INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001. USNR(, Region I, 2100 Renaissance Boulevard, Suite l 00, King of Prnssia, PA 1 9406-2 71 3. RE: EVENT 52215 Inability to Retract Industrial Radiography Source This correspondence satisfies the written report requirements of 10 CFR Part 34.10 J and Part 30.06 as it applies to Integrity Testlabs Event #52215. Attached to this correspondence are the fr>llowing documents: 1. Integrity Testlabs Radiation Safety Program Form RS-17 NEAR MISS I rNCfDENT REPORT . 2. Initial Email Correspondence of the Event to HOC 3. Radiographer's, Assistant Radiographer's and Senior Radiographer's Statements A. Radiation Survey Report RS-04 5. Photographs (2) of the Hot Piping Causing the Event 6. The Weekly Safety Toolbox Topics Detailing the Event (page 2 of 3) lf there are any concerns or if additional information is required please contact this office. Sincerely, !t/df;. William Batting ASNT LEVEL III #100898 Radiation Safety Officer 258 Quigley Bl\'d New Castle, DE 19720 Tel: 302-325-2365 Fax: 302-32:'-2·167 70 I .J-lartlc Street Unit 703. Sayreville, N.1 08872 Tel: 732-851-(>890 Fax: 7J2-S51-65::>2 2.16C Old Angleton Road. Clute TX 77531 Tel: 979-26(1-9260 Fax: 979-266-993,1

Upload: others

Post on 30-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

INTEGRITY TESTLABS, LLC

September 29, 2016

Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.

USNR(, Region I, 2100 Renaissance Boulevard, Suite l 00, King of Prnssia, PA 1 9406-2 71 3.

RE: EVENT 52215 Inability to Retract Industrial Radiography Source

This correspondence satisfies the written report requirements of 10 CFR Part 34.10 J and Part 30.06 as it

applies to Integrity Testlabs Event #52215.

Attached to this correspondence are the fr>llowing documents:

1. Integrity Testlabs Radiation Safety Program Form RS-17 NEAR MISS I rNCfDENT REPORT . 2. Initial Email Correspondence of the Event to HOC 3. Radiographer's, Assistant Radiographer's and Senior Radiographer's Statements A. Radiation Survey Report RS-04 5. Photographs (2) of the Hot Piping Causing the Event 6. The Weekly Safety Toolbox Topics Detailing the Event (page 2 of 3)

lf there are any concerns or if additional information is required please contact this office.

Sincerely,

!t/df;. Ii~· William Batting

ASNT LEVEL III #100898

Radiation Safety Officer

258 Quigley Bl\'d New Castle, DE 19720 Tel: 302-325-2365 Fax: 302-32:'-2·167 70 I .J-lartlc Street Unit 703. Sayreville, N.1 08872 Tel: 732-851-(>890 Fax: 7J2-S51-65::>2

2.16C Old Angleton Road. Clute TX 77531 Tel: 979-26(1-9260 Fax: 979-266-993,1

Page 2: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

INTEGRIY TESTLABS ITL Form RS-17 R/1 09/07/06 NEAR MISS-INCmF.NT

RADIATION SAFETY PROGRAM - NEAR MISS/ INCIDENT REPORT

TIME: I DATE: Approx. ll:ISam 09/01/2016 I

LOCATION: Unit 23, Exchangers 23-4B & 4C PBF Delaware Citv Refinerv, Delaware Citv, DF:

RADIOGRAPHY CREW:

!Redacted. 1certified Radiographer ~ssistant Radiographer

NAME OF INDIVIDUAL: I Redacted. 1certificd Radiographer, and ons1te :semor Kadiographer I Supervisor EXPOSURE DEVICE: QSA Global 8808 #S1667

Time of Exptisure: Approx. 11: 1 Sam to 12:00 pm Was the source in the exposed position? Yes l6l No l J Was the source immediately retracted? Yrs D No ~

DESCRIPTION OF OCCURRENCE

NAME OF COMPANY: Integrity Testlabs, LLC

NAME OF COMPANY: Intrgrity Testlabs, LLC

IR-192 Source S/N: 32053G I Curics: 56.S

Number of Exposures: One ( 1) Estimated time individual in the radiation boundary: Not known

Estimated distance from collimator/ source stop: Approx. 39ft

The RT crew was perfom1ing wall profilcithickncss radiography on piping located between two exchangers within the operating unit of the refinery. The initial exposure time was to he one (I) minute. The crew was using the following QSA Global/Sentinel equipment at the time of the event: Exposure Device Model 880S. I-Handle Grip Control Assembly (Remote Control Drive Cable [cranks])-Extreme Condition 25H, 1-Extreme Condition Source Guide Tube with Fixed Stop, 7rt long. I-Extreme Condition Source Guide Tube Extension, 7tl long, and I -4HVL Tungsten Collimator. Just prior to exposing the source. the radiographer positioned the drive ca bk l cranks j past the end of one of the exchangers, in order to use the exchanger for additional personal shielding.

