international journal of scientific research and reviews · 2018-05-17 · watercontent in the soil...

15
Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471 IJSRR, 7(1) Special Jan. – March, 2018 Page 457 Research article Available online www.ijsrr.org ISSN: 2279–0543 International Journal of Scientific Research and Reviews Variation of Electrical Parameters of Soil With Moisture and Salinity over Frequency Range From 20 HZ TO 2 MHZ Virendrakumar N. Patel 1 , Prahalad D. Chaudhary 2 , Hemal P.Vankar 3 ,Vipin A. Rana 4 , Amardatta D. Vyas 5 and DeepakH. Gadani 6* 1-6 Dept. of Physics, University School of Sciences, Gujarat University, Ahmedabad 380 009, India E-mail: [email protected] 1 , [email protected] 6* ABSTRACT Measurements of electrical properties like dielectric constant, dielectric loss, conductivity, tanδ, electric modulus (M * )and complex impedance (Z * )for various moisture contents and saline contents of soilhave been carried out usingPrecision LCR meter(Agilent make E-4980A)operating in the frequency range from 20 Hz to 2 MHz.Measurements were carried out by adding (i) double distilled water and (ii) saline water of 20,000 ppm, in various proportions, inPalanpur district sandy soil.It has been observed that dielectric constantє’ and dielectric lossє” increase with increase in the moisture contents in the soil over the frequency range from 20 Hz to 2 MHz. The value of tanδ peak and conductivity increase with increase in moisture in the soil. The variation oftanδ and conductivity with frequencyhave also been discussed. The electric modulus values M’ and M” are found to increase with increase in frequency, but decrease with increase in water content and saline watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted over the given frequency range, for various moisture, and saline moisture and analysed. The Z” minimum values separating the bulk material and electrode polarization are observed to decrease towards lower frequencies with increase in water contents in the soil. KEYWORD Complex Dielectric Constant,Soil, Moisture content, Saline content, Precision LCR meter * Corresponding Address: Dr. Deepak H Gadani, Associate Professor,Department of Physics, University School of Sciences, Gujarat University,Ahmedabad 380 009, E-mail:[email protected], Mo. No.: 9879005755

Upload: others

Post on 06-Apr-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 457

Research article Available online www.ijsrr.org ISSN: 2279–0543

International Journal of Scientific Research and Reviews

Variation of Electrical Parameters of Soil With Moisture and Salinity over Frequency Range From 20 HZ TO 2 MHZ

Virendrakumar N. Patel1, Prahalad D. Chaudhary2, Hemal P.Vankar3,Vipin A.

Rana4, Amardatta D. Vyas5 and DeepakH. Gadani6*

1-6Dept. of Physics, University School of Sciences, Gujarat University, Ahmedabad 380 009, India E-mail: [email protected], [email protected]*

ABSTRACT Measurements of electrical properties like dielectric constant, dielectric loss, conductivity,

tanδ, electric modulus (M*)and complex impedance (Z*)for various moisture contents and saline contents of soilhave been carried out usingPrecision LCR meter(Agilent make E-4980A)operating in the frequency range from 20 Hz to 2 MHz.Measurements were carried out by adding (i) double distilled water and (ii) saline water of 20,000 ppm, in various proportions, inPalanpur district sandy soil.It has been observed that dielectric constantє’ and dielectric lossє” increase with increase in the moisture contents in the soil over the frequency range from 20 Hz to 2 MHz.The value of tanδ peak and conductivity increase with increase in moisture in the soil. The variation oftanδ and conductivity with frequencyhave also been discussed. The electric modulus values M’ and M” are found to increase with increase in frequency, but decrease with increase in water content and saline watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted over the given frequency range, for various moisture, and saline moisture and analysed. The Z” minimum values separating the bulk material and electrode polarization are observed to decrease towards lower frequencies with increase in water contents in the soil.

KEYWORD Complex Dielectric Constant,Soil, Moisture content, Saline content, Precision LCR meter

*Corresponding Address:

Dr. Deepak H Gadani, Associate Professor,Department of Physics,

University School of Sciences, Gujarat University,Ahmedabad 380 009,

E-mail:[email protected], Mo. No.: 9879005755

Page 2: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 458

INTRODUCTION Moisture plays and important role in soil which affects land fertility, growth and yield. The

electrical properties provide very useful information for agriculture, meteorology, hydrology and

other application1. Mainly, dielectric permittivity is very strong function of volumetric soils

moisture. Curtis have been measured moisture effects on dielectric properties of soils at 100 MHz2.

