34 ISOKINETIC SOURCE SAMPLING EQUIPMENT 800-882-3214 / 919-557-7300 www.apexinst.com BASIC-PLUS METHOD 5 For a source sampling company to get started sampling for particulates (U.S. EPA Reference Method 5), Apex recommends a combination of equipment that can be configured for both rigid and flexible set-ups. Select your METER CONSOLE (see page 8-10) Select your SAMPLE PUMP (see page 12 - 13) SK-M5BP SK-M5BP-V Basic Method 5 Includes: • Stainless Steel Nozzle Set • 6-ft Probe with Heater • 1 Stainless Steel Probe Liner, 3 Glass Probe Liners • 30-ft Split U-Cord • 15-ft Unheated Sample Line • Hot & Cold Box Assembly with Riser • Sample Frame for Cold Box (Flexible Config.) • Strain Reliefs • Basic Glassware Set (1 sample run configuration) • Filter Paper • Brushes (Probe & Nozzle) • Calculator (programmed for Method 5) DELUXE-PLUS METHOD 5 The professional source sampling company must be prepared for a wide variety of con- ditions and locations. Apex recommends the “Deluxe Plus” system, which can be used in both rigid and flexible configurations. Even with the classic rigid arrangement, the ad- ditional glassware allows you to have pre-measured and filled impingers, pre-weighed filter assemblies, and minimum turnaround time between runs. The flexible arrange- ment is effective for challenging environments like vertical traverses and space-limited sources. After selection of a meter console and external sample pump, the Deluxe-Plus system provides all of the components listed in the above Basic-Plus system. Schematic of Method 5 Flexible Sampling Train Schematic of Method 5 Rigid Sampling Train PLUS: • Glass Nozzle Set • 3-ft & 9-ft Probe Assemblies with • Stainless Steel & Glass Probe Liners • 60-ft Split U-Cord • 2.5 Sets of Glassware Plus Carrying Case • 4 Monorail Assemblies (9-ft & 12-ft) • Transport Case for a Meter Console • Calibrated Orifice Set SK-M5DP SK-M5DP-V

Upload: roque-hernandez

Post on 29-Nov-2015

105 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Isokinetic Part 1 Catalog 1-01-12 NP

34

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

BASIC-PLUS METhOd 5For a source sampling company to get started sampling for particulates (U.S. EPA Reference Method 5), Apex recommends a combination of equipment that can be configured for both rigid and flexible set-ups.Select your METER CONSOLE (see page 8-10)Select your SAMPLE PUMP (see page 12 - 13)

sk-m5Bp

sk-m5Bp-V

Basic Method 5 Includes:• Stainless Steel Nozzle Set• 6-ft Probe with Heater• 1 Stainless Steel Probe Liner, 3 Glass Probe Liners• 30-ft Split U-Cord• 15-ft Unheated Sample Line• Hot & Cold Box Assembly with Riser• Sample Frame for Cold Box (Flexible Config.)• Strain Reliefs• Basic Glassware Set (1 sample run configuration)• Filter Paper• Brushes (Probe & Nozzle)• Calculator (programmed for Method 5)

dELUXE-PLUS METhOd 5The professional source sampling company must be prepared for a wide variety of con-ditions and locations. Apex recommends the “Deluxe Plus” system, which can be used in both rigid and flexible configurations. Even with the classic rigid arrangement, the ad-ditional glassware allows you to have pre-measured and filled impingers, pre-weighed filter assemblies, and minimum turnaround time between runs. The flexible arrange-ment is effective for challenging environments like vertical traverses and space-limited sources. After selection of a meter console and external sample pump, the Deluxe-Plus system provides all of the components listed in the above Basic-Plus system.

Schematic of Method 5 Flexible Sampling Train

Schematic of Method 5 Rigid Sampling Train

PLUS:• Glass Nozzle Set• 3-ft & 9-ft Probe Assemblies with • Stainless Steel & Glass Probe Liners• 60-ft Split U-Cord• 2.5 Sets of Glassware Plus Carrying Case• 4 Monorail Assemblies (9-ft & 12-ft)• Transport Case for a Meter Console• Calibrated Orifice Set

sk-m5dp

sk-m5dp-V

Page 2: Isokinetic Part 1 Catalog 1-01-12 NP

35

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

COMPACT METhOd 5The Apex Compact Method 5 Sampler Kit features an independently Heated Stainless Steel Filter Assembly (SFA-82H) that connects directly to a standard Method 5 probe. It does not require a separate heated filter compartment, and utilizes a flexible sample line, and a split umbilical cord with power adapter, to allow sampling in space-limited areas. The standard glass impingers have been replaced with Stainless Steel Impingers (S-5CN) to eliminate glass breakage. Three filter assemblies are recommended to speed up the turn around time between consecutive runs. Add “V” to end of part number for 240V option at no additional cost.

sk-Cm5

sk-Cm5-V

STAINLESS STEEL hEATEd FILTER ASSEMBLYThe Apex Instruments Heated Stainless Filter Assembly (SFA-82H) is for sampling particulates from space-limited industrial sources. The filter assembly has a two piece threaded clamping ring with an integral 300 watt ring heater . A Viton® O-Ring seals the 82.6 mm filter and prevents sample bypass. It has stainless steel inlet, outlet and a PTFE filter support screen (GA-3T). The inlet plate comes with a 5/8” tube union for swaging directly to a plain probe liner. The outlet plate has 3/8” female NPT connection and a male 3/8” full flow quick connect. The mating female quick connects with the thermocouple, which is supplied with the Unheated Sample Line (USL-�-QST) or SFA-82-QCF6, may be ordered separately. There is a thermal insulated blanket supplied with each unit. An unheated version is also available without the integral heater and blanket. Add “V” to end of part number for 240V at no extra cost.

SFA-82 (unheated)sFa-82hsFa-82hVsFa-82-qCF6sFa-82-Bkt

SFA-82hDepending upon the source, it may be possible to combine

Method 5 and Method 8 into the same train.

SK-CM5 Kit• Heated Filter Assemblies (3)• Probe Sheath with Heater • Stainless Steel Probe Liner• Impinger Box • Impinger Inlet Strain Relief• 60’ Split Umbilical Cord• Unheated Sample Line with Stainless Steel Overbraid• Power Box Adapter • Umbillical Adapter • Stainless Steel Nozzle Set• Stainless Steel Impinger Assembly• PTFE Coated Glass Fiber Filters

Schematic of U.S. EPA Method 5 Compact Sampling Train

SFA-82-QCF6

SFA-82-BKT

Page 3: Isokinetic Part 1 Catalog 1-01-12 NP

36

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

METhOd 5GMethod 5G Determination of Particulate Matter Emissions from Wood Heaters (Dilution Tunnel Sampling Location). The exhaust from a wood heater is collected with a total collection hood, and is combined with ambient dilution air. Particulate matter is withdrawn proportionally from a single point in a sampling tunnel and is collected on two glass fiber filters in series.

gnFa-4-5g

Components Include:4” Filter Assembly, Unground Glass #28 Ball/Socket, Poly Donut Spacer with ThermocoupleAssembly, Dual PTFE Filter Supports and Open Style Aluminum Clamp.

METhOd 5I The METHOD 5I SAMPLING KIT is similar to Basic Method 5, except for the addition of the 5I Holder (SGFA-47-5I) and is designed for the determination of low-level particulate matter (PM) emissions from stationary sources. Method 5I is most effective for PM catches less than 50 mg and is valid for performing correlation of manual PM measurements to PM con-tinuous emission monitors or determining PM emissions from low-level sources such as turbines. Add “V” to end of part number for 240V at no extra cost. After selecting a Method 5 Meter Console and an external sample pump in conjunction with a Method 5 kit, add a Method 5I Holder.

The 5I Filter Holder inlet is constructed of Borosilicate Glass to hold a 47mm glass fiber filter with a wafer-thin stainless steel filter support and a Viton® O-Ring. The assembly is wrapped with PTFE tape for weighing, averaging less than 35 grams, providing a positive seal against leakage. Method 5I 47mm Filter Assembly with Glass Inlet & SS Outlet, with 2 45 deg bends.

ALTERNATE METhOd 5I FILTER ASSEMBLY (Straight) Same Application as Method 5IStraight version of SGFA-47-5I, for use with SB-2M-ST, straight through heated filter box.

sgFa-47-5is

SGFA-47-5IS

SGFA-47-5I

GNFA-4-5G

Page 4: Isokinetic Part 1 Catalog 1-01-12 NP

37

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

Controlled Condensate is an alternative to EPA Method 8 for determining sulfuric acid emissions. Sulfuric acid vapor or mist and the sulfur dioxide are separated, by controlling the condensation based on difference in dew points, and both fractions are measured separately by the barium-thorin titration method. Controlled condensation method is the primary sampling and analytical tool for quantifying sulfuric acid emissions from stationary sources. The method is based upon the selective condensation of sulfuric acid from a gas stream by means of a water cooled condenser. The major advantage of the condensation method is that it provides reliable reproducible SO3 and SO2 values with minimal interference from high SO2 concentrations. There are several versions of the method. Option “V” is added for 240V.

sk-CC

sk-CC-V

METhOd 8

Method 8 Sampling Kit

Part Description

SB-8 Sample Frame with Probe Clamp

UA-3J Power Box Adapter

GNFA-2U 2” Filter Assembly,Unground Glass with 90° Inlet and Outlet,Open Style Alum Clamp

METhOd 8 RECOMMENdEdACCESSORIES

CONTROLLEd CONdENSATEConditional Test Method CTM-13

Quartz Liner Available

Glass Liner

GFA-2590#-CC SB-2M-STCC

Sampling Kit Available

The Method 8 Sampling Kit is used with either the XC-522 or XC-572 Meter Console and an external sample pump for the determination of sulfuric acid mist and sulfur dioxide emissions from stationary sources. U.S. EPA Reference Method 8 was originally developed to test emissions from sulfuric acid plants but has been adapted to sample emis-sions from sulfur dioxide sources. Call for details on Flex-ible Arrangements. Add “V” to end of part number for 240V at no extra cost.

Schematic of EPA Method 8 Sampling Train

UA-3J

GA-100

SB-3SB-8

PS- H PLN- GGlass Lined Probe

Glass NozzleNG-

US- -10

Page 5: Isokinetic Part 1 Catalog 1-01-12 NP

38

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

Schematic of EPA Method 17 Flexible Sampling Train

Schematic of U.S. EPA Method 17 Rigid Sampling Train

In Method 7C and 7d an integrated sample is passed through a series of full-size orifice impingers that contain an alkaline-potassium permanganate solution. The sample rate is between 400 and 500 cc per minute, normally three one hour samples are collected per test. The MC-623 is the console of choice, however, a low flow orifice adapter is offered for converting the XC-572 Method 5 source sampler console for low flow sampling. The Method 7C sample is analyzed colorimetrically and for Method 7D analysis is by ion chromatography. Please inquire for additional details. Add “V” for 220VAC option.

Ck-m7Cd

METhOd 7C and 7d

Model descriptionPC10-3G 3 ft CEM Probe Assembly, 5/8” Glass liner, 110 VAC

PLN-3G 3 ft Glass Probe liner, 5/8” OD with unground #28 grooved ball

GN-8 Double”L” Adapter, #28 unground sockets

GN-11 U-Tube, #28 unground sockets

GN-9AO-M7 Impinger Assembly, Stem with Orifice, 250 mL, unground O-ring joints

Method 7 Accessories

PC10-3G

GN-9AO-M7GN-9A

SB-3

GN-8GN-11

SB-8

Method 17 Sampling Kit Components Include:• In-stack Filter Assembly

• Glass Fiber Thimbles

• Method 5 Probe Sheath with Tube Heater

• Method 17 Probe Liner w/ 3/8” Full Flow Male Quick Connects

• Unheated Sample Line with PFA Over braid

• 30’ Split Umbilical Line

• Power Box Adapter

• Sample Case Adapter

• Impinger Inlet Strain Relief

• Impinger Box, Insulated Coolant Reservoir

• Stainless Steel Nozzle Set

• Stainless Steel Impinger Assembly

sk-m17psk-m17p-V

METhOd 17 PLUS (RIGId & FLEXIBLE)The Apex Instruments Method 17 Sampling Kit is a convenient package for sampling particulate matter. Multiple fitting arrangements and filter assemblies are available with an in-stack filter. Add “V” to end of part number for 240V at no extra cost.