Upon completing the one minute exposure, the radiographer retracted the source from the exposed position within the collimator in the direction of the exposure device/shielded position. The source would not fully retract to the shielded position. The radiographer then exposed the source so that it was within the collimator. The radiographer proceeded towards the exposure device with survey meter and discovered that the drive cable assembly was inadvertently laid upon uninsulated piping. (This uninsulated piping was approx. 500"F.) This caused the control assembly housing to melt. (The melted condition was later determined to be approx. 4 feet from the rear of the exposure device and on the retract side of the control assembly housing that prevented the total retraction of the source into the shielded position).

The radiographer retumed to the handle grip of the control assembly, and pulled the control assembly in order to get the assembled exposure system into as straight line as practical with the thoughts that this would allow the source to be fully retracted. The radiographer attempted a second time to retract the source to its shielded position but it would not. The radiographer then exposed the source until it was fully exposed within the collimator.

The rndiographcr instrncted the assistant radiographer to expand outward the radiation perimeter to 2mR/hr or less. The radiographer then proceeded to contact the RSO via mobile phone. Alier contacting the RSO, the RSO contacted the office and explained the situation (event) to the operations manager. At the time of the event the RSO was approx. 50 miles from the refinery. The operations manager contacted the onsite supervisor.

The onsite supervisor proceeded to the unit where the event occurred and assisted the radiography crew. The supervisor checked the work area and verified the reestablished postings of the radiation perimeter. After the supervisor assessed the situation, he contacted the RSO.

The supervisor's assessment was such that the source was free to travel but the retra<.:tion process stopped shy by approx. 2-3 feet from fully shielded position. With this information. the RSO proceeded to give the supervisor step by step instruction to get the source into the shielded/safe position. The instructions included: Acquire an I 1/16" open end wrench or an adjusted wrench to remove the yellow control conduit (housing) swage fitting at the crank handle body. Then separate the conduit (housing) from the handle body enough to facilitate pulling of the control cable in the retract direction so that the source would be shielded within the exposure device. The supervisor followed these instructions and the source was fi.tlly shielded at approx.12:00pm.

The radiographic operations were suspended for the day. The radiography crew returned all equipment lo Integrity Testlabs· facility and the RSO removed this equipment from service. The RSO prefonned inspection and maintenance on the exposure device and the associated equipment. The RSO determined that only the Remote Control Drive Cable housings were damaged. This caused the event. The exposure device, guide tubes, and collimator were returned to service. After disassembly of the Remote Control Drive Cable. the housings were replaced and the drive cable was cleaned, inspected and lubricated per manufacturer's instructions. reassembled with new housings. then returned to service.

This cvcnl was avoidable in that the radiographer should haYc taken the time lo evaluate the work cnvironmclll during the setup for this exposure. In haste, the radiographer overlooked the hot piping when locating the cranks past the end of the exchanger and rlaccd the remote control cable housing on the associated hot piping. which contributed directly to this event.

Page 3: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

INTEGRIY TESTLABS ITL Form RS-17 R/l 09/07/06 NEAR MISS-INCIDENT

DESCRIPTION OF OCCURRENCE (Cont'd) No member of the public was exposed t0 ionizing radiation in excess of2mR!hr.

The radiography crew received the following exposures as recorded on their self-reading pocket dosimeters: Radiographer: l OOmR Assistant Radiographer: 20mR Senior Radiographer: 23mR

The RSO believes that these recorded pocket dosimeter exposures to the radiographic personnel are just and accurate and does not require additional investigation based upon the RSO reviews of the involved pcrsonneal dosimetry results from Landauer for the previous 7 months.

ACTION TAKEN TO CORRECT OCClJRRENCE (Use additional paper as needed} As straightforward as it may be to perform radiographic operations safely following established regulations and procedures, appraising the work environment for hazardous conditions where the radiography will he conducted must be performed.

The corrective action to prevent another occurrence such as this event is to place importance of considering the work environment for hazardous conditions when performing field radiography. As always. Integrity Testlabs procedures shall be followed including the Operating and Emergency Procedure RSP-310. In this specific case, radiography crews must adhere to: Section 13.0 - Radiographic Operations, Paragraph 13.3, in particular; Item #4 - "Protect the radiographic equipment from temperature extremes, especially source guide tubes (and drive cable housings) from heated surfaces above l 40°F; and ltem #5 - Always attempt to maintain the radiographic system in a straight line, as is practical ...

Additional Training to all radiographic personnel concerning this event and how lo prevent this type of event in the futun.: will be conducted within 30 days of this report. (Tentatively, annual refresher training is scheduled in the next two weeks.) Also. a weekly safety .toolbox topic which covered the initial report of this event during the week of 09!05i2016 to employees of Integrity Test labs \Vas performed.

