issued for construction 06/03/2016 · 2016-06-08 · fec dw conference 104 office 105 office 106...
TRANSCRIPT
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A001
16030.ID
COVER SHEET
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
ISSUED FOR CONSTRUCTION 06/03/2016
BANK OF TENNESSEE12920 LEBANON ROADMT. JULIET, TN 37122
THIS IS A DESIGN/BUILD PROJECT. GENERAL CONTRACTOR SHALL PROVIDE MECHANICAL,ELECTRICAL AND PLUMBING DRAWINGS AS NEEDED FOR NECESSARY CODES COMPLIANCE.
No. REVISED DATE
PROJECT TEAMABBREVIATIONS
MATERIAL IN SECTION
VICINITY MAP
MATERIALS IN ELEVATION
GRAPHIC SYMBOLS GENERAL NOTES INDEX OF DRAWINGS
BUILDING REVIEW DATA
L
L
ABC ABOVE COUNTER
ADA AMERICANS WITH DISABILITIES
ACT
ADJ ADJUSTABLE
A/C AIR CONDITIONER
ALUM ALUMINUM
A.L. ALUMINUM
BM BEAM
BP BASE POWER
BLDG BUILDING
CAB CABINET
C CENTERLINE
CLG CEILING
CLNG CEILING
CEM CEMENT
CJ CONTROL JOINT
CL CLEAR
CLR CLEAR
COL COLUMN
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCT (ION)
CONT CONTINUOUS
CTR CENTER
DIA DIAMETER
DN DOWN (RAMP OR STAIRS)
DS DOWNSPOUT
DWG DRAWING
EA EACH
E EAST
ELEC ELECTRIC (AL)
EL ELEVATION
ELEV ELEVATION
EJ EXPANSION JOINT
EQ EQUAL
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FT FEET / FOOT
FIN FINISH
FIN FL FINISH FLOOR
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FLUOR FLUORESCENT
FOS FACE OF STUD / FACE OF SLAB
FTG FOOTING
F.V. FIELD VERIFY
GA GAUGE
GYP GYPSUM
GYP BD GYPSUM BOARD
HD HEAVY DUTY
HM HOLLOW METAL
HOR HORIZONTAL
HORIZ HORIZONTAL
IN INCH
INSUL INSULATION
INT INTERIOR
LAM LAMINATE
MANUF MANUFACTURER
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MFG MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
MT METAL THRESHOLD
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
O.F.C.I. OWNER FURNISHED CONTRACTOR
INSTALLED
O.F.O.I OWNER FURNISHED OWNER
INSTALLED
OFD OVERFLOW ROOF DRAIN
OPP OPPOSITE
P PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS LAM PLASTIC LAMINATE
PT PAINT(ED)
PTD PAINTED
PVC POLYVINYL CHLORIDE
P.T. PRESSURE TREATED
RECP RECEPTACLE
RE: REFERENCE
REF REFERENCE
REQ REQUIRED
REV REVISED / REVISION
RD ROOF DRAIN
SECT SECTION
SHT SHEET
S SOUTH
SQ SQUARE
SS SOLID SURFACE
S.S. STAINLESS STEEL
STL STEEL
T.O.S. TOP OF STEEL
TSTL TOP OF STEEL
TYP TYPICAL
UC REF UNDER COUNTER REF.
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITE TILE
W WEST
W / WITH
W / O WITHOUT
WD WOOD
DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THEARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.
THE CONTRACTOR SHALL COORDINATE BETWEEN TRADES TO ENSURE PROPER AND EFFICIENT SEQUENCE OF THE WORK.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB CONDITIONS AND REPORT TO ARCHITECT/ENGINEER ANY DISCREPANCIES OR OMISSIONS WHICHWOULD INTERFERE WITH COMPLETION OF THE WORK.
DIMENSIONS SHOWN ON THE FLOOR PLANS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. UNLESS OTHERWISE NOTED.
THE APPLICABLE CODES LISTED ON THE COVER SHEET ARE PROVIDED AS A CONVENIENCE TO THE CONTRACTOR AND ARE NOT TO BE CONSIDERED ALLINCLUSIVE OF CODES AND REGULATIONS THAT MAY APPLY TO THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION. THECONTRACTOR SHALL BE RESPONSIBLE FOR FILING AND SECURING ALL NECESSARY PERMITS, APPROVALS, ETC. FOR ALL TRADES. COPIES OF EACH SHALL BEFURNISHED TO THE ARCHITECT AND OWNER.
ALL ITEMS REQUIRING A COLOR SELECTION SHALL HAVE STANDARD SAMPLES OF THE ACTUAL MATERIAL SUBMITTED TO THE ARCHITECT FOR SELECTION ANDAPPROVAL. COLOR SELECTION FROM MAGAZINE COLOR CHARTS IS NOT ACCEPTABLE.
THE CONTRACTOR SHALL OVERSEE CLEANING AND ENSURE THAT THE PREMISES ARE MAINTAINED FREE OF HAZARDOUS DEBRIS DURING CONSTRUCTION.REPAIR, PATCH, TOUCH-UP OR REPLACE MARRED SURFACES AND MAINTAIN CLEANING UNTIL OCCUPIED BY TENANT.
RECESSED ITEMS GREATER THAN 16 SQUARE INCHES IN RATED WALLS, INCLUDING BUT NOT LIMITED TO ELECTRICAL PANELS, ELECTRICAL BOXES, FIREEXTINGUISHER CABINETS, ETC. SHALL BE ENCLOSED IN A FIRECODE GYPSUM BOARD FIVE-SIDED BOX TO MAINTAIN RATING.
CASEWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO FABRICATION AND INSTALLATION.
PROVIDE SCHEDULED FINISH BASE ALONG THE BOTTOM OF ALL EXPOSED FRONTS, BACKS, SIDES AND ENDS OF FIXED CASEWORK, VERTICAL SUPPORTS, KNEESPACES, ETC. UNLESS OTHERWISE NOTED ON DRAWINGS.
CAULK AT JUNCTURE OF INTERIOR FACES OF DOOR FRAMES, VIEW WINDOW FRAMES, EXTERIOR WINDOW FRAMES, CABINET WORK, AND CASEWORK WITHADJACENT MATERIALS EVEN THOUGH JOINT MAY NOT BE VISIBLE.
PROVIDE FIRE-TREATED WOOD BLOCKING FOR ALL WALL-MOUNTED FIXTURES SUCH AS GRAB BARS, EQUIPMENT, TOILET ACCESSORIES AND FIXTURES.
CONCEAL ALL PIPING IN WALLS AND CEILINGS. WHERE PIPING IS TOO LARGE, CONTRACTOR SHALL INCREASE WALL SECTION OR PROVIDE FURRING OUT TO THEMINIMUM NECESSARY TO CONCEAL PIPING. INCREASED WALL THICKNESS SHALL CAUSE NO SURFACE IRREGULARITIES IN WALL PLANE AND SHALL EXTENDFROM WALL CORNER TO WALL CORNER.
WALL MOUNTED SINKS AND LAVATORIES SHALL BE MOUNTED SO THAT THERE WILL BE 4 INCHES MINIMUM CLEARANCE BETWEEN SIDE OF SINK AND FACE OFADJACENT WALL, CASEWORK, FIXED EQUIPMENT, ETC.
TOILETS SHALL BE MOUNTED SO THAT THERE IS 1'-6" BETWEEN FACE OF ADJACENT WALL AND CENTERLINE OF TOILET FIXTURE.
THE CONSTRUCTION DOCUMENT DRAWINGS ARE GENERALLY DIAGRAMMATIC AS RELATING TO THE ROUTING OF MECHANICAL DUCTING, ELECTRICALWIRING, AND PLUMBING PIPING. THE CONTRACTOR SHALL COORDINATE ALL TRADES DURING CONSTRUCTION AND MINOR OFFSETS AND ADJUSTMENTSSHALL BE PROVIDED WHERE REQUIRED AT NO ADDITIONAL COST TO THE OWNER.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
ARCHITECT CLIENT
GENERAL CONTRACTOR
BANK OF TENNESSEE10431 WALLACE ALLEY STREETKINGSPORT, TN 37663P: (423) 279-2561
OLYMPIAN CONSTRUCTION CO.189 CENTER POINT ROAD SOUTHHENDERSONVILLE, TN 37075P: (615) 248-8843
SOUTHEAST VENTURE, LLC4011 ARMORY OAKS DRIVENASHVILLE, TN 37204P: (615) 833-8716
EXISTING BUILDING INFORMATION:
CITY: MT. JULIET, TENNESSEE
THIS PROJECT IS AN EXISTING 1 STORY BUILDING.
OCCUPANCY: BUSINESS -NON-SPRINKLERED
2012 INTERNATIONAL BUILDING CODE*2012 INTERNATIONAL PLUMBING CODE *2012 INTERNATIONAL MECHANICAL CODE*2012INTERNATIONAL FUEL GAS CODE*2012 INTERNATIONAL FIRE CODE*2012 LIFE SAFETY CODE (NFPA 101)2012 INTERNATIONAL ENERGY CONSERVATION CODE*2009 ICC/ANSI-117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
* NFPA WITH LOCAL AMENDMENTS
APPLICABLE CODES (PLUS LOCAL AMENDMENTS):
1
1
2
G1C1
H1
1A
1A
7/A7.1
E
D
A-1
A270
TYPE B
102
1A301
1A301
21
A201
2A201
SIM.
