issued by rpp-wtp pdc • page 1 of~ 24590-law-m6n-lvp- · placed : nov 13, 2015 , 3:46 pm ,plaoed...
TRANSCRIPT
Issued byRPP-WTP PDC
Please note that source, special nuclear, and byproduct materials, as defined in the Atomic Energy Act of 1954 (AEA) are regulated at the U. S. Department of Energy (DOE) facilities exclusively by DOE acting pursuant to its AEA authority. DOE asserts that pursuant to AEA, it has sole and exclusive responsibility and authority to regulate source, special nuclear, and byproduct materials at DOE-owned nuclear facilities. Information contained herein on radionuclides is provided for process description purposes only.
• Page 1 of~
Drawing Change Notice - CHANGE DOCUMENT NO. 24590-LAW-M6N-LVP-00138
JOB NO. I TITLE FOR CHANGE NOTICE 24590 Add Isolations and New Transfer Line to the LAW L VP System for DFLAW Operations
DOCUMENT NUMBER REV DOCUMENT NUMBER REV
24590-LAW-M6-LVP-00002005 0 24590-LAW-M6VX-L VP-00002005 0
24590-LAW-M6WX-L VP-00002005 0
PART OF DESIGN CHANGE PACKAGE (DCP)? D Yes ~ No DCP No.: N/A Rev:
NOTE: The eight-week walk down has not been completed , therefore a DCP is not required.
JUSTIFICATION FOR CHANGE
Modifications to isolate transfer lines to the PT Facility and add new transfer line going out to the new Effluent Management Facility (EMF) for DFLAW operations.
Supersedes Change Document D Yes C8J No
ECN Needed C8l Yes D No ECN No.: 24590-LAW-M6N-LVP-00138-ECN
REQUIREMENTS REVIEW
Client Approval Required D Yes C8J No I interface Resolution Required• D Yes C8J No
Address any 'yes" answers in the description
DESCRIPTION OF CHANGE
Revise P&ID 24590-LAW-M6-LVP-00002005 (Coordinates B-D, 2-4) as shown on page 2 and 3:
Add new transfer line to the Effluent Management Facility (EMF). Add globe valve, spectacle blind , and bleed valve to PT transfer lines for positive isolation whether in DFLAW operations or full WTP operations . Add AEA note and additional ADR No. 24590-WTP-ADR-M-16-0001 , Rev. 0.
Modify valve list 24590-LAW-M6VX-LVP-00002005 as show on page 4.
Modify line list 24590-LAW-M6WX-LVP-00002005 as shown on page 4.
Note: MS In-l ine component list 24590-LAW-M6UX-LVP-00002005, Rev. 0, for P&ID 24590-LAW-M6-LVP-00002005, is issued concurrently with this DCN to support the addition of the Spectacle Blinds, LVP-BLND-00006 and LVP-BLND-00009.
ORIGINATOR CHECKER Checked Mechanical Systems - Jordan Stromstad s?!!~'s?ro!!?f..,,om:~"r Ken Varma By; Ken Varma . kjvarma
Org Name: DFLAW MS Org Name: OFLAW MS
Placed: Nov 13, 2015, 3:46 pm ,Plaoed: Jan 13, 2016, 12:48pm
Approval(s)
LAW C&I EGS Dennis Yard LAW MS EGS Prabhu Rajagopalan
~ Date (inserted by final approver): 'f 2 - lb - /~
Please note that source , special nuclear, and byproduct materials, as defined in the
Atomic Energy Act of 1954 (AEA) are regulated at the U.S. Department of Energy
(DOE) facilities exclusively by DOE acting pursuant to its AEA authority. DOE
asserts that pursuant to AEA, it has sole and exclusive responsibility and authority
to regulate source , special nuclear, and byproduct materials at DOE-owned nuclear
facilities. Information contained herein on radionuclides is provided for process
description purposes only.
