ISAM Unit Data Sheet
NELT-B
3FE 62543 AAAA TQZZA
Issue: 06
December 2016
NELT-B
2
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners.
The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein.
© 2016 Nokia.
Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone outside Nokia without its written authorization. Not to be used or disclosed except in accordance with applicable agreements.
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 3
1 Ethernet Line Termination Unit version B
1.1 Identification
1.2 Introduction
1.3 Features and Application Notes
1.4 General Description
1.5 Functional Blocks
1.6 External Interfaces
1.7 Physical Description
1.8 Power Supply
1.9 Installation in Subrack
1.1 Identification
Table 1 provides identification of the NELT-B:
Table 1 Unit Identification
1.2 Introduction
This document describes the Ethernet Line Termination (LT) unit version B which is used in the Intelligent Services Access Manager (ISAM).
Part Number Mnemonic Name
3FE 62543 AA NELT-B Ethernet Line Termination (LT) unit - version B
Note — See the ISAM Glossary document included in the documentation set of this release for expansion and elaboration of all acronyms and mnemonics used in this document.
Ethernet Line Termination Unit version B
4
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
1.3 Features and Application Notes
The NELT-B:
• Can be used in the following subracks:• a 7302 ISAM subrack• a 7330 ISAM Fiber To The Node (FTTN) subrack• a 7356 ISAM Fiber To The Building (FTTB) Shelf-Based Remote Expansion Module
(SB-REM).• a 7360 ISAM FX subrack
• Supports the following Small Form Pluggables (SFP):• Standard FE SFP (up to 18 channels)• Standard GE SFP (up to 18 channels)• Compact FE CSFP (2 channels per cage, up to 36 channels)• Compact GE CSFP (2 channels per cage, up to 36 channels)
• Supports downstream Synchronous Ethernet. The Network Timing Reference (NTR) is derived from the NT board.
• Can be used in the following operation conditions:• -5°C to +45°C ambient temperature range, in CO environment with multiple 7302
ISAM FD subracks and 7360 ISAM FX-16 subracks• -40°C to +65°C ambient temperature range, when used in single 7302 ISAM FD
subracks and 7360 ISAM FX-16 subracks• -40°C to +65°C ambient temperature range, when used in stand-alone 7330 ISAM
FTTN FD subracks, 7360 ISAM FX-8 subracks and 7360 ISAM FX-4 subracks• -40°C to +70°C ambient temperature range, when used in stand-alone 7356 ISAM
FTTB SB-REM (limited to 18 FE/GE per NELT-B LT)• Can be hot inserted or extracted.• Is compliant to the regulations of Reduction of Hazardous Substances (RoHS)
and Waste Electrical and Electronic Equipment (WEEE).• Is compliant to safety standards IEC / EN 60950-1 and AS/NZS 60950-1, provided
that the board is installed, maintained and used according the relevant installation instructions.
1.4 General Description
The NELT-B is a Fast Ethernet (FE)/Gigabit Ethernet (GE) line termination board which has up to 36 FE/GE optical ports for Ethernet Access.
The NELT-B meets ETSI requirements and is intended for CO and remote deployment in ISAM equipment.
The following figures show the position of the NELT-B in:
• a 7302 ISAM FD subrack (CO deployment); see Figure 1.• a 7330 ISAM FTTN FD subrack (CO or remote deployment); see Figure 2.
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 5
• a 7356 ISAM FTTB SB-REM (remote deployment); see Figure 3.• a 7360 ISAM FX subrack (FX-16, FX-12, FX-8, FX-4) see Figures 4, 5, 6 and 7.
