Page 1: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

Integrated Motor PumpMP15, MP22, MP45, MP75 & MP9215 kW, 20 hp to 92 kW, 125 hp

Service Data Vickers®

Pumps

Page 2: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

2

Introduction

The Vickers Integrated Motor Pump is aunique combination of a conventionalAC induction motor cooled with systemhydraulic oil and a Vickers hydraulicpump, either fixed vane pump orvariable piston type, housed in a specialsound reduction enclosure.

This combination provides anexceptionally quiet and small pumpingpackage for any industrial applicationrequiring up to 125 horsepower (92kilowatts) of continuous hydraulic power.

The package comes completelyassembled, tested, and ready forinstallation.

Circulating the hydraulic oil through themotor, bathing both the rotor and stator,makes it possible to obtain twice thenormal continuous output power fromthe motor windings. As a result, physicalsize reductions of 35% to 50%compared with conventional pumpingpackages are possible. Normaloperation of the motor is not affected bycirculating oil through it, nor is thesystem’s hydraulic oil damaged.

Heat generated within the electric motoris carried away by the hydraulic fluid anddissipated by the hydraulic coolingsystem. A motor fan is not needed,which makes it practical to cover theentire assembly (motor and pump) witha compact, polyethylene soundreduction enclosure. This reduces thesound from the pump as well as themotor, resulting in a noise levelreduction that is unsurpassed in theindustry.

A complete line of standard Vickerspumps can be fitted to the IntegratedMotor Pump including single fixed vanepumps, single variable piston pumps,double vane pumps, double pistonpumps or mixed vane and pistoncombinations.

Page 3: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

3

Model Code

Second Pump Code (if required)

NOTE: Second pump code must bepreceded by a slash ( / ). Example: P57C / V45N; or P57C/P57C

Outlet Position (viewed from electric motor end)

A� - 12 o’clockB - 3 o’clockC - 9 o’clockNote: On piston pump units the case drain willalways be at the 12 o’clock position.

Main Port Connections

F1� - 4-bolt flange port, ISO 6162-Type 1 (inch)

F2 - 4-bolt flange port, ISO 6162-Type 2 (metric)

Design Number

Subject to change. Installationdimensions unaltered for designnumbers 20 through 29 inclusive.

Special Feature Suffix

S5 - Non-flooded inletS22 - Wye (start) / Delta (run) motor

winding** - Contact Vickers representative

for further information regarding S**

3 4 5 876 9 101 2 11 12

1

2

Model Series

MP - Integrated Motor Pump

Motor Power (sizes)

15 - 15 kW, 20 hp22 - 22 kW, 30 hp45 - 45 kW, 60 hp75 - 75 kW, 100 hp92 - 92 kW, 125 hp

Voltage

A� - 230V 60 HzB� - 460V 60 HzC - 575V 60 HzD - 380V 50 Hz E - 380V 60 HzF - 400V 50HzG - 220V 60HzH - 500V 50Hz

Winding Type

1 - Standard

Terminal Box Position(viewed from motor end)

R� - Right sideL - Left side

Hydraulic Pump Type

P - Variable pistonV - Vane

3

4

5

7

8

11

9

10

12

Pump Displacement (cm3/rev)

Piston:20, 32, 40, 45, 57, 74, 98, 131

Single vane:18, 27, 36, 40, 45, 55, 67, 81, 97, 112, 121, 138, 162, 193

Double vane - shaft end:40, 45, 55, 67, 81, 97, 112, 121, 138, 162

Double vane - cover end:18, 27, 36, 40, 45, 55, 67

Example: P20V40V4018

NOTE: When ordering double vane pump,designate shaft and cover end displacements.

