is your hplc column protected? - phenomenexphx.phenomenex.com/lib/5721_us.pdf · gemini®-nx (c18...

8
Is your HPLC column protected?

Upload: docong

Post on 26-Sep-2018

240 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

Is your HPLC column protected?

Page 2: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

� Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

UNIV

ER

SAL FIT • PATENTEDDESIGN

CONN

ETTORE UNIVERSALECONNECTEUR UNIVERSEL

SECURITYGUARD BREVETTATO

DECONCEPTION BREVETÉE

SecurityGuard™ Cartridge System

• Extends HPLC column lifetime

• Won’t alter chromatography

• Compatible with all HPLC columns

• Easy to determine when to change cartridge

• Easy to use

“ We have been using SecurityGuard on all our HPLC systems and it has been very helpful in extending column lifetime.”

— V. Agarwal

Page 3: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

�Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

Cut-away view showingCartridge – can be easily inspected for contaminants

Universal fingertight connection to HPLC column - no wrenches required

How does SecurityGuard™ work?

The SecurityGuard analytical cartridge holder directly fingertightens into virtually any manufacturer’s column with a female/inverted endfitting.

Contaminants are retained by an inexpensive disposable cartridge instead of damaging your valuable HPLC column investment.

Contaminants Trapped

Compounds of InterestCompounds of Interest

ContaminantsContaminants

HP

LC C

olumn

From Injector

Guard

Cartrid

ge System

“ This product provides the insurance we need to use our analytical columns for intense production analysis. The SecurityGuard is easy to use and cartridge replacement is simple.”

— T. Sollima

Page 4: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

� Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

Featureappliestoanalytical-sizedguardsystem only,anddoesnotapplytoSemiPREPorPREP guardcartridges.

Fits any manufacturer’s HPLC column!

The floating outlet from the analytical SecurityGuard™ holder fits into virtually ANY manufacturer’s column with a female/inverted endfitting, making it a truly universal guard system.

SecurityGuard is designed to effectively protect all your valuable HPLC columns.

SecurityGuard is a universal direct-connect holder. The universal fit patented design has a floating outlet that automatically adjusts to the precise port depth of any manufacturer’s analytical HPLC column. This ensures a low-dead volume, leak-free connection, without the use of unions or adapters, no matter which manufacturer’s column you’re using.

Universal Fit Patented Design

“ SecurityGuard is easy to use, works perfectly with Dionex column and helps us to extend column life.”

—J. Pandiscas

Page 5: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

�Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

min0

mAU

0

100

200

300

400

500

5 10 15 20 25 30

min0

mAU

0

100

200

300

400

500

5 10 15 20 25 30

min0

mAU

0

100

200

300

400

500

5 10 15 20 25 30

min0

mAU

0

100

200

300

400

500

5 10 15 20 25 30

Will SecurityGuard™ alter my chromatography like traditional

guard columns?no. SecurityGuard can protect your valuable HPLC column from the damaging effects of chemical contaminants and microparticulates, without altering your chromatography results.

The short 4 mm analytical cartridges have virtually no effect on efficiency, retention time, or backpressure. This protection can lead to an extension of column life.

With SecurityGuardWithout SecurityGuard

Column: Symmetry®�.�µmC181�0x�.6mmGuard Cartridge: SecurityGuardC18(ODS)�x�.0mmIDMobile Phase: 0.1MAmmoniumacetate/Acetonitrile/ Methanol(��:��:�0)Flow Rate: 0.6mL/minDetection: UV@���nmSample: 1.Clonazepam �.Oxazepam �.Diazepam �.Bromazepam �.Temazepam 6.Medazepam

App

ID 1

0730

Compare - Virtually No Change

vs.

Page 6: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

6 Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

Column Protection

Does not alter your chromatography

One holder works with all columns (no coupler required)

Ability to double stack cartridges for added protection

Visually inspect for contaminants

Inexpensive replacement

Traditional

Analytical

guard column ‡Analytical

SecurityGuard

System

‡ Traditional Analytical Guard column refers to: Stainless Steel hardware in 30 x 4.6 mm.

vs.

How do I know when to replace my cartridges?

Patented * “see your dirt” feature lets you know exactly when it’s time to replace your cartridge.

The SecurityGuard™ cartridge’s clever design eliminates the frustration and guesswork of when to change your guard column.

The direct-view feature gives you the opportunity to visually inspect the surface of the cartridge’s packing material any time, without disturbing the packing bed. Now you can easily monitor visual contaminant build-up, and change your guard cartridge before it’s too late!

There are many added benefits using SecurityGuard to protect your HPLC column investment.

DirtyIf either discoloration or particle build-up is observed, it’s time to replace the cartridge.

