insulated in-line rectangular duct fans … / irat in-line duct fans insulated rectangular duct fan....

7
IRAB / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured from heavy gauge galvanised sheet steel. 50mm thickness of M0 glass fibre internal acoustic insulation. External rotor motor, speed controllable, IP55, Class F insulation. External wiring terminal box. Safety thermal overload protection. Working air temperature up to 60ºC. Motors Motor and impeller fitted on the inspection cover enabling easy cleaning and maintenance. Type of electrical supply Single-phase 230V 50Hz (IRAB) Three-phase 400V 50Hz (IRAT) All motors are speed by autotransformer. 400A and 400B models are speed controlable by frequency inverter. On request Three phase motors suitable for frequency inverter control with motor E22 version: 315 and 355 models. INSULATED IN-LINE RECTANGULAR DUCT FANS IRAB / IRAT Series Workshops Commercial premises Warehouses Offices A P P L I C A T I O N S Cafes, bars and restaurants Parkings Commercial and industrial kitchens Inspection door Inspection door that facilitates maintenance Technical characteristics Before making any electrical connection ensure that the voltage and frequency of the mains electrical supply matches that of the fan data plate label. * Average sound pressure level, measured at 1,5 m in free field Model Nominal ducting diameter (mm) Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current (A) Maximum airflow (m 3 /h) Sound pressure level (dB(A)) at 1,5 m* Maximum ambient temperature (ºC) Weight (kg) Speed controller Inlet Radiated IRAB/4-315 A 600 x 350 1375 500 2 3390 57 48 60 54 RMB-3,5 IRAT/4-315 A 600 x 350 1360 475 1 3450 57 48 65 52 RMT-1,5 IRAB/4-315 B 600 x 350 1260 735 2,8 4080 56 48 60 57 RMB-3,5 IRAT/4-315 B 600 x 350 1320 760 1,4 4400 58 49 60 55 RMT-1,5 IRAB/4-355 700 x 400 1300 795 3,2 4970 57 50 60 66 RMB-3,5 IRAT/4-355 700 x 400 1335 745 1,5 4940 58 51 60 64 RMT-2,5 IRAT/4-400A 800 x 500 1350 1100 1,9 6690 62 52 60 72 RMT-2,5 IRAT/4-400B 800 x 500 1310 2220 3,7 10200 78 69 50 75 RMT-5 IRAT/4-450 1000 x 500 1330 3745 5,8 12400 87 79 50 125 RMT-8 Versatile design Can be installed in any position

Upload: lybao

Post on 23-May-2018

237 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Insulated rectangular duct fan. Very low

profile design. Backward curved centrifugal

impeller. Casing manufactured from heavy gauge

galvanised sheet steel. 50mm thickness of

M0 glass fibre internal acoustic insulation.

External rotor motor, speed controllable, IP55,

Class F insulation. External wiring terminal box.

Safety thermal overload protection.

Working air temperature up to 60ºC.

Motors

Motor and impeller fitted on the inspection cover

enabling easy cleaning and maintenance.

Type of electrical supply

Single-phase 230V 50Hz (IRAB)

Three-phase 400V 50Hz (IRAT)

All motors are speed by autotransformer.

400A and 400B models are speed controlable

by frequency inverter.

On request

Three phase motors suitable for frequency

inverter control with motor E22 version: 315 and

355 models.

INSULATED IN-LINE RECTANGULAR DUCT FANS

IRAB / IRAT Series

Workshops Commercialpremises

Warehouses Offices

A P P L I C A T I O N S

Cafes, barsand restaurants

ParkingsCommercial and industrial

kitchens

Inspection door

Inspection door that facilitates

maintenance

Technical characteristicsBefore making any electrical connection ensure that the voltage and frequency of the mains electrical supply matches that of the fan data plate label.

* Average sound pressure level, measured at 1,5 m in free field

Model Nominal ducting

diameter

(mm)

Speed

(r.p.m.)

