iso 14001 certified - e-power ccl co.,ltd · trafo union gmbh (germany), a ... remarks: the acronym...
TRANSCRIPT
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Company Introduction Thai Maxwell Electric Company Limited (TME) is a leading manufacturer of distribution and instrument transformers, and other synergistic industrial products in Thailand. Established in 1979 and promoted by the Board of Investment (BOI), Royal Thai Government since 1980, we are part of the Maxwell Group, a niche industrial group (consisting of 17 companies employing over 1,200 personnel) that caters to the infrastructure development of both the private and public sector. Maxwell Group has numerous business interests ranging from power line insulators and power generators to warehouse racking systems and environmental control equipment to industrial, construction and electrical engineering services. TME’s joint venture with Aichi Electric Co., Ltd. in 1987, one of Japan’s largest electric power product manufacturers, strengthens our technological expertise through close technical and management collaboration. Our culture of innovation has seen no less than 8 technical partnerships with global industry experts and the continuous strengthening of our in-house product development capability. This is evidenced by the many pioneering technological advances that we have introduced to the Thai market. TME has 2 business lines – electric power products and pneumatic products. Electric power products is our primary business line, which incorporates the designing, manufacturing and servicing of distribution transformers, instrument transformers and load break switches (LBS). The pneumatic product line incorporates the designing, manufacturing and servicing of air compressors and complementary equipment. TME products are manufactured under stringent manufacturing and quality management systems (ISO 9001 and 14001) which conform to international standards (ANSI/IEEE, DIN/VDE, IEC, BS, JIS and TIS) and have an outstanding track record and reputation for high product quality and reliability. TME has its own after-sales service teams as well as appointed authorized after-sales service teams strategically located throughout Thailand. All service technicians are professionally trained and equipped with the latest equipment to ensure that our client’s equipment are maintained in optimum working condition.
TME’s corporate slogan, “Thai Maxwell. There for you!” reflects our entire company’s commitment to building long-lasting, value-creating partnerships with our clients and other “stakeholders”. We strive to provide our clients with the latest technologically advanced equipments to utilise their resources efficiently and effectively whilst also helping to conserve earth’s resources and protect our fragile environment. A testament to our success is our large and ever increasing number of satisfied clients ranging from State-owned agencies to MNCs and SMEs who have placed their trust in our products and services.
1
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME is committed to developing innovative and environmentally friendly products and services for the advancement of Thailand’s industrial sector. “Thai Maxwell. There for you!”
TME Company Slogan “THAI MAXWELL. THERE FOR YOU”
TME Company Vision “To deliver attractive growth by providing imaginative, competitive and quality medium voltage electrical products and services and be recognized as one of the leading medium voltage electrical solutions provider in Asean by 2012”
TME Company Mission Statement
- Use innovation to develop products and services with maximum competitiveness
- To continuously improve product and service quality through innovative
ideas and sincere actions - To create “win-win” partnerships with our “stakeholders” to ensure long-
term success - To provide our staff with a better quality of life through continuous
upgrading of their knowledge, skills, competency and working conditions
- To be a responsible corporate citizen, contributing to the well-being of
our environment and society - To create highly satisfied and loyal “stakeholders” through “the TME
experience”
2
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Company Data
Year of establishment : 1979 Authorized capital : 144,000,000 Baht (Paid-up) Shareholders : Thai 68% Foreign 32% Name of executive officers : YONG Yuan Sun, Managing Director Number of employees : 280 Land and building area : Land 27,000 m2 Building (Factory) 20,000 m2 Transformer production capacity : 1,000,000 kVA per year or 1,000 units of 1,000 kVA transformers per year Bank references : Siam Commercial Bank PCL (Omyai Branch) Bangkok Bank PCL (Silom Head Office) Kasikorn Bank PCL (Sampran Branch) Association references : Nakornpathom Chamber Of Commerce The Federation Of Thai Industries, Nakornpathom Chapter Electrical and Electronics Institute Personnel Management Association Of Thailand Personnel Management Association Of Nakornpathom Safety Officer Association Of Nakornpathom Thai Electrical & Mechanical Contractors Association Singapore-Thai Chamber of Commerce
3
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
Contact details – Head Office and Factory : Address - 32/7 Moo 1 Soi Watthiandad, Petchkasem Road, Banmai, Sampran, Nakornpathom 73110 Thailand Telephone - +66 (0) 2429 0033 Facsimile - +66 (0) 2429 0194 E-mail - [email protected] Website - www.thaimaxwell.co.th
www.tme.bz
Coordinates - N13 42.243’ E100 14.858’ or N13 42’ 14.6” E100 14’ 51.5”
Contact details – Surat Thani Branch : Address - 16/6 Moo 3 Bypass Road, Makhamtia, Muang,
Surat Thani 84000 Thailand Telephone - +66 (0) 7740 5856 Facsimile - +66 (0) 7743 7268 E-mail - [email protected]
Coordinates - N09 06.133’ E099 19.013’ Contact details – Had Yai Branch : Address - 28 Po. Nathapon 3 Road, Had Yai, Songkla 90110
Thailand Telephone - +66 (0) 7442 9503 Facsimile - +66 (0) 7424 3299 E-mail - [email protected]
Coordinates - N06 59.830’ E100 28.521’
4
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Company Product Range Electric Power System:
“THAI MAXWELL” Distribution Transformers (Oil-immersed/Dry type)
- Oil-immersed hermetically sealed transformer - Oil-immersed conservator tank transformer - Oil-immersed completely self protected (CSP) transformer - Unit sub-station transformer - Cast resin dry-type transformer - Ventilated dry-type (VDT) transformer - Conventional dry-type (CDT)transformer
(see back to find attached technical data sheet for further details) “THAI MAXWELL” Instrument Transformers (Oil-immersed/Dry type)
- Cast resin current transformer (outdoor) - Cast resin current transformer (indoor) - Cast resin voltage transformer (outdoor) - Cast resin voltage transformer (indoor) - Oil-immersed current transformer (outdoor) - Oil-immersed voltage transformer (outdoor) - Cast resin ring type transformer (outdoor) - Plastic ring type transformer (indoor)
(see back to find attached technical data sheet for further details) “THAI MAXWELL” SF6 Gas Load Break Switch (LBS) “MAXWELL” Switchboard System “MAXWELL” Cable Tray System Pneumatic System: “MAXWELL” Air Compressor and complementary equipment
- Single stage piston-type air compressors - Two stage piston-type air compressors - Screw-type air compressors - Air dryers - Air tanks - Air filters
5
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Technical Collaboration Timeline
1982
1987
1992
1996
2002
1985
2003 E.I. Du Pont (USA) for use of “Nomex” in ventilated dry-type transformers (VDT)
Shin Sung Industrial Electric Co., Ltd. (S.Korea) for SF6 gas load break switch(LBS)
KWK Messwandler GmbH & Co.Kg. (Germany) for cast resin medium voltage instrument transformer
Iwatec GmbH (Switzerland) for uninterruptible power supply (UPS) systems
Aichi Electric Co., Ltd. (Japan) for 1 phase open type wound core distribution transformers
G.I. International Co., Ltd. (United Kingdom) for “Halocool” non - flammable type transformers
Trafo Union GmbH (Germany), a subsidiary of Siemens Ltd. for assembly of “GEAFOL” cast resin transformers
IEO Transformatoren B.V. (Netherlands) for 3 phase stacking core distribution transformers
1979 Maxwell Taiwan Co., Ltd. (Taiwan) for 1 phase and 3 phase closed type wound core distribution transformers
6
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Technical Achievements Timeline
1982
1987
1992
1996
1984
1985
2003
1979
1988
1989
1998
1995
2006
Started production of closed type wound core (FIT for 3 phase type) distribution transformers
Assembly of dry-type cast resin transformers (FIT)
Started production of conventional dry-type transformers
Started production of Japanese technology open type wound core transformers
Developed SF6 gas insulated transformer
Started production of completely self-protected (CSP) transformers
Started production of transformers with on load tap changers (OLTC) (FIT for medium voltage)
Developed transformers with “Amorphous” core (FIT)
Started production of oil-immersed instrument transformers
Started production of hermitically sealed transformers
Started production of cast-resin instrument transformers (FIT for sales to MEA)
Started production of cast resin ring type instrument transformers
Started production of ventilated dry-type (VDT) transformers with DuPont “Nomex” paper (FIT)
Started production of dry-type cast resin transformers
Started production of piston-type air compressors
Started production of material handling equipment
Started production of UPS systems
Started production of Load Break Switches
Started production of “Halocool” non-flammable type transformers (FIT)
Remarks: The acronym FIT (First In Thailand) means that the technical achievement was first achieved in Thailand by TME.
2002 In-house partial discharge type test for instrument transformers (FIT)
In-house short circuit type test for distribution transformers (FIT)
Started production of corrugated tank transformers (FIT)
7
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Quality Achievements Timeline
1996
2000
2006
1998
1999
1983
2005
Remarks: The acronym FIT (First In Thailand) means that the quality achievement was first achieved in Thailand by TME.
Quality standard TIS 384-2525 by Thai Industrial Standard Institute (TISI) for distribution transformers
Quality system standard ISO 9001:1994 by BVQI for distribution transformers (FIT)
Quality standard TIS 1252-2537 by Thai Industrial Standard Institute (TISI) for piston-type air compressors
Type test by Kema High-Power Laboratory for distribution transformers
Quality standard ISO 9001:1994 for air compressor and instrument transformer
Type test by Powertech Labs Inc. for cast resin current transformers
Type test by Kema High-Voltage Laboratory for cast resin instrument transformers
Quality standard ISO 9001:2000 for high voltage switch gears and control gears
Type test by CESI S.p.A. for load break switch
Quality standard ISO 14001:2004 for transformers; switch and control gears
8
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
TME Affiliated Companies Thai Maxwell Electric Company Limited is the parent company of the Maxwell Group, which has combined annual revenues of Baht 2.5 billion, employing some 1,200 personnel. It includes the following companies:
- Thai Maxwell Industrial Service Co., Ltd.(provider of petrol chemical or
industrial equipment / plant maintenance and repair services; industrial oil and waste treatment services; distributor and rental of high pressure water jet blaster and oil sludge treatment equipment; and provider of industrial incinerator design, consultation and installation services)
- Thai Maxwell Fabricate Co., Ltd. (provider of metal fabrication work) - Thai Maxwell Coating Co., Ltd. (provider of production line spray
painting and powder coating services) - T.M. Industry Co., Ltd. (manufacturer of main distribution board, control
switch cabinet and wire tray systems; material handling equipment; and distributor of storage/warehouse racking systems, conveyor systems and rollers)
- Storage System Industry Co., Ltd. (manufacturer of storage/warehouse racking systems, conveyor systems and rollers)
- Piller (Thailand) Co., Ltd. (manufacturer of power generators, static / dynamic UPS systems, stabilizers, frequency converters and capacitors)
- Elmax Co., Ltd. (provider of power / control LV & HV system design, consultation, installation and maintenance services)
- Modern Ceramic Co., Ltd. (manufacturer of HV & LV porcelain electrical insulators)
- Rayong Ceramic Manufacturing Co., Ltd. (manufacturer of ceramic transformer insulator bushings)
- Maxwell Service Center Co., Ltd. (provider of transformer repair and maintenance services)
- Maxwell Construction Co., Ltd. (provider of industrial construction, civil engineering services and construction supplies)
- Maxwell Tunneling Co., Ltd. (provider of tunneling services, rental and maintenance of tunneling equipment)
- Maxklen Co., Ltd. (distributor of industrial/commercial cleaning and environmental pollution control (dust, fume, material extraction) equipment; manufacturer of industrial / commercial cleaning chemicals)
- Interlink Wire & Cable Co., Ltd. (manufacturer of industrial/electrical wires and cables)
- Maxwell Balance Co., Ltd. (spray booth, auto body collision repair systems, tools & accessory for auto body)
- Sunshine Aviation Co., Ltd. (authorized distributor and service center of “Jabiru” light sport aircraft from Australia)
The principal shareholders of the Maxwell Group are associated with:
- Meng Seng Group of Companies (manufacturer of confectionary and glucose based raw materials)
- Thai Preserved Food Co., Ltd. (manufacturer of “Wai Wai” instant noodles)
9
A member of Thai Maxwell Group
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
a member of Maxwell Group
- Bangkok Starch Industrial Co., Ltd. (manufacturer of starch based raw
materials) - Thai Paper Mill Co., Ltd. (manufacturer of carton boxes) - Aichi Electric (Japan) Co., Ltd. (manufacturer of electrical distribution
transformers)
TME Client references
Satisfied clients of Thai Maxwell Electric Company Limited, range from State-owned agencies to MNCs and SMEs (numbering over 9,000 clients) as seen from the following partial client list:
Government Sector
Industrial Sector
Asahi Thai Alloy Co.,Ltd. B.Grimm Engineering System Plc BP Oil (Thailand) Co.,Ltd. Bayer Thai Co.,Ltd. Betagro Agro Group Plc
Quality standard TIS 384-2525 by Thai
Industrial Standard Institute (TISI) for
distribution transformers
Airports Authority Of Thailand Electricity Generating Authority Of Thailand (EGAT) Embassy Of The United States Of America Metropolitan Electricity Authority (MEA) Metropolitan Water Works Authority Ministry Of Education Ministry Of Energy
Provincial Electricity Authority (PEA) Petrochemical Authority Of Thailand Port Authority Of Thailand Royal Thai Airforce Royal Thai Navy State Railway Of Thailand
ABB Distribution Ltd. Alcan Packaging Strongpack Plc Amata (Thailand) Co.,Ltd. Ajinomoto (Thailand) Co.,Ltd. Ajinomoto Betagro Frozen Foods (Thailand) Co.,Ltd.
