RUGGEDCOM Modules

Catalog

For MX5000RE

06/2018RC1333-EN-03

Preface

Introduction 1

Power Supply Modules 2

Copper Ethernet Modules 3Fiber Optic EthernetModules 4

Serial Modules 5

Control Modules 6

Switch Modules 7Network RedundancyModules 8

Blank Modules 9

RUGGEDCOM ModulesCatalog

ii

Copyright © 2018 Siemens Canada LtdAll rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorizedexcept where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application ortrademark registration.This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may bephotocopied, reproduced or translated to another language without the prior written consent of Siemens Canada Ltd.

Disclaimer Of LiabilitySiemens has verified the contents of this document against the hardware and/or software described. However, deviations between the productand the documentation may exist.Siemens shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing,performance, or use of this material.The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. Weappreciate any suggested improvements. We reserve the right to make technical improvements without notice.

Registered TrademarksRUGGEDCOM™ and ROS™ are trademarks of Siemens Canada Ltd.Linux® is the registered trademark of Linus Torvalds in the United States and other countries.The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on aworld-wide basis.Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of theowner.

Security InformationSiemens provides products and solutions with industrial security functions that support the secure operation of plants, machines, equipmentand/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutionsundergo continuous development. Siemens recommends strongly that you regularly check for product updates.For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) andintegrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also beconsidered. For more information about industrial security, visit https://www.siemens.com/industrialsecurity.To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit https://support.automation.siemens.com.

WarrantyFor warranty details, visit https://www.siemens.com/ruggedcom or contact a Siemens customer service representative.

Contacting SiemensAddressSiemens Canada LtdIndustry Sector300 Applewood CrescentConcord, OntarioCanada, L4K 5C7

TelephoneToll-free: 1 888 264 0006Tel: +1 905 856 5288Fax: +1 905 856 1995

[email protected]://www.siemens.com/ruggedcom

RUGGEDCOM ModulesCatalog

Table of Contents

iii

Table of ContentsPreface ............................................................................................................. v

Alerts .................................................................................................................................................. vRelated Documents ............................................................................................................................. viTraining .............................................................................................................................................. viCustomer Support ............................................................................................................................... viOrdering RUGGEDCOM Products .......................................................................................................... vii

Chapter 1Introduction ..................................................................................................... 1

1.1 Available Modules ......................................................................................................................... 21.2 Installing/Removing Modules ......................................................................................................... 61.3 Dimensions .................................................................................................................................. 7

Chapter 2Power Supply Modules ..................................................................................... 9

2.1 RUGGEDCOM MX5000REPN PS MHIF ............................................................................................ 10

Chapter 3Copper Ethernet Modules ................................................................................ 11

3.1 RUGGEDCOM MX5000REPN LM M4CG02 ...................................................................................... 123.2 RUGGEDCOM MX5000REPN LM M8TX02 ...................................................................................... 143.3 RUGGEDCOM MX5000REPN LM M12TX01 .................................................................................... 16

Chapter 4Fiber Optic Ethernet Modules .......................................................................... 19

4.1 RUGGEDCOM MX5000REPN LM M4FG01 ...................................................................................... 204.2 RUGGEDCOM MX5000REPN LM M4FG03 ...................................................................................... 224.3 RUGGEDCOM MX5000REPN LM M4FX11 ...................................................................................... 244.4 RUGGEDCOM MX5000REPN LM M8FX11 ...................................................................................... 26

Chapter 5Serial Modules ................................................................................................ 29

5.1 RUGGEDCOM MX5000REPN LM MS01 .......................................................................................... 30

Table of Contents

RUGGEDCOM ModulesCatalog

iv

Chapter 6Control Modules ............................................................................................. 33

6.1 RUGGEDCOM MX5000REPN MCM01 L3SEL3HW ............................................................................ 346.2 RUGGEDCOM MX5000REPN CM01 L3SECL3HW ............................................................................. 35

Chapter 7Switch Modules .............................................................................................. 37

7.1 RUGGEDCOM MX5000REPN MSM36 ............................................................................................. 387.2 RUGGEDCOM MX5000REPN SM MSM61 ....................................................................................... 407.3 RUGGEDCOM MX5000REPN SM MSM70 ....................................................................................... 41

Chapter 8Network Redundancy Modules ........................................................................ 43

8.1 RUGGEDCOM MX5000REPN LM MPRP ........................................................................................... 44

Chapter 9Blank Modules ................................................................................................ 47

9.1 RUGGEDCOM MX5000REPN PS XX ............................................................................................... 489.2 RUGGEDCOM MX5000REPN LM XX .............................................................................................. 49

RUGGEDCOM ModulesCatalog

Preface

Alerts v

PrefaceThis document details RUGGEDCOM power and line modules available for use with devices in the RUGGEDCOMMX5000RE series of multi-service routers and switches.It is intended for use by network technical support personnel responsible for the installation, commissioning andmaintenance of routers and switches. It is also recommended for use by network and system planners, systemprogrammers, and line technicians.

CONTENTS• “Alerts”• “Related Documents”• “Training”• “Customer Support”• “Ordering RUGGEDCOM Products”

AlertsThe following types of alerts are used when necessary to highlight important information.

DANGER!DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death orserious injury.

WARNING!WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/orequipment damage.

CAUTION!CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage.

IMPORTANT!IMPORTANT alerts provide important information that should be known before performing a procedureor step, or using a feature.