Was the RSO Notified'> Yes ~No 0 By Whom? Donald Burke I Date Notified: 09/01!2016

Action taken is Satisfactory: Y cs ~ No 0 Completion Date By: l 0/14/2016 (tentative refresher training)

President's Signature: Date: 09/29/2016

Radiation Safety Office's Signature: Date: 09/2911016

, J

Page 4: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

Delaware City, DE

Equiptl1ent: QSA Global Model 880s #S 1667 w/ IR-192 #32053G - 56.SCuries 25Ft Extreme Control Cables with two extreme guide tubes, each guide tube ?ft long and the

outer most guide stop having a source stop. One - 4HVL Tungsten collimator

At l l :22am, the RSO for Integrity Testlabs, LLC, received telephone notification from the field radiographer at the clicnrs location that he was unable to retract the source fully into the shielded portion. The radiographer attempted to retract the source twice. The radiographer realized the source was not going to get shielded because he noticed that the control cable housing was laying on equipment which was later determined to be approximately 500°F. This melted the control cable housing and in turn prevented the complete retraction of the source into the shielded position. The radiographer kept the source to the fully exposed position within the 4HYL collimator, and proceeded to extended the posted radiation area boundaries to 2rnR/l1r or less, then contacted the RSO at 11 :22am. The RSO was approximately 50 miles away and stated he was on his way to assist in the recovery process. The company and RSO arc authorized to perform recovery of sources.

The radiographer then contact his su'pervisor, who was the senior radiographer onsite. The supervisor also attempted to retract the source into the shielded position. The supervisor contacted the RSO and explained the situation. By direction from the RSO via telephone communication, the supervisor was able to disconnect the controlhousing at remote control crank and pull the control cable so that the source was retracted into the shielded position. The radiography operations was tenninatcd for the day. Surveys were performed after the source was shielded with no unusual readings. All equipment was returned ITL's facility.

The following self-reading pocket dosimeter readings were recorded at the conclusion of this event. The radiographer and assistant radiographer had performed 6 exposures for the day. The 6 exposures included the event. · Radiographer I OOMR Assistant 20mR Supervisor 23mR during the recovery process No radiographic personnel or member of the pubic was overexposed <luring the entire event.

The affected equipment will be inspected, repaired or replaced, as needed.

A follow report will be submitted to Region I as soon as practical.

Regards.

BILL BATTING ASNT LEVEL llI #100898 Radiation Safoty Officer

302-325-2365 Office 302-325-2467 Fax

302-632-1624 Cell

http://www.intcgrit.Y!estlabsllc.com/

SAFETY and QUALITY in NDT

2

Page 5: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

1.) Received a phone call from our office at ITL stating the situation.

2.) Went over to the unit and signed in and walked over to the job site.

3.) Double checked the work site by surveying the area and rope boundaries, that it was safe to

proceed doser.

4.) Looked at the situation and contacted our RSO Bill Batting and told him about my findings.

5.) I was instructed to safely check the crank connections and guide tubes. I told Bill Batting that I

seen the cranks were burnt and thought that could be the hold up from cranking the source all

the way back to camera into the locked position. Structures in the area were 422-499 degrees F

6.) I was then instructed to undo the yellow side of the cable from the crank handle and pull it back

by hand.

7.) Buy doing what I was told by Bill Batting the source went back into the locked position. I

surveyed the camera and guide tubes to make sure everything was secure.

8.) After I made sure everything was secure I contacted Bill Batting and let him know the situation

was under control, and then let the client know.

Name and signature redacted.

Page 6: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

11 11 ~\ I ~ r. \J 1

\ \ . ~ ' l -·1 \,-.L

' ' ' • v-. \-., ' J .,_,.., ; ' ,"--\. ·•. _> G ' v .__, C-J V ' I V

'

J" CC: C\ bv ~ ',\'V\J.\ +.i""t<; 0\ t-"' "'"\"<;.~ <; <;'O ". w y \ ol-I --.:iw ~+ '=:~--\:· -*;·\) ''\J~""JG'--o +~-ya-.J o-\-. ~o\O"-'.re>l---f'a \J.7>\Jr\-· <. s)\\>'QJ-:J "d\.\-t

-'rY)o uc.i-f>~""-.it<; ot ?">'+ l . t\"W ot ti. ycic;"'Y.l-::J

'f:i'. \ M .1?AJJQJ Cl~t Gv: UJVJ'-\-vu'-\M ud 1cj c 005

':l

I I b\..1 OJ(\/\ <; "() M \VJ~ M

<J • .j\' J J'd-'--'J'CiJ 0~1· \:~ __ f'OMO--\-.

. f._W. \'<>~Cf'-'\;' 'J'"-\''DW '. \ \ 9J

-I --1..-J~ "d)~

1'uf\ JYj<;:

?°11 \J'QJ-;) .I. . P"'J-\-dJ A.\\~ \0 VI ?\YI 0 (VI -\"'(\ ( u JJ"'OC, "'-\ t \~'OJ1"J "'t ?'l~"C0/oJd T "r "'.W ""'"' "'"'It J"t .J'V . d.\Y\ \), w 1

-..\-!. o C) ..• rv\ c;: O d 'x 0 \J'Q \:7":)\J 1 I · 0 \ \ ~\\ ·~

0M0'-\~ ..>-a\tivJ AoA..JYJ~ l\W

<;--o . ..JOfDw: \\CJ;) <l\_\-\· ol:v ~ -\":--"lo ~ VJfV\ ()'-\+ \\~ ()J~V1Q<;