10
A member of Thai Maxwell Group
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
a member of Maxwell Group
Industrial Sector (continued)
Caltex Oil (Thai) Co.,Ltd. Colgate-Palmolive (Thailand) Co.,Ltd. Delta Electronic Co.,Ltd. Esso (Thailand) Plc Green Spot (Thailand) Co.,Ltd. Hanami Foods Co.,Ltd. Hino Motors (Thailand) Co.,Ltd. Hitachi Consumer Products (Thailand) Co.,Ltd. Hitachi Bangkok Cable Co.,Ltd. Honda Cars (Thailand) Co.,Ltd.
Hyundai Engineering
Construction Co.,Ltd.
Italian Thai Development Plc Matsushita Battery (Thailand) Co.,Ltd. Meinhardt-Atc (Thailand) Co.,Ltd. Mitsubishi Electrical Automation Co.,Ltd.
Nanyang Textile Co.,Ltd. PTT Plc Royal Porcelain Plc Samsung Electro-Mechanics (Thailand) Co.,Ltd. Sanyo Universal Electric Plc Singer Thailand Plc Sino-Thai Construction Service Co.,Ltd. Siemens Co.,Ltd. Tatung (Thailand) Co.,Ltd. Thai Glico Co.,Ltd. Thai Toshiba Lighting Co.,Ltd. Thai Yamaha Motor Co.,Ltd. Tipco Foods (Thailand) Plc Toa Paint (Thailand) Co.,Ltd. Toshiba Carrier (Thailand) Co.,Ltd.
Asahi Plastic Co.,Ltd. Asahi Tec Aluminium (Thailand) Co.,Ltd.
Boonrawd Brewery Co.,Ltd. Cal-Comp Electronic (Thailand) Co.,Ltd.
11
A member of Thai Maxwell Group
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
a member of Maxwell Group
Industrial Sector (continued)
Commercial Sector
Export Sector
Thai Maxwell Electric Company Limited products have been distributed to Australia, Bangladesh, Japan, Laos, Malaysia, Myanmar, Philippines, Sri Lanka, UAE, USA, Nepal, Cuba, Taiwan, Uganda, Suriname and Vietnam. The following foreign electrical authorities have purchased our products:
Tyco International (Thailand) Co.,Ltd.
Yausa Battery Thailand Plc
Advance Info Service Plc Bangkok Bank Plc Cat Telecom Plc C.P. Seven Eleven Plc Kasikorn Bank Plc
Siam Makro Plc
Telecomasia Corporation Plc Thai Airways Plc The Mall Group Co.,Ltd. Total Access Communication Plc TOT Plc
Electricite Du Laos - Laos Sabah Electricity Board - Malaysia
Dubai Electricity & Water Authority - UAE
Mitsubishi Electric Thai Auto-Parts Co.,Ltd.
Toyota Tsusho (Thailand) Co.,Ltd.
Mitsubishi Heavy Industries (Thailand) Ltd.
Tripetch Isuzu Service Co., Ltd.
12
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
Kema High-Power Laboratory Short-circuit Performance Type Test 250kVA 24kV IEC60076-5 Certificate No. 87-98 dated
30 Nov 1998
Kema High-Power Laboratory Short-circuit Performance Type Test 250kVA 12/24kV IEC60076-5 Certificate No. 86-98 dated 30
Nov 1998
TME Certification List Attached herein are the certificates attesting to Thai Maxwell Electric’s conformance to relevant quality management systems, industry standards and other government regulation requirements:
Global Certification Service Limited ISO 9001:2008 Certificate No. QMS46011
dated 17 Aug 2009
Global Certification Service Limited ISO 14001:2004 Certificate No. EMS49003 dated 1 Aug 2009
Kema High-Power Laboratory Short-circuit Performance Type Test
1000kVA 12/24kV IEC60076-5 Certificate No.85-98 dated 30 Nov 1998
URS ISO 9001:2000 Certificate No. 3286 dated 1 May 2007
13
ISO 19001 CERTIFIED ISO 14001 CERTIFIED
Kema High-Voltage Laboratory Complete Type TestCurrent Transformer 25.5kV 60Hz
IEEE STD.C57.13 (1993) Certificate No. 00-1088 dated 21 Jul 2000
Kema High-Voltage Laboratory Complete Type TestVoltage Transformer 24kV 60Hz
IEEE STD.C57.13(1993) Certificate No. 00-1089 dated 21 Jul 2000
Powertech Labs Inc Current Transformer Accuracy TestCurrent Transformer (Cast Resin) 25.5kV 60Hz IEEE C57.13(1993)
Report No. 11737-23(A3) dated 21 May 1999
Powertech Labs Inc Current Transformer Short Time TestCurrent Transformer (Cast
Resin) 25.5kV 60Hz IEEE C57.13(1993) Report No. 11737-23(B5) dated 21 May 1999
Centro Elettrotecnico Sperimentale Italiano Complete Type Test LBS 33kV 400A IEC60265-1(1998) Certificate No.
A5/005329dated 16 Feb 2005
Centro Elettrotecnico Sperimentale Italiano Complete Type Test LBS 24kV 630A IEC60265-1(1998) Certificate No.
A5/005724dated 16 Feb 2005
14
Rated primary voltage : 24kV, 22kV, 12kV, 6.6kV or below
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 160 950 1110 4.0 98.43 97.83 1.96 48 710 920 890 85 335
100 250 1550 1800 4.0 98.74 98.23 1.62 51 705 1085 930 95 500
160 360 2100 2460 4.0 98.91 98.49 1.38 55 755 1270 1000 145 720
250 500 2950 3450 4.0 99.02 98.64 1.25 55 800 1030 1130 235 1090
315 800 3900 4700 4.0 98.89 98.53 1.31 56 935 1465 1040 195 1060
400 960 4600 5560 4.0 98.96 98.63 1.22 56 990 1500 1130 280 1260
500 1150 5500 6650 4.0 99.00 98.69 1.17 56 980 1565 1330 425 1680
630 1350 6500 7850 4.0 99.06 98.77 1.11 57 940 1560 1590 430 1955
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1230 1875 1670 555 2360
800 1400 10500 11900 6.0 99.00 98.53 1.48 58 1230 1840 1700 580 2350
1000 1600 12500 14100 6.0 99.06 98.61 1.42 58 1270 2100 1545 765 2900
1250 1850 14500 16350 6.0 99.13 98.71 1.33 60 1300 2150 1730 780 3270
1500 2050 18000 20050 6.0 99.13 98.68 1.37 60 1285 2110 1920 890 3825
1600 2350 19000 21350 6.0 99.12 98.68 1.36 61 1360 2200 1850 1065 4430
2000 2650 22500 25150 6.0 99.18 98.76 1.30 61 1390 2320 1920 1220 5115
2500 3000 25500 28500 7.0 99.26 98.87 1.26 62 1420 3320 2150 1250 5570
3000 3800 33000 36800 7.0 99.20 98.79 1.34 63 1450 2400 2150 1430 6600
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOH-0109
TECHNICAL DATA OF OIL-IMMERSED HERMETICALLY SEALED THREE PHASE TRANSFORMER
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
15
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 170 950 1120 4.0 98.40 97.81 1.96 48 270 920 1040 108 395
100 260 1550 1810 4.0 98.72 98.22 1.62 51 770 1260 1120 155 615
160 370 2100 2470 4.0 98.89 98.48 1.38 55 700 1220 1250 210 900
250 520 2950 3470 4.0 99.00 98.63 1.25 55 770 1280 1270 250 1165
315 850 3900 4750 4.0 98.85 98.51 1.31 56 1000 1420 1275 275 1135
400 1000 4600 5600 4.0 98.94 98.62 1.22 56 1010 1490 1405 340 1475
500 1200 5500 6700 4.0 98.98 98.68 1.17 56 910 1540 1630 405 1735
630 1400 6500 7900 4.0 99.05 98.76 1.11 57 920 1550 1740 460 2030
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1080 1780 1740 545 2265
800 1450 10500 11950 6.0 98.99 98.53 1.48 58 1340 1860 1705 665 2550
1000 1650 12500 14150 6.0 99.05 98.60 1.42 58 1270 2090 1810 705 2890
1250 1900 14500 16400 6.0 99.12 98.70 1.33 60 1290 2130 1940 830 3420
1500 2100 18000 20100 6.0 99.13 98.68 1.37 60 1310 2165 2065 1040 4475
1600 2400 19000 21400 6.0 99.11 98.68 1.36 61 1330 2170 2140 1135 4700
2000 2700 22500 25200 6.0 99.17 98.76 1.30 61 1370 2280 2100 1235 5020
2500 3150 25500 28650 7.0 99.24 98.87 1.26 62 1440 2350 2140 1250 5450
3000 3900 33000 36900 7.0 99.20 98.78 1.34 63 1450 2400 2160 1440 6490
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOH-0209
TECHNICAL DATA OF OIL-IMMERSED HERMETICALLY SEALED THREE PHASE TRANSFORMER
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
16
Rated primary voltage : 24kV, 22kV, 12kV, 6.6kV or below
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 160 950 1110 4.0 98.43 97.83 1.96 48 740 1200 970 90 330
100 325 1750 2075 4.0 98.50 97.97 1.81 51 770 1230 1040 110 510
160 480 2350 2830 4.0 98.68 98.26 1.54 55 880 1400 1100 160 740
250 670 3250 3920 4.0 98.83 98.46 1.37 55 900 1410 1220 220 1050
315 800 3900 4700 4.0 98.89 98.53 1.31 56 800 1550 1600 320 1260
400 720 4150 4870 4.0 99.13 98.80 1.11 56 850 1610 1620 340 1390
500 860 4950 5810 4.0 99.17 98.85 1.07 56 980 1690 1700 420 1680
630 1350 6500 7850 4.0 99.06 98.77 1.11 57 1020 1740 1770 470 1970
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1220 1920 1830 600 2370
800 1450 9900 11350 6.0 99.03 98.60 1.41 58 1230 1940 1940 620 2380
1000 1600 12500 14100 6.0 99.06 98.61 1.42 58 1270 2050 1960 730 2880
1250 1850 14500 16350 6.0 99.13 98.71 1.33 60 1280 2130 1970 810 3480
1500 2050 18000 20050 6.0 99.13 98.68 1.37 60 1290 2140 2110 960 3840
1600 2350 19000 21350 6.0 99.12 98.68 1.36 61 1340 2140 2180 1070 4330
2000 2650 22500 25150 6.0 99.18 98.76 1.30 61 1400 2330 2190 12320 5180
2500 3000 25500 28500 7.0 99.26 98.87 1.26 62 1550 2580 2380 1660 6690
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOC-0309
TECHNICAL DATA OF OIL-IMMERSED CONSERVATOR TANK THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
17
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 170 950 1120 4.0 98.40 97.81 1.96 48 820 1520 1110 110 390
100 260 1550 1810 4.0 98.72 98.22 1.62 51 840 1730 1230 170 620
160 370 2100 2470 4.0 98.89 98.48 1.38 55 840 1660 1310 200 810
250 520 2950 3470 4.0 99.00 98.63 1.25 55 960 1630 1370 270 1180
315 850 3900 4750 4.0 98.85 98.51 1.31 56 810 1570 1650 320 1280
400 1000 4600 5600 4.0 98.94 98.62 1.22 56 870 1650 1680 350 1440
500 1200 5500 6700 4.0 98.98 98.68 1.17 56 1000 1720 1750 420 1740
630 1400 6500 7900 4.0 99.05 98.76 1.11 57 1190 1800 1820 480 2050
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1250 1900 1850 610 2450
800 1450 10500 11950 6.0 98.99 98.53 1.48 58 1250 1970 1970 640 2480
1000 1650 12500 14150 6.0 99.05 98.60 1.42 58 1270 2100 2000 750 2950
1250 1900 14500 16400 6.0 99.12 98.70 1.33 60 1290 2150 2150 820 3500
1500 2100 18000 20100 6.0 99.13 98.68 1.37 60 1310 2170 2200 970 3900
1600 2400 19000 21400 6.0 99.11 98.68 1.36 61 1350 2170 2220 1080 4350
2000 2700 22500 25200 6.0 99.17 98.76 1.30 61 1410 2420 2250 1330 5450
2500 3150 25500 28650 7.0 99.24 98.87 1.26 62 1600 2620 2400 1760 7020
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOC-0409
TECHNICAL DATA OF OIL-IMMERSED CONSERVATOR TANK THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
18
Rated primary voltage : 24kV, 22kV, 12kV, 6.6kV or below
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
315 800 3900 4700 4.0 98.89 98.53 1.31 56 890 1850 1680 480 1610
400 960 4600 5560 4.0 98.96 98.63 1.22 56 940 1940 1720 510 1810
500 1150 5500 6650 4.0 99.00 98.69 1.17 56 1000 1950 1770 580 2080
630 1350 6500 7850 4.0 99.06 98.77 1.11 57 1130 2000 2010 630 2300
750 1380 9000 10380 6.0 99.04 98.63 1.37 57 1170 2190 1910 700 2450
800 1400 10500 11900 6.0 99.00 98.53 1.48 58 1200 2280 1900 820 2890
1000 1600 12500 14100 6.0 99.06 98.61 1.42 58 1260 2160 1950 770 3080
1250 1850 14500 16350 6.0 99.13 98.71 1.33 60 1450 2390 2020 960 3900
1500 1840 19800 21640 6.0 99.10 98.58 1.49 60 1460 2320 2250 1180 4690