9'-0"
INDICATES DETAILDRAWING NUMBER
INDICATES ON WHATSHEET DRAWING ISSHOWN
INDICATES ELEVATIONDRAWING NUMBER
INDICATES ON WHATSHEET DRAWING ISSHOWN
FILLED IN TAG INDICATESACTIVE ELEVATION
INDICATES ON WHATSHEET DRAWING ISSHOWN
INDICATES DETAILDRAWING NUMBER
SIM.: SIMILAR TO DETAILO.H.: OPPOSITE HAND
DOORNUMBER
UNITDESIGNATION
TYPE
ACCESSIBLEUNIT TYPE
SHEETNUMBER
FOR UNIT
UNITPOSTALNUMBER
A10
1ROOMNAME
101
EXTERIORELEVATION TARGETS
SECTION TAG
INTERIOR ELEVATIONMARKS
MILLWORKELEVATION TAG
DETAIL TAG
COLUMN GRIDS
DOOR AND ATTACHEDTAG
ROOM MARK
FRAME TYPE TAG
GLAZING KEYGLAZING TYPE TAG
DEMOLITION NOTE
EQUIPMENT KEY
KEYNOTE
REVISION MARKELEMENTS TO ALIGNCEILING HEIGHT
ABOVE FINISH FLOOR WALL TYPE TAG
DATUM OR SPOTELEVATION
UNIT TYPE TAG
ALIGN
BRICK
PRECAST
VISION GLASS
STONE
FINISH WOOD
ROUGH WOOD
BATT INSULATION
RIGID INSULATION
CERAMIC TILE
GYPSUM BOARD
METAL (SMALL SCALE)
PLYWOOD
STRUCTURALCONCRETE
ACOUSTICAL TILE
RESILIENT FLOORING
TILE ON CONCRETE
PARTICALBOARD
BRICK
THIS IS A DESIGN/BUILD PROJECT. GENERALCONTRACTOR SHALL PROVIDE MECHANICAL,ELECTRICAL AND PLUMBING DRAWINGS ASNEEDED FOR NECESSARY CODES COMPLIANCE.
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A002
16030.ID
GENERAL NOTES ANDINDEX
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
SHEET INFORMATION RELEASE# NAME ORIGINAL REV LATEST
A001 COVER SHEET 06/03/2016A002 GENERAL NOTES AND INDEX 06/03/2016A100 LIFE SAFETY PLAN AND ACCESSIBILITY STANDARDS 06/03/2016A200 NOTED FLOOR PLAN AND PARTITION TYPES 06/03/2016A220 CODED DOOR PLAN AND SCHEDULE 06/03/2016A600 REFLECTED CEILING PLAN 06/03/2016A700 ENLARGED TOILET PLAN AND ELEVATIONS 06/03/2016A800 ENLARGED PLANS AND ELEVATIONS 06/03/2016A900 POWER AND DATA LOCATION PLAN 06/03/2016F100 FINISH SCHEDULE 06/03/2016F200 FINISH PLAN 06/03/2016
No. REVISED DATE
FEC
DW
CONFERENCE
104OFFICE
105
OFFICE
106
OFFICE
107
ACCESSIBLERESTROOM
103
COPY/WORK
102
BISTRO
101
OPEN OFFICE
100
CORRIDOR
108
17' - 6"
EXISTING FEC
REQ. MINIMUM EXIT SEPARATION
57' - 2" / 2 = 28' - 7"
ACTUAL EXIT SEPARATION
31' - 11"
I.T.
102A
ARCHITECTURAL ZONING AND LIFE SAFETY CODE ANALYSIS
APPLICABLE CODES:
CITY OF MT. JULIET::2012 INTERNATIONAL BUILDING CODE*2012 INTERNATIONAL MECHANICAL CODE*2012 INTERNATIONAL PLUMBING CODE *
2012 INTERNATIONAL FUEL GAS CODE*2012 INTERNATIONAL ENERGY CONSERVATION CODE*2012 INTERNATIONAL FIRE CODE*2012 LIFE SAFETY CODE (NFPA 101)2009 ICC/ANSI-117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
* WITH ADOPTED AMENDMENTS
PROJECT DESCRIPTION:
THE PROJECT CONSISTS OF A 1 STORY TENANT BUILD-OUT IN AN EXISTING BUILDING.
THE BUILDING IS NOT SPRINKLERED.
ACCESSIBLE MEANS OF EGRESS:: IBC 1007.1ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITHIBC 1007.
OTHER LIFE SAFETY CONSIDERATIONS:
INTERIOR FINISH:: IBC 803.5
PANIC HARDWARE:: IBC 1008.1.9
PANIC AND FIRE EXIT HARDWARE SHALL COMPLY WITHIBC 1008.1.9.
OCCUPANCY TYPE:: IBC CHAPTER 3
LEVEL 1: BUSINESS
CONSTRUCTION TYPE:: IBC 602NOT SPRINKLERED
MIXED USE AND OCCUPANCY:: IBC 503 + 504 + 508 + 1004
EXITS AND EXIT ACCESS:: IBC 1014 + 1015 + 1016 + 1018MINIMUM NUMBER REQUIRED: 2 EXITSEXIT SEPARATION (1/2 OF DIAG.): 28'-7" MIN.COMMON PATH OF TRAVEL 75' MAXALLOWABLE TRAVEL DISTANCE TO EXIT: SEE 1016.1
EXIT CAPACITY:: IBC 1005MIN. DOOR WIDTH (IBC 1008.1.1): 32” CLEAR PER DOOR
EXIT DOORS
STAIRWAYS:: IBC 1009STAIRWAYS SHALL COMPLY WITH IBC 1009.
LEVEL 1(B) BUSINESS OCCUPANCY - 1340 SF
100 SF/OCCUPANT - 14
1 (36" NOMINAL = 33" ACTUAL) = 33"1 (72" NOMINAL = 68" ACTUAL) = 68"
= TOTAL"101"/ .15 PER OCC.
= 673 OCCUPANTS MAX
BUSINESSEXITS: CLASS ACORRIDORS: CLASS BROOMS AND ENCLOSED SPACES: CLASS C2012 EDITION OF INTERNATIONAL EXISTING BUILDING CODE*
FRONTAPPROACH
SID
EA
PP
RO
AC
H
Y = 3'-6" MIN. Y = 4'-0"MIN. IF DOOR HAS ACLOSER
Y = 3'-6" MIN. Y = 4'-0" MIN.IF DOOR HAS BOTH ALATCH AND A CLOSER
Y = 4'-0" MIN. Y = 4'-6"MIN. IF DOOR HAS BOTHA LATCH AND A CLOSER
X = 36" MIN. IF Y = 60" X =42" MIN. IF Y = 54"
30X48" CLEARFLOOR SPACE
ORIENTED FORFRONT APPROACH
ALL FAUCETSTO COMPLYWITH 4.19.5
MIRROR
CLEARFLOOR SPACE
CLEARFLOOR SPACE
36" GRABBAR MOUNTED6" FROM WALL
42" GRAB BARMOUNTED 6"FROM WALL
36" GRABBAR MOUNTED6" FROM WALL
42" GRAB BARMOUNTED 6"FROM WALL
1-1/2" O.D.GRAB BAR
TYPICAL
ROOM SIGN
INSULATE ALL EXPOSEDHOT WATER SUPPLY ANDDRAIN LINES WITH 'LAV-GUARD'OR EQUAL INSULATION
1. GRAB BARS SHALL BE 1¼” TO 1½” IN WIDTHOR OUTSIDE DIAMETER
THE CLEAR HAND SPACE MUST BE 1½” BETWEENTHE INNER FACE OF THE GRAB BAR AND THEFINISHED FACE OF THE WALL OR PARTITION
PROVIDE ADEQUATE BLOCKING IN WALL FORGRAB BARS TO BE ABLE TO SUPPORT A 250POUND LOAD APPLIED IN ANY DIRECTION ALONGITS LENGTH.
TOILETPAPERDISPENSER
18" GRABBAR
DOOR PULL CLEARANCESNTS
TYPICAL MOUNTING HEIGHTSNTS
CLEAR SPACE REQUIREDNTS
TOILET DETAILSNTS
TOP OF RIMTOP OF SEAT
FLUSH CTL. TOP OF BAR
SIGNDOOR HARDWARETHERMOSTAT FIRE PULLHAND DRYER ROOM & ACCESSIBLEFIRE
EXTINGUISHERMIRROR SOAP
DISPENSER
MOUNTEDSURFACE
DISPENSERPAPER TOWEL
ELEMENTARYTYPICALPAPER TOWEL
DISPENSERSURFACEMOUNTED
PUSH SIDEPUSH SIDE PULL SIDE
OUTLETS LAVATORY
PUSH SIDE
URINALWATER CLOSETTOILET PAPERDISPENSER
CLEARANCES FOR DOORS IN SERIES
PULL SIDE
TYP. GRAB BARDISPENSER
NAPKINTRASHRECEPTACLE
PAPER TOWELDISP. & TRASHRECEPTACLE
DISPENSERSEAT COVER
DISPENSERNAPKIN
DISPOSALCUP LIGHT
SWITCH
PULL SIDE
B. ACCESSIBLE LAVATORY
NOTE: FLUSH VALVE TOBE LOCATED ON WIDESIDE OF TOILET STALL.PROVIDE 9" TOECLEARANCE AT TOILETPARTITIONS
SCHOOL
HC
HC
EQ
EQ
19" MAX
MIN
15"
MIN
15"
CLEARANCE8" MIN KNEE
CLEARANCE6" MIN TOE
17" MIN
9" M
IN
27"
MIN
29"
MIN
34"
MA
X
40"
MA
X
18"
56"
MIN
5' - 1"
66"
MIN
5' - 3"
18"
17"-
19"
19"
7" MIN - 9" MAX
36"
40"
40"
12" MAX 42"
54"
36" 6"
17"-
19" 36
"
KN
EE
SP
AC
E
2' -
5"
TO
P O
F R
IM
2' -
10"
BO
T. O
F
3' -
4"
MA
X
TO
P O
F R
EF
LEC
TIV
E
6' -
2"
MIN
MIR
RO
R
SU
RF
AC
E
PO
INT
OF
OP
ER
AT
ION
TO
HIG
HE
ST
48"
MA
X
33"-
36"
44"
MA
X
MA
X
1' -
5"
1' -
7"
HC
17"-
19"
12"
36"
60"
48"
MA
X
48"
MA
X
36"
MA
X
48"
MA
X
48"
MA
X
48"
MA
X
3' -
4"
MA
X
28"
MA
X
1' -
3"
4' - 0"
4' - 0"
2'-0" MIN
Y
2'-0" MINX
YY
Y
4'-6" MIN 18".