GN-9A Impinger Assembly, Plain Stem, 500 mL, unground O-ring joints, modified Greenburg-Smith

GA-100 Umbilical Adapter (Gooseneck) , #28 Socket with thermocouple, mounting bracket, 1/2” Male quick connects

SB-3 Impinger Box/Insulated Coolant Reservoir Model 100, holds 4 impingers

SB-8 Modular Sample Frame with Probe Clamp and Impinger Box Slides

Page 6: Isokinetic Part 1 Catalog 1-01-12 NP

39

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

SFA-4(Nozzles not included)

INTEGRATEd IN-STACK FILTER ASSEMBLY KIT The SGFA-47NK In-Stack Filter assembly kit features the unique design combination of borosilicate glass 47mm filter inlet with integrated nozzle, allowing the option to weigh the glass fiber filter media individually for Method 17 or very similar to Method 5I by weighing the combined nozzle, filter media with a support, O-Ring and PTFE Tape. The kit includes the standard array of seven nozzle sizes from 1/8” to 1/2”.

sgFa-47nk

METhOd 17 IN-STACK FILTER ASSEMBLIES

GLASS IN-STACK FILTER ASSEMBLIESThe Apex Instruments GFA-2590 Thimble Holder is constructed completely from borosilicate glass for use with Conditional Method for Ammonia (CTM-027) and accepts tapered 25 x 90mm thimbles, specifically manufactured for stack sampling. Does not require O-Rings, for testing at higher temperatures. The borosilicate glass withstands temperatures up to 480°C (900°F).

Nozzle Insert - Replace � with nozzle diameter. (Sizes 4-16). Call for additional sizesGFA-2590N�

Filter Body - 5/8” Glass Filter BodygFa-2590B

Metal Taper Joint Clamp - A durable nickel plated steel clip that securely holds the conical joint under pressure to withstand temperatures of up to 500°C (932°F).ktm-29

In-Stack Filter Assembly using a 47 mm diameter Filter Element.sFa-47

In-Stack Filter Assembly using 19mm x 90 mm Thimble Filter Element.sFa-190In-Stack Filter Assembly using 30mm x 100 mm Thimble Filter Element.sFa-300

In-Stack Filter Assembly using 25mm x 90mm Thimble Filter Element.sFa-2590

Inconel Version sFa-47inCo

Filter Inlet 47 mm Glass Filter Inlet with Integrated Nozzle. Replace � with nozzle diameter.

Part descriptionO-128V Viton® O-Ring for SFA-2590 (450 °F)

O-324S Silicone O-Ring for SFA-300 (500 °F)

O-324G Graphite O-Ring for SFA-300 (1000 °F)

O-324V Viton® O-Ring for SFA-300 (500 °F)

Q4213 Viton® Quad Ring for SFA-190 (450 °F)

O-223V Viton® O-Ring, 47 mm for SFA-47 (450 °F)

O-223H High Temperature Stainless Steel O-Ring for SFA -47

SF-TT20 PTFE Thrust Ring for SFA-47 Filter Assembly

O-324G Graphite O-Ring for SFA-300 (1000+ °F)

Replacement Seals

Filters and Thimbles, page 46

GFA-2590K In-Stack Thimble holder Kit - Includes a selection of the seven most commonly used nozzle inserts from 1/8” to 1/2” and one housing. Kit is conveniently packaged in a foam-lined carrying case for protection. The thimble holder connects directly to the end of the probe with a 5/8” tube union.gFa-2590k

Nozzle Size

GFA-2590N □ Nozzle Insert GFA-2590B

Filter Body

5/8” ShankKTM-29 CLIP

Product Glass Filter Inlet Integrated Nozzles

G-47N-ST 47 mm Glass Filter Inlet with ground #28 Socket on inlet

G-47N-4 47mm, with Attached Nozzle, Nozzle I.D. 1/8”

G-47N-5 47mm, with Attached Nozzle, Nozzle I.D. 5/32”

G-47N-6 47mm, with Attached Nozzle, Nozzle I.D. 3/16”

G-47N-7 47mm, with Attached Nozzle, Nozzle I.D. 7/32”

G-47N-8 47mm, with Attached Nozzle, Nozzle I.D. 1/4”

G-47N-10 47mm, with Attached Nozzle, Nozzle I.D. 5/16”

G-47N-12 47mm, with Attached Nozzle, Nozzle I.D. 3/8”

G-47N-14 47mm, with Attached Nozzle, Nozzle I.D. 7/16”

G-47N-16 47mm, with Attached Nozzle, Nozzle I.D. 1/2”

Call for Pricing of Quartz Components

Page 7: Isokinetic Part 1 Catalog 1-01-12 NP

40

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

Schematic of Method 23Sampling Train

METhOd 23 dELUXE PLUSThe Apex Instruments Method 23 (Modified Method 5) Source Sampler Kit is utilized for Method 23 determination of dioxins and furans (D/F’s) and/or Method 0010 Determination of Semi-Volatile Organic Compounds. The sampling train is identical to the standard Method 5 system with the addition of a water-cooled glass condenser and an XAD absorbent module followed by a knockout impinger. Additional glassware configurations are available. Please call for information.

Select Meter Console and External Pump for M23 then add a kit. Add “V” to part number for 240V option at an additional cost.

sk-m23dp

sk-m23dp-V

Product Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

MM5-P Submersible Coolant Pump, 120V

GNM-T XAD Trap, #28 Ball & Socket Joints, Unground

GN-16 Glass Cap #28 Socket, Unground, to Seal XAD Trap

GN-17 Glass Plug #28 Ball, Unground, to Seal XAD Trap

KBS-29 Clip, Knock, Plastic out Impinger, Unground

TL-7/5 Latex Tubing, 7/16 OD, 5/16 ID, Natural Color, Per Foot

Method 23 Individual Accessories

Product description

GNM-HC Horizontal Condenser, #28 Unground Sockets, Water Jacket, Hose Barbs

GNM-VC Vertical Condenser, #28 Unground Sockets, Water Jacket Hose Barbs

GNM-T XAD Trap, #28 Unground Socket nd O-Ring Ball (Top), Water, Jacket Hose Barbs

GN-9AKS Knock-Out Impinger Assembly, Unground (for Horizontal MM5)

Method 23 Glassware

Requirements:• Borosilicate Glass or Quartz Nozzles and Probe Liners are recommended.• Wrap XAD sorbent module with aluminum foil to shield from radiant heat and ultraviolet rays that dechlorinate the D/F isomers.• Sealing greases are not allowed. FEP O-Ring seals are recommended and may be required by some agencies.• Flexible train requires heated flexible sample lines.

Coolant Pump OptionsProduct Description

MM5-P Submersible Coolant Pump, 110V

MM5-PM Mini Submersible Coolant Pump, 110V

MM5-P220 Submersible Coolant Pump, 220V

MM5-P MM5-PM

M23 Sampling Train

Method 23 Source Sampler Kit Components:• 6’ Probe with Heater• Glass Probe Liners (3)• Glass Nozzle Set• Hot/Cold Box/Riser• 30’ Split-Back Umbilical • Glassware, Deluxe Set

• Horizontal Condensers (2)• XAD Traps (8)• Submersible Recirculating Pump• Probe and Nozzle Brushes• Programmed Calculator

Page 8: Isokinetic Part 1 Catalog 1-01-12 NP

41

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

METhOd 26A – hCl

M26A Sampling Train

The Apex Instruments Method 26A Sampling Train is used for determination of hydrogen halide and halogen emis-sions. Method 26A is the isokinetic alternative to Method 26. This method is particularly suited for sampling sources controlled by wet scrubbers emitting acid particulate matter. The method requires a Method 5 sampling train with the use of additional impingers, reagents and PTFE coated glass fiber filter media. Please call for more information. Add “V” to end of part number for 240V at no additional cost.

Product Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

NBT-1/2 Nozzle Brush, 1/2” diameter, PTFE Bristles

PBX-10T 10 foot Flexible PTFE Probe Brush Extension, Brush not Included

PBT-5/8 PTFE Probe Brush Tip (PTFE Barrel and Bristles), 5/8 inch Bristle Diameter

GN-9AK Knock-Out Impinger, Short Stem, 500ml, Unground O-Ring Joints

GN-9AO Impinger Assembly, Stem with Orifice & Plate, 500ml, Unground O-Ring Joints, Greenburg-Smith

GF-3TPG 82mm PTFE Coated Glass Fiber Filters - Hydrophobic, Low absorption of acid gases such as SOX or NOX . 50/box (MFS PG60)

Method 26A Recommended Accessories

Schematic of Method 26A Sampling Train

When stack temperatures exceed 210oC (410oF) a one-piece glass nozzle/liner assembly is recommended.

Page 9: Isokinetic Part 1 Catalog 1-01-12 NP

42

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

The METHOD 29 determination of metal emissions from hazardous waste incinerators involves a modification of the Method 5 train. The sampling train is the same as a Method 5 particulate train with the addition of up to three impingers to enhance the collection of metals of interest. The impinger train requires the SB-4 impinger case, glass nozzles, probe liners and non-metallic union. The method has been validated for the collection of 17 different metals.

Add “V” to end of part number for 240V option at no additional cost.

METhOd 29 – MULTIPLE METALS

Schematic of Method 29 Sampling Train

The standard glass filters are replaced with low background quartz filters. The impinger solutions are specific for different metals. Recovered samples are digested and appropriate fractions are analyzed by various means; inductively coupled argon plasma emission spectroscopy (ICPES), atomic absorption spectroscopy (AAS) or graphite furnace AAS, depending upon sensitivity required or the matrix effects on the specific analyte.

M29 Sampling TrainProduct Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

GF-3QR 3 inch Quartz Fiber Filters-100/box (MFS QR100 82mm)

GN-9AK Knock-Out Impinger, Short Stem, 500ml, Unground O-Ring Joints

GN-9A Modified Greenburg-Smith Impinger (Plain), Unground

GF-3Q 3 inch Quartz Fiber Filters-25/box (Pallflex 8.26cm)

PBT-5/8 PTFE Probe Brush, Extension, 10 Foot Flexible (Brush Not Included)

PBX-10T PTFE Probe Brush, 5/8” diameter, 4” length, 8-32 thread

NBT-1/2 Nozzle Brush, PTFE, 1/2 inch

Method 29 Recommended Accessories

Page 10: Isokinetic Part 1 Catalog 1-01-12 NP

43

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

In the Ontario-Hydro Method (ASTM D6784-02) a sample is withdrawn from the flue gas stream isokinetically through probe/filter system, maintained at 120OC (250OF) or the flue gas temperature (whichever is greater), followed by a series of impingers in an ice bath. Particle-bound mercury is collected in the front half of the sampling train. Oxidized mercury is collected in impingers containing a chilled aqueous potassium chloride solution. Elemental mercury is collected in subsequent impingers (one impinger containing chilled aqueous acidic solution of hydrogen peroxide and three impingers containing chilled aqueous solutions of potassium permanganate). Samples are recovered, digested, and then analyzed for mercury using cold-vapor atomic absorption (CVAAS) or flourescence spectroscopy (CVAFS). The scope of the method applies to determination of elemental, oxidized, particle-bound and total mercury emissions from coal-fired stationary sources with concentrations ranging from approximately .05 to 100 ug/dscm. The sample train is similar to EPA Method 5.

