is 9582-1 (1980): single-phase electric motors for ...is : 9582 ( part i ) - 1980 1.2 the motors...

11
Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 9582-1 (1980): Single-phase electric motors for definite purposes, Part 1: Domestic laundry machine motors [ETD 15: Rotating Machinery]

Upload: others

Post on 15-May-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Disclosure to Promote the Right To Information

Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

इंटरनेट मानक

“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda

“Invent a New India Using Knowledge”

“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru

“Step Out From the Old to the New”

“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan

“The Right to Information, The Right to Live”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam

“Knowledge is such a treasure which cannot be stolen”

“Invent a New India Using Knowledge”

है”ह”ह

IS 9582-1 (1980): Single-phase electric motors for definitepurposes, Part 1: Domestic laundry machine motors [ETD 15:Rotating Machinery]

IS : 9582 ( Part I ) - 1980

Indian Standard SPECIFICATION FOR

SINGLE-PHASE ELECTRIC MOTORS FOR DEFINITE PURPOSES

PART I DOMESTIC LAUNDRY MACHINE MOTORS

Rotating Machinery Sectional Committee, ETDC 15

Chairman

SARI S. G. RA~ACEANDRA

Members

Representing

Kirloskar Electric Co Ltd, Bangalore

SHRI M. GANESH ( Alternate to Shri S. G. Ramachandra )

SHRI R. S. ARORA Directorate’ General of Supplies & Disposals, New Delhi

SHRI K. L. G~ao ( Alternate ) SHRI P. R. BAPAT Guest, Keen, Williams Ltd, Bombay

SHRI A. S. ABHYANKAR ( Alternate ) SHRI S. S. BIJALANI

SHRI A. G. DOSHI ( Alternate ) Walchandnagar Industries Ltd, Walchandnagar

CHIEF EN’QINEI~R ( B ), 11 Central Public Works Department, New Delhi SURVEYOR OR WOBKS 11 ( A~tsra& )

THE:;;;;~~ ( H. B. D. 1 ) Central Electricity Authority, New Delhi DIRECTOR

( H. E. D. 1 ) ( Alternate) SERI D. P. GUPTA Directorate General of Technical Development,

New Delhi SHRI L. GOPALAKRISENAN ( Alternate )

JOINT DIRECTOR STANDARDS Railway Board, Ministry of Railways ( ELECT )-2

DEPUTY DIRECTOR STANDARDS ( ELECT )/B-l ( Alternate )

SHRI P. G. MATHU~ Army Headquarters ( Engineer-in-Chief’ Branch ),

SHRI VIDYA BHUSHAN ( Alternate ) Ministry of Defence

SHRI B. MUKEOPADHYAY National Test House, Calcutta SHRI SANATH KUMAR ( Alternate )

SHRI J. M. NAIK Millowners’ Association, Bombay SHRI S. SARUP ( Alternate )

SHRI Salv NAKAYANA Bharat Heavy Electricals Ltd, Hyderabad SHRI S. C. MUKHOPADHYAY ( Alternate I ) SHRI S. S. RAO ( Alternate II )

( Continued on Page 2 )

@ Copyright 1980 INDIAN STANDARDS INSTITUTION

This publication is protected under the Indian Copyright Act ( XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.

IS : 9582 ( Part I ) - 1980

( Continued from page 1 )

Members Representing

SHBI J. S. NEW Jyoti Ltd, Vadodara SERI P. L. PRADHAN ( ANcrnale )

~~ M. S. PADBIDRI Hindustan Brown Bovcri Ltd, Bombay SARI N. SUNDARA R&JAN ( Alternate )

DR G. M. PHADKE Indian Elrctrical Manufacturers’ Association Bombay

SHRI V. RA~AS~~AXY Siemens India Ltd, Bombay SHRI S. N. GHOSH ( Alkrnatr )

SHRI RAMESE CHANDRA Delhi Electric Supply Undertaking, New Delhi SHRI P. DUTTA ( Alternate )

SBBI A. K. RAN~NEKAR Tata Consulting Engineers, Bombay SJIRI M. E. REDDY ( Ahrnafr )

SHRI P. K. SAXENA Rural Electrification Corporation Ltd, New Delhi SHRI G. L. DUA ( Altrrnatc )

