Intel® Solid-State Drive DC S3500 Series Product Specification Capacity: 2.5-inch: 80/120/160/240/300/480/600/800 GB 1.8-inch: 80/240/400/800 GB Components: Intel ® 20nm NAND Flash Memory Multi-Level Cell (MLC) Form Factor: 2.5–inch and 1.8-inch Read and Write IOPS 1,2 (Full LBA Range, IOMeter* Queue Depth 32) Random 4KB 3 Reads: Up to 75,000 IOPS Random 4KB Writes: Up to 11,500 IOPS Random 8KB 3 Reads: Up to 47,500 IOPS Random 8KB Writes: Up to 5,500 IOPS Bandwidth Performance 1 Sustained Sequential Read: Up to 500 MB/s 4 Sustained Sequential Write: Up to 450 MB/s Latency (average sequential) Read: 50 µs (TYP) Write: 65 µs (TYP) Quality of Service 5, 6 Read/Write: 500 µs / 5 ms (99.9%) AES 256-bit Encryption Compliance SATA Revision 3.0; compatible with SATA 6Gb/s, 3Gb/s and 1.5Gb/s interface rates ATA-ATAPI command Set – 2 (ACS-2); includes SCT (Smart Command Transport) and device statistics log support Enhanced SMART ATA feature set Native Command Queuing (NCQ) command set Data set management Trim command Compatibility Windows* 7 and Windows* 8 Windows* Server 2012 Windows* Server 2008 Enterprise 32/64bit SP2 Windows* Server 2008 R2 SP1 Windows* Server 2003 Enterprise R2 64bit SP2 Red Hat* Enterprise Linux* 5.5, 5.6, 6.1, 6.3 SUSE* Linux* Enterprise Server 10, 11 SP1 CentOS* 64bit 5.7, 6.3 Intel ® SSD Toolbox with Intel ® SSD Optimizer Product Ecological Compliance RoHS* Power Management 2.5-inch: 5 V or 12 V SATA Supply Rail 7 1.8-inch: 3.3 V SATA Supply Rail SATA Interface Power Management OS-aware hot plug/removal Enhanced power-loss data protection Power 8 Active: Up to 5.0 W (TYP) Idle: 650 mW Weight 2.5-inch 80-240GB: 70 grams ± 2 grams 2.5-inch 300-800GB: 72 grams ± 2 grams 1.8-inch 80GB: 35 grams ± 2 grams 1.8-inch 240-800GB: 37 grams ± 2 grams Temperature Operating: 0° C to 70° C Non-Operating 9 : -55° C to 95° C Temperature monitoring and logging Thermal throttling Shock (operating and non-operating): 1,000 G/0.5 msec Vibration Operating: 2.17 GRMS (5-700 Hz) Non-Operating: 3.13 GRMS (5-800 Hz) Altitude 10 Operating: -1,000 to 10,000 ft Operating 11 : 10,000 to 15,000 ft Non-Operating: -1,000 to 40,000 ft Reliability Uncorrectable Bit Error Rate (UBER): 1 sector per 10 ^17 bits read Mean Time Between Failures (MTBF): 2,000,000 hours End-to-End data protection Endurance Rating 12 80GB: 45 TBW – 120GB: 70 TBW 160GB: 100 TBW – 240GB: 140 TBW 300GB: 170 TBW – 400GB: 225 TBW 480GB: 275 TBW – 600GB: 330 TBW 800GB: 450 TBW Certifications and Declarations UL*, CE*, C-Tick*, BSMI*, KCC*, Microsoft* WHCK*, VCCI*, SATA-IO 1. Performance values vary by capacity and form factor 2. Performance specifications apply to both compressible and incompressible data 3. 4KB = 4,096 bytes; 8KB = 8,192 bytes 4. MB/s = 1,000,000 bytes/second. 5. Based on Random 4KB QD=1 workload, measured as the time taken for 99.9 percentile of commands to finish the round-trip from host to drive and back to host 6. Measurement taken once the workload has reached steady state but including all background activities required for normal operation and data reliability 7. Defaults to 12V, if both 12V and 5V are present 8. Based on 5V supply 9. Please contact your Intel representative for details on the non-operating temperature range 10. Altitude pressure is simulated in a test chamber; excludes soft error 11. Extended operation at a higher altitude might impact reliability. 12. Based on JESD218 standard Order Number: 328860-008US

Upload: others

Post on 12-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Product Specification Capacity:

− 2.5-inch: 80/120/160/240/300/480/600/800 GB − 1.8-inch: 80/240/400/800 GB

Components: − Intel® 20nm NAND Flash Memory − Multi-Level Cell (MLC)

Form Factor: 2.5–inch and 1.8-inch Read and Write IOPS1,2 (Full LBA Range, IOMeter*

Queue Depth 32) − Random 4KB3 Reads: Up to 75,000 IOPS − Random 4KB Writes: Up to 11,500 IOPS − Random 8KB3 Reads: Up to 47,500 IOPS − Random 8KB Writes: Up to 5,500 IOPS

Bandwidth Performance1 − Sustained Sequential Read: Up to 500 MB/s4 − Sustained Sequential Write: Up to 450 MB/s

Latency (average sequential) − Read: 50 µs (TYP) − Write: 65 µs (TYP)

Quality of Service5, 6 − Read/Write: 500 µs / 5 ms (99.9%)

AES 256-bit Encryption Compliance

− SATA Revision 3.0; compatible with SATA 6Gb/s, 3Gb/s and 1.5Gb/s interface rates

− ATA-ATAPI command Set – 2 (ACS-2); includes SCT (Smart Command Transport) and device statistics log support

− Enhanced SMART ATA feature set − Native Command Queuing (NCQ) command set − Data set management Trim command

Compatibility − Windows* 7 and Windows* 8 − Windows* Server 2012 − Windows* Server 2008 Enterprise 32/64bit SP2 − Windows* Server 2008 R2 SP1 − Windows* Server 2003 Enterprise R2 64bit SP2 − Red Hat* Enterprise Linux* 5.5, 5.6, 6.1, 6.3 − SUSE* Linux* Enterprise Server 10, 11 SP1 − CentOS* 64bit 5.7, 6.3 − Intel® SSD Toolbox with Intel® SSD Optimizer

Product Ecological Compliance − RoHS*

Power Management − 2.5-inch: 5 V or 12 V SATA Supply Rail7 − 1.8-inch: 3.3 V SATA Supply Rail − SATA Interface Power Management − OS-aware hot plug/removal − Enhanced power-loss data protection

Power8 − Active: Up to 5.0 W (TYP) − Idle: 650 mW

Weight − 2.5-inch 80-240GB: 70 grams ± 2 grams − 2.5-inch 300-800GB: 72 grams ± 2 grams − 1.8-inch 80GB: 35 grams ± 2 grams − 1.8-inch 240-800GB: 37 grams ± 2 grams

Temperature − Operating: 0° C to 70° C − Non-Operating9: -55° C to 95° C − Temperature monitoring and logging − Thermal throttling

Shock (operating and non-operating): 1,000 G/0.5 msec

Vibration − Operating: 2.17 GRMS (5-700 Hz) − Non-Operating: 3.13 GRMS (5-800 Hz)

Altitude10 − Operating: -1,000 to 10,000 ft − Operating11: 10,000 to 15,000 ft − Non-Operating: -1,000 to 40,000 ft

Reliability − Uncorrectable Bit Error Rate (UBER):

1 sector per 10^17 bits read − Mean Time Between Failures (MTBF):

2,000,000 hours − End-to-End data protection

Endurance Rating12 − 80GB: 45 TBW – 120GB: 70 TBW − 160GB: 100 TBW – 240GB: 140 TBW − 300GB: 170 TBW – 400GB: 225 TBW − 480GB: 275 TBW – 600GB: 330 TBW − 800GB: 450 TBW

Certifications and Declarations − UL*, CE*, C-Tick*, BSMI*, KCC*, Microsoft* WHCK*, VCCI*,

SATA-IO

1. Performance values vary by capacity and form factor 2. Performance specifications apply to both compressible and incompressible data 3. 4KB = 4,096 bytes; 8KB = 8,192 bytes 4. MB/s = 1,000,000 bytes/second. 5. Based on Random 4KB QD=1 workload, measured as the time taken for 99.9 percentile of commands to finish the round-trip from host to drive and back to host 6. Measurement taken once the workload has reached steady state but including all background activities required for normal operation and data reliability 7. Defaults to 12V, if both 12V and 5V are present 8. Based on 5V supply 9. Please contact your Intel representative for details on the non-operating temperature range 10. Altitude pressure is simulated in a test chamber; excludes soft error 11. Extended operation at a higher altitude might impact reliability. 12. Based on JESD218 standard

Order Number: 328860-008US

Page 2: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Ordering Information

Contact your local Intel sales representative for ordering information.