Complex permittivity of moist soil over 10 Hz to 5 MHz frequency range was measured by

Bobrov et al3 using LCR meter.The electrical properties of Palanpur district sandy soil with fertilizer

for various concentration over 20 Hz to 2 MHz frequency range was measured by Gadani et al4. It

has been observed that the complex permittivity decreases with increase in frequency from 10kHz to

2 MHzrange.

MATERIALS AND METHOD

(I) Sample preparation The soil sample was collected from the Palanpur district. Stones and gravels were removed

from the soil sample and then soil sample was oven dried.The texture structure of Palanpur district

soil shows 82% sand, 16% silt, 1% clay content which belongs to sandy soil. The dry density of the

soil is 1.59 g/cm3. The wilting point (WP) and transition moisture (Wt) have been calculated using

the Wang and Schmugge Model6 as

WP = 0.067740̶.00064 × Sand + 0.00478 × Clay . . . (1)

Wt = 0.49 × WP + 0.165 . . . (2)

Where, Sand and clay stand for the sand and clay contents in percent of dry weight of the soil.

(II) Preparation of soil sample for various moisture contents Distilled water wasadded to the soil in different proportions and allowed to saturate for 24hrs.

Gravimetric moisture and volumetric moisture content were calculated using,

Wm = ̶

. . . (3)

Hence, the volumetric moisture content was determined as

Wv = Wm × ρb. . . (4)

Where, ρb= dry bulk density of the soil.

Page 3: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 459

(III) Preparation of soil sample for various saline water contents The saline water solution of 20000 PPM was prepared by adding 20 gm NaCl (AR grade) in

the 1 litre distilled water. Saline water was added to the soil in different proportions and then allowed

to saturate for 24hrs.The gravimetric moisture and volumetric moisture content in the soil sample

were calculated using Eqs.(3) and (4), respectively.

(IV) Experimental set up and Measurement Experimental setup and methodology as discussed by Gadani et al4 has been followed to

obtain electrical properties.

A precision LCR meter (Agilent make E-4980A) was used for the measurements in the frequency

range from 20 Hz to 2 MHz. A standard four terminal probe (Agilent 16089A) with Kelvin clip leads

was connected to the LCR meter.The open and short circuit compensation of the coaxial capacitor

was carried out to eliminate the effect of stray capacitance during the evaluation of frequency

dependant values of complex dielectric constant. The coaxial capacitor was calibrated using liquids

of known dielectric constant, like carbon tetrachloride, benzene and 1-propanol (AR grad) as

represented by Gadani et al4.

The dielectric constant of each sample was calculated using

Є’ = 2.1012 (CP-CO) + 1.0177 … (5)

RESULTS AND DISCUSSION

Dielectric behaviour of sample: The variation of dielectric constant and dielectric loss of Palanpur sandy soil with different

proportions of moisture contents over the frequency range from 20 Hz to 2 MHz is shown in Fig. (1).

Page 4: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 460

Fig. 1- Measured values of (a) dielectric constant and (b) dielectric loss of Palanpur districtsandy soil for various

moisture contents in the soil with frequency.

It can be observed from Fig.(1) that the dielectric constant and dielectric loss of the moist soil

decrease with increase in frequency from 20 Hz to 2 MHz.For dryer soil (Wv = 0.00073 cm3/cm3),

1.0E+00

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+06

1.0E+07

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Die

lect

ric C

onst

ant

Frequency (Hz)

Dielectric constant vs. Frequency 0.00073

0.0182

0.038347826

0.059513043

0.11550303

0.182438462

0.193584127

0.271111111

0.313956

0.321261538

1.0E+00

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+06

1.0E+07

1.0E+08

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Die

lect

ric l

oss

Frequency (Hz)

Dielectric loss vs. Frequency 0.00073

0.0182

0.038347826

0.059513043

0.11550303

0.182438462

0.193584127

0.271111111

0.313956

0.321261538

Page 5: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 461

the dielectric constant and dielectric loss values are small compared to moist soil and decrease

slowly with increase in frequency.

The variation in the values of dielectric constant and dielectric loss with frequency for

different the saline water content is shown in Fig. (2).