NOTENOTE alerts provide additional information, such as facts, tips and details.

Preface

RUGGEDCOM ModulesCatalog

vi Related Documents

Related DocumentsOther documents that may be of interest include:• RUGGEDCOM MX5000RE Installation Guide

https://support.industry.siemens.com/cs/ca/en/view/88894895

TrainingSiemens offers a wide range of educational services ranging from in-house training of standard courses onnetworking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs,experience and application.Siemens' Educational Services team thrives on providing our customers with the essential practical skills to makesure users have the right knowledge and expertise to understand the various technologies associated with criticalcommunications network infrastructure technologies.Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility,transportation and industrial markets, allows Siemens to provide training specific to the customer's application.For more information about training services and course availability, visit https://www.siemens.com/ruggedcom orcontact a Siemens Sales representative.

Customer SupportCustomer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or generalinformation, contact Siemens Customer Support through any of the following methods:

OnlineVisit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or checkon the status of an existing SR.

TelephoneCall a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit http://www.automation.siemens.com/mcms/aspa-db/en/automation-technology/Pages/default.aspx.

Mobile AppInstall the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobiledevice and be able to:• Access Siemens' extensive library of support documentation, including FAQs and manuals• Submit SRs or check on the status of an existing SR• Contact a local Siemens representative from Sales, Technical Support, Training, etc.• Ask questions or share knowledge with fellow Siemens customers and the support community

RUGGEDCOM ModulesCatalog

Preface

Ordering RUGGEDCOM Products vii

Ordering RUGGEDCOM ProductsUse the RUGGEDCOM-Selector to select and configure RUGGEDCOM products and accessories. Once selected, anitem(s) can be transferred to the Siemens Industry Mall and ordered.

RUGGEDCOM-Selectorhttp://www.siemens.com/ruggedcom-selector.

For more information, refer to https://www.siemens.com/ruggedcom.

Preface

RUGGEDCOM ModulesCatalog

viii Ordering RUGGEDCOM Products

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

1

IntroductionThis catalog details the various power and line modules available for the RUGGEDCOM MX5000RE. Modules allownetwork designers to quickly and cost effectively adjust their communications infrastructure to the needs of thefacilities and the network.It is intended to be used as a supplement to the Installation Guide for the device:• RUGGEDCOM MX5000RE Installation Guide

https://support.industry.siemens.com/cs/ww/en/view/88894895

IMPORTANT!Only qualified personnel should be allowed to install and work on this equipment. Qualified personsin the sense of the safety-related notices in this manual are defined as persons who are authorized tocommission, to ground, and to tag circuits, equipment, and systems in accordance with establishedsafety practices and standards.

CONTENTS• Section 1.1, “Available Modules”• Section 1.2, “Installing/Removing Modules”• Section 1.3, “Dimensions”

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

2 Available Modules

Section 1.1

Available ModulesThe following is a list of all power and line modules available for use in the RUGGEDCOM MX5000RE.

NOTEAll modules are conformal coated.

Power Supply ModulesRUGGEDCOM MX5000REPN PS MHIF Specifications

Input Range: 88 to 300 VDC or85 to 264 VACTerminal Type: Terminal locatedon chassis

Article Numbers6GK6050-0RL16-0AA1

Copper Ethernet ModulesRUGGEDCOM MX5000REPN LM M4CG02 Specifications

Ports: 4Speed: 1000 MbpsInterface: TXConnector: Micro-D

Article Numbers6GK6050-0ML20-0FD1 (Module)6GK6050-0RL20-0FD1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-4RD0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN LM M8TX02 SpecificationsPorts: 8Speed: 100 MbpsInterface: TXConnector: Micro-D

Article Numbers6GK6050-0ML20-0ND1 (Module)6GK6050-0RL20-0ND1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-8RD0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN LM M12TX01 SpecificationsPorts: 12Speed: 100 MbpsInterface: TXConnector: RJ45

Article Numbers6GK6050-0ML20-0NB1 (Module)6GK6050-0RL20-0NE1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-6RR0 (PatchPanel and Cables)

Fiber Optic Ethernet ModulesRUGGEDCOM MX5000REPN LM M8FX11 Specifications

Mode: MMSpeed: 100 MbpsInterface: FXPorts: 8Connector: LC

Article Numbers6GK6050-0ML20-0BD1 (Module)6GK6050-0RL20-0BD1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-8MM0 (PatchPanel and Cables)

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Available Modules 3

Distance: 2 km (1.2 mi)

RUGGEDCOM MX5000REPN LM M4FX11 SpecificationsMode: MMSpeed: 100 MbpsInterface: FXPorts: 4Connector: LCDistance: 2 km (1.2 mi)

Article Numbers6GK6050-0ML20-0BH1 (Module)6GK6050-0RL20-0BH1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-4MM0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN LM M4FG01 SpecificationsMode: MMSpeed: 1000 MbpsInterface: SXWavelength: 850 nmPorts: 4Connector: LCDistance: 500 m (1640 ft)

Article Numbers6GK6050-0ML20-0BK1 (Module)6GK6050-0RL20-0BK1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-4MM0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN LM M4FG03 SpecificationsMode: SMSpeed: 1000 MbpsInterface: LXWavelength: 1310 nmPorts: 4Connector: LCDistance: 10 Km (6 mi)

Article Numbers6GK6050-0ML20-0CR1 (Module)6GK6050-0RL20-0CR1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-4SM0 (PatchPanel and Cables)

