, b=10 hrs, c=15 hrs, d=21 hrs.

Page 74: Instrumental

57

Fig. (6) Scanning electron micrographs of acid modified rice starch (Acid concentration 1%,2-5X2000x). a=0.75 hr, b=1.5 hrs, c=6 hrs, d=24 hrs.

Fig. (7) Scanning electron micrographs of acid modified rice starch (Acid concentration 2%, 2-5x2000x). a= 0.75 hr, b=1.5 hrs, c-~6|lrs, d=.24 hrs.

Page 75: Instrumental

58

"O

.~.

O

E II

L_

*.-. U")

~ O

II E O

.~

O

O

II E c=

~. O

~" O

O

O

x o')

,

o O

CO

~

Page 76: Instrumental

59

b Water steeped

d Boiled and water steeped

e

Boiled and alkali steeped

a

native

c Alkali steeped

,

Fig (9)" Scanning electron micrographs of native steeped and boiled steeped wheat starch

Page 77: Instrumental

60

Fig. (i0) ." Scanning electron micrographs of cooked wheat starch

Page 78: Instrumental

6!

Fig. (ii) " Scanning electron micrographs of sun and

mechanically dried wheat starch

Page 79: Instrumental

62

and 1.439 g/cc when measured by burette and by the volumetric flask methods respectively. EI-Refai [62] showed that the density of the Egyptian rice starch was 1.428-1.492 g/cc. Munk et al. [24]stated that rice starch had relatively higher density (1.518 g/cc) than maize one (1.514 g/cc).

According to Abou-Samaha [43] modification process either with acid at 1 and 2% and/or by moist heat treatment caused a slight increase in the density of both rice and maize starches. Generally, the density of maize starch (1.635-1.656 g/c.c) was relatively higher than that of rice (1.432-1.464 g/c.c) one.

4.1.3- Molecular weight of constituent polymers Both the low angle Laser Light Scattering Techniques [63] and the ultracentrifugation [64] can be used to determine the average molecular weights of starch constituent polymers. The latter can also be estimated from the total carbohydrate content and the number of reducing end groups. Photometry, periodate oxidation, polarimetry, osmometry, radiometry and enzyme analysis [ 65 ] besides the most sensitive methods which involves the reduction of ferricyanide ions [66] can be utilized to measure the number of reducing end groups.

Amylopectin consists of three chain types; C-chains which have reducing ends, B-chains which are linked to two or more other chains, and A-chains linked to only one other chain by their reducing ends [67]. The distribution of chain lengths can also be determined by gel filteration or high performance liquid chromatography(HPLC)following debranching with isoamylase [68, 69]. Takeda et al. [44] concluded that sweet potato has a higher proportion of A-chains and short B-chains than has potato. Also, sweet potato amylose appears to have more branches per amylose molecule than that from cassava, potato, wheat or m6ize, and a higher molecular weight than maize, wheat and cassava but less than potato. This was the reason for the lower retrogradation of sweet potato amylose. The degree of polymerization and branching have substantial effect on the physicochemical properties of amylose and amylopectin [70].

4.1.4- Crystallinity : Zaslow [71] suggested the use of the X-ray diffracton to provide information about the orientation and crystallinity of the starch. X-ray diffraction technique can be used to differentiate between the native starches, to detect the changes in crystallinity during the physical and/or chemical modification [72]. Three different X-ray patterns known as (A), (B) and (C) were obtained for plant starches. Therefore, the crystalline nature of a starch can be defined by the X-ray diffraction peaks. [70, 73]. The crystalline pattern of cereals, tubers and both roots and seeds starches have A, B and C shape respectively. The (A) shape shows three strong peaks at 5.8, 5.2 and 3.8 Angestroms (A~), whereas (B) shape has a

Page 80: Instrumental

63

medium peaks at 1.58-16 A ~ in addition to three peaks, two at 4 and 3.7 A ~ and strong one at 5.16 A ~ The (C) crystalline pattern has the similar peaks of (A) pattern beside medium to strong one at 16 A ~ [70]. Hizukuri [74] demonstrated that mixtures of A- and B-type starches produced intermediate patterns (c-type). c-type pattern can be further divided into C., C~ and Cb depending on whether the pattern is closer to A or te B. Levels of crystallinity in granular starch can be determined by separating and integrating the areas under the crFstallin X-ray diffraction peaks [70].

Type B starches tend to have lower levels of crystallinity (15.28%)and lower gelatinization temperatures. Type A starches tend to have higher levels of crystallinity (33-45%) and higher gelatinization temperature. The latter temperatures increase with increasing amylose content of type A- starches [70].

Sweet potato starch has a variety x-ray pattern between C and A, in contrast to cereal starches such as wheat and corn which have A- type and potato which have a B-type pattern. [75, 76].

The heating of starch in excess of water causes a higher loss of crystallinity comparing with that happens in less of water [77]. on other hand, soaking of starch granules in water at room temperature has no effect in its crystalline structure, wh{le using a dilute lye, dimethyl sulfoxide and concentrated urea as a steeping medium lead to a loss in birefringence of starch at room temperature. [78]. Nearly the same results were reported by Bekheet [59]. She found that steeping in water and dilutedalkali led to slight changes in the crystalline structure of wheat starch. The same results were obtained when the wheat grain, were boiled for 5 min. before soaking in water. While, a marked damage in the crystalline structure of whear starch was observed after, soaking the 5 min. boiled grains in diluted alkali (Fig. 12). She attributed their results to the rearrangement of chains of amylose fraction. Cooking and drying of water and Lye soaked and unsoaked grains affected the crystalline pattern of wheat starch (Figs. 13 a,b,c and 14). This influence was varied according to cooking method and soaking medium. Generally, the changes in the crystalline structure was relatively slight when cooking was carried out in water for unsoaked and water soaked grains comparing with pressure and steam cooking methods especially for diluted lye soaked grains [59].

Abou-Samaha [43] used the general electric X-ray generator to study the changes in the orientation and the crystallinity of maize and rice strahces before and after 24 hrs of acid, 5 and 21 hrs of moist heat modification. Results in Figs. (15) and (16) show that both native maize and rice starches had (A) crystalline pattern. This shape was characterized with three strong peaks and 2-3 weak peaks. The interplanar distances of these peaks were differed slightly between the two types of starch. Acid modification

Page 81: Instrumental

64

AkKALi SLEEP

wATER

HAl IVE ~ " ,

I~ESSUI~E

WATER J

FIG (13 "a ) I-RAY 01FFAJCTION OF COOKED WttEA! S[ARCH

Page 82: Instrumental

65

PRESSUR~ j

51EAI4 j

' J ~ s ~ ~ ~" ~A,.~/ FICa | I~- b ) J -nJi'~ O|FT~ACTION OF W&TER STEEPED CO0~ED WHEAT STARCH

I~ESSURE

STEAM

FIO | l ) -C) X-P~Y OIFFRACTION OF ALKALI SlrEEPf[O COOKEO WHEAT STARCH

Page 83: Instrumental

66

MECHANIC AL Ol:~ I1'~ .

~ , nattve

F i g . ( 1 5 ) x-~o,. . . . . og . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , - - o ~ , : :

maize sla~cn

I~, ~ ~ 24 I ~ , 1%.

c - I~c~d mo~f, e0. 24 hrs 2% A

o

e= moist heateci 21 his . ~

\ , , j

Q I

~o ~s jo 2~ ~, I~ . to :~::r,cli,~ ,It:, ~" ~" ,,4ro~l

Fi~.~ . ( ~ 6 ) x - fay o'~'actog'3m~ o' na~,ve =.oa aria too,st neat mOO,heO .,cu

s:a,ct~

Page 84: Instrumental

67

either with 1 and 2% HCI the position of the three rice starches. While, th increase in the numbers Therefore the crystallin converted from A to AC sh et al [79] stated that th crystallinity type aft modification caused cleava amorphous regions and t

for 24 hrs caused slight changes in main strong peaks of maize and

e moist heat treatment led to an of the strong peaks to five.

e pattern of these starches was ape. On other hand, Biliaderis e cereal starches retained their A er acid modification. Acid ge of a few starch chains in the he water molecules replace the

obtained crystalline cavities. These changes gave only a sharp peaks. [79, 80]. Whistler and Paschall [55] reported that heating of starches in the presence of insufficient moisture gave a compact crystalline structure and water swelling resistance granules. Zobel [70] found that the modification of maize, rice and wheat starches with moist heat treatment gave crystalline pattern having V shape. The same author suggested that the complexing of amylose with fatty acids is behined this change.

4.1.5- Gelatinization :

4.1.5.1- Gelatinization Temperature: The term gelatinization is used to describe the swelling and hydration of starch granules or the melting of starch crystallites [70]. In many fooa processing operations such as baking of bread and cakes, extrusion of cereals products thickening and gelling of sauces and pie filling, the gelatinization of starch is required (81,82)

Despite of the fact that starch molecule is highly hydroxylated and very hydrophilic, but still insoluble in cold water. This is due to the presence and distribution of starch granules in network structure [83]. According to Kerr [14] heating an aqueous suspension of starch caused changes include the following three phases:

i -- Slowly and reversible water absorption. Through this stage a limit swelling was occurred without increase in viscosity and/or change in the granules shape.

_ With the increasing the temperature of the starch suspension to about 65 ~ In this stage, the granules are: a) Sudenly swell or increase many times in size due to

absorbing of a great amount of water.

b) Rapidly losing its birefringence and that usually associated with an increase in its viscosity.

_ With increasing the temperature, the starch granules become almost formless sacs, and substantial portion of its soluble component is leached out.

These changes give the swelling starch granules the

Page 85: Instrumental

68

ability to form a gel after cooling. Also, Donovan ~841 summarized the stimultaneous changes occurred ur ng gelat nization process as follows;

a) Uptake of heat. b) Loss of crystallinity associated with a loss of

birefringence and X-ray diffraction patterns. c) Hydration of starch followed by granule swelling and

increasing in suspension ciscosity. d) Lowering in relaxation time of water molecules as

measured by pulsed nuclear magnetic resonance.

Gelatinization may happen at room temperature by using saturated solutions of certain salts, such as calcium chloride or by alkalies, such as caustic soda solution. These agents break the hydrogen bonds and allow hydration of liberated hydroxyl groups. [42]. Cooking of starch for 70-90 sec under 30 pounds of pressure caused complete gelatinization for starch and gave grains without discoloration. [85]. According to Neufeld et al. [86], the main purpose of soaking is to introduce rapidly sufficient amount of moisture into the wheat kernel to help in the gelatinization of its starch during cooking. Moisture content of 37 to 40% after soaking was found to be adequate for complete gelatinization when cooking was done at 70 p.s.i., but moisture con~ent of 41% or more was necessary with cooking at 20 p.s.i. The data of Smith [87] indicated that soaking of wheat grains to reach around 45% moisture reduce the cooking time necessary for complete gelanization.

Generally, the gelatinization temperature is controlled not only by the water content but also by the presence of salts, sugars and other small molecules. A major factor controlling swelling is the strength of the internal structure of the granules. The stronger the internal molecular structure, the higher the temperature required for gelatinization. [88].

Granule size, amylose content, molecular weight crystalline pattern and the internal organization all affect gelatinization. [89].

The gelatinization temperature appears to be greater in sweet potato starch than in that of cassava, potato or wheat but similar to that of rice. [26].

4.1.5.2- Gelatinization Transition: Starch gelatinization may be described either in structural terms as a loss of macromolecular organization and order or as a swelling process which also has major theological effects. A number of methods, have been described to study the gelatinization transition of starch. The irreversible loss of birefringence, which can be observed conveniently using a Kofler hot-stage microscope. [90], is a well known method. These events may also be followed by observing the loss of X-ray crystallinity. [91]. Differential scanning calorimetry (DSC) can also be u~ed since gelatinization is

Page 86: Instrumental

69

an endothermic process reflecting the change of order within the granule. The temperatures associated with the onset, peak and end point of the endotherm are noted and the total enthalpy change ~ H calculated from the area under the thermogram peak. These parameters vary with variety, and also with the environmental conditions in which the plants are grown. [92]. Also gelatinization endotherm only appears when water in excess of 4 molecules per glucose unit was present. [93]. The loss of order within the granule permits staining reactions to take place with dyes such as Congo Red [94]. The interactions with iodine and with enzymes such as glucoamylase have also been suggested to monitor gelatinization. [95, 96].

The study of Wootton and Bamunuarachchi [97] on the gelatinization behavior of unmodified starch from different botanical sources and different types of modified wheat starch by DSC indicated that the values of the started gelatinization temperature (To) was 50, 70, and 57~ the peak temperature (Tp) was 68. 78 and 72~ and the final gelatinization temperature (Tc) was 86, 89 and 87~ for wheat, maize and potato starches respectively. The (~ H) values was 4.7, 4.3 and 6.6 cal/g for wheat, maize and potato starches respectively. The gelatinization endotherm of some types of starches was observed by Kujimiya et al. [98]. They stated that the peak temperature (Tp) was 65, 73, 72 and 65~ for potato, waxy maize, maize and wheat starches respectively. The enthalpy change after the gelatinization was 4.5, 3.8, 3.2 and 4.3 cal./g for potato, waxy maize, maize and wheat starches respectively. The temperature To, Tp, Tc and the enthalpy of the endotherms of 8-rice starches ranged from 55 to 67~C, from 61.7 to 74.2~C, from 103 to I04~C and from 2.68 to 3.23 cal./g, respectively [99]. The values of peak temperature (Tp) was 71.6~C and 63.5~ the enthalphy ( ~ H) was 2.42 and 1.94 cal./g for maize and wheat starches respectively. (i00]. The swelling of wheat starch started at 45-50~C and continued to 85~ The loss of birefringence and the reduction in gelatiniza- tion enthalpy were mainly attributed to the dissociation crystalline clusters of starch at 50-55~ The residual reduction of enthalpy could be contributed to the dissociation of the double helices of starch granules at 55-60~ [i01].

According to Abou-Samah [43] and as shown from Figs. (17 & 18) both native and modified maize and rice starches had only a single endotherm transition corresponding to the gelatinization process. The temperatures, To, Tp, Tc and the enthalpy (~ H) of this endotherm were differed according to the source of starch, method and time of modification. Generally, both native and modified rice starches had significantly higher transition temperatures, To, Tp, Tc and lower (~ H) than maize one. The modification process either with acid and/or moist heat treatment shifted the temperatures of gelatinization endotherm to relatively higher degrees. This effect was more pronouncea in case of

Page 87: Instrumental

70

Fig.

b- 0.,b hr c, I 5 his

,t= 3 hrs o- 6 hrs

I= t 2 hrs

0.75 h~

J= l.b hr K= 3 rVS L= 6 his m. 12 hrs n. 24 hrs

p , 5hr$ r,. t0 hrS

t- 21 hrs

#'rod moddiud

2%

|e 10 80 tO v)o jtR r io

Temperature oc

( 1 7 ) osc thermograms el nalive, aod and me,st heat modified ma,ze

starch. (march: water rat0o. 1:4. P,tting rate t0~

Fig.

~ fO

(18)

I'

,F

%

r

10 el) gO ',,OO t~O

Temperature Oc

D$C thermograms of natwe, acid and mOiSt heat moddJeO r,ce

s ta/~. (starch. water rat,o. 1 4. heating rate 10Oc/mm)

O- 0 75 hr c,, 1 5 his d= 3 hrS e= 6 his 1.1, 12 hrS n,, 24 his

p.md meddled

n,., 0 75 hr ,h, 1.5 hr

K,, 3 his

L- 6 hr5 m= 12 hrs

g= 24 hrs

p- 5hrS r= 10 his S,, 1,5 hrs t,, 21 hrs

2%

Page 88: Instrumental

7l

moist heat than acid modification, the enthalpy ( ~ H) was markedly decreased with increasing the time and concentration of acid modification process. While, moist heat modification led to an increase in~H. A polynomial relationship with a second order equation was observed between each of To, Tp, Tc, ~ H; and time of acid and moist heat modification process. Acid treatment of the starch selectively cleaves the amorphous regions of the starch granules. As a result of progressive hydrolysis, increasing either time and/or acid concentration, the non crystalline parts of the granules were increased, and a decrease in the

H of the obtained endotherm was noticed. In case of moist heat treatment a reduction in the intramolecular and spherulitic intermolecuiar ordering may be occurred. According to Whistler and Easchall [55] moist heat modification gained starches the compact crystalline structure. The results of Donovan et al. [102] showed that the range of the gelatinization temperature of moist heated starches was broadened. Also, two peaks of gelatinization endotherm may be noticed. Zobel [70] suggested that the complexing of amylose with fatty acids behind this change.

Bekheet [59] studied the effect of food processing on gelatinization of wheat starch. She found that steeping of wheat grains either in water and/or in diluted lye solution before and/or after 5 min. boiling reduced from the energy required for starch gelat~nization. She observed only single endotherm peak for gelatinization of unsoaked and water, lye and 5 min. boiled soaked wheat starches. The To, Tp, Tc of these peaks were ranged from 30 to 35, 70 to 75 and 115- 120~ The cooking and drying of the previous samples led to a significance high reduction in the peak area of the native, uncooked undried, endotherm peak starch. This is due to the irreversible damage occurred during heating, cooking and drying of starch.

4.1.6- Colour: Several methods are in use of the determination of colour in starch products, ranging from visual inspection to the use of a photometer. Lovibond tintometer is often used. The Tentative Standard Method ii- 18-57 is specifically devoted to determine colour at starch by Beckman Model B spectrophotometer equipped with the integrating sphere diffuse reflactant attachment, with beam- expending lenses and a blue sensitive photo-tube or equivalent equipment. The reflectance (%R) at 450 mu, 550 mu, and 600 mu. is measured with this instrument, and the calculations involved are;

Colour= log % R at 600 mu - Log % R at 450 mu. Brightnes = % R at 550 mu. Greyness = Z - Log % R at 550 mu.

In USA the Brice-Keene photometer is used to determine the photoelectric reflectance of starch samples, and express it as a % of whiteness of standard plate calibrated against

Page 89: Instrumental

72

pure precipitated magnesium oxide. In Japan, the Hunter reflectometer attached to a photoelectric colorimeter AKA No. 50 of the Kotaki Manufacturing Co., and the integrating sphere of the same company has beed used. [48].

4.2- Chemical Methods:

4.2.1- Water soluble materials: Determination of water solubles matter in starch gives an indication about the added materials, and the extent of conversion of starch and dextrin. The methods used for determining these matter depend on suspending the starch in water at a definite temperature and concentration then filtering and the filtrate is evaporated to dryness on a steam bath, dried to constant weight in an oven at I05~C and weighted.

4.2.2- Acidity and pH: Acidity o~ starch is chiefly related to the presence of amylo-phosphoric acid as hydrolysable salts and partly to the residues of S02 which used as a preservative, or proppionic and other organic acids formed by the controlled fermentation of carbphydrate during steeping. [48]. A complete picture could be obtained by determining the electrometric titration curve. According to Bekheet [59] steeping of grains in water and dilute alkali increased the pH of wheat starch from 5.69 to 5.73 and 5.81 respectively. On other hand, cooking and drying of these grains increase from pH to 6.1-6.2 and reduced the titratable acidity of wheat star, h.

4.2.3- Alkali-Labile value: Native starches, modified starches, and dextrin contain a portion of substances termed as alkali labile, which is readily acted as alkali. A good grade corn starch gives an alkali-labile value of about 22, tapioca starch 14, thin-boiling starch 60 and a yellow dextrine 20. [48].

4.2.4- Alkali-Number: It is used to estimate the relative hydrolytic degradation of starch or the number of reducing end groups in starch. It is related to the molecular weight and has no relation to viscosity or solubility of starch [19, 48].

Commercial corn and wheat starches have consistently higher alkali numbers than those ot common tuber starches. The alkali number varies from 5.3-6.9 for tapioca, 5.7-6.9 for potato, 6.7-7.5 for wheat and 9.8-12.1 for corn starches. [56].

4.2.5- Damaged starch grains: The method used for estimating the damaged starch grain depends on their more readily swell in cold water and digest with ~-amylase. The proportion of damaged starch gives some information about the treatment which starch has received during manufacture. It is affected the reheological properties of starch gel. [48].

Page 90: Instrumental

73

4.2.6- Reducing power: Schoch [19] suggested the use of t~a r �9 does not in en by samp~ power of ~~icy~i~em~~d to deEe~m~ ~e reduci

size, time of digestion and the amouht of oxidant. It aoes not give an idea about the modification degree of oxidized starches and/or those treated in granular state with acid. These types of modified starches are washed free from modified reagents. Such washing removes the water soluble reducing substances. [103].

El-Saadany et al. [104] found that gamma radiation hydrolyzed the rice starch molecules into small molecular weight units and increased its reducing power. The reducing power of commercial corn starch ranged from 7.7 to 11.6 Rcu. mg/g

Wankhede an~ Uma~evi [3~] s~u~i~ ~h~ Gbang~ in reducing power os pyrodextrins os ragi, wheat and rice at different intervals of time at 200~C. Their results indicated that reducing power increased with extending of heating time. Abou-Samaha [43] found that the reducing power of modified starches was significantly differed according to the source of starch, methods and conditions of modification. Generally, modified and unmodified rice starches had lower reducing power than maize one. Acid modified starches had significant higher reducing power than moist heated one. Reducing power increased with the raising of acid concentration and,extending the time of modiflcation A polynomial relationship of second order equatlons was found between this chemical property and moaification time.

Bekheet [59] studied the influence of food processing, steeping, cooking and drying, on the reducing power of wheat starch. She found that steeping of wheat grains either in water or in dilute alkali did not affect the reducing power of starch. While cooking and drying increased this value from 0.0 to 3.07-4.4 Rcu. mg/g. This was due to the thermal hydrolysis of the bonds of starch molecules during cooking and drying.

4.3- Functional and rheological methods:

4.3.1- Swelling power and solubility: When starch is heated in the presence of water, the individual granules swell and a portion of the starch dissolves in the surrounding aqueous medium. The degree of swelling and the amount of solubilization depend on the extent of chemical cross-bonding within the granules, the presence of non carbohydrate substances in starch such as lipids and/or phosphate, a high amylose content and the greater numbers of intermolecular bonds. [105].

Badenhuizen [106] reported that during heating of starch in water,parts of its molecules in amorphous regions are gradually liberated until the shortest linear chains become able to diffuse out the walls of sac shaped swollen starch granules. The latter granules consisted mainly of

Page 91: Instrumental

?4

branched molecules, amylopectin. According to Miller et al. [107] and French, [73] swelling starts in the least organized amorphous intercrystalline regions of the starch granules. This leads to extent a tension on the neighbouring crystallites and distorting them. With further heating, the double helical region of the amylopectin crystallites structure become an uncoiling and/or dissociate. However, the liberated side chains of the amylopectin hydrate and swell laterally to exert more stress on the remaining crystallites. Because of the starch molecules are unable to stretch longitudinally, it may have a tendency to contract to a random coil conformation. This may prevent starch swelling in the direction of molecular chains. While the increase of the molecular mobility with further hydration permits a redistribution of molecules which allow the smaller linear amylose molecules to diffuse out the swollen granules. However, further heating and hydration are weaken the structure and produces a sol. Bowler et al. [108] suggested that the swelling occurs essentially in the plane of two major axes of the granule and very little in its thickness direction. The swelling includes a radial expansion to form a flattened disc, followed by tangential expansion to produce a complex puckered granule.

Leach et al. [109] found that the maize and milo starches gave two stages'of swelling. This is an indication that there are two sets of bonding forces which relax at two different temperatures. Madamba et al. [ii0] found that sweet potato starch exhibited single stage swelling, which suggested the presence of uniform intermoiecular bonds. In contrast, Delpeach and Favier [i05] found a two stage swelling pattern for sweet potatoes starch, which suggested that this type of starch has a high degree of intermolecular bonds in its granules. Therefore, the swelling and solubility of this starch are less than those of potato and cassava but generally more than those of corn starches.

According to Abou-Samaha [43] the native maize starch had higher swelling power than rice starch. Modification process, especially with 2% HCI, reduced the swelling power. This reduction increased with extending the modification time. A polynomial relationshi~ with an equation of second order was observed between this property and the time of modification. Also native and modified maize starches were more soluble than that of rice one. Acid modification, especially with 2% HCl for longer periods gave more soluble starch than moist heat treatment. The relation between starch solubility, and modification time was either linear and/or polynomial. He attributed his results to the redistribution and/or partial hydrolysis in the starch molecules due to both acid and moist heat modification. These changes are behind the reduction of the ability of starch granules to swell and the increase of the solubility of modified starches. The same results were reported for moist heated starches of corn, potato, Parley, red millet,

Page 92: Instrumental

75

wheat and cassava as well as potato acid modified starches [80, I0~ iii, 112]. The changes in swelling and solubility of the starches after modlfication may be due to the changes occurred in the physical state of the amylose component of the native starch.

Bekheet (59] found that soaking of wheat grains either in water or diluted alkali before and after 5 min boiling gave starches having lower swelling capacity and less soluble comparing with native wheat starch. The decrease in both properties were more in starches of boiled lye soaked wheat grains than those of water soaked one. Also cooking and drying lowered from the swelling power and solubility of wheat starch. Hoseney et ai. [7~] reported that when starch was placed in water, it absorbed part of the water and swelled slightly. At room temperature, the process was reversible. At 50~ the internal structure of the wheat starch granules was altered. According to Tester and Morrison [i01], swelling of wheat begun at 45-50~C and continued to 85~C. At 50-55~C, loss of birefringence and a large decrease in gelatlnizatlon enthalpy occurred. These changes were attributed to dissociation of the crystalline clusters and the double helixes. Leaching of polysaccharides amylose and amylopectin from starch was found to be highly correlated with swelling factor. The formation of amylose lipid complexes inhibited the swelling.

4.3.2- Viscosity and consistency : The properties of starch dispersions in water and its pasting behavior are usually studies by observing changes in viscosity of starch systems [77, 113]

Kerr [114] suggested the determination of the viscosity of hot paste, cold paste and alkaline solution or fluidity test to evaluate the starch dispersing and pasting behavior. Generally, different instruments including the capillary, Stromer, Mac Micael, brookfield, the falling sphere. Brabender amylograph and corn industries viscometers can be used to estimate the viscosity of starch dispersions and pastes [48].

4.3.2.1- Viscos related to the ability viscosity of the s intermolecular interac molecular size and he [81]. According to Rad starches even after co primarily as colloidal presence of larger a granules. The swolle

ity : The intrinsic viscosity is of polymer molecules to increase the olvent in the absence of any tion. It is directly related to nce to the degree of polymerisation ley [48] the viscosity of unmodified nsiderable cooking are not considered

phenomenon, but may be due to the ggregates including undisintegrated n starch granules form a structure

including portion of liquid phase. This phase incrased the viscosity of native starch than of an acid and or moist heat treated one.

Abd-Allah et al. [ 75 ] stated that the relative viscosity of both maize and sorghum was reduced after

Page 93: Instrumental

76

modification either with acid and/or by oxidation. EI- Saadany et al. [104] found that the relative viscosity of rice starch was 2.328. Takeda et al. [44] showed that sweet potato amylose has a limiting viscosity higher than that of wheat but lower than that of cassava or Irish potato amylose. Also, sweet potato amylopectin has a lower limiting viscosity number than Irish potato amylopectin suggesting smaller or more spherical molecules. Abou-Samaha [43] found that native and modified maize starches had higher relative and inherent viscosities, lower fluidity, than rice one. Modification of starch, especially with 2% acid reduced the relative and inherent viscosities. This reduction increased with extending the modification time. A pol and red aft and after soaking either in water or dilute alkali, cooking drying the grains.

ynomial relationship was noticed between these properties time of modification. He attributed his results to the

uction in the ability of starch granules to aggregate er modification. According to Bekheet [59] the inherent

relative viscosities of wheat starch were decreased and

4.3.2.2- Paste characteristics: The viscosity of the paste of starch depends on the swelling of the granules, the percentage of t orientation of these concentration, heating t affect its viscosity [ii

When an aqueous su presumed that the amorp progressive hydration an network structure which and intact micelles.

he dissolved molecules and the molecules. Also, the type,

emperature, pH, and drying of starch 5]. spension of starch is heated, it is hous parts of the granules undergo d swelling. This gives an expanded is held together by the persistent This structure gives the swollen

granules their elastic properties and may be responsible for their pasting. [109]. Maximum swelling of granules and formation of a paste of wheat starch is obtained at water content more than 70% [116]. The starch paste consists of a mixture of starch and water as two phases. The discontinuous solid or semisolid phase usually forms from the swollen starch granules and nearly, all the water in this system is absorbed by the starch granules. The remaining is scarely sufficient for acting as lubricant between the moving particles. When the starch paste is subjected for a high pressure or a high stirring, the swollen particles are distorted or disrupted [43].

The Brabender amylograph provides a good method for defining these characteristics. It measures the changes in viscosity as a function of temperature and time. After gelatinization the viscosity increased because of granular swelling and the effects of soluble matter which are released from swollen granules through further heating or mechanical disruption. The temperature is usually raised at a rate of 1.5~ per min. until 95~ where it is held for a given length of time before the temperature is lowered to 50~ at the rate of 1.5oC per mi~.. and then held at 50~ for

Page 94: Instrumental

??

another given length of time. The first part of the Brabender Viscograms of starches describes the swelling of the starch granules which increased with the raising in temperature. While second part indicates the maximum consistency, when the granules become more highly swollen. The third part of these curves shows the decrease in the viscosity due to the deformation and the rupture of the swollen starch granules. The last part illustrates the setback that occurrs as a result of the orientation of the amylose molecules in a parallel fashion to form aggregates of low solubility. The following important characteristics can be observed from these curve:

i- The highest or peak viscosity (p) which is showed a noticeable irrespective trend with temperature applied. This property is important during preparation of the usable starch paste.

2- The viscosity of the paste (M) when it reaches the temperature of 95~

3- The stability or breakdowgn of the hot paste viscosity (H) after cooking for i0 min. at 95~C.

4- The viscosity of the cooked paste after cooling down to 50~C or the setback viscosity (C). It is a measure of the thickening produced by cooling.

5- The breakdown or stability ratio (H/P) and the setback or thickening ratio (C/P).

The pasting viscosities are depended on preparation method, impurities, concentration and variety of starch. [117]. In 1991, Abou-Samaha [43] studied the influence of acid and moist heat modification on the reheological behaviour, paste characteristics, of both native maize and rice starches using the Brabender visco/amylograph at a constant concentration, 10%. Figs. (19, 20 & 21) illustrate the complete cooking and cooling curves obtained from Brenbender instrument for both native and modified maize and rice starches. The data in these figs indicate that:

1- Generall, the rheological properties of native and modified rice starches, namely P,M,H,C, H/P and C/P values, were lesser than those of maize one. This means that the swelling of rice starch is much less than maize. Hence its granules stay more rigid and are embeded in more fluid. Therefore, it is expected that a lesser quantity of rice starch granules breakage are occurred during cooking comparing with maize granules. Accordingly, the rice starch paste are built up from entire granules or well organized parts of granules, low starch is present in the interstitial liquid. So, the particles are easier to separate. Therefore, the

Page 95: Instrumental

78

"- , , ' ; 7 ~.' B i . . , + l l �9

v, +' j

vISCOS,~y ol ma,ze slarc~ (conc( r ,,~,o~ ~ o%,

Fig.

, ,- o �9 ,,,,or,,,,+

" ~ 0 ~ I+~ ~ ' ~

r ;

qJ t

( 2 0 ) Eflec~ ol i c ~ mo~,hcal,on (A ~o and B. 2/ .) On tr~e arny,og,ap,

viscosity of rice $1arcn (concer~lrahOrl 10e~)

i B

1 , . f ~ f

i,,.,, p...,,

siarches (conconiralon 10%)

Page 96: Instrumental

79

rice starch paste is described as shorter than of maize and on cooling more fragments control the nature of the retrogradation process.

_ Modification either with acid and/or moist heat treatment reduced the paste characteristics of native starches. This effect was more pronounced with extending the modification time. Also, the rate of reduction in these parameters was more noticeable in case of acid modified, especially when 2% HCl was used for up to 3 hrs, than that of moist heated starch. This effect may be due to the naked reduction in the swelling power and the increasing in the solubility of starch granules.

_ It is interested to notice that moist heat treatment for 21 hrs at II0oC, gave starch pastes with higher maximum cooking and setback viscosities than that obtained after acid modification with 1 or 2% HCl for up to 1 hr. This is an indication that a partial destruction may be occurred in starch granules, especially amylose fraction, after moist heat treatment. These samples showed a high stability during cooking of starch. He attributed the paste stability behaviour to a conversion of amorphous amylose to helical form, which can acts as a weak centers of crystallinity for stabilizing the starch granules. On the other hand, the acid modification up 3 hrs, especially with 2% acid destroyed the structure of the granules. This destruction affected the paste characteristics, especially at higher temperatures. The characteristics of maize disappeared after with 1 and 2% HC modified starches structure either t In conclusion, the a good stability, higher consistenc such products a especially when t left as fully in modified starch es hrs can be suggest to penetrate fiber

and rice starch pastes were completely 12 and 24 hrs of acid modification

i. This means that such type of gave solutions almost free of

hrough heating and or after cooling. moist heat modified starches showed setback paste characteristic, and

y than acid modified one. Therefore, re appreciated in food industry he swollen starch granules must be tact as possible. While the acid pecially that treated for more than 3 ed to use in industrial applications , e.g. paper and textile industries.

Seog et al. [118] found no peak viscosity was obtained with 4-6%- (w/v) sweet potato starch suspensions. While a moderate peak viscosity during cooking and a high set back on cooling with a starch suspension of 7% (w/v).

4.3.2.3- Alkaline fluidity: It estimates the volume of starch paste which flows in 7 seconds. It uses to compare between the acid modified s~arcnes [1i8, 1i9]. The

Page 97: Instrumental

80

products have high alkalinie fluidity having low thickening power and~ viscosity..[120]" Seib and Maningat [121] observed a strong correlatlon between the alkaline fluidit and the Vi~O~! y Of ~a~h Abou-~amaha [433 s hat the alkaline fluidity os the acid modis rice starch was higher ~han that os maize one. In both sources of starch, the value of this characteristic increased with raising the HCl concentration and extending the time of modification. A polynomial relationship with second and third order equations was found between the alkaline fluidity and an acid modification time. According to Bekheet [59] steeping of wheat grains in water or dilute alkali slightly reduced the alkaline fluidity of its starch. While cooking and drying caused a marked decrease in this property. She attributed these results s the irreverslble damage occurred in starch during heating.

4.3.2.4- Visco elastic properties of starch gels The characterization of starch paste by viscometry such as amylograph and corn industries viscometers may cause a destruction of the starch system and do not cover all the required informations to characterize the starch structure [122]. Therefore, Evans and Haisman [123] and Wong and Lelievre [124] suggested the determination of the mechanical behaviour or the viscous and elastic parameters of starches either in native state or ~ during and after modification and gelatinization. The starch paste at a concentration > 5% showed a certain amount of rigidity due to swelling and the ability of granule fragments to act as cross-linking sites for the polymeric exudate of the paste. This is an indication that some of the applied stress is not dissipated, but is stored. [115, 122, 125]. Therefore, the pastes have viscoelastic characteristics. In this case, it is possible to resolve the stress in terms of an in-phase component and out-phase term related by the phase angle between the sinusoidal functions. This dynamic rheological measurement can be followed by two parameters, the storage modules (G ~) and the loss modules (G ~) respectively. [126]. These properties can be estimated by subjecting the gels to an oscillating strain, and the visco-elastic parameters (G' and G") were extracted by comparing the strain with the resultant oscillating stress. (127]. Bell [126] suggested the use of the dynamic mechanical testing technique for determining these properties. In this technique the strain amplitude and frequency can be independently controlled. By this way, the changes in the structure by building up and/or breaking down, recovery characteristics, can be measured in real time and continously.

Abou-Samaha [43] studied the influence of acid and moist heat modification on the visco-elastic behaviour of both native and modified maize and rice starch gels using the Rhe-tech International Rheometer. The range of frequency was 0.01-0.5 HZ and amplitude was 0.01-0.i mNm. The storage modules (G') , the loss modulus (G") and tan delta (G"/G)

Page 98: Instrumental

8!

were calculated. The obtained data were illustrated in Fig. (22). The changes in G' (storage modulus) and G" (loss modulus) with the concentration as a function of frequency and amplitude are shown in Fig. (22). The results indicate that at a concentration of 5% of maize and rice starches, both G'and G" are highly frequency dependent. The values of G" are higher than of G over all the measuring ranges of frequency and strain. This is an indication that at this concentration, rice starch had almost, the characteristics of a viscous system. Increasing the concentration to 7.5 or 10% w/v was associated with an increase in G, elastic properties. The starch paste at a concentration > 5% showed a certain amount of rigidity due to swelling and the ability of granule fragments to act as cross-linking sites for the polymeric exudate of the paste. [115, 125]. In this case, it is possible to resolve the stress in terms of an inphase component and out-phase term related by the phase angle between the sinusoidal functions.

Increasing the concentration to 7.5 or 10% (w/v) was associated with an increase in G (elastic character) and a decrease in Tan delta. This is an indication that at these concentrations a gel like structure can De obtained. In this case the G was almost frequency independent. Generally these changes in the theological characteristics were based on the concentration at which the starch granules fill the total volume of the system. Evans and Haisman [123] and Eliasson [115] reported the same conclusion. According to their results the increasing of the concentrations than 2.8, 2.5 and 3.8% for maize, potato and wheat respectively was associated with an increase in the elasticity. This increase was due to the granule-granule interaction. The diagrams in Fig. (23) illustrates that acid modified starches gave weaker gels comparing with the native ones. Therefore the gels of acid modified starches had low values of G , G" and a high over all value of tan delta. This effect was markedly observed with increasing acid concentration from 1 to 2% and extending the contact time between acid and starch. The reduction in G' and G" values may be attributed to the disintegration occurred in the amorphous regions of starch granules during acid treatment. This led to weak the structure and also to reduce the swelling power of the starch granu• These changes had a negative effect on the paste characteristics. Generally the results also showed that modlfication with acid up to 6 hrs gave a very weak gel even at a concentration of 10%.

Also, the data in Figs. (24 & 25) reveal that moist heat treatment of rice starch had nearly the same effect of acid modification. It reduced the value of G (elastic character), G" (viscous character) and gave weak gel. The same observation was noticed in case of maize starch after treated with a moist heat, except that G" slightly increase. In both sources of starch the tan delta (G"/G) was higher after the treatment. This effect was increased with extending the time of moist heat treatment.

Page 99: Instrumental

82

B

.~---'-" ..... jr._ ..,%"

, - - - - -~ . "".. . .

D i ~ ~ , , ~,-, _

l

~ + ~ . . % , .-: . . . . . . . .

C

i . . . . . . . . . . . . : - - - - - - ~ Z '

' j

;'i J -" : .... ~ [,/'/~'5/

I+ h

, . . . . J n . . . . ~ , & . - ~ . ,

J . . - " ~ ! " ' " "

+

F i g ( 2 2 ) +"'~ o, ....... , ..... c, a~ c," o . . . . ~ ......... t^ u, ,,,',o aml~,UOe (8.0) sweep ot ma,ze anti nco slarcn gels

;oom I mo~+ + . o ' I ,,.4

i r " , . , ~ ' - . . . . . .~ , ,

" . . . ) . .

l ++r long d + x~uu~ .

""... "" ,~ ' :g,,;, .-, i : o . , ';. D

' k " - . i

I

l lm~Iilu0e (~,~) sweep o| ma,z@ anO rice $1atr eel (cOncunlrahon

~0"/.)

+.._. 'q b : ..... o ,+, " ' - ~ . . , . _ . - - . , -~e . . . . . . . . .

101~,

- ~ - ~ . . . . ~ ~, r

~ . o + , o ~ .,. . , t ,,+ :

F ~ g �9 ( 2 4 ) ~ " ~ o' ,,,o,m ,+ . . . . . , . . . . . . . . . G .+o o" ~ . . . . ~ ....... �9 . . . .

anO ampl~luOe (b) sweep OV mmze ancI r~c~ sla'chu~

,31

" l

.27

Q+,

41

,0G

03

B "'I A o ,,,~o~1+ o , , , - ~ , , i r , '

A, " """ I~ . , a 1 ~.~/ 1" ,, ~/ , ' "

. ] .~ .I~

~ s ~o ~ ~ m"-';4 ) ~i ~ ' ;+ I ,~. ""

F i g �9 ( 2 5 ) E , , ~ of aoo IA) ...o ~o,~, . . . . <oi ~o0,,,r . . . . . , .o o ..... (G'IO') Ol ma, ze ancl tic6 $1atCh i~ll$ {concenlralion ~g-l~)

Page 100: Instrumental

83

4.3.3- Gel conslstency ano retrograoatlon: i~ is Known ~na~ wnen mo~e conce~ra~e~ past~s or cer~aln s~arc~es s~ano at room ~emp ranure or a ew no rs, ~ney set to rlglo gels The s~rengtn of gels oepenas on ~ne ~ime o~ se~tlng, the temperature a~ w~Ich ~ney are storeo an~ ~es~eo, ~ne Olmenslon o~ ~ne mould ano solnetlmes on ~ne nature o~ ~ne surface. The o~taineo gels develop ~neir structure by retrogradatlon. Thls galns the ge• s~ructure a certaln rigidity, eiastlc properties, ano reslstance against stress. The main force in the gei s~ructure is 0ue ~0 ire volume of the remnants of granule fragments in the warm paste. These serve as a framework for crystallization during coo~ing an0 around them the starch solution is able to retrograde to give a gel. Also, a certain minimum degree of swelling of the starch granules is necessarily for a coherent gel. When swelling is too low, a suspension of more or less swollen particles will resui~ ano the available water is not fully immobilized. This leads to lose water leaving a more concentrated gel during cooling. This process is called syneresis, the exude some of the water absorbed on pasting during cooling period. This situation may be further complicated where the starch granules are ruptured by shearing or other methods of thermal or mechanical damage. [128]. Further changes occur on storage, involving recrystallisation or retrogradation of the polymer chains. Retrogradation is affected by the amylose and amylopectin concentrations, the presence of other molecules such as sugars, salts and emulsifiers, molecular size, temperature, pH and other non starch components. [129].

According to Del Rosario and Pontiveros [129] the sweet potato starch retrograded more slowly than wheat, corn and cassava starches. This is the reason for the observation that bread containing sweet potato flour as a substituent staled at a slower rate than other breads. The results of the study of Rasper [130] on the changes in gel consistency of different starch gels over 7 days storage using the FIRA, Jelly Tester were:

Starch source Concentration Consistency in (g/450 ml) milliliters

1 day 4 days 7 days

Sweet potato Maize Cassava Xanthosoma Colocasia

26 8.5 10.5 12.5 34 10.5 17.0 14.8 25 Too low for measurment 32 16.3 18.7 20.5 25 2.7 3.6 2.9

Radley [ 48 ] stated that starch gels increased in strength rapidly during the first i0 hrs. Slight changes in strength of gels are occurred after 18 to 24 hrs. Creda and Wosiaki [131] found that the lost water of maize starch gel

Page 101: Instrumental

84

was 41.6% after 7 days of storage at 4=C. Hoover and found that st~rcht~l t~r~atat ~5~ 4h~d $osulki ~132~f syneresls , �9 lower va ue , los wa ke

This may be due to the low klnetl~ energy of seg~entai aotion 0s starch chains at -15~ than at -4~

Abou-Samaha [43] studied the syneresis property os gels prepared from native and modified maize and rice starches during storage at 2 and -18~ for different aged periods, 2- 16 days. He found that the syneresis exudated water, was higher in the gel of native and modified maize starches than of rice. Modification process e~ither with acid and/or either moist heat treatment increased the syneresis. This e~s was increased with the extending of modification time. A polynomial relationship was obtained between the synthesis ahd ~odis time. The level of the exudated water was higher when the starch gels wer~ kept at -18~C than at 2~c and also with extending os the gel age. A polynomial relationship was observed between the exudate water and modiflcation time. He supposed that the changes in exudate water during setting the gels at -18~ lowered its ability to bind water leading to increase of syneresis values than that at- 2~ The storing at -18~C may be affected the retrogradation of starch by rearrangement of starch molecules to be less branched or less differed.

4.3.4- Water bindiag cap:Jcity (WBC): It estimates the ability of starch to bind water. Because there are different methods to determine the WBC of starch, the values of this property are varied between researchers. [133]. According to Mac Arthur and D'appolonia [134] the WBC of wheat, oat and legume starches differed from 83 to 107; 85 to 87 and 78.2 to 92.4% respectively. Dreher et al. [135] found that the pindak be~n and pinto bean starches had 88.7 and 98.5% WBC respectively. According to Abd Allah et al. [75] the WBC of the starch of yellow maize, sorghum (Olza 3), sorghum (Giza 114), sordan (79) and millet was 98, 68.15, 79.16, 71.14 and 89.16% respectively. The value for sweet potato ranged from 66.3 to 211.6%. In general, tuberous starches have higher WBCs than those of cereal origin. Also, this property is higher in sweet potato starch than potato (93%) and cassava (72-92%) starches. [26].

The moist heat treatment of wheat and potato starches increased the watert binding capacity from 89.1 to 182.6% and from 102 to 108.7% respectively [136]. The same observations were reported by Donovan et al. [102] for the WBC of potato, barley, red millet and cassava starches after the moist heat treatment. Mok and Dick [137] stated that the hydroxyl group are the water binding sites of starch molecules. Boiling may increase these groups and consequently the WBC of starch.

Abou-Samah [43] found that native and modified rice starches had higher levels of WBC than maize. Also, the moist heated starch had higher levels of WBC comparing with

Page 102: Instrumental

85

acid modified one. A strong positive correlation was found between the WBC and time of modification A ~olynomial relationship with third order equation was found b_tween the WBC and time of modification. He attributed his results to the rearrangement of the starch molecules especially the amylose fraction in addition to the partial hydrolysis during the moist heat and acid modification treatments. In 1992, Bekheet showed that cooking and drying of water and diluted lye steeped wheat grains increased the WBC of their starches.

4.4- Nutritional Methods: It is known that starch can be easily digested by

monogastric animals first by action of salivary and pancreatic alpha amylase to produce mainly maltose and alpha limit dextrins, and second by the action of intestinal brush border glucosidase to produce glucose [138].

The enzymes catalyzing starch digestion included;

i _ -amylaser, which attack only the internalgZol,4 links in starch chains randomly to form dextins. The latter is hydrolyzed first to dextrins and finally to maltose. [139].

_ B-amylase, which attack ~-1,4 links of starch molecules starting from the hon reducing ends. Also, it can split off maltose units until 1,6 or 1,3 branching points are reached. This type of endwise action permits complete digestion of pure linear amylose and permits the removal of the external branches of amylopectin. [138].

_ Debranching enzymes: R-enzyme or 1,6 glucosidase can breaks the 1,6 links and that allows the B-amylase to continue its action [140].

_ Amyloglucosidases: It produces by certain types of molds, namely Aspergillus ni_~r A ysami and Rhiz0pus telemark. It is able to hydrolyse starch to glucose units as an end product of the digesta. Also, these enzymes remove glucose stepwisly from the ends of the starch chains [141].

_ Phosphorylase ~ In the presence of inorganic phosphate, it transfers glucose from the non reducing chain ends of starch to form glucose-l-phosphate. The action of this enzyme is inhibited by the presence of 1,6 links. [142].

The degree of amylolysis is dependent on the source, method of preparation, physical and chemical propertries of starch. [143]. Both Leach and Schoch [144] and Sandstedt et al. [141] attributed the variations in starch digestibility to the following:

Page 103: Instrumental

86

i _ The differences in the structure of starch due to the variations in the nature of the bonding between its molecules.

_ The differences in the hydrogen bonds among the outer layers of the starch granules.

Uncooked root and tuber starches were less susceptible to amylolysis than the uncooked cereals starches. [145]. According to Sugimoto et al. [146] and Dreher et al. [138] the uncooked starches can be divided into three groups according to their susceptibility to the amylolysis enzymes as follows:

(a)

(b)

(c)

The least digestible starches, which include potato, canna, arrow root, sago palm, amylomaize and banana s~arches. The intermediately digestible starches, which include sweet potato and various legumes starches.

The most digestible starches which include wheat, normal maize, waxy maize, rice and cassava starches.

The modification process affected the digestibility of starch. The in-vitro digestibility of gelatinized hydroxypropyl starch by pancreatic was decreased with the increase in the degree of' propyl substitution. The forming of the hydroxypropyl glucopyranose molecules during the modification process prevents the hydrolysis of adjacent 0([-1,4 glucosidic bonds by these enzymes. [147, 148]. The same observation was reported for the acetylated starches. [149].

The results of Wootton and Chaudhry [150] indicated that in-vitro digestibility of substituted starches by hydroxypropylation was more lower than the cross-linked one. The combination of both techniques, substitution and cross- linking, for modification had an accumulative effect in reducing starch digestibility. The study of Fanco et al. [151] showed that the large starch granules were more susceptible to,C-amylases and anyloglucosidase enzymes than small one.

Abou-Samaha [43] found that the in-vitro digestibility of native and modified maize starches was ~igher than that of rice. Modification of starch, especially with acid improved the starch digestibility. Also, this effect was increased with extending the modification time.

The domestic processing and cooking treatments improved the starch digestibility. Autoclaving was the most effective method of increasing starch digestibility of pulses and wheat, followed by sprouting, cooking of soaked seeds, cooking of unsoaked seeds, cooking of sprounts and soaking. These treatments reduced the level of amylase inhibitors which may be responsible for the increase in starch digestibility of processed and cooked legume grains. Also the gelatinization process allows for more rapid attack of

Page 104: Instrumental

87

starch granules by digestive enzymes. [59, 152]. The raw ~otato and high amy lose starches were less digestible and

ovided lower growth response than the other cereal and legume starches. [149].

4.5- Microbiological Methods: Tanner [153] examined the flat sour spores, thermophilic anaerobic and sulfide spoilage organisms in commercial starch samples. It was found that the number of the flat sour spores ranged from 131 to 193 per grain. About 50% and 6 to 30% of the samples had thermophilic bacteria and sulphide spoilage organisms respectively. The tos bacterial count varied from 65 to 3.17xi06 per gram in commercial starch. [154]. In Egypt, the samples of commercial rice starches were free from the gas producing, coliform bacteria and contained relatively high count of flat sour spores. [62]. Abou- Samaha [43] found that the flat sour bacteria spores (F.S.S.) were higher and total viable count bacteria (T.V.C.) was lower in native and modified rice than maize starch. Modification of starches either with acid and/or moist heat treatment, reduced the T.V.C. and F.S.S. This effect was more noticeable in case of moist heated starch than acid modified one. Also, this effect increased with extending the modification time.

5- Starch Modification ~ Methods: Native starches are insoluble in water at room

temperature, highly resistance to enzymic hydrolysis and lack specific functional properties [3]. To achieve the desired characteristics from native starch, Vogel [155] suggested the using of chemicals, enzymes and/or combinations of them to modify it. The modified starch products can be used according to their functional characteristics as thickening, gelling and binding agents in a variety of food such as canned and frozen puddings, fruit pie fillings, gravies, whipped topping and candies [156]. The International Organization for Standardization has been defined the modified starch as a native one after treating with physical, chemical or biochemical means to alter one or more of its original physical and/or chemical properties. This definition includes, pregelatinization, moist heat, oxidize and substitute starches. J48]. Modified starches are considered toxicologically safe and may be used in foods without limitations or restrictions. [149] .

5.1- Hydrolysed starches: 5.1.1- Acid thinning starch: Acid modified starch

is defined as a starch materials in the form of superficially unchanged granules. [157i. It is prepared Dy the action of acid on the aqueous starch suspension at sub gelatinization temperature and characterized by less hot paste viscosity, high reducing value, low iodine affinity, less granule swelling, high gelatinization temperature and low molecular weight. [69].

Page 105: Instrumental

88

The first preparation of an acid modified or thin- boiling starch was in 1886 by Lintiner and was known as Lintiner starch. The Lintiner method has been adopted as a standard procedure in which the native starch is treated by hydrochloric acid (7.5%) at room temperature for 7 days or at 40~C for 3 days. Shopmeyer and Felton [158] used the waxy maize to prepare an acid modified starch having 62 fluidity. He was treated a slury of 22 ~ Baume maize starch with sulfuric acid at a temperature of 48-55~C for 5 hours. Lansky et al. [159] incubated a 40% maize starch slurries either in 0.07 or in 0.3 N of hydrochloric acid at 50~ for a period started from 2-16 hours and extended to 5-40 days to prepare different types of acid modified starches. In 1950 Kerr [14] prepared acid modified starch by treating the starch slurries with 0.1-0.2 N sulfuric acid at a temperature of 50-55~ until the desired fluidity was obtained. During this process the amylopectin chains in the amorphous intermicellar regions of the starch granules are clove and the large branched chains are extended from one crystalline micellar region to another one. [109]. During acid modification soluble sugars are generated but most of the starch remains in the granular form. The linear molecules produced during the hydrolysis are arranged into bundle form and are responsible for the set back of starch paste on cooling [157]. Buttrose [160] used the hydrochloric acid at 8% concentration and a temperature of 39~ for preparing acid modified starch from tabioca and other sources containing high amylose content. The obtained thin- boiling starches had the following characteristics,reduction in hot viscosity, retention of gel structure and high in an adhesiveness.

5.1.2- Dextrins: Caesar [161] suggested the spraying of the acid over the dry roasted starch to prepare modified product similar in its properties to that produced by wet acid process. This method also causes a random cleavage of linkages along the starch molecule, producing dextrins differ than that of an acid thinned starches, It contains more water soluble solids, formed through the dry roasting process, light-tan to yellow colour, very low viscosity, high solubility and may or may not form gel, according to the degree of dextrinization, comparing with acid thinned one. [9].

5.2- Cross-linked starch: The treating of native starches with di-or polyfunctional reagents, the cross linking was occurred. These reagents will react with starch molecules at selected hydroxyl groups and create a cross bond between two starch molecular chains. Commonly used reagents are adipic acid, epichlorohydrin, phosphorus oxychloride and trimetaphosphate. These types of modified starches are high in molecular weight ~han native one. It can be used when a stable nigh viscosiny starch paste are needed, especially at prolonged severe heat treatment, shear

Page 106: Instrumental

89

force and/or low pH. [162, 163]. The method of preparing these products is based on treating the a~ueous alkaline starch suspenslon at 20-50~ with a cross-li k reagent at a level of 0.005-0.1% for the proper time. The treated suspension are filtered washd and dried. Generally, this process causes a drastic changes in starch characteristics. It increase the temperature of hydration, the stability under acidic conditions, both heat tolerance and shearing resistance of starch [139, 162]. Cross-linked starches are used by foods that heated for an extended time or subjected to high shear. It does not show substantial refrigeration or freezing stability. Therefore, it can De used in high acid food systems such as sauces os pizza, spaghetti, cheese, barbeque and hot filled systems such as pie fillings and bakery glazes in addition to a specially processed products such as puddings. [9].

5.3- Substituted starch: The substitution reactions introduce monofunctional group at the hydroxyl group of the starch molecule. Commonly used reagents are acetic acid, acetic anhydride, vinyl acetate, acetyl guanidine, acetyl phosphate and propylene oxide. [7]. Rutenberg and Solarek [162] suggested the using of starch acetate containing 0.5- 1.5% acetyl groups in food industry to provide sol stability, hydrophobic characteristics and good clarity for the food products,especial~y that storage at low temperature Substituted starches had the following characteristics; low temperature of hydration, good clarity, low syneresis and less freeze-thaw stability. Therefore, it is only suitable for preparing thick textured foods. It is not suitable to utilize in acid foods subjected to either high temperature and/or shear forces. [9].

Paschall [164] prepared sta::ch phosphate monoester by heating intimate blends of 10% moisture starch and orthophosphates at pH 5-6.5 for 0.5 to 6 hours at 120-160~C The obtained product haa a gooa paste clarity and high stability to retrogradation. The viscosity of this type of starch can be controlled by adjusting the amount of phosphate salts, reaction temperature,time and pH. Rutenberg and Solarek [162] suggested the using of sodium tripolyphosphate and urea with orthophosphates for preparing starch phosphate products.

5.4- Oxidized starch: Oxidized starch is manufactured by treating the starch slurry with alkaline sodium hypochlorite. This reaction causes a random cleavage of linkages along the starch molecule and bleaches starch colour. [162]. According to Hullinger [165] the oxidized starches have limited food functionality compared to other types of modified starches. It has low viscosity, low heat for hydration, less gelling properties and good dry powder flow. Thereforew, it can be used as dusting agents for such foods as marshmallow, chewing gum and in preparing the tablets of the pharmaceutical industry. [9].

Page 107: Instrumental

90

5.5- Moist-heat treated starches: All the above types of starches require heat to caused the granules to hydrate and swell. However, there are other two types of modified starches which can disperse in water systems and known as moist heated starches. These products can be classified according to the changes in the granule shape of native starches during the modification. The first type is substantially degraded during the manufacturing and known commercially as pregelatinized starch. The other type keeps its granular shape and referred to as cold water swell (CWS) or cooked up starch [9]. Sair [iii] suggested the adjustment of the starch moisture to a definite level to control the water absorption of the granules during heating in closed container. The moist heat treatment of 27% moisture content maize and potato starches for 16 hours at I05~C led to:

i- Slight changes in the microscopic appearance and reduction in the swelling power of potato starch, while no changes were observed rot tne maize starch.

2- The gelatinizat~on ~empera~ure of potato and maize starches.was increased from 61 to 80~C and 67 to 75~C respectively.

3- The viscosity was reduced as compared with the native one.

4- The X-ray crystalli~e pattern of potato starch was changed from (B) to (A) and (C) types. However, the modified maize starch had the same crystalline pattern (A) type of the native one.

The adjustment of moisture content of native maize, wheat and rice starches to 25% before heating for more than 3 hrs at 205~ are required to prepare moist heat modified starches. [27]. The moist heated starch can be produced by heating of wheat and potato starches of 18, 21, 24 and 27% moisture content for 16 hours at 100~ in a sealed container [136].

The work of Donovan et al. [102] on heating both wheat and potato starches of 27% moisture content for 16 hours at 100~ showed that:

i- No changes in the crys~aliinity pattern. A type, of wheat starch was noticed. While the (B) crystalline pattern of potato starch was changed to a i:i combination of (A) and (B) types. This indicated that such heat treatment caused a drastic alteration in the physical nature of potato granules.

2- The DSC results proved that ~he gelatinization range of these types of moist heated starches was broadened. Their gelatinization transition could be described as biphasic or two peaks in the endothermy region. These results may be attributed either to the presence of two types of starch granules structure or one kind but in two different environments.

Page 108: Instrumental

91

_ Generally, the final geiatinlzation temperature was

for both hincreasedwandeat antis poSWtato ~eliin~t~rches~ in. water was reduced

Hoseny [30] stated that, the (B) pattern of potato starch can be converted to A pattern by application of moist heat treatment. The commercial pregelatinized starch can be produced by heating the 40% starch slurry on drums. This process gave cooked starch dispersible in cold water with a less gelling power comparing with native starch used in bakery and extruded products. [15].

6- Food starch applications : The food induustry comprises one of the largest

consumer of starch and starch products [166]. In sugary confectionery, starch is used as a basic gelling ingredient, as a filler and as a moulding base. Different textures of gums, jellies and pastilles can be obtained by using various types of water binding gelling agents, principally arabic gum, modified starch, gelatine and pectin. Using of unmodified starch gives an unsatisfactory products having short texture starch can u Oxidized star in spaghetti oxidation. [I modified pota found that t higher water Galliard [166], each type following advantage and uses:

and weak body [9]. The cross-linked modified se as a food thickener in canned pie filling. ch can be used to produce a very tender gum and

dough as a carotene stabilizer to prevent 67]. Lorenz and Kulp [• used the moist heat to starch ~o prepare bread and CaKe. They he products containing modified starch had a absorption than the control. According to

of modified starches had the

i _

_

_

4 -

5-

Acid-thinned modified starch has low hot paste viscosity and, high gel viscosity. Therefore, it can be used in gums and jellies. Cross-linked starch increases the stability of frozen product, the pH and the shear resistance of the canned and frozen foods.

Esterified starch reduces the set-back and increases the clarity of frozen foods.

Oxiized starch increases the stability of frozen foods. Pregelatinized starch dissolves in cold water. So it can be used in preparing pie s coat.

According to the results of Abou-Samaha (43j the panelists did not find any variations between the sensory properties of yellow cake made ~rom 100% wheat flour and those prepared from 100% 6 and iu hrs moist heated of maize and 5 hr moist heated of rice starches. The leavening, general appearance, crust color, crumb colour, crumb texture, porous distribution and taste of cake were negatively affected when native and other's moist heated maize and rice starches were used.

Page 109: Instrumental

92

7- Conclusions: This review has shown that the physico-chemical

characteristics of starch are affected by variety, climate, sources, method of isolation and modification. More than one method are needed to cnaracterise and to select the starch of a given guali~y for a specific utilization.

8- REFERENCES: i- Lineback D.R. Bakers Digest. 1984; 58; 16. 2- Anonymous. Washington: Corn Refriners Assoc. Inc.1983. 3- Heckman E. in: Graham. D.G. ed. Westport: Avi. Pub.

Co. Inc. 1977; 464-499. 4- Kalichevisky M.T; Orford. P.D.; Ring. S.G.

Carbohydrate Res. 1990; 198; 49. 5- Moorthy S.N; Ramanujam T. Strarke. 1986; 36; 58. 6- O'Dell. J. In: Blansharu; Mitchell.; eds. London:

Butterworth. 1979, 171. 7- Biliaderis C.G.J. Agric. Food Chem. 1982; 30; 925. 8- Smith P.S. In: Lineback D.R.; Inglett G.E. eds.

Westport: AVI Pub. Co. Inc. 1982; 237-269. 9- Luallen T.E. Food Tech. 1985; 39; 59. i0- Anderson R.A. Cereal Chem. 1982; 59; 265. ii- Besso R. London: Applied Sci. Pub. LTD. 1976; 1-25. 12- Lii C.Y; Chang S.M. Proc. Natl Sci Counc Roc. 1978;

2; 146. 13- Takeda Y; Shitaozono T; Hizukuri S. Starke. 1988;

40; 51. 14- Kerr R.W. New York: Academic Press. 1950; 3-25. 15- Colonna P; Mercier C. Carbohydrate Res. 1984; 131;

233. 16- Banks S.W; Greenwood C.T., Muir. D.D. Starke. 1974;

26; 73. 17- Larson BI; Gilies K.A; Jenness R. Annal Chem. 1953;

25; 802. 18- McCready R.M; Hassid W.H. J. Amer. Chem. Soc. 1943;

65; 1154. 19- Schoch T.J. In" Whistler R.L. ed. New York: Academic

Press. 1964, 64-66. 20- Lineback D.R.U.K.: AACC-FMBRA Joint Course on Starch.

1990. 21- Kamal M.A.M. M.Sc. Thesis. Ain Shams Univ.;Egypt.

1963. 22- Kamal M.A.M, Rashed A.G.E. Hadidy. Z.A.F. Ain Shams

Univ., Egypt. Res. Bull. 1968; 155. 23- Juliano B.O. Food Reviews Internatinal. 1986; 1;423. 24- Munck L; Rexen F.; Haastrup L. Starke. 1988; 40; 81. 25- Schoch T.J. In: Whistler R.L. Paschall L.E., eds.

New York: Academic Press. 1967. 79-235. 26- Rickard J.E.; Asaoka. M; Blanshard J.M.V. Trop. Sci.

1991; 31; 189. 27- Fukui T; Nikuni Z. Agric. & Biolog. Chem. 1969; 33;

460. 28- French D. J. Jap. Soc. Starch Sci. 1972; 19; 8. 29- Robin J.P; Mercier. C; charbonniev ~; GuiiDo~. A.

Page 110: Instrumental

93

30-

31-

32-

33-

34- 35- 36- 37- 38- 39-

40-

41-

42- 43-

44-

45- 46- 47- 48-

49- 50-

51- 52-

53-

54- 55-

56- 57- 58- 59-

60-

61-

62-

63-

Cereal Chem. 1974; 51; 289. Chem1~~H~ of Cereal l~A~'_vv USA. American Association

Taylor T.C; Nelson J.M.J. Am. Chem. Soc. 1920; 42; 1738. Gracza R. In: Whistler R.L; Pascall A.F. New York:

Academic Press. 1965; 105-131. Ai-Bayati Lorenz K. Lebensmittel Wissenschaft

und Tech. l~Ib; ~; 163. Ei-Saied H.M. Starke. 1979; 31; 84. Wankhede D.B; Umadevi S. S~arke. 1982, 34, ~62. Soni O.; Agrawal A. Starke. 19~3; 35; 4. Swinkels. J.J.M. StarKe. • 37;1. Leelavathi K; ~ndrani D. $~arKe. i~77 39; 378. Tian S.J; RicKard J.E; Biansnard J.M. J. ~ci. Food

Agric. 1991, 57; 459. Reyes A.E; Briones V.P; Juiiano B.O. J. Agric. Food Chem. 1965; 13; 438. Briones V.P; Magbanva L.G; Juiiano B.O. Cereal Chem. 1968; 45; 351. Wallis T.E. London: Churchill. J.A. Ltd. 1967; 7-20.

Abou-Samaha O.R.M. Ph.D. Thesis, Alex. Univ., Alexandria, Egypt. 1991. Takeda Y; Tokunaga N.T; Takeda C; Hizukuri S. Starke. 1968; 38, 345. Rasper V. J. Sci. Food Agric. 1971; 22; 572. Goering K.J; Dehaas B. Cereal Chem. 1972; 49; 712. Kulp K. Cereal Chem. 1973; 50; 666. Radley J.A. London: Applied Sci. Publ. Ltd. 1976: 51- 107. Morrison W.R; Gadan H. J. Cereal Sci. 1987; 5; 263. Lopez O.P; Calvino E.C; (:astaneda J.G; Rivera R.M.

Starke. 1988; 40; ii. Schoch T.J; Maywald E.C. Anal. Chem. 1956; 28; 382. Mac-Masters M.M; Wold. M.J; Seckinger H.L.J. Agric. Food Chem. 1957; 5; 455.

Bechtel D.B; Zayas I, Kaieikan L. Pomerans. Y. Cereal Chem. 1990; 6'I; 59. Waldt L; Kehoe D. Food Tech. 1959; 13; i. Whistler R.L; Paschall E.F. New York. Acaaemlc Press. 1967; 65-78; 293-334. Dreher M.L; Berry J.W. StarKe. 1983; 35, 76. Bouwkamp J.C. (ed.). Boca Raton. FL.: CRC Press. 1985. Fuwa H; Sugimoto. Y; Tanaka M. Starke. 1978; 30; 186. Bekheet M.H. Ph.D Thesis, Alxandria University, Alex., Egypt. 1992. Smith P.S. In: Whistler R.L., ed. New York: Academic

Press. 1964; 41-42; 103-106. Hussein M; Ei-Waraki A.G; Saied. A; Toma. R.B;

Hassan Y.M. Ain Shams Univ., Egypt. Ann. Res. Bull. 1970, 157. Ei-Refai A.A. M.Sc. Thesis, Alex. Univ., Alexandria,

Egypt. 1970. Hizukuri S; Takagi T. Carbohydrate Res. 1984; 134; i.

Page 111: Instrumental

94

64-

65-

66- 67- 68- 69- 70- 71-

72- 73-

74- 75-

76- 77-

78-

79-

80- 81- 82-

83-

84- 85-

86-

87-

88- 89-

90-

91-

92-

93- 94-

95-

96- 97-

Kainuma K. In: Stumpf P.K; Conn. E.E. New York: Academic Press 1988; 141-180.

Hizukuri S; Takeda Y.; Yasuda M; Suzuki. A. Carbohydrate Res. 1981; 94; 205. Park J; Johnson M.J. Biol. Chem. 1949: 181; 149. Hizukuri S. Carbohydrate Res. 1985; 141; 295. Hizukuri S. Carbohydrate Res. 1986; 147; 342. Inouchi N; Glover. D.V; Fuwa H. Starke. 1987; 39; 259 Zobel H.F. Starke. 1988; 40; 44. Zaslow B. In: Whistler R.L; Paschall E.F. eds. New

York: Academic Press. 1965; 179-286. Zobel H.F; Methods in carbohydrate Chem. 1964; 4; 109. French D. In: Whistler R.L; Be-Miller J.N; Paschall. E.F. eds. New York. Academic Press 1984; 184. Hizukuri S. J. Jap. Soc. Starch Sci. 1969; 17; 73. Abd-Allah M.A; Foda Y.H; Mahmoud R.M; Abou-Arab A.A. Starke. 1987; 39; 9. Komiya T; Yamada T; Nara S. S~arKe. • 29; 308/ Ghiasi K; Hoseney R.C; Varriano- Mors~on. E. Cereal

Chem. 1982; 60; 5~. Hoseney R.C; L~nepack D.R; Seib P.A. BaKers Digest.

1983, July/August, 65. Biliaderis C.G; Grant D.R; Vose. J.R. Cereal Chem.

1981; 58; 502. Komiya T; Nara S. Starke. 1986, 38, 9. Olku J; Rha. C. Food~Chem. 1978; 3; 293. Biliaderis C.G; Maurice T.J; Vose J.R. J. Food Sci. 1980; 45; 1669. Leach H.W. In: Whistler R.L; Pascjoll E.F; eds. New York: Academic Press. 1965; 289-397. Donovan J.W. BiopoLymers. 1979; 18; 263. Brown A.H. In: Research Report of the Conference on Role of Wheat in World's Food. WRRL. Albany; Calif.; USA. 1962. Neufeld C.H.H; Weinstein N.E; Mecham D.K. Cereal Chem. 1957; 34; 360.

Smith P.S; Barta E.J; Lczar M.E. Food Tech. 1964; 18; 89. Hari P.K; Garye S; Gary S.K. StarKe. 1989; 41, 88. Banks W; Greenwood C.T. Edinburgh: Eainburgh Univ.

Press. 1975. Watson S.A. In: Whistler. R.L., ea. New YorK: Academic

Press. 1964, 240-242. Song E; Shi. M.S.; Hang Y.H. Han'guk Nanghwa

Hakhoechi. 1987; 3U: 242. Kitada Y; Sasaki M; Yamazoe Y; NaKazawa. H. Nippon

Shiko-kuhu Kogyo Gakkaishi. 19~; 35; 135. Duckworth R.B. J. Food Technology. 1971; 6; 317.

McMasters M.M. ~n" Whistler R.L; ed. New York" Academic Press. 1964, 4, 233-240.

Toyama T; Hizukuri S; Nikuni Z.J. Tech. Soc. Starch. 1966; 13, 69. Takeda Y; Hizukuri S. Cereal Chem. 1983; 60; 212. Wooton N; Bamunuarachchi. Starke. 1979; 31; 262.

Page 112: Instrumental

95

98- Kujimiya M; Donovan W; Wong k.f. StarKe. 1980; 32; 265.

99- Russel P.L; Juliano B.O. StarKe. i983; 35; 382. 100- Buck J.S; Walker C.E. StarKe. 1988; Yo, 35~. i01- Tester R.F;Morrison W.R. Cereal Chem. 1990; 67; 551. 102- Donovan J.W; Lorenz K.L; Kulp K. Cereal Chem. 1983;

60; 381. 103- Lyne F.A. In: Radley J.A; ed. London: Applied Sci.

Pub. LTD. 1976; 133-167. 104- El-Saadany R.M.A; Foda Y.H; El-Saadany F.M. Starke.

1979; 31; 230. 105- Delpeuch F; Favier J.C. Ann. Technol. Agric. 1980;

29; 53. 106- Badenhuizen N.P. In: Ruhland W. ed. Berlin, Germany:

Sprmger- Verlag 1958; 6; 137. 107- Miller B.S; Derby. P.I; Trimbo H.B. Starke. 1973; 32;

186. 108- Bowler P; Wiliams M.R; Angold R.E. Starke. 1980; 32;

186. 109- Leach H.W; Mc Cowen L.D; Schoch T.J. Cereal Chem.

1959; 36; 534. ii0- Madamba L.S.P; ~ustrillos A.R; San Pedro E.L. Pnilipp

Agric. 1975; 5~; 338. iii- Sair L. Cereal Chem. 1967; 44; ~. 112- Lorenz K; Kulp K. Cereal Chem. 19~2; 9~; 46. 113- Christianson D.D; Bagiey E.B. Cereal Chem. 19~; 60;

116. 114- Kerr R.W. New York: Academic Press. 1944. 115- Eliasson A.C.J. Texture Studies. 198%; 17; 25J. 116- Takahashi R; Ojima T. StarKe. i969; 21; 318. 117- Cereda M.P; Wosiacki G; Gonceicao. F.A. Cienc Technol

Aliment. 1985; 5; 61. 118- Seog H.M; Park Y.K; Nam Y.J; Shin D.H; Kim J.P.

Han'guk Naghwa Hokhoech, 1987; 20; 179. 119- Rohwer R.G; Klem R.E. In' Whistler R.L; Be-Miller.

I.N; Paschall E.F; eds. New York" Academic Press. 1984; 529-541.

120- Sing V; Zakiudin A.S. Starko . 1987; 39; 277. 121- Seib P.A; Maningat C.C.U.K: AACC-FMBRA Joint course

on starch. 1990. 122- Myers R.R; Knauss C.J; Hoffman R.D. J. Appl. Polymer

Sci. 1962; 6; 659. 123- Evans I.D; Haisman D.R. J. Texture Studies. 1979; i0;

347. 124- Wong R.B.K; Lelierre J. J. App. Polymer Sci. 1982;

27; 1433. 125- Ferry J.D. Chichester. John Wi• and Sons Inc. 1980;

1-55. 126- Bell A.E. In: Hadman T.M. ed. London: Elsevier

Applied Sci. 1989; 251-175. 127- Ross-Murphy S.B. In: Cnan H.W.S; ed. London:

Blackwell Scientific Publ. 198~; 13~-i99. 128- Mestres C; Colonna P, Bulean A. J. Cereal Sci. 1988;

7; 123.

Page 113: Instrumental

96

129- Del Rosario R.R; Pontiveros C.R. Starke. 1983; 35; 86.

130- Rasper V. J. Sci. Food Agric. 1969; 20; 165. 131- Cereda M.P; WosiacKi G. Starke. 1985; 37; 404. 132- Hoover R; Sosuiskki F. StarKe. 1985; 37, 397. 133- Rasper V; De Man J.M. Cereal Chem. 19~0; 57; 331. 134- Mac-Athur L.A; D'appolonia B.L. Cereal Chem. 1979;

56; 455. 135- Dreher M.L; Padmanaban G; Frazier A.R; J. Agric. Food

Chem. 1983; 31; 844. 136- Kulp K; Lorenz K. Cereal Chem. 19~i; 58; 46. 137- Mok C; Dick J.W. Cereal Chem. 1991; 68' 405. 138- Dreher M.L; Dreher C.J; Berry J.W. CRC. Critical Rev.

Food Sci.& Nutr. 1984; 20; 47. 139- Radley J.A. London: Champen and Hall Ltd. 1968; 247. 140- Sandstedt R.M. Cereal Sci. ~oday. 1965; i0; 305. 141- Sandstedt R.M. Straham D; Veda. S; Abbot R.L. Cereal

Chem. 1962; 39; 123. 142- Fleming S.E; Vose J.R; J. Nutr. 1979; 109; 2067. 143- Abbas I.R; Scheeres J.C; Berry J.G. Starke. 1987;

39; 280. 144- Leach H.W; Schoch T.J. Cereal Chem. 1961; 38; 34. 145- Sugimota Y; Takaya T; Fuwa H. J. Jap. Soc. Starh Sci.

1976; 23; 117. 146- Sugimota Y; Ohmish K; Takaya T; Fuwa H. J. Jap. Soc.

Starch Sci. 1979; 26~ 182. 147- Leegwater D.C; Luten J.M. Die StarKe. 1971; 23; 43U. 148- Wootton N; Chaudhry M.A. StarKe. ~979; 31; 224. 149- WHO. Tech. Rep. Ser. No. 439. WHO; Geneva. i974. 150- Wootton N; Chaudhry M.A. StarKe. • 33; i35. 151- Franco G.M.L; Preto S.J.~; Ciacco C.F; Tavares D.Q.

Starke. 1988; 4; 29. 152- Jood S; Chanhan B.M; Kapoor. A.C. J. Food Chem. 19~8;

30; 113. 153- Tanner F.W. USA: Garrad Press. 1994; 673-674. 154- Spicher G. Bortu. Geback. 1960; i~; 130. 155- Vogel W.F. Conserva. 1969; 18; i. 156- Hood L.F; Seirfried A.S; Meyer R. J. Food Sci. 1974;

39; 117. 157- Shildnech P; Smith C.E. In: Whistler R.L; Pascall E.F;

eds. New York: Academic Press. 1967; 217-234. 158- Shopmeyer H.H; Felton G.E. In: Radley J.A. ed. London;

Champan and Hall. 1943, 451. 159- Lansky S; Kooi. M. Schoch T.J. J. Amer. Chem. Soc.

1949; 71; 4066. 160- Buttrose M.S. Die Starke 1963; 14; 85. 161- Caesar G.V. In: Radley J.A. ed. London:

Hall Ltd. 1968; 282. 162- Rutenberg M.W; Solarek D. In: Whistler.

Champen and

Miller J.N; Paschail E.F; eds. New Press. 1984; 312-366.

163- Colas B. Lebensmi~el. Wissenscna~t 1986; 19; 308.

164- Paschall E.F. In: Wnis~ler ~.L. , ed. New YorK:

R.L; Be- York : Academic

und Technologie.

Page 114: Instrumental

97

Academic Press. 1964; 294. 165- Hullinger C H. In" Whistler R.L. ed. New York-

Academlc Fress. 1964, 313. 166- Galliard T. Chichester: John Wiley and Sons Inc. 1987. 167- Zusman S. Nahrung. 1985; 29; 905.

Page 115: Instrumental

This Page Intentionally Left Blank

Page 116: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 99

Specific methods for the analysis of identity and purity of functional food polysaccharides

Francisco M. Goycoolea a and Ioannis S. Chronakis b

a Research Center for Food and Development (C.I.A.D., A.C.), P.O. Box 1735, 83000 Hermosillo, Sonora, Mexico

b Physical Chemistry 1, Center for Chemistry and Chemical Engineering, Lund University P.O. Box 124, S-22 100 Lund, Sweeden

INTRODUCTION All foods with few exceptions contain biopolymers, namely polysaccharides and

proteins, occurring either as natural constituents of edible living tissues (e.g. connective tissue and muscle fibers in meat and fish, cell walls of fruits and vegetables, etc.) or as aid-agents intentionally added to manufactured food in order to increase sensory acceptability and physical stability. The term functional has been coined to the range of physico-chemical properties largely affected by polysaccharide and protein macromolecules in the architecture of foods, namely those related to one or more of the following:

�9 Generation and control of product rheology (e.g. viscoelastic and plastic properties, etc.)

�9 Melting and setting temperature of food gels * Water and fat binding capacity �9 Glass transition temperature �9 Crystallization inhibition . Surface activity (e.g. emulsions and foams formation and stabilization) . Thermodynamic properties, (e.g. heat capacity, heat stability, phase behavior, etc.) �9 Flavor encapsulation (e.g. spray drying, microencapsulation) �9 Sensory properties (e.g. texture, mouthfeel and flavor release)

Due to their ability to form colloidal aqueous solutions, functional polysaccharide gums are also referred to as hydrocolloids. The effectiveness of hydrocolloids to modify and/or control functional properties of foods is modulated by their molecular structure and conformation. The replacement of fat by modified starches in many new 'low fat' versions of foodstuffs in today's market place, is just an example of the huge commercial importance of hydrocolloids gmns in the engineering of new food products [ 1]. There is hardly any manufactured food or drink that does not contain a stabilizing hydrocolloid as a part of its formulation.

Page 117: Instrumental

100

There is a well established structure-function relationship underlying the individual behavior of different hydrocolloids. However, the great complexity of multi- component real foods, allow at present only limited understanding of the precise behavior of each of the individual pieces in the food system machinery. The choice of a functional additive is still largely done on an empirical basis. The main reason for this is because of the limited information available between structural parameters of the different functional hydrocolloids and key characteristics of commercial importance such as heat stability, thixotropy, shear viscosity, etc.. Once a given hydrocolloid(s) is set to perform successfully in the product, the manufacturer aims at a constant quality from the supplier of that ingredient. Quite often though, the food manufacturer does not even know about the nature of the purchased gums, since these are sold as commercial blends of two or more ingredients under trademark names (e.g. 'ice cream mix'). However, problems can arise for instance, when a change in supplier is made or a new different batch is received from the same supplier. Certainly, in many instances, it is the hydrocolloid producer the one who assists food companies with the expertise and understanding about the use of their products, since they must have a soundly based and detailed knowledge of the chemical and steric structure of the materials they deal with.

With the notable exception of gelatin, industrial hydrocolloids are all polysaccharides. These include starches and a fair number of different polysaccharide materials from plant, seaweeds and microbial (e.g. by use of controlled liquid fermentation) sources. It is also worthy of mention that the majority of functional food polysaccharides, digestible starches apart, belong to the non-digestible carbohydrate fraction of food (i.e. the dietary fiber) from the nutritional viewpoint, so many of the analytical tests provided here might be relevant to the analysis of the individual components of dietary fiber. Nevertheless, coverage of the current methods for the determination of dietary fiber as such, lays beyond the scope of this chapter.

The focus of this review is thus, on selected instrumental analytical methods, which can provide 'fmgerprints' of the free structure characteristics leading to the unambiguous identification of some industrial polysaccharides. First, an overview is presented on the different techniques and strategies available for analysis of polysaccharide primary structure, which is followed by a section on specific examples of different analytical problems found in food polysaccharides. The systems covered are: i) starch, iii) gum arabic, iv) alginate, and iv) carrageenan. A summary of analytical tests to identify the presence of hydrocolloid gums in foods, is also included as the final section of this review. Although the major structure features of each of the polysaccharide systems covered in the above examples and current analytical strategies to determine such features are outlined in this review, coverage by no means pretends to be exhaustive. The reader is also referred to excellent treatises on polysaccharide structure analysis [2, 3].

Page 118: Instrumental

I01

ANALYTICAL STRATEGIES

Carbohydrate Chemistry

For those readers unfamiliar with carbohydrate chemistry, a few brief concepts on primary structure and chain geometry are introduced here. The basic building block in all industrial polysaccharides is a 6-membered (pyranose) sugar ring, composed of five carbon atoms and one oxygen. In the projection shown in Fig. 1 carbon atoms are customary numbered clockwise from the ring oxygen, with C(6) lying outside the ring. The stable conformations of the pyranose ring are chair forms (4C1 and IC4) in which all bonds are fully staggered [4]. In the chair conformations, substituents at each carbon atom may be present in either equatorial locations, or in crowded axial positions above or below the ring. Hexose monosaccharides (sugars with 6 carbon atoms), are classified in two groups, according to the steric configuration at C(5), the position of ring closure. In the D series C(6) is equatorial in the 4C1 ring form, while in the mirror image L series (i.e. their enatiomers), the corresponding stable chair form is IC4. Out of the possible isomers given by the configurations at C(2), C(3) and C(4), only some of them occur in nature. In the stable ring form of glucose (4C~ for D and 1C4 for L) O(2), 0(3) and 0(4) are all equatorial; in mannose 0(2) is axial; in galactose 0(4) is axial; in gulose 0(3) and 0(4) are axial and in idose all three are axial. Configuration at C(1) is denoted as ~ when O(1) is axial and as 13 when O(1) is equatorial. O(1) is chemically different from the other pendant oxygens of the ring, since it forms part of a hemiacetal group with the ring oxygen, 0(5). Since all polysaccharides are composed of monosaccharide residues, the first consideration in describing the structure of the polysaccharide is the component units. Polysaccharides comprised by identical sugar units are called homopolysaccahrides (e.g. amylose and amylopectin in starch, cellulose); otherwise if sugar units of different kind occur together in the same structure is a heteropolysaccharide. Other than amylose and amylopectin most industrial polysaccharides are heteropolysaccharides. Heteropolysaccharides may have greater structural complexity, including the following type of arrangements: a) linear homopolymeric structures interrupted by insertion of residues of a different

type (e.g. pectin, carboxymethyl cellulose); b) regular alternating linear structures where two sugar units repeat periodically over

long stretches in the same skeleton (e.g. carrageenans and agarose); c) more complex linear repeats formed by more than two different alternating

sequences (e.g. gellan); d) linear structures in which two or more units are present in non-regular patterns (e.g.

konjac glucomannan); e) those in which one sugar unit is present in the main backbone and the other in the

sidechains (e.g. galactomannans); f) more complex periodic branched sequences (e.g. xanthan, which has a cellulosic

backbone with three-sugar (trisaccharide) sidechains on alternating residues).

Page 119: Instrumental

102

g) irregular, non-periodic, complex structures comprising several types of sugar units and sometimes non-polysaccharide appendages (proteins), often having dense branching (e.g. gum arabic).

H ~" CH20H 0

HO H

H

H H

OH

Figure l. The 4C 1 conformation of 13-D-glucopyranose.

Structure and shape of polysaccharide chains

Linkage of adjacent sugars in carbohydrate chains involves condensation between the hemiacetal OH group at C(1) on one residue and one of the alcohol OH groups of the next residue, with formal elimination of water (Fig. 2). Therefore, glycosidic linkage geometry can either be axial (a) or equatorial (13). Based on the assumption that the ring conformation is fixed, knowledge of the carbon to which the other glycosidic O is attached to def'mes the structure of a linear homopolymer with identical linkages. Thus, in contrast with proteins, different polysaccharides can share a similar primary structure. For instance, polymers of D-glucose, include cellulose [3- (1--->4) glycan, amylose a or-(1--->4), dextran or-D-(1--->6) and curdlan 13-(1--->3), and yet their chains arrange themselves into different higher order structures and indeed behave in markedly different ways. Polysaccharides thus, show low diversity in primary structure due to the few monosaccharide residues amenable for their biosynthesis. Also, polysaccharides tend to have regularly repeating sequences. Therefore, chemical diversity often arise from the degree and branching pattern and the geometry of the of glycosidic linkages. This fact restricts the number of unique analytical methods that can resolve effectively the type of polysaccharides present in food, which in fact means that often several methods must be used.

Page 120: Instrumental

103

o .o -J ~ o

o " " " ' ' I I C H 2 0 H

Figure 2. Conformation of two adjacent 13-D-glucose residues linked together by a glycosidic linkage in a cellulose chain. Rotation angles about the glycosidic bond are indicated.

Identity and purity

Identity defines the structural features which characterizes in chemical terms a population of molecular species which distinguish them among others of the similar or related type. In polysaccharides, chemical identity is dictated by the type and configuration of the sugar rings, the geometry and position of the glycosidic linkage, the sequence of monosaccharide residues also regarded as the fine structure, the chain length and the immunological response to specific antibodies

Purity in turn, in the context of the present review, is referred to as the extent to which polysaccharide species with a well established chemical identity are free of mixture with related and~or different compounds. In polysaccharide chemistry, impurities often arise from residual protein, lipids and mineral salts (chelated by uronic acid residues). Purity is closely associated to the extraction/isolation process by virtue of which a polysaccharide is produced, while identity is related to the botanical source where it was obtained from and to the possible chemical/enzymatic modifications carried out on the native materials. Both attributes are therefore assessed from a number of chemotaxonomic characteristics which allow to describe the sample features in very precise terms and to distinguish it unequivocally among other related compounds or sub-fractions. In the context of food additives legislation and certification, identity and purity are the prime concepts used to lay down specifications for food additives.

General criteria for polysaccharides purity include [5]: i) constancy in monosaccharide composition, ii) constancy in quantitative values of unique structural constituents, iii) constancy in the molar ratio of monosaccharide constituents,

Page 121: Instrumental

104

iv) uniform sedimentation rate on ultracentrifugation (through calibration membranes), and

v) uniform behavior on gel permeation chromatography or ion-exchange chromatography (i.e. a symmetrical elution peak is indicative of homogeneity).

Molecular Weight Distribution

While many proteins, which are synthesized under direct genetic control, are monodisperse, (i.e., all molecules, isotopic variations apart, are identical in structure and molecular weight), few polysaccharides (chiefly of microbial origin), if any, are synthesized in this manner and even for those which are chemically homogeneous, variation occur from molecule to molecule. If this variations are continuous in respect of all parameters, such as molecular size, proportions of sugar constituents and particular linkage types, separation into discrete molecular species is impossible and the material is said to be polydisperse. Hence, the molecular weight distribution descriptors are expressed in statistical terms: number average (&r weight average (-~4w), z average (Mz), and intrinsic viscosity (My) [6]. Polydisperse species have ratios M w / - ~ greater than 1, and in general,

~r,, < ~ < Mz+I<M v

Well-known experimental methods for determining molecular weight and molecular weight distribution include absolute methods: osmotic pressure, light scattering, ultracentrifuge sedimentation, diffusion; and relative methods: intrinsic viscosity, fractional precipitation, size exclusion permeation chromatography) high performance liquid chromatography (SE-HPLC) with refractive index (RI) detection, electrophoresis, thermal field flow fractionation (FFF). Use of relative methos to access molecular weight of polysaccharides, requires precise calibration with polysaccharides of known molecular weight (i.e. determined by an absolute technique), typically microbial pullulans or dextrans.

General separation and identification strategies

Before addressing specific tests for analysis of polysaccharide identity and purity, two broad strategies for identification of polysaccharide macromolecules are worth of mention. The f'trst one is to isolate first the unknown molecules from the substrate and cleave them subsequently, to further identify the resulting residues and fractions. The second strategy is to isolate and to characterize the molecules in their intact form in a single operation.

Page 122: Instrumental

105

Both gas chromatography (GC) and HPLC techniques are now commonly coupled to far UV, differential refractometry (RI), and mass spectrometry (MS) detection, and sensitivity has increased by orders of magnitude in recent years. Unfortunately, this approach demands laborious chemical work done on the material such as derivatisation reactions (e.g. periodate oxidation, methylation, hydrolysis, etc.) and also gives little information about the anomericity of the glycosidic linkages. Also, conventional (PAGE) and capillary electrophoresis (CE), using fluorophore labeling agents (e.g.8-aminonaphtalene-l,3,6-trisulphonate ANTS or 2-aminoacridone AMAC), i.e. flurophore-assisted carbohydrate electrphoresis (FACE), has started to be explored [7].

In the second approach, techniques often used as 'fingerprint' determinations predominate. These include spectroscopic methods such as Fourier transformed infrared (FTIR) and IH and 13C nuclear magnetic resonance (NMR) spectroscopy. The advent of high resolution proton IH-NMR (600 MHz) and cross polarisation magic angle spinning 13C-CP/MAS NMR in modem equipments have revolutionized the study of polysaccharide structure and conformation in the solid and in solution state [8]. In general, solid-state NMR studies are most informative in systems with relatively simple major molecular structure features such as polysaccharides [9]. Current NMR equipments provide a structural information with great detail, including anomeric configuration, and chain conformation. Also, available information directly available from NMR concerns the purity of the polysaccharide. For example, the detection of upfield 1H and 13C signals attributable to aromatic moieties may be indicative of residual protein, or it may show the presence of a contaminant introduced during a chromatographic step during isolation. If uronic acid containing polysaccharides chelate paramagnetic impurities during processing, severe line broadening of their 1H and 13C spectra is observed [10]. NMR is undoubtedly the most powerful instrumental method to achieve detailed knowledge about polysaccharides structure, however it has the disadvantage that the equipment is expensive and requires specialist technical support.

A third type of tests which are complementary to those described above, are based on specific proteins as biomolecular probes. One strategy uses lectins and monoclonal antibodies which are reactive with specific polysaccharide sites or terminus in the chain, and thus effectively, the corresponding Enzyme-linked Immunsorbent Assays (ELISA) can be developed specifically for the identification of a family of polysaccharides [11]. Yet another powerful biochemical approach, has been through the use of exo- and endoglycosidases. These enzymes are highly specific not only for a particular polysaccharide but also for the anomericity of the glycosidic bonds. They also show preferential cleavage for particular linkage positions.

Page 123: Instrumental

106

Degree of Polymerisation (DP) Determination

Both gel filtration methods [12,13] and methylation analysis [14], have been important methods for the structural analysis and determination of molecular weight and degradation products of polysaccharides. In the filtration methods the use of gels of various pore sizes have become available. The preparation is passed through a column of the gel and the eluant from the column are analyzed for carbohydrate. Calibration curves are generated from standard polysaccharides of known molecular weight size. The behavior of the polysaccharides on filtration on gels also yields information about the purity of a polysaccharide preparation as well as for assessing homogeneity.

Preferably using a strong base (e.g. methylsulfinyl methyl sodium), methylation analysis of polysaccharide involves complete methylation and hydrolysis to the constituent monosaccharides which are converted to partially methylated alditol acetates. It is essential that a complete methylation of all of the hydroxyl groups of a polysaccharide be achieved. Identification of the partially methylated alditol acetates and the types of the glycosidic linkages in the polysaccharides are based on the gas- liquid chromatography and mass spectrometry (GLC-MS)[ 15].

GLC has been used by Morrison [16], to determine the DP. The polymer was reduced, hydrolyzed and the released reducing sugars converted to oximes prior to acetylation. The degree of polymerisation is given by the ratio of aldonitrile to alditol. For linear polysaccharides the degree of polymerisation is calculated from the yield of the methylated derivative from the terminal residue. For branched molecules the average chain length of terminal chains can be determined.

If the molecular weight is adequately high, ultracentrifugation methods through membranes can be used [17,18]. The technique of sedimentation equilibrium in the analytical ultracentrifuge can provide absolute size and size distribution information in terms of molecular weight averages and molecular weight distributions. Problems commonly associated with light scattering techniques such as dust or aggregates do not interfer with centrifugation techniques. Density gradient analysis is important for assaying the purity of a polysaccharide preparation (i.e. freedom from unconjugated protein, lipid or nucleic acids) [ 19], and the sample can easily be recovered by further centifugation steps and by collecting the fractions.

The molecular weight of polysaccharides of low degree of polymerisation can be determined by methods based on the quantitative determination of a functional group of the polysaccharide and appropriate standard curves. Colorimetric procedures [20] can be measure the reducing groups of polysaccharides or can be reacted with radioactive reagents [21 ].

Page 124: Instrumental

107

Sedimentation velocity Sample homogeneity/purity

Shape information

Interaction information

Sedimentation equilibrium f Size (Molecular weight)

Size distribution

Density Gradient eqm. ~ Sample purity

Diffusion analysis Small mols. thro' polysaccharide matrix

Interface transport

Figm'e 3. Ultracentrifuge methods and the potential information available (from Harding [ 19], with permission)

Isatachophoresis

Isatachophoresis technique has been used for the separation of small ionic molecules, proteins and peptides [22]. The separation of ionic polymers proceeds according to their electrophoretic mobilities and the extent to which counterion binding reduces their net effective change. The method has been used for the determination of the chemical heterogeneity of carboxymethyl cellulose (CMS). CMS samples with various degree of substitution (DS), show different isatachopherograms. Higher DS values give sharper zone boundaries, indicative of a high degree of homogeneity, in comparison to lower DS values with broader substitution range [23]. However, samples with the same DS value indicated differences in carboxylmethyl distribution in all cases in addition to the major component.

Page 125: Instrumental

108

Acetolysis

Acetolysis of polysaccharides results in the complete acetylation of the flee hydroxyl groups of the polysaccharide and the selective cleavage of glycosidic bonds [2, 24]. The ( 1 ~ 6) glycosidic linkage is highly susceptible to acetolysis whereas the (1-->2) and the (1---> 3) linkages are comparatively resistant.

It is a useful method for investigating the structure of polysaccharides from micro- organisms. Yeast mannans structure has been studied from the nature of hydrolysis products, identified by gel permeation chromatography methods [25].

Purity Determination by Phase Solubility Analysis

Conclusions can be drawn on the purity and identity of a substance by means of phase solubility analysis (PSA) without a priori knowledge of the chemical structure of the sample. The technique is derived from Gibbs phase rule and involves the analysis of the composition in solution as a function of the total amount of solid added and yields a phase diagram [26]. When phase equilibration and solubility analysis are used to prepare a pure solid, separated from its impurities, the process is often called "swish purification". This technique can also be used to enrich impurities in solution phase, for their further identification [27].

Analysis of mixtures of mono- and oligosaccharides

For many analytical purposes a value for total free sugars, expressed possibly in terms of a monosaccharide, may be sufficient, in other cases a detailed analysis of the various carbohydrate species may be required. The analysis of sugars found in foods or as components of polysaccharides, depended on the use of both physical and chemical properties. The measurement of the free sugar in most foodstuffs therefore involve the analysis of mixtures. The analysis depends primarily on whether the sugars are in solution or whether they need to be extracted from the foodstuff. Extraction methods of polysaccharides usually involve the combined use of various types of alcohols [28].

The detection of total sugar content relies on the use of specific assay methods (e.g. anthrone and phenol methods). Reagents such as concentrated acid to hydrolyze the oligosaccharides glycosidic linkages to monosaccharides and to produce a suitable chromogen (e.g. hexoses produce 5-hydrohymethyl fiirfiaraldehyde) [29] are often used. A number of other assays have been reported and the development of suitable automated assay systems monitoring of chromatographic columns is a major advantage.

D-Glucose, fructose, sucrose, lactose and maltose, which occur in the diet, can often be analyzed quite well by reducing sugar methods. However such analysis is

Page 126: Instrumental

109

difficult and a combination of enzymatic and acid hydrolysis needs to be used. The most useful approach is either chromatographic separation and analysis, or the specific enzymatic methods. Quantitatively, gas chromatography is the most suitable method [28], using a wide range of column conditions. Two classes of derivatives seem to provide the most satisfactory separation of sugar mixtures: the trimethylsilyl (TMS) derivatives of the sugars themselves and the alditol acetates [30] prepared after reducing the sugars to alditols with sodium borohydride.

ELISA Techniques

Immunological methods are becoming increasingly more specific and powerful for the structural characterization of macromolecules. Polysaccharides elicit an immune response by virtue of which antibodies which recognise specific carbohydrate residues can be raised (e.g. in rabitt's blood serum) and subsequently purified. More recently, methods using enzymes to detect and amplify the antigen-antibody response have been developed. ELISA techniques have developed for the structural characterization and analysis of carrageenans [31] and other polysaccharides [32], as discussed below.

'In situ' identification/characterization and quantification

Combination of techniques including fluorescence, bright-field and near infrared (NIR) microscopy, microscope photometry (MP) and digital image analysis (DIA), allow in situ identification and/or characterization and quantification of carbohydrates in cells, tissues and food products [33, 34]. With the development of epi-illuminating systems for fluorescence microscopes, and the increased availability of improved bright-field and fluorescent probes for specific groups and reactions [35], it is now possible to carry out relatively specific chemical determinations on microscopic structures and analysis of carbohydrates. Bright-field microscopy is very useful technique for visualizing carbohydrate structure and composition, while NIR and microspectrophotometry offers the ability for mapping distributions of carbohydrates in raw and processed food materials [33]. Many microscopic methods can be used in combination with digital image analysis (DIA) to determine the sizes and shapes of polymeric systems in foods (properties of starches, cell walls etc.) [36, 37].

Page 127: Instrumental

110

EXAMPLES

STARCH

Starch, the major reserve storage polysaccharide of most plants, occurs as water- insoluble granules, the size and shape of which vary with species and maturity of the plant. Under molecular scales, the starch granule is a giant highly organized structure. A typical 15kmi corn starch granule is composed of over a billion molecules, which is composed essentially of polymers of u-D-glucose with trace amounts of protein and lipid componems. The majority of starch granules contain two polysaccharide fractions: amylose and amylopectin. Amylose is a linear chain consisting of up to 4000 glucosyl residues connected by cz-(1-~4) glycosidic linkages. Amylopectin is a branched polymer of repeating glucose units connected by tx-(1-~4) linkages and branched with ct-(1-->6) linkages. The ratio of amylose to amylopectin varies in plants from regular (1:3), high amylose (1:1) to waxy (up to 100% amylopectin) [38]. The characteristic blue color with iodine in potassium iodide is caused by complexing of amylose with iodine. The amylopectin molecule does not appear to form stable complexes with iodine but gives a very pale red color in its presence. Amylose and amylopectin in the starch granule are packed together in a way that is not yet fully understood.

Starch is a particularly attractive hydrocolloid for textural modification because it is both natural and safe. There are many types of starch, derived from corn, waxy maize, wheat, potato, rice, tapioca, pea, among other. Different starches have different properties and are applied in the food industry as thickening and gelling agents. Native starch, although widely used in the food industry, has limited resistance to the physical conditions applied in modem food processing. In order to improve this resistance, native starches are chemically modified. These modifications can either be chemical or physical. Chemical modifications include acid hydrolysis, oxidation, esterification or etherification and cross-linking [39]. Partial hydrolysis of starch is employed to prepare maltodextrins, which are polymers of amylose and amylopectin of shorter chain length than that in the native starch.

Physical modification of native starches is mainly achieved either by drum drying or extrusion of a native or chemically-modified starch slma3,, whereby starch is obtained in a so-called pregelatimsed state [40]. Starch molecules differ from those of other polysaccharide hydrocolloids in that they are made functionally useful only by disrupting the granule structure, i.e. by gelatinisation [41]. During heating in the presence of water at a characteristic temperature, known as the gelatinasation temperature, the granule irreversibly swells to many times its original size, crystalline order is lost and amylose is preferentially solubilised. On cooling to room temperature, the solubilised or partially solubilised amylose aggregates and some crystalline order is recovered, and as a consequence a gel is formed. These molecular processes are collectively known as retrogradation and have important dietary and textural

Page 128: Instrumental

111

implications. The overall benefit of subjecting starch to a gelatinasation/retrogradation cycle is to obtain a starch with the ability to form a paste in cold water. The term resistant starch (RS), has been coined to gelatinizect/retrograded and physically unavailable starch, which is indigestible by amylase m vitro and m vivo [42]. Novel concentrated sources of RS with a claimed 30% fraction which analyses as dietary fiber have recently been launched commercially in the US and Europe under trade names such as Novelose | and CrystaLean ~.

This large number of different commercially available starches, illustrates the importance of the correct choice of analytical strategies in order to access the key molecular features underpinning their identity and performance.

Ewers method for starch purity analysis

The Ewers method [43] used to determine the starch content, based on the partial acid hydrolysis of starch followed by measurement of the optical rotation of the resulting solution. This based on the controlled acid degradation of the starch, in which firstly the granules are fully gelatinized and subsequently the solubilised starch is hydrolyzed. Hydrolysis is stopped by fast cooling. A different specific optical rotation can be applied for different starch sources. True starch content was calculated by determining the non-starch components, and the residue was assumed to be starch. Clarification and removal of protein is commonly done by addition of Carrez reagent.

Although this method dates back from 1908, with few modifications, it is still used and in fact is the official European Commission method for determination of starch purity (regulation 2169/86). Alternatively, an approach to disperse the starch in hot calcium chloride solution to clarify and to calculate starch content from the measurement of optical rotation [44] it is used.

Dextrose Equivalent (DE) Determination

Maltodextrins (and indeed, glucose syrups) are produced by acid/enzymatic partial hydrolysis treatments of native starch, resulting in products with improved functional properties. Their molecular weights (and physico-chemical properties) are related to the degree of hydrolysis which is characterized by one parameter, the 'dextrose equivalent' (i.e. D-glucose) or DE value, and is a measure of the total reducing power of all sugars present towards Fehlings solution. Thus a degradation product with a high dextrose equivalent has been subjected to a greater degree of hydrolysis than one of a lower dextrose equivalent. Degrees of esterification (DE) in typical commercial maltodextrins vary from 2-19. Glucose syrups usually contain glucose, maltose and higher maltose oligosaccharides, maltotriose and maltotetrose mixtures.

Page 129: Instrumental

112

Any method for reducing sugar determination can be used, but traditionally the Lane and Eynon method [45] is used to determine the content of reducing sugars in a sample and still is the method of choice for some industrial applications. Alkaline cupric salts giving cuprous oxide after the reaction of reducing sugars. Their concentration is monitored titrimetrically, compared with a reference included in standard tables and calculated as a percentage of the dry substance [28]. Careful control of the heating is required and for most accurate analysis two titration readings are necessary; the first to establish the approximate volume of the test solution to effect reduction, and the second to measure the precise volume required. Corrections to the standard table values have been also reported improving the original method [46].

A number of specific assay methods have been developed for the quantification of individual oligosaccharides, among colorimetric methods, which are used for the gross determination of total carbohydrate content or total reducing sugar content [29]. Such assays use alkaline 3,5-dinitrosalicylic acid [47], alkaline ferricyanide [48] or alkaline picric acid [49]. However the use of oligosaccharide fractionation by gel permeation chromatography is now recommended as the best method for characterization of starch hydrolysates and the determination of dextrose equivalent is based on the actual composition of oligosaccharides [50]. Fractionation of starch and its hydrolysis products using Bio-Gel P-2 [51], microspherical cellulose [52] and porous glass beads (CPG-10) [53] have also been reported.

Infrared and NMR spectroscopy of starch

The infrared spectroscopy of potato starch is different from that of cornstarch, particularly in absorption regions for oxygen-containing groups. Thus in cornstarch, absorption is stronger at 1681, 1053-952 and 855 cm ~, whereas in potato starch the band at 926 cm 1 is stronger [54]. Modified starches show bands which are characteristic for the different derivatives, and thus effectively the degree of modification can be determined quantitatively [55].

Water absorption properties of wheat flour depend on the degree of mechanical damage of the starch after the milling of hard wheat. These properties are critical in flour quality, as far as performance on automatic dough handling equipment during the bread baking process is concerned. Near infrared (NIR) reflectance measurements have been used successfully to determine the degree of starch damage of commercially milled flours [56, 57]. The basis for this determination is consistent with the hypothesis that the mechanical damage is associated with cleavage of hydrogen bonds between starch molecules and water molecules. Furthermore, observations that NIR reflectance measurement correlated with both digestibility and extractability characteristics of damaged starch which, form the basis of chemical methods for its determination, strengthen confidence in the NIR determination [58].

Page 130: Instrumental

113

Investigative high resolution NMR techniques have also been applied to delucidate in detail the structure of starch components. Using anomeric proton signals it is possible to quantify ratios of both branch points and reducing tenninii to main chain residues. This, the degree of branching of amylopectin (and potentially amylose), and the DE value together with the degree of branching for starch degradation products can readily be obtained using this technique. As some starches (notably potato) contain covalently-bound phosphate groups, they are amenable to 31p NMR analysis. First results [59] indicate that, for a number of potato varieties, C-3 phosphorilation is nearly constant, but C-6 shows significant differences.

Bright-field microscopy technique as well is useful for visualizing starch granules in wheat flour which have been damaged by milling, and allows routine measurements of the degree of starch damage in diverse flours using image analysis. A relatively unknown dye, Hessian Bordeaux is used, replacing the more traditional stain, Congo Red [34, 60].

Starch crystallinity

In the native form, the starch granule exhibits considerable cristallinity (about 40% by X-ray diffraction), which in turn distinguishes the following polymorphic forms: A (in cereals), B (in tubers) [61]. An intermediate C type, is less frequently observed. The different forms are readily and unambiguously identifiable by wide angle x-ray diffraction (WAXS) (Fig. 4) [62], or by 13C CP MAS NMR [63]. In both polymorphs the polysaccharide chains are thought to associate in six-fold left-handed double helix conformations with a pitch of 2.138 nm, but to differ in their unit cell dimensions (i.e. the lattice) and in water association [64, 65, 66].

The most notable difference between the 13C CP MAS NMR spectra of the A and B forms is the occurrence of the C-1 peak as a triplet (-~ 102.5, 101.5, and 100.6 ppm) in the A form but as a doublet (-~ 101.5 and 100.5 ppm) in the B form [67, 68]. Both forms comain a distinct C-6 peak at -~ 62.7 ppm. Another form, the V form, can be obtained by precipitation of amylose with a variety of organic solvems and compounds. Solid state NMR spectra of V forms have been reported [60, 63, 69, 70].

Amyiose and Amylopectin Fractionation

Due to their different extent of branching and effective molecular mass, amylose and amylopectin behave in markedly different ways, particularly in the manner in which they gel upon cooling from a gelatinized starch solution [71]. The different solubility of amylose and amylopectin in aqueous alcohols (thymol or n-butanol), is exploited in order to achieve the fractionation of isolated starch [72]. Other techniques used to fractionate both polymers include gel permeation chromatography (GPC) and recently by thermal field fractionation (FFF) (Fig.5)[73].

Page 131: Instrumental

114

Although amylose and amylopectin do not differ each other in terms of their residue unit, u-D-glucose. Chemically amylopectin offers substantially greater structural diversity than does amylopectin, due to the extensive branching in the former. Selective cleavage of amylopectin chain, using highly purified enzymes, namely pullulanases, has been used in order to elucidate the free structure of amylopectin from different botanical sources of starch [74]. Based on this approach, an important technique which is now widely used, involves the complete debranching of amylopectin followed by fractionation of the linear chains by gel filtration. The resulting elution pattern reveals the size distribution of the constituent chains, i.e. the chain profile. The technique originally introduced by Lee et al. [75], it has now been ref'med by Hizukuri [76,77]. Use of GP- HPLC with monitoring by low angle laser- light scattering photometer (LALLS) and a differential refractometer (RI), it has been shown that amylopectin structure is related to botanical source of the starch. The multimodal distribution of the peaks obtained has led to the proposal of the 'cluster' model [76].

GUM ARABIC

Gum arabic is a highly branched acidic heteropolysaccharide produced as an exudate from various species of the genus Acacia. The main source of gum arabic of commerce is Acacia senegal L. Willdenow, which undoubtedly is the most available gum in the commercial producer countries of Africa, namely Sudan, Nigeria, Chad, Ethiopia, Senegal, with lesser amounts available from Ghana and Zimbabwe. Gum arabic has long been used in a variety of foods and beverages, especially as a natural emulsifier and encapsulating agent of citrus flavors and also in confectionery applications where it inhibits sugar crystallization and confers a glossy appealing appearance.

Since 1991, cold weather, foliage attack by locusts and changes in export duties on gum arabic have severely reduced exudation and gum supplies coming to market. This has led to the search for 'substitutes' of gum arabic, particularly in modified maltodextrins and 13-cyclodextrins [78,79]. However, the unique combined functionality of gum arabic as a natural emulsifier, good mouthfeel characteristics and low solution viscosity cannot be matched by any other gum and satisfactory alternative materials have not been developed. An obvious searching route would be to seek for alternative botanical sources for exudate gums of similar type, and indeed gum arabic under trade is known in practice to be a mixture of several A cacia related species. This has resulted in increasing concern about the precise definition of gum arabic, chiefly among regulation official bodies, gum producing companies and end-users in the food industry. The precise chemical identity of gum arabic poses a very difficult problem

Page 132: Instrumental

115

. . . . . . . . . . . i

PO,O,o s,orch I

R,O r ,,.,, I-.i

ATopioco Storch

6" 10" 14" 18' 22' 26" 30" 3/." 2 0 - - - - ~

Figure 4. Wide-angle X-ray diffraction for two starches (potato and tapioca) in powdered granular form. The amylopectin fraction crystallize as distinguishable A and B polymorphs (from Clark and Ross-Murphy [62], with permission).

Z �9

t*

i r a - - |

0

without salt with salt

L amylopectin

1 . . . . i l ~ I 1 ] l

20 40 60 80 100 120 140 TIME (rain)

Figure 5. Thermal field flow fractionation fractogram of a cationic starch in DMSO with added salt (right peaks; 1.0 • 10 "~ M LiNO3) and without salt (left peaks). From Lou et al. [73], with permission.

Page 133: Instrumental

116

for the food and beverages industry, mainly because the detection of adulterating non- ~ermitted gmns has proved extremely difficult. Indeed, even by the use of expensive 3C solid state NMR spectroscopic methods, large variations even between

authenticated gum arabic samples can still be found due to the expected natural variability [80].

The Joint Expert Committee for Food Additives (JECFA) of FAO defmed 'gum arabic of commerce' as the dried exudation of Acacia senegal (L. Willdenow) or related species of Acacia Fam. Leguminosae [81], while in the US the Food and Drug Administration defmes it as the exudate gum from various species of the genus Acacia family Leguminosae [82]. Both defmitions did not include any specifications about the chemical identity of gum arabic. Recently, JECFA proposed new specifications [83], and introduced three significant additional criteria: i) gum arabic should include gum from Acacia senegal and only "closely" related species (which according to the early Bentham's classification includes two sub-genera, namely sub-genus Acacia (= series Gummiferae Benth. e.g. A senegal) and sub-genus A culeiferum (= series Vulgares. Benth. e.g.A, seyaI)) ; ii) optical rotation limits (-26 to -34 ~ should be adopted; iii) nitrogen content should be set between 0.27 and 0.39%.

These criteria, along with the battery of physico-chemical analytical tests typically conducted on exudate gums, namely intrinsic viscosity, equivalent weight, individual sugar residues and amino acid composition, have been indicated as to be inadequate to unambiguously differentiate between closely related species of Acacia senegal and to render inadmissible gums which fulfill the description [84], unless the sets of analytical data are considered globally using multivariate statistical procedures as it is described below.

Three different methodological strategies have been pursued in recent years, in order to address the problem of gum arabic identity, namely �9 chemometric methods, �9 structural characterization studies, and �9 immunological techniques The potential of each of these is discussed in fin~er detail next.

Chemometric methods

Chemometric methods make use of multivariate statistics, namely principal component analysis (PCA), discfiminant component analysis (DCA) and cluster analysis (CA) in order to evaluate similarities between patterns of a series of analytical attributes in a set of samples. These statistical techniques are widely used for both research and quality control purposes in order to establish a classification of items using a projection of multivariate data sets [85-87]. The implementation of chemometric methods to classify exudate gums from Leguminous botanical sources based on a large number of analytical data was first done by Jurasek and co-workers

Page 134: Instrumental

117

[88-91]. Fig.6 is a DCA loading-loading plot showing how gum samples from the Combretum species can be identified and discriminated from Acacia gums based on nine carbohydrate parameters. Gum exudates from the genus Prosopis represent another group of exudate gums which have evoked commercial and agricultural interest [92]. Prosopis gums have also been successfully identified and distinguished from Acacia gums by this technique [91]. In a recent paper [93 ], the classification procedure has been refined using a PCA method called multiple nearest neighbor (MNN), based exclusively on the amino acid composition of a set of commercial Afifcan Acacia gums. This has allowed to compute an empirical index ('Senegal Number') of closeness of the species to Acacia senegal. This approach appears to be a promising option, which may lead to include an operational parameter in the official def'mition of gum arabic in the future based on a chemometric classification.

Structural analysis

Structural studies aimed to characterize the detailed chemical and steric features of gum arabic molecule have included analysis of the composition of the constituent sugar residues by 13C NMR [94,95]; profiling of the aminoacids of the proteic minor component by chromatographic techniques [78, 80, 96, 97]; composition and size of the individual molecular fractions by gel permeation chromatography (GPC) [98-100]; high performance size exclusion chromatography (HPSEC) [101] coupled to UV, RI and light scattering (both in static and dynamic mode). GPC procedures have also been allied with immunological techniques (ELISA and immunoblotting) for the specific identification of gum arabic fractions by purified antibodies [ 100, 102, 103].

It is well established that in addition to the carbohydrate components, gum arabic contains -~ 2.2 % protein [97]. As well as having a crucial role in emulsification [104], it is now evidem that the protein component is central to the overall primary structure. GPC chromatograms of gum arabic show it to be an heteropolymolecular material, formed by three distinctive components (Fig. 7).

The main fraction (Fraction AG Fig. 7B), whose contribution to the total is --88%, has a lower protein content than unfractionated gum (<0.4%) and an average molecular mass of-~2.8 • 105 , which does not change significantly on extensive proteolysis. A second fraction (Fraction AGP, Fig 8C), represents -~10.4% of the total, has a much higher protein content (~12%) and an average molecular mass about 5 times that of the major fraction (14.5 • 10s). On proteolysis, the molecular mass of fraction 2 drops to that of fraction 1 [98,99,105] suggesting a 'wattle blossom' structure, with on average, five branched carbohydrate assemblies similar, or identical, to those in fraction 1, linked together by a polypeptide chain. A third, minor (-~1.24 %) glycoproteic fraction (GP, Fig 8D) contains 47% protein which is 25% of the total protein and a molecular mass of 2.5 • 105.

