Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control FRENIC-Lift (LM2) series of inverters. • This manual provides all the information on Fuji’s inverter support software FRENIC Loader FRENIC-LIFT (LM2). Read this manual carefully for correct use of FRENIC Loader FRENIC-LIFT (LM2) • This manual does not contain information on the inverter itself. Read the inverter reference manual, inverter instruction manual in conjunction with this manual. Incorrect handling may prevent Loader from operating correctly, shorten the inverter service life, or cause problems. Fuji Electric Co., Ltd. INR-SI47-1971

Upload: others

Post on 26-Feb-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Inverter Support Software

FRENIC Loader

Instruction Manual

Thank you for purchasing our high-performance, vector control FRENIC-Lift (LM2) series of inverters.

• This manual provides all the information on Fuji’s inverter support software FRENIC Loader FRENIC-LIFT (LM2).

Read this manual carefully for correct use of FRENIC Loader FRENIC-LIFT (LM2)

• This manual does not contain information on the inverter itself. Read the inverter reference manual, inverter instruction manual in conjunction with this manual.

• Incorrect handling may prevent Loader from operating correctly, shorten the inverter service life, or cause problems.

Fuji Electric Co., Ltd. INR-SI47-1971

Page 2: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Copyright © 2015 Fuji Electric Co., Ltd.

All rights reserved.

No part of this publication may be reproduced or copied without prior written permission from Fuji

Electric Systems Co., Ltd.

Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States. All

other products and company names mentioned in this manual are trademarks or registered trademarks

of their respective holders.

The information contained herein is subject to change without prior notice for improvement.

Page 3: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

i

Preface

This manual provides all the information on Fuji’s inverter support software FRENIC Loader.

Read this manual carefully for correct use of FRENIC Loader.

This manual does not contain information on the inverter itself. Read the inverter reference manual,

inverter instruction manual in conjunction with this manual.

Incorrect handling may prevent Loader from operating correctly, shorten the inverter service life, or

cause problems.

■Safety Precautions

Read this manual thoroughly before proceeding with installation, connections (wiring), or operation.

Ensure you have sound knowledge of the device and software and have familiarized yourself with all

safety information and precautions before proceeding to operate the inverter via FRENIC Loader.

Safety precautions are classified into the following two categories in this manual.

Failure to heed the information indicated by this symbol may result in death

or serious injury.

Failure to heed the information indicated by this symbol may result in minor

or light injury and/or substantial property damage.

Wiring and Connection of Cables

• Be sure to turn off the power to the inverters and related devices before making RS-485

connection.

Risk of electric shock if this warning is not heeded.

Page 4: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

ii

Contents

Chapter1 Before Using FRENIC Loader ............................................................................................................... 5

1.1. Overview ....................................................................................................................................................... 5

1.1.1. Features ........................................................................................................................................ 5

1.1.2. Warranty ........................................................................................................................................ 5

1.2. Connecting Inverters to a PC ........................................................................................................................ 6

1.2.1. Connection .................................................................................................................................... 6

1.2.2. Configuring an RS-485 communications network .......................................................................... 7

1.2.2.1. Example of networking .................................................................................................................. 7

1.2.2.2. Communications support devices for RS-485 ................................................................................ 8

1.2.2.3. Noise suppression ......................................................................................................................... 9

1.2.3. Configuring USB network ............................................................................................................ 10

1.2.3.1. Example of networking ................................................................................................................ 10

1.3. Installation ................................................................................................................................................... 11

1.3.1. Installing software ........................................................................................................................ 11

1.3.1.1. Installing loader ........................................................................................................................... 12

1.3.1.2. Installing Message Manager ........................................................................................................ 15

1.3.1.3. Installing USB driver .................................................................................................................... 18

1.3.1.4. Checking the installation of the USB driver .................................................................................. 22

1.3.2. Uninstallation ............................................................................................................................... 23

1.3.2.1. Uninstalling FRENIC Loader ........................................................................................................ 23

1.3.2.2. Before uninstalling Message Manager......................................................................................... 24

1.3.2.3. Uninstalling Message Manager ................................................................................................... 25

1.4. Configuring the Settings for Inverter(s) and Loader ..................................................................................... 26

1.4.1. Configuring communication-related function codes in the inverter .............................................. 26

1.4.2. Checking the COM port on the PC (when using a communications level converter) ................... 27

1.4.3. Configuring Loader ...................................................................................................................... 28

1.4.4. Communication Settings .............................................................................................................. 30

1.4.5. Connection settings ..................................................................................................................... 33

Chapter2 Description of Functions ...................................................................................................................... 35

2.1. Main Window ............................................................................................................................................... 35

2.2. File .............................................................................................................................................................. 36

2.2.1. Create New File ........................................................................................................................... 36

2.2.2. Open ............................................................................................................................................ 36

2.2.3. Close ........................................................................................................................................... 36

2.2.4. Save ............................................................................................................................................ 37

2.2.5. Save As… .................................................................................................................................... 37

2.2.6. Print ............................................................................................................................................. 37

2.2.7. Print Preview ............................................................................................................................... 38

2.2.8. Page Setup .................................................................................................................................. 38

2.2.9. End .............................................................................................................................................. 38

2.3. Menu ........................................................................................................................................................... 39

2.3.1. Function Code Setting ................................................................................................................. 39

2.3.1.1. Open the customizable logic setting window ............................................................................... 39

2.3.1.2. Create New Function Setting ....................................................................................................... 39

2.3.1.3. Read File from the PC ................................................................................................................. 39

Page 5: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

iii

2.3.1.4. Read from the Inverter ................................................................................................................. 39

2.3.1.5. Edit List ........................................................................................................................................ 39

2.3.1.6. Auto Tuning ................................................................................................................................. 50

2.3.1.7. File Information ............................................................................................................................ 51

2.3.2. Operation monitor ........................................................................................................................ 56

2.3.2.1. I/O monitor (for control terminal input/output signal status of the inverter) ................................... 56

2.3.2.2. System monitor (for current setup info and maintenance info of inverter).................................... 57

2.3.2.3. Alarm monitor .............................................................................................................................. 58

2.3.2.4. Operation status monitor (Monitor the operation information of the inverter) ............................... 59

2.3.3. Customizable logic function ......................................................................................................... 60

2.3.3.1. Selecting Project .......................................................................................................................... 60

2.3.3.2. Editor screen ............................................................................................................................... 61

2.3.3.3. Customizable Function Creation Procedure ................................................................................ 62

2.3.3.4. Downloading to the Inverter ......................................................................................................... 76

2.3.3.5. Comparison ................................................................................................................................. 77

2.3.3.6. Debug .......................................................................................................................................... 79

2.3.3.7. List of Customizable function Symbols ........................................................................................ 82

2.3.3.8. Specifications of Customizable function ...................................................................................... 94

2.3.4. Tace............................................................................................................................................. 95

2.3.4.1. Real-time trace ............................................................................................................................ 95

2.3.4.2. Historical trace ............................................................................................................................. 96

2.3.4.3. Monitor Start/Stop ........................................................................................................................ 97

2.3.4.4. Save Trace Data .......................................................................................................................... 98

2.3.4.5. Copy Trace Data Screen ............................................................................................................. 98

2.3.4.6. Print Trace Data .......................................................................................................................... 99

2.3.4.7. Sub Window .............................................................................................................................. 100

2.3.4.8. Waveform Detail Settings .......................................................................................................... 104

2.3.4.9. Combination of a customizable logic functions .......................................................................... 112

2.4. Setup ......................................................................................................................................................... 114

2.4.1. Communication Setup ............................................................................................................... 114

2.4.2. Language ................................................................................................................................... 114

2.5. View .......................................................................................................................................................... 115

2.6. Toolbar ...................................................................................................................................................... 115

2.7. Status bar .................................................................................................................................................. 115

2.8. Window...................................................................................................................................................... 116

2.8.1. Cascade windows ...................................................................................................................... 116

2.8.2. Tile windows .............................................................................................................................. 117

2.8.3. Tile windows vertically ............................................................................................................... 117

2.8.4. Arrenge icons ............................................................................................................................ 118

2.9. Help ........................................................................................................................................................... 118

2.9.1. Version Information.................................................................................................................... 118

Chapter3 Frequently asked questions (FAQ) .................................................................................................... 119

3.1. Cannot communicate with inverter (Failed to get inverter information) ...................................................... 119

3.1.1. Message Manager not installed correctly .................................................................................. 119

3.1.2. USBriver not installed correctly .................................................................................................. 120

3.1.3. USB driver has been installed correctly, Loader cannot communicate ...................................... 120

3.1.4. USB communication impossible after the PC has gone standby or to sleep ............................. 121

Chapter4 Specifications .................................................................................................................................... 122

Page 6: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

iv

Page 7: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

5

Chapter1 Before Using FRENIC Loader

This chapter gives an overview of the inverter support software FRENIC Loader and provisions for its

installation and operation.

1.1. Overview

1.1.1. Features

・ Loader enables a PC to support remote operation of inverters either individually or

collectively via the RS-485 port on the inverters or the USB port on the TP-E1U(option).

・ Simplified operation of Loader allows you to easily manage and set the function code data

for the inverter.

・ Real-time trace allows you to monitor operation status of the inverters real-time in a graph

chart format with data lists, and to save the monitored result in a file that is useful to analyze

operation of a system configured with inverters.

1.1.2. Warranty

Limited

Warranty

In no event will Fuji Electric Co., Ltd. be held liable for any damage

(including, but not limited to lost profit, suspension or interruption of

operations, loss of operational data or other monetary loss) whatsoever

resulting from the use of the software or malfunction of the same or from

information contained in this document.

Page 8: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

6

1.2. Connecting Inverters to a PC

1.2.1. Connection

The table below lists the connection methods available for connecting inverters to a PC.

PC : Inverters On PC On inverter Connection

1 : 1

USB TP-E1U

(Option) Using a USB cable

USB RS-485 Via a USB / RS-485 converter

COM port

(RS-232C) RS-485 Via an RS-232C / RS-485 converter

1 : n

USB RS-485 Via an RS-232C / RS-485 converter

COM port

(RS-232C) RS-485 Via an RS-232C / RS-485 converter

1) For details about the RS-232C / RS-485 converter and USB / RS-485

converter, refer to “1.2.2.2Communications support devices for RS-485”.

2) To minimize the effects of noise, separate the signal lines from the power lines.

Refer to ”1.2.2.3Noise suppression”.

3) The inverter cannot be concurrently shared by the Loader-running PC and

other host equipment (e.g., PLC). To use Loader, therefore, be sure to

disconnect the cables of other host equipment from the RS-485 port on the

inverter.

4) For multi-drop connection of inverters, assign different station addresses to

each of the inverters connected.

• Be sure to turn off the power to the inverters and related devices before making

RS-485 connection.

Risk of electric shock if this warning is not heeded.

Page 9: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

7

1.2.2. Configuring an RS-485 communications network

1.2.2.1. Example of networking

To configure an RS-485 communications network connecting inverters and a Loader-running

PC, use a Shielded twisted pair cable for long distance transmission. (See below.)