Serial ModulesRUGGEDCOM MX5000REPN LM MS01 Specifications

Standard: RS232/RS422/RS485Ports: 8Connector: DB9

Article Numbers6GK6050-0ML20-0KB1 (Module)6GK6050-0RL20-0KB1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-8DR0 (PatchPanel and Cables)

Control ModulesRUGGEDCOM MX5000REPN MCM01 L3SEL3HW Specifications

Layer 3 Standard Edition, Layer 3Hardware

Article Numbers6GK6050-0ML30-0BA1 (Module)6GK6050-0RL30-0BA1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-1CP0 (PatchPanel and Cables)

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

4 Available Modules

RUGGEDCOM MX5000REPN MCM01 L3SECL3HW SpecificationsLayer 3 Security Edition, Layer 3Hardware

Article Numbers6GK6050-0ML30-0CA1 (Module)6GK6050-0RL30-0CA1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-1CP0 (PatchPanel and Cables)

Switch ModulesRUGGEDCOM MX5000REPN MSM36 Specifications

Mode: SMSpeed: 1000 MbpsInterface: LXWavelength: 1310 nmPorts: 2Connector: LCDistance: 10 Km (6 mi)

Article Numbers6GK6050-0ML40-0RA1 (Module)6GK6050-0RL40-0RA1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-1SP0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN MSM61 SpecificationsLayer 3

Article Numbers6GK6050-0ML40-0VA1 (Module)6GK6050-0RL40-0VA1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-0XF0 (PatchPanel and Cables)

RUGGEDCOM MX5000REPN MSM70 SpecificationsSFP Sockets: 2Speed: 10 GbpsNetwork Layer: Layer 3

Article Numbers6GK6050-0ML40-0XA1 (Module)6GK6050-0RL40-0WA1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-1SP0 (PatchPanel and Cables)

Network Redundancy ModulesRUGGEDCOM MX5000REPN LM MPRP Specifications

Ports: 2Speed: 1000 MbpsInterface: LXPort Type: RJ45Distance: 10 km (6.2 mi)Protocol: PRP

Article Numbers6GK6050-0ML20-0PR1 (Module)6GK6050-0RL20-0PR1 (Modulewith Patch Panel and Cables)6GK6050-0AR00-2PR0 (PatchPanel and Cables)

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Available Modules 5

Blank ModulesRUGGEDCOM MX5000REPN PS XX Specifications

Blank power supply module, fullpanel

Article Numbers6GK6050-0RL10-0AA1

RUGGEDCOM MX5000REPN LM XX SpecificationsBlank line module, half panel

Article Numbers6GK6050-0RL20-0AA1

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

6 Installing/Removing Modules

Section 1.2

Installing/Removing ModulesAlways refer to the Installation Guide for the RUGGEDCOM MX5000RE for instructions on how to install or removea power or line module. The Installation Guide cites important, chassis-specific safety warnings that should befollowed to avoid damage to the module and/or device.Additional installation/removal instructions may also be provided in this Catalog for select modules. Make sure toreview all information provided for a module before installing or removing it.

RUGGEDCOM ModulesCatalog

Chapter 1Introduction

Dimensions 7

Section 1.3

DimensionsPower and line modules conform to the following dimensions:

NOTEAll dimensions are in millimeters (mm).

242.

1

180.1

180.1

Figure 1: Power and Line Module Dimensions

Chapter 1Introduction

RUGGEDCOM ModulesCatalog

8 Dimensions

RUGGEDCOM ModulesCatalog

Chapter 2Power Supply Modules

9

Power Supply ModulesThe following power supply modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 2.1, “RUGGEDCOM MX5000REPN PS MHIF”

Chapter 2Power Supply Modules

RUGGEDCOM ModulesCatalog

10 RUGGEDCOM MX5000REPN PS MHIF

Section 2.1

RUGGEDCOM MX5000REPN PS MHIFThe RUGGEDCOM MX5000REPN PS MHIF power supply module provides high VDC or VAC power to theRUGGEDCOM MX5000RE and features a failsafe relay to protect against critical error conditions. The moduleaccepts either AC or DC power inputs from an external power supply.

IMPORTANT!The required power input for the RUGGEDCOM MX5000REPN PS MHIF is located on the chassis.For more information about the RUGGEDCOM MX5000RE chassis options, refer to Article Number6GK6050-0MB00-0AG1 and 6GK6050-0MB00-0AG2.

LEDs indicate when the module is receiving and supplying power.

1 2

Figure 2: RUGGEDCOM MX5000REPN PS MHIF1. I LED 2. O LED

LED State Description

O Green The module is supplying power

I Green The module is receiving power

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsCharacteristics

Input Range 88 to 300 VDC or 85 to 264 VAC

Internal Fuse Rating 6.3 A, 250 V(T)a

Maximum PowerConsumptionb

84 Wc

Insulation 2800 VDC for 1 minute

Environment

Ingress Protection IP30

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

a (T) denotes time-delay fuse. Internal fuse is not user-replaceable.

b Power consumption varies based on the device configuration.

c Rating at 85 °C (185 °F) ambient temperature at worst-case load.

Ordering InformationDescription 88-300VDC or 85 264VAC, supports terminal block on front.