ONTARIO-hYdRO – METhOd (ASTM d6784-02) MERCURY

Schematic of Ontario-hydro Method Sampling Train

Product Conversion Accessories

SB-4 Impinger Box / Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

BS28WS #28 Ball Joint Clamp (Generic), Stainless Steel

NBT-1/2 Nozzle Brush, 1/2 inch diameter, PTFE Bristles

PBX-10T 10 foot Flexible PTFE Probe Brush Extension, Brush not Included

PBT-5/8 PTFE Probe Brush Tip (PTFE Barrel AND PTFE Bristles), 5/8 inch Bristle Diameter

GN-9A Greenburg-Smith Impinger (with orifice), Unground

GN-9AO Impinger Assembly, Stem with Orifice & Plate, 500ml, Unground O-Ring Joints, Greenburg-Smith

GN-11 U-Tube, #28 Unground Sockets

GF-3Q 3” Quartz Fiber Filters, 25/Box

Ontario-hydro Recommended Accessories

Ontario-hydro - Mercury Sampling Train

Page 11: Isokinetic Part 1 Catalog 1-01-12 NP

44

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

Method 201A applies to the in-stack measurement of particulate matter (PM) emissions equal to or less than an aerodynamic diameter of nominally 10 microns (PM10) and or 2.5 microns from stationary sources. A gas sample is extracted at a constant flow rate through Apex instruments cyclone, which separates PM greater than PM10.. PM .less than PM10 is collected on the in-line filter. In order to maintain a cut size of 10 microns in the cyclone, the flow rate must be maintained at a constant, discrete value during the run. Apex cyclones meets the specifications of Method 201A and allows use of the equations in Method 201A to calculate the constant sample flow rate.

pm2-k

PARTICLE SIZING - PROPOSEd MOdIFICATION METhOd 201A

Packing List

Introducing PM1 CycloneApex Instruments now offers a cyclone designed for sampling very fine particulate matter in the 1.5 to 0.5 micron range. The cyclone is based on the cyclone “V” from the Multi-stage cyclone system designed and calibrated by Southern Research Institute under contract for the EPA. The design has been modified to accept the nozzles from the PM 2.5 cyclone, which has been expanded to a set of 12 different size nozzles. The sample flow rate must be maintained, in which the constant rate determines the actual “D50” cut-point. The cyclone is followed by a 47 mm filter assembly. Quartz or PTFE coated glass fiber filters should be used to minimize reactivity with the flue gas. The cyclone and nozzles are constructed from grade 316 stainless steel with Viton o-rings. Other materials are available upon request for corrosive or high temperature applications.

pm1-k

Product Size

PM2-N1 .125 Size 1

PM2-N2 .138 Size 2

PM2-N3 .156 Size 3

Apex Expanded Nozzle SetPM2-NS Nozzle Set Includes 1 Each

Product Size

PM2-N7 .216 Size 7

PM2-N8 .234 Size 8

PM2-N9 .253 Size 9

Product Size

PM2-N4 .172 Size 4

PM2-N5 .188 Size 5

PM2-N6 .200 Size 6

PM2-NS Nozzle Set Includes 1 Each

Product Size

PM2-N10 .274 Size 10

PM2-N11 .296 Size 11

PM2-N12 .320 Size 12

PM1 Cyclone Kit ComponentsThe PM1 Cyclone is used for in-stack measurement of very fine particulate matter. The 47 mm filter assembly outlet connector has a 5/8” outer diameter for easy installation Method 5 Probe Assemblies. The cyclone kit is enclosed in a sturdy plastic case.

Product description

PM1-K PM1 Cyclone Set Includes: Cyclone Body, 12 Nozzles, (PM2-NS), Filter (SFA-47), Manual and Case

PM1 PM1 Cyclone Body Only, Stainless Steel with Viton® O-Rings

PM2-NS Set of 12 Nozzles for PM1 and/or PM2.5 Cyclone, Stainless Steel

Packing List

Product description

PM2-K PM2.5 Cyclone Set Includes: Cyclone Body, 12 Nozzles, (PM2-NS), Filter (SFA-47), Manual and Case

PM2 PM2.5 Cyclone Body Only, Stainless Steel with Viton® O-Rings

PM2-NS Set of 12 Nozzles for PM2.5 Cyclone, Stainless Steel

PM2-NSA Add-On Set of 6 Nozzles (NS-7, 8, 9, 10, 11, 12) for upgrading PM2.5 Cyclone Existing Kits, Stainless Steel

O-024V Viton® O-Ring for PM2.5 Cyclone, (2 per cyclone).

O-024H High Temperature O-Ring for PM2.5 Cyclone, Stainless Steel

MPT-6-181 Pitot Tip, 3/8” Tube, Stainless Steel Replacement for Standard Method 5 Probe Assemblies

PM2.5 Cyclone Kit Components

PM2.5 Cyclone KitThe PM2.5 Cyclone is used for in-stack measurement of particulate matter equal to or less than 2.5 microns. The shank has a 5/8” outer diameter for easy adaptation to the Method 5 Probe Assemblies. The kit is enclosed in a sturdy plastic case with 12 nozzles.

Alloy 600 Components Available. Call for Pricing.

Page 12: Isokinetic Part 1 Catalog 1-01-12 NP

45

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

PM10 Cyclone KitPM10 is used for Method 201A testing and is designed for in-stack measurement of particulate matter equal to or less than 10 microns. The shank has a 5/8” outer diameter for easy adaptation to Method 5 Probe Assemblies. The cyclone kit is enclosed in a sturdy plastic case with twelve nozzles (4” diameter port opening minimum). Call for High Temperature Alloy 600 PM10 Cyclones and Filter Holders.

pm10-k

Product description

PM10-K PM10-K Cyclone Kit, Includes: Cyclone, 12 Nozzles Set (PM10-NS), 47mm Filter Holder (SFA-47), Manual & Case

PM10 PM10 Cyclone Only, Stainless Steel with Viton® O-Rings

PM10-NS Set of 12 Nozzles for PM10 Cyclone (Now with 12 Nozzles)

O-032V Viton® O-Ring for PM10 Cyclone

O-032H High Temperature Stainless Steel O-Ring for PM10, Cyclone

MPT-6-320 Extended Pitot Tip for PM10, SFA-300, and SFA-2590

PM10 Cyclone Kit Components

PM10/2.5 Cyclone KitPM10/PM2.5 Set combines the in-stack measurement of particulate matter (PM) equal to or less than an aerodynamic diameter of nominally 10 (PM10) and 2.5 (PM2.5 ) microns from stationary sources. The sampling train and operation are identical to Method 201A except that the PM2.5 cyclone is inserted between the PM10 cyclone and the 47mm filter. The PM10 cyclone collects particulate matter greater than PM10 while the PM2.5 collects PM less than PM10 and greater than PM2.5. The in-line filter collects PM less than PM2.5 (6” diameter port opening minimum).

pm2.5-10k

Packing List

Product description

PM2.5-10K PM 2.5/10 Cyclone Kit Includes: PM10 Kit, with PM10/PM2.5 Nozzle, Cyclone Assembly, 47 mm Filter Assembly, Stainless Steel, Adapters, Pitot & Case

PM2/10-CK Connector Kit includes: GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones, NSB-16 Button Hook Adapter for connecting the PM10/2.5 Cyclones, 10MSC5-S Connector, adapts NSB-16 to PM2.5 Cyclone, 5/8” TU to 5/16” bevel seat, Stainless Steel, and N-10UBNN SS Union, 5/8”, Bored out .660 with shoulder, Body only, No Nuts or Ferrules

PM2/10-CKI Connector Kit includes: INCONEL EQUIVALENT TO: GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones, NSB-16 Button Hook Adapter for connecting the PM10/2.5 Cyclones, 10MSC5-S Connec-tor, adapts NSB-16 to PM2.5 Cyclone, 5/8” TU to 5/16” bevel seat, and N-10UBNN Union, 5/8”, Bored out .660 with shoulder, Body only, No Nuts or Ferrules

SFA-47 Filter Assembly, 47mm, 5/8TU, Stainless Steel, Method 17 In-Stack Filter Unit, 5/8 inch Tube Unions, uses 47mm diameter Filter Element

GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones

NSB-16 Button Hook Adapter for Connecting the PM10/2.5 Cyclones

10MSC5-S PM10/2.5 Connector, Adapts NSB-16 to PM2.5 Cyclone,5/8” TU to 5/16” Bevel Seat, Stainless Steel

PM10/2.5 Cyclone Kit Components

PM10/2.5 Cyclone 12 Nozzle Set - 1 Each

Product Size

PM10-N6 .215 Size 6

PM10-N7 .233 Size 7

PM10-N9 .300 Size 9

Product Size

PM10-N3 .164 Size 3

PM10-N4 .180 Size 4

PM10-N5 .197 Size 5

Product Size

PM10-N10 .342 Size 10

PM10-N11 .390 Size 11

PM10-N12 .320 Size 12

Product Size

PM10-N0 .125 Size 0

PM10-N1 .136 Size 1

PM10-N2 .150 Size 2

Recommended Accessories for Sampling with Cyclone Sets.Power Box Adapter, Includes 1/2 inch Mounting Clamp and 4 Pin Amphenol to 3 Receptacles.ua-3J

Extended Pitot Tip for PM10/2.5 Sampling, Tube Diameter 3/8”, Length 421 mmmpt-6-421

47mm Glass Fiber Filters, 100/box (Whatman 934AH-4.7cm).gF-47

Sample Frame with Probe Clamp & Impinger Box SlidessB-8

Page 13: Isokinetic Part 1 Catalog 1-01-12 NP

46

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

CI-700K Cascade Impactor Kit includes 7 stage impactor, a PRA-K pre-cutter, nozzles, interconnecting tube, glass fiber filters (45 mm, 47 mm and GFDN filters) and foil collection plate.

CI-700-K Stainless Steel Pre-Collector

Price Description

PRA-K Pre-Cutter Assembly Kit, Includes Body, Cap, Outlet Cap with Union, Nuts, Ferrulesand Set of 6 Nozzles

PRA-N4 1/8”

PRA-N6 3/16”

PRA-N8 1/4”

PRA-N10 5/16”

PRA-N12 3/8”

PRA-N16 1/2”

PRA-NS Set of 6 Pre-Collector Nozzles, Sizes 4-16

Cascade Impactor 7 Stage 47 mm filter outlet, Viton® O-Rings, Foil collection plates.

CI-700

Set of 7 Lightweight Stainless Steel Foil Collection Plate Inserts.

CI-FP

CASCADE IMPACTOR KIT

CI-700

PRA-K

CI-700-K

Data Reduction Software

Product Description

PM-2.5-10C Particle Sizing Software for PM2.5 and PM10 Cyclones

PARTICLE SIzING DATA REDUCTION SOfTwARE

functions• Calculates each stage’s aerodynamic cut point and DP50, needed to reduce particle size data. • Calculates and Stores ancillary data, such as dry gas composition and moisture content. • Reduces velocity traverse data. • Aids in selection of sample flow rates and ideal nozzle size. • Calculates flow rates and dwell times required for PM10 and PM2.5 sampling traverses. • Calculates fractional efficiencies of control devices from samples obtained at inlets and outlets.

wINCIDRS

Windows-based Cascade Impactor Data Reduction System (WINCIDRS) calculates particle size distribution of stack particulate matter (PM) taken with the Cascade Impactor, as well as particle-sizing cyclones. Developed by stack particle analysis experts, this software reduces the time and chances of error involved with reducing particle sizing data. (The PM10/2.5 Software Program (PM-2.5-10C) is extracted from WinCIDRS and simplified for use only with PM10 and PM2.5 cyclones. The calculations are similar to the WinCIDRS, scaled-down specifically for cyclone data reduction. The calculations are intensive enough to demand computer software.)

Page 14: Isokinetic Part 1 Catalog 1-01-12 NP

47

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

This isokinetic method is used to measure Condensable Particulate Matter (CPM) from stationary source emissions after particulate matter has been removed by a heated filter, such as in Method 5, 17 or 201A. The CPM is collected in dry impingers. The impinger contents are purged with nitrogen (N2) immediately after sample collection to remove dissolved sulfur dioxide (SO2) gases from the impinger. The organic and aqueous fractions are dried and the residues are weighed. The total of the aqueous and organic fractions represents the CPM.