""I+ yo~ V'<) "'o I · yad \-~ a"\"\-w OJ j-bv : \?\ '1'. '-\ c;. "Jt x-a 0 '-\-\-'--\ -\;'. M

· "j[J 'l./7'rf a-;):1°.J'0~)d 0+ .JobvV:J"'\:J1'o \,l'Q ?vYlO_J"YJ S)t v'O.J'J '?>"\-1· fd\ \ YlQ

. ---·\i AD"VJo' 0-l,.. oocfOd-:) o ..Jd ! · .JobU~-JJ<O u"Y) yV'() ~j()\.A.JY,}J O'-j' · \ -.J \ \ -~-. .. \ \

v.0 \=>v'O~ \.Jo~t"O\Yl<;,v~ u-Y-J o-\-... ><u-y:--u\j.J.:\lo'J '¥,) \.\\~/"", aC\,"'+ c~~V)G

()"-\-\-· ~0 av.\'0\ J '(V'O 'dd ~a ~t v o u.-\ :s -zi"-Yr-v-~f:r·:i \a { ..

~1 , \ r"\'i,,. 'V'\ ' •• OC) u. c;. Ot. d Y) -l...<>c; T r v.-..., oM+ \Jo?M.l--v v . +~J ..,,. v 1 \ \ • S..; ;'.;\.) v'<:>'--\'J-" o \

If u-t:.\ ; ch:~ h,L.S ~h : j~?'\ti ')+ "".Jtj WJ'O'V

Page 7: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

L_ ____ ~pe...:_pe_:_p_eJ_eJ__:ni_eu----'B!___.S I '--\--VO WC> J >:i\ r!;,_) yso <;. J ~ C\-, J

" o :-\; '" ~"" : , "'J-oc;--u "'t\ o + \Y£l)\"'\ c:;,~(Y\ t v c w d ·. "'bo \ (\J yvv.::i -.1w 00\ Zl}(:).J Jo-f3w~<;:..<>~ -\-'d'j\-JQd i\w ·a \Jo)\--O~-~..Jci{"'\

<;;-;iJY)\:J ~ 6 \lVV) \JM<Jv \.,l~OJQ,_ Cl.SOM. <;o ClaJ ""\-\ yvv:i

. \ 'O rv;i; .i ~J ~~ 1 o gc; (} "'\-\ ?" ~ }'~o\J .. S-C>U,, c'9-o .J \;'o \ ~'() j

. J r.J',Uoc:;, 0'-U_ ' \JM<;)? u.-;y._/I 0..)CJ\. <;":lf'I\. 6 \) \~-\-~..Jd C\Q

Y\J-O '7\ 00\ Uj'?M <; ~C>(\ JY)c; \ \,10~',;<:.~ \'V'/\ 'Y)\ ""\-\ '

0\-\J ·' )\ :KJC\ -t \J d{v\ '2>J.JYXJS d'\_L ' \J l. -t '. \ \ 'Nj A_ \ \'<YY\ IJ'Ju_

. 'f'V ";) d wvY::>"\ '-A, \JN),) ) 0\.\.,-\ VO Cl -;Jd \ d "0 (V\d.JJ<; \JY] Ct· UJ '. \,

~flV\.,\~<;\.I : 0 <;(). "'-\-\-\ '.\-UY) A\ \'';y:; ~ d 7)Yj s VY) s.-r J'::>j -'f" ~ 3 \ dVJoJ ":> -yd~-\'.'O J ~'\ch£' a: ZoJ JO'. \..l'(G "'\-\ y;i"\ J-\ "' rv

· :r_ 'j-\ CG f\v.J '·'!'."'\-\-y-;:. 'J •. Jul\ ~""0 -\-v 1 o ~ /\\so ~ \ "C

i ( ,.., f; \Jo'-\ t --'" \'Od)\; c:i v.. on M 'f" \ 'i"" <; o : J "'? \.>V\ OG_, rruv v I.\-\-

'-\ c ~ \J '.j ~ <:: '. c. <;'<J c:,: 1 o I\ d""J Sc,~~ J <) 1u-;:r; o L\-t -T-f-" v:i-\ s, s <; v: Ai 1. C'

~ iJJ. ~6 \ O I_\ '->'d'-\-\-\ ' U \ ~"\, 0-\-'?°I' '. .J ~":) -l Cl \.\ IJ'-::>.l \) Q \ ~ ~

1J \ J ~ <;. <YJ')Y) <;VY\ <; °'0 M

'\'0-\(yVl'O\-'\"Cl ~vV) <::: 0(\"'t

~>0~-\ -S?r\J\j '-\-O'OJToj

"\' '."' \;' "'\\ \J "T"-\ S., "'J \c; o+ ?u"'J\.,\ '-1 ~ _J ~-yuw A ()(\J-.')c;. J'--\--\ '-\ -f. M 'O--J-'"?>'-li'0'J o"--\t \ \ '\0 d

ot ~~ :i-\ Vo\_\--\-:L_ . r\-v>O) ~

() VlO!V\. ~~ o\A-\ ~\0-\-or-\ , O<;() 0~-\

Page 8: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

!Name redacted.