Article Numbers 6GK6050-0RL16-0AA1

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

11

Copper Ethernet ModulesThe following copper Ethernet modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 3.1, “RUGGEDCOM MX5000REPN LM M4CG02”• Section 3.2, “RUGGEDCOM MX5000REPN LM M8TX02”• Section 3.3, “RUGGEDCOM MX5000REPN LM M12TX01”

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

12 RUGGEDCOM MX5000REPN LM M4CG02

Section 3.1

RUGGEDCOM MX5000REPN LM M4CG02The RUGGEDCOM MX5000REPN LM M4CG02 module features four 10/100/1000Base-TX Micro-D ports.

IMPORTANT!This module is only compatible with RUGGEDCOM MX5000REPN SM 61.

Each port features a dedicated LED that indicates its link/activity state.

2

3 31

Figure 3: RUGGEDCOM MX5000REPN LM M4CG021. Alarm LED 2. Micro-D Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Pin-Out DescriptionThe following are the pin-out descriptions for the Micro-D ports:

6

1

Figure 4: Micro-D 10/100Base-TX Port Pin Configuration

Pin 10/100Base-TX 1000Base-TX

1 TX+ B+

2 Reserved (DoNot Connect)

D+

3 Reserved (Do Not Connect)

4 Reserved (DoNot Connect)

C+

5 RX+ A+

6 TX- B-

7 Reserved (DoNot Connect)

D-

8 Reserved (DoNot Connect)

C-

9 RX- A-

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

RUGGEDCOM MX5000REPN LM M4CG02 13

Technical SpecificationsCharacteristics

Speed 10/100/1000 Mbps

Interface TX

Connector Micro-D

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 4 x 10/100/1000TX Micro-D 6GK6050-0ML20-0FD1

Module with Patch Panel and Cables 4 x 10/100/1000TX Micro-D 6GK6050-0RL20-0FD1

Patch Panel and Cables 4 x Micro-D connectors to RJ45 connectors 6GK6050-0AR00-4RD0

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

14 RUGGEDCOM MX5000REPN LM M8TX02

Section 3.2

RUGGEDCOM MX5000REPN LM M8TX02The RUGGEDCOM MX5000REPN LM M8TX02 module features eight 10/100Base-TX Micro-D ports.Each port features a dedicated LED that indicates its link/activity state.

3

2 2

1

Figure 5: RUGGEDCOM MX5000REPN LM M8TX021. Alarm LED 2. Port LEDs 3. Micro-D Ports

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Pin-Out DescriptionThe following are the pin-out descriptions for the Micro-D ports:

6

1

Figure 6: Micro-D 10/100Base-TX Port Pin Configuration

Pin 10/100Base-TX 1000Base-TX

1 TX+ B+

2 Reserved (DoNot Connect)

D+

3 Reserved (Do Not Connect)

4 Reserved (DoNot Connect)

C+

5 RX+ A+

6 TX- B-

7 Reserved (DoNot Connect)

D-

8 Reserved (DoNot Connect)

C-

9 RX- A-

Technical SpecificationsCharacteristics Environment

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

RUGGEDCOM MX5000REPN LM M8TX02 15

Speed 10/100 Mbps

Interface TX

Connector Micro-D

Duplex FDX/HDX

Cable Type > CAT-5

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 8 x 10/100Base-TX Micro-D 6GK6050-0ML20-0ND1

Module with Patch Panel and Cables 8 x 10/100Base-TX Micro-D 6GK6050-0RL20-0ND1

Patch Panel and Cables 8 x Micro-D connectors to RJ45 connectors 6GK6050-0AR00-8RD0

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

16 RUGGEDCOM MX5000REPN LM M12TX01

Section 3.3

RUGGEDCOM MX5000REPN LM M12TX01The RUGGEDCOM MX5000REPN LM M12TX01 module features sixteen 10/100 Base-TX RJ45 ports, but only twelveports are connected to the RUGGEDCOM MX5000RE enclosure via the associated patch panel.The module features two dedicated LEDs to indicate link/activity state.

41

2 3

Figure 7: RUGGEDCOM MX5000REPN LM M12TX011. Alarm LED 2. Speed LED 3. Link/Activity LED 4. EthernetPorts

LED State Description

Yellow The port is operatingat 1000 Mbps

Speed

Off The port is operatingat 10 or 100 Mbps

Yellow (Solid) Link established

Yellow (Blinking) Activity

Link/Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Pin-Out DescriptionThe following are the pin-out descriptions for the RJ45 ports:

18

Figure 8: RJ45 Ethernet Port Pin Configuration

NamePin

10/100Base-TX 1000Base-TXDescription

1 RX+ BI_DB+ Receive Data+or Bi-Directional

2 RX- BI_DB- Receive Data-or Bi-Directional

3 TX+ BI_DA+ Transmit Data+or Bi-Directional

4 Reserved (Do Not Connect)

5 Reserved (Do Not Connect)

6 TX- BI_DA- Transmit Data-or Bi-Directional

7 Reserved (Do Not Connect)

8 Reserved (Do Not Connect)

RUGGEDCOM ModulesCatalog

Chapter 3Copper Ethernet Modules

RUGGEDCOM MX5000REPN LM M12TX01 17

Technical SpecificationsCharacteristics

Speed 10/100 Mbps

Interface TX

Connector RJ45

Cable Type > CAT-5

Duplex FDX/HDX

Wiring Standard TIA/EIA T568A/B

Nominal Distance 100 m (328.1 ft)

Isolation 1.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 16 x 10/100Base-TX RJ45 6GK6050-0ML20-0NB1