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.

A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS.

Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.

The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.

Intel Non-Volatile Memory Solutions Group (NSG) states that, through our Software Legal Compliance (SWLC) process, we have examined and evaluated firmware and software components that may accompany this Intel Solid-State Drive product, including embedded SSD firmware and any Intel-provided drivers. We conclude that there are no Open Source elements contained in these components. For more information about our SWLC process, please contact your Intel Representative.

Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.

Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.htm

Low Halogen applies only to brominated and chlorinated flame retardants (BFRs/CFRs) and PVC in the final product. Intel components as well as purchased components on the finished assembly meet JS-709 requirements, and the PCB/substrate meet IEC 61249-2-21 requirements. The replacement of halogenated flame retardants and/or PVC may not be better for the environment.

Intel and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries.

*Other names and brands may be claimed as the property of others.

Copyright © 2015 Intel Corporation. All rights reserved.

Product Specification January 2015 2 328860-008US

Page 3: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Contents

Revision History ........................................................................................................................................................................ 4 Related Documents .................................................................................................................................................................. 4 Terms and Acronyms ............................................................................................................................................................... 5 1.0 Overview ....................................................................................................................................................................... 6 2.0 Product Specifications .............................................................................................................................................. 7

2.1 Capacity ......................................................................................................................................................................................... 7 2.2 Performance ................................................................................................................................................................................ 7 2.3 Electrical Characteristics ....................................................................................................................................................... 9 2.4 Environmental Conditions ................................................................................................................................................. 12 2.5 Product Regulatory Compliance ..................................................................................................................................... 13 2.6 Reliability ................................................................................................................................................................................... 13 2.7 Temperature Sensor ............................................................................................................................................................ 14 2.8 Power Loss Capacitor Test ................................................................................................................................................ 14 2.9 Hot Plug Support ................................................................................................................................................................... 14

3.0 Mechanical Information ......................................................................................................................................... 15 4.0 Pin and Signal Descriptions .................................................................................................................................. 17

4.1 2.5-inch Form Factor Pin Locations .............................................................................................................................. 17 4.2 1.8-inch Form Factor Pin Locations .............................................................................................................................. 17 4.3 Connector Pin Signal Definitions .................................................................................................................................... 18 4.4 Power Pin Signal Definitions............................................................................................................................................. 18

5.0 Supported Command Sets .................................................................................................................................... 20 5.1 ATA General Feature Command Set ............................................................................................................................. 20 5.2 Power Management Command Set............................................................................................................................... 20 5.3 Security Mode Feature Set ................................................................................................................................................ 21 5.4 SMART Command Set ......................................................................................................................................................... 21 5.4.1 Attributes ................................................................................................................................................................................... 21 5.5 Device Statistics ...................................................................................................................................................................... 26 5.6 SMART Command Transport (SCT) ............................................................................................................................... 28 5.7 Data Set Management Command Set .......................................................................................................................... 28 5.8 Host Protected Area Command Set .............................................................................................................................. 28 5.9 48-Bit Address Command Set ......................................................................................................................................... 28 5.10 General Purpose Log Command Set............................................................................................................................. 29 5.11 Native Command Queuing ................................................................................................................................................ 29 5.12 Software Settings Preservation ....................................................................................................................................... 29

6.0 Certifications and Declarations ............................................................................................................................ 30 7.0 References ................................................................................................................................................................ 31 Appendix A: IDENTIFY DEVICE Command Data ............................................................................................................... 32

January 2015 Product Specification 328860-008US 3

Page 4: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Revision History

Revision Description Date

001 Initial release. April 2013

002 1. Random write IOPS consistency changes from 75% to 80% 2. Added read power in table 8, 9 and 11 3. Added X,Y, Z dimension in section 3.0

June 2013

003 1. Updated Section 5.4.2 Timed Workload Endurance Indicators with user notes 2. Updated Table 6 notes 3. Updated Table 23

December 2013

004 1. Page 1: Compliance, Changed from ATA8-ACS2 to ATA9-ACS2 2. Table 18: Changed SMART Attribute E9h, PW and Threshold values from 0 to 1. 3. Table 23: Corrected Error in Default Value for Words 60-62

March 2014

005 1. Page 1: Compliance, changed from ATA9-ACS2 to ATA/ATAPI Command Set – 2 (ACS-2) 2. Table 9: removed duplicate footnote callout 3. Table 10: Title correction

April 2014

006 1. Page 1: Altitude spec change with added footnote (note 10). 2. Table 14: Updated footnote for Reliability table 3. Table 18: Updated SMART attribute B8h description and changed threshold values

September 2014

007 Added Related Documents table for the Intel® Solid-State Drive DC S3500 Series M.2 and 1.2TB/1.6TB Product Specification Addendums November 2014

008 In Section 5.6, added clarification to word 106 of Identify Device Command and SCT command process to change the reported value. January 2015

Related Documents

Title Link

Intel® Solid-State Drive DC S3500 Series M.2 Product Specification Addendum

http://www.intel.com/content/dam/www/public/us/en/documents/product-specifications/ssd-dc-s3500-m2-spec.pdf

Intel® Solid-State Drive DC S3500 Series 1.2TB and 1.6TB Product Specification Addendum

http://www.intel.com/content/dam/www/public/us/en/documents/product-specifications/ssd-dc-s3500-1-2tb-1-6tb-spec.pdf

Product Specification January 2015 4 328860-008US

Page 5: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Terms and Acronyms

Term Definition

ATA Advanced Technology Attachment CRC Cyclic Redundancy Check DAS Device Activity Signal DMA Direct Memory Access ECC Error Correction Code EXT Extended

FPDMA First Party Direct Memory Access

GB Gigabyte Note: The total usable capacity of the SSD may be less than the total physical capacity because a small portion of the capacity is used for NAND flash management and maintenance purposes.

Gb Gigabit HDD Hard Disk Drive HET High Endurance Technology KB Kilobyte I/O Input/Output

IOPS Input/Output Operations Per Second ISO International Standards Organization LBA Logical Block Address MB Megabyte (1,000,000 bytes)

MLC Multi-level Cell MTBF Mean Time Between Failures NCQ Native Command Queuing NOP No Operation PB Petabyte

PBW Peta Bytes Written PCB Printed Circuit Board PIO Programmed Input/Output RDT Reliability Demonstration Test RMS Root Mean Square SATA Serial Advanced Technology Attachment SCT SMART Command Transport

SMART Self-Monitoring, Analysis and Reporting Technology An open standard for developing hard drives and software systems that automatically monitors the health of a drive and reports potential problems.

SSD Solid-State Drive TB Terabyte TB Tera Bytes Written

TYP Typical UBER Uncorrectable Bit Error Rate

January 2015 Product Specification 328860-008US 5

Page 6: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

1.0 Overview

This document describes the specifications and capabilities of the Intel® SSD DC S3500 Series.

The Intel SSD DC S3500 Series delivers leading performance and Quality of Service combined with world-class reliability for Serial Advanced Technology Attachment (SATA)-based computers in nine capacities: 80GB, 120GB, 160GB, 240GB, 300GB, 400GB, 480GB, 600GB and 800GB.

By combining 20nm Intel® NAND Flash Memory technology with SATA 6Gb/s interface support, the Intel® SSD DC S3500 Series delivers sequential read speeds of up to 500MB/s and sequential write speeds of up to 450MB/s. Intel SSD DC S3500 Series delivers Quality of Service of 500 µs for random 4KB reads measured at a queue depth of 1. (See Table 6.)

The industry-standard 2.5-inch and 1.8-inch form factors enable interchangeability with existing hard disk drives (HDDs) and native SATA HDD drop-in replacement with the enhanced performance, reliability, ruggedness, and power savings offered by an SSD.

