iso/iec 17025:2017 accreditation #103104lidocane.pdf · iso/iec 17025:2017 accreditation #103104...

5
Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification CERTIFICATE OF ANALYSIS ISO/IEC 17025:2017 ACCREDITATION #103104 Order #: 57033 Order Name: CBD 500 Roll-on w/Lidocaine Batch#: 00236B Received: 07/01/2020 Completed: 07/29/2020 Sample N/D D9-THC 0.600% Total CBD 510.3 mg Cannabinoids per unit 510.3 mg CBD per unit 1 unit = 85.05 grams per unit x Cannabinoid concentration Cannabinoids Test SHIMADZU INTEGRATED UPLC-PDA GSL SOP 400 PREPARED: 07/27/2020 17:57:05 Cannabinoids LOQ weight(%) mg/g mg/unit D9-THC 10 PPM N/D N/D N/D THCA 10 PPM N/D N/D N/D CBD 10 PPM 0.600% 6.000 510.3 CBDA 20 PPM N/D N/D N/D CBDV 20 PPM N/D N/D N/D CBC 10 PPM N/D N/D N/D CBN 10 PPM N/D N/D N/D CBG 10 PPM N/D N/D N/D CBGA 20 PPM N/D N/D N/D D8-THC 10 PPM N/D N/D N/D THCV 10 PPM N/D N/D N/D TOTAL D9-THC N/D N/D N/D TOTAL CBD* 0.600% 6.000 510.3 TOTAL CANNABINOIDS 0.600% 6.000 510.3 Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director Green Scientific Labs [email protected] 1-833 TEST CBD Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data was reported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation that may result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it was taken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results with the original client of record.

Upload: others

Post on 23-Oct-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

  • Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification

    CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 57033Order Name: CBD 500 Roll-onw/LidocaineBatch#: 00236BReceived: 07/01/2020Completed: 07/29/2020

    Sample

    N/D D9-THC

    0.600% Total CBD

    510.3 mg Cannabinoids per

    unit

    510.3 mg CBD per

    unit

    1 unit = 85.05 grams per unit x Cannabinoidconcentration

    Cannabinoids TestSHIMADZU INTEGRATED UPLC-PDAGSL SOP 400 PREPARED: 07/27/2020 17:57:05 Cannabinoids LOQ weight(%) mg/g mg/unitD9-THC 10 PPM N/D N/D N/DTHCA 10 PPM N/D N/D N/DCBD 10 PPM 0.600% 6.000 510.3CBDA 20 PPM N/D N/D N/DCBDV 20 PPM N/D N/D N/DCBC 10 PPM N/D N/D N/DCBN 10 PPM N/D N/D N/DCBG 10 PPM N/D N/D N/DCBGA 20 PPM N/D N/D N/DD8-THC 10 PPM N/D N/D N/DTHCV 10 PPM N/D N/D N/D

    TOTAL D9-THC N/D N/D N/DTOTAL CBD* 0.600% 6.000 510.3TOTAL CANNABINOIDS 0.600% 6.000 510.3

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • PESTICIDE ANALYSIS:GSL SOP 401 PREPARED: 07/01/2020 18:10:12

    N/D = Not Detected, A/LOQ = Above LOQ Level, B/LOQ = Below LOQ Level, B/LOD = Below LOD Level

    CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 57033Order Name: CBD 500 Roll-onw/LidocaineBatch#: 00236BReceived: 07/01/2020Completed: 07/29/2020

    GCMS-MS - Shimadzu GCMS-TQ8040

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    CAPTAN 0.700 N/D 0.003 0.001CHLORDANE 0.100 N/D 0.003 0.001CHLORFENAPYR 0.100 N/D 0.003 0.001COUMAPHOS 0.100 N/D 0.003 0.001

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    CYFLUTHRIN 2.000 N/D 0.003 0.001CYPERMETHRIN 1.000 N/D 0.003 0.001PARATHION-METHYL 0.100 N/D 0.003 0.001PENTACHLORONITROBENZENE 0.100 N/D 0.003 0.001