1600 2000 20500 22500 6.0 99.12 98.61 1.45 61 1500 2480 2120 1260 4930
2000 2650 22500 25150 6.0 99.18 98.76 1.30 61 1520 2540 2460 1470 5970
2500 3000 25500 28500 7.0 99.26 98.87 1.26 62 1600 2750 2650 2130 7800
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Yyn 0
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOA-0509
TECHNICAL DATA OF OIL-IMMERSED AUTOMATIC VOLTAGE REGULATING THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
19
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
315 850 3900 4750 4.0 98.85 98.51 1.31 56 940 1920 1700 520 1660
400 1000 4600 5600 4.0 98.94 98.62 1.22 56 990 2020 1750 550 1860
500 1200 5500 6700 4.0 98.98 98.68 1.17 56 1050 2020 1800 620 2140
630 1400 6500 7900 4.0 99.05 98.76 1.11 57 1190 2080 2030 680 2370
750 1450 9000 10450 6.0 99.02 98.63 1.37 57 1230 2280 2040 750 2520
800 1450 10500 11950 6.0 98.99 98.53 1.48 58 1260 2370 2000 880 2980
1000 1650 12500 14150 6.0 99.05 98.60 1.42 58 1320 2290 1990 900 3170
1250 1900 14500 16400 6.0 99.12 98.70 1.33 60 1520 2490 2100 1020 4020
1500 2100 19800 21900 6.0 99.07 98.56 1.49 60 1530 2410 2300 1260 4830
1600 2400 20500 22900 6.0 99.07 98.59 1.45 61 1570 2580 2160 1350 5080
2000 2700 22500 25200 6.0 99.17 98.76 1.30 61 1600 2630 2510 1570 6150
2500 3150 25500 28650 7.0 99.24 98.87 1.26 62 1680 2800 2670 2250 7940
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Yyn 0
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOA-0609
TECHNICAL DATA OF OIL-IMMERSED AUTOMATIC VOLTAGE REGULATING THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
20
Rated primary voltage : 24kV, 22kV, 12kV, 6.6kV or below
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1270 1680 1700 510 2220
800 1400 10500 11900 6.0 99.00 98.53 1.48 58 1280 1700 1720 520 2270
1000 1600 12500 14100 6.0 99.06 98.61 1.42 58 1480 2200 2020 810 3350
1250 1850 14500 16350 6.0 99.13 98.71 1.33 60 1500 2250 1970 870 3480
1500 2050 18000 20050 6.0 99.13 98.68 1.37 60 1540 2230 2200 950 4030
1600 2350 19000 21350 6.0 99.12 98.68 1.36 61 1690 2390 2170 990 4310
2000 2650 22500 25150 6.0 99.18 98.76 1.30 61 1760 2550 2200 1330 5530
2500 3000 25500 28500 7.0 99.26 98.87 1.26 62 1780 2690 2370 1650 6680
3000 3800 33000 36800 7.0 99.20 98.79 1.34 63 1800 2730 2600 1910 7860
3500 4000 35500 39500 7.0 99.27 98.88 1.25 64 2010 2970 2540 2090 8830
4000 4200 40000 44200 7.0 99.30 98.91 1.24 64 2050 3110 2830 2500 9550
5000 6000 45000 51000 7.0 99.31 98.99 1.14 65 2070 3140 2900 2650 10850
6000 7500 55000 62500 7.0 99.30 98.97 1.16 66 2180 3300 3080 3600 14500
8000 9400 59000 68400 8.0 99.40 99.15 1.05 68 2250 3600 3280 4200 18000
10000 11000 63000 74000 8.0 99.47 99.27 0.95 68 2780 4250 3480 5200 23000
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOC-0709
TECHNICAL DATA OF OIL-IMMERSED CONSERVATOR TANK THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
21
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1290 1700 1710 530 2250
800 1450 10500 11950 6.0 98.99 98.53 1.48 58 1410 2160 1930 6600 2665
1000 1650 12500 14150 6.0 99.05 98.60 1.42 58 1460 2150 2010 794 3301
1250 1900 14500 16400 6.0 99.12 98.70 1.33 60 1500 2250 2070 840 3550
1500 2100 18000 20100 6.0 99.13 98.68 1.37 60 1510 2370 2140 1100 4560
1600 2400 19000 21400 6.0 99.11 98.68 1.36 61 1700 2410 2200 1120 4590
2000 2700 22500 25200 6.0 99.17 98.76 1.30 61 1720 2640 2350 1360 5400
2500 3150 25500 28650 7.0 99.24 98.87 1.26 62 1710 2980 2290 2130 7650
3000 3900 33000 36900 7.0 99.20 98.78 1.34 63 2000 3000 2640 2070 8535
3500 5000 35500 40500 7.0 99.21 98.86 1.25 64 2050 3010 2940 2110 8850
4000 5500 40000 45500 7.0 99.23 98.88 1.24 64 2100 3150 2850 2550 9600
5000 6500 45000 51500 7.0 99.30 98.98 1.14 65 2120 3190 2950 2700 10900
6000 8000 55000 63000 7.0 99.28 98.96 1.16 66 2230 3350 3130 3650 14550
8000 9900 59000 68900 8.0 99.39 99.15 1.05 68 2300 3650 3330 4250 18050
10000 11500 63000 74500 8.0 99.46 99.26 0.95 68 2830 4300 3530 5250 23050
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOC-0809
TECHNICAL DATA OF OIL-IMMERSED CONSERVATOR TANK THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
22
Rated primary voltage : 24kV, 22kV, 12kV, 6.6kV or below
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
315 800 3900 4700 4.0 98.89 98.53 1.31 56 880 1890 1720 520 1650
400 960 4600 5560 4.0 98.96 98.63 1.22 56 970 2020 1810 550 1840
500 1150 5500 6650 4.0 99.00 98.69 1.17 56 1130 2100 1970 670 2280
630 1350 6500 7850 4.0 99.06 98.77 1.11 57 1230 2100 1960 700 2700
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1250 2180 1890 750 2810
800 140 10500 10640 6.0 99.31 98.69 1.48 58 1280 2280 1910 840 2900
1000 1600 12500 14100 6.0 99.06 98.61 1.42 58 1470 2160 1960 780 3080
1250 1850 14500 16350 6.0 99.13 98.71 1.33 60 1520 2370 2030 980 3920
1500 2050 18000 20050 6.0 99.13 98.68 1.37 60 1520 2300 2200 1130 4630
1600 2350 19000 21350 6.0 99.12 98.68 1.36 61 1640 2460 2070 1210 4880
2000 2650 22500 25150 6.0 99.18 98.76 1.30 61 1700 2520 2310 1350 5800
2500 3000 25500 28500 7.0 99.26 98.87 1.26 62 1980 2740 2380 1790 7410
3000 3800 33000 36800 7.0 99.20 98.79 1.34 63 2010 2860 2390 1930 8220
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Yyn 0
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOA-0909
TECHNICAL DATA OF OIL-IMMERSED AUTOMATIC VOLTAGE REGULATING THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
23
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
315 850 3900 4750 4.0 98.85 98.51 1.31 56 920 1990 1760 550 1750
400 1000 4600 5600 4.0 98.94 98.62 1.22 56 1020 2100 1850 590 1950
500 1200 5500 6700 4.0 98.98 98.68 1.17 56 1190 2180 2010 710 2420
630 1400 6500 7900 4.0 99.05 98.76 1.11 57 1290 2200 2000 740 2860
750 1450 9000 10450 6.0 99.02 98.63 1.37 58 1310 2270 1930 800 2920
800 1450 10500 11950 6.0 98.99 98.53 1.48 58 1340 2390 1950 890 3010
1000 1650 12500 14150 6.0 99.05 98.60 1.42 58 1540 2290 1960 870 3200
1250 1900 14500 16400 6.0 99.12 98.70 1.33 60 1600 2460 2070 1040 4030
1500 2100 18000 20100 6.0 99.13 98.68 1.37 60 1610 2400 2250 1200 4810
1600 2400 19000 21400 6.0 99.11 98.68 1.36 61 1720 2580 2150 1280 5080
2000 2700 22500 25200 6.0 99.17 98.76 1.30 61 1790 2620 2300 1430 6000
2500 3150 25500 28650 7.0 99.24 98.87 1.26 62 1710 3050 2290 2130 7650
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 60 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Connection symbol : Yyn 0
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOA-1009
TECHNICAL DATA OF OIL-IMMERSED AUTOMATIC VOLTAGE REGULATING THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
24
Rated primary voltage : 22kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
30 120 430 550 2.0 98.51 98.20 1.44 48 625 520 1000 48 220
50 150 670 820 2.2 98.75 98.39 1.36 51 700 570 1150 118 305
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 55 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Polarity : Subtractive
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOH-1109
TECHNICAL DATA OF OIL-IMMERSED HERMETICALLY SEALED SINGLE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
25
Rated primary voltage : 19kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
30 120 430 550 2.0 98.51 98.20 1.44 48 625 520 1000 48 220
50 150 670 820 2.2 98.75 98.39 1.36 51 740 600 1250 126 330
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 55 °C
Limits of temperature rise (winding) : not exceeding 65 °C
3. Insulation class : A
4. Polarity : Subtractive
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOH-1209
TECHNICAL DATA OF OIL-IMMERSED HERMETICALLY SEALED SINGLE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
26
Rated primary voltage : 12/24kV or 24kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
37.5 130 375 505 1.2 - 4.4 98.82 98.67 1.09 48 580 1050 1220 71 365
50 125 420 545 1.6 - 4.4 99.09 98.92 0.93 48 600 1080 1220 80 410
75 125 420 545 2.1 - 4.4 99.39 99.28 0.66 51 640 1160 1295 116 580
100 415 1525 1940 2.1 - 4.4 98.43 98.10 1.61 51 690 1600 1420 160 900
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 55 °C
Limits of temperature rise (winding) : not exceeding 55 °C
3. Insulation class : A
4. Polarity : Subtractive
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOCSP-1309
TECHNICAL DATA OF OIL-IMMERSED COMPLETELY SELF PROTECTED SINGLE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
27
Rated primary voltage : 12/24kV or 24kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
150 300 1000 1300 2.1 - 4.4 99.27 99.14 0.76 55 650 1560 1420 255 1230
225 415 1525 3050 3.2 - 4.4 99.30 98.66 0.77 55 690 1600 1420 340 1475
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (top oil) : not exceeding 55 °C
Limits of temperature rise (winding) : not exceeding 55 °C
3. Insulation class : A
4. Polarity : Subtractive
5. Reference standard : IEC 60076
6. Special vector group and other primary voltage available upon request
TME-TDOCSP-1409
TECHNICAL DATA OF OIL-IMMERSED COMPLETELY SELF PROTECTED THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
28
Rated primary voltage : 11/22kV, 22kV, 12/24kV, 24kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
250 1160 3390 4550 4.0 98.42 98.21 1.43 58 850 1430 1600
315 1200 4100 5300 4.0 98.61 98.35 1.37 60 850 1450 1800
400 1400 4800 6200 4.0 98.72 98.47 1.27 60 850 1600 1750
500 1650 5900 7550 4.0 98.77 98.51 1.25 60 900 1600 1900
630 1960 6900 8860 6.0 98.84 98.61 1.27 62 900 1650 1950
800 2300 8300 10600 6.0 98.92 98.69 1.21 64 900 1700 2000
1000 2660 9600 12260 6.0 99.00 98.79 1.14 64 1000 1800 2100
1250 3100 11800 14900 6.0 99.04 98.82 1.12 65 1000 1850 2200
1600 3800 14000 17800 6.0 99.10 98.90 1.05 66 1000 2050 2250
2000 5000 17000 22000 6.0 99.08 98.91 1.03 66 1100 2050 2350
2500 5800 20000 25800 6.0 99.14 98.98 0.98 68 1100 2100 2550
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 100 °C maximum
3. Insulation class : F
4. Connection symbol : Dyn 1 or Dyn 11
5. Reference standard : IEC Std
6. Special vector group, other primary voltage and overload capability available upon request
TME-TDDC-1509
1700
5400
6450
2350
2400
2800
3550
4000
4650
TECHNICAL DATA OF DRY TYPE CAST RESIN THREE PHASE TRANSFORMER WITHOUT ENCLOSURE (IP00)
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 1 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
TOTAL WEIGHT
Approx.