Intel SSD DC S3500 Series offers these key features:

• Standard Endurance Technology • High I/O and throughput performance • Consistent I/O latency • Enhanced power-loss data protection • End-to-End data protection • Thermal throttling • Temperature Sensor • Inrush current management • Low power • High reliability • Enhanced ruggedness • Temperature monitor and logging • Power loss protection capacitor self-test

Product Specification January 2015 6 328860-008US

Page 7: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

2.0 Product Specifications

2.1 Capacity

Table 1: User Addressable Sectors

Intel® SSD DC S3500 Series Unformatted Capacity

(Total User Addressable Sectors in LBA Mode)

80GB 156,301,488

120GB 234,441,648

160GB 312,581,808

240GB 468,862,128

300GB 586,072,368

400GB 781,422,768

480GB 937,703,088

600GB 1,172,123,568

800GB 1,562,824,368

Notes: 1GB = 1,000,000,000 bytes; 1 sector = 512 bytes LBA count shown represents total user storage capacity and will remain the same throughout the life of the drive. The total usable capacity of the SSD may be less than the total physical capacity because a small portion of the capacity is used for NAND flash management and maintenance purposes.

2.2 Performance

Table 2: Random Read/Write Input/Output Operations Per Second (IOPS)

Specification1 Unit

Intel SSD DC S3500 Series

80GB (2.5/ 1.8”)

120GB 160GB 240GB (2.5”/ 1.8”)

300GB 400GB (1.8”)

480 /600GB

800GB (2.5”/ 1.8”)

Random 4KB Read (up to)2 IOPS 70,000 75,000 75,000 75,000 75,000 75,000 75,000 75,000

Random 4KB Write (up to) IOPS 7,000 4,600 7,500 7,500 9,000 11,000 11,000 11,500

Random 8KB Read (up to)3 IOPS 39,000 47,000 47,500 47,500 47,500 47,500 47,500 47,500

Random 8KB Write (up to) IOPS 3,700 2,300 3,800 3,800 4,400 5,500 5,500 5,500

Notes: 1. Performance measured using Iometer* with Queue Depth 32. Measurements are performed on a full Logical Block Address (LBA) span of

the drive. 2. 4KB = 4,096 bytes 3. 8KB = 8,192 bytes

January 2015 Product Specification 328860-008US 7

Page 8: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 3: Random Read/Write IOPS Consistency

Specification1 Unit

Intel® SSD DC S3500 Series

80GB (2.5/ 1.8”)

120GB 160GB 240GB (2.5”/ 1.8”)

300GB 400GB (1.8”)

480 / 600 GB

800GB (2.5”/ 1.8”)

Random 4 KB Read (up to)2 % 90 90 90 90 90 90 90 90

Random 4 KB Write (up to) % 80 80 80 80 80 80 80 80

Random 8 KB Read (up to)3 % 90 90 90 90 90 90 90 90

Random 8 KB Write (up to) % 80 80 80 80 80 80 80 80

Notes: 1. Performance consistency measured using IOMeter* based on Random 4KB QD=32 workload, measured as the (IOPS in the 99.9th

percentile slowest 1-second interval)/(average IOPS during the test). Measurements are performed on a full Logical Block Address (LBA) span of the drive once the workload has reached steady state but including all background activities required for normal operation and data reliability.

2. 4KB = 4,096 bytes 3. 8KB = 8,192 bytes

Table 4: Sequential Read and Write Bandwidth

Specification Unit

Intel SSD DC S3500 Series

80GB (2.5/ 1.8”)

120GB 160GB 240GB (2.5”/ 1.8”)

300GB 400GB (1.8”)

480 /600 GB

800GB (2.5”/ 1.8”)

Sequential Read (SATA 6Gb/s)1 MB/s 340 445 475 500 500 500 500 500

Sequential Write (SATA 6Gb/s)1 MB/s 100 135 175 260 315 380 410 450

Note: 1. Performance measured using IOMeter* with 128 KB (131,072 bytes) of transfer size with Queue Depth 32.

Table 5: Latency

Specification

Intel SSD DC S3500 Series

80GB (2.5/1.8”), 120GB, 160GB, 240GB (2.5”/1.8”), 300GB, 400GB (1.8”), 480GB, 600GB

800GB (2.5”/1.8”)

Latency1 (TYP) Read Write Power On to Ready2

50 µs 65 µs 2.0 s

50 µs 65 µs 3.0 s

Notes: 1. Device measured using IOMeter. Latency measured using 4KB (4,096 bytes) transfer size with Queue Depth equal to 1 on a sequential workload. 2. Power On To Ready time assumes proper shutdown. Time varies if shutdown is not preceded by STANDBY IMMEDIATE command. For 95% of

the time, the maximum time for power on to ready will be less than 10 seconds.

Product Specification January 2015 8 328860-008US

Page 9: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 6: Quality of Service

Specification Unit

Intel® SSD DC S3500 Series

Queue Depth=1 Queue Depth=32

80/120/160/ 240GB

300/400/480/600/800GB

80/120/160/ 240GB

300/400/480/600/800GB

Quality of Service1, 2 (99.9%)

Reads ms 0.5 0.5 2 2

Writes ms 5 2 20 10

Quality of Service1,2 (99.9999%)

Reads ms 10 5 10 5

Writes ms 10 10 30 30

Notes: 1. Device measured using IOMeter. Quality of Service measured using 4KB (4,096 bytes) transfer size on a random workload on a full Logical

Block Address (LBA) span of the drive once the workload has reached steady state but including all background activities required for normal operation and data reliability.

2. Based on Random 4KB QD=1, 32 workloads, measured as the time taken for 99.9(or 99.9999) percentile of commands to finish the round-trip from host to drive and back to host.

2.3 Electrical Characteristics

Table 7: Operating Voltage for 2.5-inch Form Factor

Electrical Characteristics Intel SSDDC S3500 Series

80GB, 120GB, 160GB, 240GB, 300GB, 480GB, 600GB, 800GB

5 V Operating Characteristics: Operating Voltage range Rise time (Max/Min) Fall time (Min)2 Noise level Min Off time3 Inrush Current (Typical Peak) 1

5 V (±5%) 1 s / 1 ms

1 ms 500 mV pp 10 Hz – 100 KHz 50 mV pp 100 KHz – 20 MHz

500 ms 1.0 A, < 1 s

12 V Operating Characteristics: Operating Voltage range Rise time (Max/Min) Fall time (Min)2 Noise level Min Off time3 Inrush Current (Typical Peak) 1

12 V (±10%) 1 s / 1 ms

1 ms 1000 mV pp 10 Hz – 100 KHz 100 mV pp 100 KHz – 20 MHz

500 ms 1.0 A, < 1 s

Notes: 1. Measured from initial device power supply application. 2. Fall time needs to be equal or better than minimum in order to guarantee full functionality of enhanced power loss management. 3. The drive needs to be powered off for at least 500msec before powering on.

January 2015 Product Specification 328860-008US 9

Page 10: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 8: Power Consumption for 2.5-inch Form Factor (5V Supply)

Specification Unit Intel® SSD DC S3500 Series

80GB 120GB 160GB 240GB 300GB 480GB 600GB 800GB

Active Write - RMS Average 1 W 1.8 2.0 2.3 2.9 3.5 4.3 4.5 5.0

Active Write –RMS Burst 2 W 2.0 2.4 2.7 3.2 3.9 5.2 5.5 7.3

Active Read - RMS Average 3 W 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6

Active Read - RMS Burst 4 W 1.8 2.2 2.5 2.8 3.0 3.3 3.4 3.5

Idle W 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6

Notes: 1. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) average power is

measured using scope trigger over a 100 ms sample period. 2. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) burst power is measured

using scope trigger over a 500 µs sample period. 3. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) average power is measured

using scope trigger over a 100 ms sample period. 4. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) burst power is measured

using scope trigger over a 500 µs sample period.

Table 9: Power Consumption for 2.5-inch Form Factor (12V Supply)

Specification Unit Intel® SSD DC S3500 Series

80GB 120GB 160GB 240GB 300GB 480GB 600GB 800GB

Active Write - RMS Average1 W 2.0 2.3 2.5 3.1 3.5 4.3 4.5 5.0

Active Write - Burst2 W 2.2 2.5 2.8 3.4 4.2 5.5 6.8 7.8

Active Read - RMS Average3 W 1.6 1.6 1.7 1.7 1.7 1.7 1.7 1.8

Active Read - RMS Burst4 W 2.1 2.3 2.6 3.2 3.6 3.6 3.6 6.4

Idle W 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9

Notes: 1. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) average power is

measured using scope trigger over a 100 ms sample period. 2. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) burst power is measured

using scope trigger over a 500 µs sample period. 3. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) average power is measured

using scope trigger over a 100 ms sample period. 4. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) burst power is measured

using scope trigger over a 500 µs sample period.