SHRI G. B. SINoH Steel Authority of India Ltd, New Delhi SHBI P. C. SENCXJPTA ( Altcmalc )

LT-COL A. K. SRIVASTAVA Ministry of Dcfence ( DGI ) MAJ V. B. DESHMUKH ( Altsmatc )

SHEI A. N. SRIVATHSA NGEF Ltd, Bangalore SHRI S.L. SRIDHARA

MURTEY ( Allcrnatc ) SHRI R. K. TASKAR Crompton Grcaves Ltd, Bombay

SHRI D. P. PATEL ( Altcmalc ) SHRI J. S. ZAVEBI Bharat Bijlec Ltd, Bombay

SHRI S. G. DESHYUKH ( Alfrrnatc ) SHRI S. P. SACHDEV,

Director (Alec tech ) Director General, IS1 ( &-o&o Me&r )

SHRI R. K. MONQA Deputy Director ( Elec tech ), IS1

Small Motors Subcommittee, ETDC 15 : 2

c ORDCrlCl SHRI R. K. TASKAR

Members

Crompton Greavcs Ltd, Bombay

SERI R. N. KASTURY ( Aflcrnatr to Shri R. K. Taskar )

SHEI V. R. DAKSHINA MURTHY Ralliwolf Ltd, Bombay SHRI D. I. KEUSHALANI ( Alfcrnate )

SHRI H. K. DIVEKAR SHRI A. N. GHOSX

Bhangar Bros C Co Pvt Ltd, Bombay Development Commissioner ( Small Scale Indus_

tries ), New Delhi SHRI A. BONDOPADHYA ( Alternate )

SEEI S. JAGADESAN Coimbatore District Small Stall Industries Associa- tion, Coimbatore

DB S. BALAKRISHNAN ( Altematr ) ,

( Continued on page 6 )

2

IS t 9582 ( Part I ) - 1980

Indian Standard SPECIFICATION FOR

SINGLE-PHASE ELECTRIC MOTORS FOR DEFINITE PURPOSES

PART I DOMESTIC LAUNDRY MACHINE MOTORS

0. FOREWORD

0.1 This Indian Standard ( Part I ) was adopted by the Indian Standards Institution on 28 August 1980, after the draft finalized by the Rotating Machinery Sectional Committee had been approved by the Electrotech- nical Division Council.

0.2 The general requirements of single-phase electric motors are covered in IS : 996-1979* which is a necessary adjunct to this standard. This standard has been prepared with a view to cover the special requirements of single-phase motors for the specific application in domestic laundry machines.

0.3 The requirements of domestic laundry machines are given separately in IS : 6390-197lt.

0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test, shall be rounded off in accordance with IS : 2-1960$. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

1. SCOPE

1.1 This standard (Part I) covers motors for domestic laundry machines which provides power for driving a domestic electric clothes washing machine, dryer or combination of washer and dryer.

*Specification for single-phase small ac and universal electric motors ( second rUuiJiOn ).

tSpecification for domestic electric clothes washing machine ( non-automatic ). $Rules for rounding off numerical values ( revised ).

3

IS : 9582 ( Part I ) - 1980

1.2 The motors covered by this standard may have windings with Class A, Class E or Class B insulations ( see IS : 1271-1958* ).

2. TERMINOLOGY

2.1 For the purpose of this standard, the definitions given in 2 of 1s : 99d-19797 shall apply.

3. TYPE OF MOTOR

3.1 The motor for domestic laundry machines shall be one of the follow- ing types, and having windings with Class A, Class E, Class B or Class F insulation ( see IS : 1271-1958* ):

a) Split phase motor,

b) Capacitor start induction run motor,

c) Capacitor start and capacitor run motor ( Two Value Capacitor Type ),

d) Parmanent-split capacitcr motor ( for dryers only ),

e) Universal motor, and

f) ac series motors.

4. VOLTAGE, FREQUENCY, OUTPUT AND SPEED RATINGS

4.1 Voltage Rating - The provisions of 7.1 and D-2 of IS : 996-19797 shall apply.

4.2 Frequency - The provisions of 7.2 and D-2 of IS : 996-19797 shall

apply.