Method 202 (dry IMpInger Method)

Schematic of the M202 Sampling train

Method 202 Sampling train

Components ListgnFA-3U-18K3” filter assembly, ungrounded glass with 90 degree inlet and outlet, open style alum clamp. With rubberized silicone filter support.

gn-9AKSAKnock-out impinger assembly,ungrounded (for HorizMM5).Includes: GN-9AKSB (Bottle), GN-9AKS-I (Short Stem),GN-9AKS-IL (Purge Stem).

gF-3tM3” PTFE membrane filter - 50 per box(Palifex 90mm).

gn-VChM-M202M202 Spiral Condenser, #28 Ball and Socket. Water Jacket Hose Barbs, High Moisture sources above 15%.

MM5-pMMini submersible coolant pump, 110V.

MM5-p Submersible coolant pump, 110V.

SB-4SdImpinger box - insulated coolant reservoir model 150, holds 8 impingers.

gA-28S4Stainless steel adapter, 28mm socket to 1/4” FNPT, 3” long 400°F rating.

SFA-116IL Stainless steel filter housing in-line 1/4” FNPT, 3” long 400°F rating. Size: 1 Micron. Other sizes available.

SFA-1101t 316L mesh stainless steel elements are recommended for filtration of heavily contaminated gases, liquids, polymers, and steam. Temperature range of -65° F to 1000°F. Withstands 1000 PSIG differential.

FILter And pUrge AdApterFilter System for Purging Method 202.

Call for more details.

A

PurgeStem

GN-VCHM-M202

GN-8

See Page 45 for PM10-2.5 Configurations

See Page 40 for Available Pumps

See Page 28 for Full-Part Assembly Break-Down

For KnockoutGN-9AKSA

Method 202 (ContInUed on next pAge)

gn-9AKSB (Bottle)gn-9AKS-I ( Short Stem)gn-9AKS-IL (purge Stem)Can be Sold Separately

gn-9AKSB

gn-9AKS-IL

gn-9AKS-I

Page 15: Isokinetic Part 1 Catalog 1-01-12 NP

48

ISoKInetIC SoUrCe SAMpLIng eQUIpMent

800-882-3214 / 919-557-7300 www.apexinst.com

pp907-049

ntg-10Unn

Quantity product description1 SB-4SD Two Section Divided Impinger Box

1 GN-VCHM-M202 Vertical Condenser #28 Socket to M202 Spiral Condenser, #28 Socket both ends Water Jacket Hose Barbs, High Moisture Source above 15%.

1 GN-9AKSA Glass Knock-out Impinger Assembly, Unground, (for HorizMM5) included with Long / Short Stem

1 GNFA-3U-18K CPM 3” Filter Assembly including Flexable TC

1 GF-3TM TPFE Membrane Filters with Support, 1 Micron Pore Size, 50/Box

1 MM5-P MM5-P Submersible Coolant Pump, 110V

1 MM5-PM Mini Submersible Coolant Pump, 110V

1 SB-8 Sample Frame with Probe Clamp

1 SFA-116IL Stainless Steel Filter Assembly, 3” L In-Line

2 SFA-1101T Stainless Steel FIlter Element

1 GA-28S4 #28 Socket Bored Purge Adapter

1 GN-9AKA Knock-out impinger assembly, ungrounded (for HorizMM5). Includes: GN-9AKSB (Bottle), GN-9AKS-I (Short Stem), GN-9AKS-IL (Purge Stem).

Method 202 SAMpLIng ACCeSSorIeS

Method 202 pUrge ACCeSSorIeS

hexAVALent ChroMIUM pFA IMpInger trAInS & ACCeSSorIeS

SK-0061H SK-0061H-V

Method 0061 Hexavalent Chromium Emissions from Stationary Sources determines hexavalent chromium emissions from hazardous waste incinerators, municipal waste incinerators, municipal waste combustors and sewage sludge incinerators. Isokinetically collected with a train where the impinger reagent is recirculated continuously. Samples are analyzed with an ion chromatograph. Method 0061H Hexavalent Chromium High Temperature Source Sampling Kit is used as an alternative for temperatures above 150°C (300° F). Option “V” is added for 240 V.

Schematic of Method 0061h Sampling train

FILter And pUrge AdApterFilter System for Purging Method 202.

Call for more details.

hexavalent Chromium Method 0061 high or Low temperature Source Sampling Kit

• 4’ Stainless Steel Probe Assembly (Not Heated)• Glass Probe Liners (2)• Glass Nozzle Set• PTFE Impingers

• 30’ Split Umbilical • Impinger Box• Peristalic Pump• PTFE Membrane• Sample Frame

Page 16: Isokinetic Part 1 Catalog 1-01-12 NP

49

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

Apex Instruments offers a wide range of filter media to meet any sampling requirements. Listed below are the standard media and sizes that Apex Instruments normally stock. Additional materials and sizes are available upon request.

FILTER MEdIA

QUARTZ FIBER FILTERSQuartz Fiber Filters are manufactured from pure quartz with-out a binder and are frequently used for sampling for metals analyses and acidic gases.

Model descriptionGF-2Q 2 inch Quartz Fiber Filters-25/box

GF-25Q 25mm Quartz Fiber Filters-100/box

GF-3Q 3 inch Quartz Fiber Filters-25/box (Pallflex 8.26cm)

GF-4Q 4 inch Quartz Fiber Filters-25/box (Pallflex 11 cm)

GF-45Q 45mm Quartz Fiber Filter-100/box

GF-47Q 47mm Quartz Fiber Filter-25/box

GF-54Q 54mm Quartz Fiber Filters-25/box (Pallflex 54mm)

GF-63Q 63.5mm Quartz Fiber Filters-25/box (Pallflex 63.5mm)

GF-3QR 3 inch Quartz Fiber Filters-100/box (MFS QR100 82mm)

GF-4QR 4 inch Quartz Fiber Filters-100/box (MFS QR100 110mm)

GF-47QR 47mm Quartz Fiber Filters-100/box (MFS QR100 47mm)

GF-90QR 90mm Quartz Fiber Filters-100/box (MFS QR100 90mm)

GLASS FIBER FILTERSGlass Fiber Filters are most commonly used filters for particulate sampling. All of the glass fiber filters are binder free and exhibit at least 99.9% efficiency for 0.3 micron dioctyl phthalate (DOP) smoke particles. Not recommended for metals analysis.

Grade E FIBER FILTERSIdeally suited for suspended solids analysis and high volume air monitoring applications. Softening point of glass fiber is 500°C, therefore upper limit temperature in use is 475°C. Low fiber shedding improves quality assurance of test results. high loading capacity. This media meets requirements for standard method 2540D and EPA Method 160.2 for establishing water quality in suspended solids content.

Model descriptionGF-2 2 inch Glass Fiber Filters-100/box

(934AH-5.5cm)

GF-2X6.5

2x6.5 inch Glass Fiber Filters-100/box (934AH)

GF-3 3 inch Glass Fiber Filters-100/box (934AH-8.26cm)

GF-4 4 inch Glass Fiber Filters-100/box (934-AH-11cm)

GF-45 45mm Glass Fiber Filters-100/box (934-AH-45mm)

GF-47 47mm Glass Fiber Filters-100/box(934AH-4.7cm)

GF-63 63.5mm Glass Fiber Filters-100/box (934-AH-63.5mm)

GF-90 90mm Glass Fiber Filters-100/Box (934AH-9.0cm)

GF-2E 2 inch Glass Fiber Filters-100/box Grade E

GF-3E 3 inch Glass Fiber Filters-100/box Grade E

GF-4E 4 inch Glass Fiber Filters-100/box Grade E

GF-25E 25mm Glass Fiber Filters-100/box Grade E

GF-47E 47mm Glass Fiber Filters-100/box Grade E

GLASS FIBER FILTERS

Page 17: Isokinetic Part 1 Catalog 1-01-12 NP

50

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

ALUNDUM® THIMBLES (CERAMIC)Alundum® Thimbles are used for in-stack filtration for process engineering studies when a large sample is needed for analyses. These thimbles are made from fused alumina oxide and remain very constant in weight and can be re-used an infinite number of times. There are two different porosity thimbles that can be used in the SFA-300 thimble holder. The medium porosity retain particles 5 micron and larger and the coarse retain particles 20 micron and larger.

PTFE COATED GLASS FIBER FILTERS PTFE Coated Glass Fiber Filters are constructed from borosilicate microfibers and bonded with PTFE. The filters can be folded & handled without loss of fibers. Great for especially low loading rates. Specifically recommended for Method 26 & PM10 sampling.

Product descriptionGF-2T 2 inch PTFE Coated Glass

Fiber Filters-100/box

GF-3T 3 inch PTFE Coated Glass Fiber Filters-100/box (Pallflex 82.6mm)

GF-4T 4 inch PTFE Coated Glass Fiber Filters-100/box (Pallflex 11cm)

GF-25T 25mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 2.5 cm)

GF-47T 47mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 4.7cm)

GF-90T 90mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 90mm)

PTFE FILTER MEMBRANESPTFE Filter Membranes are produced of pure PTFE resins. They withstand the most severely corrosive conditions at temperatures as high as 500°F (260°C) and down to the cryogenic range. The membrane is hydrophobic and maintains its strength wet or dry.

Model descriptionTF1121 PTFE Membrane, 47mm,

0.45 Micron (10/pack)

TF1131 PTFE Membrane, 47mm, 1-2 Micron (10/pack)

TF1141 PTFE Membrane, 47mm, 5-6 Micron (10/pack)

PTFE FILTER MEMBRANES

Product descriptionGF-90T 90mm PTFE Coated Glass Fiber Filters-100/box

(Pallflex 90mm)

GF-90T 90mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 90mm)

GF-3TPG 3 inch PTFE Coated Glass Fiber Filters-50/box (MFS PG60) 82mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-4TPG 4" PTFE Coated Glass Fiber Filters-50/box (MFS PG60) 110mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-25TPG 25mm PTFE Coated Glass Fiber Filters-100/box (MFS PG60) 25mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-47TPG 47mm PTFE Coated Glass Fiber Filters-100/box (MFS PG60) 47mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

Model descriptionGF-300C Alundum Thimble, medium porosity, 5+ micron retention, 34x100ml,

round bottom, fits SFA-300 use with additional O-ring, O-123V.

GF-300-C Alundum Thimble, COARSE porosity, 20 micron retention, 34x100ml, round bottom, fits SFA-300 use with additional O-ring, O-123V.

GF-300C

IN-STACK THIMBLES AND ACCESSORIES Apex Instruments stocks a variety of Fiber Thimbles for in-stack particulate sampling. The thimbles are seamless, high purity filters and available from a choice of two different types of fibers: Borosilicate glass and quartz. Borosilicate glass fiber thimbles are acid washed to reduce the trace metal content to an absolute minimum. Quartz fiber thimbles are strengthened with alumina and are prefired at 900°C for 2 hours during manufacturing to stabilize the weight prior to use. The gas collection efficiency of the thimbles is 99.9% (0.3 micron DOP). The 25 x 90mm thimbles are specifically manufactured for stack sampling and tapered for ease in loading. Cellulose thimbles are available upon request.

GF-2590Q

Model descriptionTF1165 PTFE Membrane, 25mm, 30-60 Micron (10/Pack)

GF-3TM 3 inch PTFE Membrane Filters-50/box (82.6mm) PTFE filter media provides durability for hostile acid aerosol monitoring. 1.0µm pore size membrane.

PTFE FILTER MEMBRANES

Model descriptionGF-190Q 19X90mm Quartz Fiber Filter

Thimble-25/box (For SFA-190)

GF-300Q 30x100mm Quartz Fiber Filter Thimble-25/box (For SFA-300) grade 88R

GF-2590Q 25x90mm Tapered Quartz Fiber Thimble-10/box (For SFA-2590) Grade 88R

QUARTZ FIBER THIMBLESModel descriptionGF-190 19x90mm Glass Fiber Filter

Thimble-25/box (For SFA-190)

GF-2590 25x90mm Tapered Glass Fiber Thimble -10/box (For SFA-2590) Grade 86R

GF-300 30x100mm Glass Fiber Filter Thimble-25/box (For SFA-300) Grade 86R

GLASS FIBER FILTER THIMBLES

Page 18: Isokinetic Part 1 Catalog 1-01-12 NP

51

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

PTFE Probe Brush Extensions The flexible PTFE Probe Brush Extension attaches to the PBT-5/8 or PB-5/8. Made with 8/32 threads with a phenolic knob. Please specify length.