Figure 1.1 Multi-drop Connection Diagram (Connecting to the Terminal Block)

・ When selecting communications support devices that protect parts on the printed

circuit boards of inverters from damage or malfunction due to external electrical

noiseor to keep the network in high noise immunity level, carefully read through the

descriptions in Section 1.2.2.2 "Communications support devices for RS-485".

FRENIC Loader

USB or RS-232C

TXD RXD

USB - RS-485 converter

or

RS-232C - RS-485 converter

Off-the-shelf one

TRD+

TRD-

FG

FRENIC Lift series

Inverter 1

DX+

DX-

FRENIC Lift series

Inverter 2

DX+

DX-

FRENIC Lift series

Inverter n

DX+

DX-

Shield

Station No.02

Using the built-in

terminating resistor

Switching terminating resistors

SW4=ON

112Ω

(2-wire)

(2-wire)

(2-wire)

Station No.01

Station No.n

Up to 31

inverters

Page 10: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

8

1.2.2.2. Communications support devices for RS-485

It describes the equipment required to connect a personal computer that does not include an

RS-485 interface.

[ 1 ] Converter

Usually PCs are not equipped with an RS-485 communications port but with an RS-232C port.

To connect inverters to a PC, therefore, you need an RS-232C–RS-485 converter or a

USB–RS-485 converter. To run the FRENIC-HVAC correctly, use a converter satisfying the

requirements given below.

Recommended converter spec

Send/receive switching: Auto-switching by monitoring of send/receive data status at the PC (RS-232C)

Electric isolation: Electrically isolated from the RS-485 port

Fail-safe: Fail-safe facility*

Other requirements: Superior noise immunity

* The fail-safe facility refers to a feature that ensures the RS-485 receiver's output at "High"

(logical value = 0) even if the RS-485 receiver's input is opened or short-circuited or all the

RS-485 drivers are inactive.

Recommended converter

System Sacom Sales Corporation (Japan) :KS-485PTI (RS-232C - RS-485 converter)

:USB-485I RJ45-T4P (USB - RS-485 converter)

[ 2 ] Cable

To ensure the reliability of connection, use twisted pair shield cables for long distance

transmission AWG 16 to 26.

Recommended LAN cable

Manufacturer: FURUKAWA Electric Co., Ltd.

AWM2789 Cable for long distance connection

Type (Product code): DC23225-2PB

Page 11: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

9

1.2.2.3. Noise suppression

Depending on the operating environment, instruments may malfunction due to the noise

generated by the inverter. Possible measures to prevent such malfunction are: separating the

wiring, use of shielded cable, isolating the power supply, and adding an inductance component.

Show below is an example of adding an inductance component.

Adding inductance components

To suppress or eliminate noise for keeping the network in high noise immunity level, insert

inductance components such as choke coils in series in the signal circuit, or pass the RS-485

communications cable through a ferrite core ring or wind it around by 2 or 3 turns as shown

below to keep the impedance of the signal lines high.

Figure 1.2 Adding an Inductance Component

Page 12: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

10

1.2.3. Configuring USB network

1.2.3.1. Example of networking

There is also a way to connect the inverter and the PC loader via USB. This requires TP-E1U

(optional). Connection cable, use a commercially available USB cable (mini-B connector).

(See below.)

PC

FRENIC-Lift

USB cable

USB cable

(mini A connector)

TP-E1U

(Option)

USB cable

(mini B connector)

Figure 1.3 USB Network Using a USB Cable (mini B)

Table 1.1 Specifications of USB Network

Specifications USB 1.1 compliant

Transmission speed 12M bps

Wiring length Max. 5 m

Connector USB mini B connector

・ Need to install the USB driver to your PC. Please refer to 1.3.1.3Installing USB

driver” for the installation method.

・ When connecting the inverter to a PC via the USB port, be sure to connect them,

one to one. Do not use a USB hub.

・ Refer to “1 .4 .4Communication Settings”, you must make the communication

settings.

Page 13: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

11

1.3. Installation

1.3.1. Installing software

Before installation

Execute the following before installation.

Check items Requirements

Windows OS Windows Vista (32/64-bit), Windows 7 (32/64-bit)

Other applications Terminate all the applications being in execution.

Uninstalling older version If a previous version of FRENIC Loader is installed, please uninstall.

Uninstall the message manager of the old loader

If the message manager of the old loader is installed, please uninstall.

・To use FRENIC Loader, you need to install two setup files: the loader software main

program [FRENIC Loader4__setup.exe*1

] and the message manager

[MsgMgr USB Setup.exe] that manages communications

*1 □□□□ indicates the version.

・To install the loader software, install with an account that has sufficient authority to install the

software.

Page 14: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

12

1.3.1.1. Installing loader

Follow the wizard and install Loader as shown below.

Double-click the FRENIC

Loader4_ setup.exe icon.

The exe automatically starts the

installation wizard.

To continue, click Next.

Carefully read the license agreement.

To view the entire contents of the

agreement, scroll the screen up and

down using the Page Up/Down keys

or the scroll bar.

If you agree, click Next to proceed.

Page 15: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

13

Enter your user name and company

name.

After entry, click Next to proceed.

Select the destination folder to

install. A default folder has appeared.

In the case of OS drive is “C”, a default

folder is “C:¥¥Fujielectric¥FRENIC

Loader4”.

To select a different folder, click

Change….

Click Next to proceed.

The screen confirming your selection

appears.

If you want to change the selection,

click Back to return to the previous

screen.

Click Install to proceed.

Page 16: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

14

To continue, click Yes.

Upon completion of the installation,

the screen at left appears.

Click Finish.

Page 17: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

15

1.3.1.2. Installing Message Manager

Follow the wizard and install Message Manager as shown below.

Double-click the MsgMgr USB E

Setup.exe icon.

The exe automatically starts the

installation wizard.

To continue, click Yes.

To continue, click Next.

Page 18: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

16

Carefully read the license agreement.

To view the entire contents of the

agreement, scroll the screen up and

down using the Page Up/Down keys

or the scroll bar.

Click Yes to proceed.

Select the destination folder to

install. A default folder has appeared.

In the case of OS drive is “C”, a default

folder is “C:¥Program Files

¥Common Files¥Fuji Electric

Shared¥Message Manager”.

To select a different folder, click

Browse…

Click Next to proceed.

Select the start menu folder that the shortcut to FRENIC Loader is to be added to.

You can select one from existing

folders in the list or create a new

one.

After entry, click Next to proceed.

The screen confirming your selection

appears.

If you want to change the selection,

click Back to return to the previous

screen.

Click Next to proceed.

Page 19: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

17

Upon completion of the installation,

the screen at left appears.

Click Finish.

Page 20: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

18

1.3.1.3. Installing USB driver

Using the USB interface for accessing the inverter(s) requires installing the USB driver to your

PC. The driver installation is required only once at the first use of the USB interface.

・If the USB driver has not been installed correctly, no communication via the USB

interface is possible.

First of all, connect the USB connector (A) on the PC and the USB connector (mini B) on the

inverter's keypad with each other using a USB cable.

・Before installation of the USB driver, install Loader and Message Manager.

When the OS finds a USB device of the Loader, it displays the following.

The system-supplied driver setup wizard does not run automatically. Install the USB driver as

shown below.

From the Start menu, select and

right-click Computer to show the

submenu.

Click Properties.

Left-Click

Wait for the Control Panel Home

screen and click Device Manager.

Page 21: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

19

On the Device Manager window,

right-click Unknown device to show

the drop-down

Click Update Driver Software….

Click Browse my computer for

driver software.

Page 22: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

20

Click Browse….

In the folder in which FRENIC-

Loader has been installed, select

¥Driver¥MICREXSX and then click

OK.

The default folder is C:¥Program Files

¥Fuji Electric¥FRENIC_Lift Loader

¥Driver¥MICREXSX when the OS

drive is C.

To continue, click Next.

Page 23: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

21

Click Install this driver software

anyway.

Start the installation.

Upon completion of the installation,

the screen at left appears.

To exit the installation wizard and

return to Windows, click Close.

Page 24: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

22

1.3.1.4. Checking the installation of the USB driver

To check whether the USB driver has been installed correctly, open “Device Manager”. If

“FRENIC” is added to the sub-tree of Loader USB device, the driver has been installed

correctly.

Installation finished successfully Installation failed

Page 25: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

23

1.3.2. Uninstallation

1.3.2.1. Uninstalling FRENIC Loader

From the Start menu, select All Programs | fujielectric | FRENIC Loader4 | FRENIC Loader4

Uninstall.

The confirmation screen at left appears.

Click Yes.

The confirmation screen at left

appears.

Click Yes.

The uninstallation progress bar

appears.

To abort the uninstallation, click

Cancel.

In the above procedure, perform the uninstallation.

Page 26: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

24

1.3.2.2. Before uninstalling Message Manager

Before uninstalling Message Manager, be sure to quit both Loader and Message Manager.

・Quitting Message Manager

Message Manager is software that manages communication between the PC and

inverters. To make sure that Message Manager has quitted, check that no Message

Manager icon is displayed in the task tray. If the icon is displayed, right-click it to quit

Message Manager. If doing so cannot quit it, shut down or log off Windows.

・Once you uninstall Loader when Message Manager is running, a new version of

Loader installed after that cannot run properly, that is, it may no longer be able to

recognize inverters. If this happens, first delete the folder (including its contents)

named Fuji Electric Shared in the file path as shown below, and then reinstall

Loader.

C:¥Program Files¥Common Files¥Fuji Electric Shared

(In the file path shown above, "C" represents the drive letter of the partition or hard

disk where Windows is installed. If Windows is installed on a different drive in your

system, replace "C" with the letter corresponding to that drive.)

・Quitting Message Manager

Click this to display the hidden icons as shown below.

Right-click this icon to display Exit MessageManager, then click it. The confirmation

window appears. Click Yes to quit Message Manager.

There are times when an icon is displayed here.

Page 27: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

25

1.3.2.3. Uninstalling Message Manager

From the Start menu, select All Programs | Message Manager | Message Manager

Uninstall.

The confirmation screen at left appears.

To continue, click Yes.

The confirmation screen at left

appears.

To continue the uninstallation

procedure, click Yes.

In the above procedure, perform the uninstallation.

Page 28: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

26

When it is ready to restart, click

Finish.

1.4. Configuring the Settings for Inverter(s) and Loader

1.4.1. Configuring communication-related function codes in the

inverter

The table below lists inverter's function codes related to Loader. Configure those codes before

connecting Loader to the inverter

Function code

Name Setting range Factory default

y01,y11 Station address 1~255 1

y04,y14 Baud rate

0:2400 bps

2:9600 bps

4:38400 bps

1:4800 bps

3:19200 bps 3

y10,y20 Protocol

0:Modbus RTU protocol

1:FRENIC Loader protocol (SX protocol)

2:Reserved

5:DCP protocol

y10: 1

y20: 0

y01,y11:Station address

Set the y01/y11 data to the same value as the RS-485 No. setting made in Loader's

Device connection list.