24590-G04B-F00006 Rev 44 (Revised 6/30/2015)
v
Ref: 24590-WTP-3DP-G04T-00901
I
Before After
24590-LAW-M6-LVP-00002005 Coordinates B-D, 2-4
Drawing Change NoticePage 2 of 4
CHANGE DOCUMENT NO. 24590-LAW-M6N-LVP-00138
------------7
V
96
I I
E;(Vli ~ ? .._,- >
" n []_ 0 > 0 ----'
3/8" TUBING ISA
L VP-ZY-00061-S11M-01
L VP-ZY-00017-S11M-03
S11M
L VP-ZY-00062-S11M-01
L VP ZY-00015 S11M-03
S11M
w N
0 0
> []_
> ----'
W31A
r--N 0 0
> []_
> ----'
W31A
L VP ZY-00043-W31A-03 RLD-VSL 00017B PTF-M6-PWD-00058
NOTE 6
LVP-ZY-00042-W31A-03 RLD-VSL-00017A PTF-M6-PWD-00058
NOTE 6
F8
E8
-,
YV 095
I LVP-lY-00174-SIIM-01
LVP-V-72386 NO FOR DFLAW
NC FOR WTP OPERATION S11M
I LVP-ZY-00062-SIIM-01
~ ro ~ N ~
> "-~ 1 LVP-ZY-00172-W31A-03
NOTES 6
W31A
DEP-VSL -00004A/B B0F -M6-RLD-00012001
24590-LAW-M6-LVP-00002005
Coordinates B-1 and B-2
Drawing Change NoticePage 3 of 4
CHANGE DOCUMENT NO. 24590-LAW-M6N-LVP-00138
ADD
MODIFY
ADD ABOVE TITLE BLOCK
PLEASE NOTE THAT SOURCE, SPECIAL NUCLEAR AND BYPRODUCT MATERIALS, AS DEFINED IN THE ATOMIC ENERGY ACT OF 1954 (AEA) ARE REGULATED AT THE U.S. DEPARTMENT OF ENERGY (DOE) FACILITIES EX CL US IVEL Y BY DOE ACTING PURSUANT TO ITS AEA AUTHORITY DOE ASSERTS, THAT PURSUANT TO THE AEA IT HAS SOLE AND EXCLUSIVE RESPONSIBILITY AND AUTHORITY TO REGULATE SOURCE, SPECIAL NUCLEAR AND BYPRODUCT MATERIALS AT DOE -OWNED NUCLEAR FACILITIES. INFORMATION CONT AI NED HEREIN ON RADIONUCLIDES IS PROVIDED FOR PROCESS DESCRIPTION PURPOSES ONLY.
!
REFERENCES:
1. 24590-LAW-3YD-LOP-00001, SYSTEM DESCRIPTION FOR THE LAW PRIMARY OFFGAS CLOP) AND SECONDARY OFFGAS/VESSEL VENT CL VP) SYSTEMS.
I]' 2. 24590-LAW-ADR-M-02-023 REV 4, LAW SECONDARY OFFGAS ~ VESSEL VENT PROCESS SYSTEM (LVP)_
3. 24590-WTP-ADR-M-16-0001 REV 0, ALARA DESIGN REVIEW FOR BOF DEP SYSTEM.
CONTEN T '"'V~~ ~..._,---.o,-~~ ,e-...__J YESC]NO REV:
MS Line List – 24590-LAW-M6WX-LVP-00002005 Add per this DCN INSULATION NORMAL MAXIMUM DESIGN LEAK TEST TAG NUMBER ORIGINATING
DESIGN DOC QL SEISMIC SAFETY SSC
CHAR CODE THICK
NESS (IN)
DWP PRES (PSIG)
TEMP (F)
PRES (PSIG)
TEMP (F)
PRES (PSIG)
TEMP (F)
SHOP PAINT CODE
TYPE PRES (PSIG)
NOTES BY VEND
REMARKS
24590-LAW-PP-LVP-ZY-00015-S11M-003/4-02B02 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 44 160 60 160 N/A H 90 NO DRAIN
24590-LAW-PP-LVP-ZY-00017-S11M-003/4-02B02 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 44 160 60 160 N/A H 90 NO DRAIN
24590-LAW-PP-LVP-ZY-00017-S11M-03-03 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 44 160 60 160 N/A H 90 NO Piping is required to have insulation regardless of accessibility
24590-LAW-PP-LVP-ZY-00172-W31A-03-01 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 109 160 150 160 N/A H 225 NO
CCN 054843 details insulation and coating requirements for the coaxial lines. The six inch S32B encasement pipe shall be pneumatically tested to 55 psig. Shop paint code per 24590-WTP-3PS-AFPS-T0001. CCN 275008 (14-WTP-0224) documents ORP-WTP approval for Pneumatic Testing of the encasement pipe.
