instrumentation power supplies - · pdf file11 kepco instrumentation power supplies...
TRANSCRIPT
10KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11352 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102
Email: [email protected] • www.kepcopower.com
I N S T R U M E N TAT I O N P O W E R S U P P L I E S
UNIPOLAR POWER SUPPLIES14
BIPOLAR POWER SUPPLIES43
SPECIAL PURPOSE POWER SUPPLIES61
ACCESSORIES & HARDWARE77
11
KepcoInstrumentationPower SuppliesCharacteristicSelection ChartsThe five charts that follow summarizethe principal characteristics of Kepco’sinstrumentation type power supplies.
Tables are included for their programmingcharacteristics (analog and digital), their physicalcharacteristics, electrical output characteristicsplus output power and voltage ranges.
The purpose is to help you select an appropriatepower supply for your application and to pointyou toward the correct pages in this catalogwhere a full description may be found.
The digitally controlled power supplies requiresome additional explanation as there are manymodes of communication (RS 232, IEEE 488.2and Kepco’s single address, multiple instrumentserial bus). A number of Kepco accessoriestranslate between buses and link various powersupplies to the common host computers usedin test systems.
A N I S O 9 0 0 1 C O M P A N Y
Kepco’s facility in Flushing, New York, hasreceived ISO 9001 certificate number 109592from Lloyd's Register of Quality Assurance.
(1) Requires the use of an external programming accessory.(2) Requires internal card BIT TMA-27.(3) Requires internal card BIT 4882 or BIT 4886.(4) Requires plug-in interface MST 488-27.(5) Requires internal card BIT 232.(6) Programmable by voltage, not isolated.
PROGRAMMING CHARACTERISTICS
BHK-MG
ABC
ATE
ATE-DMG
JQE
MAT
MPS
MSK
MST
BOP HIGH
BOP
BOP-HV
HSF
HSP
PRR
TBC
15
19
22
28
31
34
36
38
40
44
50
56
62
67
72
74
•
•
•
•
•
•
•
•
•
•
•
•
•
• (6)
•
•
•
•
•
•
• (1)
• (4)
•
• (5)
•
•
•
• (2)
•
•
• (1)
•
• (1)
• (1)
• (4)
•
• (3)
• (1)
AnalogOperational
DigitalIEEE 488
AnalogFast
DigitalRS 232
Multi-Instr.Serial Bus
AnalogResistance
PageIndex
Design Group
UN
IPO
LAR
BIPO
LAR
SPEC
IAL
PURP
OSE
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11352 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102Email: [email protected] • www.kepcopower.com
12
A N I S O 9 0 0 1 C O M P A N Y
PHYSICAL CHARACTERISTICS
BHK-MG
ABC
ATE
ATE-DMG
JQE
MAT
MPS
MSK
MST
BOP HIGH
BOP
BOP-HV
HSF
HSP
PRR
TBC
15
19
22
28
31
34
36
38
40
44
50
56
62
67
72
74
WallMount
RackMount
Plug-inRack
BenchStyle
PageIndex
Design Group
UN
IPO
LAR
BIPO
LAR
SPEC
IAL
PURP
OSE
• (1)
•
• (2)
• (3)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ELECTRICAL OUTPUT CHARACTERISTICS
BHK-MG
ABC
ATE
ATE-DMG
JQE
MAT
MPS
MSK
MST
BOP HIGH
BOP
BOP-HV
HSF
HSP
PRR
TBC
15
19
22
28
31
34
36
38
40
44
50
56
62
67
72
74
CC / VL (1)CV/CC (1)
(Autocrossover)Fast Voltage
Slew (2)CV/ CL (1)PageIndex
Design Group
UN
IPO
LAR
BIPO
LAR
SPEC
IAL
PURP
OSE
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Model ABC - Bench Style
Model ATE- DMG - Rack Mount
Model BOP - CV/CL, CC/VL
Model BOP High Power - CV/CL, CC/VL
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11352 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102Email: [email protected] • www.kepcopower.com
(1) CV/CL = Constant Voltage/Current Limit.CV/CC = Constant Voltage/Constant Current (a design referred to as Automatic Crossover).CC/VL = Constant Current/Voltage Limit.
(2) Fast voltage slewing capability makes possible true constant current operation with fast recovery.
(1) 40W models are half rack/bench style.(2) 1/4, 1/2 and 3/4 rack models are rack/bench style.(3) 1/4 and 1/2 rack models are rack/bench style.
VOLTAGE RANGE (0 to ___ ) VOLTS
BHK-MG
ABC
ATE
ATE-DMG
JQE
MAT
MPS
MSK
MST
BOP HIGH
BOP
BOP-HV
HSF
HSP
PRR
TBC
15
19
22
28
31
34
36
38
40
44
50
56
62
67
72
74
10 20 50 100 200 500 1000 2000PageIndex
Design Group
UN
IPO
LAR
BIPO
LAR
SPEC
IAL
PURP
OSE
13
A N I S O 9 0 0 1 C O M P A N Y
Model HSF - 50-350 Watt
Model MST - 200 Watt
Model BHK-MG - 0-2000V
Model HSP - 3.3~ 48V
POWER RANGE WATTS
BHK-MG
ABC
ATE
ATE-DMG
JQE
MAT
MPS
MSK
MST
BOP HIGH
BOP
BOP-HV
HSF
HSP
PRR
TBC
15
19
22
28
31
34
36
38
40
44
50
56
62
67
72
74
10 20 50 100 200 500 1000 2000PageIndex
Design Group
UN
IPO
LAR
BIPO
LAR
SPEC
IAL
PURP
OSE
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11352 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102Email: [email protected] • www.kepcopower.com