(kg)
1550
2200
29
Rated primary voltage : 11/22kV, 22kV, 12/24kV, 24kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
250 1160 3390 4550 4.0 98.42 98.21 1.43 58 1600 2350 2050
315 1200 4100 5300 4.0 98.61 98.35 1.37 60 1600 2350 2250
400 1400 4800 6200 4.0 98.72 98.47 1.27 60 1600 2500 2200
500 1650 5900 7550 4.0 98.77 98.51 1.25 60 1650 2500 2350
630 1960 6900 8860 6.0 98.84 98.61 1.27 62 1650 2550 2400
800 2300 8300 10600 6.0 98.92 98.69 1.21 64 1650 2600 2450
1000 2660 9600 12260 6.0 99.00 98.79 1.14 64 1750 2700 2550
1250 3100 11800 14900 6.0 99.04 98.82 1.12 65 1750 2750 2650
1600 3800 14000 17800 6.0 99.10 98.90 1.05 66 1750 2950 2700
2000 5000 17000 22000 6.0 99.08 98.91 1.03 66 1850 2950 2800
2500 5800 20000 25800 6.0 99.14 98.98 0.98 68 1850 3000 3000
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 100 °C maximum
3. Insulation class : F
4. Connection symbol : Dyn 1 or Dyn 11
5. Reference standard : IEC Std
6. Special vector group, other primary voltage and overload capability available upon request
TME-TDDC-1609
2300
7200
Note :
3050
3450
4250
4700
5350
6150
TECHNICAL DATA OF DRY TYPE CAST RESIN THREE PHASE TRANSFORMER WITH ENCLOSURE (IP21 OR IP31)
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 1 m
OUTLINE DIMENSION
Approx.(mm.)
TOTAL WEIGHT
Approx.
(kg)
2150
2800
3000
30
Rated primary voltage : 12/24kV, 22kV, 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
315 1200 4100 5300 4.0 98.61 98.35 1.37 60 900 1400 1290
400 1400 4800 6200 4.0 98.72 98.47 1.27 60 920 1500 1350
500 1650 5900 7550 4.0 98.77 98.51 1.25 60 940 1590 1380
630 1960 6900 8860 4.0 98.84 98.61 1.17 62 955 1680 1420
800 2300 8300 10600 6.0 98.92 98.69 1.21 64 975 1760 1450
1000 2660 9600 12260 6.0 99.00 98.79 1.14 64 1000 1840 1500
1250 3100 11800 14900 6.0 99.04 98.82 1.12 65 1030 1900 1550
1600 3800 14000 17800 6.0 99.10 98.90 1.05 66 1065 2070 1700
2000 5000 17000 22000 6.0 99.08 98.91 1.03 66 1080 2150 1920
2500 5800 20000 25800 7.0 99.14 98.98 1.04 68 1100 1820 2050
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 125 °C maximum
3. Insulation class : H (180°C)
4. Connection symbol : Dyn 11
5. Reference standard : IEC standard
6. Special vector group, other primary voltage and overload capability available upon request
TME-TDDV-1709
5300
Note :
2400
2700
2900
3400
4300
4800
TECHNICAL DATA OF VENTILATED DRY TYPE THREE PHASE TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 1 m
OUTLINE DIMENSION
Approx.(mm.)
TOTAL WEIGHT
Approx.
(kg)
1400
1750
2020
31
Rated primary voltage : 12/24kV, 22kV, 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
315 1200 4100 5300 4.0 98.61 98.35 1.37 60 1400 1850 1700
400 1400 4800 6200 4.0 98.72 98.47 1.27 60 1420 1950 1650
500 1650 5900 7550 4.0 98.77 98.51 1.25 60 1440 2040 1680
630 1960 6900 8860 4.0 98.84 98.61 1.17 62 1460 2130 1720
800 2300 8300 10600 6.0 98.92 98.69 1.21 64 1480 2210 1750
1000 2660 9600 12260 6.0 99.00 98.79 1.14 64 1500 2300 1800
1250 3100 11800 14900 6.0 99.04 98.82 1.12 65 1530 2370 1850
1600 3800 14000 17800 6.0 99.10 98.90 1.05 66 1570 2520 2080
2000 5000 17000 22000 6.0 99.08 98.91 1.03 66 1570 2600 2200
2500 5800 20000 25800 7.0 99.14 98.98 1.04 68 1600 2270 2350
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 125 °C maximum
3. Insulation class : H (180°C)
4. Connection symbol : Dyn 11
5. Reference standard : IEC 60726 or IEC 60076-11
6. Special vector group, other primary voltage and overload capability available upon request
TME-TDDV-1809
5350
5850
2350
2800
3150
3400
3850
4800
TECHNICAL DATA OF VENTILATED DRY TYPE THREE PHASE TRANSFORMER (IP21)
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 1 m
OUTLINE DIMENSION
Approx.(mm.)
TOTAL WEIGHT
Approx.
(kg)
Note :
1800
2100
32
Rated primary voltage : 100 V - 1000 V
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
10 130 340 470 4.0 95.88 95.51 3.42 25 250 360 400
15 200 500 700 4.0 95.85 95.54 3.36 30 270 420 450
20 300 650 950 4.0 95.58 95.47 3.28 30 300 480 500
25 335 760 1095 4.0 95.97 95.80 3.07 30 320 480 500
30 410 920 1330 4.0 95.91 95.75 3.10 30 340 540 550
40 530 1250 1780 4.0 95.96 95.74 3.16 30 380 600 600
50 600 1700 2300 4.0 96.06 95.60 3.42 30 380 660 650
60 670 2100 2770 4.0 96.17 95.59 3.52 40 400 720 700
80 770 2800 3570 4.0 96.46 95.73 3.52 40 430 720 700
100 830 3200 4030 4.0 96.84 96.13 3.23 40 450 780 750
120 960 3500 4460 4.0 97.03 96.42 2.95 40 480 780 780
150 1200 3900 5100 4.0 97.18 96.71 2.65 40 500 840 820
200 1600 4200 5800 4.0 97.42 97.18 2.16 40 540 840 850
250 2000 4500 6500 4.0 97.56 97.47 1.86 45 550 900 850
300 2500 5000 7500 4.0 97.56 97.56 1.73 45 580 900 880
1. The transformer is designed to operated under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 100 °C maximum
3. Insulation class : F (155 C)
4. Connection symbol : Dd 0 or Dyn 11
5. Reference standard : IEC 60726
6. Special vector group and other voltage available upon request
TME-TDCDT-01-10
1100
300
370
450
540
610
700
145
215
280
265
830
980
TECHNICAL DATA OF LOW VOLTAGE SEPARATED WINDING DRY TYPE THREE PHASE TRANSFORMER
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
TOTAL WEIGHT
Approx.
(kg)
80
113
33
Rated primary voltage : 100 V - 1000 V
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H
10 130 340 470 4.0 95.88 95.51 3.42 25 370 460 600
15 200 500 700 4.0 95.85 95.54 3.36 30 380 520 650
20 300 650 950 4.0 95.58 95.47 3.28 30 400 580 700
25 335 760 1095 4.0 95.97 95.80 3.07 30 420 580 700
30 410 920 1330 4.0 95.91 95.75 3.10 30 440 640 750
40 530 1250 1780 4.0 95.96 95.74 3.16 30 480 700 800
50 600 1700 2300 4.0 96.06 95.60 3.42 30 500 760 850
60 670 2100 2770 4.0 96.17 95.59 3.52 40 520 820 900
80 770 2800 3570 4.0 96.46 95.73 3.52 40 540 820 900
100 830 3200 4030 4.0 96.84 96.13 3.23 40 550 900 1000
120 960 3500 4460 4.0 97.03 96.42 2.95 40 550 900 1000
150 1200 3900 5100 4.0 97.18 96.71 2.65 40 650 1000 1100
200 1600 4200 5800 4.0 97.42 97.18 2.16 40 680 1000 1100
250 2000 4500 6500 4.0 97.56 97.47 1.86 45 750 1100 1150
300 2500 5000 7500 4.0 97.56 97.56 1.73 45 800 1100 1200
1. The transformer is designed to operated under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 100 °C maximum
3. Insulation class : F (155 C)
4. Connection symbol : Dd 0 or Dyn 11
5. Reference standard : IEC 60726
6. Special vector group and other voltage available upon request
7. The enclosures are designed to installation under IP21 standard
8. Other IP standard available upon request
TME-TDCDT-02-10
Note :
620
680
780
920
1070
1200
200
240
330
370
430
510
TECHNICAL DATA OF LOW VOLTAGE SEPARATED WINDING DRY TYPE THREE PHASE TRANSFORMER IP21
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
TOTAL WEIGHT
Approx.
(kg)
100
145
180
34
Rated primary voltage : 22kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 160 950 1110 4.0 98.43 97.83 1.96 48 710 920 890 80 320
100 250 1550 1800 4.0 98.74 98.23 1.62 51 705 1085 930 95 500
160 360 2100 2460 4.0 98.91 98.49 1.38 55 755 1270 1000 145 720
250 500 2950 3450 4.0 99.02 98.64 1.25 55 755 1340 1130 225 1075
315 600 3500 4100 4.0 99.07 98.72 1.18 56 850 1610 1680 385 1530
400 960 4150 5110 4.0 99.01 98.74 1.11 56 800 1520 1825 360 1640
500 860 4950 5810 6.5 or more 99.17 98.85 1.20 56 920 1770 1645 440 2000
630 1010 5850 6860 4.0 99.22 98.92 1.00 57 860 1780 1945 515 2470
1000 1270 12150 13420 6.0 99.15 98.68 1.39 58 1320 2210 1900 690 3265
1250 1500 14750 16250 6.0 99.18 98.72 1.35 60 1380 2130 2070 790 3730
1500 1820 17850 19670 6.0 99.17 98.71 1.36 60 1550 2410 2205 925 4390
2000 2110 21600 23710 6.0 99.25 98.83 1.25 61 1630 2620 2425 1250 6095
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise, above 40C ambient temperature
Of top oil : not exceeding 60 K
Of winding : not exceeding 65 K
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : TIS 384
6. Reference specification : RTRN-008/2552
7. Special vector group and other primary voltage available upon request
* The transformer of 50 kVA to 500 kVA will be permanently sealed and completely oil filled system (without gas cushion) type (usually corrugated tank).
The transformer of 630 kVA to 2000 kVA will be conservator system type.