Fig. 2- Measured values of (a) dielectric constant and (b) dielectric loss of Palanpur district sandy soil for various

saline water contents in the soil with frequency.

1.0E+00

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+06

1.0E+07

1.0E+08

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Die

lect

ric

cons

tant

Frequency (Hz)

Dielectric constant vs. Frequency0.00073

0.030151515

0.0388

0.067216279

0.088376471

0.105104348

0.132679545

0.143345652

1.0E+00

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+06

1.0E+07

1.0E+08

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Die

lect

ric

loss

Frequency (Hz)

Dielectric loss vs. Frequency 0.00073

0.030151515

0.0388

0.067216279

0.088376471

0.105104348

0.132679545

0.143345652

Page 6: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 462

The dielectric constant and dielectric loss of soil with the saline water content soil decreases

with increase infrequency.

The enhancement in dielectric constant and dielectric loss values of wet soil is due to electro

chemical polarization7. This arises due to increase in surface charge carrier density in the presence of

water molecules in the pore spaces of sandy soil.The logarithmic slope of frequency dependent ϵ’

value of wet soil is close to -1 for the frequency below ~ 100 kHz, which indicates the leakiness of

the EDL capacitances (blocking layers) to moving charges. Above 100 kHz, the slope decreases from

-1, but does not approach 0. The decrease in slope of frequency dependent ϵ’ values for wet soil,

suggests decrease in charge movement through the layers.

Fig.3- Measured values of (a) dielectric constant and (b) dielectric loss of Palanpur district sandy soil with

Volumetric moisture content.

The measured value of the dielectric constant and dielectric loss of the moist soil and saline

water content soil sample at 2 MHz frerquency has also been plotted agaist volumetric moisture in

cm3 cm-3as shown in Fig.(3).It is observed that the dielectric constant and dielectric loss increase

with increase in the moisture content in the soil. Further, dielectric loss increase slowly up to the

transition moisture, after which it increases rapidly, but the dielectric constant increases slowly with

volumetric moisture content Wv.

0.0E+00

5.0E+01

1.0E+02

1.5E+02

2.0E+02

2.5E+02

0 0.1 0.2 0.3 0.4

Com

plex

Per

mitt

ivity

Volumetric moisture content (cm3cm-3)

Complex Permittivity vs Volumetric moisture content for moisture

content

є'є''actualPoly. (є')Poly. (є''actual)

0.0E+00

2.0E+02

4.0E+02

6.0E+02

8.0E+02

1.0E+03

1.2E+03

1.4E+03

1.6E+03

1.8E+03

0 0.05 0.1 0.15 0.2

Com

plex

Per

mitt

ivity

Volumetric moisture content (cm3cm-3)

Complex Permittivity vs. Volumetric moisture content for saline water

content

є'є''actualPoly. (є')Poly. (є''actual)

Page 7: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 463

It can be seen from these plots that at 2 MHz measurement and moisture content in the soil, the

dielectric loss values follow the trend as;

Є”20,000 ppm > Є”doble distilled water

Conductivity:

Fig.4 (a) Real (b) Imaginary values of Conductivity for variation with Frequency for various moisture content in

the soil

0

0.005

0.01

0.015

0.02

0.025

0.03

0.035

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Rea

l Con

duct

ivity

σ'(

S/m

)

Frequency (Hz)

Real Conductivity σ' vs Frequency for Moisture content0.000730.01820.0383478260.0595130430.115503030.1824384620.1935841270.2711111110.3139560.321261538

0

0.001

0.002

0.003

0.004

0.005

0.006

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Imag

inar

y C

ondu

ctiv

ity σ

'' (S

/m)

Frequency (Hz)

Imaginary Conductivity σ'' vs Frequency for Moisture0.00073

0.0182

0.038347826

0.059513043

0.11550303

0.182438462

0.193584127

0.271111111

0.313956

0.321261538

Page 8: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 464

Fig.5 (a) Real (b) Imaginary values of Conductivity for variation with Frequency for various saline water content

in the soil

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

0.18

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Rea

l Con

duct

ivity

σ'(

S/m

)

Frequency (Hz)

Real Conductivity σ' vs Frequency for Saline 0.00073

0.030151515

0.0388

0.067216279

0.088376471

0.105104348

0.132679545

0.143345652

0

0.005

0.01

0.015

0.02

0.025

0.03

0.035

0.04

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

Imag

inar

y C

ondu

ctiv

ity σ

" (S

/m)

