issue 3 operating instructions · 2018-05-08 · operating instructions to zero the gauge if the...

1
Attach Gauge to Tester 1. Remove dust cap from gauge coupler 2. Remove dust cap from tester coupler 3. Pull back ring on tester coupler and insert gauge coupler. Release ring to complete coupling. Operate Gauge in ‘Normal rise and fall’ mode Press button to switch gauge on to ‘Normal rise and fall mode’. This will give a load reading, rising as the operating handle on the tester is turned clockwise. By turning the handle anti-clockwise the load will decrease and show the reading decreasing. Press to switch off gauge when finished. Hydrajaws Digital Gauge Operating Instructions To Zero the gauge If the gauge is reading a small amount (0.3 for example) when no load is applied - use the following instructions to re-set the display to zero. First release any pressure held in the Hydraulic Coupler by pushing in the pin at the base of the coupler. To preserve battery life it is recommended the backlight is used only when needed and is switched off when the gauge is not in use. CAUTION: DO NOT ZERO THE GAUGE WHEN IT IS UNDER LOAD. The gauge should not be loaded above its maximum load capacity as permanent damage will occur. CAUTION! Activating the backlight 1. Press AND HOLD the button to switch the backlight on and off 1. Press AND HOLD the button to zero the gauge Low battery When the battery is low an indicator will appear on screen. The battery is changed by unscrewing the cover on the back of the gauge using the 2mm allen key provided. Please replace with a 6LR 61 9V battery and fit as shown below. To prevent damage to the contacts, always remove the battery as shown below. Operate Gauge in ‘Peak Hold’ mode 1. Press button to switch gauge on 2. Press to activate ‘Peak Hold’ mode. This will be indicated by an arrow on screen. Gauge is now in peak hold mode and will display the maximum load achieved and retain this even when the load has decreased. To turn ‘Peak Hold’ mode on and off use the button. Note: When first turned on, a bluetooth symbol will flash in the right hand side of the screen. This is used for the Bluetooth Digital enabled version of the gauge and will normally stop flashing after 60 seconds. Issue 3 Remove battery Fit battery 2 3 1 2 1 3 www.hydrajaws.co.uk email: [email protected] Hydrajaws Ltd., 20/21 The Courtyard, Gorsey Lane, Coleshill, Birmingham B46 1JA Tel: +44 (0)1675 430 370 Fax: +44 (0)1675 465 950 MAKE SURE IT’S SECURE

Upload: others

Post on 11-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Issue 3 Operating Instructions · 2018-05-08 · Operating Instructions To Zero the gauge If the gauge is reading a small amount (0.3 for example) when no load is applied - use the

Attach Gauge to Tester1. Remove dust cap from gauge coupler2. Remove dust cap from tester coupler3. Pull back ring on tester coupler and insert gauge coupler. Release ring to complete coupling.

Operate Gauge in ‘Normal rise and fall’ mode

Press button to switch gauge on to ‘Normal rise and fall mode’. This will give a load reading, rising as the operating handle on the tester is turned clockwise. By turning the handle anti-clockwise the load will decrease and show the reading decreasing.Press to switch off gauge when finished.

Hydrajaws Digital Gauge Operating Instructions

To Zero the gaugeIf the gauge is reading a small amount (0.3 for example) when no load is applied - use the following instructions to re-set the display to zero.

First release any pressure held in the Hydraulic Coupler by pushing in the pin at the base of the coupler.

To preserve battery life it is recommended the backlight is used only when needed and is switched off when the gauge is not in use.

CAUTION:DO NOT ZERO THE GAUGE WHEN IT IS UNDER LOAD.

The gauge should not be loaded above its maximum load capacity as permanent damage will occur.

CAUTION!

Activating the backlight

1. Press AND HOLD the button to switch the backlight on and off

1. Press AND HOLD the button to zero the gauge

Low batteryWhen the battery is low an indicator will appear on screen.The battery is changed by unscrewing the cover on the back of the gauge using the 2mm allen key provided.Please replace with a 6LR 61 9V battery and fit as shown below.

To prevent damage to the contacts, always remove the battery as shown below.

Operate Gauge in ‘Peak Hold’ mode

1. Press button to switch gauge on

2. Press to activate ‘Peak Hold’ mode. This will be indicated by an arrow on screen.

Gauge is now in peak hold mode and will display the maximum load achieved and retain this even when the load has decreased.

To turn ‘Peak Hold’ mode on and off use the button.

Note: When first turned on, a bluetooth symbol will flash in the right hand side of the screen. This is used for the Bluetooth Digital enabled version of the gauge and will normally stop flashing after 60 seconds.

Issue 3

Remove battery

Fit battery2 1

3

2 31

TO AVOID DAMAGE INSERT

BATTERY AS SHOWN

2 13

2 31

TO AVOID DAMAGE INSERT

BATTERY AS SHOWN

www.hydrajaws.co.uk email: [email protected]

Hydrajaws Ltd., 20/21 The Courtyard, Gorsey Lane, Coleshill, Birmingham B46 1JATel: +44 (0)1675 430 370 Fax: +44 (0)1675 465 950

MAKE SURE IT’S SECURE

Est 1988

Est 1988 Est 1988

YEARS IN BUSINESS

YEARS IN BUSINESS

OVER

YEARS IN BUSINESS

YEARS IN BUSINESS

IN BUSINESSYEARS IN BUSINESS

YEARS IN BUSINESS

IN BUSINESS IN BUSINESS