Pump Control Type

N - No control (vane pump only)Piston pumps with cm3/rev displacementsof 20, 32, 40, 45:C - Pressure compensator (20, 40 cm3/rev) -Range is 25-210 bar (350-3000 psi), standardfactory setting is 210 bar (3000 psi).C - Pressure compensator (32, 45 cm3/rev) -Range is 25-138 bar (350-2000 psi), standardfactory setting is 138 bar (2000 psi).CM - Pressure compensator range is 25-70bar (350-1000 psi), standard factory setting is70 bar (1000 psi).CV - Pressure compensator with load sensing(20, 40 cm3/rev) - Range is 25-210 bar(350-3000 psi), standard factory setting is 210bar (3000 psi).CV - Pressure compensator with load sensing(32, 45 cm3/rev) - Range is 25-138 bar(350-2000 psi), standard factory setting is 140bar (2000 psi).Piston pumps with cm3/rev displacementsof 57, 74, 98, 131:C - Pressure compensator (20, 40 cm3/rev) -Range is 70-250 bar (1000-3600 psi), standardfactory setting is 250 bar (3600 psi).CM - Pressure compensator range is 40-70bar (580-1000 psi), standard factory setting is70 bar (1000 psi).CV - Pressure compensator with loadsensing, range is 70-280 bar (1000-4060 psi),standard factory setting is 250 bar (3600 psi).� Preferred option

� Only available on MP15 & MP22 models.

6

13

13

Page 4: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

4

15 & 22 kW Electric Motor

Housing & Stator S/A

MP15 MP22Standard Winding

230VAC-60Hz930551460VAC-60Hz930551575VAC-50Hz3001671380VAC-50Hz3001723

230VAC-60Hz930544460VAC-60Hz930544

380VAC-50Hz3001731

400VAC-50Hz3001909

Rotor, Shaft & Key S/A

MP15 MP22

230VAC-60Hz930555460VAC-60Hz930555575VAC-60Hz931023380VAC-50Hz3001765

230VAC-60Hz930548460VAC-60Hz930548575VAC-60Hz931024

End Bell Inlet930530 Flooded932234 Non-Flooded 930531 End Bell “B” face

30112 Bearing (2 req’d)

924561 Eye Bolt924577 Eye Bolt Spacer

930999 o-ring (2 req’d)

930678 Wave Washer

930532 Mounting Foot (2 req’d)

Standard Winding

575VAC-50Hz930895

Wye Delta Winding

400VAC-50Hz3019138

380VAC-50Hz3001766

400VAC-50Hz3001907

Wye Delta Winding400VAC-50Hz3019139

473427 Screw (16 req’d)torque to 25-30 Nm (18 - 22 lb. ft.)

400VAC-50Hz3019504

400VAC-50Hz3019307

400VAC-50Hz3019505

400VAC-50Hz3019308

460VAC-60Hz3019648

460VAC-60Hz3019642

380VAC-50Hz3019220

220VAC-60Hz3019547380VAC-60Hz3019458

460VAC-60Hz3019649

460VAC-60Hz3019643

380VAC-50Hz3019221

220VAC-60Hz3019548380VAC-60Hz3019459

930682 Washer (4 req’d)

473429 Screw (4 req’d)torque to 2,4-2,9 Nm (1.7 - 2.1 lb. ft.)

930680 Dampening Washer (4 req’d)

930681 Dampening Sleeve (4 req’d) 3/8”

930679 Dampening Spacer (4 req’d)

Page 5: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

5

15 & 22 kW Electric Motor

ÇÇ

473401 Screw (4 req’d) torque 10-12 Nm (7 - 9 lb. ft.)

Electrical Feedthru

MP15 MP22Standard Winding

230VAC-60Hz930662

460VAC-60Hz930661

575VAC-60Hz930661380VAC-50Hz930662

Wye Delta Winding

400VAC-50Hz3001904

230VAC-60Hz929395

460VAC-60Hz930662

575VAC-60Hz930661380VAC-50Hz930662

400VAC-50Hz3001904

930694 Shrink Tube

296758 o-ring

474270 Screw (4 req’d)torque 24.5-30.5 Nm (19 - 22 lb. ft.)

930665 Adapter

262412 o-ring

380VAC-60Hz3001904

380VAC-50Hz3001904

460VAC-60Hz3001904

ÇÇ

3001902 Metric inserts (8 if req’d)

400VAC-50Hz930662

400VAC-50Hz930662

460VAC-60Hz3001904

220VAC-60Hz3001905

931009 Tie Strap (6 req’d)

MP 15/22 Non-Flooded Inlet End Bell

932234 Non-Flooded Inlet Bell

473403 Screw (4 req’d)torque 10-12 Nm (7-9 lb.ft.)

932233 Cover Plate

262418 O-ring

Page 6: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

6

15 & 22 kW Integrated Motor Pump - Single Pump

930786 Single shroud930833 Double shroud 929400 Sound Absorbing

Material

932106 3/4” Sound Absorbing Material

External OutletsSee Table Below

Case Drain

**263497 o-ring

**924581 Grommet

**924585 Cap

**924578 Long Connector

930521 Screw (6 req’d) 929390 Cushion Strip

930620 2.5” Clamp FlangeAX214709 Bolts (4 req’d) torque 85-103 Nm(63-76 lb. ft.)Note: Use with allPVH & 35V pumps