Module with Patch Panel and Cables 12 x 10/100Base-TX RJ45 6GK6050-0RL20-0NE1

Patch Panel and Cables 12 x RJ45 connectors to RJ45 connectors 6GK6050-0AR00-6RR0

Chapter 3Copper Ethernet Modules

RUGGEDCOM ModulesCatalog

18 RUGGEDCOM MX5000REPN LM M12TX01

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

19

Fiber Optic Ethernet ModulesThe following fiber optic Ethernet modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 4.1, “RUGGEDCOM MX5000REPN LM M4FG01”• Section 4.2, “RUGGEDCOM MX5000REPN LM M4FG03”• Section 4.3, “RUGGEDCOM MX5000REPN LM M4FX11”• Section 4.4, “RUGGEDCOM MX5000REPN LM M8FX11”

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

20 RUGGEDCOM MX5000REPN LM M4FG01

Section 4.1

RUGGEDCOM MX5000REPN LM M4FG01The RUGGEDCOM MX5000REPN LM M4FG01 module features four 1000Base-SX fiber optic Ethernet ports.

IMPORTANT!This module is only compatible with RUGGEDCOM MX5000REPN SM 61.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

3 31

Figure 9: RUGGEDCOM MX5000REPN LM M4FG011. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -9 to -2.5 dBm

Receiver Sensitivity -20 dBm

Receiver Saturation 0 dBm

Power Budget 11 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Cabling

Speed 1 Gbps

Mode MM (Multi-Mode)

Interface SX

Connector LC

Cable Type 62.5/125 μm

Wavelengtha 850 nm

Nominal Distancea 0.5 km (0.3 mi)

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM MX5000REPN LM M4FG01 21

Storage Temperature -40 to 85 °C (-40 to 185 °F)a Typical.

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 4 x 1000SX, Multimode, 850nm, LC, 500m 6GK6050-0ML20-0BK1

Module with Patch Panel and Cables 4 x 1000SX, Multimode, 850nm, LC, 500m 6GK6050-0RL20-0BK1

Patch Panel and Cables 4 x Multi Mode Military Circular FiberConnectors with LC connectors

6GK6050-0AR00-4MM0

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

22 RUGGEDCOM MX5000REPN LM M4FG03

Section 4.2

RUGGEDCOM MX5000REPN LM M4FG03The RUGGEDCOM MX5000REPN LM M4FG03 module features four 1000Base-LX fiber optic Ethernet ports.

IMPORTANT!This module is only compatible with RUGGEDCOM MX5000REPN SM 61.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

1

2 2

Figure 10: RUGGEDCOM MX5000REPN LM M4FG031. Ethernet Ports 2. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -9.5 to -3 dBm

Receiver Sensitivity -21 dBm

Receiver Saturation -3 dBm

Power Budget 11.5 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Cabling

Speed 1000Base-LX

Mode Single-Mode

Interface LC

Cable Type 9/125 μm

Wavelengthb 1310 nm

Nominal Distancea 10 km (6.2 mi)

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM MX5000REPN LM M4FG03 23

Storage Temperature -40 to 85 °C (-40 to 185 °F)b Typical.

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 4x 1000LX Singlemode, 1310nm, LC, 10km 6GK6050-0ML20-0CR1

Module with Patch Panel and Cables 4x 1000LX Singlemode, 1310nm, LC, 10km 6GK6050-0RL20-0CR1

Patch Panel and Cables 4 x Single Mode Military Circular FiberConnectors with LC connectors

6GK6050-0AR00-4SM0

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

24 RUGGEDCOM MX5000REPN LM M4FX11

Section 4.3

RUGGEDCOM MX5000REPN LM M4FX11The RUGGEDCOM MX5000REPN LM M4FX11 module features four 100Base-FX fiber optic Ethernet ports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

1 33

2

Figure 11: RUGGEDCOM MX5000REPN LM M4FX111. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -19 to -14 dBm

Receiver Sensitivity -32 dBm

Receiver Saturation -14 dBm

Power Budget 13 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 100 Mbps

Mode MM (Multi-Mode)

Interface FX

Connector LC

Cable Type 62.5/125 μm

Wavelengthc 1300 nm

Nominal Distancea 2 km (1.2 mi)

c Typical.

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM MX5000REPN LM M4FX11 25

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 4 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0ML20-0BH1

Module with Patch Panel and Cables 4 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0RL20-0BH1

Patch Panel and Cables 4 x Multi Mode Military Circular FiberConnectors with LC connectors

6GK6050-0AR00-4MM0

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

26 RUGGEDCOM MX5000REPN LM M8FX11

Section 4.4

RUGGEDCOM MX5000REPN LM M8FX11The RUGGEDCOM MX5000REPN LM M8FX11 module features eight 100Base-FX fiber optic Ethernet ports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

1

2 3 3

Figure 12: RUGGEDCOM MX5000REPN LM M8FX111. Ethernet Ports 2. Alarm LED 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -19 to -14 dBm

Receiver Sensitivity -32 dBm

Receiver Saturation -14 dBm

Power Budget 13 dB

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 100 Mbps

Mode MM (Multi-Mode)

Interface FX

Connector LC

Cable Type 62.5/125 μm

Wavelengthd 1300 nm

Nominal Distance 2 km (1.2 mi)

d Typical.

