1. Amendment Number:
2. Issued By:
3. Amendment of Solicitation (IFB) No. Dated Posted: 09/30/2016
Thank You!
David Cortez, Procurement Specialist
Vendor Signature
Company
Date
Submit this document to [email protected]; or fax (713) 622-4762 prior to the hour and date specified for receipt of
bids/proposals
Amendment - 04
5. Description of Amendment
David Cortez
APV-16-03
Except as provided herein, all terms and conditions of the solicitation remain unchanged and in full force and effect.
INVITATION FOR BIDS (IFB) NO. : APV-16-03 , PITCHED ROOFS REPLACEMENT PROJECT
SOLICITATION AMENDMENT
Tuesday, November 1, 2016
4. The above-numbered solicitation is amended as set forth below. Bidders/offerors must acknowledge receipt of this
amendment prior to the hour and date specified for receipt of bids/proposals, by signing this form below or by completing the
acknowledgement on the form titled “Solicitation, Bid/Proposal and Award.”
Responses to bidders/offerors questions for Project Number - APV-16-03, please review the following documents provided
from AT3 & RDC Architect and Allied Orion Group.
Allied Orion Group - Solicitation Amendment
TASK ORDER 02 ALLEN PARKWAY VILLAGE OCTOBER 2016
AT3+RDC Architects 4141 SW Freeway, Suite 150 Houston, Texas 77027 713.521.2808 713.521.2804 Fax
October 31, 2016
Allen Parkway Village – Pitched Roof Project 1600 Allen Parkway Houston, Texas 77019
ADDENDUM NO. ONE (Green)
Please consider the following revisions and clarifications in the bidding for the Allen Parkway Village – Pitched Roof Project (42 Buildings). All information, project manual sheets and/or drawings under this addendum shall supersede and/or replace the previously issued bid documents or information.
General Revisions and Clarifications from Contractor Pre-Bid Meeting, RFI’s, and Questions submitted for response.
PROJECT INFORMATION
1) Reference attachments I-1, I-2, I-3 and I-4 for revised information. PROJECT MANUAL
1) Revised Specification Section 07 01 50 PREPARATION FOR RE-FOOFING ARCHITECTURAL/ROOFING ITEMS:
1) Will a site map of the complex A-1.0 of the plans be provided with corresponding matching building number that are noted on pages A-2.00 through A-2.18 of the plans?
No, bid documents shall remain issued as is to correspond with approved permit documents. Provided bid documents made be marked and noted as required by General Contractor and/or their Sub-Contractor.
2) Does the new drip edge have to be painted metal or galvanized metal?
Provide paint grip galvanized metal drip edge.
TASK ORDER 02 ALLEN PARKWAY VILLAGE OCTOBER 2016
3) How are existing damaged gutters and downspouts to handle? Replace with
new or re-install damaged?
Replace all existing gutters and downspouts with new sheet metal gutters and
downspouts to match the existing sizes, lengths and profiles. Minimum 26 gauge
pre-finished sheet metal color to be selected by Architect. Provide roof attached
strap applied gutter and downspout anchors. Typical at all forty-two (42) buildings.
4) The existing metal turtle vents, are these to be reused and painted or replaced
with new? The existing vents are of better quality than typical new metal turtle
vents.
Salvage and store all existing metal turtle vents and repair existing deteriorated
and/or damaged roof decking as required to re-install all existing metal turtle vents.
Clean, prepare and provide new paint finish for all existing metal turtle vents. Paint
color to be selected by Architect.
5) Specification Section 07 31 13; Part 3.4 Ice and Water Shield. Is Ice and Water
shield required only in the valleys? Manufactures only require at the eaves in
ice prone areas of the country.
Yes, provide Ice and Water shield at both locations. All roof valleys and eaves.
6) The form that we submit the bid price on is the sheet entitled “project cost
estimate” with header as Division Code, Davison Name, Unit Cost, Labor Cost
and Total Cost?
Provide General Contractor’s standard tabulation form to itemize and quantitate
proposed Unit Cost for material and Labor for Division Name, Unit Cost, LABOR
Cost and Total Cost to comply with “Drawing Sheet A2.0, Items;1A, 1B and 1C as
noted.