3001651 B-C AdapterKit (if req’d)

Motor OutletsCouplingsHosePump InletsPump ClampsBoltsO-ringsSee Table Below

473474 Pump Mtg. Bolts (2 req’d for “B” face,vane or piston – 4 req’d for “C” face pistonpump) torque to 85-103 Nm (63-76 lb. ft .)

473500 Pump Mtg. Bolts (2 req’d for “C” facevane pumps) torque to 210-256 Nm (155-189 lb. ft.)

Pump Type Outlet Position Part #PVQ20 & 32 12 o’clock 930644

3 o’clock 9306459 o’clock 930643

PVQ40 & 45 12 o’clock 9306483 & 9 o’clock 930647

PVH57 12 o’clock 9306323 & 9 o’clock 930631

PVH74 12 o’clock 9306363 & 9 o’clock 930635

PVH98 12 o’clock 9306403 & 9 o’clock 930639

Load Sense Line3001956 PVQ3001848 PVH573001846 PVH743001845 PVH98

3001856 Remote compensator line(for all PVQ’s)3001859 Remote compensator line(for all PVH’s)3019063 IC tapping plate kit for PVH

Pump mtg. o-rings401525 “B” face353264 “C” face

** 2 req’d, 1 req’d for non-flooded inlet.

PumpType

ExtensionOutlet

O-ring Bolts InletPump

O-ring Bolts FlangeClamp

Outlet Motorto Pump

O-ring SplinedCoupling

Hose (cutto length)I.D. (in.)

Part Number

Clamps(2 req’d)

PVQ20/32 930626 396107 N/A 930778 396107 N/A N/A 930780 263502 584924 1.25” 930804 931004

PVQ40/45 930627 396105 N/A 930777 262502 N/A N/A 930779 263502 584924 1.50” 930805 930870

PVH57 924554 262398 AX-1074 930621 262407 AX-199740 930622 930653 262411 877040 2.00” 930806 924582

PVH74 924554 262398 AX-1074 930621 262407 AX-199740 930622 930653 262411 877040 2.00” 930806 924582

PVH98 924554 262398 AX-1074 930619 262411 AX-214709 930620 930653 262411 877040 2.00” 930806 924582

20V 930887 262393 AX-1074 930781 263502262404

N/A 930779 263502 584924 1.50” 930805 930870

25V 924554 262398 AX-1074 930781 262404263502

N/A 930779 263502 584924 1.50” 930805 930870

35V 929384 262401 298150 930621 262407 AX-199740 930622 930653 262411 877040 2.00” 930806 924582

Page 7: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

7

15 & 22 kW Integrated Motor Pump

388122 LargeThreaded Plug263504 o-ring

400221 SmallThreaded Plug263502 o-ring

929386 Access Cover930441 Cable929370 Screw (5 req’d)

930669 Outlet Port Tag

929370 Screws

930443 Label Screws

930668 Case Drain Tag

930821 Screws(28 req’d)

930671 Lift Caution Tag

930666 Air Bleed Tag930443 Screw

930672 Inlet Port Tag930443 Screw

930667 Drain Port Tag930443 Screw

930670 Caution Tag930443 Screw

930549 Conduit Box930685 Gasket

930674 Hydraulic Nameplate930709 Overlaminate930710 Backing930443 Screw

930673 Electrical Nameplate930709 Overlaminate930710 Backing930443 Screw

929376 Plug (4 req’d)

930939 Blocking plate262411 o-ring

929379 Grommet

931021 Neoprene

Inlet End Pump End

Page 8: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

8

45 kW Electric Motor

Stator Housing

MP45

Standard Winding

230VAC-60Hz3019034460VAC-60Hz930478

575VAC-50Hz930834380VAC-50Hz3001733

230VAC-60Hz3019035460VAC-60Hz924558

380VAC-50Hz931043

380VAC-60Hz3019513400VAC-50Hz3001911

End Bell Inlet932232 Non-flooded930664 Flooded 924543 End Bell

“C” Face

49759 Bearing (2 req’d)

924561 Eye Bolt924577 Eye Bolt Spacer

929371 o-ring (2 req’d)