Page 135: Instrumental

118

CXl o a

[] [] % 13

/ [] [] []

D D ~ D

[]

%

D C l

Figure 6. DCA utilising two categories of objects (Acacia gums, 33 samples and Cobetrmn gums, 30 samples). Features are nine mainly carbohydrate parameters. Axes: first and second discriminant components with corresponding t-values 19.7 and 5., [], Acacia; A, Combretum; A, comercial Combretum nigricans and commercial Combretum samples. From Jurasek and Phillips [91], with permission.

GUM ARABIC �9

A

c

I- V0 V,,

DECREASING MOLECULAR MASS

Figure 7. Gel permeation chromatograms of gum arabic and its fractions" (A) whole gum arabic; (B) fraction 1; (C) fraction 2; (D) fraction 3A. From Randall et al. [99], with permission.

Page 136: Instrumental

119

I I

3

. . . . - - -

I I I

I I

5 6

Vt Vo Vt J

Figure 8. GPC elution profiles of 1% w/v gum solutions: (a) samples 1-5 as monitored by RI; (b) samples 6-8 as monitored by RI; (c) samples 1-5 as monitored by UV at 206 nm; (d) samples 6-8 as monitored by UV at 206 nm. From Osman et al. [ 103], with permission.

Page 137: Instrumental

120

GP chromatograms (Fig. 8) of gum arabic, show the elution profiles of the various samples of gum arabic. Figs. 8a and 8b show the molar mass distributions of gum arabic as identified by refractive index (RI) and in Figs. 8c and 8d by UV detection [103]. The reason the two elution profiles are different using the two detection techniques is that RI is essentially sensitive to the total concentration of material present, whereas UV is more sensitive to the chemical nature of the various molecular mass fractions. At 206 nm, UV spectroscopy detects the carboxyl groups associated with the polysaccharide and also the amino acids which make up the proteinaceous component; previous NMR and methylation analysis [106], suggests that all three fractions have similar branched structures based on a 13-(1---~3)-linked galactan core. The presence of these three components (particularly of the AGP fraction), whose exact proportion is characteristic of the sample, is suggested to be a more accurate diagnostic chemical technique for identifying commercial gum arabic than the aggregate properties optical rotation and %N, currently considered in JECFA's def'mition [84].

ELISA techniques

The fact the gum arabic and other chemically related gums can elicit immune response is well recognized [ 107,108]. However, the first detailed study of gum arabic using immunoassay technology was described recently [ 109]. Following their method an enzyme linked immunosorbent assay (ELISA) has been developed for the specific identification of Acacia senegal gum [ 102,103]. The technique is based on the use of antibodies that have been raised in rabbits which recognize and interact with a specific binding site in the gum molecule, i.e. epitopes. The precise nature and size of the epitopes to many of these antibodies is unknown, with contradictory views. Some of these point to specific carbohydrate terminii at the epitopes, surface of low and high molecular weight components [5, 109,110,111], and some others to the amino acids present in the fractions AG and AGP, since very little, if any, aff'mity was found for the AG fraction [112]. Regardless of the precise location of the immuno-active site, the ELISA test can reliably detect concentrations as low as 10 ~tg ml ~ of gum arabic with a good reproducibility within the range 10-100 ~tg ml ~. The ELISA approach has been used to differentiate gmn arabic samples from A. senegal from other exudate gums (ghatti, tragacanth, karaya) currently used as food additives. However, some cross reaction occurs between gum arabic samples from the same genus series. The method undoubtedly, offers great potential to develop a quick an easy test to identify the presence of gum arabic in foodstuffs as well as the common adulterants.

Page 138: Instrumental

121

ALGINATES

Algae, just as terrestrial plants do, rely on cell wall matrix polysaccharides in order to build up their physical structure. Unlike terrestrial plants though, algae somehow need greater flexibility in order to withstand the wave and tidal forces that they are permanently subjected to. Nature achieves this, by the biosynthesis of a 'soft' polysaccharide matrix around rigid cellulose fibers. This matrix is composed largely by polysaccharides, collectively known as phycocolloids, whose prime property is to be able to form gel networks. Man has learned to exploit the gelling capacity of phycocolloids in order to modify the mechanical properties of foods. As for other food hydrocoUoids, the extraction and purification of seaweed polysaccharides constitutes today a large industrial activity. In this and the following section, the analysis of two different kinds of phycocolloid families with a large bearing in food industry are discussed, namely alginates and carrageenans.

Alginate is among the major industrial polysaccharides. The world's demand of alginate is of about 23,000 ton per year, all of which is currently obtained from brown seaweeds (Phaeophyceae) of the species Laminaria hiperborea, Macrocystis pyrifera and Ascophuyllum nodosum. Alginate is available commercially principally as the sodium salt form, although alginic acid, other metal salts (potassium, calcium, ammonium) and derivatives (propylene glycol alginate) can be obtained. Sodium alginate is soluble in water, producing viscous solutions. The especial properties of alginate, however, are based on its ability to form gels in the presence of certain cations, notably calcium ions, a property that has successfully been utilized in a variety of food applications.

C O O H 0

== ..- 1 . 0 3 n m . - = '

, 1

".. ~ ~ C O O H O H ~ ! Uo ' --o---

i o o i o i |

' ~ - - - - - - - - 0 . 8 7 n m - - - - - - - - - - ~ '

(a) (b)

Figure 9. The constituent carbohydrate residues in alginate are: (a) [3-D mannuronic and (b) ct-L-guluronic acid residues

Page 139: Instrumental

122

Alginate is a (1--+4)-linked linear co-polymer of 13-D-mannuronic (M) and its C5 epimer ct-L-guluronic acids (G; Fig. 9). The monomer residues are arranged in homopolymeric blockwise patterns of three different types (Fig. 10): poly-L- mannuronate (M blocks), poly-L-guluronate (G blocks) and in heteropolymeric sequences which approximate to a disaccharide repeating structure (MG blocks).

Enzymatic studies [113], however, have shown departures from this idealized, regular, alternating sequence. The relative content of M, G and MG blocks as well as the alginate molecular weight distribution depend on the alginate source, namely the type of seaweed as well as the precise tissue in the algae (e.g. fronds, stipe or fruiting bodies) where the alginate has been harvested from.

M-G-M-M-M-M-M-M-M-M-G-M-G-. ...... M-block

G-M-G-G-G-G-G-G-G-G-G-M-G-M-. ...... G-block

M-G-M-M-M-G-M-G-M-G-M-G-G-M-M-. ...... MG-block

Figure 10. alginate

Schematic illustration of the main monosaccharide block structures of

Due to the different glycosidic linkage geometry between adjacent sugar residues on each block, the chains are arranged as flat ribbons in poly-L-mannuronate, and as buckled ribbons in poly-L-guluronate. The technologically and biologically important physical properties of alginates in solution, gels and algal tissue are largely determined by the relative amounts of the three types of block present, and hence by the molar ratio of M:G. There is strong evidence that formation of calcium alginate gels occurs predominantly by association of poly-L-gu|uronate sequences [114-116]. This has been rationalized as a result of specific chelation of calcium ions (or other ion of similar size) in the cavities formed between adjacent residues in poly-L-guluronate sequences as in the so-called 'egg box' model [ 117].

Page 140: Instrumental

123

Analysis of chemical identity and fine structure

Since the functional properties (i.e. the rheological behavior), of alginates are dependent upon the chemical composition, it is clearly desirable to be able to analyze the M:G ratio and ideally the block structure of the polymer. These three parameters too are the major pieces of information so as to establish the chemical identity of an alginate sample. Although the monomer composition (M:G ratio) is in itself a useful parameter, the properties of a sample of alginate can be predicted more accurately from knowledge of the block structure.

One approach is to isolate the three types of block structure by partial acid hydrolysis and fractional acid precipitation and quantify each by the a chemical assay method such as phenol sulfuric test [118]. The blocks, however should not be considered as ideal, since typically the poly-L-guluronate sequences will contain about 10-15% mannuronate, so an allowance for it must be made for accordingly. There are two well established instrmnental methods to determine the block composition of alginate, namely by circular dicroism (CD) and by nuclear magnetic resonance (NMR). Although molecular probes (polyclonal and monoclonal antibodies) to locate alginate in living tissues, have been raised in rabbit serum, the technique needs fin-ther refinement, especially to identify the structures to which the antibodies bind [ 119].

Circular dicroism (CD), is the difference in absorption of left and right circularly polarized light by a dissymmetric molecule, and is typically only about 10 -2- 10 4 of the total absorption of light by the material (for a comprehensive review on principles and applications of CD to carbohydrate structure analysis, see for example Morris and Frangou [ 120]). CD bands may be either positive or negative depending on whether left or right circulary polarized light is absorbed preferentially. Electron transitions (with a small electric dipole moment but a large magnetic dipole give strong CD bands, n---~* transitions of carboxylic acids, salts, esters, and amides, in which a non- bonding electron of oxygen or nitrogen is prompted to an antibonding orbital, falls into this category. The CD may be def'med quantitatively as the angle of ellipticity (0), whose tangent is equal to the ratio of the minor to the major axes of the ellipse traced by the net electric vector as a result of the differential retardation of the right and left components of the polarized light beam, as it passes through an optically active substance. The major axis being proportional to the sum of the residual intensities of the left and right circularly polarized components (IL + IR), and the minor axis to the difference between them (IL - IR), Thus

tan (0)= (IL- IR)/(IL + IR) (2)

CD is commonly expressed as a molar quantity, according to

[0] = 0M/cl (3)

Page 141: Instrumental

124

where M is molecular weight, c is the concentration (g/ml) and 1 is the path length (mm).

The presence of carboxylic substituents in poly-L-mannuronate and poly-L- guluronate structures of alginates makes them especially amenable to this technique. Indeed, CD allows to determine the block structure of less than 1 mg of sodium alginate [116]. Alginates exhibit CD behavior in the UV region 190-245 nm, the spectra of D mannuronate and L-guluronate being very different. The CD spectra is also modified by the presence of adjacent residues in the polymer chain, so it is sensitive to block structure as well as to overall composition. It follows from Figure 11 that the CD spectra of alginate show a peak at 200 nm and a through at 215 nm., whose height and depth are dependent upon monomer composition. Equations are given to compute the monomer M/G ratio [116], without measurement of concentration. Most commercial alginates show CD spectra entirely in the negative region of molar ellipticity [0], and the estimate of the ratio of mannuronate to guluronate residues can be obtained by simply doubling the measured peak/through rat io (0through " 0peak / 0through)- In order to f'md the block structure it is necessary to consider the whole shape of the spectrum and use an iterative, least square minimization computer routine. Unlike NMR, CD van be used without any degradation of the samples. The solution must be adjusted to a pH of 7.0 + 0.3 and divalent cations must be absent. Solutions of < 1 mg ml ~ are used and for block structure analysis (but not for M/G ratio) the polymer concentration must be accurately known. This method has been used by Craigie et al. [121], to examine tissues from a number of algae.

~H-NMR for the analysis of block structure in alginate has been developed into a routine technique, the possibility to work at high temperatures and solvent suppression techniques, allow at present minimally depolymerized samples (DP 20-30) using mild hydrolysis with acid (30 min, 100 C, pH 3.0) in order to reduce the viscosity of their solutions, Grasdalen et al. [122], were able to assign peaks in the proton NMR spectrum which differentiated G residues with neighboring G from those with M residues as neighbors. Data from I H NMR and from chemical analysis correlate well although there are some discrepancies in samples with a high proportion of mixed doublets [122]. Further work using 400 MHz ~H NMR [123], gave information on the proportions of the G-centered triplets (GGG, MGG, GGM and MGM).

Page 142: Instrumental

125

1001

0

[01

-1000

-2000

-3000

-aO00

I I

I i I

l / l t l / ' I ' I 'k fnm)

I 2o0 . ~2~0 220 230 2~0

I I

\ 4 ' /

/--\ ~ / I , " I" "\', 1"I'/ i ' V , , ; / i /

/ / I I I / �9 /

! i / i / ,! /

I /"\ \ l II # I

~, (nml 200 210 220 230 2/.,0

[o ' ] 0

Ii / ', / I/ I ', / \ /

- 2 0

- 3 0

0[ Figure 11. Left: CD of alginate blocks approximating in structure to poly-L-guluronate ( - - ) , poly-D-mannuronate (- - -), and mixed ( - - - ) chain sequences. Right: Comparison of the CD behavior of alginate mixed-sequences ( - - ), and spectrum (- - -) synthesized by linear combination of 50% of the spectra for each type of homopolymeric block. Reprinted from Morris and co-workers [ 116], with permission.

Natural abundance ~3C NMR has also been used in order to increase the resolving power of the technique. However, it is not suited for routine analysis because of the extended accumulation time that is required to record good resolution spectra. On balance, IH NMR is probably the most suitable technique for routine analysis of alginate structure and a 100 MHz Fourier transform machine is perfectly adequate, although clearly more information can be obtained from higher power machines. The composition of alginate extracts from different algae species is shown in Table 1.

Page 143: Instrumental

126

Table 1 Fractional Composition of Alginates as Determined by ~H-NMR a

Botanical origin

Laminaria di gitata Laminaria hyperborea Macrocystis pyrifera Ascophyllum nodosum

Fractional Composition b

FG FM FC, G FMM FMG FGM Fc, c~ FMMM

0.42 0.68 0.27 0.43 0.15 0.15 0.70 0.30 0.60 0.20 0.10 0.10 0.39 0.61 0.21 0.43 0.18 0.18 0.43 0.57 0.18 0.32 0.25 0.25

0.22 0.10 0.52 0.06 0.20 0.20 0.13 0.17

a From Grasdalen [ 123], with permission. b The following relationships between monad, diads and triad frequencies hold:

Fc~ + F~ea + FGM + FM~ = 1 F~ + FMG = FG + Fr~ + FMG + FM F~ = Fc, c~ + FM~ + F~M + FMGM FMG = FGM = FC,-GM + FMGM FMGG = FGGM

CARRAGEENAN

The red seaweeds (Rhodophyceae) produce a family of phycocolloid polysaccharides, collectively known as galactans, since all of them have a galactose backbone joined together by glycosidic linkages of alternating type. Members of this family of polysaccharides include agar, furcellaran and carrageenans. Carrageenans bear special importance in food systems and have been used to thicken foods for centuries, the earliest records of use being in Ireland, where the red seaweed Chondrus crispus ('Irish Moss') was boiled with milk to give a thickened product. In the meantime, these seaweeds were also collected along the French coast of Brittany, where the bleached "lichen" (a blend of Chondrus crispus and Gigartina stellata) was used to prepare a milk-gel known as blanc-mange. Today, more than three-quarters of the carrageenan production goes into food industry. A broad range of rheological properties can be generated and f'mely modulated in foods by making use of the thickening and gelling properties of the various types of carrageenans [124]. These superior properties are a direct consequence of their ability to form gels at extremely low concentrations and to increase the viscosity in food systems, along with their capacity to interact synergistically with other polysaccharides (konjac flour, locust bean gum, starch, etc.). Also, carrageenan exhibits a strong reactivity for casein, a property which is exploited in many dairy applications (e.g. stabilization of cocoa powder particles in chocolate drinks imparting a pleasant mouthfeel). Carrageenan- yielding seaweed species (carrageenophytes) have been reported as occurring in seven

Page 144: Instrumental

127

different families of seaweeds, namely: Solieriaceae, Gigartinaceae, Furcellariaceae, Phyllophoraceae, Hypneaceae, Rhabdoniaceae, and most recently, Rhodophyllidaceae [ 125]. Depending on the region of the world, some species of these families are cast on beaches, while others are maricultured (e.g. Phillipines).

Residue composition

Carrageenans are water soluble linear sulfated polysaccharides which occur in the cell wall of marine red seaweeds. They are composed of an alternating idealized (A-B), structure of ct-l,3-1inked and [3-1,4-1inked D-galactose units substituted and modified to various extents (Fig. 12). Three primary forms (K-, k-, t-) of carrageenan which are commercially important are identified based on the modification of the disaccharide repeating unit resulting from the more or less regular occurrence of "masking" substituents in their structure (heterounits), chiefly sulfate hemiester groups, but also methoxy and pyruvate groups. Also the (1--->4)-linked B residues may, to a varying extent and depending on the algal source, be converted to the 3,6- anhydro form. K-Carrageenan has an idealized alternating disaccharide repeating structure of ~t-l,3-1inked D-galactose-4-O-sulphated and [3-1,4-1inked 3,6-anhydro-D- galactose, it is precipitated from whole extracts of Chondrus crispus, Euchema cottoni and Gigartma spp. and forms brittle gels in the presence of potassium ions.

os% o~

OR~

OH

b

~ o--------~

Figure 12. Structure of the repeat units of ~:-, t- and k-carrageenan. (a) K-carrageenan Ra = H, t-carrageenan Ra = SO3, (b) k-carrageenan Rb = 30% H, 70% SO3.

Page 145: Instrumental

128

While t-carrageenan shares the same ideal disaccharide structure of K-carrageenan A residues, it has an extra sulfate ester group at 0(2) of the B residues, t-Carrageenan is sensitive to Ca 2+ ions, in the presence of which it forms elastic transparent gels. The major source of t-carrageenan is Euchema spinosum. Both K- and t-carrageenans backbone structure is able to adopt a helical ordered structure (i.e. to undergo a coil- to-helix conformational transition), which may be induced by lowering the temperature and/or by adding salt to the solution [126]. This transition usually precedes the formation of a gel network (for an enjoyable review on carrageenans gelation mechanisms see ref. 127). Agar shares the same backbone structural geometry in all respects but the ( 1 ~ 4) linked 3,6 anhydro-D-galactose residues are in the L- rather than the D- enatiomeric form.

In gelling K- and t-carrageenans, the repeating sequence in the helix-forming backbone is interrupted by partial replacement of the 3,6 anhydro-D-galactose by D- galactose sulfate or disulfate residues. In t-carrageenan, for example the replacement level is typically about 10% [ 126]. These residues cannot be accommodated within the helical conformation adopted on ordering of ~:- and t-carrageenan chains but introduce a backbone "kink" in the helix structure. Most of these anomalous "kinking" residues can be converted to the helix-compatible anhydride form by treatment with alkali [126, 128], with the residual proportion of unbridged rings depending on the pattern of sulfation [126]. Alkali modification is known to substantially enhance gel properties [129].

The third industrially produced non-gelling galactan is ~.-carrageenan. It is obtained as a soluble fraction after the selective precipitation of K-carrageenan with 0.25M potassium chloride from the extracts of tetrasporophytes of the families Gigartina, Chondrus, and lridea, (although it has also been identified in Acanthophora and Laurencia spp.), t-carrageenan has a different backbone structure than the one of ~:- and t-carrageenan, it is composed predominantly by fully sulfated (1---~3)-linked residues at O(2), and (l~4)-linked sulfated at 0(2) and 0(6) and a few anhydride residues. Due to the lack of the helix-compatible (1---~4)-linked 3,6- anhydro-D-galactose residues in k-carrageenan, it does not gel, so that it is used primarily as a thickener.

It is evident thus, that apparently minor variations in primary structure, have dramatic effects on the functionality of naturally biosynthesized carrageenans such as their gelling capacity [130]. Hence, knowledge of the primary structure of commercial carrageenans is extremely useful in anticipating their behavior in food systems.

Analysis of chemical composition.

The variation in primary structure with algal source, has been studied by chemical, enzymatic, immunological, chromatographic and spectroscopic methods (refer also to

Page 146: Instrumental

129

comprehensive reviews, 131-135). It is well established that carrageenans as they are extracted from algal tissue and purified by physical methods are never quite pure. In particular, native samples of t-carrageenan normally contain a small fraction (5-10% or more, depending on the algal source) of ~:-carrageenan fraction, and viceversa [130].

General chemical analysis of carrageenans includes the quantitative determination of their basic components, namely galactose (Gal) and 3,6-anhydro-D-galactose (AnGal) units, as well as the sulfate contents. AnGal is determined using a colorimetric assay using the resorcinol reagent [136] and Gal is measured by difference after determination of total sugars by the phenol-sulphuric acid method [ 137] and calculated as galactose after correction for the AnGal content; ester sulfate content can be determined by a gravimetric method following precipitation with BaSO4 [ 138], or turbidimetrically after hydrolysis of the polysaccharide with 1M HC1 at 100 ~ for 6h. 3,6-Anhydro-galactose, galactose and sulfate contets cannot be considered as specific enough critera to establish the chemical identity of galactans. They only provide a very broad indication of the kind of carrageenan that is being dealt with. Typical proportions of these for polysaccharides from Euchemma cottoni (predominantly K-carrageenan) are 66% galactose, 34% 3,6 anhydro galactose and ester 25% ester sulphate; values for Euchema spniosum carrageenan (t- form ) are Gal 70%, AnGal 30% and 32% ester sulfate; the non-gelling ~-carrageenan is distinguished by low proportions of AnGal of ca. 5.0% and high ester sulphate contents (ca. 35%) [139].

Analysis of carrageenan identity

Detailed knowledge of the identity of carrageenans involves the following analysis: �9 Constituent sugars analysis: Gal, AnGal and anomalous residues �9 Location of ester sulphate and O-methyl masking units �9 Fine structure (determination of hybrid structures)

A number of techniques are available in order to addreess specific aspects of the chemical identity of carrageenan. A summary of these techniques along with the information derived is presented below.

Constituent sugar analysis by GC and GC/MS

Gas cromatographic methods for carbohydrate analysis involve the formation of derivatives of sufficient volatility and adequate thermal stability. Trimethylsilyl esters and acetate or trifluoroacetate esters are the most common derivatives. Mass spectrometry as commonly practicised uses electron impact most frequently as the ionization mode. Carbohydrate derivatives rarely give molecular ions in electron

Page 147: Instrumental

130

impact spectra, although molecular weights may often be inferred from electron impact spectra. At present, oligosaccharide derivatives of molecular weights of up to 1000 are convenient for mass spectral analysis. In terms of thermal stability and ease of interpretation of spectra, permethylated compuonds and TMS ethers are the derivatives of choice for mass spectrometry [3]. Such derivatives are prepared by methylation of the polysaccharide and subsequent production of the methylated alditol acetates.

Constituent sugars of carrageenan and galactans in general, have been analysed by chromatographic procedures GLC and GLC-MS [132, 140]. In contrast with other polysaccharide systems, preparation of carrageenan derivatives amenable for these techniques, involve special considerations and meticulous chemical work as briefly discussed here. The two main problems are that volatile derivatives of galactans, containing up to 50% AnGal residues, cannot be prepared directly by the above procedures (methylation ~ alditol acetates formation), due to acid-labile 3,6 anhydrogalactosyl residues are rapidly destroyed (both in the native and in the methylated form) under the harsh conditions typically used to hydrolyse their constituent monosaccharides. Also, during the methylation of carrageenan and agaroids, some of these polysaccharides are highly charged by sulphate groups and thus are insoluble in dimethylslphoxide (DMSO), and thereby difficult to methylate fully by the Hakomori procedure [141]. These methods have been substantially improved by incorporating in situ reduction during hydrolysis, using the acid-stable reductant, 4-methylmorpholine-borane (MMB) [132,142]. Under relatively mild hydrolysis conditions, virtually all the 3,6 anhydrogalactosidic bonds can be cleaved while most of the galactosidic bonds remain intact. In the presence of the borane reducing agent this leads to the production of "biitols", namely 3,6-anhydro-4-O-13-D- galactosyl-galactitols [ 140]. A range of partially methylated, partially acetylated biitols has been produced from galactans of known composition and characterised by GLC and GLC-MS total ion anlysis. From the retention times and fragment ions obtained it is possible to obtain information about the configuration of the AnGal moiety and the positions of O-methylated groups, highly valuable on the identification of algal polysaccharides.

Infrared Analysis

Infrared analysis provide a 'fmgerprint' picture of the different carrageenan types. Such technique is particularly apt for locating the site of the hemiester sulphate groups in the chain [143]. A broad band at 1230-1255 cm ~ due to S-O stretching vibrations is common to all sulphated polysaccharides and increases in size with sulphate content. The peaks at 930-94 cm ~ have been assigned to AnGal. Peaks at 820 cm ~ are characteristic of sulphate at a primary group, that is at C-6 of D-galactose; at 830 cm ~ of equatorial sulphate, that is at C-2 of D-galactose, and at 845-850 cm ~ of axial sulphate, that is at C-4 of D-galactose. A band of low absorbance at 805 cm ~,

Page 148: Instrumental

131

has been assigned to a sulphate at C-2 of the 3,6-anhydrogalactose unit [130], its presence in Euchema cottoni carrageenan, is an evidence that some t-carrageenan units co-exist with ~c- units. The bands at 1069 or 1053 cm 4 appear in K- but not in t- forms (bands VIII and IX, respectively, in Fig. 13, ref. 144). Films of solutions of the polysaccharide are made on AgCI plates or KBr disk prepared. Thin transparent films can also be prepared by drying seaweed extract at 37 ~ and mounted in cardboard with a center hole before scanning [ 145].

A 8

c I

. . . . I, J, ,

1 2 0 0 1 0 0 0

X -~ cm 4

a

t..-

A

I , _ _ | , - ,

1 2 0 0

E l i ~ b 1000

14 c m 4

Figure 13. Infrared spectra of carrageenan in water in the K+ form: (a) K-carrageenan (b) t- carrageenan (from ref. 144, with permission)

Page 149: Instrumental

132

NMR spectroscopy

The complete interpretation of 13C NMR spectra for the best known regular structures of red seaweed galactans, was described recently by comparison with the spectra of numerous model compounds [134]. K-Carrageenan from Euchema and Chondrus spp. and t-carrageenan from Euchema hybrid carrageenan were found to yield well resolved ~3C NMR spectra in the anomeric region in each case: the peak at 103.2-103.6 ppm can be attributed to C-1 of the D-galactose and D-galactose 4-sulphate residue. K-Carrageenan gave a signal at 96.2 ppm and t-carrageenan at 93.1 ppm, assigned to C-1 of 3,6-anhydrogalactose and 3,6-anhydrogalactose-2- sulphate residues, respectively (Fig. 14). In )~-carrageenan, the anomeric C-1 resonances for the D-galactose and 3,6-anhydro-D-galactose residues occur, respectively, at 103.4 and 91.6 ppm. The latter signal in particular, is different from those of ~:- and t-carragageenan above. The ~.-carrageenan spectrum also contains a peak at 64.2 ppm, which has been tentatively assigned to C-4 of the 3-1inked residue [ 146]. The presence of masking units, namely pyruvate and O-methyl substituents in carrageenans has also been identified using ~H NMR spectroscopy [147, 148].

Y a ~ -_ ~.---~.; . J

b - ~ ~ , . - 100 90 80 70 ppm

Figure 14. 13C spectra of polysaccharides from (a) Euchema spinosum and (b) Euchema cottom (with permission from Rochas et al. [ 130]).

Page 150: Instrumental

133

Carrageenan hybrid structure analysis

It is not safe to assume that the properties of a given carrageenan fraction can be understood merely in terms of its dominating structural component. The amount, chemical nature and distribution of heterounits in carrageenan are overriding factors which have a large influence on their behavior, even in those which closely approach the ideal structure [ 127]. Heterounits may, in principle, be present, either in the same chain or in separate chains. In the latter case, the sample is regarded as a mixture of different polymeric species. In the former case, the heterounits may be distributed randomly, regularly or in blocks. Hence, commercial 'native' carrageenans must always be thought as hybrids of the various ideal forms [130]. The use of enzymatic procedures coupled to ~3C NMR identification has proved successful in order to determine the complex f'me structure in native ~:- and t-carrageenans [ 130, 149]. This is an active field of research with important implications on the understanding of the functionality of commercial carrageenans. Indeed, marked synergistic effects have been reported in the rheology of t-carrageenan gels (in the K+ form) in the presence of small fractions of ~c-carrageenan, whether added or present as impurities [ 150].

IDENTIFICATION OF HYDROCOLLOID GUMS IN FOODSTUFFS

Although it is beyond the scope of this chapter, we considered pertinent to include a brief fmal section addressing analytical tests to identify the presence of gums and stabilizers in foods.

Qualitative identification of hydrocolloid agents in foods

The presence of certain polysaccharides in foods and beverages can be diagnosticated by the use of specific 'spot tests'. Thus carrageenan indicated by positive result using the methylene blue test [ 151 ], carboxymethyl cellulose using the 2,7-dihydroxynapthalene test [152] and acidic polysaccharides (i.e. xanthan, pectin) using the modified carbazole assay [ 153].

A method for the identification of natural thickening agents in food has been reported [154]. Isolated thickening agent is treated by methanolysis using hydrogen chloride in anhydrous methanol. The sugar units will occur as 1-methly glycosides and the uronic acid units as 1-methyl glycoside 6-methyl esters. The released methyl glycosides can be analyzed by capillary gas-liquid chromatography (GLC, Fig. 15). More specifically, after silylation treatment with BSA (N,O-Bis trimethylsilyl acetamide and pyridine) the volatile O-trimethylsilyl derivatives (TMS), afford quantitative yields of the constituent monosaccharides [155]. There 11 sugars and 4

Page 151: Instrumental

134

uronic acids which can be expected as monosaccharide units in polysaccharides stabilizers and their peaks units are separated to a satisfactory extent (Fig. 15).

GulA ManA GIcA

Figure 15. Glass capillary GLC chromatogram of all monosaccharide units to be expected in stabilizers (from Thier [155], with permission).

A wide range of stabilizers, which are ingredients of foodstuffs, can be identified including agar, gum arabic (LBG), pectin, carrageenan and gum tragacanth. This method yields considerable savings of time and labor when compared with former analytical approaches, however the polysaccharides must previously be isolated from the substrate in question using various clean-up steps [ 155].

Indirect detection of polysaccharides is also commonly achieved, using fluorescence methods, by detection of naturally fluorescing compounds such as low molecular weight phenolic acids (e.g. coumaric acids) which are esterified to specific structures such as the pericarp cell walls in all cereals [156,157].

Page 152: Instrumental

135

Quantitative methods

There is no general methods available of the polysaccharides analysis and the chosen method must be based on the structure and properties of the individual polysaccharides. Particularly it depends on the qualitative identification of their presence in a foodstuff, followed in most cases by hydrolysis and measurement of the sugars thus produced. The application of methods for total sugars to the isolated precipitates, form the basis of a quantitative method if suitably calibrated [28].

Pectin and xanthan are acid polysaccharides and used in many foods as thickening agent to modify the texture and the properties. An industrial method for quantitative determination of acidic polysaccharides has been developed using the hexamethylene polymer solution, (acidic polymers undergo cross-linking reactions), and read UV absorption at 235 nm [158]. Rapid quantitative assays of alginates can be achieved, using a procedure based on complexation with poly(hexamethylene biguanidinium) chloride [ 159].

REFERENCES

1 Alexander ILl. Cereal Foods World,1995; 40: 366-368. 2 Pazur JH. In: Chaplin MF, Kennedy JF, eds. Carbohydrate Analysis. A Practical

Approach. Oxford: IRL Press, 1994. 3 Aspinall GO. In: Aspinall GO, ed. The Polysaccharides, Vol. 1. New York:

Academic Press; 1982, 19-124. 4 Rees DA, Morris ER, Thom D, Madden JK. In: Aspinall GO, ed. The

Polysaccharides, Vol.1. New York: Academic Press, 1982; 195-290. 5 Pazur JH. In: White CA, ed. Advances in Carbohydrate Analysis Vol. 1, London:

JAI Press Ltd., 1991. 6 Sun SF. Physical Chemistry of Macromolecules. New York: John Willey and

Sons Inc., 1994. 7 Klockow A, Widmer HM, Amado R, Paulus A. Fresenius J Anal Chem 1994;

350:415-425. 8 Gidley MJ. In: Phillips GO, Williams PA, Wedlock DJ, eds. Gums and

Stabilisers for the Food Industry 4. Oxford: IRL Press, 1988; 71-80. 9 Gidley MJ. In: Alexander ILl, Zobel HF, eds. Developments in Carbohydrate

Chemistry. St. Paul MN, USA: American Association of Cereal Chemists, 1992. 10 Dietrich CO, Nader HB, Perlin AS. Carbohydr Res 1975; 41: 334-338. 11 Pazur JH, Kelly-Delcourt SA. Biochemistry 1985; 24: 3368-3369. 12 Whistler RL, Anisuzzaman AK. In: Whistler RL, BeMiller JN, eds. Methods in

Carbohydrate Chemistry Vol. 8, New York : Academic Press, 1980. 13 Kennedy JF, D.L. Stevenson, White CA. Starch/Starke 1988; 40: 396-404. 14 Haworth WH. J Chem Soc 1915; 107: 8-16.

Page 153: Instrumental

136

15 Bjomdal H, Hellerqvist CG, Lindgren H, Lindberg B, et al. Angew Chem Intemat Edit 1970; 9:610.

16 Morrison IM. J Chromatogr 1975; 108:361-364. 17 Fox JD, Robyt JF, Carbohydr Res 1992; 227: 163-170. 18 Harding SE, Vanun KM, Stokke BT, Smidsred O. In: White CA, ed. Advances

in Carbohydrate Analysis Vol 1. London: JAI Press Ltd., 1991. 19 Harding SE. In: Phillips GO, Wedlock DJ, Williams PA, eds. Gums and

Stabilizers for the Food Industry 7. Oxford, UK: IRL Press, 1993; 55-65. 20 Fox JD, Robyt JF. Anal Biochem 1991; 195: 93. 21 Isbell HS. In: Whistler RL, ed. Methods in Carbohydrate Chemistry Vol 5. New

York: Academic Press, 1973. 22 Boeek P, Gebauer P, Dolnik V, Foret F. J Chromatogr 1985; 334: 157-195. 23 Whitloek LR, J Chromatogr 1986; 363: 267-276. 24 Lindberg B, Lonngren J, Svensson SS. In: Tipson RS, Horton S, eds. Advances

in Carbohydrate Chemistry and Biochemistry Vol 3. New York: Academic Press, 1975.

25 Stewart TS, Mendershausen PB, Ballou CE, Biochemistry 1968; 7: 1843-1854. 26 Mader WJ. Crit Rev Anal Chem 1970; 1: 194. 27 Smith GB, Downing GV. Anal Chem 1979; 51: 2290-2293. 28 Southgate DAT. Determination of Food Carbohydrates. Barking, England:

Applied Science Publishers Ltd., 1976. 29 Kennedy JF, Pagliuca G. In: Chaplin MF, Kennedy JF, eds. Carbohydrate

Analysis. A prctieal Approach 2nd ed., Oxford: IRL Press, 1995. 30 Blakeney AB, Harris PJ, Henry RJ, Stone BA. Carbohydr Res 1983; 113: 291-

299. 31 Rittenburg JH, Smith CJ, Ghaffar A, Allen JC. In: Phillips GO, Wedlock DJ,

Williams PA, eds.Gums and Stabilisers for the Food Industry 2, New York: Pergamon Press, 1984.

32 Tikami S, Sum~ S, Schuerch C, Suzuki M. Chem Pharm Bull 1986; 34: 3933. 33 Fulcher RG, Irving DW, de Francisco A. In: Munck L, ed. Fluorescence Analysis

of Foods. Essex, UK: Longman Scientific and Technical, 1989. 34 Fuleher RG, Faubion JM, Ruan R, Miller S. Carbohyd Polym 1994; 25: 285-

293. 35 Haugland RP. Handbook of Fluorescent Probes and Research Chemicals, 5th

edn. Eugene OR, USA: Molecular Probes Inc, 1992. 36 Symons SJ, Fulcher RG. J Cereal Sci 1988; 8: 211-218. 37 Symons S J, Fulcher RG. J Cereal Sci 1988; 8:219-229. 38 Hoseney RC. In: Principles of Cereal Science and Technology. St Paul MN:

American Association of Cereal Chemists, 1986. 39 Wong DWS. Mechanisms and Theory in Food Chemistry. New York: Van

Nostran Reinhold, 1988. 40 Rapaille A, Vanhemelrijck J. In: Imeson A, ed. Thickening and Gelling Agents

for Food. Glasgow, UK: Blackie and Professional, 1992; 171-201.

Page 154: Instrumental

137

41 Atwell WA, Hood LF, Lineback DR, Varriano-Marston DR, et al. Cereal Foods World 1988; 33:306-311.

42 Englyst HN, Cummings JH. In: Cereals in an European Context. Chichester: Ellis Horwood Ltd., 1987; 221-233.

43 Ewers E. Ztschr Offentliche Chemie 1908; 14: 150. 44 Clendenning KA, Wright DE. Can J Res 1945; 23B: 131-138. 45 Lane JH, Eynon L, J Chem Soc Ind 1923; 42: 32-37T. 46 Egan H, Kirk RS, Sawyer R. Persons Chemical Analysis of Foods, 8th ed. Essex,

England: Longman Scientific and Technical, 1981. 47 Bernfeld P. In: Colowick SP, Kaplan ND, eds. Methods in Enzymology Vol 1.

London and New York: Academic Press, 1955. 48 Kidby D, Davidson DL. Anal Chem 1973, 55:231. 49 Osborne DG, Voogt P. The Analysis of Nutrients in Food. London: Academic

Press, 1978. 50 Kiser DL, Hagy RL. In: Charalambous G, ed. Liquid Chromatographic Analysis

of Food and Beverages. New York: Academic Press, 1979. 51 Sloan HR, Kerzner B, Seckel C. Prep Biochem 1984; 14: 245. 52 Eltekov YA, Strakhova NM, Kalal J, Peska J, Stamberg J. J Polym Sci Polym

Symp 1980; 68:247-251. 53 Klingler RW. Starch/St~ke 1985; 37:111-115. 54 Samec M. J Polym Sci 1957; 23: 801. 55 Klaushofer H, Berghofer E, Diesner L. Starch/St~ke 1976; 28: 298-303. 56 Osborne DG, Douglas S. J Sci Food Agr 1981; 32: 328-332. 57 Osborne DG, Douglas S, Fearn T. J Food Techn 1982; 17: 355-363. 58 Evers AD, Stevens DJ Morton ID. In: Pomeranz Y, ed. Advances in Cereal

Science and Technology. St. Paul MN" American Association of Cereal Chemists Inc., 1985.

59 Muhrbeck P, Tellier C. Starch/St~ke 1991; 43: 5-27. 60 Armstrong E. PhD Thesis, University of Ottawa, Ottawa, Ontario, 1992. 61 French D. In: Whistler RL, BeMiller JN, Paschall ED, eds. Chemistry and

Technolgy, New York: Academic Press, 1984. 62 Clark AH, Ross-Murphy SB. Adv Polym Sci 1987; 33: 57-192. 63 Gidley MJ, Bociek SM. J Am Chem Soc 1988; 110: 3820-3829. 64 Wu H, Sarko A. Carbohydr Res 1978; 61: 7-25. 65 Imberty A, P6rez S. Biopolymers 1988; 27: 1205-1221. 66 Imberty A, Chnazy H, P6rez S, Buldon A, et al. Mol Biol 1988; 201:365-378. 67 Gidley MJ, Bociek SM. J Am Chem Soc 1985; 107: 7040-7044. 68 Veregin RP, Fyfe CA, Marchessault RH, Taylor MG. Macromolecules 1986;

19:1030-1034. 69 Horii F, Yamamoto H, Hirai A, Kitamaru R. Carbohydr Res 1987; 160: 29-40. 70 Veregin RP, Fyfe CA, Marchessault RH. Macromolecules 1987; 30: 3007-3012. 71 Guennet JM. Thermoreversible Gelation of Polymers and Biopolymers. London:

Academic Press Ltd., 1992.

Page 155: Instrumental

138

72 Schoch TJ. Adv Carb Chem 1945; 1: 247. 73 Lou J, Myers MN, Giddings JC. J Liq Chromatogr 1994; 17: 3239-3260. 74 Manners DJ. Carbohydr Polym 1989; 11: 82-112. 75 Lee EYC, Mercier C, Whelan WJ. Arch Biochem Biophys 1968; 125: 1028-1030. 76 Hizukttri S. Carbohydr Res 1985; 141: 295-306. 77 Hizukuri S. Carbohydr Res 1986; 147: 342-347. 78 Anderson DMW, Weiping W. Int Tree Crops J 1991; 7: 29-40. 79 Immeson AP. In: Immeson AP, ed. Thickening and Gelling Agents for Food.

Glasgow: Blackie Academic and Professional, 1992. 80 Anderson DMW, Millar JRA, Weiping W. Biochem Syst Ecol 1991; 19: 447-452. 81 JECFA-FAO. Food and Nutrition Paper, Rome 1986; 34. 82 USFDA GRAS, Chapter 184; 1987; 1330. 83 FAO. Food and Nutrition Paper 49; Rome: FAO, 1990, 23-25. 84 Phillips GO, Williams PA. In: Nishinari K, Doi E, eds. Food Hydrocolloids:

Structures, Properties and Functions. New York: Plenum Press, 1994; 45-63. 85 Pigott JR, Sharman K. In: Pigott JR, ed. Statistical Procedures in Food Research.

Essex, England: Elsevier Applied Science, 1986; 181-232. 86 Powers JJ, Ware GO. In: Pigott JR, ed. Statistical Procedures in Food Research.

Essex. England: Elsevier Applied Science, 1986; 125-180. 87 Fleiss JL, Zubin J. Multivar Behav Res, 1969; 4:235-250. 88 Jurasek P, Kosik M,, Phillips GO. Food Hydrolloids 1993; 7:73-85. 89 Jurasek P, Kosik M, Phillips GO. Food Hydrolloids 1993; 7:157-174. 90 Jurasek P, Kosik M, Phillips GO. Food Hydrolloids 1993; 7:255-280. 91 Jurasek P, Phillips GO. Food Hydrocolloids 1993; 7:337-352. 92 Saunders RM, Becker R. In: Wickens GE, Haq N, Day P, eds. New Crops for

Food and Industry. London: Chapman and Hall, 1989; 288-302. 93 Biswas S, Biswas B, Phillips GO. Food Hydrocolloids 1995; 9:151-163. 94 Defaye J, Wong E. Carbohydr Res 1986; 150: 221-231. 95 Anderson DMW. Food Addit Contam 1985; 3: 159-162. 96 Anderson DMW, Howelett JF, McNab CJA. Food Addit Contam 1985; 2: 159-164. 97 Anderson DMW, Douglas DM, Morrison NAy Weiping W. Food Addit Contam

1990; 3: 303-321. 98 Connolly S, Fenyo JC, Vandevelde MC. Food Hydrocolloids 1987; 5/6: 477-480. 99 Randall RC, Phillips GO, Williams PA. Food Hydrocolloids 1989; 3: 65-75. 100 Osman ME, Menzies AR, Williams PA, Phillips GO, et al. Carbohydr Res 1993;

246: 303-308. 101 Ray AK, Bird PB, Iacobucci GA, Clark BC Jr. Food Hydrocolloids 1995; 9: 123-

131. 102 Menzies AR, Osman ME, Phillips GO, Williams PA. In: Phillips GO, Wedlock

DJ, Williams PA, eds. Gums and Stabilisers for the Food Industry 6. Oxford, UK: Oxford University Press, 1992; 507-512.

103 Osman ME, Williams PA, Menzies AR, Phillips GO. J Agric Food Chem 1993; 41: 71-77.

Page 156: Instrumental

139

104 Dickinson E, Galaszka VB, Anderson DMW. Carbohydr Polym 1991; 14: 373-383. 105 Connolly S, Fenyo JC, Vandevelde MC. Carbohydr Polym 1988; 8: 23-32. 106 Williams PA, Phillips GO, Stephen AM. Food Hydrocolloids 1990; 4:305-311. 107 Heidelberger M. J Am Chem Soc 1955; 77:4308-4311. 108 Strobel S, Ferguson A, Anderson DMW. Tox Lett 1982; 14:247-252. 109 Pazur JH, Kelly-Delcourt SA, Miskiel FJ, Burdett L, et al. J Immunol Meth

1986; 89: 19-25. 110 Miskiel FJ, Pazur JH. Carbohydr Polym 1991; 16:17-35. 111Yates EA, Knox JP. Carbohydr Polym 1994; 24: 281-286. 112 Williams PA, Menzies AR, Phillips GO, Smith CJ. In: Morgan MRA, Smith CJ,

Williams PA, eds. Food Safety and Quality Assurance Applications of Immunoassay Systems. Barking, Essex, UK: Elsevier Science Publishers, 1992; 385-392.

113 Boyd J, Turvey JR. Carbohydr Res 1978; 66: 187-194. 114 Smidsrod O. Faraday Discuss Chem Soc 1974; 57: 262-274. 115 Morris ER, Rees DA, Thom D, Boyd J. Carbohydr Res 1978; 66: 145-154. 116 Morris ER, Rees DA, Robinson G, Young GA. 1980; J Mol Bio119~ 138: 363-374. 117 Grant GT, Morris ER, Rees DA, Smith PJC et al. FEBS Lett 1973; 32: 195-198. 118 Haug A, Larsen B, Smidsrod O. Acta Chem Scand 1967; 21: 691-704. 119 Vreeland V, Slomich M, Laetsch WM. Planta 1984; 162:506. 120 Morns ER, Frangou SA. In: Northcote DH, ed. Techniques in Carbohydrate

Metabolism. Amsterdam: Elsevier; B308, 1981; 1-51. 121Craigie JS, Morris ER, Rees DA Thorn D. Carbohydr Polym 1984; 4: 237-252. 122 Grasdalen H, Larsen B, Smidsrod O. 1978; Proc Int Seaweed Symp, 9th 1977;

309-317. 123 Grasdalen H. Carbohydr Res 1983; 118: 255-260. 124 Thomas WR. In: Imeson A, ed. Thickening and Gelling Agents for Foods.

Glasgow UK: Blackie Academic and Professional, 1992; 25-39. 125 Stanley NF. In: Harris P, ed. Food Gels. Exeter, UK: Elsevier Applied Science,

1990. 126 Rees DA, Williamson FB, Frangou SA, Morris ER. Eur J Biochem 1982;

122:71-79. 127 Piculell L. In: Stephen AM, ed. Food Polysaccharides and their Applications.

New York: Marcel Dekker Inc, 1995;205-245. 128 Stanley US Patent 1963; 3094517. 129 Ainsworth PA, Blanshard JMV. Lebensmittel Wissenchaft und Technology

1978; 11: 279-282. 130 Rochas C, Rinaudo M, Landry S. Carbohydr Polym 1989; 10:115-127. 131 Bodeau-Bellion C. Physiol V6g 1983; 21: 785-793. 132 Stevensson THE, Furnaux RH. Carbohydr Res 1991; 210: 277-298. 133 Painter TJ. In: Aspinall GO, ed. The Polysaccharides Vol. 2. New York:

Academic Press, 1983; 195-285, and references cited therein. 134 Usov AI, Yarotsky V, Shaskov AS. Biopolymers 1980; 19: 977-990.

Page 157: Instrumental

140

135 Percival E, McDowell RH In: Methods in Plant Biochemistry Vol 2. London: Academic Press Ltd., 1990.

136 Yaphe W, Arsenault GP. Anal Biochem 1965; 13: 142-148. 137 Dubois M, Gilles KA, Hamilton JK, Rebers PA, Smith F. Anal Chem 1956, 28:

350-356. 138 Vogel AI, Bassett J, Denney RC, Jeffery GH et al. Quantitative Inorganic

Analysis including Elementary Instnunent Analysis. London: Longman Group Ltd, 1976.

139 Fassihudin BA, Williams PA. In: Phillips GO, Wedlock DJ, Williams PA, eds. Gums and Stabilisers for the Food Industry 6. Oxford, UK: Oxford University Press, 1992; 145-148.

140 Falshaw R, Furneaux RH. Carbohydr Res 1995; 269:183-189. 141Hakomori S. J Biochem (Tokyo) 1964; 55: 205-208. 142 Garegg PJ, Lindberg B, Konradsson P, Kvarnstr6m I. Carbohydr Res 1988; 176:

145-148. 143 Rochas C, Lahaye M, Yaphe W. Bot Mar 1986; 29: 335-340. 144 Belton PS, Wilston RH, Chenery DH. Int J Macromol 1986; 8:247-251. 145 Knutsen SH, Grasdalen H. Bot Marina 1987; 30: 497-505. 146Falshaw R, Furneaux RH. Carbohydr Res 1994; 252: 171-182. 147Izumi K. Biochem Biophys Acta 1973; 320: 311-317. 148Knutsen SH, Grasdalen H. Carbohydr Polym 1992; 19: 199-210. 149Greer CW, Yaphe W. Botanica Marina 1984; 27: 473. 150Piculell L, Nilsson S, Muhrbeck P. Carbohydr Polym 1992; 18: 199-208. 151 Williamson FB, Ph.D. Thesis, University of Edinburgh, 1960. 152 Strange TE, J. Ass Off Agric Chem 1957; 40 482. 153 Bitter T, Muir HM, Anal Biochem 1962; 4: 330. 154 Preuss A, Thier HP. Z Lebensm-Unters Forsch 1983; 176: 5. 155 Thier HP. In: Phillips GO, DJ Wedlock, Williams PA eds. Gums and Stabilisers

for the Food Industry 2. New York: Pergamon Press, 1984. 156 Fulcher RG, OBrien TP, Lee JW. Austr J Biol Sci 1972; 25: 23. 157 Alkin DE, Ames-Gottfred N, Hartley RD, Fulcher RG et al. Crop Sci 1990; 30:

396. 158 Kennedy JF, Melo EHM, Crescenzi V, Dentini M, et al. Carbohydr Polym 1992;

17: 199-203. 159 Kenedy JF, Bradshaw IL. Carbohydr Polym 1987; 7: 35-50.

Page 158: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 141

ANALYTICAL NEAR INFRARED SPECTROSCOPY

David L. B. Wetzel, Kansas State University, Shellenberger Hall, Manhattan, KS 66506 (USA)

SUMMARY Every day thousands of near infrared analyses are performed mostly by non-spectro-

scopists on a routine basis primarily using this technique as an inspection tool. One of the earliest modern applications of chemometrically based near-IR was in the commodity and food area. In the past three decades, use of near-IR has been due to it's, 1)speed, requiring 20 seconds or less; 2) user friendliness in that sample preparation or pre-separation is not required; 3) the fact that once the chemometric relationship is established and calibration has been done, data can be collected routinely by technicians with a minimum of training. Besides the continuous expansion of applications as near-IR has matured much attention has been given to software by 3rd party providers, instrument users, and manufacturers. Recent hardware advances and solid state detector technologies have revolutionized instrument design by making rapid electronic wavelength switching (with no moving parts) readily available with acousto-optic tunable filter monochromomators or with grating polychromator near-IR diode array systems. FT-NIR instruments, offered also by traditional FT-IR manufacturers, provide alternatives to grating monochromators for scanning or random wavelength access. Analytical near infrared spectroscopy is a useful and cost effective method of food analysis at ingredient, processing, and product stages of production.

INTRODUCTION In the past three decades, practical near-IR spectroscopic analysis has become well

established as a routine inspection tool in a number of industries. This includes agriculture and food. It is not only a fast method, but also very little sample preparation is required and even granular solids can be analyzed directly using statistically based, quantitative, chemometric relationships. Although structural information is less apparent from near-IR data than from mid-IR, a qualitative analysis inspection function is available in addition to quantitative determi- nation via a multiterm pattern recognition (discriminate analysis) approach.

The range of near-IR is from 850 nm to 2500 nm (11,000-4,000 cm-l). At the lower wavelengths or higher frequencies it is acknowledged that some electronic transitions are possible but that this is not the major source of near-IR absorption. In general, the origin of near-IR is the overtones and combination bands of fundamental vibrations in the mid-infrared spectrum from 2.5 - 15 ~tm (4,000-600 cm'l). Traditionally, quantitative infrared spectroscopy applied

Page 159: Instrumental

142

to mixtures in powered form has been assumed to be very difficult and perhaps entirely impractical for such analytical procedures and therefore, chromatography or various other separations have been necessary before determination of individual components could be done. In the mid-infrared region of the spectrum, diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy introduced by Fuller and Griffiths (1) has received considerable attention in the last 20 years. Usually spectral subtraction is used to uncover hidden features within mixtures and it is necessary to dilute the sample with solid granular KC1 in order to avoid complete saturation of absorption bands by this technique. Some general applications of near-infrared may be reviewed in Table 1. On that list, compiled in the past when near-IR was being newly developed, greater emphasis was given to the handling of solid samples by diffuse reflectance. Of course, clear liquids and slurries can be handled even more readily. Near-IR quantitative techniques are useful in many cases, but in general, it is not considered for trace analysis applications. Where components are present in the amount of 1% or more, weakly absorbing samples may be analyzed using multiple wavelengths with multivariate statistics. The convenience of sample handling, computer assistance, and additivity of near-infrared responses makes this possible. Although the subject of this text involves analytical near-infrared spectroscopy for analysis of food and beverages, originally it was applied

by industrial chemists working for Table I. Facts Concerning Near-Infrared Tennessee Eastman in the 1950's.

The work of Wilbur Kaye (2) led �9 Agricultural commodities in worldwide commerce are analyzed by the way to future activities. This

near-IR for their content of water, protein, lipid, etc. work was subsequently also re-

�9 Pharmaceuticals have been identified by applying discriminant analysis viewed by Whetsel (3) also ofTen- expressions from multiwavelength data. nessee Eastman. These industrial

�9 Rapid and timely analysis for process control in various processing chemists, faced with either neat industries is based upon near-IR methods, chemicals or highly concentrated

�9 Sample preparation prior to spectroscopic measurement is minimal even solutions, encountered strong ab- in the case of powders.

Industrial applications of near-IR include determining: �9 molecular weight of propylene and ethylene glycol polymers �9 moisture content of coal and hematite �9 textile blends of cotton-polyester and of rayon-polyester �9 finishes on textile fibers �9 amount of cross linkage in chemically modified starch �9 hydrogenation of unsaturated fatty acid esters �9 hydrocarbon mixture of n-hexane, benzene, cyclobenzene, iso-octane �9 volatiles (loss on drying) and moisture in cosmetics �9 total alkaloids, nicotine, and reducing sugar in tobacco processing �9 moisture in pharmaceutical excipients and in detergent powders

sorption bands in the mid-infrared and they moved to the near-infra- red as a way of avoiding saturation of the bands and production of non-linear quantitative relation- ships. (This approach is similar to that routinely employed by atomic spectroscopists when an emission line for one element is too strong, they merely select a weaker line.) In the case of vibrational spectros- copy, either overtone or combina-

Page 160: Instrumental

143

tion bands have greatly diminished absorptivity in comparison to their fundamentals. A British physicist named Goulden (4) applied near-infrared spectroscopy to a number of dairy products as early as 1956. He also used what he referred to as diffuse "absorptance" and published the spectra of various solids including nonfat dry milk. With perhaps few exceptions, most workers from the ranks of spectroscopists and analytical chemists prior to mid-1960's dismissed the near-IR region as having only weak (and probably uninteresting) absorption bands that overlapped. This same group also dismissed the notion of obtaining anything meaningful, let alone quantitative analysis from the diffuse reflectance procedure because the effect of scattering was presumed to complicate the issue hopelessly. One persistent agricultural engineer, Karl Norris, with the United States Department of Agriculture, and his associate, David Massey, who built the specialized instrument used by Norris, proved to be the exceptions (5).

This persistence paid off through the introduction of a new way of treating spectroscopic data. Chemometrics enabled using diffuse reflectance techniques on granular solid commodities (to avoid the use of toxic solvents such as carbontetrachloride) that produced spectra that could not be treated with a simple one-wavelength Beer's Law approach. Unlike spectroscopy of clear liquids or dilute solutions, diffuse reflectance does not have the luxury of having 100% transmission as a reference, and, therefore, an arbitrary standard reflector is used as the background reference.

Absorbance = log [Intensity (of background without sample)/Intensity (with the sample)] Multiple overlapping absorption bands that are weak in intensity require the use of perhaps multiple wavelength optical terms each with its own coefficient in an analytical equation. Furthermore, in diffuse reflectance the effect of scattering works to advantage by returning light back to the detector but it will add uncertain experimental variables by producing a multipath effect because it returns by a circuitous route (multiple bounces) once it has penetrated the specimen. Thus, the variability of the baseline must be compensated for in the equation with a baseline correction that deals with the scattering component. With these data treatment techniques that allow compensation for optical effects and with some of the basic features of near-infrared absorption that will be discussed later, modern near-infrared was rediscovered three decades ago and has found its way into a prominent position at present in applied spectroscopy of industrial and agricultural materials primarily for quantitative purposes but also to a lesser degree for identification.

SPECTRAL FEATURES OF THE NEAR-INFRARED In comparison with other optical analysis methods, let us consider the relative sensitivity

of the method, the instrument signal-to-noise ratio, and the selectivity. The sensitivity of an optical absorption spectroscopic analytical method is dependent on the probability of a transition from the ground state to an elevated energy state within the molecule. Ultraviolet has a high sensitivity, followed by mid-infrared. In both cases, the absorptivity coefficients are high. In contrast, the

Page 161: Instrumental

144

sensitivity of near-infrared is much lower, and the absorptions are weak. The energetic difference between high energy vibrations of excited molecules and the energy state at the lower vibrational levels is less. Furthermore, the probability of vibrational excitation into the higher energy state in the near-infrared is less than it is in the mid-infrared. As will be discussed later, this apparent weakness is not necessarily a disadvantage and in fact, it makes possible some of the additivity required to process the data to produce quantitative results.

The instrument signal-to-noise ratio (S/N), although it cannot compare with the visible region of the spectrum where photomultiplier detection is used, is nevertheless much, much greater than that of the mid-infrared, the ultraviolet, or the far-infrared. Because of the relatively low sensitivity of near infrared, high S/N operation is a necessity. If one is making analytical decisions based on a few milliabsorbance units of difference in the spectra of various samples then the noise level must be held down to a few microabsorbance units. This instrumental requirement exceeds that of most other optical instruments.

Selectivity permits considering absorptions from the analyte in a specific part of the spectrum that are not affected by the absorptions of a molecule of the matrix or possible interfering material that is present in the matrix. In contrast to the mid-infrared, which is famous for qualitative information content and for the ability to relate specific absorption bands to molecular structure, near-infrared rates in selectivity about one-third of the value as that of mid-infrared. The selectivity of near-infrared, however, exceeds that of ultraviolet, visible, and far-infrared spectroscopy.

Figure 1 shows absorption spectra in the most commonly used portion of the near infrared region. These absorption spectra of 10 mixtures of organic fluids are plotted as Absorbance against

O. 7 0 0 0 .

0 , 6 0 0 0 .

0 . 5 0 0 0

tu u z < o . 4 0 0 0 -

o In (D < 0 . 3 0 0 0 -

0 . 2 0 0 0 '

O . t 0 0 0

0 , 0 0 0 t ~ ~ ! - - . - - - - - - t - - - - - a - - - - - - I ~ ! " ; ' : ~ - - 1 2 0 0 . 0 1 4 0 0 . 0 t 6 0 0 . 0 t 8 0 0 . 0 2 0 0 0 . 0 2 2 0 0 . 0 2 4 0 0 . 0

HAVELENGTH

Fig. 1. Spectra of mixtures of organic fluids from Kansas State University research model Near-IR Acousto-optic Tunable Filter Spectrometer.

Page 162: Instrumental

145

wavelength from 1100 to 2500 nm. Note that there are four distinct regions of the spectra going from the strongest bands at the right in the region above 2100 nm where the most prominent CH combination band of hydrocarbons is found. Of the 10 spectra that are superimposed, a drastic excursion in the absorbance between 2100 nm and 2200 nm is noted. A reverse excursion occurs at the taller band in the region of 2250-2500 nm. A reciprocal arrangement is noted in that there is a decline in the band at 2300 nm when the band at 2150 nm increases. In this particular illustration, the two bands referred to are due to combinations of aromatic CH and aliphatic CH and when among the mixtures of hydrocarbons there is an increase in the one form there is a corresponding decrease in the other form. In the region of 1600-1800 nm there are overtones of the fundamental CH vibrations. Again, an excursion is noted among the 10 spectra that are superimposed. The shape of the band that occurs in this region is changed dramatically and the positions of the three prominent peaks have shifted depending on whether there is more aromatic or aliphatic hydrocarbon present. Note that when plotted on the same scale as the first combination and first overtone, the differences on the second combination at 1400 nm and the second overtone in the 1100-1200 nm regions appear to be very small. It should be mentioned that upon scale expansion, these regions of the spectrum (1100 - 850 nm), where the resulting absorption for the higher combinations and overtones occur, are also useful.

In food and beverage analysis, we are concerned not only with hydrocarbons but also with protein (amides), carbohydrates, lipids, and moisture. When these materials are found in a typical food matrix and diffuse reflectance spectra are run, the contributions of individual constituents are less obvious than when we look at the spectra for known mixtures of pure chemicals. In Figures 2 - 5 we observe the spectra of several hydrocarbons in the mid-infrared region for both aliphatic and aromatic hydrocarbons. The unsaturation is readily apparent in the spectrum of benzene by looking at the bands at 3037 and 1480 cm -1. The fundamental vibrations at the longer wavelengths (higher frequencies) of the mid-infrared spectra will not appear in the near-IR spectrum. However, the CH vibration occurring at 3037 cm -1 from the CH attached to the carbon-carbon double bond is at a sufficiently high frequency that there will still be measurable absorption in the near-infrared that is observed graphically when scale expansion is used. Note also in the region of 2927 cm -1 and 2862 cm -1 are the fundamental absorption bands of CH2 and CH3. In the interpretation of mid-infrared spectra, the relative population of CH2 and CH3 will tell us whether the structure is linear with many CH2's and only terminal CH3, or whether many branch chains are presnet giving rise to more CH3's and less CH2's.

Now let us examine the near-infrared spectra of some simple hydrocarbons obtained on a Fourier transform near-infrared (FT-NIR) instrument. In a spectrum of hexane (Figure 6) plotted in wavenumbers (cm-1), we see the same four regions of CH bands that were observed in Figure 1. In hexane, we have CH2 and CH3 groups present. There are also carbon-carbon bonds. The contribution of the carbon-carbon fundamental vibration is not observable as a harmonic in the

Page 163: Instrumental

146

100.0.

9o.oo 8o.o0 7o.oo 60.00

.5O.OO

40.00

30.00

20.00

XT lOO.O~

95.00~

90.00~

80.00.

75.00-

70.00-

65.0G

, , , , , 1

Wovenumber Ccrn-1)

w ~ n ~ , t , ~ ( ~ - 1 )

100.0-

95.0(

90.0(

8,5.00-

80.00

75.00-

70.00-

6,5.00

Wovenurnber {a'n-1)

100.1~

95.1X~

~.~ oo.~ 75.0ff

70.00-

65.00.

60.00

W~numl~r Co'm- 1 )

Fig. 2. FT-IR spectrum of hexane (transmittance). Fig. 3. FT-IR spectrum of oenzene. rig. 4. FT-IR spectrum of toluene. Fig. 5. FT-IR spectrum of xylene.

near-IR spectrum of hexane, and, thus, we are simply counting CH's and making a slight dis- tinction between the CH2 and CH3 intensities. The place to look for the slight distinction is in the 6000-5500 cm -1 region. In contrast, the spectrum of benzene, shown in Figure 7, which has 5 aromatic CH's, has a tall band in the region of 4750-4500 cm -1. Also the band at 6000 cm -1 is shifted and has a distinctly different shape than that from the straight chain hydro- carbon hexane. Examining the spectrum of toluene (Figure 8) where one of the aromatic CH's of benzene have been replaced by a methyl group with its three aliphatic CH's, we observe a mixture of aromatic and aliphatic CH's and it is readily apparent that the toluene spectrum is more like the benzene spectrum than the hexane spectrum. In xylene (Figure 9), two aromatic CH groups had been replaced by methyl groups with the introduction of six aliphatic CH's. Thus, the spectrum of xylene has become more like hexane than the original benzene.

By plotting the spectra of liquids with an expanded scale and plotting them linear in wavenumbers, we see that the early presump- tions of spectroscopists is incorrect and that the weak bands are not necessarily uninteresting nor are they useless. In dealing with food products, the health of heart patients (where heart disease is the biggest killer) is concerned with the degree of unsaturation of fats and oils. When we compare the spectrum of oleic acid (Figure 10) to that of hexane, distinct similarities are noted due to the C18 hydrocarbon chain versus the shorter chain C6. There are two things to note in contrast; first of all the CH2 to CH3 ratio affects the shape of the band between 6000 and 5500 cm -1 and more importantly there is a band

Page 164: Instrumental

147

2 . 1 1 1 1 1 - . . . . . . . . . . . . . . . . . . " " " ' "

in the same region where we observe aromatic character due to the presence of the double bond ~.~ in oleic acid. Oleic acid is designated as C18:1. For the 18 carbons in the chain there is one~ ''| double bond present. In Figure 11 a greater~.0,, degree of unsaturation shows up in the spectrum of linoleic acid because there are two double .3~ ~ ~ 1 bonds instead of the single one found in oleic ~

- - 0 . ~ 0 . , , , �9 , �9

acid. Because of the high signal-to-noise ratio, ~*. �9 / ~ . " ' i ~ l . " i~. 2 . ~ . _~l in good quality near-infrared instruments, it is2"~'~ . . . . . . . . . . . . . . . . . . . . . . . possible to scale expand the region at approxi - ' -~1 ~ mately 4600 cm -1 and to quantitate the differ- ences and use these data to determine the iodined'2~ | q : 1 . r

value (amount of unsaturation) of the fat or oil.,~.0t~ A cursory look at the spectrum of corn oil

L (Figure 12) plotted on the same scale as the oleic .~ and !inoleic acid spectra, readily shows that the_, . . . . . . . . . . . . corn oil has unsaturation nearer to that oflinoleic ~*- ~ 7***. " i~. 2 . ~ . c~-t

2 . 1 ~ . . . . . ' . . . . . ' " " ' " " "

than of oleic acid. In the early days of modern near-infrared "~1

spectroscopic analysis, the author of this chapter did successful calibrations of fats and oils to~t2~ iodine value obtained by fatty acid methyl ester~.0t,~ gas chromatographic data. Solid fat index data were also used, as well as average chain length . ~ J determined from high performance liquid chro-_0 , ~ , - , - - - _ _ matography data. All of these oil analyses were " ~ " " i~. " ~ . ~ " " ~ " " ~ ' ~-~ successful, and all of them were due to absorp-21~ 1 . . . . . . . . . . . . . . . . . . . . . . tions in the region that we are presently examin- , . 6 ~

ing. We have contrasted these to spectra of other i 1.241~

unsaturated materials such as toluene, xy~ene,~ and benzene and the industrial samples found ln~.0~0." g " Figure 1.

The amide group that is present in protein "~ produces an NH stretch absorption band that appears in the mid-infrared spectrum _, ~ . ~ . " ~ . " i ~ . " ~ . " ~ . "~-~ at Fig. 6. FT-NIR absorbance spectrum of hexane. 3280 cm-l(Figure 13) and strong amide I and II Fig. 7. FT-NIR spectrum of benzene. Fig. 8. FT-NIR spectrum ot to.mene. bands at 1650 and 1550 cm -1. Examination of Fig. 9. FT-NIR spectrum ot xylene.

Page 165: Instrumental

148

2. | 0 0 ' , . . . . . . . . . . . . . . . . . . . .

! .670

!.240

. 8 1 0

the near-infrared spectrum of butylamine (Fig-

ure 14) in contrast to that of hexane showed the

presence of additional bands near 5000 cm- 1 and 6500 cm 1 . These are obviously near-infrared

manifestations of the fundamental NH stretch-

ing vibrations in the combination and overtone

�9 =* [ ~ ,.j forms. These bands are in addition to the famil-

-,.~ ~ _..J ~ ' - - - ~ iar CH stretch combinations and overtones.

8=, . " ~ . " ~ . ' " ~ . ' ' ~ . ' " ~ . 'c,-i Figure 15 shows the mid-infrared OH stretching 2 . t 0 0 . . . . . . . . . ' , �9 � 9 . . . . . . . . .

vibration at 3300 cm -1 in the spectrum of an

,.~,o alcohol. The near-IR manifestation of this ap-

pears in 1-propanol and 1-octanol spectra in

i .2,o : , . F i g u r e s 16 and 17 at approximately 4750 cm "1

.,to and again at 6300 cm 1 . Note also that the

relative prominence of the OH band compared

�9 ~ / ~ e j to the CH band in the combination region is

-0.~ ~ f l "-----" greater when one OH and three carbons are =oo. " " ~ . ' " ~x]. ' ' i~. "" ~_~i " +-;~. " ~ t present versus one OH and eight carbons. Ad-

2 . t 0 0 . . . . . . . . . . . . . . . . . . , , ,

ditional differences are observed in the 6000- i.67, 5500 cm -1 region in terms of the band shape.

This, fur thermore, is due to the relative number t . 2 4 0

, . o f methyl and methylene groups on the three-

i.m~ carbon alcohol versus the eight-carbon straight

chain alcohol.

�9 ~ Now that we have looked at spectra of

-0.~ liquids of simple chemicals, we are better pre- == ' ' imd.' " ~ d . ' ' ~x~.' ' ~=d.' " iod . 'c~t

x-r . 2.tooU . . . . . . . . . . . . . . . . . . . . . 1 0 0 .

90. 1.6"/O-

80.

70. t.z,lo-

ii + . 3 8 0 -

. . , , |

35oo x~o ~mo ~c~ ,~'oo ,ooo _,.~ w . . . . . b,,C:m-;) =~J~"" imd."" ~ . ' " imL" " ~X~.'" ;=d. "CM-1

Fig. 10. FT-NIR spectrum of oleic acid ~one C =C). Fig. 14. FT-NIR spectrum of butylamine. Fig. 11. FT-NIR spectrum of linoleic acid (two C =C). Fig. 12. FT-NIR spectrum of corn oil. Fig. 13. FT-IR spectrum of wheat gluten (NH 3300 cm").

Page 166: Instrumental

149

pared to examine the spectra obtained from com- x, modities that are mixtures of many materials. ? ~ ~ Figure 18 shows the diffuse reflectance spectra of

granulated solids. One spectrumisofanoil seed i. 1 tl and the other is of a cereal grain. Although these spectra are plotted in wavelength, as are most of +0.o~,i-~ the spectra obtained prior to the involvement of 1 FT-NIRin the near-infrared region, the bands due ~ xi~ " 2~ ..... 2~ r 1/~ ~ to the CH vibrations are readily apparent. The ,,,.~ r176 oil seed contains lipids; it nevertheless, has long 2"** t . . . . . . . . . . . . . . . . . . . . . ! chains of C16 to C18 carbons and their CH's ,~1 1

A

produce what the near-infrared analysts refer to t ,,,.11 i as the oil bands. A pair of bands appears at~"~*~ I/~ z approximately 2310 nm and this pair is repeated~ mo~ I~ I i in the region of 1700 nm. These same bands are ~ A I i recognized as those discussed in the previous ~ ~ ~ + / ~ i figures whether they were plotted by wavelength + ~,,

'~ . " ..... imod."" +rod.' " i~ ."" ~1." " ;+oo+. c.-:t or by wavenumber. The figure shows prominent bands at 2050 nm and at 2180 nm for the oil seeds 2"~I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . which also happen to be high in protein as evi- ,.m~ It 1 denced by their average protein value shown in ~ I~. I

�9 , h t 2 Tablell. Cereal gralns are known to have a h,g ~ 2 ~ I'~ 1 '~ carbohydrate content, and the contribution ot~.,,q + 1 carbohydrate results in the large band at 2100 nm. ~ This band is so strong that the contribution of the -~ / ~ _ _ _ f ~ t protein bands just described are nearly obscured_, ~_ _1

mod." " imd." " +oo+." ' imo+." " ~od." " kn+. t:.--:t by the contribution of the carbohydrate. In spite of this visual fact, equations are routinely pro- duced from the digitized data that reflect the difference in the slope, particularly at the region of 2180 nm vs. 2100 nm. In fact, in an analytical equation, both the 2100 nm and the 2180 nm

Table II. Composition of Wheat and Soybean Starch Protein Li0id Fiber (%) (~) (%) (~)

Wheat 70 14.0 2.0 3.5 Soybean - 40.0 21.0 5.5

.s . "~

.5

, t ,

, 3 .

.t i; w,,,-te,,au, ( ~ ) LL

ig. 15. FT-IR spectrum of 1-octanol. !g. 16. FT-NIR spectrum of 1-propan, ol. tg. 17. FT-NIR spectrum of i-OC ,t~Ol. ig. 18. NIR spectra of soybean (top~ and wheat (bottom).

Page 167: Instrumental

150

0.090

0.060

0.040

O.Ok~

a.Ol~

;ii;;l i

100110 ~ 9000 ~ BOO0 ~ 7000 ~ 50(10 ~ ~ m ~ Ic~ l

(____

0.~0 O.llO 0.100 0.090 O.OaO 0.0~0 O.mtn

0.0'30 0.040 0.11130. / / ~

--0.020

wavelengths typically are used because with a high protein ground grain or flour the 2180 nm goes up and the 2100 nm declines. Typically, an equation for protein determination in a cereal grain will have a positive coefficient times the optical value representing the protein and a nega- tive coefficient at the wavelength representing the carbohydrate. To complete this determina- tion, at least one more wavelength term is usually added to adjust for the baseline effects, particu- larly when dealing with granular solids or other causes of scattering. When a scanning instru- ment is used that is capable of producing a full spectrum, there are other statistical means avail- able for looking at the entire pattern and produc- ing quantitative results as well. It should be pointed out that at least 80% of all qualitative near-infrared analyses performed now are done with filter instruments with which a group of discreet wavelengths is used to produce terms for a multi-term analytical equation.

In the previous text, we have seen that it is possible by scale expansion of the near-infra- red spectra of hydrocarbons and other simple chemicals to show relatively sharp peaks in the near-infrared spectra that have their origins in the mid-infrared. With a grating monochroma- tor scanning instrument near-infrared spectra typically are plotted in wavelength rather than wavenumber. The plotted wavenumber spectra that we have shown for the hydrocarbons in Figures 19 through 22 serve as a context for examination of the spectra of wheat gluten, wheat starch, cellulose, and wheat germ that

, ,~ ,5** ,~ have OH stretching absorptions at 5150 and kll--tl cm -1. Fig. 19. Baseline corr. FT-NIR spectrum of wheat gluten. 6920 Unlike the spectra of liquids, these

Fig. 20. Baseline corr. FT-NIR spectrum of wheat starch.were obtained in a diffuse reflectance mode and Fig. 21. Baseline corr. FT-NIR spectrum of cellulose. Fig. 22. Baseline corr. FT-NIR spectrum of wheat germ. had serious baseline incline from low to high

Page 168: Instrumental

151

wavenumbers and a highly upward displaced baseline. The four bands observed on the spectrum of hexane in Figure 7, can serve as a marker for the first CH combination at the extreme right (4030 cm'l), then the first CH overtone (5500 - 6000 cm-1); the weak second combination (near 7300 cm-1), and lastly the weak second overtone at 8000 - 8500 cm "1 in the figure. With these spectral landmarks in mind, let us examine the baseline-corrected spectrum of fractions of the common commodity, wheat. In Figure 19, we observe the characteristic amide groups at 4611 and 4865 cm -1 (approximately 2180 nm and 2055 nm). Examination of the spectra of starch (Figure 20) and cellulose (Figure 21) show that the bands for the amide groups are absent. Obviously, the well-known success of determining protein in wheat, whether it is in ground whole wheat or in wheat flour, is due to the presence of these amide groups shown in the gluten spectrum and their absence in the background matrix material of mostly carbohydrates. A strong bands occurs at 4762 cm -1 in the spectra of both carbohydrates (starch and cellulose).

The practical utility of near-infrared used to examine wheat milling fractions for the presence of non-endosperm material is evidenced by the difference between spectral features of cellulose and starch. Two bands occur for cellulose at 4240 and 4388 cm -1, whereas for starch the main absorption band is a doublet centered at at 4388 cm -1. Most of the lipid content in wheat is found in the wheat germ. Figure 22 shows the spectrum of wheat germ in which the carbohydrate band is diminished in comparison to the magnitude in starch and a CH overtone band appears at 5810 cm -1. At high lipid content, a second CH combination bands appears at 4300 cm -1. The baseline-corrected scans here were produced from an FT-NIR instrument equipped with a fiber optic probe that was dipped directly in the granulated solid sample. The purpose of baseline correction is to allow for scale expansion, so that minor peaks or minor differences of major peaks can be observed. Whenever a serious baseline slope occurs, much of the vertical scale is consumed with the shift in the baseline. Additionally, a plot linear in wavenumber is advantageous for discussing the theory and origin of a particular near-infrared spectrum in reference to its mid-infrared counterpart. Even multiples or fractions of corresponding frequencies are readily observed from these linear plots.

Because most collections of near-infrared spectra obtained on grating monochromator instruments are expressed in wavelength, most of the rest of the spectra presented in this chapter will be displayed in that manner, and when this is done, we will refer to particular bands by wavelength. It is likely that this dual terminology will persist for some reasonable period of time, because old habits are difficult to change. For this reason, we ask the indulgence from the reader.

WHY NEAR-INFRARED ANALYSIS WORKS So far in this chapter, we have presented near-infrared as a normal extension of the

mid-infrared spectrum and we have gone out of our way to show the sharp absorption bands of pure chemicals to prove to the reader that such absorption bands exist. At the time of this writing,

Page 169: Instrumental

152

near-infrared sessions appear on the programs of national and international spectroscopy confer- ences. Near-infrared spectroscopy finally has come into its own. This was not always the case. More than a decade ago, this author described near-infrared as a "sleeper" among spectroscopic techniques (6). It was stated that it is a sleeper because "it is unknown, illogical, or presumed a priori to be illegitimate by spectroscopists and analytical chemists". At that time, it was used almost exclusively by workers in the agriculture and food areas. Seldom were there complete spectra available to examine because only filter instruments were used. When they were, one observed only some nonspectacular broad and overlapping bands. In a diffuse reflectance mode of solid samples, the bands were broadened considerably, and the baseline slope was a confusing feature. If one had diffuse reflectance spectra of high protein wheat flour and lower protein wheat flour plotted as the log 1/reflectance vs. wavelength, the difference in the protein level between the high and low protein samples was hidden within the width of the pen used to plot each spectrum.

Typically the near-infrared analyzers available were filter instruments, and they were treated as a mysterious black box, because the coefficients on the analytical equations were produced purely by statistical means. Little effort was made to communicate the background of these absorbance differences or to relate them in a spectroscopic manner to their origins. Quite often, the purely statistical approach would turn up a useful correlation between some region of the spectrum (or a particular filter in a filter instrument) and some property of the material with no apparent understandable relationship that an analytical chemist or spectroscopist could cling to. People who sold and used early near-IR instruments took a rather cavalier attitude toward the statistically established method for which few theoretical explanations were provided. Fortu- nately, more than a decade ago, a few classical spectroscopists were brought into the field and because of their established reputations and prestige, other professional spectroscopists began to consider that near infrared was perhaps not a mysterious black art but, in fact, did have a scientific basis.

It is the nature of absorptions in the near-infrared to be weak since, as we have mentioned, they consist of overtones or combinations of fundamental vibrations. The subtle differences among samples previously referred to require a careful measurement of the signal. Near-IR is concerned with observing differences between two or more samples in milliabsorbance units. When this is done, it is meaningful only if the noise level is kept to a few microabsorbance units. Such instruments require more stringent control for routine spectroscopic quantitation. When solid sampling is used, diffuse reflectance requires special consideration in areas of the optical design, operation sequence, sample handling, data accumulations, and statistical treatment.

Having examined the near infrared spectra of simple chemicals and compared them to their mid-infrared spectra, we note that a few simple fundamental vibrational bands in the mid-infrared region of the spectrum of a particular compound will produce multiple overtones and multiple combination bands. The overtones yield many higher frequency bands in the near-infrared region.

Page 170: Instrumental

153

These overtones from different fundamentals are broader and will tend to overlap. Therefore the interpretation is much more difficult. The mid-infrared region is well known as a valuable tool for obtaining structural information. In the near-infrared region such structural information is obscured. We have demonstrated with simple hydrocarbons that some structural information will explain subtle differences in the near-infrared spectra. Nevertheless, structural information is relatively obscure for near-infrared when comparing it to mid-infrared. In the mid-infrared, decades of data collection have yielded huge libraries of mid-infrared spectra and dedicated workers have compiled catalogs of absorption bands in reference to certain functional groups. Information about mid-infrared absorption frequencies of certain functional groups is helpful in knowing where to look in the near-infrared for overtones. Analytical information also can be obtained even from components that do not absorb in the near-infrared by observing a shift in the frequency of known bands due to the influence of neighboring molecules.

Workine with Weak Absomtion Bands v

Weak absorptions in the near-infrared have been considered as shortcomings for this region of the spectrum in the past. Instrumentally this is true, but relative absorption strength also serves as a convenient self-limiting factor to restrict which vibrations are observed. We stated earlier that a few fundamentals will produce many overtones and combinations. Fortunately, not all of the overtones or combinations are observed, because the energetic self-limiting factor simplifies the spectrum. For example, a fundamental vibration occurring at 15 lam with overtones at approximately 7.5, 5.0, 3.75, and 3.0 is not likely to be observed in the near-infrared because the fifth or sixth overtones lack intensity. Weak absorption in the near-infrared provides selectivity. The commonly used region from 1000 - 2500 nm (10000 - 4000 cm -1) contains overtones of fundamental vibrations no higher than 5 to 8 ~m depending upon the intensity of the fundamental. The long wavelength end of the mid-infrared beyond 8 ~m (1250 cm -1) does not contribute to the near-infrared. This means that the overlapping bands in the near-infrared produced by many combinations of overtones although spectroscopically complicated are from only a few molecular groups. In the near infrared we predominately see the result of vibrations of light atoms that have strong molecular bonds.

The following equation shows the relationship of the frequency (v), expressed in wavenum- bers, to the force constant (f), expressing the strength of the chemical bond and to the reduced mass which is related to the product of the masses (m) of the vibrating atoms divided by the sum of their masses.

f

f -21c. / /"mi-m2 ,~ ~ 1 + m 2 /

In the near-infrared we predominately see the results of vibrations of light atoms that have strong molecular bonds. If the chemical bond is weak (low force constant) or the atoms are heavy (the products of their masses is great) the vibrational frequency is low and its overtone will not be

Page 171: Instrumental

154

detectable in the near-infrared. Therefore, we primarily see chemical bonds containing hydrogen attached to atoms such as nitrogen, oxygen, or carbon thereby limiting the chemical structures that are observable to fairly simple ones that are common in many organic compounds. There are also big differences in the magnitudes of these absorption bands. Overtones and combinations of the OH stretching vibration are fairly strong. OSi vibrations are very weak. This relationship indicates that analyzing water in the presence of sand should be readily possible, but detecting sand in a matrix of water is highly unlikely.

These weak overtone and combination bands are more subject to their environment than the fundamental bands resulting from the same vibration would be. Examination of the equation that shows frequency as a function of force constant and reduced mass makes this obvious. For a given vibration of two atoms bound together with a chemical bond, the masses of the atoms remain constant, but the force constant is subject to the environment of the chemical bond that is acting as the restoring force. Therefore, the overtones are more subject to the environment than is the same fundamental. A slight perturbation in the bonding scheme causes small changes in the fundamental but drastic frequency shifts and amplitude changes in the near infrared. Salinity is determined by the effect of salt in water on the absorption band for the OH of water. The competition of these ionic species thus affects the force constant that restores the vibrational position of the hydrogen and oxygen atoms with respect to each other. Since the weak bands in the near-infrared are broad and overlapping, spectroscopic resolution is usually not a problem, but reproduction of the same wavelength is essential for quantitative analysis. The practical result of this is that numerous regions occur in the near-infrared where wavelength reproducibility is high, signals are maximized, and noise is minimized. Then the optical responses are sensitive to the environment of the absorbing molecules and the number of those molecules present. Thus, quantitative measurement can be made and successfully correlated to chemical data obtained by other means. From these data and application of a suitable statistical relationship with appropriate constants, determination of analyte concentrations of unknowns can be made with surprising Succes s .

An important spectral feature in the near-infrared is that the overtones occurring at higher frequencies, which are produced by the same chemical bond, tend to have much weaker absorptions than the fundamentals. A look at the spectrum of water shows how each successive harmonic has a drastically reduced absorption, going from higher wavelengths to lower wavelengths. For any given compound that has fairly intense bands in the vicinity of 2-2.5 micrometers, by the time a harmonic wavelength at 1 micrometer is reached, the bands are so weak they can barely be detected. This gradation of intensity from strong bands at long wavelengths to weak ones at short wavelengths is typical for all of near-infrared spectroscopy.

In the infrared region a slight shift occurs for the vibration of a particular atom if it is in a different environment. Because the frequency depends on the force constant, it is not surprising

Page 172: Instrumental

155

that the force constant would change with perturbation of the bonding by the presence of other competing groups. Thus, in the infrared and the near-infrared, interpretation is aided by knowing that although the methyl band is supposed to appear at exactly 1470 nanometers, it actually can appear shifted from that location. The shift observed depends on the nearest neighbors to the group. Consider that a molecule vibrating in response to electromagnetic radiation is trying to vibrate freely, but in actual fact, the molecule vibrates in its surroundings. Constraint in its ability to move freely causes a shift in its absorption spectrum. Water, for example, has a strong band at 1900 nanometers. If approximately 5% salt is added, the band suddenly occurs at 1980 nanometers. It is well known that salt has no absorption in the near-infrared, yet the salt can be detected by the effect on absorption of water, whose bands shift from one location to another. The use of such shifts often explains why near-infrared analysis works to detect and quantitate compounds that do not have near-infrared absorption bands to start with. It is analytically sufficient for the analyte to merely affect the absorption bands of another molecule in the mixture that makes up the sample matrix.

FUNDAMENTALS OF QUANTITATIVE ANALYTICAL NEAR-IR SPECTROSCOPY

Absomtion Effect In order to obtain quantitative results on the composition of samples, we want to perform

optical measurements directly related to the composition. Primarily, we are concerned with the phenomenon of absorption of radiation. However, when we are doing measurements on samples, there are many modes of interaction of radiation with the sample. If the sample is simply illuminated with one wavelength of radiation after another, one at a time, and the variation of transmission with wavelength is measured, the spectrum is obtained. The absorption intensity is a function of three factors. Absorbance (A) is defined as the log of 1/transmittance (T) of the sample. A form of Beer's law states that A =abc, where a is the intrinsic constant of the material in question or absorptivity coefficient, b is the thickness of the sample, and ~: is the concentration of the sample. This intrinsic constant (absorptivity coefficient) of the sample is an expression of the sensitivity of an absorption measurement at a particular wavelength. The thickness of the sample should be held constant. Note that in samples where considerable light scattering occurs, maintaining constant thickness is sometimes a challenge. The concentration is the number to be determined from this measurement. In diffuse reflectance, b and c quite often will vary together during any given measurement. Thus, both terms will affect the perceived measurement recorded as absorbance.

Refractive Index Effect In pursuit of quantitative measurement of the absorption phenomenon, other optical modes

of interaction with the sample must be considered. One of these is the refractive index of the sample material itself. The refractive index of a sample will differ at different wavelengths. As

Page 173: Instrumental

156

the spectrum is being scanned for absorption, another response will be obtained for refractive index. The refractive index increases very sharply and then decreases sharply in the region of the absorption band. A change in refractive index in the sample affects the measurement by affecting surface reflection from the sample. Diamonds, for example, which have a very high refraction, would have very high surface reflection. On the other hand, glass, which has a much lower refractive index, will have a much lower reflection. Particularly when a sample is being measured in a reflectance mode, variation in reflectance will occur that is not due to absorption of light but to variation in the refractive index of the sample itself.

Absorption has one property that is exceedingly important for near-infrared analysis. The absorption term, usually expressed logarithmically as Absorbance, must have the property of additivity. If five different compounds are absorbing at the same wavelength, it must be possible to calculate the Absorbance total value by summing up the individual Absorbances of each compound. Under ideal circumstances, when working with solids, it may be possible to achieve Absorbance additivity, providing that reasonable linearity occurs for each of the absorbing species within the concentration range in which they appear.

When dealing with solid samples, it is most unfortunate that their refractive index effect does not share the additivity property that we are trying to achieve with respect to Absorbance. In a mixture of compounds A and B, the Absorbance of the whole is the Absorbance of A plus the Absorbance of B, assuming that the additivity is adhered to. The refractive index effect can produce what is called anomalous dispersion. This produces a change in reflectance. Unfortu- nately a very complex relationship exists for combining the effects of those components. Another mode of light interaction with the sample that produces variation is reflection. The amount of reflectance of an incident ray normal to the surface is a function of the refractive index of the material. For example, a material with an index of refraction of 1.5 would reflect approximately 4 % of the light, whereas a material with an index of refraction of 2 would reflect as much as 11%. Thus, differences in indices of refraction of analyte vs. matrix, or of calibration samples vs. analysis samples, might produce variations that are quite significant. The whole area of reflectance is of major consideration when scattering is high compared to absorption. For the present, it is sufficient to keep in mind that one of the results of change in refractive index with wavelength is that it also produces a difference in reflection. This can become a serious problem for doing multicomponent analysis and making measurements at a number of different wavelengths.

Scattering Effect The other mode of interaction of radiation with the sample is scattering. Scattering occurs

when radiation hits the sample, enters into the body of the sample, and comes out in very many directions. Such scattering back toward the direction in which the radiation came is referred to as diffuse reflectance. In a slurry in which a considerable amount of particulate material is in a liquid or in a pulverized solid (a powder sample), reflection occurs at the various surfaces. This

Page 174: Instrumental

157

reflection occurs in random directions dependent on that fraction of the surface where the ray struck, and the result is randomization in the direction of the returning beam

Refraction off of the individual particles again changes the direction of the beam. As the particles get very small, diffraction also could occur where the size of the wavelength of light is comparable to the size of the particles. In such a case, the amount of scattering that takes place has a very strong localized maximum. It is readily observed that the scattering intensity for a sample increases as a function of particle size. This increase is gradual and as the particle size approaches the wavelength, a strong peak occurs in the vicinity where the wavelength dimension starts and then it diminishes to almost nothing. In most cases, particle sizes of wavelength size dimensions are not readily achievable. In the near-infrared, the wavelengths under consideration are from 1 to 2.5 micrometers. Even in this case, a very fine powder is needed to use diffuse reflectance. In general, in near-infrared reflectance, the finer the powder, the better the scattering. There are some exceptions. In near-infrared analysis of milk, if milk containing particles is homogenized, it becomes more transparent, not less transparent. So there are at least a few exceptions to the rule that smaller particles are better for doing diffuse transmittance or diffuse reflectance measurements.

Virtues of Near-IR Before considering the virtues, let us first point out the apparent disadvantages of the

near-infrared region of the spectrum and see how some of these can be overcome. The first disadvantage is the complexity of the spectrum, where so many combinations of bands are possible at any given wavelength. The spectrum is overfilled and everything overlaps, so it is very difficult to isolate just the band of the material to be measured. This overlapping also makes interpretation of spectra in qualitative terms very difficult. This is in contrast to the classical mid-infrared, where considerable interpretation is done with the use of large, library reference collections. At the present time, the library of spectra in near-infrared is just beginning. The fact that scattering is higher in the near-infrared than in the mid-infrared may appear to be a disadvantage, but it could also be used as an advantage. The near-infrared absorption is produced because of a second overtone, third overtone, etc. of the fundamental vibrations that occur in the mid-infrared. It has been pointed out that each successive harmonic is much, much weaker in intensity than the previous harmonic or the fundamental. The same statement is true with regard to combinations of fundamentals or combinations of overtones with fundamentals or with each other. The whole area of the near-infrared is characterized by weak absorptions. This has been thought of by many as being a good reason not to bother making measurements in this region of the spectrum.

We see, however, that this weak absorption characteristic actually can help to simplify, in a practical way, the spectra observed in this region. If a fundamental vibration in the mid-infrared occurs at 15 micrometers, its first overtone is at 7.5, its second is at 5, its third is at 3.75, its fourth is at 3, and only its 5th gets into the near-infrared region. By the time the 5th overtone is

Page 175: Instrumental

158

reached, there is practically no intensity left. This effect is beneficial. In the chemical sense, it can be stated that in the near-infrared the observable bands contain only light atoms and have strong molecular bonds. Typically in near-infrared, one observes strong bonds involving hydrogen. If the chemical bond is weak, then vibrational frequency is low, and overtones of that vibration never appear in the near-infrared. If the atom is heavy, the frequency is low, and overtones will never appear in the near-infrared. If one had to choose groupings to observe that are pretty much represented among organic compounds, one could not make a better choice than CH, NH, and OH.

One of the practical virtues of the near-infrared region is that the intensity of bands is not very temperature dependent. An exception to this rule of thumb is a situation where a chemical equilibrium that is temperature dependent can produce a change in the absorbing species. Water of hydration, for example, could have an equilibrium shift with temperature, so the spectrum also could change from one temperature to another. For this reason, to get good quantitation in certain cases, some degree of temperature control is required.

Now let us look at other virtues. In working in the near-infrared region of the spectrum, there is good news instrumentally. For a source to illuminate the sample, a quartz tungsten halogen lamp could be used. This is a very simple device and an excellent source having a typical emissitivity that approaches black body radiation. For a detector, lead sulfide may be used. Lead sulfide is well characterized, fairly rugged, and involves no particular problems (other detectors with a rapid response are discussed in the instrumentation section). The use of glass for cells or lenses is very convenient in comparison to using alkali halide salts. Excellent instrument performance can be achieved. In fact, the success of modem near-infrared analysis is very much dependent on making decisions based on tens of milliabsorbance units, thus, a noise requirement of a few microabsorbance units is standard.

The fact that the spectrum is rich with bands in the near-infrared means that conceivably a band can be found for almost anything. Furthermore, not only is that band found once, but the vibration of that band is repeated several times from one part of the near-infrared spectrum to the other and at different intensities. If a sample goes opaque at one part of the spectrum, the quantitative measurement simply can be shifted from the second overtone down to the third or fourth by going to shorter and shorter wavelengths. If the water band at 1900 nm is too strong because the sample is 60 % water, then the water band at 1400 nm, which is 10 times weaker, can be used. If necessary, the water band at 1100 nm, which is 100 times weaker, can be used. Thus, we can choose the intensity by choosing the overtone and going to higher or lower overtones, depending on whether the absorption is too strong or too weak.

Weak Is Better The very characteristic that makes near-infrared useful is that the absorption bands are

weak. This weakness of band intensity is, in fact, a virtue -- a very large virtue. In the

Page 176: Instrumental

159

mid-infrared, absorption spectrometry must be done with layers that are very thin, for example, slices 10 - 30 microns thick. A considerable amount of work has been done telling how to run samples in the mid-infrared. It is not particularly convenient. In the near-infrared region of the spectrum, intensities are 10 to 100 times less, so to compensate, samples are 0.1 to 1 mm thick, which is much more convenient. In certain cases, even greater thicknesses may be used. In fact, the lowering in intensity is all compensated for by the change in thickness, and at the same time, the system is instrumentally and experimentally more convenient.

Achieving quantitation additivity is necessary, so that the sum of the Absorbances of two or more overlapping bands will equal the total Absorbance at that point in the spectrum. Additivity requires reasonable linearity. It should also be pointed out that variations in the index of refraction produce anomalous dispersion. The contribution of anomalous dispersion is linearly proportional to the strength of the absorption band. The absorption can be controlled and made stronger by putting in more of the sample or making the layer thicker. In the near-infrared, because of the weak absorption, the issue of anomalous dispersion is sidestepped for all practical purposes. This is not the case in the mid-infrared. In summary, it can be stated that because the bands are intrinsically weaker in the near-infrared, no big variations occur in the refractive index. Therefore, there is not a large superimposed variation of reflection on top of the absorption that one is trying to measure. This simplifies the mathematics tremendously.

The near-infrared has still other virtues. If a sample is not homogeneous, as the case may be in a slurry or in a powder, local variation can be dealt with normally by taking a large area. Experimentally, we hope that by taking a large enough area of the sample the local variations will average out and the average property of the sample will be measured. It is impossible to do this, if any part of the sample is opaque. This refers specifically to the case of powders measured in the diffuse reflectance mode. Because of the intrinsically weak absorptions in the near-infrared, complete opacity is not achieved; thus, the light can make numerous bounces back and forth off the various different particles to produce an averaging for the non-homogeneity.

The broad bands often encountered in near-infrared may appear to be rather dull and uninteresting and certainly not aesthetically pleasing to the eye when looking at the plot of a spectrum. In the near-infrared, high resolution is usually not necessary. A few sharp bands exist where resolution for qualitative purposes may be advantageous. This occurs for spectra of simple chemicals but broad band features are predominant in the spectra of foods and commodities. For quantitative purposes, it is more important to reproduce the wavelength and have it a little broader than having ultimate resolution. In making quantitative measurements, there is an advantage to not requiring such a narrow band. Whether using a grating monochromator or using a filter instrument, as the band pass becomes narrower and narrower, the total amount of energy coming through becomes less and less. What is important is the percentage of the light allowed by the bandpass that may be affected by the concentration of the analyte. Since the analyte bands are

Page 177: Instrumental

160

broad, it is possible to have a relatively large bandpass and still provide good sensitivity to change in concentration of the analyte. This spectral feature of the near-infrared is another advantage that makes the job easier instrumentally and allows us to achieve the high signal-to-noise ratio required.

In the near-infrared, specifically in the diffuse reflectance mode, quantitative measurements of absorbance can be obtained where the scattering is very strong and the absorption is very weak. If, on the other hand, the absorption is strong compared to the scattering, then the reflectance becomes a nonlinear function of the sample concentration. If in the same mixture, another substance has an absorption at that same wavelength, then the problem is compounded. Non- linearity makes additivity impossible. In the near-infrared region, this is not a problem, because scattering is vastly more intense than in the mid-infrared and absorption is vastly weaker. Thus, all of the advantages of the near-infrared, particularly when it is applied to diffuse reflectance or diffuse transmittance, actually stem from its apparent weakness.

Additivity is the central core for the assumption of near-infrared quantitation because we do not have the luxury of samples containing one chemical analyte producing an isolated band for which a simple one-term Beers law expression can be used. Modern near-infrared work involves trying to determine multiple components. Numerous contributors to the absorbance at that band can exist at any given wavelength. The object is to single out the effect of one of those contributors. This can be done mathematically, but it can be achieved if, and only if, the absorptions or the signals from the different components of the mixture are combined with each other correctly, so the accumulated background may be subtracted quantitatively. In order for additivity to be achieved that allows quantitation from the mixture of absorbers, a measurement situation is required in which there is no anomalous dispersion, no resolution error, no nonlinearity, and no specular error. It is fortuitous that the absence of all of these experimental features, which if present could wipe out additivity, exclusively occurs in the near-infrared.

DEVELOPING A QUANTITATIVE NEAR-IR METHOD Near-IR spectroscopic analysis is dependent on development of an empirical linear equation

in which the concentration of the analyte is related to optical measurements, usually expressed as absorbance or, in the case of reflectance measurements, log 1/reflectance. To gain experience in this empirical approach, the analyst must have a set of samples for which known values have been obtained by another method. From this set of knowns, a learning process takes place. From this learning set, with sufficient experimentation and statistical treatment of optical data, a final calibration results. This is a multiterm linear expression with appropriate coefficients that makes appropriate analytical use of optical data. Table III shows some of the options by which calibration samples and the final optical wavelength for the analytical equation are obtained.

Page 178: Instrumental

161

Table m . Sample Selection and Wavelength Selection

Sample Selection Considerations Range of the Analyte Distribution throughout the Range of the Analyte, Range of the Secondary Analyte, Range in Variation in the Background Matrix Sample Selection from Optical Data without a Priori Analytical Knowledge, Selection of Samples for Verification

Wavelength Search Teclmiques Visualization

Log 1/R Plotted vs. Wavelength (Spectrum). Compare spectra known to represent extremes of the samples for consideration and look for differences between these spectra. Key on those wavelengths where differences are apparent.

First Difference Plot Second Difference Plot

Regression Visualization via Simple Linear Regression (one optical term at a time)

Log 1/R Correlation Plot First Difference Correlation Plot Second Difference Correlation Plot

Multiple Linear Regression Step-Up (Where to Stop?) Reverse Stepwise (Where to Stop?) Combinations (How to Choose from Equally Good Combinations?)

Selecting a Data Base Choosing samples for a learning set in correlation spectroscopy is the important first step

toward developing a near infrared (chemometric) analytical method. The final objective is to produce an empirical analytical equation including terms for selecting wavelengths that will be "robust" upon future application to all anticipated quantitative tasks for the analyte of interest in the matrix of practical consideration. Consider the case where you have a manufacturing production run of a particular polymer, and you need to know the average molecular weight, the amount of cross linkage, the thickness of the stock, and the presence of voids in the stock. In addition to the polymeric product, there may be some low molecular weight materials, spent polymerization agent, antioxidant, or additives present, as well as inert fillers (particulates of glass, graphite, or titanium dioxide). Faced with all of the above variables, you must decide if a preliminary division of sample types can be made on the basis of different formulation specifica- tions. The scattering characteristics of particles imposes a variable that must be dealt with in any attempt to quantitate the desired information (molecular weight, thickness, etc.). You may have to first try to limit a particular learning set to those samples with only one of the finer formulations.

Page 179: Instrumental

162

This, in turn, could be limited further to either high or low quantities of additives. (During the regression, the presumed subsets, high or low, are flagged by the use of an extra term in the multiple linear regression. That term indicates to which of two subsets each sample belongs. Regression results will show if the presumed subset selection is real and indicate any bias.)

After considering the variables involved, you need to assemble a collection of samples in which 1) the range of the primary analyte is broad, 2) the population distribution throughout the range is fairly even, 3) the secondary analyte, or at least the secondary component, also has a reasonably wide range, 4) the chemical matrix variables are represented in an appropriate distribution, and 5) the physical matrix variables are represented in range and in an appropriate distribution.

In order to get a good calibration, the range must not be too narrow. Good manufacturing produces uniform samples and a narrow range. Also, a narrow range produces a poor calibration. You may need to deliberately broaden the range by scheduling a special limited production run. The alternative is to accumulate all of the odd lots from production over an extended period of time. If absolutely necessary, spiked samples might be used to expand the range. Refer to Table III regarding sample selection and wavelength selection.

A good deal of laboratory analyses by conventional means usually are needed to select a calibration subset from a group of samples accumulated from routine production. Having accurate reference data on the learning set is essential. The precision (usually decided by blind duplicate determination) of the reference data serves as the performance target for correlation-based (chemometric) near infrared analysis methods.

This precision (standard error of difference) between duplicates is calculated by Standard Error = ,/E(Dif)2/(2n). Selection of a subset of samples suitable in range and distribution for one of the constituents (analytes) does not guarantee an equally well distributed broad range for the other analytes of interest, constituents 2, 3, etc. Typically, you choose the subset with respect to the primary analyte and incorporate a reasonable matrix variability in hopes that the second and third analyte distributions are adequate. The original subset used for constituent 1 should at least be inspected to see if additional samples should be added to extend the range with respect to constituent 2, or if samples should be selectively deleted to balance distribution with respect to that analyte before regression to obtain its calibration. Sample selection for most of the calibrations of the past few years has been done in this way. A common mistake among novices in correlation-based methods, such as near infrared analysis, is to use a brute force approach and assume that they have a collection of 100 samples available, all of these samples without regard to the analyte distribution should be included in the learning set. This presents a problem, because if a Gaussian distribution occurs along the analyte range in frequency of occurrence, then results in future analyses will be excellent only if the middle portion of the range is used. The levering effect of a few samples at either end of the range is counteracted by the huge mass of samples at

Page 180: Instrumental

163

the center. The hazard is that, when analyzing Table IV. Relative Weights of 19 Samples samples that are either higher or lower than the mean by a significant amount, the regression line produced will be weak with respect to samples at either extreme. Other patterns in disproportion of the distribution of samples throughout the analyte range could cause similar difficulties. You can readily realize that in order to develop a method, you have to have laboratory facilities or a good analytical budget to support the method development, because many reference analyses are required, usually in duplicate, to establish the expected precision.

19 Samples Selected: Relative Weight:

45.00 0.635811 7.00 -0.012880

39.00 -0.012814 2.00 0.008733 4.00 -0.003472

34.00 0.003335 18.00 -0.002018 43.00 -0.873392E-03 40.00 0.927747E-03 20.00 0.795698E-03 21.00 -0.657216E-03 13.00 -0.697789E-03 11.00 0.611978E-03 44.00 -0.580781E-03

6.00 -0.418739E-03 16.00 -0.347178E-03 15.00 -0.252797E-03 12.00 0.194112E-03 22.00 0.148186E-03

Much has been said about representing all anticipated variables of the future within the learning set, so that they can be handled statistically. The coefficients as well as the wavelengths chosen can minimize problems associated with the variations. Another way to ensure that all the variables are incorporated is to select samples based on optical orthogonallity. To accomplish this, spectroscopic data are obtained on a large set of samples first (prior to obtaining lab reference data), and a suitable program is used to select the samples in descending order of orthogonality. Software can be used for a calibration involving row reduction applied to spectroscopic data, which will order members of the set in decreasing orthogonality with respect to the preceding members of the set. Table IV shows the ordered relative weight of 19 samples. The result is that maximum optically observable differences are reflected in the set. Since this is done without any prior knowledge of analyte composition by a reference method, it is independent of the variability of just one constituent and actually reflects the total variability of both the matrix and the principal analyte, secondary analyte, tertiary analyte, etc. The theory here is that nearly all of the optical variables that your analysis instrument will see is accounted for in the regression model (i.e. training set). Then other members of the set will have some representation within the optical array of the training set at least within that population. This approach is particularly advantageous if a limited number of samples is available. It can save considerable time and money in analytical expenses, and it provides a guidance mechanism that has a greater probability of producing a more robust calibration than would be obtained merely by chance.

SELECTING APPROPRIATE TERMS FOR THE ANALYTICAL EQUATION

Wavelength Selection v

Visualization of wavelengths due to a particular analyte is the usual way that spectroscopic terms are found. If the absorbing species is known and its wavelength of maximum absorbance

Page 181: Instrumental

164

is well established, then the task is quite simple. If we then add, in the analytical wavelength vicinity, absorption of some matrix material and then superimpose some noise on the spectrum, the visualization technique produces results that are less obvious and, in fact, could be slightly misleading. The time-tested technique of plotting the spectrum of a sample that is high with respect to the analyte of interest and comparing it to a spectrum that is low in the same material is used to look for changes in absorbance related to that difference.

In most absorption spectroscopic methods, we anticipate a change that is readily observable in a plot. However, in near infrared absorption techniques, we are dealing with changes of just a few milliabsorbance units rather than tenths of an absorbance unit, as might be expected when working in other regions of the spectrum. Literally, the changes that one should observe may actually be obscured within the width of the pen used to plot the spectrum. Therefore, we need to examine digital data to see actual differences. This, of course, is somewhat tedious. Unlike classical absorption spectroscopy performed in dilute solutions, when dealing with solids or dealing with mixtures of liquids all of which have a prominent absorption spectrum, we have a closed, highly interdependent system, which in no way resembles infinite dilution (one of the requirements of applying Beer's Law). For example, with a highly interdependent system, if we consider a three-component mixture in which one component is constant, then when the second component decreases, the third component must increase. Thus, merely comparing digital readings at the wavelength of maximum absorbance of the species to be measured (the analyte) is dangerous, because the baseline is floating when concentrated liquids or solids are scanned. Actually, since in such a closed system, a direct relationship occurs with an optical term and an inverse relationship occurs with a different optical term, they are typically both used but with opposite signs on their corresponding coefficients.

For spectra where the change in absorbance, or log l/R, is small as a function of wavelength, i.e., where there are broad peaks rather than well defined, sharp peaks, it is sometimes useful to have a derivative plot (actually a first difference plot) vs. wavelength. Thus, we look for a slope at any point of the spectrum. Similarly, a second difference can be plotted; in the case of three points along the spectrum, we correct the center point to a baseline drawn between adjacent points on either side and plot the difference of the center point from the baseline vs. wavelength. This commonly has been referred to as a second derivative. It is in actuality very similar to the classical baseline method.

Visualization techniques may or may not be useful in identifying the primary wavelengths for developing correlation equations. Since this is an empirical technique, the statistical technique of regression also is used. In the simplest form, a simple linear regression is performed one wavelength at a time vs. the concentration of the analyte. Obviously, this requires a whole learning set of pre-analyzed samples with spectroscopic data for each member of the set. The correlation, positive or negative with respect to the analyte variation at any wavelength, is plotted. The series

Page 182: Instrumental

165

of these then produces a correlation spectrum. Simple regression (one term at a time) also may be performed on first differences or second differences spectra. In the correlation spectrum, positive peaks indicating a high positive correlation in excess of 0.9 or, alternately, a high negative correlation in excess of 0.9, would point out good candidates for a first try in a multiple linear regression equation.

S.tgl2r._U_~ From the simple linear regression, we then could choose the one wavelength that has the highest correlation with the analyte. We then could add another wavelength to the first wavelength to get a pair of wavelengths for a multiple linear regression with two variables and subsequently from the remaining members of the set choose a third wavelength, a fourth, etc. As additional optical data are added to the expression, we would anticipate that the correlation coefficient should increase, that the standard error of calibration (SEC) should decrease, and that other statistical indicators should change also. Refer to Table V where steps in a typical calibration process are outlined. In the step-up, multiple linear regression, when an improvement in the statistical indicators does not accompany an additional incorporation of another term into the expression, then the step-up procedure is stopped. A step-up procedure is useful when many, many wavelengths are available.

Reverse Stepwise. When a somewhat limited number of wavelengths exist, such as 25 or 30, and if we have the computational capability, we can start with all wavelengths in the expression and then after the regression is performed, use a statistical term such as the student t-test for each individual wavelength term, discard the one that has the t-test closest to zero, and perform the regression all over again with one less datum. This procedure is repeated again and again, and after each step, we examine the correlation coefficient, which may decrease slightly, and also the standard error of calibration, which may increase slightly. If available, we also observe the F of regression, which may change as the elimination procedure goes on. A drastic increase in the standard error of calibration typically indicates that one too many variables have been removed. Therefore, we can back up to the previous equation which probably would give us the right number of wavelengths in the expression.

Coml~ination. A powerful multiple linear regression technique is used to identify the set of wavelengths by combination rather than by step-up or reverse-stepwise procedure. In the case of starting with 19 different wavelengths, if we choose a combination of three from a field of 19, there are 969 different combinations that have to be tried. With modern computational power, an all-possible-combinations search is realistic. In this type of procedure, a statistical indicator such as the F of regression can be used to determine which combinations are saved and which are discarded. One program of this type chooses five sets of three that give the best statistical value. Combinations of four or five may be considerably more valuable, but the dividends do not always justify the extra computational time.

Page 183: Instrumental

166

Table V. Successive Steps in Calibration and Validation Criteria of Successful Regression Results

Correlation Coefficient (It should be large) Standard Error of Estimate (Calibration) - should approach lab error t-Test for Individual Wavelength Terms (look for large positive or negative) F of Regression (look for large value) Comparison of Standard Error to Analyte Range

Equation Selection Minimum Number of Terms (terms with no information still contribute noise)

Indicator Wavelengths Should Make Sense Spectroscopically Reference Wavelengths Should Be Included Consider Wavelengths That Should Be Included Based on Chemical Information

Testing of the Equation for Performance Terms for Judging Performance SEP (Standard Error of Performance - This is distinguished from the Standard Error of Calibration in that all members of the validation set are ordinarily not part of the original regression database. Validation Sample Selection Cross Validation when Samples are Limited - Tests for robusmess of the calibration

Global Methods (applicable to scanning data) Principal Component Regression (PCR) Partial Least Squares (PLS) Neural Networks

Establishin~ the Calibration - v

Multiple wavelengths chosen by a multiple linear regression procedure should not necessarily be accepted without a careful look. If several sets of different wavelengths give approximately the same statistical results for a given set of data, we can choose to exclude a set, for example, incorporating a moisture wavelength, if we want to avoid keying on differences in moisture. Thus, even though this is an empirical technique, a little spectroscopic sense is certainly valuable. "Don't let the computer do your thinking for you." When considering the criteria of successful regressions, a correlation coefficient in excess of 0.9, preferably approaching 0.999, certainly is useful. However, the F of regression or standard error of calibration is perhaps of greater value in judging success. The standard error of calibration (SEC) indicates the standard error of difference between calculating the analyte value from the empirical equation produced

and the analyte true value from some reference method. The object is to have the standard error of calibration approach as near as possible to the

standard error of difference of blind duplicates done by the reference method. We also should compare the standard error of calibration to the analyte range. A standard error of 0.2 percent

Page 184: Instrumental

167

may be very small over an analyte range of 10 percent, but would be considered very large over an analyte range of 1 percent. When trying to determine initial feasibility of the technique, we often artificially expand the range. When doing this, an error representing 5 percent of the range would indicate a useful method. However upon application of the method, if the range is perhaps only half as great as that used in the feasibility study, then the relative error within the range is much larger.

Selecting the analytical equation depends first on having a good learning set from which the wavelengths are chosen carefully and from which good coefficients will be produced. To be successful analytically, the equation must be robust, i.e., it must be applied successfully to future samples. To try to accomplish this, any variables that we anticipate ever seeing in the future, if possible, should be incorporated into the original database. The use of unnecessary terms should be avoided. If an equation with an adequate correlation coefficient and a reasonably low standard error of calibration can be obtained with two or three wavelengths, there is little reason to use 17 or 18. A greater number of terms in the expression undoubtedly will produce a higher correlation coefficient and a somewhat smaller standard error of calibration, but upon applying this equation to future samples that were not in the original database, we may expect an equation less robust than one with a minimum number of terms. The hazard is one of overfitting.

For a spectroscopist, the wavelengths chosen should make sense, whenever possible. Typically, a wavelength representing an absorption maximum for the analyte would be incorpo- rated into the expression, and it would be accompanied by a positive coefficient and would show a highly positive t-test for that particular term. In a limited system, when the quantity of one of the materials in the concentrate decreases, the other one increases. In such a case, it is possible, also, at the wavelength of maximum absorbance of the secondary material in a mixture, to have a highly negative correlation, to use a negative coefficient for that term, and to have a negative t-test.

Furthermore, in the case of granular solids in which considerable light scattering occurs, or in the case of diffusely transmitting liquids or solids, some nonindicating wavelengths or neutral wavelengths are needed to allow some normalization to the scatter effect that shifts the baseline. Any equation chosen should be examined with respect to spectroscopic intelligence and also examined, in some cases, to deliberately exclude certain wavelengths, which might tend to bring into play the variability of a component that should be ignored so the calibration will not be dependent upon it.

When using derivative techniques, the multiple linear regression methods, listed in Table VI, may be similar to those discussed under step-up or step-down. However, each term in the expression is actually a composite of two terms in the case of a first difference, or three terms, in the case of a second difference. If one of the terms incorporates a ratio of first differences, then actually four optical readings are required to produce the ratio of first differences. Similarly,

Page 185: Instrumental

168

Table Vl. Typical Computational Algorithms

(a) % = Z + a log l/R1 + b log 1/R2 + c log 1/R3 + ...

(b) % = Z + a(log R2- log R1) + b(log R4- log R3) + ... (first difference)

a ratio of second differences re- quires six optical readings to be incorporated in the one ratio that appears in the final equation. Thus, a three-term equation in- volving three second-derivative

( logR2-1ogR~) ( l o g R 6 - 1 0 g R 5 ] + . . ratios actually would require (c)% = Z + a logR4 log +b logR8 logR7/ "

measurement at 18 separate (pair: ratio first differences)

(d) % = Z + a(2 log R2- log R1 - log R3) + b(2 log R5 - log R4- log R6) + ...