7) Also, Clarification or definition of Davion Code etc.….we are trying to be sure to
be provide an understandable base bid as well as providing unit break down for
rotten decking etc.….So we are thinking that perhaps the division Code would
be one line item for roofing and another for 5” gutter cost for example and
another for ½” plywood decking cost?
Proceed as stated in response Number 6 above.
8) Permit FEES.
Permit FEES will be posted under Addendum No. 2 to be issued no later than
11/3/2016 before close of business.
TASK ORDER 02 ALLEN PARKWAY VILLAGE OCTOBER 2016
DRAWINGS:
1) Reference attached re-issued Drawing Sheet A 0.01
2) Reference attached issued Drawing Sheet R2.01
3) Reference attached Sketch SK-1 ridge vent detail to replace detail 4/R2.01 keyed on
Drawing Sheet R2.01
MISCELLANEOUS ITEMS: NONE
End of Addendum No. 1
AT3+RDC Architects
Calvin W. Deese, Sr., CSI
Senior Project Manager
I: PROJECT INFORMATION
HHA – APV 02 I-1
1.0 PROJECT NAME/ADDRESS
Allen Parkway Village, Pitched Roofing Replacement Project
1600 Allen Parkway Houston, Texas 77019
2.0 OWNER
Houston Housing Authority 2640 Fountain View, Suite 400 Houston, Texas 77057
Real Estate Investment and Development Department Contact: Chris Bergmann, Vice President - REID Phone: 713-260-0800 E-mail: [email protected]
Contact: Lawrence Bowie, Manager, Capital Funds Projects Phone: 713-260-0683 E-mail: [email protected]
3.0 PROJECT MANAGER Houston Housing Authority’s Program Administrator/Project Manager.
Project Manager: THE ALLIED ORION GROUP 2051 Greenhouse Road, Suite 300
Houston, Texas 77084
Contact: Cynthia Fowler, Sr. Regional Supervisor Phone: 713-622 – 5844 Ext 1153 E-mail: [email protected]
Contact: Chris Varnell, Project Manager Phone: 713-622 – 4949 Ext 1117 E-mail: [email protected]
ARCHITECT/ENGINEER/ROOF CONSULTANT Drawings and Specifications have been prepared by the Architect/Engineer (A/E), AT/3+RDC Architects, at 4141 SW Freeway, Suite 150, tel. 713-521-2808, fax 713-521-2804. Documents include Drawings and Specifications. Information and inquiries about these documents should be directed to the A/E through the Project Manager.
AT/3+RDC Architects 4141 SW Freeway, Suite 150 Houston, Texas 77004
Contact: Stennis Lenoir, AIA, LEED AP OFF: 713-521-2808 FAX: 713-521-2804 [email protected]
I: PROJECT INFORMATION
HHA – APV 02 I-2
Contact: Calvin Deese, PM
OFF: 713-868-0088 FAX: 713-468-2613 [email protected]
ARMKO Industries, INC. 3411 Cobblestone Creek Way Houston, Texas 77064
Contact: Jim Barton OFF: 281-398-1300 FAX: 281-398-1328 [email protected]
5.0 SCOPE OF WORK
WORK COVERED BY THE CONTRACT DOCUMENTS
5.1.1 Project Identification: Allen Parkway Village- Pitched Roofing Replacement Project
5.1.1 Project Location: Allen Parkway Village, 1600 Allen Parkway
Pitched Roofing Scope of Work.
The Allen Parkway Village Pitched Roofing Project is a Capital Improvement project that will be implemented and Managed by the Houston Housing Authority. The Construction Documents and Specifications are produced by AT3+RDC Architects. The Documents will be available for pickup/review at the Houston Housing Authority on _____________________.
There are a total of forty two (42) buildings involved in this project.
Two buildings (1 Story) Laundry Room Facilities,
Forty Buildings (2 Story and 3 Story) buildings dispersed throughout the APV Property Site.