5'-0
".4'
-0"
MIN
1'-0" W/ LATCH AND CLOSER
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A100
16030.ID
LIFE SAFETY PLAN ANDACCESSIBILITY
STANDARDS
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1
LIFE SAFETY PLAN
No. REVISED DATE
FEC
DW
CONFERENCE
104
OFFICE
105
OFFICE
106
OFFICE
107
ACCESSIBLERESTROOM
103
COPY/WORK
102
BISTRO
101
9' -
6"
OPEN OFFICE
100
CORRIDOR
108
A800
6
A800 5
A7001
10' - 0"10' - 0"10' - 0"
10' -
8"
INS
IDE
4' -
0"
CLR
.
INSIDE
1' - 8" CLR.
90.00°
A8001
6' - 8"
2' - 4"
7' -
1"
125.00°
1' - 3"
4' - 2"
2' -
0"
11' -
1"
B
B
B BB
B
B
B
B
12
125.00°
3
C
145.00°
3' - 6"
3' -
0"I.T.
102A
3' - 0"
4
TYPE A - METAL STUD PARTITION TO 6" ABOVE CEILING(ALL WALLS ARE TYPE A UNLESS OTHERWISE NOTED)
PLAN LEGENDGENERAL PLAN NOTES
TYPE B - METAL STUD PARTITION TO 6" ABOVE CEILING WITHSOUND INSULATION
B
TYPE C - METAL STUD PARTITION TO UNDERSIDE OF CEILING
D
1. ALL NEW WALLS SHOWN TO BE 3-5/8" METAL STUDS UNLESS NOTED OTHERWISE.2. WALLS ARE TYPE A UNLESS INDICATED OTHERWISE.3. ALL WALLS TO CONTINUE TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE.4. SOUND ATTENUATED PARTITIONS ARE INDICATED ON THIS SHEET PER THE LEGEND
ABOVE. REFER TO DETAILS SHOWN ON THIS SHEET FOR WALL TYPES INDICATED ONTHIS PLAN WITH A HATCH PATTERN OR DIAMOND.
5. FIRE RESISTIVE RATED PARTITIONS ARE THE BE CONTINUOUS AND INSTALLED INACCORDANCE WITH U.L. OR OTHER LSITED TESTING AGENCY CONSTRUCTIONDESIGN SPECIFICATIONS. RESISTANCE CONTINUITY TO BE MAINTAINED PER CODEREQUIREMENTS THROUGH INTERSTITIAL, FURRED AREAS, VOID SPACES,PENETRATIONS, AND MOUNTED EQUIPMENT BOXES.
6. PROVIDE DUST SHIELD AND CONSTURCTION BARRIERS DURING CONSTRUCTION.7. PROVIDE BLOCKING IN WALL FOR ALL WALL MOUNTED HANDRAILS, MILLWORK,
TOILET ACCESSORIES, GRAB BARS, OR OTHER WALL HUNG ITEMS.8. EXISTING FIRE RESISTANCE RATINGS TO BE MAINTAINED OR REPAIRED AT
PARTITIONS TO REMAIN, VERTICAL PENETRATIONS, AND HORIZONTAL SEPARATIONS.9. DOORS AND/OR WALLS WITHOUT TAGS ARE INTENDED TO BE EXISTING TO REMAIN.
REVIEW CONDITIONS AND REPORT DISCREPENCIES.10.ACOUSTIC CEILINGS AT OFFICES AND CONFERENCE ROOM TO BE COVERED WITH 3-
1/2" SOUND BATTING.
1 PROVIDE ACCESS PANEL TO BACKFLOW; VERIFY SIZE IN FIELD. PAINT TO MATCHADJACENT WALL.
NOTED PLAN KEY NOTES
FEC EXISTING FIRE EXTINGUISHER CABINET; ADJUST HEIGHTTO MEET ADA REQUIREMENTS
2 VERIFY REQUIRED CLEAR DIMENSIONS FOR BACKFLOW IN FIELD; REDUCE IF POSSIBLE.PROVIDE VERIFIED REQUIRED CLEAR DIMENSIONS TO ARCHITECT.
3 PARTIAL HEIGHT STUD WALL; SEE SHEET A800 FOR ADDITIONAL INFORMATION.
4 DRYWALL OPENING; PAINT ALL SIDES. USE ROUNDED CORNER BEAD AT ALLCORNERS TO PROVIDE BULLNOSE DRYWALL CORNER.
ROOF OR FLOOR DECK
BRACE AS REQUIRED FOR STABILITY
METAL STUDS AT 24" MAX O.C. (UNLESSNOTED OTHERWISE) FROM FLOOR SLABTO UNDERSIDE OF FLOOR SLAB ABOVEBRACE AS REQUIRED. GAUGE ASREQUIRED BY MANUFACTURER'S DESIGNSTANDARDS FOR ALLOWABLEDEFLECTION.
5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES
ANCHOR TO FLOOR DECK AS REQUIRED
SCHEDULED BASE
CONTINUOUS SEALANT AT HEAD AND SILL OFWALL
SCHEDULED FLOORING
SCHEDULED CEILING
STOP GYP BOARD 6" ABOVE CEILING
A 6" ABOVE CEILING1"=1'-0" 0 1 2
METAL STUD PARTITION TO
ROOF OR FLOOR DECK
BRACE AS REQUIRED FOR STABILITY
METAL STUDS AT 24" MAX O.C. (UNLESSNOTED OTHERWISE) FROM FLOOR SLABTO UNDERSIDE OF FLOOR SLAB ABOVEBRACE AS REQUIRED. GAUGE ASREQUIRED BY MANUFACTURER'S DESIGNSTANDARDS FOR ALLOWABLEDEFLECTION.
5/8" TYPE 'X' GYPSUM BOARD BOTH SIDES
ANCHOR TO FLOOR DECK AS REQUIRED
SCHEDULED BASE
CONTINUOUS SEALANT AT HEAD AND SILL OFWALL
SCHEDULED FLOORING
SCHEDULED CEILING
STOP GYP BOARD 6" ABOVE CEILING
FILL CAVITY WITH 3-1/2" ACOUSTIC BATTINSULATION.
WHERE WALL ON PLAN CALLS FOR ACOUSTICINSULATIONS BLANKETS LAY MINIMUM OF 36"HORIZONATALLY FROM WALL FACE
B 6" ABOVE CEILING1"=1'-0" 0 1 2
METAL STUD WITH SOUND INSULATION TO
SCHEDULED FLOORING
CONTINUOUS SEALANT AT HEADAND SILL OF WALL
C UNDERSIDE OF CEILING1"=1'-0" 0 1 2
METAL STUD PARTION TO
SCHEDULED BASE
ANCHOR TO FLOOR DECK AS REQUIRED5/8" TYPE "X" GYPSUM BOARD BOTH SIDES
SCHEDULED CEILING
STOP GYP BOARD AT CEILING - SEAL
METAL STUDS AT 24" MAX O.C.(UNLESS NOTEDOTHERWISE) FROM FLOOR SLAB TOUNDERSIDE OF CEILING. BRACE AS REQUIRED.GAUGE AS REQUIRED BY MANUFACTURERSDESIGN STANDARDS FOR ALLOWABLEDEFLECTION.
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A200
16030.ID
NOTED FLOOR PLANAND PARTITION TYPES
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1 NOTED AND DIMENSIONED PLAN
No. REVISED DATE
FEC
DW
CONFERENCE
104
OFFICE
105
OFFICE
106
OFFICE
107
ACCESSIBLERESTROOM
103COPY/WORK
102
BISTRO
101
OPEN OFFICE
100
CORRIDOR
108
103
104105 106 107
102A
I.T.
102A
DOOR GENERAL NOTES
4.
6.
1.
2.
3.
5.
7.
8.
9.
10.
11.
12.
ALL DOOR GLAZING TO BE TEMPERED GLASS TO COMPLYWITH IBC 2406.3.