TME-TDPEA22-0112
TECHNICAL DATA OF THREE PHASE TRANSFORMER DISTRIBUTION SYSTEM (PEA)
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
35
Rated primary voltage : 33kV
CAPACITYNO-LOAD
LOSSES
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 170 950 1120 4.0 98.40 97.81 1.96 48 740 950 1030 108 395
100 260 1550 1810 4.0 98.72 98.22 1.62 51 770 1260 1120 155 615
160 370 2100 2470 4.0 98.89 98.48 1.38 55 760 1260 1250 210 900
250 520 2950 3470 4.0 99.00 98.63 1.25 55 820 1325 1280 265 1180
315 630 3500 4130 4.0 99.05 98.71 1.18 56 810 1640 1880 355 1525
400 750 4150 4900 4.0 99.11 98.79 1.11 56 830 1640 1945 395 1775
500 900 4950 5850 6.5 or more 99.15 98.84 1.20 56 950 1580 1760 480 2090
630 1050 5850 6900 4.0 99.21 98.92 1.00 57 865 1820 2060 505 2385
1000 1300 12150 13450 6.0 99.14 98.67 1.39 58 1310 1775 2140 765 3365
1250 1530 14750 16280 6.0 99.17 98.71 1.35 60 1320 2200 2200 865 3905
1500 1850 17850 19700 6.0 99.17 98.70 1.36 60 1510 2220 2325 1050 4565
2000 2140 21600 23740 6.0 99.25 98.83 1.25 61 1630 2370 2560 1305 6100
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise, above 40C ambient temperature
Of top oil : not exceeding 60 K
Of winding : not exceeding 65 K
3. Insulation class : A
4. Connection symbol : Dyn 11
5. Reference standard : TIS 384
6. Reference specification : RTRN-008/2552
7. Special vector group and other primary voltage available upon request
* The transformer of 50 kVA to 500 kVA will be permanently sealed and completely oil filled system (without gas cushion) type (usually corrugated tank).
The transformer of 630 kVA to 2000 kVA will be conservator system type.
TME-TDPEA33-0112
TECHNICAL DATA OF THREE PHASE TRANSFORMER DISTRIBUTION SYSTEM (PEA)
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
36
Rated primary voltage : 12-24kV
CAPACITY
LOAD
LOSSES
AT 30 °C
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
50 205 1050 1255 1.2 - 4.4 98.16 97.55 2.17 48 600 960 1200 125 680
112.5 340 1800 2140 1.5 - 4.4 98.62 98.13 1.68 51 650 1080 1290 185 825
150 450 2350 2800 1.6 - 4.4 98.64 98.17 1.65 55 660 1100 1290 195 870
225 680 3900 4580 3.9 - 7.0 98.55 98.01 1.96 56 700 1200 1400 235 1050
400 830 4600 5430 3.9 - 7.0 99.02 98.66 1.39 56 740 1300 1560 370 1620
500 970 5500 6470 3.9 - 7.0 99.07 98.72 1.34 56 820 1470 1670 428 1880
630 1120 6500 7620 3.9 - 7.0 99.14 98.80 1.27 57 850 1370 1590 420 2040
800 1300 10500 11800 > 6.0 99.03 98.55 1.48 58 950 1600 1650 610 2500
1000 1420 12500 13920 > 6.0 99.10 98.63 1.42 58 1050 1700 1730 750 3100
1250 1600 14750 16350 > 6.0 99.16 98.71 1.35 60 1440 2300 1900 920 3700
1500 1840 17800 19640 > 6.0 99.17 98.71 1.36 60 1400 2300 1900 1037 4400
1600 2100 19500 21600 > 6.0 99.14 98.67 1.39 61 1540 2380 1970 1030 4960
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise, above 40C ambient temperature
Of top oil : not exceeding 55 C
Of winding : not exceeding 55 C
3. Insulation class : A
4. Connection symbol : Dyn 1
5. Reference standard : TIS 384-2543, IEC 60076
6. Reference specification : 240:07-2003
7. Special vector group and other primary voltage available upon request
TME-TDMEA240-0112
TECHNICAL DATA OF THREE PHASE TRANSFORMER (CONVENTIONAL TYPE) (MEA)
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
37
Rated primary voltage : 12-24kV
CAPACITY
LOAD
LOSSES
AT 30 °C
LOAD
LOSSES
AT 75 °C
TOTAL
LOSSES
AT 75 °C
IMPEDANCE
AT 75 °C
VOLTAGE
REGULATION
AT FULL LOAD
(P.F.=1)
OIL
QTY.
TOTAL
WEIGHT
Approx.
(kVA) (Watt) (Watt) (Watt) (%)½ Load
(%)
Full Load
(%)(%) W L H (lt) (kg)
300 480 1860 2340 3.9 - 7.0 99.37 99.23 0.86 48 600 960 1200 125 680
500 670 3030 3700 > 6.5 99.43 99.27 0.82 51 650 1080 1290 185 825
750 840 2350 3190 > 6.5 99.62 99.58 0.52 55 660 1100 1290 195 870
1000 1000 6400 7400 > 6.5 99.48 99.27 0.85 61 1540 2380 1970 1030 4960
1. The transformer is designed to operate under the following conditions
Altitude : Up to 1000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise, above 40C ambient temperature
Of top oil : not exceeding 55 C
Of winding : not exceeding 55 C
3. Insulation class : A
4. Connection symbol : Dyn 1
5. Reference standard : TIS 384-2543, IEC 60076
6. Reference specification : 233:10-2007
7. Special vector group and other primary voltage available upon request
TME-TDMEA233-0112
TECHNICAL DATA OF THREE PHASE TRANSFORMER (LOW LOSSES) (MEA)
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
EFFICIENCY
(P.F.=1) NOISE
LEVEL dB
(A) : 0.3 m
OUTLINE DIMENSION
Approx.(mm.)
Note :
38
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Primary rated current A
Secondary rated current A
Rated short-time thermal current Ith (1s) kArms
Rated dynamic current Idyn (1s)
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 19 26
DIMENSION :
- W x L x H mm 260 x 300 x 335 420 x 300 x 515
* Specifications and product design are subject to change without notice for futher improvement
TME-TDCCT-1201
-5…. + 40 C
not exceed 1000 m.
IEC 60044-1, IEEE C57.13-1993
22
240 x 280 x 430
TECHNICAL DATA OF CAST RESIN CURRENT TRANSFORMER (OUTDOOR TYPE)
Th
e c
on
ten
ts a
nd
sp
ecific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
DESCRIPTIONTYPE
50, 60
10 - 2500
1, 5
16
40
E
39
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Primary rated current A
Primary reconnection
Secondary rated current A
Rated short-time thermal current Ith (1s) kArms
Rated dynamic current Idyn (1s)
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 24 - 30 32 - 40 32 - 40 38 - 48
DIMENSION :
148 x 350 x 220 178 x 360 x 295 178 x 360 x 295
w mm 125 150 150 150
l mm 270±5.0 280±5.0 280±5.0 280±5.0
l1 mm 290 300 300 300
l2 mm 145 150 150 150
l3 mm 130 135 135 135
d1 mm 21 29 29 29
d2 mm 11 14 14 14
* Specifications and product design are subject to change without notice for futher improvement
TME-TDCC-2209-01
100 (max)
2.5 x Ith
TECHNICAL DATA OF CAST RESIN CURRENT TRANSFORMER (INDOOR TYPE)
TYPEup to 2 cores
50, 60
10 - 2500
2 x 10 A - 2 x 600 AT
he
co
nte
nts
an
d s
pe
cific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
E
-5 .. + 40 °C
not exceed 1000 m
IEC 60044-1, IEEE C57.13-1993
W x L x H mm 207 x 360 x 330According to DIN 42600, part 8
1, 5
40
Double pole
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Rated primary voltage kV 11, 22 15, 17.5 22, 24 33
Secondary voltage V
Rated burden in class 0.2
0.5
1.0
3.0
3P
6P
Rated voltage factor
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 27 50
- W x L x H mm 280 x 250 x 390 385 x 430 x 605
* Specifications and product design are subject to change without notice for futher improvement
TME-TDCPT-1201
IEC 60044-2, IEEE C57.13-1993
36
350 x 350 x 490
150 VA
150 VA
1.2 for continuous
E
-5… + 40 C
not exceed 1000 m.
TECHNICAL DATA OF CAST RESIN VOLTAGE TRANSFORMER (OUTDOOR TYPE)
Th
e c
on
ten
ts a
nd
sp
ecific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
DESCRIPTIONTYPE
50, 60
100, 110, 120
25 VA
50 VA
100 VA
200 VA
41
Single pole
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Rated primary voltage kV 11/3, 12/3 15/3, 17.5/3 22/3, 24/3 33/3
Secondary voltage V
Rated burden in class 0.2
0.5
1.0
3.0
3P
6P
Rated voltage factor
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 28 - 35 31 - 39 33 - 40 39 - 49
l1 mm 400
l2 mm 380±5.0
l3 mm 185
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Rated primary voltage kV 11, 12 15, 17.5 22, 24 33
Secondary voltage V
Rated burden in class 0.2
0.5
1.0
3.0
3P
6P
Rated voltage factor
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 28 - 35 31 - 39 33 - 40 39 - 49
l1 mm 400
l2 mm 380±5.0
l3 mm 185
l4 mm 320
* Specifications and product design are subject to change without notice for futher improvement
TME-TDCP-2409-01
TECHNICAL DATA OF CAST RESIN VOLTAGE TRANSFORMER (INDOOR TYPE)
Th
e c
onte
nts
and
sp
ecific
atio
ns o
f th
is d
ata
she
et
are
su
bje
ct
to c
han
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of
this
data
ma
y b
e r
epro
du
ced
with
ou
t th
e p
rio
r a
pp
roval o
f T
hai M
axw
ell
Ele
ctr
ic.
TYPEup to 2 cores
50, 60
100/3, 110/3, 120/3
25 VA
50 VA
100 VA
According to DIN 42600, part 8
200 VA
150 VA
150 VA
1.2 for continuous
E
-5 .. + 40 °C
300
280±5.0
135
not exceed 1000 m
IEC 60044-2, IEEE C57.13-1993
W x L x H mm 178 x 360 x 280178 x 360 x 280
207 x 460 x 340
E
-5 .. + 40 °C
50, 60
100, 110, 120
25 VA
50 VA
100 VA
220
W x L x H mm 178 x 360 x 285178 x 360 x 285
not exceed 1000 m
IEC 60044-2, IEEE C57.13-1993
Double pole
207 x 460 x 345According to DIN 42600, part 8
300
280±5.0
135
200 VA
150 VA
150 VA
1.2 for continuous
42
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Primary rated current A
Secondary rated current A
Rated short-time thermal current Ith (1s) kArms
Rated dynamic current Idyn (1s)
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 47
DIMENSION :
- W x L x H mm 330 x 510 x 740
* Specifications and product design are subject to change without notice for futher improvement
TME-TDOCT-1201
-5…. + 40 C
not exceed 1000 m.
IEC 60044-1, IEEE C57.13-1993
34
330 x 510 x 640
TECHNICAL DATA OF OIL IMMERSED CURRENT TRANSFORMER (OUTDOOR TYPE)
Th
e c
on
ten
ts a
nd
sp
ecific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
DESCRIPTIONTYPE
50, 60
10 - 2500
1, 5
16
40
A
43
Double pole
12 17.5 24 36
Operating voltage (maximum) kV 12 17.5 24 36
Rated power-frequency withstand voltage (1 min) kVrms 28 38 50 70
Rated Impulse test voltage (1.2/50µs) full wave kVp 75 95 125 170
Rated frequency Hz
Rated primary voltage kV 11, 22 15, 17.5 22, 24 33
Secondary voltage V
Rated burden in class 0.2
0.5
1.0
3.0
3P
6P
Rated voltage factor
Insulation class
Ambient temperature
Altitude
Standard
Weight kgs 60
- W x L x H mm 335 x 500 x 850
* Specifications and product design are subject to change without notice for futher improvement
TME-TDOPT-1201
IEC 60044-2, IEEE C57.13-1993
50
300 x 430 x 670
150 VA
150 VA
1.2 for continuous
A
-5… + 40 C
not exceed 1000 m.