Product Specification January 2015 10 328860-008US

Page 11: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 10: Operating Voltage for 1.8-inch Form Factor

Electrical Characteristics Intel® SSD DC S3500 Series

80GB 240GB 400GB 800GB

Operating Voltage for 3.3 V (±5%) Min Max Rise time (Max/Min) Fall time (Min)2 Noise level Min Off time3

3.13 V 3.47 V

1 s / 1 ms 1 ms

300 mV pp 10 Hz – 100 KHz 500 mV pp 100 KHz – 20 MHz

500 ms

Inrush Current (Typical Peak) 1 1.2 A, < 1 s

Notes: 1. Measured from initial device power supply application. 2. Fall time needs to be equal or better than minimum in order to guarantee full functionality of enhanced power loss management. 3. The drive needs to be powered off for at least 500msec before powering on.

Table 11: Power Consumption for 1.8-inch Form Factor

Specification1 Unit Intel SSD DC S3500 Series

80GB 240GB 400GB 800GB

Active Write - RMS Average @ 3.3V W 2.0 3.5 4.5 5.2

Active Write - RMS Burst @ 3.3V W 2.2 3.8 5.0 7.5

Active Read - RMS Average @ 3.3V W 1.3 1.4 1.4 1.4

Active Read - RMS Burst @ 3.3V W 1.8 2.6 3.0 3.0

Idle @ 3.3V W 0.6 0.6 0.6 0.6

Note: 1. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. Root Mean Squared (RMS) power is measured using

scope trigger over a 100 ms sample period.

January 2015 Product Specification 328860-008US 11

Page 12: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

2.4 Environmental Conditions

Table 12: Temperature, Shock, Vibration

Temperature Range

Case Temperature Operating Non-operating1

0 – 70 oC

-55 – 95 oC

Temperature Gradient2

Operating Non-operating

30 oC/hr (Typical) 30 oC/hr (Typical)

Humidity Operating Non-operating

5 – 95 % 5 – 95 %

Shock and Vibration Range

Shock3

Operating Non-operating

1,000 G (Max) at 0.5 msec 1,000 G (Max) at 0.5 msec

Vibration4

Operating Non-operating

2.17 GRMS (5-700 Hz) Max 3.13 GRMS (5-800 Hz) Max

Notes: 1. Contact your Intel representative for details on the non-operating temperature range. 2. Temperature gradient measured without condensation. 3. Shock specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus may be

applied in the X, Y or Z axis. Shock specification is measured using Root Mean Squared (RMS) value. 4. Vibration specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus may be

applied in the X, Y or Z axis. Vibration specification is measured using RMS value.

Product Specification January 2015 12 328860-008US

Page 13: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

2.5 Product Regulatory Compliance

Intel® SSD DC S3500 Series meets or exceeds the regulatory or certification requirements listed in the following table:

Table 13: Product Regulatory Compliance Specifications

Title Description Region For Which

Conformity Declared

TITLE 47-Telecommunications CHAPTER 1— FEDERAL COMMUNMICATIONS COMMISSION PART 15 — RADIO FREQUENCY DEVICES ICES-003, Issue 4 Interference-Causing Equipment Standard Digital Apparatus

FCC Part 15B Class B CA/CSA-CEI/IEC CISPR 22:02. This is CISPR 22:1997 with Canadian Modifications

USA

Canada

IEC 55024 Information Technology Equipment — Immunity characteristics— Limits and methods of measurement CISPR24:2010

EN-55024: 1998 and its amendments European Union

IEC 55022 Information Technology Equipment — Radio disturbance Characteristics— Limits and methods of measurement CISPR24:2008 (Modified)

EN-55022: 2006 and its amendments European Union

EN-60950-1 2nd Edition Information Technology Equipment — Safety — Part 1: General Requirements

USA/Canada

UL/CSA EN-60950-1 2nd Edition Information Technology Equipment — Safety — Part 1: General Requirements

USA/Canada

2.6 Reliability

Intel® SSD DC S3500 Series meets or exceeds SSD endurance and data retention requirements as specified in the JESD218 standard. Reliability specifications are listed in the following table:

Table 14: Reliability Specifications

Parameter Value

Uncorrectable Bit Error Rate (UBER)

< 1 sector per 1017 bits read Uncorrectable bit error rate will not exceed one sector in the

specified number of bits read. In the unlikely event of a non-recoverable read error, the SSD will report it as a read failure to the host; the sector in error is considered corrupt and is not returned to the host.

Mean Time Between Failures (MTBF)

2 million hours Mean Time Between Failures is estimated based on Telcordia* methodology and demonstrated through Reliability Demonstration Test (RDT).

January 2015 Product Specification 328860-008US 13

Page 14: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Parameter Value

Power On/Off Cycles

24 per day Power On/Off Cycles is defined as power being removed from the SSD, and then restored. Most host systems remove power from the SSD when entering suspend and hibernate as well as on a system shutdown.

Insertion Cycles SATA/power cable insertion/removal cycles.

50 on SATA cable 500 on backplane

Data Retention 3 months power-off retention once SSD reaches rated write endurance at 40 °C The time period for retaining data in the NAND at maximum rated

endurance.

Endurance Rating 80 GB: 45 TBW

120 GB:70 TBW

160 GB: 100 TBW

240 GB: 140 TBW

300 GB: 170 TBW 400 GB: 225 TBW 480 GB: 275 TBW 600 GB: 330 TBW

800 GB: 450 TBW

While running JESD218 standard1 and based on JESD219 workload.

Note:

1. Refer to JESD218 standard table 1 for UBER, FFR and other Enterprise SSD endurance verification requirements. UBER design and majority of life target is 1E-17. Endurance verification acceptance criterion based on establishing <1E-16 at 60 confidence.

2.7 Temperature Sensor

The Intel® SSD DC S3500 Series has an internal temperature sensor with an accuracy of +/-2C over a range of -20C to +80C which can be monitored using two SMART attributes: Airflow Temperature (BEh) and Device Internal Temperature (C2h).

For more information on supported SMART attributes, see “SMART Attributes” on page 20.

2.8 Power Loss Capacitor Test

The Intel SSD DC S3500 Series supports testing of the power loss capacitor, which can be monitored using the following SMART attribute: (175, AFh).

2.9 Hot Plug Support

Hot Plug insertion and removal is supported in the presence of a proper connector and appropriate operating system (OS), as described in the SATA 3.0 specification.

This product supports asynchronous signal recovery and issues an unsolicited COMINIT when first mated with a powered connector to guarantee reliable detection by a host system without hardware device detection.

Product Specification January 2015 14 328860-008US

Page 15: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

3.0 Mechanical Information

Figures 1 and 2 show the physical package information for the Intel® SSD DC S3500 Series in the 2.5-inch and 1.8-inch form factors. All dimensions are in millimeters.

Figure 1: Intel SSD DC S3500 Series 2.5-inch Dimensions

X – Length -- * Y - Width Z - Height

100.45 Max 69.85 +/- 0.25 7.0 +0/-0.5

* - does not include 0.3 connector protrusion

January 2015 Product Specification 328860-008US 15

Page 16: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Figure 2: Intel® SSD DC S3500 Series 1.8 inch Dimensions

X - Length Y - Width Z - Height

78.50 +/- 0.60 54.0 +/- 0.25 5.0 +/- 0.35

Product Specification January 2015 16 328860-008US

Page 17: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

4.0 Pin and Signal Descriptions

4.1 2.5-inch Form Factor Pin Locations

Figure 3: Layout of 2.5-inch Form Factor Signal and Power Segment Pins

Note: 2.5-inch connector supports built in latching capability.