HEIGHTS AND WIDTHS INDICATED ON SCHEDULE ARE DOOR ANDWINDOW SIZES. FRAME ROUGH OPENINGS TO ACCOMODATEWINDOW/DOOR SIZE, PLUS ANY ASSOCIATED FRAME, SHIM, ANDSEALANT SPACE AS RECOMMENDED BY THE SELECTEDMANUFACTURER.
SUBMIT FINAL DOOR AND WINDOW SCHEDULE FOR APPROVALBY ARCHITECT PRIOR TO PLACING ORDER OR ROUGH FRAMINGOF OPENINGS.
KEY ALL CYLINDERS TO OWNER'S REQUIREMENTS AND PROVIDETWO KEYS PER LOCKSET AND SIX MASTER KEYS. SUBMITPROPOSED KEYING SCHEDULE AFTER CONSULTATION WITH OWNERFOR OWNER'S APPROVAL.
ALL OPERATING HARDWARE MUST BE LEVER OPERATED TOMEET ADA ACCESSIBILITY GUIDELINES.
ALL LATCHING AND LOCKING DOORS SHALL BE OPERABLE WITHA SINGLE EFFORT BY LEVER TYPE DOOR HARDWARE.
HAND ACTIVATED HARDWARE SHALL BE CENTERED BETWEEN30" AND 44" ABOVE THE FLOOR.
COMPLY WITH ALL APPLICABLE CODES FOR GRADE ANDINSTALLATION OF DOOR HARDWARE AND ACCESSORIES;INCLUDING THE AMERICAN'S WITH DISABILITIES ACT.
IN NO CASE SHALL THE FLOOR OR LANDING BE MORE THAN 1/2"LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE INLEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED AT 1:2 MAXIMUMSLOPE.
EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 1/2" LBS. FOREXTERIOR DOORS, 5 LBS. FOR INTERIOR DOORS, AND 15 LBS.FOR FIRE DOORS.
THE BOTTOM 10" OF ALL HAND-ACTIVATED DOORS SHALL HAVEA SMOOTH UNINTERRUPTED SURFACE.
DOORS WITH HEIGHTS 91" - 120" TO HAVE 4 HINGES.
DOOR STOPS AND HOLDERS:
2.2.1.2.2.
4.4.1.4.2.4.3.
1.
3.
ACCEPTABLE MANUFACTURERS:ROCKWOOD MANUFACTURING (RO)TRIMCO (TC)
ACCEPTABLE MANUFACTURERS:RIXSON DOOR CONTROLS (RF)ROCKWOOD MANUFACTURING (RO)SARGENT MANUFACTURING (SA)
DOOR CLOSERS, SURFACE MOUNTED (COMMERCIAL DUTY): DOORSTOPS AND BUMPERS: ANSI/BHMA A156.16, GRADE 1 CERTIFIED DOORSTOPS AND WALL BUMPERS. DO NOT MOUNT FLOOR STOPS WHERETHEY WILL IMPEDE TRAFFIC. WHERE FLOOR OR WALL BUMPERS ARENOT APPROPRIATE, PROVIDE OVERHEAD TYPE STOPS AND HOLDERS.
OVERHEAD DOOR STOPS AND HOLDERS: ANSI/BHMA A156.6, GRADE 1CERTIFIED OVERHEAD STOPS AND HOLDERS TO BE SURFACE ORCONCEALED TYPES AS INDICATED IN HARDWARE SETS. PROVIDENON-HANDED DESIGN WITH MOUNTING BRACKETS AS REQUIRED FORPROPER OPERATION AND FUNCTION.
13. 14. ACCEPTABLE DOOR MANUFACTURERS:VT ARCHITECTURAL WOOD DOORSPLAIN SLICE CHERRY VENEERCOLOR: TBD
GRAHAMPLAIN SLICE CHERRY VENEERCOLOR: TBD
15. DOOR HARDWARE TO BE: SARGENT DL SERIES, "F" LEVER.
VARIES - SEE SCHEDULE
8' -
0"
WOOD DOOR, STAINED
3' - 0"
8' -
0"
WOOD DOOR, STAINED
FULL VIEW GLASS
2" VARIES 2"
8' -
0"
2"
2" CLEAR ANODIZEDALUMINUM FRAME
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A220
16030.ID
CODED DOOR PLANAND SCHEDULE
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1 CODED DOOR PLAN
DOOR SCHEDULE
NUMBERDOOR FRAME HARDWARE
REMARKSROOM NAME WIDTH HEIGHT THICK TYPE MATERIAL FINISH GLAZ TYPE MATERIAL FINISH SET
102A I.T. 2' - 6" 8' - 0" 1 3/4" B SCWD STAIN - F1 ANODIZED ALUM. CLEAR LOCKSET103 ACCESSIBLE RESTROOM 3' - 0" 8' - 0" 1 3/4" B SCWD STAIN - F1 ANODIZED ALUM. CLEAR PRIVACY PROVIDE CLOSER104 CONFERENCE 3' - 0" 8' - 0" 1 3/4" A SCWD STAIN FVG F1 ANODIZED ALUM. CLEAR PASSAGE105 OFFICE 3' - 0" 8' - 0" 1 3/4" A SCWD STAIN FVG F1 ANODIZED ALUM. CLEAR PASSAGE106 OFFICE 3' - 0" 8' - 0" 1 3/4" A SCWD STAIN FVG F1 ANODIZED ALUM. CLEAR PASSAGE107 OFFICE 3' - 0" 8' - 0" 1 3/4" A SCWD STAIN FVG F1 ANODIZED ALUM. CLEAR PASSAGE
1/2" = 1'-0"B DOOR TYPE B
1/2" = 1'-0"A DOOR TYPE A
1/2" = 1'-0"F1 FRAME TYPE F1
No. REVISED DATE
ACCESSIBLERESTROOM
103
COPY/WORK
102
BISTRO
101
OFFICE
105
OFFICE
106
OFFICE
107
CONFERENCE
104
OPEN OFFICE
100
10' - 2"
9' - 0"
9' - 4"
C C
C C C CC
C
C
C
A A A A A A
W
P
C
C
P2
P2
P2
P2
P2
C
4' - 10" 8' - 0" 8' - 0" 8' - 0"
9' -
0"
3' - 6"2' -
10"
3' - 10"
4' -
0"
4' -
0"
3' - 8"
1' -
4"
1' -
4"
A6003
7' - 10"
C2
C2
C2
R 34' - 11 1/2"
14' - 2"
15' -
1"
5
A600
A
C
I.T.
102A
A6002
E.C.
E.C.
1. CEILING DETAILS ARE GIVEN TO ILLUSTRATE DESIGN INTENT. GENERALCONTRACTOR SHALL PROPOSE ALTERNATE CONSTRUCTION DETAILINGWHEN APPROPRIATE UPON ARCHITECTS' APPROVAL.
2. WHERE APPLICABLE, SEE INTERIOR AND EXTERIOR WALL SECTIONS FORADDITIONAL CEILING DETAILS NOT SHOWN ON THIS DRAWING SHEET.
3. WHERE EXPOSED CEILING AREAS EXIST, CLEAN AND PREPARE ALL SURFACES FORPAINTING. REMOVE TRASH, DUST AND DEBRIS AS REQUIRED. ALL ABANDONEDSYSTEMS SHALL BE REMOVED.
4. ALL EXPOSED DUCTWORK AND CONDUIT TO BE PAINTED TO MATCH CEILING.
5. HVAC DIFFUSERS ILLUSTRATED FOR DESIRED AESTHETIC IMPACT ONLY.CONTRACTOR TO COORDINATE FUNCTIONAL REQUIREMENT DESIGN / BUILDSUBCONTRACTOR.
6. HANGER WIRES ARE REQUIRED AT ALL FOUR CORNERS OF ALL LIGHT FIXTURES,REGISTERS, GRILLS AND ANY ARCHITECTURAL FEATURES UNLESS OTHER MEANS OFSUPPORT IS PROVIDED.
7. ALL CONDUIT ON EXPOSED CONCRETE CEILINGS TO BE HARD CONDUIT GROUPEDAND RUN IN 90 DEGREE ANGLES TO PREDOMINANT STRUCTURE OF BUILDING.
8. ALL MULTIPLE SWITCH LOCATIONS ARE TO BE GANGED AND INSTALLED WITH ASINGLE FACE PLATE. COVER PLATES SHALL NOT MODIFIED.
9. ALL CEILING ANGLES SHALL BE TIGHT TO PARTITION, FREE FROM DEFECTS, BREAKSAND OTHER IRREGULARITIES. WHERE PAINT IS REQUIRED FOR THE PARTITIONFINISH, ANGLES SHALL BE CAULKED TO WALL PRIOR TO PAINT FINISH.
10. WHERE CLEAN TILE EXISTS, INSTALL HOLD DOWN CLIPS AS NECESSARY PERCODE REQUIREMENTS.
11. SPEAKERS, SMOKE DETECTORS, SENSORS AND SPRINKLER HEADS ARE TO BECENTERED WITHIN CEILING TILES, UNLESS OTHERWISE NOTED.