CleanIf it looks clean, the cartridge may be reinserted for further use.

It’s clear!

“ The visible indicator is a great tool to help gauge when to change the guard cartridge.”

— P. A.

If your contaminants are colorless, replace the cartridge as often as needed to maintain chromatographic performance.* Feature applies to analytical-sized guard system only, and does

not apply to SemiPREP or PREP guard cartridges.

Page 7: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

�Phenomenex Tel: (310) 212-0555 Fax: (310) 328-7768 Email: [email protected] Web: www.phenomenex.com/securityguard

CleanIf it looks clean, the cartridge may be reinserted for further use.

Choosing your column protection is easy!

2.0-3.0

4.0 x 2.0

3.2-8.0

4.0 x 3.0

9.0-16.0

10.0 x 10.0 15.0 x 21.2 15.0 x 30.0

18.0-29.0 30.0-49.0

ANALYTICAL SEMIPREP PREP

If your HPLC column ID (mm) is:

Use Cartridges (mm):

Material Description pH Stability

Cartridges for General Purpose/PharmaceuticalC18 (ODS,Octadecyl) 1.�-10 AJ0-4286 AJ0-4287 AJ0-7221 AJO-7839 AJO-8301

C12 (Dodecyl) 1.�-10 AJ0-6073 AJ0-6074 AJ0-7275 AJO-7842 AJO-8304

C8 (MOS,Octyl) 1.�-10 AJ0-4289 AJ0-4290 AJ0-7222 AJO-7840 AJO-8302

C5 (Pentyl) 1.�-10 AJ0-4292 AJ0-4293 AJ0-7372 — —

C1 (TMS) �-9 AJ0-4298 AJ0-4299 AJ0-7373 — —

Silica — — AJ0-4347 AJ0-4348 AJ0-7223 AJO-7229 AJO-8312

HILIC HILIC 1.�-8 AJ0-8328 AJ0-8329 — — —

NH2 (Amino,Aminopropyl) 1.�-11 AJ0-4301 AJ0-4302 AJ0-7364 AJ0-8162 AJO-8309

CN (Cyano,Cyanopropyl) �-�.� AJ0-4304 AJ0-4305 AJ0-7313 AJ0-8220 AJO-8311

Phenyl (Phenylhexyl) 1.�-10 AJ0-4350 AJ0-4351 AJ0-7314 AJO-7841 AJO-8303

PFP(2) (Pentafluorphenylpropyl) 1.�-8 AJO-8326 AJO-8327 — — —

SCX (SA,StrongCationExchanger) �.�-�.� AJ0-4307 AJ0-4308 AJ0-7369 — —

SAX (SB,StrongAnionExchanger) �.�-�.� AJ0-4310 AJ0-4311 AJ0-7370 — —

RP-1 (ReversedPhase-Polymer) 0-1� AJ0-5808 AJ0-5809 AJ0-7368 AJO-8358 —

Polar-RP® (Ether-linkedPhenyl) 1.�-� AJ0-6075 AJ0-6076 AJ0-7276 AJO-7845 AJO-8307

Fusion-RP (C18PolarEmbedded) 1.�-10 AJ0-7556 AJ0-7557 AJ0-7558 AJO-7844 AJO-8306

AQ C18 (PolarEndcappedC18) 1.�-�.� AJ0-7510 AJ0-7511 AJ0-7512 AJO-7843 AJO-8305

Gemini®-NX (C18TWIN™Technology) 1-1� AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371

Gemini® C18 (C18TWIN™Technology) 1-1� AJ0-7596 AJ0-7597 AJ0-7598 AJO-7846 AJO-8308

Gemini® C6-Phenyl (C6-PhenylTWIN™Technology) 1-1� AJ0-7914 AJ0-7915 — — —

Oligo-RP (C18TWIN™Technology) 1-1� AJ0-8134 AJ0-8135 AJ0-8136 AJ0-8210 AJ0-8310

Oligo-WAX (WA,WeakAnionExchanger) 1.�-11 — AJ0-8324 AJ0-8325 — —

Cartridges for Protein and Polypeptide Reversed Phase

For use with silica columns for separation of proteins & peptides, such as Jupiter® (Phenomenex); Vydac® 218TP, 214TP (Alltech Associates, Inc.); SynChropak® 300 C18, C4 (Eprogen, Inc.); Nucleosil® 300Å C18, C4; Hypersil™ 300Å, and other widepore or 300 Å brands.