4.2 1.8-inch Form Factor Pin Locations

Figure 4: Layout of 1.8-inch Form Factor Signal and Power Segment Pins

January 2015 Product Specification 328860-008US 17

Page 18: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

4.3 Connector Pin Signal Definitions

Table 15: Serial ATA Connector Pin Signal Definitions—2.5-inch and 1.8-inch Form Factors

Pin Function Definition

S1 Ground 1st mate

S2 A+ Differential signal pair A

S3 A-

S4 Ground 1st mate

S5 B- Differential signal pair B

S6 B+

S7 Ground 1st mate

Note: Key and spacing separate signal and power segments.

4.4 Power Pin Signal Definitions

Table 16: Serial ATA Power Pin Definitions—2.5-inch Form Factors

Pin1 Function Definition Mating Order

P12 Not connected (3.3 V Power) --

P22 Not connected (3.3 V Power) --

P32 Not connected (3.3 V Power; pre-charge) 2nd Mate

P43,4 Ground Ground 1st Mate

P53 Ground Ground 1st Mate

P63 Ground Ground 1st Mate

P73,5 V5 5 V Power 1st Mate

P83,5 V5 5 V Power 2nd Mate

P93,5 V5 5 V Power 2nd Mate

P103 Ground Ground 1st Mate

P116 DAS/DSS Device Activity Signal/Disable Staggered Spin-up

2nd Mate

P123,4 Ground Ground 1st Mate

P137 V12 12 V Power 1st Mate

P147 V12 12 V Power 2nd Mate

P157 V12 12 V Power 2nd Mate

Notes: 1. All pins are in a single row, with a 1.27 mm (0.050-inch) pitch. 2. Pins P1, P2 and P3 are connected together, although they are not connected internally to the device. The host may put 3.3 V on these pins. 3. The mating sequence is:

• ground pins P4-P6, P10, P12 and the 5V power pin P7 • signal pins and the rest of the 5V power pins P8-P9

4. Ground connectors P4 and P12 may contact before the other 1st mate pins in both the power and signal connectors to discharge ESD in a suitably configured backplane connector.

5. Power pins P7, P8, and P9 are internally connected to one another within the device. 6. The host may ground P11 if it is not used for Device Activity Signal (DAS). 7. Pins P13, P14 and P15 are internally connected to one another within the device. The host may put 12 V on these pins.

Product Specification January 2015 18 328860-008US

Page 19: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 17: Serial ATA Power Pin Definitions—1.8-inch Form Factors

Pin Function Definition Mating Order1

P12 V33 3.3 V Power 2nd Mate

P22 V33 3.3 V Power, per-charge 2nd Mate

P33 Ground -- 1st Mate

P43 Ground -- 1st Mate

P54 V5 5 V Power; not connected. 1st Mate

P64 V5 5 V Power; not connected. 2nd Mate

P75 DAS/DSS Device Activity Signal/Disable Staggered Spin-up

2nd Mate

Key Key NC NC

P86 Optional Manufacturing Test Pin 2nd Mate

P96 Optional Manufacturing Test Pin 2nd Mate

Notes: 1. All mate sequences assume zero angular offset between connectors. 2. P1 and P2 are internally connected to one another within the device. 3. Ground connectors P3 and P4 may contact before the other 1st mate pins in both the power and signal connectors to discharge ESD in a

suitably configure backplane connector. 4. Pins P5 and P6 are not connected internally to the device but there is an option to connect through a zero ohm stuffing resistor. The

host may put 5V on these pins. 5. The host may ground P7 if it is not used for Device Activity Signal (DAS). 6. P8 and P9 should not be connected by the host.

January 2015 Product Specification 328860-008US 19

Page 20: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

5.0 Supported Command Sets

Intel® SSD DC S3500 Series supports all mandatory ATA (Advanced Technology Attachment) commands defined in the ATA8-ACS specification described in this section.

5.1 ATA General Feature Command Set

The Intel SSD DC S3500 Series supports the ATA General Feature command set (non- PACKET), which consists of:

− EXECUTE DEVICE DIAGNOSTIC − SET FEATURES − IDENTIFY DEVICE

Note: See Appendix A, “IDENTIFY DEVICE Command Data” on page 29 for details on the sector data returned after issuing an IDENTIFY DEVICE command.

Intel SSD DC S3500 Series also supports the following optional commands:

− READ DMA − WRITE DMA − READ SECTOR(S) − READ VERIFY SECTOR(S) − READ MULTIPLE − SEEK − SET FEATURES − WRITE SECTOR(S) − SET MULTIPLE MODE1 − WRITE MULTIPLE − FLUSH CACHE − READ BUFFFER − WRITE BUFFER − NOP − DOWNLOAD MICROCODE − WRITE UNCORRECTABLE EXT

1. The only multiple supported will be multiple 1

5.2 Power Management Command Set

Intel SSD DC S3500 Series supports the Power Management command set, which consists of:

− CHECK POWER MODE − IDLE − IDLE IMMEDIATE − SLEEP − STANDBY − STANDBY IMMEDIATE

Product Specification January 2015 20 328860-008US

Page 21: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

5.3 Security Mode Feature Set

Intel SSD DC S3500 Series supports the Security Mode command set, which consists of:

− SECURITY SET PASSWORD − SECURITY UNLOCK − SECURITY ERASE PREPARE − SECURITY ERASE UNIT − SECURITY FREEZE LOCK − SECURITY DISABLE PASSWORD

5.4 SMART Command Set

Intel® SSD DC S3500 Series supports the SMART command set, which consists of:

− SMART READ DATA − SMART READ ATTRIBUTE THRESHOLDS − SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE − SMART SAVE ATTRIBUTE VALUES − SMART EXECUTE OFF-LINE IMMEDIATE − SMART READ LOG SECTOR − SMART WRITE LOG SECTOR − SMART ENABLE OPERATIONS − SMART DISABLE OPERATIONS − SMART RETURN STATUS − SMART ENABLE/DISABLE AUTOMATIC OFFLINE

5.4.1 Attributes

The following table lists the SMART attributes supported by the Intel SSD DC S3500 Series and the corresponding status flags and threshold settings.

Table 18: SMART Attributes

ID Attribute Status Flags

Threshold SP EC ER PE OC PW

05h

Re-allocated Sector Count Raw value: shows the number of retired blocks since

leaving the factory (grown defect count). Normalized value: beginning at 100, shows the percent

remaining of allowable grown defect count.

1 1 0 0 1 0 0 (none)

09h

Power-On Hours Count Raw value: reports power-on time, cumulative over the

life of the SSD, integer number in hour time units. Normalized value: always 100.

1 1 0 0 1 0 0 (none)

0Ch

Power Cycle Count Raw value: reports the cumulative number of power cycle events over the life of the device.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

AAh Available Reserved Space (See Attribute E8) 1 1 0 0 1 1 10

ABh

Program Fail Count Raw value: shows total count of program fails. Normalized value: beginning at 100, shows the percent remaining of allowable program fails.

1 1 0 0 1 0 0 (none)

January 2015 Product Specification 328860-008US 21

Page 22: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

ID Attribute Status Flags

Threshold SP EC ER PE OC PW

ACh

Erase Fail Count Raw value: shows total count of erase fails. Normalized value: beginning at 100, shows the percent remaining of allowable erase fails.

1 1 0 0 1 0 0 (none)

AEh

Unexpected Power Loss Also known as “Power-off Retract Count” per magnet-ic-drive terminology. Raw value: reports number of unclean shutdowns, cu-mulative over the life of the SSD. An “unclean shutdown” is the removal of power without STANDBY IMMEDIATE as the last command (regardless of PLI activity using capacitor power). Normalized value: always 100.

1 1 0 0 1 0 0 (none)

AFh

Power Loss Protection Failure Last test result as microseconds to discharge cap, satu-rates at max value. Also logs minutes since last test and lifetime number of tests.

Raw value: Bytes 0-1: Last test result as microseconds to discharge

cap, saturates at max value. Test result expected in range 25 <= result <= 5000000, lower indicates specific error code.

Bytes 2-3: Minutes since last test, saturates at max value.

Bytes 4-5: Lifetime number of tests, not incremented on power cycle, saturates at max value.

Normalized value: set to 1 on test failure or 11 if the capacitor has been tested in an excessive temperature condition, otherwise 100.

1 1 0 0 1 1 10

B7h

SATA Downshift Count Raw value: reports number of times SATA interface selected lower signaling rate due to error. Normalized value: always 100.

1 1 0 0 1 0 0 (none)

B8h

End-to-End Error Detection Count Raw value: reports number of LBA tag mismatches in end-to-end data protection path. Normalized value: always 100.