12. WHERE SPRINKLER HEADS OCCUR WITHIN DRYWALL BULKHEADS OR CEILINGS,HEADS SHALL BE CONCEALED.
GENERAL CEILING NOTES
C6" LED DOWNLIGHTCOOPER LIGHTINGPORTFOLIO LEDLD6A20D010TE-ERM6A20835-6LMOH
NEW GYPSUM BOARD CEILING SYSTEM
NEW 2x2 SUSPENDED ACOUSTIC CEILING SYSTEM
CEILING HEIGHT (FROM FINISH FLOOR)NOTE: CEILING IS 9'-0" A.F.F., UNLESS OTHERWISE NOTED ON PLAN
CEILING LEGEND
0' - 0"
NEW GYPSUM BOARD CEILING SYSTEM
A
P
DECORATIVE PENDANTTECH LIGHTINGMULBERRY PENDANT700-TD-MULP-C-S-CFHEIGHT: TBD
P2DECORATIVE PENDANTEUREAK LIGHTINGSILENE CLASSIC PENDANTHEIGHT: 6'-6" AFF TO BOTTOM OF PENDANT
W
WALL SCONCEEUREKA LIGHTINGSILENE CLASSIC DOUBLE SCONCE3155B-JDJ-2XCF-D-18-RC-SC-FROHEIGHT: 7'-10" O.C.
C24' RECESSED LINEAR LED LIGHTAXIS LIGHTINGBBRLED-B3-MF-750-35-FL-4'-W-UNV-D-1-TB15
E.C. EXPOSED CEILING - EC1
18' - 0"
1' - 0"
1' - 0"
16' - 0"
27.00°
9' - 10"
1' - 0"
7' - 10"
1' - 0"
2' - 10"
4' -
0"
OPEN OFFICE
100
E.C.
E.C.
8' -
4"
5"7"
10"
10' -
2"
2' - 1"
1' - 0 1/2"
CURVED; SEE 1/A600 FORRADIAL DIMENSIONS
9' -
4"
TO
P O
F W
IND
OW
10' -
8"
BO
TT
OM
OF
WO
OD
JO
IST
12' -
1"
UN
DE
RS
IDE
OF
DE
CK4
A600
2' - 1"
2' - 4"
1' - 0 1/2"
SEE 1/A600 FOR RADIALDIMENSION
SEE 4/A600 AND SHEETA800 FOR SOFFIT HEIGHTS
BISTRO
101
8' - 4"
9' - 4"
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A600
16030.ID
REFLECTED CEILINGPLAN
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1 REFLECTED CEILING PLAN
1/2" = 1'-0"3 ENLARGED CEILING PLAN AT OPEN OFFICE 100
1/2" = 1'-0"4 SECTION AT SOFFITS
1/2" = 1'-0"5 EXISTING STRUCTURE
1/2" = 1'-0"2 ENLARGED CEILING PLAN AT BISTRO 101
No. REVISED DATE
A7002 3
ACCESSIBLERESTROOM
103
A
C
BDE
F
G
3"
H
I
6"
1' - 10"
2' -
10"
4' - 0"
A.F
.F.
7' -
10"
O.C
.
EQ EQ
EP1QT1 COUNTER,APRON AND BACKAND SIDE SPLASH
RB2
2" RADIUS ATCORNER
6"
INSULATE ALL PIPES PER ADAREQUIREMENTS; COLOR:WHITE
5' -
0"
6"
7' - 1"
USE WT2 BULLNOSE TILE ATTOP EDGE (DALTILE ELEVARE#S-4D49, MATTE LUNAR)
EP1
EP1
WT2 TO 5'-6" AFF
RB2
SINK: KOHLERLADENA K-2214WHITE
FAUCET AND HAND DRYER: DYSONAIRBLADE TAPAB09 SHORT
NOTE: PROVIDE POINT OF USE WATER HEATER AT FAUCET
WATER CLOSET: AUTO-FLUSH WITH MANUAL BACKUP
URINAL: AUTO-FLUSH WITH MANUAL BACKUP
RESTROOM FIXTURES
A
B
C
D
E
F
TOILET ACCESSORY LEGENDITEM DESCRIPTION MANUFACTURER MODEL # REMARKS
42" GRAB BAR BOBRICK B-680642 -
36" GRAB BAR BOBRICK B-680836 -
18" VERTICAL GRAB BAR BOBRICK B-680618 -
TOILET TISSUE DISPENSER BOBRICK B-541 PROVIDE (2) IN RESTROOM
DELTA 72065T
FULL LENGTH MIRROR - - 2'-0" W X 6'-0" H MIRROR, BRUSHED NICKEL TRIM, MOUNT AT 8" A.F.F.
AUTOMATED SOAP DISPENSER -
G FRAMED MIRROR AMBIANCE 2" WOOD FRAME, STAINED30" X 48" MIRROR WITH 2" WOOD FRAME STAINED TO MATCH SAMPLE PROVIDED
BY SOUTHEAST VENTURE; CONTACT GINNY WILSON (615) 353-0723
B
C
SANITARY NAPKIN DISPOSAL BOBRICK B-270 -
RECESSED WASTE RECEPTACLE BOBRICK B-B-3644 -
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A700
16030.ID
ENLARGED TOILETPLAN AND ELEVATIONS
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/2" = 1'-0"1 ENLARGED ACCESSIBLE RESTROOM 103 PLAN
1/2" = 1'-0"2 RESTROOM 103 SINK WALL
1/2" = 1'-0"3 RESTROOM 103 WET WALL
No. REVISED DATE
DW
A8002
3
BISTRO
101
CORRIDOR
108A800
4
GROMMET; COLOR: ALMOND
8" DIA. TRASH CUTOUT;FINISH SIDE OF CUTOUTWITH QT1
10"
7"5"
5' -
6"
2' -
10"D.W. U.C.
REF.
3' - 6"3/4"3 EQUAL SECTIONS 2' - 3"
PAINT ALL SIDES OF SOFFIT GYP1
PAINT WALL BEHIND PT1
PAINT ALL SIDES OF SOFFIT PT3
RB1
PT1
24" DEEP BASE CABINETSWITH DRAWERS ORADJUSTABLE SHELVESAND PL TOEKICK; PL1
10 1
/2"
6"6"
6"
WT1 BACKSPLASH
1' - 3" EQ. EQ. EQ. EQ. 1' - 3"
QT1
REJUVENATION SHELVING:(6) LARGE STRAP SHELF BRACKETS,POLISHED NICKEL, #C1074(3) 10" X 3' SALVAGED PONDEROSAPINE SHELVES, #C0254
8' -
4"
2' -
0"
2' -
10"
6" 6"
6' -
6"
PT1
3/4" END PANEL, PL1
2' -
10"
7
A800
1' - 3"2' - 0"1' - 3"
24" DEEP BASE CABINETSWITH ADJUSTABLESHELVES, MICROWAVECUBBY AND DRAWER ANDPL1 TOEKICK; PL1
INTEGRATED TOEKICK AT TRASHCABINET; FINISH ALL SIDES OFTRASH CUTOUT (8" DIA.) WITH QT1
TRASH
CIRCULAR CUTOUT FOR TRASH
PAINTED WALL BEYOND, PT1
QT1
RB1; TURN BACK TO END ATCABINET
PROVIDE GROMMET ATCOUNTER; GROMMETCOVER TO BE ALMOND
3' -
0"
2' -
0"
2' -
10"
1' -
2"
9' -
0"
(3 EQ. SECTIONS)
4' - 0"
SOFFIT, PT1
12" DEEP UPPERCABINETS WITHADJUSTABLESHELVES; PL2
24" DEEP BASECABINETS WITHADJUSTABLESHELVES ORDRAWERS ANDPLASTIC LAMINATETOEKICK; PL2
PL2 COUNTERAND 4" BACK ANDSIDE SPLASH
7
A800
Sim
PT1
RB1
QT1
SINK: ELKAY"GOURMET" UNDERMOUNT SINGLE BOWL SINKEELUHAD211555STAINLESS STEEL
FAUCET: GROHEELBERON DUAL SPRAY PULL DOWNMODEL: 30211DC0FINISH: SUPERSTEEL
NOTE: PROVIDE POINT OF USE WATER HEATER AT FAUCET
BISTRO FIXTURES
1. CASEWORK HARDWARE TO BE HAFELE 109.74.602; FINISH: BRUSHEDNICKEL.2. SEE FINISH PLAN AND ELEVATIONS FOR ALL CASEWORK FINISHES. IFCONFLICT EXISTS OR MULTIPLE FINISHES ARE CALLED FOR CONSULTARCHITECT.3. ALL EXPOSED AND SEMI-EXPOSED SURFACES TO BE PLASTICLAMINATE. SEE FINISH SCHEDULE.4. ALL WOOD SUBSTRATES SUPPORTING SOLID SURFACING PRODUCTSTO BE PAINTED WHITE PRIOR TO INSTALLATION5. ALL CASEWORK TO BE SEALED AGAINST ADJACENT WALL. PROVIDECLEAR CAULKING AT BACKSPLASHES & CASEWORK.6. ALL INTERIOR SURFACES OF PLASTIC LAMINATE CABINETS ARE TOBE WHITE MELAMINE.
GENERAL CASEWORK NOTES
5' - 0" 1' - 0" 5' - 0" 1' - 0" 1' - 0" 5' - 0" EQ. 5' - 0" EQ.