PTFE Probe BrushAll PTFE construction. The PBT-5/8” diameter with four spiral rows of black PTFE bristles. Over all length is 2”. The shaft is 1/4” diameter with 8-32 female threads. PTFE Barrel and PTFE Bristles.PBT-5/8

SAMPLE RECOVERY

PBT-5/8

NB-SET

B-3

B-4

PBX-S

Modular Probe Brush Set The PBX-S Modular Probe Brush Set contains two of the 5/8” stainless steel twisted wire brushes with nylon bristles and a total of 13’ in stainless steel extensions.PBX-S

Model description

PB- 5/8A Probe Brush/Stainless Steel, Nylon Bristles & Allen Set Screw (HD1088)

PBX-2 2’ Probe Brush Extension, Stainless Steel

PBX-3 3’ Probe Brush Extension, Stainless Steel

PBK-832 Probe Brush Knob

NOZZLE BRUSh SET The NB-SET Nozzle Brush Set includes one each of the three most popular sizes in a convenient carrying tube. (#3,#5,#8)NB-SET

B-1

Impinger Bottle Brush with Plastic Handle and Nylon Bristles.B-1

Impinger Bottle Brush

B-2

Flask Brush, Stainless Steel Handle and Nylon Bristles.B-2

Flask Brush

Filter Brush, 3/16” diameter, Stainless Steel Handle and Nylon Bristles, 5/16”.B-3

Filter Recovery Brush

Rubber Policeman with 18” Delrin® HandleB-4

Policeman

Model description

PBX-4T 4” PTFE ProbeBrush Extension

PBX-6T 6” PTFE Probe Brush Extension

PBX-8T 8” PTFE Probe Brush Extension

PBX-10T 10” PTFE Probe Brush Extension

PBX-12T 12” PTFE Probe Brush Extension

Brush Sold Separately

PTFE NOZZLE BRUShES Nozzle Brush NBT-1/2 is constructed of pure PTFE featuring a 1/8” diameter shaft with 1/2” long soft PTFE bristles. NBT-1/2

NBT-1/2

PBX- T

NOZZLE BRUShES Apex Instruments Nozzle Brushes feature stainless steel handle and nylon bristles. Super flexible for cleaning button hook nozzles with eye tip to reduce scarring of the nozzle.

Model description

NB-3 3/16” diameter, Nylon Bristles

NB-5 5/16” diameter, Nylon Bristles

NB-8 1/2” diameter, Nylon Bristles

NB-5

NB-8NB-3

20 ft.Teflon Sample Line Brush, 1/8” diameter rod with 1/2” long bristles B-5

Sample Line Brush

Page 19: Isokinetic Part 1 Catalog 1-01-12 NP

52

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

250ML-CyL-PMP

Aluminum Weighing dishes (70 ml)100/pack.25433-062

Aluminum Weighing dishes 100 Pack (12.1 cm) 12175-001

Petri dish 100x15mm (3” Diameter),25/pack. 25373-1100

Petri dish 150x15mm (4” Diameter), 10/pack25373-187

Graduated Cylinder 250ml, Plastic250ML-CYL-PMP

Graduated Cylinder 250ml, Glass250ML-CYL

TW-1

Nylon TweezersTW-1

Polypropylene FunnelTop Diameter 108mm.

30255

Funnel Parafilm M, Laboratory Sealing Film, Roll is 2” x 250 ft.PARA-2X250

Synthetic Cotton Balls (For Impinger Outlet Filter), 300/bagMS-1

Cotton Balls

SAMPLE RECOVERY BOTTLES

POLYEThYLENE SAMPLE BOTTLES 125 mL vw/Wide Mouth, w/Cap.WB-1W250 mL w/Cap.WB-2p250 mL w/Wide Mouth.WB-2pW 16oz. / 500 mL w/Wide Mouth.WB-4p1000 mL w/Wide Mouth.WB-10p1000 mL w/Wide Mouth.WB-1000pW

Wide Mouth Bottles for Easy Filling and Pouring. The HDPE bottle with polypropylene closures are made of FDA compliant material. Recycling code molded into base of bottles. Simple to pour-wide mouth bottles. Chemically resistant. Leak proof, firm. Excellent for packaging chemicals, pharmaceuticals and adhesives.

WB-2P/with Cap250ml

WP-4B/with Cap500ml

FEP WASh BOTTLE500mL Wash Bottles, FEP.WB-500Fep

WB-500FEP

GSB-250

GLASS BOTTLES250mL Glass Sample Bottles with PFA-Lined Lid.Case of 12.gsB-250

SAMPLE RECOVERY ACCESSORIES

WB-5P

PLASTIC WASh BOTTLE500mL Plastic Wash BottlesWB-5p

Page 20: Isokinetic Part 1 Catalog 1-01-12 NP

53

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

dESICCATOR ANd dESICCANTS Acrylic Desiccator Cabinets feature adjustable shelves with grooves for positioning, removeable lip tray, gasketed door, built-in hygrometer. Cabinets do not include Desiccant, order separately.

31000

www.belart.com

Features• Patented Sealed Construction is Airtight, Dust and Moisture Free.• Portable and Stackable with a Small Footprint.

PORTABLE dESI-VAC CONTAINER Desiccator with a vacuum pump is ideal for drying, preserving, storing, and even shipping samples. Vacuum pump built into the top removes air with manual strokes. Rubber O-ring sealed cover maintains vacuum. Achieves a vacuum of better than 200 inches of water (15 inches of mercury). A release button on top allows air into the container to remove the lid. Sample Humidity Sponges™ desiccant drying packets are included. O-ring-sealed cover maintains vacuum. Achieves a vacuum of better than 200 inches of water (15 inches of mercury A release button on top allows air into the container to remove the lid. Keep powder dry. Plastic container is ideal for storing chemicals, powders, tissues, plant sections, electronics, and weighing samples. Vacuum and desiccants keep mate-rial dry. Supplied with a vacuum indicating button that confirms interior vacuum and a dial hygrometer that displays 0 to 100% relative humidity with a resolution of 2%RH.Dimensions: HxWxD: 11” x 9” x 10”.

des-3164dES-3164

• Embedded UV Protection and Superior Chemical Resistance.• Built-in Hygrometer for Quick Check on RH Levels.• Rugged Construction with Sturdy Latches and Lock Provisions.

Model description dimensions Features

DES-10000 Desiccator Cabinet 8.4” x 13.4” x 16.3” Gasketed door, built in hygrometer, 0.75 cu.ft.

DES-21000 Desiccator Cabinet 12.4” x 13.4” x 16.3”, Gasketed door, 2 shelves, built in hygrometer 1.17 cu.ft.

DES-21115 Auto-Desiccator Cabinet

12.4” x 13.4” x 16.3” Gasketed door, 2 shelves, built in hygrometer 1.17 cu.ft. 110V

DES-21115V Auto-Desiccator Cabinet

12.4” x 13.4” x 16.3”, Gasketed door, 2 shelves, built in hygrometer 220V fan, 1.17 cu.ft.

DES-31000 Desiccator Cabinet 16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer stackable

DES-31115 Auto-Desiccator Cabinet

16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer stackable, 110V

DES-31115V Auto-Desiccator Cabinet

16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer 220V fan

DES-40000 Desiccator Cabinet 13.4” x 20.4” x 16.3”,

Gasketed door, 2 shelves, horizontal Profile

DES-41115 Auto-Desiccator Cabinet

20.4” x 13.4” x 16.3” Gasketed door, 3 shelves, built in hygrometer

DES-41220 Auto-Desiccator Cabinet

20.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer, 220V fan

Page 21: Isokinetic Part 1 Catalog 1-01-12 NP

54

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

Adsorption Housing, 1/4” FNPT Fittings. Without Sorbent.

SILICA GELBlue Indicating, 12/case, 250 ml per bottle.

sg-kitSG-KIT

Apex Instruments Silica Gel is primarily used for drying sample gas prior to measurement and can absorb moisture 40% of its weight. The silica gel can be regenerated by drying in an oven and used over and over again.

SILICA GEL

SILICA GEL3-5mm Bead, Indicating, 2.3Kg.

sg-3/5B

24005 14005

Part Number description

14005 DRIERITE®, Nonindicating 10-20 Mesh, 5 Lbs. (2.3 kg)

23005 DRIERITE®, Indicating 8 Mesh, 5 Lbs. (2.3 kg)

24005 DRIERITE®, Indicating 10-20 Mesh, 5 Lbs. (2.3 kg)

26840 DRIERITE®, Cartridge, 50g H2O Capacity

26809 Mounting Clip for Use with Gas Drying Units

SG-3/5B

The activated alumina is primarily used for air drying at low temperature applications, 5.5 lb. container.

80% Activated Alumina (White). 1/8” Diameter Beads.

20% Silica Gel (Blue) 3-5 mm Beads.

Aluma-sorb

ACTIVATEd ALUMINA WITh SILICA GEL

Aluma-sorb

SILICA GEL3-5 mm Bead, Bulk55 LBS, CONTAINER.

sg-3/5B-55

Ah-610R

dRIERITE® dESICCANTSApex Instruments carries both non indicating and indicating DRIERITE®. (anhydrous calcium sulfate) Economical to use, it can be regenerated repeatedly. The indicating DRIERITE® is impregnated with cobalt chloride: blue when dry and changes to pink upon absorption of moisture.

SG-3/5B-55

ah-610r

Page 22: Isokinetic Part 1 Catalog 1-01-12 NP

55

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

BALANCES

MOdEL dESCRIPTION

BAL-EJ1500 1500g x 0.1 g.

BAL-EJ3000 3100g x 0.1 g.

BAL-EJ6100 6100g x 0.1 g.

BAL-EJ02 USB Interface with Cable

BAL-EJ12 Carrying Case

EJ-SERIES• Easy to read LCD Display with Backlight

• Percentage and Counting

• USB or RS-232 Interface Optional

• Battery Operated (4 x AA not included)

• AC Adapter Included

• Pan Size: 5” x 5.5”

• Check-Weighing Capacity

• 5 Year Warranty

PORTABLE BALANCES

MOdEL dESCRIPTION WEIGhT

BAL-W1000ASTM Weight for Electronic Balance. 1 kg. ASTM GRADE 7

BAL-W2000ASTM Weight for Electronic Balance. 2 kg. ASTM SHAPE

BAL-W5000ASTM Weight for Electronic Balance. 5 kg. Class F, meet Tolerances of NIST

CALIBRATION WEIGhTS

COMES wiTh CERTiFiCATE OF CONFORMANCE

Page 23: Isokinetic Part 1 Catalog 1-01-12 NP

56

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

BALANCES

MOdEL dESCRIPTION PAN SIZE

BAL-HR60-C 60g x 0.1mg with RS-232C. 3.3”

BAL-HR120-C 120g x 0.1mg with RS-232C. 3.3”

BAL-HR200-C 210g x 0.1mg with RS-232C. 3.3”

BAL-HR202i 220g/51g x 0.1mg/0.01mg Semi-Micro with R-232C. 3.6”

hR-SERIES• Percentage and Counting Modes.

• Digital Preset Tare.

• One Touch Printing.

• Last Digital Suppression.

• Standard Underhook.

• Optional Rechargeable Battery Pack.

• GLP/LIMS/ISO Compliant.

• RS-232C Standard.

• 5 Year Warranty.

ANALYTICAL BALANCES

Analytical Balances - Calibration Weight Set

MOdEL

BAL-W1-100

dESCRIPTIONWeight Set - 1mg-100gStainless Steel Calibration Weight Set for Lab Use. Set of 9 Weights Plus Fractional Weights in Wooden Storage Box.

Note: Please check with State Department of Weights and Measurements for calibrations.