1 1 0 0 1 1 90

BBh

Uncorrectable Error Count The raw value shows the count of errors that could not be recovered using Error Correction Code (ECC). Normalized value: always 100.

1 1 0 0 1 0 0 (none)

BEh

Temperature - Airflow Temperature (Case) Raw value: reports SSD case temperature statistics.

Bytes 0-1: Current case temperature, Celsius Byte 2: Recent min case temperature, Celsius Byte 3: Recent max case temperature, Celsius Bytes 4-5: Over temperature counter. Number of times sampled temperature exceeds drive max operating temperature specification.

Normalized value: 100 – case temperature in C degrees.

1 0 0 0 1 0 0 (none)

Product Specification January 2015 22 328860-008US

Page 23: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

ID Attribute Status Flags

Threshold SP EC ER PE OC PW

C0h

Power-Off Retract Count (Unsafe Shutdown Count) Raw value: reports the cumulative number of unsafe

(unclean) shutdown events over the life of the device. An unsafe shutdown occurs whenever the device is powered off without STANDBYIMMEDIATE being the last command.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

C2h

Temperature - Device Internal Temperature Raw value: Reports internal temperature of the SSD in degrees Celsius. Temperature reading is the value direct from the printed circuit board (PCB) sensor without offset. Normalized value: 150 – device temperature in C degrees, 100 if device temperature less than 50.

1 0 0 0 1 0 0 (none)

C5h

Pending Sector Count Raw value: number of current unrecoverable read

errors that will be re-allocated on next write. Normalized value: always 100.

0 1 0 0 1 0 0 (none)

C7h

CRC Error Count Raw value: shows total number of encountered SATA

interface cyclic redundancy check (CRC) errors. Normalized value: always 100.

1 1 0 0 1 0 0 (none)

E1h

Host Writes Raw value: reports total number of sectors written by the

host system. The raw value is increased by 1 for every 65,536 sectors (32MB) written by the host.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

E2h

Timed Workload Media Wear Raw value: measures the wear seen by the SSD (since

reset of the workload timer, attribute E4h), as a percentage of the maximum rated cycles. Divide the raw value by 1024 to derive the percentage with 3 decimal points.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

E3h

Timed Workload Host Read/Write Ratio Raw value: shows the percentage of I/O operations that

are read operations (since reset of the workload timer, attribute E4h). Reported as integer percentage from 0 to 100.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

E4h

Timed Workload Timer Raw value: measures the elapsed time (number of

minutes since starting this workload timer). Normalized value: always 100.

1 1 0 0 1 0 0 (none)

E8h

Available Reserved Space Raw value: reports number of reserve blocks remaining. Normalized value: begins at 100 , which corresponds

to 100 percent availability of the reserved space. The threshold value for this attribute is 10 percent availability.

1 1 0 0 1 1 10

January 2015 Product Specification 328860-008US 23

Page 24: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

ID Attribute Status Flags

Threshold SP EC ER PE OC PW

E9h

Media Wearout Indicator Raw value: always 0. Normalized value: reports the number of cycles the

NAND media has undergone. Declines linearly from 100 to 1 as the average erase cycle count increases from 0 to the maximum rated cycles.

Once the normalized value reaches 1, the number will not decrease, although it is likely that significant additional wear can be put on the device.

1 1 0 0 1 1 1

EAh

Thermal Throttle Status Raw value: reports Percent Throttle Status and Count of events

Byte 0: Throttle status reported as integer percentage. Bytes 1-4: Throttling event count. Number of times thermal throttle has activated. Preserved over power cy-cles. Byte 5: Reserved.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

F1h

Total LBAs Written Raw value: reports the total number of sectors written

by the host system. The raw value is increased by 1 for every 65,536 sectors (32MB) written by the host.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

F2h

Total LBAs Read Raw value: reports the total number of sectors read by

the host system. The raw value is increased by 1 for every 65,536 sectors (32MB) read by the host.

Normalized value: always 100.

1 1 0 0 1 0 0 (none)

Table 19: SMART Attribute Status Flags

Status Flag Description Value = 0 Value = 1

SP Self-preserving attribute Not a self-preserving attribute Self-preserving attribute

EC Event count attribute Not an event count attribute Event count attribute

ER Error rate attribute Not an error rate attribute Error rate attribute

PE Performance attribute Not a performance attribute Performance attribute

OC Online collection attribute Collected only during offline

activity Collected during both offline and online activity

PW Pre-fail warranty attribute Advisory Pre-fail

5.4.2 Timed Workload Endurance Indicators

Timed Workload Media Wear Indicator — ID E2h

This attribute tracks the drive wear seen by the device during the last wear timer loop, as a percentage of the maximum rated cycles. The raw value tracks the percentage up to 3 decimal points. This value should be divided by 1024 to get the percentage.

For example: if the raw value is 4450, the percentage is 4450/1024 = 4.345%. The raw value is held at FFFFh until the wear timer (attribute E4h) reaches 60 (minutes) after a SMART EXECUTE OFFLINE IMMEDIATE (B0h/D4h) subcommand 40h to the SSD. The normalized value is always set to 100 and should be ignored.

Product Specification January 2015 24 328860-008US

Page 25: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Timed Workload Host Reads Percentage — ID E3h

This attribute shows the percentage of I/O operations that are read operations during the last workload timer loop. The raw value tracks this percentage and is held at FFFFh until the workload timer (attribute E4h) reaches 60 (minutes). The normalized value is always set to 100 and should be ignored.

Workload Timer — ID E4h

This attribute is used to measure the time elapsed during the current workload. The attribute is reset when a SMART EXECUTE OFFLINE IMMEDIATE (D4h) subcommand 40h is issued to the drive. The raw value tracks the time in minutes and has a maximum value of 2^32 = 4,294,967,296 minutes (8,171 years). The normalized value is always set to 100 and should be ignored.

User Notes

• Sending a SMART EXECUTE OFFLINE IMMEDIATE (B0h/D4h) subcommand 40h to the SSD resets and starts all three attributes (Media Wear Indicator, Attribute E2h, Host Reads Percentage, Attribute E3h, and the Workload timer, Attribute E4h) to FFFFh.

• The Attribute raw values are held at FFFFh until the Workload timer (Attribute E4h) reaches a total of 60 (minutes) of power on time. After 60 minutes, the Timed Workload data is made available.

• After the Workload timer (E4h) reaches 60 (minutes), the Timed Workload data is saved every minute so only 59 seconds of data is lost if power is removed without receiving ATA STANDBY IMMEDIATE. Accumulated data is not reset due to power loss.

• Upon power up, the attributes hold a snapshot of their last saved values for 59 seconds and live data is available after 60 seconds, once the initial one hour interval is completed.

Example Use Cases

The Timed Workload Endurance attributes described in this section are intended to be used to measure the amount of media wear that the drive is subjected to during a timed workload.

Ideally, the system that the drive is being used in should be capable of issuing SMART commands. Otherwise, provisions have been provided to allow the media wear attributes to be persistent so the drive can be moved to a SMART capable system to read out the drive wear attribute values.

Use Case 1 – With a System Capable of SMART Commands

1. On a SMART capable system, issue the SMART EXECUTE OFF-LINE IMMEDIATE (D4h) sub-command 40h to reset the drive wear attributes.

2. Run the workload to be evaluated for at least 60 minutes. Otherwise the drive wear attributes will not be available.

3. Read out the drive wear attributes with the SMART READ DATA (D0h) command.

Use Case 2 – With a System Not Capable of SMART Commands

1. On a SMART capable system, issue the SMART EXECUTE OFF-LINE IMMEDIATE (D4h) sub-command 40h to reset the the drive wear attributes.

2. Move the drive to the system where the workload will be measured (and not capable of SMART commands).

3. Run the workload to be evaluated for at least 60 minutes. Otherwise the drive wear attributes will not be available.

4. Do a clean system power down by issuing the ATA STANDBY IMMEDIATE command prior to shutting down the system. This will store all the drive wear SMART attributes to persistent memory within the drive.