(second difference)

(2log R2- log R1-log R3 ) (e) % = Z + a log R5 log R4 log R6 +

/ ' 2 log R8- log R7 - log R9 ) b~21ogRl l logR10 logR12 g

(trio: ratio of second differences)

wavelengths. One important variable, which is part of the calibration when the difference equations are used, is the incre- ment between adjacent wave- lengths. This has been referred to as the "gap." Some elaborate schemes actually will vary the gap of difference and optimize

Note that RI, R2, R3, R4 . . . . Rn represent reflectance in order for that. In some cases, a differ- by wavelength (Ref. 6). ent increment will be used in the numerator than in the denominator within the same ratio. On the other hand, certain operators habitually will use the increment of their choice in all the methods that they develop. Obviously then, the fine tuning of an analytical expression of this type is somewhat dependent on the choice of the operator.

Transferring calibrations is certainly of interest when you want to use a calibration produced by someone else or if you want to use the same calibration at several different locations within the same company, and the calibrations are maintained by someone at the central laboratory. Certain designs of instruments allow the possibility of matching the optical hardware so that calibration transfer can be done without a great deal of mathematical intervention. This obviously involves reproducing the transmission profile of interference filters used in the same model of the instrument. In general, the best way to transfer a calibration is to transfer not only the numbers from one instrument to another, but also the samples. Thus, a set of samples that have been measured on one instrument can be taken physically and run on a second instrument, and the differences in the analytical results for the very same samples can be measured. From this, departure from the regression slope established by the first instrument is referred to as a skew, and any offset is referred to as a bias. If the optical matching of all of the different filters involved in the calibration is good, little or no skew will occur. In such a case, the transferred calibration probably can be accomplished with just a change in the bias setting.

Page 186: Instrumental

169

In the case of solid samples for which the diffuse reflectance technique is used, an even finer match can be made by grinding two portions of each sample. In this way, a grinder and an instrument at one location would involve a specific sample preparation and specific optical readings on the individual samples. When the other portion of a divided sample is ground at a second location with its local grinder, optical measurements then are performed on the second instrument. By pairing each instrument with its grinder, even better calibration transfer and matching can be accomplished.

Global Techniaues Spectral data from scanning instruments may be treated as if they were discrete wavelengths

or with global techniques. Among global transforms, the three mentioned here include principal component analysis (PCA), partial least squares (PLS), and Fourier transform (FT). Global transform may be used for reduction of data (presumably without loss of information). With this process, there is no wavelength selection, no spectrochemical consideration, and a threshold setting or factor analysis is the result. Global calibrations utilize all wavelength information with no wavelength selection. The sequence of a typical global calibration is shown in the block diagram.

Original data set

transform. Fransform data set

reduction _~educed regression "[lata set

Calibration constants

.IPrediction -}values

The two global calibration methods mentioned here include principal component regression (PCR) partial least square regression (PLSR). Both of these start with a PC transform. The PC transform establishes the order of explaining variance in the data. The process involves orthogonal axes and the weights are expressed in eigenvectors. The first principal c o m p o ~ t accounts for perhaps more than 90% of the variance. Each successive principal component accounts for less than the previous one.

Independent of PCR, principal component analysis provides useful information. If the magnitude of the eigenvector of the first PC is constant for all wavelengths, then it is likely that there is a non-chemical cause of the variance described by that PC. If wavelength specificity is apparent from plotting the eigenvector of the second PC vs. wavelength, then a chemical source of variance is likely. The wavelength pattern revealed may be either positive or negative. If wavelengths of 1445 and 1940 nm have eigenvectors far removed from zero, it is likely that the chemical source of variance in the sample set is water. PC analysis is useful to find out if the wavelengths of interest from the chemistry of the analyte or those chosen by another calibration procedure, have eigenvectors that exceed the eigenvectors of the first, second, or other low principal component at those particular wavelengths of interest. The sources of variance that are

Page 187: Instrumental

170

E2 P1

o.~ El*

Direction of first largest

ce

\ Direction of second - N~argest variance

Fig. 23. Vectors of new variables P1 and P2.

independent of the analyte variance represent sample "noise" that must be exceeded by the "signal" from the absorption relative to the analyte.

The principal components that result from applying the transform to the data produces new variables P = CllE1 +C12E12 and P = C21E1 +C22E2. Weight selection produces the relation- shipsCll + C12 = 1 andC21 + C22 =1. Thevector representation is shown in Figure 23. The direction of the first (largest) variance is shown with the two highest magnitude opposed vector and the orthogonal lower magnitude opposed vector representing the direction of the second largest variance.

Regression of principal components pro- duced a calibration and the values predicted from near-IR analysis are compared to the lab values as with other methods previously discussed. Similarly, a validation set is used to determine SEP.

Partial least squares regression assumes measured variables X,Y = f(latent variable) + residuals. The PLS model attempts to describe the variance in the prediction set of data using "latent variables". These are analogous to principle components used in PCR techniques. The PLC latent variables are linear combinations of the prediction. PLS calculates the latent variables in the order of importance and only the number of latent variables that are useful in the model are retained.

The PLS algorithm involves iterative estimation of one term in the model by successively estimating another term. Calibration for analysis by PLS consists of three steps: 1)Determination of the optimum number of PLS factors to produce a useful model, 2)Use validation set determining the predicted residual error sum of squares (PRESS) to accomplish 1), and 3)Use the weight or loading spectrum for "chemical" information. Validation in this case is an integral step and discards unuseful latent variables in the process of establishing the model and calibration. PLS is considered to be a compromise between least square regression and principle component regression. In some instances, one of these global methods has produced a more robust model. One prominent practitioner of chemometrics for spectroscopic calibration suggests that in practice, one should set the goal for the needed or desired standard error of performance. Try the least complicated approach first. If that approach is within the goal, refine the expression, recheck the validation and go about the next task. More sophisticated calibration procedures may be tried as the next alternative.

Page 188: Instrumental

171

Data Pretreatmenl The most common form of data treatment of classical vibrational spectra is the division of

single beam measurement of the sample by the background (blank) data to produce a transmittance spectrum or alternately, a log 1/R or absorbance spectrum. Baseline correction may be used as an aid for visual comparison of overlaid spectra. When the data is noisy, Savitsky-Golay or other smoothing algorithms may be used. This may be done not only for cosmetic display purposes, but in fact prior to quantitative determination calculations.

Derivative spectra may be obtained (see 1st difference, 2nd difference, etc. examples in Table VI) as a form of compensation for baseline shifts particularly for scattering effects and as a bandsharpening procedure to bring out small changes in slope that occur in the Absorbance or log 1/R plot. As mentioned under the wavelength selection part of developing a method, the result of regressing the 1st or 2nd difference of each wavelength to produce a correlation plot vs. wavelength has been used for that purpose. For quantitative method development this may not be necessary. Baseline shift among members of a group of samples the same general type is routinely compensated for without any data pretreatment by allowing the multiple linear regression procedure to incorporate a single wavelength or a composited wavelength optical term into the analytical expression resulting from the calibration procedure.

One form of normalization used when one has a collection of spectra or data points from spectra to be compared is referred to as mean center and unit variance according to the steps:

1)Mean center by calculating the average absorbance and subtracting it from the spectrum 2)Establish a unit variance by dividing all absorbances by the standard deviation

The spectra that result from these operations are plotted above and below zero on the y axis that intersects any point coincident with the mean absorbance. Because all spectra being compared are plotted around zero, the bias has been removed. A high contrast in absorbance produces large standard deviation that results in a large divisor. A correspondingly low contrast spectrum by comparison is awarded a handicap by this operation so that the different contrasts produced for spectra with generally high absorbances are normalized to those of spectra collected at low absorbances. Another normalization process that is more statistical in its approach is the multiplicative scatter correction that involves the following steps:

1) Mean centering the spectrum 2) Curve fitting the spectrum to the average spectrum 3) Dividing the spectrum by the curve fit value Normalization data pretreatments are also useful under appropriate circumstances but not

in all cases. In many situations, the optics of the sample are such that there is nothing to be gained from normalizing the data. In still other cases, a loss of information may result because the plots all become relative and the absolute optically defined percent Transmittance is lost. Note that the effect of scattering that would automatically be revealed as a vertical offset effect, a difference in

Page 189: Instrumental

172

slope, and a difference in contrast between the Absorbance values at absorbing and non-absorbing wavelengths would be lost. Additionally, the presence of a large particulate population of a size smaller than the wavelengths being used would also be apparent from the spectra that are not normalized. In such a case the portion of the spectrum affected would be avoided for quantitative method development. Knowledge of these effects of scattering allows the analyst to consider the affect on quantitation. For sorting and identification purposes, the granulation may be an important item that is sought. Optical sieving is a practical way to measure uniformity or deviation from a mean expected particle size.

Qualitative (Discriminan0 Analysis from Quantitative Near-IR Data Qualitative determination is possible with quantitative near infrared data using a technique

described by statisticians as discriminant analysis. Objectively establishing the identity of a granular solid or liquid is often quite important in a manufacturing setting. Work in discriminant analysis using near infrared began in the pharmaceutical industry initially with discrete wavelength data (7). Chain of custody record keeping is important in the pharmaceutical industry. When a drum of material arrives from a supplier it is important to establish whether the powder present is what it is reported to be or whether it is some other substance. The same is true for liquids. Scanning the mid-infrared spectrum was used in the past, however, for ease of operation scanning the near infrared spectrum often with a fiber optic probe is a more convenient approach. Once this has been done, test data are compared with the spectroscopic data on record of established standards for the substances (from individual suppliers and the production facility where it is to be used). A statistically based, multiterm, pattern recognition procedure may be employed or a spectral matching process may be used. Some FT-NIR instruments equipped with probes were brought on the market specifically for the field of sample identification.

A discriminant analysis involves using a multidimensional function consisting of weighted combinations of discriminators. This function may incorporate the raw absorbance data at selected wavelengths. These wavelengths would have been chosen statistically in order of their value of discrimination capability. Similarly multiterm expressions can be constructed for discrimination where each term is a composite of several optically based factors. Such composited values could be based on principal components or another composited term such as a canonical variable. The number of terms used in discriminant analysis is determined by the calibration procedure that also generates appropriate weighting terms (coefficients).

To illustrate the use of multiterm discriminate functions let us consider one case in which the raw absorbance data is used. The Mahalanobis distance is expressed as a unit distance where the unit is one standard deviation (8,9). A training set is used where materials of types A, B, and C would be divided, and when the sample is run to collect optical data, the identity of A, B, or C is keyed in with the optical data. When data are collected at many wavelengths for a group of perhaps 20 specimens of each group, a consensus (cluster) of optical data values will be produced

Page 190: Instrumental

173

at each wavelength for each type of compound.

Thus, a locus in multidimensional space will be

established for the optical response typical of A

at each wavelength, and correspondingly differ-

ent values will occur for at least some of the v . -

wavelengths for compounds of type C and com-

pounds of type B. The quantitative difference in

these optical values is the basis of discrimination.

Among numerous near-IR data points a Maha-

lanobis distance discriminant analysis search pro-

cedure identified wavelengths in descending or-

der of their contributions as discriminators. In

the example cited between three dimensional CO

ellipsoids for groups A, B, and C, the Mahalano- r r

bis distances were: between A and B = 15,

between A and C = 27, and between B and C =

12. Raw optical data for the three top discrimi-

nating wavelengths are plotted in Figure 24

where the success of sorting three different prod-

ucts (A, B, C) from quantitative data at select

wavelengths is obvious for the example shown.

When the discriminant function is established,

the program is applied to unknown materials and ~, the Mahalanobis distances are calculated (for the

data of the new compound) from the centroid of

the multidimensional data of A and from the

centroid of the multidimensional data for B and

C. In the example cited, three optical terms are

used and it is easy to visualize an ellipsoidal three

dimensional graph. The mathematical process

could just as well handle may terms in hyper-

space. Each added term increases the size of the

cluster. Applications of the discriminant analysis

equation to unknown samples resulting in the

Mahalanobis distances (listed in Table VII) from

groups A, B, and C respectively. A low Maha-

lanobis distance indicates a potential hit (Note

underlined values). When the Mahalanobis dis-

�9 o �9

�9 �9

�9 �9

4

4

o � 9 oe0

1722 nm

�9 �9

O o o

�9 �9

O �9 �9

1722 nm

�9 �9

�9 �9 �9

�9 �9

o o

2348 nm Fig. 24. Log 1/R values for selected wavelengths.

Table VII. Mahalanobis Distances of Unknows from Each Group Shown by Closest Distances

Sample # Group A Group B Group C 7 1.05 14.9 26.8

34 27.6 12.9 2.39 18 15.1 2.04 12.5 8 1.54 15.6 27.3

33 26.2 11.5 2.02 17 15.7 0.737 11.3

Page 191: Instrumental

174

f : A N I -(., 'AN3

t t

/ 0 0 s s

- , , 0 r

" la' ~ 8 ~ 1 7 6 I �9 . 4 , s 0 0 0

-CAN2 O-" ---~_ "q~'./4 "e C'AI~'2

/ I �9 ee / . ; ,,~ �9 . , " o

/ " i r . �9 t . . . . . , �9 .

C A N 3

�9 -(:ANI

tance from the other components is high, that identity is excluded. When the Mahalanobis distance is beyond a certain distance from any of the group, then it is declared as being excluded from A, B, and C.

Composited optical data may be used also. One such form is that of canonical vari- ables (CV). CAN1 is a value calculated from a weighted combination of several optical terms (Absorbances). CAN2 employs the same wave- lengths and optical values but different coeffi- cients used describe a qualitative characteristic that is orthogonal to the preceding term. A series of CV's are produced but usually not all are

Fig. 25. Sorting of four groups based on 3 canonical required to perform the desired discriminant variables, analysis. The graph in Figure 25 shows excellent sorting of 4 groups in 3 dimensional space where each coordinate represents CAN1, CAN2, and CAN3. This method of qualitative identification based on quantitative data is very useful and it is an automatable approach. Not only is this technique used to perform qualitative analysis but this technique may be used to develop smart near infrared systems as an automatic sorting mechanism so that only the correct quantitative expression can be applied to a sample submitted for analysis and an incorrect result is avoided.

Another approach involves spectral matching of scanning data. Typically, when data is taken at many wavelength points, all points are processed in some type of spectral matching scheme. One of the original spectral matching schemes, previously used in other regions of the spectrum, was a comparison of the cosine at each point along the spectroscopic curve of an unknown with the cosine functions of the stored scan of the known reference spectrum. Another approach has been to establish a spectral library for particular materials that are involved and to collect the spectrum from samples presumed to have the same identity as a member of the collection in the library. The spectral data obtained from the test sample is then filtered mathematically by applying a mean center correction, normalization, and compensation for baseline tilt. Euclidian distances are calculated for each point in the spectrum and a statistical expression is used to test the match of the two spectra or eliminate the standard being compared. Small Euclidian distances indicate a probable hit. A large Euclidian distance eliminates the compared compound from further consideration.

Page 192: Instrumental

175

Strate~ for Succgssful Mgthod Development and Examples There is no substitute for knowledge of the chemical system at hand and control of the

information going into the calibration and minimization of the variables. There is no doubt that many a good near-infrared calibration has been performed by a statistician who was given laboratory and spectroscopic data and told to proceed using a prepared chemometric routine. In many cases the relationships have been obvious and a straightforward procedure has shown that relationship so clearly that any deviation from it was recognized immediately as incorrect. In other cases, however, a good calibration and developing a sound method have been very elusive. In many of those difficult cases, a relationship cannot be found either because none exist or it is severely obscure. After nearly three decades of encountering near-infrared applications and attempted applications, this chemist is nevertheless still surprised to find old problems at last being solved by a new strategy. Software can do only so much. For the most part, sophisticated treatments reduce the uncertainty in theoretical threshold represented by the 1st principle component or other contribution to variance greater than the variance caused by the analyte. As each veil is removed, the image (correlation) becomes more clear. The applications laboratories of several industrial, government, and instrument companies operate at the mercy of samples and laboratory reference data supplied by sources over which they have no control. Often they have little knowledge of the sample material itself and may not be fully aware of the significance of the laboratory data with reference to that material and the desired method.

In the field of correlation spectroscopy, which we encounter with chemometric methods, we are dealing with obvious relationships in which a large difference in strong absorption bands and subtle relationships occur. In these obvious relationships, uncertainties "noise" does not prevent revealing the relationship between the absorbance of a strong band and the presence of the grouping responsible for that strong band, even in the presence of a complex matrix material. Earlier successes resulted for easy-to-solve problems. These did not require a more comprehen- sive strategy to obtain successful method development. When dealing with more subtle optical differences, the subtlety of the chemical differences also may come into play. Under these circumstances, the chemist developing the method needs to maximize control of the situation and minimize the introduction of systematic biases and random items, which confuse the issue and obscure the subtle relationship that he or she is trying to discover. When dealing with these difficult problems involving subtleties performing an iterative sorting process may be necessary to eliminate the confusing issues.

Because OH absorptions are strong, any determination of moisture or polyols is expected to work. The production of any condensation polymer that results in elimination of terminal OH groups can be revealed readily at any stage of the process. For strong bands such as OH, the correlation of spectroscopic data with laboratory data is overwhelming, and the presence of bad numbers among lab data or spectroscopic data will not interfere with discovering the relationship.

Page 193: Instrumental

176

P R O T E I N F R A C T I O N S d~e

g .J

In the instrument business, it is well known that if you want to impress a potential customer with the reliability of an instrument, polyol data is used because it almost never fails. Such molecu- lar properties as unsaturation or the ratio of methyl to methylene groups are somewhat less obvious than those involving OH but nevertheless we expect them to work provided that the rela-

,.~ being used for calibration and method develop- ment.

"' 1.~8 ' '2:4

~r, An example of measurement of obvious Fig. 27. NIR starch and cellulose spectra showing and more subtle properties is found in a series of differences in carbohydrate bands, intermediate product flour milling streams.

These streams have wide variations in chemical content and physical and optical characteristics for quality control. Determination of non-endosperm is difficult because the signals are low and the multipliers high. This analysis cannot tolerate large differences in chemical matrix composition or scattering. It was done successfully only with custom calibrations for each test point stream for an on-line analyzer in the flour mill. Determination of protein reliably in different flour steams by near-IR required an iterative sorting process among more than 20 millstreams in the Kansas State University pilot flour mill. To successfully measure the NH near-infrared bands in the presence of all the other variations among the flour millstreams required a sorting process and a categorization of each type of material that would affect the background and require different calibration coefficients to produce a reliable protein analysis. This was a major task involving knowledge of the milling process, analysis of each stream for components other than those being analyzed on a routine basis; and an observation of the light scattering characteristics, which were dependent on the particle size that occurred in the natural production of these different mill streams.

' ' ,:, ' ~,'~ ' ' a:, ' - tionship that we seek is not obscured by the Fig. 26. NIR soybean and wheat spectra showing presence of too many other materials in the differences in protein bands, sample matrix. When dealing with mixtures of

C A R B O H Y D R A T E F R A C T I O N S . v proteins from multiple sources, such as soy pro- ~oI / / �9 ~o, ~ ~ / / tein in the presence of wheat protein (Figure 26),

s t a r c . . ~ i 421~. 4 + ~ - " ~ . . . . . . . |0~IA c/q+, . . . . ~ I the relationship is more subtle, because the dif-

0.6. r / ' ~ ] "~" / ~,,., -~"" c~, . ~,, . . / / ~ ferences may be small. Also, when looking for /o . , .~ , : ~ ~ / \ a small amount of cellulosic polysaccharide in the

~ presence of starch (Figure 27) the subtleties / A $ ~ h

4

o ~o,I.,o.. require minimizing the variables in the strategy O.=

Page 194: Instrumental

177

Various spectroscopic and statistical sorting techniques produced five different groupings. For the purpose of protein analysis it was ultimately possible to merge these individual groups into two major groups and one minor group. Advanced information concerning the milling process itself did not provide the proper sorting nor did optical data related to light scattering or particle size alone serve this purpose. Trial and error grouping and regrouping were needed.

In contrast to the major challenge of protein calibration that required data collected over multiple sessions of pilot mill operations, the moisture calibration was less complicated. For the protein determination, it was necessary to reduce the magnitude of the major contributor to variance. The different moisture calibrations produced from the same five groups were evaluated separately. After doing so, unlike the protein which required three groupings, all five subgroups of milling streams could be merged into one overall moisture calibration, which did not suffer by introducing an unacceptable standard error of performance.

Determining moisture in processed meat is economically useful because once a certain stage of the processing is reached, by law the moisture level can not be altered. In this case, success was achieved only by carefully controlling the time of sample weighing for reference data and optical measurement to within less than one hour of each other. Similarly, simultaneous NIR and reference data sample handling timing was critical for calibrating moisture in flour dough because the water extracted in anhydrous methanol prior to GC determination to obtain reference data was reduced by fermentation in only a few minutes.

When trying to establish a near-IR spectroscopic relationship based on some "function- ality" rather than the actual chemical content of the material, we need to ask the question of what property could be measured to reveal the spectroscopic relationship to functionality characteristics rather than trying to work with a traditional causal chemical structural feature having a less meaningful effect. One important specification in the buying and selling of fats and oils is the solid fat index. The percent of material that is solid is determined at several different preestablished temperatures. This requires a time consuming process. Regression of the properties at several temperatures versus near infrared data is impractical. Regression of the percent solid at one temperature may or may not be of value. Chemical consideration of what causes an oil to solidify and become a fat is focused on two chemical characteristics.

One is the number of double bonds present in the fatty acids that make up the lipid. This property is typically described by the iodine value that originally was based on titration of the double bonds by the disappearance of iodine by an addition reaction. In the modem era, iodine value often is determined by gas chromatographic analysis of fatty acid methyl esters, and these data are convened to iodine values. Iodine values determined for the calibration set were used to establish the appropriate wavelengths and calibration coefficients to obtain this property directly. Measurement of unsaturation alone did not solve the property described by solid fat index. Solid fat index is dependent also on the molecular weight, and therefore, high performance liquid

Page 195: Instrumental

178

chromatographic (HPLC) data were obtained on the calibration set to produce a mean carbon number. This contrived reference data incorporated both carbon chain length of the fatty acids and unsaturation. From chromatograms of the fats and oils used for the calibration, the relative contributions of C12, C14, C16, and C18 fatty acid chains were determined. With reverse phase HPLC, fatty acids with two double bonds contributed to the population of the chromatographic peak of a single double-bond compound with two less carbons, e.g., the peak area of C 14:1 would be enhanced by C16:2 and C18:3. Thus, the mean carbon number determined on fats and oils by reverse phase HPLC in fact did incorporate two causes of either liquidity or solid formation. A high population of the C 16 and C 14 chromatographic peaks would most assuredly predict a liquid at room temperature. This would be true either because there were in fact several C 14 fatty acids, or there were C16 fatty acids with two double bonds, or C 18 fatty acids with three double bonds. Either of these three types of fatty acids would contribute to the liquid state of the lipid. The result was that the quality (functionality) of a food ingredient could be practically characterized from near-IR data rather than the traditional time-consuming solid fat index that required multiple values to produce a profile.

SOLVING ANALYTICAL PROBLEMS IN FOOD, BEVERAGE, AND AGRICULTURE: EXAMPLES AND CONSIDERATIONS FOR SUCCESS

Take command of the situation; know your samples; seek information concerning morphology; learn of expected variability from all sources that will affect your samples; be responsible for reference data (preferably perform difficult procedures in your own lab); be aware of the precision of the reference method; consider the measurements required to produce reference data and ask yourself if there should be a molecular link between the property represented by the lab reference data and a spectroscopic observation; be responsible for sample procurement and handling; know the origin, history, and care or treatment of each sample; be prepared to exclude samples or data that confuse the discovery process or obscure the relationship being sought. In summary, filter the data, filter the samples, try to find the relationship in the absence of these confusing factors. This strategy cannot be put into a computer program. Various statistical tools will reveal an outlier. In practical terms casting out outliers may be fatal because the calibration produced will work very well on samples in the middle range (when you do not really need it) but will fail miserably to analyze those samples that are outside the middle range when the analytical technique is needed the most.

One food and agriculture laboratory known to the author where the best possible combination of resources is available is at the Quality Assessment Research Unit of the Russell Research Center U.S. Department of Agriculture in Athens, Georgia. Table VIII shows a list of particularly challenging food and agriculture related near-IR spectroscopic calibration triumphs. Easy problems have been solved previously. Some of the calibration successes listed in the table

Page 196: Instrumental

179

Table VIII. Project Areas of the Qualitative Assessment Research Unit Involving Near-IR

Problem Spectral Re#on Reference Method and Comments

1. Dietary Fiber NIR 1100-2500 nm AOAC enzymatic assay, key was and 850-1700 nm minimizing error in reference method

2. Temperature to which poultry had been chilled

NIR 1100-2500 nm thermocouple and controlled storage

3. Premature browning NIR 400-2500 nm color and enzyme level

4. Flax Quality NIR 1100-2500 nm subjective, scale created on residual aliphatic CH Raman, py-GC-MS

5. Rice Flavor and Texture NIR 850-2500 nm sensory panel flavor and texture

6. Rice composition and quality 850-2500 nm (full and standard reference methods and new reduced data sets) ones developed for amylose/amy-

lopectin, NMR, py-GC-MS

7. End use quality for wheat 400-1100 nm determine composition and milling and baking quality on whole grain involves use of NIR, FTIR, Raman and NMR

8. Grain moisture online sensing

NIR 400-2500 nm and ability to measure moisture content 10-33 GHz and sense blended lots

9. Interpretation of NIR spectrum

NIR, Raman, FT-IR, use of 2D correlation spectroscopy to NMR let one region help interpret the other

10. Multi-region models Raman and NIR small slices of more than one spectral region in model

*Franklin E. Barton II (Phys. Org. Chem.), David S. Himmilsbach (Phys. Org. Chem.), Danny E. Akin (Biologist, Microscopis0, Douglas D. Archibald (Anal. Chem., Chemomatrician), Sandra Kays (Anal. Chem.)

Page 197: Instrumental

180

are used for regulation and commerce, some for labeling, and some in breeding programs to predict quality. Use of near-IR wheat protein screening of early generation breeder samples at the Kansas State Agricultural Experiment Station by the author enabled the breeders to raise the wheat protein level by 2.5 % absolute in 10 years. One achievement, cited in Table VIII that particularly caught the attention of many of us who deal with food analysis is the USDA near-IR dietary fiber work. This method has been much needed for a long time and many other teams of researchers who have attempted this, obtained unsatisfactory results and gave up. Persistence, diligence and strategy has prevailed. What is particularly advantageous about the team approach taken at this facility is that not only is near-infrared instrumentation available and persons to operate that equipment, but at this site there is also the capability of obtaining mid-infrared spectra, Raman spectra, and NMR data on various materials under the supervision of professional classical spectroscopists and physical organic chemists. Wet methods and improved automated procedures for obtaining reference data such as that required for dietary fiber are also available at this facility. The precision and accuracy of reference methods are under constant scrutiny and when necessary, improvements are made to tighten up procedures and reduce uncertainty ("noise") in the reference data. The involvement of a biologist, who is a world class microscopist, is available at this location and a research model microspectrometer with ultraviolet and fluorescence capability is available for looking at morphological detail. FT-IR and Raman microspectrometers compliment the data obtained by other means and the spatial resolution achievable makes it possible to look at a whole section of material from the microscope field and obtain the spectrum of only the subsample of interest. Last, but not least, are the services and valuable contribution of a highly experienced chemomatrician. Examination of the list of achievements, most of them from relatively recent efforts, shows the progress that can be made when a team approach is used.

INSTRUMENTATION FOR NEAR-IR SPECTROSCOPY Perhaps 80% of the near-IR analyzers in use are interference filter instruments equipped

with a quartz tungsten halogen source and a PbS detector that requires a phase sensitive amplifier and has a digital readout. Among filter instruments, the method of mechanical filter changing differs as does the scheme for referencing at each filter wavelength to a blank transmittance or reflectance standard. The detector optical geometry also varies with the instrument and depends somewhat on the nature of the sample. For solid sampling where diffuse reflectance is used, the location of the detector determines the ability to collect radiation from a particular angle and direction unless optical averaging is done with sample motion or with an integrating sphere. In some instruments, multiple detectors at different locations are used. Three generations of workhorse filter instruments have supported wheat protein screening at Kansas State University from 1976 to the present time.

Page 198: Instrumental

181

Another type of near-IR instrument that Table IX. Discrete Wavelength Instrument Vendors uses discrete regions of the spectrum is the dis- Interference filters: crete source instrument (Table IX). This is used in the very near infrared region in the range of 850-1050 nm where silicon photodiodes work well as detectors. Each discrete source is a near-infrared version of a light emitting diode (LED). Each LED selected for a particular wavelength also has a very small interference Discrete source LED's + filter: filter attached to it in series to trim the optical Zeltex (formerly Trebor)

Futrex emission from the source. These multiple source Katrina Inc. discrete wavelength instruments are used primar- ily in a transmission mode. In this region of the4.00 spectrum where absorption bands are weaker, thicker samples commonly are used. Just as the 3"75 information found in the 1600-2500 nm region is 3.50 duplicated in the 1100-1600 region, the same information is duplicated again in the very near- 3.25 infrared region below 1050 nm where silicon3.00 detectors work well. The discrete sources are

Dickey-John Infrared Engineering Perten Insmunents Oxford Instruments (Foss Food Technology) Bran and Luebbe (formerly Teclmicon) Klett Zeltrex

1.

1 soybeans, 2 rye, 3 barley, 4 wheat nm

850 ....... 890 930 970 1010 1050

fired in sequence and in a brief time span data at each appropriate wavelength are collected. The Fig. 28. Very near-IR spectrum of an oilseed and

cereals. plot shown in Figure 28 illustrates that a measur- able difference in the whole seeds of three cereal grains and that of a high protein oilseed can be observed. These differences are the basis of such transmission instruments. Specialized instru- ments in this spectral region ratio fat to water or water to fat with reasonable success.

Grating M0n0chrom.ator~ Scanning instruments until recently were mostly grating monochromator instruments of

two basic types. The slow scan stepping motor driven sine bar grating rotation type accumulates signal and reference data completely at each wavelength before stepping to the next separate wavelength. Typically a signal reading, reference reading, signal reading, and dark current reading would be collected in sequence at each wavelength (grating angle). The resulting double beam (in time) function produces a quotient. The log 1/R or log 1/T is calculated at each point and the spectrum results from plotting each successive absorbance value.

Alternatively a fast scan vibrating grating system was used that accumulated reference intensities at all wavelengths before scanning the spectrum of the sample. These systems were equipped with automatic wavelength calibration check and correction by periodically inserting a

Page 199: Instrumental

182

wavelength standard into the optical path. Successful grating monochromators produced for use in the near-infrared are all characterized by having a very large grating with an f= 1.8-2.0. Holographic gratings blazed specifically for the near-infrared region and having an f number lower than those usually found on other optical instruments have provided success in the near-IR instrumentation field. The introduction of grating monochromator instruments into the near-in- frared field, exclusively held by filter instruments, allowed collection of adjacent wavelengths and the use of various plotting or global chemometric quantitative functions. The grating monochromator instruments, unlike the original filter instruments, provided a classical spectro- scopic look at the spectral features that resulted rather than being limited to a purely statistical approach.

Great changes have been made among the scanning near-infrared instruments, particularly within the last decade. Random wavelength access is readily available from any instrument that has scanning capability, but recently it has been possible to increase the duty cycle. Very rapid response photodiode detectors such as indium, gallium, arsenide (InGaAs) have been introduced to enhance the speed of data acquisition. Electronic wavelength switching as a means of scanning the spectrum or for random wavelength access provides opportunities for increased speed in the scanning or monitoring process. Two areas of electronic wavelength switching discussed here include the grating polychromator diode array and the acousto-optic tunable filter spectrometer (TFS). These scanning electronic wavelength switching instruments do not require moving parts, which has an advantage for industrial use.

Diode Array~ In the diode array instruments, the rays exiting a dispersive device (placed after the sample)

fall simultaneously upon each of the elements of a detector array. Data from each element in the array are polled with what could be described as electronic wavelength switching. This is in contrast to the classical grating monochromator, where rotation of the grating is necessary to aim a particular ray through the monochromator exit slit before traversing the sample and hitting the detector. Diode arrays have become commonplace in the last two decades in the UV and the visible region of the spectrum, where the technology of silicon photodiode arrays has been highly developed. Ever since Hewlett-Packard introduced a diode array UV detector for high perform- ance liquid chromatography and a similar laboratory benchtop UV spectrometer, a drastic change has come about in UV and subsequently fluorescence instrumentation. In the very near-infrared region (850-1050 nm) a silicon photodiode array can be used.

The engineering for silicon photodiodes and instrumentation in this region is advanced and silicon arrays are produced at a relatively low cost. However, at the longer, more commonly used wavelengths within the near-infrared region, the arrays are considerably more expensive. Germanium as a choice to extend the wavelength range comes at the expense of having a higher than desirable noise. InGaAs arrays work quite well at ambient temperature but cut off

Page 200: Instrumental

183

at a 1700 nm limit. An extended range InGaAs detector that reaches 2400 nm requires cooling and such a detector array is still expensive and each element is limited to small dimensions. Two technical advances have made possible modern diode arrays for spectroscopic instruments. The development of excellent photovoltaic devices and the use of memory chips to store correction coefficients to compensate for the difference in sensitivities of each different element in the diode array. Silicon photodiode array instruments in the near-infrared have been used for specialized devices such as octane analyzers for gasoline. More recently, InGaAs array instru- ments have been produced for the more commonly used region of the near-infrared spectrum which makes it possible to use the same wavelengths used previously in other types of near-infrared instruments.

Several vendors of the diode array type instrument are listed in Table X along with the vendors of other types of scanning instruments. In particular the diode array instruments of LT Industries and those of Perten Instruments require comment. In the instruments of both of these companies, white light going through the sample proceeds through the entrance slit of a polychromator that has a concave grating with a low f number. Located on the Roland circle with respect to the grating, is an array of either 256 or 512 InGaAs diodes. The diodes are spaced appropriately, and in one instance, the array has diodes of 100 ~tm in height by 30 l.tm in width that are spaced on 50 ~m centers. Typically the optical range covered by an array of this type is 800-1750 nm. At the high end, the sensitivity is somewhat reduced beyond 1700 nm. Such an array may be operated with thermal electric cooling although ambient temperature operation may be used. The LT Industries power scan instrument operates with fiber optics and uses multiplexing in order to perform analysis with remote site access at several different sites with the same basic optical instrument. The Perten Instruments version is a table top device which features a 5 inch diameter optical stage to handle large heterogeneous samples. Various specialized sampling devices have been designed.

The use of diode array instrumentation in the near-IR region of the spectrum for the kinds of sampling commonly done in that region has two limitations. The cost of the near infrared diode arrays is an issue in some regions of the spectrum. Beyond 1700 nm, a specially doped InGaAs array operates well only with thermoelectric cooling to provide a high D*. Addition of this and controlling electronics contributes to the cost. InGaAs arrays operating at room temperature have an excellent D rating but only in a limited range from 800 to 1700 nm. Ge arrays are available and operate throughout the region, but unless a particularly pure version of Ge is used, they tend to operate with higher noise that decreases their D* and desirability.

A diode array instrument requires that white light is fed into the sample and after exiting the sample, this radiation enters the entrance slit of the grating polychromator. In some cases having white light enter the sample is undesirable to have. If a photochemical degradation of the sample occurs, this would be an undesirable method for spectroscopic analysis. In the case of

Page 201: Instrumental

184

Table X. Scanning Instrument Types and Developers Electronic wavelen~h switching" Diode arrav eratin~ t~olvchromator

University of Washington silicon range photodiode (CaUis et al.) Perkin-Elmer (silicon range octane instrument) LT Industries InGaAs range (Powerscan) Perten Instruments InGaAs parallel array Buehler Insmmaents (futtwe model) Zeiss Instruments

Electronic Wavelength switching: Acousto-Optic Tunable Filter Random Access Spectrometer Kansas State University research Model (Wetzel/Eilert) Brimrose Insmmaents of North America Fiber Tech Rosemont Analytical Inc. (industrial PbS system) Bran and Luebbe (octane analyzer) Various one-of-a-kind homemade systems

Interferometer: Fourier Transform Spectrometers Bomem/Hartman & Braum (Canada) Midac (Calif.) Bruker (Germany) Mattsen (Wisc.) Nicolet (Wisc.) Buehler (Switzerland) Bio-Rad Digilab (Mass.) Bran and Luebbe (Germany) ATI (Wisc.)

Gratine Monochromator: v

USDA (Beltsville) research model (Norris/Massey) Perstorp Foss NIR Systems Guided Wave LT Industries Analytical Spectral Devices Bran and Luebbe (formerly Technicon)

slurries where scattering can be produced by either nonabsorbing or absorbing particles, the total amount of radiation exiting the sample with the correct trajectory to enter the polychromator will be limited. Predispersion eliminates the short wavelength rays that are scattered more, leaving only the potentially absorbed rays to be collected and intercepted by the detector. Another factor to be considered is that the elements in a diode array can be placed physically only just so close together. Therefore, gaps inevitably are present between the actual elements of the array. Radiation that falls into the crack is lost completely. Interpolation of signals from adjacent pixels probably would be representative of the lost radiation but that cannot contribute to the overall intensity in the region lost. In addition to the complete instruments just described, there are modules described as "a spectrometer on a circuit board" that that can be plugged into a PC. For specific information on the various diode array instruments, the reader is referred to the companies listed in Table X.

Page 202: Instrumental

185

Ar Tunable Filter Spectrometer Another method of achieving near-IR spectroscopic scanning and random wavelength

access with no moving parts is the acousto-optic tunable filter spectrometer. Acousto-optic tunable filter spectrometers allow the taking of random wavelength accessed data without the need to sweep through all data points. However, scanning by acquisition of data at sequential points is an option. The main feature of this approach is that no moving parts are required, which makes an industrial monitor based on this technology attractive. It has been the goal of the author of this chapter and his coworkers to develop near infrared acousto-optic tunable filter process monitors for on-line application. Based on early work conducted in our laboratory, a patent application was filed and subsequently granted for a quantitative instrument based on this technology (10). Quantitative data on corn oil in freon as well as numerous spectra were made public at the 1987 American Chemical Society meeting in Denver (11). Acousto-optic tunable filters (AOTF' s) were proposed in 1969 by Harris (12). There is some similarity of an AOTF to an acousto-optic modulator that is common in everyday use such as in a laser printer. In the modulator, ultrasonic energy fed to an acousto-optic crystal through which the light must pass alternately transmits or blocks the light. In tunable filter acousto-optic devices, a piezoelectric transducer bonded to an acousto-optic crystal (usually tellurium dioxide) is used to insert ultrasonic energy into the crystal. A particular, tuned, optical frequency passes through the filter corresponding to the RF (ultrasonic) tuning frequency applied (the crystal is designed to be tuned within a particular wavelength range). The optical frequency response curve is dependent on the design of the solid state device. An ultrasonic absorber is placed at the opposite side of the crystal. A pulsed mid-IR industrial stack monitor based on a terinary mixture IR-transmitting crystal was introduced by Westinghouse in the late 1980's. Pulsing that device was necessary because the thermal conductivity characteristics of the crystal required allowing time for cooling between pulses. The original 1986 continuous wave version of the acousto-optic tunable filter spectrometer (TFS) instrument in our laboratory was built around a custom designed TeO2 crystal using mostly components scavenged from other near infrared instruments. What we developed over a period of years (13) was a high quality, very rapid instrument. In optical characteristics, overall performance, and quantitative analysis it is very competitive with both the commercial grating monochromator instruments and FF-NIR instruments (14). A particular TeO2 AOTF device and frequency synthesizer based instrument performed well with a thermoelectrically cooled PbS detector, a phase sensitive detector amplifier, and appropriate software (15). With this advanced intermediate version, quantitative data were collected to fully test the instrument, and experiments were performed to show wavelength reproducibility as well as linearity. See Figure 29 in which the spectrum of 100% toluene is compared with a 1" 1 mixture of toluene and benzene from which the benzene spectrum has been subtracted.

Page 203: Instrumental

186

An effort to take advantage of the speed of the electronic wavelength switching was done by incorporating an Epitaxx Inc. (Los Angeles, CA) phosphorous doped InGaAs detector. This thermoelectrically cooled photovoltaic detector had a rapid operating speed and the phosphorous doped version extended the wavelength range to 2400 nm, considerably beyond the 1700 nm cutoff of a conventional InGaAs detector. The research model we produced incorporated Glan Thompson polarizers that gave a high efficiency of polarization. They transmit in the region of Fig. 29. Spectral subtraction showing KSU TFS instru-

ment performance. Spectrum 1 is a toluene (neat) ~ - interest and provide good rejection when trum. Spectrum 2 is the result of subtracting a benzene crossed. A blocker was added to give geometric spectrum from the spectrum of a 1"1 mixture of toluene restriction that did not rely completely on the and benzene. tuning efficiency and the polarizer efficiency to eliminate untuned radiation and the tuned ray not being used. This instrument was tested as a flow through monitor (Figure 30) by using HPLC pumps and a gradient programmer to produce calibrations on binary mixtures (16). Spectral subtraction was used to prove wavelength repro- duction and linearity of response similar to that shown in Figure 29. Software digitally control- led wavelength reproduction is extremely good. It is an advantage over moving grating systems and comparable to FT-NIR wavelength repro- Fig. 30. Scans at 1 second intervals with KSU Acousto- duction. One feature of an acousto-optic TFS is optic TFS instrument of flowing liquid from 100% hexane

to 100 % benzene. the use of random wavelength access to provide a relatively high duty cycle compared to grating monochromators and other scanning instruments. This feature was partially responsible for the excellent quantitative success.

The InGaAs detector equipped instrument was capable of performing 480 analyses using a two-wavelength expression in three seconds. This amounted to an analysis time of 8.3 milliseconds. An invited talk at the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy on this subject was entitled "Fastest Gun in the West" (17). Because an acousto-optic TFS is completely software controlled, isophotonic data accumulation may be used to enhance the signal-to-noise ratio at wavelengths where there is shortage of radiation intensity. A longer

Page 204: Instrumental

187

accumulation time was programmed to enhance the signal-to-noise where needed. Other wave- lengths where there was plenty of signal, either due to the fact that the instrument was transmissive and sensitive in that region, or that there were no strong absorbers in that region could be sampled for a much shorter period of time. This software-controlled, interactive, data acquisition enhanced the quantitative performance in select cases where low signal was a problem.

Commercialization of a quantitative acousto-optic TFS instrument based on the working experimental version was begun through cooperation of the Kansas effort with the Elmsford, New York division of Bran + Luebbe Analyzing Technolgies. That company introduced an instrument under the name InfraAlyzer AOTS ~ at the 1990 New York meeting of the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy. After closing the American facility, the parent office of Bran + Luebbe (Nordestadt Germany) reintroduced essentially the same instrument at a later date under the name InfraPrime | as a high cost end processing monitoring device for measuring octane number in the petroleum industry and for selected industrial monitoring in the European chemical industry. That version (limited to InGaAs range) used the two tuned rays in a double beam mode for monitoring and referencing.

More recently, Brimrose of America Inc. (Baltimore, MD), a well established OEM supplier of optical devices started producing AOTF devices as an OEM supplier and subsequently aggressively built an instrument company based on acousto-optic TFS. They offer an industrial version for industrial monitoring, a table top instrument, and various specialized instruments. With the very rapid expansion of this company and its product line, including dedicated instruments for analyzing pharmaceutical tablets at the rate of 25 per second and a rapid fire single seed sorting device for high oil, low oil, and reject categories, it is apparent that acousto-optic TFS instruments are at last challenging the market previously dominated by grating monochromator and interference filter instruments. A special light weight, low power consumption acousto-optic TFS instrument the size of a man's wallet custom designed by Brimrose for NASA is scheduled for a space flight near the turn of the century.

Fourier Transform (Interferom~try) Fourier Transform Spectroscopy (FTS) has been the method of choice in the mid-infrared

region for decades. Throughput of an interferometer instrument is greater because, unlike a grating monochromator, it has no entrance or exit slits. In the mid-infrared region there are two distinct advantages including the multiplex advantage and the throughput advantage. These same advantages would be expected for FI'-NIR, but the detector sensitivity and source intensity are relatively high in this region of the spectrum, so the IR throughput is less of an issue. Also the limitation of the dynamic range of the A/D converter results in leveling off of the signal-to-noise ratio at a moderate throughput level, negating any increased throughput beyond that level. The advantages that we expect to get from FT-NIR in comparison to a grating monochromator include resolution, sensitivity, and precision of both the wavelength and intensity readings. High

Page 205: Instrumental

188

resolution, band shape precision, and particularly wavelength precision may be advantages when dealing with narrow band measurements. In dealing with food and agricultural commodities, narrow band spectra are not too often encountered. For application to petroleum products, such as octane measuring instruments, narrow band data are more of an issue. This is true because a slight shift in the wavelength could cause a large change in the quantitation.

In an interferometer, a beam of radiation from the source entering the interferometer encounters a beam splitter. This optical device reflects approximately half the incident radiation and transmits the other half. In one pathway, a second mirror is encountered, and the radiation coming off the second mirror rejoins the rays coming straight through the beamsplitter to proceed onward to the sample target. Because the second mirror is moving, the pathway to and from the movable mirror will be variable as a function of time. At different mirror positions, a difference in the two path lengths produces interference. Data accumulated during the time of oscillation are subjected to fast Fourier transformation. The optical frequency resulting from the inter- ferometry of a broad range radiation beam is a cosine function of the difference between the two mirror paths.

In the mid-infrared, the requirement for high spectroscopic resolution was a very good reason to go to FI'-IR. Formerly, two reasons existed for not introducing the Fourier transform technique commercially in the near-infrared. First, the cost of FT instruments during the developmental period of modem near-infrared was high. Secondly, with radiation from all the wavelengths simultaneously hitting the detector, the ability to discriminate between small intensity differences was regarded as a limitation. The linear dynamic range of the A/D converter overtakes the throughput limitation when we strive to increase the signal in a near infrared interferometer type of instrument useful for application to quantitative analysis. At the present time, the cost of interferometers has decreased and because of advances in electronics, adding more bits to the A/D converter is no longer economically prohibitive. Thus the range of the A/D converter presently can accommodate small differences between large signals.

The author of this chapter had the opportunity to evaluate a commercial FT-NIR instrument, the Bomen MB-155 in 1991, when the A/D range was yet a presumed detriment. It performed for quantitative purposes in a comparable fashion to a commercial grating monochro- mator instrument and to a homemade acousto-optic (TFS) near infrared instrument (14). More recently an evaluation was made at KSU of a Nicolet Magna bench FT-NIR equipped with a fiber optic probe (18). Quantitative results with homogeneous solid samples were excellent. For heterogeneous samples, averaging of replicate probing was required with the geometry and dimensions of the probe that was used. In the opinion of this author, it is safe to say that FT-NIR is here to stay in quantitative as well as qualitative applications. Quantitatively it performed well for five-component liquid test mixtures, for emulsions, and for granular solids. Spectral subtraction with FT-NIR is useful. In Table X are listed numerous vendors of FT-NIR

Page 206: Instrumental

189

instruments. Many of these companies are recognized as long time mid-infrared manufacturers. Most of these use a Michelson type of interferometer. Some do use the comer cube optical configuration. An alternative to this is a polarization interferometer designed specifically for near infrared for qualitative analysis industrial I.D. inspection. During just the past decade alone the diode array instruments, the acousto optic TFS instruments, and the FT-NIR instruments have become competitive in the near infrared field. Currently several alternatives are available for routine and specialized use.

OBTAINING AND SORTING OUT INFORMATION ABOUT NEAR-IR AND IT'S APPLICATIONS

In the past three decades, reliable written information about near-IR applications has not necessarily always been available. For regular attendees of national meetings in North America including the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, the Federation of Analytical Chemistry and Spectroscopy Societies, Eastern Analytical Symposium, and the International Diffuse Reflectance Spectroscopy Conference (Chambersburg), this has not been a problem. In the process of teaching numerous short courses at various cities under the sponsorship of the Society for Applied Spectroscopy, Eastern Analytical Symposium, the American Association of Cereal Chemists, the American Chemical Society, and other groups, we have accumulated a collection of information on topics such as the theory, spectral features, fundamentals, strategies for developing a method, the optics of sampling, instrumentation for filters, instrumentation for scanning instruments, smart systems, and applications. Much of that material is included in the text of this chapter. Handout materials that have been developed over the years for use in these short courses have been distributed to participants in the short courses. Through the Council for Near Infrared Spectroscopy, similar material was distributed to teachers of courses of instrumental analysis, in chemistry departments in the United States and Canada, who responded to the offer to furnish them.

In response to an invitation to develop a near-infrared course early in the development of this field, this author had the good sense and good fortune in recruiting a prominent spectroscopist, Dr. Tomas Hirschfeld, from outside of the field. We met in advance of this course at his location at Lawrence Livermore Laboratory in Livermore, California to plan the topics, the order, and the coverage. Subsequently, we repeated the offering of our course in a condensed version at an Eastern Analytical Symposium a half year later. Not only was Hirschfeld the headliner for the courses, but every lecture he gave revealed the results of his recent thoughts about the near-infrared field that at the time was new to him. When working with an intellectual giant like Dr. Hirschfeld it is difficult to sort out the ideas or feelings about a subject that are your own and the notions that have been transplanted to your mind as a result of lectures, discussions, conversations, and gleanings from extemporaneous informal lectures. He used to show the sketch of a bee and point

Page 207: Instrumental

190

.5

.3

. T__~ . . . . . . . . . region of the spectrum to the far-IR. The near-IR t2oo 16oo " ~o'oo "2~o

,,.,e,.~.~ ~,~ and very near-IR regions are enlarged to show Fig. 31. Benzene at different concentrations in a solvent that absorption does indeed occur in these re- transparent in the near-IR, gions.

In the early days most information was advanced by marketing people from the most active instrument companies. Quantitative near-infrared spectroscopic analysis was simply not a recognized field in analytical or spectroscopic circles. Everyone was forced to acknowledge the fact that near-infrared worked for quantitative purposes but understanding why it worked was not obvious. Some of the explanations developed for the short course were used in the cover feature article in the A pages of Analytical Chemistry years ago (6). This material has served as a primer for those unfamiliar with the field. In that article, an attempt was made to make near-infrared more palatable to practicing analytical chemists and classical spectroscopists. Since that time other review articles and books have appeared (19-26). In general those monographs, actually written by two or three authors tend to have greater continuity than edited books that included contributions of many authors. On the other hand, in these books, each individual subject is treated by a specialist in that field.

Initially when the production of new methods was done by applications chemists working for instrument companies and by some of their industrial customers, very little was actually published. In that frenzied period, we were concerned about the calibration of the day or month that could produce an instrument sale. If it was in fact published, it was usually out of date by that time or soon thereafter. At one time the only way to know the latest advances was to have attended every meeting where oral presentations were made on the subject. Our handout material for early short courses consisted of mostly photocopies of abstracts of presentations from meetings. In this way at least the analyte and the matrix material of the application was identified and the group of people working was also given so that if necessary they could be contacted directly. Actually in the near-infrared field we have gone from a shortage of published information to a condition of having more published information than we can sort out or keep up with.

out that "near-IR analysis like the bee should not work". The aerodynamics of a bee are not suited to flying "but it flies anyhow". Near-infrared also follows Beer's law as illustrated in Figure 31 by varying levels of benzene in a nonabsorbing solvent in the near-IR region. If anyone still has doubts about the comparatively weak absorptions in the near-IR region, refer to Figure 32 which shows a spectrum of benzene from the ultraviolet

Page 208: Instrumental

4

Fig. 32. Benzene spectrum from ultraviolet to far-IR regions. Near-IR (right) and very near-IR regions (left) are enlarged to show absorptions. (Note: enlargements are not to the same scale.)

Page 209: Instrumental

192

Expecting to use cookbook applications does not necessarily work. As an analytical chemist, upon finding a method published in a journal article having to do with a chromatographic or spectroscopic procedure, I would presume that if we followed the printed procedure to the letter that we would have a reasonable expectation of success. Such is not the case with published methods in near-infrared. To use a UV vitamin determination method, some means of separation or some work-up procedure prescribed would have to be followed carefully. When it was followed, we could expect that interferences would have been dealt with by a prior separation procedure or by a chromatographic procedure prior to quantitation with the ultraviolet spectroscopic measure- ment. The advantage of no required separation, "user friendliness", and speed touted for near-infrared is also a serious disadvantage for those expecting to read the literature and immediately apply the same calibration equation coefficients, etc. and expect to get good quantitative results. Various universal calibrations have been developed. Some of these have actually worked well provided that their applicability was well defined and adhered to.

The primary value of the reporting of a particular method development in the literature is that the reader knows that at least someone was successful with that particular analyte in that particular matrix. When an author or speaker reports only a correlation and no validation, this is a case of "buyer beware". This word of caution does not mean that none of the information given is of any value whatsoever. When discrete regions of the spectrum have been chosen by another worker, their identity is certainly of value. Also, coefficients supplied may be examined for their sign and relative magnitude and the success in terms of the statistical parameters provides a benchmark for the next worker.

Numerous reports are found on calibration transfer with the same model of the same instrument and perhaps within the same corporation or organization method development does not want to be duplicated and it is worth a considerable effort to assure calibration transfer. Perhaps no organization has had more experience with this in terms of numbers of instruments than the Federal Grain Inspection Service facility in Kansas City, MO. Calibration maintenance is an issue where a good deal of serious near-IR work is done on a routine basis. In fact, large companies such as Cargil and Raison Purina that have many units in the field analyzing a greater variety of analytes in various sample matrices have a more complicated task. There is a good deal published on the chemometrics associated with near-infrared and a number of software packages are available from third party suppliers. This represents important progress in the field. Now that near-infrared has become a legitimate part of the analytical and spectroscopic community, a number of articles are published in journals such as Applied Spectroscopy as well as journals primarily devoted to analytical chemistry. In addition the Journal of Near-lnfraredSpectroscopy is devoted exclusively to this subject. A considerable amount of literature is available in joumals associated with various fields in which near-infrared is applied. Now that more is being written and said about

Page 210: Instrumental

193

near-infrared there is no shortage of information but careful thought and discrimination is needed now to sort out the useful from the confusing.

Early commercialization of cheometric based near-infrared instruments for wheat enabled quantitative near-IR spectroscopy to reach the prominent position it now enjoys in the opinion of the author. When only three near-IR instrument manufacturers coexisted (mid 1970's), Dickey- John, Neotec, and Technicon, the following engineers made that commercialization possible: Dave Funk and Hugh Schoen (Dickey-John), Bob Rosenthal, Don Webster, Ron Moen, and Issac Landa (Neotec), and Bob Rachlis, Ed Stark, John Judge and Lee Pearlman (Technicon).

REFERENCES:

1. Fuller, M.P. and Griffiths, R.P., "Diffuse Reflectance Measurements by Fourier Transform Spectroscopy", Anal. Chem., 50, 1906, 1978.

2. Kaye, W., "Near-Infrared Spectroscopy (a review) - II. Instrumentation and Technique", Spectrochim. Acta, 7, 181-204, 1955.

3. Whetzel, D.B., "Near-Infrared Spectrophotometry", Appl. Spectrosc. Rev., 2(1), 1-67, 1968. 4. Goulden, J.D.S., "Diffuse Reflection Spectra of Dairy Products in the Near Infra-red

Region, J. Dairy Sci., 24, 242-251, 1957. 5. Massey, D.R. and Norris, K.H., "Spectral Reflectance and Transmittance Properties of

Grain in the Visible and Near Infrared", Trans. Amer. Soc. Eng., 8(4), 589-600, 1965. 6. Wetzel, D.L., "Near-Infrared Reflectance Analysis - Sleeper Among Spectroscopic Tech-

niques",Anal. Chem., 55, l165A-1171A, 1983. 7. Rose, J.J., "Compound Identification Using High Speed NIRA", the Pittsburgh Conference

on Analytical Chemistry and Applied Spectroscopy, Atlantic City, NJ, 1983, paper #187. 8. Mark, H.L. and Tunnell, D., "Quantitative Near-Infrared Reflectance Analysis Using

Mahalanobis Distances", Anal. Chem., 57, 1449-1456, 1985. 9. Mark, H., Principles and Practice of Spectroscopic Calibration, John Wiley & Sons, New

York, 1991. 10. Kemeny, G.J. and Wetzel, D.L., "Optical Analysis Method and Apparatus Having

Programmable Rapid Random Wavelength Access", U.S. Patent 4,883,963, 1989. 11. Wetzel, D.L., Kemeny, G.J., and Eilert, A.J., "Using an Acousto-Optic Tunable Filter in

Near-Infrared Spectroscopy", American Chemical Society Meeting, Denver, CO, 1987. 12. Harris, S.E. and Wallace, R.W., "Acousto-Optic Tunable Filter", J. Opt. Soc. Amer., 59,

744, 1969. 13. Eilert, A.J., "Acousto-Optic Tunable Filter Spectroscopic Instrumentation for Quantitative

Near-IR Analysis of Organic Materials", PhD. Dissertation, Kansas State University, 1995. 14. Wetzel, D.L. and Eilert, A.J., "Quantitative FT-NIR of Thermochemical Properties of

Industrial Organic Fluids", Proc. SPIE-Int. Soc. Opt. Eng., 1575, 523-524, 1992. 15. Wetzel, D.L. and Eilert, A.J., "Quantitative Analysis with a High Duty Cycle Solid State

Random Wavelength Access Near-Infrared System", the Pittsburgh Conference on Anal- ytical Chemistry and Applied Spectroscopy, New Orleans, LA, 1992, paper #1135.

Page 211: Instrumental

194

16. Wetzel, D.L. and Eilert, A.J., "Fast Liquid Flow Composition Monitoring with an Acousto-Optic Tunable Filter NIR Spectrometer", the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Chicago, IL, 1991, paper #478.

17. Wetzel, D.L., "Fastest Gun in the West!", the Pittsburgh Conference on Analytical Chem- istry and Applied Spectroscopy, New Orleans, LA, 1992, paper #1135.

18. Wetzel, D.L. and Sweat, J.A., "FT-NIR Comparative Performance for Complex Samples", Mikrochim. Acta [Suppl.] 14, 325-327, 1997.

19. Weyer, L.G., "Near-Infrared Spectroscopy of Organic Substances", Appl. Spectrosc. Rev., 21(1&2), 1-43, 1985.

20. Martin, K.A., "Recent Advances in Near-Infrared Reflectance Spectroscopy", Appl. Spec- trosc. Rev., 27(4), 325-383, 1992.

21. Burns, D.A. and Ciurczak, E.W., Handbook of Near-lnfrared Analysis, Marcel Dekker, New York, 1992.

22. Williams, P.C. and Norris, K.H., Near-lnfrared Technology in the Agricultural and Food Industries (2rid ed), The American Association of Cereal Chemists, 1998, in press.

23. Murray, I. and Cowe, I.A., Making Light Work: Advances in Near Infrared Spectroscopy, VCH, New York, 1992.

24. Marten, G.C., Shenk, J.S., and Barton, F.E.II, Near Infrared Reflectance Spectroscopy (N1RS): Analysis of Forage Quality, U.S. Department of Agriculture, Agriculture Hand- book No. 643, 1989.

25. Davies, A.M.C. and Williams, P., Near Infrared Spectroscopy: The Future Waves, NIR Publications, West Sussex, 1996.

26. Osborne, B.G., Fearn, T., and Hindle, P.H., Practical NIR Spectroscopy with Applications in Food and Beverage Analysis, 2nd ed., John Wiley and Sons, New York, 1993.

Contribution no. 98-137-B Kansas Agricultural Experiment Station, Manhattan.

Page 212: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 195

Analysis of Fatty Acids

J. M. King and D. B. Min

Department of Food Science and Technology, The Ohio State University, 122 Vivian Hall, 2121 Fyffe Road, Columbus, OH, 43210

I. Introduction

There has been a great interest by consumers for nutritious foods. This interest has caused the food industry to work on decreasing the caloric content of foods while increasing the nutritiousness of their products. These products are high fiber breads, cereals and other bakery products and low fat or non-fat foods where fats and oils are replaced by fat mimetics.

Fat substitutions in the formulation of food products and the health claims associated with the increased health benefits have caused the FDA to review once again their labeling policies for foods. One of the areas covered by the FDA is fat content, with specific rules relating to fatty acid content. These rules are in the Code of Federal Regulations (CFR) 21, Part 101.9, "Nutrition Labeling of Food" (1). The information requires that fatty acids be calculated as triglycerides in three categories: saturated, polyunsaturated and monounsaturated. Polyunsaturated fatty acids are defined as the cis,cis- methylene-interrupted type, saturated fatty acids are defined as the sum of all fatty acids containing no double bonds and monounsaturated fatty acids are defined as those of the cis-monounsaturated type.

The analysis of saturated, monounsaturated and polyunsaturated fatty acids by gas chromatography will be covered in detail and will focus on improvements made during the last ten years.

Page 213: Instrumental

196

I1. Lipid Extraction

Not much has changed since the Folch et al (2) and Bligh and Dyer (3) methods of lipid extraction. Most scientists have used chloroform/methanol in the ratio of 2:1 to extract lipids when further analysis of fatty acids is required. Both methods involve the use of an aqueous salt solution to produce a biphasic system. The non-lipid materials are in the aqueous phase and the lipid materials are in the chloroform phase. Folch et al. (2) reported that the ratios of chloroform to methanol to water must be 8:4:3 by volume, respectively. Several researchers (4, 5, 6) have used various extraction procedures and have found that the chloroform/methanol procedure worked best for extracting all classes of lipids. One experiment where methylene chloride was substituted for chloroform showed no statistical difference between the two solvents for extracting total fat, fatty acids and sterols from various foods (4).

The solvent chloroform/methanol is widely used for the extraction of lipids, but there are special cases where the method of using this solvent is varied or where other solvents are required for complete extraction of lipids (7, 8, 9). Soxhlet extractions have sometimes been used to remove lipids from seeds (10, 11, 12). Christie (9) reported that water saturated n-butanol was recommended for the extraction of lipids from cereals or wheat flour due to the lipids which are bound by the starch. Hammond (7) recommended a three part extraction for wheat flour involving acid hydrolysis for total lipids and a separate sequence extraction for non-starch and starch lipids. The non-starch lipids are extracted with cold water saturated n-butanol and the remaining residue is then washed with methanol and extracted with hot water saturated n-butanol. Christie (13) also suggested that an ethanol/diethyl ether mixture may be used for lipoproteins and isopropanol/hexane solvent for lipid extraction from animal tissues. Christie recommended the use of a modified Bligh and Dyer (3) method for large extractions where the filtering step is utilized before the addition of the aqueous salt solution and a modified Folch et al. (2) method where the methanol is added first followed by the chloroform for a more complete lipid extraction. Christie stated that plant tissues must be extracted initially with isopropanol to deactivate enzymes. These special extraction procedures are important when complete analysis of all lipid classes is

Page 214: Instrumental

197

required. The mixture of chloroform/methanol is adequate for fatty acid analysis mainly from triglycerides and extraction is not required for salad and cooking oils (8). Sometimes further purification of the lipids is performed, more recently with supercritical fluid chromatography (14), but most often with thin layer chromatography (15, 16, 17) and/or silicic acid column chromatography (18, 19, 20).

III. Fatty Acid Derivatization

Many of the experiments in derivatization of fatty acids to esters are related to making the process of derivatization simplier and more rapid while retaining accuracy (21, 22, 23, 24, 25). There is also a concern for artifacts produced during derivatization which show up during gas chromatographic analysis as unidentified peaks (9, 26). These peaks may be due to the use of old or contaminated solvents or the inclusion of antioxidants such as BHT which itself can be derivatized. Christie (13) stated recently that when used at proper levels, which depends on lipid concentration, there should be no problem with BHT artifacts since BHT can be lost during the evaporation process and usually elutes at the solvent front.

First to consider is the need for saponification of the lipids in order to release the fatty acids. Saponification is typically done using KOH or NaOH in methanol or ethanol (13). This will help separate the fatty acids from non- saponifiables. Mild saponification conditions must be used to prevent changes in double bonds of polyunsaturated fatty acids.

Lipids can be transesterified directly without hydrolysis. The main derivatization methods are acid catalyzed esterification of free fatty acids/transesterification of bound fatty acids or base catalyzed transesterification. The base catalyzed transesterification does not derivatize free fatty acids so samples and solvents must be anhydrous to prevent hydrolysis of triglycerides (7, 13). Typical base catalyzed derivatization reagents are 0.5M sodium methoxide in anhydrous methanol or 0.2M potassium hydroxide in methanol. The acid catalyzed derivatization requires 5% HCL in methanol, 1% sulfuric acid in methanol or 12% boron trifluoride in

Page 215: Instrumental

198

methanol as reagents, with the later causing many problems related to artifact formation and loss of polunsaturated fatty acids (7, 13, 27). Christie (13) stated that boron trichloride could be used in place of boron trifluoride as a more stable reagent. Internal standards such as heptadecanoic acid (C17:0) for C8:0 to C22:0 fatty acids and isocaproic acid (C7:0) for volatile fatty acids (C2:0 to C7:0) are added prior to the derivatization step (7).

Other reagents are available for transesterification to shorten the derivatization time. One of these is tetramethylammonium hydroxide in methanol which transesterifies triglyceride fatty acids to methyl esters (22, 25). This reagent minimizes ihe losses of C14:0 and C15:0 fatty acids and unsaturated C18 isomers in the analysis of plant oils, margarine, lard and animal tissues (25). Williams and Macgee (28) used trimethylphenylammonium hydroxide to form salts with the fatty acids which are then pyrolized during injection to form methyl esters. Garces and Mancha (21) used a complex mixture of reagents to digest plant tissues and form methyl esters all in one step. The reagent contained methanol, heptane, 2,2-dimethylpropane and sulfuric acid with or without either benzene or toluene. The method was good for samples containing a large amount of triacylglycerols or water. A nonpolar solvent such as toluene can help solubilize the nonpolar lipids.

Diazomethane is used for esterification for volatile short chain fatty acids in dairy products (7, 13). Because this reagent is very hazardous it is not recommended for transesterifying hydrolyzed lipids. Christie (13) recommends the Christopherson and Glass (29) method using sodium methoxide in methanol. Hammond (7) recommends the use of potassium hydroxide in methanol. Highly volatile fatty acid samples have also been analyzed as butyl esters (30). Sometimes a combination of esterification methods are used for samples containing both free fatty acids and bound fatty acids (31). Fatty acids can be analyzed without derivatization, but most researchers prefer to prepare fatty acid methyl esters (32).

Page 216: Instrumental

199

IV. Gas Chromatographic Analysis

The next step is to choose the type of gas chromatographic system for fatty acid analysis. This includes the selection of the column phase, the temperature of analysis, the type of injection, the type of detector and whether supplemental analysis will be necessary.

There are two kinds of columns: packed and capillary (7, 13). There was another column type used for a short period of time called support coated open tubular (SCOT) which was essentially a wide bore column of 0.5 to 1.25 mm internal diameter (i.d.) with the liquid phase coated on a fine powdered support (9). Packed columns can be made of glass or steel, are 2 to 4 mm i.d. and 1.5 to 2.5 m long. They are packed with a solid support such as deactivated diatomaceous earth coated with liquid stationary phase. The support must be inert to prevent interaction with the sample. Capillary columns also termed WCOT (wall coated open tubular) can be steel or glass and most recently are made of flexible fused silica. They are 0.25 or 0.32 mm i.d. and can be up to 100 m long. The inner wall is coated with liquid phase. There are also wide bore WCOT columns which have an i.d. of 0.53 or 0.75 mm (7, 33, 34).

The liquid stationary phases are either nonpolar or polar. The nonpolar phases are silicone polymers such as OV-1, SE-30 and SP-2100 and also Apiezon high molecular weight hydrocarbons which are not used as often as the silicone phases (7, 13). The retention times of unsaturated fatty acids on nonpolar phases are less than those of their saturated counterparts, whereas on polar phases the reverse is true. Polar phases are made of polyesters. Christie (13) describes four types with varying polarities. The highest polar phases are polar substituted alkylpolysiloxanes such as Silar 10C, SP-2340 and OV-275. The highly polar phases include polyethyleneglycol succinate (EGS), polydiethyleneglycol succinate (DEGS), EGSS-X (methyl silicone copolymer of EGS), and CP-Sil 84. Polyethyleneglycol adipate (PEGA), polybutanediol succinate (BDS) and EGSS-Y (similar to EGSS-X, but with more methyl silicone) are examples of medium polar phases. The low polar phases include polyneopentylglycol succinate (NPGS), EGSP-Z (copolymer of EGS with phenyl silicone), Carbowax 20M and Silar 5CP (50% phenyl and 50% cyanopropyl silicones). Highly pure polar cyanopropyl polysiloxanes have very

Page 217: Instrumental

200

high temperature stability up to 250~ (7). Stationary liquid phases are sometimes bonded or crosslinked to capillary columns especially Carbowax 20M (35, 36, 37). Carbowax 20M is also available in a modified form with 2- nitroterephthalic acid called FFAP. Hammond (7) reported that a majority of fatty acid methyl esters can be analyzed on this column. Some times a mixture of liquid phases is used to improve the resolution. A combination of SP 2310 and SP 2300 helped to resolve C18:3 from C20 fatty acids (38). The amount of liquid phase affects separation in packed columns, but not in capillary columns. Levels of liquid phase used in packed columns typically ranges from 5 to 20% by weight (28, 39, 40, 41,42, 43, 44). Capillary columns are coated most often at 0.20 and 0.25 micron thickness levels (37, 45, 46, 47, 48).

The common detectors are flame ionization (FID), electron capture (ECD), photoionization (PID)and thermal conductivity (TCD) (7,13). The FID detector is the one most widely used for fatty acid analysis. It should be operated at a temperature of about 20~ to 50~ above the final column temperature. The FID detector should give a linear relationship between its response and the carbon number of the fatty acids.

The injection technique is important to obtain accurate results (45). Samples may be injected directly onto the column, which is the common method for packed columns, or through an injection port. Split or splitless technique may be employed using an injection port (13, 48). Any of the techniques may be used for capillary columns. If the sample is introduced directly onto the capillary column, "cold trapping" is used (13, 46). The sample must be injected at a column temperature near the boiling point of the solvent used. Splitless injection requires that the sample be injected at a column temperature below that of the solvent's boiling point. This causes the solvent to form a film of temporary stationary phase which concentrates the sample (13). Split injection can be used to prevent column overload, but can give inaccurate results due to variations in sample volume, injector and detector temperatures and the way the syringe is handled. "Cold trapping" can minimize some of these problems (13). Christie (13) recommends a "hot needle" technique to prevent evaporation of the sample before complete insertion of the syringe needle into the injector. The sample is drawn all the way into the barrel of the syringe and the needle is preheated for a few seconds in the injector prior to

Page 218: Instrumental

201

pressing the plunger. The newest type of injection involves a temperature controlled injection port (13, 47). This prevents discrimination between fatty acid methyl esters of low and high volatility.

The gas chromatograph oven temperature can be controlled. Temperature programs are either run isocratically or at various rates. This depends on the type of sample analyzed and the information required. Short chain fatty acids can be separated isothermally, but longer chain fatty acids and complex mixtures usually require temperature programming to adequately separate peaks (13, 35, 48, 49). The final oven temperature must not exceed the temperature range of the column since high temperatures could damage the liquid phase.

The complete gas chromatographic system must be optimized to obtain accurate results. This topic was discussed in depth by Craske and Bannon (50). They described various subjects to optimize the gas chromatographic conditions and obtain accurate results. They discussed the use of a computor integrator and theorectical FID relative response factors to correct peak areas. Theorectical relative response factors have been proven to be accurate for all even numbered fatty acid methyl esters from C4:0 to C22:0 (50,51). Primary standards of saturated fatty acid methyl esters and saturated triglycerides should be employed to optimize the chromatographic system and the overall method, including derivatization. The easiest way to prevent errors during injection is to inject directly onto the column with a rapid depression of the plunger. Craske and Bannon (50) mentioned techniques to optimize a split injection procedure, which was discussed earlier. The detector can be optimized by adjusting the flow rates of the gases until a linear relationship is found between chain length and retention time for a complex mixture of fatty acid methyl esters. Craske (47) performed a collaborative study to separate instrumental errors from chemical sample preparation errors. Olsson et al. (52) developed a multivariate method for optimizing the analysis of fatty acid methyl esters. Accurate quantifications of fatty acids can be calculated by equivalent chain length and relative response factors only when the sample preparation and gas chromatographic conditions are optimized (51, 53, 54, 55). Equivalent chain length values were shown to vary with temperature gradient in linear

Page 219: Instrumental

202

temperature programmed gas chromatography, but for each temperature gradient the equivalent chain length factors can be predicted (54).

V. Analysis of Fatty Acids in Foods

Fatty acids can be analyzed without derivatization either on packed columns or capillary columns (7, 23, 34, 56, 57). When free fatty acids are analyzed as is, Hammond (7) recommends that they first be separated by thin layer chromatography. A typical liquid phase for free fatty acid analysis is FFAP (free fatty acid phase), which is an acidic form of Carbowax 20M (7, 32). The acid helps prevent tailing and hydrogen bonding on the column. Acid treated liquid phase columns have had problems with peak ghosting. This problem was solved by using formic acid vapor to compete for the adsorptive sites on the column (58,59). Underivatized fatty acid analysis is used more for analyzing volatile fatty acids of biological samples than for food samples (32).

Volatile short chain fatty acids of dairy products require careful derivatization and gas chromatographic analysis (13, 30, 40, 56, 57). These fatty acids can be esterified with diazomethane and injected directly onto the column (24) or they can be derivatized to butyl esters (30, 50). Even n-propyl esters have been recommended (7). Increasing the molecular weight through derivatization will prevent the loss of volatile fatty acids (9). On column injection should be used to prevent discrimination among fatty acids (13, 32). Many different phases are used to analyze dairy fatty acids including Stabilwax- DA and Nukol on wide bore columns (56, 57) and capillary columns with CP- Sil84, an example of which is shown in Figure 1 (13). Short chain fatty acids of coconut oil have been analyzed with an FFAP packed column after diazomethane derivatization (31).

Lipids from animal tissues have been analyzed mainly by capillary cloumns on various phases such as OV-275, Carbowax 20M and SP 2330 (60, 61, 62, 63). A wide bore capillary column was also used with OV-275 on Gas Chrom R (64). Most of the lipid samples were saponified (61, 62, 63) prior to the formation of fatty acid methyl esters with boron trifluride in methanol. Sawaya et al. (60) used potassium hydroxide in methanol for direct transesterification to

Page 220: Instrumental

203

la:1

m l k ~

111 0

i , 1 8 ~

" _3"'--' . . . . , __. i~ ~J.__ _ i L._ L

, J_ �9 , , �9 _ �9

5 2o 25 u m e ~

Figure I. Milk fatty acids (methyl esters separated on a fused silica column coated with CP-SiL 84 T M The oven was held at 30~ for 3 min, then raised at 8~ per rain to 160~ and was held at this point for a fur ther I0 rain. (Reprinted with permission from reference 13.)

detect pork in processed meat. The presence of C20:2 was a positive indicator of pork in a canned meat. Other supporting methods including immunoassy were required due to the variation of C20:2 in pure pork meat. The major fatty acids found in meat regardless of the source are palmitic, stearic and oleic acids (64). Other fatty acids found in meat are shown in Table 1 (64).

Lipids of seed and nut oils have been analyzed using capillary columns more often than packed columns in recent years and saponification prior to derivatization was employed (11, 12, 65, 66, 67, 68). Sosulski and Gadan (10) described a glass column packed with GP 3% SP 2310 and 2% SP 2300 liquid phases on Chromosorb W AW support for the analysis of chickpea lipids. They

Page 221: Instrumental

Table 1. Fatty Acid Composition of Lean Meata (Reprinted with permission from reference 64.) N 0

Beef Sheep Goat b f f a b Sawbardeer Horse Kangaroo p19 JA

Fatty acid ( W b (n=6) (n=6) (n=6) (n=7) (n=6) ( k 7 ) (rts)

Myristic (14:O) Palmitic (1 6:O) Stearic (18:O) Arachidic (20:O) Total safurafed

Palmitoleic (16:l) Oleic (18:l) Eicosamonoenoic (20:l) Docosamonoenoic (22:l) Total momnsaturaftxi

Linoleic (18:2M) Eicosadienoic ( 2 0 : 2 6 ) Linolenic (18:3w3) Eicosatrienoic ( 2 0 . 3 ~ 9 ) Eicosalrienoic (20.3M) Arachidonic f20:4M61 Docosatelraenoic (22 4 6 ) Eicosapentaenoic (20 5w3) 0 6 Docosapenlaenoic (22 5w3) 1 0 Docosahexaenoic (22 6w3) 0 1 Tofalpo@nsarVraled 8 8+/-2 2

2.9 23.3 13.6 0.4

40.24-2.5

4.3 37.8 0.2 0.1

42.4tl-2.7

3.8 0.1 1.2 0.2 0.4 1.4

2.0 0.22+/-0.06

2.3 21 .o 15.5 0.9

39.7+/-1.8

2.4 37.9

40.3+/-1.2

5.4 0.1 1.6 0.3 0.2 1.4

0.7 0.5 0.1

10.3+/-1.4

2.4 0.26+/-0.04

1.6 19.5 15.1 0.4

36.6+//-2.4

3.0 37.4 0.1

40.5+/-4 5

6.3 0.1 1.4 0.5 0.3 2.4 0.1 0.8 0.9 0.2

13.0+/4.5

2.8 0.36+/-0.15

0.4 16.6 14.0

0.3 31.34-3.3

2.1 24.6

0.2 26.94-4.6

14.7 0.1 2.8 0.3 1.4 5.2 0.2 1.9 1.9 0.1

28 .&/-5.6

3.2 0.91+/-0.27

0.3 16.1 11.4

0.2 28.0+/4.3

3.1 10.7

13.84-3.2

15.3 0.1 2.4 0.1 0.9 8.0 0.1 1.9 2.4 0.1

31.4+/-5.1

3.6 1.12+/-0.27

0.7 18.1 9.3

28.14-4.5

1.5 11.6 0.2

13.3+/-4.0

27.2 0.5 3.7

0.9 6.9

0.8 2.0 0.5

42.74-4.1

5.1 1.52+14l.3 t

0.2 14.6 12.3 0.6

27.7+/-2.8

1.1 18.1 0.2 0.1

19.544.5

19.5 0.3 3.6 0.2 1.3 8 7 0.4 1.4 1.9 0.6

37.9+/-5.4

4.0 1.37+/-0.32

1 1 21 5 10 7

33 3+/-1 9

2 6 31 2 0 6

34 4+/-2 6

176 0 6 0 6 01 0 5 4 3 05 01 05 01

24 9+/-2 8

18 0 0 75+/-0 12

a As g 100 g-l total fatty acids (4- s.d. where appropriate). b Number of muscle samples analyzed. c Ratio of linoleic acid metabolies to linolenic acid metabolites. d Ratio of PUFA to saturated fatty acids. A - indicates that the component was not detected (limit of detection about 0.02 g 100 g-l total fatty acids).

Page 222: Instrumental

205

used sodium methoxide in methanol to form fatty acid methyl esters. Various transesterification methods including basic methanol reagents (67, 68), acidic methanol reagents (39, 42, 43, 66) or boron trifluoride-methanol (12, 67) for derivatization have been reported. Senter et al. (11) used boron trichloride in methanol to form fatty acid methyl esters of walnut lipids. Kallio et al. (12) compared supercritical fluid extraction and Soxhlet extraction with diethyl ether to extract oil from turnip rapeseeds. Soxhlet method yielded 15% more oil than the supercritical fluid extraction method. The predominant fatty acids found in seed and nut lipids are oleic and linoleic acids. Artz and Saver (69) worked on improving the analysis of free fatty acids using supercritical fluid extraction and chromatography. Although the % relative error for the analysis of wheat flour replicate samples was less than or equal to 10%, the extraction efficiency of the method was greater than 99%. Sahasrabudhe (19) reported various solvent systems for the extraction of lipids from oats. The amount of each lipid class extracted varied with the type of solvent used. Solvents containing diethyl ether or alcohol extracted the most free fatty acids, n-Hexane alone or with diethyl ether extracted the highest amount of triglycerides. The choice of solvent therefore depends on the type of lipids in the samples.

Fruits have been analyzed for their fatty acid composition. Highbush blueberries and Schinus terebenthifolius berries both contained large amounts of linoleic, oleic and palmitic acids (41, 70). Blueberries may be a good source of essential fatty acids because they also contain a large amount of linolenic acid. The blueberries were extracted with chloroform-methanol (2:1, v/v). Higher amounts of essential fatty acids may be found if another solvent was used to extract the lipids. Moneam and Ghoneim (70) reported that the largest amount of fatty acids from schinus terebenthifolius berries could be extracted with light petroleum. This solvent worked better than diethyl ether or chloroform-methanol (2:1, v/v). Mango seeds were analyzed for lipid content to determine if they can be used as a source of fat rather than being a waste product of jelly production (20). The oil was extracted with n-hexane in a Soxhlet apparatus, separated into lipid classes by silicic acid chromatography and the fatty acids of the triglycerides were derivatized with sodium methoxide. These fatty acid methyl esters were analyzed on a packed glass column with 6% BDS on Anakrom ABS support. Palmitic, stearic and oleic acids were the

Page 223: Instrumental

206

main fatty acids. The large amount of stearic acid explains why the mango fat is solid at room temperature. They reported that mango fat resembled cocoa butter.

Many lipid samples contain isomers of fatty acids, especially fish oils (15, 16, 17, 35). Although separation of geometric and positional isomers is better on capillary columns than packed columns, these isomers can not be completely separated by gas chromatography alone (7, 13, 32). Chemical methods in conjunction with silver nitrate thin layer chromatography (argentation-TLC) to separate fatty acid methyl esters as idolactones and methoxybromomercuric adducts have been used (71,72). Argentation-TLC involves the use of a silica gel TLC plates treated with AgNO3. Ratnayake and Beare-Rogers (72) used cloroform with 0.75% ethanol to develop their plates and extracted the separated bands with hexane-chloroform (1:1 , v/v). Auxiliary methods such as Fourier transform infared spectroscopy, nuclear magnetic resonance spectroscopy, mass spectroscopy and high performance liquid chromatography have been used to identify the isomers (32, 73, 74, 75). Calvey et al. (76) analyzed hydrogenated soybean oil by supercritical fluid chromatography with Fourier Transform infared spectroscopy. This method allowed the use of one column to analyze both free fatty acids and triglycerides which cannot be done with gas chromatography, but it was not possible to obtain complete resolution of cis and trans isomers of fatty acids. High performance liquid chromatography is usually utilized to separate triglycerides prior to fatty acid analysis by other methods (77, 78, 79, 80). Christie (13) reviewed the use of supportive methods for the analysis of fatty acids. Hammond (7) explained in depth the use of thin layer chromatography and high performance liquid chromatography for the analysis of lipids. Typical polar phases for the analysis of isomers in gas chromatography are Carbowax 20M, Silar 10C, OV 275, SP 2340, CP-Sil 88 and CPS2 (7, 13, 32).

Ackman et al. (81) developed a method for the analysis of the content of eicosapentaenoic acid (EPA, 20:5n-3) and docosahexaenoic acid (DHA, C22:6n-3) in fish oil products. This method was later evaluated by a collaborative study by Joseph and Ackman (35) and was adopted first action as an AOCS-AOAC method. This method used capillary column gas

Page 224: Instrumental

207

chromatography on bonded Carbowax 20M for the analysis of fatty acids and esters of fish oils, as shown in Figure 2 (35).

0 Q c & o Q

m

�9 . .

c c c m l 0 0 - - 0 - - ~

Time (min) Figure 2. Temperature-programmed GC separation of menhaden oil fatty acid methyl esters on flexible fused silica column coated with bonded Carbowax 20M. (Reprinted with permission from reference 35.)

Quantification of EPA and DHA was determined with C23:0 as an internal standard. EPA and DHA which are omega-3 fatty acids are essential to the human diet for developing biological membranes in the retina and central nervous system (82). Polyenoic fatty acids are used to produce EPA and DHA, therefore, Ando et al. (17) focused on the separation of C16:3(n-4) and C16:4(n- 1) fatty acids using a series of steps. After the formation of methyl esters, the unsaturated fatty acids were concentrated by a urea adduct method and recovered by ether extraction. Then argentation-TLC was used to separate the methyl esters by their degree of unsaturation. Further fractionation was made on reversed phase thin layer chromatography plates to separate the methyl esters by chain length. Finally, argentation-TLC was used again to separate C16:3(n-4) from C16:4(n-1). Mass spectroscopy was used to confirm the identification of gas chromatographic peaks. Nuclear magnetic resonance (NMR) has also been utilized to analyze omega-3 fatty acids (83). 1H NMR can

Page 225: Instrumental

208

be used to determine quantities of omega-3 fatty acids, while positions of the fatty acids on the triacylglycerols can be distinguished with 13C NMR.

The analytical methods for trans-fatty acids have been developed due to the possible negative health effects associated with these fatty acids (72, 73, 84). Although trans isomers of fatty acids are not found in nature, food processing such as hydrogenation of oils produces trans isomers (82). The use of SP 2340 fused capillary columns for the separation of trans fatty acid isomers in margarine has been reported (72, 84). There were problems of overlap which could not be solved by gas chromatographic analysis alone even when 75m long capillary columns were used as shown in Figure 3 (84).

L

0 ~ Q ,m

? m

c/222 TIME (MINUTESI

Figure 3. Chromatographic trace of fatty acid methyl esters of a margarine sample analyzed on a 75m glass capillary GLC column coated with SP-2340. (Reprinted with permission from reference 84.)

Page 226: Instrumental

209

McDonald et al. (73) analyzed trans-diene isomers in hydrogenated soybean oil using packed and capillary columns with OV 275 on Chromosorb P and CP Sil88, respectively. They obtained similar results for total content of trans isomers on both columns. They also found that the capillary column provided better, but still not complete separations of the isomers and used nuclear magnetic resonance spectroscopy for identification. Fourier transform infared spectroscopy is a simple, valuable method for the determination of trans isomers (13, 75, 85, 86). A sharp peak at the 967 cm "1 area is indicative of trans double bonds. Ulberth and Haider (85) were able to determine trans unsaturation in edible fats using this method alone. Silver ion high performance liquid chromatography was utilized to isolate trans-monoenoic fatty acids which were then quantified by gas chromatography (87). This method may be more reliable than others for low levels of trans fatty acids.

The most complex samples for fatty acid analysis are processed foods. They can contain a mixture of all the above mentioned food sources. Very few papers were found that discussed the fatty acids analyses of general food products (4, 88, 89). Chloroform-methanol (2:1, v/v) was used as the lipid extracting solvent, saponification with 0.5N HCI in methanol and derivatization with boron trifluoride in methanol. Smith et al. (88) analyzed fried foods using a packed stainless steel column with 15% OV-275 on Chromosorb W support was used. Table 2 shows the fatty acid analyses of various products (88). Only cheese snacks contained fatty acids below C14:0 which were most likely due to the milk fat in the cheese. Corn and cheese snacks contained small amounts of C18:2 tt, C18:2ct and C20:1, but donuts, french fries, chicken and fish samples did not. Only fried fish contained C20:4 and C22:6 fatty acids which shows the long chain fatty acids associated with fish oils. The largest amounts of polyunsaturated fatty acids were found in corn snacks where mostly palm and sunflower oils were used. Monounsaturated fatty acid content was highest in french fries which are typically cooked in mixtures of beef fat and cottenseed oil. Cheese snacks had the highest amount of saturated fatty acids, due to the presence of cheese and milk. Significant amounts of trans unsaturated fatty acids were found in all of the samples analyzed.

Slover and Lanza (89) analyzed various food products including Crisco shortening, McDonald's fillet of fish sandwich with cheese, McDonald's Egg

Page 227: Instrumental

Table 2. Fatty Acid Composition Ranges of Lipids Extracted from Various Deep-Fat Fried Foods (Reprinted with permission from reference 88.)

@lo0 g of lipid

Fatty Acids Corn snacks (qa Cheese snacks (6) Donuts (4) French fries (6) Chidten (5) Fish (4)

c1o:o c12:o C14:O C16:O C16:lc C18:O C18:lf C18:lc C18:211 C18:2ct C18 :26 C18:3w3 C20:l C20:4 C22:6

0.1 - 0.8 9.0 - 24.8 0.2 - 0.7 2.4 - 4.2 0.0 - 16.2 17.8 - 39.0 0.0 - 1.8 1.4 - 5.5 20.7 - 51.6 0.3 - 2.4 0.2 - 0.8

Total saturated 12.8 - 28.1 Monounsaturated 18.8 - 55.9 Polyunsaturated 26.3 - 55.4 trans-Unsaturated 0.8 - 22.0

0.1 - 6.1 0.1 - 46.6 0.4 - 18.9 9.4 - 21.9 0.0 - 0.7 2.7 - 4.8 0.6 - 21.2 7.7 - 39.2 0.0 - 2.1 0.0 - 5.6 2.1 - 41.2 0.0 - 1.0 0.0 - 0.6

14.3 - 84.4 8.7 - 61.1 2.1 - 42.4 1 .o - 28.1

0.2 - 2.5 11.5 - 20.9 0.3 - 3.2 10.5 - 17.5 9.5 - 32.8 29.1 - 29.8

5.5 - 8.9 0.7 - 0.9

23.3 - 43.3 44.4 - 65.9 6.6 - 10.3 10.1 - 34.3

0.7 - 3.4 13.6 - 24.8 1.1 - 4.3 13.9 - 18.5 5.2 - 32.6 29.5 - 31.3

2.6 - 3.4 0.4 - 0.6

29.5 - 49.2 43.1 - 66.5 3.1 -4.0 6.3 - 34.1

0.3 - 0.6 0.6 - 3.2 15.9 - 20.0 13.3 - 24.7 3.2-6.2 1.1 -4.1 5.4 - 9.0 12.0 - 17.7 7.3 - 15.7 5.5 - 28.3 32.9 - 35.3 25.0 - 31.3

9.8 - 19.5 0.3 - 1.2

3.4 - 5.1 0.0 - 1.6

0.1 -1.0 0.1 -1.5

23.8 - 30.7 49.1 - 56.9 10.9 - 21.9 7.7 - 16.4

27.0 - 48.2 42.6 - 57.9 4.5 - 6.2 5.8 - 29.9

aNumber of examples analyzed.

Page 228: Instrumental

211

McMuffin and three types of baby food including beef liver, lamb broth and chicken stew. They used a 100m long glass capillary column coated with SP2340. Temperature programming gave a better separation of peaks than isothermal analysis. They were able to separate the various cis and trans isomers of 18:2w6, but not the geometric and positional isomers of C18:1. Thin layer chromatography was used to help identify the isomers. Reference and internal standards were used to quantify fatty acids in the products. Palmitic, stearic, oleic and linoleic acids were the main fatty acids in all of the analyzed foods.

Chen et al. (4) analyzed many food products and found that mayonnaise had the largest amount of palmitic, oleic and linoleic acids out of all the food products tested. Sausage contained the largest amount of stearic acid and beef stew had the lowest amounts of all fatty acids.

VI. Standard Methods for Fatty Acid Analysis

The methods recommended by the FDA (1) are those of the Association of Official Analytical Chemists (AOAC), 13th ed. (1980). No specific method was listed for the analysis of saturated fatty acids, but for the cis,cis-methylene interrupted polyunsaturated fatty acids they require the AOAC methods 28.071 to 28.074. This is an enzymatic-spectrometric method. The oil sample is saponified with KOH, then 1.0M borate buffer and water is added. The mixture is neutralized with 0.5N HCL and then enzyme solution containing lipoxidase is added. Blanks with inactivated enzyme are used to zero the spectrophotometer. The samples are measured at 234 nm as trilinolein, which is used as a standard.

Athnasios et al. (90) developed a gas chromatographic method to analyze cis,cis-methylene interrupted polyunsaturated fatty acids in fats and oils. They used a fused silica SP2340 capillary column to determine margarine fatty acids. They first saponified the separated oil with methanolic NaOH and then esterified the fatty acids with boron trifluoride. Heptane was used as the extracting solvent and a split ratio of 1:100 was used for injection into the gas chromatograph. The areas for 9,12-cis,cis-C 18:2 and 9,12,15-cis,cis,cis-C 18:3

Page 229: Instrumental

212

methyl esters were combined for total cis-polyunsaturated fatty acid content in the oil. They reported the fatty acids from C14:0 to C24:0 and obtained similar results using either a lipoxygenase method or the gas chromatography method. Although lauric acid (C12:0) is not shown, the method can be slightly modified to determine the FDA (1) defined saturated and polyunsaturated fatty acids all in one step.

The current AOAC (91) and AOCS (92) methods are the essentially the same for general analysis of fatty acids as methyl esters using gas chromatography. Both involve the use of columns packed with a polar polyester type liquid phase on acid wash, silanized diatomaceous earth. The methods employ boron trifluoride for transesterification. Sheppard (8) wrote a manual for fatty acid analysis of lipids, for the FDA. Sheppard's analytical methods are very similar to those of the AOAC and AOCS, but information for the extraction of the lipids from foods was added to complete the methods. The sample is basically homogenized and extracted with chloroform-methanol (2:1, v/v), filtered, and washed with water in a separatory funnel. The lower chloroform phase is collected, dried and the residue redissolved in petroleum ether, then the fatty acids are converted to methyl esters with boron trifluoride as in the other methods. The FSIS has recommeded both the AOAC, 15th ed., 1990, 960.39 and the Lipid Manual as references for total fat and fatty acid analysis, respectively (93).

References

1. Code of Federal Regulations, Title 21 CFR, Part 101, Food Labeling, U.S. Government Printing Office, Washington D.C. (1993).

2. J. Folch, M. Lees, and G. H. Sloane Stanley, A simple method for the isolation and purification of total lipides from animal tissues, J. Biol. Chem. 226:497 (1957).

3. E.G. Bligh and W. J. Dyer, A rapid method of total lipid extraction and purification, Candian J. of Biochem. and Phys. 37:911 (1959).

Page 230: Instrumental

213

4. I.S. Chen, C. S. J. Shen, and A. J. Sheppard, Comparison of methylene chloride and chloroform for the extraction of fats from food products, JAOCS 58:599 (1981).

5. A.J. Sheppard, W. D. Hubbard, and A. R. Prosser, Evaluation of eight extraction methods and their effects upon total fat and gas liquid chromatographic fatty acid composition analyses of food products, JAOCS 51:416 (1974).

6. W.D. Hubbard, A. J. Sheppard, D. R. Newkirk, A. R. Prosser, and T. Osgood, Comparison of various methods for the extraction of total lipids, fatty acids, cholesterol and other sterols from food products, JAOCS 54:81 (1977).

7. E.W. Hammond, Chromatography for the analysis of lipids, CRC Press, Boca Raton, Florida, 1993.

8. A.J. Sheppard, Lipid Manual, U.S. Food and Drug Administration, Wm. C. Brown Publishers, 1992.

9. W.W. Christie, Lipid Analysis (2nd ed.), Pergamon Press, Elmsford, New York, 1982.

10. F.W. Sosulski and H. M. Gadan, Variations in lipid composition among chickpea cultivars, JAOCS 65:369.

11. S.D. Senter, R. J. Horvat, and W. R. Forbus, GLC-MS analysis of fatty acids from five black walnut cultivars, J. Food Science 47:1753 (1982).

12. H. Kallio, A. Johansson, and P. Oksman, Composition and development of turnip rapeseed (brassica campestris) oil

Page 231: Instrumental

214

triacylglycerols at different stages of maturation, J. Agric. Food Chem. 39:1752 (1991).

13. W.W. Christie, Gas chromatography and lipids, The Oily Press Ltd., Ayr, Scotland, 1989.

14. H. Kallio, T. Vauhkonen, and R. R. Linko, Thin-layer silver ion chromatography and supercritical fluid chromatography of baltic herring (clupea harengus membras) triacylglycerols, J. Agric. Food Chem. 39:1573 (1991).

15. A.K.M. Aminullah Bhuiyan, W. M. N. Ratnayake, and R. G. Ackman, Stabilit of lipids and polyunsaturated fatty acids during smoking of atlantic mackeral (scomber scombrus I.), JAOCS 63:324 (1986).

16. A. Beltran and A. Moral, Changes in fatty acid composition of fresh and frozen sardine (sardina pilchardus w.) during smoking, Food Chem. 42:99 (1991 ).

17. Y. Ando, T. Ota, and T. Takagi, Japanese sardine oil as a source of 16:3(n-4) and 16:4(n-1) fatty acids, JAOCS 66:1323 (1989).

18. J. Hemavathy and J. V. Prabhakar, Lipid composition of rice (oryza sativa I.) bran, JAOCS 64:1016 (1987).

19. M.R. Sahasrabudhe, Lipid composition of oats (avena satvia I.), JAOCS 56:80 (1979).

20. M.A. Ali, M. A. Gafur, M. S. Rahman, and G. M. Ahmed, Variations in fat content and lipid class composition in ten different mango varieties, JAOCS 62:520 (1985).

Page 232: Instrumental

215

21. R. Garces and M. Mancha, One-step lipid extraction and fatty acid methyl esters preparation from fresh plant tissues, Anal. Biochem. 211:139 (1993).

22. P.C. Fourie and D. S. Basson, Application of a rapid transesterification method for indentification of individual fatty acids by gas chromatography on three different nut oils, JAOCS 67:18 (1990).

23. D.P. Schwartz and D. G. Gadjeva, A simple method for the quantitative isolation and resolution of unesterified fatty acids from fats and oils, JAOCS 65:378 (1988).

24. J. D. Craske, C D. Bannon, and L. M. Norman, Limitations of ambient temperature methods for the methanolysis of triacylglycerols in the analysis of fatty acid methyl esters with high accuracy and reliability, JAOCS 65:262 (1988).

25. R. Misir, B. Laarveld, and R. Blair, Evaluation of a rapid method for preparation of fatty acid methyl esters for analysis by gas liquid chromatography, J. Chrom. 331:141 (1985).

26. C.F. Moffat, A. S. McGill, and R. S. Anderson, The production of artifacts during preparation of fatty acid methyl esters from fish oils, food products and pathological samples, J. High Res. Chrom. 14:322 (1991).

27. N.C. Shantha, E. A. Decker, and B. Hennig, Comparison of methylation methods for the quantitation of conjugated linoleic acid isomers, J. AOAC Int. 76:644 (1993).

28. M.G. Williams and J. Macgee, Rapid determination of free fatty acids in vegetable oils by gas liquid chromatography, JAOCS 60:1507 (1983).

Page 233: Instrumental

216

29. S.W. Christopherson and R. L. Glass, Preparation of milk fat methyl esters by alcoholysis in an essentially nonalcoholic solution, J. Dairy Sci. 52:1289 (1969).

30. J. K. Ha and R. C. Lindsay, Method for the quantitative analysis of volatile free and total branched chain fatty acids in cheese and milk fat, J. Dairy Sci. 73:1988 (1990).

31. N. Gopalakrishnan, C. S. Narayanan, A G. Matthew, and C. Arumughan, Lipid composition of coconut cake oil, JAOCS 64:539 (1987).

32. H. Traitler, Recent advances in capillary gas chromatography applied to lipid analysis, Prog. Lipid Res. 26:257 (1987).

33. D.L. Auld, M. K. Heikkinen, D. A. Erickson, J. L. Sernyk, and J. E. Romero, Rapeseed mutants with reduced levels of polyunsaturated fatty acids and increased levels of oleic acid, Crop Sci. 32:657 (1992).

34. W.E. May and D. J. Hume, An automated gas liquid chromatographic method of measuring free fatty acids in canola, JAOCS 70:229 (1993).

35. J. D. Joseph and R. G. Ackman, Capillary column gas chromatographic method for analysis of encapsulated fish oil ethyl esters: collaborative study, J. AOAC Int. 75:488 (1992).

36. R.G. Ackman, Capillary GLC has finally 'arrived', JAOCS 66:293 (1989).

37. I. Norman, H. Traitler, and J. Aeschlimann, A fatty acid methyl ester (FAMES) analyzer, J. High Res. Chrom. 12:308 (1989).

38. J.K. Daun, P. B. Mazur, and C. J. Marek, Use of gas liquid chromatography for monitoring the fatty acid composition of canadian rapeseed, JAOCS 60:1751 (1983).

Page 234: Instrumental

217

39. M.L. Dahmer, P. D. Fleming, G. B. Collins, and D. F. Hildebrand, A rapid screening technique for determining the lipid composition of soybean seeds, JAOCS 66:543 (1989).

40. J.L. Iverson and A. J. Sheppard, Detection of adulteration in cow, goat, and sheep cheeses utilizing gas liquid chromatographic fatty acid data, J. Dairy Sci. 72:1707 (1989).

41. L.L. Wang, A. C. Peng, and A. Proctor, Varietal differences in lipid content and fatty acid composition of highbush blueberries, JAOCS 67:499 (1990).

42. J. Hemavathy and J. V. Prabhakar, Lipid composition of calophyllum inophyllum kernel, JAOCS 67:955 (1990).

43. J. Hemavathy, Lipid composition of murraya koenigii seed, JAOCS 68:651 (1991).

44. D. Firestone and W. Horwitz, IUPAC gas chromatographic method for determination of fatty acid composition: collaborative study, JAOAC 62:709 (1979).

45. K. Eder, A. M. Reichlmayr-Lair, and M. Kirchgessner, Gas chromatographic analysis of fatty acid methyl esters: avoiding discrimination by programmed temperature vaporizing injection, J. Chrom. 588:265 (1991).

46. F. Ulberth and M. Henninger, On column injection of fatty acid methyl esters on to polar capillary columns without distortion of early eluting peaks, J. High Res. Chrom. 15:54 (1992).

47. J. D. Craske, Separation of instrumental and chemical errors in the analysis of oils by gas chromatography- a collaborative evaluation, JAOCS 70:325 (1993).

Page 235: Instrumental

218

48. J.L. Iverson and A. J. Sheppard, Programmed temperature gas chromatographic analysis of esters of fatty acids, 13:505 (1975).

49. B. Freedman, W. F. Kwolek, and E. H. Pryde, Quantitation in the analysis of transesterified soybean oil by capillary gas chromatography, JAOCS 63:1370 (1986).

50. J.D. Craske and C. D. Bannon, Gas liquid chromatography analysis of the fatty acid composition of fats and oils: a total system for high accuracy, JAOCS 64:1413 (1987).

51. C.D. Bannon, J. D. Craske, and A. E. Hilliker, Analysis of fatty acid methyl esters with high accuracy and reliability. V. Validation of the theoretical relative response factors of unsaturated esters in the flame ionization detector, JAOCS 63:105 (1986).

52. U. Olsson, P. Kaufmann, and B. G. Herslof, Multivariate optimization of a gas liquid chromatographic analysis of fatty acid methyl esters of blackcurrant seed oil, J. Chrom. 505:385 (1990).

53. J. D. Craske and C. D. Bannon, Letter to the editor, JAOCS 65:11 (1988).

54. J. Krupcik and P. Bohov, Use of equivalent chain lengths for the characterization of fatty acid methyl esters separated by linear temperature programmed gas chromatography, J. Chrom. 346:33 (1985).

55. C.A. Wulff, A. H. Duthie, and S. Wulff, Functional analysis of gas chromatographic data for C-4 through C-18:2 acids, JAOCS 1:34 (1980).

56. I.W. Choi and I. J. Jeon, Patterns of fatty acids released from milk fat by residual lipase during storage of ultra-high temperature processed milk, J. Dairy Sci. 76:78 (1993).

Page 236: Instrumental

219

57. L. Ceccon, Quantitative determination of free volatile fatty acids from dairy products on a Nukol capillary column, J. Chrom. 519:369 (1990).

58. A.H. Duthie, S. Wulff, and R. L. Clark, Formic acid trap for GC analysis of fatty acids and their salts, J. Chrom. Sci. 21:185 (1983).

59. Research Note: Device for saturating gas chromatographic carrier gas with formic acid for free fatty acid and barbituate analyses, J. Chrom. Sci. 18:273 (1980).

60. W.N. Sawaya, T. Saeed, M. Mameesh, E. EI-Rayes, A. Husain, S. Ali and H. A. Rahman, Detection of pork in processed meat: Experimental comparison of methodology, Food Chem. 37:201 (1990).

61. E.M. Gaydou, M. C. latrides, R. Ramananarivo, J. Artaud, and G. Peiffer, Pattern recognition analysis of fatty acids. Application to beef fat tissue classification, J. Agric. Food Chem. 32:651 (1984).

62. M.B. Solomon, G. P. Lynch, and D. S. Lough, Influence of dietary palm oil supplementation on serum lipid metabolites, carcass characteristics, and lipid composition of carcuss tissues of growing ram and ewe lambs, J. Anim. Sci. 70:2746 (1992).

63. M.B. Solomon, G. P. Lynch, E. Paroczay, and S. Norton, Influence of rapeseed meal, whole rapeseed, and soybean meal on fatty acid composition and cholesterol content of muscle and adipose tissue from ram lambs, J. Amin. Sci. 69:4055 (1991).

64. A.J. Sinclair, W. J. Slattery, and K. O'Dea, The analysis of polyunsaturated fatty acids in meat by capillary gas liquid chromatography, J. Sci. Food Agric. 33:771 (1982).

Page 237: Instrumental

220

65. E.M. Gaydou, R. Raonizafinimanana, and J. P. Bianchini, Quantitative analysis of fatty acids and sterols in malagasy rice bran oils, JAOCS 4:141 (~98o).

66. S.D. Senter and R. J. Horvat, Lipid constituents of black walnut kernels, J. Food Sci. 44:266 (1979).

67. M. Demirbuker, L. G. Blomberg, N. U. Olsson, M. Bergqvist, B. G. Herslof, and F. A. Jacobs, Characterization of triacylglycerols in the seeds of aquilegia vulgaris by chromatographic and mass spectrometric methods, Lipids 27:436 (1992).

68. L.S. Conte, O. Leoni, S. Palmieri, P. Capella, and G. Lercker, Half-seed analysis: Rapid chromatographic determination of the main fatty acids of sunflower seed, Plant Breeding 102:158 (1989).

69. W. E. Artz and R. M. Sauer, An improved micro-extraction cell for supercritical fluid ectraction and chromatography of fatty acids, JOACS, 69:309 (1992).

70. N. M. A. Moneam and T. Ghoneim, Gas chromatographic analysis of total fatty acids extracted from schinus terebenthifolious berries, J. Chrom. 361:391 (1986).

71. N. Vo Gaiday, A. B. Imbs, D. V. Kuklev, and N. A. Latyshev, Separation of natural polyunsaturated fatty acids by means of iodolactonization, JAOCS 68:230 (1991 ).

72. W. M. N. Ratnayake and J. L. Beare-Rogers, Problems of analyzing C18 cis- and trans-fatty acids of margarine on the SP-2340 capillary column, J. Chrom. Sci. 28:633 (1990).

73. R.E. McDonald, D. J. Armstrong, and G. P. Kreishman, Identification of trans-diene isomers in hydrogenated soybean oil by gas chromatography,

Page 238: Instrumental

221

silver nitrate thin layer chromatography, and 13 C NMR spectroscopy, J. Agric. Food Chem. 37:637 (1989).

74. M.M. Mossoba, R. E. McDonald, D. J. Armstrong, and S. W. Page, Identification of minor C18 triene and conjugated diene isomers in hydrogenated soybean oil and margarine by GC-MI-FT-IR spectroscopy J. Chrom. Sci. 29:324 (1991).

75. R. Wood and T. Lee, High performance liquid chromatography of fatty acids: quantitative analysis of saturated, monoenoic, polyenoic, and geometrical isomers, J. Chrom. 254:237 (1983).

76. E. M. Calvey, R. E. McDonald, S. W. Page, M. M. Mossaba and L. T. Taylor, Evaluation of SFC/FT-IR for examination of hydrogenated soybean oil, J. Agric. Food Chem. 39:542 (1991).

77. Y. Ando and T. Takagi, Micro method for stereospecific analysis of triacyl- sn-glycerols by chiral phase high performance liquid chromatography, JAOCS 70:1047 (1993).

78. P. Laakso and H. Kallio, Triacylglycerols of winter butterfat containing configurational isomers of monoenoic fatty acyl residues. I. Disaturated monoenoic triacylglycerols, JAOCS 70:1161 (1993).

79. P. Laakso and H. Kallio, Triacylglycerols of winter butterfat containing configurational isomers of monoenoic fatty acyl residues. I1. Saturated dimonoenoic triacylglycerols, JAOCS 70:1173 (1993).

80. A. Kemppinen and P. Kalo, Fractionation of the triacylglycerols of lipase- modified butter oil, JAOCS 70:1203 (1993).

81. R.G. Ackman, W. M. N. Ratnayake, and E. J. Macpherson, EPA and DHA contents of encapsulated fish oil products, JAOCS 66:1162 (1989).

Page 239: Instrumental

222

82. Diet and health, National Academy Press, Washington, D. C., 1989.

83. M. Aursand, J. R. Rainuzzo and H. Grasdalen, Quantitative high resolution 13C and 1H nuclear magnetic resonance of ~3 fatty acids from white muscle of atlantic salmon (Salmo salar), JAOCS 70:971 (1993).

84. J. Sampugna, L. A. Pallansch, M. G. Enig, and M. Keeney, Rapid analysis of trans fatty acids on SP-2340 glass capillary columns, J. Chrom. 249:245 (1982).

85. F. Ulberth and H. J. Haider, Determination of low level unsaturation in fats by Fourier transform infared spectroscopy, J. Food Sci. 57:1444 (1992).

86. M. M. Mossoba, R. E. McDonald and A. R. Prosser, Gas chromatographic/matrix isolation/Fourier transform infared spectroscopic determination of trans-monounsaturated and saturated fatty acid methyl esters in partially hydrogenated menhaden oil, J. Agric. Food Chem. 41:1998 (1993).

87. T.G. Toschi, P. Capella, C. Holt and W. W. Christie, A comparison of silver ion HPLC plus GC with Fourier transform IR spectroscopy for the determination of trans double bonds in unsaturated fatty acids, J. Sci. Food Agric. 61:261 (1993).

88. L.M. Smith, A. J. Clifford, R. K. Creveling, and C. L. Hamblin, Lipid content and fatty acid profiles of various deep-fat fried foods, JAOCS 62:996 (1985).

89. H.T. Slover and E. Lanza, Quantitative analysis of food fatty acids by capillary gas chromatography, JAOCS, 56:933 (1979).

90. A.K. Athnasios, E. J. Healy, A. F. Gross, and G. J. Templeman, Determination of cis,cis-methylene interrupted polyunsaturated fatty acids in fats and oils by capillary gas chromatography, JAOAC 69:65 (1986).

Page 240: Instrumental

223

91. Association of Official Analytical Chemists, Official Methods of Analysis, Section 963.22 (1990).

92. American Oil Chemists Society, AOCS Official Method Ce 1-62, Vol. 1 (1990).

93. Federal Register, Rules and Regulations, 58:663 (1993).

Page 241: Instrumental

This Page Intentionally Left Blank

Page 242: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 225

Isolation of volatile flavor compounds from peanut butter using purge-and-trap techniques

Terri Drumm Boylston "b and Bryan T. Vinyard'

'Southern Regional Research Center, U.S. Department of Agriculture, Agricultural Research Service, P.O. Box 19687, 1100 Robert E. Lee Boulevard, New Orleans, LA 70179

~Present Address: Department of Food Science and Human Nutrition, Washington State University, Pullman, WA 99164-6376

INTRODUCTION

Roasted peanut flavor is composed of a complex blend of heterocyclic and other volatile compounds formed during roasting. Thermal degradation reactions, including Maillard reactions between carbohydrates, free amino acids and proteins, and lipid precursors in the raw peanuts, contribute to the formation of desirable, roasted peanut flavor [ 1-2]. Lipid oxidation reactions during storage or processing of the raw or roasted peanuts contribute to the formation of numerous carbonyl compounds and the development of undesirable cardboardy or painty flavors [3-5]. In recent years, the focus of flavor research has been on the effects of processing and storage on the relative content of volatile flavor compounds and the improvement of flavor quality [6].

Several hundred compounds have been isolated and identified in roasted peanut flavor using solvent [7], distillation [8], vacuum degassing techniques [9-10], headspace analysis methods with cryogenic [11] or adsorbent [ 12-13] trapping, and direct gas chromatography methods [14-15]. With the exception of the direct gas chromatography method, these methods use extremely large sample sizes (350 g to 70 kg) to identify the compounds present at extremely low concentrations. Although the direct gas chromatography method uses a small sample size (0.2 to 0.3 g), the use of packed column chromatography for the separation of the volatile compounds does not provide the resolution and sensitivity needed for a comprehensive study of the volatile compounds.

Headspace analysis techniques isolate the volatile flavor compounds in equilibrium with the food. The volatile flavor compounds in the isolate are proportional to the contents of the volatile flavor compounds in the headspace. These techniques do not result in a total or exhaustive extraction of all volatile flavor compounds present, but rather result in an isolate which is representative of the aroma perceived by the sense of smell [ 16-17]. The application of concentration techniques, such as nitrogen purging, application of vacuum, cryogenic trapping, and adsorbent trapping, to enhance the recovery of the volatile flavor compounds during headspace analysis has been discussed extensively in the literature [ 12,16-26].

Numerous adsorbents are available for the collection of volatile compounds in the headspace of foods. The characteristics of these adsorbents and the advantages and limitations of their use vary widely [27]. Activated carbon was one of the first adsorbents used for the isolation of volatile compounds. This adsorbent has a large adsorption capacity; however, there are problems related to inconsistencies in quality and impurities in the

Page 243: Instrumental

226

charcoal. Tenax-GC has been used widely for the isolation of volatile compounds from foods because it shows excellent recovery of adsorbed compounds, good thermal stability, and low affinity for water, although it is limited by its lower adsorption capacity [20,27]. Carbopack B/Carbosieve S-III have been suggested as replacements for the currently used adsorbents for environmental research. The combination of these two adsorbents provides an effective system for trapping and desorbing a wide range ofvolatiles [28].

Flavor research frequently entails a comprehensive approach, which involves sensory analysis and the determination of chemical composition in addition to volatile flavor analysis. In some cases, this approach reduces the amount of sample available for the analyses. Therefore, the objective of this study is to develop a reproducible, quantitative headspace analysis method for the isolation of volatile flavor compounds from roasted peanut butter. Three purge temperatures, 50~ 70~ and 90~ three purge times, 1 hr, 2 hr, and 4 hr; and two adsorbents, Carbopack B/Carbosieve S-III (CP/CS) and Tenax-GC (Tenax) will be compared. Maximum recovery of the volatile flavor compounds allows the detection of the compounds present in very low quantities. This method will be applied to future research in which the effects of postharvest and processing treatments on the relative content of the volatile flavor compounds will be determined.

MATERIALS AND METHODS

Peanuts (Arachis hypogea L. cv. Florunner) were grown at the Coastal Experimental Station in Tifton, GA during the summers of 1988 and 1989. Medium and jumbo peanuts (>7.15 nun, diameter), of good quality were roasted at 163~ at an air flow of 0.01 cu. fk/min for 11 and 11.5 min, respectively, in a surface combustion roaster (Midland-Ross Corp., Toledo, OH), and combined in equal quantities. Peanut butters were prepared as described by Sanders et al. [29]. The finished peanut butters had an L value (Hunter Lab Colorimeter) of 49.0.

Isolation of Volatile Flavor Compounds The adsorbents: (1) Tenax-GC (300 mg, 60-80 mesh, Teklab, Inc., Baton Rouge, LA)

or (2) Carbopack B graphitized carbon black (400 rag, 60/80 mesh, Supelco, Inc., Bellefonte, PA) and Carbosieve S-III carbon molecular sieve (200 mg, 60/80 mesh, Supelco, Inc.) were packed into borosilicate glass tubes (84 mm long, 9 mm od, 1 mm wall) between two plugs of silanized glass wool. The traps were rinsed with 10 ml methanol and conditioned in a stream of nitrogen (15 ml/min) at 250~ for 2 hr.

Peanut butter (50 g) was uniformly and completely coated onto the walls of a 300-ml, 3-neck, round-bottom flask using a long-handled spatula. Tetradecane (internal standard, 100 lag) was added to the surface of the sample prior to purging. The peanut butter flowed to the bottom of the flask during the isolations, regardless of purge temperature. The center neck of the flask contained the trap, which was held in place using a Midi-Ace threaded adapter (Ace Glass, Inc., Vineland, NJ) with a 5 psi vacuum applied to the system through the trap. The samples were purged with nitrogen (50 ml/min) through a nitrogen inlet tube placed in the side neck of the flask. The third neck of the flask was stoppered. Purge (water bath)

Page 244: Instrumental

227

temperatures were set at 50 ~ 70 ~ and 90~ and volatiles were collected for 1, 2, or 4 hr. Prior to elution of the volatiles from the trap, pentadecane (quantification standard, 20 ~tg) was placed on the top of the adsorbent. The volatiles were eluted from the trap with 15 ml hexane, using positive pressure, and concentrated to 100 ~tl under a stream of nitrogen.

Identification and Quantification of Volatile Flavor Compounds The volatile flavor compounds were separated on a cross-linked, 5% phenylmethyl

silicone fused silica capillary column (HP-5, 50 rn, 0.32 mm od, 0.52 ~t film thickness, Hewlett-Packard, Avondale, PA) installed in a gas chromatograph equipped with a flame ionization detector (Model 5890A, Hewlett-Packard). The GC oven temperature was initially held at 35~ for 15 min, then increased at a rate of 2~ to a final temperature of 250~ and held for 45 min. Injector and detector temperatures were set at 200~ and 250~ respectively. The extracts (2.5 ml) were injected using a split injection, with a column flow rate of 1.1 ml/min, purge flow rate of 2.0 ml/min, split vent flow rate of 15.0 ml/min, and split ratio of 14:1. Area counts vs nanogram quantities (20-500 ng) were plotted for the standards, tetradecane and pentadecane. Peak areas of all volatile compounds were converted to nanogram amounts by using the standard curves developed for the quantification standard, pentadecane. Relative quantification of the volatile flavor compounds in the peanut butter was based on the recovery of pentadecane.

Identification of the compounds was confirmed through the comparison of retention times of standards and Samples, and mass spectrometry. A gas chromatograph-quadrupole mass spectrometer (Model 4500, Finnigan-MAT, Cincinnati, OH) interfaced with an Incos data system was used to confirm the identity of the volatile compounds. GC conditions were the same as for the chromatographic analysis. The conditions for the mass spectrometer were set as follows: ionizing voltage, 70 eV; emission current, 0.3 mA; electron multiplier voltage, 1800 kV; ion source temperature, 150~ ionization chamber pressure, 6.0 x 10 "~ atm; and scan range 33 to 250 m/z in 0.95 sec with a 0.05 sec hold. Identification of mass spectra was based on matches with the library within the Incos data system and mass spectral data published in the literature [8, 30-36].

Statistical Analysis The experimental design consisted of a 3-way factorial in a completely randomized

design structure, with adsorbent (Tenax-GC and Carbopack B/Carbosieve S-III), purge temperature (50 ~ 70 ~ 90~ and purge time (1, 2, 4 hr) as the main factors. Two crop years (1988, 1989) served as the replications for the experiment; all treatment and replication combinations were repeated 3 times. For each purge temperature, purge time and crop year combination, the two adsorbents were paired.

The purge isolation conditions which resulted in the maximum recovery of total volatile flavor compounds from peanut butter were determined based on the recoveries of the 48 most abundant compounds isolated using frequency tables and multivariate statistical techniques. For each year and adsorbent combination, the mean recoveries for the 48 volatile flavor compounds were ranked from highest (rank =- 1) to lowest (rank=-9) with respect to the 9 purge temperature and time combinations. The data for each year and adsorbent were pooled to form one table. For each rank, the number of volatile compounds with that given rank

Page 245: Instrumental

228

were determined. Based on this table overall rank of recovery for each purge time and temperature combination were determined (PROC FREQ) [37].

Paired t-tests on adsorbent differences for each volatile compound from both crop years were performed to compare the recovery of the volatile flavor compounds. The t-tests were performed on 3 sets of recovery data determined by the rank analysis: (1) the purge temperature-time combinations for the maximum recovery (Rank=l), (2) the purge temperature-time combinations for the three highest overall recoveries, and (3) the purge temperature-time combination for the maximum overall recovery.

Principal component analyses (PROC PRINCOMP) and cluster analyses (PROC VARCLUS) were performed on the data to identify a necessary and sufficient subset of the 48 variables that, when maximized, would also maximize the recovery of all 48 variables [37]. The multivariate analyses were performed on the subsets of data for each year and adsorbent combination, with the data from all purge temperatures and purge times included within the four subsets. The number of clusters allowed to form in the multivariate analysis was specified as the number of principal components explaining a non-zero proportion of the overall variation in the data. These analyses objectively identified and selected a set of 'near' linearly independent variables or a key variable set. From these multivariate statistical techniques, a subset of volatile flavor compounds was selected that represented the response of all 48 volatile flavor compounds. Analysis of variance (PROC GLM) was used to determine the effects of adsorbent and purge temperature and time on the recovery of the volatile flavor compounds selected to make up the key variable set as representative of the initial 48 volatile flavor compounds [37].

RESULTS AND DISCUSSION

Representative, reproducible chromatograms were obtained using purge-and-trap techniques for the isolation of volatile flavor compounds from peanut butter. Pyrazines, furans, sulfur compounds, aldehydes, ketones, alcohols, and other volatile compounds identified in the peanut butters using this technique are listed in Table 1. The compounds positively identified in this research have been identified previously in roasted peanuts [38 and references within].

Isolation of Volatile Flavor Compounds Headspace analysis results in the isolation of a representative sample of the volatile

flavor compounds above, and in equilibrium with, the food [ 16-17]. Although an exhaustive extraction of the volatile flavor compounds is not possible using headspace analysis techniques, through controlling the conditions of the isolation, recovery of the volatile flavor compounds can be maximized. Artifact formation during the isolation was minimized by the selection of a purge temperature below 132~ the critical minimum temperature for flavor formation in peanuts via Maillard reactions [39], and the continuous nitrogen purge of the samples to minimize oxidative degradation.

Page 246: Instrumental

229

Table 1 Volatile flavor compounds identified in peanut butter using purge-and-trap headspace analysis', Kovats Kovats

RI Compound RI Compound Pyrazines: 828 Methylpyrazine 909 2,5-Dimethylpyrazine b 910 2,6-Dimethylpyrazine b 917 2,3-Dimethylpyrazine b 914 Ethylpyrazine b 1001 Trimethylpyrazine b 997 2-Ethyl-6-methylpyrazine b 1000 2-Ethyl-5-methylpyrazine b 1003 2-Ethyl-3-methylpyrazine b 1019 2-Methyl-6-vinylpyrazine b (t) 1022 2-Methyl-5-vinylpyrazine b (t) 1080 3-Ethyl-2,5-dimethylpyrazine b 1085 2-Ethyl-3,5-dimethylpyrazine b 1090 5-Ethyl-2,3-dimethylpyrazine 1083 2,6-Diethylpyrazine b (t) 1087 2, 5-Diethylpyrazineb (t) 1101 Dimethyl-2-vinylpyrazine b (t) 1157 2,3-Diethyl-5-methylpyrazine b 1159 3,5-Diethyl-2-methylpyrazine b 1162 2,5-Dimethyl-3-propylpyrazine 1190 2-Methyl-5-(1-propenyl)pyrazine 1104 6,7-Dihydro-5H-

cyclopentapyrazine (t) 1188 6,7-Dihydro-2-methyl-5H-

cyclopentapyrazine (t) 1225 6,7-dihydro-2, 5-dimethyl-5H-

cyclopentapyrazine (t)

Furans: 965 5-Methyl-2-furfural b 978 2-Acetyl-3-hydroxy~ran (t) 991 2-Pentylfuran 1220 2-Vinylbenzofuran

Aldehydes: 809 Hexanal b 858 2-Hexenal b 902 Heptanal b 958 2-Heptenal b 1004 Octanal 1012 2,4-Heptadienal 1059 2-OctenaJ b 1105 Nonanal b 1161 2-Nonenal 1218 2,4-Nonadienal 1208 Decanal 1260 2-Decenal 1296 t, c-2,4-Decadienal 1320 t, t-2,4-Decadienal b 962 Benzaldehyde b 1047 Phenylacetaldehyde b

Ketones: 800 2-Hexanone 795 3-Hexanone 891 2-Heptanone 993 2-Octanone b 984 2,3-Octanedione (t) 1043 3-Octen-2-one 1096 3,5-Octadien-2-one (t) 1094 2-Nonanone 1141 3-Nonene-2-one b 1191 2-Decanone 1034 2-Hydroxy-3-methyl-2-

cyclopentene-l-one (t)

Page 247: Instrumental

230

.Table 1 (cont.) Kovats

RI Compound Kovats

ILl Compound

Sulfur Compounds: 761 Dimethyldisulflde 972 Dimethyltrisulfide b 790 3-Methylthiophene 795 2-Methylthiophene 1023 2-Acetylthiazole b 1236 Benzothiazole 1271 5-(2-Hydroxyethyl)-4-

methylthiazole (t)

Other Heterocyclic Compounds: 976 Pyranone (t) 1058 Trimethyl-2H-pyranoneb (t) 1112 3-Hydroxy-2-methyl-4H-

pyranone (t) 1149 2,3-Dihydro-3,5-dihydroxy-6-

methyl-4H-pyran-4-one (t) 998 3-Methoxypyridine (t) 1017 2-Vinylpyridine (t) 1036 2-Acetylpyridine b 1013 1H-Pyrrole-2-carboxaldehyde (t) 1067 2-Acetylpyrrole b (t) 1182 1-(2-Furanylmethyl)-1H-pyrrole (t) 1238 3-Ethyl-4-methyl-lH-pyrrole-2,5-dione (t)

Alcohols: 874 1-Hexanol 811 2-Hexanol 806 3 -Hexanol 872 2-Hexen- 1-ol 972 1-Heptanol 1098 1,2-Heptanediol (t) 1072 1-Octanol 981 1-Octen-3-ol b 1173 1-Nonanol 1269 1-Decanol

Miscellaneous Compounds: 1030 Limonene b 1037 Benzenemethanol b 1118 Benzeneethanol (t) 1221 2-Phenoxyethanol (t) 1222 Vinylphenol b 1265 2-Phenyl-2-butenal (t) 1177 Naphthalene 1277 Methylnapthalene

' Identification of volatile flavor compounds based on comparison of mass spectrum and retention times of authentic standards except where labeled tentative (t), where no authentic sample was available. b Identified volatile flavor compounds included in statistical analyses to determine the optimum conditions for purge-and-trap isolation. (Ten compounds were included in the statistical analyses, but not identified.)

Page 248: Instrumental

231

Internal standards were added to the peanut butter sample prior to purging (tetradecane) and to the top of the trap prior to solvent elution (pentadecane). The recovery of the tetradecane, as well as the volatile compounds in the sample, is dependent on purge temperature and purge time. Addition of an internal standard with the sample to determine the conditions necessary for maximum recovery of the volatile flavor compounds would not be valid. Therefore, the internal standard added to the traps following purging and prior to solvent elution, was used as the quantification standard. In the application of this method, the addition of an internal standard to the sample prior to purging would be recommended.

Solvent elution results in lower recoveries of volatile compounds and the loss of highly volatile compounds due to evaporation during concentration [27]. However, thermal desorption contributes to potential artifact formation [21 ]. Therefore, the volatile compounds were desorbed from the adsorbent by solvent elution, rather than by thermal desorption to minimize thermal degradation of the volatile compounds.

Statistical Analysis The major objective of this study was to determine the conditions for the maximum

recovery of volatile flavor compounds from peanut butter. Forty-eight of the major volatile flavor compounds were included in the statistical analyses to determine the effects of purge temperature, purge time, and adsorbent on their recovery. Of these, 38 volatile flavor compounds were positively or tentatively identified. Direct comparison of each of the treatment effects was complicated by the number of compounds of interest and the variable effects of purge conditions on the recovery of the compound. Therefore, two alternative statistical methods, frequency table analyses of the recovery ranks [40] and multivariate statistical techniques [41] were used to determine the conditions for maximum recovery of volatile flavor compounds from peanut butter.

Multivariate statistical techniques [37, 40-41] were used to select a smaller set of compounds which can be used to determine the effects of the three isolation factors: purge temperature, purge time, and adsorbent on the recovery of the volatile flavor compounds. Principal component (PCA) and cluster analyses (CA) divided the 48 variables into groups called clusters based on the similarities and differences between the values observed for them. The response of the compounds to the different purge temperature and time combinations within each cluster were highly correlated with the other volatile compounds identified within that particular cluster. The variable showing the greatest correlation with its cluster was chosen to best represent the properties of all variables contained within that cluster.

The initial solution obtained through PCA and CA resulted in the selection of 16 and 24 variables for the Tenax and CP/CS adsorbents, respectively. The principal component and cluster analyses were then repeated on this selected data set, for each adsorbent and year combination, to determine if further reduction in the number of variables could occur. From this analysis, a reduced data set containing 6 dependent variables for each adsorbent x year combination, resulting in 12 different volatile flavor compounds, were selected (Table 2). Vinylphenol, 2,5-dimethylpyrazine, and trimethylpyrazine were identified as key components for the first three clusters for each adsorbent and crop year combination. Other compounds identified within the key variable set include acetylpyrrole, hexanal, phenylacetaldehyde, 3-

Page 249: Instrumental

232

ethyl-2, 5-dimethylpyrazine, and benzaldehyde.

pyranone, 2- ethyldimethylpyrazine, ethylmethylpyrazine,

Table 2 Volatile flavor compounds in peanut butter identified through multivariate statistical techniques as representative of all volatile flavor compounds with respect to purge condition

Cluster 1988 1989

Tenax-GC 1 Vinylphenol Vinylphenol 2 2, 5-Dimethylpyrazine 2, 5-Dimethylpyrazine 3 Trimethylpyrazine Trimethylpyrazine 4 Acetylpyrrole Phenylacetaldehyde 5 Hexanal Unknown-MW 155 6 Phenylacetaldehyde Acetylpyrrole

CP/CS 1 Vinylphenol Vinylphenol 2 2, 5-Dimethylpyrazine 2, 5-Dimethylpyrazine 3 Trimethylpyrazine 3 -Et hyl-2, 5- dimethylpyrazine 4 Dimethylvinylpyrazine Pyranone 5 2-Ethyldimethylpyrazine Ethylmethylpyrazine 6 Benzaldehyde Hexanal

The factors and interactions found to be significant by the analysis of variance for these selected volatile flavor compounds are summarized in Table 3. Interactions between purge temperature, purge time, and/or adsorbent were significant (P<0.05) for trimethylpyrazine, 3-ethyl-2,5-dimethylpyrazine, dimethylvinylpyrazine, and 2,3-dihydro-3,5- dihydroxy-6-methyl-4Hpyran-4-one. Thus, for these compounds, the factors do not act independently and means cannot be pooled.

The recovery of individual flavor compounds is influenced by isolation conditions. The effect of purge temperature, purge time, and adsorbent on the recovery of volatile flavor compounds will be discussed in further detail as evaluated through rank and multivariate statistical analyses.

Effects of Purge Temperature and Purge Time Recovery of the volatile flavor compounds isolated in the purge-and-trap isolation

from peanut butter increases with an increase in purge temperature and purge time. Results of both statistical analysis techniques indicated that maximum recovery occurred most frequently at a purge temperature and time of 90~ for 4 hr, followed by purge conditions of 90~ for 2 hr and 70~ for 4 hr for both the Tenax and CP/CS adsorbents (Table 4). These purge conditions resulted in isolates with characteristic roasted peanut flavor, as determined by an informal aroma evaluation of the isolates by researchers who have experience in peanut flavor.

Page 250: Instrumental

233

A comparison of the contents of the volatile flavor compounds, representative of the clusters identified through multivariate statistical analysis, as a function of purge temperature and purge time are shown in Tables 5 and 6.

Table 3 Results of analyses of variance on the recovery of key volatile flavor compounds identified through multivariate statistical techniques

Compound Significant Effects (P<0.05)

Vinylphenol 2,5-Dimethylpyrazine 3-Ethyl-2,5-dimethylpyrazine Trimethylpyrazine 3-Ethyl-2,5-dimethylpyrazine Acetylpyrrole Phenylacetaldehyde Dimethylvinylpyrazine 2,3-Dihydro-3,5-dihydroxy-6-

methyl-4Hpyran-4-one Hexanal Unknown-MW 155 2-Ethyl- 5-methylpyrazine Benzaldehyde

Trap Trap Trap Trap Trap

Temp Time Temp Time Temp Temp Time Temp Time Temp Time Temp Temp Time Temp Time

Temp Time Temp Time Temp Time

Trap*Temp*Time Trap*Temp*Time

Trap*Time Temp*Time

The observed relationship between purge temperature and purge time and the recovery of volatile flavor compounds would be expected due to the shift in equilibrium of the volatiles between the food and the headspace above the food during the isolation. The volatility of these compounds influenced the degree to which the purge temperature and time influenced their recovery, with the more volatile compounds affected by purge conditions to a lesser degree.

Breakthrough or partial loss of some highly volatile compounds is a potential problem during headspace analysis with trapping on Tenax. However, these highly volatile compounds usually do not have a significant impact on flavor of roasted peanuts [ 12]. In this study, the recovery of the volatile flavor compounds was greatest as purge temperature or purge time increased. Thus, it was assumed that no significant loss of volatile flavor compounds occurred during the isolation.

The purge temperature and time combination which resulted in the greatest recovery of volatile flavor compounds is at the maximum temperatures and times chosen for this experiment. These conditions also contributed to the lowest mean coefficient of variability, which is important in determining the effects of postharvest and storage conditions on the relative contents of volatile flavor compounds. Further increases in the purge temperature and time will more than likely increase the recovery of volatile flavor compounds through

Page 251: Instrumental

234

enhancement of the volatilization of these compounds into the headspace. However, these increases may also contribute to a greater potential for artifact formation during the isolation.

Table 4 Summary of frequency table analyses of the recovery ranks as a function of purge temperature and purge time"

Purge Conditions

Rank Temperature (~ Time (hr) 1 90 4 2 90 2 3 70 4 4 90 1 5 70 2 6 50 4 7 70 1 8 50 2 9 50 1

Data for 3 replications and two traps have been pooled. Rank = 1 indicates highest recovery of each volatile compound. Results of rank analysis were verified with a Chi- square goodness of fit test (Conover, 1980).

Effects of Adsorbent Tenax-GC has been used widely for the isolation of volatile compounds from foods

because it shows excellent recovery of adsorbed compounds, good thermal stability, and low affinity for water, although it is limited by its lower adsorption capacity [20,27]. Carbopack B/Carbosieve S-III have been suggested as replacements for the currently used adsorbents for environmental research. The combination of these two adsorbents provides an effective system for trapping and desorbing a wide range of volatiles [28].

Recovery of the volatile compounds was greater when Tenax was used as the adsorbent in comparison to CP/CS, as shown by the rank analysis (Table 7) and analysis of variance of the compounds selected through multivariate statistical techniques (Tables 6 and 8). This difference in recovery of the volatile flavor compounds may be attributed to differences in the affinity of the polymer adsorbents for the specific volatile flavor compounds or the release of the compounds from the respective polymers with solvent elution. Although Mosesman et al. [28] noted a higher recovery of volatile compounds using Carbopack and Carbosieve adsorbents, these researchers were applying these methods to the isolation of

Page 252: Instrumental

Table 5 Influence of purge temperature and time on the recovery of key volatile flavor compounds identified through multivariate statistical techniques."

Content (ng/g) Temp. (T) 50 70 90 Mean Time (hr) VinvlDhenol: S.E. 141

1 47 188 60 1 279" 2 87 299 762 3 82" 4 117 556 1515 729'

Mean 83' 34Sb 959' 2.5-DimethvlDmzine: S.E. 29

1 153 23 3 283 223' 2 180 243 256 227' 4 214 227 276 239'

Mean 1 82b 23 5'b 272' Acetvlpp-ole: S.E. 5

1 2 7 22 1 0" 2 4 11 31 15" 4 5 19 59 28'

Mean 3b 1 2b 3 8' Phenvlacetaldehvde: S.E. 22

1 28 2 40 4 43

51 68 82

53 44' 58 55' 42 5 6'

Mean 37b 67' 5 1'

1 2b - Sb 1 3b

4 5b 1 Ob 46'

2.3-Dihvdro-3.5-dihvdroxv-6-methvl-4H~vran-4-one*: S.E. 9

2 4b 6b Sb

Page 253: Instrumental

N W Q\

Hexanal: S.E. 5 1 15 24 21 20d 2 19 27 20 22d 4 27 26 32 29d

Mean 21' 26' 24' Unknown - MW 155: S.E. 8

1 5 15 33 1 8' 2 9 27 51 29' 4 13 47 99 53d

1 62 90 126 93'

Mean 9' 28b 61' 2-EthYl-5-methylpyrazine: S.E. 10

2 77 118 144 113' 4 103 142 167 137d

Mean 81' 1 17b 146' Benzaldehvde: S.E. 4

1 12 25 39 25' 2 19 31 43 3 1" 4 27 35 52 3 8d

Mean 19' 30b 45'

Contents of volatile flavor compounds are based on integrator response to pentadecane. Data for 3 replications and 2 adsorbents (Tenax, CPKS) have been pooled for analysis of variance. Interactions between temperature, time, and adsorbent effects were not significant (p>O.O5). Temperature means with same superscripts (a-c) are not significantly different (p>O.OS) for each compound. Time means with same superscripts (d-f) are not significantly different for each compound.

be considered separately. Significant interactions between temperature and time dictate that each factor must

Page 254: Instrumental

Table 6 Influence of purge temperature, time, and adsorbent on the recovery of key volatile flavor compounds identified through multivariate statistical techniques."

Content (ng/g)

50 70 90 Mean

Trimethylpwazine*: S.E. 25

Tenax 1 65'" 107& 121bX

2 8 Sb" 1 17bx 1 77'

4 76& 171" 178"

CP/CS 1 4SE" 7lCb 132-'

2 6SDb 1 1 6BCx 1 1 3BcDy

4 1 09'- 10SBCDy 1 76h

Page 255: Instrumental

Dimethylvinylpyrrole': S.E. 4 (time). 6 [temp.)

1 20 24 45 3 Og

2 27 34 65 42'

4 34 56 76 55'

Tenax Temp Mean 26'" SObX 7OU

CPICS Temp Mean 27Bx 26By 54*y

Contents of volatile flavor compounds are based on integrator response to pentadecane. Data for 3 replications have been pooled for analysis of variance. Means with the same superscript (a-d or A-E) for the purge temperature and time effects for each adsorbent are not significantly different (p>O.O5). Means with the same superscript (x-y) for the adsorbent effects for each purge temperature and time are not significantly different (p>O.OS). * Significant interactions between temperature, time, and adsorbent dictate that each factor must be considered separately.

Significant interactions between temperature and adsorbent dictate that these factors must be considered separately. Time means with the same superscript (e-g) are not significantly different (p>O.O5).

Page 256: Instrumental

239

environmental contaminants, which are more volatile than the volatile flavor compounds present in food. The superior ability of Tenax to trap volatiles with longer retention times, in comparison to Porapak Q, has been demonstrated for plant volatiles [27].

Table 7 Paired t-test comparisons of recovery of volatile flavor compounds from peanut using Tenax and CP/CS adsorbents"

Maximum recoveryb: Mean: - 14 ng/g Std. Error: 4 ng/g t statistic: -3.28 Prob > Itl: 0.0015

Most frequent maximum recovery (90~ for 4 hr): Mean: -11 ng/g Std. Error: 4 ng/g t statistic" -2.84 Prob > Itl: 0.0055

3 Most frequent maximum recoveries (90~ for 4 hr, 90~ for 2 hr, 70~ for 4 hr):

Mean: - 19 ng/g Std. Error: 3 ng/g t statistic: -5.80 Prob > It[: 0.0001

�9 Contents of volatile flavor compounds are based on integrator response to pentadecane. Positive difference value indicates greater recovery with the CP/CS adsorbent. b Maximum recovery was achieved at a number of temperature-time combinations depending upon the adsorbent, compound, and year.

The identification of phenylacetaldehyde as a component of the key variable set when the volatiles were trapped on Tenax, but not when trapped on CP-CS may indicate differences in the affinity of these adsorbents for different flavor compounds. Significantly more phenylacetaldehyde was recovered with the Tenax adsorbent than with the CP/CS adsorbent. Connick and French [42] also noted a lower recovery of phenylacetaldehyde with trapping on Carbotrap in comparison to trapping on Tenax. The low recovery was attributed to aldol condensation reactions with the basic graphitized carbon black adsorbent.

Page 257: Instrumental

240

Table 8 Influence of adsorbent on the recovery of key volatile flavor compounds identified through multivariate statistical techniques. ~

Content (ng/g) Compound Tenax CP/CS S.E.

Vinylphenol 530' 397' 115 2, 5-Dimethylpyrazine 242' 217' 23 Acetylpyrrole 23' 13 b 4 Phenylacetaldehyde 85' 18 b 11 2, 3-Dihydro-3,5-dihydroxy-6-methyl- 12" 10" 4 4Hpyran-4-one Hexanal 27' 20' 4 Unknown - MW 155 38' 29" 6 2-Ethyl-5-methylpyrazine 122" 107" 8 Benzaldehyde 31" 32" 3

~ Contents of volatile flavor compounds are based on integrator response to pentadecane. Data for 3 replications, 3 purge temperatures (50, 70, 90~ and 3 purge times (1, 2, 4 hr) have been pooled by the analysis of variance to test for a trap (adsorbent) main effect. Interactions between trap (adsorbent) and temperature and/or time effects were not significant (p>0.05). Means within rows with the same superscript (a-b) are not significantly different (p>0.05).

CONCLUSIONS

In this study, a headspace analysis method for the isolation of volatile flavor compounds from peanut butter was developed. The headspace analysis method provides a representative sample of the volatile flavor compounds present in equilibrium with the food. The conditions for the maximum recovery of volatile flavor compounds from peanut butter include trapping on Tenax-GC with a purge temperature of 90~ for 4 hr. The recovery of a majority of volatile flavor compounds was greater when Tenax was used as an adsorbent rather than CP/CS. Frequency table analysis of ranks and analysis of variance of a key variable set of compounds selected through multivariate statistical techniques were used to determine the conditions for the maximum recovery of volatile flavor compounds from peanut butter. The headspace analysis method developed in this research will be applied to future studies to determine the effects of postharvest and processing treatments on the flavor quality of peanuts.

Page 258: Instrumental

241

REFERENCES

Johnson, BR, Waller, GR, Foltz, RL. J Agric Food Chem 1971; 19:1025-1027.

Buckholz, LL, Jr, Daun, H. In: Teranishi R, Barrera-Benitez H, eds. Quality of Selected Fruits and Vegetables in North America. Washington, DC: American Chemical Society, 1981; 163-181.

Pattee, HE, Singleton, JA, Johns, EB. Agric Biol Chem 1971; 19: 134-137.

4 Forss, DA. Prog Chem Fats Other Lipids 1972; 13(4): 177-258.

Litman, I, Numrych, S. In: Supran MK, eds. Lipids as a Source of Flavor. Washington, DC: American Chemical Society, 1978; 1-17.

Teranishi, R. (1989). In Teranishi, R, Buttery, RG, Shahidi, F, eds. Flavor Chemistry: Trends and Developments. Washington, DC: American Chemical Society, 1989; 1-6.

Brown, DF, Senn, VJ, Dollear, FG. J Agric Food Chem 1973; 21:463-467.

Walradt, JP, Pittet, AO, Kinlin, TE, Muralidhara, R, et al. J Agric Food Chem 1971; 19: 972-979.

Mason, ME, Johnson, B. Hamming, M. J Agric Food Chem 1969; 14: 454-460.

10 Shu, CK, Waller, GR. J Food Sci 1971; 36: 579-583.

11 Ho, C-T, Lee, M-H, Chang, SS. JFood Sci 1981; 47:127-133.

12 Buckholz, LL, Jr, Withycombe, DA, Daun, H. J Agric Food Chem 1980; 26: 760-765.

13 Buckholz, LL, Jr, Daun, H, Stier, E, Trout, R. J Food Sci 1980; 45: 547-554.

14 Fore, SP, Dupuy, HP, Wadsworth, JI. Peanut Sci 1976; 3" 86-89.

15 Fore, SP, Fisher, GS, Legendre, MG, Wadsworth, JI. Peanut Sci 1979; 6:58-61.

16 Weurman, C. J Agric Food Chem 1969; 17: 370-384.

17 Dravnieks, A, O~Donnell, A. J Agric Food Chem 197 I; 19:1049-1056.

18 Jennings, WG, Filsoof, M. J Agric Food Chem 1977; 25: 440-445.

Page 259: Instrumental

242

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

Buttery, RG, Seifert, RM, Ling, LC, Soderstrorn, EL, et al. J Agric Food Chem 1982; 30: 1208-1211.

Reineccius, GA, Anandaraman, S. In Lawrence JF, eds. Food Constituents and Food Residues. New York: Marcel Dekker, 1984; 195-293.

Olafsdottir, G, Steinke, JA, Lindsay, RC. J Food Sci. 1985; 50:1431-1436.

Suzuki, J, Bailey, ME. J Agric Food Chem 1985; 33" 343-347.

MacLeod, G, Ames, JM. J Food Sci 1986; 51" 1427-1434.

Vercellotti, JR, Kuan, J-CW, Liu, RH, Legendre, MG, et al. J Agric Food Chem 1987; 35: 1030-1035.

Vercellotti, JR, St. Angelo, AJ, Legendre, MG, Sumrell, G, et al. J Food Comp Anal 1988; 1 239-249.

Risch, SJ, Reineccius, GA. In Parliment, TH, McGorrin, 1LI Ho, C.-T, eds. Thermal Generation of. Aromas, Washington, DC: American Chemical Society, 1989, 42-50.

Cole, RA. J Sci Food Agric 1980; 31" 1242-1249.

Mosesman, NH, Betz, WR, Corman, SD. LC-GC 1988; 6: 328-336.

Sanders, TH, Vercellotti, JR, Blankenship, PD, Crippen, KL, et al. J. Food Sci.1989; 54:1066-1069.

Bondarovich, HA, Friedel, P, Krarnpl, V, Renner, JA, et al. J Agric Food Chem 1967; 15: 1093-1099.

Friedel, P, Krampl, V, Radford, T, Renner, JA, et al. J Agric Food Chem 1971; 19" 530-532.

Kinlin, TE, Muralidhara, R, Pittet, AO, Sanderson, A, et al. J Agric Food Chem 1972; 20" 1021-1028.

Pittet, AO, Muralidhara, R, Walradt, JP, Kinlin, T. J Agric Food Chem 1974; 22: 273-279.

Vitzthurn, OG, Werkhoff, P. J Agric Food Chem 1975; 23" 510-516.

Vernin, G, Petitjean, M. In Vernin G, eds. Chemistry of Heterocyclic Compounds in Flavours and Aromas. Sussex, England: Ellis Horwood Limited, 1982; 305-342.

Page 260: Instrumental

243

36 Ho, C-T, Jin, QZ, Lee, M-H, Chang, SS. J Agric Food Chem 1983; 31 1384-1386.

37 SAS Institute Inc. SAS/STAT User's Guide, Ver. 6, 4th Ed., Cary, NC, 1989.

38 Maarse, H, Visscher, CA. In Volatile Compounds in Food - Qualitative and Quantitative Data, Vol. II. Zeist, The Netherlands: TNO-CIVO Food Analysis Institute, 1989; 76.

39 Mason, ME, Waller, GR. J Agric Food Chem 1964; 12: 274-278.

40 Conover, WJ. Practical Nonparametric Statistics, 2nd. Ed., New York: John Wiley & Sons, 1980.

41 Tabachnick, BG, Fidell, LS. Using Multivariate Statistics. New York: Harper & Row, 1983.

42 Connick, WJ, Jr, French, RC. J Agric Food Chem 1991; 39: 185-188.

ACKNOWLEDGMENTS

We thank J.R. Vercellotti for his input and valuable discussions, E.J. Williams for providing the peanut samples, and E. St. Cyr, Jr. for his assistance in sample preparation.

Page 261: Instrumental

This Page Intentionally Left Blank

Page 262: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 245

GC-MS(EI, PCI, NCI, SIM, ITMS) Data Bank Analysis of Flavors and Fragrances. Kovats indices a

*b , , �9 G. Vernin , C. Lageot b, and C. Parkany~ c

bChimie des ArSmes-Oenologie, Associ~ au CNRS, URA 1411, Facult~ des Sciences et Techniques de St-J~.rSme, Case 561, F13397 Marseille C~dex 20, France

CDepartment of Chemistry, Florida Atlantic University, PO Box 3091, Boca Raton FL 33431-0991, USA

1. INTRODUCTION

Regardless of the method of isolation of volatile fragrant compounds (1, 2) in essential oils and aromas, their analysis and identification would not be conceivable without coupled GC-MS which is the best available method at the present time. Thanks to this technique which was originally developed in 1967 and subsequently improved upon, thousands of flavoring and fragrant compounds have been identified and the information about them compiled in a number of publications (3-12). Upon bombardment with electrons, a molecule will undergo fragmentation to an extent which will depend on its stability. The observed fragments and their relative intensities are characteristic of each molecule.The obtained data are stored on computer disks with a data acquisition system as an integral part of the instrument. It is thus possible to store a large number of spectra which are subsequently compared with a data bank linked to the above system, in order to facilitate their identification. Computerization in flavor research has been introduced (13) and numerous data banks have been developed in the last twenty years. The respective references are given in Table 1. In addition to a chromatogram reconstructed on the basis of the total ionization current which represents a digital imprint of a mixture subjected to analysis, a listing is obtained which can contain hundreds of spectra depending on the complexity of the mixture.

aSome parts of this chapter have been previously published in Analusis, 20(7) 34- 38 (1992) and are being reproduced here with permission of the editor. Author to whom correspondence should be addressed.

Page 263: Instrumental

246

Table 1 Compilation of information on electron impact (El) mass spectra (reviews, data bases and data banks).

Publications Authors (Ref.)

Monoterpenoid hydrocarbons

Monoterpenoid alcohols Monoterpenoid aldehydes and ketones Esters of monoterpenoid alcohols Monoterpenes and derivatives Sesquiterpenes

Terpenes and related compounds

Ryhage and Von Sydow (14) Thomas and Whillhalm (15) Von Sydow (16) Von Sydow (17) Von Sydow (18) Von Sydow (19) Hirose (20) Hayashi et al. (21) Yukawa and Ito (22) Moshonas and Lund (23)

800 volatile compounds (flavors, fragrances) Jennings and Shibamoto (24) Diterpenes, terpenes and terpenoids Enzell et al. (25-31) Isoprenoids from tobacco Enzell et aL (32) Heterocycles Vernin (7) Natural and synthetic flavors and fragrances Tucker and Maciarello (33)

Mass spectra data banks and Library search (Type of compounds, origin) Monoterpenes and derivatives (Sweden) Monoterpenes and derivatives (Japan) US Environmental Protection Agency Collection of mass spectral data (USA) Registry of mass spectral data (USA) Compilation of mass spectral data (France) EPA/NIH mass spectral data base (USA) Computer GC-MS/Kovats indices Library search SPECMA data bank of volatile compounds of flavors and fragrances (France) (at the present time not commercialized) Eight-peak index of mass spectra (England) NBS library compilation (USA)

Von Sydow (19) Yukawa and Ito (22) MSSS (34) Middledisch (35) Stenhagen et aL (36) Cornu and Massot (37) Heller and Milne (38, 39) Craveiro et aL (40, 41)

Petitjean et aL (42-44)

Vernin etaL (45-47) Mass Spectrometry Data Center (48, 49) Finnigan Mat (50)

Page 264: Instrumental

247

Table 1 (Continued)

Publications Authors (Ref.)

PBM data base (USA)(HP59943A) Data base of essential oils CD and DC Rom systems for mass spectral data (Japan) Compilation of mass spectra of volatile compounds in foods (The Netherlands) Wiley/NBS registry of mass spectral data (USA) MPI library of mass spectral data (Germany) NIST/EPA/NIH mass spectra data base (USA) Bench-top/PBM version 3.0 Bench-top GC/MS

Hewlett Packard (51) Chien (52) Wiley and Sons (53)

De Brauw et al., TNO (54, 55) McLafferty (56) McLafferty and Stauffer (57) Henneberg et al. (58) NBS(59, 60)

McLafferty (61) Umano (62)

However, answers obtained from existing data banks are often incorrect or non- existent. It is estimated that, on average, only 25% of answers are correct in the case of essential oils and that this percentage is even lower in the case of food aromas containing numerous heterocyclic compounds.

There are many reasons why these answers are incorrect. a) Dissimilarity index comparing the spectrum of the unknown with that of a reference compound is too high because of the parameters of the instrument (quadrupole or magnetic) or the analytical conditions (saturated spectra, source, temperature, etc.) b) Several compounds give a single peak in the spectrum of a mixture. In those cases where one of the products is identified, a computer program makes it possible to substract the spectrum of this known substance and to obtain the spectrum of the unknown. c) Results for trace substances (the background noise is too prominent).

No answers can be obtained mostly in those cases where the data bank does not contain the reference spectrum or the dissimilarity index exceeds a threshold value.This means that it is necessary to make a visual comparison of the spectrum of the unknown with the libraries of available spectra or with spectra published in various publications. On the other hand, the data bank must contain several mass spectra of the same compound, especially when they do not have the same base peak. Quadrupole apparatus gives more important fragments at m/z 41 and 39 than the magnetic one. This fact must be taken into account. This is a long and exacting operation. However, it can be shortened if the principal fragmentation patterns of the molecules are known.

Page 265: Instrumental

248

In the case of terpene, sesquiterpene and diterpene derivatives, fragmentation processes have been described in several books (37, 63-65), reviews and other publications (25-32). Mass spectra of heterocyclic compounds found in food flavors and Maillard reaction have been compiled (7, 66). However, identification based only on electron impact (El) mass spectra has a relatively limited usefulness. Chromatographic data, selected ion monitoring (SIM) and gentle ionization techniques leading to quasi molecu lar ions are needed, as well as the use of high resolution mass spectrometry in GC/MS coupling (67).

2. CHROMATOGRAPHIC DATA

Retention times (RT) and relative retention times with respect to a standard ((z R ) cannot be used because these quantities are not reproducible and vary greatly with the temperature of the chromatographic column. Kovats indices (KI) introduced by Kovats in 1958 (68) do not suffer from this disadvantage. At isothermic temperature, Kovats uses the following logarithmic equation with linear alkanes as reference compounds

KI=100n + 100(l~ " I~ ~

log t'R(n+l )" log t'R(n)

where t'R(x), t'R(n) and t'R(n+l) are the reduced retention times of the compound X and the linear alkanes with n and n+l carbon atoms, respectively, which are eluted just before and after compound X. Their reproducibility on polar columns (Carbowax 20M, DB WAX, FFAP, BP 20, HP 20) and nonpolar columns (SE 30, SF 96, OV 1, OV 101, OV 117, DB 1, DB 5) is good under similar GC conditions on a given column.

In linear programmed temperature, Van den Dool and Kratz (69) use the following formula:

X M(n) /

KI = 100 n + 100i(/. '~ \ M(n+i) " M(n) /

where X, M(n ) and M(n+i ) are either the retention temperatures or the adjusted retention times of straight-chain aliphatic esters.

The calculation of KI values starts with the injection of either a standard hydrocarbon mixture (C 6 to C22 ) for CW 20 M and (C 6 - C30) for OV 101 (or linear ethyl esters) under the same linear programming conditions. Their retention times are recorded directly or manually by the computing integrator when peak X in the sample appears between hydrocarbon (or aliphatic ethyl ester) peaks with n and n+l carbon atoms of n-paraffin (or straight-chain of the acid moiety of ethyl ester).

Page 266: Instrumental

249

The Kl(x ) is calculated from the following equation:

I tR(x) " tR(n+l ) / Kl(x )= 100n + 100 . . . .

tR(n+l) tR(n)

The software of the integrator can detect each peak and calculate each KI value automatically and print it out with other GC data

The dependence of retention index towards temperature has been extensively studied (70).

In the programmed temperature mode which is the usual case, variables such as carrier gas flow-rate and program rate affect the measurement since they determine the temperature range that the sample is exposed to prior elution.While temperature has a relatively little effect on Kovats indices on nonpolar columns, it can have quite marked effects on polar phases.

According to Shibamoto (71), theoretically, it is necessary to use isothermal conditions (i.e. the Iogaritmic equation) to calculate the Kovats indices.

The use of Kovats indices was recommended by a number of authors (7, 42-45, 72-77).

In GC/MS (El, CI) high search performance is increased by combining retention indices and mass spectra in mass library search of volatiles (7, 40, 45-47, 78). They can be also used as computer-assisted correlation with aroma (79). Owing to this importance, Kovats indices have been compiled in various reviews, books and many other publications (See Table 2). Andersen et aL (82-85)identified sesquiterpene hydrocarbons and heteroannular dienes in various essential oils using retention data.

Test searches for ~decalactone and volatiles of jasmine absolute and men's Cologne were carried out using a search file created for about 2.000 compounds (77). Ramaswami et al. (90) reported a compilation of 60 sesquiterpene hydrocarbons in alphabetical order as well as their Kovats indices on polar and nonpolar columns. They noted that retention indices using fatty acid ethyl esters calibration or linear hydrocarbons, however occurate and reproducible, do not by themselves represent conclusive evidence for the identification, mass spectra being the decisive tool.

Davies (91) tabulated some 900 Kovats indices of almost 400 monoterpene and sesquiterpene derivatives on methyl silicone and/or Carbowax 20 M liquid phases. Kovats indices of heterocyclic compounds have also been reported in numerous papers dealing with food flavors, Maillard reaction, model systems (7) and yeast extracts (93).

In coupled GC/MS one can also use a number of scans but a prerequisite for this is to find at least ten compounds for which the Kovats indices are known and which are uniformly distributed on the reconstructed chromatogram. A simple program called MBASIC.SCAN1 using the linear relationship KI = a (scans) + b, can be used to calculate all Kovats indices for the listing (94).

Page 267: Instrumental

250

Table 2 Kovats indices: theory and compilation

Compounds Authors (Ref.)

Aliphatic halides, alcohols aldehydes and ketones Aliphatic, alicyclic and aromatic compounds Esters (linear temperature) Sesquiterpene hydrocarbons Theory of the retention index system Retention indices Calculation and application of the retention indices Review on the use of retention indices Monoterpene hydrocarbons Volatile compounds of flavors and fragrances (1240 compounds) Monoterpenes Kovats indices as a preselection routine in mass library search of volatiles in essential oil analysis Diterpene hydrocarbons Retention index library Dependence of retention index on temperature Use of retention index mass spectral search for identification of the volatiles in fragrances Retention indices in essential oil analysis (183 compounds) Sesquiterpene hydrocarbons (60 compounds) Monoterpene and sesquiterpene derivatives (a review, 400 compounds) Natural and synthetic pyrazines Yeast extracts

Kovats (68, 80)

Wehrli and Kovats (81) Van Den Dool and Kratz (69) Andersen et aL, (82-85) Erdey et aL, (86) Ettre (72) Majlat et aL (87)

Haken (73) Saeed et al. (74) Jennings and Shibamoto (24)

Swigar and Silverstein (88) Alencar et al. (75)

Perry and Weavers (76) Sadtler research laboratories (89) Albaiges and Guardino (70)

Yamada et al. (77)

Shibamoto (71)

Ramaswami et al. (90)

Davies (91)

Mihara and Masuda (92) Ames and Elmore (93)

Page 268: Instrumental

Table 3. Comparison between experimental and calculated Kovats indices (KIA) of methyl esters on a nonpolar column*.

~~ ~ ~

Series Products Scans(S) KIA(exp)a KIA (calc)b Linear equationsC KIA(calc) =

1 Methyl n -heptanoate Methyl n -0ctanoate Methyl n -nonanoate

2 Methyl n- nonanoate Methyl n -decanoate Methyl n- undecanoate

3 Methyl n -undecanoate Methyl n -dodecanoate Methyl n dridecanoate

Methyl n -tridecanoate Methyl n 4etradecanoate Methyl n -pentadecanoate

Methyl n -pentadecanoate Methyl n -hexadecanoate Methyl n -heptadecanoate

201 1007 31 2 1107 429 1207

429 1207 543 1307 653 1407

653 1407 748 1507 840 1607

840 1607 937 1707 1016 1807

1016 1807 1100 1907 1178 2007

1008 1105 0.877 (S) + 831.6 1208

1206 1308 1406

0.893 (S) + 823.4

1406 1508 1.069 (S) + 708.1 1606

1606 1717 1803

1.1 32 (S) + 652.7

1806 1909 1.234 (S) + 552 2006

Page 269: Instrumental

t4 vl t 4

Table 3 (Continued)

Series Products Scans(S) KIA(exp)a KIA(calc)b Linear equationsC KIA (calc) =

6 Methyl n -heptadecanoate Methyl n -0ctadecanoate Methyl n -nonadecanoate Methyl n -eicosanoate

1178 2007 2003 1255 2107 21 13 1.430 (S) + 319

2207 1389 2307 2305

a Aliphatic methyl esters have been obtained by methylation of the acid fraction of Cisfus ladaniferus essential oil from southeastern France (Esterel) (95).

Reported by Jennings and Shibamoto (1980). Calculated from linear equations: KIA = a . Scans + b according to the M.BASIC. SCAN1 program.

Page 270: Instrumental

253

To obtain the calculated indices with a better accuracy, it is necessary to work with a series within 200 to 300 index units because the above relationship is not linear. If linear alkanes or straight-chain methyl or ethyl esters are present in the medium, the task is simplified and excellent accuracy is obtained as shown in an example in Table 3.

3. SELECTED ION MONITORING (SlM)

An approach complementary to the use of Kovats indices, useful especially in the case of complex mixtures, is the selection of a certain number of characteristic fragments of a particular compound or a homologous series. This technique is called selected ion monitoring (SlM). Table 4 shows some of these ions for different groups of products. Quantitative determinations can be made from calibration curves.

Hirvi and Honkanen (96) claimed that determination of small quantities of a substance by MS is possible using the mass fragmentographic selected ion monitoring (SIM technique) as GC detector. By monitoring ions of one or some few specific masses of the whole spectrum, a thousand-fold increase in sensitivity (picograms amounts) and in specificity can be obtained.

The quadrupole mass filter method is more practical, cheaper and easier to use than the magnetic sector method. They applied this technique to the study of the major volatiles of berries of the genera Vaccinium and Fragaria growing in different areas in southern and western Finland. For example, furaneol can be detected in the berries of strawberry varieties by selecting ions at m/z 142 and 43, 7-1actones at m/z 85, trans-2-hexenal at m/z 42 and 57 and ethyl esters at m/z 88, 43, 60, respectively.

Selected ions for acids and esters upon NCI/OH" were reported by Hendriks and Bruins (97) (See Table 5).

Vernin et aL (98) used the SIM technique upon El to study the heavy fraction of a juniper essential oil (See Table 6).

Frey (99) detected synthetic flavorant additives to some essential oils by selected ion monitoring.

Monoterpenoid and sesquiterpenoid fractions of basil essential oils (PCI/NH3) can be separated selecting the ions at m/z 137 and 205 (100) (See Figure 1 and Table 7).

Also SIM (PCI/i-C4H10) makes it possible to separate the main sulfide components of garlic essential oils by selecting ions at m/z 115, 121,147 and 179 (101,102) (See Figure 2).

Isopentyl alcohol and its esters which are important components of Syrah wines can be selected by using the ions at m/z 55 and 70 upon El (103) (See Figure 3).

Differences between Kovats indices (DIK) on a polar column (Carbowax 20 M) and a nonpolar column (OV 101) can be determined for these selected ions as well. These differences are characteristic of a particular group of compounds. This can be seen from the average values reported in Table 4 (last column).

Page 271: Instrumental

254

Table 4 Identification of different groups of organic compounds on the basis of ions obtained by the electron impact.(EI ) method and the Kovats indices on polar and nonpolar columns*

Compounds Selected ions (mass fragmentometry)

KID = (KIP- KIA)

Hydrocarbons Straight-chain alkanes Straight-chain alkenes Monoterpenes (C 10H16) Limonene Sesquiterpenes (C 15H24)

Ethers and acetals Alkyl ethyl ethers Methylthio alkyl ethers Dimethyl acetals Diethyl acetals Benzyl ethers Diethylene: glycol monoalkyl ethers Ethylene: glycol acetals

Carbonyl compounds Saturated aliphatic aldehydes Alkylmethyl ketones Cis- and trans-aliphatic aldehydes o~,~-Unsaturated compounds 2,4-Alkadienals

Esters Alkyl acetates Alkyl isobutyrates Alkyl butyrates

57,43,71,85 0 56,70 50+/- 10 93,136 160 +/- 50 68 175 93,161,204 195 +/- 60

59,45 50 +/- 20 47 180 +/- 20 75,103,47 200 +/- 10 103,75,47 140 +/- 10 91,107 400 +/- 20 45,59 600 +/- 20 73,45 315

44,57, (M +- 28) 300 +/- 20 43,58 310 +/- 30 41,42,55,69 375 +/- 30

81 425 +/- 30

43,61 265 +/- 30 43, 71 200 +/- 20 43,71 230 +/- 20

Page 272: Instrumental

255

Table 4 (Continued)

Compounds Selected ions (mass fragmentometry)

DIK = (KIP- KIA)

Methyl esters Ethyl esters cis-3-Hexenyl esters trans-2-Hexenyl esters Linalyl esters Cyclohexyl esters Citronellyl esters Geranyl esters 13-Phenethyl esters Benzyl esters Alkyl benzoates Alkyl salicylates Alkyl cinnamates Alkyl anisates Alkyl anthranilates 7-Lactones 8-Lactones

Alcohols Secondary aliphatic alcohols Primary alcohols (aliphatic saturated) 1 -Alken-3-ols

Acids Fatty acids with a straight chain

74,43,87 88,101 82,67 67,82 93,80 67,82 69,82 69,80,93 104 91,108 105,77 120,92 131,103 135 119 85 99

45 31,56 57

60,73

240 +/- 20 240 +/- 20 280 +/- 20 280 +/- 20 270 +/- 30 280 +/- 20 280 +/- 40 340 +/- 40 520 +/- 40 540 +/- 50 485 +/- 40 520 +/- 50 640 +/- 30 680 +/- 30 820 +/- 30 660 +/- 30 680 +/- 30

410 +/- 20 455 +/- 20 455 +/- 20

800 +/- 30

* G. Vernin, unpublished results.

Page 273: Instrumental

256

Table 5. Selected ions in NCI/OH of acids and esters in Cannabis sativa essential oil (97)

Selected ions (RCOO') Compounds

87 (C4H702)"

73 (C3H502)"

115 (CsH 1102) -

101 (C5H902)"

59 (C2H302)"

129 (C7H 1302)"

99 (C5H702)"

Butyric acid, isobutyrates, butyrates

Propionates

Hexanoic acid and hexanoates

Isovalerates and valerates

Acetates

Heptanoic acid and heptanoates

Tiglates a

a In geranium essential oils (136)

Table 6 A SlM (GC-MS/EI) study of the heavy fraction of a Juniper essential oil (98)

Selected ions Principal separated compounds

69

93 119

121

136

154 105,161 189,204 105,161,220

(E)-~-Elemene (1081), nerolidol (1654), cadinenes (1316-1324), (z-cadinols (1825-1877), C 15H24 (1194) farnesol (2001), spathulenol (1752), a ketone (1427) J~-Elemene (1080), (z-humulene (1190) 7-Cadinene (1323), Ar-curcumene (1333), germacrene B (1251), spathulenol (1753), cubenol (1682), C15H22 (1688) (E)-(z-Cadinol (1877), (Z)-e~-cadinol (1825), 7-muurolene (1192), (E)-~-elemene (1084) e~-Terpineol (1209, terpinen-4-ol)-(E)-~-elemene (1074- 1083) etc. Terpinen-4-ol (1081 ) ec-Muurolene (1271), 8- and 7-cadinenes (1316-1326) T. cadinol (1808), r (1877), e~-ferulene (1362) ~-Elemene (1084), germacrene B (1248+1251) calamenols (2004,2022,1938), spathulenol (1753), caryophyllene (1592), humulene oxides (1608-1659)

* The corresponding scan numbers are given in parentheses

Page 274: Instrumental

mlz 137 m/z 205

Monoterpenes + 1,8-cineole Sesquiterpenes

I I c ' l J O I

I

I

t I I

I 1 I I

-

Figure 1 . Comparison of the monoterpenoid (+ 1 ,&cineole)(m/z 137) and sesquiterpenoid (rn/z 205) fractions of Yugoslavian (A) and Malagasy (B) basil oils obtained by mass fragmentornetry in positive chemical ionization (1 00).

Page 275: Instrumental

258

Table 7 Interpretation of compounds selected by ions at m/z 137 and 205 in Figure 1 (100)

Scans KIP Compounds

Selected ions m/z 137

221 1030 (z-Pinene 264 1057 Camphene 314/317 1085 I~-Pi ne ne 332 1100 Sabinene 390 1137 Myrcene 454/460 1182 1,8-Cineole 525 122 7 trans-~-Ocimene

Selected ions mlz 205

1024 1567 cis- (z-Be rgamotene 1078 1590 13- Eleme ne 1096 1607 13-Caryophylle ne 1191 1674 trans- 13-Farnesene 1597 1947 Humulene oxide 1674 2000 C15H24 1800 2085 T. Cadinol

Page 276: Instrumental

Li 2 20

‘1.1 - 60- LO 20-

1000 52 2 3

m / z 179

(Ctl2 = CtI-CHZ-S)2 S

2000 1.35 21

too$ n L 3 3 5

500 2 3 2 L

I500 1 3 1 . 2 2

q 60-

so0 2 3 2 L

I sflo I .31 2 2

Figure 2. Mass fragmentograms upon PCI (isobutane) of the main sulfide components of a Mexican garlic essential oil. Selected ions were m/z 115, 121, 147, 179 between scan 0 and 200 (1 01, 102).

Page 277: Instrumental

Figure 3. GC/MS(EI) reconstructed aromagram of a Syrah wine (A) and selected ions at m/z 55 (€3) and 70 (C) for isopentyl alcohol and isopentyl esters (1 03)

Page 278: Instrumental

Table 8. Interpretation of isopentyl alcohol and isopentyl esters selected by ions at m/z 55 and 70 in a Syrah wine (See Figure 3) (103).

Scans KIP m/z Compounds

364 402 579 620 87 1 1093 1185 1478 1614

1100 1180 1250 1280 1445 1547 1640 1840 1927

45,55,70 55,41,42,43,70 traces 70,43,57,55,85 70,43,56 45,433570 70,43,57,55,127 70,43,71,55 87,70,43,55

lsoamyl acetate lsopentanol lsoamyl butyrate lsoamyl isovalerate lsoamyl hexanoate lsoamyl lactate lsoamyl octanoate lsoamyl decanoate lsoamyl 3-hydroxybutyrate

Page 279: Instrumental

262

The differences are a function of the nature of alkyl groups (straight or branched), for the first members of a homologous series. In the series of linalyl esters, citronellyl esters, geranyl esters, benzyl esters, and phenethyl esters, the average value is that for the butyrates. DIK is a constant for straight chains. The highest values are observed for the formates, lower values for the acetates, and the lowest values for branched chains. Propionates, valerates, isovalerates, and pivalates are characterized by an important fragment at m/z 57, tiglates by a fragment at m/z 83, and hexanoates by a fragment at m/z 99. This means that characteristic fragments and DIK values allow one to obtain information about a particular group of compounds.

4. ION TRAP MASS SPECTROMETRY (ITMS)

Ion trap mass spectrometry (ITMS) can be classif ied as belonging to quadrupole filters (104, 105). It is a three dimensional quadrupole mass spectrometer with MS/MS instrumentation.

Among these advanced techniques, only one has become commercially available. It is a technique called mass selective instability (MSI)(106). Figure 4 shows schematically the principle of the method (107).

Filament Terminal electrode

Tension -$ l ~ ~ ( rad io f requency) ] \ 5= = ~ E~= ~

.,-. ~_t~. ~. t ._ ~ v

Terminal electrode

Electron multiplier

Figure 4. Simplified scheme of ion trap mass spectrometry (107).

The electrodes (circular and terminal) are hyperbolic. Tension in the radio- frequency region (fixed frequency, variable amplitude) is applied to the central electrode (the terminal electrodes are grounded). All the ions above a certain m/z are on trajectories which are in the interior space of the electrodes (hence the name "ion trap"). As the amplitude increases, the ion with a certain m/z become unstable and are ejected in the direction of the terminal electrodes (107).

Page 280: Instrumental

263

The sensitivity of the method is increased by addition of helium (p = 102 pascal). The collisions between the gas and the ions augment the efficiency of ion trapping.

Applications

Adams (108) collected 500 ITMS spectra of volatile compounds in essential oils. Subsequently, in 1991, he published (109) mass spectra of e~- and J3-cedrene, thujopsene, cuparene, and widdrol which are the constituents of cedar wood essential oil. Later, he and Weyerstal (110) compared the ITMS spectra of cis- and trans-sabinene hydrates with those obtained by the electron impact (El) method. ITMS spectra generally resemble the quadrupole mass spectra.

5. CHEMICAL IONIZATION TECHNIQUES

Because in many cases it is not possible to obtain molecular mass by the electron impact (El) technique, since 1966 various authors started using gentler ionization methods. The theory and application of these techniques were developed in Harrison's book (111) and in articles published by several authors (112- 118).

In the electron impact (El) method, the pressure of the source is so low that molecules can exit without any collisions with neutral molecules. In a chemical ionization chamber, the pressure is much higher (0.07 to 1.5 torr.). This means that no ion can leave without a prior collision with neutral molecule(s). These collisions between ions and molecules can lead to a series of chain reactions (e.g., in the case of methane).

During this process, a certain amount of energy is transferred to the derived ion. The result is fragmentation which is milder than with the electron impact (El) method. In many cases, it is possible to obtain quasimolecular ions (M + H) + and (M- H) +.

Chemical ionization leads to the formation of derived ions by reaction between reactive ions and neutral molecules. This phenomenon can be obtained by positive chemical ionization (PCI) (115) as well as by negative chemical ionization (NCI) (116).

Positive chemical ionization (PCI)

The gaseous reagents used are mainly methane, isobutane, and ammonia. The following ions are observed, respectively �9

- with methane: CH5 + (m/z 15), C2H5 + (m/z 29) and C3H5 + (m/z 41)

- with isobutane" C3H 7 (m/z 43), i-C4H 9 + (m/z 57)

- with ammonia: NH4 + (m/z 18), NH4 + . NH 3 (m/z 35) and NH 4+. 2 NH 3 (m/z 52).

Page 281: Instrumental

264

In the presence of a molecule M, the principal reaction is proton transfer:

f~ t foH4 t i-C4H9+ + M ~ i-C4H8

NH4+ NH 3

+ MH +

The reactivity depends on the acidity of the positive ions and the basicity of neutral molecules. Heats of formation of protonated molecules have been reported by Lias et al. (118). In addition to these transfer reactions, secondary reactions are observed: a) Transfer of a hydride ion from the molecule to the reactive cation (with methane as the reagent and saturated aliphatic hydrocarbons and cycloalkanes as the substrates). b) Alkylation with methane and isobutane, especially with molecules containing oxygen and nitrogen c) Association involving hydrogen bonds in the case of ammonia.

NH4 + + M ~ MNH4 + ~ MH+NH3 ~ MH++NH 3

These reactions take place with alcohols, ethers, and esters, but especially with hydrocarbons. Unusual positive ion reagents in CIMS has been described by Vairamani et aL (119).

Negative chemical Ionization (NCI)

The hydroxide ion, OH" is most commonly used among the various ions utilized for this purpose (H', NH2", OH', CH30", CH3S', CN', F', CI'). It is obtained by electron impact from the mixtures N20/He/H 2 (1 : 1 : 1) or N20/He/CH 4 (1 : 1 : 1) (120).

a) Proton transfer reactions. These reactions take place with acids, alcohols, ketones, and alkenes but not with saturated hydrocarbons.

OH- + RCOOH ~ RCOO" + H20

OH" + ROH ~ RO" + H20

OH" + RCH2-CI-R' . ~ R-C=',CI-R' +H20 O H I O"

Page 282: Instrumental

265

b) Substitution and elimination reactions.

(A" + BC ~ AB + C')

"- RCOO" + XR' I - X" RCOOR' +

- ! ~ R-COX + R'O"

i = RO" XR' +

X" + R-O-R' - [ XR + R'O"

H I

OH" + R-CH-CH2OR ~ H20 + R-CH =CH 2 + R'O"

c) Reactions involving association via hydrogen bonds (CI" ion). The associated molecules are in equilibrium with associated ions (cf. Eq. 1)"

1 2 XHCI" ,, - X . HCI ~ X" + HCI

However, if the acidity of XH is too low, hydrogen bonds cannot be formed. If XH is strongly acidic, the associated ion decomposes according to Eq. 2.

The orders of acidities of different molecules and the basicities of the negative ions have been established (117).

A p p l i c a t i o n s

The positive and negative ionization techniques are mostly used in analysis of essential oils and aromas. The available information is summarized in Table 9.

Negative chemical ionization (NCI) of unsaturated terpenoid hydrocarbons gives molecular ions with low intensity because protons are difficult to abstract. Furthermore, the ion (M - 1) can react with the gaseous reagent nitrous oxide. Saturated terpenes cannot be ionized by this technique.

The behavior of monoterpenes and some sesquiterpenes of Bulgarian rose oil in positive chemical ionization (PCI) was studied by Hadjieva et al. (128). In the case of monoterpenes, o~-humulene, I~-caryophyllene, and J3-bergamotene give an important fragment at m/z 81. In this case, chemical ionization is not very useful because El spectra still give the molecular ion. However, certain fragments are characteristic of a given structure.

Page 283: Instrumental

h, o\ o\

Table 9. Some applications of the positive (PCI) and negative (NCI) chemical ionization methods in flavors and fragrances

Compounds Methods Authors (Ref.)

2-Norbornyl derivatives Alcohols, esters and oxygenated

Terpenoids 1,3-Bis (2-chloroethyl)-l -nitrosourea (an anticancer agent) Alkenes Aldehydes, ketones and alcohols (terpenoids)

Alcohols Valeriana officinalis essential oils (elemol, valeranone, valeranal and a-kessyl alcohol) Bulgarian rose oil (Rosa darnascena Mi//. ) (cis- and trans - linalool oxides ) Essential oils Aliphatic alcohols and esters Cyclohexanone

CI PC l/i-C4 H

NCVOH- PCl/i-C4H

0

0

PCIA-C~H~O

NCVOH- NCVOH-

PCI/CH4, NH3

PCI/CH4

NCVOH- PCl/i-C4H10, NH3 PC VNH3

Jelus eta/. (121) Bruins (122)

Bruins (1 22) Weinkam and Lin (123)

Budzikiewicz and Busker (124) Knight eta/. (1 25)

Houriet et a/. (1 26) Hendriks and Bruins (1 27)

Hadjieva eta/. (1 28)

Bos et a/. (1 29) Williams and May (130)

Tabet and Fraisse (1 31 )

Page 284: Instrumental

Table 9 (Continued)

Compounds Methods Authors (Ref.)

Holly essential oil (Ruscus aculeatus)

Cyclic ethers

Roman charnomilla Mixtures (flavorings) Cyclic monoalcohols (stereoisomeric)

Hemp (Cannabis sativa L. )

Mentha spicata

Geranium essential oils

Stereoisomeric norbornenyl compounds Basil essential oils

Saturated and unsaturated cyclic and

aliphatic alcohols Alkyl esters

Conjugated dienes

PC I/NH 3

NCI/OH-, NH2-

NCVOH- CI PCl/i-C4H10, NH3

NCI/OH-

NCI/OH-

PCl/i-C4H1 0

NCVOH- PC I PCl/i-C4H1 0 PCI/CH4, NH3

PCM-C4Hl o, CH4

PCl/i-C4Hlo

Fellous and George (1 33a)

De Puy (1 33b)

George (1 133b) Rapp et a/. (1 14) Winkleretal. (134)

Hendriks and Bruins (97)

Papageorgiou etal. (1 55)

Fraisse etal. (1 35)

Vernin eta/. (136) Jalonen etal. (137) Vernin etal. (1 00)

Sarris et a/. (1 38)

May and Williams (1 39)

Einborn e l a/. (1 40a)

Dootlittle eta/. (1 40b)

Page 285: Instrumental

Table 9 (Continued)

Compounds Methods Authors (Ref.)

Stereoisomeric norbornenols Miscellaneous terpenoids An ortho ester from the Mentha piperita essential oil Garlic essential oils

Eniantomeric menthols

Unsaturated alcohols Terpenoid and nonterpenoid esters and alcohols Bicyclic sesquiterpene alcohols Humulene diepoxides lsoborneol and isobornyl acetate, and

essential oils

PCI E I/C I PCI/i-C4H10

PCl/i-C4H10

NCVOH- CI

PCVNCI PCVNCI PCl/i-C4H1 0

NCVOH-

Jalonen and Taskinen (141) White (2) Koepsel etal. (1 42)

Vernin etal. (101, 102)

Tabet (1 43)

Munson etal. (1 44) Lange and Schultze (145)

Madhusudanan et a/. (1 46) Lam and Deinzer (147) Bruins (117)

Bruins (1 17)

Page 286: Instrumental

Table 9 (End)

Compounds Methods Authors (Ref.)

lsopulegol isomers Terpenoid and nonterpenoid esters Volatile esters and phenylpropanoids Thermal degradation of Amadori intermediates

a- and P-Pinene derivatives Juniper essential oils Sesquiterpene hydrocarbons Sesquiterpene alcohols Non alcoholic beverages "Cokta" Sulfur components of chive (Allium Schoenoprasum)

PCl/i-C4H 1 0, NH3 CI PCM-C~H~O, NH3 PCIA-C~H~O

PC I PCIA-C4Hl PCl/i-C4H10 PCl/i-C4HI 0, NH3 PC I/CH 4 NCI (N20/CH4)

Lange and Schultze (1 48) Lange and Schultze (1 48b) Lange and Schultze (1 54) Vernin eta/. (149)

Badjah etal. (1 50) Vernin eta/. (98) Schultze etal. (151) Schultze eta/. (1 52) Zupanc etal. (1 992) Carceles (1 61 )

Page 287: Instrumental

270

Reactive gases i.e. (CH3)3CH, NO, CH3NH 2 add to double bonds of olefins giving rise to chraracteristic fragmentation patterns (124).

A number of papers have been devoted to the NCI behavior (OH-, NH2" ) of cyclic ethers by De Puy et aL (132). In this case the gas phase with amide and hydroxide ions undergoes a ~-elimination which prevails with retro-aldolization reactions.

PCI mass spectra of terpenoid alcohols (borneol, e~-terpineol, linalool, citronellol) were reported by Knight et aL (125). The PCI/NH 3 give best results than the PCI(CH4) mode. Tables with numerical values of mass spectral data obtained

using the NCI technique (OH-) were published (117). The values include the data for 13 esters (formates, acetates, isovalerates), 13 terpenoid alcohols, 8 sesquiterpenoid alcohols, 2 phenols (anethole, eugenol), 4 oxides and 2 terpenoid ketones (carvone, pulegone). This technique is of special interest for (M - H)-ions from alcohols and esters because the PCI technique (isobutane) does not always give the (M + H) + ions. NCI/OH" is particularly suitable for the identification of esters of essential oils (127). Esters are cleaved by an apparent nucleophilic displacement reaction with the formation of RCOO" ions. In the case of alcohols, the RO ion is usually the base peak. More or less prominent loss of a molecule of water from the (M - H)" ion in stereoisomeric carveols suggests their configuration (117).

PCI of alkyl esters were studied by May and Williams (139): 1) CI(MS)in general produces (MH) + ions indicative of the molecular weight,

(RCH2COOH2) + and (RCH2CO) + ions are indicative of the acid moiety, and

(R) + ions indicative of the alcohol moiety.

2) When methane is used as reagent gas: a) in general, mass spectra are more complex than when isobutane is used as reagent gas. b) for methyl and ethyl esters the (MH) + ion diminishes the MS. c) in esters other than methyl and ethyl, the (RCH2COOH2) + ion dominates the

spectra and the (MH) + or (RCH2CO) + is the second major ion.

d) as the acid and alcohol moieties increase in chain length, the (MH) + ion decreases and fragments from the alkyl chain (RCH2) +, (R) +, and (R - H) + assume greater importance. e) (RCH2CO2C2H5)+and (RCH2CO2C3H5) + are found with propyl and higher esters. f) low levels of (M-C2H5)+ and (M-C3H5)+ were found with all esters.

Page 288: Instrumental

271

g) the presence of iso- radicals in either the acid or alkyl moiety increases the contribution from the iso- radical. It also decreases the relative contribution from the (RCH2COOH2) + ion.

3) When isobutane is used as reagent gas: a) the (MH) + ion is the major ion and in general (RCH2COOH2) + is the next major ion. b) as the acid and alcohol moieties increase in chain length, the relative intensities of the (RCH2)+, (R) + and (R-H) + ion increase. c) the presence of iso- radicals increases the relative contribution from the iso- radical. in terpenoid esters, nucleophilic displacement with OH" ions gives carboxylate

ions making it possible to obtain information about the acid in the ester. The PCI mass spectra of twenty alcohols (saturated and unsaturated, cyclic and

aliphatic) at difforent operating pressures and source temperatures using methane or ammonia as reagent gas wore studied by Sarris et al (138). The best conditions for determining the molecular woight of these alcohols wore low temperatures (i.e. 90~ associated with a high pressure of the gas (0.3 mbar). These conditions favored the formation of the major ion (M -17) + and (M - 1)+ when methane was used as reagent gas, and (M - 17) +, M + and (M + 18) + when ammonia was the reagent gas. For determining M.W., ammonia is the preforred reagent gas. Similarly, Lange and Schultze (148b) insist on the importance of the proper choice of experimental conditions with respect to the type of reagent gas, the reagent gas pressure and the ion source temperature. They reported mass spectra of neryl and geranyl acetates at two difforent (PCI/NH3) pressures (0.15 and 0.70 mbar), respectively. At the higher pressure, the base peak occurs at m/z 214 corresponding to the fragment (M + NH4) +.

In general, the PCI technique has been more widely adopted for analysis of carbonyl campounds than the NCI method, and it has been used for sulfur compounds in garlic oil (101,102).

In the NC! technique, correct analysis of unsaturated monoterpenes is complicated because of the secondary reactions between (M - H)" ions and nitrous oxide.

It is also wortwhile to mention Lange's and Schultze's works (145, 148, 154) using PCI (with isobutane and ammonia) on terpenoid alcohols, isopulegols, and sesquiterpene hydrocarbons and alcohols (151,152).

Upon PCI/ i -C4H10 sesqui terpene hydrocarbons give an intense

quasimolecular ion (M + 1 ) + (151 ). The extent of fragmentation is different for the various compounds, permitting a

certain structural classification within this group. Sesquiterpene alcohols and

Page 289: Instrumental

272

esters may yield similar spectra with isobutane impeding unequivocal classification of this class of compounds. With ammonia a typical set of ions (M + 1)+, (M + 18) + and (M + 35) +, respectively, is produced. According to their specific mass numbers, these ions unambiguously characterize the loss of hydrocarbons. The molecular mass is obtained from the species (M + 1)+ and/or (M + 18) +.

Twenty-one sesquiterpene alcohols were investigated by Schultze et aL (152) using isobutane and ammonia as the reagent gases.

The PCI/i-C4H10 mass spectra show intense fragment ions (M + H - H20) + at m/z 205 for all substances. These compounds possess tendency to form different further fragments. This behaviour reveals structural characteristics to a certain degree.

Only three compounds display quasi molecular ions (M + H) + with relative intensity > 10%. Therefore, isobutane is not well suited to confirm the molecular mass and classification of this group of compounds is not unambiguous. With ammonia a typical set of ions is formed: (M + H - H20) +, (M + NH 4 - H20) +, (M +

NH4) + and (M + NH 3 . NH4) +, respectively. These ions make it possible to confirm the molecular mass and to classify this group of compounds.

A number of papers have been devoted to the volatile components of essential oils" Bulgarian rose, Roman chamomilla, hemp (Cannabis safiva L.) Valeriana officinafis L., geranium, basil, juniper, garlic, and chive, as well as to the various flavorings (mixtures) and the products of the Maillard reaction (See Table 7).

As an example, let us examine the behavior of cis- and trans-linalyl oxides present in many essential oils and natural flavors.

Positive chemical ionization (PCI) of these compounds with methane (128) shows a difference between the intensities of the (M + H - H20) + ion which is 55% for the cis-isomer and 30% for the trans- isomer. This can be explained as due to different chemical stabilization of the above cation. The cation derived from the cis- isomer is more stabilized mostly because of the ion-dipole interaction between the positive charge and the vinyl group. In the case of the trans-isomer, the vinyl group is more distant from the positive charge.

cis trans

Figure 5. Configuration of the (M + H - H20) + ions based on the cis- and trans- linalyl oxides (128).

Page 290: Instrumental

273

The same phenomenon is observed with the positive chemical ionization (PCI) using isobutane (135). In the case of cis-isomer the respective ion (M + H - H20) + represents 71% as compared to 34% for the trans- isomer (cf. Figures 6 to 9).

With negative chemical ionization (NCI/OH'), the ion (M - H - H20)" at m/z 151 is the base peak of the cis -isomer, it is 86% in the case of the trans-isomer. In both cases, also the M - H)" ion at m/z 169 is present. It can be assumed that the (M - H - H20 )" ion is formed in three steps :

a) Attack of the OH-ion on the proton with respect to the heterocyclic oxygen, leading to the formation of a carbanion (cf. Scheme 1).

H .)

OH T,

- H20 �9 , - - . - -

H

I (-OH')

H ._ I OH~--'~ H

( M - H - H 2 0 ) m/z 151 (86-100%

Scheme 1. Formation of the (M- H - H20 )- ion by negative chemical ionization

(NCI, OH') of cis- and trans-linalyl oxides.

b) Elimination of the O H ion from the tertiary alcoholic group. c) A new attack of the OH" ion on the two protons of the methylene group in the ailylic position and the formation of the anion (M - H - H20)" stabilized by conjugation.

Page 291: Instrumental

274

Hem " CIS-LI~LOOL ~IDE (E. I . ) Fo~ute 5ru ' te ' C18 !!18 02 (P.M. = 178 ) Origine ' ( ; E ] ~ ] ~ ECYPT;L/EI~I]N et al. ,P~RF. COS'I.A]~I1ES,52,51-~l, 1983. ]Ka : 1878 IXp - 1428 I)I~ : 3.~ Refe~nce : 8: 8

:00

~0"

i4r !1 1 ~" i i I J i i i j i i: i i i i ' i i 1 I " I t i i t t 0 20 ~0 (;0 $0 100 1~0 '.~,0 J.~O 180 200 ~20 2~0 2~0

Spectre en impact elec~:ronique ' 59(188) 43 (48), 68 (34), 94 (34), 41 (28), 111 (28), 55 (25), 67 (25), 93 (25) 81 (28), 83 (14), 53 (8), 79 (8), 77 (2), 137 (2), 155 (2)

MoR ' (Z)-LII~LOOL OXIDE (F) Fot~ule b~'Le ' C18 H18 02 (P.M. = 178 ) Or i 9 i ne ' 3~I~OSA(RE~1011); UL~NI Met a 1., J. EssElfr. oIL RESEARCH, 1991, 83--97. I I (a- 1888 IKp- 1448 DIK- 368 Reference- 8: 8

'~176

i!'l ! ~ i i i I i i i i ' l

20 ~O 60 30 100 I~.~)

, ~ . ,, i I i i i I t I i I i I I

Spec~,re en ~pac~ electronJque ' 5g( l l~) 43 (57), 94 (45), 41 (38), 55 (27),

155 (3), 137 (2) 68 (22), 93 (22), 67 (15), 111 (14)

F i g u r e 6. E l m a s s s p e c t r a o f cis-linalool o x i d e s .

Page 292: Instrumental

275

Horn' CIS-LIN~LOOL ~l])g (P.C.I./i~4H18) Fomule brute'C!8 HI8 02 (P.M. = 178 ) Origine ' GE]~MI~ E~/~;UERMIN et aI.,P~E.CO~.~R~ES,SX, SI-GI, 1983. lHa : !878 IKp : 1428 ])IX : ~58 .qe,~e~ce : 8" 8

.J

+)" ii7%$ ;0. !liL" l

~ ' I i 1 i i " t i '( I i " t I ~ i i i i i i i - ' i '

0 20 10 gO %0 '-~0 :20 I'+O ~.gO I~O -~90 -~20 ...~0 2gO

Gg(188) G7 (85), 153 (G8), 79 (42), 81 (42), 85 (37), 83 (28), 95 (17), 91 (14) 93 (11), 94 (11), G5 (8), 189 (8), 111 (8), 135 (8), 154 (8), 13l (2.)

Motto ' CIS-LIRALOOL OXIDE (N.C.I./OH-) Fomula b~%e' C18 H18 02 (P.H. = 178 ) Origiae ' GXR~MILII E~PI';UERNIN e% al.,PRRF.CO~.AR~ES,52,51-fiI,1983. IKa : 1878 IKp- 1428 DIK- 358 Re~erence- 8: 8

"-)0 ,

~oJ. l

"i 4

~iiilii 0 20 10

I !I ~I �9

i ~i i i i I i ;'i 'i i I i k i ~ i i $0 80 ~.~)0 '-20 '.~0 '.$0 '.%0 "00 220 X~,O 2~0

151(188) 57 (65), 87 (28), 66 (22), 81 (28), 71 (14), 69 (11), 133 (8), 169 (8) 85 (5), I~ (5), 111 (5), 135 (5), 149 iS)

Figure 7. PCI/-i-C4H 10 and NCI/OH" mass spectra of cis-linalool oxides.

Page 293: Instrumental

276

I ~ ' ~-L IRALOOL ~IDE (E.I.) Fomule bru~e ' C18 H18 02 (P.M. : 178 ) Ori�ine ' ~F.]~/~]~ E~PT;UE~IN et aI.,PRRF.CO~I.~OffE~,S2,51-61,1983. !.~a = 1888 ] Xp : 1~.58 DI ]( = 378 Refe~nce : 8: 8

:oo

?

. , )

I i ; I ~ t" i , m

,I!1 20 ~O (0 eO ~O0 250

i i : r ! i t i i 1 I i I i i J i 1~0 1~0 I~0 1SO 200 2~.0 2~0

Spectre en impact electroni�ue ' 59(188) 43 (45), 55 (37), 81 ( 28 ) ,

68 (37), 41 (31), 93 (28), 94 (28), 111 (28), 67 (Z2) 83 (14), 53 (8), 79 (8), ?7 (5), 119 (2), 137 (2), 155 (2)

Nm ' ( E ) - LIi~LOOL O~IDE (F) Fomule brute ' C18 H18 02 (P.M. = 178 ) Ori�ine ' JI~I1ROSA (REUNION);UE]~IIII et al.,J.ESSEiIT.OIL RES~ROI,1991, 83-97. l](a : 1878 IKp : 1418 DIK : 348 Reference - 8: 8

20~ ~7 L~

~ " I I i I t i I' I ' ] i' t i Jl t ~ ! i I 0 20 ~0 ~0 ~0 I~O '-20 '~.0 IgO ~80

8pecire en impact electronique ' 59(188) 43 (83), 94 (48), 39 (15), 81 (15),

I i 1 I I F I 200 -"-"0 2~0 2r

SS (3G), 41 (34), 93 (3B), 68 (24), 6? (2B), 111 (28) 69 (11), 137 (3), 155 (3 )

F i g u r e 8. El m a s s s p e c t r a of trans-linalool o x i d e s .

Page 294: Instrumental

2 7 7

Horn' TPa~IS-LI~LOOL ~IDE (P.C.I./i-C~H18) Fomule brute" C18 H18 02 (P.M. = 178 ) Origine ' (;ERf~I~ E~;UE~HIH et al.,Pt~.CO~.n,qOl~ES,fi2,51-61,1,~ l~a = 1~88 I~p = 14E8 DI~ = 378 ]:~e~nce = 8: 8

t

oi i ' i i j

:!

,

"it ".|g!, ~$g i i ::ti

i J ~ i i I J ~ 1 1 } } 0 .~ qO *0 90 iO0 t20 :~0 1~0 :~0

69( I88 ) 67 (88), 79 (@), 81 (@), 85 (31), 153 (34), [ 91 (11), 95 (11), 93 (5), 94 (S), 189 (2), 111 (

t i 1 I i I 200 220 2,0

83 (25), 65 (11), 71 (11) (2), 135 (2), 137 (2)

Horn ' TRA~-LIHALOOL OXIDE (M.C.I./OH-) Fomule brute ' C18 H18 02 (P.M. = 178 ) Origine ' GERAHII~I E~PT;UERHIH et aI.,PARF.CO~.~IifflES,52,51%l, 1983. l}(a : 1888 l~p = 1458 ])l]( - 378 Reference - 8: B

tO0 B7

'~0"

.o

I i t '.~3

, 6~ I ,'"1 ! I ~!t ,[ " -3 ~ i i i i ( i i i I ~ i i

57(188)

t ~

151 (85), 66 (54), 71 (25), 133 (22), 69 (17), 169 (14), 85 (11), 111 (11) 99 (11), I]1 (8), 1117 (S), 189 (5), 149 (S), 135 (S)

F i g u r e 9. P C I / i - C 4 H I o a n d N C I / O H " m a s s spectra of trans-linalool o x i d e .

Page 295: Instrumental

278

One would not expect too much of a difference between the ions formed from the two isomers, except for the easier approach of the OH" ion in the case of the cis- isomer in the first step of the process. It is surprising that in the NCI (OH') spectra of these two isowers published by Bruins (117), the (M - H) ions are the base peak, even though the (M - H - H20 )" ion represents only 3 - 5%.

As additional examples, the El and PCI/NH 3 mass spectra for 2-acetylfuran (Figure 10), 5-methylfurfural (Figure 11 ), 2-acetylpyrrole (Figure 12) identified in the thermal degradation of the Fruc-Valine Amadori intermediates (103) and several alkylpyrazines (Figures 13 to 21) are given. These mass spectra have been reconstructed from our SPECMA data bank written in Turbo Pascal (version 6) using Pentium 90 (Intel processor)).

The NCI (N20/CH4) technique was recently applied in a study of sulfur components of a chive extract (161) obtained from an aqueous crushed extract treated by ultrasound at room temperature. The NCI spectra of sulfur components do not give the quasi-molecular ion (M-H'). As for diallyl disulfide in garlic, the 1- prop-enyl disulfides in chives give a very abundant ion at m/z 72.

In the PCI method, 2-acetylfuran and 5-methylfurfural give the (M + H) + ion and an adduct cation at m/z 128, (M + NH4)+ which is the base peak for 2-acetylfuran. This ion is very weak in the case of 2-acetylpyrrole (m/z 127).

All alkylpyrazines (PCI/NH3) give the quasimolecular ion (M + H) + as the base

peak. We have also observed a weak peak at m/z (NH4 + + 2 NH3) and an important fragment at m/z (NH3) which is not reported in the reconstructed mass spectra.

The El, PCI/i-C4H10 and NCI/OH" mass spectra of sulfur derivatives found in garlic essential oils have been published elsewhere (101, 102). Allylmethyl disulfide and diallyl disulfide, the most abundant constituents of these oils are of interest. Their mass spectra are shown in Figures 22 to 24.

In the case of NCI, the quasi molecular ions (M - 1) are not observed. The most intense peak at m/z 105 in diallyl disulfide corresponds to the loss of allyl alcohol from the anionic molecule or of allyl carbene from the quasi molecu lar ion (See Scheme 2).

The base peak at m/z 72 in the two mass spectra arises from the homolytic cleavage of the S - S bond in the quasimolecular ions leading to an allylthio radical and a radical anion which cyclizes to give the more stable mesomeric form. in the PCI method, the quasimolecular ions are the base peaks.

Page 296: Instrumental

279

M, om : 2-~CL"rYLFUP~N (E. I , ) Formule br~ate : C6 H6 02 (P.M. = 118 )

I~a : 8S~5 !~p : !SIS DI}( : 6.?.1] ~ n c e : B' B

i �9 ,? 2 ,

o ' i ! ! ~ " i i I i i i I ~ i ' - ~ ' i I i 0 i I i i '

0 20 qO (0 $0 ~00 :~0 :~0 :~0 :~0 ZOO 229 2~0 2;0

Spectre en i~pact; electronique ' 9S(!BB) 111] (39), 39 (21]), 43 (17), 96 (5), 67 (4), 11 (3)

Morn : 2-RCETYLFURAR (P, C, I./RIO) Formule 5ru'~e : C8 H6 02 (P,M. = 111] ) Origine : FRUC.-~JALIME(~ADORI):UERMIM et aI.,B,S,C.F.,4,681-694,1987. IKa = 895 IKp : 1515 DIK = 6ZB ~s = B: B

"I ~o

l

~i' i'l i : ! , I ; I , i I 1 I i 1 , I , , ; ', ~ i

0 20 ~0 60 80 "00 :.'0 ::0

128(188) 111 (%), 111] (IB), 95 (B)

Figure 10. El and P C I / N H 3 m a s s spec t ra of 2 -ace ty l f u ran .

Page 297: Instrumental

280

Morn' ~-tI, ETHYL~RFUR~L (E. I. ) F:r~ule 5rute ' C6 H6 02 (P.ff. : I'6 ) O~i~ine ' FRL~.~LiMF. (~,~Rl);'J~!ll et aI.,B.S.C.F., 4,681-694,1987. IRa : 9~.B IR?- ~,~B DiX : 6-~8 Ref~,,'enc~ : 9: 8

'~: ,~

~ i i I i' i " i i i i i i r i i ~ ! i ' i ~ :

Spectre en ~pact electronique ' 118(188) 189 ( 8 7 ) , 53 (q8 ) , 57 ( 1 5 ) , 39 ( 1 3 ) , 51 ( 1 1 ) , 41 ( 1 9 ) , 81 ( 8 ) , 188 ( 2 )

Nora ' 5-tI~HYLFIER,,FURAL (P, C. I./~3) For~le brute ' C6 H6 02 (P.M. : 118 ) Origine ' FH~.-UALINE(AIIAI)OHI);UERHIM et aI.,H.S.C.F.,4,681-694,1987. l]{a : 9q8 IKp : 1588 Oil( : 641] ~ference : 8: 8

oo!

20"

o i i i i i i i i i I

I

I I

0 20 ~0 60 $0 '~OO ~.O ;~.0 :r "80 200 220 2~0 2fO

111(1B9) 12H (?B), 52 (18)

Figure 11. El and PCI/NH 3 mass spectra of 5-methylfurfural.

Page 298: Instrumental

281

M:~ : 2-AC~tL ,i~,,RC.LF. (E. I . ) Fomule bru'Le ' C6 H? H I 0 1 (P.M. = 189 ) Or !gtne ' F~Uf. "^ ' ~E . . . . �9 .--v,vi (:~RDOI~I);~JERMiM et. aI B.S.C.}'. 4,b81-694,1987 I](a : !858 iKp : 1938 l)ll( = 888 Rcqerence = B: 8

'.0.}

~~ iI. i

Spectre en hpac'l; elec'l:ronique ' 1B9 (82), 6G (57), 39 (3?),

t i ~ ! ~ .' I ! i i i i 11

94(188) 43 (15), 118 (6), 53 (6), 67 (6)

Nor, ' 2-ACk"~LI~, RROLE(P. C. I./MH3) Fomule brute ' C6 H? ~! 1 0 1 (P.M. = 189 ) Ori9ine ' FRUC.~ALIME(~'IAI)ORI);UI~RHIM et aI.,B.S.C.F., 4, b81-G94,1987. l](a = 1858 l](p : 1938 ])l]( : 888 ~s = 8: B

i o o ;

'~ : o

I I I i t ~ I i { t i i ! : t ' i f ~ t ~ } t t

118(188) 94 (2B), 127 (8 ) , 52 (7) , 189 (S)

F i g u r e 12. E l a n d P C I / N H 3 m a s s s p e c t r a o f 2 - a c e t y l p y r r o l e .

Page 299: Instrumental

282

,%m : ME'!~YLI'YR~I~ (E.I.) For~u]e bru~ : C5 H6 ~ (P.M. - g4 ) Origine ' FRUC.-UnLI~ (M~ILL~RD)' UERMIM et aI,B.S.C.F.,4,S@1%9~,I987. II(a : 818 II(p : 126B DII( : 458 Re~erence : 8" 8

i

l

"t 4

I 0 I ~ 5D

' ) i i i t i i I , , ~ , . ~ ; ; ; ~ ~ , i i

Spec'Lre en impact elecieonique ' 94(188) 67 (5B), 39 (2B), 53 (19), ,t2 (15), 43 (14), 95 (11), 41 (1B), BB (4)

Morn : tI~HYLI'YR~I HE (P. C. I./NH3) Fo~ule b~te : C5 H6 M2 (P.M. : 94 ) Ori9ine : FRUC.-~JALIMU~ADORI):UERMIM et aI.,B.S.C.F., 4,6BI-694,198?. II(a : B18 II(p : 1268 Oil( : ' ] 58 Re~eeence : 8: 8

:oo i

J

:~ ! I

i i I I i i I i i i i I i i i ~ i i ~ i i i i 20 ~0 60 $0 I00 I~0 1~0 1~0 150 200 -'20 ~.0 ~r

95(188) 52 (6)

F igu re13 . El and P C I / N H 3 m a s s spec t ra of m e t h y l p y r a z i n e .

Page 300: Instrumental

: O O T

t I

.:,~

:~

: 2,5--DINETIfi'~AZiME (E.I,) Fomule b~'ute ' C6 H8 M2 (P,II, = 188 ) O,',!~ine : FHUC.-L:~LI,"IE (.,-11aDOHI);'JE~!M et al. ,H.S.C.F., u 681-694, I.o87. IRa : 918 l}(p : IL?.B ])11( : qlB Reference : 8: 8

!l'

'-3"3 -

i" t ~ ' , i ~ 'I" ~ t i I ~i i ' i i I i ', i ! i i i I

0 .~0 .tO r .~0 100 :20 :~0 "t;O "gO 200 2~0 ~*'0 2~;0

Spec+.re en impact elec+.roniclue ' a,2(188) 1BB (97), 39 (33), B1 (12), 189 (7), 52 (5), 41 (4), 43 (3), BB (3) 66 (2)

Horn : Z,5--DlrlETHYL~P, RZIME (P,C.I . /~3) For~ule brute: C6 H8 M2 (P.M. : 188 ) Origine : FRUC.-~JAL]ME(AII~ORI);UERM]M eL aI.,B.S.C.F.,4,691-694,198?. I]{a = 91t] II(p = 1321] DIK = 418 P, ef'erence = 8: 8

~0"-

20

. .'rt'.

I I I i 1 1 i I i i i i i ! t , i i i i i t i

2 8 3

0 20 '~r ~0 ~0 ;00 i20 "~0 L~O ;~0 200 220 2:0 2~0

109(180) 52 (3 )

F i g u r e l 4. El a n d P C I / N H 3 m a s s s p e c t r a o f 2 , 5 - d i m e t h y l p y r a z i n e .

Page 301: Instrumental

284

:I1 -., , .: j I

I 1 I

0 ?O 10 I 0 80 :QQ :tP 150 IT0 110 :3L 121 110 160

Spectre en impact electronique : 18888(188) 42 (961, 48 (571, 39 (481, 67 (81, 189 (81, 41 (61, 66 (51, 52 (31 187 (31

Hm : 2,6-DIHETWLPI~INE (P.C.I.RR13) Fomule brute : Cb H8 ti2 Origine : FRUC.-VILIHE(#1ADOAI ):VEININ et al.,B.S. C.F. ,4,681-b84,1987. IKa = 895 IHp = 1325 DIK = 4 3 Reference = 8: 8

( P . H . = 189 1

189( lea 1 52 (41

Figure 15. El and PCI/NH3 mass spectra of 2,6- dimethylpyrazine.

Page 302: Instrumental

285

Horn: Z,3-DItlL31~LPY,.~IHE (P.C.I./HH3) Fo~ule breie : CG H8 h?, (P.M. = 188 ) Or;,gine ' FRUC,-UAL!HE(~'I~DORI);UE~IH ei aI.,B.S.C.F.,4,681-694, !987. l~a : 988 IKp : 1348 Dll( = 4~8 ReFerence = 8: 8

J

~0" 52

I ~ I ) - I i ~' '~"| i ~ i " ' , ' l ~ ! " ' i , ')"~ i i i t 1 i '1"'

0 :,0 1.0 60 A.O :,)0 :.') :~,3 :~0 :*.0 2)0 :~0 ~0 ~0

189(188) _

52 ('t8), 182 (14)

H~ ' 2-~THYL-3, S(or3, 6)-DIM~/LIX/Pd~ZI HE (P. C. I./HH3) Fomule brute ' C8 HI2 H2 (P.M, = i36 ) Origine ' FI~C.-UALIHE(~I~I)ORI ),UEI~IIM eL a I . ,B.S.C.F. ,4 ,681-694,1987. IKa : 18fi8 I](p : 1478 DI}( : 418 Reference = 8: 8

1 i i ' I i i' ~ i " ! i 'i i i 1 t i I i t I I i i "1 I I I 0 20 IO gO ~0 IO0 :20 '.~,0 igO J,$O 200 ~0 210 250

137(188) 52 (281, 138 (18)

Figure 16. PCI/NH 3 mass spectra of 2,3-dimethylpyrazine and 2 - e t h y l - 3 , 5 ( o r 3 , 6 ) - d i m e t h y l p y r a z i n e s

Page 303: Instrumental

286

Mo~ : TRIMETH%I~'R~I,NE (E,I.)

~,,'i~i~e FRUC.-/P.i.iHE <~:(:..~':U~')HIII e! ~I 8.8 C.F.,a.,6BI-69a.,.,~?. iHa = 1888 ll~p- 1~89 DIN = 480 Re.;'erence = O: 8

i

"1

40"

I , , . l J

> i i i i I ; i i ~ : , i . . . . . ~ ; ' - i

Spectre on i~pac~ electronique ' 4Z(188) 122 (G4), 39 (21), 81 (15), 48 (12), 43 (G), $3 (6), 123 (S), 88 (2) 66 (Z)

Non' TRIMPI'HYLPYR~I HE (P.C.I./NH3) Fo~ule brute ' C? H18 N2 (P.M. : 122 ) Origine ' FRUC.-UALINE(~ADORI );UERM!M et al.,B.S.C.F., 4,581_694,1~?. I ~ = 1888 I,~p = 1"!88 Dig = 488 Reference = 8' 9

)0

+0"

, ! ~' i i i ) t i i " i i i i I i i i" ~ ' : i ~ i' I ' i i ~ ] ..... 0 20 ~0 ~0 30 !00 ',~0 '.~0 '.~0 180 ~00 ~0 2+0 ~0

123(169) $2 (6)

F i g u r e 1 7. E l a n d PCI/NH 3 m a s s spectra o f trimethylpyrazine.

Page 304: Instrumental

287

For~uie 5r,~%e : C,7 HIB H2 (P.PI. = 122 )

IXa = 995 ]Xp = 1385 D]}( = 398 ~eFe,,'ence = 8: 8

:o"

.,I. &,.

|

!,i +) ,"~+ i

�9 . �9 , i , ! i i , : I , " i " i ! i . ~

S p e c ~ : t ' e e n ~ p a c ' l ; e l e c % , " o n i q u e ' 1 2 1 ( 1 8 8 ) 122 (75), 39 (3G), 56 (24), 9,t (15), 42 (1']), 54 (11), 48 (18), 41 (7) 66 (4)

Ro~ ' Z-~L-5~L~B~I hE(P. C. I./HH3) For~le bru%e ' C7 H10 R2 (P.M. = 122 ) Origine ' FIIUC,~ALIHE(AIIADOR] );UERH]H e% aI.,B.S.C.F. ,4,681-694,19117. IKa- 995 IXp- 1385 Dig- 398 ReFerence- 8' 8

~0"

-H I

' i '~ t"

i i ~ i ! i i ' I i : i J ~ i i 1 t i t i I i ~

123(188) 52 (12), 121 (9)

Figure 18. El and PCI/NH 3 mass spectra of 2-ethyl-5-methylpyrazine.

Page 305: Instrumental

288

Nora : 2-1SOI]UTYL-5-t~,I~lX/R~ZI HE (E. I. ) Fo~ule brute : C9 HJ.4 H2 (P.M. = 4.58 ) Origine'FR~.-URLtNE (~..~DOi]I);~JERff!M eL aI,B.S.C.F.,4,~!-69~,1987.

~ , 0 0 _ . , ;~.

I ..,., - ,

t ,

~ I i ; i" i i i 1 i I i ~,

0 20 1t0 gO ~.0 I~O "29

Spectre en impact electroniclue '. 188(188) 39 (28), 135 (14), 88 (2)

: l i I I I i ' i i ,

41 (11), 42 (9), 158 (9), 189 (8), 66 (7), 149 (4)

Rm : Z-ISOBU~,L-5--I1D}h'Lh'Rt~]ME {P.C.I,/HH3) Fo~ule brute: C9 H14 H2 (P.M, = 158 ) Otigine : FRUC.-~JAL]HE(~ADORI);UERN]N et a|. ,B.S.C.F.,4,681-694,1987. IRa = 8 l](p = 1498 DIi( = B Reference = 8: 8

',09

~0"

~0

'~ i ~52

I t I I t ' i ] 2 i ~ . I i . I i I i I i I I i

0 :20 40 g0 80 :00 120 I.~..1 ;E;0 180 ~'.00 ~.20 2,0

151(181]) 152 (1B), 52 (9), 188 (8)

,~go

F i g u r e 19. El a n d P C I / N H 3 m a s s s p e c t r a of 2 - i s o b u t y l - 5 - m e t h y l p y r a z i n e .

Page 306: Instrumental

289

Morn ' 2- I SOBLITYL-H(or 6 ~'IL"]'HYLI'YR~I ME (E. I. ) F•mu!e brute' C9 H14,42 (P.M. : 158 )

' ~'RI'C ' ! T l I ,~ ' 2 O~'ig~ne ,.,~,.. C.F ,4,GBI-594,:.BT. IRa : B !X~ : I~@8 DI]( : 8 Re~e,,'ence : 8: 8

: . ) ) ,,

i

'~ )i i i 1 L i I i i I ' j ', i i I I I i i I I i :

Spectre en ~mpac~ e|ec+.ronique ' 188(188) 135 (13), 39 (13), 67 (18), ,t3 (9), 189 (B), 158 (5), 149 (4), 93 (4) 94 (3), B8 (2)

Norm ' 2-ISOBb'l~L-3(or 6)-METH%PYR~INE (P. C. I./NH3) For~ule brute ' cg H14 M2 (P.M. : 1SB ) Ori9ine ' FROC.-~3ALINE(~L~DORI );VERNIN et al . ,B.5. C.F., 4,681-694,1987. I}(a : 8 I}(p : 15B8 DII{ : B Reference : B: 8

"3) i

,~ i

! 1~2 i 07 i I ! i l' I i i i i :i' i i i" I I l " i i i i i t i 20 110 ~;0 90 :00 :20 ',~,0 :~0 1~0 200 220 2~0

151(188) 152 (11) , 52 (9 ) , 188 (9)

Figure P.O. El and PCI/NH 3 mass spectra of 2-isobutyl-3 (or 6) rnethylpyrazine.

Page 307: Instrumental

290

, , - . - ~ o v ~ ; ~ , - , , , 5 ( o r 3,o,'-~,ur,~nzLr~,'~,"~',',r, ( E , | ) Fomule b r u t e ' C18 H16 H2 (P.M. = 164 ) Oeigine ' F~I~.- 'JAL]~ (~r'~DORI);UE~.HiN et al. :8 .S.C.F. , ~.,~.91-69a., 1987. I~a : 8 Z]~.~ : 1538 DiK : 8 ?.es : 8: 8

~,) -

0 '

0

i .~,~ !! . . . . ,,

i i 1 i ' , ; :, , , i z , I i i t i i I i

-'r

Spectre en impact electeonique ' 122(181]) 42 (19), 39 (17), 149 (11), 123 (!8), 121 (7), 164 (6), 163 (4), 187 (3)

188 (3), 66 (2), 67 (2), 94 (1), 95 (1)

M~' 2-1SOB~L-3,5Cor 3,6~DIM~L~R~IHE (P,C,I,/HH3) Fomule brute ' C18 H16 H2 (P.M. : 164 ) Oeigine ' L~UC.-~JALINE(~ADORI);UERMiN et a I . ,B .S .C.F . ,4 ,6B1-694, lgBT. ] Ka - 8 I Kp - 1538 DI ]( - 8 Refez'ence - B: B

,.,),)

r

,~ i )

L E ' i ~

~ i I I i i ~ i ~ , ~ , ' ~ i i i i i ] i i i

o :.o ~o ~o so :oo ::o :.,o :~o :~o .'oo =:o ~:o :~o

165(188) 166 (11), 122 (8), 52 (3)

Figure 21. El and PCI /NH 3 mass spectra of 2- isobutyi-3,5 (or 3,6)

d imethylpyrazine.

Page 308: Instrumental

291

Nora ' ALLYLtlET~L DISULFIDE (E,I,) Fomule br~te : C4 FIB $2 (P,li, : !2B ) Orioine : GARLIC E.O.;UZP,~IM et aI,,PLAMT.,fl ~ . , I~6,96- !BI , IXa : 8 !Rp = ~38 DI~ = 8 Re.~erence = B:

q ..]

' I !,,

i i i k i i i i ~ I i' i i i i i i i i i ~ i - i

~~ en ~pacs elec~ronique ' 41(:[B8) 128 (51), 39 (24), 44 (17), 53 (13), 72 (6), ?8 (6), 121 (3), 122 (3)

Morn ' ALLYI/1ETHYL DISULFIDE (P.C.I./i-C4HIB) FoPmule brute : C4 H8 S2 (P.M. -- 128 ) Origine : GARLIC E.O.;UERNIN et aI.,PLAIfrA MEI).,19B6,9fr1111. I Xa = 8 I](p = 1238 DI]( = 8 Reference = 8:

'~176

~ I i I l I I I i I , I ~ i l I I I I i i i ~ i I

121(1BI]) !21] (2B), 73 (21]), 176 (B), 55 (4)

Figure 22. El and PCI/i-C4H 10 mass spectra of allylmethyl disulfide.

Page 309: Instrumental

292

Hm ' DI~LL~L DISULFIDE (E. I . ) Fo~ule brute ' C6 HiB $2 (P.M. : 1~.6 ) Ori9ine ' ~RLIC E.O. 'UE~IIN a ML:TZGF~,E.O. ~ W~.XES, S P R I ~ L~L~,1991, 99-138. ira = IIZ8 I~(p = 1436 PI~( : 316 ib~erence = 8' 8

',,)o

.:' c , -

T~)-

l ~.).-

~o

I , ! ! , I l t I 1 [ 1 i i t ~ t i t I I i I ; i i i

Spectre en impact e l e c ' L r o n i g u e ' 4 1 ( 1 8 8 ) 45 (19), BI (14), 113 (7), 146 (5), 73 (6),

~ 0 ~00 220 ~ 0 2~3

85 (5), 79 (5), 1B3 (3)

Nero ' DIRLLYL DISULFIDE (P.C.l./i-Cah118) Fomule brute ' C5 H18 $2 (P.M. : 146 ) Origine ' G;~RLiC E.O. ;UE~IN ~ ML'~GEJLE.O.a ~ES, SPRIHGF~ UERL~G, 1991, 99-138. ]Ka : 1128 I~(p- 1436 DIX - 316 Res : 8: B

"-~)0 ,:

:,0"

%0"

I !:'3

l g

. il r , ,

o I i ~ " i i i " i i' i ~ i i ! t ] I i I i' ~ i I i i 0 20 ~0 60 80 !00 :20 I~0 :GO ~.$0 200 2-~0 ~ 0 2~0

147(188) 73 (19), 146 (15), 43 (11), 283 (11), 115 (11), 55 (11), ~ (11), 149 (11) 45 (7), 185 (7), 89 (7), 148 (7), 91 (3)

F i g u r e 23. F:l and PCI/i-C4H 1 0 mass spectra of diallyl disulfide.

Page 310: Instrumental

293

Num' t%LLYIXIETHYL DISULFIDE (N.C.I./OH-) Fomule beute ' C4 H8 $2 (P.ti. = 128 ) Oeigine ' GARLIC E.O.;UERNIN et aI.,PLANTA tlED.,1986,9fr181. IRa = 8 Igp = 123B DI R = 8 ?,efeeence - 8:

o,j j , , ~ , j 1

7

I i I I i i t I' I i I t ; i i I I 0 20 qO 60 $0 100 IXO ~-~0 :60 i~O ~.00 ~0 ~0 ~:0

72(188) 79 (68), 73 (58), 44 (58), 47 (24)

b ' DlfiLLYL DISULFIDE (N.C.l./~-) Fomule brute ' C6 H18 SZ (P.M. = 146 ) Oeigine ' GARLIC E.O.;UERNIN & ~GE,q,E.O.& ~/~KES, SPRII4GER UERL~G,1991,99--I~. IKa = 1128 IKp = 1436 DII = 316 Refeeence = B' B

'~176 I -~ 73

. . . . . . . . _ i

~ i ; i i " ' i t t I 4 1 i i i i ~ "~ i ' i i i i I t 0 20 110 60 ~0 %00 :20 ~.'+0 160 I~0 ~00 ::0 2'+0 260

72(188) 47 (77), 73 (58), IB5 (45), 75 (36), 44 (31)

Figure 24. NCI/OH" mass spectra of allylmethyl disulfide and diallyl disulfide.

Page 311: Instrumental

294

C" -S-S-CH=CH-CH z CHz=CH-CHz-S-S-CH-CH= H 2 ~ CH2= m-CH 2

-HOfH

CHz=CH-CH 2- S t']- S_C'~H :CH.~'H ~ ~ ,CH-CH-CH 2.,. CH2=CH-CH 2- S-S'-

HO-

CH2=CH-CH2-S-S:-

CH / % - CH ~ CHz,-CH-CH 2-S:- + S CHz=CH-CH2-S~ S .~ /

[(1L5) ! -:CH2

CH / % CH \ /

CH2

CH2=CH-CH2-S -CH=CH-CHz:------,~ ;S-CH=CH-CHz:-

lci- il I721 Scheme 2. Formation of ions at m/z : 145, 105, 73 and 72, of diallyl disulfide NCI(OH') (101,102).

M i s c e l l a n e o u s t e c h n i q u e s

Various coupling techniques in mass spectrometry have also been described, in particular: - Capillary GC-MS and capillary GC-FTIR upon El and CI (156, 157) - MS/MS (104) - SIMS stable isotope (13C) mass spectrometry applied to o~- and 13-ionones extracted from raspberry fruit, wine and raspberries (158). - MDGC - IRMS (multidimensional gas chromatography (159). Isotope ratio mass spectrometry (159). All these techniques have considerably enlarged the potential of mass spectrometry in the analysis of flavors and fragrances (160).

Page 312: Instrumental

295

6. CONCLUSIONS

Quasimolecular masses obtained by positive chemical ionization and negative chemical ionization complement the electron impact data. These techniques make it also possible to obtain information about the geometry of stereoisomers such as carveols, isopulegols, and linalyl oxides.

Negative chemical ionization (NCI, OH') is better suited for analysis of terpenoid alcohols and esters, whereas positive chemical ionization (PCI, isobutane) is a technique used for carbonyl compounds, ethers, and sulfur compounds.

Positive chemical ionization (ammonia) is also a good analytical method for essential oils, especially for their monoterpene and sesquiterpene components. Also the chromatographic data (e.g., Kovats indices) should be regarded as an additional means of identification.

Acknowledgements

The authors wish to thank Mrs G. M.F. Vernin and Mrs. R.M. Zamkotsian for their technical assistance, the Central Analitical Services of Lyons for the mass spectra obtained by the chemical ionization techniques, and Pr. J. Metzger for fruitful discussions.

7. REFERENCES

10a

Maarse H, Belz R eds. Isolation, Separation and Identification of Volatile Compounds in Aroma Research, Akademie-Verlag, Berlin: 1981. Witte L. In: Linskens HF, Jackson JF, eds. Modern Methods of Plant Analysis Springer Verlag, Berlin: 1986; 3: 134-145. Masada Y, Analysis of Essential Oils by GC-MS, Wiley, New York: 1976. Lawrence BM, Essential Oils, Allured Publ. Corp, Wheaton IL:1976-1978; 1979; 1980; 1980-1987. Van Straten S ed. Volatile Compounds in Food, Central Institute for Nutrition and Food Research TNO, Ultrechtseweg 48: PO Box 360, The Netherlands,1977; 1979; Walradt JP. In: Theimer ET, ed. Fragrance Chemistry: the Science of the Sense and Smell, Academic Press, New York: 1982; 575-615. Vernin G, ed. The Chemistry of Heterocyclic Flavouring and Aroma Compounds, Ellis Horwood Publ. Chichester: England, 1982. Srinivas SR. Atlas of Essential Oils, Wiley, New York: 1986. Maarse H, Visscher CA, 6th ed. Volatile Compounds in Food. Qualitative and Quantitative Data, TNO-CIVO Food Analysis Institute, Zeist: The Netherlands, 1989; 1:2: 3: Maarse H, Boelens MH. In: Bessiere Y, Thomas A.F. eds. Flavour Science and Technology, The TNO Data Base, Volatile Compounds in Food: Past, Present and Future, Wiley J. and Sons, New York: 1990; 275-278.

Page 313: Instrumental

296

10b

11 12 13

14 15 16 17 18 19

20 21

22

23 24

25 26 27 28 29 30

31

32 33

34

35

36

37

38

Maarse H, Visscher CA, eds. Willemsens LC, Boelens MH, co-eds. Volatile Compounds in Food. Qualitative and Quantitative Data, An Essential Guide for Trade and Industry, TNO Nutrition and Food Research, Ultrechtseweg 48 PO Box 360, Zeist: The Netherlands, 6th ed. 1989: 3rd Suppl. 1992. Reineccius GA. Instrum Methods Qual Assur Foods 1991; 45: 67-81. Mosandl A. J Chromatog 1992; 624: 267-292. Schmid JP. In: Bessiere Y, Thomas AF eds. Flavour Science and Technology, Wiley J. and Sons, New York: 1990; 239-254. Ryhage R, Von Sydow E. Acta Chem Scand 1963; 17:2025-2035. Thomas AF, Willhalm B. Helv Chim Acta 1964; 47: 475-488. Von Sydow E. Acta Chem. Scand 1963; 17: 2504-2512. Von Sydow E. Acta Chem. Scand 1964; 18:1099-1104. Von Sydow E. Acta Chem. Scand 1965; 19: 2083-2088. Von Sydow E, Anjou K, Carlson G. Archives of Mass Spectral Data, Swedish Institute for Food Preservation Research Fack, Gothenburg, S. 1970. Hirose I. Shitsuryo Bunseki 1967; 15: 162-168. Hayashi S, Sato H, Hayashi N, Okude T, Matsuura T. J Sci Hiroshima 1967; 31 : 217-231. Yukawa Y, Ito S. eds. Spectral Atlas of Terpenes and the Related Compounds, Hirokawa Publ. Co. Tokyo: 1973. Moshonas MG, Lund ED. The Flavour Ind 1970; 375-378. Jennings W, Shibamoto T eds. Qualitative Analysis of Flavor and Fragrance Volatiles by Glass Capillary - Gas Chromatography, Academic Press, New York: 1980. Enzell CR, Ryhage R. Ark Kemi 1965; 23: 367-399. Enzell CR. Tetrahedron Letters 1966; 2135-2143. Enzell CR. Ark Kemi 1967; 26: 425-434. Enzell CR, Ryhage R. Ark Kemi; 1967; 27: 213-229. Enzell CR, Wahlberg I. Acta Chem Scand 1969; 23: 871-891. Enzell CR, Appleton RA, Wahlberg I. In: Waller GR, Dermer OC eds, Terpenes and Terpenoids, Wiley Interscience. New York: 1972; 311-406. Enzell CR, Wahlberg I. In: Waller GR, Dermer OC eds, Terpenes and Terpenoids, Wiley Interscience. New York: 1980; Suppl 1:311-406. Enzeil CR, Wahlberg I, Ryhage R. Mass Spectrom Rev. 1984; 3(3): 395-438. Tucker AO, Maciarello MJ. In: Charalambous G. ed. Spices, Herbs and Edible Fungi, Elsevier. Amsterdam: 1994; 34: 605-656. Mass Spectral Research System. 1974. Users' Manual; US Environmental Protection Agency, Office of Planning and Management. 1974. Middledich BS. ed. A Guide to Collections of Mass Spectral Data. American Society for Mass Spectrometry. 1974. Stenhagen E, Abrahamson S, McLafferty FW. eds. Registry of Mass Spectral Data, Wiley and Sons, New York: 1974. Cornu A, Massot R. Compilation of Mass Spectral Data. Heyden and Sons Ltd. London: 1966; 1967; 1971;1975. Heller RS, Milne GWA. EPA/NIH Mass Spectral Data Base, US Government Printing Office, Washington: DC 1978.

Page 314: Instrumental

297

39

40

41

42 43 44

45 46

47

48

49

50 51

52

53

54

55

56

57

58

59

Heller SR, Milne GWA. EPA/NIH Mass Spectral Data Base, US Government Printing Office, Washington: DC 1980; 1983; 1987. Craveiro AA, Alencar JW. 178th ACS National Meeting, paper 70 (AGFD) Div. Washington: DC 1979. Craveiro AA, Rodrigues AS, Andrade CHS, Matos FJA, Alencar JW, Machado MIL. 8th International Congress Essential Oils, Publ. Fedarom, Cannes-Grasse: 1982; 241-254. Petitjean M, Vernin G, Metzger J. Ind Aliment Agric 1981;9: 741-751. Petitjean M. These Sciences, Universit~ d'Aix-Marseille 3,St-J~rSme: 1982. Petitjean M. Vernin G. Metzger J. In:.Charalambous G, Inglett G eds. Instrumental Analysis of Foods: Recent Progress. Academic Press. New York: 1983; 1 : 97-124. Vernin G. Petitjean M. Metzger J. Parf Cosm Ar6mes 1983; 51: 43-52. Vernin G. Petitjean M. Poite JC, Metzger J, Fraisse D, Suon KN. In: Vernin G, Chanon M. eds. Computer Aids to Chemistry. Ellis Horwood Publ. Ltd. Chichester: 1986; 7: 294-333. Vernin G, Petitjean M, Metzger J, Fraisse D, Suon KN, Scharff C. In: Sandra P, Bicchi C. eds. Capillary Gas Chromatography in Essential Oils Analysis. Huethig Verlag, Heidelberg: 1987; 287-328. Mass Spectrometry Data Centre: Eight-peak Index of Mass Spectra. The Royal Society of Chemistry Nottingham: 1983. Mass Spectrometry Data Centre: Eight-peak Index of Mass Spectra. The Royal Society of Chemistry (3rd ed.) Nottingham: 1986. Finnigan Mat, Library Compilation (38.000 entries) San Jose CA : 1984. Hewlett Packard. HP 59943A/PBM Data base. Copyright Hewlett Packard and Co: 1988. Chien MJ. In: Lawrence BM, Mookherjee BD, Willis BM. eds. Flavors and Fragrances: A World Perspective. Elsevier. Amsterdam: 1988; 923. Wiley and Sons, CD Rom System, DC Rom System for Mass Spectral Data New York: 1988. De Brauw N, Bouman J, Tas AC, La Vos GF. Compilation of Mass of Volatile Compounds in Foods. Central Institute for Nutrition and Food Research, TNO Zeist, The Netherlands: 1981. De Brauw N, Bouman J, Tas AC, La Vos GF, Gromberg LG. Compilation of Mass Volatile Compounds in Foods. Central Institute for Nutrition and Food Research, TNO Zeist, The Netherlands: 1988. McLafferty FW. Wiley/NBS Registry of Mass Spectral Data. 4th ed. Wiley J. New York: 1988. McLafferty FW. Stauffer DB. eds. The Wiley/NBS Registry of Mass Spectral Data. Wiley J. and Sons. New York 1988; idem. J. Wiley Interscience Publ. New York: 1989. Henneberg D, Weimann B, Joppek W. MPI Library of Mass Spectral Data. Max Plank Institut fur Kohlenforschung. M01heim Germany: 1989. National Institute of Standards and Technology. NIST/EPA/NIH Mass Spectra Data Base. PC Version 4.0, NIST, 62.500 entries Gaithersburg Ma: 1992.

Page 315: Instrumental

298

60

61

62 63

64 65

66

67

68 69 70

71

72 73 74

75a 75b

76 77 78 79

80

81 82 83 84

85

86 87

National Library of Standards. Mass Spectra. US Department of Commerce National Bureau of Standards NBS. National Standard References Data Systems NSRDS, EPA/NIH Mass Spectral Data Base. 1992: 1:- 4. Mc Lafferty FW. Wiley Registry, Benchtop/PBM Version 3.0, Palisade Corp. Newfield, New York: 1992. Umano K. Fragrance J 1992; 20(1): 27-32. Budzikiewicz H, Djerassi C, Williams D.H. Mass Spectrometry of Organic Compounds Holden-Day Inc: 1967. Budzikiewicz H. Mass Spectrom Rev 1991; 10(6): 519-522. Merrit L. Mac Even CN. eds. In: Practical Spectroscopic Series. Part A. Mass Spectrometry. Dekker M Inc. New York: 1979: 3. Porter ON, Baldas J. Mass Spectrometry of Heterocyclic Compounds Wiley Interscience, New York: 1971. Lange G, Schuitze W. In: Brunke J ed. Progress in Essential Oils Research De Gruyter and Co, Berlin: 1986; 597-617. Kovats E. Helv Chim Acta 1958; 41: 1915-1932. Van den Dool H, Kratz PD. J Chromatog 1963; 11: 463-471. Albeiges J, Guardino X. J High Resolut Chromatogr Chromatogr Commun 1985; 8(6): 301-302. Shibamoto T. In: Sandra P, Bicchi C. eds. Capillary Gas Chromatography in Essential Oils Analysis, Huethig Verlag, Heidelberg: 1987; 259-274. Ettre LS. Chromatographia 1973; 6(11): 489-495. Haken JK. Adv Chromatogr New York 1976; 14: 367-407. Saeed T, Redan G, Sabdra P. J High Resolut Chromatogr Chromatogr Commun 1979; 2: 75-76. Alencar JW, Craveiro AA, Matos FJA. J Nat Prod 1984; 47: 890-892. Alencar JW, Craveiro AA, Matos FJA, Machado MIL. Quimica Nova 1990; 13(4): 282-284. Perry NB, Weavers RT. J Chromatogr 1984; 284: 478-481. Yamada H, Harada K, Nakamura S, Mihara S. J S C C J 1987; 21 (1): 30-35 Libbey L.M. J E O R 1991;3: 193-194. Teranishi R, Buttery RG, Stern DJ, Takeoka G. In: Bessiere Y and Thomas AF eds. Flavour Science and Technology Wiley J and Sons New York: 1990; 267-278. Kovats E. In: Giddings JC, Keller RA eds. Advances in Chromatography Dekker M New York: 1965; 119-127. Wehrli A, Kovats E. Helv Chim Acta 1959; 42: 2709-2736. Andersen NH, Falcone MS. J Chromatogr 1969; 44:52-59 Andersen NH, Syrdal DD. Phytochemistry 1970; 9: 1325-1340. Andersen NH, Syrdal DD, Lawrence BM, Terhune SJ, Hogg JW. Phytochemistry 1973; 12: 827-833. Andersen NH, Bissonette P, Liu CB, Shunk B, Ohta Y, Tseng CLW, Moore B, Huneck S. Phytochemistry 1977; 16(11): 1731-1751. Erdey L, Takacs J, Szalanczy. J Chromatogr 1970; 46: 29-32. Majlat P, ErdSs Z, Takacs J. J Chromatogr 1991; 91" 89-103.

Page 316: Instrumental

299

88

89

90

91 92

93 94 95

96

97 98

99

100

101 102

103

104

105

106

107

108

109

Swigar AA, Silverstein RM. In: Aldrich Chem Co, Monoterpenes, Infrared, Mass 1H NMR and 13C NMR Spectra and Kovats Indices, Milwaukee Wl 1981. Sadtler Research Laboratories. The Sadtler Standard Gas Chromatography Retention Index Library Division of Bio-Rad Laboratories Inc. Philadelphia: 1985. Ramaswami SK, Briscese P, Garguillo RJ, Von Geldren T. In: Lawrence BM, Mookherjee BD, Willis BJ. eds. Flavors and Fragrances" A World Perspective, Elsevier, Amsterdam: 1988; 951-980. Davies NW. J. Chromatogr 1990; 503: 1-24. Mihara S, Masuda H. J Chromatogr 1987; 402: 309-317. J Agric Food Chem 1988; 36: 1242-1247. Ames JM, Elmore JS. Flavour and Fragrance J 1992; 7: 89-103. Boniface C, Vernin G, Metzger J. Analusis 1987; 15: 564-568. Guy I. DEA, Facult~ des Sciences Marseille S-J~r6me, 1993. Contrat ANVAR J 92 07063UJJ. Hirvi T, Honkanen E, Instrumental Analysis of Foods Academic Press Inc. New York: 1983; 85-95. Hendriks H, Bruins AP, Biomed. Mass Spectrom 1983; 10(6): 377-381. Vernin G, Metzger J, Suon KN, Fraisse D, Ghiglione C, Hammoud A, Parkanyi C. Lebensm wiss u Technol 1990; 23: 25-33. Frey C. In: Lawrence BM, Mookherjee BD, Willis BJ, eds. Dev Food Sci Flavors and Fragrances: A World Perspective, Elsevier, Amsterdam: 1988; 18: 517-524. Vernin G, Metzger J, Fraisse D, Suon KN, Scharff D. Perfumer and Flavorist 1984; 9:71-86. Vernin G, Metzger J, Fraisse D, Scharff C. Planta Medica 1986; 2: 96-101. Vernin G, Metzger J. In: Linskens HF, Jackson JF. eds. Modern Methods of Plant Analysis New Series Essential Oils and Waxes. Springer Verlag Berlin: 1991 ; 12:99-130. Vernin G, Boniface C, Metzger J, Fraisse D, Doang D, Alamercery S. in: Charalambous ed. Frontiers of Flavors Elsevier, Amsterdam: 1988; 655- 685. Busch KL, Glish GL, McLuckey SA. Mass Spectrometry/Mass Spectrometry Techniques and Applications of Tandem Mass Spectrometry VCH Publ. New York: 1988; 21. HObschmann HJ, Schubert R. In: Brunke EJ ed. Progress in Essential Oil Research De Gruyter and Co, Berlin 30: 1986; 643-648. Stafford GC Jr, Kelly PE, Syka JEP, Reynolds WE, Todd JFJ. Int J Mass Spectrom Ion Proc 1984; 60-85. Lauris JN, Cooks RG, Syka JEP, Kelley PE, Stafford GC, Todd JFJ. Anal Chem 1987; 59(13): 1637-1685. Adams RP. Identification of Essential Oils by Ion Trap Mass Spectrometry Academic Press Inc. San Diego: 1989. Adams RP. In: Linskens HF, Jackson JF. Modern Methods of Plant Analysis New Series Essential Oils and Waxes. Springer Verlag, Berlin: 1991; 12: 159-173.

Page 317: Instrumental

300

110 111

112 113 114

115 116 117

118 119 120 121 122 123 124 125

126 127 128

129

130 131 132

133a 133b 134

135

136 137

138

139

Adams RP, Weyerstahl P. J E O R 1992; 4: 197-200. Harrison AG. Chemical Ionization Mass Spectrometry CRC Press Inc. Boca Raton FLO: 1983. Munson MSB, Field FH. J Amer Chem Soc 1966; 88(12): 2621-2630. Richter WJ, Schwarz H. Angew Chemie Int Ed Engl 1978; 17: 424-439. Rapp U, Hoehn M, Kapitzke C, Dielman G. In: Baltes W ed. Recent Developments in Food Analysis Verlag Chemie Gmbh, Weinheim New York: 1982; 162-169. Westmore JB, Auladdin MM. Mass Spectrom Rev 1986; 5: 381-465. Budzikiewicz H. Mass Spectrom Rev 1986; 5: 345-380. Bruins AP. In: Sandra P, Bicchi C. Capillary Gas Chromatography in Essential Oil Analysis, Huethig Verlag, Heidelberg: 1987; 329-357. Lias SG, Liebman JF, Levin RD, J Phys Chem 1984; 13: 695-808. Vairamani M, Mirza UA, Srinivas R. Mass Spectrom Rev 1990; 9: 235-258. Smith ALC, FH Field. J. Amer Chem Soc 1977; 99(20): 6471-6483. Jelus BL, Dalrymple DL, Michnowicz J, Munson B. 1978; 13: 163-166. Bruins AP. Anal Chem 1979; 51:967-972. Weinkam RJ, Lin HS. Anal Chem 1979; 51(7): 972-975. Budzikiewicz H, Busker E. Tetrahedron 1980; 36: 255-266. Knight DW, Knight ME, Rossiter M, Jones A, Games DE. Adv Mass Spectrom 1980; 8B: 1116-1126. Hourriet R, Stahl D, Winkler. Environm Health Perspect 1980; 36: 63-68. Hendriks H, Bruins AP. J Chromatogr 1980; 190: 321-330. Hadjieva P, Sandra P, Stoianova-lvanova B, Verzele M. Riv Ital EPPOS 1980; 62: 367-372. 1 lth IUPAC Int Symp on Natural Products. In: Marekov N, Ognyanov l eds. Izd BAN, Sofia: 1978; 2: 464-468. Bos R, Bruins AP, Hendriks H. In: Kubeczka KH ed. Atherische 5le Analytik Physiologie Zusammensetung, George Thieme, Stuttgart: 1982; 25-32. Williams AA, May HV. J Inst Brew 1981; 87: 372-375. Tabet JC, Fraisse D. Org. Mass Spectrom 1981; 16: 45-47. De Puy CH, Beedle EC, Bierbaum VM. J Amer Chem Soc 1982; 104: 6483- 6488. Fellous R, George G. Parf Cosm Ar6mes 1981; 41: 43-45. George G. Parf Cosm Ar6mes 1982; 43: 37-40. Winkler FJ, G(Jlacar OF, Buchs A. Anal Chem Symp Ser Recent Dev Mass Spectrom Biochem Med Env Research 1983; 8: 307-317. Fraisse D, Scharff C, Vernin G, Metzger J, 9th Int Congr Essential Oils Singapore: 1983; Essential Oils Technical Paper 1983; Vol 3: 100-120. Vernin G, Metzger J. Parf Cosm Ar6mes 1983; 52" 51-61. Jalonen J, Taskinen J, Gildewell C. Int J Mass Spectrom Ion Phys 1983; 46: 243-246. Sarris J, Etievant PX, Le Quere JL, Adda J. In: Adda J. ed. Progress in Flavour Research 1984 Proc 4th Weurmann Flavour Research Symposium Elsevier, Amsterdam: 1985. May HV, Williams AA. In: Adda J ed. Progress Flavour Research 1984 Proc 4th Weurmann Flavour Research Symposium Elsevier, Amsterdam: 1985.

Page 318: Instrumental

301

140a

140b 141 142

143 144

145 146

147 148a

148b

149

150

151

152 153

154 155

156 157

158

159

160 161

Einhorn J, Virelizier H, Gemal AL, Tabet JC. Tetrahedron Letters 1985; 26: 1445-1448. Doolittle RE, Tumlinson JH, Proveaux A. Anal Chem 1985; 57: 1625-1630. Jalonen J, Taskinen J. J Chem Soc Perkin Trans II 1985; 1833-1838. Koepsel M, Krempel A, Surburg H. In: Brunke EJ ed. Progress in Essential Oil Research De Gruyter W Publ Berlin: 1986; 241-248. Tabet JC. Tetrahedron 1987; 43: 3413-3420. Munson B, Feng TM, Ward HD, Murray RK. Org Mass Spectrom 1987; 22: 606-609. Lange G, Schultze W. Flavour Fragrance J 1987; 2: 63-73. Madhusudanan KP, Srivastava R, Kulsrhestha DK, Fraisse D. Org Mass Spectrom 1987; 22: 368-372. Lam KC, Deimzer ML. J Agric Food Chem 1987; 35: 1987. Lange G, Schultze W. In: Schreier P. ed. Bioflavour 87 De Gruyter W Publ Berlin: 1988; 115-122. Lange G, Schultze W. In: Schreier P ed. Bioflavour 87 De Gruyter W Publ Berlin: 1988; 105-113. Vernin G, Metzger J, Obretenov T, Suon KN, Fraisse D. Proc 10th Int Congr Essential Oils Fragrances and Flavors Washington DC: 16-20 Nov 1986. In: Lawrence BM, Mookherjee BD, Willis BJ. eds. Flavors and Fragrances: A

World Perspective Elsevier, Amsterdam: 1988; 999-1028. Badjah Hadj Ahmed AY, Meklati BY. Flavour and Fragrance J. 1988; 3: 13- 18. Schultze W, Lange G, Schmaus G. Flavour and Fragrance J. 1992; 7: 55- 64. Schultze W, Lange G, Schmauss G. J E O R 1992; 4(5): 497-510. Zupanc M, Prosek M, Dusan M. J High Resolut Chromatogr 1992; 15(8) 510-513. Lange G, Schultze W. Org Mass Spectrom 1992; 27(4): 481-488. Papageorgiou VP, Arguriadou N, Kokkini S, Mellidis AS. Chem Chron 1983; 12: 27-35. Smith SL. J Chromatogr Sci 1984; 22: 143-148. Herres W, Kubeczka KH, Schultze W. In: Brunke J ed. Progress in Essential Oil Research De Gruyter W and Co Berlin, New York: 1986; 507-528. Braunsdorf R, Hener U, Lehmann D, Mosandl A. Dtsch Lebensm Rundsch 1991; 87(9): 277-280. Nitz S, Weinreich B, Drawert F. J High Resolut Chromatogr 1992; 15(6): 387-391. Torrent A. Analusis Magazine 1992; 20(7): 66-70. Carceles M.F, Thesis Sciences, Nice-Sophia Antipolis University 1995.

Page 319: Instrumental

This Page Intentionally Left Blank

Page 320: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 303

GAS CHROMATOGRAPHIC TECHNOLOGY IN ANALYSIS OF

DISTILLED SPIRITS

Kevin MacNamara I and Andreas Hoffmann 2

'Irish Distillers Limited, Bow Street Distillery, Smithfield, Dublin 7, Ireland

2Gerstel GmbH, AktienstraBe 232-234, 45473 Mtilheim an der Ruhr, Germany

INTRODUCTION Aged distilled spirits constitute a complex mixture of some hundreds of flavour compounds in

an ethanol-water matrix. These flavour compounds, or congeners, originate from the original raw materials and the subsequent processes of mashing, fermentation, distillation and ageing, which together produce the final product. Complex interdistillate reactions between congeners are also an important part of the flavour scenario, and this is particularly important during the ageing phase in oak barrels.

Tables I and 2 outline the principle congener classes found in whiskey, cognac and rum together with an indication of compound numbers by class [1]. The naturally occurring relative concentrations of these compounds can vary from high mg/l to low ng/1. Each congener in turn has an odour intensity and flavour contribution which is determined not only by its concentration, but also its unique sensory threshold value. For this reason the most abundant congeners may be the most amenable to analysis, but the resultant quantitative information may have little relationship to the perceived flavour of the spirit. On the other hand this type of information does describe the gross structure of the spirit and is an important data base for ensuring process continuity and product authenticity.

Chemical Class Whiskey Cognac Rum

Hydrocarbons 7 15 38 Hydroxyl compounds 53 104 88 Carbonyl compounds 24 93 63 Carboxylic acids 35 43 30 Esters 79 195 115 Lactones 4 10 7 Acetals / Esters 21 43 76 O-Heterocyclics 7 23 41 N-Heterocyclics 28 10 23 Miscellaneous 11 10 16

TOTAL 269 546 497 Reproduced with permission from [11

Table 1. Number of volatile compounds, identified in whiskey, cognac and rum.

Page 321: Instrumental

304

Chemical Class Whiskey Cognac Rum

Aliphatic compounds 187 382 309 Aromatic compounds 42 79 88 Terpenoid compounds 5 52 36 Heterocyclic compounds 35 33 64

TOTAL 269 546 497 Reproduced with permission from [1]

Table 2. Number of volatile compounds, identified in whiskey, cognac and rum.

In an interesting study Salo [2] prepared a synthetic whiskey using purified individual congeners in accurately known amounts, and with levels based on gas chromatographic data obtained from a real whiskey. Odour threshold values were used to determine the relative odour intensity of individual aroma compounds, and aroma fractions of alcohols, esters, acids, carbonyl compounds and mixtures of these compounds. The results clearly showed that the contribution of the most abundant congeners to the total odour intensity is quite low. The alcohol fraction accounted for 70% and the acid fraction 11% of the total congener concentration, yet both together only contributed 7.5% of the total odour intensity.

In the light of these facts a commercial producer of distilled spirits needs a particular analytical strategy to service and satisfy various needs, which might include:

- Rapid, high-throughput direct analysis of the abundant congeners for production process continuity and authenticity information.

- Various sample preparation techniques for enriching trace congeners from the ethanol- water matrix. These can usually be divided into simple enrichment procedures or more elaborate investigative schemes giving enriched compound classes that also facilitate sensory information.

- Use of the trace congener information provided by investigative research to devise further high-throughput analytical techniques that make use of advances in modem GC technology and detection systems.

The previous discussion constitutes a basis for the thematic content of this chapter which is to review historical and present chromatographic approaches to distilled spirits analysis, and to explore the potential and application of modem GC technology in this area. The term "GC technology" has been chosen to emphasise an instrumental dimension in the sense that very successful analytical schemes can be constructed if the gas chromatograph is regarded as something more than an oven and a column. Cold capillary programmable injection technology, and static and dynamic headspace, and large volume liquid injections that exploit the cold injector can produce systems for efficient routine analysis of spirits as is, or after minimum sample preparation. Newer detection modes and technologies can be exploited for similar benefits resulting from sensitivity and specificity enhancements. Capillary columns of such different coatings, dimensions

Page 322: Instrumental

305

and phase ratios are now available that sample preparation schemes can be devised to make maximum use of these variables. The aim should be to tailer this technology to the nature and relative concentrations of the congeners and on this basis the following areas will be reviewed and explored.

Direct Injection: Review of various approaches using custom packed columns and modem capillary columns to profile the most abundant congeners without sample preparation. Use of specialised capillary injection techniques, especially in conjunction with mass spectrometric target selected ion monitoring, to extend the range of congeners that can be directly determined in the natural matrix. Introduction to a cooled injection system with programmable vaporisation as a universal capillary injection system.

Matrix Removal: Review of many of the approaches developed for this purpose ranging from simple solvent extraction, to multi-step combined extractive and instrumental schemes, which can give enriched subtractions with selective congener types. This gives an opportunity in turn to suit column selection (coating type and phase ratio) and detection strategy to individual congener groups.

Large Volume Injection: This is an important concept and technology for the future and has the potential to provide a natural link between data obtained from research investigations, and the need to produce rapid routine methods. If the compound contents of 500 pls of a simple extract can be transferred to the column, it offers the possibility of low-cost routine analysis of trace congeners. The fact that usually only 1-2 lal of complex extracts are used for analysis also represents an expensive waste of resources. Therefore compounds indicated as potential flavour contributors from classical multi-step sample preparation routes could be monitored by automated large volume injection of relatively simple sample extracts. The success of this technique relies on programmable injection technology with simultaneous solvent venting and retention of analytes of interest in the injector liner. The same cooling and venting properties of the programmable injector can be similarly exploited for large volume injection from either headspace or thermal desorption devices. In fact the design of these units can be greatly simplified when their operation involves a programmable injector.

Two Dimensional Chromatography: The separating power of single highly efficient capillary columns is in many cases not sufficient for complex subfractions and extracts obtained from distilled spirits. Very interesting selective sulphur and nitrogen traces are available but mass spectrometric identification of the compounds is often very difficult. The vastly increased separating power of serially coupled columns offers an efficient solution to this problem. Commercial apparatus is now available which allows two oven systems to be easily configured for computer controlled 2-dimensional separations, and quickly revert back to two independent gas chromatographs when not being used for this purpose.

There are many different approaches for the determination of abundant and trace congeners in distilled spirits. In many cases the apparatus and techniques are unique to the particular group or laboratory, and it can be difficult for other workers to reproduce the exact scheme adopted. This chapter also contains some procedures favoured by one of the present authors (K MacN), but a

Page 323: Instrumental

306

difference is that they are rooted as much as possible in a dialogue with a specialist instrument manufacturer, and are therefore based on commercially available systems. Finally much of the discussion and many of the examples centre around whiskey, but the methods and technology should be applicable to all distilled spirits.

DIRECT INJECTION The most abundant compounds present in distilled spirits are the fusel alcohols and fatty acid esters, together with acetaldehyde and its acetal. Fusel alcohols are produced in fermentation from amino acids via decarboxylation and deamination, while the esters are formed in yeast cells. Acetaldehyde is the most abundant carbonyl compound and its reaction with the dominant ethanol produces diethyl acetal, or 1,1-diethoxyethane, at the mg/1 level. Table 3 gives typical amounts of these compounds found in malt and light blended whiskey. Full malt whiskeys are produced in traditional pot stills and tend to have upper range levels of these compounds. Lighter whiskeys are blends of pot still product and whiskey produced in column stills. Therefore depending on the degree of blending commercial whiskeys can have these major congeners in a concentration range of single figure mg/1 to greater than 103 mg/1. Rapid separation and quantification of these compounds is important for reasons ranging from production consistency to market place authenticity and many different approaches have evolved, usually with the universal flame ionization detector.

Compound Malt Whiskey Blended Whiskey

Acetaldehyde 200 mg/l 76 mg/1 Ethyl Acetate 280 " 29 " Diethyl Acetal 49 " 5 " Propanol 350 " 570 " iso-Butanol 990 " 450 " Amyl Alcohols 1600 " 420 " Ethyl Caprylate 22 " 3 " Ethyl Caprate 32 " 10 " Ethyl Laurate 12 " 8 "

Table 3. Typical amounts of major congeners found in different types of whiskeys.

Packed Columns. Before the introduction of modern fused silica capillary columns chromatographers relied on packed columns with their limitations of both low plate number, and low mass sensitivity at the detector due to solute diffusion in the packing. On the other hand they have the advantage of low cost, are easy to operate, and can be produced with many specific phases for different separation problems. Open tubular capillary columns offer much higher separating power but the availability of columns with unique phases is more limited than with packed columns. Since the phase selectivity has a major effect on separation certain packed phases have retained their applicability in distilled spirits analysis.

Page 324: Instrumental

307

Duncan and Philp [3] used two gas chromatographic methods to directly determine a range of major congeners in whiskey. Using 5% polyethylene glycol 1500 on a 60-80 mesh support in a 10 ft. copper column they separated the major fusel alcohols and esters. Their second method involved using the same phase in a 27 ft. column but also incorporating in the column a small length in which dionyl sebacate was the stationary phase. This allowed the additional separation of ethyl acetate, diethyl acetal and isoamyl acetate. Brunelle [4] evaluated various stationary phases and produced a collaborative study which resulted in the adoption of an official final action of the AOAC. Kahn and Blessinger [5] reported some difficulties in this method and from their own investigations proposed two alternate methods. One of these allowed determination of ethyl acetate and fusel alcohols and was adopted as a first action alternate method. The second method allowed quantification of acetaldehyde and acetal as well as ethyl acetate and the fusel alcohols, but did not get approval until gas chromatographic instrumentation, in particular oven temperature control and programming, improved. The current AOAC official methods (16th Edition, 1995) recommend the following phases and conditions for packed column analysis of higher alcohols and ethyl acetate in distilled spirits.

23% Carbowax 1500 on Chromosorb W, 60-80 mesh, acid washed. Oven 70~ isothermal.

2% Glycerol and 2% 1,2,6-Hexanetriol on Gaschrom R, 100-120 mesh, non-acid washed. Oven 80~ isothermal.

Figure I shows a separation of whiskey congeners on this second phase, but using oven temperature programming for optimum separation.

3

4

1

Analysis Conditions: Oven: 40~ 5~ to 80~ Inj.: 100~ Det.: FID, 150~ Carriergas: 30 ml/min N 2

7

9

Compounds: 1. Acetaldehyde 2. Ethyl Acetate 3. Acetal 4. Ethanol 5. n-Propanol 5. Isobutanol 7. 3-Pentanol 8. 2-Methyl-l-Butanol 9. 3-Methyl- 1-Butanol

Figurel . Separation of whiskey congeners, packed column.

Page 325: Instrumental

308

Cabezudo and co-workers perfected the mixed phase approach to congener separation [6]. A fortran program was devised to find the best combined phases from two to four single phases for a general purpose congener separation, or best combined phases for separation of specific groups of congeners. Analyses were carried out isothermally at 50~ and allowed elution and separation of up to 20 compounds. Di Corcia and co-workers pioneered the investigation and introduction of modified graphitized carbon black for GC analysis of distilled spirits [7]. They first used Carbopack B modified with Carbowax 20 M, and trimesic acid as acidic deactivating agent, but later found that this latter treatment was not necessary if the carbon surface was initially acid washed. Different Carbowax loadings were used for different congener groups and these columns also allowed elution of free fatty acids.

Martin [8] described a single procedure, using 80-120 mesh Carbopack B as solid support and 5% by weight Carbowax 20M as liquid phase, which allowed separation of acetic acid and the isomers of amyl alcohol. These columns are presently available in Silocosteel, which is stainless steel coated with a deactivated fused silica inner layer, and the manufacturers claim improved inertness, durability and flexibility compared to traditional glass packed columns [9]. Figure 2 show separation of whiskey and rum congeners on these columns.

_IL

Analysis Conditions: Oven: 70~ 4~ to 150~ Inj.: 200~ Det.: FID, 250~ Carriergas: 20 ml/min N 2 0.5 ~1 direct injection

9

Compounds: 1. Acetaldehyde 2. Methanol 3. Ethanol 4. Ethyl Acetate 5. n-Propanol 6. Isobutanol 7. Acetic Acid 8. active Amyl Alcohol 9. Isoamyl Alcohol

Reproduced with permission from [9]

5 ._...~

Analysis Conditions: Oven: 65~ 4~ to 150~ Inj.: 200~ Det.: FID, 250~ Carriergas: 20 ml/min N 2 0.5 lal direct injection

7 9 11 2 6 8A

Compounds: .

1. Acetaldehyde 2. Methanol 3. Acetone 4. Ethyl Formate 5. Ethanol 6. Ethyl Acetate 7. n-Propanol 8. sec-Butanol 9. Isobutanol 10. active Amyl Alcohol 11. Isoamyl Alcohol 12. n-Amyl Alcohol

Reproduced with permission from [9]

Figure 2. Separation of whiskey (top) and rum congeners on 2m x 2mm 5% Carbowax 20M 80/120 CarboBlack B column.

Page 326: Instrumental

309

Finally a phase with a specific selectivity has recently been described [ 10] for monitoring compounds such as 2-propanol and acetoin in spirits and distilled wines. F igures 3 and 4 compare separation of a standard solution of congeners on this column compared to the standard Carbowax 1500 phase. 2-Propanol and acetoin which can be markers for adulteration or oxidation changes coelute with the dominant ethanol on the standard phase.

EtOH 5

3

,7

Analysis Conditions: Oven: 55~ 60~ to 145~ Inj.: 200~ Det.: FID, 200~ Carriergas: 15 ml/min N 2 1 pl direct injection

12

Comoounds; 1. Acetaldehyde 2. Methanol 3. 2-Propanol 4. n-Propanol 5. Ethyl Acetate 6. 2-Butanol 7. Isobutanol 8. n-Butanol 9. Acetoin 10. 2-Methyl- 1-Butanol 11. 3-Methyl- 1-Butanol 12. 4-Methyl-2-Pentanol (int. Std.) 13. Ethyl Butyrate

Reprinted from the Journal of Chromatographic Science with permission of Preston Publications, a division of Preston Industries F igu re 3. Chromatogram of a standard solution using a 2m x 2mm MFE-Vinicol column.

EtOH+3+9

5 2 Analysis .Conditions: Compounds: Oven: 85~ isothermal 1. Acetaldehyde lnj." 200~ Det.: FID, 200~ 2. Methanol Carriergas: 15 ml/min N 2 3. 2-Propanol 1 lal direct injection 4. n-Propanol

5. Ethyl Acetate 6. 2-Butanol 7. Isobutanol 8. n-Butanol 9. Acetoin 10. 2-Methyl- l-Butanol

13 11. 3-Methyl- 1-Butanol 12. 4-Methyl-2-Pentanol (int. Std.) 13. Ethyl Butyrate 10+11

Reprinted from the Journal of Chromatographic Science with permission of Preston Publications, a division of Preston Industries

F igu re 4. Chromatogram of a standard solution using a 4m x 2mm Carbowax 1500 column.

Page 327: Instrumental

310

Capillary Columns. The open tubular design of capillary columns, where a phase without support packing is deposited as a thin film on the inner wall of a low internal diameter column offers significant performance advantages, but also places greater demands on the entire chromatographic operation. The practical differences between packed and open tubular column separation results from reduced intra brand broadening for individual solute molecules in the capillary and the much longer column lengths allowed by the open tubular design. These factors have been summarised by Jennings [ 11 ] as follows :

A packed column will offer a range of flow paths to solute molecules giving a spread of residence times in the mobile phase. The open tubular design offers a single flow path with more uniform movement in and out of the mobile phase.

Solute molecules also experience a similar wider residence time spread in the stationary phase due to its much higher concentration in a packed column and its non-uniform film thickness.

Packing materials are inefficient at heat transfer and so a range of temperatures will exist across any transverse section of the packed column. Solute volatiles are affected and this again leads to dispersion of individual molecules of the same solute.

These factors therefore express themselves as compounds that elute with wide peak widths after short residence times in packed columns and mass sensitivity at the detector will be low for later eluting compounds. Co-elution and overlapping cannot be easily avoided. For this reason specific phase selection is very important for packed columns as the separation factor has to be optimised to compensate for these inherent disadvantages.

The open tubular design brings its own difficulties, principally in terms of the need for increased GC hardware sophistication, and especially the problem of transferring the sample compounds in a narrow band to the small diameter capillary column. The earliest columns were glass and required special deactivation procedures with delicate handling and manipulation. The trend at that stage was also to modify packed column instruments and the technique was largely confined to specialist laboratories. The introduction of robust, flexible, fused silica columns and chromatographs with dedicated capillary pneumatics, injectors and detectors, and especially more precise oven temperature control (Hewlett-Packard 5880A) finally made the technology much more accessible.

Grob et. al. were among the first to investigate direct analysis of distilled spirit congeners on glass capillary columns [ 12]. They used a column coated with Carbowax 400 and injected with splitting and an oven starting temperature of 25~ This phase was not bonded to the column wall in the sense that it was not non-extractable and so the first 60 cm of the column was left without phase to avoid its removal and subsequent redeposition problems, which condensation at the low initial temperature could cause. De Nijs and de Zeeuw reported a chemically bonded Carbowax on fused silica which they termed CP Wax 57 CB [ 13]. This column was resistant to washing with polar solvents such as methanol and even water, and had an upper temperature limit of 220~ MacNamara used this column with split injection to profile the major congeners in distilled spirits [ 14] and Figures 5 and 6 shows typical separations for a standard mix of congeners and a whiskey.

Page 328: Instrumental

311

" 12113

l'l A:a~s40Cc;dmiti2~s; ~ C/min t~ 200~ I I lnj.: 200~ Det.: FID, 200~ [ I Carriergas: 40cm/s H 2

I! i ~ 4 tel I 18 J

~ ) _ 9 23 24

F i g u r e 5. Split capillary separation of a standard congener mixture in 40% v/v ethanol on a 50m x 0.25ram x 0.25pm CP-Wax 57 CB column.

7 8 12 j13 Compounds: [ 1. Acetaldehyde 14. Ethyl Caproate I 2. Methyl Acetate 15. Ethyl Lactate I 3. Ethyl Acetate 16. Ethyl Caprylate I 4. Diethyl Acetal 17. Furfural

"~ 11 J 5. Methanol 18. Ethyl Caprate [ 6. Butanol-2 19. Phenyl Ethyl Acetate [ 7. Propanol 20. Ethyl Laurate

" t 8. Isobutanoi 21. 2-Phenyl Alcohol II 9. Isoamyl Acetate 22. Lauryl Alcohol 11 10. Butanol-I 23. Ethyl Myristate l[ 11. 4-Methyl-2-Pentanol (int. Std.) 24. Myristyl Alcohol 1[ 12. 2-Methyl- 1-Butanol 25. Ethyl Palmitate I 13. 3-Methyl- 1-Butanol

,L li 161 20 21

Figure 6. Split capillary separation of a commercial whiskey on a 50m x 0.25mm x 0.25pm CP-Wax 57 CB column.

Page 329: Instrumental

312

CP Wax 57 is a unique phase with a unique selectivity, and major advantages are separation of the following pairs:

ethyl acetate -diethyl acetal

isobutanol- isoamyl acetate

isomers of amyl alcohol

Diethyl acetal and isoamyl acetate have quite low sensory thresholds, but in addition exhibit azeotropic behavior with ethanol and water which effect their behavior during distillation. Table 4 gives composition and boiling point data for the ternary azeotropes of these two compounds with ethanol and water, and shows that the net boiling points of the compounds have been reduced to below the boiling point of the common ethanol-water azeotrope.

A-Component, B-Component, C-Component, ._ Aze0tropic Data B.P. (~ B.P. (~ B.P. (~ B.P. Wt. Wt' Wt .

(~ (%A) (%B) (%C)

Water, Ethanol, DiethylAcetal, 11.4 27.6 61.0 100 78.3 103.6 77.8

Water, Ethanol, Isoamyl Acetate, not stated 100 78.3 142.0 69.0

Table 4. Ternary azeotropes of ethanol~water with diethyl acetal and isoamyl acetate.

Distillation fluctuations or non-equilibrium conditions can therefore affect the levels of these compounds in a spirit, and even though their absolute concentrations will be quite low, perceived aroma can be influenced through their high odour intensities. The information in Figure 5 and 6 traces is also a balance which is determined by the injection split ratio. The split ratio is used to meter the proportion of the injection volume delivered to the column and is a trade-off between resolution before and just after the ethanol peak, and useful sensitivity for later eluting compounds. If the split ratio is too low resolution and peak shape for pre-ethanols suffers due to a reverse solvent effect [ 12] if it is too high detection of the late eluters becomes more difficult. The late eluting compounds in these traces, where the split injection amounts are much less than could have been delivered to a packed column, highlight previous comments on increased detector mass sensitivity.

This column is also very stable and our experience is to obtain 2 years daily use without any deterioration in performance. A baseline separation for the amyl isomers is not achieved but this is not necessary for accurate ratioing due to the 70/30 proportions usually found in distilled spirits. A more polar phase such as Carbowax 400 with much lower viscosity will baseline sepa- rate 2- and 3-methyl- 1-butanol (Figure 7) but is a non-bonded phase and has an upper temperature limit of only 100~ A disadvantage is that CP Wax 57 does not elute symmetrically free fatty

Page 330: Instrumental

313

acids and an alternative approach is necessary for these compounds. Masuda et. al. [ 15] injected whiskey directly with splitting to a relatively apolar 5% phenylmethyl silicone capillary and achieved separation of a combination of alcohols and esters together with acetic, octanoic, decanoic and dodecanoic acids. Analysis Conditions:

Oven: 50~ isothermal Inj.: 150~ Det.: FID, 200~ Carriergas: 90kPa H 2 0.1 lal split injection (100 ml/min)

5 4

3

Reproduced with

Compounds: 1. Ethyl Acetate 2. Methanol 3. Ethanol 4. Isoamyl Acetate 5. 2-Methyl Propanol 6. 1-Butanol 7. 2-Methyl- 1-Butanol

6 8. 3-Methyl- 1-Butanol

)ermisslon from Chrompack B.V., Middleburg, The Netherlands

Figure 7. Separation o f a testmix on a 50m x 0.32mm x 0.21um Carbowax 400 column.

Direct splitless injection of distilled spirits is also possible and can give additional and complimentary data to that produced by split injection of the same sample [ 16]. F igure 8 shows a direct splitless injection of a whiskey on an FFAP phase, which is a standard Carbowax polymer modified with nitroteraphthalic acid. The splitless injection transfers much more matrix and congeners to the column and gives increased peak areas for late eluting and minor congeners, together with symmetrical peaks for free fatty acids. The resolution of peaks around the solvent has been

" _ 6 ~ Compounds: 1. Ethyl Caprylate 2. Acetic Acid 3. Furfural 4. Ethyl Caprate 5. Ethyl Laurate 6. 2-Phenyl-Alcohol 7. Ethyl Myristate 8. Caprylic Acid

' 9. Ethyl Palmitate 10. Capric Acids

" Analysis.Conditions_: Oven: 60~ 3~ to 220~ lnj." IYFV, 40~ 12~ to 220~ Det." FID, 200~ Carriergas." 40cm/s H 2

Figure 8. Splitless injection o f a whiskey on a 60m x 0.25ram x 0.25pro FFAP column.

Page 331: Instrumental

314

destroyed but this information is available from a corresponding split injection of the same sample. Therefore each injection mode gives unique and complimentary information which builds a comprehensive profile of the most abundant congeners. This approach was applied to quantify thirty three compounds in 14 samples of each of two different malt whiskeys [ 17]. Using linear discriminant analysis techniques a very good differentiation of the two types could be obtained (Figure 9) and it is also clear that the intra variation in one of the whiskeys is more pronounced. Further statistical testing showed that five compounds alone could account for 98.5% of the variation. Four of these compounds were quantified from the splitless part of the analyses.

1.0-

0.5

-0.0-

-0.5-

-1.0- -1'.0

Malt A

o , ~ o o

o o r < , o

Malt B

�9 - 0 ' . 0 �9 1 1 0

Figure 9. Differentiation of whiskeys using direct injection congener data.

Figure 10 shows Chernoff faces for the two whiskey sets constructed on these five compounds.

Figure I0. Chernoff faces for malt A (top) and malt B, constructed on different levels of five compounds.

Page 332: Instrumental

315

One problem which detracts from the usefulness of direct splitless injection is the variability of FFAP columns from different commercial sources. This is related to different procedures for modifying the Carbowax phase with nitroteraphthalic acid to induce acidity. The treatment probably produces an ester linkage which can be more easily hydrolysed by certain solvents and conditions. A result of this is that the acidity can be removed with repeated injections and the phase will slowly evolve into standard Carbowax, with increasingly deteriorating acid peak shape. Figure 11 show this phenomenon in its early stages. After about 50 injections the column is loosing acidity and is eluting acids faster than a new column. The pairs furfural and acetic acid, and C~6 ~- ester and C~0-acid, have actually inverted, and the C~0-ester and Ca-acid pair are about to.

Analysis Conditions; Oven: 60~ 3~ to 220~ Inj. PTV, 40~ 12~ to 220~ Det. FID, 200~ Carriergas: 40cm/s H 2 I lal splitless injection (2min)

Compounds: 1. Furfural 2. Acetic Acid 3. C~0-Ester 4. Ca-Acid 5. Ct6 t-Ester 6. Clo-Acid

Analysis Conditions: Oven: 60~ 3~ to 220~ lnj.: PTV, 40~ 12~ to 220~ Det.: FID, 200~ Carriergas: 40cm/s H 2 1 pi splitless injection (2min)

Compounds: 1. Furfural 2. Acetic Acid 3. CIo-Ester 4. Ca-Acid 5. Cl6:t-Ester 6. CI0-Acid

Figure 11. Splitless injection of a whiskey on a new (top) and a deteriorating 60m x 0.25mm x

0.251am FFAP column.

Page 333: Instrumental

316

After further use acid peak shape begins to deteriorate and the column must be changed. This behavior and its extent differs with similar columns from different manufacturers. With columns that allow a reasonable number of injections, direct splitless analysis gives rapid useful information that must be balanced against costs of higher column usage.

Splitless injection is a complicated process involving slow transfer of compounds of interest to the capillary column for refocusing and separation. In conventional hot splitless injections a pressure wave is created by the explosive vaporisation of the sample, giving a non-homogenous vapour cloud which is a recipe for discrimination. The same effect distributes the sample and any involatiles it may contain to every comer of the injection liner. Compounds of interest can be lost through the septum purge and involatiles have a greater chance of reaching the column entrance. Cold programmable injection (PTV), where the sample is deposited cold in a glass liner which is then linearly programmed to the desired final temperature, is aesthetically and technically superior to conventional flash vaporisation. Both discrimination and decomposition of labile substances have been shown by various authors to be dramatically reduced [ 18-20].

When a sample is deposited cold in a programmable injector its compound content can be uniformly removed by programmed heating and any involatiles tend to remain relatively undispersed in a section of the liner. One such injector (Gerstel CIS-3) also has a septumless head which both simultaneously avoids septum particle problems, and the need for a septum purge flow which gives discrimination and general loss of compounds. Table 5 gives reproducibility of absolute peak areas for 6 replicate autosampler runs of ppm solutions of C13-C20 hydrocarbons in hexane using cold split and splitless injection. The numbers given are expressed as % relative standard deviation from the 6 runs.

Mode Cl3 El 4 Ci5 C16 Ci7 C18 C19 C20

split 1.12 0.98 0.90 0.58 0.83 0.82 0.72 0.65

splitless 0.86 1.06 1.04 1.52 0.68 0.64 1.02 0.73

Table 5. Reproducibility of absolute peak areas for cold split and splitless PTV injection.

There is no essential difference in the reproducibility of the split mode compared to the splitless mode and both offer a reliable and reproducible method for capillary sample introduction.

One important variable in splitless injection is the splitless or transfer time and cold injectors have a distinct advantage here. They have liners with smaller intemal diameters than conventional injectors to provide a low thermal mass and allow rapid heating. This in turn allows a higher carrier gas velocity in the smaller i.d. liner and means transfer of the compounds to the column is faster and occurs at lower temperature. This can be even further enhanced by using pressure programming (a higher inlet pressure) during the splitless transfer. Figure 12 shows the effect of liner diameter on the splitless transfer of the C30 hydrocarbon in hexane. 75% is transferred to the column at a temperature of 210~ for the 1.2 mm i.d. liner, and 290~ is required for the 3.4 mm i.d. liner [21 ].

Page 334: Instrumental

317

o

o g~

100-

75-

50-

25-

0 0

0 ~

!.2 mm

�9 + ~ , ,

+ _ _ ,300

-250 o

-2oo

-150

100 E

-50

1'0 2() ' 3() 4'0 5i) 60 Splitless time (sec)

Reproduced with permission from [211

Figure 12. Effect of liner diameter on PTV splitless transfer Dashed line: actual temperature in the liner

Cold programmable injection is the method of choice as a universal capillary injection technique and avoids the different disadvantages of hot split/splitless and cold on-column approaches. It can also be used for large volume injection applications and adapted to headspace and thermal desorption devices, and these areas will be investigated later.

An additional major advantage of capillary columns is that their small volumetric flow requirements allow the use of low-cost benchtop mass spectrometers as GC detector. The column can be directly interfaced to the ion source and the latest PC-based control and data reduction technology make this technique very accessible. When such a GC-MS is used in selected ion monitoring mode (SIM), the range of compounds that can be detected and quantified by direct splitless injection of spirits is profitably increased. In the SIM mode only characteristic ions from selected compounds are monitored continuously, rather than scanning all ions over a mass range. In the former case the time spent detecting the ion current at a particular mass is a much higher percentage of the total cycle time than in scanning mode. This is manifested as an apparent increased instrument sensitivity but is in fact due to a much higher signal-to-noise ratio.

The application of this approach means that higher esters can be directly quantified in light whiskeys where their level is at low or sub-ppm level due to a high blend ratio. The same approach can be used for similar level trace phenolics that contribute to peatiness in full malt whiskeys. In practice operating procedures are established which involve programming the instrument acquisition parameters to monitor specific ions from the known compounds in specific retention time windows. Ions to be monitored must be carefully chosen as there is always the danger of interference from the same ions from other compounds. To make the best use of this approach a dedicated software package [22] is recommended for target compound analysis.

Page 335: Instrumental

318

In general the three principles inherent to target compound analysis are:

- Presence and integration of all the target ion masses.

- All ions must co-elute within a retention time window.

- Target ion ratios must fall within a calibrated range.

A compound is determined to be present if the characteristic ions (a reference ion and up to 2 qualifier ions) are detected co-elulting in a specified retention time window and they meet the ion ratio tests (Figure 13). The specified retention time windows for locating the characteristic ions can be defined in terms of absolute or relative retention time, or retention time relative to an internal standard. The ion co-elution test is then performed and this usually employs a small absolute time window to test for co-elution.

~ tep 3"

~ ~ S t e p 2:

L Step 1"

Figure 13. Target concepts.

Qualifier ions co-elute with reference ion

Reference ion in retention time window

Peaks integrated in extracted ion window

Reproduced with permission from [22]

This window can be as small as one scan (or 0.025 mins) and is quite a strenuous test. When this test fails, even after optimum adjustment of instrument parameters, the entire analytical methodology needs to be re-evaluated. The final test is the ion ratio test, and the area ratio of the qualifier ions to the reference ion must fall within a target ion ratio limit, which is defined as acceptable variance of the ion ratio from the calibrated ratio. The calibrated/expected ion ratio for each qualifier can be automatically determined using the ion ratio from a calibration run.

When compound parameters and calibration data are correctly programmed, samples can be automatically run and processed with comprehensive report generation. Figure 14 shows a selected ion monitoring TIC for 7 compounds in a very light blend after 1 lal direct splitless injection, with

Page 336: Instrumental

319

decanol-3 as internal standard. Table 6 gives the corresponding report with amounts based on four levels of calibration. The reference and qualifier ions for each compound are also shown together with ion retention time and confirmatory ion ratios. Direct injection and the high SIM S/N ensures very good accuracy and precision.

60(0X)0-

400000

20(K)(O 1

!

20

Analysis Conditions: Oven: 60~ 3~ to 220~ lnj.: PTV, 40~ 12~ to 220~ MSD Carriergas: 40cm/s H 2 1 lal splitless injection (2min)

2

Compound.s: 1. Ethyl Caprylate 2. Decanol-3 (ISTD) 3. Ethyl Caprate 4. Phenyl Ethyl Acetate 5. Ethyl Laurate 6. 2-Phenyl Alcohol 7. Ethyl Myristate 8. Ethyl Palmitate

5

3'5 2'5 3'0 40 4'5

8

A____ go

Figure 14. Selected ion monitoring chromatogram for 7 compounds, very light blend.

Compound RT Mass Area Amt Ion Target (mg/l) Range

Ion Ratio found

Ethyl Caprylate 19.64 88 5273036 1.878 19.64 101 1785649 27.15 - 40.73 19.64 127 1173132 17.58 - 26.38

Decanol-3 (ISTD) 26.81 59 11103872 3.200 26.81 69 9561073 68.81 - 103.21 26.82 111 1784033 12.69 - 19.03

EthylCaprate 28.29 88 13988259 5.228 28.29 101 5563892 31.91 - 47.87 28.29 115 1022386 5.72 - 8.58

Phenyl Ethyl 35.77 104 1306376 0.316 Acetate 35.76 91 286197 17.79 - 26.69

35.77 65 173271 10.26- 15.38 Ethyl Laurate 36.55 88 12581317 3.709

36.55 101 5884328 37.20- 55.80 36.55 157 1337508 8.30- 12.46

2-Phenyl Alcohol 39.52 91 7174672 1.628 39.52 92 3732274 41.97 - 62.95 39.52 122 1506499 16.79- 25.19

Ethyl Myristate 43.91 88 1252651 0.583 43.91 101 641310 41.54 - 62.32 43.91 157 145820 9.22 - 13.82

Ethyl Palmitate 50.62 88 2542767 1.605 50.62 101 1369236 43.51 - 65.27 50.62 157 270671 8.31 - 12.47

100.00 33.86 22.24

100.00 86.10 16.06

100.00 39.77

7.30 100.00 21.90 13.26

100.00 46.77 10.63

100.00 52.02 20.99

100.00 51.19 11.64

100.00 53.84 10.64

Table 6. Corresponding report to Figure 14.

Page 337: Instrumental

320

Specialised Direct Injection Techniques. Hagman and Roeraade described an approach using precolumn backflush to selectively profile the pre-ethanols in alcoholic beverages [23]. In this configuration (Figure 15) a short packed precolumn was coupled to a capillary column via an effluent splitter. After injection the volatile pre-ethanol congeners passed to the main capillary column and the remaining less volatile compounds were backflushed from the pre-column using a 10 port rotary valve. By keeping part of the pre-column in the hot injector, and the rest in the GC oven, the authors achieved an acceptable balance between rapid sample evaporation and preseparation in the precolumn. The preseparation could also be influenced by the split ratio, since this also influences the flow through the precolumn. Shiomi [24] used a two-oven multi-

Carrier Gas In Heated Inlet

V i l / a c k e d _ Precolumn

V2 Splitter

GC Oven

Column

Reproduced with permission from [23]

Figure 15. Configuration for precolumn-backflush.

dimensional system and two wide bore columns of opposing polarity to achieve baseline separation of diethyl acetal from the pre-ethanol group of compounds. The acetal co-eluted with ethyl acetate on a wide bore Carbowax precolumn, and this segment was heartcut to an apolar widebore column for the increased resolution. By using a single capillary column, with lower internal diameter to give more plates per meter, acetal and ethyl acetate can usually be adequately separated.

MATRIX REMOVAL The range and number of flavour contributing trace compounds in distilled spirits that are not readily amenable to direct injection is very substantial. Sample preparation involving matrix rem- oval is a prerequisite for further analysis, and strategies must be carefully chosen to minimise cost and effort. This is a vast area and this section only attempts to describe general approaches with an emphasis on strategies that can be further complimented by injection or chromatographic techniques and/or provide additional sensory information.

Since many of the contributing trace congeners are already known from previous research efforts, solvent extraction gives sufficient enrichment to allow detection. An apparatus for

Page 338: Instrumental

321

continuous extraction (Figure 16) has been described by Rapp and Mandery [25].

Figure 16. Apparatus for continuous extraction with Freon.

Spirits are reduced to 15% v/v and a total volume of 250 mls at this strength can be extracted by 50 ml of Freon 11 (fluorotrichloromethane)containing 10% dichloromethane. This mixture has an azeotropic boiling point of 26~ and so the extraction proceeds virtually at room temperature. In experiments with model solutions these authors found that after 20 hours a very good enrichment of most trace congeners can be obtained. The solvent can also be removed and recovered at low temperatures and the residual solvent can be substituted for ethanol to give extracts which retain the flavour complexity of the original distillate. The apparatus requirements are also quite simple and 6-12 continuous extractions can be performed overnight.

A simpler but less intensive approach using a higher boiling Freon has also been described [26, 27]. 10 mls of spirit at 20% can be batch extracted with 100 I.tl of Kaltron (1,1,2-trichloro- trifluoroethane) by simple shaking, and the Kaltron extract can then be removed directly for GC injection. Liddle outlined a similar approach using iso-octane as solvent and extracting by vortex mixing [28]. These approaches are simple and cost effective but can never give the degree of enrichment achieved with an overnight continuous extraction of larger quantities. But if the simple batch extraction is also regarded as a procedure for transferring compounds into a diffe- rent solvent, then the technique of large volume injection can be used to compensate for the lower extraction efficiency and provide greater analytical automation. This idea will be investigated in a later section.

Page 339: Instrumental

322

For more detailed information physical techniques with and without solvent extraction can be used to enrich and preparatively segment distilled spirits. The most comprehensive approach in this area was described by Ter Heide and colleagues [29, 30] who perfected a separation scheme (Figurel7) for distilled beverages that allows maximum sensory and analytical information. 500 liters of the distilled beverage under investigation is batch extracted with a specific solvent mix to give a flavour complex. This was then subjected to many sub-separations, including distillation and preparative chromatography, and at each stage the isolated fractions and components were examined by an expert sensory panel. Not only were many new compounds identified by this work, but also their relative contribution to the overall beverage flavour could be investigated.

Ethanol / Water -! . . . . l

[ Distilled Beverage i I

Solvent Extraction

Na-Salts of Acidic Compounds ] I

Flavour Complex ]

Regeneration

pH=l pH=9.5 I I

[ Acids ] i Phenols ]

I NaOH

I

Fusel Components[

NonVolatiles ]

! [ Neutral Flavour Complex ]

I Distillation

[ Fusel-free Flavour Complex I

Short Path Distillation

[ Vo,atileFlavourCompoun s 1 I

Several Chromatographic Methods

I I I I Many Fractions

! I

Reproduced with permission from [1]

Figure 17. Comprehensive separation scheme for distilled beverages.

Page 340: Instrumental

323

When the resources of an intemational flavour company are not available, then less comprehensive approaches have to be developed to give similar results. Figurel8 shows an automated fractional vacuum distillation apparatus which can be used to fractionate up to four liters of a distilled spirit. Distilling at 80 mbar and recirculation of the sample through a thin-film evaporator ensures low temperature fractionation and minimum contact time of the solutes with heated surfaces. The separation results from the combined effects of solute volatility and azeotropic behavior and

|

Reflux Divider

Separation Column

Motor

J L i i 'Pre-Hc

Thin Film Evaporator

Circulation Pu i

. . . . . . . . . ..I

Head Condenser

Distillate R eceivers

~___ _ ~ . . . o - -

Cold Traps

Vacuum Pump ~. ,~,

Reproduced with permission from Normschliff, Wertheim, Germany

Figure 18. Apparatus for vacuum fraction distillation.

Page 341: Instrumental

324

gives concentrated fractions of volatile and fusel compounds. The liquid nitrogen traps ensure complete recovery and since there is no solvent involvement, the concentrated fractions can be readily investigated for aroma and taste. Since the fractionation is also strongly influenced by volatility, the fractions themselves are suitable for matching with different injection techniques and different capillary columns. The first fraction will contain only the volatile top notes of the distillate and is recovered exclusively from the cold traps. This sample is best analysed on a highly retentive column and Figures 19 and 20 show traces on such a column compared to a regular capillary column.

10000

5000

0 1 ' 0

Analysis Co..n.dition.s" Oven: 40~ 5~ to 240~ Inj.." PTV, 40~ 12~ to 220~ �9 FID, 250~ Carriergas: 24 psi He 1 lal split injection (1/30)

3'0 . . . . 4'0

Figure 19. Volatile top notes of the distillate, separated on a standard 60m x 0.25mm x 0.251am Carbowax 20M column.

10000-

5000

0 TI~ 0

F - - 7

I i I

I

J i

I I

Analysis Conditions: Oven: 40~ 2~ to 80~ 5~ to 220~ lnj.: lrl~, 40~ 12~ to 220~ Det.: FID, 250~ Carriergas: 7 psi He 1 Ial split injection (1/30)

fo 2o 3o 40

Figure 20. Volatile top notes of the distillate, separated on a highly retentive 30m x 0.32mm x

5.01am 5%Phenyl-Methylsilicone column.

Page 342: Instrumental

325

Taniguchi recently described an approach using centrifugal partition chromatography to separate aroma substances in whiskey new distillates [31]. This is a liquid liquid partition between two immisable solvents and the centrifugal field retains the stationary phase solvent more firmly in the separation columns. Using the less polar solvent as mobile phase allowed faster elution of less polar esters and acetates (Figure21) and in this way they could preparatively separate slightly more polar sulfur compounds of interest.

i (2) , ~ . , - - ~ . , .

0 ' 0

, �9 . . . . 1 . 7

. : (4)

i o

| i

�9 i

:

' F r . 3 6 ' F r . 3 7

t . . . . . FrGr I

!

!

I

0

.3. o . . J . .

o

o.

s

Fr. 38

I . . !

E I O

o ~ ~ oEt OEt

. . . . .

t

Fr. 40 ' - FrGr2 -

Ethyl e s t e ,~s �9 S _ [

i (1) ! Acetates ] t ' " I ' ~ x 4J

�9 , ' O ~

: : (3) i

,' ~ ~ ~ Fatty Acids !:

i i t

,, ,0 :

; ' o>__) i i : i i . E, A c c t a l s i i t,o | i i

J i 0

t # �9 : :

: Fr. 44 ' Ft. 47 ' t FrGr 4-----l--~FrGr 5 I Reproduced with permission from [31]

F i g u r e 21. Compounds eluted in earlier fractions by centrifugal partition chromatography (FrGr: fraction group).

Their initial starting material was a concentrated solvent extract of a whiskey and after separation and solvent substitution for ethanol, the fractions could be investigated sensorially. Compounds more polar than ethyl lactate remained in the stationary phase and were recovered from the same.

LARGE VOLUME INJECTION Figure 22 shows specific sulfur traces, with solvent venting, for increasing injection volume of a simple Kaltron extract of a whiskey, compared to a normal non-solvent splitting injection. The traces serve as an introduction to this rapidly developing, technologically important area of capillary gas chromatography. Except for a loss of very early eluting compounds during solvent splitting, the recovery of the majority of the sulfur species correlates with the injection volume. The two most important advantages of this technique are reduced sample preparation time and greater levels of sensitivity. Substantial investigation of the variables and parameters for successful implementation have been described by various authors and commercial chromatographic units are available for complete automation of procedures.

Page 343: Instrumental

326

1.0e+06 ::

8oooooi

600000

400000

2ooooo 0

1.0e+06-

80(0)00

600000

400000

200(0s

Analysis Conditions: Oven: 40~ 5~ to 250~ lnj.: PTV, 60~ 10~ to 250~ SCD Carriergas: 14 kPa He 5 lal splitless injection (lmin)

l O 20 30 40

Analysis Conditions: Oven: 40~ 5~ to 250~ Inj.: PTV,-20~ 10~ to 250~ SCD Carriergas: 14 kPa He 40 IA injection, solvent venting with 201.d/min injection speed, then splitless (lmin)

0 10 20 30 40

1.0e+06:

80(0)00

600000

400000 �84

20(0)0

Analysis Conditions: Oven. 40~ 5~ to 250~ Inj." PTV,-20~ 10~ to 250~ SCD Carriergas." 14 kPa He 100 ~1 injection, solvent venting with 201al/min injection speed, then splitless (lmin)

0 10 20 30 40

Figure 22. Specific sulfur traces of a Kaltron extract, 5, 40 and 100 pl injected (from top) on 15m x 0.53mm x 1.Opm Supelcowax 10.

Page 344: Instrumental

327

Large volume injection into capillary columns can be classified into two categories, depending on whether the solvent is separated from the solutes in the injector or in the chromatographic system [32]. In the latter case the large volume is passed directly to the column and can give rise to the well known problems of solvent flooding, phase damage and solute peak deformations [33]. Use of a retention gap, i.e short length of deactivated uncoated capillary tubing, between the injector and the main column, can refocus broadened deformed peaks [34]. For general industrial practitioneers this approach can be impractical as additional leak-tight capillary to capillary couplings are required, and the retention gaps will need frequent changing if they become dirty or deactivated. When the solvent is removed using the temperature programmable features of a cold injector, three distinct approaches can be defined:

- Solvent venting or splitting. This was the approach used by Vogt and co-workers who were the initial pioneers in this field [35,36]. The sample is introduced slowly with the split vent open, and the injector at a suitable temperature below the solvent boiling point. After a certain period the split valve is closed and the solute contents of the large volume are transferred in the splitless mode to the column. The solutes are enriched out of the gas phase.

- PTV vapour overflow. This is a technique which was developed by Grob [37] and involves injecting the sample in the splitless mode, but at a relatively high injector temperature and with a substantial septum purge flow. The solvent flash evaporates and escapes with the septum purge flow, but low volatility solutes are retained in the liner due to the solvent evaporative cooling effect.

- Solid phase extraction (SPE) in the liner. In this case the sample as a liquid is passed through an adsorbent-packed liner by a high flow of carrier gas. The solutes are retained in the packing material and after drying the liner is heated to transfer the compounds to the column [21,38]. The solutes are enriched out of the liquid phase. This technique can only be applied to aqueous samples and a special valve configuration is necessary to prevent water from reaching the analytical column.

Both the PTV vapour overflow technique and the SPE/FFV approach have practical disadvantages; the former is limited to low volatility solutes and the later to aqueous samples. For these reasons the solvent venting technique represents the best practical approach and it is in this area that most development work has been done. Some early results in this area were from the publications of Herraiz [39] and Villen [40]. Herraiz and co-workers investigated the efficiencies of several packing materials when they act as a substitute for low PTV initial temperatures. Test mixes of various compounds were prepared in Freon 11 and 2 lal injections were introduced onto the different packed liners with solvent venting at an initial temperature of 30~ Tenax gave the best overall performance in terms of recovery of volatile and semi-volatile compounds. Chromosorb 101 gave similar results but its maximum allowable upper temperature of 220~ was disadvantageous for desorption of less volatile compounds. Villen and co-workers compared the normal off-line external concentration of an extract with internal concentration on the adsorbent bed of a PTV liner in the solvent split mode. Again using Tenax as adsorbent the data showed that the internal PTV concentration gave more precise and accurate results. Grob has pointed out that

Page 345: Instrumental

328

the usual off-line concentration can involve significant loss of volatile components due to co- evaporation with the solvent [41]. The volumes injected in this study ranged from 2.5 to 25 lal.

A much more fundamental study of solvent elimination was carried out by Staniewski and Rijks in 1992 [42]. They thoroughly investigated the optimization of a PTV injector for large volume injection with solvent splitting, as a function of liner temperature and design, solvent type, speed of introduction, and purge gas flow and purge time during venting. The sequence of events occurring during the entire process is shown in Figure 23. The solvent elimination rate determines the speed of sample introduction and these processes must be matched in order to achieve a steady state in the liner, so that the mass flow of liquid solvent entering equals the mass flow of solvent vapour being eliminated.

Cold Sample Injection & Transfer

Solvent " E l i m i n a t i o n ,

I !

J �9 j .: .w

J J

On io.

Separation

. . . . . . . ~ Liner �9 - ' ~ , , .

iColu . n a n ~ iTemperature

!On [ Purge Status _

�9 Inlet Pressure Needle

J Injection ~ . . ....

Time

Reproduced with permission from [42]

Figure 23. Sequence of events during sample introduction, solvent elimination and sample transfer.

Pentane Dichloromethane

Acetone Chloroform

Methanol Tetrahydro Furane Diisopropyi Ether

Hexane Ethyl Acetate Cyclohexane Acetonitrile

Water ~ 1,4-Dioxane

10.4 |0.7 ~ 3 . 3 111.5 ~ 4 . 8 111.5 |1.1 111.2 ~2.6 112.2 ~ 4 . 9

~ 7 . 1

59.6

0 1'0 2b Volume (ml)

Reproduced with permission from [42]

Figure 24. Saturated vapour volumes of 11~l of different solvents at 20~

Figure 24 shows the saturated vapour volumes for unit volume of different solvents at 20~ and these values are the minimum volume of gas required to remove the solvent as vapour from the liner. Therefore more polar solvents will need a relatively longer time to eliminate. The maximum injection rate which is equal to the solvent elimination rate, can be increased by decreasing the pressure in the liner and increasing the total gas flow rate in the liner. Newer instrumentation with electronic pressure control allow the necessary automation of these parameters. A further advantage is that low programmed pressure during solvent elimination results in much less solvent transfer to the column, even for very large volumes. Based on the above considerations a model was proposed to calculate the best sample introduction rates, liner temperatures and purge flows for optimum recover 3' of test compounds in various solvents. They injected 150 lal of such a test mix in hexane to a liner packed with glass wool and achieved 90% recovery of components with volatilities lower or similar to a heptadecane.

Page 346: Instrumental

329

For the traces in Figure 22 from the Kaltron whiskey extract the following calculations were applied based on the recommendations of Staniewksi and Rijks.

M �9 Pv * s Po d * R * T - - * - I Pi

I = max. solvent venting speed (lal/min) M = molecular weight of solvent (g/tool) Pv = vapor pressure of solvent at inlet temperature (bar) s = split flow (ml/min) d = density of solvent (g/mol) R = gas constant (0.08312 l*bar/K*mol) T = temperature of PTV inlet (K) p,, = absolute pressure at split outlet (bar) p, = absolute inlet pressure (bar)

For Kaltron (1,1,2-trichloro-2,2,1-trifluoro ethane), with an inlet temperature o f - 10~ a split flow of 100 ml/min and an inlet pressure of 0 ("stop flow") the following maximum sample introduction speed can be reached'

187 �9 0.0868 �9 100 1 �9 = 47.0 pl/min Kaltron

1 . 5 8 , 0 . 0 8 3 1 2 �9 263 1

It could be naturally assumed that the boiling point of a solvent is the dominant contributory factor when calculating its elimination rate as a vapour. However the following comparison for water (bp. 100~ and isooctane (bp. 99~ show the necessity of utilizing all the equation parameters.

114 �9 0.2803 �9 100 1 , 0 . 6 9 , 0 . 0 8 3 1 2 �9 333 1

= 167 pl/min isooctane

18 �9 0.1956 �9 100 1 �9 = 12.7 pl/min water

1 * 0.08312 �9 333 1

For practically similar boiling points there is more than an order of magnitude difference in the solvent venting rate at the same temperature.

MOiler and co-workers determined pollutants in aqueous samples by a similar approach but with a liner packed with Tenax TA [43]. They proposed the calculation of breakthrough volumes for the compounds to be enriched on the liner, and achieved this by connecting the PTV with packed liner directly to the detector without any separation column. In this way the PTV insert can be regarded as a short packed column and the specific breakthrough volume is defined as the volume of carrier gas, relative to 1 gram of adsorbent, needed to release the substance at the end of the column. This data coupled with similar data for the elimination behavior of water allowed them to inject 500 lal of aqueous standard solutions of pesticides and nitroaromatics with good recovery of analytes of interest. Mol and co-workers investigated the implications of liner dimensions on large volume solvent splitting [21 ]. Larger internal diameter liners can contain more solvent, and so require less fine control when introducing the solvent. On the other hand smaller internal diameter liners are more efficient during splitless transfer to the column and induce less breakdown of thermolabile substances.

Page 347: Instrumental

330

Figures 25 and 26 depict the schematics for a commercial PTV system which allows automated solvent venting (Gerstel, Miilheim an der Ruhr, Germany). All parameters including injection volume, injection speed and all PTV settings are controlled from Chemstation software. Electronic pressure control can be programmed for minimum column flow during venting to give minimum transfer of solvent to the column. The latest auxiliary gas control technology also controls the split purge flow, which can be automatically economised after the splitless transfer step of components for the chromatographic run. The large volume injector uses a standard Hewlett- Packard autosampler tray for automated sequence runs, and when this sampler is turned off the PTV automatically reverts to a standard cold split/splitless injector for low volume sample introduction.

Figure 25. Schematics for Gerstel PTV in solvent venting/stop flow mode.

Page 348: Instrumental

331

Figure 26. Schematics for Gerstel PTV in splitless mode.

The Gerstel large volume sampler is in fact a multipurpose sampler, in that it can be easily upgraded to a headspace injector or sampler. Static headspace injection is a valuable technique for determination of trace volatile compounds in foods and beverages. An initial drawback was the need to inject the large volume headspace vapour with splitting to produce sharp initial bands, and this in turn limited the sensitivity of the technique. A further aspect for consideration is that the process for transferring headspace vapour to a chromatographic column can involve significant dilution of the solutes with carrier gas. Takeoka and Jennings [44] attempted to solve this problem with a retractable on-column injector equipped with a fused silica needle syringe to allow gas sample injection directly into capillary columns. A dewar flask with coolant refocused the solutes

Page 349: Instrumental

332

in the first loop of the analytical column, while the sample matrix passed through. An important advantage of this instrumental configuration is the much more inert fused silica sample transfer path to the capillary column. Kolb [45] and Wylie [46] both used automated multi-sample headspace analysers but with whole column cryofocusing to allow splitless injection of the vapour. This apparatus allows multiple headspace injection, which involves several rapid headspace injections before the start of a chromatographic run. In this way the injections are superimposed by the cryofocusing and sensitivity can be dramatically increased. Barcarolo and colleagues [47] avoided cryogenic cooling and reconcentrated solutes by using a pre-column coated with graphitised carbon. This led from the headspace injector to a 3-way press-fit connector, linked to the analytical column and a vent line. Better peak shapes were obtained from splitless injections of ground coffee headspace, but recovery of highly volatile substances was not quantitative.

Use of the cooling functions of a PTV injector offers an elegant solution for the cryofocusing necessary for large volume headspace injection. In addition the liner can be packed with various adsorbents in order to act as a short pre-column with contributory retention capability. This approach was investigated by Poy and Corbelli [48] with additional evaluation of the trapping efficiences of various adsorbents. A carrier gas line and sample transfer tube pneumatically connected the headspace sampler to the GC. A probe end at the tip of the sample transfer tube entered through the septum of the PTV inlet port.

The Gerstel headspace sampler also uses the Gerstel PTV injector and has been designed to incorporate all the best features necessary for optimum headspace results. In particular the headspace transfer line to the PTV injector has been replaced by a gas tight autosampler syringe to provide a totally inert path for the sample. This system has a vial preheating module which allows each sample to be heated at the same temperature for the same length of time. For injection the sample is drawn from the headspace vial into the heated syringe and for multiple sampling from a single vial the syringe can be filled before each injection with a fixed volume of inert gas. To optimise the system for different application the following parameters can be individually programmed from the software :

- Sample preheating temperature.

- Sample preheating time.

- Internal delay for multiple injections.

- Vial filling with inert gas before each injection.

- PTV injection temperature profile.

- Needle penetration depth into the vial.

- Syringe filling speed during rinsing and sampling.

- Injection depth into the PTV for different liner types.

Similar to the large volume liquid injector the headspace sampler uses the standard Hewlett- Packard sample tray for up to one hundred 2 ml vials. Figure 27 shows 1,3 and 5 ml headspace injections of 10 pg/1 dimethyl sulfide and dimethyl disulfide in 20% aqueous ethanol with specific sulfur detection. For this analysis the PTV liner at -30~ was packed with a little Carbotrap during the headspace injections and a small split flow is established. After the single or multiple

Page 350: Instrumental

333

injections the system then switches automatically to splitless operation and the PTV is heated to transfer solutes of interest to the column. Using this technique the sensitivity increase over corresponding liquid injection can be 103, depending on the volatility of the solutes.

340000 �84

300000-

2 6 0 ( 0

220000

Analysis Condition.s: Headspace: Turret (Vial) 60~ Syringe 60~ Oven: 60~ 2~ to 80~ 5~ to 220~ Inj.: PTV,-50~ 10~ to 250~ SCD Carriergas: 20 cm/s He headspace transfer into PTV liner packed with Carbotrap at -50~ in split mode, then splitless transfer of compounds to column (2min)

340000

3(X)0(O-

260000

220000

340000-

300000-

260000

220000

Dimethyl Di su l f ide . ._ . 1 x 1 ml injected . . _ . . . . . _ - _ _

0 2 4 6 8 10 12 14 16

Dimethyl Sulfide

Dimethyl Disulfide

0 2 4 6 8 10 12 14

3 x I ml injected

�9 - , . ,

16

Dimethyl Sulfide

Dimethyl Disulfide

0 2 4 6 8 10 12 14

5 x 1 ml injected

�9 1'6 .... F igure 27. Specific sulfur traces of a headspace standard, l Oppb each dimethyl sulfide and dimethyl disulfide in 20% v/v ethanol, on 25m x 0.32mm x 5.011rn 5% Phenyl Methylsilicone column.

Page 351: Instrumental

334

Both detection limits and the functionality of the PTV can be further enhanced by incorporating its operation with a thermodesorption unit (Gerstel TDS-2) which itself can be temperature programmed. In this approach an adsorption tube containing the solutes of interest from a large volume purge and trap sampling is placed in the thermodesorption unit, which is connected directly to the PTV. The thermodesorption oven is then heated in a controlled programmed manner to desorb the components which are cyofocused in a cooled PTV liner [49-51 ]. Sample transfer to the column can be subsequently carried out in normal split or splitless mode of operation, with heating of the PTV. An interesting variant of this approach is to place the actual material for analysis (usually a solid) in an empty thermodesorption tube and purge the volatiles directly to the PTV for enrichment under cryofocusing. In this dynamic headspace approach the sample is kept at low heat but purged for an extended period to transfer the maximum amount of purgeable volatiles to the cooled PTV. Figures 28 and 29 show the nitrogen traces from a normal and a high colour speciality malt after this instrumental gas phase extraction and enrichment. The extra roasting involved in producing the high colour malt has generated a much higher proportion of flavour active nitrogen compounds.

800000-

Analysis Conditions: i Thermodesorption: 20~ 20~ to 80~

600000 Oven." 40~ 5~ to 170~ 15~ to 300~ lnj.: PTV,-150~ 12~ to 280~ NPD Carriergas." 100 kPa He

400000i thermal extraction transfer into PTV liner at -150~ in split mode, then splitless transfer of compounds to column (2min)

2oooooi

0 i0 2 0 30 40 50

Figure 28. GC-NPD trace of a normal malt after thermal extraction and PTV enrichment.

80(0)00

600000

4ooooo!

2oooooi

oi~ 0 10 20 30 40 50

Figure 29. GC-NPD trace of a high colour malt after thermal extraction and PTV enrichment.

Page 352: Instrumental

335

However Figures 30 and 31 show similar GC nitrogen traces of the extracts of the corresponding whiskeys from the same two malts, and using the same chromatographic separation conditions. Increased levels of nitrogen compounds are also evident in the whiskey from the high colour malt, but these are different more volatile compounds than those from the high colour malt itself. The additional conversion of starch to sugar inherent in this malt is most likely contributing to production of volatile nitrogen compounds via Maillard reaction during distillation of the fermented wash.

500000-

400000

30(0)00

200000 ~

10(0)00

Analysis Condition.s: _

Oven: 40~ 5~ to 170~ 15~ to 300~ Inj.: PTV, 60~ 12~ to 280~ NPD Carriergas: 100 kPa He llal split injection (1/30)

k._au__a___ ~ 1

0 10 20 30 40 Figure 30. GC-NPD trace of a whiskey extract from the normal malt.

50

500(0)0

40(0)00-

300000

200000

looooo

0 10 20 30 40 50

Figure 31. GC-NPD trace of a whiskey extract from the high colour malt.

MULTIDIMENSIONAL GAS CHROMATOGRAPHY It has been clearly pointed out by various authors [52, 53] that the resolution afforded by modem efficient capillary columns is really insufficient for separation of the component content of many real-life samples. A normal capillary column contains about 100,000 plates, but Giddings [52] calculates that 500 million theoretical plates would be required for 0.99 separation probability of a 100 component mixture. Viewed in a different way Smits [53] estimates that the total number of

Page 353: Instrumental

336

peaks that can be separated on the normal capillary column is only 0.1% of all known volatile compounds. By serially coupling capillary columns of different selectivities this basic resolution disadvantage can be dramatically lessened, and the subsequent appearance of a hidden world of compounds vividly highlights the limitation of one dimensional chromatography.

Many compounds still remain unidentified in distilled spirits and these most likely are trace compounds that remain undetected due to resolution difficulties in one dimensional capillary chromatography. It is also probable that these compounds could be important sensory contributors and progress in understanding perceived taste and aroma of spirits will require their separation and identification. Sample manipulation and fractionation of spirits can also produce enriched, highly contributory sub-fractions, but these are usually also enriched in many matrix compounds, and the basic resolution problem still remains. In our laboratory (K MacN) we have been working with a capillary two-dimensional hyphenated system for some years and in our experience two principle aspects are necessary for successful implementation of this approach in an industrial environment.

- The transfer of compounds should preferably be by the "valveless" technique, which uses pneumatic flow switching and balancing of gas pressures [54]. However if this pressure balancing is a manual time-consuming, trial and error procedure and not an automated user-friendly operation, it will not gain acceptance in routine laboratories.

- The construction of the hyphenated system should incorporate as much as possible existing GC and GC-MS hardware, and allow maximum flexibility and interconversion between use of the components as stand-alone units or linked to form the full system.

In the context of the latter point Figure 32 shows the stepwise build-up of a powerful 2-dimen- sional capillary system (Gerstel MCS-A) from an existing Hewlett-Packard GC-MSD and Chemstation. In the first step a second GC is added which functions as an additional oven to house a pre-column, and contains the column coupling device, the pressure and flow pneumatics for switching, and a heated interface through which the main column passes to join the pre- column in the first oven. The heated interface can be further upgraded to a cryotrap (CTS) for refocusing of volatile compounds, and the CTS itself can be upgraded to a cryo-enrichment device (CTE) which allows coupling of different diameter columns with each retaining its optimum gas velocity. Finally a PTV injector with an optional multipurpose sampler (large volume or headspace) can be added to either of the two GC ovens. When added to the first oven the additio- nal second separation dimension becomes possible and an example using initial large volume headspace injection is shown later.

Modem GC and GC-MS Chemstation software is both multi-instrument and multi-tasking and this attribute can be used to good advantage for maximum flexibility of such a hyphenated system. This means that when not being used for 2-dimensional work the total system is in effect a collection of separate units, all working independently and simultaneously, and controlled from the Chemstation. The first oven could be running a GC-ECD analysis on an apolar column, and the second oven operating in GC-MSD on a polar column. If PTV injectors (Gerstel CIS-3) are fitted to one of both ovens then large volume injection with solvent elimination, or headspace or thermal desorption with PTV cryofocusing is also possible. Control of all these devices is also via the Chemstation under MS Windows.

Page 354: Instrumental

337

4

2_

Existing GC/MSD with PTV I : P T V 2: Existing GC 3: Main Column 4: MSD 5: PC

5

r

4

Add GC/PTV with column switching hardware and pneumatics

6: New GC 7: Column Switching Device 8: Monitor Detector 9: Precolumn 10: Heated Interface

, 7I Upgrade interface to allow both heating and cooling

1 O: Cryotrap

V 5

7

4

Upgrade cryotrap with enrichment option

11: Enrichment Device

f

Add multipurpose sampler for large volume liquid and headspace injection or thermal desorption system to either PTV injector

12: Multi Purpose Sampler or Thermal Desorption System

Figure 32. Modular build-up of a 2-dimensional GC/MSD system.

Page 355: Instrumental

338

Conversion to a two-dimensional unit, and optional deconversion back to independent operation, must be simple and rapid to maintain the overall flexibility of such a system. This is achieved by means of a unique column switching device which couples both columns, and computer controlled pneumatics for automatic pressure equilibration after transfer of components. The miniature switching device remains as a permanent fixture in the first oven and the specialised pneumatics are also factory installed, so that only additional column connections and Chemstation parameter entries are required during conversion. Column connections in the switching device are with Graphpack technology which assures leak-free coupling.

Figure 33 shows the switching principle in the column switching device. The zero condition is defined as an uninterrupted carrier gas flow through both columns and this implies total transfer. Compounds of no interest are prevented reaching the main column by a countercurrent venting flow through the switching device supplied by an electronic mass flow controller. This must be greater than the carrier gas flow and functions both to vent unwanted components and supply the original zero condition carrier gas flow in the second column. Therefore this venting flow is normally activated and must be switched off for transfer of compounds to the second column.

Figure 33. Switching principle in column switching device.

The venting flow line exists from the switching device to an electronic equilibration proportional valve with a build-in pressure sensor (Figure 34). This unit continually reads the pressure at the column switching device and automatically re-equilibrates during transfer of compounds without any operator need for repetitive pressure manipulations. The only Chemstation parameter entries required are the initial zero condition pressure and the desired compound transfer times.

Page 356: Instrumental

339

Figure 34. Flow scheme of Gerstel switching pneumatics.

Figure 35 shows the additional pneumatics required when transfer operations with columns of different dimensions (0.53 mm pre-column to 0.25 mm main column) are required. Here again an electronic proportional valve is used but without a mass flow controller so that the action of the valve is to automatically and continuously effect a carrier gas split flow to achieve a pressure reduction before the main column to allow its optimum carrier gas velocity. This allows a high flow through a high capacity megabore precolumn and a low optimum flow through a narrow bore main column which could be connected to an MS. Compounds are transferred at the precolumn flow rate and trapped in the cryointerface. The pressure reducing split flow is then temporarily turned off for temperature programmed transfer of these compounds to the main column.

Figure 35. Flow scheme of Gerstel pneumatics to couple columns of different diameters (cryotrap enrichment option).

Page 357: Instrumental

340

MacNamara used such a system with automatic pressure equilibration to investigate medium boiling sulfur compounds in whiskey [55]. The compounds were first isolated and enriched from whiskey using a combination of fractional distillation and preparative GC. This process however also resulted in a complex matrix of non-sulfur compounds which would have made mass spectrometric identification very difficult. Therefore the compounds of interest were located on a polar precolumn of a two-dimensional configuration and cut in groups to an apolar main column. By establishing a sulfur trace with retention times for each of these cuts on the main column (Figure 36), and then repeating each cut to an MSD, clean mass spectra for all the compounds of interest could be recorded. This procedure led to the identification of a number of new sulfur compounds [55, 31 ].

Figure 36. Polar to apolar cutting of whiskey sulfur compounds with alternate FID and SCD detection on pre- and main column.

Page 358: Instrumental

341

Van Ingen and co-workers used a two-dimensional approach to detect and quantify the restricted compound ethyl carbamate at the ppb level in alcoholic beverages [56]. The sample was extracted with dichloromethane and after concentration and injection the ethyl carbamate was heart-cut from an apolar to a polar column. An FID detector could be used after the second column and the much increased resolution on the second column prevented false positive results. MacNamara and Hoffmann also determined ethyl carbamate in whiskey using a two-dimensional approach but with large volume direct injection and selected ion monitoring after the second column [57]. 20 lal of spirit could be injected into a PTV liner with solvent venting and the majority of the ethyl carbamate content was retained for transfer to the chromatographic system. This combination of large volume injection and selected ion monitoring resulted in reproducible quantification at the 5 lag/l level with three ion target confirmation of positives.

When headspace injection is used with PTV for large volume vapour sampling significant sensitivity advantages can be achieved. Figure 37 shows the FID and specific sulfur traces of the volatile fraction of a whiskey on a thick film polar capillary after injection of 5 ml of headspace vapour to a cooled PTV injector.

Figure 37. 5 ml headspace injection of whiskey volatiles, precolumn chromatograms, FID- (top) and sulfur trace on 50m x 0.53mm x 1.Ol~m Carbowax 20M.

Page 359: Instrumental

342

When the same sample is injected as a liquid the same trace outline is obtained but with areas less by a factor of 100. The indicated cut region, which contains two sulfur compounds, is then transferred with cryofocusing to a thick film apolar column in the second oven and Figure 38 shows the corresponding FID and sulfur trace of the cut. Both sulfur compounds are recovered with increased resolution for spectral investigation, and the complexity of the FID trace after cutting highlights the hidden complexity of the sample [58].

12000

1 0 ( ~

8000-

6000-

4000-

FID-trace

Sulfur II l[ II Compoundllll

�9 ~ . . . - - - - - n

0 5 10 15 20

400000-

300000-

20(0)00-

10(0)O

Analysis Conditions: Oven: -50~ cut), 70~ to 60~ 2~ to 80~ 5~ to 220~ Det.: FID and SCD Carriergas: 20 cm/s He

SCD-trace

0 5 f0 15 20

Figure 38. FID (top) and sulfur trace on 25m x 0.32mm x 5.01am 5%Phenyl Methylsilicone column (main column).

Multidimensional capillary GC can also be used to preparatively isolate pure compounds from complex mixtures. In Figure 39 the first trace (A) shows the separation of a concentrate of yeast extract volatiles, and peaks numbered 1,2 and 3 could not be identified by GC-MS. These unknown compounds were then isolated as pure substances by repetitive injection, cutting, and trapping in a 2-column system (B and C). Regions of interest are transferred from the pre-column to the main column, and after separation on the main column, the single compounds are further cut and isolated in cooled glass traps [59]. After 55 injection cycles sufficient amounts of pure components were available to allow structure elucidation by 1H-NMR, IR and MS.

Page 360: Instrumental

1

343

jL A: Analytical Separation

Figure 39. Isolation of cis- and trans-2,4,5-trimethyl-5-hydroxy-3-thiazoline and 2-isobutyl- 4,5-dimethyl-3-thiazoline from yeast extracts.

Page 361: Instrumental

344

REFERENCES 1 D. de Rijke and R. ter Heide; Flavour Compounds in Rum, Cognac and Whiskey; Flavour of Distilled

Beverages, Ellis Horwood Limited (1983). 2 P. Salo, L. Nykanen and H. Suomalainen; Odour Thresholds and Relative Intensities of Volatile Aroma

Compounds in an Artificial Beverage Imitating Whiskey; J. Food Sci. (1972), 37, 394-398. 3 R. Duncan and J. Philp; Methods for the Analysis of Scotch Whiskey; J. Sci. Fd. Agric. (1966), 17,

208-214. 4 R.L. Brunelle; Collaborate Study of the Quantitative Determination of Fusel Oil and Ethyl Acetate by Gas

Liquid Chromatography; J. Assoc. Anal. Chem (1968), 5"/, 915-921. 5 J. Kahn and E. Blessinger; Collaborate Study of the Quantitative Gas Liquid Chromatographic

Determination of Fusel Oil and Other Components in Whiskey; J. Assoc. Anal. Chem. (1972), 55, 549-556.

6 M. Cabezudo, E. Corostiza, M. Herraiz, J. Fernandez-Biarge, J. Garcia-Dominguez and M. Molera; Isothermal Selective Separation of Alcoholic and Acetic Fermentation Products; J. Chr. Sci. (1978), 16, 61-67.

7 A. DiCorcia, R. Samperi and C. Severini; Modified Graphitized Carbon Black for the Gas Chromatographic Analysis of Alcoholic Beverages; J. Chromatography (1979), 170, 245-248.

8 G. Martin, J. Burggraff, R. Dyer and P. Buscemi; Gas Liquid Chromatographic Determination of Congeners in Alcoholic Products with Confirmation by Gas Chromatography/Mass Spectrometry; J Assoc. Anal. Chem. (1981), 64, 186-190.

9 Restek Corporation; The Restek Advantage (1994), Vol. 5, No. 4. 10 L. Gonzalez and R. Gonzalez-Lara; Selective Separation of Alcoholic Beverages and Distilled Wines by

Gas Chromatography; J. Chr. Sci. (1994), 32, 195-198. 11 W. Jennings; Modem Methods in Food Analysis; AVI Publishing Company, Inc. (1984), Chapter 13. 12 K. Grob, H. Neukom and H. Kaderli; Higher Alcohols in Alcoholic Beverages by Direct Analysis on Glass

Capillary Columns; J. High Res. Chr. (1978), 1, 98. 13 R. de Nijs and J. de Zeeuw; A Chemically Bonded Polyethylene Glycol Stationary Phase for Gas

Chromatography; J. High Res. Chr. (1982), 5, 501. 14 K. MacNamara; Rapid Determination of Major Congeners in Distilled Spirits by Direct Analysis on Bonded

Capillary Columns; J. High Res. Chr. (1984), 7, 641. 15 M. Masuda, M. Yamamoto and Y. Asakura; Direct Gas Chromatographic Analysis of Fusel Alcohols,

Fatty Acids and Esters of Distilled Alcoholic Beverages; J. Food Sci. (1985), 50, 264-265. 16 K. MacNamara and N. Burke; Determination of Free Fatty Acids and Other Major Congeners in Distilled

Spirits by Direct Analysis on a Bonded FFAP Capillary Column; J. High Res. Chr. (1985), 8, 853-855. 17 Irish Distillers Group Ltd., Internal Report. 18 G. Reglero, M. Herraiz and M. Cabezudo; Sampling in Capillary Gas Chromatography: A Comparison

between the Split and the PTV-Split Procedures; Chromatographia (1986), 7-12, 333-336. 19 K. Eder, A. Reichlmayr and M. Kirchgessner; Gas Chromatographic Analysis of Fatty Acid Methyl Esters:

Avoiding Discrimination by Programmed Temperature Vaporizing Injection; J. Chromatography (1991), 588, 265-272.

20 J. Requeiro, I. Diaz, E David and P. Sandra; Possibilities of PTV Injection for the Analysis of Triglycerides; J. High Res. Chr. (1994), 17, 180-183.

21 H. Mol, H.-G. Janssen, C. Cramers and U. Brinkman; Large Volume Sample Introduction Using Temperature Programmable Injectors: Implications of Liner Diameter; J. High Res. Chr. (1995), 18, 19-27.

22 Target 3.2 Operators Manual; Thru-Put Systems, Inc., P.O. Box 617290, Orlando, Florida 32861-7290, USA.

23 G. Hagman and J. Roeraade; Rapid Determination of Volatiles in Alcoholic Beverages by Precolumn- Backflush Gas Chromatography; J. High Res. Chr. (1989), 13, 99-103.

24 K. Shiomi; Determination of Acetaldehyde, Acetal and Other Volatile Congeners in Alcoholic Beverages Using Multidimensional Gas Chromatography; J. High Res. Chr. (1991), 14, 136-137.

25 H. Mandery; Gaschromatographisch-Massenspektrometrische Untersuchung fliichtiger lnhaltsstoffe des Traubenmost- und Weinaromas: Auswirkung der Siissung auf die A romazusammensetzung; Dissertation Univ. Karlsruhe, Germany (1983).

Page 362: Instrumental

345

26 A. Rapp, I. Yavas and H. Hastrich; Einfache und schnelle Anreicherung (,,Kaltronmethode") von Aroma stoffen des Weines und deren quantitative Bestimmung mittels Kapillargaschromatographie; Deutsche Lebensmittel-Rundschau (1994), 90, 171-174.

27 A. Rapp, H. Hastrich, I. Yavas and H. Ullemeyer; Zur einfachen, schnellen Anreicherung (,,Kaltronmethode") und quantitativen Bestimmung von fliichtigen lnhaltsstoffen aus Spirituosen; B ranntweinwirtschaft (1994), 1, 286-289.

28 E Liddle and A. Bossard; The Analysis of Wines and Spirits by Capillary Gas Chromatography; Alcoholic Beverages, Elsevier Applied Science Publishers (1984), Chapter 7.

29 R. ter Heide, E de Valois, J. Visser, P. Jaegers and R. Timmer; Concentration and Identification of Trace Constituents in Alcoholic Beverages; Analysis of Food and Beverages, G. Charalambous (ed.), New York (1978), 249-287.

30 R. ter Heide; Instrumental Analysis of Alcoholic Beverages; Proceed. Syrup. on Flavour Research of Alcoholic Beverages, L. Nyk/inen and E Lekkonen (ed.), (1984), 149-165.

31 T. Taniguchi, N. Myajima and H. Komura;An Application of Centrifugal Counter-Current Chromatography on Flavour Chemistry: Separation of Aroma Substances in Whiskey New Distilled.

32 J. Hinshaw; Very-Large-Volume Injection; LC-GC International (1994), Vol 7, No. 10. 33 K Grob; Solvent Effects in Capillary Gas Chromatography; Proceed. 5th Int. Symp. on Capillary

Chromatography, Elsevier Scientific Publishing Company (1983), 254-265. 34 K. Grob; Classical Split and Splitless Injection in Capillary GC; Hiithig Verlag, Heidelberg, Germany

(1986). 35 W. Vogt, K. Jacob and H. Obwexer; Sampling Methods in Capillary Column GLC Allowing Injections of

up to 250/~l; J. Chromatography (1979), 174, 437-439. 36 W. Vogt, K. Jacob, A.-B. Ohnesorge and H. Obwexer; Capillary GC Injection System for Large Sample

Volumes; J. Chromatography (1979), 186, 197-205. 37 K. Grob; PTV-Vapor Overflow - Principles of a Solvent Evaporation Technique for Introducing Large

Volumes in Capillary GC; J. High Res. Chr. (1990), 13, 540-546. 38 H. Mol, H.-G. Janssen, C. Cramers and U. Brinkman; Use of a Temperature Programmed Injector with a

Packed Liner for Direct Water Analysis and On-Line Revesed Phase LC-GC; J. High Res. Chr. (1993), 16, 459-463.

39 M. Herraiz, G. Reglero, E. Loyola and T. Herraiz; Sampling of Volatile Components Using a PTV in the Solvent Split Mode; J. High Res. Chr. (1987), 10, 598-602.

40 J. Villen, T. Herraiz, G. Reglero and M. Herraiz; Experiments with the PTV in the Solvent Split Mode for Concentration of Volatiles; J. High Res. Chr. (1989), 12, 633-635.

41 K. Grob; On-Column Injection in Capillary Gas Chromatography; HiJthig Verlag, Heidelberg, Germany (1987).

42 J. Staniewski and J. Rijks; Solvent Elimination Rate in Temperature Programmed Injections of Large Sample Volumes in Capillary Gas Chromatography; J. Chromatography (1992), 623, 105-113.

43 S. Miiller, J. Efer and W. Engewald; Gas Chromatographic Water Analysis by Direct Injection of Large Sample Volumes in an Adsorbent-Packed PTV Liner; Chromatographia (1994), 38, 694-700.

44 G. Takeoka and W. Jennings; Developments in the Analysis of Headspace Volatiles: On-Column Injections into Fused Silica Capillaries and Split Injections with a Low-Temperature Bonded PEG Stationary Phase; J. Chr. Sci. (1984), 22, 177-184.

45 B. Kolb and B. Liebhardt; Cryofocussing in the Combination of Gas Chromatography with Equilibrium Headspace Sampling; Chromatographia (1986), 21, 305-311.

46 P. Wylie; Headspace Analysis with Cryogenic Focussing: A Procedure for Increasing the Sensitivity of Automated Capillary Headspace Analysis; Chromatographia (1986), 21, 251-258.

47 R. Barcarolo and P. Casson; Volatile Enrichment on Automatict Static Headspace Using a Precolumn and Stopping the Carrier Gas Flow During Injection; J. High Res. Chr. (1995), 18, 5-8.

48 F. Poy and L. Corbelli; Automatic Headspace and Programmed Temperature Vaporizer (PTV) Operated in Cryo-Enrichment Mode in High Resolution Gas Chromatography; J. Chr. Sci. (1985), 23, 114-119.

49 A. Hoffmann and R. Bremer; Design, Performance and Applicability of a Multi-Functional Thermal Desorption System for Trace Analysis in Capillao, GC; Proceed. 16th Int. Symp. on Capillary Chromatography, E Sandra and G. Devos (ed.), Riva del Garda, Italy (1994), 1165-1175.

Page 363: Instrumental

346

50 A. Hoffmann and W.R. Sponholz; Direct Thermal Analysis of Solids - A Fast Method for the Determination of Halogenated Anisols and Phenols in Cork; Proceed. 16th Int. Symp. on Capillary Chromatography, P. Sandra and G. Devos (ed.), Riva del Garda, Italy (1994), 1011-1020.

51 H. W6rmann and A. Hoffmann; Trace Analysis of PAH's and PCB's in Soil through On-Line Direct Thermal Desorption; Proceed. 16th Int. Syrup. on Capillary Chromatography, P. Sandra and G. Devos (ed.), Riva del Garda, Italy (1994), 416-424.

52 J. Giddings; Multidimensional Chromatograph), Techniques and Applications; Marcel Dekker, Inc. (1990). 53 R. Smits; Hyphenation - An Overview; LC-GC International (1994), Vol. 7, No. 9, 505-508. 54 D. Deans; A New Technique in Heart-Cutting in Gas Chromatography; Chromatographia (1968), 1,

18-22. 55 K. MacNamara; Investigation of Medium Boiling Sulfur Compounds in Whiskey; Elaboration et

Connaissance des Spiritueux, Lavoisier-Tec et Doc, R. Cantagrel (ed.), Paris (1993). 56 R. van Ingen, L. Nijssen, E. van den Berg and K. Maarse; Determination ofEthyl Carbamate in Alcoholic

Beverages by Two-Dimensional Gas Chromatograph)'; J. High Res. Chr. (1987), 10, 151-152. 57 K. MacNamara and A. Hoffmann; Use of a GC/MSD Multi Column Switching System for Direct

Determination of Ethyl Carbamate in Alcoholic Beverages with Three Ion Confirmation of Positives; Proceed. 13th Int. Symp. on Capillary Chromatography, P. Sandra (ed.), Riva del Garda, Italy (1991), 1662-1672.

58 Irish Distillers Group Ltd., Internal Report. 59 P. Werkhoff, W. Bretschneider and S. Brennecke; Multidimensional Preparative Capillary Gas

Chromatography in Flavour Research; Gerstel Aktuell (1991), No. 12, Gerstel GmbH, Aktienstrasse 232-234, 45473 Miilheim an der Ruhr, Germany.

Page 364: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 347

Analytical methods for color and pungency of chiles (capsicums).

M.M. Wall and P.W. Bosland

Department of Agronomy and Horticulture, New Mexico State University, Box 30003, Las Cruces, New Mexico, United States

INTRODUCTION

Worldwide, there are thousands of chile varieties varying widely in their size, shape, color, flavor, and pungency level. The uses for these chiles are equally as diverse as the fruit types in the Capsicum genus. Chile fruit are primarily consumed as a fresh vegetable or dehydrated for use as a spice. However, the range of food products that contain chile or its chemical constituents is broad, and includes ethnic prepared foods, meats, salad dressings, mayonnaise, dairy products, beverages, candies, baked goods, snack foods, breadmgs and batters, salsas and hot sauces. Chile extracts are also used in pharmaceutical and cosmetic products. Quality standards differ for these varied products, especially in the food industry. However, almost all fresh or dried chile is evaluated for color and pungency at several stages, from harvest and preprocessing, to f'mal product formulation.

The yellow, orange and red chile colors originate from the carotenoid pigments produced in the fruit during ripening. Over 25 different pigments have been identified in chile fruits (1). These pigments include the green chlorophylls (a and b); the yellow- orange lutein, zeaxanthin, violaxanthin, antheraxanthin, [3-cryptoxanthin and [3- carotenes; and the red pigments, capsanthin, capsorubin and cryptocapsin, that are distinctive to Capsicums. Chile carotenoids are important not only as food colorants, but also for their immense nutritive value. The capsanthin, capsombin and cryptocapsin pigments are valued mostly as natural colorants, whereas B-carotene, a-carotene, y- carotene and 13-cryptoxanthin have provitamin A activity. These provitamin A carotenoids are essential to human nutrition, and the oxygenated carotenoids (xanthophylls) have been studied as anti-cancer agents (2).

Besides color (carotenoids), another important quality attribute of Capsicum is pungency (heat). Some have argued that pungency is one of the five main taste sensories, along with bitter, sweet, sour, and salty. Physiologically, the senses responsible for our perception of flavor can be divided into three anatomical systems. In the oral cavity, the classical gustatory pathways through the tongue and soft palate are responsible for our sensitivity to the four basic tastes, sweet, sour, salty, and bitter. In the nasal passages, the olfactory receptors provide sensitivity to a wide variety of volatile compounds, producing the sensations we normally assign to smell. In addition to these two systems, the trigemmal nerves in both the oral and nasal cavities provide

Page 365: Instrumental

348

sensitivity to thermal, tactile, irritation, and pare sensations (3). The trigeminal innervation is also chemically sensitive to compounds that are pungent, and hence provide an important part of our appreciation of flavor as a whole. Because the capsaicmoids are potent stimuli of the oral trigemmal nerves they are a desirable attribute of many foods. In most parts of the world, pungency increases the acceptance of the insipid basic nutrient foods.

The word "pungency" can be confusing. Some prefer "hot flavor", heat, fiery, or spicy to that of pungency. In this chapter, the sensory response will be identified as pungency and the substance responsible for pungency by its chemical name, capsaicm, dihydrocapsaicin, etc. The capsaicmoids can be analyzed or estimated by their physical or chemical characteristics, but the pungency of a chile product can only be validated through a correlation with the perceived heat associated with oral consumption. This has become very relevant in recent years because of the complexity of the food items containing capsaicmoids.

There is a preference for specific levels of pungency in internationally traded chile products, and with paprika, the absence of pungency is important. Red chile and paprika are dehydrated and sold as whole pods, or ground into powder. The dried red powder is classified into five groups based on pungency level: non-pungent or paprika (0 to 700 scoville heat units), mildly pungent (700 to 3,000), moderately pungent (3,000 to 25,000), highly pungent (25,000 to 70,000) and very highly pungent (>80,000). The very highly pungent powder is mainly grown in Asia. Paprika may be obtained from any one of many types of C. annuum. However, in the United States, it is considered a product, not a pod-type. The Hungarian word for Capsicum is "paprika." Thus, Hungarian paprika may be pungent or non-pungent, depending on the cultivar. Other areas where a knowledge of individual capsaicmoid content is useful are taxonomic, breeding, medicinal, and biosynthetic research purposes.

In this chapter, analytical methods for determining chile color and pungency are described. Early methods estimated the total concentrations of either pigment or pungency compounds using sensory evaluations or spectrophotometry. These techniques were primarily used for quality control checks in the food industry. However, as the food industry has evolved and become more competitive, precise methods to analyze quality components are necessary. High performance liquid chromatography (HPLC) facilitates the accurate separation and quantification of chile quality components. HPLC is rapidly replacing older methods of compositional analysis by the food and medicinal industries, especially in the area of pungency analysis.

CHILE COLOR ANALYSIS

Chile color can be evaluated from 3 different perspectives: surface color, extractable color, and carotenoid profiles. Surface color is a measurement of the visual color perceived by the viewer. It is sometimes referred to as reflective color. Surface

Page 366: Instrumental

349

color varies according to cultivar, growing conditions, dehydration and storage conditions, and the coarseness of ground samples. Surface color measurements are important when dehydrated chile is to be used as a retail spice or as a coating on foods. Extractable color is a measurement of total pigment content. Extractable color analyses are useful when chile is added as an ingredient or colorant in oil-based foods, cosmetics, or pharmaceuticals. Extractable color and surface color measurements are standard quality evaluations in the spice industry. Analytical methods that separate and quantify individual chile carotenoids, providing pigment profiles, are used mostly for research and development. HPLC is the most accurate method and is being used increasingly by oleoresm, drug, and vitamin manufacturers for routine analysis.

Measuring Surface Color

Surface color measurements are used to specify colors perceived by the human eye. Verbal descriptions of colors can be difficult and confusing, because two people may describe the same color in very different terms. The perception of color varies according to the sensitivity of an individual's eyes, the size of the object being viewed, the light source for illumination, the background color and contrast, and the angle at which an object is viewed. Quantifying colors, or expressing colors numerically, facilitates color communication and standardization. Visual color can be quantified using a colorimeter (color difference meter or chromameter). Several colorimeters are available including the Gardner color difference meter, the Hunter colorimeter and the Minolta chromameter. The older colorimeter models are typically large instruments that are confined to laboratory use. Several portable models are now available such as the Hunter Miniscan (Reston, VA), the X-Rite 918 (Grandville, MI) and the Mmolta CR- 300 series (Ramsey, NJ) (4). These instruments enable the capsicum industry to quantify, and therefore set standards for, surface color.

The Commission Intemationale de rEclairage [(CIE) International Commission on Illumination] established a tristimulus color system commonly used for surface color measurements (5). The tristimulus values, XYZ, were based on the theory that the eye possesses receptors for three primary colors (red, green, blue), and that all other colors are perceived as mixtures of these primary colors. The XYZ values were determined from color-matching functions that corresponded to the eye's sensitivity at various wavelengths of the visible specmun. The CIE developed the Yxy color space from the tristimulus values. The Yxy color space (a numerical expression of color) was improved to the L'a'b" system (5). The L'a'b" (CIELAB) color space is the most widely used system today. This system is based on a 3-dimensional color space with 3 coordinates (L'a*b'). In the CIELAB system, color is represented spherically.

The elements of perceived color are lighmess, hue, and chroma and they are determined from the L'a'b" coordinates. The L ~ coordinate measures the value or lighmess of a color and is located on the central (vertical) axis of the CIELAB color space. This axis is achromatic and ranges from black (0) at the bottom to white (100)

Page 367: Instrumental

350

at the top. The a* and b* values are chromaticity coordinates and indicate directions away from the center of the color sphere. The a* coordinate denotes red when positive and green when negative, and b" denotes yellow when positive and blue when negative. Hue angle (h ~ and chroma (C) can be determined from the a* and b* coordinates. The hue and chroma color aspects are easier to conceptualize than a* and b* values (6). Hue sets the kind of color (red, yellow, blue, green, etc.) and equals the arctangent b'/a*. At any horizontal cross-section of the color sphere, all hues are represented in a 360 degree circle (the color wheel). A sample with a hue angle of 0 ~ is purplish-red, 90 ~ is yellow, 180 ~ is bluish-green and 270 ~ is blue (4). Paprika samples typically have hue angles between 30 ~ and 45 ~ , which is the range of red to orange on the color wheel. Chroma is a measure of color saturation or purity. A sample with a high chroma is more vivid than one with a low chroma value, even though both samples may have the same hue. Colors located near the central axis of the color space have low chromas that indicate dull, achromatic colors, with more gray. Colors located near the periphery of the color space are vivid. Chroma (C) is calculated from the square root of the sum of @)2 and (b*) z

The capsicum industry can use these surface measurements to compare the quality of lots or to set specifications for their products. Quality control technicians may determine the optimum hue, chroma, and value for their product and communicate this information to suppliers. For example, a sample with a hue angle of 30 ~ and a chroma of 50 would be reddish-orange and bright. However, a sample with a hue angle of 45 ~ and a chroma of 30 would be a dull, orange color. An understanding of the elements of color makes communicating and comparing surface color standards less complicated and more consistent for producers and processors.

Measuring Extractable Color-Total Pigment Content

The market value of paprika depends largely on its color intensity, because paprika and its oleoresm are used principally as natural coloring agents. Therefore, the spice industry requires a simple, reproducible method for measuring the total content of red and yellow pigments in dehydrated capsicums. In an early method for estimating the red pigments in paprika, a visual comparison between a sample extract and a standard solution of potassium dichromate and cobaltous chloride was made by panelists (7). The Essential Oil Association of America (EOA) adopted a standardized color matching method to determine color values of capsicum oleoresins. This visual matching method was subjective and was eventually replaced by spectrophotometric methods (8).

Current procedures for measuring extractable color (total pigments) in dehydrated capsicums and oleoresms were developed and approved by the Association of Official Analytical Chemists (9, 10) and the American Spice Trade Association (11). Extractable color is measured using a spectrophotometer and is designated in ASTA units. Generally, the higher the ASTA color value, the greater the effect on the

Page 368: Instrumental

351

brightness or richness of the final product. Paprika with 200 ASTA color units would give a brighter red to a finished product than an equivalent amount with 100 ASTA color units.

ASTA method 20.1 is the procedure used by the capsicum industry in the United States. The technique is simple, does not require complex equipment, and is relatively inexpensive. To analyze for color, dried capsicums are first ground to pass through a 1-mm sieve. Between 70 and 100 mg of the sample is weighed and transferred to a 100-mQ volumetric flask. Acetone (100 m0 is added to the flask, and the flask is stoppered, shaken, and allowed to stand for 16 hours in the dark. The color intensity of the extract is measured using a spectrophotometer set at a 460 nm wavelength and calibrated with an acetone blank. A portion of the sample extract is transferred to a spectrophotometer cuvette, and the absorbance is measured and recorded. The absorbance of the extract should be between 0.30 and 0.70.

A standard glass filter (Standard Reference Material 930d, National Institute of Standards and Technology, USA) is used in ASTA method 20.1 to account for instrument variability. The previous ASTA method (20.0) used a chemical color solution (potassium dichromate/coboltous chloride) for standardizing the instrument. The absorbance of the standard glass filter is measured at 465 nm, and an instrument correction factor (If) is calculated by dividing the absorbance reported by the NIST, by the absorbance recorded on the instrument being used. The absorbance of the glass filter should be determined each time the instrument is turned on. ASTA units are calculated for the sample extract using the formula:

ASTA color - Absorbance of the sample extract x 16.4 x If Sample weight in grams

The ASTA/AOAC method measures total pigment content without differentiating between the concentrations of red and yellow pigments. In a method described by Baranyai and Szabolcs (12), the total pigment concentrations can be partitioned into contributions by the red and yellow components. The method is based on the reduction of the red pigments with sodium borohydride to produce yellow pigments. An increase in absorption at the maxima for the yellow pigments is determined to provide a more exact measurement of total pigment concentration.

In the Baranyai and Szabolcs reduction method, paprika powder (0.5g) is extracted with 100 mQ of benzene on a shaker for 30 minutes. A 10 mQ portion of the extract is diluted to 50 mQ. The diluted extract (10 mQ) is mixed with 10 mQ of 96% ethyl alcohol and divided into two test tubes. Sodium borohydride is added to one of the test tubes, and after 40 minutes, sodium hydroxide is added and the solution turns yellow. The solution is filtered and the absorbance is measured at 455 nm using a spectrophotometer. The absorbance of the unreduced solution in the second test tube is measured at 510 nm, (the absorption maxima of the major red pigments, capsanthin and capsorubm) and compared to the absorbance of the reduced solution at 510 nm.

Page 369: Instrumental

352

Using this method, pigment concentrations can be calculated as follows: red carotenoids (mg/g) = 1.5 As10 x D and total carotenoids (mg/g) = A455 x D. Ill these calculations, As~0 and A455 are the absorbances measured at the respective wavelengths, and D is the dilution factor. The concentration of yellow pigments can be determined from the difference between total pigment concentration and red pigment concentration.

Carotenoid Biosynthesis

The diverse and brilliant colors of chile fruit originate from the carotenoid pigments present in the thylakoid membranes of the chromoplasts. In plants, carotenoids are synthesized in both the chloroplasts of photosynthetic tissues and the chromoplasts of flowers, fruit and roots. Chemically, carotenoids are lipid-soluble, symmetrical hydrocarbons with a series of conjugated double bonds. The double bond structure is responsible for the absorption of visible light. Carotenoids function as accessory pigments for photosynthesis, but more importantly, as photoprotectants in the plant. The primary function of 13-carotene and other carotenoids is to protect the chloroplasts from photo-oxidative damage. In flowers and fruit, carotenoids are important for the attraction of pollinators and seed dispersers.

Carotenoids are tetraterpenoid (C40) compounds synthesized from eight isoprenoid units. Three molecules of the primary metabolite, acetyl-coenzyme A, form mevalonic acid that is a precursor to the C5 compound, isopentenyl pyrophosphate. Isopentenyl pyrophosphate is the precursor to plant terpenoids, and through a sequence of chain elongations forms geranyl pyrophosphate (C10), famesyl pyrophosphate (C~5) and geranyl-geranyl pyrophosphate (C20). Two molecules of geranyl-geranyl pyro- phosphate form the intermediate, prephytoene pyrophosphate, and then phytoene (C40). Pytoene is desaturated through a series of reactions into lycopene (C40H56) , the direct precursor to carotenoids. Lycopene undergoes cyclization reactions to form the cyclic carotenes (i.e. [3-carotene) (13-16).

The enzymes catalyzing the conversion of isopenteny! pyrophosphate into phytoene have been studied and identified, because they are not membrane-bound. They include isopentenyl pyrophosphate isomerase, geranyl geranyl pyrophosphate synthase (GGPS) and phytoene synthase. GGPS catalyzes three condensation reactions in the conversion of isopentenyl pyrophosphate to geranyl geranyl pyrophosphate (13). GGPS has been purified from Capsicum chromoplasts, and cDNA encoding for GGPS activity has been isolated (17, 18). Phytoene synthase catalyzes the reactions forming prephytoene pyrophosphate and phytoene and also has been isolated from Capsicum (19, 20). The enzymes involved in the subsequent desaturation of phytoene to lycopene, cyclization of lycopene to carotenes, and further hydroxylation steps are tightly membrane-bound, making study more difficult. However, some of these enzymes have been isolated from Capsicum chromoplasts. Phytoene desaturase (PDS) catalyzes four desaturation steps from the colorless phytoene to the orange-red

Page 370: Instrumental

353

lycopene, and lycopene cyclase forms the cyclic carotenoids (13). Phytoene desaturase has been isolated from Capsicum (21) and lycopene cyclase activity has been demonstrated in Capsicum chromoplasts (22).

Following formation of the cyclic carotenes, 13-carotene is hydrolyzed into the xanthophylls, cryptoxanthin, and zeaxanthin. Xanthophylls are oxygenated derivatives of carotenes. Zeaxanthin undergoes epoxidation to form antheraxanthin (zeaxanthin monoepoxide) and violaxanthin (zeaxanthin diepoxide). These xanthophyll epoxides are the direct precursors to the unique red carotenoids of chile fruits. Red chile fruits synthesize the cyclopentenyl keto-carotenoids, capsanthin, capsorubm and crypto- capsm, in the chromoplasts. Cryptocapsin is formed from cryptoxanthm through the intermediate, cryptoxanthm-5,6-epoxide. Antheraxanthm undergoes rearrangement to form capsanthin, the most abundant red keto-carotenoid in chile fruits, and a small amount of capsorubm. Violaxanthin is the primary pathway for capsorubin synthesis. (23). The enzymes involved in xanthophyll biosynthesis remain unknown, but the enzyme catalyzing the conversion of antheraxanthin and violaxanthin to capanthin and capsorubm has been purified and cDNA has been isolated (24).

Separation and Quantification of Carotenoids

A strong interest in understanding carotenoid biosynthesis led to the development of techniques to separate and quantify these pigments. Capsanthin, the major pigmem in red Capsicum fruits, was isolated by Zeichmeister and Cholnoky (25) in 1927 through extraction with petroleum ether. Carotenoids can be partitioned into pigment classes (hydrocarbons vs. oxygenated xanthophylls) based on differing polarities. This involves phase separations with immiscible solvents and column chromatography. In most cases, thin-layer chromatography (TLC) follows the initial partitioning steps (26).

Carotenoids are unstable when exposed to light, oxygen, or high temperatures. Therefore, careful handling in the laboratory is required to prevent the oxidation and degradation of the pigments. All procedures should be conducted in subdued light and at low temperatures. Some extraction steps should be carried out in a nitrogen atmosphere. Carotenoids are extracted with organic solvents, although no standard method exists. Acetone, ethanol, methanol, and hexane are common extraction solvents. For flesh fruit, ethanol or acetone serves as a dehydration agent and an extraction solvent.

Thin-layer Chromatography

Working with bell peppers, Buckle and Rahman (27) developed a system using column chromatography and thin-layer chromatography to separate and quantify changes in pigments during the ripening of Capsicums. At the time, the method was simple, rapid and inexpensive relative to the previous column chromatography methods

Page 371: Instrumental

354

(26). Cellulose was used as the solid phase on the thin-layer plates, and various solvent systems were tested as the mobile phase. Cellulose was chosen for its neutral properties. Relative to aluminum oxide, magnesium oxide or silica adsorbents, cellulose plates reduce the possibility of pigment isomerization. Pigment extracts of immature and mature green fruit were chromatographed with a light petroleum- acetone-propanol (90:10:0.25, v/v) solvent system. Extracts from partially and fully ripe fruits were chromatographed in a hexane-propanol (99.9:0.1, v/v) mobile phase. TLC bands containing a mixture of pigments were separated on columns containing magnesium oxide-Hyflo Super-Cel (1:1 w/w) and rechromatographed on thin-layer plates. The criteria for the identification of individual pigments were R~ values, band position and color, diagnostic chemical tests, absorption spectra, and cochroma- tography with authentic standards. During the maturation and ripening of bell peppers 26 pigments were separated and identified. Rahman and Buckle (28) followed with a study of five Capsicum cultivars at four stages of maturity.

Thin-layer chromatography of chile carotenoids has been described and used successfully by several authors (26-30). However, TLC is a time-consuming method and often requires further chromatography of unseparated fractions. Problems with reproducibility, accurate quantification, and isomerization of the pigments are likely. Although HPLC has replaced TLC for the separation and quantification of carotenoids, TLC remains useful as a tool for identifying HPLC peaks.

HigJa Performance (Pressure) Liquid C~omatography Analysis

High performance liquid chromatography (HPLC) is the most effective and accurate tool for the separation and quantification of carotenoids. The earliest report describing HPLC methods for separating paprika carotenoids was in 1982 (31), but many reports of improved methods have been published since then (32-43). Method development and peak identification are easier to achieve with the newer instruments equipped with diode array detectors and accompanying software. Also, the use of microbore columns can decrease run times, reduce solvent use and waste, and improve sensitivity. The quantitative determination of individual carotenoids by HPLC analysis revolves sample preparation, extraction, saponification (optional), HPLC separation, peak identification and quantification.

HPLC methods have been developed for the separation of either saponified or unsaponified pigments. Paprika naturally contains carotenoids esterified with fatty acids, as well as free (tmesterified) carotenoids. Saponification removes the fatty acids, leaving only free pigments. HPLC analysis of saponified extracts separates free pigments and provides information on the types of carotenoids present in a sample. When unsaponified pigments are analyzed, the naturally occurring compounds separated are hypophasic or "free" xanthophylls (zeaxanthin, capsombin, capsanthm, violaxanthin, antheraxanthin), carotenoid monoesters (primarily capsanthin, capsorubin and zeaxanthin monoesters), epiphasic carotenoids (cryptocapsin, cryptoxanthin, 13-

Page 372: Instrumental

355

carotene), and carotenoid diesters (26, 44). The ratios between free and esterified pigments, and between monoester and diester carotenoids, can be determined using HPLC analysis of unsaponified samples (37).

Extraction Methods

Fresh chile samples are typically deseeded and destemmed, cut into small (1 cm) pieces and stored a t -20C under nitrogen until extracted (40). Samples are homogenized in acetone and extracted until all the color has been removed. Extracts are combined and ethyl ether is added. A NaCI solution is added to separate the phases. The pigments are contained in the ether fraction. After treatment with anhydrous sodimn sulfate to remove the water, the volume of the ether fraction is reduced using a rotary evaporator (40). Other methods use methanol with calcium carbonate or magnesium carbonate for extraction of pigments from flesh chiles (1, 45). Samples are extracted 3 times with methanol (allowing 18 to 24 hours between extractions) and once with ethanol. Extracts are combined, diluted with ethanol, washed with water, dried over anhydrous sodium sulfate, and evaporated to reduce the volume.

Samples of dried, ground paprika are extracted with acetone, mechanically shaken for 10-30 minutes and left in the dark at room temperature for 4 to 16 hours (34, 37, 38). Addition of 0.5% BHT to the extracts minimizes oxidation (38). Extraction with chloroform- 2- propanol- acetone (2:1:1 v/v/v) for 20 minutes at room temperature has also been reported (35). An aliquot of the extract (about 5 m0 is evaporated to dryness under nitrogen, redissolved in the HPLC eluent, and passed through a 0.45 ~tm filter into HPLC vials.

Saponification

Saponification of chile extracts converts the carotenol fatty acid esters into hydroxy-carotenoids. The diester carotenoids are especially sensitive to alkaline conditions and undergo hydrolysis quickly (37). Saponification allows for HPLC separation of pigments free from fatty acid groups and a simpler chromatogram than with unsaponified carotenoids. Paprika or oleoresin samples are extracted in ethanol (38), methanol (32) or acetone (40) with 2% BHT. In one method, a 60% aqueous potassium hydroxide (KOH) solution is added and the samples are heated at 60C for 25 minutes in a nitrogen atmosphere (38). Other methods use 20% or 30% methanolic KOH without heating (1, 3 l, 40), and a method using sodimn methoxide has been proposed as slower and less destructive to labile carotenoids than the potassium hydroxide method (37). After saponification, water is added, and the carotenoids are exhaustively extracted and washed with hexane. The hexane fractions are combined, washed with water until flee of alkaline, and dried over anhydrous sodium sulfate (38). Solutions are evaporated to dryness, dissolved in the HPLC injection solvent and passed through a microfilter for analysis (44).

Page 373: Instrumental

356

Equioment and Columns _ _

The basic components of an HPLC system are an injector, a solvent delivery system, a colunm, a detector, an integrator and recorder, or a computer. Guard columns protect the main column during extended use and are usually included. A single pump is required for isocratic methods, whereas a ternary pump is needed when a gradient is imposed. Newer instruments usually have ternary solvent delivery systems. Carotenoids can be detected with a UV-vis variable wavelength detector or a photodiode-array detector. A conventional UV-vis detector monitors elutmg compounds at their maximum wavelength, and is designed to measure the absorbance at a single point in the specmma at one time. The solvent flow must be stopped for spectral scanning (if possible), and the peak can elute faster than the time required for the spectral scan. The diode-array detector is designed to continuously scan the absorbance of eluting compounds over the entire spectrum (or a selected range). The diode-array detector facilitates the detection of compounds with different maximum wavelengths, the identification unknown peaks based on their absorption spectra, the confirmation of a peak's identity, the determination of peak purity, and the quantification of non-separated peaks. The diode-array detector is therefore a powerful tool for carotenoid analysis.

Carotenoids can be separated with either normal or reverse phase chroma- tography, but reverse phase methods are preferred because of lower column equilibrium times and less pigment transformations during analysis (40). Several methods are similar, but no standard method exists. Most methods for separating unsaponified carotenoids include either an isocratic or gradient mobile phase with C~8 reverse-phase columns (Table 1). Some methods have two C~s columns in series (1) or a C~8 and a C8 column in series (37, 38). Columns sizes range from 125 to 250 mm in length with 3.4 to 4.6 mm internal diameters and 5-10 ~tm particle size packings. In C18 columns, porous silica particles form the column's support matrix and octadecyl silane (ODS) fimctional groups are bonded to the matrix. Reverse phase columns separate molecules based on their hydrophobic properties. The more polar molecules elute quickly and very hydrophobic molecules interact strongly with the colmnn and elute at later retention times. In carotenoid analysis of paprika extracts, the "free" carotenoids elute first, followed by the carotenoid monoesters, 13-carotene, and finally the carotenoid diesters (36).

Identification_ and Quantification

Individual carotenoids can be identified by their spectral properties, absorbing principally in the 400-500 nm wavelengths. Most carotenoids exhibit 3 absorption maxima, with 1 major peak and 2 minor peaks. The exact wavelengths of the 3 maxima vary among the carotenoids, and therefore can be used for identification. Spectral properties should be examined in different solvent systems, because a shift in maxima

Page 374: Instrumental

Table 1 Summary of HPLC methods for carotenoid separation in Capsicum using reverse-phase chromatography

Reference Column Solvents Gradient Time Flow Detection (v v v) min ml/m Wavelength

Biacs et al., 1989, 1993

Bureau & Bushway, 1986

Fisher & Kocis, 1987

Gregory et d., 1987

Ittah et d., 1993 Levy et d., 1995

Matus et d., 199 1

Mejiaet d., 1988

Mineuez-Mosauera

Chromsil C,,,10 pm or Nucleosil ODS, 5 pm, 250 x 4.6 mm

Partisil 5 ODS 250 x 4.6 mm

Zorbax C , , 250 x 4 6 mm

Waters Resolve C,, I50 x 3 9 mm

Merck RP-I 8, 5 pm, 250 x 3 4 mm, in series with RP-8, 5 pm, 125 x 3 4 mm

Chromsil C,,, 6 pm. 250 x 4 6 mm (2 in series)

Waters Nova-Pak I50 x 3 9 mm

S herisorb ODS 2, 5 pm, 290 x 4 mm

acetonitrile-2-propanol- water (39:57:4)

acetonitrile-tetrahydrofuran- water (85:12.5:2.5)

A:acetone-water (75:25). B:acetone-methanol (75:25)

methanol-ethyl acetate

A acetonitrile-2-propanol (40 60) B water (1 4%)

A methanol-water (88 12) B methanol C acetone-methanol (50 50)

I acetonitnle-methanol- tetrahydrofuran (58 35 7) I1 acetonitrile- tetrah drofuran-water (85 1 1 5 2 5 )

lsocratic

Isocratic

Linear steps

Linear

B: 14% to 0% in 40 min.

Linear steps

--_

1:acetone-water (75:25). I: Linear 11: tetrahydrofuran-water 11-Isocratic

30-35 1-1.2 438 nm

2 ---

60 I

20 1.8

40 0.8

45 1.5

15 1

17 I : l 5 11.1

470 nm

428,460, 480,510 nm

475 nm

260-540 nm

430, 450,480, 400,340 nm

460 nm

& H&nero-Mehdez, 1993,1994 (52 48) -4

450 nm w cn

Page 375: Instrumental

358

will occur. The degree of spectral shift can be used for identification. Several diagnostic chemical tests are available to identify different carotenoids

by their functional end groups (1, 36, 41). Acid treatment converts those carotenoids with the 5,6-epoxide group (violaxanthin, antheraxanthm, capsanthin-5,6-epoxide, cryptoxanthin-5,6-epoxide) to furanoid oxides, resulting in shifted retention times and absorption maxima. The reduction of the red, highly-conjugated ketones (capsanthin, capsorubin, cryptocapsin, capsanthin-5,6-epoxide) with sodium borohydride produces yellow, unconjugated alcohols and therefore, marked changes in retention times and absorption maxima.

Carotenoids can be identified by their HPLC retention times or the 1~ values and band colors on thin-layer chromatography plates. Cochromatography with authentic standards is necessary for identification and quantification. Standards of a-carotene and 13-carotene are commercially available from Sigma (St. Louis, MO, U.S.), whereas others (lutein, zeaxanthm, cryptoxanthin, capsorubin, capsanthin) can be requested from Hoffman-LaRoche (Nufley, NJ, U.S. and Basel, Switzerland). Standards can also be prepared from natural sources. An internal standard such as 13-apo-8'-carotenal or canthaxanthin should be used to monitor extraction efficiency and for quantitation (44).

Problems Associated with HPLC .Analysis

Although carotenoid analysis has been advanced with the use of HPLC, limitations exist to the current methodology (46). An awareness of the potential problems that may occur during analysis can improve the accuracy and repeatability of the technique. Stereoisomers and degradation products may form during the extraction process, because carotenoids are sensitive to heat, light, and oxygen. These artifacts will be more readily detected with HPLC, and the chromatograms may be misinterpreted. Also, reactions between the carotenoids and the mobile phase and injection solvents are possible, producing artifacts. Carotenoids vary in solubility in different solvents, and this must be considered when selecting chromatography solvents. In most situations, the injection solvent should be identical to the mobile phase to reduce peak distortions. Another problem area is the interaction of metal surfaces (stainless steel fittings, filters, frits, and columns) with the pigments, causing artifacts and irregular peaks during chromatography (46). The use of metal-free columns, peek tubing, and Teflon frits can overcome this problem. Future improvements in HPLC columns, detectors, and computer software are likely. As the technology is refmed, the procedures for carotenoid analysis will be modified for accuracy and efficiency, advancing our understanding of chile carotenoids.

Page 376: Instrumental

359

CHILE PUNGENCY ANALYSIS

The nature of the pungency constituents has been established as a mixture of seven homologous branched-chained alkyl vanillylamides, named capsaicmoids (47). Capsaicin is the most prevalent form, while dihydrocapsaicm is usually the second most prevalent capsaicinoid. The other five compotmds, norcapsaicin, nordihydrocap- saicilL nomordihydrocapsaicin, homocapsaicin, homodihydrocapsaicin, are considered minor capsaicmoids because of their relative low abundance in most natural products. The production of capsaicmoids is restricted to the placenta of the fruit pod. No other plant part produces capsaicmoids. Seeds do not contain capsaicinoids, but because of their close proximity to the placenta, they can acquire some pungency.

Bucholtz (48) was the first to realize that the pungent constituents could be extracted by macerating the pods with organic solvents, and in the following year Braconnot (49) observed that the pungent principles could form salts with alkalis. Braconnot named it capsicm (sic). The primary pungent principle was first isolated in a crystalline state from the crude extract by Thresh (50) who named the compound capsaicin. Experimemation by Micko (51) improved on the isolation technique of Thresh, thereby proving capsaicin to be the pungent principle. Micko also demonstrated that capsaicin possessed hydroxyl and methoxy groups, and he postulated a structural relationship to vanillm. By 1920, Nelson (52) had been able to synthesize capsaicm by reacting synthetic vanillylamme with decenoic acid extracted from natural capsaicm. It was not until 1930 that Spath and Darling (53) were able to completely synthesize capsaicm, without using natural products. In 1955, Crombie et al. (54) demonstrated by an unambiguous synthesis that the configuration of the double bond in the acid unit of natural capsaicm is tram. The structure of capsaicin has been established as N-(4-hydroxy-3-methoxybenzyl)-8-methylnon-trans-6-enamide (55).

Capsaicmoids are biosynthesized from L-phenylalanme and L-valine or L- leucme through vanillylamme and C9 to C~1 branched-chained fatty acids (56, 57). The pathway proposed for the biosynthesis of the vanillylamme moiety of capsaicinoids from L-phenylalanine is as follows: L-phenylalanine, trans-cinnamic acid, trans-p- coumaric acid, trans-caffeic acid, trans-ferulic acid, vanillin, and vanillylamine. The enzymes which catalyze ferulic acid into vanillylamine are not known. Also, capsaicmoid synthetase which catalyzes the condensation of vanillylamme and a C9 to CI~ branched-chain fatty acid has not been purified. Chile powder is a complex mixture of these closely related amides. The term "capsaicinoids" is used to represent these homologues and analogues of capsaicin.

While the capsaicmoids may be devoid of"flavor" and odor, they are some of the most pungem compounds known, producing a detectable heat in the mouth at concentrations as low as 10 ppm. Beside food uses, medicinal applications of chile pungency has brought renewed interest to the capsaicinoids. Chile pungency has long been associated with medicinal properties. The Aztecs of Mexico have used chile pungency to relieve pain, e.g. toothaches. Moreover, accurate determination of the

Page 377: Instrumental

360

level of various capsaicmoids also is needed due to their increase use in the pharmaceutical industry (58). The muscle liniments "Sloan's Liniment" and "HEET" have capsaicin as an active ingredient. It was a pharmacist, Wilbur Scoville, at Park- Davis, the company producing "Heet", that developed the first heat measuring test for chiles (59).

Medicinally, capsaicm is being used to alleviate pain. Its mode of action is thought to be from nerve endings releasing a neurotransmitter called substance P. Substance P informs the brain that something painful is occurring. Capsaicm causes an increase in the amount of substance P released. Eventually, the substance P is depleted and further releases from the nerve endings are reduced. Cream containing capsaicin is used to reduce the pare associated with post-operative pare for mastectomy patients and for amputees suffering from phantom limb pain. Prolonged use of the cream has also been found to help reduce the itching of dialysis patients, the pare from shingles (Herpes zoster), and cluster headaches. Further research has indicated that capsaicin cream will reduce the pain associated with arthritis. The repeated use of the cream apparently counters the production of substance P in the joint, hence less pain. A decrease in substance P also helps to reduce long-term inflammation. Inflammation can cause cartilage break down.

Accurate measurement of pungency has become important because of the increased demand for pungent foods. Food industry researchers need reliable, safe, and standard analytical procedures that are useful for comparing pungency among products, and to produce a product with a known and consistent pungency level. The capsaicmoid content varies among cultivars of the same species and among the fruit of a single cultivar (60). The pungency of a given cultivar varies with growing location. More specifically, any stress to the plant will increase the amount of capsaicinoids in the pod. The pungency level of Capsicum has genetic and environmental components (60). If the same cultivar was grown in both a hot semi-arid region and in a cool coastal region, the fruit harvested from the hot semi-arid region would be higher in capsaicmoids than the fruits harvested in the cool coastal climate. The capsaicinoid content is affected by the genetic make-up of the cultivar, weather conditions, growing conditions, and fruit age. Plant breeders can selectively develop cultivars with varying degrees of pungency. Also, growers can somewhat control pungency by the amount of stress to which they subject their plants. Capsicum is hottest after it has survived a more stressful growing environment. This can be too little or too much water, high or low temperatures, low soil fertility; any factor that is stressful to the plant. A few hot days can increase the capsaicmoid content significantly. In New Mexico, it has been observed that even after a ~ o w imgation, the heat level will increase in the pods. The plant has sensed the flooding of its root zone as a stress, and has increased the capsaicmoid level in its pods.

Page 378: Instrumental

361

Measuring Chile Capsaicinoids

Kosuge et al. (61) showed that extracts of Capsicum and the crystalline "capsaicin" from the fruit contained capsaicin and dihydrocapsaicin and proposed the term capsaicinoids for the mixture of pungency stimuli in the fruit. Many papers on the determination of the total pungency principles continue the use of the term capsaicin or natural capsaicin. In this review, the term capsaicinoids is used for the total mixture, and the individual components are given specific names. Analytical methods are needed to measure pungency routinely, because chile pungency is variable from lot to lot. The estimation of the capsaicmoids needs to be reproducible and accurate when determining pungency. There are more that 200 papers published on the determination and estimation of the capsaicinoids in Capsicum, the oleoresin, and products containing their extracts. The methods could be grouped into:

1) organoleptic 2) colorimetric methods: chromogenic reagents reacted directly with the

phenolic hydroxyl of the vanillyl moiety on the extracts of the fruits 3) thin-layer chromatography (TLC) and paper chromatography 4) gas chromatography 5) high-performance liquid chromatography

There are many modifications to each group listed above. A representative sampling of the methods will be discussed.

Org .anoleptic Method

The first reported reliable measurement of chile pungency is the Scoville Organoleptic Test (59). The organoleptic method or taste test has been the standard method for pungency analysis in the food industry. This test uses a taste panel of five individuals that validate a chile sample and then record the pungency level. A sample is then diluted until pungency can no longer be detected orally. The dilution is referred to as the Scoville Heat Unit. Historically, this has been the most important and the only sensory method for the assessment of heat in chile. While the Scoville Organoleptic Test originally filled the need for a means of measuring and expressing heat in chile products, it has been criticized for its lack of accuracy and precision (62-64). Specific problems noted with the Scoville Organoleptic Test are build-up of pungency, rapid taste fatigue and increased taste threshold as a result of the 5 samples required for tasting, ethanol bite interfering with the pungency, poor precision, and more importantly, the taste panel cannot determine the amount of the individual capsaicinoids present in the sample.

Gillette et al. (62) developed a replacement method for the Scoville Organoleptic Test for chile powder. They took 5 grams of ground chile powder, steeped it for 20 minutes in 1995 ml of 90C water, filtered it, and then took 20 ml of the filtrate and diluted it into 180 ml of 20C water. Trained testers compared this

Page 379: Instrumental

362

concoction to a standard concentration of synthetic capsaicm. Because most testing laboratories were using the HPLC method, there had to be a validation of the msmmaental methods with the new sensory method.

To evaluate the correlation of sensory responses with HPLC capsaicmoid quantitation, Gillette et al. (62) took samples from 60 lots of ground chile to represent the normal range of Scoville Heat Units found in red chile powder. These 60 samples were analyzed msmunentally for the 3 capsaicinoid analogs (nordihydrocapsaicin, capsaicin, and dihydrocapsaicin) and sensorially by the Scoville Organoleptic Test. The samples were also assessed using their new sensory method for pungency ratings. All possible single and multiple regressions were performed in order to determine the optimal instrumental altemative for the new sensory method, as well as to further substantiate the precision of the new sensory method. Several very strong relationships (r-0.90) were found between the instrumental and sensory measurements. They concluded that the HPLC method and the new sensory method can provide accurate measurements of pungency and can be converted to Scoville Heat Units that are universally understood.

Colorimetric Methods

A number of colorimetric and ultraviolet spectrophotometric procedures have been reported for the determination of capsaicin. A comprehensive review of these techniques has been published in the first (65) and second (66) report of the Joint Committee of the Pharmaceutical Society. It was found that these procedures do not differentiate between capsaicin and its synthetic analogs and, therefore, have limited utility.

Historically, an early colorimetric method was developed using vanadium oxy- trichloride or ammonium vanadate and hydrochloric acid to react with the phenolic hydroxyl group of the vanillylarnides. A resulting blue color was measured. The variable natural color of the extracts proved to be a source of variability in the color matching method. The different fruit colors; i.e. orange, light red, dark red, etc. gave dissimilar readings for the same amount of capsaicinoids. Attempts were made to compensate for this natural color by use of natural carotenoid, mixtures of synthetic color, and mixtures of the inorganic salts (cupric nitrate and potassium chromate), all adjusted to the color of the sample. This was tedious because the color of the different fruit samples varied with cultivars, harvest maturity, drying conditions, and storage.

North (67) obtained the separation of capsaicinoids from pigments in the extract by repeated partition between alkaline polar and nonpolar solvents. The capsaicinoids with only a trace of color and fat were estimated by reacting with phenolic reagents, e.g. phosphomolybdic and phosphotungstic acid. Pure vanillin, then more readily available than capsaicinoids, was used for the standard curve, and the value obtained from reference to the standard curve was multiplied by a factor of two, based on the relation of the molecular weights to vanillin and capsaicin. This method was a major

Page 380: Instrumental

363

advance in minimizing the interference from pigments and fat. However, the number of steps in the clean-up made the method time consuming, and recovery and reproduc- ibility were often reported to be poor.

Kosuge and Inagaki (61) determined capsaicmoids in ether-extracted concentrates, taken in carbon tetrachloride, washed with acetic acid, and reacted with Folm-Ciocaltew reagent. The blue color was measured at 750 nm and quantified using pure vanillin as a standard and a conversion factor of 2.15 to give capsaicmoids. They analyzed many samples by this method in their study of cultivars, effect of maturity, cultivation practices, etc. but details of sensitivity, reproducibility, and repeatability are not available. The vanadium oxytrichloride reagent had problems of stability both with the reagent and the blue color formed.

Today, the colorimetric method is limited to plant breeding programs where a direct, rapid method for detecting the presence or absence of capsaicinoids in cultivars requiring no pungency, i.e. paprika, bell peppers, pimento, etc. is needed. The vesicles along the placenta containing possible capsaicmoids are challenged with a 1 percent solution of vanadium oxytrichloride in carbon tetrachloride. If there is a color reaction (green) capsaicinoids are present (68).

Separation and Quantification of Capsaicinoids

With the rapid advancement of analytical instrumentation, many methods were developed to overcome the traditional sensory method and the difficult colorimetric methods. Newer separation methods emerged including paper chromatography, thin- layer chromatography, gas chromatography, GC-mass spectrometry, and high performance liquid chromatography to objectively determine capsaicinoids. These gave rapid and more efficient separations of complex mixtures of natural compounds, and at the same time were simple and offered great operational flexibility. They were quickly used in the determination of total, and later individual, capsaicmoids.

Thin-layer Chromato~aphy

One of these methods was thin-layer chromatography (TLC). The first report of the separation of capsaicmoids from other substances in a capsicum extract was made by Tiechert et al. (69). Dohmann (70) developed the separation into a quantitative method that appears simple and clear for routine assay of total capsaicmoids. Chloroform extracts of the powdered chile were applied on silica gel-G plates along with standard capsaicmoids solutions equivalent to 100, 150, and 200 ug. The plate was developed with chloroform-methanol-acetic acid to a distance of 14 cm. The bands were marked as dark areas under ultraviolet light. The capsaicinoids near the solvent front were clearly separated from the pigments near the starting line. The separated bands of the capsaicinoids from the sample and standards were scraped off carefully into individual tubes and reacted with Folm-Denis reagent. The blue color formed was

Page 381: Instrumental

364

cleared by centrifugation and measured at 725 nm. The total capsaicinoids in the sample was calculated by reference to the standard curve of absorption vs. micrograms of crystalline capsaicinoids run on the same plate and the dilutions in making the extracts.

Most of the methods used silica gel plates, but with many variations in the developing solvents from single solvents, e.g. dimethyl ether, to mixed solvents of varying polarity, with varying clarity of separation of the pigments and capsaicinoids. However, one of the TLC methods where the different optimization steps have been studied and found to be satisfactorily simple, rapid, and reproducible was detailed by Jentzsch et al. (71). From a review of earlier methods, TLC on silica gel for separation and Gibbs' dichoroqumonechlorimide reagent for greater specificity and sensitivity was chosen, and the color reaction was optimized. Pankar and Magar (72) used the Gibb's reagent (2,6-dichloro-p-benzoqumone chloramme) along with multi-band thin-layer chromatography to estimate capsaicin quantity. They claim that their method required no preliminary purification of chile extract; was less tedious, and more rapid and accurate.

TLC as a quantitative method has not been found to be very satisfactory m repeatability. It requires skill in making the plates, spotting of quantitatively microliter amounts of samples, and collection of separated component areas quantitatively for colorimetry. Permanently coated plates and automated densitometers are now available to improve performance, but are costly.

Paper chromatography for the separation of capsaicinoids can also be accomplished. However, the higher resolution capability of TLC techniques is more useful in separation of individual capsaicinoids. Salzer (73) has stated that for routine analysis the paper chromatography method is acceptable. The method was recommended for routine use when the composition is natural and no synthetic compound has been added. This simple, sensitive, and reproducible method is one of the two recommended methods for capsaicinoids measurements by the Indian Standards Institution for oleoresin capsicum.

Gas Chro _mato~raohv v _ _

Gas chromatography is a more sophisticated approach to analyzing capsaicinoids. This separation method requires a higher level of insmunentation, skill in operation, and preparative work on extracts. However, this method is rapid and sensitive for the analysis of microgram quantifies. This method has been used to detect adulteration of capsaicinoids with synthetic vanillylamides. The higher resolving power and the discovery of the volatility of the silyl derivatives of poorly volatile and nonvolatile compounds have subsequently been used in the direct quantitation of individual capsaicmoids. The rapidity of analysis was attractive to developing methods for total capsaicinoids and for laboratories that used this equipment routinely for other analyses. Morrison (74) showed that a benzene solution of capsaicinoids injected into

Page 382: Instrumental

365

a GC gave a clear, dominate peak, indicating the possibility of direct chromatography of capsaicmoids. Hollo et al. (75) by similar direct GC of crystalline capsaicmoids on a mixed glycol esters column on silianized glass powder at a lower temperature obtained a major and a minor peak. These peaks were quantified by their peak areas with reference to cholesterol as the internal standard. The capsaicmoids value by the major peak was only 91 to 93% of the value obtained by TLC methods. The difference was accounted for by the area of the minor peak, that was considered a minor analog. Similar results were also obtained by direct analysis of paprika extracts. Tailing of peaks and degeneration of columns and consequent problems of poor reproducibility lead to common use of the GC separations of the more volatile and stable silyl derivatives. The sensitivity and accuracy were improved by the use of an alkali flame detector that had 25 times the response of the flame ionization detector.

Jurenitsch et al. (76) analyzed the capsaicmoids composition of fruits from different Capsicum species and cultivars using a combination of TLC and GC. Using extracts from lg of sample, they separated the capsaicinoids by rapid TLC, developing with ether, free from color and fat. The capsaicinoids were extracted with methanol- water (95 + 5, v/v). Under carefully controlled GC separation conditions, the sequence of elution with TLC-purified capsaicmoids mixture showed noncapsaicmoids, the internal standard, an unknown noncapsaicinoid peak, octonoyl vanillylamide, nordihydrocapsaicm, capsaicm, dihydrocapsaicin as partially resolved peaks, and homodihydrocapsaicm.

Mueller-Stock et al. (77) purified the capsaicinoids from fruits by a 70% acetic acid treatment. The components were identified by a combined mass spectrometer and quantitated by an automatic area integrator of the peaks. There was clear separation of a minor peak of nordihydrocapsaicin, a dominant capsaicm, and an overlapping but distinct peak of dihydrocapsaicm. The higher homologs, homocapsaicm and homodihydrocapsaicin, usually in minor amounts, were not separated. Todd et al. (63) used programmed temperature GC conditions for distinct separation of five branched- chain homologs and three straight-chain analogs of capsaicin in a comprehensive study of the different analytical steps. They described a defmitive method to quantify these components that correlated highly with the organoleptic test. These GC methods require considerable preparative work for isolation and derivatization and operative skill in separation. Masada et al. (78) found that a 3% SE-30 column is optimal for the gas chromatographic separation of the capsaicinoids.

Lee et al. (79) developed a mass fragmentographic method in concert with gas- liquid chromatography for the quantitative microanalysis of capsaicm, dihydro- capsaicm, and nordihydrocapsaicin. The molecular ions at m/e 377, 379, and 365 in mass spectra were used for monitoring the trimethylsilyl derivatives of capsaicm, dihydrocapsaicm, and nordihydrocapsaicm, respectively. The ratios of the height of each molecular ion to that of an internal standard (cholestane) were linear over the range 5-60 nanograms. This was the first work to determine capsaicin, dihydro- capsaicin, and nordihydrocapsaicm at the nanogram level in chile powder.

Page 383: Instrumental

366

Gas chromatographic methods usually require derivatization in order to convert the analytes to more volatile compounds before analysis. Because capsaicmoids cannot be determined using gas-liquid chromatography without derivatization, several HPLC methods have been developed that are based on underivatized direct injections.

High Performance (Pressure) Liquid Chromatography Analysis

With the emergence of high performance liquid chromatography (HPLC) techniques, the GC methods were replaced with HPLC analytical methods. Techniques using HPLC, known earlier as high pressure liquid chromatography, have superior separation capabilities. It provides accurate and efficient analysis of content and type of capsaicmoids present in a chile sample (80). The separation is also generally effected directly on the extracts of the natural materials without any preliminary clean- up. This high performance separation method found ready application in the separation of closely related compounds, e.g., the homologs and analogs of capsaicm With the availability of ready-made columns, automated high-pressure pmnps, optical detection devices (ultraviolet and fluorescence), and recording and integrating accessories, HPLC analysis has become the standard method for routine analysis by the processing industry. The method, being rapid, can handle a larger number of samples and, with the sensitivity of the detection systems, can be worked at submicrogram levels. With less separation efficiency, the technique is also used on a preparative scale. Besides the advantages of rapid direct analysis of natural extracts chile products, HPLC has superior separation capabilities for closely related compounds and is operated at room temperature. Combined with additional operational parameters, e.g., reversed-phase systems, silver-ion complexing of olefmic compounds, and optical detectors, the separation efficiency, sensitivity, and quantification at submicrogram levels of capsaicmoids have been demonstrated in recent years. HPLC analysis accurately determines the homologs and analogs of capsaicin and, combined with mass spectral analysis, can identify the structural isomers of the minor components. Nanogram levels of the individual capsaicmoids, as is required in biosynthetic and metabolic studies, can be determined using HPLC.

Lee et al. (79) reported separation by HPLC of capsaicin and dihydrocapsaicm from commercial capsaicmoids on a reversed-phase column by gradient elution, increasing the methyl alcohol in water. The separation was effected in 20 min and easily monitored by UV absorption at 254 nm. Woodbury (81) developed a HPLC method that allowed analysis of as many as 50 samples a day that varied from less than 300 ppm to 13,000 ppm in capsaicmoids. This was possible by the combination of the efficient separation and spectroflurometric measurement that was more sensitive and selective even at low levels of capsaicmoids. Woodbury used HPLC for the estimation of capsaicmoids and correlated the Scoville Heat Units (SHU) based on the ppm numbers with the Scoville Heat Units determined by the organoleptic test. The common practice, today, is to multiple ppm by 15 to convert to SHU.

Page 384: Instrumental

367

Woodbury's HPLC method is the foundation for all subsequent modifications to the HPLC method. His method entails extracting chile powder at 60C for 5 hours using 95% ethanol saturated with sodium acetate. Separation was effected by injection of the sample onto a LiChrosorb RP-18 (10#m) column (250 X 4.6 mm i.d.). Capsaicmoids were eluted with water-acetonitrile-dioxane-2M perchloric acid as the primary eluent and methanol-dioxane-acetonitrile as the secondary eluent used either isocratically or with a gradient elution. Detection was by monitoring fluorescence emission at 320 nm, with excitation at 288 nm.

Jurenitsch et al. (82) accomplished clear separation of the capsaicm homologs and analogs directly from ground fruit extracts in about 70 mm by HPLC on a reversed-phase system, eluted with dioxane-water. Four samples of Capsicum fruits containing a range of 0.2 to 1% of total capsaicmoids were analyzed by this HPLC method and also by the TMS-GC method. There was fairly close agreement between the methods for total capsaicinoids. The HPLC method was clearly superior.

Chiang (83) developed a highly sensitive HPLC method with electrochemical and UV detection to separate and quantify the capsaicinoids. Capsaicmoids are highly electroactive compotmds. Their electroactivity was believed to be due to the easily oxidized phenolic functional group. The electrochemical detection of capsaicinoids provided a high degree of sensitivity and specificity. Non- and less electroactive interfering compounds were eliminated. Thus it allowed sample analysis to be shortened to 30 minutes, including sample preparation. She was able to detect to a level of 0.06 ppm. When she combined it with UV detection, she was able to simultaneously determine capsaicmoids and piperine ( the pungent compound in black pepper, Piper nigrum) in a mixture.

Games et al. (84) used a combination of HPLC-mass spectrometry with a moving-belt interface, field desorption mass spectrometry, and high-resolution accurate mass electron impact mass spectrometry to identify the capsaicinoids in oleoresins. Field desorption is a soft ionization technique that directly examines a complex mixture without prior separation. They concluded that HPLC-mass spectrometry using a moving-belt interface is well suited for the identification of compounds present in oleoresms, especially when high-resolution accurate mass data are also available. They stated that a clear advantage of the moving-belt interface is the ability to obtain electron impact spectra that can be directly compared with existing electron impact libraries. The field desorption-mass spectrometry technique complemented HPLC-mass spectrometry, because it produced a total profile of the sample to be obtained. Therefore, if components had degraded or were lost during HPLC- mass spectrometry this would be evident.

A high performance liquid chromatography-chemilummescent nitrogen detector (HPLC-CLND) was used to quantitatively analyze for capsaicin and dihydrocapsaicin in chile (85). The principle is that non-nitrogenous compounds in the sample matrix are transparent to the detector. Quantitative analysis of capsaicin and dihydrocapsaicin in chile extract was demonstrated. Thus, it was reported that utilization of this technique

Page 385: Instrumental

368

allows one to "see" through the non-nitrogenous components in the sample in order to simplify the detection, identification, and quantiation of nitrogen containing analytes. This method is so recent that there has not been an opporttmity for the capsicum industry to test its usefulness.

Analysis for capsaicmoids by reversed-phase HPLC is recommended and has become the standard method in the processing industry. Table 2 is a comparison of the most common HPLC methods referenced in the literature. The method of Collins et al. (80) has the shortest analysis time, increased sensitivity, and safety. All the HPLC methods require a dry powder for extraction of the capsaicmoids.

Because most HPLC methods require a dry ground powder for analysis, a quick assessment of fresh ripe chiles would be useful in determining pungency value before the product is brought to the processing plant for handling. This is intended to replace trained buyers tasting the raw fruit in the field and relying on their sensitivity and pungency response memory to make purchase decisions.

A unique solvent rejection-extraction procedure that allows direct measurement of relative capsaicmoids content of flesh jalapefio chiles has been described by Rymal et al. (86). In the method proposed, the cross walls of the pod are ruptured without puncamng the pod wall by rotating a hypodermic needle inserted from the stem end from opposite sides. The pod is then filled with absolute methanol through one of the holes made using the needle and syringe and allowed to stand for 30 mm. The extract is flushed with three 10-mQ portions of methanol and extract made up to a volume of 50 mQ, and absorbance is measured at the absorption maxima, 275 nm. This method depends on extracting single whole pods, thus representative sampling could be a problem, especially when the fruits in a plant are of varying maturities. At New Mexico State University, another method is being tested where the flesh fruit is ground in a blender and the capsaicmoids extracted with methanol. The solution is then filtered and injected into the HPLC. The value difference between the "wet" product and the standard dry ground product should be attributed to the water amount in the flesh product. Preliminary tests indicate this to be true.

Methods for estimating capsaicmoid levels in blood, tissues and waste fluids have been developed. One such use of the capsaicmoids is to monitor dietary intake in controlled food studies or where designer foods are being feed. Saria et al. (87) described a method for separation and determination of nanogram levels of capsaicin and analogs in blood and deproteinized extracts of animal tissues, necessary in pharmacological studies of capsaicin. They used a reversed-phase C~8 column and elution with isocratic methanol-water (40 to 60 v/v) for separation. In the place of the UV absorption at 280 nm, they used a more sensitive fluorometric detector set for excitation at 270 nm and emission at 330 nm with the detection limits at 3 ng and linearity range of 3 to 5000 ng. Johnson et al. (88) developed procedures for the determination of trace amounts of capsaicmoids, as low as 500 ppb in feed and 10 ppb in urine and waste water, required in toxicological studies.

Page 386: Instrumental

Table 2. Comparison of HPLC methods for capsaicinoid detection. Protocol Extraction Flow rate Fluorescence detector rnm) bear) method Cleanup Mobile phase (mlmin-') Excitation Emission

ASTA (1 985) Sodium-acetate-saturated Allow solids Acetonitrile, dioxane, 0.6-1.8 288 320 95% ethanol, 3-h hot plate or water bath

to settle perchloric acid, water methanol

95% ethanol, 5-h refluxing

Acetonitrile, water,

purge used acetic acid, column

1.5 280 325 ASTA (1993) 0.45-pm syringe filter

Attuquayefio and Buckle

( I 987) Acetonitrile Sep-pak filtration Methanol, water 3.5 NIA

1 .o 280

NIA

338 Collins et al.

(1995) Acetonitrile, 4-h water bath

0.45-pm syringe filter

Methanol. water

Copper et al. (1991) Method 1: methanol and

Method 2: silica gel, NIA

0.45-pm filter centrifugation

hexane, methanol, water bath

Methanol, water,

Methanol, water, citric acid

citric acid

1.5 229

1.5 229

320

320

Hoffman et al. (1983) 95% ethanol, Allow solids

5-h heating to settle Acetonitrile, water 1.5 NIA NIA

Woodbury (1 980) Sodium-acetate-saturated Allow solids

95% ethanol. to settle Acetonitrile, water 1 .o 228 320

dioxane. methanol. W Q, 5-h hot plate perchloric acid . \o

Page 387: Instrumental

370

CONCLUSION

Chile is an internationally traded commodity. Because most chiles are used in food preparations, the quality of the product is important. Color, together with pungency, is used to assess the quality and value of chile and determines the price of the product in the international market arena. Analytical methods allow standard specifications to be set by the industry and provide a means to verify whether purchased ingredients meet contract specifications. This removes uncertainty for the chile processors, food manufacturers, and consumers regarding the carotenoid content of chile products. The method of the American Spice Trade Association provides a measurement of total pigment content, and is widely used by the spice industry for color analysis. However, HPLC is the most accurate method for quantifying individual carotenoids and for evaluating whether synthetic colorants have been added to a product. As the HPLC technology is refined, the procedures for carotenoid analysis will be modified for accuracy and efficiency, advancing routine analysis of individual carotenoids by the food industry.

The pungency of chiles can be mimicked by the amides of vanillylamine and fatty acids. These amides are made easily and cheaply, and unfortunately, offer attractive adulterants for chile powders. Synthetic amides may have toxic properties, and they do not have the same pungency as capsaicin, giving poor correlations between chemical and organoleptic procedures. Thus, analytical methods allow for their detection and assist in guaranteeing a safe and uniform product. When the analytical methods are reviewed, it is apparent the benefits of high performance liquid chromatography make it the first choice. Colorimetry, spectrometry, paper chromatography, and thin-layer chromatography methods either lack specificity or are not suitable for quantitation purposes. Gas chromatographic methods are inferior to high performance liquid chromatography methods because derivatization prior to analysis is necessary.

At the same time, it must be recognized that the method chosen for analyzing chile products is dependent on the operational cost. Currently, HPLC is the best method for analyzing carotenoids and capsaicinoids. However, the cost of the equipment and of the trained personnel may warrant a less expensive method of analysis. In the final judgement of a product, it is important to remember that the analytical method chosen must correlate with the consumer's perception of the product, whether visual, olfactory, or organoleptic.

REFERENCES

1 Matus Z, Deli J, Szabolcs J. J Agric Food Chem 1991; 39:1907-1914. 2 Poppel VG. Eur J Cancer 1993; 29:1335-1344. 3 Silver WL, Maruniake JA. Chem Senses 1982; 6:295-305. 4 Voss D. HortScience 1992; 27(12):1256-1260.

Page 388: Instrumental

371

5 Commission Intemationale de rEclairage (CIE). Supplement 2, CIE Publ 15 (E- l.3.1) Paris:Bureau Centrale CIE, 1978.

6 McGuire R. Hortscience 1992; 27(12):1254-1255. 7 Govindarajan VS. CRC Crit Rev Food Sci Nutr 1988; 25(3): 185-282. 8 Essential Oil Assoc (EOA). Specification for oleoresm paprika, EOA No. 239.

New York: EOA, 1975. 9 Assoc Off Anal Chem (AOAC). Official Methods Analysis. Virginia: AOAC,

1984. 10 Woodbury JE. J Assoc Off Anal Chem 1977; 60:1-4. 11 Amer Spice Trade Assoc (ASTA). Official Analytical Methods. New Jersey:

ASTA, 1985. 12 Baranyai M, Szabolcs J. Acta Alimentaria 1976; 5:87. 13 Bartley G, Scolnik P. Plant Cell 1995; 7:1027-1038. 14 Davies BH, K/3st H, In: K/3st H, Zweig G, Sherma J, eds. CRC Handbook of

Chromatography, Plant Pigments, vol 1. Florida: CRC Press, 1988; 3-8. 15 Goodwm TW. In: The Biochemistry of Carotenoids, Plants, vol 1. London:

Chapman and Hall, 1980. 16 Goodwin TW, Britton G. In: Goodwin TW, ed. Plant Pigments. London: Academic

Press, 1988; 62-132. 17 Dogbo O, Camara B. Biochem Biophys Acta 1987; 920:140-148. 18 Kuntz M, R0mer S, Suire C, Hugueney P, et al. Plant J 1992; 2:25-34. 19 Camara B. Pure Appl Chem 1985; 57:675-677. 20 Dogbo O, Laferriere A, d'Harlmgue A, Camara B. Proc Natl Acad Sci 1988;

85:7054-7058. 21 Hugueney P, R6mer S, Kuntz M, Camara B. Eur J Biochem 1992; 209:399-407. 22 Camara B, Dogbo O, d'Harlmgue A, Bardat F. Phytochem 1985; 24(11):2751-2752 23 Camara B, Moneger R. Dev Plant Biol 1980; 6:363-367. 24 Bouvier F, Hugueney P, d'Harlmgue A, Kuntz M, Camara B. Plant J 1994; 6:45-

54. 25 Zeichmeister L, Cholnoky L. Ann Chem 1927; 454:54. 26 Camara B, Moneger R. Phytochem 1978; 17:91-93. 27 Buckle K, Rahman F. J Chrom 1979; 171:385-391. 28 Rahman F, Buckle K. J Food Tech 1980; 15:241-249. 29 Candela M, Lopez M, Sabater F. Biol Plantarum 1984; 26(6):410-414. 30 Vinkler M, Richter K. Acta Aliment 1972; 1:41-58. 31 Baranyai M, Matus Z, Szabolcs J. Acta Aliment 1982; 11:309. 32 Almela L, Lopez-Roca J, Candela M, Alcazar M. J Chrom 1990; 502:95-106. 33 Almela L, Lopez-Roca J, Candela M, Alcazar M. J Agric Food Chem 1991;

39:1606-1609. 34 Biacs P, Daood H, Pavisa A, Hajdu F. J Agric Food Chem 1989; 37(2):350-353. 35 Biacs P, Daood H, Huszka T, Biacs P. J Agric Food Chem 1993; 41:1864-1867. 36 Fisher C, Kocis J. J Agric Food Chem 1987; 35:55-57.

Page 389: Instrumental

372

37 Ittah Y, Kanner J, Granit R. J Agric Food Chem 1993; 41:899-901. 38 Levy A, Harel S, Palevitch D, Akiri B, et al. J Agric Food Chem 1995; 43:362-

366. 39 Mejia L, Hudson E, Gonzalez de Mejia E, Vazquez F. J Food Sci 1988;

53(5):1448-1451. 40 Minguez-Mosquera M, Hornero-Mendez D. J Agric Food Chem 1993; 41:1616-

1620. 41 Minguez-Mosquera M, Jaren-Galan M, Garrido-Fernandez J. J Agric Food Chem

1993; 41:2120-2124. 42 Minguez-Mosquera M, Hornero-Mendez D. J Agric Food Chem 1994; 42:38-44. 43 Minguez-Mosquera M, Jaren-Galan M, Garrido-Fernandez J. J Agric Food Chem

1994; 42:645-648. 44 Khachik F, Beecher G, Goli M, Lusby W. Meth Enzy 1992; 213:347-359. 45 Gregory G, Chen T, Philip T. J Food Sci 1987; 52(4):1071-1073. 46 Scott K. Food Chem 1992; 45:357-364. 47 Hoffman PG, Lego MC, Galetto WG. J Agric Food Chem 1983; 31:1326-1330. 48 Bucholtz PA. Almanach Taschenbuch Scheidekunstler Apotheker Weimar 1816;

37:1. 49 Braconnot, A. Ann Chim Phys 1817; 6:122. 50 Thresh JC. Pharm J 1846; 6:941. 51 Micko L. Z Unters Nahr Genussm Gebrauchsgegentaende 1898; 1:818. 52 Nelson EK. J Amer Chem Soc 1920; 42:597-599. 53 Spath E, Darling S. Chem Abstr 1930; 24:3504. 54 Crombie L, Dandegaonker SH, Simpson KB. J Chem Soc 1955; 1025-1027. 55 Nelson EK, Dawson LE. J Amer Chem Soc 1923; 45:2179-2181. 56 Bennett DJ, Kirby GW. J Chem Soc 1968; 442-446. 57 Leete E, Louden M. J Amer Chem Soc 1968; 90:6837-6841. 58 Carmichael JK. Amer Family Physician 1991; 44:203-210. 59 Scoville WL. J Amer Pharm Assn 1912; 1:453. 60 Lindsey K, Bosland PW. Capsicum & Eggplant Newsletter 1995; 14:36-38. 61 Kosuge S, Inagaki Y. Nippon Nagei Kagakui Kaishi 1959; 33:470. 62 Gillette MH, Appel CE, Lego MC. J Food Sci 1984; 49:1028-1033. 63 Todd PH, Bensinger MG, Biftu T. J Food Sci 1977; 42:660-665,680. 64 Suzuki JI, Tausig F, Morse RE. Food Tech 1957; 11:100-104. 65 Anonymous. Joint Committee Pharm Soc 1959; Analyst 84:603. 66 Anonymous. Joint Committee Pharm Soc 1964; Analyst 89:377-388. 67 North H. Anal Chem 1949; 21:934-936. 68 Ting SV, Barrons KC. Proc Amer Soc Hort Sci 1942; 40:504-508. 69 Tiechert K, Mutscher B, Rochelmeyer H. Z Anal Chem 1961; 181,325. 70 Dohman K. Lab Pract 1965; 14:808. 71 Jentzsch K, Kubelka W, Pock H. Sci Pharm 1969; 37:153-162. 72 Pankar D, Magar N. J Chrom 1977; 144, 149.

Page 390: Instrumental

373

73 Salzer UJ. CRC Critical Rev Food Sci Nutr 1977; 345-373. 74 Morrison JI. Chem Ind 1967; 42:1785-1786. 75 Hollo J, Kurucz E, Dodor J. Lebensm Wiss Technol 1969; 2:19-21. 76 Jurenitsch J, Kubelka W, Jentzsch K. Sci Pharm 1978; 46:307. 77 Mueller-Stock A, Joshi RK, Buchi J. Pharm Acta Hev 1973; 48:504-516. 78 Masada Y, Hashimoto K, Inoue T, Suztd~ M. J Food Sci 1971; 36:858-860. 79 Lee KR, Suzuki T, Kobashi M, Hasegawa K, Iwai K. J Chrom 1976; 123:119-128. 80 Collins MD, Wasmund LM, Bosland PW. HortScience 1995; 30(1):137-139. 81 Woodbury JE. J Assoc OffAnal Chem 1980; 63:556-558. 82 Jurenitsch J, Bingler E, Becker H, Kubelka W. Plant Med 1979; 36:54. 83 Chiang GH. J Food Sci 1986; 51:499-503. 84 Games DE, Alcock NJ, Greef J, Nussen LM, et al. J Chrom 1984; 294:269-279. 85 Fujinari EM. In: Charalambous G, ed. Dev Food Sci: Spices, Herbs and Edible

Fungi, New York: Elsevier 1994; 367-379. 86 Rymal KS, Cosper RD, Smith DA. J Assoc Off Anal Chem 1984; 67:658-659. 87 Saria A, Lembeck F, Skofitsch G. J Chrom 1981; 208:41-43. 88 Johnson K, Thompson HC, Bowman MC. J Agric Food Chem 1982; 30:324.

Page 391: Instrumental

This Page Intentionally Left Blank

Page 392: Instrumental

375

Chemiluminescent Nitrogen Detectors (CLND) for GC, SimDis, SFC, HPLC and SEC Applications

In memory of Dr. George Charalambous (Editor), to whom this manuscript was originally promised. A large portion of this chapter is related to Food/Flavor applications. The CLND techniques however, reach far beyond these boundaries in chromatographic detection.

With the help of friends and colleagues, we will show the use of nitrogen-specific detection for chromatographing compounds as small as acetonitrile (Mw - 41 dalton) by GC to a macro- molecule as large as poly(acrylamide) (Mw = 6,000,000 dalton) by SEC. The CLND is also a valuable tool for SimDis, SFC and HPLC.

Eugene M. Fujinari, Ph.D. Applied Research Chemist

Page 393: Instrumental

376

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved

Chemiluminescent Nitrogen Detectors (CLND) for GC, SimDis, SFC, HPLC and SEC Applications

Eugene M. Fujinari

Antek Instruments Inc., 300 Bammel Wesffield Road, Houston, Texas 77090 U.S.A.

Preface In 1970, A. Fontijn and his colleagues reported a study on a gas-phase

chemiluminescence reaction of nitric oxide and ozone [1]. The elemental total nitrogen analyzer using a pyro-chemiluminescent nitrogen detection method was developed several years later [2]. The most recent Model 7000N (Part 1) from Antek Instruments Inc. (Houston, Texas, U.S.A.) is available for analyzing nitrogen containing solid, liquid, and gas compounds in an automated analytical laboratory. Total nitrogen on-line process analyzers are also available from Antek Industrial Inc. (Houston, Texas, U.S.A.). The development of the chemiluminescent nitrogen detection for gas chromatography (GC-CLND) was also accomplished by Parks et. al. [2]. The Model 705D has been refined over the years, and additional improvements were incorporated into the new Model 705E. Many thanks to everyone one on Antek's present and past product development and manufacturing teams. Analytical and research applications for GC-CLND has blossomed significantly over the past several years and some examples are discussed in Part 2. Nitrogen detection for simulated distillation (SimDis-CLND) is an important emerging technique and is briefly described in Part 3. Recently, a novel high performance liquid chromatography - chemiluminescent nitrogen detector (HPLC-CLND) was described [3]. Applications using the Model 7000 HPLC-CLND are presented in Part 4 for ion chromatography (IC), reversed-phase HPLC (RP-HPLC); and size exclusion chromatography (SEC) of food grade protein hydrolysates, peptides and free amino acids. Macromolecules such as poly(acrylamide) as large as Mw--6,000,000 dalton have been chromatographed by S EC with dual DRI/CLND detectors (Part 5). In Part 6, professor L. T. Taylor et. al. from Virginia Tech (Chemistry Dept., Blacksburg, VA, U.S.A.) most recently interfaced the CLND to capillary supercritical fluid chromatography (SFC). Although SFC-CLND technique is just budding, using packed columns, the newest technique to date is expected to be in full bloom in the very near future.

In order to provide readers the true capability of the CLND in chromatography, a wide range of applications for spice, food/flavor and

Page 394: Instrumental

377

additive, beverage, biochemical, pesticide, polymer, and petrochemical applications are presented in Parts 1 to 6 of this chapter. This manuscript is intended to update readers to some of the latest CLND techniques in chromatography, and to some extent, serve as a selected compendium of CLND applications. The intent is to inspire and facilitate, new approaches with the CLND to solve difficult research/plant production problems in the food/flavor, biochemical, pharmaceutical, and petrochemical industries.

I would like to acknowledge the other contributors to this manuscript and give a special note of thanks for taking time to share their expertise in chromatography and the CLND.

REFERENCES

1. A. Fontijn, A. J. Sabadell, and R. J. Ronco, Anal. Chem., 42 (1970) 575.

2. R.E. Parks and R. L. Marietta, U. S. Patent 4,018,562, 24 October, 1975.

3. E.M. Fujinari and L. O. Courthaudon, J. Chromatogr., 592 (1992) 209.

Page 395: Instrumental

378

LIST OF CONTRIBUTIONS AND CONTENTS

Part 1 Elemental Total Nitrogen Analyses by Pyro-Chemiluminescent Nitrogen Detection

John. Crnko*, Bob C. Kibler, Eugene. M. Fujinari, Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090, U.S.A.

Part 2 Gas Chromatography - Chemiluminescent Nitrogen Detection: GC-CLND

Eugene M. Fujinari, Antek Instruments Inc., 300 Bammel Wesffield Road, Houston, Texas 77090, U.S.A.

Part 3 Simulated Distillation-Chemiluminescent Nitrogen Detection: SimDis-CLND

Richard J. Young*, Shell Canada Products, Ltd., Scofford Refinery, Fort Saskatchewan, Alberta, Canada Eugene. M. Fujinari, Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090, U.S.A.

Part 4 High Performance Liquid Chromatography - Chemiluminescent Nitrogen Detection: HPLC-CLND

Eugene. M. Fujinari, Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090, U.S.A.

Part 5 The Determination of Compositional and Molecular Weight Distributions of Cationic Polymers Using Chemiluminescent Nitrogen Detection (CLND) in Aqueous Size Exclusion Chromatography

Frank J. Kolpak*, James E. Brady, Hercules Inc., Research Center, 500 Hercules Road, Wilmington, DE 19808, U.S.A. Eugene M. Fujinari, Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090, U.S.A.

Part 6 Chemiluminescent Nitrogen Detection in Capillary S FC Heng. Shi, J. Thompson. B. Strode III, Larry T. Taylor *, Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24060, U.S.A. Eugene M. Fujinari, Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090, U.S.A.

Page 396: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 379

1 Elemental Total Nitrogen Analyses by Pyro- Chemiluminescent Nitrogen Detection

John Crnko*, Bob C. Kibler, and Eugene M. Fujinari

Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090 U.S.A.

1.1 INTRODUCTION

The chemiluminescent nitrogen detection mechanism is described below (Equations 1.1 and 1.2). The total elemental nitrogen analyzers and the various chromatographic CLND techniques collectively have the same detection mechanism.

R 1000~ t

R-N + 02 ~ C02 + R

H20 + -NO (1.1)

�9 NO + 0 3 ~ NO2* --- NO2 + hv (1.2)

Sample components are oxidized at high temperatures (1000 ~ - 1100 ~ C). The nitrogen containing compounds are converted to nitric oxide (-NO), as shown in Equation 1.1. Nitric oxide gas is mixed with ozone (03) in the reaction chamber (Equation 1.2). The resulting nitrogen dioxide in the excited state (NO2*) is formed by this chemical reaction. Light (hv) is emitted as NO2* decays to the ground state NO2. Chemiluminescence is detected by a photomultiplier tube (PMT). The signal is then amplified and recorded on a computer for report generation. The linear detector response using nitric oxide as the standard is shown in Figure 1.1. Linear regression analysis was used for the nitric oxide calibration curve with correlation coefficient = 0.999. Using the same total nitrogen detection scheme above, the various chromatographic CLND instrumentation and techniques (Figure l.2) were evolved. These will be described in the following passages of this manuscript along with meaningful applications.

Page 397: Instrumental

380

Z

O

r~

~x0 �9

Z

40 -

3 0 -

2 O -

1 0 -

J J J

J

J 1 1 ! ! 1 ! i

0 5000 10000 15000 20000 25000 30000 35000

Peak A r e a I n t e g r a t i o n

Figure 1.1 CLND nitric oxide calibration curve.

Elemental Nitrogen Analyzer

GC-CLND Total

HPLC-CLND

SFC-CLr rnDis-CLND

Figure 1.2 Chemiluminescent nitrogen detection.

Page 398: Instrumental

381

1.2 TOTAL NITROGEN ANALYSES

Boehm et. al. reported a collaborative study for the determination of total nitrogen content in urine by pyro-chemiluminescence. Each of the twelve participating laboratories analyzed 5 blind duplicate samples of human urine. The nitrogen content ranged from 650 mg/L to 8800 mg/L. Results showed repeatability standard deviation (RSDr) values from 1.49 to 3.91% and reproducibility standard deviation (RSDR) ranged from 3.66 to 9.57%. The total nitrogen determination by pyro-chemiluminescence method was adopted first action by AOAC INTERNATIONAL [1.1]. Konstantinides describes the chemiluminescence measurement for nitrogen balance studies in the field of clinical nutrition [ 1.2]. Luli et. al. presented submicron assay for proteins, peptides and amino acids [1.3]. An automated chemiluminescent nitrogen analyzer for routine use in clinical nutrition was assessed by Grimble et. al. [1.4]. Pyro-chemiluminescence as a real-time, cost-effective method for total urinary nitrogen (TUN) in clinical nitrogen-balance studies was presented by Konstantinides et. al. [1.5].

Jancar et. al. determined the protein content in beer and wort by pyro- chemiluminescence [ 1.6]. Although, the brewing industry typically estimates the total protein content of beer and wort by the Kjeldahl nitrogen method, the total nitrogen content by Antek pyro-chemiluminescent measurement method demonstrated detection linearity and less than 4% coefficient of variance in the typically observed protein range. The proposed method is rapid (approx. 2 minutes per determination). They reported that the pyro-chemiluminescent nitrogen detection data correlated very well with values by the Kjeldahl method. Hazardous wet chemical reagents are also eliminated by this alternate method.

Hernandez discussed earlier, general applications of total bound nitrogen analysis by pyro-chemiluminescence [1.7]. Nitrogen estimation in biological samples using chemiluminescence detection was reported by Ward et. al. [1.8]. Drushel reported nitrogen content determination by pyro- chemiluminescence in petroleum fractions [1.9]. Figure 1.3 shows a multimatrix elemental total nitrogen analyzer Antek model 7000N. Determination of total bound nitrogen has proven to be important to the petroleum industry. Two ASTM test standards are currently used extensively. D-4629 is a general purpose method for syringeable liquids, while D-5762 is used for viscous materials. Total nitrogen in waste water has proven to be an important control parameter. ASTM test standard D-5176 is used for various aqueous waste streams. An on-line total nitrogen process analyzer model 6000 is also commercially available and shown in Figure 1.4

Page 399: Instrumental

Figure 1.3 Model 7000 N total nitrogen analyzer equipped with the boat inlet option is acceptable for use in ASTM test standards D-4623, D-5176, and D-5762.

Page 400: Instrumental

383

Page 401: Instrumental

384

1. R E F E R E N C E S

1.1 1.2 1.3 1.4

1.5

1.6

1.7 1.8

1.9

K. A. Boehm and P. F. Ross, J. AOAC Inter., 78 (1995) 301. F. N. Konstantinides, Nut. Clin. Prac., 7 (1992) 231. G. W. Luli and S. L. Lee, Am. Biotech. Lab., Feb. (1989).20. G. K. Grimble, M. F. West, A. B. Acuti, R. G. Rees, M. K. Hunjan, J. D. Webster, P. G. Frost, and D. B. Silk, JPEN, 12 (1988) 100. F. N. KonstantinidesK. A. Boehm, W. J. Radmer, M. C. Storm, J. T. Adderly, S. A. Weisdorf, and F. B. Cerra, , Clin. Chem., 34 (1988) 2518. J. C. Jancar, M. D. Constant, and W. C. Herwig, Am. Soc. Brewing Chem. J.., 41 (1983) 158. H. A. Hemandez, Am. Lab., June (1981) 72. M. W. N. Ward, C. W. I. Owens, and M. J. Rennie, Clin. Chem., 26 (1980) 1336. H. V. Drushel, Anal. Chem., 49 (1977) 932.

Page 402: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 385

Gas Chromatography-Chemiluminescent Nitrogen Detection: GC-CLND

2

Eugene M. Fujinari

Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090 U.S.A.

2.1 INTRODUCTION

The chemiluminescent nitrogen detection (CLND) mechanism for chromatography is the same as the total nitrogen detection (Equations 1.1 and 1.2). For GC-CLND, sample components are eluted from the column and then oxidized at high temperatures (1000 ~ 1100 ~ The-NO and 0 3 chemiluminescence detected by the PMT (in Equation 1.2) is proportional to the amount of each nitrogen containing compound eluting from the chromatographic column. Figure 2.1 shows Antek's new GC-CLND Model 704E with the new Hewlett-Packard GC Model HP6890. Applications using both new generation instruments will be reported in the near future.

2.2 SAMPLE INLET AND GC COLUMN

In order to obtain the maximum benifit of the CLND, the chromatographer must quantitatively get the nitrogen containing analytes to the detector. Therefore it is very important that 1) sample injection system such as split/splitless, cool on-column, or valve (sample loop) injection and transfer lines etc., 2) capillary column (also consider: stationary phase, film thickness, column I,D., and length etc.), and 3) interface to the detector (CLND pyro-furnace and transfer line) are clean and fully operational for the type of sample to be analyzed. Although this is very basic, it is the criteria for every successful chromatographic application using any detector and certainly applies to the CLND. Yet more often than not, we sometimes come across an analyte or the sample matrix hanging up (perhaps a portion) somewhere between these three chromatographic entities and causing a problem. The injection port of the GC should be cleaned as needed and the selection of a

Page 403: Instrumental

386

Page 404: Instrumental

387

good column is also of utmost importance. The flow diagram for the GC- CLND is illustrated in Figure 2.2. At the detector, the detector inlet, pyro- tube, transfer line to the reaction chamber, and the entire reaction chamber must also be clean. This will insure optimum nitrogen response for analyte(s) by the CLND. Next, nitrogen to carbon selectivity (N/C) is optimized by providing sufficient pyro-oxygen to convert nitrogenous solute(s) to nitric oxide and the sample to carbon dioxide, water, and other oxides. The flow rate should be adjusted to maximize the nitrogen response to where N/C ratio = 106 or better, increasing ozone will increase the nitrogen response, but an excess will also decrease the nitrogen selectivity (N/C). Therefore, ozone flow rate should also be set at optimum nitrogen selectivity. Under these conditions, the CLND can operate in the nitrogen-specific mode. Applications illustrating the utility of GC-CLND will follow.

2.3.1 GC STATIONARY PHASES

A chromatographic separation study of some nitrogen heterocycles such as A=l-methylindole, B=indole, 1C=3-methylindole, 2C=2-methylindole, D=acridine, 1E=9-methylcarbazole, and 2E=carbazole was pursued to better understand the chromatography of these nitrogen containing compounds [2.1 ]. Figures 2.3 and 2.4 show the structures of GC stationary phases used in this study and the nitrogenous analytes, respectively. GC-CLND was used as the detection method along with 0.32 mm and 0.53 mm I.D. capillary collumns coated with these selected stationary phases. Split (2 ~tL) and splitless (1 laL) injection modes were also tested in this study.

2.3.2 EXPERIMENTAL

Apparatus GC analyses were performed on a GC Model 3000 and Model 705D

nitrogen specific detector (GC-CLND) both from Antek Instruments (Houston, TX, U.S.A.) with a Delta chromatography software from Digital Solutions Pty. Ltd. (Margate, Australia) on an IBM 286 compatible computer. The following widebore and/or megabore capillary columns were utilized in this study (see Table 1): DB-1, DB-5, DB-5MS, DB-17 and DB-210 from J&W Scientific (Folsom, CA, U.S.A.).

Page 405: Instrumental

r - - - - i I I (NOT PAW OF 705D)

GC I INJEClU- I I

I I I I L - -

SEPTUM I 1

SPUTlER 1

I

PURGE

cc CARRIER IN I

- - - - A

COLUMN

MEMBRANE DRYER I PYRO N E E +

I 1 I FURNACE

I I I

0 SCRUBBER

+==+

Figure 2.2 Antek chemiluminescent nitrogen detector GC-CLND flow diagram.

w 00 m

Page 406: Instrumental

389

(•H3 o_s, -! CH3 I n

Dimethylpolysiloxane

c~ ~H2 ~H2

- O - - S i - I

- CH 3 Trifluoropropylmethylpolysiloxane

~ H3 1 ~ I CH3 ~ ~O S, n C6H5

Diphenyldimethylpolysiloxane

Figure 2.3 Sructures of the GC stationary phases.

Page 407: Instrumental

390

A

CH 3

1C=

D _.

CH 3 H

2C= C H 3 ~ ~ H H

1E=

2E =

CH 3

H

Figure 2.4 Sructures of the nitrogen containing analytes: A= 1-methylindole, B=indole, 1C-3-methylindole,

2C=2-methylindole, D-acridine, 1E=9-methylcarbazole, and 2E=carbazole.

Page 408: Instrumental

391

Reagents and Standards The nitrogen containing heterocycle standards were purchased from

Aldrich (Miliwaukee, WI, U.S.A.). Toluene reagent (99+%) was obtained from Fisher Scientific (Fair Lawn, NJ, U.S.A.). All standards and reagents were used without further purification. The 7 analyte standard mixture was prepared in toluene and consisted of the following concentrations: A= 1-methylindole (20.1 ppm), B=indole (14.9 ppm), 1C=3-methylindole (16.0 ppm), 2C=2-methylindole (14.3 ppm), D=acridine (15.4 ppm), 1E=9-methylcarbazole (15.0 ppm), and 2E=carbazole (18.9 ppm) as w/v.

Chromatographic Conditions Helium was used as carrier gas at flow rate of 2.1 mL/min for 0.32 mm

I.D. column and 6 mL/min for 0.53 mm I.D. column. Oven program: temperature 100-250 ~ C at 3 ~ C/min. Detector and injector temperatures were 280~ and 275 ~ respectively. CLND conditions: pyrolysis temperature 1000 ~ PMT voltage 900, range x50 detector output 1 volt. Sample injection techniques and sizes are presented in Figures 2.5 to 2.10. Split ratio of 31/1 was used in the split injection mode.

2.3.3 RESULTS AND DISCUSSION

Since sample introduction and columns are an important part of each and every chromatographic detection, it is worthwhile to spend some discussion on this topic from the CLND point of view using nitrogen containing analytes. In this study, both split and splitless injection modes were tested together with several different stationary phases and results are presented in Table 2.1. The difference in the functional group interaction of each analyte with the stationary phase provides the means for the separation processes. The measure of the amount of separation between two peaks is resolution. Separation numbers (TZ) are valid for a homoligous series of compounds varying by one methyl unit [2.21. Since resolution and separation numbers provide useful information as to the solute to stationary phase interaction, different stationary phases were tested in this study in search for better chromatographic separations of several nitrogen heterocycles.

A mixture containing seven nitrogen heterocycles were analyzed by GC-CLND. Figures 2.5a and 2.5b, show a 1 ~tL splitless injection on a 0.53 mm I.D. DB-5 column and 2 ~tL split injection on a 0.32 mm I.D. DB-5MS column, respectively. The split injections in general provided sharper peaks and the 0.32 mm I.D. column resulted in a better resolution for the carbazoles (peaks D, 1E and 2E). No resolution between 3-methylindole (peak 1C) and

Page 409: Instrumental

Table 2.1

Separation Number TZ and Resolution (Rs) as measure of stationary phase to analyte functional group interactions

Nitrogen Phase: Phase: Phase: Phase: Phase:

Analyies 30mx0.32mm 30mx0.32mm 30mx0.32mm 30mx0 32mm 30mx0.53mm df=1w dfd.5pm dfS.5pm dfd.25pm df=l . 5 ~

Containing DB-1 DB-210 DB--17 DBdMS DB-5

,.~. = l ~ . m e t ~ y l i r i a O l e . . _ ..........

...... ........................................................ ................ ~1-.~~7~,.03~ ............... . . ~ (71-.~4g~ ................ 5 ~ ~ . 7 1 - 1 ~ ~ . 4

................................ , ......................... .7!2.@!.1.!?1 ..................... 4s .. @.5?1 ....................... - ...............................................................................................................................

............................ ,...... ................................ .............. .......................... NF\ ............. &!:.:-::: .............................................................................. ?.C..=..?:??!!T!!dd!? ...................................................................................................................... ........................ ............................................ I

i - i ............................................ .................. ....................................... ~~-.(46-5~-.-~ 1 3 ~ l . . 6 ~ ~ ~

.. _ ........................ :

jEc= ....... ........ 10m8tl) ...... $n.l.,sP, .................................... : . . . . . .................... lJAl!.:.?3

: 1.C._.3_methy!lndo!e.... ......... ".R#,,. .................... ...~3g..56 .............................................................................. NR .........................................

. . ~ ^ ....... ~ .............................. .......... ._ .................. ...... ................................ ._ ...................... i .......................... = acr'dine. ........................................... ............ ._ .................................................. : . . ...... ._ .......... l!?,PS) k??:.431 ........ ...... i?;(B,72) _ il.2:J.2~. ............................. I.!.s,sL ................ ...... ~

..... 1E = 9-methylcarbazole ........................................ ......... ~ ..... -. _j

NR = No resolution observed.

Page 410: Instrumental

A

1 B IIC + 2c

I-

II I a 1-

b

B

1c + 2c

1E

D

c

/-----

I I 1 I I I I t 0 5 10 15 20 25 30 35

time (min)

Figure 2.5 GC-CLND chromatogram of 7 nitrogen heterocycles on a DB-5 stationary phase: a) 1 pL splitless injection, 30 m x 0.53 mm I.D. column; b) 2 pL split (31/1) injection, 30 m x 0.32 mm I.D. column.

w W w

Page 411: Instrumental

394

2-methylindole (peak 2C) was observed. This may be due to the phenyl-like aromatic characteristic of the two methylindoles having similar interaction with the phenyl (5%) groups on the DB-5 stationary phase.

The DB-1 (dimethylpolysiloxane) stationary phase typically used for separating compounds by boiling point showed no resolution between 3- methylindole (peak 1C) and 2-methylindole (peak 2C), similarly between 9- methylcarbazole (peak 1 E) and carbazole (peak 2E), see Figure 2.6.

DB-17 stationary phase contains 50% phenyl (Figure 2.7). When comparing this chromatogram to the DB-5 in Figure 2.5b, the DB-17 phase gave improved resolution (Table 2.1). However, like the DB-5 phase, no resolution between 3-methylindole (peak 1C) and 2-methylindole (peak 2C) was observed even with 10 times more phenyl in the stationary phase than DB-5.

A trifluoropropylmethylpolysiloxane stationary phase (DB-210) provided the best peak resolutions (Table 2.1) and all 7 nitrogen containing compounds were resolved (Figure 2.8). The resolution (39.56) between 3- methylindole and 2-methylindole was accomplished using this column. A separation number between indole and 2-methylindole was measured to be 80 with a very good resolution (95.09). Data indicated that each of the 7 nitrogen bearing compounds interacted to a different degree with the trifluoropropyl- functional group of the stationary phase structure, resulting in good separation.

The elution order of the 7 standards on the DB-210 column was confirmed by standard addition as shown by the GC-CLND chromatograms in Figures 2.9 and 2.10.

2.3.4 CONCLUSION: (to sections 2.3.1 to 2.3.3)

GC-CLND technique was used in effort to search for better chromatographic separation of the 7 nitrogen heterocycles than the typical boiling point (DB-1) column. The trifluoropropylmethylpolysiloxane phase was found to achieve optimum resolution, particularly for the separation of 3- methylindole and 2-methylindole isomers. Both resolution and separation numbers were obtained and provided useful information as to the degree of stationary phase structure-to-analyte functional group interactions. Regarding sample introduction for these 7 compounds, a 2 ~L split injection with a split ratio of 31/1 and a 0.32 mm I.D. (widebore) column was preferred over the 1 I~L splitless injection with the 0.53 mm I.D. (megabore) column. In general, better sensitivity and peak shapes were observed using the split injection for these analytes onto a 0.32 mm I.D. column. Finally, the GC-CLND chromatograms showed optimum nitrogen-specificity. No response to the

Page 412: Instrumental

395

I _

IN

+

IN

§

0 -(~.~

In

-(~1

0 -(~1 C:

m E

E

_U~

-0

0 o~

O

x:E ~.

0 I--, X

o~,,,i 0

,.. ,.o

o'~'~ t=

~ '-~

z~~

!

Page 413: Instrumental

396

I

0 in

0 -(~1

am

E

E

. U') :~

-0

0

i ~.

�9

~o

o~

~

.~

~ �9

t~ E

~

z~

! i..)~

i ~-

o~ o,..~

Page 414: Instrumental

397

r~

~: ......

_ -

~ ~ ~

0 "('3

In

0

m E

0 E

.U

')~

,1 ~

0

-U')

-0

0 =i 0 ~

X

= ~.~ ~

2

z~

!

Page 415: Instrumental

398

0 5 10

lC /

c

. . . . i . . . . . w . . . . . i . . . . . . .

15 .20 25 time (rain)

Figure 2.9 Peak identification by s tandard addition. GC-CLND with DB-210 column, 30 m x 0.32 mm I.D.

2 ~tL split (31 / 1) injection A= 1-methylindole, B=indole, 1C=3-methylindole,

2C=2-methylindole.

Page 416: Instrumental

399

1E

/

5 10 15 20 time (min)

2E

/

25

Figure 2.10 Peak identification by s tandard addition. GC-CLND with DB-210 column, 30 m x 0.32 mm I.D.

2 ~L split (31/1 ) injection D=acridine, 1E=9-methylcarbazole,

2E=carbazole.

Page 417: Instrumental

400

toluene (hydrocarbon) solvent was observed. This allowed the chromatographer to easily identify and rapidly quantitate the nitrogen containing analytes. Detector sensitivity of 12 pg N (1 uL x 100 ppb indole in toluene) with a signal to noise (S/N) ratio of 2/1 was achieved. The next step was to use the nitrogen-specific detector to analyze some real world samples.

2.4 GC-CLND OPTIMIZATION

A direct distillation gasoleum sample spiked with toluene and n-C7 to n-C23 hydrocarbon standards was analyzed by GC-CLND. The purpose was to demonstrate that only the nitrogen containing components in the distillation fraction is observed by the CLND.

Chromatographic Conditions Helium was used as carrier gas at flow rate of 2.0 mL/min. Oven

temperature program was 40-275~ at 4 ~ C/min, hold 2 min. Detector and injector temperatures were 280 ~ C and 275 ~ C, respectively. Column: DB- 1, 30m x 0.32 mm I.D., 1 ~tm film thickness. FID conditions: 1 volt output, range 10E-11, 249 mL/min air, 30 mL/min hydrogen, helium carrier 4.5 mL/min, helium make-up 20 mL/min. CLND conditions: pyrolysis temperature 1015~ PMT voltage 750, range xl detector output 1 volt. A ltttL splitless injection.

Results and Discussion GC-CLND was optimized so that the non-nitrogen hydrocarbon

components in the direct gasoleum fraction was transparent to the detector and only the nitrogen compounds were observed (Figure 2.11a). Total nitrogen content in this sample was 150 ppm N. The corresponding FID chromatogram shows toluene, n-C7 to n-C23 alkanes, and the hydrocarbons of the gasoleum fraction (Figure 2.11 b). GC-CLND application on petroleum light cycle oil (LCO) using a HP-1 (boiling point column) was previously reported [2.31.

2.5 GC-CLND: Flavors and Essential Oils

Benn et. al. applied GC-CLND to selectively detect nitrogen containing compounds in flavors and essential oils [2.5]. Using this technique, a simple method was demonstrated to detect adulteration in food materials. Galbanum

Page 418: Instrumental

401

C7

0

Q)

o

C15

C14

C13

C17 C16

C18

- . . . . . . . . . . . , .

2 0 . . . . . | " ' 40 Time (mini

C19

C20

C21

[C22 3

60 b) GC-FID

0 2'0 40 6b Time (mini

a) GC-CLND

Figure 2.11 Direct distillation gasoleum fraction. DB-1 column, 30 m x 0.32 mm I.D. 1 pL splitless injection a) GC-CLND showing only nitrogen compounds b) GC-FID sample with toluene + n-C7 to n-C23

Page 419: Instrumental

402

oil has a unique leafy odor and is used in low levels in some flavors. Researchers have previously reported FID characterization of pyrazines in galbanum oil [2.6-2.7]. Because of its cost, adulteration by addition of beta- pinene and other terpenes is not uncommon. Addition of 1-(2-pyridyl)-3- chlorophenylpropane (Root Body) may make this type of adultration more difficult to detect during organoleptic evaluation. Figure 2.12a shows FID chromatogram of adulterated galbanum oil. The presence of Root Body in this sample is not apparent by the FID and may not be detected by organoleptic evaluation. Figures 2.12b, 2.12c, and 2.12d are GC-CLND analysis of genuine galbanum oil, adulterated galbanum oil, and Root Body standard, respectively. The chromatogram in Figure 2.12b shows the natural pyrazines as viewed by the CLND. Peak assignments:

B= 2-methoxy-3-isopropylpyrazine, C= 2-methoxy-3-isopropyl-5-methylpyrazine, D=- 2-methoxy-3-sec-butylpyrazine, E= 2-methoxy-3-isobutylpyrazine, F= 2,6-dimethoxy-3-isopropyl-5-methylpyrazine

The CLND of the adulterated galbanum oil (Figure 2.12c) showed peaks A=2,4,6-trimethylpyridine and the Root Body isomers (peaks G, H, and I) in addition to the natural pyrazines. The presence of 1-(2-pyridyl)-3- chlorophenylpropane in the galbanum oil clearly indicated adulteration of the sample.

Figure 2.13a is a GC-FID profile of a natural peach flavor with 2- isopropyl-4-methylthiazole. This additive is a synthetic chemical which, when added to peach flavor at trace levels, provides a full, pleasant note. This same sample was analyzed by GC-CLND (peak A=2-isopropyl-4- methylthiazole) and presented in Figure 2.13c. Note in the FID chromatogram that this additive is co-eluting with a major component of the peach flavor. The GC-CLND profile of only the peach flavor is provided in Figure 2.13b.

Chromatographic Conditions Helium carrier gas flow rate was 10.0 mL/min. Oven program:

temperature 50 ~ C, hold 2 min, ramp to 220~ at 7 ~ C/min, hold 5 min. Detector and injector temperatures were 250 ~ C. Column: CP-Sil 5 CB, 25m x 0.53 mm I.D., 1 tam film thickness (Chrompack Inc., Raritan, NJ, U.S.A.). FID conditions: 1 volt output, 400 mL/min air, 30 mL/min hydrogen, helium make-up 20 mL/min. CLND conditions: pyrolysis temperature 1000 ~ C, PMT voltage 950, range x50 detector output 1 volt. Integrator conditions: 1 volt input, attenuation 2 3 (FID) or 2 8 (CLND). A l laL splitless injection except galbanum oil by FID which used 0.2 tttL splitless injection [2.5].

Page 420: Instrumental

403

| i | - - 1 -

0 10 20 30 Time (rain)

Figure 2.12a GC-FID of adulterated galbanum oil. Reprinted from S. M. Benn, K. Myung, and E. M. Fujinari, G. Charalambous (Ed.), Food Flavors, Ingredients and Composition, Elsevier Science Publishers, Amsterdam, (1993) 65, with permission.

Page 421: Instrumental

404

b. genuine galbanum oil. c. adul terated galbanum

oil. d. Root Body std.

b)CLND

E c

G

D

I " ' ! . . . . . . I '" I

0 10 20 30 Time (min)

.c)CLND

.d)CLND

Figure 2.12b-d GC-CLND of galbanum oils. Reprinted from S. M. Benn, K. Myung, and E. M. Fujinari, G. Charalambous (Ed.), Food Flavors, Ingredients and Composition, Elsevier Science Pu blishers, Amsterdam, (1993) 65,

.... with perm!ssion. .

Page 422: Instrumental

405

a. flavor + 2-1sopropyl-4- methylthlazole.

c. same sample as l a. b. peach flavor only.

LJ a) FID

c) CLND

- ~ - - ~ b) CLND I . . . . . . i . . . . . D . . . . . l -

0 10 Z0 30 T i m e (rain)

Figure 2.13 GC-FID and GC-CLND of peach flavor. Reprinted from S. M. Benn, K. Myung, and E. M. Fujinari, G. Charalambous (Ed.), Food Flavors, Ingredients and Composition, Elsevier Science Publishers, Amsterdam, ( 1993 ) 65, with permission.

Page 423: Instrumental

406

2.6 GC-CLND: Hydrocrackite Hydrocarbon Standard

GC-FID hydrocrackite hydrocarbon standard profile, containing 23.72% paraffins, 56.56% naphthenes, 16.94% aromatics, and 2.78% unidentified olefins, is presented in Figure 2.14. This standard mixture contains no nitrogenous compounds as shown by the corresponding GC- CLND chromatogram after detector optimization, Young et. al. [2.8].

Chromatographic Conditions Helium carrier gas flow rate was 2.0 mL/min. Oven program:

temperature 35-235~ at 4 ~ C/min. Detector and injector temperatures were 285~ and 280 ~ C, respectively. Column: DB-1, 30m x 0.32 mm I.D., 1 ~tm film thickness. FID conditions: 1 volt output, range 10E-12, 262 mL/min air, 25 mL/min hydrogen. CLND conditions: pyrolysis temperature 1000 ~ PMT voltage 850, range x50 detector output 1 volt. A 0.2tttL splitless injection (FID) and 0.4 laL splitless injection (CLND).

2.7 GC-CLND: Light Cycle Oil 0LCO)

The chromatographic optimization of the 7 nitrogen containing standards is presented in the previous GC stationary phase study (section 2.3.1-2.3.4). The 7 nitrogen heterocycle standards and the LCO fraction, after column and CLND optimization, are presented in Figures 2.15a. and 2.15b, respectively. DB-210 phase does not elute solutes strictly by boiling point as the dimethylpolysiloxane phase. The trifluoropropylmethylpolysiloxane GC stationary (DB-210) support, however, provided excellent resolution of the three methylindole isomers (peaks: 1= 1-methylindole, 3=3-methylindole, and 4=2-methylindole). For this reason, GC-CLND analysis of the LCO fraction was pursued using the DB-210 column.

Chromatographic Conditions Helium carrier gas flow rate was 2.0 mL/min. Oven program:

temperature 100-250~ at 3 ~ C/min. Detector and injector temperatures were 280~ and 275 ~ C, respectively. Column: DB-210, 30m x 0.32 mm I.D., 0.5 ~m film thickness. CLND conditions: pyrolysis temperature 1025 ~ C, PMT voltage 700, range x25 detector output 1 volt. A 1 laL splitless injection.

Page 424: Instrumental

C 6 $.

1, GC-FID

c10

L GC-CLND -

0 5 10 15 Time (min)

3 0 m x 0.32 mm I.D., 1 pm film thickness, DB-1 column. Note: peaks marked C5 to C 1 0 are n-alkanes.

Figure 2.14 GC-FID and GC-CLND chromatograms of a hydrocrackite hydrocarbon standard

Page 425: Instrumental

408

I - - I . . . . . . . . 1 - - I

0 20 40 60 Time (rain)

b) GC-CLND of LCO

2 7

3 6

4 5

I . . . . . . . . . . . . . . I . . . . . . . - ~ - " I " " - . . . . . . . . .

0 20 40 60 Time (rain)

a) GC-CLND of 7 stds

Figure 2.15 GC-CLND of petroleum light cycle oil. a) Nitrogen containing standards:

Peaks: l=l-methylindole, 2=indole, 3=3-methylindole, 4=2-methylindole, 5=acridine, 6=9-methylcarbazole, and 7=carbazole

b) Petroleum light cycle oil fraction.

Page 426: Instrumental

409

2.8 GC-CLND: LCO Gasoleum and Distillation Fraction

GC-CLND of l ppm N indole standard in toluene, direct distillation gasoleum fraction, and LCO gasoleum are presented in Figures 2.16a, 2.16b and 2.16c, respectively. Note that the light cycle oils (early eluting peaks) present in Figure 2.16c are no longer present after the distillation (Figure 2.16b). The FID profile of this distillation gasoleum fraction is provided in Figure 2.11b. The CLND is only detecting the nitrogen components in the two samples (Figures 2.16b and 2.16c) since the spiked hydrocarbon standards n-C7 to n-C23 and toluene are not observed.

Chromatographic Conditions Helium carrier gas flow rate was 2.0 mL/min. Oven program:

temperature 40-275~ at 4 ~ hold 2 min. Detector and injector temperatures were 280~ and 275 ~ respectively. Column: DB-1, 30m x 0.32 mm I.D., 1.0~m film thickness. CLND conditions: pyrolysis temperature 1015~ PMT voltage 750, range xl, detector output 1 volt. A 1 taL splitless injection.

2.9 GC-CLND: Photo-Active Compounds

GC-CLND of photo-active compounds in methanol are presented in Figure 2.17. Peaks: A=Harmane (83.4 ng), B=Harmaline (78.0 ng), and C=Harmine (114 ng). The stuctures are presented below.

H CH3 H C~3 H C~ 3

Harmane Harmine Harmaline

Harmane is one of many light-activated naturally occuring biocide [2.9]. In general, these types of compounds activate (biochemically) against microorganisms, insects, nematodes, snails, and fish. Harmane alkaloids, type I photosensitizers, have been found to undergo fugicidal activity via possible

Page 427: Instrumental

410

i c) G C - C L N D r . . . . . . . . . . , L C O g a s o l e u m o 80

T i m e ( m i n )

• • b) G C - C L N D

, . . . . , " D i r e c t d i s t i l l a t i o n 0 2() 40 6() g a s o l e u m

T i m e ( ra in )

a) G C - C L N D J- " -~ ' - . . . . . . . . . , ' , l n d o l e s t d 0 20 40 60 1 p p m N

T i m e ( m i n )

Figure 2.16 GC-CLND of direct distillation fraction from LCO gasoleum. a) l ppm N indole standard in toluene b) direct distillation gasoleum fraction c) LCO gasoleum

Page 428: Instrumental

4 1 1

A

I ' C

I

0

B

I . . . . . . . . ! . . . . . . . . . . . . . . . . . . �9

4 8 12 time (rain)

Figure 2.17 GC-CLND of photo-active compounds. Peaks: A=harmane, B=harmaline,

C=harmine. 15m x 0.32 mm I.D., 0.5 ~m film thickness, DB-17 column.

Page 429: Instrumental

412

photo-binding mechanism to DNA.[2.10-2.11]. The analysis of these and related compounds can be obtained by gas chromatography and detection using CLND.

Chromatographic Conditions Helium carrier gas flow rate was 1.5 mL/min. Oven program:

temperature 100-260~ C at 30 ~ C/min., 260-280 ~ C at 4 ~ C/min, hold 10 min. Detector and injector temperatures were 280~ Column: DB-17, 15m x 0.32 mm I.D., 0.5~tm film thickness. CLND conditions: pyrolysis temperature 1000 ~ C, PMT voltage 950, range x25, detector output 1 volt. A 2 ~L split (51/1) injection.

2.10 GC-CLND: 4-Formylmorpholine in Benzene

Determination of 4-formylmorpholine in benzene by GC-CLND can be easily accomplished without hydrocarbon interference. The detector linearity using a four point calibration was obtained from 0.1 ppm to 10 ppm. Linear regression analysis was calculated (r = 99991, m = 0.00264, and b = -0.12215) where r = correlation coefficient, m = slope, and b = y-intercept [2.12].

Nitrogen specific detection was demonstrated with a mixture of benzene (50%) and other hydrocarbons such as toluene (10%), n-decane (20%), and xylenes (20%) containing three nitrogen containing compounds: A--4-formylmorpholine, B=indole, and C=3-methyl indole. The mixture was analyzed by GC-CLND and FID as shown in Figure 2.18 [2.12]. FID showed one large hydrocarbon peak, masking the 3 nitrogen containing compounds. However, the hydrocarbons were transparent to the CLND, unveiling the 3 analytes.

Chromatographic Conditions Helium carrier gas flow rate was 6.4 mL/min. Oven program:

temperature 70-220~ at 30 ~ hold 1 min. Detector and injector temperatures were 220~ respectively. Column: SUPEROX (Carbowax 20M), 10m x 0.53 mm I.D., 1.2 tam film thickness. FID conditions: 1 volt output, range 10E-12, 252 mL/min air, 25 mL/min hydrogen. CLND conditions: pyrolysis temperature 1000 ~ PMT voltage 950, range x50, detector output 1 volt. A 1 ~L splitless injection.

Page 430: Instrumental

413

FID

A

i . . . . . . . . l " i

0 3 6 time (min)

CLND

Figure 2.18 GC-CLND and FID of a hydrocarbon mixture: benzene (50%), toluene (10%), n-decane (20%), xylenes (20%), and three nitrogenous compounds: A=4-formylmorpholine, B=indole, and C=3-methylindole Reprinted from E. M. Fujinari, G. Charalambous (Ed.), Food Flavors, Ingredients and Composition, Elsevier Science Publishers, Amsterdam, (1993) 31, with permission.

Page 431: Instrumental

414

2.11 GC-CLND: Liquified Petroleum Gases (LPG) of Refinery Streams

Liquified petroleum gases (LPG) can be analyzed by GC-CLND to detect low levels of nitrogenous contaminants such as acetonitrile in refinery streams. Flow diagram for the LPG/GC-CLND analysis is provided in Figure 2.19. The sample bomb is pressurized to 250 psi with argon (or another inert gas) and is filtered through a 5 ~m (or 3 tam) particulate filter, on-line to a sample (2~tL loop) valve. LPG sample is passed throught the quartz sight glass and vented until no gas bubble is observed in the liquid sample. Valve is switched and 2txL sample is swept into the GC split/splitless injector using the helium carrier gas (note: study the flow diagram to your GC's split/splitless injector for best sample introduction mode). Sample is chromatographed on a capillary column and the nitrogen containing compound(s) is detected by the CLND (see Figure 2.2, GC-CLND flow diagram). For the analysis of acetonitrile standard, 2tttL of acetonitrile in toluene may be injected into the GC split/splitless injector for calibration with the CLND. The advantages of this method is that 1) the stability of standards may be much better in liquid solution than in a gas balance, 2) preparation of calibration standards and cold storage of the liquid standard solution(s) are simple and convenient, and 3) ease of injecting liquid standard solutions for generating calibration curves for LPG analysis.

2.12 LPG/GC-CLND: MTBE C4 Feed Stream and Depropanizer Bottoms

LPG analysis using GC-CLND of a toluene blank, MTBE C4 feed stream, and an acetonitrile (1.5 ppm) standard in toluene are presented in Figures 2.20a , 2.20b and 2.20c, respectively. Peak A is the acetonitrile analyte. Note that a minor (second) nitrogen component is also present in the MTBE C4 feed stream. Similarly, LPG analysis of depropanizer bottoms (main unit), depropanizer bottoms (auxiliary unit), and an acetonitrile (1.5 ppm) standard in toluene is shown in Figures 2 .21a , 2.21b and 2.21c, respectively. See Table 2.2 for results and linear regression analysis of acetonitrile calibration by the CLND. Figure 2.22 is the acetonitrile standard curve using the CLND and 2tttL splitless injections.

Page 432: Instrumental

I ACETONITRILE I ’ STANDARD I I CAUBRAllON 1 CARRIER

I

T---’ I L---

3 I

I I

I [ ,--LOAD LPC SAMPLE LOAD LPC SAMPLE

3 GC INJECTOR

SAMPLE VALVE Y I

SAMPLE VALVE

NECDLE V A L E (- SIGHT GLASS

VENT TO HOOD

CC-CLND

Model 7050

m - J J I } i l COLUMN COMPUTER PRINTER

Figure 2.19 Liquified petroleum gas (LPG) and GC-CLND application for refinery streams.

Page 433: Instrumental

416

IN

0

Z .,., .c_ E

~

--

o- ~ .s

~_.n~ �9 '~--

0

�9 ~o ~

Otil~

~Z

~E

Eo. 0. o.

u

~

..1"

z~" ,xl::

~c5 r

-v

.Q

to

(19

O

t-, ! N

o ~ ~

N

~

o~M

I

nO

z~

C~

r--I

�9

~tt~ ~c5

~ ,..d

O

c",l

c,i

Page 434: Instrumental

417

0 0 0

~_ma

~--

z~

EEE

~00

~oo

�9

~00

ONN

ooo

o00

~nO

z~

z~

z~

oZ

o o

~E

~E

~E

E~

E ~ n E

o Clio

CI~

0 .Q

~..,v T--V

T--V i

8

d~

-v.-q

~ ~0 o~,~

Page 435: Instrumental

41

8

\ "%, \.

Q

"\.

"\. "%~. \

",~. %..

\ N.. N. %.. "\

""~

N ~

O

~

c2~

0 0 0 0 d ! II

;d O

O

O

O

O

d II E

.N

~ �9

~.~ .i.,,.I

~N

-1,'-4

�9

r M

Page 436: Instrumental

419

Table 2.2

LPG/GC-CLND analysis of MTBE C4 feed stream and depropanizer bottoms.

o,~,,,,~,.,, Acetonitrile Sample Integration Acetonitrile Acetonitrile I i t l b ' l 1 1 1 q~"II ,,7

gas/LPG standard size of samples ppm ~L peak area Lag N ppm N

0.25 2 114.74 0.0005 0.50 2 424.10 0.0010 1.00 2 746.96 0.0020 3.00 2 2103.64 0.0060 5.00 2 3393.83 0.0100

MTBE C4 feed stream 2 263.03 0.00068 0.34 Depropanizer bottom 2 360.16 0.00096 0.48 (main unit) Depropanizer bottom 2 364.49 0.00098 0.49 (auxiliary unit)

Samples were calculated bt linear regression analysis: r = 0.999073 m = 0.0(0)003 b = -0.000098

Chromatographic Conditions Helium carrier gas at flow rate of 10.4 mL/min. Oven program:

temperature initial hold 10 min, 40-180 ~ C at 20 ~ C/min., hold 15 min. Detector and injector temperatures were 220~ and 200 ~ Column: DB- WAX, 30m x 0.53 mm I.D., 1.0pxm film thickness. CLND conditions: pyrolysis temperature 1050 ~ C, PMT voltage 900, range x50, detector output 1 volt. A 2 ~L splitless injection was used for the acetonitrile standard in toluene solutions. Sample (2 [aL loop) valve injection was used for the refinery LPG sample.

Page 437: Instrumental

420

2.13 GC-CLND: Depentenizer Feed and Overhead

GC-CLND of an acetonitrile (10 ppm) standard in toluene, depentenizer feed, and depentenizer overhead are presented in Figures 2.23a, 2.23b and 2.23c, respectively. Samples were introduced in a typical GC fashion using a syringe with a l taL split injection. Peak A.is the acetonitrile analyte.

Chromatographic Conditions Helium carrier gas at flow rate of 2.0 mL/min. Oven program:

temperature initial hold 10 min, 40-180~ at 20 ~ hold 15 min. Detector and injector temperatures were 250 ~ C. Column: DB-1, 30m x 0.32 mm I.D., 1.0~m film thickness. CLND conditions: pyrolysis temperature 1000 ~ C, PMT voltage 800, range x50, detector output 1 volt. A 1 taL split (30/1 ratio)injection.

2.14 GC-CLND: N'Nitrosonornicotine in Cigarette Smoke Extract

Fine et al. reported a TEA method of catalytic low-temperature oxidation for determination of nitroso compounds [2.13-2.14]. However, the nitrosamine detection mechanism by the CLND is depicted (equation 2.1)

I !

R2N '--:- N - O I I

Bond cleavage

500~ ~-- "NO + R2N" (2.1)

by a thermal (450 ~ 650 ~ C) bond cleavage without a catalyst to generate nitric oxide [2.3]

Determination by GC-CLND of N'Nitrosonornicotine (peak A - NNN) in cigarette smoke extracted into methylene chloride is given in Figure 2.24 [2.12]. The structure of NNN is also provided in the figure.

Page 438: Instrumental

421

e- ll)

m o

�9 ~ .c_

A~

A

< <

i m

m

~ ~E

C C~

L~

N

Page 439: Instrumental

4 2 2

I NO

A

i i J 5 10 15

Time (min

Figure 2.24 GC-CLND of cigarette smoke extracted in methylene chloride. Peak A = N'Nitrosonornicotine Reprinted from E. M. Fujinari, G. Charalambous

(Ed.), Food Flavors, Ingredients and Composition, Elsevier Science Publishers, Amsterdam, ( 1993 ) 31, with permission.

Page 440: Instrumental

423

Chromatographic Conditions Helium carrier gas at flow rate of 1.3 mL/min. Oven program:

temperature 165 ~ C, hold 10 min, 165-220 ~ C at 2~ hold 10 min. Detector and injector temperatures were 290~ and 220~ respectively. Column: HP-1, 10m x 0.53 mm I.D., 0.88 lam film thickness. CLND conditions: pyrolysis temperature 500 ~ PMT voltage 950, range x50, detector output 1 volt. A 2 tttL splitless injection.

Page 441: Instrumental

424

2. REFERENCES

2.1 E. M. Fujinari, presented at the 32nd Annual Eastern Analytical Symposium, in Optimizing Gas Chromatography: Theory and Practice Session, "Nitrogen-Specific Detection by Capillary GC-CLND", Somerset, N.J., November 15-19, 1993.

2.2 W. Jennings, "Gas Chromatography with Glass Capillary Columns," Academic Press, N.Y, (1980) 110.

2.3 L.O. Courthaudon and E. M. Fujinari, LC-GC, 9 (1991) 732. 2.4 L.O. Courthaudon and E. M. Fujinari, Figure 1 correction, ibid., 10

(1992) 293. 2.5 S. M. Benn, K. Myung, and E. M. Fujinari, in "Food Flavors,

Ingredients and Composition", G. Charlambous (Ed.), Elsevier Science Publishers, Amsterdam, (1993) 65.

2.6 A.F. Bramwell, J. W. K. Burrell, and G. Riezebos, Tetrahedron Lett., 37 (1969) 3215.

2.7 J. W. Burrel, R. A. Lucas, D. M. Michalkiewicz, and G. Riezebos, Chem. Ind. (London), (1970) 1409.

2.8 R.J. Young and E. M. Fujinari, unpublished work. 2.9 Y.Y. Marchant, "Light- Activated Pesticides", J. R. Heitz and K. R.

Downum (Eds.), ACS Symposium Series 339 (1987) 168. 2.10 G.H.N. Towers and D. E. Champagne, ibid. ACS Symposium Series

339 (1987) 231. 2.11 G.H.N. Towers and Z. J. Abramowski,.J. Nat. Prod., 46 (1983) 576. 2.12 E.M. Fujinari, in "Food Flavors, Ingredients and Composition", G.

Charlambous (Ed.), Elsevier Science Publishers, Amsterdam, (1993) 31.

2.13 D.H. Fine, F. Rifeh, D. Lieb, and D. P. Rounbehler, Anal. Chem., 47 (1975) 1188.

2.14 D.H. Fine, F. Rifeh, D. Lieb, and F. Rufeh, J. Chromatogr., 107 (1975)351.

Page 442: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 425

Simulated Distillation-Chemiluminescent Nitrogen Detection: SimDis-CLND

3

Richard J. Young a *and Eugene M. Fujinari b

aShell Canada Products, Ltd., Scotford Refinery, Fort Saskatchewan, Alberta, Canada

bAntek Instruments Inc., 300 Bammel Wesffield Road, Houston, Texas 77090 U.S.A.

3.1 INTRODUCTION

The nitrogen boiling point distribution of refinery streams can be studied by simulated distillation with a chemiluminescent nitrogen detector (SimDis-CLND) to improve the production of fuels and petrochemicals. Some of the valued features of the CLND for SimDis are: high sensitivity and selectivity of the detector for nitrogen containing compounds. Detailed information is presented in the original paper [3.1]. Some petrochemical GC applications using the CLND have been reported by Britten [3.2].

3.2 SimDis: Hydrocarbon Calibration with AED

Simulated distillation is often used for estimating the hydrocarbon boiling range distribution of the petroleum fractions in order to control the efficiency of the plant refining processes [3.3]. The application using a multielement simulated distillation software for the atomic emission detector (AED) was reported by Quimby and Dryden [3.4]. The AED was used to first calibrate the hydrocarbon (standards) boiling point (-89 to 522~ distribution from C2 to C40 using both carbon and hydrogen detection modes. (see Figure 3.1).

Page 443: Instrumental

426

(I) E

.....

c- O

.m

c (I) L

.

co 0

> Z _J

a2 o

c~ f-

0

Z

o9 (D E

~ c 0 . ...... .4--.,

(D (I) I.=

to >

i~ tu

m c o

_Q

c) o I._.

-0 -I-

(6~c) (~cc) ( (,~)

'~ (z(~)

\

(0t~) \ (~0~1 (~c~)

(z~;) 0~a

(99G)

~E

O\

19111010

(to~) ~

(~) ~o

~

C~)

~ \

(~) ~a

\ (~t[)

0[o \

(~) 6o

\

~ ~

~ :~

oo o

o o

Oo

o C E E c"

o 0 q) l-

~

~ E

~ E

o r,l

0 ~

~ C

< -~

c <

~ 0

~ "~'

~ �9

Rd ~~

~=

~0

(Oo) lU!Od 13U!l!OEl

Page 444: Instrumental

427

3.3 SimDis: Nitrogen Calibration with CLND

A simulated distillation method with the CLND was then developed using matched capillary columns (as AED) in the same GC oven. Simultaneous automated sample injections (one injection to CLND and the other to AED) were accomplished using two separate HP7673A systems mounted on a single HP5890 GC. The CLND was used to calibrate the nitrogen boiling point distribution from 171 to 349~ Figure 3.1. Table 3.1 shows a 4% RSD of the area counts per nitrogen using the CLND for the boiling point distribution range of 171 to 349 ~ C.

Table 3.1

Nitrogen compounds used for SimDis nitrogen boiling point distribution.

N B.P. Compound Area count (ppm) (o C) per N

5.07 171 2,4, 6-Trimethylpyridine 301,142 5.00 184 Aniline 299,713 5.04 210 Nitrobenzene 313,801 5.00 232 4-Chloroaniline 308,969 5.01 254 Indole 299,890 5.02 273 4-Nitroanisole 313,899 2.02 334 1,7-Phenanthroline 111,281 5.01 349 Phenanthradine 301,147

4% RSD

Reprinted from R. J. Young and E. M. Fujinari, Am. Lab., October (1994) 38, with permission.

Chromatographic Conditions Helium carrier gas flow rates were 3.5 mL/min for both AED and

CLND. Oven program: temperature initial hold 1 min, 35-350~ at 10 ~ C/min., hold 7.5 min. Detector bases were both 350 ~ C. Columns: both HP-1, 25m x 0.32 mm I.D., 1.051ttm film thickness. CLND conditions: pyrolysis temperature 1090 ~ PMT voltage 750, range x l0, detector output 1 volt.

Page 445: Instrumental

428

I~ I~

Z LM

ILl ...I

< <

< o

~PIJInaIpT~qnfl- ~

i _

~ueaapeaqaX

~ _~ _

~aueaapoo 0

~qaaOT~lai~ I

~ .

~ ,_

,-

o,

i- ueoaonij- ~

.,_

auanT ~

!2

o~

.~

kJ

0

o~

0

i -

~ ~

~ ~

�9 .

: _~

~ <::

.~

-~ F

~ ~h~

c .o

~

~ ..~~

if: ~.a,

.-

-- ~

~~

~ ~

~ ~

-~ ~

~ ~

~ ~

~ -~

~ ~

~ .

eq e~

o~

u.

Page 446: Instrumental

429

D El

121 Z

W W

W -J

o"1

c-

0 , ,..,,

c @

�9

(NI

�9

"a .i..-I

,,I....I

o= "~= ~~ ,.,....,

.~ o~ o,.4~

r,n �9

t~

o

ov,,,,l

Page 447: Instrumental

430

Simultaneous 0.1 tttL cool on-column injection at 35~ using two robotic autosamplers (HP7673A) for the same C~ oven (HP5890 GC).

3.4 SimDis-CLND: Simulated Distillation of Refinery Streams and Products

In a refinery process, certain types of catalysts may be poisoned by nitrogen bearing compounds. Detection and removal of the nitrogen compounds can result in prolonged catalyst life. The purpose here is to demonstrate the nitrogen detection technique for simulated distillation. In this application, gasoline was fortified with components containing 90-100 ppm N which elute within the nitrogen boiling point calibration. A SimDis AED checkout for the C, H, and S modes is shown in Figure 3.2. The corresponding N mode by the CLND shows only nitrobenzene. Total nitrogen found by the CLND was 90 ppm N in the spiked gasoline (Figure 3.3). The N distribution is clearly different from the AED's C, H, and S detection modes. Because of the high sensitivity and nitrogen-specificity of SimDis-CLND, the technique can be useful to study refinery streams and final products.

3. REFERENCES

3.1 3.2 3.3

3.4

R. J. Young and E. M. Fujinari, Am. Lab., October (1994) 38. A. J. Britten, R&D, 31 (1989) 76. ASTM standards: D2887-93. Standard test method for boiling range distribution of petroleum fractions by gas chromatography. Philadelphia, PA, 1993. B. D. Quimby and P. C. Dryden, Multielement simulated distillation with HP 5921A atomic emission detector. Application note 228-205. Avondale: Hewlett-Packard, 1992.

Page 448: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 431

4 High Performance Liquid Chromatography- Chemiluminescent Nitrogen Detection: HPLC-CLND

Eugene M. Fujinari

Antek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090 U.S.A.

4.1 INTRODUCTION

The chemiluminescent nitrogen detection (CLND) mechanism for high performance liquid chromatography (HPLC) is the same as in Equations 1.1 and 1.2. Although the detection mechanism is the same for elemental total nitrogen analyzer (section 1.1) and GC-CLND (section 2.1), HPLC-CLND was developed for handling HPLC mobile phases and subsequent nitrogen detection. Schematic flow diagram for HPLC-CLND and photograph of the detector are shown in Figures 4.1a and 4.1b, respectively. Configurations of the dual HPLC-CLND and UV detection with a 4.6 mm I.D. analytical column are shown in Figures 4.2 and 4.3. In the former configuration, the HPLC-CLND and fraction collection are accomplished post-UV detection. In this case, a high pressure UV cell is recommended. More common set-up is shown in Figure 4.3, where CLND and UV detection are accomplished with a post-column split. Three types of splitters have been used: 1) Y-splitter (Valco), T-splitter (Keystone Scientific), and capillary GC splitter (SGE). All three splitters worked well. Most significant reason for using HPLC-CLND is that amines (primary, secondary, and tertiary, as well as quaternary ammonium) attached to compound which do not contain UV chromophore(s) are difficult to detect by conventional UV detectors. On the other hand, CLND can readily detect amines and other nitrogen containing compounds. An example is given in Figure 4.4a, piperazine, nitrogenous compound, does not have UV chromophore within its molecular structure, and consequently not observed by UV (254 nm) detection. Piperazine (peak A) without derivatization was easily detected by CLND as shown in Figure 4.4b [4.1]. Analysis of ammonium nitrogen in waste water was described earlier by HPLC-CLND [4.2]. The reported method utilized an ion chromatography (IC) column for cation separation.

Page 449: Instrumental

432

' I

! i ! ! ! I I I ! D

~

Zl

I

I: 1 (D

: .._Jl a.i -l-: I 1 1 I I I I I I I

(/i

i

w~

' i_

I I I I ' I

: i

I I t I 1 I I L_ ..

..

..

..

.

I I I i ! I ! I ! ! ! i i ! i ! i i i ! i i ! L 0

~ !

"r" , ! ! ! i !

d

d.,.a

qJ

:::s

< c~

c~

"o

�9

Z I

c~

qa

~162

~T~

Page 450: Instrumental

433

Page 451: Instrumental

434

a o

..I 0 L

.

0

4-1

r~

_L_

! ) () 3 ) ~

1

m

--.

I1. ca

"r

m

L.

u- 0

,< =- 0

~ ;>

z I

,.d

r o~,.~

Page 452: Instrumental

435

i

(' I S

t::: a.

|

~E

IX

, In

< �9

> z ,.d !

r,.) ,..d

Page 453: Instrumental

436

B

A

| . . . . . ! I

0 5 10 Time (mln)

A

B

~ _ _ L _ i i . . . . . . i "- )

0 5 10 Time (rain)

N ~ Et

Et

2 , 3 - D i e t h y l p y r a z i n e

a) UV (254 nm)

N

P i p e r a z i n e

b) CLND

Figure 4.4 RP-HPLC of a two s tandard mixture. Peak A = piperazine which does not have a UV Chromophore , 13 = 2,3-diethylpyrazine. Reprinted from E. M. Fujinari and J. D. Manes, J. Chromatogr. A, 676 (1994) 113, with permission.

Page 454: Instrumental

437

Anions such as nitrite and nitrate ions have also been separated by IC and detected by CLND (Figure 4.5).

1.00

.75 V o I .50- t s

.25-

NO- 2

NO 3

t ime (min)

Figure 4.5 HPLC-CLND trace of nitrite and nitrate ions. Reprinted from E. M. Fujinari and L. O. Courthaudon, J. Chromatogr., 592 (1992) 209, with permission.

In the following sections 4.2 and 4.3, high performance liquid chromatography - chemiluminescent nitrogen detector (HPLC-CLND) is demonstrated, as a tool which can provide the means to facilitate an analytical method development process. Reversed phase HPLC-CLND technique is presented where ethylene thiourea (ETU) standard is fortified in

H N

~ N H

Ethylene thiourea

Page 455: Instrumental

438

apple juice and recoveries analyzed after sample clean-up. Since sample preparation is also a very important part of most analytical processes, a relatively new solid phase extraction method using the SPEC-Microcolumn technology was demonstrated. Microcolumn is a solid phase extraction disc having more surface area than particles which are used in most solid phase extractions (SPE). A preliminary apple juice ETU recovery study using Microcolumn clean-up followed by HPLC-CLND analysis is discussed. CLND results were also compared to data obtained by UV detection.[4.3].

4.2 EXPERIMENTAL

Apparatus High performance liquid chromatographic separations were achieved

on a microbore HPLC system: pump Micromeritics Model 760 from Alcott Chromatography (Norcross, GA, U.S.A.). Sample injections were achieved with a 20 ~L loop on a Model 9125 injection valve from Rheodyne (Cotati, CA, U.S.A.). BDS-Hypersil-C18 microbore HPLC column was purchased from Keystone Scientific Inc. (Bellefonte, PA, U.S.A.). Sample clean-up was achieved by soild phase extraction on (SPEC-47-C18AR and SPEC VC MP3) SPEC-Microcolumns from SPEC, a Division of ANSYS, Inc. (Irvine, CA, U.S.A.). The detection and quantitation of ETU analyte was accomplished with the nitrogen specific detector, model 7000 HPLC-CLND, from Antek Instruments Inc. (Houston, TX, U.S.A.) and Delta chromatography software from Digital Solutions (Margate, Australia) run on an IBM 286 compatible computer. The variable wavelength UV spectrophotometric detector Model 770 from Spectra-Physics (Santa Clara, CA, U.S.A.) was also used in this study.

Reagents and Standards The ethylene thiourea (ETU) analytical standard was obtained from

Aldrich (Miliwaukee, WI, U.S.A.). HPLC grade methanol (99+%) were obtained from Fisher Scientific (Fair Lawn, NJ, U.S.A.). Sodium free distilled water was obtained from Ozarka Drinking Water Co. (Houston, TX, U.S.A.). All standards and reagents were used without further purification. HPLC mobile phase was filtered through a Millipore (Bedford, MA, U.S.A.) HV filter with a 0.45 lam pore size.

Standards and Analytical methods Aqueous analytical standard solutions (0.5, 1.0, 2.0, 10.0, and 20.0 ppm,

w/v) ETU were prepared and analyzed by HPLC-CLND with a 6 laL partial filled injections (using a 20 [aL sample loop) to a BDS-Hypersil-C18

Page 456: Instrumental

439

microbore column: 150mm x 2mm ID, 5 lttm particle size. An isocratic mobile phase (MP) methanol/water (5:95 v/v) mixture was utilized with a flow rate of 200 ~tL/min. The CLND conditions were" 1050~ pyrolysis temperature, PMT voltage 750, range x50, and detector output 1 volt. SPE conditions: first, a 47 mm disc C18AR SPEC-Microcolumn was used. The solid phase was activated with 2 x 5 mL methanol followed by 2 x 5 mL water. A 100 mL apple juice containing 10 ppm ETU was extracted using a vacuum (1 inch Hg) manifold at a flow rate of approx. 1 drop/sec. The eluent contained ETU + water soluble juice components, leaving behind the methanol soluble components. Next, VC MP3 SPEC-Microcolumn (with 15 mg capacity) was used for additional clean-up. The MP3 phase was activated with 3 x 1 mL water. Then 1 mL of the recovery (10 ppm ETU) apple juice extract from C18AR SPE was added to the MP3 solid phase and eluted slowly, 0.5 mL of a 3% acetic acid methanol/water (50:50 v/v) solution was added. Both eluent (total of 1.2 mL) was collected and analyzed by HPLC- CLND and UV (240 nm) detection. Control apple juice (25 g) was similarly extracted by microcolumn SPE and analyzed by this method.

4.3 RESULTS AND DISCUSSION

Solid phase extraction portion of this study was facilitated by using the SPE method development flow chart Figure 4.6. Stationary phases are selected based on solubility of analyte in various solvents. ETU (10 mg) was soluble in 1 mL water. In similar solubility tests, ETU dissolved in 1 mL methanol, but not in methylene chloride (1 mL). Figure 4.6 indicated that group 3A: SCX, SAX, CN, and NH 2 solid phases should be tested to obtain the most efficient extraction for the ETU analyte. Clean-up procedure with microcolumn solid phase extractions of ETU in apple juice, followed by HPLC-CLND, are outlined in Figure 4.7. Two microcolumns were used in series. First, 100 mL apple juice containing 10 ppm ETU was extracted on a 47 mm (diameter) C18AR microcolumn. Next, 1 mL aliquot of the aqueous eluent was further extracted on a VC MP3 (15 mg) microcolumn. SPEC VC MP3 is a moderately polar SCX solid phase. The addition of 0.5 mL of a 3% acetic acid in methanol/water (50:50 v/v) solution was used to help improve ETU recovery. The combined eluent, aqueous juice fraction, and the 3% acetic acid solution were collected (total of 1.2 mL) then analyzed by HPLC- CLND and UV detection. Aqueous ethylene thiourea standard solutions were used for calibrating the CLND response. Linearity of HPLC-CLND is shown in Figure 4.8. Linear regression analysis (r=0.99990; m=0.01983; b=- 0.59071) was calculated where r = correlation coefficient, m = slope, and b = y-intercept. The minimum detectable limit (MDL) of the CLND is 3 ng of

Page 457: Instrumental

440

ETU Compound (10 mg + 1 mL)

I No

I

I soluble in water?

i I

No

3-A

Yes I I _ " " =" " I

soluble in methanol?

I I

I I I I I I I w No

' l ' ( 3 _ A ) I I I I 2 - B I ' 1 - F I L . . . . I

Yes i I

" 1 " " J

soluble in methylene - - - - chloride?

Yes

I soluble in

- ' - - " hexane? "--'--

No Yes

I I 3-A 3-A 2-C 1 -I 1-H

Figure 4.6 Method development flow chart for solid phase extraction where condition selection is based on compound solubility (3-A: SCX, SAX, CN, or NH 2. Reprinted from The Supelco Guide to Solid Phase Extraction, with permission.

Page 458: Instrumental

441

Apple Juice (fortified with 10 ppm E-IU)

SPEC-47-C18AR MICROCOLUMN

(47 mm disc)

Aqueous Juice Fraction

SPEC VC MP3 MICROCOLUMN

(PP, 15 rag) PHASE

I .

VACUUM C8

- ~ C18 S A M P L E

~F.se~ C18AR

SCX

L._~ ~'~ SAX ~.SEFW~R~ CN

L ~ r NH2 " ~ sxn=JmTmN 1 ~ o ~ c Si

or .ocor~ MP1

PSA MP3

HPLC-CLND analysis Figure 4.7 SPEC Microcolumn solid phase extraction (SPEC

Division ANSYS, Inc.) and HPLC-CLND (Antek Instruments, Inc).

Page 459: Instrumental

442

R e 8.6 S

P o 0,4

S

e 8.2

4 18 0.8

8.8

..... j

/ ,

.

/

/

j /v

/ //"

.!.. ...:

i... , r

!

58.8 i ,, [

188.8 Concentration

Figure 4.8 L~FU s t a n d a r d cu rve by HPLC-CLND.

8.11~

V

0

i tB.l~ S

B.M

ZTU

~om I~1 ' 1 Depth ' I

8.1111 5.~ 18.~ 15.88

Figure 4.9 MDL of ETU by HPLC-CLND: 6pL x 0 .5ng /pL ETU.

Page 460: Instrumental

443

a. 6~L x 1 ppm ETU standard. b. 6~L x 2 ppm ETU standard. c. 6gL x 10 ppm ETU standard. d. 6~L x 20 ppm ETU standard.

I l

0 5 Time (min)

a) : i . . . . . . . i i

10 0 5 10 Time (min)

b)

~ - " ~ - - - - ~ - ~ c) r - - - C ~ I - - . . . . . . i . . . . . I i . . . . . . . I '

0 5 10 0 5 10 Time (rain) Time (rain)

d)

Figure 4.10 HPLC-CLND chromatograms of ETU s tandards in water.

Page 461: Instrumental

444

ETU on-column (61aL x 0.5 ppm ETU or 0.816 ng N, with S/N ratio of 2/1) and presented in Figure 4.9. HPLC-CLND chromatograms of the ETU standards at 1, 2, 10, and 20 ppm concentrations are shown in Figure 4.10.

Figure 4.11 is the HPLC-CLND chromatogram of the 100 mL recovery apple juice sample containing 10 ppm of ETU after extraction with the 47 mm (diameter) disc with a C18AR solid phase. ETU peak is on the shoulder of a large nitrogen containing component. It is clear that additional cleanup of the juice matrix is necessary, therefore 1 mL of this aqueous juice fraction was placed on a MP3 microcolumn (second SPE clean-up step) and eluted with 0.5 mL of 3% acetic acid methanol/water (50:50 v/v) solution. Analysis of the 10 ppm ETU recovery sample shows a significant cleanup (Figure 4.12c) as compared to the first cleanup step (Figure 4.11). The apple juice control sample is shown in Figure 4.12b. A water solvent blank showing the baseline after the MP3 solid phase extraction is presented in Figure 4.12a. HPLC with UV detection at 240 nm of the control (no ETU) apple juice through only the first clean-up step is shown in Figure 4.13a. Recovery sample with 10 ppm ETU after the first and second SPE clean-up is provided in Figures 4.13b and 4.13c, respectively. A side by side comparison of the apple juice ETU recovery sample analyzed by HPLC-CLND and UV detection is shown in Figure 4.14. Apple juice ETU recovery sample #2 analyzed by HPLC-CLND calculated to 74.8% and UV detection (72%) agreed within 3.7% as depicted by Table 4.1.

Page 462: Instrumental

445

y

_0

b"

O

< !

I--.. !

.=

~3

�9

,.d ~.) 6~ ,.d

~

Page 463: Instrumental

446

_o

L _0

[--,

-O

b I::I

r

~:ro <~~.~

_0

-11r

-0

ow,,,,,~

I=I

0o r-,-I

I::I o

o.,! r o

~

Z r,..) ! rj~ ,.~ u-I

,,,,,,,,,i

Page 464: Instrumental

447

":~ -

t.r

..0

o~,,,,q

-0

..0 0

t~

\

_0

o~,,,q

" tr ~

[--

-0

< oo !

o1,,~

~

ol-.,q

E.-

o o

0 > f12

OJO ol--,q 8 0

v ~o

2. s rj >

Page 465: Instrumental

448 5o

~4

-Ir [-..

-f,,~

�9 --

0

~

t~

o "tJ ,-:,

>~:

~-~ C

~,. z~

O~

Page 466: Instrumental

449

Table 4.1

HPLC-CLND analysis of ETU recoveries in apple juice after two different microcolumn solid phase extractions performed in series.

Apple juice

ErU Sample Integration ETU ETU standard size of

ppm laL peak area ng % recovery

0.5 6 146 3 1.0 6 362 6 2.0 6 617 12 10.0 6 3102 60 20.0 6 6059 120

Recovery #1, CLND 6 Recovery #2, CLND 6

2160 42.24 70.4 2294 44.90 74.8

Recovery #2, UV 6 1,796 43.20 72.0

The average recovery of the two samples analyzed by CLND calculated to be 72.6%. The utility of HPLC-CLND and the SPEC Microcolumn solid phase extraction can provide a quick scouting approach at the beginning of a method development process. A volume of 100 mL apple juice sample was easily extracted on the 47 mm SPEC Microcolumn disc. The HPLC-CLND sensitivity of 3 ng ETU on-column was observed in this study.

4.4 HPLC-CLND: African type Capsicum Oleoresin

The hot flavors in many foods are often due to the presence of capsaicinoids, a class of nitrogen containing compounds. The means to obtain a standardized method to measure the heat levels in foods is essential. A clean-up method reported by Cooper was used [4.4]. The solid phase extraction was scaled down to 100 mg of silica prior to HPLC and the new nitrogen detection technique described herein. HPLC-CLND application of capsicum oleoresin is presented in Figure 4.15. The elution order of the capsaicinoids are as follows: A=nordihydrocapsaicin, B=capsaicin, and

Page 467: Instrumental

450

I ' ' l i . . . . I 0 20 40 60

Time (min)

Figure 4.15 HPLC-CLND of African type capsicum oleoresin. Peaks: A=nordihydrocapsaicin, B=capsaicin, and C=dihydrocapsaicin.

Page 468: Instrumental

451

C=dihydrocapsaicin. Capsaicin and dihydrocapsaicin have been quantitated in red hot peppers by HPLC-CLND [4.5].

Chromatographic Conditions Capsicum oleoresin (20 mg) was extracted from the Supelclean LC-Si 1

mL (100 mg) SPE tube using 2 x 1 mL methanol elution and analyzed by HPLC-CLND. LC-Si bed was activated with 1 mL hexane. The oleoresin was directly weighed into the tube, solid phase was washed with 2 x 1 mL hexane before extracting with methanol. A 20 9L loop injection was made to a SUPELCOSIL LC-18S column: 250mm x 4.6mm ID, 5 lam particle size, 100A pore size. An isocratic mobile phase (MP) methanol/water (60/40 v/v) with 0.1% citric acid (pH 3.0) mixture was utilized with a flow rate of 650 taL/min. A post-column split was used with a flow rate of 200 ~tL/min to the CLND and 450 9L/min to waste. The CLND conditions: 1050 ~ C pyrolysis temperature, PMT voltage 760, range x 10, and detector output 1 volt.

4.5 HPLC-CLND: Aspartame and Nitrogen Compounds in Beverages

Aspartame, scientifically known as L-aspartyl-L-phenylalanine methyl ester, can be readily detected and quantitated by HPLC-CLND. A simultaneous HPLC-CLND and UV (214 nm) detection of aspartame and other nitrogenous compounds in diet soft drinks have been reported [4.6]. Dual detection was performed with a post-column split as shown in Figure 4.3. Diet cola samples #3, #4 (caffeine free), and #5 will be reviewed in Figures 4.16, 4.17, and 4.18, respectively. Table 4.2 provides the quantitative results by CLND of aspartame levels found for these three diet cola and citrus beverages. Each CLND profile (Figures 4.16, 4.17, and 4.18) is different. In particular, diet cola #5 has a large unidentified peak A (a nitrogen containing component) and a low aspartame level (90 ppm) as compared to diet colas #3 and #4. Sodium benzoate does not contain nitrogen and is not observed by the CLND. Because sodium benzoate contains an aromatic chromophore, it is easily observed by UV detection. Sample profiles obtained by simultaneous detection can save time and provide useful sample information. DKP, a decomposition product of aspartame, was also observed using this detection technique [4.6]. HPLC-CLND analysis of caffeine in coffee and other beverages has been reported [4.7].

Page 469: Instrumental

452

I \ B

! !

0 8 16

A=saccharin B=caffeine C=aspartame D=sodium benzoate (no nitrogen in D)

HPLC-CLND

UV

Time (min) Figure 4.16 Simultaneous HPLC-CLND and UV (214 nm)

detection of diet cola sample #3. Reprinted from E. M. Fujinari, G. Charalambous

(Ed.), Shelf Life Studies of Foods and Beverages, Elsevier Science Publishers, Amsterdam, (1993) 1033, with permission.

Page 470: Instrumental

453

n' I

A C 9

i_ | - - ' ,

0 8 16

A=saccharin (caffeine free) C=aspartame D=sodium benzoate (no nitrogen in D)

HPLC-CLND

UV

Time (min) Figure 4.17 Simultaneous HPLC-CLND and UV (214 nm)

detection of diet cola sample #4 (caffeine free). Reprinted from E. M. Fujinari, G. Charalambous (Ed.), Shelf Life Studies of Foods and Beverages, Elsevier Science Publishers, Amsterdam, (1993) 1033, with permission.

Page 471: Instrumental

454

c

0

| !

0 8 16 Time (min)

A=N-compound B=saccharin C-caffeine D=aspartame E=sodium benzoate (no nitrogen in D)

HPLC-CLND

UV

Figure 4.18 Simultaneous HPLC-CLND and UV (214 nm) detection of diet cola sample #5. Reprinted from E. M. Fujinari, G. Charalambous

(Ed.), Shelf Life Studies of Foods and Beverages, Elsevier Science Publishers, Amsterdam, (1993) 103 3, with permission.

Page 472: Instrumental

455

Table 4.2

HPLC-CLND analysis of aspartame in diet soft drink beverages.

Diet Aspartame Sample Integration Aspartame Aspartame beverage standard size of or brand ppm ~L peak area lag ppm

50 5 4808 0.250 100 5 10027 0.500 200 5 20772 1.000 400 5 42182 2.000

Citrus # 1 5 43428 2.059 412 Citrus #2 5 44051 2.088 418 Cola #3 5 50918 2.409 482 Cola #4 5 46399 2.198 440 Cola #5 5 9044 0.451 90

Reprinted from E. M. Fujinari, "Shelf Life Studies of Foods and Beverages", G. Chara lambous Ecl., Elsevier Science Publishers, Amsterdam, (1993) 1033, with permission.

Chromatographic Conditions A 50 lxL loop injection was made to a Deltabond ODS column: 150mm

x 4.6mm ID, 5 ~m particle size, 300A pore size. An isocratic mobile phase (82/18 v/v) mixture: aqueous solution containing 0.2% H3PO 4 at pH 2.2 (with 0.05M KH2PO4/methanol was utilized with a flow rate of 1 mL/min. A post- column split was used with a flow rate of 0.450 mL/min to the CLND and0.550 mL/min to the UV (214 nm) detector. The CLND conditions: 1050~ pyrolysis temperature, PMT voltage 700, range x25, and detector output 1 volt.

4.6 HPLC-CLND: Important Biochemicals and Food Components

A preliminary study for a direct detection of biochemicals such as amino acids, peptides, and proteins by HPLC-CLND without pre- or post- column derivatization has been reported [4.8]. Since nature's own biochemical processes have provided a nitrogen label on each of these classes

Page 473: Instrumental

456

of compounds, the use of a nitrogen detector such as the CLND is inherently suitable. A reversed phase HPLC peptide mapping with UV (214 nm) detection and a peptide mapping based on 'nitrogen content' detection using HPLC-CLND of peptides isolated from casein hydrolysate were reported earlier [4.1 ]. The advantage of simultaneous peptide mapping technique using CLND/UV detection is presented in Figure 4.19. Peak A is a peptide with no aromatic UV chromophore and appears as a minor component by UV detection. Peak B is a peptide which contains aromatic UV chromophores (4 Tyrosines) and consequently showed a strong UV response. It was determined by the CLND that peptide A contained a greater nitrogen content than peptide B. Results of the amino acid analysis for peptides A and B are discussed in detail [4.1 ].

Nucleotides, nucleosides, and their corresponding bases (pyrimidines and purines) are hydrolysis products of nucleic acids, such as DNA and RNA. Figure 4.20 shows HPLC-CLND chromatogram of an aqueous standard mixture consisting of 5 nucleotides, 6 nucleosides, and orotic acid. The aqueous standard mixture of their corresponding bases, purines and pyrimidines, have also been detected by HPLC-CLND as depicted in Figure 4.21 [4.9]. These important biomolecules play a paramount role in foods and flavors, in biochemical processes, and in pharmaceutical and related industries.

Monosodium glutamate (MSG) is the monosodium derivative of an

H HO zCCHzCH zC OOzNa ~

NHz

MSG

amino acid, L-glutamic acid. MSG, like L-glutamic acid, does not contain aromatic UV chromophore and may have difficulties with the sample matrix or baseline interference(s) when using the UV detector. However, a quick and easy determination of MSG in various types of soup bases have been recently accomplished using a nitrogen-specific detector, HPLC-CLND [4.10]. Results of the MSG quantitation in various soup bases are presented in Table 4.3. The HPLC-CLND chromatograms of MSG in some different soup bases are shown in Figure 4.22.

Page 474: Instrumental

457

UV (k = 214nm)

B

. . . . . . . . . . .

i - 10 20 30 4~0 time (rain)

CLND

7--- 6

A

B

' I . . . . .to 20 3~ Time (min)

Figure 4.19 RP-HPLC chromatograms of casein hydrolysate. Peaks: A=peptide with no aromatic UV chromophore, B=peptide with aromatic UV chromophore. Reprinted from E. M. Fujinari and J. D. Manes, J. Chromatogr. A, 676 (1994) 113, with permission.

Page 475: Instrumental

458

A = Adenosine C = Cytidine

|

O r o ~ i c acid

~ / /h~P+Ur I dine

IMP ~/ Inosine Guan Thymidine

CHP GHP~

" �9 ~ ~

' ' ' ' ' ) ' ' ' ' l

0 10 20

Time (min)

Figure 4.20 HPLC-CLND Chromatogram of a s tandard mixture consisting of 5 nucleotides (5'-substituents), 6 nucleosides, and orotic acid in aqueous solution. Reprinted from E. M. Fujinari and J. D. Manes, G. Charalambous (Ed.), Food Flavors: Generation, Analysis and Process Influence, Elsevier Science Publishers, Amsterdam, (1995) 379, with permission.

Page 476: Instrumental

459

1 = Cytosine 2 = Uracil 3 = Guan ine 4 = S-Methyl cy tos ine 5 = Xanth ine 6 = T h y m i n e 7 = Aden ine

4

1

2 3 5 6 7

' ' 1 ' ' ' ' I

10 20

Time (min)

Figure 4.21 HPLC-CLND C h r o m a t o g r a m of a s t a n d a r d mix ture consis t ing of the c o r r e s p o n d i n g pu r ine a n d py r imid ine bases of the nuc leo t ides a n d nucleos ides in a q u e o u s solution. Repr in ted f rom E. M. Fujinari a n d J. D. Manes, G. C h a r a l a m b o u s (Ecl.), Food Flavors: Genera t ion , Analysis a n d Process Influence, Elsevier Science Publishers, Ams te rdam, (1995) 379, with permiss ion.

Page 477: Instrumental

460

0 >

LL

�9

0 >

It_ Q..

E

I,...

u?

%

(_9 O

9 "x ___J L _0

I- o..,~

-~ E

-,~'E

.m

-04

-0 Q

r. ,

,N

-~E

v

-Cxl

-0

L.

0 >

u_ ,.---.

. ,,,,..

0 E

0 0 c, ~9

1--

0 ~ ..C

0

S

_O

r-

-~ E

v

-~tE

~

-CXl

-0

0

r-

-~E

v

-~t E

~-o

..~

o o

.w.,,!

o E

t~

0 E

o

Z 0 -1

fxl

o...i

Page 478: Instrumental

461

Table 4.3

HPLC-CLND analysis of MSG in flavored soup bases.

Soup MSG std Sample Integration of MSG flavor ppm size (taL) peak area (xl03) ng (xl03)

MSG ppm

500 2 0.815 1 1,000 2 1.668 2 2,500 2 4.880 5 5,000 2 8.997 10

Chicken 2 4.358 4.791 Chicken & Mushroom 2 6.738 Shrimp 2 5.548 6.085 Beef 2 4.632 5.089 Oriental 2 6.020 6.599

2,3% 7.379 3,043 2,545 3,300

Chromatographic Conditions A 2 ~L partial filled (5 laL loop) injection was made to a Hamilton

PRP-X100 column (Keystone Scientific Inc.): 50mm x 3mm ID, 10 ~tm particle size. An isocratic mobile phase (MP) methanol/water (80/20 v/v) with 0.1M citric acid (pH 2.6) mixture was utilized with a flow rate of 500 laL/min. A post-column split was used with a flow rate of 100 laL/min to the CLND and 400 laL/min to waste. The HPLC-CLND (Antek Instruments Inc.) conditions: 1050 ~ C pyrolysis temperature, PMT voltage 760, range x50, and detector output 1 volt.

4.7 SEC-CLND: Size Exclusion Chromatography (SEC) of Peptides and Food Grade Protein Hydrolysates

A chemiluminescent nitrogen detector (CLND) with size exclusion chromatography (SEC) was developed to estimate average molecular weight distribution of peptides and food grade protein hydrolysates, as well as protein hydrolysate-based foods [4.11 ]. SEC separations of the 7 component standard mixture was achieved from 30000 to 75 dalton range using a silica based TSK-G2000SWXL column (Figure 4.23). The SEC calibration for this

Page 479: Instrumental

462

M w

29000 = carbonic anhydrase 14400 = a- lactalbumin 3550 = insulin 1620 = bombesin

777 = neuro tens in (1-?) 425 =/~-casomorphin (1-3) 204 = t ryp tophan

CLND

I~" I.~ I~ ~1 t-- ~t"

O O O

~ s o a c,4

c,4

o

2 o

uV o

I I . . . . . . I . . . . I I

0 7.5 15 18.5 30

Time (min)

Figure 4.23 Size exclusion ch roma tog raphy with TSK- G2000SWXL column of 7 componen t s tandard mixture, s imul taneous CLND and UV

(214 nm) detection. Reprinted from E. M. Fujinari and J. D. Manes, G. Chara lambous (Ed.), Food Flavors: Generation, Analysis and Process Influence, Elsevier Science Publishers, Amsterdam, (1995) 929, with permission

Page 480: Instrumental

463

column (the molecular weight distribution of the seven standards over the separation time) is presented in Figure 4.24. Response factors ( f = l ) relative to bombesin were calculated for ct-lactalbumin, a milk protein (Mw - 14400 dalton), bombesin, a bioactive peptide (Mw = 1620 dalton), and the smallest peptide, glycyl-glycine (Mw - 132 dalton), indicating equimolar nitrogen responses for the CLND. One example to highlight the advantage of using a dual detection system for SEC will be reviewed. A simultaneous CLND and UV (214 nm) detection was used to analyze an extensively hydrolyzed casein (22.0 ~tg) by SEC (Figure 4.25). The manufacturer of this product reported approximately 50% degree of hydrolysis with 50% free amino acid content. The results obtained from the dual detection technique provided an inherently different Mw profile. The UV profile indicated a minor component (Mw=680 daltons) as a shoulder to the major peptide with average Mw=334 D. The CLND however, revealed this peptide (average Mw=680 D) as the third major component in the casein hydrolysate. This major component (average Mw=680 D) in the sample did not contain a significant UV chromophore as depicted in the UV chromatogram. The advantage of using the CLND is that (on-line) nitrogen content measurement can be obtained for each sample component, as they elute from the chromatographic column. The CLND also showed the two major components (as UV detection), peptide average Mw=275 D, and the free amino acids Mw-108 D. We demonstrated a very powerful technique, i.e. dual CLND/UV detection for S EC and a better means to characterize food grade protein hydrolysates, peptides, and amino acids than by stand-alone UV detection.

Page 481: Instrumental

464

M W

29000 = carbonic anhydrase 14400 = a- lactalbumin 3 5 5 0 = insulin 1620 = bombesin

777 = neuro tens in (1-7) 425 = ~-casomorphin (1-3) 204 = t ryp tophan

0 1

4.8

4.4

4.2

' r L3 ~U 3.s L_

3.4

I 7

13 14 15 16 17 18 19 29 21 22 23 24 25

~ 1]~ MINLrFE5

[] EXPT D A T A - I ~ VALUF~

Figure 4.24 Molecular weight cal ibrat ion by SEC with TSK- G2000SWXL column of 7 componen t s tandard mixture, Detector:. CLND. Reprinted from E. M. Fujinari and J. D. Manes, G. Chara lambous (Ed.), Food Flavors: Generation, Analysis and Process Influence, Elsevier Science Publishers, Amsterdam, (1995) 929, with permission

Page 482: Instrumental

4 6 5

CLND

uv

[ . . . .

o 6

O ~ oo oo I'~ O ~D c,.l ,-~

~D oo 0

,q

o o

- i t - ' ~ ' - - - Ai - _ . . . . . 1 . . . . . . . . . . i

1'2 18 2 4

Time (min)

Figure 4.25 Size exclusion chromatography with TSK- G2000SWXL column of extensively hydrolyzed casein with simultaneous CLND and UV (214 rim) detection. Reprinted from E. M. Fujinari and J. D. Manes, G. Charalambous (Ed.), Food Flavors: Generation, Analysis and Process Influence, Elsevier Science Publishers, Amsterdam, (1995) 929, with permission.

Page 483: Instrumental

466

4. REFERENCES

4.1 E.M. Fujinari and J. D. Manes, J. Chromatogr. A, 676 (1994) 113. 4.2 E.M. Fujinari and L. O. Courthaudon, J. Chromatogr., 592 (1992) 209. 4.3 E.M. Fujinari, presented at the 206th ACS National Meeting, Residue

Analytical Methods and Emerging Technologies II Session, Chicago, IL, August 22-27, unpublished.

4.4 T.H. Cooper, J. A. Guzinski, and C. Fisher, J. Agric. Food Chem., 39 (1991) 2253.

4.5 E.M. Fujinari, "Spices, Herbs and Edible Fungi", G. Charlambous Ed., Elsevier Science Publishers, Amsterdam, (1994) 367.

4.6 E. M. Fujinari, "Shelf Life Studies of Foods and Beverages", G. Charlambous Ed., Elsevier Science Publishers, Amsterdam, (1993) 1033.

4.7 E. M. Fujinari, in "Food Flavors, Ingredients and Composition", G. Charlambous (Ed.), Elsevier Science Publishers, Amsterdam, (1993) 55.

4.8 E. M. Fujinari, E. Ribble, and M. V. Piserchio in "Food Flavors, Ingredients and Composition", G. Charlambous (Ed.), Elsevier Science Publishers, Amsterdam, (1993) 75.

4.9 E.M. Fujinari and J. D. Manes, "Food Flavors: Generation, Analysis and Process Influence", G. Charlambous Ed., Elsevier Science Publishers, Amsterdam, (1995) 379. E. M. Fujinari and E. Ribble-Garlick, presented at the 1995 Pittsburgh Conference, Liquid Chromatography - Food Analysis Session, New Orleans, LA, March 5-10, 1995. E. M. Fujinari and J. D. Manes, "Food Flavors: Generation, Analysis and Process Influence", G. Charlambous Ed., Elsevier Science Publishers, Amsterdam, (1995) 929.

4.10

4.11

Page 484: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 467

5 The Determination of Compositional and Molecular Weight Distributions of Cationic Polymers Using Chemiluminescent Nitrogen Detection (CLND) in Aqueous Size Exclusion Chromatography

Frank J. Kolpak a *, James E. Brady a, and Eugene M. Fujinari b

aHercules Inc., Research Center, 500 Hercules Road, Wilmington, DE 19808 U.S.A.

bAntek Instruments Inc., 300 Bammel Wesffield Road, Houston, Texas 77090 U.S.A.

5.1 INTRODUCTION

Differential refractive index (DRI) is the most common means of mass detection for the molecular weight distribution analysis of polymers by size exclusion chromatography (SEC). For aqueous SEC mobile phases comprised of simple salts or buffers, this detection strategy is usually adequate except for the presence of a system or buffer peak at moderately long retention times, which may interfere with detection of the low moleular weight end of the distribution. For polymers containing a chromophore, UV detection is an improvement. The direct determination of nitrogen in liquid chromatographic eluents by a chemiluminescent nitrogen detector (CLND), now affords a potentially more sensitive means of characterizing nitrogen based cationic polymers by SEC. This approach also allows for the use of a greater selection of mobile phase compositions than the simple buffer or salt solutions (i.e. aqueous/organic mobile phases) because the system peak is transparent to the element specific nature of CLND. Chemiluminescent nitrogen detection is shown to be a viable, and potentially powerful, means of characterizing polymeric materials.

Page 485: Instrumental

468

5.2 EXPERIMENTAL

Apparatus Aqueous size exclusion chromatographic (SEC) separations were

achieved using a Waters 510 solvent delivery system and a Waters WISP.717 autoinjector (Milford, MA). A stainless steel T-splitter from Valco Instruments Co. Inc. (Houston, TX) was used to achieve dual DRI/CLND detection. Synchrom CATSEC columns which contain cationically modified silica porous packing material, were purchased from Keystone Scientific Inc. (Bellefonte, PA). The primary (mass) detection of cationic polymers was accomplished with a Hewlett-Packard (Wilmington, DE) 1047A differential refractometer. Nitrogen specific detection of the SEC eluent was accomplished with a chemiluminescent nitrogen detector model 7000 HPLC- CLND from Antek Instruments Inc. (Houston, TX). Data collection was accomplished with the Waters ExpertEase data acquisition and analysis software run on a VAXstation 3100.

Reagents and Standards The 20K, 250K, 350K, and 6,000K poly(acrylamide) standards were

purchased from American Polymer Standards (Mentor, OH). House distilled water was used to prepare the mobile phase. Glacial acetic acid, lithium chloride and ethylene glycol reagents were purchased from Aldrich Chemical (Milwaukee, WI). All standards and reagents were used without further purification. The SEC mobile phase was 0.20M Li acetate plus 2% ethylene glycol (pH 4.5). It was filtered through a Rainin Instruments Inc. (Woburn, MA) Nylon-66 0.22 lam pore size filter. The internal flow standard was acetic acid.

Standards and Analytical methods The poly(acrylamide) standards were dissolved at a concentration of 2

mg/mL in the mobile phase and injected without further preparation. The cationic resin was dissolved at the same concentration in mobile phase and filtered through a 0.45 ~tm PVDF membrane (Millipore Millex-HV - Marborough, MA) prior to injection. Sample and standard injections were 50tttL and mobile phase flow rate was 0.25 mL/min. The columns were CATSEC 4000A + 1000A + 300A + 100A in series. The temperature of the columns and the DRI detector were thermostatted to 40~ The flow was split 50:50 to the DRI and CLND detectors after exiting the columns. The CLND conditions were: 1050~ pyrolysis temperature, PMT voltage 650, range x50, and detector output 1 volt. A schematic flow diagram for the DRI/CLND dual detection SEC system is shown in Figure 5.1.

Page 486: Instrumental

469

ao

Z

o

__

10

ll,,i, 0

a

r-

E

r

oE

�9

Z o J0 ~ �9

~ < t~

~

Page 487: Instrumental

470

5.3 RESULTS AND DISCUSSION

An example of the DRI/CLND dual detection SEC analysis that can be performed is shown in Figure 5.2. In this plot, the DRI and CLND signals are not adjusted for registration differences. However, it is clear that the chromatographic envelopes for the two signals are essentially the same, which would be expected for a homopolymer. The significant system peaks in the DRI chromatogram (31.3 and 32.6 min) are virtually absent in the CLND chromatogram, indicating that they are not due to the standard. Figure 5.3 shows the CLND chromatograms of three poly(acrylamide) standards with order of magnitude increments in molecular weight. This plot demonstrates the ability of the CLND to handle very high molecular weight polymers as readily as low molecular weight ones.

In Figure 5.4, the dual SEC analysis of a chain extended polyamine is shown. The polymer exhibits a bimodal molecular weight distribution due to the chain extension step, which is accomplished with a nitrogen free reagent. For a sample which is not a linear homopolymer, an analysis such as this can provide chemical composition data as a function of the molecular weight distribution. This approach can be particularly valuable in analyzing off-spec material. The DRI/CLND S EC analysis can detect differences between two lots of polymer which have similar molecular weight distributions, but dissimilar chemical composition distributions. Such subtle, but previously undetectable, discrepancies could account for noticeable performance variation between the resins.

5. REFERENCES

5.1 F. J. Kolpak, J. E. Brady, and E. M. Fujinari, presented at the 18th International Symposium On Column Liquid Chromatography, HPLC'94, Polymer Analysis and Characterization Session, Minneapolis, MN, May 8-13, 1994.

Page 488: Instrumental

471

o !

0 m

~ j

~ _~

~I j1

Z

~

J

~-

r 4)

"

<(

_o

,q.

�9 o'J

-0 2 ,

E

E

_~1"-

6 U.I U

)

�9

E ~

o,...q

E �9

�9

�9

E

.o x s o

,.~

t~ d

Page 489: Instrumental

472

u~

c~

I

0

o o o ~G <

I I

I I

I

U3

O

t~

O

U3

O

04 od

,-: ,-:

c5 c5

(AUJ) esuodseH JoloeloCI ClN-IO

0 0 0 -

u,i

O~

-

d~

v E V

-

0

-~iii

0 0 0

0 !

~o

o ~

0

0 0 o,...4

~

e~

t~

0 ~g

0

.~ -~.

X

N

m~

m

Page 490: Instrumental

473

r'1 Z _J (9

I::: 0 ~ I:::

I::: ~ .,..,,

ltl J::

.I::: .,.,,,,

I

0 e,i

rr

| ~--

! -

'r- 0

(AUJ) osuodsoEl JOlOO]O(]

0 0 ~t 0

0 ~

t-

O

0 !

0 co

O~

c~ v E ~ l- c 0

,...,

0 :~

cJ

0 C~ cq

~ �9

�9

C~ Z .-I

C~

~ �9

o .o N ~ t~

.,,.-i

Page 491: Instrumental

This Page Intentionally Left Blank

Page 492: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 475

6

Chemiluminescent Nitrogen Detection in Capillary SFC

Heng. Shi a, J. Thompson. B. Strode III a, Larry T. Taylor a * and Eugene M. Fujinari b

aDepartment of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24060 U.S.A.

bAntek Instruments Inc., 300 Bammel Westfield Road, Houston, Texas 77090 U.S.A.

6.1 INTRODUCTION

Chemiluminescence detectors have become increasingly important in the analytical world because of their inherent advantages in chromatographic detection, i.e. extremely high element-selectivity and sensitivity. Applications with the nitric oxide/ozone based chemiluminescent nitrogen detector (CLND) for GC have been reported earlier [6.1-6.2]. Benn et al. showed detailed examples for (GC-CLND) detection of nitrogen containing components in flavors and essential oils [6.3]. CLND for HPLC was first described for the detection of ammonium nitrogen in waste water [6.4]. Many examples for nitrogen-specific (CLND) detection of various nitrogen- containing compounds in complex sample matrices have been shown in the earlier sections (Parts 1 -5).

The CLND was sucessfully interfaced for the first time to capillary S FC and studied extensively in terms of detector optimization under supercritical fluid conditions 1) without a column for flow injection analysis and 2) for capillary chromatography. More recently, new pharmaceutical applications are reported where polar nitrogen containing compounds are eluted from packed column SFC with methanol modified CO2 and detected using the CLND [6.5]. S FC-CLND has opened a new dimension in analytical chemistry. Its intrinsic use in the nitrogen-specific detection mode is presented for analysis of horseradish oil and other nitrogen containing compounds. Applications with the novel simultaneous CLND/FID for capillary S FC are also discussed.

Page 493: Instrumental

476

6.2 EXPERIMENTAL

Apparatus A model 705D CLND nitrogen specific detector from Antek

Instruments (Houston, TX, U.S.A.) was interfaced to either a Hewlett-Packard (Wilmington, DE, U.S.A.) 1250A supercritical fluid chromatograph (for flow injection analysis) or a Dionex Lee Scientific (Salt Lake City, UT, U.S.A.) series 600 SFC (for chromatographic separation). SB-cyanopropyl capillary column (20 m x 100 lam I.D., 0.25 ~xm film thickness) from Dionex and a DB- 1701 (10 m x 100 ~m I.D., 0.4 ~tm film thickness) column from J & W Scientific (Folsom, CA, U.S.A.) were utilized in this study. A 25 lam I.D. Integral restrictor was used with the DB-1701 capillary column and a 50 ~m I.D.Frit restrictor was used with the SB-cyanopropyl capillary column. Time split injector from Valco (Houston, TX, U.S.A.) was used with a 500 nL rotor. A Hewlett-Packard 3310 integrator was used for data acquisition.

Reagents and Standards Allyl cyanide, allylisothiocyanate, 2,3-dimethylindole, 2,6-

dinitrotoluene, diphenylamine, indole, 4-nitrotoluene, 2-phenylindole, phenyl ethyl isothiocyanate, and pyridine were purchased from Aldrich (Miliwaukee, WI, U.S.A.). p-Nitroaniline was purchased from Fisher Scientific (Pittsburgh, PA, U.S.A.). Caffeine was purchased from Sigma Chemical (St. Louis, MO, U.S.A.), 2,5-1utidine from Chem Service Inc. (West Chester, PA, U.S.A), 2- butyl isothiocyanate from Lancaster Synthesis Inc. (Windham, NH, U.S.A.), and dimethoate from Accu Standard Inc. (New Haven, CT, U.S.A.). Alkyldimethylamine mixture was obtained from Albemarle Corporation (Baton Rouge, LA, U.S.A.). All chemicals were used without further purification. Horseradish oil standard, Wasabi and the hot yellow mustard were received from commercial sources and extracted into methanol. HPLC grade solvents from EM Science (Gibbstown, NJ, U.S.A.) were used for preparing standard solutions. Grade 4.3 oxygen from Airco (Murry Hill, NJ, U.S.A.) was used as both pyrolysis and ozone-generator gas. SFC-grade CO2 was obtained from Air Products and Chemical Inc. (Allentown, PA, U.S.A.).

Chromatographic Conditions All analyses were performed with pressure programming. In all cases,

the oven temperature was held constant throughout the run. Integrator conditions: 1 volt input, attenuation 7. CLND conditions: pyrolysis temperature 1050 ~ PMT voltage 750, range x50, detector output 1 volt. FID conditions: 360 mL/min air, 65 mL/min hydrogen, 34 mL/min nitrogen

Page 494: Instrumental

477

(make-up gas), 1 volt output, and detector temperature was 350~ Additional chromatographic conditions are cited in the Figure legends.

6.3 RESULTS AND DISCUSSION

The first successful interface between the chemi|uminescent nitrogen detector (CLND) and capillary SFC systems was accomplished. Frit and Integral restrictors were used and positioned at the bottom of the cylindrical burner of the CLND as shown in Figure 6.1. In optimizing the detector, several effects such as restrictor position, and pyroreactor oxygen flow rate have been investigated by flow injection analysis (FIA) using the Hewlett- Packard SFC system. It was found that the restrictor position (of 15 cm from the base of the nut to the restrictor tip) was critical to the detector performance. The response factor relative to indole for several nitrogen containing compounds has been measured by the CLND under S F conditions without a column and are listed in Table 6.1. Results indicated an equimolar

Table 6.1

Response Factors ( f ) relative to indole with CLND and 100% CO 2 supercritical fluid conditions

Compound (fx)/N

caffeine 1.07 3,3-dimethylindole 1.04 2,6-di nitrotol uene 1.05 diphenylamine 1.06 indole 1 4-nitrotoluene 1.01 2-phenylindole 1.01 pyridine 1.01

nitrogen response by the detector. The limit of detection of 60 pg of nitrogen was determined in 100% CO2 mobile phase. Detector linearity was found to

Page 495: Instrumental

478

to reaction chamber

, , ! ..... d oxygen

frit restrictor I

pyrolysis tube

! ---= ;:--. : .11 i - - - ~ . . . . .

/

15 cm

l column effluent

Figure 6.1 Schematic illustrating the interface between the supercritical fluid chromatography (SFC) system and chemiluminescent nitrogen detector (CLND). A frit or integral restrictor (from the exit end of the capillary column) is placed at the base of the CLND pyro-furnace to achieve best oxidation and pyrolysis of the sample eluent. Chemiluminescence takes place in the reaction chamber of the detector. Reprinted from H. Shi, J. T. B. Strode III, L. T. Taylor*, and E. M. Fujinari, J. Chromatogr. A, 734 (1996) 303 with permission.

Page 496: Instrumental

479

be at least three orders of magnitude at a single range setting. A selectivity (N/C) of 107 was obtained.

The CLND was then coupled to the Series 600 Lee Scientific SFC system using S B-cyanopropyl and DB-1701 capillary columns for chromatographic separation and subsequent nitrogen-specific detection. Figure 6.2 shows structures of the 5 nitrogen containing components found in horseradish oil standard. SFC-CLND chromatogram of the horseradish oil is profiled in Figure 6.3. Levels of horseradish oil in foods for flavor assessments are typically quantitated by measuring the allyisothiocyanate component (peak C). In addition to the unidentified peak C, the CLND chromatogram of the hot yellow mustard (Figure 6.4) showed two compounds (peaks:A=allyisothiocyanate and B=2-butylisothiocyanate) which are also present in the horseradish oil. Figure 6.5 shows the SFC separation and CLND detection of 7 nitrogen containing compounds, including caffeine (food and beverage ingredient) and dimethoate (insecticide), peaks 4 and 6, respectively.

Simultaneous UV and sulfur chemiluminescence detector (SCD, Sievers Instruments Inc., Boulder, CO, U.S.A.) has been previously interfaced to SFC by Howard et al. [6.6]. Bornhop et al. reported the analysis of a polysufide by capillary SFC and a dual SCD/FID system I6.7]. Chang et al. demonstrated SFC analysis of some sulfur compounds in garlic oil using dual SCD/FID system [6.81.

A simultaneous detection using CLND and FID for capillary SFC systems was achieved in this study and a schematic flow diagram is illustrated in Figure 6.6. The dual CLND/FID chromatogram for SFC of a mixture of 6 alkyldimethylamines in toluene is shown in Figure 6.7. A good peak for peak retention time correlation between the two detectors was observed. The advantage of the CLND is shown where the toluene (hydrocarbon solvent) peak is transparent to the CLND. Much stronger CLND response than the FID was observed for these dimethylamines (nitrogen compounds) with n-C8, n-C10, n-C12, n-C14, n-C16, and n-C18 alkyl functional group, respectively.

Figure 6.8 is the capillary SFC and dual CLND/FID chromatogram of a Japanese horseradish Wasabi extract in methanol. Notice the sensitivity improvement by the CLND over that of the FID. The methanol solvent blank by the CLND is shown by only the baseline without the methanol peak. The CLND profile for the Wasabi very clearly shows a much different composition from the CLND profile of the yellow hot mustard (Figure 6.4) and the horseradish oil (Figure 6.3). Wasabi consisted of two identified peaks A and B, allylisothiocyanate and phenylethylisothiocyanate, respectively. Both the hot mustard and Wasabi samples consisted of compounds found in the horseradish oil, but each having a different composition of hotness. When used in conjunction with organoleptic evaluations, the compositional

Page 497: Instrumental

480

HN H I

C" - C ~ C ----- C ~ N

H / f i H H

H \ H I

C ~ C -----C ----- S - C ~ N H / I I H H H \ H

I H/C ~ ~ - - - -C-- - - N ~ C I

H H

N = C ~ S

A = but-3-enonitr i le

B = al ly l thiocyanate

C = al ly l isothiocyanate

D = 2-buty l isoth iocyanate

N ~ C ~ S E = phenylethy l isoth iocyanate

Figure 6.2 Structures of the nitrogen containing components in horseradish oil standard.

Page 498: Instrumental

481

tlJ~

,i

O-

,, 0----~

~o E

b.

-- 0

0 ~

~ 0

c~ c~

'~

oE~

u

~o..~ ~

E

~-~

8~

�9 ~~

~

�9

,-~ t~

0

~.r �9

Page 499: Instrumental

482 <

w

~

~,~

d

o

-o

0 ~

0

o =

"~ o

f~

~ 0

.'~ .~

o~

~f~ ~ o

d

o ~

c'q i~ 0~

o_:

o~

, ~

I.., I-,

~ :IL

"~

~.~ •

.~ o ~

r.~ 0

o

.Z.," o I:I

r~

o

14 0 E o

rj

~

o ~t-..

Page 500: Instrumental

1.2,5-lutidine 2. Cnitrotoluene 3.2,S-dinitrotoluene. 4. Caffeine 5. lndole 6. Dimethoate 7. p-nitroaniline

3 14

7

L I

0

Time (min)

20

Figure 6.5 Supercritical fluid chromatography and chemiluminescent nitrogen detection of a mixture of several organic nitrogen containing compounds. Conditions: pressure program 100 atm (hold 4 min), ramp to 250 atm at 15 atm/min, then ramp to 340 atm at 30 atm/min (hold 3 min); Cyano column ( 2 0 m x 100 pm I.D., 0.25 pm film thickness); time split injection 0.2 sec; sample solvent: methanol; decompressed CO, 8.5 mL/min. H. Shi, J. T. B. Strode 111, L. T. Taylor*, and E. M. Fujinari, J. Chromatogr. A, 7 3 4 (1996) 303 with permission.

P 00 W

Page 501: Instrumental

484 c 0 o

N

~ m,,,~

c i

m

E

I11 5 D

m

It..

c E

m 0

0 U_

\ D

Z

_J 0

.=.d z_o~

,.4 em

o~,,~

Page 502: Instrumental

485

�9 .

o~

�9 ~ E

~ .-E

E.E_ ~, ~, ~

~~

~ _

" 0

.~..

,

ooo~~

~ o

---_._~

o

m

1.1.

:~ ~~-~

�9

.aO~o

m

~.~~ ~

~.~ .~, I1.

t~

~ .,i

..

..

.

..

..

Z

E

~

0

�9 ~

�9

a �9

~~

..

~'~

, ~

~.~

~

- .

~~ !~ ~ ~ ~.~ ~o_ .-~

~~

~

~

Page 503: Instrumental

486

(1)

e-

0 ~

0 m

'~

~ 0

oN, <

-)

0 t-

e- a m

n_

a z ..i 0

m 1

,,,,,,,,,t

o~=~ ~

�9 a

g b-':

rr

A

13= z~ ,-,1'5 v

Z rj o

,,--- .~

~ "t3

v s

E~

~ r j3

00

~

0 I:3,,o

,.,.

~176

I= .o E~ =L

x

o 0 _= o

o

Page 504: Instrumental

487

differences of these nitrogen containing compounds found by S FC-CLND in samples can be readily correlated to their flavor enhancing properties in a variety of foods. Additional information about S FC-CLND are reported in [6.5, 6.9, and 6.10].

Acknowledgements

The authors thank Antek Instruments Inc., for the loan of 705D nitrogen specific detector. We would also like to acknowledge Hewlett- Packard Company and Lee Scientific Division of Dionex Corporation for the loan of the S FC systems. In addition, many thanks to Air Products and Chemicals, Inc. for the donation of carbon dioxide.

6. REFERENCES

6.1 6.2 6.3

6.4

A. J. Britten, R & D, 31 (1989) 76. L. O. Courthaudon and E. M. Fujinari, LC-GC, 9 (1991) 732. S. M. Benn, K. Myung, and E. M. Fujinari, in "Food Fl, avors, Ingredients and Composition", G. Charalambous (Ed.), Elsevier Science Publishers, Amsterdam, (1993) 65. E. M. Fujinari and L. O. Courthaudon, J. Chromatogr., 592 (1992) 209.

6.5 H. Shi, L. T. Taylor, and E. M. Fujinari, J. Chromatogr.A, 757 (1997) 183.

6.6 A.L. Howard and L. T. Taylor, Anal. Chem., 65 (1993) 724. 6.7 D.J. Bornhop and B. J. Murphy, Anal. Chem., 61 (1989) 797. 6.8 H.C. Karen Chang and L. T. Taylor, J. Chromatogr., 517 (1990) 491. 6.9 H. Shi, J. T. B. Strode III, L. T. Taylor, and E. M. Fujinari,

J. Chromatogr.A, 734 (1996) 303. 6.10 H. Shi, L. T. Taylor, and E. M. Fujinari, J. High Resolu. Chromatogr.,

19 (1996) 213.

Page 505: Instrumental

488

"There is a growing number of researchers who are lucky enough to be working on the cutting edge of science. Some are fortunate to hang glide and soar beyond this edge to establish new boundaries. These are the hang gliders of science."

Eugene M. Fujinari Facilitator of Applied Chromatography and Detection

May 27, 1997

Page 506: Instrumental

D. Wetzei and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved 489

The SPECMA 2000 data bank applied to flavor and fragrance materials*

F. Colon and G. Vernin**

Laboratoire de Chimie des Ar6mes-Oenologie (CNRS, URA 1411) Facult~ des Sciences et Techniques de St-J~r6me, Case 561, Avenue Escadrille Normandie-Ni~men F 13397 Marseille C~dex 20

A B S T R A C T : After briefly reviewing our previous works since 1982 on the SPECMA bank, its originality, its specificity and its limitations due to the data processing of the time, we describe the modifications, improvements and the main functions of the new SPECMA 2000 bank. This, like previous versions, is based on the comparison between an unknown mass spectrum and a computerized library of reference spectra. Its contains a certain number of data such as the Kovats indices used as filters, the Registry Number, the descriptors and the olfactory thresholds when kown, the name, origin and bibliographical reference of the spectrum and a whole series of useful programs. It was conceived with a Pentium (Intel processor) whose designed RAM has been brought up to 16 Mo. It functions with ACCESS software via WINDOWS 95. A program of molecule design CHEMWINDOWS DB has been incorporated into the previous system. Thus, it has maintened all its interactivity and its originality while being more time saving and including several options. We give some examples of numerous spectra (among more than 4500) taken from our main topics of research: essential oils, spices and flavorings, Maillard and related model systems, fruits, wine and alcoholic beverages.

1. INTRODUCTION

Among the different methods of identifying by mass spectrometry of an unknown compound: theoretical, pattern recognition and comparative methods, the latter have proven to be the most efficient. That is why they have developed over the past 20 years. Initially, concerned with organic molecules in general, they became more and more specialized, in the form either of spectrum libraries, or of computerized banks, namely in the field of fragrances and flavors which interests the perfume and food industries. They are reviewed in another chapter of this book.

* The bank is not presently commercialy available but information can be obtained on demand. ** Author to whom correspondence should be addressed.

Page 507: Instrumental

490

Aware of the necessity for this specialization as early as 1982 we conceived a first version of a bank called SPECMA, devoted to the heterocycles of the Maillard reaction and of food flavors in general.

As a result of the progress made in data processing and software, this bank which was initially on CP/M was translated into the TURBO PASCAL (version 6) in the years 1985 to 1988 and extended to all the volatile compounds of essential oils, natural aromas and Maillard reaction as well as to similar related model systems (1-3).

Furthermore, we have introduced Kovats indices as filters in the search in order to distinguish between two products with similar spectra but different eluting orders on polar and non polar columns, when the mass spectrometry is coupled with the gas phase chromatography. This is the analytic technique which has been in general used since 1967 in this type of study.

With the incessant increase in the performance of data processing and sotfware, we have again created a new version of this bank called SPECMA 2000 with the same basic principles but using ACCESS via WINDOWS 95 software and a Pentium equipped with the Intel processor. Moreover a molecule design program (CHEMWlNDOWS DB) has been incorporated into the previous system. This is the version which we present with its applications in this chapter.

2. RECALL OF OUR PREVIOUS WORKS (1 -8)

The identification of a given organic molecule by mass spectrometry is based on three groups of methods

Theoretical methods or "Artificial intelligence" consist either in drawing a logical inference from structural information by examining the different spectra or in making suppositions concerning the structures, deducing the fragmentation patterns, then matching the theoretical spectrum with the unknown compound. The very insufficient theoretical knowledge of mass spectrometry appears to a non specialist to be very difficult to overcome.

Statistical methods called "Pattern Recognition" computerized under the name of "Learning machine", They consist in utilizing spectrum structures, empirical correlations enabling a rapid classification of the unknown compound into a given chemical family. This method seems to be of interest from only one point of view: the classification of a compound absent from the reference library by using some structural features.

Comparative methods or "Library Search" consist in comparing the unknown spectrum with every spectrum present in a MS data bank which must be as complete as possible. These last methods have appeared to many analysts to be by far the best ones since the development of the GC/MS technique in 1967.

Page 508: Instrumental

491

Owing to the drawbacks of the early MS data bank (lack of specificity, insufficient selection criteria, no discrimination between the spectra in the literature for a similar product, Kovats indices not used as filters etc.), in 1982, we decided to remedy this situation and to design our own data bank called "SPECMA".

The construction of a computerized data bank using comparative methods requires the solution of a certain number of problems which have been described elsewhere (5, 7). They are summarized in Scheme 1. a) The first problem is the mass spectrum specificity based on the double implication:

Identical compounds --~ Identical spectra

The first implication depends on the spectral reproducibility. This condition is connected with experimental conditions: i) the ionization voltage (usually 70 eV) ii) the type of apparatus (magnetic, quadrupole and more recently ion trap developed by Adams (9). Mass spectra obtained by this type of instrument are, in most cases, quite similar to those obtained with a quadrupole. Differences are greater between magnetic and quadrupole apparatus. Low intensity of fragments (m/z: 43, 41,39, 29, 27) are, as a general rule, higher with a quadrupole than with a magnetic. iii) the scanning position on the chromatographic peak. At the top a saturation phenomenon can be observed (several base peaks at 100%). If the mass spectrum is recorded very close to the edge, the presence of impurities can modify the spectrum. iv) with a too small amount of product, the spectrum is altered by a background noise. The second implication cannot always be borne out since various compounds (homologous, cis and trans, (Z) and (E) isomers have similar spectra. This is particurlarly the case with monoterpene hydrocarbons (with the exception of limonene) certain sesquiterpenic alcohols, and many other products. b) The second problem is the data acquisition and validation. Data acquisition can be made either from literature data or from our own GC/MS analyses. i) Literature data. They have been compiled in data bases (Wiley, TNO etc.)in specialized libraries, works or Atlases, in original papers, reviews, in the reports of congresses and theses (for references see the previous chapter) and (10 -13). Some of these sources are not always usable. Mass spectra are too small, without numerical values for intensities and uninterpretable; others give main fragments or a limited number of fragments classified in decreasing order of intensity causing a loss of information. On the other hand, experimental conditions are inaccurate or non-existent. Furthermore, some published spectra are very different for the same product due to an erroneous interpretation.

To solve these problems it is necessary to compare several spectra of the same product when available and to take into account authors' specializations in the field. Errors can also be detected by a good knowledge of the fragmentation process.

Page 509: Instrumental

492

IDENTIFICATION OF VOLATILE COMPOUNDS

BY GC/MS

LIBRARY SEARCH WITH LOW RESOLUTION MS DATA

1 MASS SPECTRUM SPECIFICITY

IDENTIFICATION CRITERIA I AND FILTERING (KI)

, , ,

1 CONSTRUCTION OF PROGRAMS[

l

I OATAAOOU, 's't'~ I

1 ! co~sT~OCT,O. OF ~'~Sl

1 MS DATA BANK I

Scheme 1. The flowchart of the MS-KI bank design (1)

Page 510: Instrumental

493

ii) Our own data. Laboratories possessing a combined GC-MS system set up their own bank. It is the most efficient solution but also the most costly and time- consuming. For the identification of each mass spectrum of a GC-MS listing it is necessary to first constitute a bank or a library of mass spectra arising from the literature. Answers given by the data bank (EPA/NIH, for example) coupled with the GC-MS system afford useful but limited information.

Encoding of mass spectra At the early stages of GC-MS analyses, microcomputers were not powerful

enough to store all MS data, i.e. fragments and corresponding intensities. For this reason, only a limited number of fragments with their intensities (5<N<10) were taken into account. The various methods described in the literature have been summarized elsewhere (5). The best encoding method for a spectrum seems to consist in (7): - Selecting N highest fragments with N high enough to take all important ones. - Taking N variables for every mass spectrum, because some of them are very simple and others contain a large number of fragments - Fragments of low intensity (< 10%) but characteristic of a given molecule: primary alcohols (m/z : 31), secondary alcohols (m/z: 45), alkyl esters (m/z: M + - OR and M + - COOR), alkyl derivatives (m/z" M + -CH3 and m/z" M + - 43) sulfur derivatives

(m/z: M + - SH and M + - SCH3) etc.. must be taken into account. The peaks at m/z' 28 and 32 a.m.u, must be discarded to avoid air peaks as well as the fragment at m/z: 207 (artifact)(with some exceptions). Whatever, there is always a loss of information between measurement and publication of a spectrum.

Choice of a comparison function If $1 are the intensities of an unknown spectrum and $2 those of a

reference spectrum, the comparison criterion can be reduced to a function F ($1, ..=,,,,1==~ $2) such that :

~ ~ ~ 2 ) $1 = $2 m F(S1, =0

The most simple bijection arises from attributing the ratio m/z = k, the kth coordinate of S (provided that m/z values are integer (5). In practice, the function F is always positive and the closer to zero F becomes, the more similar the spectra are. A threshold value FS is defined such that :

F ~< FS Identicalcompounds F > FS Different compounds

Different functions have been described in the literature and previously summarized (5). An original approach was applied by Petitjean (1) for the SPECMA data bank. The function used in this case allows one to work with variable tolerance with respect to the gaps in the spectra according to their origin.

Page 511: Instrumental

494

In this function"

oT,- F Sr, X, R) = F( Dr)

X and R are the lists of parameters for the unknown and reference compounds. These parameters take into account variations in experimental conditions and spectral quality.

Choice of Kovats indices as fi lters For many years we have recommanded the use of Kovats indices on polar and

non polar columns to differenciate various compounds giving the same mass spectra (3, 5). They possess a number of properties which can profitably be used as a route of identification. i) By definition, the Kovats index of a linear alkane CnH2n+2 is equal to 100 n; ii) They are little influenced by temperature changes and may be used with programmed temperature; iii) For the higher numbers of a homologous series, the Kovats indices may be expressed as:

Kin= KI + 100n

iv) For unsymmetrical substituted compounds ( R - X - R') Kovats indices may be calculated from symmetrical compound indices by"

K I ( R - X - R ' ) = [ K I ( R - X - R ) + KI (R ' -X-R' ],/~

v) On the basis of the Kovats' index of a parent molecule (PH), it is possible to calculate the indices of its derivatives by using the additivity of the substituent increments"

i KI = P- R = KI (P- H) + F_,(A)Ri + f (Ri, Rj)

where f(Ri, Rj) is a negative function taking into account the interaction of various groups Ri and Rj in the molecule. Its value depends on the polarity of groups. vi) The difference of Kovats indices (KID) on a polar phase (KIP) and on a non polar phase (KIA) is characteristic of a functional group:

KID = KIP - KIA

By definition, for a linear alkane, it is equal to zero. The more polar the column, the greater will be the KID of a polar solute and its family. Other filters such as the GC-FTIR technique are also used but they are very expensive and more or less efficient.

Page 512: Instrumental

495

The computerized data They have been initially divided into two sets called SPECMA.DAT and

NOMREF.DAT files, respectively. The SPECMA.DAT contains the following information: empirical formula (C, H, N, O, S, Z), molecular weight, mass spectra (up to 25 peaks with their El intensities), spectra in PCI and NCI, Kovats indices (KIA, KIP, KID) lower mass limit. The NOMREF.DAT file contains all other information which is not specifically useful for mass spectra searches, i.e, the name, odor and flavor descriptors with threshold values, registry number and reference. In the two files extensions have been anticipated. This data bank was first realized on a North Star Horizon microcomputer of 64 K bytes, equipped with a dual 8" floppy disk unit. It was run by CP/M. The source program (PL1 80) was parameterized so as to optimize adjustments to various types of diskettes. In 1985, the bank was implanted on an IBM microcomputer using TURBO PASCAL, version 3 and then version 6 as software. This version was saturated with 4.000 spectra. On the other hand, products being classified by increasing molecular weight, input of a new product of low molecular weight was very time- consuming. For all these reasons and taking into account the increased performance of microcomputers and software, a new revision of the bank was undertaken using ACCESS via WINDOWS 95 and a Pentium (RAM16 Mo), Intel processor (14).

3. SPECMA 2000 DATA BANK: REALIZATION

3.1. New modifications relative to the previous versions

- Choice of ACCESS as data base. The first versions of the bank were developed by using proprietory languages

(PL1/CPM, TURBO PASCAL) whose major disadvantage was the lack of versatility and evolutions before a new developing standard, such as WINDOWS. By choosing ACCESS developed by MICROSOFT, these disadvantages could be mastered and it was hard to imagine that the inventor of WINDOWS, MICROSOFT, would not continue to develop its only data base. The use of a language such as MICROSOFT'S VISUAL BASIC would have equally been a good choice. But ACCESS gives the user greater liberty, allowing personal modules to be added without being enclosed in a compiled program. After a few "bugs" in the first versions of ACCESS a rather radical modification of the data access programming methods was to be found in version 2 which lead us partly to reprogram once those.

The current version of the bank functions on ACCESS version 7. The programming methods have again been modified to come close to VISUAL BASIC. Finally, MICROSOFT has created an efficient product , completely integrated in the 32 bit environment of WINDOWS 95. It is pleasant and easy to use so that a non-expert may question the data base or create his own display screens.

Page 513: Instrumental

496

- The different tables used Because the new SPECMA bank is not limited by the number of compounds,

the use of a data base was called for, in order to overcome the inherent difficulties in programming file management and numerous recordings. In ACCESS the latter are stored in tables. The main tables are defined as follows: * The TBANQUE table contains the list of all the compounds and each recording is numbered singly, unlike the previous versions. * The TPICS table contains all the fragments of all the compounds. A field containing the number of the corresponding compound enables all the fragments of a given compound to be found.

These two tables are essential for the operation of the bank. Other tables allow the application to be managed. These tables are bonded to each other so as to maintain a certain logic. For example, it is important for each peak of the TPICS table to be matched by an associated compound in the TBANQUE table. This is checked by ACCESS thanks to the referential integrity mechanism.

- Referential integrity This is an essential concept when relations between different tables are to be

dealt with. Its guarantees the integrity of the base. When using the bank, the consequences are numerous for the constraints it imposes are effective in the options: up-dating, deleting, additions. In our case, this integrity is confirmed between the TBANQUE and TPICS tables. One single compound corresponds to each peak recorded in TPICS. When a compound is deleted, the associated peaks must be deleted in the TPICS table.

- Numbering the compounds Each compound possesses a single, permanent number coded by ACCESS.

This number is chosen interactively but without reusing the attributed numbers, even if the number belonged to a deleted compound. But after repeated creations and deletions, this numbering is not at all continuous. The solution of renumbering all the compounds is too complex but is conceivable.

3 . 2 . R u n n i n g of the da ta bank: v a r i o u s o p t i o n s

The SPECMA 2000 data bank has been conceived in such a way to simplify the operations which were necessary in the previous versions written in TURBO PASCAL (versions 3 and 6). Numerous options have been added rendering the management of the compounds and the search program easier. The "MAIN MENU" called "COMPONENTS MANAGING" allows the various options of the bank to be accessed (See Figures 1 and 2). -" FAST LIST " allows all compounds to be shown. The latter are classified according to alphabetical order. In the present case we choose the ~ letter from the lower left-hand part of the screen (A, B, C...E .... Z) and check the 2-ethoxy-3- ethylpyrazine as an example (N ~ 1465) (darker on the screen). The right-hand part contains the seven options of the bank which are summarized below (Figure 2).

Page 514: Instrumental

497

Figure 1. SPECMA 2000 Data bank: Presentation and "MAIN MENU" called "COMPONENTS MANAGING"

Page 515: Instrumental

498

t~9 "0 t--

O

O.

E 0 0 t--

O9

~z 0

.i 0

0") ..d

F-- O

9

LL

c~

.~

Page 516: Instrumental

499

-"CHECKING OF A COMPOUND". The "check" switch allows a compound to be shown (N ~ 1465, see Figure 2) and subsequently, printed or modified using the corresponding options. -",,s allows the mass spectrum of the checked compound to be displayed directly on the screen. A switch "ZOOM" enables the spectrum to be enlarged and a choice between the different ionization techniques (El, PCI, NCI modes) to be made (See Figure 3).

Figure 3. SPECTRUM option. As an example: 2-Ethoxy-3-ethyipyrazine (N~

-"MODIFY" The modification switch allows all the data concerning the checked compound to be modified (See Figure 4)i.e. Name, Kovats indices, Positive lists (15), Molecular formula, Registry Number (CAS), Reference to Chemical Abstracts, Descriptors and Threshold values, Family and Sub-Family, Occurrence, the Mass spectrum and the Drawing of the molecule in the lower right-hand part of the screen (or to be corrected, if necessary). The "CANCEL" switch allows exit from the page without any change. The "SAVE" switch, on the contrary allows the modifications to be stored.

Page 517: Instrumental

500

e-- 0 o

Z

�9 I.--

r tl �9 z~

1.1..

Page 518: Instrumental

501

- "PRINT" This switch allows access to a dialog box which suggests the standard printing options (See Figure 5).

Figure 5. "PRINT" option

- Printing of a checked compound - Printing of a set of checked compounds - Search parameters used when the operator wants to print the result of the

unknown compound search (See Figures 7 and 8). -"DELETE" This option deletes each compound after entering its corresponding number. This is not used again. The program asks YES or NO. - "NEW" This very important option allows the input of a new component into the bank (See Figure 6). The data acquisition screen for a new compound is divided in two distinct parts: the left side contains the field of data acquisition of the compound description and the right side the mass spectral data. Pressing this switch induces the appearence of a blank data acquisition screen. These data include: - Usual name, synonyms and chemical name - Origin and reference of the mass spectrum - Molecular formula" Cu, Hv, Ow, Nx, Sy, Zz, and molecular weight which is immediately calculated. - Kovats indices on non-polar (IKa) and polar (IKp) chromatographic columns at programmed temperature, as well as DIK which is characteristic of a given family. It is also used as a filter in the search option.

Page 519: Instrumental

502

0 O_

0

D Z

�9 13.

�9 o U.I z .

~

Page 520: Instrumental

503

- Numbers on positive lists (FEMA, CoE, IOFI )(15) - Registry number (CAS) - Reference to Chemical Abstracts of the paper giving the mass spectrum. - Descriptors including odor, flavor, aroma taste and the corresponding threshold values when they are available (16-24). Computerized structure-odor relationships are of interest to classify an aroma compound according to its structure. Numerous methods have been developed and works are in progress (25, 26). - Families to which the compound belongs. They have been classified as follows:

- Alicycliques - Aliphatics - Aromatics - Diterpenes - Fused heterocyclic compounds - Heterocycles

- Irregular monoterpenes - Monoterpenes - Nor-isoprenoids (C13) - Sesquiterpenes - Triterpenes

- Sub-Family. In each family compounds have been classified in various categories. Sub-families for heterocycles are given in Figure 7. - Occurrence. This option concerns the flavor and fragrance field in which the compound has been found. The following topics have been chosen:

- Alcoholic beverages - Essential oils - Essential oils and Maillard - Fruits and essential oils - Fruits and wines - Vegetables

- Fruit, wines, alcoholic beverages - Grapes - Maillard/Model systems - Spices - Synthesis - Tea, coffee, cocoa

- Wines, alcoholic beverages and Maillard This list is not exhaustive. When several compounds are added to the bank, they are numbered by increasing order. This number is automatically attributed by ACCESS to the file during the data acquisition and cannot be modified. - Mass spectrum. After the occurrence data, the runner set on the mass spectrum:

mass intensity Mode (El, PCI or NCI)

The number of fragments and their intensities are unrestricted. After "SAVE" the compound is recorded under is own number. The "MODIFY" option then allows the corresponding molecule to be drawn using the CHEMWINDOW DB program and to be inserted into the mass spectrum. - "SEARCH" option. With ~ it is one of the two options most in use (See Figure 8). It allows a compound to be searched using all the described data for the I.'.NEW" option. By pressing the "SEARCH" (or SEARCH COMPOUNDS) switch, the screen appears showing all the various possible data to be entered. - If we want to search a compound using "USUAL NAME", it is enough to type a part of the name. However, the latter must be quite precise in order to avoid too great a number of answers.Kovats indices are given at +/- 2% and DIK at +/- 4% in order to take into account the difference in experimental conditions for polar and non-polar columns, respectively. A range for molecular weight is scheduled in the case where it is unknown.

Page 521: Instrumental

504

Figure 7. "FAMILY" sub-option.

Page 522: Instrumental

505

o ~

Q.

0

a z �9

r~

�9

o T 0 r~

iii

ii

Page 523: Instrumental

506

In opposition to the previous versions of the bank, it is not necessary to enter by the keyboard all fragments and their intensities for the mass spectrum. Usually, the two, three or four most important fragments are sufficient. The corresponding intensities are entered with a range of error from 0 to 100%, chosen by the user. If the result is not satisfactory the range can be changed with the switch "CLEAR ALL". The input of molecular weight and Kovats indices greatly improves the search. It is possible to correct an error at any time. As an example, the search for 2-ethoxy-3-ethylpyrazine is given in Figures 9 and 10. We choose various intensities and error ranges (20, 40, 40, 50%) for the four highest peaks at m/z: 124, 123, 95 and 152, respectively. In both cases, the program gives the right result, showing the interest of this approach relative to the use of a function. When we want to execute a new search, the "CLEAR LAST SEARCH" switch allows all the parameters of the previous search to be deleted. The fields of the screen are automatically deleted at the time of starting up the bank or when "COMPONENTS MANAGINg" appears. Second example of search: Gleenol case (Figure 11 ). Recently, in his book Adams published the mass spectrum of gleenol (9). This product has been found in our recent study on the Helichrysum Stoechas (overlasting) essential oil harvested in (Alpes de Haute Provence). The two mass spectra (El) have been input in the SPECMA bank (See Figure 11). In order to study the influence of the range of error concerning intensities and to find these spectra again by the SEAR(~H option, this latter has been varied. The three most abundant fragments have been taken into consideration and they are reported below with their corresponding intensities.

ADAMS m/z Int. Error GC/ITMS a) range

121 100 30-50% 81 73 40-50% 41 70 80-100%

VERNIN m/z Int. Error GC/QMS b) range

81 100 30-40% 121 83 20-30%

41 44 60-80%

a) Ion trap mass spectrometer(9) b) Quadrupole mass spectrometer

Only the two mass spectra have been found with the above reported values for the range error. Below these values only a mass spectrum was found. These preliminary results emphasized that for an unknown compound fragments of high intensity (60 to 100%) near the base peak, a range of error from 30 to 50% must be taken into account.

Page 524: Instrumental

507

FIRST PROPOSAL ISearch parameters:-" I

Usmd mmae:

Orlgta & r e f :

M ~ fonaula:

IKA:

FEMA:

l O O

8 0

C H O N S (152)

1080 IKP: 1430 DIK: 350 COE IOFI :

- E l

. =

95 , =

. . . . , , . . . . , . . . . , . . . . , . . . . ,

20 40 60 80 100

El: 124(100) 123(70)95(50) 152(43)

I~N (CAS): CA:

Descriptor odor/Flavor.

124

123

152

L

, , - , . . . . ~ . . . . i , , , ' ~ w ; ~ , , ~ , , , - i , ~ - , r , •

120 140 160 180 200 220 240 260 280 300 320

100 -EI

8 0 -

6 0 -

411

20

41

81

t 67 ++

~ ~ _

| | + w r l w | | , I . . . . i I ' T I + i , • ,

0 20 40 60 80

II + 100 120

124 123

152

i

- , , , , , ,~ . . . . ~ " , , ' , . - : 1 ; , , - ~ . . . . . . . . . . . . 1 ~ 1 ~ l ~ 2 ~ ~ O 2 ~ 2 ~ 2 ~ 300 320

El: 124(100) 123(94) 96(71) 152(60) 41(60) 81(42) 57(32) 68(30) 107(27) 108(25) 56(25)

Figure 9. Search for 2-ethoxy-3-ethylpyrazine using different range errors.

Page 525: Instrumental

508

FIRST PROPOSAL [Search parameters: I

Usual name:

O r l r l . & r d :

Molecular formula: C H O N S (152)

IKA: l l 15 IKP: 1460 DIK: 345

FEMA: COE IOFI:

100 -- ' ' -El

95

. . . . i . . . . i . . . . , . . . . t , , , 0 20 40 60 80

8 0 -

6 0 -

4 0 -

2 0 -

0

El: 123(1(30) 124(80)95(60) 152(70)

ILN (CAb'): CA:

Descr iptor odorfFlavor:.

123

124

152

, . . . . ! , , , , . . . . , , , , , , . . . . ; . . . . i , , r , ; . . . . I . . . . , . . . . ; . . . . 100 120 140 160 180 200 220 240 260 280 34}0 320

100 - E l

8O

60

40

20

0 , . . . .

95

81

iI'! 1" . . . . ! ' ' , ' i , , , I , " l ,

1:24 :123

, , I , , , t , , 1

0 20 40 60 80 100 120 140 160 180 200 220

El: 124000) 123(94) 95(71) 152(60) 41(60)81(42) 57(32) 68(30) 107(27) 108(25) 56(25)

, t . . . . I . . . . t . . . . I . . . . I . . . . I . . . . t . . . . t . . . . 240 260 280 3O0 32e

Figure lO. Search for 2-ethoxy-3-ethylpyrazine using different range errors.

Page 526: Instrumental

509

lOO

- 1 2 1 8 0

_

60- HCY'""

40- 41, } 1 16s69 93 108

i 222 [~9 ~71~[~"~ 1 09 122 IJ11'345 l l6l ,,~nA o , . , , , , . . . . ~ - - , , , I , , , . . . . . . . . i . . . . i ' " ' , ~ , . . . . , . . . . , . . . . , . . . . i . . . . , . . . .

0 20 40 60 SO 1 O0 120 140 160 180 200 220 240 260 ZSO 300 t20 El: 81(100) 121(83) 93(45) 108(45) 41(44) 69(29) 39(10) 43(18) 53(7) 55(20) 57(10) 67(9) 68(8) 91(13) 107(22) 109(11) 122(10) 135(5) 136(6) 161(6) 179(3) 191(2) 204(4) 222(15)

F i g u r e 1 1 . M a s s s p e c t r a o f g l e e n o l .

Page 527: Instrumental

510

o ~

o

�9 i--.- .< ....i Z3 r ._d

r r 1.13 r IZI Z O9 I--- < �9 ,,e'

e,i 'T

"--

z~ ~

!1

Page 528: Instrumental

511

For the fragment at m/z 41 whose intensity greatly changes according to experimental conditions and apparatus 80 -100% error range is necessary (or it must even be squarely eliminated). The choice of this range of error is left to the skilled user! - Misr There are other options which have not been described" "SHOW ALL COMPOUNDS" and "LAST ENTRIES (See Figure 2). The first switch allows all the components present in the bank to be filed off using the runners set on the right side. To select a compound more quickly, it is necessary to use the switches (i.e. alphabetical letters) set below the list. Compounds beginning with the selected letter can be visualized. The switch "LAST ENTRIES" allows the compounds to be sorted according to the recording date. This option is particularly suitable for finding the compounds last recorded. These compounds appear first in the list allowing them to be found easily again.

The "MAIN MENU" (See Figure 1) besides "COMPONENTS MANAGING" contains the "OTHER FUN(~TIQN$" option. The latter concerns K.OVATS INDICES CALCULATIO..N which allows from scans (X) and known Kovats indices (Y) of compounds identified in the GC/MS listing on the left-hand part of the screen to be calculated (See Figure 12).

In the middle part, the program gives the linear equation �9

Y= ax=b (Y=KI and X=scans)

as well as the correlation coefficient (r). It ranges usually between 0.98 - 0.99 for a limited number of Kovats indices unities range (~200). The equation is not linear along the scan listing. The right-hand part allows all Kovats indices from the corresponding scans to be calculated. This version is an enlargement of our previous MBASIC SCAN1 program (See the previous chapter).

A p p l i c a t i o n s

The earlier versions of the SPECMA bank have been tested with more than several hundreds of volatile components of essential oils (27-39), spices, herbs and flavorings (40-53) Maillard reactions (54-60) and related model systems, fruits (61-65), wines and alcoholic beverages (66, 67). The reader is referred to these references for more details. Further on, several examples using the SPECMA 2000 data bank and belonging to the previously cited works are reported. They will be completed subsequently.

A c k n o w l e d g e m e n t s -

The authors are indebted to the Central Analytical Service of the CNRS, Vernaison and the Mass Spectrometry Service, Marseilles (Mrs. C. Chariot) for recording GC/MS analyses. Thanks are also due to Mrs. G.M.F. Vernin and Mrs.R.M. Zamkotsian for their collaboration.

Page 529: Instrumental

512

100 -EI

80 _

60

40

20

0

i

93

79 121

gO ) 1

43 3 105 l 107

. . . . ~ . . . . i , , , , , , , I , , , t . . . . ' 1 3 o , , t . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 9 3 ( 1 0 0 ) 7 9 ( 6 0 ) 1 2 1 ( 6 0 ) 7 7 ( 4 1 ) 8 0 ( 4 1 ) 9 1 ( 4 1 ) 4 1 ( 3 4 ) 6 7 ( 3 2 ) 1 0 5 ( 2 3 ) 5 3 ( 2 0 ) 6 3 ( 2 0 ) 5 5 ( 1 8 ) 4 3 ( 1 6 ) 1 0 7 ( 1 6 ) 1 3 6 ( 2 )

Page 530: Instrumental

513

Chemical name: 1,3,3-TRIME TRICYCLO-2,2,1- HEPTANE N ° 723

Origin & ref: ARTEMISIA HERBA ALBA,(ALGERIA),VERNIN et aI.,"FOOD FLAVORS",ELSEVIER,37A, 147-205,1995.

Molecular formal C10 H16 (136) R.N (CAS): 508 32 7 CA: 0:0

IKA: 925 IKP: 1038 DIK 113 Family: Monoterpenes Hydrocarbons (C10H16; MW 136) FEMA: 0 COE 0 IOFI 2

Descriptor odor/Flavor

100 ' -EI

40

121 136

~ I~_, 1~7l 9_4 ] 11°¢~7_ . . . . i . . . . , . . . . , . . . . i , , ,~ . . . . , , , , I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I , , , I . . . . I . . . .

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El : 9 3 ( 1 0 0 ) 1 3 6 ( 2 7 ) 1 2 1 ( 2 6 ) 9 2 ( 2 3 ) 9 1 ( 2 2 ) 4 1 ( 2 0 ) 7 9 ( 1 5 ) 3 9 ( 1 4 ) 7 7 ( 1 3 ) 1 0 5 ( 1 0 ) 9 4 ( 9 ) 5 5 ( 6 ) 6 7 ( 6 ) 1 0 7 ( 6 )

Chemical name: BICYCLO[3.1.0] HEX-2-ENE,2-METHYL-5-(I-METHYLETHYL) N ° 4871

Origin & ref: CELERY SEEDS E.O.;VERNIN et aI.,"SPICES,HERBS...",ELSEVIER,34,329-345,1994.

Molecular formal C10 H16 (136) R.N (CAS): 2867 05 2 CA:

IKA: 930 IKP: 0 DIK 105 Family: Monoterpenes Hydrocarbons (C10H16; MW 136) FEMA: 0 COE 0 IOFI 2

Descriptor odor/Flavor

1oo

80

60

40 77

20

27 _ 41 ]79 136

i , ,, i 165 l ln~ , . . . . . . . . . . . . . . , , , , i . . . . i .'-01 , I . . . . I . . . . I . . . . I . . . . I , , , , I . . . . I . . . . I . . . . I . . . .

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El : 9 3 ( 1 0 0 ) 9 1 ( 4 8 ) 9 2 ( 3 3 ) 7 7 ( 3 8 ) 4 1 ( 1 7 ) 2 7 ( 1 5 ) 1 3 6 ( 1 2 ) 1 2 1 ( 3 ) 1 0 5 ( 5 ) 7 9 ( 2 0 ) 6 5 ( 6 )

Page 531: Instrumental

514

1~) -EI

80 173

60

411

/

0

20

!

o 20 40 60 80 1oo 12o 14o 16o 18o 200 220 240 260 280 300 320 El: 44(100) 73(~) 42(5O) 3O(3O) 2O(25) ~(10)

Page 532: Instrumental

5 1 5

100 43

80

60 0

44 40

,~ , ~ ~ ~6 1 2 I 114 I'o

. . . . ' , t . . . . I . . . . '1 . . . . I . . . . ! . . . . I . . . . t . . . . ! 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 4 3 ( 1 0 0 ) 7 3 ( 9 3 ) 7 2 ( 7 2 ) 4 4 ( 4 8 ) 5 5 ( 1 9 ) 4 2 ( 1 8 ) 41 (25 ) 60 (26 ) 3 9 ( 1 6 ) 86 (23 ) 114 (14 ) 129 (5 ) 7 0 ( 1 0 )

Page 533: Instrumental

516

100

80

60

40

2O

43

163

o

0 zo 40 6o so 100 120 140 ~60 180 zoo zzo z40 260 zso 300 320

El: 104(100) 43(54) 91(28) 72(27) 163(20)

Page 534: Instrumental

517

100

80

60

40

20

-El

29 27

44

:1 56

43

7 57

14:5 I[~ i72 82

0

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 44(100) 27(82) 29(90) 39(31) 41(75) 43(52) 45(17) 53(5) 55(16) 56(73) 57(42) 67(10) 71(5) 72(18) 82(13)

Page 535: Instrumental

518

100

80

60

40

20

i

43

144

6 82

. . . . i . . . . . . . . . . . . i , , , l ' i ,,I, 20 40 60

0

C 8 H 1 7 ~ , , ~ H

I12

lO

, I , , ! 2 ~ , ' ? , ~ _ . . . . , . . . . , . . . . . . . . . . . . . . . , , , , ~ , , . . . .

80 100 120 140 160 180 200 220 240 260 280 300

El: 57(100) 43(88) 44(70) 70(59) 71(56) 68(56) 55(53) 82(49) 56(45) 112(34) 67(33)81(32) 41(31) 83(29) 95(26) 45(24) 96(22) 42(21 ) 110(15) 128(6) 138(5)

320

Page 536: Instrumental

519

nl 100 -El 108

4O

95 2O "'17:!7 ll" [' 109

o , 1~9 | , . . . . i1~9 . . . . . . . . , . . . . . . I . . . . . . . I . . . . I . . . . t . . . . I . . . . t . . . . t . . . . t . . . . I . . . . t . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 1 0 8 ( 1 0 0 ) 6 7 ( 3 7 ) 4 1 ( 3 5 ) 9 5 ( 2 9 ) 1 0 9 ( 1 9 ) 8 2 ( 1 7 ) 9 3 ( 1 7 ) 3 9 ( 1 6 ) 4 3 ( 1 6 ) 5 5 ( 1 5 ) 8 1 ( 1 4 ) 5 7 ( 1 1 ) 2 9 ( 8 ) 1 1 9 ( 6 )

Page 537: Instrumental

520

I0080 I El_

60- _ 77 40- 51

- 4 1781]~021103 2 0 -

~19 11104

0 20 40 60 80 100 120

132 H

, t . . . . I . . . . I . . . . I . . . . I . . . . I . . . . t . . . . I . . . . I , ~ , ' ,

140 160 180 200 220 240 260 280 300

El : 131(100) 132(63)51(46) 77(56) 78(38) 103(39) 104(15) 102(8)39(12)43(6) 320

Page 538: Instrumental

521

11111

8 0 -

4 0 -

i | |1

- E l

i

0

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 83(100) 55(34) 41(11) 39(10) 69(4)

Page 539: Instrumental

5 2 2

loo

80

60

43

121

164

0

0 2o 4o 60 so ]oo ]2o ]40 ]60 ] ~ 2oo 22o 240 260 z ~ 3oo 32o

El: 107(100) 164(45) 43(45) 77(18) 121(15) 94(12) 91(10) 149(6) 65(6)

Page 540: Instrumental

523

lOO -EI 0

60

40 [43 103 121

45 92

1 '11 t 27 1 79

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 91(100) 103(45) 121(44) 27(13) 39(18) 41(9) 43(40) 45(28) 51(15) 63(9) 65(23) 77(18) 79(9) 92(28) 120(17) 146(24)

Page 541: Instrumental

5 2 4

100 -EI

8 O

6 O 6 9

_ 1 2 3

40 8 l

I I 7 I ~.51107~ f 1149 20 21

109.1 . _ 0 I ' ' - . . . . i , , j , , , ' " . . . . . . ! , , , ! . . . . . . . .

0 20 40 60 80 100 120 140 160

192

i

0

I I , , , ' , 1 . . . . I . . . . I . . . . I . . . . I . . . . I . . . .

180 200 220 240 26,0 280 300 320 E l : 177(100) 41(33) 43(33) 51(4) 53(8) 55(17) 67(10) 69(65) 77(8) 79(15) 81(42) 91(15) 93(17) 95(21) 107(27) 109(10) 121(25) 123(56) 135(21) 149(38) 192(40)

Page 542: Instrumental

525

l ib

60

40

20

58

\ 0

(CH2~'~

0

0 20 40 60 80 100 120 14o 16o 18o 200 220 240 260 280 300 320

El: 43(100) 58(88) 59(50) 41(28) 55(18) 71(17) 57(13) 29(12) 85(5) 96(4) 226(2)

Page 543: Instrumental

526

100

80

60

43

108 i

OH

109

152

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 108(100) 41(15) 43(20) 55(14) 69(7) 77(6) 91(7) 152(7) 207(2) 109(22)

Page 544: Instrumental

527

100 -El 41 _

8 0 " _

6 0 -

_

~ O H

40 - 67

0 . . . . i . . . . , . . . . , . . . . i . . . . I' l u t t , I , , , ' , t T", , , I . . . . I . . . . ! . . . . t . . . . t . . . . i . . . . I . . . . I . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

E l : 4 1 ( 1 0 0 ) 5 5 ( 3 5 ) 6 7 ( 4 2 ) 8 2 ( 2 2 ) 6 9 ( 1 5 ) 3 1 ( 1 9 ) 2 9 ( 1 5 ) 2 7 ( 1 7 ) 4 2 ( 2 2 ) 4 3 ( 1 0 ) 3 9 ( 2 0 ) 1 0 0 ( 1 )

Page 545: Instrumental

528

100

80

85 l

139

El: 43(100) 59(45) 85(27) 41(24) 81(20) 139(12) 67(6) 55(15) 96(12) 31(9) 95(11)97(8) 69(7) 121(6) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

Page 546: Instrumental

529

100 -El' _

67 4O

20 55 !

43 1 96 - , i~ ,~ .11t9 . .

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 95(100) 67(49) 41(29) 55(26) 81(15) 53(14) 43(12) 79(12) 96(12) 77(8) 139(5) 121(3) 111(1) 154(1)

Page 547: Instrumental

530

100 -EI

80

60

40

20

0 I . . . . i , ,

0 20

31 4 ~4~ 9

4O

61

. . . . I . . . . I , 60 80 100

~ S ~ O H

, , , I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . .

120 140 160 180 200 220 240 260 280 300 320

El: 1 0 6 ( 1 0 0 ) 6 1 ( 8 2 ) 5 8 ( 7 0 ) 5 7 ( 6 9 ) 4 1 ( 5 0 ) 4 9 ( 5 0 ) 4 7 ( 4 7 ) 3 1 ( 4 5 ) 4 8 ( 3 8 ) 4 5 ( 3 6 ) 5 5 ( 2 5 )

Page 548: Instrumental

531

100 -EI 4 73

8 0 l l 3 ~ ~ ' , , . ~ S ~ s / S ~

6 0

4 0 15

2 0

l '~ . . . . I . . . . . . . . I . . . . i . . . . i . . . . I . . . . I . . . . i . . . . . ~ $ 6 . ! . . . . I . . . . I . . . . I . . . . ! . . . . I . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 7 3 ( 1 0 0 ) 4 1 ( 9 8 ) 1 1 3 ( 8 0 ) 4 5 ( 4 0 ) 3 9 ( 4 7 ) 1 7 8 ( 1 0 ) 1 8 0 ( 2 ) 1 0 3 ( 1 5 )

Page 549: Instrumental

532

100

8 0 "

6 0 -

4 0 -

2 0 -

o - I. 0

108 150

El: 43(100) 27(22) 39(15) 41(31) 44(6) 59(3) 45(3)66(3) 69(3) 72(6) 108(17) 109(3) 150(11) 20 40 60 80 1 O0 120 140 160 180 200 220 240 260 280 300 320

Page 550: Instrumental

533

100 111

71 40 "~ 27

.. 56

20 [83

0 . . . . i . . . . . . . . i , , I . . . . . 0 20 40 60 80 100

, I, ,1261 .... I .... I .... I .... I .... I .... I .... i .... i ....

120 140 160 180 200 220 240 260 280 300 320

El: 111(100) 43(86) 55(80) 71(53) 27(45) 67(45) 56(36) 41(29) 99(30) 83(24) 126(13) 39(25)

Page 551: Instrumental

534

100 -Ez 85 '

60 08HI 0 0

40

. . . . . . . . ~ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: ~(100) 27(12) =~39) 41(18) ~(14) ~(~4) ~(~5) 57(~ 6) ~(12) ~(6) ~ ~(4) ~(6) 128(9) 136(3)

Page 552: Instrumental

535

100 -EI

~o~

6o.~

40 142155 I~

- IIII I,,; 41 20

. . . . ~ . . . . ~ . . . . i . . . . , , r g 4

0 20 40 60 80

114

. . . . i . . . . | I, L'-a-. , i . . . . | . . . . i . . . . i . . . . ! . . . . ! . . . . I . . . . I . . . .

100 120 140 160 180 200 220 240 260 280 300 320

E l 9 9 ( 1 0 0 ) 4 2 ( 4 4 ) 5 5 ( 4 4 ) 7 1 ( 4 4 ) 7 0 ( 4 4 ) 4 1 ( 2 8 ) 2 7 ( 3 1 ) 2 9 ( 2 7 ) 6 8 ( 1 1 ) 6 9 ( 1 1 ) 1 1 4 ( 1 4 ) 8 4 ( 6 ) 1 4 2 ( 3 )

Page 553: Instrumental

536

100 -El 107 _

8O

611, 2

40 "~ 108 167

" 141 ' - 91 109 20 9 53

- 1 | . . . . . 165 I ; 1151 1182 . . . . I . . . . , . . . . . . . . . . . . i . . . . i . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . . I . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 107(100) 108(44) 167(39) 41(35) 91(23) 108(22) 39(20) 53(17) 135(15) 43(13) 77(11) 79(11) 151(8) 182(7) 65(6)

Page 554: Instrumental

537

IO0

8 0 "

6 0 -

4 0 -

2 0 -

o ~

176 0 - zu..t z..to

0 20 40 60 80 100 120 140 160 180

El: 131(100)43(7)51(18) 77(15) 103(28) 147(10) 132(8) ~76(~2) ~ ( 6 ) ~04(6)

131

200 220 240 260 280 300 320

Page 555: Instrumental

538

100

8 0 -

6 0 -

4 0 -

2 0 -

0 i . . . .

0 2O

81

123 H~ . . . . . .

41 /

55 67 I07 22

lli"M~ 1182 . . . . , . . . . . . . . i . . . . i . . . . , . . . . | ' ' l ~ r / | . . . . i . . . . I . . . . t . . . . I . . . . i . . . . I . . . .

40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 8 1 ( 1 0 0 ) 1 2 3 ( 7 5 ) 1 0 7 ( 3 0 ) 4 1 ( 4 5 ) 5 5 ( 3 5 ) 5 9 ( 2 5 ) 6 7 ( 3 8 ) 6 9 ( 2 5 ) 7 9 ( 2 6 ) 1 2 2 ( 2 8 ) 1 3 9 ( 5 ) 1 4 0 ( 4 ) 1 5 2 ( 1 9 ) 1 5 3 ( 1 5 ) 1 6 7 ( 1 ) 1 8 2 ( 7 )

Page 556: Instrumental

539

100

80

40 I

i i i n

0

20 - 55 _

92 0 -

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 91(100) 83(33) 82(3) 55(22) 65(7) 77(3) 79(3) 92(10) 190(2) 172(3)

Page 557: Instrumental

540

100

80

60

40

20

. 1 4 3 _

. . . . i . . . . I . . . . I . . . . i . . . . I ' , , 20 40 60 80

..... 197 ' 1 , , ,',:?r3 I t I I~1~ ~ ' ~ . . . . . . . . . . . . . . . . . . . . , . . . . , . . . . , . . . . - . . . .

100 120 140 160 180 200 220 240 260 280 300 ,320

C 6 H 5 C H : C H C H 2 0 0 C ~ (Z) H

El: 83(100) 82(3) 55(70) 43(12) 97(6) 115(25) 117(21) 133(3) 216(5)

Page 558: Instrumental

541

100

80

40

20

0 20

'55 183

gl

41 ' '82

I i

11o 40 60 80

123

109

, 1

. . . . . . . .

100 120

138

0

. . . . I . . . . I , , I . ~ I . . . . . I . . . . I ' . , , , t . . . . I . . . . I . . . . 140 160 180 200 220 240 260 280 300 320

E l : 83(100) 55(97) 81(89) 95(78) 82(74) 41(73) 69(64) 123(62) 67(49) 138(43) 68(33) 109(29) 96(18) 43(14) 56(13) 53(12) 57(12) 101(12) 80(8) 94(7) 191(2)

Page 559: Instrumental

542

100 -EI

80

60

0 ~ o c � 8 9

40 91

151 65 1194 0 I . . . . i . . . . i . . . . i . . . . ~ . . . . i . . . . i . . . . i . . . . i , ' , , , 5 ~ i . . . . '; . . . . i . . . . ; , , , : ; . . . . i , , , - . . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

E l : 1 0 5 ( 1 0 0 ) 2 1 2 ( 2 7 ) 5 1 ( 1 0 ) 6 5 ( 1 0 ) 7 7 ( 2 4 ) 9 1 ( 4 5 ) 1 9 4 ( 7 ) 1 6 5 ( 2 )

Page 560: Instrumental

5 4 3

100 -EI

80

6O

40

20

0 ~(CH2)14-'~0~ l i 101

. . . . , . . . . , . . . . . . . . . . . . = . . . . ; . . . . ~ , A , J , ~ ' z ; . . . . I . . . . i . . . . , . . . . , , , z ~ 4 ; . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 88(100) 101(50) 43(51) 41(46) 55(33) 57(23) 60(13) 61(10) 69(14) 70(12) 73(13) 89(12) 143(5) 157(5) 239(4) 284(1)

Page 561: Instrumental

544

I00 -El"

6O

4O

, o . l ll,,, 19,1 104 12 137

. . . . i . . . . - . . . . , . . . . I . . . . I . . . . I . . . . i . . . . I ,

0

164 OH

CHa

, , , I . . . . I . . . . I . . . . I . . . . I . . . . I " , ' , , , I . . . .

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 1 6 4 ( 1 0 0 ) 1 4 9 ( 4 0 ) 1 0 3 ( 3 5 ) 7 7 ( 3 5 ) 1 3 3 ( 3 5 ) 9 1 ( 3 0 ) 1 3 1 ( 3 0 ) 5 5 ( 2 7 ) 4 1 ( 2 5 ) 1 0 4 ( 2 0 ) 1 2 1 ( 2 0 ) 1 3 7 ( 2 0 )

Page 562: Instrumental

545

100 109

40

20

124

81

. . . . i . . . . . 163 I ~9 . . . . i . . . . . . . . I . . . .

20 40 60 80 100

OH

I

]25 . . . . I . . . . t . . . . i . . . . I . . . . I . . . . I . . . . I . . . . ~ . . . . | . . . .

120 140 160 180 200 220 240 260 280 300

E l : 109(100) 124(77) 81(60) 27(24) 39(26) 53(19) 63(7) 77(12) 79(10) 107(22) 108(21) 125(7)

~20

Page 563: Instrumental

546

100 135 150 .... _

O H 8 0 "

_

6 0 - 91

40 7 7

2 0 51 79 [ 171

- [ !11 ,33

. . . . ; . . . . . . . . . ; . . . . , . . . . ; . . . . , . . . . ; . . . . - . . . . ~ , , , , ~ . . . . ; ,...-,. , , �9 . . . . ; . . . . ; , ,,,,,,, , ; . . . .

0 2 0 40 6 0 8 0 100 120 140 160 180 2 0 0 2 2 0 2 4 0 2 6 0 2 8 0 3 0 0 3 2 0

El: 1 ,50 (100) 1 3 5 ( 9 9 ) 9 1 ( , 5 6 ) 7 7 ( 4 0 ) 1 0 7 ( 3 2 ) 1 1 5 ( 2 9 ) 3 9 ( 2 8 ) 7 9 ( 2 3 ) 5 1 ( 2 1 ) 4 1 ( 2 0 ) 6 5 ( 1 8 ) 1 0 5 ( 1 7 ) 1 1 7 ( 1 3 ) 1 2 1 ( 1 3 ) 1 3 , 3 ( 1 2 ) 6 3 ( 1 1 )

Page 564: Instrumental

547

100 ... m .

-El

80" 91 107

6O 03

I . . . . I . . . . I , ' ' r , , , . . . . , . . . . , . . . . , . . . . , . . . . , ' 0 20 40 60 80 100 120 140

= ,

17g Of , ,

1351147 163

160 180 200 220 240 260 280 300 320 El: 178(100)91(81) 107(72) 103(64) 147(40) 163(40) 72(40) 79(35) 105(28) 135(24)

Page 565: Instrumental

548

100

40

20

55

. . . . ~ . . . . i . . . . , . . . . , , , 20 40 60 80

119

105

1 I

l 204

,I . . . . . . . ~I .... I .... I..I.I,2~ " .... I .... I .... I .... i .... . ....

100 120 140 160 180 200 220 240 260 280 300 320

El: 119(100) 93(65) 105(48) 133(10) 55(48)67(8) 69(30) 77(26) 79(30) 91(36) 134(14) 161(10) 189(3) 204(30)

Page 566: Instrumental

549

11111

40

- E l

II

H "--- OH

H :

,2,, 121

20

137 11164 0 . . . . I . . . . i , ~ , ~ . . . . , . . . . , ~ , , , ', I , , ,~ . . . . I , ,~, ,6, :5 ' , , z v ] , ; 2 2 2 , " i ~ . . . . -

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 43 (100 ) 95 (53 ) 121 (30 ) 41 (20 ) 55 (17 ) 71 (15) 79 (17 ) 81 (16 ) 105(17) 109(18) 137(7) 161(15) 164 (10 ) 189(2) 2044115) 222(3 ) 205(2)

Page 567: Instrumental

550

IO0 -El 8O

4O 20

H

97 /107 161 311 9 95 I 67 1191351 1 lO 204

. . . . i . . . . 1 1 6 9 11211133 162 189

. . . . ~ . . . . ~ . . . . i . . . . ~ . . . . i . . . . ; . . . . i . . . . ; . . . . i !222, ; . . . . i . . . . ; . . . . i . . . . 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 59(90) 41 (100) 31(25) 39 (27) 43(85) 53(12) 55(35) 67(21) 69(10) 77(22) 79(30) 81(30) 91 (41) 93(50) 95 (31) 105(35) 107(47) 109(17) 119(25) 133(13) 135(26) 121(12) 161(43) 162(14) 189(15) 204(20) 222(3)

Page 568: Instrumental

551

iii 1 0 0 -El

I1 H 40

20 5 ! 149

]31 Iti9 ]81 ~s [!~~7 119 I tl ~ , 1 1 6 1 1 2 0 4 1 8 9 t'

0 20 40 60 80 1 O0 120 140 160 180 200 220 240 260 280 300 320 El: 59(100) 43(67) 41(50) 31(17) 55(26) 67(11) 69(19) 81(16) 91(20) 93(20) 95(17) 105(15) 107(20) 109(18) 119(12) 135(12) 133(9) 149(30) 161(20) 189(14) 204(18) 222(4)

Page 569: Instrumental

552

100 -EI

8O

6O

4O

2O ,,,[3,1 ,, , I! 5,

20

$9

I t t 4 i , . . . . l l - ~ I n n J . . . . . . . . . . . . , . . . . w r l I , , ,---~ . . . . I I ,~ -'-'-'-' ~ . . . . ~ . . . .

40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 E l : 59(100) 41(47) 43(50) 53(10) 31(15) 55(20) 67(15) 69(10) 77(11) 79(21) 81(22) 82(16) 91(20) 93(21) 95(18) 105(18) 107(20) 108(23) 109(23) 119(11) 121(14) 123(11) 135(5) 149(14) 161(3) 164(14) 189(3) 204(3) 222(2)

Page 570: Instrumental

553

100 -EI

80

60

40

20

161 204 ( i

43 59 133 1 5 81 91 [

l~l 1~ l 7 5 135 163 205

i i , , , , | , ' , , | " | ~ j ~ . . . . 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 189(100) 204(78) 161(75) 41(73) 59(52) 133(51) 43(54) 81(48) 55(45) 91(45) 123(40) 79(39) 105(37) 93(35) 69(30) 67(30) 107(31) 147(23) 149(21) 77(20) 53(15) 57(15) 135(18) 95(15) 222(5) 205(10) 153(20)

Page 571: Instrumental

554

100

80

40

143

93 123

I 5 19 1161 0 . . . . - . . . . , . . . . ; . . . . . . . . . . . . . . . I . . . . | . . . . I . . . . I . . . . I . . . . , . . . . , . . . . , . . . . -

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

E l : 43 (100 )81 (84 )41 (60 )55 (21 )69 (20 )93 (17 )80 (16 ) 123 (16 ) 71 (14 ) 105 (14 ) 79 (13 )95 (11 )107 (11 ) 109 (11 )53 (10 ) 161 (8 )

119 (8 )

Page 572: Instrumental

555

100 -El

8O

40

20

H ,,,~

,, 41

f43

i1 119

l '~ . . . . i . . . . i , , I . . . . I , , , , . . . . . . t . . . . I . . . . i . . . . t . . . . I . . . . t . . . . t . . . . I , , ' , ,

20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 6 9 ( 1 0 0 ) 4 1 ( 5 4 ) 4 3 ( 4 5 ) 1 1 9 ( 3 7 ) 109 (29 ) 55 (20 ) 6 7 ( 1 6 ) 7 9 ( 1 6 ) 121 (16 ) 8 1 ( 1 2 ) 107 (12 ) 1 2 3 ( 1 2 ) 1 3 7 ( 1 2 ) 1 3 9 ( 1 2 ) 2 0 4 ( 1 2 ) 161 (8 )

Page 573: Instrumental

556

100

80

60

-El

40

zo .-

. . . . i . . . .

20 40 60

91

619 8, ,05 55 79

I I 257 II I 7 '7 2 3 147 229 272

9 7 133 161 175 187 258

~ 59 3 - , , , ~ i . . . . i , i | . . . . i . . . . . . . . . . . . ! . . . . i . . . . . . . . ! . . . . i . . . . . . . . . . . . . . . .

80 100 120 140 160 180 200 220 240 260 280 300 320

El: 39(14) 41(100) 43(26) 53(17) 55(52) 57(17) 69(65) 77(28) 67(38) 79(56) 80(16) 81(65) 82(24) 83(21) 91(83) 92(31) 93(50) 94(24)95(57)96(10)97(14)105(65)106(32) 107(32) 108(17) 109(33) 117(13) 119(31) 120(12)121(15)123(34) 125(43) 131(14) 133(20) 134(11) 137(12) 145(12) 147(34) 148(13) 159(12)161(18) 173(11) 175(18) 187(20)213(26)229(34)257(41)25~ 272(38)

Page 574: Instrumental

5 5 7

100

80

60

40

20

53

' ' I . . . . . . . . . . I , ,

0 20 40 60 80 100

il

109

0

120 140 160 180 200 220 240 260 280 300 320

El: 110(100) 109(87) ~ ( ~ ) 39(13) 51(11) 41(10) 81(8)

Page 575: Instrumental

558

1oo -EI

8O

6O

40 =

39

1143 I10

0

2 O

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: ~ ( 1 ~ ) 110(,~) 39(5O) 43(4O) 67(3O) 68(2O) ~(15) 1 ~1(10) 82(4)

Page 576: Instrumental

559

100 -El

60

29 40 -

20

0 20

126 0

,[ Q1 . . . . , . . . . , . . . . . . . . | . . . . ! . . . . | . . . . i . . . . I . . . . I . . . . I . . . . ! . . . . i . . . . ; . . . . i

40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

E l : 9 7 ( 1 0 0 ) 1 2 6 ( 6 1 ) 6 9 ( 3 0 ) 2 9 ( 4 8 ) 3 9 ( 6 5 ) 4 1 ( 8 7 ) 5 1 ( 1 7 ) 5 3 ( 1 7 ) 8 1 ( 4 ) 1 0 9 ( 9 )

Page 577: Instrumental

560

100

80

60

40

20

-El

85

128

HO 0

0

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 43(100) 57(69) 128(61) 85(39) 55(16) 39(10)

Page 578: Instrumental

561

11111

6 0 "

411"

20"-

, = ,,

-El 43

55

7O

I I I

[lO

I12

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 111(100) ~(96) 42(63) 41(19) ~ ( ~ ) ~(41) 69(11) 7O(26) 82(~ 1) 98(7) ~0(19) 112~

Page 579: Instrumental

562

100

8 0 -

6 0 -

4 0 -

20-

N

J-.s

0 o 20 40 6o so 100 120 140 160 180 200 220 240 260 :zso 300 320

El: 127(100) 71(77) 41(14) 86(73) 85(27) 59(27)

Page 580: Instrumental

563

100 -El " 72 . . . . . . . . . . . . . . .

2 71

144 i

40 45 I TM

- I "/9 10

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 72(100) 71(73) 144(52)45(45) 111(35)39(25) 73(12)97(12) 103(11)69(8) 79(8)

Page 581: Instrumental

564

100

80-

60-

40 -

20 -

0

0

i

55

I 60

59 180

20 40 60 80 100 120 140 160 180 200 220

El: 55(100) 43(78) 45(62) 60(60) 59(47) 180(46) 88(25) 115(25) 64(24) 92(23) 116(20) 182(5)

2 ~ 2 ~ 2 ~ 300 320

Page 582: Instrumental

565

100 I-EI 44

_ 60 59

4 0 -

17 1 - 3 9 i !

0 . . . . i . . . . i . . . . . . . . . . . . I , , , | . . . . ! . . . . l i , , , I . . . . t . . . . t . . . . t . . . . i . . . . , - , , , ,

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 4 4 ( 1 0 0 ) 5 9 ( 4 8 ) 6 0 ( 5 6 ) 7 0 ( 3 0 ) 7 1 ( 2 6 ) 6 9 ( 1 1 ) 1 0 3 ( 1 5 ) 1 6 3 ( 2 6 ) 4 2 ( 2 2 ) 4 3 ( 1 1 )

Page 583: Instrumental

566

40

2 0 -

60

t 124 184

S---S

S----S

0 65 92 186

0 20 40 60 80 100 120 140 160 180 200 220 Z40 260 ZSO 300 320

El: 59(100) 124(30) 184(37) 119(11) 45(15) 60(44) 65(7) 92(7) 186(7)

Page 584: Instrumental

567

104}

80"

60-

40-

20-

m i -El

i ]24

151

I

0 o 2e 40 6o so 100 120 140 160 180 200 220 240 26o z80 300 32e

El: 124(100) 151(20) 166(7) 95(10) 94(16) 125(8) 165(4) 81(11) 53(12) 123(10) 125(8) 54(10)

Page 585: Instrumental

568

100

80

60

40

20

II I!

149 1177

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 136(100) 121(19) 149(15) 177(10) 137(10)41(6)53(6) 135(5) 192(1)

Page 586: Instrumental

569

Chemiegl name: 2-(5'-HYDROXYMETHYL-2'-FORMYLPYRROL-I'-YL)-3-PHENYLPROPIONIC ACID LACTONE N ~ 4829

Origin & ref: GLUC.-PHENYLALANINE MODEL SYSTEM;VERNIN et aI.,INSTR.ANAL. OF FOODS,ELSEVIER,1982,97.

Molecular formul C15 HI3 03 N1 (255) ILN (CAS): 60026 28 0 CA:

IKA: 0 IKP: 0 DIK 0 Family: Heterocycles Pyrroles FEMA: 0 COE 0 IOFI 2

Descriptor odor/Flavor TOBACCO,CHOCOLATE-LIKE / IDEM

100 -EI 91

80 t ~ ~ C H O

4O 0

20 39 1 1255

0 ~ . . . . . . . . ~ . . . . I . . . . | . . . . t . . . . , , I t . . . . I , ' ~ , , , . . . . ~ . . . . r . . . . ~ . . . .

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

El: 91(100)255(22)39(9)51(4)65(13) 77(4) 78(4) 108(13) 120(9) 131(9) 136(4) 147(4) 148(4) 164(4)210(4)211(4) 256(4)

Page 587: Instrumental

570

4. REFERENCES

1. Petitjean M, Vernin G, MetzgerJ. In: Charalambous G, Inglett G, eds. Instrumental Analysis of Food: Recent Progress, Academic Press, New York: 1983: Vol. 1: 97-123. Petitjean M, Mass spectra and Kovats indices data bank of flavoring heterocyclic compounds (in French), Thesis Sciences, University of Aix- Marseilles III ,1982. Vernin G, Petitjean M. In: Vernin G, ed, The Chemistry of Heterocyclic Flavouring and Aroma Compounds., Ellis Horwood Publ., Chichester, England: 1982; 305-342.

4. Vernin G, Petitjean M, Metzger J. Parf. Cosm. Ar6mes 1983: 51: 43-51. 5. Vernin G, Petitjean M, Poite JC, Metzger J, Fraisse D, Suon KN. In:

Vernin G, Chanon M, eds. Computer Aids to Chemistry, Ellis Horwood Publ., Chichester, England: 1986; 294-333.

6. Vernin G. Le point sur la banque de donn~es SPECMA, flaveurs et fragrances, Parf. Cosm. ArSmes 1985; 66" 27.

7. Vernin G, Petitjean M,, Poite JC, Metzger J. In: Sandra P, Bicchi C, eds. Capillary Gas Chromatography in Essential Oil Analysis, Huethig Verlag Publ. Heidelberg: 1987; 287-328,

8. Vernin G, Boniface C, Metzger J. Analusis 1987:15 : 564-568. 9. Adams R. In: Identification of Essential Oil Components by GC/ITMS,

Academic Press, New York: 1992; Allured Publ. Co, 1995. 10. McLafferty FW, Stauffer DB. Mass Spectrometry Library Search System

Bench Top PBM version 3.0, Palisade 10, Newfield, New York: USA, 1993; idem ; The Wiley/NBS.

11. Hennberg D, Wilmann B, Joppek W. MPI Library of Mass Spectral Data, Max-Planck Institut fur Kohlenforschung, M01heim: Ruhr, Germany: 1994.

12. Ten Noever de Brauw MC, Baumann J, Gransberg LM, La Vos MGF. In: Compilation of Mass Spectra of Volatile Compounds in Food, 1988-1996; Vol. 1-16; TNO Nutrition and Food Research, P.O. Box 300, 3700 A.J. Zeist: The Netherlands.

13. National Institute of Standards and Technology, PC Version of the NIST/EPA/NIH Mass Spectral Data Base, Version 4.5, US Dept. of Commerce,Gaithersburg, USA: 1994.

14. Colon F. SPECMA 2000 data bank, Thesis Sciences, University of Aix- Marseilles III (to be presented) 1997.

15. Allured's Flavor and Fragrance Materials. Worldwide reference list of Materials used in compounding flavors and fragrances, Allured Publ. Co.362 Schmale Road, Carol Stream, IL 601 188-2787 USA: 1996.

16. Arctander S. Perfumer and Flavor Materials, Montclair, N J: 1969. 17. Furia TE, Bellanca N. eds. Fenaroli's Handbook of Flavor Ingredients, 2nd ed.

CRC Press, Cleveland, Ohio, USA: 1975. 18. Van Gemert CJ, Nettenbreijer AH. eds. National Institute for Water Supply,

Central Institute for Nutrition and Food Research, TNO, A.J. Zeist, The Netherlands: 1977.

.

,

Page 588: Instrumental

571

19. S. Fors, In: Waller GR, Feather MS, eds. The Maillard Reaction in Foods and Nutrition, ACS Symposium Series, 1983: 215; 185-286.

20. Bauer K, Garbe D. Common Fragrance and Flavor Materials, VCH-Verlags- Gesellschaft, Weinheim, Germany: 1985.

21. Takahashi A, Akiyama H. In: Charalambous G, ed. The Shelf-life Studies of Foods and Beverages, Elsevier, Amsterdam: 1993: 33: 1003-1032.

22. Calkin RR, Jellinek JSt. eds. Perfumery, Practice and Principles, Wiley J and Sons, New York, Chichester: 1994.

23. IFF International Flavors and Fragrances Inc. Perfumes compendium 4th ed. World Headquarters, 521 West 57th Street, New York 10019: 1995.

24. Aldrich, Flavors and Fragrances, International Edition, 1101 West St-Paul Avenue, Milwaukee, Wisconsin, 53233, USA: 1996.

25. Schnabel KO, Beliz HD, Von Ranson C. Z. Lebensm. Unters. Forsch 1988: 187:215-223.

26. Chastrette M, Cretin D, El A'(di Chafei. J. Chem. Inf. Comput. Sci 1996: 36: 108-113 and references cited therein.

27. Vernin G, Metzger J, Fraisse D, Scharff C. Parf. Cosm. Ar6mes 1983: 52" 51-61.

28. Fraisse D, Scharff C, Vernin G, Metzger J. IXth Int. Congres Essential Oils, Singapore: 1983. Essential Oils Technical Paper, 1983: Book 3: 100-120.

29. Vernin G, Chakib S. Geranium essential oils from Morocco (Unpublished results ).

30. Vernin G, Metzger J, Fraisse D, Suon KN, Scharff C. Perfumer Flavorist 1984: 9; 71-86.

31. Vernin G, Boniface C, Metzger J, Ghiglione C, Hammoud A, Suon KN, Fraisse D, Parkanyi C. Phytochemistry 1988: 27: 1061-1064.

32. Vernin G, Metzger J, Suon KN, Fraisse D, Ghiglione C, Hammoud A, Parkanyi C. Lebensm. Wiss u. Technol. 1990: 23: 25-33.

33. Vernin G, Faure R, Pieribattesti J.C.J. Essent. Oil Research 1990: 2(4): 211- 214.

34. Vernin G, Metzger J, Mondon JP, Pieribattesti JC. J. Essent. Oil Research 1991 : 3:197-207.

35. Vernin G. J. Essent. Oil Research 1991:3: 49-53. 36. Vernin G, Merad O, Vernin GMF, Zamkotsian RM, Parkanyi C. In:

Charalambous G. ed. Food Flavors: Generation, Analysis and Process Influence, Elsevier, Amsterdam: 1995: 37A: 147-205.

37. Vernin G, Merad O. J. Essent. Oils Research 1994; 6: 437-448. 38. Vernin G, Colon F. Roman Camomile (Anthemis Nobilis) essential oil (to be

published). 39. Vernin G. Poite JC. Everlasting (Hefichrysum Stoechas) essential oil (to be

published). 40. Vernin G, Metzger J. Perfumer and Flavorist 1986; 11 : 79-84. 41. Vernin G, Metzger J, Fraisse D, Scharff C. Planta Medica 1986; 96-101. 42. Randriamiharisoa R, Gaydou EM, Bianchini JP, Vernin G. Sciences des

Aliments 1986: 6:211-231.

Page 589: Instrumental

572

43. Vernin E, Pujol L, Vernin G, Vernin GMF, Metzger J. Parf. Cosm. Ar6mes 1989: 89:81-94.

44. Vernin C, Vernin G, Vernin GMF, Metzger J, Pujol L. Parf. Cosm. Ar6mes 1990: 93: 85-90.

45. Vernin G, Metzger J. In: Linskens HF, Jackson JF. eds, Modern Methods of Plant Analysis, Essential Oils and Waxes, Springer Verlag, Berlin, Heidelberg: 1991: Vol 6: 6; 99-130.

46. Vernin G, Metzger J, Azzario P, Barone R, Arbelot M, Chanon M. In: Charalambous G. ed. Recent Developments in Food Science and Human Nutrition Elsevier SC. Publ. 1992; 75-97.

47. Vernin G, Petitjean M, Metzger J. Tarragon essential oil (See Ref. 7). 48. Vernin G, Parkanyi C. In: Charalambous ed. Spices, Herbs and Edible Fungi,

Elsevier, Amsterdam: 1994; 34: 329-346. 49. Vernin G, Vernin C, Metzger J, Pujol L, Parkanyi C. In: Charalambous ed.

Spices, Herbs and Edible Fungi, Elsevier, Amsterdam: 1994: 34:411-426. 50. Vernin G, Metzger J, Parkanyi C. In: Charalambous ed. Spices, Herbs and

Edible Fungi, Elsevier, Amsterdam: 1994: 34: 457-468. 51. Vernin G, Gighlione C, Parkanyi, C. In: Charalambous ed. Spices, Herbs and

Edible Fungi, Elsevier, Amsterdam: 1994: 34: 483-500. 52. Vernin G., Vernin E, Metzger J, Pujol L, Parkanyi C. In: Spices, Herbs and

Edible Fungi, Elsevier, Amsterdam: 1994: 34: 501-578. 53. Vernin G, Parkanyi C. In: Spices, Herbs and Edible Fungi, Elsevier,

Amsterdam: 1994; 34: 579-594. 54. Vernin G. ed. The Chemistry of Heterocyclic Flavouring and Aroma

Compounds, Ellis Horwood Publ. Chichester, England: 1982. 55. Vernin G, Boniface C, Metzger J, Obretenov T. Kantasubrata J, Siouffi A,

Larice JL, Fraisse D. Bull. Soc. Chim. France 1987: 4: 681-694. 56. Vernin G, Metzger J, Obretenov T, Suon KN and Fraisse D. In: Lawrence BM,

Mookherjee BD, Willis BJ. eds. Flavors and Fragrances: a World Perspective, Elsevier, Amsterdam: 1988; 999-1028.

57. Debrauwer L, Vernin G, Metzger J, Siouffi AM, Larice JL. Bull. Soc. Chim. France 1991 : 128: 244-254.

58. Vernin G., Metzger J, Boniface C, Murello MH, Siouffi AM, Larice JL, Parkanyi C. Carbohydrate Research 1992: 230: 15-29.

59. Vernin G, Debrauwer L, Vernin GMF, Zamkotsian RM. In: Charalambous G. ed. Off Flavours in Foods and Beverages, Elsevier Sci. publ. 1992: 28: 567-623.

60. Vernin G. Metzger J, Sultan AM, EI-Shaffei A.K, Parkanyi C. In: ACS Symposium Series, Molecular Approaches to the Study of Food Quality, Amer. Chem Soc. Washington DC: 1993; 36-55.

61. Vernin G. Metzger J, Suon KN, Fraisse D. Parf. Cosm. Ar6mes 1985: 62: 69- 74.

62. Vernin G, Bouin D, Metzger J, Fraisse G, Scharff C. In: Charalambous G. ed. The Shelf-life of Foods and Beverages, Proceedings of the 4th Int. Flavor Conference, Elsevier, Amsterdam: 1986: 12: 255-284.

Page 590: Instrumental

573

63. Vernin G, Vernin E, Vernin C, Metzger J, Soliman A. Flavour and Fragrance J. 1991: 6: 143-148.

64. Vernin G, Vernin GMF, Metzger J, Roque C, Pieribattesti JC. J. Essent. Oil Research 1991 : 3: 49-53.

65. Vernin G, Vernin C, Roque C, Pieribattesti JC. GC/MS analysis of volatile components of Psidium Cattleianum Sabine fruit from Reunion island, submitted for publication.

66. Vernin G., Boniface C, Metzger J, Fraisse D, Doang D, Alamercery S. In: Charalambous ed. Frontiers of Flavors, Elsevier, Amsterdam: 1988: 17: 655- 685.

67. Vernin G, PascaI-Mousselard H, Metzger J, Parkanyi C. In : Charalambous ed. Shelf-life Studies of Foods and Beverages, Elsevier, Amsterdam: 1993: 33: 975-990.

Page 591: Instrumental

This Page Intentionally Left Blank

Page 592: Instrumental

D. Wetzel and G. Charalambous (Editors) Instrumental Methods in Food and Beverage Analysis �9 1998 Elsevier Science B.V. All rights reserved

CAPILLARY ELECTROPHORESIS FOR FOOD ANALYSIS

575

Custy F. Femandes and George J. Flick, Jr.

Department of Food Science and Technology, Virginia Tech, Blacksburg, VA 24061-0418

1. INTRODUCTION

1.1 Basic Elements

The capillary electrophoresis methodology combines column chromatographic and gel electrophoretic

techniques. Fig. la, represents the basic elements of a capillary electrophoreUc system in its simplest form.

The separation is performed in a capillary filled with a carrier electrolyte and loaded with analyte. Following

application of an electrical energy at both ends of the capillary, the analyte migrates and is detected by the

detector (fig. lb).

Fig. la. Basic elements of a capillary electrophoretic system.

Page 593: Instrumental

576

1.1.1 Capillary

The industrial production of a narrow internal diameter (d) (ca. 10-100 pm), polyimide coated (ca. 15

pm thick t') fused silica capillary resulted in rapid developments and extensive applications of the capillary

electrophoretic technology. The fine diameter capillary is essential to dissipate Joule heating. The polyimide

coating reduces the fragility of the fused silica capillary. The capillary is characterized by the effective (L,) and

total ~ lengths (fig. la). The I_, is the distance between the injector and detector, while l-t is the entire length

of the capillary across which the electrical voltage is applied. For on-capillary detection (e.g., optical

spectroscopy), the L, is generally less than It. For off-column detection (e.g., mass spectrometry) the I-t and

L~ are equal.

1.1.2 Electrolytic Vessels

Submerged in each electrolytic vessel (reservoir) is the capillary filled with a carder electrolyte. The

vessels are characterized as anodic (injector-end) and cathodic (detector-end) electrolytic vessels. The

Fig. lb. Operating capillary electrophoretic system during spearation with injector end anodic vessel

(left) and detector end cathodic vessel (right).

Page 594: Instrumental

577

electrolytic vessels and the capillary contain an identical electrolyte, it is essential to fill the electrolytic vessels

to same level. Thus reducing the imbalance due to hydrostatic flow.

1.1.3 Electrical Source

An electrode immerses in each electrolytic vessel. The electrical energy for separation is supplied

through the electrodes. A direct current power regulator with an output voltage (ca. 5-50 kV) and current (ca.

0.5-1.0 rnA) ranges is generally used. The applied electrical field strength (E in V/m) is the ratio of the applied

voltage (V in V) to total length of capillary. The electrical field strength facilitates comparison between

capillaries of different length.

E = V/I.~ [V/m] (1)

1.1.4 Sample Application

A sample is loaded by exchanging the anodic (injector-end) electrolytic vessel with the sample vessel.

Generally, minuscule quantity (ca. 5-10 qL) of the sample is loaded at the anode (injector-end) either,

electrokinetically or hydrodynamically. The electrolytic vessel replaces the sample vessel and separaUon is

initiated within the capillary following application of electrical energy.

1.1.5 Detector

The detector detects the analyte as it migrates to the cathode. An analyte can be detected at

femtomole concentration (one fM is 10 "15 M). An optical detector is frequently used.

1.2 Basic Electrophoretic Principle

Suppose a sample (e.g., two cationic analytes) is subjected to capillary electrophoretic separation. The

two cationic analytes are loaded at the anode and an electrical voltage (V) is applied across the fused silica

capillary of total length (I-t). Both analytes will migrate from the anode to the cathode, through the detector.

The analyte migration time (t=) is the interval between the electrophoretic initiation and detection. The analyte

migration distance is the effective length (L,) for on-capillary detection. The electrophoretic velocity (V,~) is

expressed as:

Page 595: Instrumental

578

V,, =l_Jt, [m/s] (2)

The electrophoretic mobility (p.,) rather than the electrophoretic velocity is preferred, because it

facilitates comparison between electropherograms. The relaUonship between electrophoreUc mobility and

velocity is given by:

p,~ = Vo,/E = L,/Et, [m2Ns] (3)

The electrical (F,) and frictional (F=) forces are given by the eq. (4) and (5). respectively. The observed

mobility is determined by equating the electrical force on the ionic analyte with the frictional drag through the

medium:

F. = q=E

Ff = 3nq=,d=V,,

from eqs. 4 and 5

q,E = 3nq=,d,V,~,

or

[CV/m] (4)

[Kgm/sZJ (5)

p,~ = q,/3nq=,d=V,~ [m2Ns] (6)

Where rl=, is viscosity of carrier electrolyte

d= is stokes diameter of ionic analyte

q= is analyte charge

[Poise] or [kg/ms]

[m]

[Coulomb] or [C]

The observed mobility (Pob=) of the analyte is constant in a defined electrolytic environment and

facilitates comparison between electropherograms. The observed mobility is the summaUon of electrophoretic

(p~ and electroosmotic (P,of) mobilitJes.

Page 596: Instrumental

579

or

Pob, -- I_JEt, + q,/3nn.d,V.p

(7)

(8)

1.2.1 Electroosmotic Flow

The wall of the fused silica capillary is caUonic at most pH conditions. There is a built-up of anionic

countedons in the solu'don adjacent to the capillary wall. Under the influence of the applied electrical field, the

anions are drawn toward the cathode, resul'dng in the bulk flow of electrolyte toward the cathode. The bulk flow

of carrier electrolyte under the influence of an electric field is termed "electroosmoUc flow" (EOF). The

magnitude of the EOF depends on the consb'u~on of the capillary and the electrolytic environment. A capillary

constructed with a nonionic material (e.g. Teflon) exhibits slow EOF (ca. pH 3-5), whereas an ionic material

(e.g., fused silica) shows a fast EOF (ca. pH 6-8) (see Fig. 2). The direction of the EOF can be modulated by

altering the internal charge (e.g., ionic or nonionic) of the capillary wall. During coelectroosmotic

electrophoresis (Po~ = P~ + P~), the electroosmoUc and electrophoretJc mobil~es migrate the analyte in the

same direction. While, in counterelectroosmotic electrophoresis (Pob, = I~p - ~ ), the electroosmotic and

electrophoretic mobilitJes migrate the analyte in the opposite direction.

1.2.1.1 Zeta potential

The zeta potential (Z) results due to the electrical double layer. The electrical double layer develops

between the internal charge on the capillary wall and the charged carder electrolyte. The internal surface of

a fused silica capillary is anionic due to the ionization and/or adsorption of cations. The ionization (major

contdbuUon) of the silanol groups (SiO) and adsorption (minor contribution) of cations is responsible for the

anionic surface. The ca~ons in the carder electrolyte buildup and equilibrate the anionic surface. The electrical

double layer generates a potential difference near the capillary wall and is termed zeta potential.

Under the influence of an electrical field, the cations contribu~ng to the double layer migrate to the

cathode. The solvated cations drag the electrolytic fluid in the fused silica capillary toward the cathode. The

relationship between electroosmotic velocity and zeta potential is expressed by the Smoluchowske equation

Page 597: Instrumental

580

v ~ = E(~_/nJ (9)

or

p,~ = ~Z/q=, (10)

where ~ is dielectric constant of cartier electrolyte

The zeta potential is influenced by capillary characteristics (surface charge) and carder electrolyte

composition (ionic concentration and strength) but independent of applied electrical field. The zeta potential

is primarily due to the charge on the internal wall of the capillary. The pH, of the carrier electrolyte, modulates

the charge on the surface as well as the charge and mobility of the analyte. For fused silica capillary the eof

increases with pH. This is because the silanol groups ( -SiO "1) and analytes are deprotonated at high pH and

vice-versa at low pH (fig. 2) (Lukacs and Jorgenson, 1985) [K. D. Lukacs and J. W. Jorgenson, 1985. J. High

Res. Chrom pg. 407-411]. The zeta potential is an inverse function of the ionic strength of the cartier

electrolyte. Increasing ionic strength reduces the electrical double-layer and lowers zeta potential.

1.3.1 Flow Profile in Capillary

Fluids flow due to the pressure difference between the ends of a capillary tube and a parabolic or

laminar (NR~ Reynolds number < 2000) fluid flow profile develops due to the shear forces at the capillary wall.

However, a fiat flow profile is observed in a narrow bore fused silica capillary during electrophoretic separation

(fig. 3), a uniquely desirable feature. Additionally, there is no pressure drop (or hydrostatic imbalance) across

the capillary. Therefore, the driving force for the carrier electrolytic fluid is the EOF. The flat flow is nearly

uniform throughout the capillary and limits analyte zone dispersions. However, a thin quiescent electrolytic

layer extends a short distance into the bulk of the electrolytic fluid. This arises due to frictional forces against

the bulk fluid flow at the wall. The fluid velocity reduces rapidly at the wail. The frictional forces in the thin

quiescent electrolytic layer are small compared to the other dispersive forces that contribute to the overall

separation process. Additionally, the fluid velocity and flow profile are generally independent for a narrow bore

capillary (d= < 10-100 pm). In a wide bore fused silica capillary ICd �9 200-300 pm), the fluid flow profile is

affected.

Page 598: Instrumental

581

f PEoFXl0~(cm2Ns) 5 -

Pyrex

Teflon

Silica

\

t t t ' I , t I 2 3 4 5 6 7 8

pH

Fig. 2. Electroosmotic f low (EOF) as a function of pH for different capillaries.

Fig. 3. Illustration of flat f low profile during electrophoretic separat ion with narrow bore fused silica

capillary.

Page 599: Instrumental

582

1.3.2 Flow direction in Capillary

Generally, under the influence of EOF all analytes migrate in the same direction and independent of

their charge. However, some exceptions are encountered. For fused silica capillary, the eof is from the anode

to the cathode. An anionic analyte migrates toward the cathode, as its electrophoretic mobility is smaller than

the electroosmolJc mobility. A mixture of three analytes (anionic, cationic and neutral) can be electrophoresed

in a single run. All analytes will migrate toward the cathode (fig. 4). The anionic analyte migrates the slowest

(Po=, = P,~ - IJ.p), because the electrophoretic mobility directs it to the anode but the electroosmotic mobility

carries it to the cathode. The neutral analyte migrates at EOF (Po=, = P.~). The cationic analyte migrates the

fastest (IJo=, = P,of + Pop), because the electrophoretic and electroosmotic mobilities are in the same direction.

If the magnitude of the electrophoretic mobility exceeds the electroosmotic mobility, then the anionic and

cationic analytes, migrate to their respectwe electrodes. Further, alteration of capillary wall charge can reduce

or eliminate EOF without influencing the electrophoretic mobility of the analyte. In such situations, cationic and

anionic analytes migrate to the cathode and anode, respectively. This has been observed for small ions (e.g.,

Na § K *1, C1-1, F-l).

1.4 Factors influencing EOF

In a fused silica capillary, the EOF increases with pH (fig. 5). At rapid EOF (e.g., high pH), analytes are

eluted without resolution. On the other hand, at slow EOF (e.g., low pH) the anionic fused silica capillary wall

will adsorb calJonic analytes through coulombic interactions. Under such conditions, separation or desorption

of analytes can be obtained through alteration of capillary characteristics (e.g., surface), carrier electrolyte

composition (e.g., viscosity) and/or operational parameters (e.g., electrical field strength). The EOF is directly

related to electrical field strength. Therefore EOF can be reduced by lowering the electrical field strength.

However, low field strength reduces efficiency as well as resolution and increases analyte retention time.

Pragmatically, the best approach is to reconstitute the carrier electrolyte pH. The zeta potential is altered by

carder electrolyte compos~on (e.g., ionic strength and concentration). Adjusting the pH can affect the charge

and mobility of the analyte. Low pH buffers protonate the capillary surface and the analyte, while the contrary

is true of high pH buffers. The pH of the carrier electrolyte can be selected based on the isoelectric point of

analyte (e.g., protein). Higher buffer concentration and ionic strength have been used to affect EOF. At high

Page 600: Instrumental

583

Fig. 5. Increased resolution of analytes with low pH gradient.

Page 601: Instrumental

584

buffer concentration, the coulombic interactions between the analyte and the capillary wall decrease the net

surface charge. A high ionic strength generates high current and additional Joule heating, thus limiting the

modulation of the EOF rate. While, low ionic strength results in adsorption of the analyte. The addition of

organic modifiers (eg. methanol, acetonitdle, trifluroacetic acid) to carder electrolyte alters the zeta potential

and viscosity. Temperature (an operational parameter) affects the viscosity of the carder electrolyte. Joules

heating lowers the viscosity of the carrier electrolyte.

1.5 Dispersion

The analyte zone spreading or broadening is termed as dispersion. Although, many factors influence

dispersion, it is principally due to the longitudinal diffusion along the capillary axis and little or no effect due to

radial diffusion. Other factors contributing to dispersion include the adsorption of analyte on the internal wall

of capillary, sample injection volume, Joule heating, anticonvective properties of capillary, and differences in

analyte mobilities within that zone. Dispersion should be controlled because it increases zone length as well

as the difference necessary for resolution. For a Gaussian peak the baseline peak width (w=) is:

wb = 4 0 [m] (11)

where o standard deviation of peak [m]

by:

The efficiency is expressed as the number of theorelJcal plates (N). For on-capillary detection it is given

N = (l_Jo) 2 (12)

During capillary electrophoresis, there is molecular diffusion (D=), which leads to peak dispersion and

it is expressed as:

o == 2O=t= = 2O,(L,l_~p,,)

where D= is analyte diffusion coefficient [m2/s]

(13)

Page 602: Instrumental

585

The dispersion (o~, is affected inversely by electric field strength and directly by diffusion coefficient.

Generally, the diffusion coefficients are inversely related to molecular weights. Thus, macromolecules (e.g.,

polypepUdes, polynucleoUdes, polysaccharides) will disperse at a lesser extent than micromolecules (e.g.,

amino acids, nucleotides, monosaccharides). Therefore, macromolecules will generate the highest number

of theoretical plates. When an analyte is subjected to a high electric field, it will migrate rapidly through the

fused silica capillary leaving little or no time for dispersion.

1.5.1 Electrodispersion

Electrodispersion is due to difference in sample and carrier electrolyte conductivities. Electrodispersion

results in, skewed peak shapes, analyte focusing (low conductivity), defocusing (high conductivity), and

temporary isotachophoresis. When the conductivities are equivalent electrodispersion does not occur.

However, when the conductivities are mismatched electrodispersion occurs. If the analyte zone has a higher

mobility than the running buffer, the leading edge of the analyte zone will be diffused and the trailing edge

sharp. Conversely, when the analyte zone has a lower mobility than the running buffer, the leading edge will

be sharp and the trailing edge diffused.

When the analyte zone has a higher mobility (e.g., higher conductivity, lower resistance) than the carder

electrolyte, the front edge of the analyte zone encounters a higher voltage drop as it enters the buffer zone.

This causes the diffusing analyte to accelerate away from the analyte zone and results in zone fronting. As the

analyte at the trailing edge diffuse into the carder electrolyte they also encounter an increase in voltage drop,

but in the same direction of migration, and accelerate back into the analyte zone, keeping the trailing edge

sharp. Electrodispersion has no effect on neutral analytes.

Although electrodispersion always occur, it is smaller than other dispersive effects (e.g., diffusion).

Dispersion is particularly evident in a sample containing analytes with a wide ranges in mobilities.

Electrodispersion can be overcomed by matching the conductivities of the sample and the carder electrolyte.

1.6 Joule heating

Joule heating (capillary temperature elevation) is a consequence of the resistance of the carrier

electrolyte to the current flow. Traditionally, the progress in applications of capillary electrophoresis was

Page 603: Instrumental

586

impeded due to use of wide bore diameter capillary. The development of narrow-bore diameter capillary

accelerated the development of capillary electrophoretic technique.

The extent of Joule heating developed is the difference between electrical energy input and thermal

energy dissipated. If all the electrical energy is dissipated then there is no Joule heating effect (no rise in

temperature). This is possible at very low electrical field strength. Normally, high electrical field strength is

applied across the capillary. Under such conditions the electrical energy (ca. 0.5-5.0 W/m) is converted to

thermal energy (ca. 10 K temperature rise). The quantity of heat dissipated is determined by capillary

dimensions and buffer conductivity.

The rate of heat generation in a capillary can be approximated as:

dQ/dt = IV/Al..t = K=o (V/I~)2 = K. (E) 2 [w/m3s] (14)

since I = V/R. & R=. = I_~,A

where R=, is the resistance of the carrier electrolyte

A is cross sectional area of capillary

[ohms]

[rn ~]

Two major problems associated with Joule heating are a radial temperature gradient and temperature

changes with Ume due to ineffective heat dissipation. Other associated problems include viscosity changes,

analyte mobility, analyte zone dispersion, analyte migrational time, and disproportionate increase in EOF.

The Joule heating is problemaUc because it gives rise to radial temperature gradient. The temperature

along the capillary axis is higher than the capillary wall temperature. The temperature gradient results in

viscosity gradient. Since temperature change (ca. I~ affects the viscosity (ca. 2-3%) and mobility (ca. 2-3%),

temperature control is critical.

Joule heating can be influenced by capillary design. The temperature difference depends on the

thermal properties (K=p,,,~, K~y,,~,, hc=pa,ary ) and dimensions (d= and do as well as polyimide coating thickness

1') of polyimide coated fused silica capillary. Although the polyimide coating is ca. 15 pm thick, its low thermal

Page 604: Instrumental

587

conductivity significantly limits heat transfer. A capillary with a narrow d~ and large do dissipates heat readily.

The high ratio of inner surface area-to-volume facilitates Joule heat dissipation. A large do is beneficial due to

a reduction in the insulalJng properties of the polyimide and improves the surrounding heat transfer. A dramatic

decrease in temperature difference can also be realized by reducing the capillary d,. A wide range of capillary

dj are used. Problems encountered with small capillaries (ca. 10-25 IJm (;I) include clogging, detection and

sample loading. Medium size capillary (ca. 25-50 pm d~ are practical. Clogging problems are significantly

reduced by filtering carrier electrolyte through small pore size filters (ca. 0.2 um).

Theore~cally, Joule heating can be controlled by adjusting the operational parameter (e.g., electrical

field strength) and carder electrolyte formulations (e.g., ionic strength). Temperature gradient is directly

proportional to applied electrical energy. Therefore, a reduction in temperature gradient can be obtained by

performing capillary electrophoresis at lower field and ionic strength. These measures are useful but limit

capillary efficiency and performance.

Most of the capillary electrophoretic separations are performed at high electrical field strength and

Joules heating is often encountered. The amount of Joule heating that can be dissipated with design and

optimization of operational parameters and electrolyte concentration is limited. Hence, Joule heating is

dissipated by additional instrumentation. Regulating the capillary temperature enables heat dissipation and

holding the capillary temperature constant.

1.7 Sample LengthNolume

A small sample length/volume is desirable. An increase in sample plug length increases diffusion and

reduces resolution. The sample volume/length depends on the diffusion coefficient (i.e., analyte molecular

weight) and migrational time. The diffusion coefficient of macromolecules (e.g., proteins) is smaller than

micromolecules (e.g., amino acids). The capillary dimension is another important factor in sample

length/volume. Generally, sample injection length is ca. 2% of the L~. For a narrow bore fused silica capillary

ca. 1.0 m Lt and 40 pm ql this corresponds to 20 mm sample length and 5 pL sample volume. Although

modem sample delivery systems can reproducibly deliver such small quantities, analyte detection limits often

necessitate longer injection lengths.

1.8 Analyte Adsorption

Page 605: Instrumental

588

One would expect that the capillary electrophoretic separation of macroanalytes (e.g., proteins) would

yield high efficiencies due to their low diffusion coefficients. However, analyte adsorption on the fused silica

capillary internal wall decreases the performance. A decrease in performance results in peak tailing or total

analyte adsorption. The analyte adsorption on the fused silica capillary walls is primarily due to strong ionic

forces (e.g., cationic analyte and anionic capillary wall), and weak hydrophobic forces. Generally, protein

adsorption on the capillary wall is due to coulombic (ionic) and van der Waal (hydrophobic) forces. While a

large surface area-to-volume ratio of the fused silica capillary is preferred to dissipate Joule heating, a small

ratio is required to minimize adsorption.

Analyte adsorption on the capillary wall surface can be reduced by altering the carrier electrolyte

composition. This measure reduces the coulombic forces. A high ionic strength of carrier electrolyte reduces

the surface charge and analyte adsorption. The reduction in surface charge lowers the zeta potential and the

EOF, resulting in an increase in analyte migration time. The adverse effect of high ionic strength, is Joule

healing (due to increased current). An alternative strategy is to use zwitter ionic carrier electrolytes (e.g., TRIS,

MES, CHAPSO). Electrophoretic separation at pH extremes effectively reduces coulombic forces. At low pH

(ca. < 3) the electrical double layer is reduced as the protonated silanol groups (of fused silica capillary) are

non-ionic. This reduces the EOF and the cationic proteins will migrate slowly towards the cathode. An adverse

effect of this approach is protein denaturation due to low pH as well as precipitation of plant and milk proteins.

At high pH (ca. > 9), both the analyte and capillary wall are anionic (due to deprotonation) and the analyte

adsorption is limited by coulombic repulsion.

1.9 Capillary Wall Modification

The intemal wall of the capillary is altered to reduce adsorption of analyte. Two basic approaches are:

a) permanent modification by covalently bonded or physically adhered phases; and b) dynamic deactivaUon

through incorporation of carder electrolyte additives (e.g., hydrophilic polymers or detergents). Both methods

eliminate or reverse the surface ionic charge, vary hydrophobic forces and limit nonspecific adsorption. The

two methods are beneficial, but neither method has a disUnct advantage.

1.9.1 Permanent coating

Page 606: Instrumental

589

Permanent coating (e.g., covalent bonded or physically adhered phases) can be accomplished with

various functional groups. Silylation followed by permanent coating with a suitable funclJonai group is the most

widely used approach. The EOF is eliminated or reversed by permanent coating. Neutral functional groups

(e.g., polyacn/lamide or polyethylene glycol) eliminates EOF. This results from both decreased surface charge

and increased viscosity at the wall. Cationic functional groups reverses the eof. Amphotedc functional groups

(e.g., proteins, amino acids) yield reversible EOF depending on the pl of the coating and carder electrolyte pH.

The permanent coating of choice is the one that requires little or no maintenance and is stable during

regeneration and hydrodynamic flow. Unfortunately, the stability of most permanent coatings is limited. The

siloxane bond (Si-O-Si) has limited stability (ca. pH 4-7) and hydrolysis limits long term stability.

1.9.2 Dynamic coating

Stability problems encountered in permanent coating are overcome with dynamic coating. Dynamic

coating has been achieved with the addition of modifiers to the carder electrolyte. An advantage of dynamic

coating is stability. A dynamic modifier repeatedly regenerates the coating and dynamic stability is attained.

The dynamic modifier coats the wall and alters coulombic and hydrophobic forces. Dynamic modifiers are

easily incorporated by dissolution in the carder electrolyte and their concentration can be readily optimized.

Dynamic coatings with cationic surfactants (e.g., CTAB) reverse the EOF. There are some drawbacks due to

dynamic coating. These include pH extremes, solutes as well as capillary surface are affected (e.g., SDS

denatures proteins), long regeneration time needed to obtain a reproducible coating and constant EOF.

1.10 Resolution

The resolution is of paramount importance in separational science. The maximum efficiency in

capillary electrophoresis is achieved during coelectroosmosis. Only then is the mobility contribution to the

separation efficiency maximized. However, the optimization of capillary electrophoretic separations is made

more complicated by a divergence of optimal conditions for separation efficiency (N) and resolution (R). The

resolution efficiency of two analyte zones is:

R = 0.25 (N)'~(~v/v) (15)

Page 607: Instrumental

590

where Av/v is the relative migration velocity of the two analyte zones (denoted by subscripts I and 2)

~v / v = ( p o . , - p o . 9 / p o = . v . . . = (p . , , - p . , ~ ) / ( p , ~ . . . , . + p.~)

Po==l = P~I + P~

Po~ = P..= + IJ.of

(~6)

(17)

(18)

From eq. (16) p~ and P.o, inversely affect the magnitude of relative velocity for any given peak pair.

A decrease in relative velocity reduces the resolution (R). Fortunately, this is only valid when the inherent

electrophoretic and electroosmotic mobilities are the only contributions to the po..

N=(l/o)�89

o==2D=t==2D=LL~/p.,V

t= = L/Vo.= L/p.,E= LI.t/p.pV

(19)

(20)

Eqs. 19 and 20 indicate that increasing the voltage is a limited means to improving resolution. To

improve the resolution by two folds, the voltage must be quadrupled. However, Joule heating is oRen the

limitation to increasing voltage. The resoluion can be increased by increasing ~p,~,.

2. MODES OF CAPILLARY ELECTROPHORESIS

Capillary electrophoresis comprises a group of techniques that have different operative and separative

characteristics. The most widely used capillary electrophoretic techniques include capillary zone

electrophoresis, capillary gel electrophoresis, capillary isoelectric focusing, capillary isotachophoresis and

micellar electrokinetic capillary chromatography.

2.1 Capillary Zone Electrophoresis

The Capillary zone (also referred as free-solution or open tube) electrophoresis (CZE) is the most

extensively used among the capillary electrophoretic separational techniques. In CZE separation occurs

Page 608: Instrumental

591

because analytes migrate in discrete zones and at migrational velocities based on differences in the charge-to-

mass ratio. It is essential to have carder electrolyte homogeneity and constant field strength throughout the

length of the capillary. Following sample (either electrokinetic or hydrodynamic) injection and application of

voltage across the capillary, the analytes in the sample separate into discrete zones (fig. 6). Both, macro and

micro analytes with ionic and nonionic characteristics can be separated. Cations had the shortest migration

time and are eluted first, followed by nonions and anions. Nonionic analytes are not electrophoresed but are

coeluted with the EOF. For zwitter ionic analytes (e.g., amino acids, peptides), the net charge is influenced by

the pH of the carrier electrolyte. They exhibit charge reversal at their pl as well as change in the direction of

the electrophoretic mobility.

2.1.1 Selectivity and the use of Additives

Various additives have been added to the carrier electrolyte to change the selectivity of separation. The

additives modulate the electrophoretic mobility. The carrier electrolyte (ionic strength and concentration)

composition, is varied to affect selectivity. Electrolytic additives include surfactants and chiral selectors.

Organic modifiers (e.g., methanol, acetonitrile, trifluroacetic acid) are excellent solvents for hydrophobic

proteins as they modify the electroosmotic mobility. Inorganic salts (e.g., CsCI, LiCi) are responsible for

conformationai changes in proteins.

2.1.2.1 Selection of Carrier Electrolyte

Many carrier electrolytes have been used in CZE. The electrophoretic mobility is affected by pH

changes. Therefore, carrier electrolytes must have good buffering capacity (@ 50-100 mM), low mobility (i.e.,

low charge-to-mass ratio) to reduce Joule heating and unabsorb at the detection wavelength. Effective carrier

electrolytes have a range of approximately two pH units centered on the pK= value. Certain carder electrolytes

(e.g., citrate, phosphate, succinate) have more than one useful pK= and can be used in more than one pH

range (Table 1). Zwitter ionic carrier electrolytes (e.g., bicine, tricine, CAPS, MES) are used routinely for

separating proteins and peptides. The major merit of deploying zwitter ionic carder electrolyte is their low

conductivity (ca. pH =pl), thus reduces Joule heating. The presence of salts in carrier electrolyte increase the

conductivity and reduce the electroosmotic mobility through annihilation of the charged double layer.

2.1.2.2 Hydrogen Ion Concentration

Page 609: Instrumental

592

Fig. 6. Separation of analytes into discrete zones after application of voltage across the capillary.

Page 610: Instrumental

593

Alterations in pH are particularly useful for zwitter ionic analytes (e.g., peptides and proteins). Carder

electrolyte pH above and below the pl value will change the net charge of the zwitter ionic analyte and cause

the analyte to migrate either before or after the EOF. Below its pl the analyte is cationic and migrates toward

the cathode, ahead of the EOF. Above the pl the opposite phenomenon occurs. Due to the high chemical

stability ofthe fused silica capillary, the accessible pH range is 2-12, but it is usually limited by the pH stability

of the analyte (e.g., denaturation of milk and plant proteins at its pl).

In addition to effecting the analyte charge, changing the pH will also cause a concomitant change in

EOF. This may require reoptimization of resolving conditions. For instance, adequate resolution may be

obtained at a low pH, but when increased to alter analyte charge, the EOF may be too high so that analyte

elutes before resolution is achieved. Under such conditions either increase the effective length (L,) of the

capillary or reduce the electrophoretic mobility.

2.2. Capillary Gel Electrophoresis

Capillary gel electrophoresis (CGE) (or molecular sieve) is a hybrid of traditional slab-gel and free-

solution capillary electrophoretic techniques. It is used to separate charged macroanalytes (e.g., proteins,

nucleic acids) based on molecular size, through a suitable hydrophilic polymer that acts as a molecular sieve.

In CGE separation is mainly due to electrophoretic mobility and without any contribution from electroosmotic

mobility.

The capillary dimensions and gel concentration affect separation efficiency and migration time. Small

(ca. 25 pm), medium (ca. 50-100 IJm) and large (ca. 200 pm)internal diameter capillaries have been used.

The medium size capillary inner diameter balances between minimizing thermal gradients across the capillary

and maximizing the detection path length. CGE has been performed in short (@ 0.07 m), medium (ca. 0.15-0.4

m) and long (ca. 1.0 m) effective length capillaries. Separation efficiency is improved by increasing capillary

length, although migration time increases and higher field strength is required to achieve a given separation.

As the gel concentration increases, the separation efficiency is improved.

Ionic macro- and micro- analytes will migrate through the gel filled capillary when an electric field is

applied. Macroanalytes are subjected to more impediments or frictional drag during their migration through

the polymeric network, resulting in slower migration velocity than faster migrational velocity of microanalytes

Page 611: Instrumental

594

that migrate relatively unhindered. Covalently linked polymers (e.g., acrylamide/ N,N'-methylene-bis-

acrylamide filled capillaries) are usually employed. Hydrogen-bond linked polymers (e.g., agarose) are

unstable to Joule heating produced at high voltages used in CGE.

Macromolecules (e.g., DNA, oligonucleotide, SDS-denaturated protein, peptide) are separated by capillary gel

electrophoresis, since their charge-to-mass ratio is unaffected by molecular size. In case of DNA, each

additional nucleotide adds an equivalent unit of mass and charge and does influence the mobility in free

solution. Proteins adsorb a fixed quantity of SDS (ca. 1.4 g/g of protein). SDS is an anionic surfactant and

therefore all proteins become negatively charged and migrate toward the anode.

A major merit of the CGE is efficient dissipation of Joule heating. This allows use of high electrical field

strength without the detrimental consequences of Joules heating as resolution is unaffected. Maintaining

separation range is particularly a severe problem as all the molecules must migrate the same effective/total

length of the capillary to reach the detector.

The gel is a cross-linked network, swollen with a fluid component or sol. The cross-links must be

uniformly dispersed as well as similar size, and fluid content generally dictates the size and size distribution of

the pores in the gel. The porosity of the gel influences the size separation of the analytes. Generally, the gel

concentration is inversely proportional to the size of the analyte being separated. During CGE the analytes

separate into bands with the smallest analyte migrating fastest (fig. 7).

Two classes of gels employed are physical and chemical gels. The porosity of the physical gel is due

to the entanglement of polymers and hydrogen-bonding (e.g., starch, agarose). They are quite rugged to

environmental changes. The porosity of chemical gel is due to cross-links produced by covalent, ionic, and van

der Waals interactions (e.g., acrylamide/N,N'-methylene-bis-acrylamide). These gels are less rugged, and

it is difficult to change the carrier electrolyte once the gels are formed.

Cross-linked polyacrylamide, a widely used matrix, is usually polymerized in situ and not removed from

the capillary. PreparalJon of these gels requires extreme care. Rapid polymerization, use of solutions without

degassing, or impure chemicals often lead to bubble formation or unstable gels. A potential disadvantage of

gel filled polyacnllamide is its rigid nature. This results in gel extrusion during hydrodynamic sample injections.

Therefore, gel filled capillaries are loaded electrokinetically. Several separations can be done in gel filled

Page 612: Instrumental

595

Fig. 7. Differences in electrophoretic separation based on size of the analyte.

Page 613: Instrumental

596

capillaries if they are handled properly. Soiled samples, clogged capillary ends, or bubble formation during use

reduces the performance of gel filled capillaries. Linear polymers are an option to the crosslinked

polymers. They are essentially polymer soluUons and have increased flexibility. The linear polymer solutions

are polymerized in situ, but it is not necessary. Pre-polymerized polymer can be dissolved in carrier electrolyte

and hydrodynamically loaded into the capillary.

Selectivity can be modulated by the addition of chiral selectors, ion-paring reagents (e.g., TFA), or other

complexing agents (e.g., ethidium bromide for DNA, SDS for denatured proteins). These species can be

covalently bonded to the gel or added into the carder electrolyte.

2.3 Capillary Isoelectric Focusing

Capillary isoelectric focusing (CLEF) separates polyamphyolytes or zwitter ionic analytes based on their

pl in a stable pH gradienL An ampholyte is a zwitter ionic molecule that contains both positively and negatively

charged groups such as amino and carboxylic (e.g., peptJdes, proteins). At the pl, the net charge on the

ampholyte is zero and migration ceases under the influence of an electric field. This process is termed

isoelectdc focusing. ClEF is run in a pH gradient where the anodic and cathodic reservoirs are at low and high

pH, respectively (fig. 8). The carder electrolytes generate the pH gradient. A stable pH gradient (ca. 3-9 pH)

is developed within the capillary using a wide variety of amphyolytes. A pH gradient is established by filling the

capillary with a mixture of amphyolytes dissolved in the carder electrolyte. Before the application of an electrical

field, the pH throughout the capillary is constant and is an average from all the amphyolytes in the carder

electrolyte solution. A high electrical field strength is applied (ca. 5-50 V/m). When the electric field is applied

across the capillary, the amphyolytes migrate, their buffeting capacity enables establishment of a pH gradient.

The resulting cathodic and anodic electrolyte reservoirs are alkaline and acidic, respectively. For isoelectric

focusing, the cathodic reservoir is filled with alkali (e.g., NaOH) and the anodic reservoir is filled with an acid

(e.g., H3PO4). The pH of the anodic electrolyte reservoir must be less than the pl of the most anionic ampholyte

to prevent migration into the analyte. Similarly, the cathodic electrolyte must have a higher pH than the pl of

the most cationic ampholyte.

Polyamphyolytic sample (e.g., peptides, proteins) is loaded along with amphyloytes for separation.

They migrate to the positions corresponding to their pl. When the peptides and proteins in the capillary are

Page 614: Instrumental

597

focused (i.e. steady-state) the current ceases to flow. The peptides and proteins are separated in very sharp

zones. As the focusing progresses, the current drops (ca. 1.0 pA). Overfocusing results in precipitation due

to protein aggregation at high localized concentrations. Any band broadening caused by thermal diffusion is

quickly reduced by the existing pH gradient. If a molecule diffuses (i.e., defocusing or band broadening) into

an adjoining pH zone it acquires a net charge and realigns (i.e., focuses or band sharpening) into its pl zones.

Preparative quanti'des of analytes can be separated using the CLEF, as the sample is loaded into the capillary

during filling with an amphoteric solution. Certain proteins (e.g., plant and milk) are precipitate at their pl, thus

limiting their separation by CLEF.

In CLEF, the internal surface of the capillary wall should be treated to eliminate EOF. The EOF flushes

the amphyolytes and the analytes from the capillary before the ClEF is complete. Hence, the EOF should be

lowered or eliminated. Reduction of EOF is achieved through dynamic or covalent coating of the capillary. The

capillary coating limits the adsorption of proteins on its internal wall. An important practical consideration in

ClEF is the elimination of EOF, which, if present, prevents stable focused zones from developing. Therefore,

coated capillaries are preferred for CLEF. Methylcellulose and polyacrylamide coated capillaries are used. A

potential problem with polyacrylamide coated capillaries is its attachment to the silica via a siloxane bond which

makes it unstable at high pH.

Nonionic surfactants (e.g., Triton • Brij-35), or organic modifiers (e.g., glycerol, ethylene glycol)

have been added to carrier electrolyte to minimize protein aggregation. Non-denaturing protein modifiers are

used. Urea denatures proteins and consequently avoided.

ElectrophoretJc mobilization can be accomplished in either anodic or cathodic reservoir. Mobilization

is achieved through addition of a salt solution (e.g., NaCI) to an electrolytic vessel. For anodic mobilization, a

salt solution is added to the anodic reservoir. For cathodic mobilization, a salt solution (eg. NaOH/NaCI) is

added to the cathodic reservoir. The addition of a salt alters the pH of the carrier electrolyte in the capillary.

Both, carrier ampholytes and analytes are mobilized in the direction of the reservoir with added salt. As

mobilization proceeds, the current increases as the ions migrate into the capillary.

2.4 Micellar Electrokinetic Capillary Chromatography

Page 615: Instrumental

598

Micellar electrokinetJc capillary chromatography (MEKC) is a dynamic mode of capillary electrophoresis.

It is a hybrid of electrophorelJc and chromatographic techniques. It is used particularly for nonionic and

ionic analytes with a wide range of hydrophobic and hydrophilic characteristics (e.g., microanalytes, pepUdes,

oligonucleotides). Surfactants are added to the carder electrolyte that can form micelles. The most important

feature is controlled electrophoretic mobility.

Surfactants are amphophilic moieties with hydrophobic and hydrophilic characteristics. They can be

ionic, zwitter ionic or nonionic. Surfactants have a long hydrophobic tail and a hydrophilic head. As the

concentration of the surfactant increases, they aggregate and form colloidal-sized assemblies called micelles.

The concentration at which a surfactant forms a micelle is termed critical micelle concentration (cmc) (table

2). Normally, micelles are spherical with the hydrophobic tails of the surfactant molecule oriented toward the

center to avoid interaction with the hydrophilic carrier electrolyte. The charged head is oriented toward the

carder electrolyte. During migration, the micelle and analyte complexes through both hydrophobic and

electrostatic interactions. The separation results from interaction between the micelle and the analyte.

The surfactants are broadly divided into two broad categories, synthetic (eg. anionic, cationic, zwitter

ionic, nonionic) and natural (eg. bile salt) (table 3). A variety of surfactants have been used in MEKC.

Many surfactants are adsorbed on the capillary wall. Adsorption of surfactants modifies the EOF and

limits potential analyte adsorption. The surfactant charge affects the magnitude and direction of EOF. The

direction of EOF is reversed by adding a cationic surfactant (e.g., CTAB, DTAB) to the carder electrolyte. The

CTAB monomers adhere to the wall through coulombic attraction. The positive charge results from

hydrophobic interaction between the free CTAB monomer with those bound to the internal wall of the capillary.

The ionic micelles migrate either with or against the EOF (depending on the charge). Anionic surfactants (e.g.,

SDS, SOS) migrate toward the anode, in the opposite direction to the EOF. Since the EOF is generally faster

than the migralJon velocity of the micelles at neutral or basic pH, the net migration is in the direction of the EOF.

The anionic, nonionic and cationic analytes can be separated using SDS. Generally, the anionic

analyte will be separated first followed by nonionic and calJonic analytes. Anions spend more time in the carder

electrolyte due to coulombic repulsion from the anionic micelle (e.g., SDS). The greater the anionic charge

Page 616: Instrumental

599

the more rapid the elution. Nonionic analytes are separated exclusively on hydrophobicity. CaUonic analytes

elute last due to strong coulombic attraction (e.g., ion pairing with the micelle). Neutral (e.g., hydrophobic,

hydrophilic) analytes are partitioned in and out of the micelle. Partitioning affects the separation and migration

time. The hydrophobic analytes (e.g., Sudan III) interact more strongly with the micelle than hydrophilic

analytes. The prolonged analyte-micelle interacUon results in increased migration Ume, since the micelle

carries the analyte against the EOF. When the analyte is dissociated from the analyte-micelle, the analyte is

carried with the electroosmotic flow.

The properties of the micelle are affected by operational parameters and electrolytic additives

incorporated in the carrier electrolyte. Operational parameter (e.g. temperature) dramatically effects the

micelle properties. A potential problem with the use of ionic surfactants, especially at high concentrations, is

an increase in current. As a result of which the capillary temperature rises considerably. Elevated or reduced

temperatures affect viscosity, EOF and migration lime. The addition of electrolytes to aqueous micelle systems

results in an increase in aggregation number and a reduction in cmc. The cmc for SDS in water and

phosphate/borate carrier electrolytes are 8 mM and 5 mM, respectively (Sepaniak and Cole, 1987). Organic

modifiers (e.g., methanol, 2-propanol, acetonitrile) have been used to affect analyte-micelle interaction. The

addition of organic modifiers to the carrier electrolyte reduces hydrophobic interaction between the

analyte-micelle complex. The organic modifiers affect the aggregation and the micellar ionization numbers.

Methanol enhances micelle formation at low concentrations but inhibits it at high concentrations. Acetonitrile

can hydrogen bond with water and at moderate concentration increases the cmc (Hinze, 1987).

2.4.1 Chiral Selectors

Inclusion complexes are molecular compounds with characteristic structural arrangement, in which

a compound (e.g., chiral selector) spatially encloses another (e.g., analyte) or at least part of it. The inclusion

phenomena are widely used in separationai sciences. Chiral recognition is dependent on the formation of

diastereoisomers either through covalent or electrostatic interactions. The most commonly used chiral

selectors for the formation of inclusion complexes in capillary electrophoresis are bile salts and cyclodextrins

that form steroselective interaction with the analyte. Chiral resolution by capillary electrophoresis comprises

Page 617: Instrumental

600

the addilion of a chiral selector (e.g., bile salts, cyclodextrins) into the carrier electrolyte. The migrational time

of the analyte-micelle chiral complex is increased because it moves slowly in the carrier electrolyte.

The optically active chiral additives (e.g., bile salts, cyclodextrins) permit chiral separaUon by

steroselective interaction with the analyte. In case of bile salts (e.g., sodium taurocholate, sodium glycocholate)

the chiral interaction occurs at the surface of the micelles. Cyclodextrines are another class of widely used

chiral selector. They are nonionic cyclic oligosacchaddes. They are characterized as a, 13 and T cyclodextrins

that contain six, seven and eight units of a-D-glucopyranoside, respectively. The stable L-complexes exhibit

increased migration time. Cyclodextrins are a hollow truncated cone with a cavity diameter determined by the

number of glucose units. The cyclodextrine cavity is relatively hydrophobic while the external surface is

hydrophilic. The circumference contains chiral secondary hydroxyl groups. Chiral resolution results from

inclusion of a hydrophobic portion of the analyte in the cavity and hydrogen bonding to the chiral hydroxyl

groups of the cyclodextrins. Modified ionic cyclodextrins (e.g., carboxyl, succinyl), have been used to alter

selectivity and improve detection properties. Selectivity can be modulated by using appropriate chirai selector

(chemical properties and quantity). Additionally, organic modifiers such as alcohols, surfactants, urea, and

metal ions also alter chiral selectivity as well as improve detection.

2.5 Capillary Isotachophoresis

Capillary isotachophoresis (CITP) is a moving boundary electrophoretic technique and uses a

discontinuous carder electrolytic system. The analytes condense between the leading and the terminating

electrolytes, producing a steady-state migration pattern composed of consecutive analyte zones. Either anionic

or cationic analytes are resolved during separation.

Generally, in capillary electrophoresis the analyte concentration is determined from the peak area in

the electropherogram. However, in CITP the isotachopherogram contains a series of steps, each step

representing an analyte zone. The analyte concentration is evaluated from the zone length.

CITP relies on zero electoosmotic flow, and the electrophoretic system is heterogeneous. Generally,

the separations require modified capillaries with suppressed (e.g., hydrooxypropylmethylcellulose [ca. 0.25%])

or annihilated EOF. Recently, CITP with EOF has been demonstrated (ref). The capillary is filled with a leading

electrolyte. The analytes are loaded in the capillary (ca. 30-50%) without sacrificing separation quality. The

Page 618: Instrumental

601

analytes are loaded (either electrokinetically or hydrodynamically) and the anodic reservoir is filled with

terminating electrolyte. For anionic analytes, the leading and the terminating electrolytes must contain anions

with an effective higher and lower mobility, respectively, than the anionic analytes being resolved. Under the

influence of an electric field the anions migrate toward the anode. Separation occurs between the leading and

terminaUng electrolytes based on analyte mobility (fig. 9). Since the leading anion has the highest mobility it

moves the fastest, followed by the higher and high mobility anions. Stable zone boundaries develop among

the anionic analytes, resulting in highly efficient separations. At the start of the separation, the current may be

quite high since the highest mobile leading electrolyte completely fills the capillary. As the separation

progresses, the current declines because the least mobile terminating electrolyte enters the capillary.

CIPT has two characteristics, the combination of which is unique to electrophoretic methods. The

anionic analytes migrate in discrete zones or bands. Additionally, all analyte zones move at the same velocity.

The migration velocity is influenced by the characteristics of the leading anion. The higher mobile zone has

higher conductivity (lower resistance) and a lower voltage drop across the zone. The mobility is the product

of the voltage drop and the conductivity. The voltage drop is an inverse function of conductivity. Thus, the

electrical field strength varies in each zone and normalizes to maintain constant velocity (velocity = mobility X

field), with the lowest field across the zone having the highest mobility. If an anion diffuses into adjoining zones

(i.e., defocusing or broadening), it is accelerated or decelerated based on the electrical field strength

encountered and realigns 0.e., focuses) into the corresponding zone. This phenomenon results in very sharp

analyte zones.

A demerit of CITP is the adjoining analyte zones are in contact with each other. Spacer molecules

have to be employed to overcome this drawback. A spacer is a nonabsorbing molecule with a mobility value

between the mobilities of two analytes being separated.

Various compounds have been added to the carder electrolyte in order to form complexes. These

complexes permit the effective mobilities of the analyte anions to be controlled and thus optimize separation.

The 13-cyciodextrins have been added to the leading electrolyte. Also, small amounts of

hydrooxypropylmethylcellulose are added to the leading electrolyte. It dynamically coats the internal wall of

the capillary, reduces adsorption of proteins and annihilated the electrical double layer.

Page 619: Instrumental

602

Selection of an appropriate leading and terminating electrolytic systems within the pH that contain both

leading and trailing anions/cations is a difficult task. The leading cathodic electrolyte might contain a strong acid

(more mobile e.g., H3PO4 [ca. 5 mM]), while the terminating anodic electrolyte might contain a weak acid (less

mobile e.g., propionic acid or valine). For cationic system, consisting of acetate as the leading electrolyte (ca.

10 mM pH 4.75) and acetic acid as the terminating electrolyte (ca. 10 raM). On the other hand, for the anionic

system, formic acid titrated with ammediol (ca. 10 raM, pH 9.1) is deployed as the leading electrolyte and

alanine-ammediol (ca. 10 mM, pH 9.5) is deployed as the terminating electrolyte.

3. INSTRUMENTATION

InstrumentalJon development for capillary electrophoresis has progressed tremendously. The typical

capillary electrophoretJc system consists of: 1) Sample applicator; 2) Separating capillary; 3) Detector; 4) Liquid

handling system and 5) Electrical energy source.

3.1 Sample Application

The small capillary dimension limits the quantity of the sample that can be loaded. Generally, the

injection plug length should not exceed 1-2% of the I..t of the capillary. This corresponds to a sample injection

volume of 1 to 50 nL, depending on capillary dimensions. Generally, samples are loaded appropriately.

Severely underloading the sample may avoid analyte detection. An advantage of underloading is high

efficiency. On the other hand, sample overloading is generally routine and is detrimental to resolution. Injection

plug lengths longer than the diffusion controlled zone width will proportionally broaden peak width. Additionally,

it intensifies field inhomogeneities and distorted peak shapes due to mismatched conductivity between the

carrier electrolyte and the analyte zone.

Two methods commonly used in loading samples are electrokinetic and hydrodynamic injections. In

both methods the injection volume is indirectly calculated from defined operational parameters. The defined

operational parameters are voltage/'dme for electrokinelJc injection, or pressure/time for hydrodynamic injection.

3.1.1 Electrokinetic Injection

Page 620: Instrumental

603

An electrokinetJc (i.e., electromigration) injection is performed by exchanging the injection-end reservoir

with the sample vial and replacing the sample vial with the reservoir buffer. Following this step the voltage is

applied across the capillary. Normally, the sample loading voltage is 3-5 magnitudes lower than sample

separation voltage. The sample enters the capillary by both electrophoretic and electroosmotic effects. Since

the sample loading is influenced by electrophoretic mobility, the high mobile ionic species are loaded at a

greater concentration than the low mobile counterparts. Despite the quan~ative and reproducible drawbacks,

electrokinetic injections are easy to perform, do not demand supplementary device, and suitable for viscous

media or gels utilized in the capillary electrophoresis.

3.1.2 Hydrodynamic Injection

A hydrodynamic injection is the most broadly used sample loading method. It is achieved by: 1)

applying pressure at the capillary injector-end 2) vacuum suction at the capillary detector-side, and 3) siphoning

action or hydrodynamic imbalance by lifting the injector-end reservoirs compared with the detector-side

reservoir. W'rth hydrodynamic injection, the quantity of the sample loaded is nearly independent of the sample

matrix.

The sample volume (V,) for a pressure/vacuum injection can be calculated by the Hagen-Poiseuille

eq. (21). The volume (V,) is dependent on capillary dimensions, the carder electrolyte viscosity, the applied

pressure/vacuum differential (AP), and the time (tO. Typically injection pressures and times range from 103-104

Pa (10-100 mbar) and 1-5 s, respectively.

V, = nz~Pd,~,/128nL, (21)

A siphoning injection is performed by elevating the injector-end reservoir (0.1-0.3 m) compared with

the detector-end reservoir for 10-25 s. Siphoning injection is used in systems without pressure injection

capabilities.

Whenever possible apply the shortest sample injection plug length. However, short injection plug

length reduces sensitivity and reproducibility. The effect is pronounced in small and/or broad-bore capillaries

or when concentrated samples are applied. The temperature is another, operational parameter that requires

Page 621: Instrumental

604

control during sample injection. The V, varies 2-3%/~C. Therefore, precisely regulating and maintaining the

capillary temperature (2. 0.1~ limits variations in V,.

3.1.2 On-Capillary Sample Concentration

Concentrating sample on-capillary during or following injection increases selectivity. Sample

concentrating methods based on the field strength differences between the sample zone and the carder

electrolyte, are called stacking, in an alternate stacking method, the sample conductivity is significantly lower

than that of the carder electrolyte. Stacking is achieved when the sample is dissolved in water or low

conductivity electrolyte and injected hydrodynamically or electrokinetically.

An important consideration during stacking is Joule heating in the sample zone due to a voltage drop

in the stacking zone. Temperature exceeding 90~ in the sample zone, even with capillary regulation, have

been reported. This can particularly affect thermolabile samples.

3.2 Separating Instruments

The capillaw electrophoretic separating instruments include; the capillary, and capillary temperature

regulator.

3.2.1 Capillary

Both fused silica and Teflon are chemically as well as electrically inert and used for constructing

capillaries. Other desirable features in capillaries are flexibility, ruggedness and transparency to t.W-visible light.

Fused silica capillary meets most of these requirements and is commonly used. Since, silica is very brittle and

fragments easily a polyimide coating renders the fused silica capillary rigidity. The polyimide coated fused

silica capillary can be wound into narrow loops. However, the opaqueness prevents on-capillary detection. A

short segment of the protective polyimide coating is removed to enable optical detection. This can be done by

either thermal, mechanical or chemical method. Fused silica adsorbs analyte and exhibits poor heat transfer

properties. Capillaries have been constructed of Teflon. They are transparent to UV light and non-ionic but

exhibit significant EOF. However, they are used sporadically. Other problem encountered are in constructing

uniform internal diameter capillary. Like fused silica, Teflon also adsorbs analyte and exhibits poor heat

transfer properties.

Page 622: Instrumental

605

Polyimide coated fused silica capillaries of various dimensions are available. A wide range of internal

(10-200 qm) and external (200-500 rim) diameters are manufactured. However, 25-75 qm d~ and 350-400 rim

do are commonly used. The I_, of the capillary varies with analysis time and separation mode. Both short (0.1

m e.g., CGE) and long (0.8-1.0 m e.g., for complex-sample CZE) effective length capillaries are used.

Generally, capillaries of 0.5 to 0.75 m are used. Ideally L, should be about 85% of the Lt. The I-t exceeds the

1.1 by about 0.05-0.15 m.

A short segment of an extremely narrow bore capillary (e.g., 10-20 IJm d~ has been coupled to two long

segments of a wide bore capillary (e.g., 50-75 pm d~. This configuration combines the easy handling of long

capillaries and improves the sensitivity of detection due to broader capillary diameters with the enhancement

of separating efficiency provided by capillaries of narrow diameters (Monnig and Jorgenson, 1991 in Anal Chem

V. 63,p. 802).

Besides cylindrical capillaries other geometric cross-sections have been used. These include

rectangular and square cross-sections. The separation efficiencies were comparable for circular, rectangular

and square capillaries ('rsuda et al. Anal. Chem 1990, V. 62, p. 2149).

3.2.2 Capillary Conditioning

During the electrophoretic separation of proteins, the property of the capillary internal wall is altered.

The altered surface has to be regenerated for further analysis. If the surface characteristics are not

regenerated to the original condition then the reproducibility is affected. Hence, it is necessary to maintain a

reproducible capillary surface. This process is called as capillary conditioning. The most reproducible

conditions are achieved when the capillary is flushed with a carrier electrolyte. This process is achieved when

the sample is not adsorbed on the surface and the EOF is unaltered.

Alkaline conditioning to desorb the adsorbates (eg. proteins) and refreshen the surface by

deprotonation of the silanol groups is most commonly employed. Precondition new columns following

manufactures recommended procedures. Commonly used washing agents are dilute alkali/acid, a mixture of

organic solvents with incorporation of detergents. Finally, condition the capillary with the carrier electrolyte to

equalize the column.

Page 623: Instrumental

606

Alkaline conditioning is a concern, chiefly when low pH carrier electrolytes are deployed due to

hysterisis of the surfacial charge. The hysterisis affect the EOF reproducibility and demand prolonged

conditioning Umes. Thus equilibration with alkaline buffers may need to be avoided under such conditions.

The adsorption of electrolytic additives affects the capillary surfacial charge. Constant surfacial charge

enables reproducibility. The surfacial adsorption of phosphates is reversible but prolongs conditioning times.

Surfactant adsorption is often irreversible. Therefore, capillaries used for certain chemicals are exclusively

committed for that purpose.

3.2.3 Capillary Temperature Regulator

The electrical current required to drive the electromigration of analytes in capillaries increases

considerably with an change in carder electrolyte temperature. Temperature shifts affect not only the precision

of peak areas and migration times, but they can also degrade thermolabile analytes. There are at least two

different ways of eliminating the effect of temperature on migration time. The first approach consists of an

application of normalization procedures. The second approach involves capillary temperature regulation.

Regulation of capillary temperature is important for replicating results. Temperature regulation to + 0.1~ is

benefidal due to the temperature affect on viscosity. The three types of temperature control systems are used

in capillary electrophoretic instruments include: a) suspension of capillary in forced air circulation b) suspension

of capillary in thermally insulated chamber and c) liquid immersion are used. Although liquid immersion to

control capillary temperature is efficient forced hot air circulation is the method of choice. Liquid immersion is

efficacious at higher field strength. The merits of forced air circulation are engineering and economics.

3.3 Detection

The sample is loaded in nanoliter quantities because of the small size of the capillary. Additionally,

the extremely short path length encountered in on-capillary detection present a challenge to achieve sensitive

detection without introducing zone dispersion. Thus, detection is a tremendous task in capillary electrophoresis.

A variety of detection methods are used in CE. Of-these the on-capillary ultraviolet-Visible absorption and

fluorescence detectors are more common.

3.3.1 Ultraviolet-Visible Detectors

Page 624: Instrumental

607

The ultraviolet-visible absorption detector is the simplest and most universal detection technique (R.

Wallingford and A. G. Ewing, Anal. Chem., 59(1987) 678-?; J. S. Green and J. W. Jorgenson, J. Liq.

Chromatogr. 12(1989) 2527-2561). The fused silica capillary can detect in both the ultraviolet (170-320 nm)

and visible (320-660 nm) spectra. The high efficiency observed in CE is due in part to on-capillary detection.

In on-capillary detection the path length is defined by the inner diameter of capillary. This limits the sensigv----------------~

of absorbance, since sensitivity is proportional to the path length. Additionally, in the capillary (i.e., the detection

window) the zone does not broaden due to dead volume or component mixing. An important consideration with

optical detectors, particularly for CE is the slit dimension of the detector. The slit width must be suitably small

to the analyte zone width to maintain high resolution. Detectors with 100 pm pin-hole slits have been employed

to cutoff stray light and ensure good resolution.

The probability of absorption at a single wavelength is characterized by the molar extinction coefficient

at that wavelength. If light of intensity Io passes through the capillary path length I, filled with analyte of molar

concentration 'c' molar, the intensity I of transmitted light is given by Beer-Lamberts law as:

I/1o = elfc (22)

Since path length influences the sensitivity. The short path length limits s e n s ~ in CE.

3.3.2 Fluorescence Detectors

Among the aitemative techniques, fluorescence is used in commercial electrophoretic systems J. W.

Jorgenson and K. D. Lukacs, Anal. Chem., 53(1981) 1298-1302; B. L. Krager, A. S. Cohen and A. Guttman,

J. Chromotogr. Biomed. Appl., 492(1989) 585-614.; K. A. Cobb and M. Novotny, Anal. Chem., 61(1989) 2226-

?; B. Karger, Nature, 339(1989) 641-?)). A requirement for fluorescense is that the analyte must contain a

fluorophore. The principal benefit with fluorescence detection is the significant increase in sensitivity and can

be detected in the pM (10 "12 M) range (S. Wu and N. J. Dovichi, J. Chromatogr., 480 (1989) 141-155). For

analytes that are not fluorescent, pre- or post-column derivatizalJon may be employed to introduce fluorophores

into the analyte molecule (A. G. Ewing, R. A. Wallingford and T. T. Olefirowicz, Anal. Chem., 61 (1989) 292A-

303A.).

Page 625: Instrumental

608

Fluorescense occurs through photon absorption by the analyte and emission of light of a longer

wavelength. As is true for absorption spectroscopy, there are many environmental factors that affect the

fluorescense spectrum. Furthermore, fluorescense efficiency is also environmentally dependent. Because

these parameters are more sensitive to the environment than those of absorbance and because smaller

amounts are required, fluorescense detection is frequently of greater value that absorbance detection.

Other detection systems that have been attempted include: laser-induced fluorescense, mass

spectrometric, conductivity and amperometric detection. Novel detection techniques, such as

chemiluminescence, semiconductor laser fluorimetn] and electrochemical methodologies have been reported.

3.4 Liquid Handling

The separating efficiency in capillary electrophoresis is further improved by automated liquid delivering

systems. Of the various liquid delivering systems the autosampler and the electrolyte replenishment and

leveling are most useful instruments.

3.4.1 Autosampler

The autosampler is beneficial for routine sample analysis. The sample vials are loaded and the

sampling process is ini'dated. The autosampler sequentially transports the sampling vials and electrolytic vials

to the injector-side capillary end for analysis.

3.4.2 Electrolyte Replenishment and Leveling

During electrophoretic separations current passes from the cathode to the anode. The electrolytic

reactions produce hydrogen at the cathode and oxygen at the anode. The electrolytic depletion is dependent

on the current generated and separation time. Additionally, during electrolysis the buffering capacity as well

as pH are altered and the EOF is affected. Therefore, the reservoir electrolyte has to be replenishment and

restored to its original concentration. The extent of replenishment and restoration is dependent on the buffering

capacity, reservoir volume and if the capillary conditioning washes exit into the detector side reservoir. The

electrolyte level in both reservoirs must be at the same liquid level. This limits siphoning of the electrolyte from

one reservoir to the other. If the electrolytic levels in the reservoirs are altered, then it affects efficiency and

migration time.

Page 626: Instrumental

609

Generally, most systems are designed for electrolyte replenishment but not electrolyte restoration. The

instrument functions by emptying the contents of both the reservoirs and refilling them with fresh electrolyte.

An electrolyte leveling system would accurately replenish electrolyte according to user specifications. A large

reservoir provides the capability to run automated analysis of several samples for a prolonged period of time.

2 e + 2H20 ~ > 2 OH + H2 (Cathodic Reaction)

2 H20 ~ > O2 + 4 H § + 2 e- (Anodic Reaction)

(23)

(24)

3.5 Electrical Energy Source

The electrical energy necessary for capillary electrophoretic separations is provided by a regulated

direct current power supply which is connected by a pair of insulated cables to the two electrodes. The

electrodes are usually made of platinum or other chemically inert metal, immersed in the carrier electrolyte.

The voltage may be as high as 50 kV and current levels of 500-1000 pA. A good power supply must provide

a stable regulation ofthe voltage (! 0.1%) and have provisions to reverse polarity. It is also beneficial if polarity

switching is software controlled, especially if switching is desired during an analysis. Most power supplies are

set up to operate in the constant voltage mode. However, a constant current or power mode is useful.

Constant current or power mode is particularly useful for isotachophoretic separations or when capillary

temperature is inadequately controlled. Temperature changes alter electrolytic viscosity and migration time

in constant voltage mode. In constant current mode, these viscosity changes are compensated by proportional

changes in the applied voltage, maintaining constant migration temperature. Additionally, power supply with

capability to run voltage, current or power gradients during an analysis is preferred. Field programming can

be used to ramp the voltage at the beginning of an analysis to avoid rapid heating, thermal expansion of the

electrolyte, and eluting the sample from the capillary. Field programming is particularly useful for decreasing

the analysis time of complex samples and is often necessary for fraction collection.

4.0 APPLICATIONS

Page 627: Instrumental

610

Although capillary electrophoresis is a relatively new analytical technique in food analysis, much

information has been published in recent years.

4.1 AMINO ACIDS

Separation of amino acids has been one of the more food components reported in the literature using

pre-and post- capillary dedvatization. The majority of the separations have been achieved by dansylated

derivatives, phenylthiohydantoin derivatives, naphthalene dicarboxaldehyde derivatives, 4,4-dimethylamino

azobenzene-4'-sulfonyl chloride derivatives, fluorescein isothiocyanate derivatives, ortho-phthaldiadehyde

derivatives, fluorescamine derivatives, and 9-fluorenylmethylchloroformate derivatives. Successful separalJons

have been made without the use of a derivative. Detection has been achieved using gradient, indirect

fluorescence, and amperometric techniques. The sensitivity of some of these methods are sufficient for

hydrolysate analysis and sequencing.

4.2 PEPTIDES

Proteins have been fragmentized to produce peptides which have been analyzed by capillary

electrophoresis. Enzymatic cleavages have been used to analyze egg-white lysozyme and chicken ovalbumin.

The separations were reported to be equal to traditional electrophoresis methods. Fourteen peaks from g-

casein were separated with relative standard deviation values less than 1% for all peaks. Protein fragments

separated have ranged from 1 amino acid to 35 amino acid peptides. Capillary electrophoresis-mass

spectrometn/(CE-MS) with electrospray ionization at atmospheric pressure has been used to analyze peplJdes.

Both CE-MS and CE-MS-MS have also been successfully utilized.

4.3 PROTEINS

A variety of proteins have been successfully separated by capillary electrophoresis including: whale

skeletal myoglobin; carbonic anhydrase A and B; g-lactoglobulin A and B; lysozyme; and chicken egg

ovalbumin. As with peptides, capillary zone electrophoresis-mass spectrometry (CZE-MS) with electrospray

ionization (ESI) has been used for protein analysis.

Page 628: Instrumental

611

4.4 NUCLEIC ACIDS

Total hydrolysis of nucleic acids produces phosphoric acid, ribose or deoxyribose, and purine and

pyrimidine bases. A partial hydrolysis will produce nucleosides, nucleoUdes, and oligonucleotides. Since

nucleic acids have varied chemical configurations as, native and single-stranded DNA, circular and supercoiled

DNA, viral and phage RNAs, rRNA, mRNA, tRNA, DNA-RNA hybrids, natural and synthetic mono- and

polythematic polymers, the procedures for their separation and generally complex procedures. Most of the

studies to-date have focused on the development of CE methods for isolation, purification, and sequencing.

4.5 CARBOHYDRATES

Capillary electrophoresis has progressed where it is considered as a viable alternative to traditional

analytical techniques as thin-layer, gas, and high-performance liquid chromatographies. The photometric

detection of underivatized carbohydrates has been difficult to achieve. Recent methods which increase

detection sensitivity have been reported using borate complexation or with derivatives using fluorogenic

reagents.

4.6 VITAMINS

Both water and fat soluble vitamins have been separated by CZE. Only limited information has been

reported on vitamin separaUon.

4.7 ORGANIC ACIDS

The use of CZE for low molecular weigh carboxylic acids has been reported in the literature. The

organic acids in a variety of food products as apple juice, tomato juice, soy sauce, and wines have been

published. Capillary zone electrophoresis has been shown to be a low-cost, quantitative, and selective method

of analysis for these compounds.

4.8 AMINES

Page 629: Instrumental

612

Biogenic amines as well as n-hexyl, n-butyl, and n-propylamines and n-octyl, heptyl, hexyl, pentyl, butyl,

and propyl amines has been reported.

5.0 FOODS

A variety of food products have been analyzed by CZE. These include: the separation of water-soluble

vitamins in caffeine; separation and identification of amine-containing compounds in red wine; biogenic amines

in fish; bitter acids in hops; proteins in milk; organic acids in fermented cabbage; and food colors.

5.0 REFERENCES

P. D. Grossman, in: P. D. Grossman and J. C. Colburn (Eds.), Capillary Eiectrophoresis Theory and

Practice. Academic Press Inc., 1992.

S. F. Y. U, Capillary Electrophoresis Principles, practice and applicaUons, Elsevier Science Publishers B.V.,

Amsterdam, The Netherlands, 1992.

P. Jandik and G. Bonn, Capillary Electrophoresis of Small Molecules and Ions, VCH Publishers Inc., 1993.

Page 630: Instrumental

613

INDEX

absorbance- 226, 2 2 7 , 2 2 8 , 2 3 1 , 2 3 2 , 234, 236, 2 3 7 , 2 3 8 , 2 3 9 , 240 Acacia gums - 116 Acacia Senegal- 114, 116, 117, 118, 120 Access- 489 ,490 , 495 ,496 acetaldehyde- 306, 307 acetals- 303 acetates- 262 acetic acid - 89, 309, 315 acetic anhydride - 89 acetoin- 309 acetolysis - 108 acetonitrile - 416, 418, 419, 420, 421 ,422 , 423 acetyl guanidine - 89 acetyl phosphate - 89 acetyl-coenzyme A - 352 2-acetylfuran- 278, 279, A70 acetylpyrole- 230, 2 3 1 , 2 3 3 , 2 3 5 , 2 4 0 , 278, 281 2-acetylpyrole- 278,281 A-chains - 62 acid catalyzed esterification- 197 acid degradation - 53 acid hydrolysis - 49, 111 acid modification- 54, 55, 67, 71, 74, 75, 79, 80, 81, 84, 85, 87, 88 acid thinning - 87, 88 acknowledgements - 511 acousto-optic crystal - 185 acousto-optic tunable filter spectrometer (TFS) - 182, 184, 185, 186, 187, 188, 189 acrylamide - 474, 475 activated carbon- 225 adsorbent trapping - 225 adulteration- 364 agar - 128, 134 alcohol(s) - 108, 1 4 8 , 2 2 8 , 2 3 0 aldehydes- 228 ,229 alditol acetates - 109 algae - 121, 122 alginate- 25, 100, 121, 122, 125, 135, alginate (PGA) - 25 aliphatic - 145, 146, 304

aliphatic esters - 248 ,252 aliphatic hydrocarbons- 264 alkali-labile- 72 alkaline fluidity- 79 alkaline sodium hypochlorite - 89 alkali-number- 72 alkyl esters - 493 alkyl groups- 262 alkyl vanillylamides- 359 alkylation- 264 alkylpolysiloxanes - 199 allylmethyl disulfide- 291 ,293 American Spice Trade Association (ASTA)- 350. 351 ,370 amide - 147, 151 ammonia- 263 ,264 , 271 ammonium vanadate- 362 amorphous zones - 49, 74 ampholyte- 596, 597 amyl alcohols- 306, 308, 312 amylase - 53, 72 "-amylase- 85 S-amylase - 85 amylaser- 85 amyloglucosidases - 85 amylolysis - 85, 86 amylopectin- 49, 51, 62, 74, 78, 83, 110- 141 amylo-phosphoric acid - 72 amylose- 49, 51, 63, 73, 79, 83, 87, 110- 141 anaerobic and sulfide spoilage organisms - 87 trans-anethole- 544 AnGal - 130 S-angelica lactone - 533 anhydroglucose - 49, 51 anodic electrolytic vessel- 576, 577 anomalous dispersion- 156, 159, 160 anomeric configuration - 105 anthrone - 108 antibodies - 109, 123 antigen - 109 AOCS - 212 AOCS-AOAC method- 206

Page 631: Instrumental

614

Apiezon - 199 Arabic gum - 91, 100, 114, 116, 118, 119, 120, 134 ar-curcumene- 548 argenta t ion-TLC- 207 a roma- 249, 265 aromatic - 145, 146, 147, 304 Arrhenius equat ion- 36, 37, 39 arrow roo t - 86 artemisia alcohol - 528 artemisia ketone - 521 artemisia triene - 512 artifact formation - 197, 198 artifacts- 358 artificial intelligence (AI) - 490 Ascophuyllum nodosum - 121 ash - 51 aspartane- 454, 4 5 5 , 4 5 6 Association of Official Analytical Chemists (AOAC) - 211 ,212 , 307, 350 ASTA method 20.1 - 357 ASTA/AOAC me thod- 357 axial - 101 azeotropic- 312, 323 Aztecs- 359 baby food - 211 backflushed- 320 background noise- 247 banana starches - 86 Barabyai and Szabolcs - 351 barley - 74, 84 BASIC - 495 bas i l - 272 B-chains - 62 beef - 209, 211 Beer-Lambert l a w - 143, 155, 160, 190, 603 bell peppers - 363 benzene- 142, 146, 147, 148, 185, 190 benzyl benzoate- 542 benzyl esters - 262 benzaldehyde- 229, 2 3 2 , 2 3 3 , 2 3 6 , 240 benzyl acetone - 522 benzyl cinnamate (E) - 539 benzyl t ig la te- 539

berries - 253 BHT - 197 bias - 169 binary biopolymer mixtures - 23 binding agents- 91 binding capacity - 99 binodal - 26 biconvex d isks- 55 Biopolymer- 1, 2, 7, 12, 18, 21, 23, 45, 44, 99 biosynthesis- 102, 359 biphasic system - 196 birefr ingence- 55, 68, 69 Bligh - 196 blueberr ies- 205 boron trichloride - 205 borosilicate g lass - 226 Brabender amylograph - 76 Brabender Viscograms - 77 breakdown- 7 bright field- 109, 113 Brookfield- 75 Buchol tz- 359 Buckle and Rahman - 353 n-butanol - 196 "-cadinol (I) - 549 calibration membranes - 104 caloric content - 195 "-campholene aldehyde - 519 (-campholene aldehyde - 519 "-campholenic acid, methyl es te r - 536 (-campholenic acid methyl es te r - 536 canna- 86 cannabis sat iva- 256 Cannuum- 348 canonical variables - 142, 172 capillary - 75, 199, 200, 203 ,206 , 209, 211, 294, 304, 305 ,306 , 310, 313, 316, 317, 320, 3 2 5 , 3 2 7 , 3 3 5 , 3 3 6 capillary electrophoresis- 575 ,590 , 599, 600, 602, 603 ,606 , 6 0 7 , 6 0 8 , 6 1 0 , 611 capillary gel e lectrophoresis- 590, 611 ,612 capillary isoelectric focusing- 590, 596, 597 capillary isotachophoresis- 590, 600, 601

Page 632: Instrumental

Capillary SFC - 477-487 capillary zone electrophoresis - 590, 611, 612 capsaicinoid quanti tat ion- 362 capsaicinoids- 359 capsanthin- 3 4 7 , 3 5 3 , 3 5 9 capsicum oleoresin - 452 capsicums- 347-374 capsorubin- 347 ,353 carbohydate(s) - 145, 149, 150, 151 carbohydrate chemistry - 101 carbon tetrachloride - 363 carbonyl compounds- 2 2 5 , 2 7 1 , 2 9 5 , 3 0 3 Carbopack B/carbosieve S-Ill - 226, 231, 234, 2 3 7 , 2 3 8 , 2 3 9 , 2 4 0 , 308 carbotrap - 332 Carbowax- 199, 200, 202 ,206 , 207 ,249 , 253,307-310, 3 1 3 , 3 1 5 , 3 2 4 , 332 carbowax 20M - 199, 200, 2 0 2 , 2 0 6 , 2 0 7 2-carboxaldehyde-5-hydroxymethylfurfuran - 559 carboxylic acids - 303 carboxymethyl cellulose (CMS) - 107 carotenoid- 347-374 carotenoid biosynthesis - 352 carotenoid diesters - 355 carotenoid monoesters - 354 carotene stabil izer- 91 carrageenan- 100, 109, 121, 126, 127, 128, 129, 130, 131, 132, 133 carrageenophytes - 126 Carrez reagent - 111 carrier e lect rolyte- 575 ,585 , 587, 588, 589. 5 9 1 , 5 9 3 , 5 9 7 , 5 9 8 , 599, 600, 601, 604, 605 carrier gas - 249 carvacrol - 546 case registry number - 503 casein- 126 cassava- 49, 53, 62, 67, 76, 83, 84, 86 cathodic- 576 C-chains - 62 cedar - 263 Cellulose - 150, 151 ,354 central nervous system - 207 centrifugal partition chromatography - 325

615

Ceuaxi - 209 chain configuration - 105 chair conformations - 101 checking of a compound - 499 cheese - 209, 210 chelate - 105 chemical ionization- 263 chemical ionization chamber - 263 chemical ionization techniques- 263 chemical methods - 72 chemiluminescent nitrogen detectors ( C L N D ) - 377-488 chemiluminescence- 378, 381 ,382 , 383, 3 8 7 , 3 9 1 , 4 2 7 , 4 7 7 , 4 8 0 , 608 chemometric classification - 116 chemometric methods - 117, 141, 143, 161, 175, 182, 192 Chemstat ion- 336, 338 Chemwindows - 489, 503 Chernoff faces - 314 chicken - 311-313 Chi le - 347-374 Chile powder - 359 Chile pungency analysis - 358 chiral selectors- 5 9 9 , 6 0 0 ch ive- 272, 278 cholestane- 365 Chondrus crispus - 126, 127 Christie - 196, 198 ,200 Chroma- 350 chromameter - 349 chromatogram- 2 4 5 , 3 5 8 chromatographic - 178, 192 Chromosorb- 2 0 3 , 3 0 7 , 3 2 7 Chromosorb W A W - 203 chrysantenyl tiglate (Z) - 541 trans-methyl chrysanthemate- 538 C I - 294 C I E - 349 C I E L A B - 349 trans-cinnamaldehyde- 520 cis-cinnamyl t ig la te- 540 trans cinnamyl t iglate- 540 circular dichroism ( C D ) - 123, 124, 125 citronellyl es te rs - 262

Page 633: Instrumental

616

citronellyl tiglate (E.I) - 541 clear all - 506 clear last session - 506 cloud po in t - 26 cluster analysis - 117 ,228, 231 Code of Federal Regulations (CFR) - 195 C o E - 503 coelectroosmotic electrophoresis - 579 cognac- 303 ,304 cold capillary programmable injection technology- 304 cold programmable injection (CPI) - 316, 317, 327 cold t rapping- 200 cold t raps- 323 ,324 cold water swell - 90 color difference me te r - 349 color imeter- 349, 361, 370 Colorimetric procedures /methods - 106, 362 columbic forces- 588, 589, 598 ,599 column(s)- 356, 501 Combretum - 116 complex linear repeats - 101 complex periodic structures - 101 component managing- 496, 497 ,506 , 511 computational algorithms - 168 computerizat ion- 245 concentric cylinder - 16 concentric cylinder geometry - 16 cone-and-plate - 15 congeners- 303 ,302 , 303 Congo red - 51, 113 connective t issue- 99 controlled fermentat ion- 72 controlled liquid fermentat ion- 100 cooling scan- 35 co-operative junctions - 24 copper co lumn- 307 co rn - 49, 72, 74, 209 corn starch - 110, 112 correlation - 165, 167, 175, 179 correlation coefficient - 165, 166, 167 cottonseed o i l - 209 Coulter counte r - 52

counter currents - 22 counter electroosmotic electrophoresis - 579 coupled networks - 23, 24 covalent l inkages- 24 CPM - 495 Craske and Bannon- 201 creep curve - 7 creep experiment - 16 Cristopherson and Glass - 198 crossl inking- 24, 49, 80, 81, 86, 88, 89 cross polarization magic angle spinning ~3C CP MAS N M R - 105, 113, 132, 133 cross-bonding- 73 cryo -enrichment device (CTE) - 336, 337, 339 cryofocusing- 332, 334, 342 cryogenic t rapping- 225 cryotrap (CTS) - 336, 337, 339 cryptocapsin- 347 CrystaLean - 111 crystalline capsaicinoids- 364, 365 crystalline zones - 49, 74 crystal l ini ty- 55, 62, 67, 68, 90, 113 crystall ization- 99 cul t ivar- 349, 360 ( -curcumene- 548 cyanopropyl polysioxanes - 199 cyclic carotenoids - 353 cyclic ethers - 270 cycloalkanes- 264 cyclobenzene - 142 damaged starch grains - 72 $-damascenone- 524 $-damascone- 524 deaminat ion- 306 debranching enzymes - 85 trans, trans 2,4-decadienal - 518 decalatone- 249 (-decalactone - 534 decanal - 518 decanoic - 313 decanol - 3 - 319 decarboxylat ion- 306 deformat ion- 6 degree of esterification (DE) - 111, 113

Page 634: Instrumental

degree of polymerization (DP) - 106 degree of substitution (DS) - 107 degree of unsaturation - 146, 147 delta cadinol - 550 delta decalactone - 535 denatured mi lk / soya proteins - 32 density - 55, 106, 107 density gradient analysis - 106, 107 Depentenizer Feed Overhead - 422 derivatization - 197 desorbing- 226 detection electrophoresis - 104 dextrans - 104 dextr in- 72, 85, 88 dextrinization- 88 Dextrose Equivalent (DE) determination- 111 Di Corc ia - 308 diallyl disulfide - 2 9 2 , 2 9 3 , 2 9 4 , 531 diallyl tr isulfide- 531 dialysis- 360 Diazomethane - 198,203 dichloromethane - 321 dietary f iber - 100, 111, 179, 180 diethyl acetal- 306, 307 ,312 , 320 diethyl ether - 196 3,6-diethyl- 1,2,4,5-tetrathianes (two isomers)- 566 differenital scanning calorimetry (DSC) - 68 diffuse reflectance - 142, 143, 149, 150, 152, 153, 155, 157, 159, 160, 169 diffuse reflactant- 71 diffuse transmittance- 157, 160, 180 diffusion - 104 diffusion coefficient- 584, 587, 588 digital image analysis (DIA) - 109 dihydrocapsaicin- 348, 359 2,3-dihydro-3,5-methyl pyrazine- 229, 233, 236, 240 D I K - 262 dilute solutions - 18

Dimethyl amines - 481 N,N-dimethyl fo rmamide- 514 2,3-dimethyl pyrazine - 285 2,5-dimethyl pyrazine - 229, 2 3 1 , 2 3 3 , 2 3 5 ,

617

240, 283 2,6-dimethyl pyrazine- 284 3,6-dimethyl- 1,2,4,5-tetrathianes (two isomers)- 566 3, 5-dimethyl 1, 2, 4-trithiolane (two isomers)- 564 dimethyl vinyl pyrazine- 229 ,232 , 233 dimethylvinylpyrole- 238 diode array - 182, 183, 184, 189 diode-array detector- 356 dionyl sevacate- 307 direct gas chromatography - 225 direct injection- 305 ,306 , 320 direct splitless injection - 315-319 discriminant analysis - 172, 174 discriminant component analysis (DCA) -

1 1 7 , 141 disentanglement- 22 diisopropyl disulf ide- 532 dispersion- 584, 585 dissimilarity index compar ing- 247 distillation- 320-322 Distillation Chemiluminescent Nitrogen Detection (S imDis /CLND)- 4 2 7 , 4 2 8 , 4 3 0 distilled wines- 309 diterpene - 248 dynamic coating - 589 docosahexaenoic acid - 206, 207 (-dodecalactone - 534 dodecanoic - 313 donuts - 2 0 9 , 2 1 0 drag cup - 14 DRI (differential refractive index) -469-476 Duncan and Philip - 307 Dyer - 196 dynamic viscosi ty- 12 dynamic headspace- 304 ECD - 200 "-eduesmol (eduesm-3-en-11-ol) - 551 effluent spli t ter- 320 Egg McMuff in - 209 EGSP-Z - 199 EGSS-Y - 199 Egyptian - 62 eicosapentiaenoic ac id- 206, 207

Page 635: Instrumental

618

electrical fo rce - 578 electrochemical detect ion- 367 e lect rode- 262, 577 electrodispersion- 585 electrokinetic injection - 602, 603 electrometric t i t rat ion- 72 electron impact (EI) - 246, 248 ,254 , 256, 260, 263 electroosmotic f l ow- 578 ,579 , 582, 584, 586, 588, 589, 5 9 1 , 5 9 3 , 5 9 7 , 5 9 8 , 599 ,600 , 604, 605 ,606 , 608 electroosmotic mobility - 578, 579, 582, 590, 591 ,593 electrophoretic mobilities - 107 electrophoretic mobility - 5 7 8 , 5 7 9 , 5 8 2 , 590, 5 9 1 , 5 9 3 , 5 9 7 , 6 0 3 electrophoretic ve loc i ty- 578 e l emol - 550 Elemental nitrogen analyzer - 382 elimination reactions - 265 ellipticity - 123, 124 emulsifiers - 83 emulsions- 99 enatiomers - 101 endosperm - 53 endotherm - 69, 71 enometer - 14 entangled ne twork- 22 entanglement spectrum - 11 enzymatic-spectrometric me thod- 211 enzyme analysis - 62 Enzyme-linked Immunosorbent Assays (ELISA)- 106, 109, 116, 120 enzymic hydrolysis - 87 7-epialpha eduesmol - 551 epichlorohydrin- 88 10-epi-gamma eduesmol - 553 epi-illuminating - 109 epiphasic carotenoids - 354 equaligurim modulus - 12 equatorial - 101 equipment and columns - 356 Essential Oil Assoc.of America (EOA) - 350 essential o i l s - 2 6 3 , 2 6 5 , 2 7 0 , 295 esterification- 25

es ters - 303 ethanol - 196 2-ethoxy-3-ethyl pyraz ine- 5 0 7 , 5 0 8 ethyl acetate- 306, 307 ,312 , 320 ethyl capra te- 306 ethyl caprylate - 306 ethyl carbamate- 341 ethyl cinnamate (E) - 537 2-ethyl-3,5(or 3,6)-dimethylpyrazine- 285 3-ethyl-2,5-dimethyl pyraz ine- 229, 232, 233 ,237 ethylene glycol - 142 4-ethyl guaiacol - 545 ethyl hexadecanoate- 543 ethyl lactate- 325 ethyl laureate- 306 ethylmethylpyrazine- 232 2-ethylmethyl pyraz ine- 232 2-e thyl -5-methylpyraz ine- 287 ETU (ethylene thiourea) -440 , 441 ,442 , 445-463 Euchema cot toni- 127, 129, 131 Euchema spinosum - 128 Euclidian distance - 172, 174, 175 $-eudesmol - 552 $-eudesmol (eudesm-4(1,4)-en-11-ol) - 552 eugenol (4-allyl guaiacol) - 544 Ewers method - 111 extraction methods - 355 falling sphere- 75 far-infrared - 144, 190 fastlist - 496, 498 fat content - 51 fat mimetics - 195 fatty acid derivatizion - 197 fatty acid es ters - 306 fatty acid ethyl esters - 249 fatty acids- 71 F D A - 1 9 5 , 2 1 1 , 2 1 2 Fehlings solution - 111 F E M A - 503 ferricyanide me thod- 73 FFAP phase - 313, 315 filter instrument - 160, 180 Finland - 253

Page 636: Instrumental

fish oils - 206 flame ionization detector (FID) - 200, 201, 227 ,340 , 341 ,342 , 3 6 5 , 4 0 2 , 4 0 3 , 4 0 4 , 4 0 7 , 408 ,409 , 414, 415 ,416 , 478 ,481 flat sour spores - 87 f lavor- 99, 266, 267 ,268 , 294, 322, 323, 489 flavor encapsulation - 99 flavor release - 99 flax - 179 f luorescence- 109, 180 fluorescence detec tor- 606, 607, 608 fluorescence methods - 134 fluorophore - 607 foams- 99 Folch - 196 Folin-Ciocaltew reagent- 363 food ge l s - 99 food starch applications - 91 formates - 262 For t ran- 307 Fourier Transform infrared spectroscopy (FT-IR, F T - N I R ) - 105, 112, 142, 145, 151. 169, 172, 179, 184, 187, 188, 189,206, 209 fractional acid precipitat ion- 123 fractional precipitation - 104 fractional vacuum disti l lat ion- 323 fractionation - 113, 115 Fragaria - 253 fragrance(s) - 245 ,266 , 2 6 7 , 2 6 8 , 2 9 4 , A01 fragmentat ion- 2 4 5 , 2 4 7 , 2 4 8 frambinone - 522 free fatty ac ids- 312, 313 free vo lume- 36 freeze-thaw stability - 89 french fries - 209 f reon- 11,321 frequency shifting - 14 frictional force - 578 full malt - 306, 317 functional additive - 100 furaneol- 560 furanol - 253 furans- 2 2 8 , 2 2 9 furfural - 557

619

furfural ac id- 315 fused silica capillary columns - 306, 310 fused silica needle syringe - 331 fusel - 324 fusel a lcohols- 306 galactomannans- 25 Garces and Mancha - 198 Gardener color imeter - 349 gar l ic- 2 5 3 , 2 5 9 , 2 7 2 gas chromatographic analysis - 199 Gas Chromatography ( G C ) - 105, 120, 129, 130, 147, 177, 187, 195, 197, 199, 201 ,202 , 206, 2 0 8 , 2 0 9 , 2 1 1 , 2 1 2 , 2 4 9 , 253 ,260 , 303- 346, 3 6 1 , 3 6 3 , 3 6 4 , 365 ,367 , 370, 378, 387, 389, 390, 393 ,396 , 4 0 2 , 4 0 3 , 4 0 4 , 405 ,406 , 408, 409, 4 1 1 , 4 1 3 , 4 1 4 , 434, 490 Gaschrom- 307 gaussian distribution - 163 G C / P T V - 337 G C - E C D - 336 G C - F T I R - 294 G C - M S - 179, 245 ,249 , 256 ,260 , 336, 342, 493 G C - M S D - 336, 337 ,339 gel - 110 gel consistency - 83 gel filtration - 106 gel permeation chromatography - 104, 108, 112, 113, 116, 118 gelatin - 100 gelatine - 91 gelatinization- 52, 55, 63, 67, 69, 71, 110, 111 gelatinization temperature - 110 gelation-phase separat ion- 32 gelling - 12 ge ls - 12 gentle ionization techniques - 248 ,263 geran ium- 272 geranyl esters - 262 germ - 150 germacra-1 (10),4-dien-6-ol - 554 germacra- 1 (10), 5-dien-4-ol (germacrene d-4-ol) - 554 Germanium (Ge) - 183

Page 637: Instrumental

620

gernyl - 271 gernyl gernyl pyrophosphate (GGPS) - 352 Gerstel CIS-3 - 316, 332, 334, 339 Gibbs' dichoroquinonechlorimide reagent- 364 Gibbs phase rule - 108 Gigartina spp. - 127 glass capillary columns- 310 glass transition- 37 glass transition temperature - 99 glassy region- 12 GLC- 130, 134, 365 Gleenol- 509 glucoamylase - 69 glucopyranose - 86 glucosidase - 85 gluten - 150, 151 glycosidic linkage - 102, 105, 108, 110, 128 GP-HPLC - 114 granule - 110 grating monochromator- 150, 151, 160, 181, 182, 184, 187, 188 grating polychromator - 182, 184 Grob - 310, 328 guaiacol- 545 gum Arabic- 100, 114, 116, 118, 119, 120, 134 gum tragacanth - 134 Hagen-Poisenille equation - 603 Hammond - 196, 201 headspace- 225,226, 2 2 8 , 2 2 9 , 2 4 0 , 304, 3 1 7 , 3 3 1 , 3 3 2 , 341 headspace analysis - 225 ,226 , 228,229, 240 heat capacity - 99 heat stability - 99 heats of formation - 264 H E E T - 360 (E)-hel-2-en- 1-al - 517 (E)-hel-3-en-l-ol- 527 (Z)-hel-3-en- 1-ol - 527 Helichrysum stoechas - 506 hemiacetal - 102 henanal- 229, 2 3 1 , 2 3 3 , 2 3 6 , 240 heptadecanoic acid - 198 Herraiz- 327

Hessian Bordeaux - 113 heteroannular dienes - 249 heterogenous structure - 49 heterocyclic compounds - 230 N-heterocyclics- 230, 247,248, 303 ,304 O-heterocyclics- 303 heteropolysaccharide - 101 hetertypic- 25 Hewlett -Packard 5880A - 310 hexamethylene polymer solution- 135 hexanal - 517 n-hexane- 142, 145, 146, 148, 151, 196 hexanoates- 262 high performance liquid chromatography (HPLC)-62, 101, 105, 147, 177, 182, 186, 206, 209, 348, 349, 354, 355,356, 357, 361, 362,364, 365,366, 367,368, 369, 370, 378, 434, 435 ,436, 4 3 7 , 4 3 8 , 4 4 0 , 441,442-464 high performance size exclusion chromatography (HPSEC) - 116 high resolution mass spectrometry - 248 high solid biopolymer systems - 34 high-solids food biopolymer systems - 40 hilum - 53 Hizuluri - 114 H - N M R - 105, 124, 125, 132, J40 holographic gratings - 182 homogeneity - 104 homopolysaccahrides - 101 homotypic - 25 Hooke's Law- 3 hot needle technique - 200 Huggins - 19, 20 Hunter Miniscan- 349 Hunter reflectometer - 72 hybr id- 133 hydride ion- 264 hydrocarbon(s)- 145, 146, 150, 248,249, 2 6 4 , 2 6 5 , 2 7 2 , 303,491 hydrocolloids- 49, 99, 100, 110, 133 hydrocrakite hydrocarbon standard - 408, 409 hydrodynamic- 11,603 hydrodynamic injection - 603 hydrogen bonding - 265

Page 638: Instrumental

hydrolytic degradation - 72 hydrolyzed starches - 87 hydrostatic f l o w - 577 hydroxyl compounds - 303 5-(hydroxymethyl) fur fura l - 559 3-hydroxyl-4-phenyl-2-butanone- 523 hydroxylpropyl - 86 hygroscopic - 53 hyperentanglement - 11 immunoassay- 120, 203 immunoblotting - 116 immunological - 109 in situ - 109 in vitro - 3, 111 i n v i v o - 2 , 111 Inclusion complexes - 599 indica- 52 Indium, Gallium, Arsenide (InGaAs) - 182, 183, 186 infrared ( IR) - 130, 155 ,342 rejection technique - 200 rejection-extraction procedure - 368 interference filter - 180, 181 mterferometer - 184, 187, 188, 189 intermediate f ract ion- 51 interpenetrating networks - 23, 24 intrinsic viscosity - 18, 19, 75, 104 ~odine affinity - 52 ~odine complexes - 51 xodine va lue - 147, 177, 178 I O F I - 503 ion co-elution test - 318 ion-exchange chromatography - 104 ion ratio test - 318 ion trap - 2 6 2 , 2 6 3 , 4 9 1 , 5 0 6 ion trap MS (ITMS) - 262 ,263 ~on trapping - 2 6 2 , 2 6 3 , 4 9 1 , 5 0 6 ~onic interactions- 24 ~onic species - 154 ~onization voltage - 491 isatachopherograms - 107 ~satachophoresis - 107 ~soamyl acetate - 312 ~sobutane- 263 ,264 , 2 7 1 , 2 7 2 2-isobutyl-3,5(or3,6)-dimethylpyrazine -

621

290 2-isobutyl-3(or 6)-methylpyrazine - 289 2-isobutyl-5-methylpyrazine- 288 iso-butanol- 306, 312 isoelectric po in t - 28 isolate (isolation, isolated) - 225 ,226 , 227, 2 2 8 , 2 3 3 , 2 3 4 , 240 isolation of starch - 50 i somers- 206, 208 ,209 , 211 ~sooctane - 142, 328 ~sopentyl a lcohol - 253 ,260 , 261 ~sopentyl t r imethylpyrazine- 568 lsopropanol- 196 (see 2-propanol) lsostrain- 27, 28 ~sostress - 611 isotopic variations - 104 japonica- 51, 52 jasmine lactone (delta jasmolactone) - 535 jessies - 91 Joint Expert Committee for Food Additives ( J E C F A ) - 117, 120 Joule hea t ing- 576, 584, 585 ,586 , 587, 588 ,590 , 591 ,594 , 604 jun ipe r - 2 5 3 , 2 5 6 , 2 7 2 Kal t ron- 321, 325 ,326 , 329 "-kaurene- 556 "-kaurene (kaur-16-ene) - 556 ke tones- 2 2 8 , 2 2 9 Kjeldahl nitrogen method - 383 K o l b - 332 Kosuge and Inagaki - 363 Kovats indices (KID or KI) - 2 4 5 , 2 4 8 , 2 4 9 , 250, 251 ,252 , 253 ,254 , 2 5 5 , 2 5 8 , 4 9 0 , 494, 4 9 9 , 5 0 1 , 5 0 3 , 5 0 6 , 510, 511 Kovats indices calculation - 510, 511 Kraemer - 19 L*A*B* system - 349 lactones - 253 ,303 lamb b ro th - 211 laminar flow - 19 Laminaria hiperborea - 121 Lane and Eynon method - 112 large volume inject ion- 305, 3 2 1 , 3 2 5 , 3 2 7 , 328, 332, 341 laser induced fluorescence - 608

Page 639: Instrumental

622

lauric acid - 212 lavender lactone - 533 lead sulfide (PbS)- 158, 180, 185 lectins - 105 Lee - 114 legume starches - 85, 86, 87 light blended - 306, 319 light cycle oil (LCO)- 4 0 2 , 4 0 8 , 4 1 0 , 412 light emitting diode (LED) - 181 light scattering - 104 cis-linalool oxide - 274, 275 (E)-linalool oxide- 276 trans linalool oxide- 276, 277 (Z)-linalool oxide - 274 linayl esters - 262 linear alkanes- 248 ,253 linear ethyl esters - 248, 253 linear homopolymeric structures - 101, 102 linear programmed temperature- 248 linear viscoelasticity - 4 linoleic acid - 147,204, 205, 211 lintiner starch - 88 lipid extraction - 195, 196 lipid(s)- 49, 73, 103, 106, 142, 145, 149, 151, 177, 178 lipoprotiens - 196 liquified petroleum gases (LPG) - 416, 417, 419, 421 liver - 211 Lovibond t intometer- 71 low angle laser light scattering photometer (LALLS) - 114 low fat - 45, 99 low fat spreadable products - 45 lycopene - 353 Mac Micael- 75 Macrocystis pyrifera - 121 macromolecular - 27, 68, 109 magnetic- 247 Mahalanobis distance - 172 Maillard reaction- 248,249, 335 maize- 53, 54, 55, 56, 62, 69, 701 73, 74, 78, 79, 80, 81, 82, 83, 84, 86, 88, 90 Malagasy- 257 mal t - 306, 314

maltodextrin - 1, 32, 33, 45, 110, 111, 114 mango- 205 ,206 margarine- 208 maricultured - 127 mass fragmentographic method- 365 mass fragmentographic SIM - 253,254, 2 5 5 , 2 5 7 , 2 5 9 mass selective instability - 262 mass spectra- 4 9 1 , 4 9 3 , 5 0 3 mass spectrometry (MS) - 105, 129, 130, 206, 2 0 7 , 2 1 5 , 2 2 7 , 246, 253,256,260, 294 ,295 ,317 ,336 , 337 338, 3 4 2 , 3 6 3 , 3 6 5 , 489, 608 ,610 MS/MS - 294 mastercurve- 38, 37 Masuda - 313 matrix removal- 305 ,320 Maxwel l - 3, 4, 5 McDonald- 209, 211 MDCG-IRMS - 294 measurement geometries - 1 5

measuring Chile capsaicinoids - 361 mechanical drying - 61 mechanical spectra - 40, 42 methane- 263,264, 270, 271 methional- 530 methoxybromomercruic adducts - 206 2-methyloxy-3-(2-methylpropyl) pyrazine- 567 N-2-methylbutyl acetamide - 515 N-3-methylbutyl acetamide - 515 cis-methyl chrysantemate- 538 methyl esters- 2 5 1 , 2 5 2 , 2 5 3 methyl eugenol- 547 methyl eugenol (methyl, cumate, chavibetol, methyl ester- 547 cis, cis methylene-uninterrupted- 195 5-methylfurfural- 278 ,280, 557 2-methylfuroate- 560 methyl hexadecanoate - 543 methyl silicone- 249 methyl silicone copolymer of EGS (EGSS-X) - 199 methylation analysis - 106 methylene chloride - 196

Page 640: Instrumental

623

methylpyraz ine- 282 MFE-Vin ico l - 309 micellar electrokinetic capillary - 590, 597 microbial- 100, 104 microbiological methods - 87 mic roco lumn- 4 4 1 , 4 4 2 , 4 4 4 , 4 5 2 microencapsulat ion- 25, 99 microscope photometry (MP) - 109 microscopy- 109 microspectrometer - 180 microspectrophotometry - 109, 113 microspherical cellulose - 112 mid-infrared(mid-IR) - 141, 143, 144, 145, 147, 150, 151, 152, 153, 157, 158, 159, 160, 172, 180, 185, 187 m i l k - 157 ,209 m i l o - 74 Milolta ch romamete r - 349 mineral salts - 103 minerals - 49 mixed biopolymer systems - 27, 28, 29 mixed junction - 25 mobile phase (MP) - 4 4 2 , 4 6 4 mod i fy - 499, 500, 503 moiety - 270, 271 moist heat t rea tment - 62, 71, 74, 77, 79, 80, 81, 82, 84, 85, 87, 90 molecular diffusion- 584 Moneam and G h o n e i m - 205 monoclonal antibodies - 105 monodisperse - 104 monofunctional - 89 monogastric - 85 monoterpene - 491 monoterpenoid- 2 5 3 , 2 5 7 , 2 6 5 , 2 9 5 monounsaturated - 195, 199 cis-monounsaturated - 195 mouthfee l - 99 M S G - 4 5 8 , 4 6 3 , 4 6 4 MS-KI bank - 492 MTBEC4 food stream and depropanizer- 4 1 6 , 4 1 7 , 4 2 1 multi band TLC - 364 Multidimensional Gas Chromatography - 335

multiple linear regression - 165, 168, 171 multiple nearest neighbor (MNN) - 116 multi-variable statistics - 142 mult ivar ia te- 227, 228, 231 ,232 , 233 ,234 , 2 3 5 , 2 3 7 , 2 4 0 muscle f ibers- 99 microscopic analysis - 52 native starches - 110 natural emulsifier - 114 near-infrared (NIR) - 109, 112, 141-194 negative chemical ionization (NCI) - 263- 2 7 1 , 2 7 8 , 2 9 5 neryl - 271 n e w - 5 0 1 , 5 0 2 , 5 0 3 new compound - 502 Newtonian - 40 Newtonian Plateau - 22 Newton 's L a w - 3 nitrogen containing analytes- 389, 391 ,392 , 394, 395 ,396 , 398, 399, 402 Nitrogen to Carbon Selectivity (N/C) - 389 N'Nitrosonornicotine - 422, 424 nitroteraphthalic acid - 313 non-endosperm material - 151 non-fat dry m i l k - 143 non-linear viscoelasticity - 4 nonpolar columns - 248 ,249 , 2 5 1 , 2 5 3 , 2 5 4 non-polar KID - (KIA) - 494, 495 ,501 non-solvent splitting inject ion- 325, 331, 332 nordihidrocapsaicin- 362, 365 Novolose - 111 Nuclear magnetic resonance spectroscopy ( N M R ) - 105, 112, 113, 117, 120, 123, 124, 125, 132, 179, 180, 206, 207 ,208 , 209 Nucleosides - 459 N u k o l - 202 Nulceot ides- 4 5 9 , 4 6 1 , 4 6 2 oak barre ls - 303 oa t s - 205 observed mobility - 578 octane - 183 octanoic - 313 octanol -148 odour intensities - 312

Page 641: Instrumental

624

olefins- 270 oleic acid- 146, 147 ,203 ,204 , 205,211 oleoresin capsicum - 364 oleoresin- 350, 361 ,366 olfactory- 370, 489 olfactory thresholds - 489 Olsson - 201 open tubular columns - 306 optical rotation - 111 organoleptic- 361,366, 370 orthogonallity - 163 orthophosphate- 89 oscillatory - 7, 10 osmometry - 62 osmotic pressure - 104 oxidation process - 49 oxidized starch- 89 3-oxo-alpha-ionol- 526 3-oxo-4-(benzyl) pyrrololactone- 569 3-oxo-4-(1-methyl) pyrrololactone - 569 packed column - 310, 312 paired T ' tes ts - 228 pa lm- 209 palmitic- 203 ,204, 205, 211 pancreatic - 85, 86 paper chromatography- 363 ,370 paprika- 348, 350, 363 n-paraffin- 248 parallel plate- 15, 17 partial acid hydrolysis - 123 partial least squares (PLS) - 166, 169, 170 partially methylated alditol acetates - 106 pastilles - 91 pattern recognition - 490 pea - 110 pectin- 91, 134, 135 pentadecane- 226, 227, 231 2-pentadecanone- 525 periodate oxidation- 62 permanent coating - 588 ,589 phase behavior- 99 phase damage - 327 phase separated networks - 26 phase solubility analysis - 108 phase sensitive amplif ier- 180

phase-separated networks - 23 phenethyl esters - 262 phenol - 108 phenol-sulfuric acid - 128 phenomenological - 6 phenylacetaldehyde- 229, 2 3 1 , 2 3 3 , 2 3 5 , 240 N-$-phenylethyl acetamide- 516 $-phenylethyl benzonate- 542 phenylmethyl- 227 Phenylmethyl silicone- 313, 324, 333,342 1-phenyl- 1,2-propanedione - 523 phosphate - 49, 73 phosphorus oxychloride - 88 phosphorylase- 85 photodiode detectors - 182 photometry - 62, 71 Photomultiplier tube (PMT) - 381,387, 393, 404, 4 0 8 , 4 2 8 , 4 4 2 , 4 5 8 , 464, 474 photovoltaic devices - 183 phycocolloids- 121, 126 physical methods of starch analysis - 52 physicochemical properties- 49, 50, 99 phytoene desaturase (PDS) - 352 P I D - 200 pimento- 363 p indak bean- 84 pinto bean- 84 pituitous - 49 plarimetry - 62 plastic properties- 99 Poisson's rat io- 7 polar columns - 248 ,249, 254 polar KID (KIP) - 494, 495,501 polybutanediol succinate (BDS) - 199 polydiethyleneglycol succinate (DEGS) - 199 polydisperse - 104 polydispersity - 11 polyethelene glycol- 307 polyethyleneglycol adipate (PEGA) - 199 polyethyleneglycol succinate (EGS) - 199 polymannuronate r ibbons- 25 polyneopentylglycol succinate (NPGS) - 199

Page 642: Instrumental

625

polysaccharides- 1, 2, 12, 99, 100, 101, polyunsaturated - 195, 197, 199 pork- 203 porous glass beads - 112 positive chemical ionization (PCI) - 263- 272,295 potato- 49, 51, 52, 53, 62, 68, 69, 72, 74. 76, 81, 84, 86, 90, 91, 110, 112, 113, 115 potato starch - 112, 113 ppb - 341 pre- ethanols - 320 precolumn backflush - 320 pregelatinization - 49, 110 preparative chromatography- 322 ,340 P R I / C L N D - 378 principal component analysis (PCA) - 117, 169, 170, 228, 231 principal component regression- 166 principal fragmentation patterns - 247 primary alcohols - 493 propanol- 306 n- 1-propanol - 148 proplene oxide - 89 propylene - 142 Prosopis - 116 protein matrix - 49 protein(s)- 49, 52, 99, 102, 103, 105, 106, 110, 142, 145, 147, 149, 150, 151, 152, 176, 177 proton transfer reactions - 264 P T V - 327-337,339, 341 pullulanases - 114 pullulans - 104 pungency- 347,348, 359, 370 purge- 226, 2 2 7 , 2 2 8 , 2 3 1 , 2 3 2 , 2 3 3 , 2 3 4 , 2 3 5 , 2 3 7 , 2 3 8 purge-and-trap technique - 2 2 5 , 2 2 8 , 2 2 9 purity - 103, 104, 107, 108 pyranone- 230, 232 pyranose - 101 pyrazines- 228 ,229 pyro-chemiluminescent- 378, 381,383 pyrofurnace - 480 quadrupole- 2 4 7 , 2 5 3 , 2 6 2 , 4 9 1 , 5 0 6 quadrupole filters- 262

quadrupole mass filter method - 253 qualifier ions - 319 quartz tunsten halogen source - 180 quasimolecular ions - 263 ,278 quasimolecular masses - 295 (-radiation- 73 radioactive reagents - 106 radiometry - 62 Raman Spectroscopy - 179, 180 random coil conformation- 55, 74 randomized- 227 rapid TLC - 365 rate of sedimentation - 52 Red chil i- 348 red millet- 74, 84 Reducing power - 73 reference spectrum - 247 refinery systems- 430, 431 ,462 reflectance - 156 reflection- 156, 157, 159 refraction - 156, 157, 159 refractive index (RI) - 104, 105, 116, 120, 156, 159 regression - 161, 162, 165, 166, 167, 169, 170, 171, 177 regular alternated linear structures - 101 relative affinity - 32 Repeatability standard deviation (RSD) - 383 resistant starch (RS) - 111 resolution- 589, 590, 600 retention indices - 249 retention times (RT) - 227 ,230, 239, 248, 358 ret ina- 207 retro-aldolization- 270 retrogradation - 49, 83, 110, 111 reverse solvent effect- 312 reversed phase chromatography - 207, 356, 357,366, 3 6 7 , 4 3 9 , 4 5 9 , 460 reversed phase TLC - 207 rheological methods- 73 rheological properties- 77 rheology- 1, 2, 10, 14, 18, 99 rheometers- 50, 80

Page 643: Instrumental

626

rhisobium trisolii- 20 rice- 49, 50, 51, 52, 53, 54, 56, 57, 62, 63, 68, 69, 70, 73, 74, 76, 77, 78, 79, 81, 82, 86, 87, 110, 177 robust(ness) - 161, 166, 167 rotary valve - 320 RP-HPLC (reversed phase HPLC)- 439, 459, 460 rum- 303,304, 308 sabiene- 263 sago palm - 86 Sahasrabudhe- 205 "-santolina alcohol- 529 santolina alcohol - 529 santolina triene - 512 saponification- 1 9 7 , 2 0 2 , 2 0 3 , 2 0 9 , 211, 354, 355 saturated spectra - 247 sausage - 211 save- 503 Scanning Electron Microscopy (SEM)- 53, 54, 55, 56, 57, 58, 59, 60, 61 Scanning instruments - 181 SCD- 340, 342 Schinus terebenthifolus berries- 205 Scoville heat uni t - 361,366 Scoville Organoleptic Test- 361 seaweeds- 100, 121, 122, 126 SEC (size exclusion chromatography)- 378, 464-476 secondary alcohols - 493 sedimentation - 104, 106, 107 sedimentation equilibrium - 107 sedimentation velocity - 107 selected ion monitoring mode (SIM) - 317, 319, 341 semiconductor laser fluorimetry - 604 Sengal Number - 116 sensitivity- 263 sensory properties - 99 Senter- 205 Separation and quantification of capsaicinoids- 363 sesaviterpenic - 491 sespuiterpenoid - 2 5 3 , 2 5 7 , 2 7 0

trans-$-sesquiphellandrol- 555 sesquiterpene- 248,270, 271,272, 295 SF (super fluid) - 479 shear - 6 shear thinning - 11, 22 signal-to-noise ratio - 143, 144, 147, 160, 186, 187 silanized - 226 Silar 5CP - 199 silica gel plates- 364 silicon photodiode array(s) - 182, 183 silicon - 199, 227 silicon detectors - 181 silicon polymers - 199 silicic acid column chromatography - 197 Silocosteel- 308 silyl derivatives- 365 SIM- 248, 253 ,256 SimDis- 378 simple linear regression - 165 simulated distillation- 430, 431 ,432 sinusoidal drive strain- 9 size exclusion permeation chromatography - 104 Sloan's liniment- 360 Slover and Lanza - 209 small deformation oscillatory measurements - 7 , 1 7 smoluchowske equation- 579 sodium borohydride- 109, 358 sodium tripolyphosphate - 89 sol-gel transition - 40 solid fat index- 147, 177, 178 Solid phase extraction (SPE) - 327 solubility- 73, 74 solvent distribution - 31 solvent splitting - 327, 330 solvent venting - 327, 329, 330 sorghum- 75, 84 soxlet extractions - 196, 205 soybean oil - 209 specialized direct injection techniques - 320 specific viscosity- 19, 20 SPECMA- 489, 4 9 0 , 4 9 3 , 4 9 6 , 4 9 7 , 5 0 7 , 513

Page 644: Instrumental

627

spectrophotometric - 51 spectrophotometry- 347-374 spectroscopic- 142, 143, 152, 163, 164, 165, 166, 167, 172, 175, 176, 177, 178, 180, 182, 183, 184, 192 spores - 87 spot tests - 133 Stabilwax-DA- 202 standard error of difference - 162 standard error of calibration - 165, 166, 167 standard error of performance - 166, 177 starch- 34, 51, 89, 110, 111, 150, 151, 176 starch composition - 51 starch modification methods - 87 starch molding - 34 starch phosphate products - 89 stationary liquid phases - 199,200 stationary phases- 199, 389, 391,394, 395, 397,398, 399 steady shear - 18 stearic- 100, 203,204, 205,206, 211 steeped- 55 stereoisomers- 270, 360 stereoisometric- 270 straight-chain- 248 strain- 2, 4 strawberry - 253 stress- 2, 4 Stromer - 75 structural analysis - 116 subfamily- 503 substitution - 49 substance p - 360 substitution reactions - 265 substituted starch- 89 sulfur- 325,326, 341 ,342 sulfur compounds - 228 ,230 sunflower- 209 supercritical fluid chromatography - 197, 205 ,379 support coated open tubular (SCOT) - 199 surface activity - 99 surface color- 348, 349 surfactant- 598,599, 600, 606 sweet potato- 51, 52, 53, 62, 68, 74, 83, 84,

86 swelling power - 73, 74 swish purification - 108 synersis - 83, 84 synthetic analogs - 362 synthetic vanillylamides- 364 Syrah wine- 260, 261 takayanagic- 27, 30 Taniguchi- 325 tapioca- 49, 55, 72, 88 tapid taste fatigue - 361 tapioca - 110, 115 target compound analysis - 318 Tbanque - 496 T C D - 200 tellurium dioxide (TeO2) - 185 Tenax- 329 T e n e x - G C - 226, 231 ,232, 234, 2 3 7 , 2 3 8 , 239, 240 tension - 6 Ter Heide - 322 terpene- 248,270, 271 ,272 terpenoid- 304 terpenoid esters - 271 terpenoid hydrocarbons- 265 tetradecane- 226 tetramethylammonium hydroxide - 198 tetramethylpyrazine- 567 tetraterpenoid - 352 theoretical plates- 584, 585 thermal desorbtion- 3 0 5 , 3 1 7 , 3 3 7 thermal field flow fractionation- (FFF) - 104, 113, 115 thermodynamic incomparability - 26 thermodynamic properties - 99 thermolabile- 329 thialdine- 565 thin layer chromatography (TLC) - 202, 2 0 6 , 2 0 7 , 2 0 9 , 2 1 1 , 3 5 3 , 3 6 3 , 3 6 4 , 365 ,370 three dimensional quadrupole mass spectrometer- 262 thylakoid membranes - 352 thymol- 546 "-thryene (origanene) - 513 T I C - 318

Page 645: Instrumental

628

tiglates- 262 TMS-GC- 367 toluene- 146, 147, 185 topologies- 23 total free sugars - 108 Total Nitrogen Analysis - 381 ,383,384, 385 total pigment content- 350 Tpics - 496 transesterification- 197,202,205, 212 tricyclene - 513 2-tridecanone- 525 trifluoroacetate esters - 129 trigeminal innervation- 347 triglycerides - 197 trilinolein - 211 trimetaphosphate- 88 2,4,5-trimethyl oxazole- 561 2,4,5-trimethyl-3-oxazolines (two isomers) - 561 trimethyl pyrazine- 229, 231 ,232 ,233 , 237, 286 2,4,5-trimethyl-3-thiasolines (two isomers) - 562 trimethylthiazole- 562 trimethylsilyl (TMS)- 109, 365 trimethylsilyl derivatives - 365 2,4,6-trimethyl- 1,3,5-trithiane - 564 t-test - 165, 166, 167 tungsten- 158 Turbo Pascal- 278,489, 495 turnip- 205 two dimensional chromatography - 305, 338, 341 two-dimensional hyphenated system - 336 ultracentrifugation - 104, 106, 107 ultraviolet-visible detector - 602, 603 uniaxial compression - 6 unknown- M W - 155 - 232 ,233 ,236 , 240 urea adduct method - 207 urea - 89, 207 uronic acid - 105 USDA - 180, 184 UV(ultraviolet)- 105, 116, 120, 124, 143, 144, 180, 182, 192, 365,366, 367, 368,424,

437 ,438 ,442 ,450 , 451,454-457,459, 468, 481 UV detection- 424, 437, 438 ,442 ,450 , 451,454-457,459, 468, 481 UV-vis- 356, 367 Vaccinium- 253 valveless technique - 336 van tier waals forces - 588,594 vanadium oxytrichloride - 362 vanillin- 359, 362 vapor overflow - 327 Villen- 327 vinyl acetate- 89 2-vinyl (4H)-l,3-dithiin- 563 3-vinyl (4H)-l,2-dithiin- 563 vinylphenol- 230, 2 3 1 , 2 3 3 , 2 3 5 , 2 4 0 viscoelastic - 80, 99 viscoelasticity- 3, 7, 9, 27, 28, 34 viscometers - 16 viscosity- 37, 42, 43, 44, 45, 53, 75, 76, 77, 79, 80, 87, 88, 89, 90 viscosity profile- 50 visible region- 144, 182 Vogt- 327 Voigt- 3, 4, 5 volatile- 225,226, 227, 228, 230, 231,232, 233,234, 236, 237, 238, 240 volatile fragrant compounds - 245 wall coated open tubular (WCOT) - 199 walnut- 205 water binding capacity - 84 waxy maize - 110 3-way factorial- 227 weak-gels- 12, 17 wet product - 368 wheat- 49, 55, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 72, 73, 76, 81, 90, 91, 110, 150, 151, 152, 176, 179 whiskey- 303,304, 306, 307, 310, 311, 313,314, 315 ,317 ,324 , 325,329, 335,341 whiskey new distillates- 325 wide angle X-ray diffraction (WAXS) - 113 Williams and Macgee - 198 Williams-Landel-Ferry Kinetics (WLF) - 34, 36, 4 0 , 4 3

Page 646: Instrumental

629

Windows- 336, 489, 490, 495 W y l i e - 332 xanthin - 12, 135 xanthonphyl ls- 3 4 7 , 3 5 3 , 3 5 4 X-ray diffraction - 62, 63, 113 X-Rite 918 - 349 xylene - 146, 147 xylene displacement method - 55 yeast mannans - 108 yomogi a lcohol - 528 Young's modulus - 6, 7 Yugoslavian- 257 Yxy color space- 349 Zeichmeister and Cholnoky - 353 zero shear - 20, 21, 23 zeta potential - 579, 580, 582 ,584 , 588 zingiberenol - 555