Refer to “1.4.5Connection settings”.

y04,y14:Baud rate

Set the y04/y14 data to the same value as the baud rate setting of communication

settings of the PC loader.

y10,y20:Protocol

Set the y10/y20 data to "1" (FRENIC Loader protocol).

Page 29: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

27

1.4.2. Checking the COM port on the PC (when using a

communications level converter)

Loader running on the PC uses the RS-232C communications port (COM) to interface with

inverters.

When an RS-232C / RS-485 converter is connected to the PC, check what COM port number

(COM#) on the PC is assigned to the RS-232C / RS-485 converter.

To use the USB interface, select a USB / RS-485 converter that functions as a virtual

RS-232C communications port (COM). When a USB / RS-485 converter is connected,

Windows automatically assigns a free COM port on the PC to the converter. To check the

assignment, follow the procedure below.

From the Start menu, select Control Panel | Hardware and Sound | Device Manager.

Click + preceding Ports (COM &

LPT) to show details.

Check the number "n" in USB Serial

Port (COMn).

This example shows that COM3 is

assigned to the USB Serial Port.

Page 30: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

28

1.4.3. Configuring Loader

When Loader has been installed on your PC, selecting All Programs | FRENIC Loader4 |

FRENIC Loader4 Start from the Start menu starts Loader.

Page 31: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

29

If Loader starts, the Quick Access Menu first appears as shown below.

This menu contains the 8 quick-start icons for the programs contained in Loader. To start a

program, simply click the corresponding icon (Schedule operation and Test running can not be

used).

Details of the programs are described in Chapter 2.

When using Loader for the first time or after having changed the supporting inverter(s), you

need to configure the operating environment by setting up the communications parameters

(COM Setting).

Click the COM Setting icon to open the Communication Setting dialog or Device connection list

window.

・If the Quick Access Menu is not displayed, click the icon on the toolbar (shown

below) at the bottom of the Loader top window to open the menu.

Configures

communications

parameters

Page 32: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

30

1.4.4. Communication Settings

Click [COM.Setting.] icon in the left row in Simple Menu to display the screen which sets the

methods to connect the loader, targets to be connected and communication conditions. Enter

the data by referring to the following descriptions. Alternatively, by selecting Setup |

Communication Settings from Main Menu, you can display the communication setting screen

without using Simple Menu.

[ 1 ] Connection Methods

Select the method to connect the loader.

Connect Loader Directly to Inverter

Select this method when connecting your PC to the inverter directly, not via MICREX-SX

Controller.

(You can select one of the two communication types: RS485 or USB.)

Page 33: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

31

[ 2 ] Port

You can do settings on communications. (In the initial status, you can establish communications

without changing any setting because the PC initial settings are well matched with those of the

inverter.)

RS-485

Select this method when connecting your PC to the inverter via RS-485.

・Port setting

Choose the PC communication port to which you connected the USB - RS-485 converter /

RS-232C - RS-485 converter.

・Baud rate

Set the transmission rate. You must select the transmission rate same as the one for the

inverter.

・Flow control

Since the recommended converter manages the flow control by automatic switching

through transmission data monitoring, you do not have to change this setting. The flow

control is a method that uses RS-232C control signals to control RS-485

transmission/reception switching.

・Data length

Set the data length per frame. However, regardless of the setting is fixed to "8bit".

・Parity

Set the parity type. However, regardless of the setting is fixed to "Even".

・Stop bit

Set the stop bit length per frame. However, regardless of the setting is fixed to "1bit".

USB connection

Select if you want to connect a personal computer and an inverter with a USB cable via

the TP-E1U (option).

Please select the "Data in Inverter (via Keypad)".

Page 34: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

32

[ 3 ] Communication Conditions

Do the settings on the communication retry.

・Retry count

This sets how many times communication allows retry in case of failure. As the retry count

increases, the possibility to succeed communications may increase. However, it will take

time until the error dialog appears. The count of one or so is recommended.

・Time out

If no response is received from the inverter within the time limit set here, the communication

error dialog will open. A shorter timeout setting allows sooner display of the error dialog.

However, an extremely short timeout may cause a communication error even during normal

operation, for example, when taking long time to handle the inverter rather than the

communication errors.

[ 4 ] Perform Connection Check

Connection Check is a function to always monitor the communication status between your PC

and the inverter that is registered through the connection settings. By clicking the check box to

the left of [Perform Connection Check] and checking the box, the PC will automatically check

the status of connection with the inverter and displays the communication status on the status

bar. If one of the previously registered inverters disables to communicate due to disconnection

or other problem, the response performance will become very slow. Be sure to remove the

disabled inverter from the connection settings.

Page 35: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter1 Before Using FRENIC Loader

33

1.4.5. Connection settings

Click COM setting | Connection Setting to display the Connection Settings screen.

[ 1 ] For connection to RS-485 port

RS-485 connection

The Device connection list window shows the inverters available for RS-485 communication.

Double-clicking (or use the Advance… button) the row where the inverter to be modified or

added is listed calls up Advanced dialog shown below.

Selection of inverters to be monitored

To make an inverter enable to be monitored, put a check

mark (✓) in the box located

at the left end column of the list.

Delete

Clicking the row to be deleted and clicking this Delete button deletes the inverter listed in that

row. Use this for the inverter(s) that has been disconnected from Loader.

Browse

Clicking this button checks whether a link between Loader and the inverter(s) (marked with

✓) is established. The result appears in the Status column.

Status column

- Unknown

- Connecting

- Disconnected

: The communications status has been unknown.

: The communications link has been established.

: The communications link has not yet been established.

Advance

Clicking the row to be modified or added and clicking this Advance button calls up the Advanced dialog shown at the right.

Fill in the Equipment name and RS-485 address (station address

*) boxes in the

dialog and click OK. To cancel your entry or selection, click Cancel.

* According to Channel to use of RS485,

please set it as follows.

RS-485 Ch1 : y01

RS-485 Ch2 : y11

After completion of data entry, check the settings again and click OK to exit the device

connection operation.

Page 36: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

34

[ 2 ] For connection to USB(via TP-E1U)

USB(via TP-E1U): Data in inverter

Only a single line appears as shown below. After making sure that the equipment name and

RS-485 num. (station address) are correct, click the Browse button to monitor the current

communications link status.

Selection of inverters to be monitored

To make an inverter enable

to be monitored, put a

check mark (✓) in the box

located at the left end

column of the list.

Browse

Clicking this button checks

whether a link between

Loader and the inverter is

established. The result

appears in the Status

column.

Status column

- Unknown

- Connecting

- Disconnected

: The communications status has been unknown.

: The communications link has been established.

: The communications link has not yet been established.

Advance

Clicking the row to be modified and clicking this Advance button calls up the Advanced

dialog shown at the right.

Fill in the Equipment name and a station address

* boxes in the dialog and click OK.

To cancel your entry or selection, click Cancel.

* According to Channel to use of USB,

please set y01.

After completion of data entry, check the settings again and click OK to exit the device

connection operation.

Page 37: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

35

Chapter2 Description of Functions 2.1. Main Window

Main Window is the first screen appearing after starting the loader. Simple Menu is displayed on

Main Window. (The following example omits the display.)

Main Menu

You can select all the Loader functions.

Tool Bar

You can select primary Loader functions.

Status Bar

This shows the outline of the function to be selected. It

also displays the status of connection with the inverter

inthe upper right box.

Main Menu

It contains six selectable functions: [File], [Menu], [Setup], [View], [Window] and [Help].

Tool Bar

This allows you to select common functions quickly and easily. For example, to open a file

which contains the function code data, you should normally click [File] on Main Menu and then

click [Open] under [File] menu; accordingly two actions are required. Using Tool Bar, you can

open the file simply by clicking icon.

Status Bar

Place the mouse pointer on the function icon or menu being displayed. Then, the statement

appears, describing the meaning of the function or menu.

When “Perform Connection Check” is selected in Communication Setting (refer to “1.4.3

Configuring Loader”), the status of connection with the inverter is displayed in the upper right

box. (In the above example, “Unknown” is displayed.)

Page 38: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

36

2.2. File

This section describes main functions of File.

2.2.1. Create New File

This function creates a new file of function code data.

Model selection pull- down menu

Select the format of the model.

Area Specification

Select the specification by area.

Inverter voltage

Choose the inverter voltage.

Inverter capacity.

Choose the inverter capacity.

You can also open a list of function code data defaulted by the loader. Therefore, you can edit

the function code data even if the inverter is not connected to your PC.

2.2.2. Open

This function reads a file of Function code data, Realtime trace data or Historical trace data,

Customizable logic data that has been already created and saved in your PC and opens the

window to edit the file data.

Open

This button opens the selected

file.

File type

・Function code data :「*.FNL」

・Realtime trace data :「*.RT1」

・Historical trace data :「*.HT1」

・Customizable logic data :「*.CML」

2.2.3. Close

This function closes the active window.

Page 39: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

37

2.2.4. Save

This function overwrites and saves the active function code setting. If the data has not been

saved before, the Save function does the same operation for the data as “5) Save As…”.

2.2.5. Save As…

This function opens the following dialog, which allows you to enter the name of the active file

and save it under the name.

* The types of files you can save are as below:

・Function code data :「*.FNL」

・Realtime trace data :「*.RT1」

・Historical trace data :「*.HT1」

・Comma delimiter :「*.CSV」

・trace data (Graph image) :「*.JPG」

2.2.6. Print

This function specifies the printer, property, print range and number of copies to be printed.

Printer Name

Select printer that can

be used.

Property

Detailed settings for the

selected printer-specific.

Print range

Set the page range.

Print copies

Set the number of

copies.

OK

Click the “OK” and

printing is started.

Page 40: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

38

2.2.7. Print Preview

This function displays the print preview of the printable data of the active window (function code

setting list or trace window).

2.2.8. Page Setup

Make settings for the paper.

2.2.9. End

This function terminates the loader.

Page 41: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

39

2.3. Menu

You can select Function Code Setting or Simple Menu Function.

2.3.1. Function Code Setting

Select from the toolbar of the main window, When clicked [Setting function code], opens

[Edit data selection] dialog. Also when you click on the Menu | Function code edit opens

[Select function code data to edit] dialog.

From the [Select function code data to edit] dialog, choose the read item.

2.3.1.1. Open the customizable logic setting window

If put a check mark (✓ ) in the box, customizable logic setting window opens.

2.3.1.2. Create New Function Setting

Use this function to open a new function code setting.

Refer to “2.2.1Create New File”.

2.3.1.3. Read File from the PC

Use this function to open the function code setting file which has been previously saved.

Refer to “2.2.2Open”.

2.3.1.4. Read from the Inverter

Use this function to read the function code setting from the connected inverter and open the

function code setting.

2.3.1.5. Edit List

This function allows you to list the function code setting values and setting ranges and edit

Page 42: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

40

them.

You can display the function codes by various classifications. [Edit] menu on Menu Bar is

displayed only when the Edit List window opens.

・Function :Display the function codes by group.

