is jet brochure 11-23-14 - industrial steam...tank diameter x overall length rated capacity system...

4
Pressurized and Atmospheric Deaerators industrialsteam.com Jet Spray .005 cc/Liter Pressurized Deaerator Spray Type Deaerator Pressurized .005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of .005 cc/liter from 5% to 100% of deaerator capacity.

Upload: others

Post on 03-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Pressurized and Atmospheric Deaerators

    industrialsteam.com

    Jet Spray .005 cc/Liter Pressurized DeaeratorSpray Type DeaeratorPressurized .005 cc/literCOUNTER FLOW TRAY design providesguaranteed removal of all dissolved oxygenin excess of .005 cc/liter from 5% to 100%of deaerator capacity.

  • Components and Sizing

    1 High Water Alarm Switch2 Make-up Nozzle3 Y-Strainer4 Pressure Control Valve5 Steam Nozzle6 Make-up Control Valve7 Level Controller8 Boiler Feed Pump Motor9 Boiler Feed Pump10 Make-up Ball Valve11 Make-up Globe Valve12 Pressure Gauge (0-15#) w/cock

    13 Temperature Gauge w/thermowell (50 DEGREE - 500 DEGREE F)14 Safety Relief Valve (Set at 50#)15 Sentinal Relief Valve (Set at 20#)16 Sight Glass Assembly17 Overflow Trap18 Low Water Alarm & Cut Off Switch19 Recirculation Orifice Union20 Recirculation Ball Valve21 Suction Coupling22 Suction Gate Valve23 Drain Ball Valve

    24 Vent Gate Valve25 Level Transmitter26 Make-up Y-Strainer27 Recirculation Check Valve28 Starter29 Control Panel (NEMA 1)30 Water Column Drain Ball Valve31 Water Column Isolation Ball Valve32 Chemical Feed Quill33 Discharge Pressure Gauge (0-400#)34 Discharge Ball Valve35 Discharge Check Valve

    • Consult Factory for systems over 300,000 lbs./hr. • Weights do not include pumps or optional equipment * Includes 48" Stand ** Includes Control Panel

    LBS/HR HP GALS HEIGHT* L W** SHIPPINGMIN.MODEL

    NUMBER

    RECEIVER SIZETANK

    Diameter x OverallLength

    RATEDCAPACITY

    SYSTEM CAP.TO OVERFLOW

    APPROX OVERALLDIMENSIONS, in.

    APPROX WEIGHT,lbs

    1JS52JS53JS54JS56JS58JS510JS512JS515JS518JS521JS524JS530JS536JS545JS560JS575JS590JS5

    36" x 5' 5"36" x 5' 5"48" x 5' 10"48" x 5' 10"48" x 7' 10"54" x 9' 11"54" x 9' 11"60" x 10' 4"60" x 12' 4"60" x 14' 4"66" x 14' 4"66" x 16' 4"72" x 16' 4"72" x 18' 7"84" x 16' 11"84" x 18' 11"96" x 19' 3"96" x 23' 3"

    3,4506,90010,35013,80020,70027,60034,50041,40051,75062,10072,45082,800100,000125,000150,000200,000250,000300,000

    100200300400600800

    1,0001,2001,5001,8002,1002,4003,0003,6004,5006,0007,5009,000

    1551552852854136976978661060125414501658201025182990400050466170

    2111.113.910.310

    12.610.110.410.310.110

    10.110

    10.11010

    10.110.3

    9292102102102108108112112112112118124124136136148148

    6565656594119119124148172172196199223203227231279

    140014002000200024000310031003600385041004800530060006550810090001020012100

    OPERATING FLOODED

    27002700440044005500840084001080012650145001680019200225002520032300406005220063600

    3500350060006000756011800118001500017650203002450027900296003310041000514006600080500

    48486060606666727272787884849696108108

    Jet Spray DeaeratorPressurized .005 cc/liter

    FEATURES

    UNIQUE JET SPRAY scrubber design guaranteesremoval of all dissolved oxygen in excess of .005 cc/liter (7 ppb).

    ELECTRONIC INSTRUMENTATION FOR MODULATINGLEVEL CONTROLincludes a HART compatible differential pressure transmitter,PID controller, and motorized control valve. MULTIPLE CONFIGURATIONS: vertical or horizontal vessels provide maximum flexibility using minimum footprint. ONLY STAINLESS STEEL components come in contactwith undeaerated water. Spray nozzle, scrubbing sectionand internal vent condenser are all stainless steel. A.S.M.E. Code and National Board stamped receiversat 50 psi is standard. Standard vessel optionsinclude stress relieving, non-destructive testingand full vacuum. CUSTOM ENGINEERED PACKAGED SYSTEMincludes boiler feedwater pumps and qualitycomponents to insure reliable service.