Widepore C18 (ODS,Octadecyl) 1.�-10 AJ0-4320 AJ0-4321 AJ0-7224 AJO-7230 AJO-8313

Widepore C5 (Pentyl) 1.�-10 AJ0-4326 AJ0-4327 AJ0-7371 — —

Widepore C4 (Butyl) 1.�-10 AJ0-4329 AJ0-4330 AJ0-7225 AJO-7231 AJO-8314

Cartridges for Silica GFC

(Aqueous SEC) For use with silica GFC columns, such as BioSep™ (Phenomenex); Zorbax® GF-Series; Bio-Sil® (Bio-Rad).

GFC-2000 – �-�.� — AJ0-4487 AJ0-7365 — —

GFC-3000 – �-�.� — AJ0-4488 AJ0-7366 — —

GFC-4000 – �-�.� — AJ0-4489 AJ0-7367 — —

Cartridges for Carbohydrate/Organic Acid

For organic acid and carbohydrate analysis, such as Rezex™ (Phenomenex); Aminex® (Bio-Rad); Interaction; Sugar-Pak™ (Waters).

Carbo-H+ – 1.0-�.� — AJ0-4490 — — —

Carbo-Ag+* – Neutral — AJ0-4491 — — —

Carbo-Pb+2 – Neutral — AJ0-4492 — — —

Carbo-Ca+2 – Neutral — AJ0-4493 — — —

* For use with saccharide and oligosaccharide columns in Ag+ form.

Guard Cartridge Holders

$299/10pk $299/10pk $439/3pk $299/ea $325/ea

$299/10pk $299/10pk $439/3pk $299/ea $325/ea

— $299/10pk $439/3pk — —

— $299/8pk — — —

$145/kit $219/holder $305/kit $349/kit

KJ0-4282 AJ0-7220 AJ0-8223 AJ0-8277

Page 8: Is your HPLC column protected? - Phenomenexphx.phenomenex.com/lib/5721_us.pdf · Gemini®-NX (C18 TWIN™ Technology) 1 - 1 AJO-8367 AJO-8368 AJO-8369 AJO-8370 AJO-8371 Gemini

AustraliaPO Box 4084Lane Cove, NSW 2066Australia

[email protected]

mail:

tel.:fax:

email:

mail:

tel.:fax:

email:

AustriaZeppelinstr. 563741 AschaffenburgGermany

[email protected]

Canada411 Madrid Ave.Torrance, CA90501-1430USA

(800) 543-3681(310) [email protected]

IrelandQueens Avenue,Hurds�eld Ind. Est.,Maccles�eld, Cheshire SK10 2BN, UK

01 247 5405+44 [email protected]

ItalyVia Serenari, 15/D40013 Castel Maggiore (BO)Italy

051 6327511051 [email protected]

New ZealandP O Box 31-601Milford 0741North Shore CityNew Zealand

[email protected]

DenmarkGydevang 39-413450 AllerødDenmark

4824 80484810 [email protected]

FranceParc des Grillons, Bat.360 route de Sartrouville78232 Le Pecq CedexFrance

01 30 09 21 1001 30 09 21 [email protected]

GermanyZeppelinstr. 563741 AschaffenburgGermany

[email protected]

Puerto Rico273 Sierra Morena,Suite #104San Juan,Puerto Rico 00926

(800) 541-HPLC(310) [email protected]

United KingdomQueens Avenue,Hurds�eld Ind. Est.,Maccles�eld, Cheshire SK10 2BN, UK

[email protected]

USA411 Madrid Ave.Torrance, CA90501-1430USA

(310) 212-0555(310) [email protected]

www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department by telephone, fax or email: [email protected].

If you are not completely satisfied withtheperformanceofSecurityGuard,simplycontact Phenomenex within �� days andkeepSecurityGuardforFREE.

Gemini,Jupiter,Polar-RP,andLunaareregisteredtrademarksofPhenomenex,Inc.Axia,BioSep,Rezex,SecurityGuardandTWIN-

TechnologyaretrademarksofPhenomenex,Inc.AlltimaisatrademarkofAlltechAssociates,Inc.Bio-SilandAminexareregistered

trademarksofBio-RadLaboratories.Dionex isa registered trademarkofDionexCorporation.Hypersil isa trademarkofThermo

Scientific, part of ThermoFisherScientific.Nucleosil is a registered trademarkofMacherey-Nagel.Sugar-Pak is a trademark of

Waters Corporation. Symmetry is a registered trademark of Waters Corporation. SynChropak is a registered trademark of

Eprogen,Inc.VydacisaregisteredtrademarkofAlltechAssociates,Inc.ZorbaxisaregisteredtrademarkofAgilentTechnologies.

Phenomenex Inc. is in no way affiliated with the above companies. © �008 Phenomenex. All rights reserved. Subject to

PhenomenexStandardTerms&Conditions,whichmaybeviewedatwww.phenomenex.com/TermsAndConditions.

Protect your HPLC Column with SecurityGuard™

���1

_us