RUGGEDCOM ModulesCatalog

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM MX5000REPN LM M8FX11 27

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 8 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0ML20-0BD1

Module with Patch Panel and Cables 8 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0RL20-0BD1

Patch Panel and Cables 8 x Multi Mode Military Circular FiberConnectors with LC connectors

6GK6050-0AR00-8MM0

Chapter 4Fiber Optic Ethernet Modules

RUGGEDCOM ModulesCatalog

28 RUGGEDCOM MX5000REPN LM M8FX11

RUGGEDCOM ModulesCatalog

Chapter 5Serial Modules

29

Serial ModulesThe following serial modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 5.1, “RUGGEDCOM MX5000REPN LM MS01”

Chapter 5Serial Modules

RUGGEDCOM ModulesCatalog

30 RUGGEDCOM MX5000REPN LM MS01

Section 5.1

RUGGEDCOM MX5000REPN LM MS01The RUGGEDCOM MX5000REPN LM MS01 module features eight serial DB9 ports that may be used with a nullmodem (crossover) serial cable.

2

1

Figure 13: RUGGEDCOM MX5000PN LM MS01

1. Alarm LED 2. Serial Ports

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Operating ModesEach serial port can be run in RS232, RS485 or RS422 mode.On initial power-up, all serial ports default to RS485 mode. However, each port can be individually set to RS232,RS485 or RS422 mode via RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guidefor the RUGGEDCOM MX5000RE.

Pin-Out DescriptionThe following are the pin-outs for the DB9 connectors:

115

69

Figure 14: DB9 Serial Port

FunctionPin

RS232 Mode RS422 Mode RS485 Mode

1 RX-

2 RX TX+ TX+/RX+

3 TX RX+

4 Reserved (Do Not Connect)

5 COM (Isolated GND)

6 COM (Isolated GND)

7 TX- TX-/RX-

8 Reserved (Do Not Connect)

RUGGEDCOM ModulesCatalog

Chapter 5Serial Modules

RUGGEDCOM MX5000REPN LM MS01 31

FunctionPin

RS232 Mode RS422 Mode RS485 Mode

9 COM (Isolated GND)

Body Chassis GNDa

Screws Chassis GNDa

a Connected internally.

Connecting to RS485 DevicesEach RS485 port can communicate with multiple RS485 devices by wiring devices together in sequence over asingle twisted pair with transmit and receive signals on the same two wires (half duplex). For reliable, continuouscommunication, adhere to the following guidelines:• To minimize the effects of ambient electrical noise, use shielded cabling.• The correct polarity must be observed throughout a single sequence or ring.• The number of devices wired should not exceed 32, and total distance should be less than 1219 m (4000 ft) at

100 kbps.• The Common terminals should be connected to the common wire inside the shield.• The shield should be connected to earth ground at a single point to avoid loop currents.• The twisted pair should be terminated at each end of the chain.The following shows the recommended RS485 wiring.

< 12

19 m

(40

00 in

)

120Ω 10nF

120Ω 10nF

1

2

3 5

5

6

4

Figure 15: Recommended RS485 Wiring

1. MX5000RE Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth (Connected At a Single Point) 6. RS485Devices (32 Total)

Chapter 5Serial Modules

RUGGEDCOM ModulesCatalog

32 RUGGEDCOM MX5000REPN LM MS01

Technical SpecificationsCharacteristics

Baud Rate 1200 to 230400 kbps

Connector DB9

Isolation 2.5 kV

Environment

Ingress Protection IP40

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

CertificationThis module has been certified to comply with the requirements of the relevant standards.

Category Standard

EMC FCC Part 15 (Class A), EN 55022 (CISPR22 Class A), IEC 61850-3, IEEE 1613

Safety UL 60950-1, CSA C22.2 No. 60950-7

Hazardous Location (CSA/UL) Class I, Div 2

Emitted Interference EN 61000-6-4 (Class A)

Interference Immunity EN 61000-6-2

Railway EN 50155, EN 50124-1

Ordering InformationItem Description Article Number

Module 8 x RS232/RS422/RS485 via DB9 Serial LineModule

6GK6050-0ML20-0KB1

Module with Patch Panel and Cables 8 x RS232/RS422/RS485 via DB9 Serial LineModule

6GK6050-0RL20-0KB1

Patch Panel and Cables Panels for MX5000RE Serial module. 6GK6050-0AR00-8DR0

RUGGEDCOM ModulesCatalog

Chapter 6Control Modules

33

Control ModulesControl modules are the central processing engine for the device. The RUGGEDCOM ROX II operating systemrunning on the module controls and coordinates the functions of all modules installed in the system.Each control module is equipped with an RS232 serial console port for initial management functions, and a locallyconnected 10/100Base-T Ethernet port for system management out-of-band from the switch fabric.Other features include:• Alarm LED to indicate the system status• Removable 1 GB Compact Flash (CF) card, which contains active and fallback installations of the RUGGEDCOM

ROX II operating system, the configuration database, and other system data• A failsafe alarm relay, activated by the operating system to indicate a critical alarm.• A lamp test and alarm cutoff button• A utility USB port for uploading/downloading filesThe following control modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 6.1, “RUGGEDCOM MX5000REPN MCM01 L3SEL3HW”• Section 6.2, “RUGGEDCOM MX5000REPN CM01 L3SECL3HW”

Chapter 6Control Modules

RUGGEDCOM ModulesCatalog

34 RUGGEDCOM MX5000REPN MCM01 L3SEL3HW

Section 6.1

RUGGEDCOM MX5000REPN MCM01 L3SEL3HWThe RUGGEDCOM MX5000REPN MCM01 L3SEL3HW control module features Layer 3 hardware and is pre-configured with RUGGEDCOM ROX II Layer 3 Standard Edition.