924567 Wave Washer

473477 Screw (4 req’d)torque 85 -103 Nm (63 - 76 lb. ft.)

924583 Dampening Spacer (8 req’d)471032 Washer (4 req’d)

930474 Mounting Foot (2 req’d)

473474 Screw (12 req’d)torque 85-103 Nm(63-76 lb.ft.)

575VAC-50Hz931025

Wye Delta Winding

380VAC-50Hz3001931400VAC-50Hz3001913

380VAC-60Hz3001747

380VAC-60Hz3001764

Rotor471989 Nut (4 req’d)torque 13 -16 Nm (9.5 - 12 lb. ft.)

220VAC-60Hz3001970

220VAC-60Hz3001971

208VAC-60Hz3019278

208VAC-60Hz3019279

400VAC-50Hz3019409

400VAC-50Hz3019410

230VAC-50Hz3019624

230VAC-50Hz3019623

380VAC-50Hz3001929

380VAC-60Hz3019512

575VAC-60Hz3001560

575VAC-60Hz3001559

500VAC-50Hz3019197

500VAC-50Hz3019196

Page 9: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

9

45 kW Electric Motor

473401 Screw (4 req’d) torque 10-12 Nm (7.4 - 8.9 lb. ft.)

Electrical Feedthru

MP45

Standard Winding

230VAC-60Hz930923460VAC-60Hz929395575VAC-60Hz929395

Wye Delta Winding

930695 Shrink Tube

262412 o-ring

296758 o-ring

474270 Screw (4 req’d)torque 24,5-30,5 Nm (18 - 22 lb. ft.)

930665 Adapter

380VAC-50Hz3001905400VAC-50Hz3001905

3001902 Metric inserts (8 if req’d)

208VAC-60Hz930923220VAC-60Hz930923

400VAC-50Hz930924

230VAC-50Hz3001686

380VAC-60Hz3001905

500VAC-50Hz3001905

575VAC-60Hz3001905

ÇÇ

ÇÇ

931009 Tie Strap (6 req’d)

MP45 Non-Flooded Inlet End Bell

932232 Non-Flooded Inlet Bell

473403 Screw (4 req’d)torque 10-12 Nm (7-9 lb.ft.)

932233 Cover Plate

262418 O-ring

Page 10: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

10

45 kW Integrated Motor Pump - Single Pump

930518 Short Enclosure930519 Long Enclosure(Note: Cut long pump shroudfor PVH74 & 98)

External OutletsO-ring, BoltsSee Table Below

Case Drain

**924578 o-ring

**924581 Grommet

**924585 Cap

**924578 Long Connector

930673 Electrical Nameplate930709 Overlaminate930710 Backing930443 Screw

930521 Screw (6 req’d)

930674 Hydraulic Nameplate930709 Overlaminate930710 Backing930443 Screw

929390 Cushion Strip 353264 o-ring“C” face

End Bell OutletsHoseT-Bolt ClampsPump InletFlange ClampsBoltsO-ringsSee Table Below

Remote Compensator Line:3001859 for PVH57, 74, 983019065 for PVH1313019063 IC Tapping plate kit for all PVH’s

929400 Sound Absorbing Material

Pump Type Outlet Position Part #PVH57 12 o’clock 939632 3001848

3 & 9 o’clock 930631PVH74 12 o’clock 930636 3001846

3 & 9 o’clock 930635PVH98 12 o’clock 930640 3001845

3 & 9 o’clock 930639PVH131 12 o’clock 930947

3 o’clock 9322179 o’clock 932218

Load Sense Control

3001628 C-BAdapter kit (if req’d)

473474 Pump Mtg.boltstorque 83 - 103Nm (61 - 76 lb. ft.) (4 req’d) for “C”face piston pump 473500 Pump Mtg.bolts torque 210 - 256Nm (155 - 189 lb.ft.) (2 req’d) for “C”face vane pump