TECHNICAL DATA OF OIL IMMERSED VOLTAGE TRANSFORMER (OUTDOOR TYPE)
Th
e c
on
ten
ts a
nd
sp
ecific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
DESCRIPTIONTYPE
50, 60
100, 110, 120
25 VA
50 VA
100 VA
200 VA
44
Rated primary voltage : 0.72 kV
W L H
73 85 101
1. The transformer is designed to operated under the following conditions
Altitude : up to 1,000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : not exceeding 60 °C
3. Insulation Class : E
4. Reference standard : DIN 42600, VDE 0414, IEC 60044-1
TME-TDPC-0109
5 100 - 600 5 0.5, FS=5 1
Note :
(Maximum)
(VA) (A) (A) (%) (kg)
TECHNICAL DATA OF PLASTIC RING TYPE CURRENT TRANSFORMER
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
RATED OUTPUTPRIMARY CURRENT SECONDARY CURRENT ACCURACY CLASS
OUTLINE DIMENSION TOTAL WEIGHT
(BURDEN) (Maximum in mm.)
45
Rated primary voltage : 0.660 kV(IEC), 0.720 kV(ANSI)
W L H
60 160 160
1. The transformer is designed to operated under the following conditions
Altitude : up to 1,000 m above sea level
Ambient air temperature : 40 °C maximum
2. Limits of temperature rise (winding) : 55 °C at 30 °C ambient temperature
3. Insulation Class : E
4. Reference standard : DIN 42600, VDE 0414, IEC 60044-1, ANSI C57.13
TME-TDPC-0109
B-0.1, B-0.2, B-0.5 200 - 3000 5 0.6 at B-0.1, B-0.2
and B-0.53
Note :
(Maximum)
(VA) (A) (A) (%) (kg)
TECHNICAL DATA OF CAST RESIN RING TYPE CURRENT TRANSFORMER (outdoor and indoor)
The c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
RATED OUTPUTPRIMARY CURRENT SECONDARY CURRENT ACCURACY CLASS
OUTLINE DIMENSION TOTAL WEIGHT
(BURDEN) (Maximum in mm.)
46
TYPE / MODEL GLBS-2M GLBS-3M
Rated voltage kV 22 33
Rated frequency Hz
Rated normal current A 630 400
Rated symmetrical interrupting current A 630 400
Rated short-time withstand current, I - second kV (r.m.s.) 12.5 10
Rated short-circuit making current kA (peak) 31.25 25
Rated power frequency withstand voltage, 1 - minute kV (r.m.s.) 60 70
Rated impulse withstand voltage kV (peak) 145 170
Rated mainly active load breaking capacity A 630 400
Rated transformer off-load breaking capacity A
Rated cable-charging breaking capacity A
Time to open, at rated normal current seconds
Time to close seconds
Maximum temperature rise of
- Contacts K
- Current carrying parts K
- Mechanical parts K
Number of operations
- Mechanical -
- Electrical (at rated normal current interruption) -
Rated pressure range of SF6 gas PSI
Low pressure alarm PSI
Pressure of SF6 when locking device operates PSI
Protection degree of assembled enclosure -
Operation force of handle kgf
Conductor material of main circuit leads -
Cross section area of main circuit lead mm2 185 125
Creepage distance of bushing or supporting insulator, from live part to ground mm 600 900
Net weight kg 170
Dimension (W x L x H) mm 920 x 1050 x 520 1070 x 1208 x 520
TME-TDLBS-0111
Copper
400
14.5
8.7 - 10.1
4.3 - 7.2
IP 65
18
TECHNICAL DATA OF SF GAS LOAD BREAK SWITCH (SF LBS)
Th
e c
on
ten
ts a
nd
sp
ecific
atio
ns o
f th
is d
ata
sh
ee
t a
re s
ub
ject to
ch
an
ge
with
ou
t p
rio
r n
otice
. N
o p
art
of th
is d
ata
ma
y b
e r
ep
rod
uce
d w
ith
ou
t th
e p
rio
r a
pp
rova
l o
f T
ha
i M
axw
ell
Ele
ctr
ic.
50
14 (21)
20
< 0.7
< 0.7
< 65 < 50
2,000
6 6
47
STEEL CABLE LADDER
STRAIGHT
T = 1.0 mm. T = 1.6 mm. T = 2.0 mm. 1.5 m. 2.0 m. 3.0 m.
5.88 2.83 3.77 1371.75 1083.00 737.05
6.32 4.00 5.34 1292.85 1020.50 695.25
6.76 5.17 6.91 1220.00 963.80 656.60
7.20 6.34 8.48 1167.45 921.95 628.75
7.64 7.51 10.05 1105.20 872.95 595.75
8.08 8.68 11.62 1022.40 801.95 545.90
8.52 9.85 13.19 975.45 770.75 526.95
8.96 11.02 14.76 912.45 720.50 488.60
9.40 12.19 16.33 580.35 671.50 456.65
Note :
STANDARD : BS, NEMA, E.I.T
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
: Powder Paint Coating 60-80 µM. Thickness : Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0109
LH 800 x 100 x 3000
TECHNICAL DATA OF CABLE TRAY SYSTEM
WEIGHT ( kg./m )
COVER
BENDING STRENGHT ( kg. / m )
SUPPORT DISTANCE ( m. )
LH 300 x 100 x 3000
LH 200 x 100 x 3000
LH 900 x 100 x 3000
LH 1000 x 100 x 3000
(W x H x L)
TYPE
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
LH 400 x 100 x 3000
LH 500 x 100 x 3000
LH 600 x 100 x 3000
LH 700 x 100 x 3000
48
STEEL CABLE LADDER
90 HORIZONTAL BEND
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
6.16 3.08 4.12
7.28 4.66 6.22
8.99 6.48 8.64
10.26 8.53 11.37
12.42 10.81 14.41
13.83 13.37 17.77
15.25 16.09 21.45
16.66 19.08 25.44
18.06 22.30 29.74
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0209
90HB-LH 300 x 100
90HB-LH 900 x 100
90HB-LH 500 x 100
90HB-LH 600 x 100
90HB-LH 700 x 100
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
90HB-LH 400 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
TYPE
(W x H)
90HB-LH 800 x 100
WEIGHT (kg. / m.)
COVER
90HB-LH 1000 x 100
90HB-LH 200 x 100
49
STEEL CABLE LADDER
HORIZONTAL TEE
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
7.09 4.42 5.88
8.14 6.45 8.58
9.71 8.71 11.6
11.54 11.20 14.94
12.85 13.94 18.57
14.15 16.90 22.53
15.46 20.11 26.8
17.95 23.54 31.38
19.39 27.22 36.28
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0309
HT-LH 200 x 100
HT-LH 300 x 100
HT-LH 400 x 100
HT-LH 500 x 100
HT-LH 600 x 100
HT-LH 700 x 100
HT-LH 800 x 100
HT-LH 900 x 100
HT-LH 1000 x 100 The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TECHNICAL DATA OF CABLE TRAY SYSTEM
TYPEWEIGHT (kg. / m.)
(W x H)COVER
50
STEEL CABLE LADDER
90 VERTICAL OUTSIDE BEND
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
4.92 2.00 2.50
5.37 2.81 3.50
5.82 3.62 4.50
6.27 4.43 5.50
6.72 5.24 6.50
7.17 6.05 7.50
7.62 6.86 8.50
8.07 7.67 9.50
8.52 8.48 10.50
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0409
90VO-LH 200 x 100
90VO-LH 300 x 100
90VO-LH 400 x 100
90VO-LH 500 x 100
90VO-LH 600 x 100
90VO-LH 700 x 100
90VO-LH 800 x 100
90VO-LH 900 x 100
90VO-LH 1000 x 100 The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TECHNICAL DATA OF CABLE TRAY SYSTEM
TYPEWEIGHT (kg. / m.)
(W x H)COVER
51
STEEL CABLE LADDER
90 VERTICAL INSIDE BEND
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
4.62 1.60 2.00
5.44 2.26 2.83
6.25 2.93 3.66
7.06 3.60 4.50
7.87 4.27 5.33
8.69 4.94 6.17
9.50 5.61 7.00
10.31 6.28 7.83
11.12 6.95 8.66
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0509
90VI-LH 200 x 100
90VI-LH 300 x 100
90VI-LH 400 x 100
90VI-LH 500 x 100
90VI-LH 600 x 100
90VI-LH 700 x 100
90VI-LH 800 x 100
90VI-LH 900 x 100
90VI-LH 1000 x 100 The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TECHNICAL DATA OF CABLE TRAY SYSTEM
TYPEWEIGHT (kg. / m.)
(W x H)COVER
52
STEEL CABLE LADDER
HORIZONTAL CROSS
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
10.51 5.78 7.22
13.15 8.49 10.61
16.03 11.20 14.00
14.17 14.14 17.68
17.06 17.32 21.65
20.19 20.73 25.91
23.58 24.38 30.48
27.22 28.27 35.34
38.60 32.39 40.48
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0609
HX-LH 200 x 100
HX-LH 300 x 100
HX-LH 400 x 100
HX-LH 500 x 100
HX-LH 600 x 100
HX-LH 700 x 100
HX-LH 800 x 100
HX-LH 900 x 100
HX-LH 1000 x 100 The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TECHNICAL DATA OF CABLE TRAY SYSTEM
TYPEWEIGHT (kg. / m.)
(W x H)COVER
53
STEEL CABLE LADDER
HORIZONTAL REDUCE
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
4.76 2.52 3.15
5.51 3.27 4.10
6.27 4.02 5.02
7.02 4.77 5.96
7.78 5.52 6.90
8.53 6.27 7.83
9.28 7.02 8.78
10.04 7.77 9.72
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0709
HR-LH 500, W2 x 100
HR-LH 600, W2 x 100
HR-LH 700, W2 x 100
HR-LH 800, W2 x 100
HR-LH 900, W2 x 100
HR-LH 1000, W2 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
HR-LH 300, W2 x 100
HR-LH 400, W2 x 100
54
STEEL CABLE TRAY
STRAIGHT
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm. 1.5 m. 2.0 m. 3.0 m.
7.63 2.83 3.77 1205.5 928.00 638.95
8.86 4.00 5.34 1367.35 1079.95 726.70
10.09 5.17 6.91 1450.80 1146.15 769.85
11.32 6.34 8.48 1512.65 1202.10 806.45
12.55 7.51 10.05 1605.20 1268.11 850.00
13.78 8.68 11.62 1735.35 1370.90 919.75
15.01 9.85 13.19 1842.10 1455.50 976.35
16.24 11.02 14.76 1960.70 1548.95 1039.15
17.47 12.19 16.33 2065.20 1631.50 1096.55
Note :
STANDARD : BS, NEMA, E.I.T
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
: Powder Paint Coating 60-80 µM. Thickness : Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCL-0809
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPE WEIGHT ( kg./m ) BENDING STRENGHT ( kg. / m )
(W x H x L)COVER SUPPORT DISTANCE ( m. )
VH 200 x 100 x 3000
VH 300 x 100 x 3000
VH 1000 x 100 x 3000
VH 400 x 100 x 3000
VH 500 x 100 x 3000
VH 600 x 100 x 3000
VH 700 x 100 x 3000
VH 800 x 100 x 3000
VH 900 x 100 x 3000
55
STEEL CABLE TRAY
90 HORIZONTAL BEND
FITTING
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm.
7.02 3.08 4.12
9.16 4.66 6.22
11.54 6.48 8.64
14.17 8.53 11.37
17.06 10.81 14.41
20.19 13.37 17.77
23.58 16.09 21.45
27.22 19.08 25.44
31.11 22.30 29.74
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-0909
90HB-VH 200 x 100
90HB-VH 300 x 100
90HB-VH 400 x 100
90HB-VH 500 x 100
90HB-VH 600 x 100
90HB-VH 700 x 100
90HB-VH 800 x 100
90HB-VH 900 x 100
90HB-VH 1000 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
56
STEEL CABLE TRAY
HORIZONTAL TEE
FITTING
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm.
7.02 4.42 5.88
9.16 6.45 8.58
11.54 8.71 11.60
14.17 11.20 14.94
17.06 13.94 18.57
20.19 16.90 22.53
23.58 20.11 26.80
27.22 23.54 31.38
31.11 27.22 36.28
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-1009
HT-VH 200 x 100
HT-VH 300 x 100
HT-VH 400 x 100
HT-VH 500 x 100
HT-VH 600 x 100
HT-VH 700 x 100
HT-VH 800 x 100
HT-VH 900 x 100
HT-VH 1000 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
57
STEEL CABLE TRAY
90 VERTICAL OUTSIDE BEND
FITTING
T = 2.0 mm. T = 1.6 mm. T = 2.0 mm.
