ion-b das commissioning

Upload: roybutcher

Post on 09-Jan-2016

15 views

Category:

Documents


1 download

TRANSCRIPT

0. Project InformationProject Information

USID:XXXXXXSite Name:XXXXXXNamePhoneE-MailSite ID:XXXXXXASG DAS Market EngineerQuickbase Project ID:XXXXXXMarket RAN Design EngineerProject Tracking IDMarket RAN Design ManagerFA Location CodeC&E SRCMRAN OEM (ALU/E///) RAN Integration VendorRAN Integration Vendor POCDAS OEM CommScopeDAS Integration VendorCommScopeDAS Integration Vendor POCDAS Commissioning VendorCommScopeDAS Commissioning Vendor POCRAN Equipment

VersionDateComment

1. CW Test at HE to TFLNSector IDZone IDTest CaseStart PointEnd PointTX CW Downlink Power (dBm)TX CW Downlink Test Frequency (MHz)Measured Average Downlink Signal Level (dBm)Estimated Downlink Loss I-POI (dB)=F-JTX CW Uplink Power (dBm)TX CW Uplink Test Frequency (MHz)Measured Average Uplink Signal Level (dBm)Estimated Uplink Loss (dB)=D-HNotes

111900 MHz CW TX Power (dBm)DAS TrayTFLN10.11950-10-20.1-151870-35-20Measured at TLCN4 DL cable output (just before the TFLN)11850 MHz CW TX Power (dBm)11700 MHz Path 1 CW TX Power (dBm)11700 MHz Path 2 CW TX Power (dBm)

221900 MHz CW TX Power (dBm)22850 MHz CW TX Power (dBm)22700 MHz Path 1 CW TX Power (dBm)22700 MHz Path 2 CW TX Power (dBm)

231900 MHz CW TX Power (dBm)23850 MHz CW TX Power (dBm)23700 MHz Path 1 CW TX Power (dBm)23700 MHz Path 2 CW TX Power (dBm)

2. CW Test from TFLN to Remote Sector ID Zone IDRemote IDTest CaseTX Downlink Power (dBm)Test Frequency (MHz)Estimated Average Downlink Signal Level (dBm)Downlink Pass/Fail Threshold (dB)1111900 MHz CW TX Power (dBm)-519562525111850 MHz CW TX Power (dBm)111700 MHz Path 1 CW TX Power (dBm)111700 MHz Path 2 CW TX Power (dBm)

1121900 MHz CW TX Power (dBm)112850 MHz CW TX Power (dBm)112700 MHz Path 1 CW TX Power (dBm)112700 MHz Path 2 CW TX Power (dBm)Insert Walk Test Plots

3. Minimize DAS UL NoiseSector IDTest PointFrequency Band (MHx)Technology ReferenceBase Station Cabinet/RRU IDCable ID / DAS Interface IDNumber of Remotes/SectorCalculated Noise Floor (dBm)Measured Noise Floor (dBm)Attenuation Parameter AdjustmentAttenuation Parameter AdjustmentAttenuation Parameter AdjustmentNotes1RAN CableCell 850UMTS 3.84MHz13-100.4-101.1-81RAN CablePCS 1900UMTS 3.84MHz13-100.6-101.3-131RAN Cable700LTE 10MHz13-100.4-101.2-13

222

333

4. Noise Floor MeasurementsTest PointFrequency Band (MHz)Power Measurment BandwidthSector IDBase Station Cabinet/RRU IDCable ID / DAS Interface IDNumber of Remotes/SectorMeasured Noise Floor (dBm)NotesPOI UL PortCell 850UMTS 3.84MHz113-101POI UL PortPCS 1900UMTS 3.84MHz1POI UL Port700LTE 10MHz1

5. Call ProcessingCall/Session Type UE Device Type/ModelTechnologyFrequency BandCall/Session DurationCall/Session Log NotesSector IDPhoneCompanyNotesCSUMTSPS - Data SessionUMTSPS - Ping TestUMTSCSLTE w/ UMTS FallbackPS - Data SessionLTE PS - Ping TestLTE

6. TPOI and POI SettingsSector IDBand/TechnologyDL DAS Interface SettingsUL DAS interface SettingsDL TPOI SettingsUL TPOI SettingsNotes

11900 MHz UMTS1850 MHz UMTS1700 MHz Path 1 LTE1700 MHz Path 2 LTE

7. DeliverablesDeliverable:Deliverable Type: Delivered by:Delivered to:Location (link to folder/files)PhoneCompanyNotesDAS System ConfigurationRedline ModificationsRFDS Plumbing DiagramsRedline ModificationsGSM/UMTS/LTE BTS, NodeB, and/or eNodeB equipmentPhotosSplice Box locationsPhotosFiber Patch PanelPhotosRemote Equipment Locations (i.e. IDF, MDF, IT closets, storage rooms, etc)Photos (anotated with remote ID)Antenna locationsPhotos (anotated with antenna ID)Cable trays/raceways/wire management systemsPhotos (anotated with cable route descriptors)