This project involves the removal of the existing composition shingle roof and base protection layers down to the Ply Wood Roof deck. Replacement roof shall be a new 25 year composition shingle roof as specified in the Construction Documents. Existing Metal Gutters and Downspouts shall be removed and replaced with new Gutters and Downspouts to match existing/as specified, after installation of the new composition shingle roof system. The existing ply wood roof decking shall be inspected and if any water damaged decking is encountered, it shall be replaced. An established Allowance for decking replacement will be
I: PROJECT INFORMATION
HHA – APV 02 I-3
specified in the Project Manual. All existing wood Fascia and Trim shall be inspected and if any water damaged Fascia/Trim is encountered, it shall be replaced. Established Allowance for Fascia/Trim replacement will be specified in the Project Manual. All new Fascia/Trim shall be painted to match the removed Fascia/Trim boards. All New materials color selections at all locations shall be coordinated with Architect.
The Forty Two buildings in the Historic Oaks Section are occupied facilities and will remain so throughout this project. The selected Roofing Contractor will participate in the development and Coordination of the work schedules for the Roofing work with HHA, Allied-Orion, and the A/E Team will be required
PRE-PROPOSAL MEETING AND SITE TOUR:
A pre-proposal conference and site tour will be held on, October, 18, 2016 starting at 11:00 A. M. in the Seniors Center, located at 1600 Allen Parkway, Houston Texas. All general contractors and sub-contractors are encouraged to attend this meeting.
6.0 RECEIPT OF PROPOSALS: Sealed Proposals for the Allen Parkway Village Flat
Roofing Replacement Project are due on November 07, 2016 at 12:00 P.M. CTS.
7.0 OWNER PROVIDED DOCUMENTS
Drawing and Specification List **(100% CONSTRUCTION DOCUMENTS ISSUED DRAWINGS) **
COVER SHEET
A 0.1 DESIGN TEAM/INDEX OF DRAWINGS A 0.2 EXISTING CONDITIONS PHOTOS A 0.3 EXISTING CONDITIONS PHOTOS A 0.4 EXISTING CONDITIONS PHOTOS
ARCHITECTURAL DRAWINGS A 1.0 COMPOSITE SITE PLAN A 2.0 ROOF PLAN BUILDING TYPE G-I, II A 2.1 ROOF PLAN BUILDING TYPE G-III A 2.2 ROOF PLAN BUILDING TYPE R-I, II A 2.3 ROOF PLAN BUILDING TYPE R-IIt, III A 2.4 ROOF PLAN BUILDING TYPE R-IV A 2.5 ROOF PLAN BUILDING TYPE R-IVt A 2.6 ROOF PLAN BUILDING TYPE R-V A 2.7 ROOF PLAN BUILDING TYPE R-VI A 2.8 ROOF PLAN BUILDING TYPE R-VII A 2.9 ROOF PLAN BUILDING TYPE R-VIII A 2.10 ROOF PLAN BUILDING TYPE R-IX
I: PROJECT INFORMATION
HHA – APV 02 I-4
A 2.11 ROOF PLAN BUILDING TYPE R-X A 2.12 ROOF PLAN BUILDING TYPE R-XI A 2.13 ROOF PLAN BUILDING TYPE R-XII A 2.14 ROOF PLAN BUILDING TYPE R-XIIt A 2.15 ROOF PLAN BUILDING TYPE R-XIII t1 A 2.16 ROOF PLAN BUILDING TYPE R-XIII t2 A 2.17 ROOF PLAN BUILDING TYPE R-XIV A 2.18 ROOF PLAN BUILDING TYPE R-XIV R 2.01 ROOFING SECTION DETAILS
End of Section
AT/3+RDC Architects HHA_APV 02 100% CD Submittal
HHA / APV-02 07 01 50
SECTION 07 01 50 PREPARATION FOR RE-ROOFING
1.1 SUMMARY
A. Roof tear-off.
B. Partial roof tear-off.
C. Roof re-cover preparation.
D. Removal of base flashings.
E. Protection of existing roofing system that is not to be re-roofed.
1.2 PROJECT CONDITIONS
A. Owner will occupy portions of building immediately below reroofing area. Conduct reroofing so owners operations are nor disrupted.