Maximum absorbed

power

(W)

Maximum absorbed current

(A)

Maximum airflow

(m3/h)

Sound pressure level (dB(A)) at 1,5 m*

Maximum ambient

temperature

(ºC)

Weight

(kg)

Speedcontroller

Inlet Radiated

IRAB/4-315 A 600 x 350 1375 500 2 3390 57 48 60 54 RMB-3,5

IRAT/4-315 A 600 x 350 1360 475 1 3450 57 48 65 52 RMT-1,5

IRAB/4-315 B 600 x 350 1260 735 2,8 4080 56 48 60 57 RMB-3,5

IRAT/4-315 B 600 x 350 1320 760 1,4 4400 58 49 60 55 RMT-1,5

IRAB/4-355 700 x 400 1300 795 3,2 4970 57 50 60 66 RMB-3,5

IRAT/4-355 700 x 400 1335 745 1,5 4940 58 51 60 64 RMT-2,5

IRAT/4-400A 800 x 500 1350 1100 1,9 6690 62 52 60 72 RMT-2,5

IRAT/4-400B 800 x 500 1310 2220 3,7 10200 78 69 50 75 RMT-5

IRAT/4-450 1000 x 500 1330 3745 5,8 12400 87 79 50 125 RMT-8

Versatile design

Can be installed in any position

Page 2: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Dimensions (mm)

IRAB-IRAT/4 315A - IRAB-IRAT/4 315B

IRAB-IRAT/4 355

IRAB-IRAT/4 400A - IRAB-IRAT/4 400B

IRAT/4 450

Page 3: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Model IRAB/4 63 125 250 500 1000 2000 4000 8000

A 55 66 72 63 64 64 61 55

Inlet B 53 64 69 59 60 59 56 51

C 53 61 63 55 55 54 49 44

A 51 68 78 81 80 78 72 66

315A Outlet B 48 65 75 77 76 73 67 60

C 48 62 71 72 70 68 60 53

A 55 56 63 50 52 52 50 40

Radiated B 53 54 60 46 48 47 45 36

C 53 51 54 42 43 42 38 29

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 55 66 72 63 64 64 61 55

Inlet B 53 64 69 59 60 59 56 51

C 53 61 63 55 55 54 49 44

A 51 68 78 81 80 78 72 66

315A Outlet B 48 65 75 77 76 73 67 60

C 48 62 71 72 70 68 60 53

A 55 56 63 50 52 52 50 40

Radiated B 53 54 60 46 48 47 45 36

C 53 51 54 42 43 42 38 29

Model IRAB/4 63 125 250 500 1000 2000 4000 8000

A 57 67 70 67 65 65 61 58

Inlet B 56 64 67 63 60 60 56 51

C 59 65 62 60 57 56 51 47

A 54 71 78 82 82 79 74 68

315B Outlet B 53 67 75 78 77 74 69 61

C 54 65 70 74 74 71 65 58

A 55 58 60 60 56 52 48 44

Radiated B 54 55 57 56 51 47 43 37

C 57 56 52 53 48 43 38 33

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 58 68 72 69 66 66 62 59

Inlet B 57 65 68 64 61 61 57 52

C 60 65 63 60 57 57 52 47

A 56 73 80 84 84 81 76 70

315B Outlet B 54 68 76 79 78 75 70 62

C 54 66 71 74 74 71 65 58

A 56 59 62 62 57 53 49 45

Radiated B 55 56 58 57 52 48 44 38

C 58 56 53 53 48 44 39 33

Model IRAB/4 63 125 250 500 1000 2000 4000 8000

A 58 74 68 69 64 65 61 54

Inlet B 53 68 63 65 59 60 57 48

C 51 65 60 62 58 58 53 49

A 56 79 81 82 81 76 71 63

355 Outlet B 53 75 77 79 76 71 65 57

C 51 70 71 74 73 69 64 58

A 56 68 62 59 56 51 46 38

Radiated B 51 62 57 55 51 46 42 32

C 49 59 54 52 50 44 38 33

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 59 75 69 70 65 66 62 55

Inlet B 54 69 64 66 60 61 58 49

C 52 66 61 63 59 59 54 50

A 57 80 82 83 82 77 72 64

355 Outlet B 54 76 78 80 77 72 66 58

C 52 71 72 75 74 70 65 59

A 57 69 63 60 57 52 47 39

Radiated B 52 63 58 56 52 47 43 33

C 50 60 55 53 51 45 39 34

Acoustic characteristics

Sound power spectrum in dB(A), at the fan inlet / outlet , and outside the fan casing (radiated noise) at 3 working points of the performance curve (A = 0 Pa) maximum supply voltage

