isorolls self adh. t.d.s 2008 eng
DESCRIPTION
brochureTRANSCRIPT
& SBI
Property Technical Data Test Method Lab/Test Reports
Density (60 – 75) Kgr/m3 EN 1602 or pr EN13470 self monitoringTensile strength >0,15 MPa EN ISO 1798 self monitoringElongation at break >150% EN ISO 1798 self monitoringLength & width Length ±1,5%
Width ±2%Thickness 6mm ±1mm
10,13 & 19mm ±1,5mm25,32,36 & 40mm ±2mm
0ºC 0,035W/mK20ºC 0,037W/mK40ºC 0,040W/mK
W. V. diffusion resistance (µ)
≥7000 EN 13469 self monitoring
Corrosion Resistance Water soluble ions in accordance DIN 1988 - 7 or prEN 13823 MPA
Fire rating C / s3 / d0 EN 13823 & EN ISO 11945-2
TÜV Nord Baltik Ltd TNO,Swedcert
M1 NF P 92-501 NF EN ISO 4589-2
LNE,Siemens Axiva GmbH
Class 0 BS 476 p.6 & p.7 Warrington Fire Research
Classe 1 UNI 8457 LAPI
Low flame spreadIMO RES.MSC
61(67)FTP code,Annex 1,Part 5
Siemens Axiva GmbH supervised by Bureau
Veritas MARINE DivisionNoise reduction Up to 30dB DIN 4109Dimensional Stability 1,5 - 3% EN 1604 self monitoringOil &grease resistance Very good ASTM D 471 self monitoringCFCOdor
Film thickness LDPE 70µm
AdhesivePolyester net construction
4 x 1 plain
Adhesion 470 gr/cm
Description
Application
Operating temperatures
3i International - Innovative - Insulation S.A. Tel. No.: + 30-22620-71867 , Fax No.: +30-22620-72006Plant: 68th Km Nat. Rd Athens - Lamia 34100 Ritsona Halkida - GREECE e-mail: [email protected] http: www.isopipe.eu
ISOROLLS - ISOSHEETS properties
self monitoring
Self Adhesive
Free
TECHNICAL DATA SHEET
Neutral
Description of productFlexible elastomeric insulation based on synthetic rubber, in flat sheet or rolls form, having adhered to one side a double sided self adhesive with an easy release liner.Ductwork, large pipes, tanks, irregular surfaces, cold or hot equipment when easy handling and fast installation is required.
Min. Temperature -40° C - Max. Temperature +85° C.
Self Adhesive Technical Data
Aquous dispersion of natural & synthetic latex
self monitoring
self monitoringEN 12667
EN822
The written figures are these that have been measured in our laboratory, under typical conditions. They can be modified without prior notice. You are kindly requested to assert their validity before any special usage.
Thermal Conductivity (λ)
EN 823