    LCMS-MS - Shimadzu LCMS-8060

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    ABAMECTIN B1A 0.100 N/D 0.005 0.001ACEPHATE 0.100 N/D 0.001 0.001ACEQUINOCYL 0.100 N/D 0.001 0.001ACETAMIPRID 0.100 N/D 0.005 0.001ALDICARB 0.100 N/D 0.005 0.001AZOXYSTROBIN 0.100 N/D 0.001 0.001BIFENAZATE 0.100 N/D 0.005 0.001BIFENTHRIN 3.000 N/D 0.005 0.001BOSCALID 0.100 N/D 0.005 0.001CARBARYL 0.500 N/D 0.003 0.001CARBOFURAN 0.100 N/D 0.001 0.001CHLORANTRANILIPROLE 10.000 N/D 0.005 0.005CHLORPYRIFOS 0.100 N/D 0.001 0.001CLOFENTEZINE 0.100 N/D 0.001 0.001DAMINOZIDE 0.100 N/D 0.005 0.001DIAZINON 0.100 N/D 0.001 0.001DICHLORVOS 0.100 N/D 0.005 0.001DIMETHOATE 0.100 N/D 0.001 0.001DIMETHOMORPH 2.000 N/D 0.005 0.001ETHOPROPHOS 0.100 N/D 0.001 0.001ETOFENPROX 0.100 N/D 0.001 0.001ETOXAZOLE 0.100 N/D 0.010 0.005FENHEXAMID 0.100 N/D 0.005 0.001FENOXYCARB 0.100 N/D 0.005 0.001FENPYROXIMATE 0.100 N/D 0.001 0.001FIPRONIL 0.100 N/D 0.003 0.001FLONICAMID 0.100 N/D 0.025 0.010FLUDIOXONIL 0.100 N/D 0.003 0.001HEXYTHIAZOX 0.100 N/D 0.005 0.001

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    IMAZALIL 0.100 N/D 0.005 0.001IMIDACLOPRID 5.000 N/D 0.005 0.001KRESOXIM-METHYL 0.100 N/D 0.010 0.005MALATHION 0.500 N/D 0.005 0.001METALAXYL 2.000 N/D 0.001 0.001METHIOCARB 0.100 N/D 0.005 0.001METHOMYL 1.000 N/D 0.001 0.001MEVINPHOS 0.100 N/D 0.001 0.001MYCLOBUTANIL 0.100 N/D 0.005 0.001NALED 0.100 N/D 0.005 0.001OXAMYL 0.500 N/D 0.001 0.001PACLOBUTRAZOL 0.100 N/D 0.005 0.001PERMETHRINS 0.500 N/D 0.005 0.001PHOSMET 0.100 N/D 0.005 0.001PIPERONYLBUTOXIDE

    3.000 N/D 0.001 0.001

    PRALLETHRIN 0.100 N/D 0.005 0.005PROPICONAZOLE 0.100 N/D 0.010 0.005PROPOXUR 0.100 N/D 0.001 0.001PYRETHRINS(PYRETHRIN I)

    0.500 N/D 0.005 0.005

    PYRIDABEN 0.100 N/D 0.005 0.001SPINETORAM 0.100 N/D 0.001 0.001SPIROMESIFEN 0.100 N/D 0.005 0.001SPIROTETRAMAT 0.100 N/D 0.001 0.001SPIROXAMINE 0.100 N/D 0.001 0.001TEBUCONAZOLE 0.100 N/D 0.005 0.001THIACLOPRID 0.100 N/D 0.001 0.001THIAMETHOXAM 5.000 N/D 0.001 0.001TRIFLOXYSTROBIN 0.100 N/D 0.001 0.001

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 57033Order Name: CBD 500 Roll-onw/LidocaineBatch#: 00236BReceived: 07/01/2020Completed: 07/29/2020