Page 24: Isokinetic Part 1 Catalog 1-01-12 NP

57

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

METER CALIBRATION

CALIBRATION SERVICESApex performs both calibrations using a wet test meter and bell-prover primary standard. Calibration services are available from Apex Instruments on a fee per console basis. Extra charge for low flow. All console and dry gas meter calibrations are conducted in accordance with U.S. EPA standards. Apex Instruments calibrates source sampler consoles, reference dry gas meters, orifices and pitots.

Calibration being performed with Wet Test Meter

dRY GAS SECONdARY REFERENCE METER (ENGLISh)Dry Gas Meter Secondary Reference Meter (Standard) with 15 pt cal, valve, 5’ hose, 1/2” Quick Connect. Used for calibrating Method 5 Source Sampler Consoles.

dgm-110sr

SECONdARY REFERENCE METER (METRIC)Dry Gas Meters Secondary Reference Meter (Metric AP25) with 15 pt cal, valve, 5’ hose, 1/2” Quick Connect.Used for calibrating Method 5 Source Sampler Consoles.

dgm-ap25sr

METER CALIBRATION EQUIPMENT

Model description

DGR-2VER Verification of DGM for Secondary Reference, 2 Point Verification of Previous Calibration

DGMC-5A Pre-Test 5 Point Calibration for Compatible Meter Consoles

DGMC-3A Post Test 3 Point Calibration for Meter Consoles

CAL-ORF Orifice Calibration, 3 Point

dRY GAS METER CALIBRATION SERVICES

dGM-110SR dGM-AP25SR

Page 25: Isokinetic Part 1 Catalog 1-01-12 NP

58

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

U.S. EPA allows critical orifices to be used as calibration standards. The orifice calibration set contains five of our critical orifices with 1/2” quick connects and software. Recalibration recommended annually. Calibration Orifice Set, 5 Calibrated Critical Orifices and Spreadsheet Diskette for Method 5.

CALIBRATION ORIFICE SET

m5Co-set....$510.00

Available on CD

Model A description: Shinagawa Precision Wet Test Meter Weight height Width depth

W-NK-0.5A Max Flow 5 LPM, 0.5 Liter per Revolution 4.5kg 420 290 190

W-NK-1A Max Flow 10 LPM, 1 Liter per Revolution. 6.0kg 450 315 210

W-NK-2A Max Flow 20 LPM, 2 Liter per Revolution 9.0kg 390 350 255

W-NK-2.5A Precision Meter, 2.5 Liter Capacity, 5 to 1500 L/HR 9.0kg 390 350 255

W-NK-5A Precision Meter, 5 Liter Capacity, 5 to 3000 L/HR 25kg 575 455 295

W-NK-10A Precision Meter, 10 Liter Capacity, 20 to 6000 L/HR 35kg 656 535 380

The Best Standard for Calibration of dry Gas Meters.

Different Models Available.

The Model W-NK Wet Gas Meter is a net-volume type integrating flowmeter that employs a drum as the metering element. As the drum is sealed with water or other fluid, the Model W-NK provides the measurement of any gas irrespective of the gas specific gravity and viscosity. Further, since this gas meter permits the measurement of very small flows, exhibits high reproducibility, and offers various other excellent features, it properly serves as a standard as well as a testing instrument.

PRECISION WET TEST METERSCALIBRATION EQUIPMENT ANd SERVICES

Model B description: Shinagawa Precision Wet Test Meter Weight height Width depth

W-NK-0.5B Max Flow 5 LPM, 0.5 Liter per Revolution, Corrosion Resistant 4.5kg 420 290 190

W-NK-1B Max Flow 10 LPM, 1 Liter per Revolution, Corrosion Resistant 6.0kg 450 315 210

W-NK-2B Max Flow 20 LPM, 2 Liter per Revolution, Corrosion Resistant 9.0kg 390 350 255

W-NK-2.5B Precision Meter, 2.5 Liter Capacity, 5 to 3000 L/HR, Corrosion Resistant

9.0kg 390 350 255

W-NK-5B Precision Meter, 5 Liter Capacity, 5 to 3000 L/HR, Corrosion Resistant

25kg 575 455 295

W-NK-10B Precision Meter, 10 Liter Capacity, 20 to 6000 L/HR, Corrosion Resistant

35kg 656 535 380

W-NK

Model description

M5CO-40 Calibration Critical Orifice, Size 40, Flow Rate. ~.31cfm (~8.8 lpm) with 1/2” Male QC

M5CO-48 Calibration Critical Orifice, Size 48, Flow Rate. ~.46cfm (~13.0 lpm) with 1/2” QC

M5CO-55 Calibration Critical Orifice, Size 55, Flow Rate. ~.61cfm (~17.3 lpm) with 1/2” QC.

M5CO-63 Calibration Critical Orifice, Size 63, Flow Rate. ~.79cfm (~22.4 lpm) with 1/2” QC.

M5CO-73 Calibration Critical Orifice, Size 73, Flow Rate. ~1.1cfm (~31.14 lpm) with 1/2” QC.

Orifice Set Contains the following:

Page 26: Isokinetic Part 1 Catalog 1-01-12 NP

59

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

dIAL CALIPERS

Geometric of Type-S Pitot Tube to Method 2.

pt-Cal-gWind Tunnel of Type-S Pitot Tube to Method 2.

pt-Cal-W

PITOT CALIBRATION SERVICES

ThERMOCOUPLE SIMULATOR / CALIBRATOR This Thermocouple Simulator/Calibrator is convenient for checking the accuracy of most Controllers and Temperature Displays. Whe Cold Junction Compensated, is calibrated without External Compensators or Icebaths the Simulator Source is designed for Type-K Thermocou-ples and has 22 precise test points.

m5C-520

dial Calipers are used for measuring nozzle diameter and inspection of pitots. Dial Caliper, 0-6”/ 150mm Direct inch/Metric Conversion.

m5C-3d

NOZZLE CALIBRATION

CALIBRATION EQUIPMENT ANd SERVICES

M5C-520

BULL’S EYE LEVELBull’s Eye Level is 1/2” diameter and used for pitot calibrations. Comes with thumb screws for clamping to pitot.

m5C-2

M5C-2

Pendulum Style Inclinometer for the Calibration of Type-S Pitots.

inC-a300

A300 LEVEL INdICATOR

INC-A300

PITOT AUdIT EQUIPMENT & MANOMETERS

Meriam Handheld, LCD DISPDigital Manometer, Hand held, 0-28 inch H2O Selectable Range, English/Metric, with certificate of NIST traceability.

dhm-m100

hANdhELd MANOMETER

dhM-M100

hANdhELd MANOMETER LCD DISP., Digital Manometer, Method 2, Hand held, 0-10 inch H2O Selectable Range, English/Metric.

dhm-28-10

dhM-28-10

MANOMETER SOFTWARE Software and cable for Digital Manometer, HM28 series.

dhm-28-1

MANOMETER dIGITAL dISPLAYDP-CALC Micromanometer makes differential pressure measurements, static, total, and velocity pressures as well as pressure drops across filters, coils, fans, and diffusers. Differential and static pressure from -15 to +15 in. H2O (-3735 to +3735 Pa) lightweight and durable design with an easy-to-read display, certificate of NIST traceability.

dhm-5825

Page 27: Isokinetic Part 1 Catalog 1-01-12 NP

60

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

MONORAILS

MONORAIL hARdWARE

(Threaded pipe flanges are available in 3”, 4” or 6”, stainless steel or aluminum.) Note: The chain must be attached to the stack so that the chain angle to the monorail is no less than 30° (45° is recommended).

PF- CSPipe Flange

PART # Monorail with Cable and Chain LF

P1001-10 MONORAIL, 10FT, STEEL Heavy Duty, Double Channel, W/CHAIN, L-Bracket & Hardware.

10

P1001-12 MONORAIL, 12FT, STEEL Heavy Duty, Double Channel, W/CHAIN, L-Bracket & Hardware.

12

P1001-14 MONORAIL, 14FT, STEEL Heavy Duty, Double Channel, w/ Adjustment Chain, L-Bracket & Hardware.

14

P1001-16 MONORAIL, 16FT, STEEL Heavy Duty, Double Channel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

16

P1001-17 MONORAIL, 17FT, STEEL Heavy Duty, Double Channel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

17

P1001-18 MONORAIL, 18FT, STEEL W/CHAIN Heavy Duty, DoubleChannel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

18

PART # Flange

PF-3CS Flange, 3” 150 lb. FF, 2.67 Bored, Stainless Steel, with Threaded Coupling.

PF-4CS Flange, 4” 150 lb. FF, 2.67 Threaded, Stainless Steel, with Threaded Coupling.

PF-6CLS Flange, 6” 150 lb. FF, 2.67 Bored, Stainless Steel with Cam-lock Connector.

See Accessories Section for Different Configurations.

PART # Trolley and Monorail Support Bracket

P2751 MONORAIL, TROLLEy Swivel Frame Trolley with Eyebolt, 1 Foot Chain and Snap-hook.

P501 MONOMOUNT, MONORAIL SUPPORT Support Bracket; Fits 3”, 4”, 6” & 8”, Standard Pipe Flanges, Includes P1354 Hinge, (4) P3010 Nuts and P371 Bolts.

Link to Flanges

LF 6 7 8 9 10 12

Part # P1000-6 P1000-7 P1000-8 P1000-9 P1000-10 P1000-12

Probe Size

For use with probes over 6’

For use with probes over 7’

For use with probes over 8’

For use with probes over 9’

For use with probes over 10’

For use with probes over 12’

Monorail with ChainHeavy Duty Steel Monorail with Chain, L-Bracket and Hardware (for use with probes).

Page 28: Isokinetic Part 1 Catalog 1-01-12 NP

61

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

XC-522 and XC-572 Components ListPart Number Description QC-MAN-M2 QC-Manometer, M-1/4HB, Delrin XC-10U Black RotoRack Shallow Case M-RA911 Switch, Curvette, EC Comp., I-O AM-MCP Replacement Meter Console Wired Amphenol Sub-Assembly M-422B Bracket, Manometer, Adjust, Stainless Steel M-422DS Manometer Displacer Knob L-441160 Latch, Panel, Screw, Large, Sou 3439T12 Webbing, 2”, Black Nylon M-CBR5A-M Magnetic Type Circuit Breaker Rocker Switch, 5 Amp., 120V M-CBR3A-M Magnetic Type Circuit Breaker Rocker Switch, 3 Amp., 240V

Part Number Description TC-765KF Display, TC, PNI, LED, 120/220V M-SD31 Controller, Temp, Red LED, Watlow MC-T Timer, MC, Veeder-Root M-SCKT15A Conn, Pwr, IEC Inlet 15A/250V M-49BK Recept, EL, Snap-In, Term M-31302A Switch, TC. 7 Channel TC-PJK TC Jack, Type K, PNL, Snap-In QC-BHF8-SS QC, Blkhd, 1/2IN-1/2TU, F, SS QC-BHF4-SS QC, Blkhd, 1/4IN-1/4TU, F, SS QC-BHF6-SS QC, Blkhd, 3/8IN-3/8TU, F, SS QC-BHM6-SS QC, Blkhd, 3/8IN-3/8TU, M, SS B2VH-6S Valve, Ball, 3/8TU, SS, PNL, Nut NV3HA-6S Valve, Needle, Angle, 3/8T-3/8T, S DGM-110 Meter, Dry Gas, 110 Rockwell G301U Gage, Vac, 0-30HG, 1.5IN, PNL M-42210 Manometer, Dual, PNL, 0-10” H2 QC-MAN-F3 QC-Manometer, F-1/8MNPT, S

1234567891011121314151617

18192021

22

23242526

27

xC-522 SoUrCE SAMPLING CoNSoLE (ENGLISh) xC-572 SoUrCE SAMPLING CoNSoLE (METrIC)

TC-765KF

Temperature Display

Manometer Quick Connects

Fine Control Valve

Manometer Zero Adjust Knobs

Manometer Level Adjust

Standard Stainless Steel Pitot Quick

Connects

Standard Stainless Steel Sample Quick Connect

Standard StainlessSteel Female Pump Connection (Pressure)

UmbilicalCable Power Connection

Color Coded Thermocouple Jacks

7-ChannelTemperature

Selector Switch

Vacuum Gauge

Elapsed Timer

Rugged Custom Molded X-Case

Digital Filter and Probe Temperature

Controllers

Stainless Steel MaleNon-Reversible Pump

Quick Connect(Vaccum)

Strap

9

10

11

1

7

XC-10U19

13

4

21

ElectricReceptacle

Power Connect Inlet

25 3439T12

Heavy Duty Panel Latches

24 L-441160

XC-522 Dry English Gas Meter14 dGM-110

CoarseControl Valve

12 B2Vh-6S

Dual Column

Manometer

16 M-42210

1718 QC-MAN-M2

QC-MAN-F32 M-Sd31

MC-T

G301U

3

15

M-31302A 6

TC-PJK

QC-BhM6-SS

QC-BhF6-SS

5M-49BK

QC-BhF8-SS8

QC-BhF4-SSAM-MCP NV3hA-6S

M-422B22

M-422dS23

Rocker Switches

M-RA91120

M-SCKT15A

XC-522

28 dGM-AP25

XC-572 Dry Metric Gas Meter

XC-572 (Metric) DGM-AP25 Meter, Dry Gas, AP25 W/Union 28

Magnetic Type Circuit Breaker Rocker Switch

M-CBR3A-M27

M-CBR5A-M26

Call for information on 110V / 240V Models.