P(J(..-/c<- Jr A- I&-• (II\. '. L re ?... 5 1 '-- / g"

, ( 'ZP 11\.{l.-- )

(:; _Si L 4f. lit> I 2-L\

I t.M-• ~h !Name redacted. , .Jcl-

)t-~ +v L ;<._ c__ /;,_ ~'--<5 Cr-- Oc"\-t;-&

ht\ ~.v-,~.!_ .J-c.. /fl.L.1 J.o CJ, i,0e_.

)hL<- lNoZ... r:!A i<:;,.lv..~ J-k ... J- I JCrf k.. CIA tk- C. r C<I\. h_ ~ ..1-t.? C·.: i,... J ·'

.5 ,"'1 .h. ) 0 J- \,veF V\ ;"\ .s. Ct'\ tk....

-k- Suvtl.-C.. bc ... c h.__ h 1-t-t...

iJu L. /..):.. k '-l( i 5 /t (

vp

·1-k.Y\

i::_c,,~

.}-kv'1

LIC+t k \.. . ·fko 11ve---e.... ulcl<- ~ 7e<-

LCt.>1--~ ..... D j..k,A bri:-,.,.k.L- ()(:.t~v~

~lr-c.,, c_ c. ~.,,,__.,, C"-J L. brovui- j ).,(;t,I,'\. +-~ roF-5> /,ve- ~ peu:.k.._ Vy?

L CJv~ oil- d-k. "- DrJa1-C-- S~\h~ ~ J..vvll k_ ~'l. s: s. .. ,)("-• ... V _ h::> ~

;f\

Signature redacted.

Page 9: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

Integrity Testlabs 2016 Weekly Safety Toolbox Topics Meeting GENERAL SAFETY TOPIC

DEHYDRATION and HOT WEATHER I know what you arc thinking ... It is getting a bit cooler and Battin:g talks about dehydration and hot weather.

The human body contains a high proportion of water. so when the temperature rises and the body tries to cool itself by sweating. dehydration can be a real concern, particularly for those of us that work in hot environment<; such as power plants and refineries.

What is dehydration? Dehydration is the loss of water and salts from the body. We need water to maintain enough blood and other fluids to function properly, and to maintain our blood pressure. Along with the fluids, the body also needs electrolytes, which are salts normally found in blood, other fluids, and cells.

How do we lose fluid? The body may lose fluids in a variety of ways: • When urinating; • When you vomit or have diarrhea; • When sweating; and • From the lungs when you breathe.

Why do we need water? The human body consists of nearly 60 percent water; brain tissue is said to consist of about 85 percent water. This is why drinking 6-8 glasses of water a day helps our body function efficiently. It is estimated that if we lost just one-tenth of the water within our body; we would not be able to stand, let alone walk.

Although fluid loss occurs during hard physical work, even simple tasks like walking can result in a significant loss of fluid within a very short period, especially in the environments where we work. We can also lose more body fluids in hot or humid conditions.

Know the Stages of Dehydration The early stages of dehydration usually have no signs or symptoms, but can include dryness of the mouth and thirst. Other symptoms in early or mild dehydration may include dry, wam1 skin; dizziness; or cramping in the arms and legs. As dehydration increases, signs may include: • A flushed face; • Rapid pulse; • Dark. yellow urine; or Passing less urine than nonnal; • Sunken eyes; • Skin that has lost iLi; elasticity and does not quickly return to its normal position after being pinched; and • Irritability or drowsiness as well as irrational behavior;

If you are with someone. who suddenly becomes dizzy, nauseated or weak during hot weather, get him or her indoors or in the shade. Replace lost fluids with cool water and cool the person down with a cool shower or sponge bath. Seek medical attention if the symptoms get worse or last for more than an hour.

If someone has dry, red skin, has a fast pulse, looks confused or delirious, or feels very hot, that person is in extreme danger and you should seek medical attention immediately, as well as taking the steps outlined above. In severe cases, dehydration can result in shock and even death.

How do I combat dehydration during hot weather? Water should be given to counteract dehydration. Drink plenty of water before you get to the stage of feeling thirsty. It is best to remember that other drinks, such as soft drinks, coffee, or alcohol-containing beverages, are no real substitute for water. Although they contain water, they also contain dehydrating agents.

So-called isotonic sports drinks can replace some of the salts lost when sweating during intense or prolonged exercise, and are an appropriate fluid replacement in this setting.

Preventing dehydration during hot weather ll is recommended that during hot weather you should be drinking water even when not thirsty. Drink at least one-and-a-half cups of water every half hour and at least one-and-a-half cups of water 20-30 minutes before working in the heat.

Other things you can do to avoid dehydration during hot weather include: • A voiding the sun in the middle of the day whenever possible, do outdoor activities early in the morning or evening instead; • Wearing sunscreen and a hat that shades your head, neck, cars and lace, sunburn stops your body from cooling itself down

properly; • Wearing thin, loose clothing as this allows good airf1ow, which helps sweat evaporate; and • 1\ voiding dnrk clothing, as this absorbs more heat than light clothing.