    Testing RequirementsThis system requires steady state conditions per the ABMAtesting procedure.

    *Requires surge tank

    100% Makeup0% condensate Yes

    30% Makeup70% condensate

    High Pressurecondensate returns

    100% Turndown

    Load Swings

    When to use

    industrialsteam.com

  • Components and Sizing

    1 High Water Alarm Switch2 Make-up Nozzle3 Y-Strainer4 Pressure Control Valve5 Steam Nozzle6 Make-up Control Valve7 Level Controller8 Boiler Feed Pump Motor9 Boiler Feed Pump10 Make-up Ball Valve11 Make-up Globe Valve12 Pressure Gauge (0-15#) w/cock

    13 Temperature Gauge w/thermowell (50 DEGREE - 500 DEGREE F)14 Safety Relief Valve (Set at 50#)15 Sentinal Relief Valve (Set at 20#)16 Sight Glass Assembly17 Overflow Trap18 Low Water Alarm & Cut Off Switch19 Recirculation Orifice Union20 Recirculation Ball Valve21 Suction Coupling22 Suction Gate Valve23 Drain Ball Valve

    24 Vent Gate Valve25 Level Transmitter26 Make-up Y-Strainer27 Recirculation Check Valve28 Starter29 Control Panel (NEMA 1)30 Water Column Drain Ball Valve31 Water Column Isolation Ball Valve32 Chemical Feed Quill33 Discharge Pressure Gauge (0-400#)34 Discharge Ball Valve35 Discharge Check Valve

    • Consult Factory for systems over 300,000 lbs./hr. • Weights do not include pumps or optional equipment * Includes 48" Stand ** Includes Control Panel

    LBS/HR HP GALS HEIGHT* L W** SHIPPINGMIN.MODEL

    NUMBER

    RECEIVER SIZETANK

    Diameter x OverallLength

    RATEDCAPACITY

    SYSTEM CAP.TO OVERFLOW

    APPROX OVERALLDIMENSIONS, in.

    APPROX WEIGHT,lbs

    1JS52JS53JS54JS56JS58JS510JS512JS515JS518JS521JS524JS530JS536JS545JS560JS575JS590JS5

    36" x 5' 5"36" x 5' 5"48" x 5' 10"48" x 5' 10"48" x 7' 10"54" x 9' 11"54" x 9' 11"60" x 10' 4"60" x 12' 4"60" x 14' 4"66" x 14' 4"66" x 16' 4"72" x 16' 4"72" x 18' 7"84" x 16' 11"84" x 18' 11"96" x 19' 3"96" x 23' 3"

    3,4506,90010,35013,80020,70027,60034,50041,40051,75062,10072,45082,800100,000125,000150,000200,000250,000300,000

    100200300400600800

    1,0001,2001,5001,8002,1002,4003,0003,6004,5006,0007,5009,000

    1551552852854136976978661060125414501658201025182990400050466170

    2111.113.910.310

    12.610.110.410.310.110

    10.110

    10.11010

    10.110.3

    9292102102102108108112112112112118124124136136148148

    6565656594119119124148172172196199223203227231279

    140014002000200024000310031003600385041004800530060006550810090001020012100

    OPERATING FLOODED

    27002700440044005500840084001080012650145001680019200225002520032300406005220063600

    3500350060006000756011800118001500017650203002450027900296003310041000514006600080500

    48486060606666727272787884849696108108

    industrialsteam.com

  • Pressurized and Atmospheric Deaerators

    industrialsteam.com

    Jet Spray .005 cc/Liter Pressurized DeaeratorSpray Type DeaeratorPressurized .005 cc/literCOUNTER FLOW TRAY design providesguaranteed removal of all dissolved oxygenin excess of .005 cc/liter from 5% to 100%of deaerator capacity.

    Have questions or need help specifying this equipment? Email: [email protected]

    Need help with an existing system or parts? Email: [email protected]

    Looking for a local representative? Email: [email protected]

    Literature available for download at industrialsteam.com

    Spray Flow I I.005 cc/Liter AtmosphericRecycling Deaerators

    Pressurized and Atmospheric Deaerators

    industrialsteam.com

    Industrial Steam1403 SW 7th Street, Atlantic, Iowa 50022TEL (712) 243-5300 FAX (712) 243-3440

    Additional Industrial Products

    Tray TypePressurized .005 cc/literPressurized Deaerators

    Steam Flow.005 cc/Liter PressurizedRecycling Deaerators

    Blowdown HeatRecovery Systems,Blowdown Separators