3001842

** 2 req’d, 1 req’d for non-flooded inlet.

Pump Type ExtensionOutlet

O-ring Bolts InletPump

O-ring Bolts FlangeClamp

Outlet Motorto Pump

O-ring Hose HoseClamp(2 req’d)

SplinedCoupling

PVH57 924554 262398 AX-1074 930621 262407 AX-199740 930622 924562 263504 930806 924582 877045

PVH74 924554 262398 AX-1074 930621 262407 AX-199740 930622 924562 263504 930806 924582 877045

PVH98 924554 262398 AX-1074 930619 262411 AX-214709 930620 924562 263504 930806 924582 877045

35V 929384 262401 298150 3019111 262407 AX-199740 930622 924562 263504 930906 924582 877045

45V* 930945 262404 AX-10955 930730930777 (2)930782

262416263502 (2)263504

AX-298171 N/A 930782 (3) 263504(3)

930805(3)

930870(6 req’d)

3019095

PVH131* 930946 262401 AX-10955 930957 262411 AX-214709 930620 932107 263504 930807 930933 877046

* See expanded shroud parts for mounting a PVH131 or 45V on a MP45 electric motor.

Page 11: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

11

45 kW Integrated Motor Pump

929386 Access Cover930441 Cable929370 Screw (5 req’d)

930669 Outlet Port Tag

929370 Screws

930443 Label Screws

930668 Case Drain Tag

930821 Screws(28 req’d)

929376 Plug (4 req’d)

930671 Lift Caution Tag 930475 Conduit Box

930657 Isolation Gasket

930666 Air Bleed Tag930443 Screw

930672 Inlet Port Tag930443 Screw

930667 Drain Port Tag930443 Screw

930670 Caution Tag930443 Screw

931021 Neoprene

388122 Large thd. plug263504 o-ring

929379 Grommet

Inlet End Pump End

Page 12: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

12

45 kW Integrated Motor Pump Expanded Shroud

For Mounting a PVH131 or 45V with a MP45 Electric Motor

932240 End Cover Adapter932239 End Cover

3001876 Backing Plate (16 req’d)

471014 Nut (8 req’d)

474271 Screw (8 req’d)

470712 Washer (8 req’d)

932242 Riser (qty. 4)

474272 Screw (qty. 2 per riser) torque 24,5-30,5 Nm (18-22 lb.ft.)

MP75/92 Pump End Enclosure3001645 Short3001646 Long

Page 13: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

13

75 & 92 kW Electric Motor

Stator Housing

MP75 MP92Standard Winding

460VAC-60Hz3001621

575VAC-60Hz3001678

380VAC-50Hz3001735

220VAC-60Hz3001975

Wye Delta Winding

460VAC-60Hz3001634

575VAC-60Hz3001679

460VAC-60Hz3001690

380VAC-50Hz3001888

400VAC-50Hz3019045

Rotor

MP75 MP92

460VAC-60Hz3001620

575VAC-60Hz931026

380VAC-50Hz3001767

220VAC-60Hz3001976

460VAC-60Hz3001635

575VAC-60Hz931027

380VAC-50Hz3001768

460VAC-60Hz3001809

380VAC-50Hz3001889

End Bell Inlet:930908 flooded931087 non-flooded

930910 End Bell(Note: IMP assembly number ormodel code MUST BE SUPPLIEDin order to machine the correct inletpad(s) & pump mounting holes.