    RESIDUAL SOLVENTS:Headspace GCMS - Shimadzu GCMS QP2020 with HS20

    GSL SOP 405Prepared: 07/06/2020 18:24:09

    Residual Solvent Action Level (ppm) Results (ppm) LOQ (ppm) LOD (ppm)1,1-DICHLOROETHENE 8 N/D 0.63 0.631,2- DICHLOROETHANE 2 N/D 0.12 0.02ACETONE 5,000 N/D 140 20ACETONITRILE 410 N/D 25 1BENZENE 1 N/D 1 0.5BUTANE 5,000 N/D 50 10CHLOROFORM 1 N/D 1 0.5CIS 1,2-DICHLOROETHENE 5 N/D 0.73 0.18ETHYL ACETATE 5,000 N/D 140 20ETHYL ETHER 5,000 N/D 140 20ETHYLENE OXIDE 1 N/D 0 0ISOPROPYL ALCOHOL 5,000 N/D 140 20METHANOL 3,000 N/D 100 20METHYLENE CHLORIDE 125 N/D 0.15 0.15N-HEPTANE 5,000 N/D 140 20N-HEXANE 290 N/D 18 10PENTANE 5,000 N/D 140 20PROPANE 5,000 N/D 20 1TOLUENE 890 N/D 53 1TRANS 1,2-DICHLOROETHENE 5 N/D 0.73 0.18TRICHLOROETHENE 1 N/D 1 0.5XYLENES 150 N/D 130 20

    NotesEthanol as part of ingredients

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 57033Order Name: CBD 500 Roll-onw/LidocaineBatch#: 00236BReceived: 07/01/2020Completed: 07/29/2020

    Microbial Analysis:PCR - Agilent AriaMX

    Microbial Analysis GSL SOP 406 Uploaded: 07/08/2020 18:58:30

    Test Test MethodUsed Device Used LOD Allowable CriteriaActualResult Pass/Fail

    STEC E.COLI* USP 61/62† ARIAMX PCR 1 CFU/G** DETECT/NOT DETECTEDNOT

    DETECTEDPASS

    SALMONELLA* USP 61/62† ARIAMX PCR 1 CFU/G** DETECT/NOT DETECTEDNOT

    DETECTEDPASS

    YEAST AND MOLD USP 61/62† ARIAMX PCR CFU/G BY SAMPLE TYPE** 10,000 CFU/GNOT

    DETECTEDPASS

    TOTAL AEROBIC BACTERIA USP 61/62† ARIAMX PCR CFU/G BY SAMPLE TYPE** 100,000 CFU/GNOT

    DETECTEDPASS

    COLIFORM USP 61/62† ARIAMX PCR CFU/G BY SAMPLE TYPE** 1,000 CFU/GNOT

    DETECTEDPASS

    ENTEROBACTERIACEAE USP 61/62† ARIAMX PCR CFU/G BY SAMPLE TYPE** 1,000 CFU/GNOT

    DETECTEDPASS

    † USP 61 (enumeration of bacteria TAC, TYM, and ENT/Coliform), USP 62 (identifying specific species E.coli Aspergillus etc) * STEC and Salmonella run as Multiplex ** CFU/g Calculation based on Select Category Type Gummy MIP/Extract Flower matrix

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 57033Order Name: CBD 500 Roll-onw/LidocaineBatch#: 00236BReceived: 07/01/2020Completed: 07/29/2020

    Mycotoxin Analysis:LC-MS - Shimadzu LCMS-8060GSL SOP 401 Uploaded: 07/02/2020 16:20:16

    Analyte Action Lvl (ppb) Results (ppb)AFLATOXIN B1 20 N/DAFLATOXIN B2 20 N/DAFLATOXIN G1 20 N/DAFLATOXIN G2 20 N/DOCHRATOXIN A 20 N/D

    LOQ is 1ppb, LOD is 1ppb

    Heavy Metals Analysis:ICP-MS - Shimadzu ICPMS-2030GSL SOP 403 Uploaded: 07/06/2020 15:23:41

    Metal Action Level (ppb) Result (ppb)ARSENIC (AS) 200 B/LOQCADMIUM (CD) 200 B/LOQMERCURY (HG) 100 B/LOQLEAD (PB) 500 B/LOQ

    Lower Limit of Quantitation (LOQ) is 75 ppb

    Water Activity:HD-3A Water Activity Meter - GSL SOP 407 Uploaded: 07/15/2020 13:35:43

    Water0.90

    Filth and Foreign Materials Analysis:Microscope - Amscope Simul-Focal Trinocular Stereo Zoom Microscope - GSL SOP 409 Uploaded: 07/07/2020 17:43:25

    Pass: No Foreign Materials Detected

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.