Frequency (Hz)

Imaginary Conductivty σ'' vs Frequency for Saline 0.00073

0.030151515

0.0388

0.067216279

0.088376471

0.105104348

0.132679545

0.143345652

Page 9: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 465

The variation of realconductivity for various proportions distilled water and saline water

content (20,000 ppm) in the soil with frequency is shown in Fig.(4)& Fig.(5). It has been observed

that the conductiviy increase with increase in frequncy from 20 Hz to 2 MHz and also increase with

the moisture content in the soil. It has been observed that the conductivity of the soil is small for

lower frequency and increase with increase in frequency and also increase with increase in moisture

content, Similar observation were observed by other researchersGadani et al4,Sengwa et a8,9,

levitskaya and sternberg10, Bobrove et al3.

tanδ:

Fig.6 Calculated values of tan δ of Palanpur district sandy soil for various moisture content and saline water

content with frequency

0

5

10

15

20

25

30

35

40

45

50

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

tan

δ

Frequency (Hz)

tan δ vs Frequency for moisture content0.000730.01820.0383478260.0595130430.115503030.1824384620.1935841270.2711111110.3139560.321261538

0

5

10

15

20

25

30

35

40

45

50

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

tan

δ

Frequency (Hz)

tan δ vs Frequency for saline water content

0.00073

0.030151515

0.0388

0.067216279

0.088376471

0.105104348

0.132679545

0.143345652

Page 10: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 466

The variation of tan δ of the Palanpur sandy soil for various moisture content and saline content in

the frequency range from 20 Hz to 2MHz is shown in Fig.(6). It has been observed that the tan δ

peak value increases with increase in the moisture in the soil.

The frequency dependant tan δ peak values of the soil for different moisture and saline water content

has peak corrospond to the electro polarization frequency13. The value of relaxation frequency

separates the bulk material and the electro surface polarization phenomena in the low frequency

dielectric dispersion11.

Complex impedance:

Fig.8 Plot of Z” against Z’ for various moisture content in the Palanpur district sandy soil

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+02 1.0E+03 1.0E+04 1.0E+05

Z"

(Ω)

Z' (Ω)

Z" vs Z' for Moisture

0.0182 0.038347826 0.059513043 0.11550303 0.182438462

0.193584127 0.271111111 0.313956 0.321261538

Page 11: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 467

Fig.9Plot of Z” against Z’ for various saline water content in the Palanpur district sandy soil

The plot of Z” against Z’ over the given frequency range, moisture and saline moisture

contents in the soil have been plotted in Fig.(8) and Fig.(9). The value of the experimental points

going from right to left side on the complex impedance plane plot of Palanpur sandy soil. The Z”

minimum values shift from right to left side with increase in moisture and saline content which

represents that the conductivity increases with increase in moisture contents in the soil. For saline

soil, the Z” decrease more rapidly with increase in moisture content due to additional conductivity by

the presence of sodium salts. For pure water as moisture content, the complex impedance Z” vs. Z’

has two arcs. It is seperated by some minimum value of Z”. The arc on the left side of Z”min

corrosponds to the bulk material effect and right side of Z”min corrosponds to the elecrode surface

polarization.

1.0E+00

1.0E+01

1.0E+02

1.0E+03

1.0E+04

1.0E+02 1.0E+03 1.0E+04 1.0E+05

Z" (Ω

)

Z' (Ω)

Z" vs Z' for Saline

0.030151515 0.0388 0.067216279

0.088376471 0.105104348 0.132679545

0.143345652

Page 12: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 468

Electric modulus:

Fig.10 Plot of M’ and M” against Frequency for various moisture content

1.0E-08

1.0E-07

1.0E-06

1.0E-05

1.0E-04

1.0E-03

1.0E-02

1.0E-01

1.0E+001.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

M'

Frequency

M' vs. Frequency for moisture

0.00073 0.0182 0.038347826 0.0595130430.11550303 0.182438462 0.193584127 0.2711111110.313956 0.321261538

1.0E-08

1.0E-07

1.0E-06

1.0E-05

1.0E-04

1.0E-03

1.0E-02

1.0E-01

1.0E+00

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

M"

Frequency

M" vs. Frequency for moisture

0.00073 0.0182 0.038347826 0.0595130430.11550303 0.182438462 0.193584127 0.2711111110.313956 0.321261538