930913 Bearing (2 req’d)

924561 Eye Bolt (2 req’d)

930914 Wave Washer

473477 Screw (4 req’d)torque 14-16 Nm (10-12 lb.ft.)

930916 Mounting Foot (2 req’d)

Standard Winding

Wye Delta Winding

380VAC-50Hz3001737

380VAC-60Hz3019164

400VAC-50Hz3019595

380VAC-60Hz3019165

400VAC-50Hz3019596

400VAC-50Hz3019046

473474 Screw (16 req’d)torque 85-103 Nm (63-76 lb.ft.)

924577 Spacer (2 req’d)

930917 Preformed Packing (2 req’d)

471032 Washer (4 req’d)

924583 DampeningSpacer (4 req’d)

930921 Dampening Pad (4 req’d)

Page 14: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

14

75 & 92 kW Electric Motor

ÇÇÇÇ

Electrical Feedthru

MP75 MP92Standard Winding

460VAC-60Hz930924

575VAC-60Hz930924

380VAC-50Hz930923

220VAC-60Hz3001978

Wye Delta Winding

460VAC-60Hz930923

575VAC-60Hz930923

* 460VAC-60Hz3001686

**380VAC-50Hz3001895

**400VAC-50Hz3001895

930696 Shrink Tube

262412 o-ring

296758 o-ring

930665 Adapter 380VAC-50Hz930923

474270 Screw (4 req’d)torque 24,5-30,5 Nm (19 - 22 lb. ft.)

473401 Screw (4 req’d) torque 10-12 Nm (7.4 - 8.9 lb. ft.)

* 380VAC-60Hz3001686

**400VAC-50Hz3001895

931009 Tie Strap (6 req’d)

3001902 Metric Inserts (8 if req’d)

* 3001687 ** 3001982

* 589919 ** 262385

MP75/92 Non-Flooded Inlet End Bell

931087 Non-Flooded Inlet Bell

3001682 Screw (4 req’d) torque 85-103Nm (63-76 lb.ft.)

931088 Cover Plate

931089 O-ring

931090 Drain Port Plate

262411 O-ring

AX-199740 Screw (4 req’d) torque 85-103 Nm(63-76 lb.ft.)

Page 15: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

15

75 & 92 kW Integrated Motor Pump - Single Pump

3001645 Short Enclosure3001646 Long Enclosure

External OutletsO-ring, BoltsSee Table Below

Case DrainPump Type Outlet Position Part #PVH57 12 o’clock 932111

3 & 9 o’clock 932212PVH74 12 o’clock 932202

3 & 9 o’clock 932203PVH98 12 o’clock 932205

3 o’clock 9322069 o’clock 932207

PVH131 12 o’clock 9309473 o’clock 9322179 o’clock 932217

**924578 o-ring

**924581 Grommet

**924585 Cap

**924578 Long Connector

930673 Electrical Nameplate930709 Overlaminate930710 Backing930443 Screw

930521 Screw (7 req’d)

930674 Hydraulic Nameplate930709 Overlaminate930710 Backing930443 Screw

929390 Cushion Strip

End Bell OutletsHoseT-Bolt ClampsPump InletFlange ClampsBoltsO-ringsSee Table Below

3019065 Remote Compensator Line for all PVH’s3016063 IC Tapping Plate Kit for all PVH’s

3001842 Load Sense ControlLine for all PVH’s

473474 Pump Mtg. Bolts (4 req’d for “C” face piston pump) torque 83-103 Nm(61-76 lb.ft.)353264 “C” face mtg. o-ring

473500 Pump Mtg. Bolts (2 req’d for “C”face vane pump) torque 210-256 Nm(155-189 lb. ft.)

930620 2.5” Clamp FlangeAX-214709 Screw torque 85-103 Nm (63-76 lb.ft.)(Note: Use with all PVH &35V pumps)

** 2 req’d, 1 req’d for non-flooded inlet.

PumpType

Exten-sionOutlet

O-ring Bolts InletPump

O-ring Bolts FlangeClamp

Outlet Motorto Pump

O-ring HoseClamp(qty 2)

SplinedCoupling

Hose

PVH57 930949 262398 AX-1074 930962 262407 199740 930622 930960 262411 924582 930938 930806

PVH74 930949 262398 AX-1074 930961 262407 199740 930622 930960 262411 924582 930938 930806

PVH98 930949 262398 AX-1074 930941 262411 AX-214709

930620 930959 262411 930933 930938 930807

PVH131 930946 262401 AX-10955

930957 262411 AX-214709

930620 930959 262411 930933 930937 930807

35V 930944 262401 298150 930964 262407 AX-199740

930622 930963 262411 924582 930940 930806

45V 930945 262404 AX-10955

930973 262416 AX-214765

930971 930969* 262416 930972 930940 930808

* Use with 930971 clamp flange AX-214765 screw.