・Change from

Factory-set Values

:Displays the function codes of the setting

values daifferent from the factory-set values (excluding communication codes).

・Contents of

change (Blue)

:Displays the edited function codes before

written to the inverter.

・R/W failure (Pink) :Displays the function codes which have failed

to write to the inverter.

Change of Setting Values:

You can select the function code data from Drop down Menu or Edit Window.

・User Definition :The user can freely define the display items.

・Communication Code :Displays communication function codes only.

・Comparison Result :Displays comparison results with the inverter

or saved files only.

・Search Result :Displays the execution result of [Edit] ->

[Search].

[Read]

:Reads the function codes of the inverter

selected in [Target Inverter] to the loader. [Target Inverter]:

Selects the target inverter to/from which data is read/written.

[Close]:

Closes the Function Code Setting window.

[Write]

: Write the function codes of the loader to the

inverter selected in [Target Inverter].

[Factory-set]

: Resets the selected function code to the

factory-set value.

[Func. Code set]

: Displays a dialog to edit the selected

function code setting values.

[Function code info] : Displays the selected function code information.

[Initialize] : Initializes the function code setting values within the inverter.

[Advanced] : Displays a dialog to change the display items, function code attributes

and printing setting.

[Print] : Prints the function code list selected in the tree in the left pane.

[Comparison] : Displays the comparison results with the saved data or the inverter data.

Page 43: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

41

[ 1 ] Read the function code setting values from the inverter

When you want to update the function code setting values read from the inverter

Click [Read] button to open the following dialog. Click [OK] to read the function code setting

values from the inverter again.

[ 2 ] Write the function codes from the loader to the inverter

To write the function codes to the inverter, use [Write] button displayed at the lower bottom of

the List Edit window appearing when editing function codes.

・Editing function code data (blue part) only

This function writes to the inverter only the setting values of the function codes that are

edited by the loader and have not been written to the inverter yet (displayed in blue).

・Registered user definition function code data only

This function writes only the setting values of the function codes registered to the user

definition on the List Edit window.

Page 44: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

42

・Different from the factory function code data (with *) only

This function writes the setting values to the inverter only when those of function codes are

different from the factory-set values (excluding communication codes).

・All function code data

This function writes all the function code setting values in the table (excluding

communication codes).

・Write function code to the EEPROM (Write 2 to y97)

After writing function code data, the settings are stored to EEPROM in the inverter. At the

condition that y97 is written, y97 setting is also stored in EEPROM.

・Writefunction code following y97 setting (Do not write y97 function code.)

After writing function code data, it is determined depending on y97 of inverter whether

store the data to EEPROM. Regardless of the writing method, y97 setting is not written.

communication codes

Page 45: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

43

[ 3 ] Change the setting value

The method to change the setting values varies depending on the function code.

(1) For the function codes which set speed, time, voltage or other numeric values,

double-click the field of the function code setting value to be changed. When [Set Values]

dialog appears, set the new value.

(2) For the function codes which set the code data values (for example, F00 Data Protection,

F01 Speed setting N1, F02 Operation method), click the field of the function code setting

value to be changed to check that button appears. Click the button to display the

selection menu which lists the function data that can be set and the meaning of each

function.

・ When the changed function code data has not been written to the inverter yet, the

data is displayed in blue.

・ When the changed function code data is different from the factory-set values, it is

marked with * leftmost on the Edit List window.

Page 46: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

44

[ 4 ] Save

To save the function code settings opening on the loader, select [File] -> [Save] or [Save As …]

from Main Menu.

When selecting [Save] for the data for the first time, the following dialog will open in the same

manner as when selecting [Save As …].

Select [Save to …] and enter the file name under which the data is saved in [File Name]. Click

[Save] and confirm the entry.

*.FNL : File format specific to the loader. Files in this format can be opened only on the FRENIC

Loader.

*.CSV : Comma delimiter format. Files in this format can be opened on Microsoft Excel or

equivalent. However, they cannot be opened on the general-purpose inverter loader.

*.FBL : Function code setting data format. Files in this format can be opened only on the

FRENIC Loader.

Page 47: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

45

[ 5 ] Print

The items selected from the tree in the left pane on the Edit List tab are target to be printed.

When selecting “Function” or “Code group” from the tree in the left pane on the Edit List tab,

function codes such as F, E, C, … or the group name will appear.

Click [Print] button displayed at the lower right of the [Edit List] window or select [File] -> [Print]

from Main Menu to display [Print] window.

Set the printer to be used, printing range and number of copies and click [OK] button.

How to set simple printing

To print only the function code numbers and setting values from among the items in the Edit

List window, click [Detail Setting] at the bottom of that window to open the Detail Setting dialog

and click [Print Setting]. When the [Print Setting] dialog appears, check the box of [Simple

Printing] and click [OK]. Note that this operation determines the setting only and does not

actually print the setting.

How to check the printed appearance before actually printing

Select [File] -> [Print Preview] from Main Menu.

Page 48: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

46

[ 6 ] Compare

You can compare the function code setting data being edited to the data saved in the file or the

data set in the inverter that is selected in [Target Inverter] and display the results.

Compared with inverter

Compare the function code setting data being edited to the function code setting data in the inverter.

Compared with File

Compare the function code setting data being edited to the function code setting data saved in the file.

Comparison results include ReadOnly

By marking the check BOX, ReadOnly function codes are included in the comparison target.

Comparison results include Communication code By marking the check BOX, “communication code” function codes are included in the comparison target.

Close

Close the Select Comparison Target dialog.

* You should select the inverters to be compared in advance by clicking of [Select Inverter]

displayed at the bottom of the [Edit List] window.

By selecting “Comparison Results” in the tree in [Edit List], you can check the same contents.

Page 49: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

47

[ 7 ] User Definition (Display desired function codes only)

Select the function code from the Edit List window and right-click it to display the window

related to “User Definition”. Select one of User Definition 1 to 5 and left-click it to register the

selected function code to “User Definition”.

Select any one of User Definition 1 to 5 from the tree in the left pane of the Edit List tab. Then,

the registered function codes will be listed.

Page 50: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

48

To unregister the function code, select the target one and right-click it to display the window

related to “User Definition”. Then, select Reset User Definition and left-click it to unregister the

target function code from “User Definition”.

To unregister the function code from all the user definition groups (1 to 5), select “Relese User

Definition” and left-click it. Then, the function code will be unregistered from all the user

definition groups.

Page 51: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

49

[ 8 ] Search (Search function code terminologically)

Select [Edit] -> [Search] from Main Menu to display [Search] dialog.

From among words on the Edit List window, enter the key word to be searched, for example, speed or gain, and click [OK] button. If the entry is correct, the program automatically moves to [Search Results] in the tree in the left pane of the Edit List tab and the function codes including the entered key word are listed. The following figure shows the example of search results with “Speed” and “Gain” as the key word.

・The search target range covers all items (changes, No., function code names,

setting values, etc.) However, the items set to be “hidden” by [Advanced] -> [Display Item] are also included in the search target.

・The contents of function code information are not included in the search target.

Page 52: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

50

2.3.1.6. Auto Tuning

This function automatically measures the motor constants and saves them to the inverter as

parameters of Motor 1.

Select tuning operation

0 : Disable.

1 : Tune %R1 and %X while the motor is stopped.

2 : Tune %R1, %X, no-load current, and rated slip while the motor is stopped.

3 : Tune %R1, %X, and rated slip while the motor is stopped. And calculate no-load

current.

Current Process

Display the tuning progression status.

Tuning Results

Read the values before and after tuning and display them.

Target Motor

Display Motor 1 (M1),

Select Tuning Operation

Select which motor constant is to be tuned.

Select Inverter

Select the tuning target inverter.

Auto Tuning

Start the tuning operation.

Motor Constant

Read the motor constant set in the target inverter and display it.

Page 53: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

51

2.3.1.7. File Information

This function displays the information which may affect the function codes. You can change

“Type”, “Voltage”, “Capacity” and “Definition File” as you want.

・When reading the information codes from the inverter, the information on that inverter is

displayed.

・When creating a new code, the default information by machine type is displayed.

・You can save the necessary information as a comment.

When clicking on the file information [Change] button, the Settings dialog is displayed.

Page 54: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

52

[ 1 ] Changing the input power supply voltage

You can change the input power supply voltage of the inverter whose function code data is

currently listed in the Function code edit window.

・Changing the voltage automatically modifies the factory default, minimum, and

maximum values of function codes.

[ 2 ] Change of inverter capacity

Change the "capacity inverter" of the current function code list.

・It will be changed into the value of the capacity as which the "preset value" of the

following function code and the "factory-shipments value" were chosen if "Inverter

capacity" is changed.

Page 55: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

53

Function

code Name

Function code

Name

F05 Rated Voltage at Base Speed P03 Motor (Rated current)

F09 Torque boost 1 P06 Motor (No-load current)

F11

Electronic Thermal Overload Protection for Motor (Overload detection level)

P07 Motor (%R1)

F12

Electronic Thermal Overload Protection for Motor (Thermal time constant)

P08 Motor (%X)

E34 Current Detection 1 (Level 1) H98 Protection/Maintenance Function

E37 Current Detection 2 (Level 2) L125 UPS/batteries minimum operation level

P02 Motor (Rated capacity)

[ 3 ] Change of definition file

“Definition file” of the function code list is corresponded to software version (ROM No.) of the

inverter. It can be checked by using keypad (TP-E1U, or TP-A1-LM2).

On the loader software, it is shown in “System monitor” tab on “Operation monitor”, or function

code M25 on the function code list after reading from the inverter.

Page 56: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

54

When changing the "definition file" of the current function code list, click [change] button and

displays the dialog "Open file."

Select the definition file that corresponds to the ROM version of the inverter, and then click the

[Open] button.

To below as the "definition file" and "inverter ROM version" shows the relationship.

Inverter ROM version Definition file

300 fnc_E_LM_2_0300*.csv

400 fnc_E_LM_2_0400*.csv

500 fnc_E_LM_2_0500*.csv

・Alphabet letter might be placed to “*”.

・It might be added more files that above according to version of the loader.

Page 57: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

55

Definition file name (FRENIC-Lift(LM2))

Is present in the pre-change definition file,function code that does not exist in the definition file

after the change, will be displayed in the dialog of the file read error.

・After changing the definition file, the setting of function code other than an error

reading the file is transferred intact.

・Error function code that does not exist, it will be removed because they are not used.

fnc_x_LM_2_□□□□○.csv

ROM version that the definition file supports .

Destination (E : English, None : Japanese)

Model

Alphabet letter might be placed to the end according to revision.

Page 58: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

56

2.3.2. Operation monitor

Monitor the running status of the inverter.

Select from the toolbar of the main window, When clicked [Operation monitor], opens

[Operation monitor] window. Also when you click on the Menu | Operation monitor opens

[Operation monitor] dialog.

2.3.2.1. I/O monitor (for control terminal input/output signal status of

the inverter)

Monitor the state of the input terminal and the output terminal of the inverter.

Refresh

Refresh the "Terminal Function name" and

"Normal open or close".