3 4 5 6 7

1 2

Figure 16: RUGGEDCOM MX5000REPN MCM01 L3SEL3HW1. LT/ACO Button 2. CF Card Slot 3. Alarm LED 4. MGMT Port 5. USB Port 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationItem Description Article Number

Module Control module with Layer 3 StandardEdition Layer 3 hardware

6GK6050-0ML30-0BA1

Module with Patch Panel and Cables Control module with Layer 3 StandardEdition Layer 3 hardware

6GK6050-0RL30-0BA1

Patch Panel and Cables Panels for MX5000RE Control Module 6GK6050-0AR00-1CP0

RUGGEDCOM ModulesCatalog

Chapter 6Control Modules

RUGGEDCOM MX5000REPN CM01 L3SECL3HW 35

Section 6.2

RUGGEDCOM MX5000REPN CM01 L3SECL3HWThe RUGGEDCOM MX5000REPN CM01 L3SECL3HW control module features Layer 3 hardware and is pre-configured with RUGGEDCOM ROX II Layer 3 Security Edition.

3 4 5 6 7

1 2

Figure 17: RUGGEDCOM MX5000REPN CM01 L3SECL3HW1. LT/ACO Button 2. CF Card Slot 3. Alarm LED 4. MGMT Port 5. USB Port 6. Console Port 7. Failsafe Relay

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationItem Description Article Number

Module Control module with Layer 3 Security EditionLayer 3 hardware

6GK6050-0ML30-0CA1

Module with Patch Panel and Cables Control module with Layer 3 Security EditionLayer 3 hardware

6GK6050-0RL30-0CA1

Patch Panel and Cables Panels for MX5000RE Control Module 6GK6050-0AR00-1CP0

Chapter 6Control Modules

RUGGEDCOM ModulesCatalog

36 RUGGEDCOM MX5000REPN CM01 L3SECL3HW

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

37

Switch ModulesSwitch modules connect devices together on a computer network by using packet switching to receive, processand forward data to the destination device.The following switch modules are available for the RUGGEDCOM MX5000RE.

CONTENTS• Section 7.1, “RUGGEDCOM MX5000REPN MSM36”• Section 7.2, “RUGGEDCOM MX5000REPN SM MSM61”• Section 7.3, “RUGGEDCOM MX5000REPN SM MSM70”

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

38 RUGGEDCOM MX5000REPN MSM36

Section 7.1

RUGGEDCOM MX5000REPN MSM36The RUGGEDCOM MX5000REPN MSM36 module features two 1000Base-LX fiber optic Ethernet ports.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state.

2

1 3

Figure 18: RUGGEDCOM MX5000REPN MSM361. Alarm LED 2. Ethernet Ports 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -10 to -3 dBm

Receiver Sensitivity -20 dBm

Receiver Saturation -3 dBm

Power Budget 10 dB

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 1 Gbps

Mode SM (Single-Mode)

Interface LX

Connector LC

Cable Type 9/125 μm

Wavelengtha 1310

Nominal Distancea 10 km (6.2 mi)

a Typical.

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM MX5000REPN MSM36 39

Ordering InformationItem Description Article Number

Module 2x 1000LX singlemode, 1310nm, LC, 10km 6GK6050-0ML40-0RA1

Module with Patch Paneland Cables

2x 1000LX singlemode, 1310nm, LC, 10km 6GK6050-0RL40-0RA1

Patch Panel and Cables 2 x Singlemode Military Circular Fiber Connectors withLC connectors

6GK6050-0AR00-1SP0

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

40 RUGGEDCOM MX5000REPN SM MSM61

Section 7.2

RUGGEDCOM MX5000REPN SM MSM61The RUGGEDCOM MX5000REPN SM MSM61 is a Layer 3/88 Gigabit throughput switch module that enablesGigabit throughput for up to 24 fiber optic Ethernet ports.

1

Figure 19: RUGGEDCOM MX5000REPN SM MSM611. Alarm LED

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOperating Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationItem Description Article Number

Module Layer 3/88 Gigabit Throughput, no uplinkports

6GK6050-0ML40-0VA1

Module with Patch Panel and Cables Layer 3/88 Gigabit Throughput, no uplinkports

6GK6050-0RL40-0VA1

Patch Panel and Cables Full Blank Panel 6GK6050-0AR00-0XF0

RUGGEDCOM ModulesCatalog

Chapter 7Switch Modules

RUGGEDCOM MX5000REPN SM MSM70 41

Section 7.3

RUGGEDCOM MX5000REPN SM MSM70The RUGGEDCOM MX5000REPN SM MSM70 is a Layer 3/88 Gigabit throughput switch module that enablesGigabit throughput for up to 24 fiber optic Ethernet ports. It also features sockets for up to two Small Form-factorPluggable (SFP) transceivers.

NOTEWhen connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port areproperly connected and matched to establish a proper link.

Each transceiver socket features a dedicated LED that indicates the link/activity state of the associated SFPtransceiver.