By recognizing the signs of dehydration and taking measures to prevent it, you can be safe and prevent dehydration.

PD-~-· l ,,.,, 3

Page 10: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

Integrity Testlabs 2016 Weekly Safety Toolbox Topics Meeting WHEN UNSAFE WORKING CONDITIONS ARE IGNORED,

OR SAFE PRACTICES ARE MINIMIZED; PEOPLE GET HURT, PEOPLE GET SICK, PEOPLE DO DIE!

INTEGRITY TESTLABS

SAFETY IS ALWAYS UP TO YOU!

RADIATION SAFETY TOPIC INABILITY TO RETRACT SOURCE

Event: The inability to retract an industrial radiography source into the shielded position Date: 09/01/2016 Time Approx. l 1:15am Location: Delaware City Refinery,

4550 Wrangle Hill Rd. Delaware City, DE

Equipment: QSA Global Model 880S #S 1667 w/ IR-192 #32053G - 56.5Curies 25Ft Extreme Control Cables with two extreme guide tubes, each guide tube 71l long and the outer most guide tube havilig a source stop. . One - 4HVL Tungsten collimator

At l l :22am, the RSO for Integrity Testlabs, LLC, received telephone notification from the field radiographer at the client's location that he was unable to retract the source folly into the shielded portion. The radiographer attempted to retract the source twice. The radiographer realized the source was not going to get shielded because he noticed that the control cable housing was laying on equipment which was later detennined to be approximately 500°F. This melted the control cable housing and in tum prevented the complete retraction of the source into the shielded position. The radiographer kept the source to the folly exposed position within the 4HVL collimator, and proceeded to extend the posted radiation area boundaries to 2mR/hr or less, then contacted the RSO at 11 :22am. The RSO was approximately 50 miles away and stated he was on his way to assist in. the recovery process. The company and RSO an;: authorized to perfonn recovery of sources. ·

The radiographer then contacted his supervisor, who was the senior radiographer onsite. The supervisor also attempted to retract the source into the shielded position. The supervisor contacted the RSO and explained the situation. By direction from the RSO via telephone communication, the supervisor was able to disconnect the control housing at the remote

. control crank and pull the control cable so that the source was retracted into the shielded position. The radiography operations were terminated for the day. Surveys were performed after the source was shielded with no unusual readings. All equipment was returned to ITL's facility.

The following self-reading pocket dosimeter readings were recorded at the conclusion of this event. The radiographer and assistant radiographer had performed 6 exposures for the day. The 6 exposures included the event. Radiographer lOOmR Assistant 20mR Supervisor 23mR during the recovery process No radiographic personnel or members of the pubic were overexposed during the entire event.

The affected equipment will be inspected, repaired or replaced, as needed.

Kudos tol land I lror recognizing the emergency and responding accordingly; their training paid off. Kudos also go out as well tol f who was instrumental in assessing the situation and relaying the information to me. With the information from all personnel involved, the source was able to be retracted into the shielded position with no overexposures. A JOB WELL DONE UNDER THE CIRCUMSTANCES!

?

REMEMBER TO VISUALLY SUPERVISOR THE RADIOGRAPHER TRAINEE/ASSISTANT

NOTIFY THE RSO IF: 1. During your daily inspections you encounter problems with the radiography equipment 2. The vehicle's securi"I' ~J•stem daily checks does not jimctio11 as iustalled 3. The n~ar door of the transport vehicle cannot be kept locked at all times (except when in use) 4. iV!tile pe1for111i11g radiography yo1111otice" c/umge in tile equipment's normal operating c/wracteristics

SAFETY HfffLINE: 302-545-%63 or RSO's mobile #302-632-1624 (CALL OR TEXT)

pa_'?t- 2. 'D~ J

' I

___J

Page 11: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

Integrity Testlabs 2016 Weekly Safctv Toolbox Topics Meeting w

Week of 09/05/16 ~ """"'·-·-"""'-·-·""'- =·~~'-"'"""" ""-'""'""' """'"' --·:: .. ;:...::;-· ':..£:~·:;; .-,.,, __ '- .... ",.,.· -- ---· -~,.-.•..

DEHYDRA TlON and HOT WEATHER INABILITY TO RETRACT SOURCE

-···· .. =-·-·'··

NAME SIGNATURE REOUIRED ~NAME SIGNATURE REOUIRED

Names of training attendees Names of training redacted. attendees redacted.