10' -
2"
9' -
4"
TYPICAL:2" CLEAR ANODIZED ALUMINUMCHANNEL AT TOP; 4" CLEARANODIZED ALUMINUM CHANNELAT BOTTOM
RB1
PT2
PT2
2' - 0"
2' -
10"
PARTIAL HEIGHT STUD WALLFOR POWER; PROVIDEGROMMET FOR POWERACCESS AT COUNTERTOP
ADJUSTABLE SHELVES
PLASTIC LAMINATE TOEKICK
QUARTZ COUNTERTOP
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A800
16030.ID
ENLARGED PLANS ANDELEVATIONS
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/2" = 1'-0"1
ENLARGED BISTRO 101 PLAN 1/2" = 1'-0"
2BISTRO 101
1/2" = 1'-0"3
BISTRO 101 PENINSULA
1/2" = 1'-0"5 COPY/WORK 102
1/2" = 1'-0"4
BISTRO 101 PENINSULA (CORRIDOR SIDE)
1/2" = 1'-0"6 CONFERENCE AND OFFICE GLAZING
1/2" = 1'-0"7 SECTION AT CASEWORK AND PARTIAL HEIGHT WALL
No. REVISED DATE
FEC
DW
U.C.REF.
CONFERENCE
104
OFFICE
105
OFFICE
106
OFFICE
107
ACCESSIBLERESTROOM
103
BISTRO
101
OPEN OFFICE
100
CORRIDOR
108
COPY/WORK
102
M.W.
J4
4
2
1
3
36"AFF
I.T.
102A
15' - 6"
7' -
6"
3' - 6"
5' -
6"
1
DED
4
4
1. ALL OUTLETS 1'-6" FROM FINISH FLOOR TO CENTERLINE OF OUTLET UNLESSOTHERWISE NOTED.
2.
3.
THIS POWER PLAN REPRESENTS THE DESIGN INTENT FOR LOCATING OUTLETS TOSUIT THE USER'S GENERAL REQUIREMENTS. IT IS THE RESPONSIBILITY OF THEELECTRICAL ENGINEER OF RECORD TO MEET ALL CODES AND SUBMIT FINAL DESIGN.
ALL ELECTRICAL, VOICE DATA, AND SWITCH PLATES TO BE ALMOND.
REDUCE ELECTRICAL PANEL TO SMALLER SIZE APPROPRIATE FOR SIZE ANDREQUIREMENTS OF TENANT'S SPACE.
DUPLEX RECEPTACLE
QUAD-PLEX RECEPTACLE
DUPLEX RECEPTACLE @ 44" A.F.F. UNLESS NOTED
QUAD-PLEX RECEPTACLE @ 44" A.F.F. UNLESS NOTED
DEDICATED RECEPTACLE
DATA OUTLET
DATA OUTLET @ 44" A.F.F. OR HEIGHT NOTED
POWER JUNCTION BOX FOR WORKSTATIONS;NUMBER INDICATES NUMBER OF WORKSTATIONS SUPPORTED.
WALL OUTLETS
FLOOR-MOUNTED FLUSH COMBINATION DATA / ELECTRICAL (BLACK)
FLOOR OUTLETS
GENERAL POWER NOTES
POWER PLAN KEY NOTES
POWER PLAN LEGEND
J
COMMUNICATIONS JUNCTION BOX FOR WORKSTATIONS;NUMBER INDICATES NUMBER OF WORKSTATIONS SUPPORTED.
FLOOR-MOUNTED FLUSH COMBINATION QUAD DATA / ELECTRICAL (BLACK)
2 PROVIDE POWER AS REQUIRED BY APPLIANCE SPECIFICATIONS.
3 PROVIDE DATA AND FAX LINE FOR COPY MACHINE.
4. AS PER THE DESIGN-BUILD INTENT OF THIS PROJECT, CONTRACTOR SHALL INSTALLTHE MINIMUM AMOUNT OF RECEPTACLES REQUIRED AND ALL ADDITIONALELECTRICAL REQUIREMENTS TO MEET CURRENT ELECTRIC CODES.
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
A900
16030.ID
POWER AND DATALOCATION PLAN
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1
POWER/DATA LOCATION PLAN
No. REVISED DATE
MAT1MAT2
.
BASE
FIN
EXTENT OFFINISH &ACCENT FINISH
CEILING TYPEWALL FINISHBASE FINISHFLOOR FINISH
TRANSITION OFMATERIALS
SYMBOL DESCRIPTION SPECIFICATION
ACOUSTICAL CEILING
MFG:STYLE:SIZE:COLOR:
ARMSTRONGDUNE TEGULAR24" X 24"WHITE
CEILING GRIDMFG:STYLE:COLOR:
ARMSTRONGPRELUDE 15/16"WHITE
EXPOSED CEILING DRYFALL PAINT - BLACK
GYPBOARD CEILINGPAINTED
MFG:COLOR:FINISH:
BENJAMIN MOOREWINDS BREATH 981LATEX EGG SHELL
SYMBOL DESCRIPTION SPECIFICATION
EPOXY PAINT
WALLCOVERING
MFG:
REF. #:PATTERN:COLOR:
TBD - PROVIDE ALLOWANCE OF $25/LY,MATERIALSTBDTBDTBD
MFG:COLOR:FINISH:
BENJAMIN MOOREWINDS BREATH 981LOW GLOSS WATER
PAINT
1 PRIMER COAT2 FINISH COATS
MFG:COLOR:FINISH:
BENJAMIN MOOREWINDS BREATH 981LATEX EGG SHELL
WALL TILE
MFG:PATTERN:COLOR:SIZE:GROUT:
GIO TILECRYSTAL GLASSBONE2" X 6" BRICK MOSAICTEC; STANDARD WHITE 931
SYMBOL DESCRIPTION SPECIFICATION
RUBBER BASE
MFG:STYLE:COLOR:HEIGHT:
MANNINGTONCONTINUOUS ROLL COVE BASESABLE 9114"
SYMBOL DESCRIPTION SPECIFICATION
CARPET
MFG:STYLE:PATTERN:COLOR:INSTALLATION:
SHAW CONTRACTCARPET TILEFOLDED EDGE TILE 5T062WHITE BURLAP 60706ASHLAR
CARPET
MFG:STYLE:PATTERN:COLOR:INSTALLATION:
RESILIENT FLOORING
MFG:STYLE:PATTERN:COLOR:
MANNINGTONLVT 12" X 18"SPACIASS5A3610 - PLATINUM
SYMBOL DESCRIPTION SPECIFICATION
PLASTIC LAMINATE
MFG:PATTERN:COLOR:FINISH:
TBD - PREMIUM GRADE PLASTIC LAMINATETBDTBDTBD
QUARTZ
MFG:COLOR:THICKNESS:EDGE PROFILE:FINISH:
CAMBRIAKIRKSTEAD3 CMEASEDPOLISHED
PT1
AC1
EC
GYP1
EP1
PT1
WC1
WT1
PL1
QT1
RB1
CP1
CP2
RF1
WALL FINISHBASE TYPE
CARPET: PROVIDE (1) BOX OF EACH CARPET TILES: CP1, CP2
SEE FINISH PLANS, ELEVATIONS, DETAILS AND REFLECTED CEILING PLAN FORCLARIFICATION OF EXTENT OF FINISH MATERIALS.
NO SUBSTITUTIONS OF SPECIFIED FINISHES WILL BE ALLOWED WITHOUT PRIORAPPROVAL FROM THE INTERIOR DESIGNER.
THE DRAWINGS ATTACHED MAY NOT REFLECT ACTUAL FIELD CONDITIONS. IN NO CASESHALL DIMENSIONS BE SCALED FROM DRAWINGS. THE CONTRACTOR SHALL VERIFY ALLCONDITIONS AND THE INTERIOR DESIGNER SHALL BE NOTIFIED OF ANY DISCREPANCIES ORCONFLICTS WITH DIMENSIONS OR CONDITIONS IN THE FIELD BEFORE PROCEEDING WITHSUBSEQUENT WORK.
THE GENERAL CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE DOCUMENTSAND FINISH PLANS AND SHALL AT ONCE REPORT TO THE INTERIOR DESIGNER ANY ERROR,INCONSISTENCY OR OMISSION DISCOVERED.
ALL SUBCONTRACTORS SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITHEXISTING CONDITIONS BEFORE SUBMITTING BIDS AND/OR PROCEEDING WITH ANY WORK.SUBMISSION OF BID INDICATES THAT THE CONTRACTOR HAS VERIFIED EXISTINGCONDITIONS.
ALL SUBCONTRACTORS SHALL TAKE OUT ALL NECESSARY INSURANCES TO INDEMNIFYAND HOLD HARMLESS THE OWNER, ARCHITECT AND AGENTS THEREOF FROM ANY DAMAGESRESULTING FROM CONTRACTORS' EXECUTION OF WORK.
ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OFTHE BUILDING CODE, OSHA, ALL OTHER APPLICABLE CODES AND ALL OTHER GOVERNINGAUTHORITIES HAVING JURISDICTION.
SUBCONTRACTORS SHALL PROVIDE SUBMITTALS TO THE INTERIOR DESIGNER VIAGENERAL CONTRACTOR FOR APPROVAL PRIOR TO FABRICATING OR PURCHASING MATERIALS.ALL SUBMITTALS SHALL BE CLEARLY MARKED WITH MANUFACTURER, STYLE, COLOR ANDFINISH MATERIAL LEGEND CODE. ALL PAINT SUBMITTALS MUST INDICATE PAINT COLORFORMULA AS WELL AS STORE LOCATION WHERE PAINT IS TO BE PURCHASED.