24590-LAW-PP-LVP-ZY-00173-S11M-03-01 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 109 160 150 160 N/A H 225 NO Piping is required to have insulation regardless of accessibility.
24590-LAW-PP-LVP-ZY-00174-S11M-01-01 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 0 150 50 160 50 160 N/A Pn 55 NO Piping is required to have insulation regardless of accessibility. CCN 275008 (14-WTP-0224) documents ORP-WTP approval for Pneumatic Testing.
Modify per this DCN Before
INSULATION NORMAL MAXIMUM DESIGN LEAK TEST TAG NUMBER ORIGINATING
DESIGN DOC QL SEISMIC SAFETY SSC
CHAR CODE THICK
NESS (IN)
DWP PRES (PSIG)
TEMP (F)
PRES (PSIG)
TEMP (F)
PRES (PSIG)
TEMP (F)
SHOP PAINT CODE
TYPE PRES (PSIG)
NOTES BY VEND
REMARKS
24590-LAW-PP-LVP-ZY-00017-S11M-03-02 24590-LAW-M6-LVP-00002005 CM SC-IV NON-
SAFETY NONE PP 1 YES 42 150 44 160 60 160 N/A H 90 NO Piping is required to have insulation regardless of accessibility After 24590-LAW-PP-LVP-ZY-00017-S11M-03-02 24590-LAW-M6-LVP-
00002005 CM SC-IV NON-SAFETY NONE PP 1 YES 42 150 109 160 150 160 N/A H 225 NO Piping is required to have insulation regardless of accessibility
MS Valve List – 24590-LAW-M6VX-LVP-00002005, Rev 0 Add per this DCN TAG NUMBER ORIGINATING
DESIGN DOC QL SEISMIC SAFETY SSC
CHAR VALVE SIZE (IN)
VALVE TYPE
ATTACHED TO DESIGN PRES(PSIG)
DESIGN TEMP(F)
BY VEND
REMARKS
24590-LAW-PV-LVP-V-72385 24590-LAW-M6-LVP-00002005 CM SC-IV NON-SAFETY NONE 3 BALL 24590-LAW-PP-LVP-ZY-00017-S11M-03-02 60 160 NO -BY PD
24590-LAW-PV-LVP-V-72386 24590-LAW-M6-LVP-00002005 CM SC-IV NON-SAFETY NONE 3 BALL 24590-LAW-PP-LVP-ZY-00173-S11M-03-01 150 160 NO -BY PD
24590-LAW-PV-LVP-V-72387 24590-LAW-M6-LVP-00002005 CM SC-IV NON-SAFETY NONE 1 GATE 24590-LAW-PP-LVP-ZY-00174-S11M-01-01 50 160 NO -BY PD
24590-LAW-PV-LVP-V-72884 24590-LAW-M6-LVP-00002005 CM SC-IV NON-SAFETY NONE 0.75 GATE 24590-LAW-PP-LVP-ZY-00017-S11M-003/4-02B02 60 160 NO -BY PD
24590-LAW-PV-LVP-V-72886 24590-LAW-M6-LVP-00002005 CM SC-IV NON-SAFETY NONE 0.75 GATE 24590-LAW-PP-LVP-ZY-00015-S11M-003/4-02B02 60 160 NO -BY PD
Drawing Change NoticePage 4 of 4
CHANGE DOCUMENT NO. 24590-LAW-M6N-LVP-00138
_J _J
_J _J _J -- - - - - - - - - - - - - - - - -- d :=J- :-::J-- - - - - - - - - - - -
I 1- 1 - I - 1- 1- 1- 1- 1- 1- 1 1- 1 1- 1- 1- I- I 1- 1 - -
- - =--- -I - - - - - - - - - - 1- - -
- Id :=J :_J :-::J :-::J-- - - - - - - - - -
~ ~ ~ d ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ -
I _J _J _J _J _J
l_jl
I _J _J _J
I :=_J - -- - - - :=_J -- - -- - - - - -
- - -- - - - - -
- - - - - - - - -
- - - - - - - - -