CSV Save

Saves the I/O monitor data in CSV format.

Select inverter Selects the inverter to be monitored.

Changes the color of the terminal "state".

("Normal" and "status" if the same : Green, "Normal" and "status" if the different : Orange.)

Normal Status(Open) Status(Close)

Open Green Orange

Close Orange Green

Page 59: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

57

2.3.2.2. System monitor (for current setup info and maintenance info of

inverter)

The System monitor allows you to check the inverter ROM version, inverter type, current setup

information, and maintenance information of the selected inverter.

CSV Save

Saves the system monitor data in CSV format.

Select inverter

Selects the inverter to be monitored.

Page 60: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

58

2.3.2.3. Alarm monitor

The Alarm monitor shows the alarm status of the selected inverter. In this window, you can

check the content of the current alarm and the various running information recorded when the

alarm has occurred.

Alarm reset… Resets the alarm that

currently occurs.

Alarm reset…

Resets the alarm that

currently occurs.

Select the running info recorded

when an alarm has occurred

Selects the running information recorded when the alarm selected from the last 4 alarms has occurred in the inverter.

CSV Save

Saves the alarm data in CSV format.

Select inverter

Selects the inverter to be

monitored.

・Resetting an alarm with a run command being ON will cause the inverter to run the motor

unexpectedly. An accident or injury could occur

Page 61: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

59

2.3.2.4. Operation status monitor (Monitor the operation information of

the inverter)

You can check information such as current speed and output voltage.

CSV Save Saves the Operation status monitor data in CSV format.

Select inverter

Selects the inverter to be

monitored.

Page 62: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

60

2.3.3. Customizable logic function

By graphical editing tool create a logic circuit of customizable function, it can be transferred

to the inverter.

In addition, you can debug a circuit that was created on the screen.

2.3.3.1. Selecting Project

The following window (Project selection) appears first when the software is launched.

・Create

Creates a new customizable function project file.

Model selection tab

Select the format of the model.

Version selection tab

Select version.

Number of steps

Show the maximum number of steps.

・Loading file from PC

Loads a customizable function project file that has already been created and saved to the

PC, and then opens a window allowing the file data to be edited.

File type

Customizable function project data : [*.CML]

Page 63: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

61

2.3.3.2. Editor screen

Project management window

Manages project files and function

properties.

Execution cycle

Displays the cycle time of executing

customizable functions.

Update

Update the latest number of steps.

マイズ機能のシンボルを選択

します。行する サイクルタイ

ムを表示します。

Select Inverter

Inverter to be connected is selected.

Zoom in / out

Zoom in / out the layout window.

Grid

Change grid size.

マイズ機能のシンボルを選択

します。行する サイクルタイ

ムを表示します。

Clear log

Clear log of Message window.

Layout area

Draws functions with symbols added to

the layout area.

Message window

Displays information such as the results of

function code automatic assignment.

Toolbox

Selects function symbols used in the

layout.

Page 64: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

62

2.3.3.3. Customizable Function Creation Procedure

This section describes the customizable function editing procedure.

Symbol selection tab

This tab selects the function type group of

the symbol.

Symbol selection combo box

This combo box displays the type of the

symbol.

Common symbol

Input / Output

These symbols are used for input and

output terminals.

Branch

These symbols are used to branch lines.

Comment

These symbols are used to write

comments.

Function symbols

The function symbols selected in the tabs

and the combo box are displayed.

START

END

Design functions

Layout functions

Compile

Download to the inverter

Debug

Draw the logic functions in a

graphical editing tool.

Page 65: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

63

[ 1 ] Layout function symbols

Select symbols from the toolbox and drag and drop them onto the layout.

The execution order of the functions is determined by the layout position.

Refer to ”2.3.2.3 [5] Assigning Step Numbers”.

[ 2 ] Parameters of Function Symbols

Setting the parameters of the signal selection and timer values, etc. of the symbol can be set in

the dialog which appears when you double-click on the symbol.

Also the dialog appears when you select "Properties" from the context menu that appears when

you right-click to select the symbol.

Page 66: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

64

・Assign the terminal function

The Input / Output terminals are available to be assigned a specified function which an inverter

has.

・Set the parameters of Function symbol

Some function symbols have their setting parameters. In order to set them open the "Property"

window with a right-click.

Page 67: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

65

[ 3 ] Connecting Function symbols

In order to connect function to other, select a symbol and open the context menu with right-click.

And then select "Connection line" from the context menu that appears.

Wire connection appears. Put the cursor on the red box at the end of the wire connection, and

then move the red box to the target function symbol with holding down the left button.

When the connection is succeeded, the red box at the end of the wire connection changes to a

black box.

By releasing the left button, the black box at the end of the wire connection changes to a gray

circle, and connection is fixed.

Page 68: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

66

[ 4 ] Creating Function Blocks (FB)

A function block (FB) allows to integrate multiple function block symbols into one symbol.

In order to entry a function block (FB), select "FB (common)" in the tree view, right-click, and

then select "New" from the context menu that appears.

A dialog box for creating a new function block appears. Entry the necessary information and

click [OK].

Entry number of FB input.

・These parameters can be changed even after registration.

You can provide favorite name freely.

Entry number of FB input.

Entry number of FB output.

You can describe words freely.

Page 69: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

67

If you select the "FB001" added to project tree, double-click "FB001" on the tree, then

"FB001 *FB (common) Edit *" tab appears.

Page 70: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

68

To edit the internal function block of new function block, the following procedure is required.

(1) Entry Input/Output symbol.

(2) Assign the functions to the input/output symbols.

(3) Draw function blocks by using symbols from tool-box and connect them.

An example is shown below.

Entry input symbol and select "Function block input" → "Input1".

Entry output symbol and select "Function block output" → "Output1".

Page 71: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

69

After editing function block, select "FB (common)" in the tree view, right-click, and then select

"Save" from the context menu that appears.

If the function block (common) is succeeded to store, the function block symbol appears in the

toolbox "FB" tab.

・The stored function blocks (FBs) are available to be used as a template for other

projects.

Page 72: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

70

Return to the "Program00" sheet, select function block symbols from the toolbox, and then drag

and drop them onto the function block layout.

By laying out "FB001_1", "FB001_1" is added to the tree view under target project. By then

double-clicking, a tab for editing "FB001_1" appears.

・"FB001_1" is a copy of the template function block (common) "FB001" and it

belongs to the target project.

・The changes for this function block are not applied to template FB and vice versa.

Page 73: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

71

[ 5 ] Assigning Step Numbers

After function layout, you should assign each function symbol or FB to the step of the

customizable function. There are two methods for assignment and shown as follows.

・The execution order of functions are executed in the order of step number.

・Rules of number assignment

The basic rules of number assignment are as follows.

(1) The upper side of the layout area has higher priority than the lower side.

(2) The left side of the area has higher priority than the right side.

(3) The upper side has higher priority than the left side.

Show example in the following.

High

Low

Low

① ② ③

⑤ ⑥

Page 74: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

72

・Automatic Step No. Assignment (Function Check)

Automatic step number assignment can be executed after function circuit creation.

The step number will be assigned only if no errors have occurred during the function check.

The step numbers will be assigned even if "warning" occurs.

Page 75: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

73

If there is a problem with the connection or a conflict with the function assignment, an error will

occur and the step number can not be assigned.

When you double-click a warning or error message in the output window, you can jump on the

symbol display of the corresponding location.

Page 76: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

74

・Manual Step No. Assignment

Manual step number assignment is also available to execute after function circuit creation.

Select the symbols which you want to assign manually with right-click, and then select

"StepNo./Priority setting" from the context menu that appears.

There are two types of manual step number assignment.

User Assign → Step No. : Step number is specified directly by the user.

User Assign → Priority : Step number are assigned automatically, however, the

assignment priority is specified by the user.

The priority of step number assigmnent is shown as follows.

Automatic assignment < priority designation < direct step No. designation

・Even if you want to assign the step number manually , it is recommended that you

execute "step automatic number assignment" in order to check your function.

Page 77: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

75

You can check the assignment status on the "Step No. Assignment" window.

Page 78: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

76

2.3.3.4. Downloading to the Inverter

The edited function can be converted to the function setting for the inverter function codesafter

step number assignment and checking functions are successfully finished.

If the conversion is succesful, "Write" button becomes selectable.

In order to download these settings to the inverter, click the "Write" button.

・Before writing customizable logic function to the inverter, U code and U1 code is

once initialized. User settings code of U121 ~ U140 and U171 ~ U175, also because it is initialized, please save the settings as needed.

・If you write a customizable logic during startup,"ECL: Customizable logic error"

alarm occurs.

Page 79: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

77

2.3.3.5. Comparison

If the conversion was successful, "Compare" button will become selectable and the comparison

will be available.

In order to compare the current project with the function code settings of the inverter or with the

stored file, click either button.

The comparison results shows inverter function codes which does not match, and it also can be

saved in CSV format.

Page 80: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

78

The symbols which have a difference are also highlighted.

Page 81: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

79

2.3.3.6. Debug

[ 1 ] Online Monitor

The online monitoring is the function to monitor timer value or signals of a symbol as a

numerical value. The online monitor is available to select after downloading the created function

settings to the inverter or if the functions of the inverter are fully consistent with the functions of

the software under test. In order to monitor input / output and status of target symbol,select an

symbol with left-click and open the menu window, then select "Online monitor" from the

context menu with right-click.

Before starting the online monitor, it is necessary to activate the customizable logic function.

Page 82: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

80

After the customizable logic functions are executed in the inverter, monitor start button will be

available.

During monitoring, status of the input/output, logic symbol and function block can be checked

as blue letters on the layout area.

Below it will show a display example.

Digital input / output

0: OFF / 1: ON (If logic inversion 0: ON / 1: OFF)

Analog input / output

Display the analog value.

・Input / Output

・Symbol

Show the coefficient(1) and coefficient(2) to under

the symbol. Display the output data in the upper

right corner.

Show the ON / OFF under the function

name.

Page 83: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

81

・Function Block (FB)

Coefficient Name List

Monitor name Name Range

T.P Timer period 0.00~9990s

CNT Count 0.00~9990

U.L Upper Limit -9990~0~9990

L.L Lower Limit -9990~0~9990

1ST 1st Additional Value -9990~0~9990

2ND 2nd Additional Value -9990~0~9990

DEV Deviation -9990~0~9990

HYST Hysteresis Width -9990~0~9990

REF Reference Value -9990~0~9990

MAX Maximum Scale -9990~0~9990

MIN Minimum Scale -9990~0~9990

KA Factor KA -9990.0~+9990.0

KB Factor KB -9990.0~+9990.0

T.C(T/C) Time constant 0: No filter / 0.01~ 5.00s

FIX Fixed as 0

ACC ACC 0: No limit. 0.01~600s

DEC DEC 0: No limit. 0.01~600s

Gain Gain ratio 0~200%

Frq Lower frequency limit 0 to 500Hz

Val1 Set Value -9990~0~9990

Val2 Set Value2 -9990~0~9990

Step Step number 1~200

[ 2 ] Trace Mnitor

Trace monitor is the ability to monitor the timer value, or signal of the symbol as a waveform.