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 62 76 70 74 68 66 65 59

Inlet B 61 72 67 72 64 61 59 54

C 58 68 62 67 61 59 55 51

A 62 83 85 86 84 80 77 67

400A Outlet B 59 78 82 83 81 76 70 63

C 61 73 78 78 76 71 65 60

A 55 68 60 59 56 54 52 44

Radiated B 54 64 57 57 52 49 46 39

C 51 60 52 52 49 47 42 36

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 66 73 73 78 76 74 67 61

Inlet B 61 69 68 75 71 68 62 55

C 61 67 64 69 67 66 61 57

A 65 77 89 91 91 87 81 73

400B Outlet B 62 74 85 87 86 82 75 68

C 61 70 80 81 81 77 71 65

A 58 66 65 65 67 67 61 55

Radiated B 53 62 60 62 62 61 56 49

C 53 60 56 56 58 59 55 51

Model IRAT/4 63 125 250 500 1000 2000 4000 8000

A 68 78 80 83 82 84 80 83

Inlet B 64 77 76 80 78 77 78 79

C 63 73 73 77 76 75 77 80

A 69 80 94 95 96 92 85 78

450 Outlet B 67 78 91 92 93 88 81 74

C 67 77 87 88 89 85 79 73

A 64 70 75 75 73 74 73 74

Radiated B 60 69 71 72 69 67 71 70

C 59 65 68 69 67 65 70 71

Page 4: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Performance curves

– Q = Air volume in, m3/hr and m3/s. – Ps = Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.

Pa

500

450

400

350

300

250

200

150

100

50

0

230V

52

48

41 51

57

44

45 58 60

170V140V115V

230V

115V

W

1000

900

800

700

600

500

400

300

200

100

00 500 1000 1500 2000 2500 3000 3500 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

IRAB/4-315A50

45

40

35

30

25

20

15

10

5

0

mmWG

Pa

500

450

400

350

300

250

200

150

100

50

0

300V

52

49

44 54

57

47

50 56 60

250V200V160V

400V

160V

W

1000

900

800

700

600

500

400

300

200

100

00 500 1000 1500 2000 2500 3000 3500 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

50

45

40

35

30

25

20

15

10

5

0

mmWG

400V

IRAT/4-315APa

500

450

400

350

300

250

200

150

100

50

0

230V

52

48

41 51

57

44

45 58 60

170V140V115V

230V

115V

W

1000

900

800

700

600

500

400

300

200

100

00 500 1000 1500 2000 2500 3000 3500 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

IRAB/4-315A50

45

40

35

30

25

20

15

10

5

0

mmWG

Pa

500

450

400

350

300

250

200

150

100

50

0

300V

52

49

44 54

57

47

50 56 60

250V200V160V

400V

160V

W

1000

900

800

700

600

500

400

300

200

100

00 500 1000 1500 2000 2500 3000 3500 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

50

45

40

35

30

25

20

15

10

5

0

mmWG

400V

IRAT/4-315A

Pa

600

500

400

300

200

100

0

230V

54

38

41

51

56

4940

52 60

170V140V115V

230V

115V

W

1200

1000

800

600

400

200

00 1000 2000 3000 4000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

60

50

40

30

20

10

0

mmWG IRAB/4-315B

Pa

600

500

400

300

200

100

0

400V

55

47

50

52

58

5446

58 62

250V200V160V

400V

160V

W

1200

1000

800

600

400

200

00 1000 2000 3000 4000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2

60

50

40

30

20

10

0

mmWG

300V

IRAT/4-315B

Pa

600

500

400

300

200

100

0

230V

54

38

41

51

56

4940

52 60

170V140V115V

230V

115V

W

1200

1000

800

600

400

200

00 1000 2000 3000 4000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0

60

50

40

30

20

10

0

mmWG IRAB/4-315B

Pa

600

500

400

300

200

100

0

400V

55

47

50

52

58

5446

58 62

250V200V160V

400V

160V

W

1200

1000

800

600

400

200

00 1000 2000 3000 4000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2

60

50

40

30

20

10

0

mmWG

300V

IRAT/4-315B

Pa

700

600

500

400

300

200

100

0

230V

55

38

48

4557

47

4055 63

170V

140V

115V

230V

115V

W

1400

1200

1000

800

600

400

200

00 1000 2000 3000 4000 5000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4

70

60

50

40

30

20

10

0

mmWG IRAB/4-355

Pa

700

600

500

400

300

200

100

0

400V

55

51

53

44

57

47

54

60 63

300V

250V

160V

400V

160V

W

1400

1200

1000

800

600

400

200

00 1000 2000 3000 4000 5000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4

70

60

50

40

30

20

10

0

mmWG

200V

IRAT/4-355

Pa

700

600

500

400

300

200

100

0

230V

55

38

48

4557

47

4055 63

170V

140V

115V

230V

115V

W

1400

1200

1000

800

600

400

200

00 1000 2000 3000 4000 5000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4

70

60

50

40

30

20

10

0

mmWG IRAB/4-355

Pa

700

600

500

400

300

200

100

0

400V

55

51

53

44

57

47

54

60 63

300V

250V

160V

400V

160V

W

1400

1200

1000

800

600

400

200

00 1000 2000 3000 4000 5000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4

70

60

50

40

30

20

10

0

mmWG

200V

IRAT/4-355

Ps Ps

PsPs

Ps Ps

Q Q

Q

QQ

Q

Page 5: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Performance curves

– Q = Air volume in, m3/hr and m3/s. – Ps = Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.