Page 29: Isokinetic Part 1 Catalog 1-01-12 NP

62

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

ConVersion FaCtorsConversion Factors

To Convert From to multiply ByareaSquare Feet (ft2) Square Centimeters (cm2) 929.0304

Square Feet (ft2) Square Meter (m2) 0.09290304

Square Feet (ft2) Square Inches (in2) 144

Square Inches (in2) Square Centimeters (cm2) 6.4516

LengthFeet (ft....) Centimeters (cm) 30.48

Feet (ft....) Meters (m) 0.3048

Feet (ft....) Inches (in) 12

Inches (in) Millimeters (mm) 25.4

Inches (in) Centimeters (cm) 2.54

Mass/ForcePounds (lb) Grains (gr) 7000

Pounds (lb) Grams (g) 453.59237

Grains (gr) Grams (g) 0.06479891

Kilograms (kg) Pounds (lb) 2.2046226

Kilogram-force (kgf) Newton (N) 9.80665

Pound-Force9 (lbf) Newton (N) 4.44822

temperatureDegrees Celsius (°C) Kelvin (K) K = °C + 273.15

Degrees Celsius (°C) Degrees Fahrenheit (°F) °F = 9/5 (°C + 32)

Degrees Fahrenheit (°F) Degrees Rankine (°R) °R = °F + 459.67 = 1.8k

Degrees Fahrenheit (°F) Degrees Celsius (°C) °C = 5/9 (°F -32)

Power, Energy, heatBritish Thermal Unit per Min. (Btu/min.) Steam, Pounds per Hour (lb/hr Steam) 1 X 103

Horsepower (hp) Watts (W) 745.7

Horsepower, boiler (hp) British Thermal Unit Per Hour (Btu/hr) 33445.7

Horsepower, boiler (hp) Kilowatts (kW) 9.8095

Kilowatts, Hours (kWhr) British Thermal Unit Per Hour (Btu/hr) 3414.43

British Thermal Unit, mean (Btu) Kilogram-Calories (kcal) 0.252

British Thermal Unit, mean (Btu) Watts per Second, Joule (J) 1055.06

PressureInches of Mercury (in Hg) Millimeters of Mercury (mm Hg) 25.4

Inches of Mercury (in Hg) Inches of Water (in H20) 13.6

Inches of Mercury (in Hg) Atmospheres (atm) 0.0334211

Inches of Mercury (in Hg) Kilopascals (kPa) 3.386388

Atmospheres (atm) Bars (bar) 1.01325

Atmospheres (atm) Pounds per Square Inch (psi) 14.695949

Pascals (Pa) Newton per Square Meter (N/m2) 1.0

VolumeCubic Meters (m3) Cubic Feet (ft3) 35.314667

Cubic Feet (ft3) Liters (l) 28.136847

Liters (l) Cubic Centimeters (ccm) 1000

Page 30: Isokinetic Part 1 Catalog 1-01-12 NP

63

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

equations

Page 31: Isokinetic Part 1 Catalog 1-01-12 NP

64

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

Avogadro’s Number 6.02 x 1023 atoms/g atomGas Constants 82.05 atm cm3/(g-mole * K) 1.987 cal/(g-mole * K) 10.731 ft.... lb in2/(lb-mole * oR) 0.732 ft3 atm/(lb-mole * oR)1 g-mole of Ideal Gas 24.05 Liters at US EPA Standard Conditions

Constants

Standard Temperature (Tstd) 20oC (68oF)Standard Pressure (Pstd) 760mm Hg (29.92in Hg)

us epa standard Conditions

gas ConCentration unitsParts-per-million by volume (ppmv) to milligrams per dry standard cubic meter (mg/dscm)

Correct to x% O2

−−

×=)(2

2%@ %9.20

%9.202

dryactualsOxs O

OxCC

Gas Concentration UnitTo Convert From To Multiply ByParts-per-million(ppm) SO2 Nanogram/Std Cubic Meter (ng/scm) SO2 2.66 x 106

Parts-per-million(ppm) SO2 Pounds/Std Cubic Foot (lb/scf) SO2 1.660 x 10-7

Parts-per-million(ppm) NOx Nanogram/Std Cubic Meter (ng/scm) NOx 1.912 x 106

Parts-per-million(ppm) NOx Pounds/Std Cubic Foot (lb/scf) NOx 1.194 x 10-7

Page 32: Isokinetic Part 1 Catalog 1-01-12 NP

65

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

An Sampling Nozzle Cross-Sectional Area, mm2 (in2)As Stack Cross-Sectional Area, m2 (ft2)Bws Percent Moisture in Stack Gas, % H2OCp Pitot Tube Calibration CoefficientCp(std) Standard Pitot Tube Calibration Coefficientcs Particulate Concentration in Stack Gas, g/dscm gr/dscm (lb/dscf gr/dscf)De Equivalent Diameter, m (ft....)Dn Sampling Nozzle Diameter, mm (in)∆p Stack Gas Velocity Pressure, mm H2O (in H2O)(∆p1/2) avg Average of the Squareroots of Velocity Pressure, (mm H2O)1/2 (in H2O)1/2

%EA Percent Excess Air, %Fd F factor for dry effluent, used with percent O2, dry basisFo Fuel Factor∆H@ Pressure Drop across Orifice Meter for 21.2 lpm (0.75cfm) at Std Conditions, mm H20 (in H2O)∆H Pressure Drop across Orifice Meter, mm H20 (in H2O)%I Isokinetic Sampling Rate, %K Isokinetic Rate ConstantK’ Critical Orifice Calibration FactorKp Pitot Tube ConstantL Length of Duct Cross-Section at Sampling Site, m (ft....)m Mass, g (lb)Md Stack Gas Dry Molecular Weight, g/g-mole (lb/lb-mole)Ms Stack Gas Wet Molecular Weight, g/g-mole (lb/lb-mole)pmr Pollutant Mass Emission Rate, kg/hr (lb/hr)Pb Barometric Pressure, mm Hg (in Hg)Ps Absolute Stack Pressure, mm Hg (in Hg)Pstd Standard Pressure, 760 mm Hg (29.92 in Hg)Qaw Actual Wet Volumetric Flowrate, acmm (acfm)Qsd Dry Standard Volumetric Flowrate, dscmm (dscfm)ρw Density of Water, 0.9982 g/mlθ Time (minutes)Ts Stack Temperature, oC (oF)Tstd Standard Temperature, 293K (528oR)Tamb Ambient Temperature, oC (oF)Vcr Critical Orifice Volume, m3 (ft3)Vm Dry Gas Meter Volume, m3 (ft3)Vlc Volume or Mass Liquid Collected in Impingers, ml or gW Width of Duct Cross-Section at Sampling Site, m (ft....)y Dry Gas Meter Calibration Factor

nomenClature

Page 33: Isokinetic Part 1 Catalog 1-01-12 NP

66

ISOKINETIC SOURCE SAMPLING EQUIPMENT

800-882-3214 / 919-557-7300 www.apexinst.com

MERCURY SAMPLING EQUIPMENT APPENdIX K SORBENT TRAP MONITORING

METhOd 30B SORBENT TRAP RELATIVE ACCURACY TESTING AUdIT (RATA)

ISOKINETIC SAMPLING EQUIPMENT METhOd 1 dETERMINATION OF SAMPLING LOCATION ANd TRAVERSE POINTS

METhOd 2 dETERMINATION OF STACK GAS VELOCITY ANd VOLUMETRIC FLOW RATE

METhOd 3 dETERMINATION OF EXCESS AIR ANd dRY MOLECULAR WEIGhT

METhOd 4 dETERMINATION OF MOISTURE IN STACK GASES

METhOd 5 dETERMINATION OF PARTICULATE EMISSIONS FROM STATIONARY SOURCES

METhOd 5B NONSULFURIC ACId PM

METhOd 8 SULFURIC ACId MIST & SO2

METhOd 12 INORGANIC LEAd (SZL)

METhOd 13A TOTAL FLUORIdES (SIE)

METhOd 13B TOTAL FLUORIdES

METhOd 17 PARTICULATE BY IN-STACK FILTRATION

METhOd 23 dIOXINS & FURANS

METhOd 26A hYdROGEN hALIdES & hALOGENS

METhOd 29 MULTIPLE METALS

METhOd 201A PM10 EMISSIONS

METhOd 202 CONdENSABLE PARTICULATE MATTER

METhOd 202 CONdENSABLE PARTICULATE MATTER FIGURES

METhOd 206 AMMONIA

METhOd 306 hEXAVALENT ChROMIUM FROM ELECTROPLATING ANd ANOdIZING OPERATIONS

METhOd 316 FORMALdEhYdE FROM MINERAL WOOL ANd WOOL FIBERGLASS NdUSTRIES

METhOd 0010 SEMIVOLATILE ORGANIC COMPOUNdS

METhOd 0011 FORMALdEhYdE, OThER ALdEhYdES ANd KETONES

METhOd 0061 hEXAVALENT ChROMIUM

FLOW, PRESSURE & TEMPERATURE METhOd 2 dETERMINATION OF STACK GAS VELOCITY ANd VOLUMETRICFLOW RATE (TYPE S-PITOT TUBE)

GAS SAMPLING EQUIPMENT METhOd 4A STACK GAS MOISTURE (APPROX. METhOd)

METhOd 6 SULFURIC ACId MIST & SO2

METhOd 6A SULFURIC dIOXIdE, MOISTURE ANd CARBON dIOXIdE

epa reFerenCe methods

METhOd 6B SULFUR dIOXIdE ANd CARBON dIOXIdE

METhOd 11 hYdROGEN SULFIdE IN PETROLEUM REFINERY FUEL GAS STREAMS

METhOd 15A TOTAL REdUCEd SULFUR FROM PETROLEUM REFINERY SULFUR PLANTS

METhOd 16A TOTAL REdUCEd SULFUR

METhOd 18 INTEGRATEd BAG SAMPLING FOR ORGANIC COMPOUNdS

METhOd 26 hYdROGEN hALIdES & hALOGENS

METhOd 106 INTEGRATEd BAG SAMPLING FOR VINYL ChLORIdE

METhOd 308 METhANOL

METhOd 0030 VOLATILE ORGANIC COMPOUNdS (VOST)

METhOd 0031 VOLATILE ORGANIC COMPOUNdS (SMVOC OR SUPERVOST)

