instrumentation for the wastewater treatment · pdf filecommon features of royce products...
TRANSCRIPT
Instrumentation for the Wastewater Treatment Industry
COMMON FEATURES OF ROYCE PRODUCTS•Microprocessorbased,self-diagnosingelectronics
• Rugged,mil-specelectroniccomponents
•Onestep,automaticcalibration
•Analoganddigitaloutputcommunications,including
multipleBUSSoptions
• Programmablesetpointsandsolidstaterelays
• Spaceagecompositesensormaterials
• Polymer,unbreakablesensoroptics
•Colorcompensatingoptics(TSS)
• Selfcleaningsensorsthroughoutthelineofproducts
• Intelligent,menudrivensetupandoperation
• Enclosuresunscreens(Optional)
• Sensorfaultfeedbackonallcontrollers
• Backlitdisplays
RoyceTechnologiesInstrumentationLine
MEASUREMENTTECHNOLOGIESBYROYCEDissolved Oxygen Monitoring and Control• SingleandMulti-channelAnalyzers
• BioreactorandLagoonSystems
Total Suspended Solids Monitoring and Control• PortableAnalyzers
• SingleandMulti-channelAnalyzers
• Solidsdensity
Interface Level analyzers• Primary,SecondaryandThickenerAnalyzers
2
Model 9110/9120/9210/9220 Analyzer
Model 9200 Analyzer
GalvanicPartsPerMillionDissolvedOxygenSystems
3
Features
• Single&DualChannels
•Onestep,pushbuttoncalibration
•DisplaysDO&temperatureforeachchannel
• Two4–20mAperchannelforDOandtemperature
• Tworelaysperchannel
• RS–485&Modbus(Standard)
•ProfibusDP(Optional)
Features
• Range0–99.9PPMandpercentsaturation0–99.9%
•Onestep,pushbuttoncalibration
• Twomethodsofcalibrationarestandard
•AutomaticTemp,altitudeandsalinitycompensation
• Isolated4–20mA
•Digitalserialoutputavailable
Features
• Twocompleteanalyzersinone
package(TSS&InterfaceLevel)
• Onesensorforbothapplications
• Microprocessorbased
• AutomaticRanging
• Simple,insitucalibration
• Electronicselfdiagnostics
• Ninevoltbatterywithautomatic
shutoff
• Waterproof,completelysubmersible, ruggedhousing
Features
• Single&DualChannels
• Automatic,pushbutton,insitu calibrationtoaknownvalue
• Range10–80,000mg/l
• Measuredrangedependsonsensor
• 72Series:10–1500mg/l
• 73Series:300–30,000mg/l
• 74Series:800–80,000mg/l
• 76Series:300–30,000mg/l
• Two4–20mAperchannel
• Tworelaysperchannel
• RS-485&Modbus(Standard)
•ProfibusDP(Optional)
Features
• Automaticranging
• 10to80,000mg/l
• Phasedarraysourceforautomatic colorcompensation(Model73B)
• Automatic,pushbutton,insitu
calibrationtoaknownvalue
• Automaticambientlightcompensation onallmodels
• Userselectablecalibrationcurves
• TwoProgrammablesetpointrelays
• Outputs4–20mA.0–1VDC(isolated)
• RS-485(Standard)
Model 711Portable MLSS/ILA System
Model 7110/7120 SeriesAnalyzer
Model 7011AContinuous Analyzer
4
TotalSuspendedSolidsSystems
Features
•Measuresbothinterfaceandclarity
•Nomovingparts,nomaintenance,norecalibrationrequired
• Surfaceskimmerfriendly
•Microprocessorbasedelectronics
• BacklitLCDdisplays
• Fullfeaturedsetpointrelaysavailable
• Simpleuserfriendlymenudrivenprogramming
•Numericalandgraphicaldisplays
Models 2511A Analyzer
Features
•Onechannel,twochannelandfourchannelsystemsavailable
• Utilizesthehighestgradecompressoravailable
Features
•CanbeusedonanyRoycesensor
• CanbecontrolledbyaRoyceanalyzerorcontroller
• Thousandsinuseworldwide
5
Model JC-1 Compressor (Single Channel)
Model JC-4 Compressor (FOUR Channel)
InterfaceLevelAnalyzer
JCSeriesCompressorCleaningSystems
Influent Structure Primary Clarifier
ILA
SS3
SS1 or SS2
DIGESTER
DEWATERING SUPERMATENT
DEWATERING
RETURNACTIVATED SLUDGE
ILAGRAVITY THICKENER
OPTIONALDIRECT DISCHARGE
(LANDFILL, COMPOSTINCINERATION)
DEWATEREDSOLIDS
WASTE ACTIVATED SLUDGE
PLANT DISCHARGE CHANNEL
Secondary ClarifierAeration Basin Disinfection
GRA
VIT
Y TH
ICK
ENER
SU
PERM
ATE
NT
DO SS2
SS3
ILASS1 DO SS1
DO – Dissolved Oxygen
SS1 – Suspended Solids Low Range < 50mg/L
SS2 – Suspended Solids Medium Range 1,000 to 20,000 mg/L
SS3 – Suspended Solids High Range to 8%
6
PROCESSCONTROLINSTRUMENTATIONATATYPICALSECONDARYWASTEWATERTREATMENTPLANT
Influent Structure Primary Clarifier
ILA
SS3
SS1 or SS2
DIGESTER
DEWATERING SUPERMATENT
DEWATERING
RETURNACTIVATED SLUDGE
ILAGRAVITY THICKENER
OPTIONALDIRECT DISCHARGE
(LANDFILL, COMPOSTINCINERATION)
DEWATEREDSOLIDS
WASTE ACTIVATED SLUDGE
PLANT DISCHARGE CHANNEL
Secondary ClarifierAeration Basin Disinfection
GRA
VIT
Y TH
ICK
ENER
SU
PERM
ATE
NT
DO SS2
SS3
ILASS1 DO SS1
DO – Dissolved Oxygen
SS1 – Suspended Solids Low Range < 50mg/L
SS2 – Suspended Solids Medium Range 1,000 to 20,000 mg/L
SS3 – Suspended Solids High Range to 8%
PROCESSCONTROLINSTRUMENTATIONATATYPICALSECONDARYWASTEWATERTREATMENTPLANT
7
151GrahamRoadPOBox9010CollegeStation,Texas77842-9010
(979)690-1711(800)653-1711USA/CanadaFAX(979)690-0440
www.roycetechnologies.comE-mail:[email protected]
Publication 37590512
MEASUREMENT TECHNOLOGIES BY ROYCE
Dissolved Oxygen Monitoring and Control• SingleandMulti-channelAnalyzers
• BioreactorandLagoonSystems
Total Suspended Solids Monitoring and Control• PortableAnalyzers
• SingleandMulti-channelAnalyzers
• Solidsdensity
Interface Level analyzers• Primary,SecondaryandThickenerAnalyzers
Royce,aXylembrand,provideshighqualitymonitoringandcontrolinstrumentationandsensorsspecificallydesignedformunicipalandindustrialwastewatertreatmentapplications.Recognizedthroughoutthewastewatertreatmentindustryasexpertsinthebiologicalwastewatertreatmentprocess.