4.3 Output Ratings - Preferred output ratings of the motor shall be 125, 200, 250 and 370 watts.

4.4 Speed - Motors shall be single speed or multi-speed pole changing type. Preferred slip shall be 7 percent.

5. DIMENSIONS

5.1 The provisions of 9 of IS : 996-19797 shall apply.

6. TYPE OF ENCLOSURE

6.1 The provisions of 4 of IS : 996-1979 shall apply?.

*Classification of insulating materials for electrical machinery and apparatus in relation to their thermal stability tn service.

tSpcci&ation for single-phase small ac and universal electric motors ( srrond revision ).

4

IS : 9582 ( Part I ) - 1980

7. GENERAL CONSTRUCTION

7.1 The requirements of 6 of IS : 996-1979” shall apply.

8. GENERAL CHARACTERISTICS

8.1 The provisions of 12 of IS : 996-1979* shall apply.

9. TEtiMINAL MARKINGS

9.1 The provisions of 13 of IS : 996-1979* shall apply.

10. MARKING AND DIAGRAM OF CONNECTION

10.1 The provisions of 14 of IS : 996-1979* shall apply except 14.1(a) which shall be substituted by:

a) Reference to this Indian Standard, that is, Ref. ISS 9582

11. TESTS

11.1 The provisions of 15 of IS : 996-1979* shall apply.

*Specification for single*phase small N and universal electric motors ( srcond nuision ) ,

IS t 9582 ( Part I ) l 1980

( Co&turd from page 2 )

Msmbrrs Reprrsmtiag

SERI M. L. JEA SHRI Asrrox A. KULKARNI

General Radio and Appliances Ltd, Bombay

SHRI G. S. POTDAR ( Alfrm~tr ) Kulkarni-Black St Decker Ltd, Shirol

Paos A. K. MEHTA Kclvinator of India Ltd, Faridabad SRBI V. S. CEANDRASEKHAII ( Altrrnata )

SHBI P. V. MEHTA All India Electric Motor Manufacturers’ Associa-

SERI DHRUV M. NAIK ( Altrmatr ) tion, Bombay

SERI N. K. MUKHERJEE Weights and Measures Syndicate, Howrah SRRI B. MUKIIOPADHYAY National Test House, Calcutta

SHBI D. N. UPADHYAY ( Aknote ) SHBI E. N. NARAYANASWAYY Directorate of Industrier & Commerce, Madras

SERI L. ARU~~~AM ( Altwnatr ) SHBI ROBHAN LAL Directorate General of Supplies & Disposals Ltd,

New Delhi SEBX S. G. SATEWAR American Universal Electric

New Delhi ( India ) Ltd,

SHRI K. A. GOEL ( Altmraatr ) Da V. K. SBINIVASAN Kirloskar Electric Ltd, Bangalore

SHRI V. B. GHANEKAR ( Ahnatc ) SHBI V. SWAMINAT~~N Electronics Ltd, New Delhi

SERI H. K. A~A~WAL ( Alfrrnafr )

6

17 -- \

AMENDMENT NO. 1 JANUARY 1990 , TO

IS : 9582 ( Purt 1) - 1980 SPECIFICATION FOR SINGLE-PHASE ELECTRIC NIOTORS

FOR DEFINITE PURPOSES

PART 1 DOMESTK LAUNDRY MACHINE MOTORS

( Page 3, clause 0.3 ) - Substitute ‘IS 6390 : 1983t’for ‘1s : 6390-1971t’.

( Page 3, foot-note marked with ‘t’ mark ) - Insert at the end ‘(first revision )‘.

( Page 4, clauses 1.2 and 3.1 ) ‘IS : 1271-1958+‘.

- Substitute ‘IS 1271 : 1985*’ for

( Page 4, foot-note marked with ‘*’ mark ) - Substitute the following for the existing foot-note:

*Thermal evaluation and classification of electrical insulation (firsf revision ).’

[ Page 4, clause 3.1(d) ] - Delete the words ‘( for dryers only )‘.

[ Page 4, clause 3.1(f) ] - Insert the following at the end:

‘NOTi? -Adequate precautions shall be taken by the laundary machine manufacturers to ensure that permanent split capacitor motor selected for the machine develops adsquate torque for the job application.’