-j,

--._

-- I

-J

-l

' -I

- i

'I

=:j "·-- ---

' Toolbox Meeting Conducted n~~~leasc Print Name>.~,.,JL_ =·"'-"··-~~========~"""-"'"""""'~"""""~~=~~~ PLEASE RETURN ONLY THE SIGNED ATTENDANCE SHEET To: BILL BATTING

Email: [email protected] Fax: 302-325-2467

___J

Page 12: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

INTEGRITY T.ESTLABS TRANSPORTATION DOCUMENT

DATED: (MMIDDIYY) . OQ" I o I I I c., This document must be the top most document during transportation. This document must be laced on the driver's seat or driver's door holder when exitin

FIRST TRANSPORT FROM

FIRST TRANSPORT TO

Form RS-05 R-6 08/24/2015

RO. UN-2916, RADIOACTIVE MATERIAL. TYPE B(U) PACKAGE. CLASS 7, ffi-192, SPECIAL FORM Certificates of Com liance: 880D/S USA/9296/B 96 and SPECIAL FORM Certificate: USA/0335/S-96

880 IR-192 IR-192 SERIAL -$) ft(.; 7 SERIAL "2 J 3 ACTIVITY

NUMBER: NUMBER: .:; 05 fr Ci x 3 ·INSPEcnON OF.THE 880:& TRANSPORTILOCK:80X·PRIOR TO TRANSPORTING'. '·. ·c c:kaoxAE:rE:R,coM'Pi:E'flNG'.Ttm;INs'PEciloN'::,:~:::::.{(/ ··.• .".,· ·· .. ·.~·: .... · •. q •••••••

nspection of the 880 was Performed and is Acceptable For Transport Ins ection of the Trans rt/Lock Box was Performe Has Re uired Labels and is Acee table For Trans rt

'TJlANSJ>ORTffiOCK!BOXl&~!VEiil:dLE'StrRVEYS•.;;.g;.JU!coRirniE"BIGHEST'.CRE!ADJNGS;\·~ •' ' ,mRJhi' '' ', ', • Sv/hi' Transport/Lock Box Exterior Surface* NOTE: equal to or less than SO.OmR/hr (500 ¢Iv/hr f • () 16 ..

ITL-

RADIOGRAPHER'S SIGNATURE:

jName reda~ted.

~~~.#,~B;~.ilfe.tYQffl.~~t::~o2£§~~~!(;~4'.':'.'\:'.> ... ·>'.·c'( .. ·•·. ... . · .: -:< ::.·,\- .:: ·. · · ... · · . · · .. · (RSO may b~. contaeted. fOr ~SistancC, buf emefgciicy response for vehicle ~dents.or spills; the l~ authorities should first be contacted.)· Iil~griif.~estla~spfti~~:·J,ol,:3z.~~3~s .. -: , - · .. ·· · .,,.· :. _ · · · · · · .··· ·. · Stacey Spik¢ 1'.f~J>ile: 302-54~566~·, , , · · · _ · ' · . · · · · ·.· . . · - . · 24-Honr Elnergency:· CHEMnIBC.800-4,24-9300 (CCN70t472) ·.

" ' " ' ' , ' imitER: to' JtMERGi:Ncy ruis:Pb~sE' GtJIDE 'BOOK: ' GmriE'#163 RAD,IOACTIVE MATERIALS'

OW·TO IIlGH LEVEL RADIATIO

•,..'

··.,.

Page 13: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

lNTEGIUTY TESTLABS RADIATION SURVEY REPORT Radiation Survey Report ITL Form RS-04 R/4 10/31 /06

DATE: I <1 ··I . i ~ I CUSTOMER: I Pri l= LOCATION: Oe..\r. w ·- r L c,+y (Citv & State) OE I PAGE I of i

RADIOGRAPRER CERTIFYING AGENCY CERTIFICATION ALARMING RA TEMETERS Di\11.Y DOSIMETER RECORDINGS OSL RAlllOGRAPHlC PERSONNEL

NUMBER RAlll,XRAYor EXPIRATION

POCKETboSIJ\fETER(SRPD) (mR)

l!.XPIRATION EXPIRATION ISSUED BY: BOTH DATE:

SERIAL NUMBER SERIAL BEGINNING or END of SllIIT DATE: NUl\fBER DATE: SHIIT

~ () "1"X A"'ltJT 12.AM I -1 Ct u (1 .._....., Ll f'.l-17 ·IL ]JJ_U::i.~llf1) I ">-11' .11 u< I Oc"J

' ::l ll - - -- q 1"'1,.n "1 11-fi'·lf L~'l ·''/'.J l</. LJ-1.5-f'7 d -:J tJ

EXPOSURE DEVICE SURVEY INSTRUMENTS DAILY EOUIPMENT INSPECTION & OPERATIONAL & VEHICLE CHECKS MODEL#: I 6SOL0 880D/S l8l MANUFACTURER: NDS PRODUCTS EXPOSURE DEVJCE DAIL y INSPECTION: ACCEPT 12f REJECT D

CAMERA#: I S\/..,(, 7 MODEL NUMBER: ND-2000 EXP.DEVICEASSOCIATEDEQUIPJ'rlENTINSPECTION: ACCEPT z REJECTD

MAINT. DUE DATE: I n . \ - I ~ SERIAL NUMBER: ti q <" s:2 I SURVEY INSTRUMENT INSPECTION & CHECKS: ACCEPT I/ REJECT I I RADIOACTIVE MATERIAL CALIBRATION DATE: l-17 ~, ~ ALARJ'tUNG RATEl'rlETER INSPECTION & CHECKS: ACCEPT l;" REJECT D

ISOTOPE: JR19218] SE7S0 CALIBRATION DUE DATE: I :l ~ \ '"fv I {g POCKET DOSIMETERS INSPECTION & CHECKS: ACCEPT ~ REJECT D

SOURCE#: ~ :J.O "\~ ('_ SERIAL NU.MBER: ll"X 7- L.I ~ VEHICLE ALARM SECURITY SYSTEM CHECKS: ACCEPT l..l 11" REJECT D

ACTIVITY. CURIES: 5° ~ . '5- CALIBRATION DATE: ~ • LJ - I u COMMENTS I REMARKS ON INSPECTION & CHECKS (Red Tag ALL Rele£ted Items. Do not t---------t--~~-----+----------+-'..._~~~-__, use. Notify the RSOl:

ACTIVITY-GBq: ?OC..I .~ CALIBRATIONDUEDATE: '1-1.l -17

EXPOSURE DEVICE SURVEYS

REMOVED FROM STORAGE SURVEY ·3c 300

Record the Highest Reading mR/hr uS/hr

AFTER LAST EXPOSURE SURVEY "'3c )(rO

Record the Highest Reading mR/hr 118/br

PRIOR TO --2. FINALSTORAGESURVEY Jl ·)(.{)

Record the Highest Reading mR/br 11S/br

RADIATION AREA SURVEYS

Document the distances from the source of radiation to the Radiation Area Boundaries.

The Radiation Area Shall Be Posted So That The Radiation Intensity Does Not Exceed 2 mR In Any One Hour.

Maximum Permissible Intensity Level

#of Exposures In 1 Hr=~?..~­

Time per Exposure(mins)= 4 5

(., I Time Per I , Total Number of Exposures 4 < #of Exposures In l Hr. x Minutes Exuosure ~ m I /\. n 1-4 _..HV ____ L_C_o-:l.,..,-Jim-at_o_,r U,.--se....,d'""'~_,.i--=---'----==='-"-'---'"--'.......,,--1 Per Exposure = ..:J.Q_

Feet 2.SG mR/hr C,)..

n ~o mRJhr L. 2.. (60 + cw ) x 2 =Maximum Feet "'-...I' ·Intensity at Boundary in riiRfhr

a

Feet 25G

Feet 05"'5 mR/hrt!.. J.. Intensity Level

at Boundary mR/hr

Comments and Additional Shielding: (' Olrlc <"' -~P , ~tP o \ CERTIFYING S'Ii..TEMENT with SIGNATURE - By my signature below, I certify that:

• All radiation safety procedures and precautions required by Integrity Testlab Radiation Safety Program, including the Operating and Emergency procedure, associated Radiation Safety Procedures, the License and its' conditions, as well as applicable regulations, were observed with full compliance and maintained during all licensed activities.

• "Ihe perimeter of the storage area was surveyed prior to removal of the exposure device from storage and immediately following placement of the exposure device upon final storage. "Ihe maximum radiation intensity was not in excess of 2mRl1ir.

• After every completed exposure, the exterior of the exposure device, all attached source guide tubes, including the collimator, when used, was surveyed to insure that the source had returned to its' fully shielded position within the exposure device.

• Integrity Testlab Security Procedures were followed and the vehicle's security systems were inspected, checked and activated whenever the vehicle was left unattended that contained exposure devices. • All infonnation, statements, nnd representations documented on this form are true and correct, to the best of my knowledge. • 1 further understand that failure to comply witl1 all safety and security procedures and regulations may cause httegrity Testlab to be in violation of the NRC regulations and license conditions and will result in

disciplinary, enforcement or tennination of emnloyment actions against me by the RSO and/or INTEGRITY TESTLi\13 Management

CERTIFIED RADIOGRAPHER'S SIGNATURE: 11 I L-..~~~~~~_J-~~~~~~~-~~~~-~

Page 14: INTEGRITY TESTLABS, LLC Washington, DC 20555-0001 ... · INTEGRITY TESTLABS, LLC September 29, 2016 Director Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory

I '

Bill Batting

From: Sent: To:

Subject:

Received. Thank you.

Hoc, HOO X <[email protected]> Thursday, September 01, 2016 2:27 PM Bill Batting RE: FW: Event 52215

Headquarters Operations Officer

U.S. Nuclear Regulatory Commiss.ion

Phone: 301-816-5100 Fax: . 301-816-5151 email: [email protected]

secure email: [email protected]

From: Bill Batting [mailto:[email protected]] Sent: Thursday, September 01, 2016 2:50 PM To: Hoc, HOO X <[email protected]>

Subject: [External_Sender] FW: Event 52215

BILL BATTING ASNT LEVEL Ill # 100898 Radiation Safety Officer

302-325-2365 Office 302-325-2467 Fax

302-632-1624 Cell

http://www.integritytestlabsllc.com/

SAFETY and QUALITY in NDT

From: Bill Batting [mailto:[email protected]] Sent: Thursday, September 01, 2016 2:35 PM To: '[email protected]' Cc: [email protected] Subject: Event 52215

NRC Operations Center

Event: The inability to retract an industrial radiography source into the shielded position. Date: 09/0I12016 Time Approx. 11: l 5am Location: Delaware City Refinery,

4550 Wrangle Hill Rd.