Page 13: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 469

Fig.11 Plot of M’ and M” against Frequency for various saline water content

1.0E-09

1.0E-08

1.0E-07

1.0E-06

1.0E-05

1.0E-04

1.0E-03

1.0E-02

1.0E-011.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

M'

Frequency

M' vs. Frequency for saline

0.00073 0.030151515 0.0388

0.067216279 0.088376471 0.105104348

0.132679545 0.143345652

1.0E-08

1.0E-07

1.0E-06

1.0E-05

1.0E-04

1.0E-03

1.0E-02

1.0E-01

1.0E+01 1.0E+02 1.0E+03 1.0E+04 1.0E+05 1.0E+06 1.0E+07

M"

Frequency

M" vs. Frequency for saline

0.00073 0.030151515 0.0388

0.067216279 0.088376471 0.105104348

0.132679545 0.143345652

Page 14: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 470

The variation of the evaluated values of M’ and M” against frequency of soil with different

proportions. Is shown in Fig.(10) and Fig.(11) The value of M’ and M” decrease with increase in

moisture content but increase with increase in frequency.

CONCLUSION It has been observed that the complex permittivity increases with increase in moisture contents in the

soil but decreases with increase in frequency. Similar, behaviour of complex permittivity for saline

water content in the soil has been observed.

ACKNOWLEDGEMENT Authors are thankful to funding agencies DST, New Delhi and UGC, New Delhi for

providing financial assistance through DST-FIST (LEVEL-1) project (SR/FST/PSI-001/2006) and

DRS-SAP program grant [No.F.530/10/DRS/2010(SAP-1)] respectively, to develop experimental

facilities which was utilized to carry out this work, Authors are also thankful to Prof.P.N.Gajjar,

Head, Dept. of Physics, University School of Sciences, Gujarat University, Ahmedabad for his

constant encouragement and support.

REFERENCE 1. Gadani D. H. & Vyas A. D. Dielectric mixing model for the estimation of complex

permittivity of wet soils at C and X band microwave frequencies. Indian J. of Pure & Applied

Phys.2015; 53:190-198.

2. Curtis J. O. Moisture effects on the dielectric properties of soils. IEEE Trans Geosci Remote

Sensing. 2001; 39:125-128.

3. Bobrov P. P., Repin A. V. and Rodionova O. V. Wideband frequency domain method of soil

dielectric property measurements. IEEE Trans Geosci Remote Sensing. 2015; 53:2366-2372.

4. Gadani D. H., Vyas A. D. Rana V. A. Dielectric properties of wet and fertilized soils at radio

frequencies. Indian J. of Pure & Applied Phys. 2014; 52:399-410.

5. Wang J. R. &Schmugge T. J. An empirical model for the complex dielectric permittivity of

soils as a function of water content. IEEE Trans Geosci Remote Sens. 1980; 18(4):288-295.

6. Sengwa R. J.&Soni A. Low-frequency dielectric dispersion and microwave dielectric

properties of dry and water-saturated limestones of Jodhpur region. Geophysics. 2006;

71(5):269-277

7. Sengwa R. J., Soni A. & Ram B. Dielectric behaviour of shale and calcareous sandstone of

Jodhpur region. Indian J. Radio & Space Phys. 2004; 33:329-335.

Page 15: International Journal of Scientific Research and Reviews · 2018-05-17 · watercontent in the soil at given frequency. The complex impedance plane plots (Z”, Z’) have been plotted

Gadani Deepak H. et al., IJSRR 2018, 7(1) Suppl., 457-471

IJSRR, 7(1) Special Jan. – March, 2018 Page 471

8. Sengwa R. J., Choudhary S &Sankhla S. Low frequency dielectric relaxation processes and

ionic conductivity of montmorillonite clay nanoparticles colloidal suspension in

poly(vinylpyrrolidone)-ethylene glycol blends. eXPRESS Polymer Lett. 2008; 2(11):800-

809.

9. Sternberg B.K. &Levitskaya T.M. Electrical parameters of soils in the frequency range from

1 kHz to 1 GHz, using lumped-circuit methods. Radio Science. 2001; 36:709-719.

10. Sengwa R. J., Choudhary S &Sankhla S. Dielectric spectroscopy of hydrophilic polymers-

montmorillonite clay nanocomposite aqueous colloidal suspension. Colloids and Surfaces A:

Physiochemical and engineering aspects. Elsevier.2009; 336:79-87.