Refer to "2.3.4.9Combination of a customizable logic functions".

Display the output data in the upper right in the

function block(FB).

Page 84: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

82

2.3.3.7. List of Customizable function Symbols

Block selection

Symbol Function block Description

10

Through output This function is through output. No function block exists.

11

Through output + On-delay timer

Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

12

Through output + Off-delay timer

Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

13

Through output

+ One-shot pulse output) Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

14

Through output + Retriggerable timer

Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

15

Through output + Pulse train output

If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. This function is used to flash a

luminescent device.

20

Logical AND + Through output

AND function with 2 inputs and 1 output, plus through output.

21

Logical AND + Through output

AND function with 2 inputs and 1 output, plus Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

Page 85: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

83

Block selection

Symbol Function block Description

22

Logical AND + Off-delay timer

AND function with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

23

Logical AND + One-shot pulse output

AND function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

24

Logical AND + Retriggerable timer

AND function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

25

Logical AND + Pulse train output

AND function with 2 inputs and 1 output, plus If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. This function is used to flash a luminescent device.

30

Logical OR + Through output

OR function with 2 inputs and 1 output, plus

through output.

31

Logical OR + On-delay timer

OR function with 2 inputs and 1 output, plus Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

32

Logical OR + Off-delay timer

OR function with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

33

Logical OR + One-shot pulse output

OR function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

34

Logical OR + Retriggerable timer

OR function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

Page 86: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

84

Block selection

Symbol Function block Description

35

Logical OR + Pulse train output

OR function with 2 inputs and 1 output, plus If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. This function is used to flash a luminescent device.

40

Logical XOR + Through output

XOR function with 2 inputs and 1 output, plus

through output.

41

Logical XOR + On-delay timer

XOR function with 2 inputs and 1 output, plus Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

42

Logical XOR + Off-delay timer

XOR function with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

43

Logical XOR + One-shot pulse output

XOR function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

44

Logical XOR + Retriggerable timer

XOR function with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

45

Logical XOR + Pulse train output

XOR function with 2 inputs and 1 output, plus If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. This function is used to flash a luminescent device.

50

Set priority flip-flop + Through output

Set priority flip-flop with 2 inputs and 1 output,

plus through output.

51

Set priority flip-flop + On-delay timer

Set priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

Page 87: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

85

Block selection

Symbol Function block Description

52

Set priority flip-flop + Off-delay timer

Set priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

53

Set priority flip-flop + One-shot pulse output

Set priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

54

Set priority flip-flop + Retriggerable timer

Set priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

55

Set priority flip-flop + Pulse train output

Set priority flip-flop with 2 inputs and 1 output, plus If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. This function is used to flash a luminescent device.

60

Reset priority flip-flop + Through output

Reset priority flip-flop with 2 inputs and 1

output, plus through output.

61

Reset priority flip-flop + On-delay timer

Reset priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON starts the on-delay timer. When the period specified by the timer has elapsed, an output signal turns ON. Turning the input signal OFF turns the output signal OFF.

62

Reset priority flip-flop + Off-delay timer

Reset priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

63

Reset priority flip-flop + One-shot pulse output

Reset priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

64

Reset priority flip-flop + Retriggerable timer

Reset priority flip-flop with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

Page 88: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

86

Block selection

Symbol Function block Description

65

Reset priority flip-flop + Pulse train output

Reset priority flip-flop with 2 inputs and 1 output, plus If an input signal turns ON, the function block issues ON and OFF pulses (whose lengths are specified by the timer) alternately and repeatedly. For example, this function is used to flash a luminescent device.

70

Rising edge detector + Through output

Rising edge detector with 1 input and 1 output, plus general-purpose timer. This detects the rising edge of an input signal and outputs the ON signal for 5 ms.

72

Rising edge detector + Off-delay timer

Rising edge detector with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

73

Rising edge detector + One-shot pulse output

Rising edge detector with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

80

Falling edge detector + Through output

Falling edge detector with 1 input and 1 output, plus general-purpose timer. This detects the falling edge of an input signal and outputs the ON signal for 5 ms.

82

Falling edge detector + Off-delay timer

Falling edge detector with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

83

Falling edge detector + One-shot pulse output

Falling edge detector with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

90

Rising & falling edges detector + Through output

Rising and falling edge detector with 1 input and 1 output, plus general-purpose timer. This detects both the falling and rising edges of an input signal and outputs the ON signal for 5 ms.

92

Rising & falling edges detector + Off-delay timer

Rising & falling edge detector with 2 inputs and 1 output, plus Turning an input signal ON turns an output signal ON. Turning the input signal OFF starts the off-delay timer. When the period specified by the timer has elapsed, the output signal turns OFF.

Page 89: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

87

Block selection

Symbol Function block Description

93

Rising & falling edges detector + One-shot pulse output

Rising & falling edge detector with 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer.

100

Hold + Through output

Hold function of previous values of 2 inputs and 1 output, plus general-purpose timer. If the hold control signal is OFF, the function block outputs input signals; if it is ON, the function block retains the previous values of input signals.

101

Hold + On-delay timer Hold function of previous values of 2 inputs and 1 output with on-delay timer.

102

Hold + Off-delay timer Hold function of previous values of 2 inputs and 1 output with off-delay timer.

103

Hold + One-shot pulse output

Hold function of previous values of 2 inputs and 1 output with one-shot pulse output.

104

Hold + Retriggerable timer

Hold function of previous values of 2 inputs and 1 output, plus Turning an input signal ON issues a one-shot pulse whose length is specified by the timer. If an input signal is turned ON again during the preceding one-shot pulse length, however, the function block issues another one-shot pulse.

105

Hold + Pulse train output Hold function of previous values of 2 inputs and 1 output with pulse train output.

110

Increment counter

Increment counter with reset input. By the rising edge of an input signal, the function block increments the counter value by one. When the counter value reaches the target one, the output signal turns ON. Turning the reset signal ON resets the counter to zero.

120

Decrement counter

Decrement counter with reset input. By the rising edge of an input signal, the function block decrements the counter value by one. When the counter value reaches zero, the output signal turns ON. Turning the reset signal ON resets the counter to the initial value.

Page 90: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

88

Block selection

Symbol Function block Description

130

Timer with reset input

Timer output with reset input. If an input signal turns ON, the output signal turns ON and the timer starts. When the period specified by the timer has elapsed, the output signal turns OFF, regardless of the input signal state. Turning the reset signal ON resets the current timer value to zero and turns the output OFF.

2001

Adder with output

limiter

Addition function with two inputs (input1 and input2). This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides upper limit value and the 2nd one provides lower limit value.

2002

Subtracter with output limiter

Subtraction function with two inputs (input1 and input2). This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides upper limit value and the 2nd one provides lower limit value.

2003

Multiplier with output limiter

Multiplication function with two inputs (input1 and input2). This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides upper limit value and the 2nd one provides lower limit value.

2004

Divider with output limiter

Division function with two inputs (input1 and input2). Input1 is dividend and input2 is divisor. This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides upper limit value and the 2nd one provides lower limit value.

2005

Limiter

Upper and lower limit functions of single input (input1). The 1st function code provides upper limit value and the 2nd one provides lower limit value.

Page 91: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

89

Block selection

Symbol Function block Description

2006

Absolute value of inputs with output limiter

Absolute value function of single input (input1). (Negative input numbers become positive.) This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides upper limit value and the 2nd one provides lower limit value.

2007

Inverting adder with output limiter

Inverting addition function with single input (input1). This function adds input1 to the value specified with the 1st function code, inverts the result. And furthermore, the function adds the result to the value specified with the 2nd function code and outputs the result.

2008

Variable limiter Variable limit function of two inputs. Input1 provides the upper limit value and input2 provides the lower limit value.

2009

Linear function

Linear function of single input (input1). This function receives single input (input1), calculates pre-defined first-order polynomial, and outputs the result. The 1st and 2nd function codes provide the coefficients of the polynomial. The polynomial is represented by the following formula.

y = KA × x + KB The output is limited within the range between -9990 and 9990 by the internal limiter.

2051

Comparator 1

Comparison function with hysteresis. This function compares the differential value between input1 and input2 with the threshold value specified with the 1st function code. The 2nd function code provides hysteresis width. If input1 is (threshold value + hysteresis width) or bigger, this function outputs logical "1:True". On the other hand If the value is (threshold value - hysteresis width) or smaller, this function outputs logical "0:False".

2052

Comparator 2

Comparison function with hysteresis. This function compares the differential value between input1 and input2 with the threshold value specified with the 1st function code. The 2nd function code provides hysteresis width. If the differential value is bigger than (threshold value + hysteresis width), this function outputs logical "1:True".On the other hand If the value is smaller than (threshold value - hysteresis width), the function outputs logical "0:False".

Page 92: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

90

Block selection

Symbol Function block Description

2053

Comparator 3

Comparison function with hysteresis. This function compares the absolute differential value between input1 and input2 with the threshold value specified with the 1st function code. The 2nd function code provides hysteresis width. And this function works like as comparator 1

2054

Comparator 4

Comparison function with hysteresis. This function compares the absolute differential value between input1 and input2 with the threshold value specified with the 1st function code. The 2nd function code provides hysteresis width. And this function works like as comparator 2

2055

Comparator 5

Comparison function with hysteresis. Input1 is the input value of this function and input2 is not used. The 1st function code provides threshold value and the 2nd one provides hysteresis width. If input1 is (threshold value) or bigger, this function outputs logical "1:True".On the other hand If input1 is smaller than (threshold value - hysteresis width), this function outputs logical "0:False".

2056

Comparator 6

Comparison function with hysteresis. Input1 is the input value of this function and input2 is not used. The 1st function code provides threshold value and the 2nd one provides hysteresis width. If input1 is (threshold value) or smaller, this function outputs logical "1:True".On the other hand If input1 is bigger than (threshold value + hysteresis width), this function outputs logical "0:False".

Page 93: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

91

Block selection

Symbol Function block Description

2071

Window comparator 1

Comparison function with limits. The output is determines when the input is within a preselected range specified with two function codes. Input1 is the input value of this function and input2 is not used. The 1st function code provides upper threshold value and the 2nd one provides lower threshold value. If input1 is within the range (defined with two function codes), this function outputs logical "1:True".On the other hand If input1 is out of range, this function outputs logical "0:False".

2072

Window comparator 2

Comparison function with limit. This function has the inverting function block of " Window comparator 1".

2101

High selector with output limiter

High selector function. This function receives two inputs (input1 and input2), selects the higher one automatically, and outputs it. This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides the upper limit value and the 2nd one provides the lower one.

2102

Low selector with output limiter

Low selector function. This function receives two inputs (input1 and input2), selects the lower one automatically, and outputs it. This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides the upper limit value and the 2nd one provides the lower one.

2103

Average of inputs with output limiter

Average function. This function receives two inputs (input1 and input2), averages them, and outputs the result. This function has output limiters (upper/lower) specified with two function codes. The 1st function code provides the upper limit value and the 2nd one provides the lower one.

4001

Hold with output limiter

Function to hold analog 1 input based on digital 1 input.

Page 94: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

92

Block selection

Symbol Function block Description

4002

Inverting adder with enable

Function to reverse analog 1 input based on digital 1 input.

4003

Selector 1 Function to select analog 1 input and setting value based on digital 1 input.

4004

Selector 2 Function to select setting value 1/2 based on digital 1 input.

4005

LPF(Low pass filter) with enable

Value of an analog 1 input is filtered through LPF (time constant U04) when the digital 1 input is "1". When the digital 1 input is "0", the analog 1 input is directly output. (LPF maintains the previous output value. Therefore, when the digital 1 input changes from 0 to 1, the output will be the value with the previous output value added as the initial value of LPF.) (No upper/lower limiter)

4006

Rate limiter with enable

Value of an analog input is limited with change rate specified in functions 1 and 2 when the digital 1 input is "1". When the digital 1 input is "0", the analog 1 input is directly output. When setting the initial value, carry out an operation with the initial value for input 1 and 0 for input 2. Then, reflect the result as the initial value (= previous output value) with 1 applied to input 2. During the initialization or when the CLC terminal is ON, the previous output value is cleared to 0.

5000

Selector 3 Function to select analog 2 input based on

"SO01" to "SO200".

5100

Selector 4 Function to select analog 1 input and "SO01"

to "SO200" based on digital 1 input.

Page 95: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

93

Block selection

Symbol Function block Description

6001

Reading from function code

Function to read the content of arbitrary function code. Use the 1st function code (such as U04) to specify a function code category, and the 2nd one (such as U05) to specify the last two digits of the function code number. For the function code settings, refer to maintenance manual. Both input1 and input2 are not used. Data formats that can be read correctly are as follows (the values are restricted between -9990 and 9990 and, for [29], 20000 is indicated as 100%): [1], [2], [3], [4], [5], [6], [7], [8], [9], [10], [12], [22], [24], [29], [35], [37], [45], [61], [67], [68], [74], [92], and [93]

Data formats other than the above cannot beread correctly. Do not use any other format.

6002

Writing to function code

This function writes the value of input 1 to a function code (U171 to U175) on the volatile memory (RAM) when the input 2 becomes “1:True”. When the input 2 becomes “0:False”, this function stops to write to the function code (U171 to U175) and maintains the previous value. The value of input 1 is stored to the non-volatile memory (EEPROM) when the inverter detects undervoltage. Because the access arbitration from some steps at a time is not possible, only one step is allowed with accessing to the same function code in the customizable function. If the access to the target function code from some steps at a time is executed, the alarm is displayed.

6003

Temporary change of function code

This function reflects the value of the specified function code on the volatile memory (RAM) when the input 2 becomes "0:False". On the other hand when the input 2 does not become "0:False", this function reflects the value of input 1 in the place of the function code.

・For the timer operation, if the processing time is greater than the set value, it operates in a

time corresponding to the processing time by ignoring the setting.

Page 96: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

94

2.3.3.8. Specifications of Customizable function

Item Modes

Terminal command Digital 2 input Analog 2 input Analog 1 input Digital 1 input

Operation block Logical operation, counter, etc.: 13 types Timer: 5 types

Numerical operation, comparator, limiter, etc.: 25 types

Selector, hold, etc.: 12 types

Output signal Digital 1 output Analog 1 output/ Digital 1 output

Analog 1 output

Maximum number of steps 200 steps

Maximum number of output signals from customizable function

10 outputs

Customizable function processing time

2 ms (max. 10 steps), 5 ms (max. 50 steps), 10 ms (max. 100 steps), 20ms (max. 200 steps) Can be selected with the function codes.

Note Customizable function or their timers are available to be cancelled with external command "CLC" or "CLTC".

Page 97: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

95

2.3.4. Tace

The trace feature, there are two types.

①Real-time trace :Suitable for monitoring for long hours

②Historical trace :Suitable for monitoring short-period samples

Item Rial-time Historical

Sampling time 20ms ~ 200m 1ms ~ 200ms

Sampling number

60000 point/Ch (The number that can be displayed continuously)

500 point/Ch

Number of display data

Analog:4

Digital:8

Analog:4

Digital:8

If you select four analog Channel, it will not be able to select the digital Channel.

2.3.4.1. Real-time trace

Select from the toolbar of the main window, When clicked [Real-time trace], opens

[Real-time trace] dialog. Also when you click on the Menu | Trace | Real-time trace opens

[Real-time trace] dialog.

The following shows the Real-time trace window.

・Real-time trace works even without trigger setting.

Sub window

・Mitor

・ Graph position

adjustment

Cursor position

Trace operation status display

Trace start/stop (not selectable)

Cursor movement bar

nt bar

Detail setting of each channel

Read waveform data

Trace type display

Save trace data

Waveform monitor hardcopy

Waveform monitor

Cursor A

Cursor B monitor

Waveform screen scroll bar

Page 98: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

96

2.3.4.2. Historical trace

Select from the toolbar of the main window, When clicked [Historical trace], opens

[Historical trace] dialog. Also when you click on the Menu | Trace | Historical trace opens

[Historical trace] dialog.

The following shows the Historical trace window.

・Historical traces, please be sure to set the trigger.

Refer to trigger setting of analog Channel / digital Channel of "2.3.4.8

Waveform Detail Settings”.

Sub window

・Mitor

・ Graph position

adjustment

Cursor position

Save trace data

Waveform monitor hardcopy

Trace operation status display

Trace start/stop (not selectable)

Cursor movement bar

Waveform monitor

Cursor A

Cursor B

Waveform screen scroll bar

Trace type display

Detail setting of each channel

Page 99: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

97

2.3.4.3. Monitor Start/Stop

To start monitoring of Real-time trace/Historical trace, click the [START/STOP] button in the

middle of the upper side of the trace screen.

To stop monitoring, click the [START/STOP] button again.

When start the monitor, “display of trace type” flashes in the middle of the upper side of the

trace screen.

Also, “display of trace operating state” will change as follows.

⇒ ⇒ ⇒

Display of trace

operating state Description

Stop Stop the trace operations.

Pre Trigger

In trace operations, it is in the state that have taken up the data before

the trigger point.

Caution) When in this state, it does not trigger detection.

Wait Trigger In trace operations, it is in the state waiting for the trigger detection.

Running In trace operation, to detect the trigger, and then displays the data on

the screen.

Page 100: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

98

2.3.4.4. Save Trace Data

To save each trace data, click [Save] button in the upper center in the trace window or select

[File] -> [Save As…].

When selecting [Save] for the data for the first time, the following dialog will open in the same

manner as when selecting [Save As …]. Select [Save to…] and [File Type], enter the file name

under which the file is saved in [File Name] and then click [Save] to determine the entry.

・Realtime trace data :「*.RT1」

・Historical trace data :「*.HT1」

・Comma delimiter :「*.CSV」

・trace data (Graph image) :「*.JPG」

2.3.4.5. Copy Trace Data Screen

To copy each trace data screen, click [Copy] button in the upper center in the trance screen.

Then, the screen is copied in the clip board. You can paste it onto the target document.

Page 101: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

99

2.3.4.6. Print Trace Data

To print the trace data, set the trace screen in the active state and select [File] -> [Print]. The

trace data is printed as shown below.

Page 102: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

100

2.3.4.7. Sub Window

[ 1 ] Cursor

Each box in the cursor sub window shows the channel setting values or status at each cursor

position.

Select cursor display

Vertical: Two cursors (Cursor A, Cursor B, Cursors A and B)

Horizontal: Two cursors (Cursor A, Cursor B, Cursors A and B)

No display

Cursor value monitor

Analog channel: 4 channels

Digital channel: 8 channels

(You can display the hidden portions using the cursor value monitor vertical slide bar.)

Use the scroll bar to move to the waveform screen to be analyzed and click the point to be

observed in the graph. The cursor will move to that position. The cursor movement position is

the sampling point (time point) closest to the clicked point. The trace data of all channels on the

cursor appears in the measurement monitor.

Alternatively, you can move the cursor using the cursor movement bar or by dragging the

mouse.

The cursor keys on the keyboard are also available.

However, while tracing, neither waveform screen nor cursor can be moved.

Cursor values at analog Channel

Settings on cursors

Cursor values at digital Channel

Cursor A Cursor B Cursor value monitor vertical slide bar

Page 103: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

101

[ 2 ] Adjust graph position

Each box in the cursor sub window shows the channel setting values or status at each cursor

position.

You can use the boxes to adjust the graph position at each channel.

Select Channel

Select the channel at which the graph position is adjusted. Display

Display only the channels with checked mark. Hide the channels without checked mark. Y axis display position

Set the Y axis display position of the selected channel. The upper end comes to 0 point (50 points each at grid). X axis display position

Set the X axis display position of the selected

channel. The leftmost end comes to 0 point (200

points each at grid).

Amplitude

Set the amplitude of the selected channel by magnification (in increments of 0.25).

Change the magnification using 0 point for reference.

As changing the amplitude input value, Scale/DIV value changes in unison and the graph

display also changes according to the Scale/DIV value.

Scale

Set the scale of the selected channel.

Enter the numeric value per DIV. This setting covers the analog setting channels only.

Graph position reset

Reset the display position and amplitude setting of the selected channel to the initial values.

・Y axis display position: Ch1 = 50 and the value increments by +50 for the subsequent

channels.

・X axis display position: Each Channel = 0

・Amplitude: 1.00

Page 104: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

102

Optimize Y axis graph

Arrange the Y axis display position and scale of the displayed channels without overlapping by

channel. Reset the amplitude setting to the initial value.

・Y axis display position: Ch1=100 and the value increments by +100 for the subsequent

channels.

・Scale: Set the scale value so that the maximum value can be within two grids.

(Minimum unit: 50)

Detect waveform peak

Move Cursor A to the maximum value of the selected channel automatically. If there are two or

more peaks, the cursor moves to the earliest one.

Display range in one DIV

Set the time to be displayed in one waveform monitor screen.

Historical trace:

(100ms,200ms,500ms,1s,2s,5s,10s,20s,30s,1min,5min,10min)

Real-time trace:

(100ms,200ms,500ms,1s,2s,5s,10s,20s,30s,1min,5min,10min,20min,30min,60min)

Color setting

The color setting data is held. When obtaining the waveform, you can change the color setting.

Channel line

Line color and line type of the trace data of the selected channel.

Cursor line A

Select the line color, line type and line thickness of Cursor line A.

Color line B

Select the line color, line type and line thickness of Cursor line B.

Trigger line

Select the line color, line type and line thickness of the trigger line.

Grid line

Select the line color, line type and line thickness of the grid line.

Graph background color setting

Select the waveform monitor background color.