Figure 1 Position in a 7302 ISAM FD Subrack
Figure 2 Position in a 7330 ISAM FTTN FD Subrack
Figure 3 Position in a 7356 ISAM FTTB SB-REM
LT 5
LT 6
LT 7
LT 8
LT 1
LT 2
LT 3
LT 4
LT 1
0
LT 1
1
LT 1
2
LT 1
3
NT
A
NT
IO
NT
B
LT 9
LT 1
4
LT 1
5
LT 1
6
CBs, lamps and switches
Fan unit
Connectors
LT 7
LT 6
LT 5
LT 4
LT 3
LT 2
LT 1
NT A
NT I/O
NT B
EMA-GFC
FAN
LT 8
Dummy or Splitter board
LT 2
LT 1
Controller board or NT board
FAN
Ethernet Line Termination Unit version B
6
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
Figure 4 Position in a 7360 ISAM FX-16 Subrack
Figure 5 Position in a 7360 ISAM FX-12 Subrack
LT 5
LT 6
LT 7
LT 8
LT 1
LT 2
LT 3
LT 4
LT 1
0
LT 1
1
LT 1
2
LT 1
3
NT
A
NT
IO
NT
B
LT 9
LT 1
4
LT 1
5
LT 1
6
CBs, lamps and switches
Fan unit
Connectors
NTB
NTIONTA
GFC
Fan unit
LT12
LT11
LT10
LT9
LT8
LT7
LT6
LT5
LT4
LT3
LT2
LT1
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 7
Figure 6 Position in a 7360 ISAM FX-8 Subrack
Figure 7 Position in a 7360 ISAM FX-4 Subrack
1.5 Functional Blocks
The functional blocks of the NELT-B hardware architecture are shown in Figure 8.
Figure 8 NELT-B functional Blocks
LT 7
LT 6
LT 5
LT 4
LT 3
LT 2
LT 1
NT A
NT I/O
NT B
GFC
FAN
LT 8
LT 4
LT 3
LT 2
LT 1
NT A
NT I/O
NT B
GFC
FAN
PCle
PCle
SERDES
PCIe-PCIeSwitch
IWF
Switch
Switch
9-CSFP
9-CSFP
10GE 2.5GE
2.5GE/10GE
2.5GE/10GE
2.5GE
2.5GEPCIe
18 x GE
18 x GE
18 x GE
18 x GE
PWRM-48V
Towardsbackplane
1GE/2.5GE/10GE
Ethernet Line Termination Unit version B
8
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
The NELT-B hardware architecture consists of the following functional blocks:
• The IWF block is responsible for:• the data path for the Ethernet subscriber interfaces requiring similar features as for
DSL subscriber interfaces• the control path for the Ethernet subscriber traffic• the management of the LT board.
• The switch block is for the data switch between the NT board and the subscriber lines.
• The power block provides all the power for the NELT-B board.
1.6 External Interfaces
The NELT-B has the following interfaces:
• Ethernet interfaces• SerDes interfaces• PSU interface
1.6.1 Ethernet InterfacesThe NELT-B can be configured to support the following SPFs:
• Standard FE SFP (up to 18 channels)• Standard GE SFP (up to 18 channels)• Compact FE CSFP (2 channels per cage, up to 36 channels)• Compact GE CSFP (2 channels per cage, up to 36 channels)
1.6.2 SerDes InterfacesThe NELT-B has two 10G SerDes interfaces.
The SerDes interface can auto-negotiate to 1GE, 2.5 GE and 10GE. One interface connects to NT A and the other interface connects to NT B.
Those two interfaces work in active/standby mode or in active/active (load-sharing) mode and line up with the NT status. The actual behavior depends on the NT board type, see Table 2.
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 9
Table 2 NELT-B Behavior in function of the NT Board
Each of the interfaces can be a NNI (Network-to-Network Interface), a UNI (User-to-Network Interface) or a HC-UNI (High Capacity UNI) port. See Figure 9 for the logical view of the NELT-B architecture while Table 3 lists the specifics for each of the interface types
Figure 9 NELT-B Architecture
Table 3 Interface types and their characteristics
So the backplane capacity is dependent on the NT type and the interface type, i.e f(NT, interface) and consequently, the following backplane capacity is supported by the NELT-B:
NT Board Type Behavior Description
NANT-A Active/Standby (A/S) A single NT-LT link is active
NANT-D
NANT-E
FANT-F
Active/Active (A/A) or load-sharing
Both NT-LT links are simultaneously active allowing to double the capacity
NANT-A 2 x 1G (active/standby) NANT-D 2 x 2.5G (active/active) NANT-E/FANT -F 2 x 10G (active/active)
36 FE/GE
Traffic flows : • UNI • HC-UNI (� data, … control) • NNI
Ethernet switch
IWF (2.5 Gb/s bi-dir)
UNI HC-UNI NNI
Application Low end residential
Small business
High end residential
Business
Mobile backhaul
Pre-aggregation
Large business
Traffic Management
Ethernet switch as L2 concentrator
IWF : forwarding co-processor
Ethernet switch as L2 forwarder
IWF : control plane co-processor
HW assist for high-speed packet inspection
Ethernet switch as L2 forwarder
Feature set DSL LT like DSL LT like NT like
Aggregate rate 2.5G bi-dir 2x10G bi-dir, wire speed 2x10G bi-dir, wire speed
Ethernet Line Termination Unit version B
10
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
Table 4 NELT-B Backplane Capacity
Notes(1) A restriction exists when considering UNI interfaces, i.e. for all the UNI interfaces taken together, the aggregate
capacity is limited to 2.5G by the IWF even if carried over a backplane interface with a higher rate. If the backplane is smaller (NANT-A), the rate is obviously limited to 1G.