ALL PARTIES RESPONSIBLE FOR DELIVERING FINISHES TO THE SITE SHALL CHECKQUANTITIES AND DELIVERY DATES AS SOON AS BID IS AWARDED. CONTRACTOR SHALL BERESPONSIBLE FOR MEETING ALL DELIVERY LEAD TIMES FOR FINISH MATERIALS ANDFABRICATION WITHIN THE CONSTRUCTION SCHEDULE. ALL DELIVERY TIMES MUST BECONFIRMED, AND ANY EXCESSIVE LEAD TIME MUST BE BROUGHT TO THE INTERIORDESIGNER'S ATTENTION IMMEDIATELY.
ALL FINISH MATERIALS SHALL BE INSTALLED PER MANUFACTURER'SRECOMMENDED SPECIFICATIONS, INSTRUCTIONS AND REQUIREMENTS.
GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLETING AND ACTIVATING ALLFINISH WARRANTIES. ALL WORK SHALL BE GUARANTEED AGAINST DEFECT FOR ONE YEAR.
GENERAL CONTRACTOR TO PROVIDE INSTALLATION AND MAINTENANCE MANUALS FORALL FINISH MATERIALS TO THE OWNER.
ALL RUBBISH AND DEBRIS RESULTING FROM DEMOLITION AND/OR NEW WORK SHALL BEDISPOSED OF OFFSITE AND SHALL NOT BE ALLOWED TO ACCUMULATE. ALL AREAS INFACILITY ARE TO BE KEPT FREE AND CLEAR OF MISCELLANEOUS CONSTRUCTIONEQUIPMENT, MATERIALS, DEBRIS, ETC. WORK AREAS SHALL BE CLEANED AND PICKED UPDAILY. AFTER INSTALLATION OF FLOORING, NO FOOD OR BEVERAGE ALLOWED IN FINISHEDAREAS.
THE CONTRACTOR SHALL, UPON COMPLETION, REMOVE ALL SPLATTERED PAINT,ADHESIVE OR OTHER DEBRIS FROM FINISHED SURFACES, LIGHT FIXTURES, DIFFUSERS,REGISTERS, CASEWORK, DOORS, WINDOWS, TRIM,ETC.
FINAL CLEANUP: THE CONTRACTOR SHALL MAKE CERTAIN THAT ALL HOUSEKEEPINGCLEANUP ITEMS ARE DONE PRIOR TO MOVE-IN. THIS WOULD INCLUDE WIPING DOWN, CLEANINGGLASS, LIGHT LENS AND AIR DIFFUSERS; WASHING, WAXING, VACUUMING, AND ANY OTHERSERVICES WHICH WOULD BE PERFORMED UNDER THE CONTRACTOR'S MAINTENANCE CLEANINGPROGRAMS. UPON COMPLETION OF WORK, ALL WASTE MATERIAL, RUBBISH, TOOLS,CONSTRUCTION EQUIPMENT, AND OTHER SURPLUS MATERIALS SHALL BE REMOVED FROM THESITE.
ALL FURNISHINGS ARE TO BE OWNER FURNISHED, OWNER INSTALLED.
SUBCONTRACTOR IS TO PROVIDE "SURPLUS" STOCK AS NOTED BELOW. SURPLUSSTOCK SHALL BE PROVIDED ON EACH DIFFERENT MANUFACTURER, STYLE, COLOR ANDFINISH SPECIFIED: REFER TO SPECIFICATIONS SECTION (IF APPLICABLE) FOR ADDITIONALINFORMATION. FINAL PAYMENT SHALL NOT BE MADE UNTIL STOCK IS DELIVERED.
NO PAINTING OR INTERIOR FINISHING SHALL BE DONE UNDER CONDITIONS WHICHWILL JEOPARDIZE THE QUALITY OR APPEARANCE OF SUCH WORK. ALLWORKMANSHIP WHICH IS JUDGED LESS THAN FIRST QUALITY BY THE INTERIORDESIGNER WILL BEREJECTED.
ALL SURFACES SHALL BE PREPARED TO RECEIVE THE SPECIFIED FINISH. ALL GYPSUMBOARD SURFACES SHALL BE TAPED AND SANDED SMOOTH AND PREPARED TO RECEIVE THESPECIFIED FINISH. PAINT GRADE WOODWORK SHALL BE HAND SANDED BETWEEN COATS ANDDUSTED CLEAN. ALL HOLES, PITCH POCKETS OR SAPPY PORTIONS SHALL BE SCRAPED ANDSEALED. NAIL HOLES, CRACKS OR DEFECTS SHALL BE PUTTIED AFTER FIRST COAT, WITH PUTTYMATCHING COLOR OF STAIN OR PAINT FINISH. REMOVE OIL OR GREASE WITH MINERAL SPIRITS.
ALL CRACKS, HOLES, IMPERFECTIONS IN EXISTING WALLS, PARTITIONS OR GYP. BD. SHALLBE FILLED WITH PATCHING PLASTER AND SMOOTHED TO MATCH ADJOINING SURFACES.
INTERIOR GYPSUM BOARD SURFACES SHALL BE WIPED WITH A DAMP CLOTH JUST PRIORTO APPLICATION OF THE FIRST COAT, IN ORDER TO LAY FLAT ANY NAP WHICH MAY HAVEFORMED IN SANDING PROCESS.
FINISH DRYWALL TO FLOOR WHERE SEALED CONCRETE IS THE FLOORING.
PAINTING CONTRACTOR TO VERIFY ALL FINISHES FOR PROPER PRIMER APPLICATIONS.
PROVIDE INTERIOR DESIGNER WITH A MINIMUM OF (3) 8" x 10" BRUSH-OUTS OF EACHCOLOR AND FINISH FOR APPROVAL AT LEAST 2 WEEKS PRIOR TO SITE APPLICATION. ONE 3' x3' ON-SITE APPLICATION OF EACH WALL COLOR WILL BE REQUIRED ONE WEEK PRIOR TOFINAL APPROVAL. INTERIOR DESIGNER RESERVES THE RIGHT TO ADJUST ANY COLOR ORFINISH ONCE THE WALL TEST HAS BEEN MADE.
MISCELLANEOUS METAL (RETURN AND AIR SUPPLY GRILLES, EXPANSION JOINTS,ETC.) LOCATED ON WALL SURFACES TO BE PAINTED TO MATCH ADJACENT WALLCOLOR.
** DO NOT PAINT FACTORY PREFINISHED FRAMES.
WHEN WALLCOVERING IS SPECIFIED, WRAP WALLCOVERING ACROSS THE FRONT,UNDERSIDE AND BACKSIDE OF SOFFITS, UNLESS OTHERWISE NOTED. IF DISCREPANCIES ARISE,CONTACT THE INTERIOR DESIGNER.
CAULK ALL DOOR FRAMES AFTER PAINTING AND WALLCOVERING INSTALLATION IS COMPLETE.COLOR OF CAULK TO BE CLEAR FINISH, UNLESS OTHERWISE NOTED.
REFER TO INTERIOR ELEVATIONS FOR FURTHER CLARIFICATIONS OF WALL FINISHES.
CONTRACTOR IS RESPONSIBLE FOR NEW FLOOR PREPARATION, INITIAL CLEANING ANDSEALING OR WAXING (IF REQUIRED). REFER TO MANUFACTURER'S GUIDELINES FORCORRECT PROCEDURES AND PRODUCTS.
ALL RUBBER BASE IS TO BE CONTINUOUS ROLLS. DO NOT USE 4'-0" SECTIONS. MITERINSIDE CORNERS. WRAP OUTSIDE CORNERS (NO SEAM AT OUTSIDE CORNERS.)
MODIFY EXISTING FLOOR SURFACES AS REQUIRED TO INSTALL NEW FLOORINGMATERIALS, THUS PREVENTING NOTICEABLE LUMPS OR DEPRESSIONS. CONCRETE SLABS TOBE CURED AND DRY TO BOND WITH ADHESIVE. CONCRETE SLABS TO HAVE pH RANGERECOMMENDED BY MANUFACTURER OF FLOORING MATERIAL.
WHERE NEW FLOOR COVERING AND/OR BASE IS SPECIFIED, THE SAME FLOORCOVERING AND/OR BASE SHALL EXTEND INTO ANY CLOSETS, STORAGE AREAS, ETC.ADJACENT TO THAT SPACE UNLESS OTHERWISE NOTED.
REFER TO MANFACTURER'S GUIDELINES FOR FLOOR PREP AND INSTALLATION. ALLFLOORING ADHESIVES MUST MEET MANUFACTURER'S SPECIFICATIONS.
SUBMIT CARPET SEAMING PLAN PRIOR TO ORDERING FOR INTERIOR DESIGNER'S REVIEWAND APPROVAL.
REFER TO FLOOR PATTERN PLAN FOR ADDITIONAL INFORMATION (IF A FLOOR PATTERNPLAN IS INCLUDED IN THE DRAWINGS).
SEAM SEALING IS TO BE PROVIDED AT ALL CARPET EDGES. ALL EDGES CUT FORSEAMING MUST BE TREATED WITH A 1/8" BEAD OF CARPET SEAM SEALER. THE SEALERSHOULD BE APPLIED ALONG THE EDGE OF THE CARPET AT THE POINT WHERE THE FACEYARN GOES INTO THE BACK. ANY EXCESS SEALER WHICH CONTAMINATES THE CARPETFACT MUST BE REMOVED.
THE VINYL TILE SHALL BE INSTALLED IN THE BASKET WEAVE PATTERN. ACCENTS TOBE INSTALLED IN A UNI-DIRECTIONAL PATTERN.