B. Construction Loads on Roof: Concentrated Loads not to exceed. _______ Uniformly Distributed Loads not to exceed. _______ C. Roof Moisture Survey: NONE.
D. Test Cores: NONE.
E. Asbestos: Contractor to (Verify w/owner provided reports where necessary)
1.3 MATERIALS
A. Temporary Roofing: [Sheathing paper] or [base underlayment sheet] .
B. Recover Boards: [NONE]
C. Plywood: DOC PS1, Grade CD Exposure 1.
D. OSB: DOC PS2, Exposure 1
1.4 EXECUTION
A. Roof Tear-Off: Existing roofing shingles, underlayment and fasteners to be removed.
B. Remove all existing Gutters and Downspouts such as not to damage existing fascia boards, walls and trim boards. Prepare surfaces for installation of new gutters and downspouts as scheduled in the drawings and the specifications.
AT/3+RDC Architects HHA_APV 02 100% CD Submittal
HHA / APV-02 07 01 50
C. Inspect existing Ply Wood Decking for water damaged areas and structural integrity. Coordinate with Project Manager if any Ply Wood sheet replacement is needed.
D. Fastener Pull-Out Testing: By Contractor-engaged testing agency as required.
E. Protect building to be reroofed, adjacent buildings, walkways, site improvements, exterior plantings, and landscaping from damage or soiling from reroofing operations.
F. Conditions existing at time of inspection for bidding are maintained by Owner as far as practical. Contractor is responsible for conclusions derived from existing conditions.
G. Weather Limitations: Proceed with reroofing preparation only when existing and forecasted weather conditions permit Work to proceed without water entering existing roofing system or building. Remove only as much roofing in one day as can be made watertight in the same day.
H. Maintain Drainage: Ensure each roof area has suitable drainage at the end of each day of work.
1.5 DISPOSAL
A. Collect demolished materials and place in dumpster/containers. Promptly dispose of demolished materials. Do not allow demolished materials to accumulate on-site.
B. Storage or sale of demolished items or materials on-site is not permitted.
C. Transport and legally dispose of demolished materials off Owner’s property.
END OF SECTION 07 01 50
OLD METAL COUNTER-FLASHING RE-USED
IF SERVICABLE AS SPEC.
NONCORRODING METAL COUNTER-FLASHING
TO EXTEND DOWN OVER BASE FLASHING AS SPEC.
ROOFING CEMENT AS SPEC.
STEP FLASHING POSITIONED OVER
SHINGLE SO THAT NEXT COURSE OF
SHINGLES COVERS IT COMPLETELY AS SPEC.
1. INSTALL LEAK BARRIER AT LEAST 16" ON ALL SIDES.
2. ALL METAL FLASHING TO BE A MINIMUM .024" (24 GAUGE) ALUMINUM, 16 OZ. COPPER OR 1.5 LB LEAD.
3. EXTEND FLASHING A MINIMUM OF 4" BEYOND THE CHIMNEY ON THE FRONT AND SIDES AND A MINIMUM OF 16" BEHIND THE
CHIMNEY.
4. A CRICKET IS REQUIRED BEHIND ALL CHIMNEYS WIDER THAN 24 INCHES OR LOCATED ON ROOFS STEEPER THAN 6 INCHES PER
FOOT.
WEATHERWATCH OR STORMGUARD LEAK BARRIER
AROUND ENTIRE CHIMNEY AS SPEC.
ALTERNATE:
OPTION:
1. NOT ALL SHINGLES ARE SHOWN FOR CLARITY.
2. UNDERLAYMENT TYPE AND NECESSITY MAY VARY DEPENDING ON CLIMATIC CONDITIONS.
L-TYPE EDGE METAL
FLASHING AS SPEC.
EDGE METAL
FLASHING AS
SPEC.
ICE DAM PROTECTION
MEMBRANE AS SPEC.
ASPHALT SHINGLES
AS SPEC.