Example with two NANT-E boards:
• For 36 NNI ports, the backplane capacity is 20G• For 36 UNI ports, the capacity for the aggregate is 2.5G (carried over a 20G
backplane)• For 36 ports mix of NNI and UNI: capacity is 20G for the NNI and HC-UNI ports
but maximum 2.5G for the UNI ports
1.6.3 PSU InterfaceThis is the Power Supply interface.
1.7 Physical Description
1.7.1 ViewFigure 10 shows the front view of the NELT-B:
UNI HC_UNI NNI
NT Board Type Simplex Duplex Simplex Duplex Simplex Duplex
NANT-A 1G 1G 1G 1G 1G 1G
NANT-D 2.5G(1) 2.5G(1) 2.5G 5G 2.5G 5G
NANT-E
FANT-F
10G 20G 10G 20G
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 11
Figure 10 Front View of the NELT-B
1.7.2 SFP SequenceFigure 11 shows the SFP sequence on the NELT-B for the possible configurations.
Ethernet Line Termination Unit version B
12
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
Figure 11 SFP Sequence
1.7.3 Dimensions:The dimensions of the NELT-B are:
• Height: 405 mm• Width: 225 mm (top) / 205 mm (bottom)• Board to board pitch: 25 mm
1.7.4 Status LEDS
POW
ER F
ILTE
R FO
R SF
P
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
FEFE
18 FE CSFP(2 channels per CSFP)
POW
ER F
ILTE
R FO
R SF
P
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
18 FE SFP(1 channel per SFP)
POW
ER F
ILTE
R FO
R SF
P
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
18 GE CSFP(2 channels per CSFP)
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
GEGE
POW
ER F
ILTE
R FO
R SF
P
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
GE
18 GE SFP(1 channel per SFP)
NELT-B Ethernet Line Termination Unit version B
Issue: 06 3FE 62543 AAAA TQZZA 13
1.7.4.1 Board LEDs on the NELT-BFigure 12 shows the board LEDS on the front of the NELT-B.
Figure 12 Board LEDS on the NELT-B
Table 5 gives the LED definitions.
Table 5 LED Definition for the NELT-B
1.7.4.2 Link LEDs on the SFPFor each SFP port, a status LED is provided on the frontpanel of the NELT-B, see Figure 13.
Figure 13 LEDS for SFP Ports
Table 6 gives the behavior of the LEDs for the SFP ports.
LED Color Description
ALM Red Alert
A/S Green Active/Standby
PWR Green On lineP
WR
ALM
A/S
1
2
3
4
5
6
7
8
StatusLED
Ethernet Line Termination Unit version B
14
NELT-B
3FE 62543 AAAA TQZZA Issue: 06
Table 6 Behavior of LEDs for SFP Ports
1.8 Power Supply
The NELT-B is compatible with -48Vdc and -60Vdc nominal power supply systems.
Note: Country dependent tolerances exist regarding the nominal battery voltage values
1.9 Installation in Subrack
Refer to the 7302 ISAM FD Hardware Installation Manual, the 7330 ISAM FTTN FD Hardware Installation Manual, the 7356 ISAM FTTB User, Safety and Installation Manual or the 7360 ISAM FX Hardware Installation Manual for a description of the mounting procedures.
Situation Status LED
Board reset Off
Link administrative down Off
Link administrative up and Loss Of signal (LOS) Off
Link administrative up and Signal detected On
Link is OK and carrying traffic Blinking
Customer document and product support
Customer documentationCustomer Documentation Welcome Page
Technical SupportCustomer Documentation Technical Support
Documentation feedbackCustomer Documentation Feedback