Page 16: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

16

75 & 92 kW Integrated Motor Pump

929386 Access Cover930441 Cable929370 Screw (5 req’d)

930669 Outlet Port Tag

929370 Screws

930443 Label Screws

930668 Case Drain Tag

930821 Screws (28 req’d)

929376 Plug (4 req’d)

930671 Lift Caution Tag930475 Conduit Box

930685 Isolation Gasket

930666 Air Bleed Tag930443 Screw

930672 Inlet Port Tag930443 Screw

930667 Drain Port Tag930443 Screw

930670 Caution Tag930443 Screw 929400 Sound

AbsorbingMaterial

Inlet End Pump End

931021 Neoprene

929379 Grommet (2 req’d)

Rewinding Procedure for allIntegrated Motor Pumps

1. Remove end bells, discard o-rings.

2. Remove rotor and wave washer.

3. Remove feed-thru and adaptor plate,discard the o-rings.

4. Remove the stator anti-rotation pinplugs, if so equipped, discard theo-rings.

5. The stator is not removed from thehousing, treat them as a unit.

6. Heat in a furnace to 600� F for 6hours, remove debris.

7. Shot blast stator with glass beads, donot use sand.

8. Clean with an air drying solvent, nowater.

9. Replace adaptor plate and feed-thruusing new o-rings, torque screws tospecification.

10. Reline stator slots with no less thanClass H insulators.

11. Use a standard rewind procedure withClass H insulation.

12. Hook up stator and feed-thru leadsfor proper operating voltage.

13. Braze leads with copper silver alloyrod (trade name Fluff copper) ifavailable.

14. No additional flux, if possible, orcrimps are used in the hook-up.

15. Clean, trim, and smooth out the joints.

Page 17: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

17

16. Use glass filled tubing for insulation,do not use tape.

17. Lace connections to the butt windingwith heat shrinking polyester ribbon.

18. High potential test voltages inaccordance with NEMA MG1-13.03Section B Induction Motors, andNEMA 1-3.01 Sections 3.01.6 and3.01.12 must be followed.

19. The stator and housing must not bedipped in varnish.

20. To insulate the stator, use a pour-thruvarnish, Dolph Corp. recommendsCC 1049. Refer to their data sheetDolphon CC 1049 Polyester Pour onResin Kit Class H, for applicationinformation.

21. Reassemble the rotor, wave washer,and end bells with new o-ring andtorque to specifications.

22. Bench test.

23. Torque specifications and hardwaremay be found in the overhaul andservice parts literature.

24. Internal cleanliness is extremelyimportant. Protect internal surfacesand rotation mechanism from debrisand airborne dirt.

Supporting LiteratureThe following literature items can beordered through your local VickersDistributor.

PVQ Piston Pumps #GB-C-2132

PVQ Service Literature:Overhaul Manual, I-3230-SPVQ20/32 I-3233-S PVQ40/45 I-3234-S

PVH Piston Pumps #GB-C-2010

PVH Service Literature:Overhaul Manual, M-2210-S PVH57 M-2206-S PVH74 M-2207-S PVH98 M-2208-SPVH131 M-2209-S

V-Series Vane Pumps #560Vane Pump Service Literature:

Overhaul Manual, I-3157-S20V I-3195-S25V I-3196-S 35V I-3197-S 45V I-3199-S 2520V I-3200-S 2525V I-3212-S 3520V I-3202-S 3525V I-3203-S4520V I-3204-S4525V I-3208-S4535V I-3209-S

Systemic Contamination Control #561

Fluid Analysis Service #588

Noise Control in Hydraulic Systems#510

Printed in U.S.A

Page 18: Integrated Motor Pump - Eatonpub/@eaton/@hyd/documents/co… · 2 Introduction The Vickers Integrated Motor Pump is a unique combination of a conventional AC induction motor cooled

© 2009 Eaton CorporationAll Rights ReservedPrinted in USADocument No. V-POPO-TS002-ESupersedes 5035.04/EN/0999/SMarch 2009

EatonFluid Power GroupHydraulics Business USA14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952-937-9800Fax: 952-294-7722www.eaton.com/hydraulics

EatonFluid Power GroupHydraulics Business EuropeRoute de la Longeraie 71110 MorgesSwitzerlandTel: +41 (0) 21 811 4600Fax: +41 (0) 21 811 4601

EatonFluid Power GroupHydraulics Business Asia Pacific 11th Floor Hong Kong New World Tower 300 Huaihai Zhong Road Shanghai 200021 China Tel: 86-21-6387-9988 Fax: 86-21-6335-3912