UNDERLAYMENT AS
SPEC.
1. UNDERLAYMENT CAN BE INSTALLED ON TOP OF OR UNDER THE EAVE EDGE METAL FLASHING
DEPENDING ON CLIMATIC CONDITIONS.
2. UNDERLAYMENT TYPE AND NECESSITY MAY VARY DAPENDING ON CLIMATIC CONDITIONS.
3. THIS DETAIL SHOWS ONE TYPE OF GUTTER SUPPORT. GUTTER SECUREMENT AND SUPPORT
OPTIONS VARY ACCORDING TO REGIONAL PRACTICES AND MANUFACTURERS SPECIFICATIONS.
OPTIONAL STRIPPING
PLY AS SPEC.
GUTTER
AS SPEC.
UNDERLAYMENT AS
SPEC.
''T'' TYPE EDGE METAL
FLASHING AS SPEC.
ASPHALT SHINGLE STARTER
COURSE AS SPEC.
''L'' TYPE EDGE METAL FLASHING
AS SPEC.
GUTTER AS SPEC.
ALTERNATE:
1 PIECE GUTTER
4
EAVE AND RAKE FLASHING DETAIL
NOT TO SCALE
1
EAVE FLASHING WITH GUTTER DETAIL
NOT TO SCALE
3
NOT TO SCALE
2
NOT TO SCALE
UNDERLAYMENT OR ICE DAM
PROTECTION MEMBRANE AS
SPEC.
ASPHALT SHINGLE STARTER
COURSE AS SPEC.
''T'' TYPE METAL EDGE
FLASHING AS SPEC.
''T'' TYPE METAL EDGE FLASHING
AS SPEC.
ASPHALT SHINGLES AS
SPEC.
5
NOT TO SCALE
CHIMNEY FLASHING DETAIL
VENTED RIDGE DETAIL
6
NOT TO SCALE
CLOSED VALLEY DETAIL
EXTEND END OF SHINGLE AT
LEAST 12" BEYOND VALLEY
CENTER LINE. NAIL PUTTING
EXTRA FASTENER IN TOP
CORNER OF SHINGLE AS
SPEC.
CARRY UNDERLAYMENT
AT LEAST 6" OVER LEAK
BARRIER AS SPEC.
EXTEND STARTER
STRIP ACROSS
VALLEY AT LEAST
12" AND WEAVE
WITH OPPOSITE
SIDE STARTER
STRIP SHINGLE AS
SPEC.
CENTER FULL WIDTH ROLL OF
LEAK BARRIER. DO NOT PLACE
FASTENERS WITHIN 6" OF
CENTER LINE. HORIZONTAL
LAPS MUST BE AT LEAST 6" AS
SPEC.
OVERLYING SHINGLES
MUST BE CUT SO THEY ARE
2" AWAY FROM VALLEY
CENTER LINE. CLIP
SHINGLE CORNERS 45
DEGREES TO KEEP WATER
FLOW IN THE VALLEY
CENTER. SEAL THE VALLEY
SINGLE TO EACH OTHER
USING ASPHALT PLASTIC
CEMENT AS SPEC.
OPTIONAL: FASTENERS AS
SPEC.
OPTIONAL: SEALANT UNDER
SHINGLES AS SPEC.
MIN. 4'' UPSLOPE AS SPEC.
MIN. 4'' DOWNSLOPE AS SPEC.
METAL FLASHING SLEEVE AS
SPEC.
ASPHALT SHINGLES AS SPEC.
OPTION:
PRE-FABRICATED
FLASHING AS SPEC.
ASPHALT
SHINGLES
AS SPEC.
7
PENETRATION FLASHING DETAIL
NOT TO SCALE
SHEET METAL
RIDGE CAP AS
SPEC.
SHEET METAL AIR
DAM WITH
WEEPHOLES AS
SPEC.
ASPHALT
SHINGLES AS
SPEC.
UNDERLAYMENT OR ICE DAM PROTECTION
MEMBRANE AS SPEC.
WEATHERPROOF
FLASHING
MEMBRANE AS
SPEC.