Pa

800

700

600

500

400

300

200

100

0

400V

58

52

48

54

6259

6557 63

300V250V

200V

400V

160V

W

2400

2100

1800

1500

1200

900

600

300

00 1000 2000 3000 4000 5000 6000 m3/h

m3/s0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8

80

70

60

50

40

30

20

10

0

mmWG

160V

IRAT/4-400A

0 2000 4000 6000 8000 10000m3/h0

100

200

300

400

500

600

700

800

900

Pa

0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 m3/s

0

500

1000

1500

2000

2500

3000

3500

4000

WIRAT/4-400B

400V

160V

686355

64

60

53

60

57

53

400V300V

250V200V

160V

0

10

20

30

40

50

60

70

80

90

mmcda

0 2000 4000 6000 8000 10000 12000 m3/h0

100

200

300

400

500

600

700

800

900

1000

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 m3/s

0

1500

3000

4500

6000

7500WIRAT/4-450

400V

160V

767264

72

68

61

70

67

61

400V300V

250V

200V

160V

Pa mmcda

0

10

20

30

40

50

60

70

80

90

100

Pa mmWG

Pa mmWG

Ps Ps

Ps

Q

Q Q

Page 6: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Mounting accessories

Table of Accessories

IFL-FIn-line duct bag filter

IBEElectric HeaterBattery

IBRRectangular ductFlange

IAERectangular flexibleConnector

DEFRectangular defense Guard

IBWHot water coil

IFL-G4In-line duct bag filter

ISAAnti-vibrationMounting

(1 ISA = 4 supports)

IAAAcoustic Attenuator

Model Anti-vibrationmount

Ductflange

Flexibleconnector

Soundattenuator

Defense guard

Damper Filtration box G4

IRAT-315 ISA IBR-315 IAE-315 IAA-315 DEF-600x350 IJK-315 IFL-315 G4

IRAT-355 ISA IBR-355 IAE-355 IAA-355 DEF-700x400 IJK-355 IFL-355 G4

IRAT-400 ISA IBR-400 IAE-400 IAA-400 DEF-800x500 IJK-400 IFL-400 G4

IRAT-450 ISA IBR-450 IAE-450 IAA-450 DEF-1000x500 IJK-450 IFL-450 G4

Model Filtration*box for F5,F6, F7 or F8 filters

Filter F5 Filter F6 Filter F7 Filter F8 Electric heaterbattery

Water coil

IRAT-315 IFL-315 F IFR-315 F5 IFR-315 F6 IFR-315 F7 IFR-315 F8 IBE-315/30T IBW-315

IRAT-355 IFL-355 F IFR-355 F5 IFR-355 F6 IFR-355 F7 IFR-355 F8 IBE-355/30T IBW-355

IRAT-400 IFL-400 F IFR-400 F5 IFR-400 F6 IFR-400 F7 IFR-400 F8 IBE-400/30T IBW-400

IRAT-450 IFL-450 F IFR-450 F5 IFR-450 F6 IFR-450 F7 IFR-450 F8 IBE-450/30T IBW-450

For more information see the mounting accessories for direct air fans, behind ILT serie.

Page 7: INSULATED IN-LINE RECTANGULAR DUCT FANS … / IRAT In-Line duct fans Insulated rectangular duct fan. Very low profile design. Backward curved centrifugal impeller. Casing manufactured

IRA

B /

IR

AT

In-L

ine

duc

t fa

ns

Electrical accessories

For more information see ELECTRICAL ACCESSORIES.

TTC-2000TTC-2000 + TTS-1Three phase electrical heater battery controller.The TTC-2000 needs an external temperature sensor to control the battery (TG-K300 or TG-R530)

TTC-40F + TTS-4Three phase electrical heater battery controller.The TTC-40F needs anexternal temperature sensor to control the battery (TG-K300or TG-R530)

LM-230AElectrical damper actuator

TG-K330Duct temperaturesensor

TG-R530Room temperaturesensor

DPS 2-30DPS 10-100Differential pressureswitches:- DPS 2-30: from 20Pa to 300Pa- DPS 10-100: from 100Pa to 1000Pa

RMBRMTFan speedControllers

VFTM IP21Adjustable frequencydrive for three phasemotors