LAY OUT TILES FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS,DISCOUNTING MINOR OFFSETS, SO TILES AT OPPOSITE EDGES OF ROOM ARE OF EQUALWIDTH. ADJUST AS NECESSARY TO AVOID USING CUT WIDTHS THAT EQUAL LESS THAN 1/2TILE AT PERIMETER,UNLESS OTHERWISE NOTED ON THE FLOOR PATTERN PLAN.
WHERE SPECIFIED IN THE FINISH SCHEDULE, SHEET VINYL FLOORING IS TO BE HEATWELDED AT SEAMS USING MANUFACTURER'S SEALER. REFER TO MANUFACTURER'SSPECIFICATIONS FOR RECOMMENDED CHANNEL DIMENSIONS.
ALL REDUCER STRIPS AND OTHER THRESHOLDS TO BE LOCATED AT CENTERLINE OFDOOR WHEN IN CLOSED POSITION.
RESILIENT FLOORING (1/8") TO CARPET (1/4") TRANSITION TO BE JOHNSONITE,SLT-29-A; COLOR: MOON ROCK. IT IS THE RESPONSIILITY OF THE CONTRACTOR TOVERIFY TRANSITION MODEL NUMBERS.
CARPET (1/4") TO CERAMIC TILE TRANSITION TO BE SCHLUTER, RENO-TK - ADACOMPLIANT. FINISH TO BE ANODIZED ALUMINUM. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO VERIFY TRANSITION MODEL NUMBERS.
PAINT ALL METAL UNDER COUNTER SUPPORTS TO MATCH ADJACENT WALL FINISHUNLESS OTHERWISE NOTED.
CAULK ALL PLUMBING FIXTURES, MILLWORK AND TRIM TO ADJACENT SURFACES. COLOROF CAULK TO BE CLEAR FINISH, UNLESS OTHERWISE NOTED.
FINISH SELECTION WILL BE MADE WITH SHOP DRAWINGS IF NOT NOTED ONCASEWORK ELEVATIONS.
WHEN INSTALLING LAY-IN CEILINGS, LAYOUT GRID IN ROOM SO CUT TILES AT PERIMETERARE NO LESS THAN 9" WIDE.
ALL EXPOSED FIELD CUT EDGES OF CEILING TILE SHALL BE REPAINTED TORESTORE ORIGINAL FINISH, PER MANUFACTURER'S RECOMMENDATIONS.
GYPSUM BOARD SOFFITS TO HAVE SAME FINISH AS ADJACENT WALL UNLESSOTHERWISE NOTED.
PAINT RETURN GRILLS, AIR SUPPLY GRILLS, AND ACCESS PANELS TO MATCHADJACENT CEILING FINISH.
ALL SURFACES SHALL BE PREPARED TO RECEIVE THE SPECIFIED FINISH. ALL GYPSUMBOARD SURFACES SHALL BE TAPED AND SANDED SMOOTH AND PREPARED TO RECEIVE THESPECIFIED FINISH. PAINT GRADE WOODWORK SHALL BE HAND SANDED BETWEEN COATS ANDDUSTED CLEAN. ALL HOLES, PITCH POCKETS OR SAPPY PORTIONS SHALL BE SCRAPED ANDSEALED. HAIL HOLES, CRACKS OR DEFECTS SHALL BE PUTTIED AFTER FIRST COAT, WITH PUTTYMATCHING COLOR OF STAIN OR PAINT FINISH. REMOVE OIL OR GREASE WITH MINERAL SPIRITS.
AC ACOUSTICAL CEILING TILEAF ATHLETIC FLOORINGCB CERAMIC BASECC CUBICLE CURTAINCF CORK FLOORINGCP CARPETFC FINISHED CONCRETECT CERAMIC TILEEC EXPOSED CEILINGEP EPOXY PAINTER EXISTING TO REMAINFRP FIBERGLASS REINFORCED PANELGYP GYPBOARD CEILINGME MATCH EXISTINGML METAL LAMINATENS NATURAL STONE SLABPL PLASTIC LAMINATEPT PAINT
RB RUBBER BASERF RESILIENT FLOORINGSB STONE BASESC SEALED CONCRETESF STONE FLOORINGSP SPECIALTY FINISHSS SOLID SURFACEST STAINLESS STEELVB SEAMED VINYL COVE BASEVF SEAMED VINYL FLOORINGWB WOOD BASEWC WALLCOVERINGWF WOOD FLOORWP WALL PROTECTIONWS WOOD STAINWT WALL TILEWV WOOD VENEERQT QUARTZ
GENERAL FINISH NOTES
FINISH LEGEND CEILING FINISHES
CEILING FINISH NOTES
WALL FINISHES
WALL FINISH NOTES
BASE FINISHES
FLOORING FINISHES
BASE & FLOORING NOTES
CASEWORK
CASEWORK NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
1.
2.
3.
4.
5.
1.
2.
3.
5.
1.
2.
3.
4.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
SHAW CONTRACTCARPET TILEEXPAND TILE 57059BURLAP 59706ASHLAR
CONTRACTOR TO PROVIDE MINIMUM 6' X 6' FINISHED CONCRETE SAMPLE(S) FORAPPROVAL ON SITE, IN AREA WHERE CONCRETE WILL BE COVERED WITH OTHERFLOORING MATERIAL. SAMPLES FOR APPROVAL SHOULD BE PROVIDED FOR ALL FINISHEDCONCRETE.
FINISHED CONCRETE FLOOR IS TO MEET COF MINIMUMS AS DESIGNATED HEREIN ASDICTATED BY ANSI A137.1 STANDARD AT OWNER POSSESION.
PROVIDE 2' X 4' PHONE BOARD TO BE NONCOMBUSTIBLE PLYWOOD PAINTED TO MATCHADJACENT WALL IN I.T. 102A.
12.
CEILING TRIM
MFG:STYLE:COLOR:NOTE:
ARMSTRONGAXIOM CLASSIC TRIM - 6"WHITECONTRACTOR RESPONSIBLE FORCORRECT TRIM MODEL NUMBER
ACOUSTICAL CEILING
MFG:STYLE:SIZE:COLOR:
ARMSTRONGDUNE TEGULAR24" X 24"WHITE
CEILING GRIDMFG:STYLE:COLOR:
ARMSTRONGPRELUDE 15/16"WHITE
AC2
PAINT
1 PRIMER COAT2 FINISH COATS
MFG:COLOR:FINISH:
PPGSHARKSKIN PPG0125-4LATEX EGG SHELL
PT2
PAINT
1 PRIMER COAT2 FINISH COATS
MFG:COLOR:FINISH:
PPGOFF THE GRID PPG1110-6LATEX EGG SHELL
PT3
WALL TILE
MFG:PATTERN:COLOR:SIZE:GROUT:JOINT SIZE:INSTALLATION:
DALTILEELEVAREMATTE LUNAR EL474" X 16"CBP; BRIGHT WHITE 3811/16"STRAIGHT LAY
WT2
PLASTIC LAMINATE
MFG:PATTERN:COLOR:FINISH:
TBD - PREMIUM GRADE PLASTIC LAMINATETBDTBDTBD
PL2
RUBBER BASE
MFG:STYLE:COLOR:HEIGHT:
MANNINGTONCONTINUOUS ROLL COVE BASESABLE 9116"
RB2
CERAMIC TILE
MFG:PATTERN:COLOR:SIZE:GROUT:JOINT SIZE:INSTALLATION:
LOUISVILLE TILEURBAN TIMBERASH6" X 24"MAPEI; SAHARA BEIGE 111/8"1/3 OFFSET
CT1
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
F100
16030.ID
FINISH SCHEDULE
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
No. REVISED DATE
FEC
CONFERENCE
104
OFFICE
105
OFFICE
106
OFFICE
107
ACCESSIBLERESTROOM
103
COPY/WORK
102
BISTRO
101
OPEN OFFICE
100
CORRIDOR
108
RF
CP
RF
CP
R 12' - 4"
CP
CT
1' - 3 1/2"
2 1/
2"
CP
CP
I.T.
102A
WT
2
WT
1
WC1
PT2
1
2
3334
1
5
5
6
GRAIN DIRECTION
CARPET ACCENT LINES
PT2PT2PT2
1
2
3
4
5
FINISH PLAN KEYNOTES
GYP1/AC1
PT1, 2
RB1
GYP1
RB1
CT1
AC2
RB1
CP2
AC1
PT1 RB1
RF1
CP1
PT1, 3/WT1
AC2
RB1
CP2PT2/WC1
6 GYP1
RB2
RF1PT1/WT2
NOTE: COVER ELECTRICAL PANEL WITH WC1. INSTALL SO THATDOOR OF PANEL FUNCTIONS PROPERTLY
PT1, 2
DRAWN:CHECKED:
4011 ARMORY OAKS DRIVENASHVILLE, TENNESSEE 37204(615) 833-8716 FAX: (615) 781-0493
Southeast VentureD E S I G N S E R V I C E S
PROJECT
SEAL
ISSUED DATE
1292
0 LE
BA
NO
N R
OA
DM
T. J
ULI
ET
, TN
371
22
JS
GC
F200
16030.ID
FINISH PLAN
ISSUED FOR CONSTRUCTION 06/03/2016
Ban
k of
Ten
ness
ee -
Mt.
Julie
t
1/4" = 1'-0"1 FINISH PLAN
No. REVISED DATE