RIDGE VENT
MATERIAL AS
SPEC.
RIDGE DETAIL
SPECIFIED
UNDERLAYMENT
OVER PLYWOOD
DECKING AS SPEC.
PREMIUM
HIP/RIDGE
SHINGLES 2 PLY AS
SPEC.
SHINGLES AS SPEC.
EXISTING 5/8" PLYWOOD TO
REMAIN. REPLACE ANY
DAMAGED OR ROTTEN
AREAS AS SPEC.
PLYWOOD AS SPEC.
EXISTING ROOF DECK
PLYWOOD AS SPEC.
EXISTING ROOF DECK
PLYWOOD AS SPEC.
EXISTING ROOF DECK
EXISTING ROOF DECK
PLYWOOD
AS SPEC.
13
NOT TO SCALE
SHINGLE-MATE INSTALLATION DETAIL
SHINGLE-MATE ROOF
DECK PROTECTION AS
SPEC.
ALONG RAKE, PUT
NON-CORROSIVE
METAL DRIP EDGE ON
TOP OF SHINGLE-MATE
ROOF DECK
PROTECTION AS SPEC.
9
NOT TO SCALE
SHINGLE INSTALLATION DETAIL
10
NOT TO SCALE
STEP FLASHING DETAIL
11
NOT TO SCALE
SEAL-A-RIDGE IR RIDGE CAP SHINGLE
12
NOT TO SCALE
PROSTART STARTER STRIP SHINGLE
INSTALLATION DETAIL
CONTINUE WITH
FULL SIZE
STARTER STRIP
SHINGLE AS SPEC.
PLACE SHINGLE
1/4"-3/4" OVER
EAVES AND RAKE
EDGES TO
PROVIDE DRIP
EDGE AS SPEC.
NAIL
APPROXIMATELY
1-1/2"-3" ABOVE
THE BUTT EDGE OF
THE SHINGLE AND
APPROXIMATELY
1"-2" AND 10"-12" IN
FROM OF EACH
SIDE AS SPEC.
FOR MAXIMUM WIND
RESISTANCE ALONG
RAKES, INSTALL
STARTER STRIP OR
CEMENT SHINGLES
TO UNDERLAYMENT
AND EACH OTHER IN
A 4" WIDTH OF
ASPHALT PLASTIC
CEMENT AS SPEC.
OVERLAP EAVES EDGE
STARTER STRIP AT LEAST 3"
AS SPEC.
TRIM 3" FROM END OF FIRST
SHINGLE IF USING 39-3/8"
FIELD SHINGLES AS SPEC.
12"
1/2"
12"
36"
6- 2/3"
ALONG RAKE, PUT SHINGLE-MATE ROOF
DECK PROTECTION ON TOP OF
NON-CORROSIVE METAL DRIP EDGE AS
SPEC.
4
"
E
N
D
L
A
P
PLACE FIRST COURSE
OF SHINGLES 1/4" - 3/4"
OVER EAVE AND RAKE
EDGES, COVERING
STARTER COURSE
OVERHANG, TO
PROVIDE DRIP EDGE
AS SPEC.
SECOND COURSE:
TRIM 6" OFF FIRST
SHINGLE AS SPEC.
THIRD COURSE:
TRIM 11" OFF FIRST
SHINGLE AS SPEC.
FOURTH COURSE:
TRIM 17" OFF FIRST
SHINGLE AS SPEC.
6
"
1
1
"
1
7
"
1. CONTINUE EACH COURSE WITH WHOLE SHINGLES.
2. STRIKE A CHALK LINE ABOUT EVERY 6 COURSES TO CHECK PARALLEL ALIGNMENT WITH EAVES.
5"
5
"
7
-
5
/
8
"
F
I
R
S
T
C
O
U
R
S
E
S
E
C
O
N
D
C
O
U
R
S
E
T
H
R
E
E
C
O
U
R
S
E
F
O
U
R
T
H
C
O
U
R
S
E
F
I
F
T
H
C
O
U
R
S
E
2 NAILS AS SHOWN
1"-2" FROM TOP AS
SPEC.