4.18 2.00 2.50
4.77 2.81 3.50
5.36 3.62 4.50
5.94 4.43 5.50
6.53 5.24 6.50
7.12 6.05 7.50
7.71 6.86 8.50
8.30 7.67 9.50
8.89 8.48 10.50
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-1109
90VO-VH 200 x 100
90VO-VH 300 x 100
90VO-VH 400 x 100
90VO-VH 500 x 100
90VO-VH 600 x 100
90VO-VH 700 x 100
90VO-VH 800 x 100
90VO-VH 900 x 100
90VO-VH 1000 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
58
STEEL CABLE TRAY
90 VERTICAL INSIDE BEND
FITTING
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm.
4.62 1.60 2.00
5.44 2.26 2.83
6.25 2.93 3.66
7.06 3.60 4.50
7.87 4.27 5.33
8.69 4.94 6.17
9.50 5.61 7.00
10.31 6.28 7.83
11.12 6.95 8.66
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-1209
90VI-VH 200 x 100
90VI-VH 300 x 100
90VI-VH 400 x 100
90VI-VH 500 x 100
90VI-VH 600 x 100
90VI-VH 700 x 100
90VI-VH 800 x 100
90VI-VH 900 x 100
90VI-VH 1000 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
59
STEEL CABLE TRAY
HORIZONTAL CROSS
FITTING
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm.
10.51 5.78 7.22
13.15 8.49 10.61
16.03 11.20 14.00
14.17 14.14 17.68
17.06 17.32 21.65
20.19 20.73 25.91
23.58 24.38 30.48
27.22 28.27 35.34
38.60 32.39 40.48
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-1309
HX-VH 200 x 100
HX-VH 300 x 100
HX-VH 400 x 100
HX-VH 500 x 100
HX-VH 600 x 100
HX-VH 700 x 100
HX-VH 800 x 100
HX-VH 900 x 100
HX-VH 1000 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
60
STEEL CABLE TRAY
HORIZONTAL REDUCE
FITTING
T = 2.0/1.6 mm. T = 1.6 mm. T = 2.0 mm.
4.76 2.52 3.15
5.51 3.27 4.10
6.27 4.02 5.02
7.02 4.77 5.96
7.78 5.52 6.90
8.53 6.27 7.83
9.28 7.02 8.78
10.04 7.77 9.72
Note :
STANDARD : BS, NEMA, E.I.T.
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSCT-1409
HR-VH 500, W2 x 100
HR-VH 600, W2 x 100
HR-VH 700, W2 x 100
HR-VH 800, W2 x 100
HR-VH 900, W2 x 100
HR-VH 1000, W2 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
The c
onte
nts
and s
peci
fica
tions
of th
is d
ata
sheet
are
subje
ct t
o c
hange w
ithout
prior
notice
. N
o p
art
of th
is d
ata
may b
e r
epro
duce
d w
ithout
the p
rior
appro
val of Thai M
axw
ell
Ele
ctric.
TYPEWEIGHT (kg. / m.)
(W x H)COVER
HR-VH 300, W2 x 100
HR-VH 400, W2 x 100
61
STEEL WIRE WAY
1.5 2.0 1.5 2.0 1.5 2.0 1.5 2.0
2.37 276.55 221.25 2.85 370.50 296.40 3.56 583.35 452.20 4.74 906.80 687.80
2.76 318.25 254.60 3.32 408.50 326.80 4.15 632.10 490.00 5.53 971.85 725.50
3.16 349.50 277.40 3.79 463.35 369.35 4.73 695.30 539.00 6.31 1009.20 767.60
3.55 387.00 305.00 4.26 500.80 395.20 5.32 749.95 581.35 7.10 1067.45 798.75
4.33 395.00 334.40 5.20 562.00 443.70 6.33 796.30 627.00 8.78 1105.85 817.70
5.12 418.00 357.20 6.14 602.15 477.90 7.68 852.95 661.20 10.24 1197.65 921.30
- - - 7.08 645.17 514.70 8.86 884.90 696.80 11.81 1265.50 980.40
- - - 8.02 690.97 554.88 10.04 994.45 743.65 13.38 1326.10 1012.50
- - - - - - 11.22 987.45 785.40 14.95 1377.45 1067.80
- - - - - - 12.40 1046.35 823.90 16.52 1419.95 1113.40
- - - - - - 13.58 1076.20 847.40 18.09 1482.60 1128.50
- - - - - - 14.76 1134.80 900.00 19.66 1530.70 1188.00
Note :
STANDARD : BS, NEMA, E.I.T
MATERIALS : Cold Rolled Mild Steel Sheet
: Hot Rolled Mild Steel Sheet
: Galvanized Steel Sheet
: Aluzinc Steel Sheet
: Stainless Steel Sheet
FINISHING : Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. Thickness: Hot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-1509
WP 150 x 100 x 2440
WP 200 x 100 x 2440
1.6 mm. 2.0 mm.
WP 400 x 100 x 2440
WP 450 x 100 x 2440
WEIGHT
(kg.)
S.D. ( m. )
WEIGHT
(kg.)
S.D. ( m. )
WP 300 x 100 x 2440
WP 350 x 100 x 2440
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
(W x H x L)
TYPE
WP 250 x 100 x 2440
WP 500 x 100 x 2440
TECHNICAL DATA OF CABLE TRAY SYSTEM
BENDING STRENGHT ( kg. / m )
STEEL SHEET THICKNESS ( mm.)
1.0 mm. 1.2 mm.
WP 75 x 50 x 2440
WP 100 x 50 x 2440
WP 100 x 75 x 2440
WP 100 x 100 x 2440
S.D. ( m. )
WEIGHT
(kg.)
S.D. ( m. )
WEIGHT
(kg.)
62
STEEL WIRE WAY
90 HORIZONTAL BEND
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.35 0.42 0.56 0.70
0.43 0.52 0.69 0.86
0.58 0.70 0.93 1.16
0.69 0.83 1.10 1.38
0.96 1.15 1.51 1.89
1.24 1.49 1.98 2.48
- 1.89 2.52 3.15
- 2.33 3.11 3.89
- - 3.77 4.72
- - 4.49 5.62
- - 5.28 6.60
- - 6.14 7.66
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-1609
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
90HB-WP 200 x 100
THICKNESS
90HB-WP 100 x 50
90HB-WP 100 x 75
90HB-WP 100 x 100
90HB-WP 150 x 100
90HB-WP 75 x 50
TECHNICAL DATA OF CABLE TRAY SYSTEM
WEIGHT (kg.)
:
:
:
:
90HB-WP 300 x 100
90HB-WP 500 x 100
90HB-WP 350 x 100
90HB-WP 400 x 100
90HB-WP 450 x 100
TYPE
(W x H)
90HB-WP 250 x 100
:
:
:
:
63
STEEL WIRE WAY
HORIZONTAL TEE
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
1.31 1.57 2.10 2.62
1.55 1.86 2.48 3.10
1.76 2.11 2.82 3.52
1.94 2.33 3.10 3.88
2.49 2.99 3.98 4.98
3.12 3.74 4.99 6.24
- 4.50 6.00 7.50
- 5.44 7.25 9.08
- - 8.65 10.84
- - 10.16 12.70
- - 11.80 14.75
- - 13.57 19.60
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-1709
HT-WP 100 x 100
HT-WP 150 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
WEIGHT (kg.)
THICKNESS
HT-WP 75 x 50
HT-WP 100 x 50
HT-WP 100 x 75
:
:
:
HT-WP 200 x 100
HT-WP 250 x 100
HT-WP 300 x 100
HT-WP 350 x 100
HT-WP 400 x 100
HT-WP 450 x 100
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
:
:
:
TYPE
(W x H)
HT-WP 500 x 100
:
:
64
STEEL WIRE WAY
90 VERTICAL OUTSIDE BEND
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.70 0.84 1.12 1.40
0.82 0.98 1.31 1.64
1.13 1.36 1.81 2.26
1.35 1.62 2.16 2.70
1.62 1.94 2.59 3.24
1.89 2.27 3.02 3.78
- 2.60 3.46 4.33
- 2.91 3.90 4.87
- - 4.33 5.42
- - 4.76 5.96
- - 5.20 6.50
- - 5.63 7.04
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-1809
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
90VO-WP 75 x 50
90VO-WP 100 x 50
90VO-WP 100 x 75
90VO-WP 100 x 100
:
90VO-WP 150 x 100
90VO-WP 200 x 100
90VO-WP 250 x 100
90VO-WP 300 x 100
90VO-WP 350 x 100
90VO-WP 400 x 100
:
:
:
:
90VO-WP 450 x 100
90VO-WP 500 x 100
:
:
:
65
STEEL WIRE WAY
FLANG END
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.08 0.10 0.13 0.16
0.09 0.11 0.14 0.18
0.10 0.12 0.16 0.20
0.11 0.13 0.18 0.22
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-1909
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(H)
FE-WP 50
FE-WP 75
FE-WP 100
FE-WP 150
:
:
:
:
:
:
:
:
66
STEEL WIRE WAY
90 VERTICAL INSIDE BEND
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.70 0.84 1.12 1.40
0.82 0.98 1.31 1.64
1.13 1.36 1.81 2.26
1.35 1.62 2.16 2.70
1.62 1.94 2.59 3.24
1.89 2.27 3.02 3.78
- 2.60 3.46 4.33
- 2.91 3.90 4.87
- - 4.33 5.42
- - 4.76 5.96
- - 5.20 6.50
- - 5.63 7.04
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-2009
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
90VI-WP 75 x 50
90VI-WP 100 x 50
90VI-WP 100 x 75
90VI-WP 100 x 100
:
90VI-WP 150 x 100
90VI-WP 200 x 100
90VI-WP 250 x 100
90VI-WP 300 x 100
90VI-WP 350 x 100
90VI-WP 400 x 100
:
:
:
:
90VI-WP 450 x 100
90VI-WP 500 x 100
:
:
:
67
STEEL WIRE WAY
HORIZONTAL CROSS
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
1.80 2.16 2.88 3.60
2.08 2.50 3.33 4.16
2.37 2.84 3.79 4.47
2.57 3.08 4.11 5.14
3.18 3.82 5.09 6.36
3.86 4.63 6.18 7.72
- 5.35 7.13 8.91
- 6.35 8.47 10.59
- - 9.94 12.43
- - 11.54 14.42
- - 13.26 16.57
- - 15.16 18.88
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-2109
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
HX-WP 75 x 50
HX-WP 100 x 50
HX-WP 100 x 75
HX-WP 100 x 100
:
HX-WP 150 x 100
HX-WP 200 x 100
HX-WP 250 x 100
HX-WP 300 x 100
HX-WP 350 x 100
HX-WP 400 x 100
:
:
:
:
HX-WP 450 x 100
HX-WP 500 x 100
:
:
:
68
STEEL WIRE WAY
HORIZONTAL REDUCE
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.54 0.65 0.86 1.08
0.85 1.02 1.36 1.70
1.00 1.20 1.60 2.00
- 1.31 1.75 2.33
- 1.50 2.00 2.66
- - 2.25 2.99
- - 2.50 3.52
- - 2.75 3.61
- - 3.00 3.97
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-2209
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
HR-WP 100, 75 x 50
HR-WP 150, 100 x 100
HR-WP 200, W2 x 100
HR-WP 250, W2 x 100
HR-WP 300, W2 x 100
HR-WP 350, W2 x 100
HR-WP 400, W2 x 100
HR-WP 450, W2 x 100
HR-WP 500, W2 x 100
TECHNICAL DATA OF CABLE TRAY SYSTEM
:
:
:
:
:
:
:
:
69
STEEL WIRE WAY
CONNECTOR
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.09 0.11 0.14 0.18
0.11 0.13 0.18 0.22
0.12 0.14 0.19 0.24
0.14 0.17 0.22 0.28
0.18 0.22 0.29 0.36
0.21 0.25 0.34 0.42
- 0.28 0.38 0.48
- 0.32 0.43 0.54
- - 0.48 0.60
- - 0.53 0.66
- - 0.58 0.72
- - 0.63 0.78
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-2309
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
WC-WP 75 x 50
WC-WP 100 x 50
WC-WP 100 x 75
WC-WP 100 x 100
:
WC-WP 150 x 100
WC-WP 350 x 100
WC-WP 400 x 100
WC-WP 450 x 100
WC-WP 500 x 100
:
:
WC-WP 200 x 100
WC-WP 250 x 100
WC-WP 300 x 100
:
:
:
:
:
70
STEEL WIRE WAY
END CAP
1.0 mm. 1.2 mm. 1.6 mm. 2.0 mm.