METhOd 0040 PRINCIPLE ORGANIC hAZARdOUS CONSTITUENTS (POhCS) USING TEdLAR® BAGS

METhOd 0051 hYdROGEN ChLORINE ANd ChLORINE

GAS ANALYSIS EQUIPMENTMEThOd 3 GAS ANALYSIS FOR ThE dETERMINATION OF dRY MOLECULAR WEIGhT

METhOd 3B GAS ANALYSIS FOR ThE dETERMINATION OF EMISSION RATE CORRECTION FACTOR OR EXCESS AIR

METhOd 7 dETERMINATION OF NITROGEN OXIdE EMISSIONS FROM STATIONARY SOURCES

IRM EQUIPMENTMEThOd 3A dETERMINATION OF OXYGEN ANd CARBON dIOXIdE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES

METhOd 6C dETERMINATION OF SULFUR dIOXIdE EMISSIONS FROM STATIONARY SOURCES

METhOd 6C dETERMINATION OF SULFUR dIOXIdE EMISSIONS FROM STATIONARY SOURCES FIGURES

METhOd 7E dETERMINATION OF NITROGEN OXIdES EMISSIONS FROM STATIONARY SOURCES METhOd 10 dETERMINATION OF CARBON MONOXIdE EMISSIONS FROM STATIONARY SOURCES

METhOd 25A dETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Page 34: Isokinetic Part 1 Catalog 1-01-12 NP

67

ISOKINETIC SOURCE SAMPLING EQUIPMENT

www.apexinst.com 800-882-3214 / 919-557-7300

Meter Calibration .............................................57Meter Calibration Equipment ...........................57Method 4 .........................................................33Method 4, Accessories ....................................33Method 5, Basic ..............................................34Method 5, Deluxe-Plus ....................................34Method 5, Compact .........................................35Method 5, Heated Filter Assembly ...................35Method 5, 5G ..................................................36Method 5, 5I ....................................................36Method 5, Alternate 5I .....................................36Method 8 .........................................................37Method 8, Accessories ....................................37Method 8, Alternate CTM-13 ...........................37Method 17, Flexible & Rigid.............................38Method 17, In-Stack Filter Assemblies ............39Method 17, Integrated In-Stack Filter Assemblies .............................................39Method 17, Glass In-Stack Filter Assemblies .............................................39Method 23, Deluxe Plus ..................................40Method 23, Sampler Kit Components ..............40Method 23, Coolant Pump Options .................40Method 23, Glassware ....................................40Method 23, Individual Accessories ..................40Method 26A, HCI ............................................41Method 26A, Accessories ................................41Method 29, Multiple Metals .............................42Method 29, Accessories ..................................42Monorails ........................................................60Method 201A, Particle Sizing ..........................44Method 201A, PM2.5 Cyclone Set ..................44Method 201A, Expanded Nozzle Set ...............44Method 201A, PM10 Cyclone Set ...................45Method 201A, PM10 & PM2.5 Cyclone Set .....45Method 201A, Cascade Impactor Set ..............46Method 201A, Particle Sizing Data Reduction WINCIDRS Software ......................................46Method 202, Dry Impinger ...............................47Method 202, Sampling Accessories ................48Method 202, Purge Accessories ......................48Method 0061, Hexavalent Chromium ..............48Nozzle Calibration ...........................................59Nozzles, Isokinetic Sampling ..........................14

Alumina ...........................................................54 Balances .........................................................55-56Ball & Socket Joint Adapters ...........................29-30Ball & Socket Joint Adapters, Impingers ..........29-30Calibration Equipment & Services ..................59Cases, Equipment ...........................................19Cases, Impinger ..............................................21Cases, Risers ..................................................21Cases, Modular Sample Frame .......................21Cases, Umbilical Gooseneck Adapter .............21Cases, Impinger Inlet Strain Relief ..................21Cases, Power Box Adapter .............................21Consoles, XC-5000 Automated Sampling ......4-5 Consoles, XC-522 / XC-572 Manual ..............6-9Consoles, XC-522 Accessories ......................8Consoles, XC-572 Accessories ......................9Consoles, XC-563 Digital Source Sampling ...43Consoles, XC-522 Accessories ......................8Consoles, XC-563 Digital Source Sampling ...10Consoles, XC-563 Audit Kit ............................10Consoles, Method 4 Source Sampling ………11Dessicator & Desiccants .................................53Dessicator & Desiccants, Vacuum Pump ........53Drierite Desiccants ..........................................54Filter Media .....................................................49-50Filter Ovens, Heated .......................................20Filter Ovens, Strain Reliefs ..............................20Filter Ovens, Socket Adapter ...........................20Filter Media, In-Stack Thimbles .......................50Glassware, Sets ..............................................22Glassware, Method 5 Sets ..............................22Glassware, Deluxe Method 5 Sets ..................23Glassware, Accessories ..................................23Glassware, Filter Assemblies/Components .....24Glassware, Individual & Accessories ...............25Glassware, Impinger Accessories ...................25Glassware, Cyclones ......................................25Glassware, Connectors ...................................26Glassware, Controlled Condensate .................26Glassware, Condensers ..................................27Glassware, Adapters .......................................27Glassware, Method 17 ....................................27Glassware, Method 202 ..................................28Glassware, Method 23 ....................................28

Nozzles, Sets..................................................14Nozzles, Oversized.........................................14Nozzles, Unions..............................................15Nozzles, Tube Nuts ........................................15Nozzles, Rings................................................15Nozzles, Vinyl Nozzle Caps ............................15Nozzles, Brushes............................................15Nozzles, Brush Sets .......................................15Nozzles, Ferrules............................................15Nozzles, Small Parts Kit .................................15Nozzles, Steel Alloys ......................................15Ontario-Hydro/Mercury ....................................43Ontario-Hydro/Mercury Accessories ................43Orifice Set .......................................................58Pitot Audit Equipment & Manometers ..............59Probe Assemblies, Method 5 ..........................16Probe Assemblies, Packing Gland .................16Probe, Method 5 Tube Heaters .......................16Probe, Replacement Pitot Tips .......................16Probe Liners ...................................................17Probe Liners, Tubing ......................................17Probe Liners, Adapters ...................................17Probe Sheaths, Method 5 Inconel ..................18Probe Sheaths, Method 5 Stainless Steel .......18Probe Sheaths, Air Cooled Method 5 ..............18Probe Sheaths, Alloy Method 5 .......................18Probe Sheaths, Blowers ..................................18Pump Assemblies, Method 5..........................12Pump Frame, Optional XF-05HW...................12Pumps, Lubricated Rotary Vane .....................12 Pumps, Lubricated Rotary Vane .....................12 Pumps, Diaphragm .........................................13Sample Lines, Heated .....................................32Sample Lines, Unheated Jumpers ..................32Sample Lines, Strain Relief .............................32Sample Recovery ............................................51Sample Recovery, Accessories .......................52Sample Recovery, Bottles ...............................52Silica Gel .........................................................54Umbilical Cables, Split Back ............................31Umbilical Cables, Classic ................................31Umbilical Cables, Classic Adapters .................31Umbilical Cables, Accessories .........................31Wet Test Meters ..............................................58

Isokinetic

Page 35: Isokinetic Part 1 Catalog 1-01-12 NP

TERMS ANd CONdITIONS

PRICES ANd TERMSOur prices are subject to change without notice. The price in effect when we receive your order will apply. All prices are Ex Works Holly Springs, North Carolina. We will be pleased to furnish quotations by phone, fax or e-mail. Terms of payment are Net 30 days with established credit, or by Visa/MasterCard/American Express at time of order. Invoices over 30 days past due are subject to 1.5% per month finance charge.

CONFIRMING ORdERSPlease make sure that all confirming orders are clearly marked to avoid duplicate orders.

ShIPMENTS ANd dELIVERYUnless otherwise instructed, shipments are made as soon as possible after receipt of order by method of transportation which in our judgement will be most satisfactory. Freight charges are prepaid and added to the invoice. The right is reserved to make partial shipments where delays beyond our control may delay a portion of the order.

EXPORT PROCESSING ANd PRICINGPrices do not include customs and duty charges, freight, insurance, export fees, bank wire transaction fees or any additional handling fees.

RETURNEd ITEMSAuthorization must be obtained from us before returning any goods. When requesting return authorization, please advise reason for return, date of purchase, your P.O. number and our invoice number. Equipment produced to special specifications are not returnable. All returns must be shipped freight prepaid at the purchasers expense and are subject to a restocking fee.

LIMITEd WARRANTYAPEX INSTRUMENTS, INC. warrants products to be free from defects in workmanship for a period of one year from date of delivery. The sole and exclusive remedy for defective goods shall be to repair or replace defective parts or payment price of the goods for which damages are claimed at APEX INSTRUMENTS, INC.’s option. Freight for return of defective items will be at the sole discretion of APEX INSTRUMENTS, INC. Except as described in our guarantee, there are no express warranties or implied warranties including, but not limited to, merchantability and fitness for a particular purpose. APEX INSTRUMENTS, INC. shall not be subject to and disclaims: (1) any other obligations or liabilities arising out of breach of contract or warranty, (2) any obligations whatsoever arising from tort claims (including negligence and strict liability) or arising under other theories of law with respect to products sold or services rendered by APEX INSTRUMENTS, INC., or any undertakings, acts or omissions relating thereto, and (3) all consequential, incidental and contingent damages whatsoever.

dESIGN ChANGESDesign changes are made from time to time. Some items may differ slightly from catalog illustrations or descriptions. Changes are made in the interest of better performance and quicker delivery.

ACCEPTANCE OF TERMS ANd CONdITIONSAPEX INSTRUMENTS, INC. sells products only under foregoing terms and conditions and will not be bound to terms and conditions stated by any purchaser in any offer, acceptance or other contractual document. Placing an order or accepting delivery of products constitutes acceptance of terms and conditions.

Great care has been taken in preparation of this literature, however, we cannot be responsible for any omissions or typographical errors.

204 Technology Park LaneFuquay-Varina, North Carolina 27526, U.S.A.

Telephone: 919-557-7300In U.S. Call: 800-882-3214

Fax: 919-557-7110Email: [email protected]

APEx INSTrUMENTS, INC.Solutions for Source Sampling EquipmentApex Instruments is a world leader in the manufacture, design and distribution of source sampling equipment. Our products are used in a wide variety of sampling scenarios. Our equipment complies with emissions measurement standards for stationary combustion sources in accordance with US EPA guidelines. We are located approximately 20 miles from the United States Environmental Protection Agency in Research Triangle Park, N.C. Our goal is to provide you with the proper, well engineered equipment in order for your job to run smoothly and have consistent, accurate and reliable results.

teChniCal serViCesApex Instruments understands the needs and high demands of the individuals working in the source sampling industry. The primary end users of our equipment consist of government agencies, consulting firms and private industries throughout North America and in 50 countries around the globe. Our knowledgeable staff includes many skilled industry professionals, stack testers and chemists. They all will help you make important decisions regarding your specific ap-plication needs.

CaliBration serViCesApex Instruments offers dedicated, climate controlled, precision calibration services for a variety of measuring instruments. This includes gas meters, orifices and pitot tubes to help keep all your calibration equipment up-to-date. Our trained staff will utilize the reliable calibration equipment and tools such as NIST Certified Bell Prover, wet test meters, electronic flow calibrators and wind tunnels. We offer a certification of calibration when requested.

Custom FaBriCation and assemBlYApex Instruments’ custom-designed facility was built in 2005. The warehouse layout provides a smooth flow for the assembly and fabrication departments. We can design, build and expedite all equipment orders quickly through our in-house engineering, production and welding departments. Apex continues with their steady commitment to quality in compliance testing, by consistently designing and developing reliable source sampling equipment. We follow guidelines set by U.S. EPA Reference Methods and always keeping the genuine needs of the stack samplers in mind.

aWardsApex Instruments recently received the (SHARP) Safety and Health Achievement Award from the NC (DOL) Department of Labor. This program recognizes small to medium size businesses that establish and maintain effective safety standards and health programs. We were also ranked in the top 500 by Inc. Magazine as being one of the fastest growing privately held companies.

Page 36: Isokinetic Part 1 Catalog 1-01-12 NP

www.apexinst.com

XC-522

XC-5000

XC-40

Publication:Date Issued:

PEC-Isokinetic1-01-12

IsokInetIcequIpmentcatalog

Distributed by: