ion beam analysis today and tomorrow ferenc pászti research institute for particle and nuclear...

35
Ion Beam Analysis Ion Beam Analysis Today and Tomorrow Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Upload: gerard-pierce

Post on 04-Jan-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Ion Beam Analysis Today Ion Beam Analysis Today and Tomorrowand Tomorrow

Ferenc PásztiResearch Institute for Particle and Nuclear

Physics, Budapest

20+5 min

Page 2: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min
Page 3: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Accelerators

- Used ones (5 MeV VdG, …)

- Smaller and cheaper (200 keV FIB, …)

- Special designs (3 MeV Tandem)• Radioactive sources (planetary research)• Beam size

- Normal (1x1 mm2)

- Microbeam (1x1 m2)

The incident beam

Page 4: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

5 MeV Van de Graaff Accelerator (EG-2R) at RIPNP, Budapest

Page 5: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

1MeV tandem at Cambridge (GC¯AMS)

B. J. Hughey, Nucl. Instr. Meth. B 172 (2000) 40.

Page 6: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

http://www.culture.gouv.fr/culture/conservation/fr/methodes/aglae.htm

2MeV Tandem at Louvre Paris (AGLAE)

Page 7: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

RBSRBS

Page 8: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements heavier than the ion

Isotopes for light elements • Depth of analysis few 100nm (few m) • Depth resolution few 10nm (few Å) • Sensitivity few at% (light) -

few 100 ppm (heavy)

Main parameters

Page 9: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

RBS spectra (3.045 MeV 4He) of Co implanted Si and a porous Si.

Channel Number

200 300 400 500 600 7000

250

500

750

1000

1250

1500

O

Si

Co

b)

RT LT

Yie

ld (

coun

ts/c

h.)

Channel number

100 200 300 400 5000

500

1000

1500

2000

2500

3000

3500

a)

Si in porous Si

O in porous SiO in buried SiO

x

O resonance peak at the surface

Background

SiO

x

buri

ed

SiP

orou

s

SiPur

e

CoS

i 2

Si in buried SiOx

Si in pure Si

Si in CoSi2

Co in CoSi2

Si PS

Yie

ld (

coun

ts/c

h.)

A.R.Ramos, Nucl. Instr. Meth. B 178 (2001) 283.

Page 10: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

ERDERD

Page 11: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Absorber foil• Kinematics • Coincidence • Element identification (E-E, TOF-E,

ExB…)• …

Suppressing the scattered ions

Page 12: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements Lighter than the ion Isotopes for light elements• Depth of analysis few 100nm• Depth resolution few 10nm (few nm) • Sensitivity few 0.1% (few ppm)

Main parameters

Page 13: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

J. Russel, Mat. Sci. Eng. R 38 (2002) 107.

ERD spectrum from a thin, 200 Å, deuterated polystyrene film

Page 14: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

H. Timmers, Nucl. Instr. Meth. B 190 (2002) 393.

2D ERD spectra from a GaN film with impurities (200 MeV Au ions, E-E gas detector)

Page 15: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

NRANRA

Page 16: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Ions (p, d, , …)

Positive Q value, filter foil• n or

Special detectors

Suppressing the scattered ions

Page 17: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements specific

Isotopes specific• Depth of analysis few 10nm - few m• Depth resolution few nm - few m - ∞• Sensitivity few ppm

Main parameters

Page 18: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

M.E.Varela, Geochimica et Cosmochimica Acta 64 (2000) 3433

12C(d,p)13C NRA spectra of olivine with 1000 ppm C content (1.45 MeV d, 9 m Al filter foil)

Page 19: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

PIXEPIXE

Page 20: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements heavier

Isotopes no• Depth of analysis few m• Depth resolution no• Sensitivity few % - few 10 ppm

Main parameters

Page 21: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

S.B. Reddy, Nucl. Instr. Meth. B in print

PIXE spectra taken from tissues of thyroid

NormalAdenoma

Cancer

Page 22: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

ChannelingChanneling

Page 23: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Basic principle of channeling

Page 24: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

A. Manuaba, Nucl. Instr. Meth. B (2001) 63

Channeling RBS spectra of He and N-implanted and annealed Si. Virgin and random spectra are also included.

(1016 ion/cm2 units)

Page 25: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

E. Alves, Nucl. Instr. Meth. B 106 (1995) 429

Lattice localization of Er in sapphire by RBS/channeling

Page 26: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

MicroprobeMicroprobe

Page 27: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

J. Tajima, Nucl. Instr. Meth. B 181 (2001) 44.

Schematic diagram of the 200 kV FIB microprobe at Osaka University. 80 nm lateral resolution, Si, Be Au ions.

Page 28: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Y.K. Park, Nucl. Instr. Meth. B 158 (1999) 487.

Secondary electron and RBS mapping images by the FIB

microprobe.

300 keV Be2+

Page 29: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

FutureFuture

Page 30: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

New accelerators for IBA

• Cheaper and smaller accelerators for routine applications• Larger used machines (HI-ERDA) • Better microprobes •Transportable IBA?

Page 31: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Unique features

• Channeling for damage profiling and lattice localization• H depth profiling• Atomic depth resolution• Extreme sensitivity

Page 32: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

New methods appear• Pore structure determination by resonance method• Combination of TOF-RBS and TOF-SIMS by a

nanoprobe• …

Page 33: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

F. Pászti, Vacuum. 50 (1998) 451.

R-BS spectra on columnar porous Si (3045+100 keV 4He+). The peak is due to 16O(,) resonance.

At tilt 0° the beam is parallel to the pores.

Page 34: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

F. Pászti, Nucl. Instr. Meth. B 161-163 (2000) 963.

Half-width of the resonance peak for samples implanted at various tilts and fluencies.

Solid lines are fitted Lorentzian curves.

Page 35: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

K. Iwasaki, Nucl. Instr. Meth. B 190 (2002) 296.

TOF spectra by the 200keV FIB. H, O, C peaks are due to secondary ions accelerated by the 1.8 kV

detector bias of the MCP (TOF-SIMS).

As implanted SiO2

As implanted Si

25 nm Au on Si

200 keV Si2+