January 2015 Product Specification 328860-008US 25

Page 26: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

5. Move the drive to a SMART capable system.

6. Read out the drive wear attributes with the SMART READ DATA (D0h) command within 59 seconds after power-up.

Example Calculation of Drive Wear

The following is an example of how the drive wear attributes can be used to evaluate the impact of a given workload. The Host Writes SMART attribute (E1h) can also be used to calculate the amount of data written by the host during the workload by reading this attribute before and after running the workload. This example assumes that the steps shown in “Example Use Cases” on page 18 were followed to obtain the following attribute values:

• Timed Workload Media Wear (E2h) has a raw value of 16. Therefore, the percentage wear = 16/1024 = 0.016%.

• Timed Workload Host Read/Write Ratio (E3h) has a normalized value of 80, indicating that 80% of operations were reads.

• Workload Timer (E4h) has a raw value of 500. Therefore the workload ran for 500 minutes.

• Host Writes Count (E1h) had a raw value of 100,000 prior to running the workload and a value of 130,000 at the end of the workload. Therefore, the number of sectors written by the host during the workload was 30,000 * 65,535 = 1,966,050,000 sectors or 1,966,050,000 * 512/1,000,000,000 = 1,007 GB.

The following conclusions can be made for this example case:

The workload took 500 minutes to complete with 80% reads and 20% writes. A total of 1,007 GB of data was written to the device, which increased the media wear in the drive by 0.016%. At this point in time, this workload is causing a wear rate of 0.016% for every 500 minutes, or 0.00192%/hour.

5.4.3 SMART Logs

Intel SSD DC S3500 Series implements the following Log Addresses: 00h, 02h, 03h, 06h, and 07h.

DC S3500 Series implements host vendor specific logs (addresses 80h-9Fh) as read and write scratchpads, where the default value is zero (0). Intel SSD DC S3500 does not write any specific values to these logs unless directed by the host through the appropriate commands.

DC S3500 Series also implements a device vendor specific log at address A9h as a read-only log area with a default value of zero (0).

5.5 Device Statistics

In addition to the SMART attribute structure, statistics pertaining to the operation and health of the Intel SSD DC S3500 Series can be reported to the host on request through the Device Statistics log as defined in the ATA specification.

The Device Statistics log is a read-only GPL/SMART log located at read log address 0x04 and is accessible using READ LOG EXT, READ LOG DMA EXT or SMART READ LOG commands.

Table 20 lists the Device Statistics supported by the Intel SSD DC S3500 Series.

Product Specification January 2015 26 328860-008US

Page 27: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Table 20: Device Statistics Log

Page Offset Description Equivalent SMART

attribute (if applicable)

0x00 -- List of Supported Pages --

0x01 – General Statistics

0x08 Power Cycle Count 0Ch

0x10 Power-On Hours 09h

0x18 Logical Sectors Written E1h

0x20 Num Write Commands – incremented by one for every host write

--

0x28 Logical Sectors Read F2h

0x30 Num Read Commands – incremented by one for every host read

--

0x04 – General Error Statistics 0x08 Num Reported Uncorrectable Errors BBh

0x10 Num Resets Between Command Acceptance and Completion

--

0x05 – Temperature Statistics

0x00 Device Statistics Information Header --

0x08 Current Temperature --

0x10 Average Short Term Temperature --

0x18 Average Long Term Temperature --

0x20 Highest Temperature --

0x28 Lowest Temperature --

0x30 Highest Average Short Term Temperature --

0x38 Lowest Average Short Term Temperature --

0x40 Highest Average Long Term Temperature --

0x48 Lowest Average Long Term Temperature --

0x50 Time in Over-Temperature --

0x58 Specified Maximum Operating Temperature --

0x60 Time in Under-Temperature --

0x68 Specified Minimum Operating Temperature --

0x06 – Transport Statistics

0x08 Number of Hardware Resets --

0x10 Number of ASR Events --

0x18 Number of Interface CRC Errors --

0x07 – Solid State Device Statistics

0x08 Percentage Used Endurance Indicator

E9h Note: This device

statistic counts from 1 to 150

January 2015 Product Specification 328860-008US 27

Page 28: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

5.6 SMART Command Transport (SCT)

With SMART Command Transport (SCT), a host can send commands and data to an SSD and receive status and data from an SSD using standard write/read commands to manipulate two SMART Logs:

− Log Address E0h ("SCT Command/Status") — used to send commands and retrieve status − Log Address E1h ("SCT Data Transfer") — used to transport data

Intel® SSD DC S3500 Series supports the following standard SCT actions:

− Write Same — DC S3500 Series implements this action code as described in the ATA specification − Error Recovery Control — DC S3500 Series accepts this action code, and will store and return error-recovery

time limit values − Feature Control - DC S3500 Series supports feature code 0001h (write cache) feature code 0002h (write cache

reordering), and feature code 0003h (time interval for temperature logging). It also supports D000h(Power Safe Write Cache capacitor test interval), (D001h(read/write power governor mode), D002h(read thermal governor mode), D003h(read power governor burst power), D004h(read power governor average power)

− Data table command - DC S3500 Series supports data table command as specified in ATA8-ACS2. This will read out temperature logging information in table ID 0002h

− Read Status Support - DC S3500 Series supports read status log − SCT command 0xD801with State=0, Option=1, ID Word 106 can be used to change from 0x6003 to 0x4000

(4KB physical sector size to 512B physical sector size support change).

5.7 Data Set Management Command Set

Intel SSD DC S3500 Series supports the Data Set Management command set Trim attribute, which consists of:

− DATA SET MANAGEMENT

5.8 Host Protected Area Command Set

Intel SSD DC S3500 Series supports the Host Protected Area command set, which consists of:

− READ NATIVE MAX ADDRESS − SET MAX ADDRESS − READ NATIVE MAX ADDRESS EXT − SET MAX ADDRESS EXT

Intel SSD DC S3500 Series also supports the following optional commands:

− SET MAX SET PASSWORD − SET MAX LOCK − SET MAX FREEZE LOCK − SET MAX UNLOCK

5.9 48-Bit Address Command Set

Intel® SSD DC S3500 Series supports the 48-bit Address command set, which consists of:

− FLUSH CACHE EXT − READ DMA EXT − READ NATIVE MAX ADDRESS EXT − READ SECTOR(S) EXT − READ VERIFY SECTOR(S) EXT − SET MAX ADDRESS EXT − WRITE DMA EXT − WRITE MULTIPLE EXT − WRITE SECTOR(S) EXT − WRITE MULTIPLE FUA EXT − WRITE DMA FUA EXT

Product Specification January 2015 28 328860-008US

Page 29: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

5.10 General Purpose Log Command Set

Intel SSD DC S3500 Series supports the General Purpose Log command set, which consists of:

− READ LOG EXT − WRITE LOG EXT

5.11 Native Command Queuing

Intel SSD DC S3500 Series supports the Native Command Queuing (NCQ) command set, which includes:

− READ FPDMA QUEUED − WRITE FPDMA QUEUED

Note: With a maximum Queue Depth set to 32.

5.12 Software Settings Preservation

Intel SSD DC S3500 Series supports the SET FEATURES parameter to enable/disable the preservation of software settings.

January 2015 Product Specification 328860-008US 29

Page 30: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

6.0 Certifications and Declarations This table describes the Device Certifications supported by the Intel® SSD DC S3500 Series.

Table 21: Device Certifications and Declarations

Certification Description

CE Compliant Low Voltage DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006, and EMC Directive 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004.

UL Recognized

Underwriters Laboratories, Inc. Bi-National Component Recognition; UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

C-Tick Compliant Compliance with the Australia/New Zealand Standard AS/NZS3548 and Electromagnetic Compatibility (EMC) Framework requirements of the Australian Communication Authority (ACA).

BSMI Compliant Compliance to the Taiwan EMC standard CNS 13438: Information technology equipment - Radio disturbance Characteristics - limits and methods of measurement, as amended on June 1, 2006, is harmonized with CISPR 22: 2005.04.

KCC Compliance with paragraph 1 of Article 11 of the Electromagnetic Compatibility Control Regulation and meets the Electromagnetic Compatibility (EMC) Framework requirements of the Radio Research Laboratory (RRL) Ministry of Information and Communication Republic of Korea.

VCCI Voluntary Control Council for Interface to cope with disturbance problems caused by personal computers or facsimile.

RoHS Compliant Restriction of Hazardous Substance Directive

WEEE Directive on Waste Electrical and Electronic Equipment

Product Specification January 2015 30 328860-008US

Page 31: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

7.0 References

This table identifies the Standards information referenced in this document.