INSTALL 1 PIECE OF
STEP FLASHING TO
FULLY COVER TOP
HALF OF EACH
SHINGLE AS SPEC.
FIRST COURSE OF
STEP FLASHING
UNDER SHINGLE AS
SHOWN AS SPEC.
SET NEXT SHINGLE IN
A QUARTER-SIZED DAB
OF PLASTIC CEMENT
AS SPEC.
F
I
R
S
T
C
O
U
R
S
E
U
N
D
E
R
L
A
Y
M
E
N
T
A
S
S
P
E
C
.
STEP FLASHING FOR METRIC SIZE
SHINGLES 13-1/4" x 39-3/8" WITH
5-5/8" EXPOSURE
6"
PERFORATION
PLYWOOD AS SPEC.
EXISTING ROOF DECK
6"
U
N
D
E
R
L
A
Y
M
E
N
T
A
S
S
P
E
C
.
SHINGLE
INSTALLATION
START AT EITHER
RAKE AND LAY IN
EITHER DIRECTION
FIRST COURSE:
START WITH FULL
SHINGLE
REMAINING COURSE:
REPEAT THE 1ST-4TH
COURSE INSTRUCTIONS
ON THE REMAINING
COURSES, STARTING THE
FIFTH COURSE WITH A
FULL SHINGLE
AP
PR
OX
4
"
COUNTERFLASHING AT RAKE FLASHING
UNDERLAYMENT TURNED UP WALL MIN. 8
INCHES
SELF-ADHERING UNDERLAYMENT AS SPEC.
REMOVE AND REPLACE ALL ROTTEN AND/OR
DAMAGED FIRE RATED PLYWOOD DECKING.
REFASTEN ALL EXISTING DECKING. REFER TO
GENERAL ROOF NOTES FOR FASTENING
REQUIREMENTS.
SHEET METAL STEP
FLASHING FOR EACH
COURSE OF
SHINGLES
30# ORGANIC FELT
NEW DIMENSIONAL SHINGLES AS
SPEC. COLOR TO MATCH EXISTING
8
NOT TO SCALE
SIDE WALL WITH REGLET DETAIL
ROOFING
DETAILS
R2.01
ISSUES AND REVISIONS
1 6
0 0
A L
L E
N
P A
R K
W A
YH
O U
S T
O N,
T E
X A
S
7 7
0 1
9
02/17/16ISSUED FOR
PERMIT, AND
PRICING
P i t
c h
e d
R
o o
f R
e p
l a
c e
m e
n t
P r
o j e
c t
ALLE
N PA
RKW
AY V
ILLA
GE
+RDC
AT/3
November 1, 2016 Pitched Roofs Replacement Project IFB: APV-16-03
Allen Parkway Village 1600 Allen Parkway Houston, Texas 77019
Responses to Vendor Questions
1. HHA Section 3 Form –What is Solicitation Title and Solicitation # This is the title of the project and IFB Number-Pitched Roof Replacement Project IFB Number APV-16-03... are they? Are these boxes necessary to have filled out with bid packet?It is not necessary but recommend that this section is completed.
2. HUD-5370 Pages 8-23. Warranty of Construction (a) 20 years, 9-27. Payments (d) 22-days , 12-33. Liquidated Damages (a) $500 and 36. Insurance (2) $1,000,000.00, & 13-36. Insurance (3) $1,000,000.00-have blanks to fill in. Are these filled in by the architect or owner after project award or do I fill in at bid time?, The coverage amounts required must be on the COI before contract execution and before Notice to Proceed will be extended to contractor.
3. Good Faith Declaration – Who are the Persons of Interest? Architect, Project Manager, and Owner? - Persons of Interest are the partners for the contractor's firm.
4. WME – By checking these boxes on documents, we are stating we are a WBE. Do we have to submit paperwork to show we are at the time of bid or sometime after? M/WBE form must be completed and submitted with bid, even if you are not an M/WBE
5. Dept. of Housing & Urban Development / Public and Indian Housing Programs – Check all appropriate boxes and sign, correct? Yes