2

1 3

Figure 20: RUGGEDCOM MX5000REPN SM MSM701. Alarm LED 2. SFP Transceiver Sockets 3. Port LEDs

State Description

Green (Solid) Link established

Green (Blinking) Activity

Off No link detected

This module is only compatible with the following fiber optic Ethernet modules:• RUGGEDCOM MX5000REPN LM M8FX11

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -8.2 to 0.5 dBm

Tx Minimum OMA -5.2

Minimum Extinction Ratio 3.5

Receiver Sensitivity OMA(dBm)

-12.6

Stressed RX Sensitivity (dBm) -10.3

Receiver Saturation (dBm) 0.5

Power Budget (dB) 4.4

Cabling

Speed 10 Gbps

Mode SM (Single-Mode)

Interface LR

Connector LC

Cable Type 9/125 μm

Wavelength 1310 nm

Nominal Distance 10 km (6.2 mi)

Chapter 7Switch Modules

RUGGEDCOM ModulesCatalog

42 RUGGEDCOM MX5000REPN SM MSM70

Channel Insertion Loss (dB) 5.1

Allocation for Penalties (dB) 2.3

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 0 to 85% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Ordering InformationItem Description Article Number

Module Layer 3/88 Gigabit Throughput, 2x 10G 6GK6050-0ML40-0XA1

Module with Patch Panel and Cables Layer 3/88 Gigabit Throughput, 2x 10G 6GK6050-0RL40-0WA1

Patch Panel and Cables 2 x Singlemode Military Circular FiberConnectors with LC connectors

6GK6050-0AR00-1SP0

RUGGEDCOM ModulesCatalog

Chapter 8Network Redundancy Modules

43

Network Redundancy ModulesThe following modules provide network redundancy functionality for the RUGGEDCOM MX5000RE.

CONTENTS• Section 8.1, “RUGGEDCOM MX5000REPN LM MPRP”

Chapter 8Network Redundancy Modules

RUGGEDCOM ModulesCatalog

44 RUGGEDCOM MX5000REPN LM MPRP

Section 8.1

RUGGEDCOM MX5000REPN LM MPRPThe RUGGEDCOM MX5000REPN LM MPRP module enables the device the interact with a redundancy networkusing the Parallel Redundancy Protocol (PRP). The module features individual Ethernet ports for connecting toeach side of the network.

NOTEFor more information about PRP, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOMMX5000RE.

4

321

5

Figure 21: RUGGEDCOM MX5000REPN LM MPRP

1. Alarm LED 2. Ethernet Ports 3. Port LEDs

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Technical SpecificationsOptical Characteristics

Transmit Power -9.5 to -3.0 dBm

Receiver Sensitivity -19.0 to -3.0 dBm

Power Budget 9.5 dB

Environment

Operating Temperature -40 to 85 °C (-40 to 185 °F)

Operating Relative Humidity 5 to 95% (non-condensing)

Storage Temperature -40 to 85 °C (-40 to 185 °F)

Cabling

Speed 1 Gbps

Mode SM (Single-Mode)

Interface LX

Connector LC

Cable Type 9/125 μm

Wavelength 1310 nm

Nominal Distance 10 km (6.2 mi)

RUGGEDCOM ModulesCatalog

Chapter 8Network Redundancy Modules

RUGGEDCOM MX5000REPN LM MPRP 45

Ordering InformationItem Description Article Number

Module 1x Pair (A/B) Gigabit PRP with 2x single-modeLC 10km Conformal Coating

6GK6050-0ML20-0PR1

Module with Patch Panel and Cables 1x Pair (A/B) Gigabit PRP with 2x single-modeLC 10km Conformal Coating

6GK6050-0RL20-0PR1

Patch Panel and Cables Panels for MX500RE PRP module 6GK6050-0AR00-2PR0

Chapter 8Network Redundancy Modules

RUGGEDCOM ModulesCatalog

46 RUGGEDCOM MX5000REPN LM MPRP

RUGGEDCOM ModulesCatalog

Chapter 9Blank Modules

47

Blank ModulesThe following blank modules are available for the RUGGEDCOM MX5000RE.

IMPORTANT!Blank modules should be installed in empty slots to prevent the ingress of dirt or debris in the chassis.

CONTENTS• Section 9.1, “RUGGEDCOM MX5000REPN PS XX”• Section 9.2, “RUGGEDCOM MX5000REPN LM XX”

Chapter 9Blank Modules

RUGGEDCOM ModulesCatalog

48 RUGGEDCOM MX5000REPN PS XX

Section 9.1

RUGGEDCOM MX5000REPN PS XXThe RUGGEDCOM MX5000REPN PS XX is a blank module designed to occupy empty power supply module slots inthe RUGGEDCOM MX5000RE chassis.

Figure 22: RUGGEDCOM MX5000REPN PS XX

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Ordering InformationDescription Power Supply Blank Module, Full Panel

Article Numbers 6GK6050-0RL10-0AA1

RUGGEDCOM ModulesCatalog

Chapter 9Blank Modules

RUGGEDCOM MX5000REPN LM XX 49

Section 9.2

RUGGEDCOM MX5000REPN LM XXThe RUGGEDCOM MX5000REPN LM XX is a blank module designed to occupy empty line module slots in theRUGGEDCOM MX5000RE chassis.

Figure 23: RUGGEDCOM MX5000REPN LM XX

Installing the ModuleFor information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE.

Ordering InformationDescription Blank Module

Article Numbers 6GK6050-0RL20-0AA1

Chapter 9Blank Modules

RUGGEDCOM ModulesCatalog

50 RUGGEDCOM MX5000REPN LM XX