Table 22: Standards References

Date Title Location

July 2012 Solid-State Drive (SSD) Requirements and Endurance Test Method (JESD219)

http://www.jedec.org/standards-documents/results/jesd219

Sept 2010 Solid-State Drive (SSD) Requirements and Endurance Test Method (JESD218)

http://www.jedec.org/standards-documents/docs/jesd218/

Dec 2008 VCCI http://www.vcci.jp/vcci_e/

June 2009 RoHS http://qdms.intel.com/ Click Search MDDS Database and search for material description datasheet

August 2009 ACS-2-ATA/ATAPI Command Set 2 Specification http://www.t13.org/

June 2009 Serial ATA Revision 3.0 http://www.sata-io.org/

May 2006 SFF-8223, 2.5-inch Drive w/Serial Attachment Connector

http://www.sffcommittee.org/

May 2005 SFF-8201, 2.5-inch drive form factor http://www.sffcommittee.org/

1995 1996 1995 1995 1997 1994

International Electrotechnical Commission EN 61000 4-2 (Electrostatic discharge immunity test) 4-3 (Radiated, radio-frequency, electromagnetic field immunity test) 4-4 (Electrical fast transient/burst immunity test) 4-5 (Surge immunity test) 4-6 (Immunity to conducted disturbances, induced by radio- frequency fields) 4-11 (Voltage Variations, voltage dips, short interruptions and voltage variations immunity tests)

http://www.iec.ch/

1995 ENV 50204 (Radiated electromagnetic field from digital radio telephones)

http://www.dbicorporation.com/radimmun.htm/

January 2015 Product Specification 328860-008US 31

Page 32: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Appendix A: IDENTIFY DEVICE Command Data Table 23: Returned Sector Data

Word F = Fixed

V = Variable X = Both

Default Value Description

0 X 0040h General configuration bit-significant information

1 X 3FFFh Obsolete - Number of logical cylinders (16,383)

2 V C837h Specific configuration

3 X 0010h Obsolete - Number of logical heads (16)

4-5 X 0h Retired

6 X 003Fh Obsolete - Number of logical sectors per logical track (63)

7-8 V 0h Reserved for assignment by the CompactFlash* Association (CFA)

9 X 0h Retired

10-19 F varies Serial number (20 ASCII characters)

20-21 X 0h Retired

22 X 0h Obsolete

23-26 F varies Firmware revision (8 ASCII characters)

27-46 F varies Model number (Intel® Solid-State Drive)

47 F 8001h 7:0—Maximum number of sectors transferred per interrupt on multiple commands

48 F 4000h Trusted Computing Feature Set

49 F 2F00h Capabilities

50 F 4000h Capabilities

51-52 X 0h Obsolete

53 F 0007h Words 88 and 70:64 valid

54 X 3FFFh Obsolete - Number of logical cylinders (16,383)

55 X 0010h Obsolete - Number of logical heads (16)

56 X 003Fh Obsolete - Number of logical sectors per logical track (63)

57-58 X FC1000FBh Obsolete

59 F BF01 Number of sectors transferred per interrupt on multiple commands

60-61 V

80GB: 0950F8B0h 120GB: 0DF94BB0h 160GB: 0FFFFFFFh 240GB: 0FFFFFFFh 300GB: 0FFFFFFFh 400GB: 0FFFFFFFh 480GB: 0FFFFFFFh 600GB: 0FFFFFFFh 800GB: 0FFFFFFFh

Total number of user-addressable sector for 28-bit commands

62 X 0h Obsolete

63 X 0007h Multi-word DMA modes supported/selected

64 F 0003h PIO modes supported

65 F 0078h Minimum multiword DMA transfer cycle time per word

66 F 0078h Manufacturer’s recommended multiword DMA transfer cycle time

67 F 0078h Minimum PIO transfer cycle time without flow control

68 F 0078h Minimum PIO transfer cycle time with IORDY flow control

69 F 4030h Additional Supported

Product Specification January 2015 32 328860-008US

Page 33: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Word F = Fixed

V = Variable X = Both

Default Value Description

70 F 0000h Reserved

71-74 F 0h Reserved for IDENTIFY PACKET DEVICE command

75 F 001Fh Queue depth

76 F 850Eh Serial ATA capabilities

77 F 0006h Reserved for future Serial ATA definition

78 F 0040h Serial ATA features supported

79 V 0040h Serial ATA features enabled

80 F 03FCh Major version number

81 F 0110h Minor version number

82 F 746Bh Command set supported

83 F 7501h Command sets supported

84 F 6163h Command set/feature supported extension

85 X 7469h Command set/feature enabled

86 X B401h Command set/feature enabled

87 X 6163h Command set/feature default

88 X 407Fh Ultra DMA Modes

89 F 0002h Time required for security erase unit completion

90 F 0002h Time required for enhanced security erase completion

91 V 0h Current advanced power management value

92 V 0FFFEh Master Password Revision Code

93 X 0h Hardware reset result: the contents of bits (12:0) of this word shall change only during the execution of a hardware reset

94 V 0h Vendor’s recommended and actual acoustic management value

95 F 0h Stream minimum request size

96 V 0h Streaming transfer time - DMA

97 V 0h Streaming access latency - DMA and PIO

98-99 F 0h Streaming performance granularity

100-103 V

80GB: 0950F8B0h 120GB: 0DF94BB0h 160GB: 12A19EB0h 240GB: 1BF244B0h 300GB: 22EEC130h 400GB: 2E9390B0h 480GB: 37E436B0h 600GB: 45DD2FB0h 800GB: 5D26CEB0h

Maximum user LBA for 48-bit address feature set

104 V 0h Streaming transfer time - PIO

105 V 0004h Maximum number of 512-byte blocks of LBA Range Entries per DATA SET MANAGEMENT command

106 F 6003h Default Physical sector size / logical sector size. Can be changed to 0004h to reflect 512Bytes/Sector

107 F 0h Inter-seek delay for ISO-7779 acoustic testing in microseconds

108-111 F varies Unique ID

112-115 F 0h Reserved for world wide name extension to 128 bits

116 V 0h Reserved for technical report

117-118 F 0h Words per logical sector

119 F 405Ch Supported settings

120 X 401Ch Command set/feature enabled/supported

January 2015 Product Specification 328860-008US 33

Page 34: Intel Solid-State Drive DC S3500 Series Product Specification · Intel® Solid-State Drive DC S3500 Series Contents Revision History

Intel® Solid-State Drive DC S3500 Series

Word F = Fixed

V = Variable X = Both

Default Value Description

121-126 F 0h Reserved

127 X 0h Removable Media Status Notification feature set support

128 X 0021h Security status

129 V 001Ch Vendor-specific

130-139 X 0h Vendor-specific

140-149 X 0h Disable Logical Error Field

150-159 X 0h Vendor-specific

160 X 0h CompactFlash Association (CFA) power mode 1

161-167 X 0h Reserved for assignment by the CFA

168 X 0003h Reserved for assignment by the CFA

169 X 0001h Data set management Trim attribute support

170-175 F 0h Reserved for assignment by the CFA

176-205 V Varies Current media serial number

206 X 003Dh SCT Command Transport

207-208 F 0000h Reserved

209 X 4000h Alignment of logical blocks within a physical block

210-211 V 0000h Write-Read-Verify Sector Count Mode 3 (DWord)

212-213 F 0000h Write-Read-Verify Sector Count Mode 2 (DWord)

214 X 0000h NV Cache Capabilities

215-216 V 0000h NV Cache Size in Logical Blocks (DWord)

217 F 0001h Nominal media rotation rate

218 V 0000h Reserved

219 F 0000h NV Cache Options

220 V 0000h Write-Read-Verify feature set

221 X 0000h Reserved

222 F 101Fh Transport major version number

223 F 0000h Transport minor version number

224-229 F 0000h Reserved

230-233 X 0000h Extended Number of User Addressable Sectors (QWord)

234 F 0001h Minimum number of 512-byte data blocks per DOWNLOAD MICROCODE command for mode 03h

235 F FFFFh Maximum number of 512-byte data blocks per DOWNLOAD MICROCODE command for mode 03h

236-254 X 0000h Reserved

255 V Varies Integrity word

Notes: F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when media is removed

or changed. V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the commands executed

by the device. X = F or V. The content of the word may be fixed or variable.

Product Specification January 2015 34 328860-008US