Page 105: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

103

The settings of the trace line of each CHANNEL are as below:

・Color

・Type of line ・Thickness

Page 106: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

104

2.3.4.8. Waveform Detail Settings

[ 1 ] Channel configuration

You can set the configuration of analog channels and digital channels to be traced. See [2] to

[5] for detail settings of each channel.

・Target inverter

Select No. of the inverter registered in Connection Setting.

[ 2 ] Ch1 to Ch4 (analog setting)

You can set the analog channels.

Page 107: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

105

・Filter setting

You can do settings on filters of each channel.

Not used

Select this when no file is used.

Manual filter

Low path filter with filter time constant freely set.

Set the filter time constant using numeric values.

The setting range is from 1 [ms] to 100 [ms].

・Filter time constants, please set the more than twice the sampling time.

・Trigger

Settings for the trigger of each Channel are as follows.

Trigger setting

Select a channel to set the trigger.

Analog channels can be set only one trigger.

Trigger level

Set the amount of data to handle the monitor item selected in

each channel.

Trigger edge

Set the trigger of rising (↑) edge or falling, (↓) edge.

Page 108: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

106

・Signal selection

The information items of the inverters that can be monitored are as shown below.

Analog channel signal selection items (Real-time trace/Historical trace).

No Item

0 Reference speed (Pew-ramp)

1 Reference speed (Final)

2 Primary frequency

3 Output current

4 Output voltage

5 Detected speed

6 Reference torque

7 Reference torque current (Final)

8 Torque current

9 Reference torque bias (Final)

10 Torque calculation value

11 Input power

12 DC link circuit voltage

13 Inverter internal air temperature

14 Heat sink temperature

15 [12] input voltage

16 [C1] input current

17 [V2] input voltage

18 Electric angle

19 Mechanical angle

20 Detected magnetic pole position

21 Detected speed (p.u.)

22 Output current (Instantaneous value)

23 Torque current (Instantaneous value)

*The trace for customizable logic the number of items increases.

Page 109: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

107

[ 3 ] Ch1 to Ch8 (digital setting)

You can set the digital channels.

・Trigger

Settings for the trigger of each Channel are as follows.

Trigger setting

Set the Low level, Hi level, the rising (↑) edge and falling (↓) edge.

Digital channels can make more than one trigger setting.

It can be selected in each trigger "OR" or "AND" condition.

*Please refer to the "trigger detection conditions" of "[5] Other

Settings".

Page 110: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

108

・Signal selection

The information items of the inverters that can be monitored are as shown below.

Signal selection block “Input terminal (X1 – X8, EN, FWD, REV)” items

No Item

0 X1

1 X2

2 X3

3 X4

4 X5

5 X6

6 X7

7 X8

8 EN

9 FWD

10 REV

Signal selection block “Output terminal (Y1 - Y5, 30A/B/C)” items

No Item

0 Y1

1 Y2

2 Y3

3 Y4

4 Y5

5 30A/B/C

Page 111: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

109

[ 4 ] Chsetting check (analog/digital)

The data set in each channel is listed. To reflect the setting, click OK button. To cancel the

setting, click Cancel button.

Page 112: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

110

[ 5 ] Other settings (including sampling time setting)

Do the detail settings for the waveform monitor.

・Sampling time setting

Sampling time setting is as shown below.

Sampling time setting Real-time Historical

1ms × ○

2ms × ○

5ms × ○

10ms × ○

20ms ○ ○

30ms ○ ○

50ms ○ ○

100ms ○ ○

200ms ○ ○

Page 113: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

111

・Pre-trigger position

Set the number of sampling points of data prior to the trigger position.

・Trigger detection conditions

Specify the trigger detection conditions--"OR" or "AND."

Analog:1 channel only

Digital:1 to 8 channel

・Trace start timi setting

Set the schedule to start the trace.

・Tace autosave

Set if you want to save the trace data automatically.

・Save size (Valid only Real-trace)

Split the file if save the real-time trace data automatically.

Set the total file size of the split files.

Page 114: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

112

2.3.4.9. Combination of a customizable logic functions

Trace monitor is available to select after downloaded the created function setting to the inverter

or if the functions of the inverter are fully consistent with the functions of the software under test.

In customize logic editor screen, then select "Trace monitor select" from the context menu with

right-click.

Save the information of the selected symbol.

Go to the real-time trace, and then import the saved symbol information.

Page 115: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

113

Next click the "Advanced" button, set number of Channel that to be used, select signal of

Channel (Refer to "2.3.4.8Waveform Detail Settings").

All signals from the customizable logic (digital or analog) can be selected in the "analog

Channel" tab.

In the case of monitoring the digital signal, set "scale" of the "graph position adjustment" tab to

"2".

Page 116: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

114

2.4. Setup

2.4.1. Communication Setup

Refer to "1.4.4Communication Settings".

2.4.2. Language

Sets the language of the loader. Select the Setup| Language | Japanese or English, then exit

the loader.

You can select "English" and "Japanese" language.

After you have selected a language, exit the loader and restart the loader.

Switches to the selected language when restart the loader.

* If you do not exit the loader and restart the loader, language is not changed.

Page 117: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

115

2.5. View

Selecting View | Toolbar | Main shows or hides the toolbar.

Selecting View | Status Bar shows or hides the status bar.

2.6. Toolbar

The toolbar, which is usually located at the top of the Loader window, contains program icons

and allows you to access the desired function (program) with a single click.

Toolbar

Status bar

2.7. Status bar

The status bar, which is usually located at the bottom of the Loader window (as shown above),

shows the running status of the currently selected inverter and the program execution status.

Page 118: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

116

2.8. Window

Specify how to display the Loader windows on the Loader top window. This facility becomes

active only if any window is opened on the top window.

2.8.1. Cascade windows

Selecting Window | Cascade arrange multiple windows, overlapping each other. You can call

an inactive window up by clicking its title bar.

Page 119: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter2 Description of Functions

117

2.8.2. Tile windows

Selecting Window | Tile tiles multiple windows so that all windows are seen together.

2.8.3. Tile windows vertically

Selecting Window | Tile vertically tiles multiple windows vertically.

Page 120: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

118

2.8.4. Arrenge icons

Selecting Window | Arrange Icons arranges icons of the active windows or programs at the

bottom of the Loader top window.

2.9. Help

2.9.1. Version Information

Version Information shows the Loader version, copyright.

Page 121: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter3 Frequently asked questions (FAQ)

119

Chapter3 Frequently asked questions (FAQ)

3.1. Cannot communicate with inverter (Failed to get

inverter information)

3.1.1. Message Manager not installed correctly

Message Manager is software that manages communication between the PC and inverter.

If Message Manager has not been installed correctly, your PC cannot communicate with the

inverter. The installation state can be checked in the task bar of Windows OS (see the Message

Manager icon sample given below). If no Message Manager icon is displayed in the task bar,

Message Manager has not been installed correctly.

Delete the folder (including its contents) named Fuji Electric Shared in the file path as shown

below, and then Uninstall Loader.

C:¥Program Files¥Common Files¥Fuji Electric Shared

(In the file path shown above, "C" represents the drive letter of the partition or hard disk where

Windows is installed. If Windows is installed on a different drive in your system, replace "C" with

the letter corresponding to that drive.)

・Message Manager icon sample

Click here to show the hidden icon.

There are times when an icon is displayed here.

Page 122: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

120

3.1.2. USBriver not installed correctly

Refer to "1.3.1.3Installing USB driver".

3.1.3. USB driver has been installed correctly, Loader cannot

communicate

Although the USB driver has been installed correctly, Loader cannot communicate with the

inverter. This problem is considered to be caused by installing the USB driver when Message

Manager is running.

In this case, Message Manager is no longer able to recognize the USB driver, so it is necessary

to quit both Loader and Message Manager and then start Loader again.

・Quitting Message Manager

Click this to display the hidden icons as shown below.

Right-click this icon to display Exit MessageManager, then click it. The confirmation window

appears. Click Yes to quit Message Manager.

There are times when an icon is displayed here.

Page 123: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter3 Frequently asked questions (FAQ)

121

3.1.4. USB communication impossible after the PC has gone

standby or to sleep

If Windows 7 or Windows Vista goes standby or to sleep, Loader cannot recognize the USB

driver so that it cannot communication with the inverter. Follow the instructions given below.

[ 1 ] Windows 7

Turn the PC power OFF and ON, then restart Loader.

Note: Unplugging and plugging the USB connector cannot enable the OS to recognize the USB

driver again.

Please cancel the standby (sleep) state.

Open the Control Panel | System and Security | Power Options | Edit plan settings,

please set the “Put the computer to sleep” to "No".

[ 2 ] Windows Vista

Unplug and plug the USB connector, then restart Loader.

Note: Unplugging and plugging the USB connector enables the OS to recognize the USB driver

again.

Page 124: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Chapter4 Specifications

122

Chapter4 Specifications

Item Specifications Remarks

Name of software FRENIC Loader

Supported inverter FRENIC-Lift LM2 series

No. of supported

inverters

For USB connection: Only one inverter

For RS-485 connection: Up to 31 inverters

Recommended cable

RS-485 : Shielded twisted pair cable for

long distance transmission

USB : TP-E1U (option)

USB cable (mini B connecter)

RS-485 :

Refer to “1.2.2Configuring

an RS-485 communications

network"

USB :

Refer to “1.2.3Configuring

USB network"

Op

era

ting

enviro

nm

en

t

OS Microsoft Windows Vista

Microsoft Windows 7

Memory 1GB or more RAM 2GB or more is

recommended

Hard disk 160MB or more free space

COM port RS-232C or USB

Conversion to RS-485

communications required to

connect inverters

Monitor resolution 800 × 600 or higher XGA (1024 × 768)/32-bit

color is recommended

Tra

nsm

issio

n r

eq

uir

em

en

ts

COM port COM1 to COM255 PC COM ports assigned to

Loader

Transmission rates

USB connection : Fixed at 12 Mbps

RS-485 connection :

38400, 19200, 9600, 4800 and 2400 bps

38400bps or more is

recommended.

Character length 8 bits Prefixed

Stop bit length 1 bit Prefixed

Parity Even Prefixed

No. of retries None or 1 to 3 to 10

No. of retry times before

detecting communications

error

Timeout setting 100ms, 300ms, 500ms, 1.0s to 1.9s, 2.0

to 9.0s, 10.0 to 60.0s

Page 125: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control
Page 126: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

MEMO

Page 127: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Inverter Support Software

FRENIC Loader

Instruction Manual

First Edition November 2015

Fuji Electric Co., Ltd.

The purpose of this manual is to provide an operation guide to FRENIC Loader for the FRENIC series of

inverters. Please feel free to send your comments regarding any errors or omissions you may have found,

or any suggestions you may have for generally improving the manual.

In no event will Fuji Electric Co., Ltd. be liable for any direct or indirect damage resulting from the

application of the information in this manual.

Page 128: Inverter Support Software FRENIC Loader - Fuji Electric Europe...Inverter Support Software FRENIC Loader Instruction Manual Thank you for purchasing our high-performance, vector control

Fuji Electric Co., Ltd.

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan

URL http://www.fujielectric.co.jp/

2015-11