POWER SPACE BREAKDOWN ISKANDAR PUTERI CORE DATA CENTRE LOCATION CERTIFICATION COOLING SYSTEM TM ONE, the business solutions arm of Telekom Malaysia Berhad (TM) Group of companies is Malaysia’s leading Managed Data Centre Services provider. TM ONE leverages on TM’s domestic, regional and international Point-of-Presence (POPs) and is committed in building a carrier-neutral and green Data Centre in Iskandar Malaysia. Strategically located between Singapore and Kuala Lumpur, TM ONE Iskandar Puteri Data Centre (IPDC) is positioned to capture a slice of the regional market by offering high value managed services including cloud computing, virtualisation, workspace and collaboration services. Nusajaya Tech Park, Iskandar Malaysia, Johor Bahru Located in BCA Green Mark district 5 minutes from Malaysian Customs, Immigration and Quarantine Complex (CIQ), Tuas Second Link 15 minutes to CBD Johor Bharu 25 minutes to Senai International Airport 35 minutes to CBD Singapore 50 minutes to Changi International Airport Uptime Institute Tier III Design Uptime Institute Tier III Constructed Facility Uptime Institute Operational Sustainability* TIA-942 (Rated 3) Green Building Index (GBI) US Green Building Council LEED TVRA compliant Dual 33kV power feed from 2 separate upstream utility substations, providing up to 20mW capacity 2N configuration to protect critical IT load Able to support range of power density from 120w/sqſt up. Average about 200w/sqſt On-site standby diesel support up to 48 hour Intelligent power meter used to manage power consumption and billing Concurrently maintainable cooling system N+2 CRAC system with built-in maintainance corridor N+1 high efficiency water cooled chiller Pressurised clean data hall Integrated Building Management System & Data Centre Intrastructure Management (DCIM) 4 diverse fiber paths to external manholes 2N distribution network paths within the facility *Planned upon completion East Wing (whitespace in sq ſt) West Wing (whitespace in sqſt) Design PUE No of Phases Gross Floor Area (sq ſt) 3 30,000 60,000 1.6 350,000

Upload: others

Post on 19-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ISKANDAR PUTERI CORE DATA CENTRETM ONE leverages on TM’s domestic, regional and international Point-of-Presence (POPs) and is committed in building a carrier-neutral and green Data

POWER

SPACE BREAKDOWN

ISKANDAR PUTERI CORE DATA CENTRE

LOCATION CERTIFICATION

COOLING SYSTEM

TM ONE, the business solutions arm of Telekom Malaysia Berhad (TM) Group of companies is Malaysia’s leading Managed Data Centre Services provider. TM ONE leverages on TM’s domestic, regional and international Point-of-Presence (POPs) and is committed in building a carrier-neutral and green Data Centre in Iskandar Malaysia. Strategically located between Singapore and Kuala Lumpur, TM ONE Iskandar Puteri Data Centre (IPDC) is positioned to capture a slice of the regional market by offering high value managed services including cloud computing, virtualisation, workspace and collaboration services.

Nusajaya Tech Park, Iskandar Malaysia, Johor Bahru • Located in BCA Green Mark district• 5 minutes from Malaysian Customs, Immigration and Quarantine Complex (CIQ), Tuas Second Link• 15 minutes to CBD Johor Bharu• 25 minutes to Senai International Airport• 35 minutes to CBD Singapore• 50 minutes to Changi International Airport

• Uptime Institute Tier III Design• Uptime Institute Tier III Constructed Facility• Uptime Institute Operational Sustainability*• TIA-942 (Rated 3)• Green Building Index (GBI)• US Green Building Council LEED• TVRA compliant

• Dual 33kV power feed from 2 separate upstream utility substations, providing up to 20mW capacity• 2N configuration to protect critical IT load• Able to support range of power density from 120w/sqft up. Average about 200w/sqft• On-site standby diesel support up to 48 hour• Intelligent power meter used to manage power consumption and billing

• Concurrently maintainable cooling system• N+2 CRAC system with built-in maintainance corridor• N+1 high efficiency water cooled chiller • Pressurised clean data hall• Integrated Building Management System & Data Centre Intrastructure Management (DCIM)

• 4 diverse fiber paths to external manholes• 2N distribution network paths within the facility

*Planned upon completion

East Wing (whitespace in sq ft)

West Wing (whitespace in sqft)

Design PUE

No of Phases

Gross Floor Area (sq ft)

3

30,000

60,000

1.6

350,000

Page 2: ISKANDAR PUTERI CORE DATA CENTRETM ONE leverages on TM’s domestic, regional and international Point-of-Presence (POPs) and is committed in building a carrier-neutral and green Data

TM ONE Data Centre Locations

ISKANDAR PUTERI CORE DATA CENTRE

TELECOMMUNICATIONS

ISO/IEC 27001 : 2013ISO/IEC 20000 : 2011ISO 9000 : 2015

ITILPCI DSS

SERVICES OFFERED

OPERATION STANDARD

FIRE DETECTION &SUPPRESSION

SECURITY

Menara TM ONENo. 1, Jalan Damansara, 60000 Kuala Lumpurwww.tmone.com.my | Email : [email protected] | Tel : 603-7859 2222

The Business Solutions Arm of Telekom Malaysia Berhad (TM) Group

• 24x7 security officers• Integrated security management system• Equipped with mail, parcel and baggage X-ray scanner• Anti-passback man traps and biometric (2 factor authentication) access control• Fence intrusion detection system with perimeter surveillance integration• K4 rated retractable bollards• 9 levels of physical security pass required before gaining access to hosted computer and equipment

• 4 diverse fiber paths to external manholes• 2N distribution network paths within the facility• Telekom Malaysia Iskandar International Gateway (IIGW)• Carrier-neutral data centre with rich telco ecosystem

• Fire and smoke detection sensors above and below raised floor• NOVEC-1230 primary file suppression system• Dry pipe pre-actioned system as secondary building protection• Early sensitive smoke detection system

• Co-Location/Hosting Dedicated/Cage/Wholesale)• Cloud Services• Backup and Recovery Services• Disaster Recovery Workspace Services• Meeting Rooms• Business Suites• Network Cross Connect Services• Smart Hand Services

• 15KN/m floor loading• 6.0m height slab to slab, 1.0m raised floor