0.06 0.07 0.10 0.12
0.11 0.13 0.18 0.22
0.12 0.14 0.19 0.24
0.14 0.17 0.22 0.28
0.18 0.22 0.29 0.36
0.21 0.25 0.34 0.42
- 0.28 0.38 0.48
- 0.32 0.43 0.54
- - 0.48 0.60
- - 0.53 0.66
- - 0.58 0.72
- - 0.63 0.78
Note :
STANDARD BS, NEMA, E.I.T
MATERIALS Cold Rolled Mild Steel Sheet
Hot Rolled Mild Steel Sheet
Galvanized Steel Sheet
Aluzinc Steel Sheet
Stainless Steel Sheet
FINISHING Painting by Electro-Static Spraying with Epoxy / Polyester
Powder Paint Coating 60-80 µM. ThicknessHot Dip Galvanized 65µM. Thickness to BS 729
TME-TDSWW-2409
TECHNICAL DATA OF CABLE TRAY SYSTEM
T
he c
onte
nts
an
d s
pecific
ations o
f th
is d
ata
shee
t are
subje
ct to
chan
ge w
itho
ut p
rior
no
tice. N
o p
art
of
this
da
ta m
ay b
e r
epro
duced w
itho
ut th
e p
rior
ap
pro
val of
Thai M
axw
ell
Ele
ctr
ic.
TYPEWEIGHT (kg.)
THICKNESS
(W x H)
EC-WP 75 x 50
EC-WP 100 x 50
EC-WP 100 x 75
EC-WP 100 x 100
:
EC-WP 150 x 100
EC-WP 200 x 100
EC-WP 250 x 100
EC-WP 300 x 100
EC-WP 350 x 100
EC-WP 400 x 100
:
:
:
:
EC-WP 450 x 100
EC-WP 500 x 100
:
:
:
71
MAX.
WORKING
PRESSURE
MOTOR
POWERNOISE LEVEL
DISCHARGE
PIPE SIZEWEIGHT
(kgf/cm²) (m³/min) (CFM) (kW/HP) dB(A) (inch) W L H (kg)
8 3.73 132
10 3.11 110
13 2.78 98
7.5 6.82 241
10 5.75 203
13 4.43 156
7.5 9.88 349
10 8.30 293
13 6.85 242
7.5 13.40 473
10 12 424
13 8.18 289
7.5 20.44 722
10 16.35 577
13 13.12 463
7.5 28.63 1011
10 23.55 831
13 20.57 726
7.5 43.78 1545
10 36.91 1303
13 29.96 1058
REMARK:
1 Power Supply 3 phase 380 V 50 Hz (all model)
TME-TDSA-0110
3200
FREE AIR DELIVERY
(FAD)
710
1200
2000
2200
2800
72
72
74
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
MODELCOOLING
SYSTEM
DIMENSION (mm.)
66
68
69
MX-37
4100
MX-110
TECHNICAL DATA OF SCREW AIR COMPRESSOR MX
MX-250
22/30
37/50
55/75
75/100
110/150
160/210
250/330
MX-22
75
MX-55
MX-75
MX-160
Air
Air
Air
Air
Air/Water
3
Air/Water
Air/Water 3400
1700
1800
1400
1700
1800
2100
3000
3000
1100
1100
1700
3
1 ½
2
2
3
15001 ¼
2000
900
1650
1720
1800
1900
1900
1000
72
WORKING
PRESSURE
MOTOR
POWERNOISE LEVEL
DISCHARGE
PIPE SIZEWEIGHT
(kgf/cm²) (m³/min) (CFM) (kW/HP) dB(A) (inch) W L H (kg)
8 1.39 49
8 1.85 65
10 1.37 48
MXE-15 8 2.65 94 15/20 72 Air 3/4 970 750 900 210
8 3.73 132
8 3 106
10 2.9 102
13 2.9 102
8 6 212
10 5.23 185
13 4.17 147
8 7.36 260
10 6 212
13 5.8 205
8 8.6 304
10 7.9 279
13 6.6 233
8 11.84 418
10 9.3 328
13 8.4 297
REMARK:
1 Power Supply 3 phase 380 V 50 Hz (all model)
TME-TDSA-0210
570
920
1050
1260
1600
74
74
74
1 ¼
2
TECHNICAL DATA OF SCREW AIR COMPRESSOR MXE
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
Air
Air
Air
Air
210
MXE-22
MXE-37
MXE-55
MXE-75
22/30
37/50
55/75
75/100
1500
1650
1720
1800
1650
1100
1100
1000
970 750
1400
1700
1800
2100
1700
2
900
COOLING
SYSTEMMODEL
DIMENSION (mm.)
MXE-11
FREE AIR DELIVERY
(FAD)
900
1000
MXE-45
11/15 71 Air 3/4
45/60 74 Air 1 ½
1 ½
72
73
Single Stage
CAPACITY Dia. x L
(kgf/cm²) (Litre/min) (CFM) (kW/HP) BORE x STROKE NO. (R.P.M.) (Litre) (mm.)
AC-202 7 340 12 1.5/2 65 x 51 2 1010 107 350 x 1080
AC-303 7 480 17 2.2/3 65 x 48 3 1010 128 350 x 1400
AC-303L 7 480 17 2.2/3 65 x 48 3 1010 160 390 x 1420
AC-503 7 770 27.1 3.7/5 80 x 60 3 850 160 390 x 1420
AC-503L 7 770 27.1 3.7/5 80 x 60 3 850 260 490 x 1480
AC-752 7 1045 37 5.6/7.5 100 x 70 2 950 260 490 x 1480
AC-752L 7 1045 37 5.6/7.5 100 x 70 2 950 317 490 x 1780
AC-1003 7 1485 52.3 7.5/10 100 x 70 3 900 317 490 x 1780
AC-1003L 7 1485 52.3 7.5/10 100 x 70 3 900 530 620 x 1800
AC-1503 7 2335 82.3 11/15 120 x 80 3 870 317 490 x 1780
AC-1503L 7 2335 82.3 11/15 120 x 80 3 870 530 620 x 1800
Two Stage
CAPACITY Dia. x L
(kgf/cm²) (Litre/min) (CFM) (kW/HP) BORE x STROKE NO. (R.P.M.) (Litre) (mm.)
HAC-303 12 303 10.7 2.2/3 L65 (H51) x 48 950 128 350 x 1400
HAC-303L 12 303 11 2.2/3 L65 (H51) x 48 950 160 390 x 1420
HAC-503 12 572 20.2 3.7/5 L80 (H65) x 60 950 160 390 x 1420
HAC-503L 12 572 20.2 3.7/5 L80 (H65) x 60 950 260 490 x 1480
HAC-1003 12 1088 38.5 7.5/10 L100 (H80) x 70 990 317 490 x 1780
HAC-1003L 12 1088 38.5 7.5/10 L100 (H80) x 70 990 530 620 x 1800
HAC-1503 12 1566 55 11/15 L120 (H100) x 80 860 317 490 x 1780
HAC-1503L 12 1566 55 11/15 L120 (H100) x 80 860 530 620 x 1800
REMARK:
1 Power Supply 3 phase 380 V 50 Hz (all model)
TME-TDPA-0110
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
MODEL
TECHNICAL DATA OF PISTON AIR COMPRESSOR
MODEL
AIR RECEIVER
Lx2, Hx1
COMPRESSORMOTOR
POWER
AIR RECEIVER
CYLINDER
CYLINDER COMPRESSOR
WORKING
PRESSUREDISPLACEMENT
DISPLACEMENTMOTOR
POWER
WORKING
PRESSURE
74
INLET AIR TEMPERATURE 10 80C
WORKING
PRESSURE
INLET-OUTLET
PIPE SIZE
(kgf/cm²) (m³/min) (CFM) (HP) REFRIGERANT (inch) W L H
MDH-008 7 0.85 30 1/2 R134a 3/4 450 750 735
MDH-012 7 1.2 42 1/2 R134a 1 450 800 790
MDH-018 7 1.8 64 3/4 R22 1 450 800 825
MDH-023 7 2.3 81 1 R22 1½ 480 1025 830
MDH-030 7 3.1 109 1½ R22 1½ 480 1070 1280
MDH-040 7 4 141 1¼ R22 1½ 480 1070 1280
MDH-055 7 5.5 194 1½ R22 2 480 1180 1320
INLET AIR TEMPERATURE 10 45C
WORKING
PRESSURE
INLET-OUTLET
PIPE SIZE
(kgf/cm²) (m³/min) (CFM) (HP) REFRIGERANT (inch) W L H
MDB-014 7 1.4 49 1/3 R134a 3/4 40 70 75
MDB-019 7 1.9 67 1/2 R134a 1 40 70 75
MDB-028 7 2.8 99 3/4 R134a 1 40 70 75
MDB-044 7 4.4 155 1 R22 1½ 55 80 100
MDB-070 7 7 247 1½ R22 1½ 55 80 100
MDB-106 7 10.6 374 2½ R22 2 65 120 110
MDB-145 7 14.5 512 3 R22 2 65 140 120
MDB- 210 7 21 741 4 R22 2½ 65 160 120
MDB-270 7 27 953 5 R22 2½ 80 160 140
MDB-325 7 32.5 1147 6½ R22 3 80 160 140
REMARK:
1. Ambient temperature 10 ~ 40°C
TME-TDPA-0110
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
1 phase, 50Hz,
220 V
POWER SUPPLY
1 phase, 50Hz,
220 V
3 phase, 50Hz,
220 V(380 V)
COMPRESSOR
TECHNICAL DATA OF REFRIGERATED COMPRESSOR AIR DRYER
POWER SUPPLYCOMPRESSOR
MODELCAPACITY DIMENSION (mm.)
DIMENSION (mm.)MODEL
CAPACITY
75
WORKING PRESSURE INLET-OUTLET PIPE SIZE
(kgf/cm²) (Litre/min) (m³/min) (scfm) (inch)
MXH-006 7 610 0.6 22 1/2
MXH-008 7 820 0.6 29 1/2
MXH-012 7 1250 1.3 44 3/4
MXH-024 7 2440 2.4 86 1
MXH-035 7 3530 3.5 125 1
MXH-042 7 4280 4.3 151 1½
MXH-060 7 6540 6.5 231 1½
MXH-074 7 7430 7.4 262 1½
MXH-090 7 9560 9.6 337 2
MXH-140 7 14320 14.3 505 2
REMARK:
1. Max Working Pressure 10 kgf/cm²
TME-TDDA-0110
CAPACITY AT 7 kgf/cm²
TECHNICAL DATA OF COMPRESSED AIR FILTER
MODEL
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
76
CAPACITY Dia. x L
(kgf/cm²) (Litre/min) (CFM) (HP) (R.P.M.) (Litre) (mm.)
DC 12-5 8 112 3.95 2 1 2500 10 130 x 360
PK-30-10 8 201 7.10 3 1 2900 10 180 x 520
PK-30-12 8 201 7.10 3 1 2900 12 200 x 480
PK-30-25 8 201 7.10 3 1 2900 25 244 x 560
VD-40-40 8 290 10.25 4 2 1440 40 260 x 740
VD-40-80 8 290 10.25 4 2 1440 80 360 x 850
VD-50-40 8 422 14.91 5 2 2900 40 260 x 740
VD-40V 8 290 10.25 4 2 1440 65 390 x 560
VD-50F 8 422 14.91 5 2 2900 20 240 x 520
EG-30F 8 250 8.83 5.5 1 3400 32 152 x 480 x 2
PT03-55T 8 525 18.55 5.5 3 1100 64 152 x 1000 x 2
HPT03-55T 14 250 8.83 5.5 3 1100 64 152 x 1000 x 2
STANDARD ACCESSORIES:
- Pressure switch (all model)
- Regulator gauge (excepted HPT03-55T Model)
- Pressure gauge (all model)
- Safety valve (all model)
- Coupler ( x 2 for VD-40V, VD-50F, EG-30F, PT03-55T and HPT03-55T Model)
REMARK:
1. Power Supply for Model DC 12-5 is 12V Car Battery
2. Power Supply for Model EG-30F, PT03-55T and HPT03-55T is Gasoline
3. Power Supply for other Model except remark 1 and 2 is single phase 220V 50HZ
TME-TDPA-0110
NO. OF
CYLINDER
MOTOR
POWERDISPLACEMENT
WORKING
PRESSURE
The c
onte
nts
and s
pecific
ations o
f th
is d
ata
sheet
are
subje
ct
to c
hange w
ithout
prior
notice.
No p
art
of
this
data
may b
e r
epro
duced w
ithout
the p
rior
appro
val of
Thai M
axw
ell
Ele
ctr
ic.
AIR RECEIVER
TECHNICAL DATA OF PORTABLE DIRECT DRIVE AIR COMPRESSOR
MODELCOMPRESSOR
77