it greening

13
IT Greening Computer Power Consumption Study Christian Grieco Time Warner Cable Christian.grieco@twcable. com

Upload: valin

Post on 07-Jan-2016

38 views

Category:

Documents


0 download

DESCRIPTION

Computer Power Consumption Study. Christian Grieco Time Warner Cable [email protected]. IT Greening. Purpose of Study. Ascertain an estimate of expenditure on electricity to power staff computer infrastructure - PowerPoint PPT Presentation

TRANSCRIPT

IT Greening

Computer Power ConsumptionStudy

Christian GriecoTime Warner [email protected]

Purpose of Study

• Ascertain an estimate of expenditure on electricity to power staff computer infrastructure

• Determine $ savings potential in implementing various measures to improve efficiency without affecting productivity

DOE & EPA Computer Electricity Research

• $25 - $75 savings per computer per year• 39% of computers in businesses are left powered

on overnight and weekends• Study translates to savings of $13,750 - $41,250

yearly on DESKTOPS alone • Laptop savings not estimated as part of this study

Estimate of PC Inventory

550 Desktops

420 Laptops

750 Flat Screen monitors

? CRT monitors

• 550 Desktops

• 420 Laptops

• 750 Flat Screen monitors

• ? CRT monitors

Methodology• Use Kill A Watt device to measure actual

electricity consumption of desktop and laptop computer

• Measure usage• no power savings 24 hours• no power savings 8.5 hours• power savings 24 hours• power savings 8.5 hours

Business Class Laptop

Device Power Draw ( in watts)

Laptop 17

Monitor 26

Printer Standby

11

Printer Printing 530

Business Class Desktop

DevicePower Draw ( in

watts)

Desktop 68

Monitor 24

Business Class

Desktops Laptops Flat screens

Business Class Laptop

TimeframePower

Consumption

24 hours 1.40 kWh

8.5 hours .49 kWh

Non business hours

.91 kWh

Power off the machine to realize 65% savings

Even with no power saving features set

Business Class Desktop - NO Power Savings

TimeframePower

Consumption

24 hours 1.77 kWh

8.5 hours 1.00 kWh

Non business hours

.77 kWh

Power off the machine to realize 44% savings

Even with no power saving features set

Business Class Desktop With Power Savings Features

TimeframePower

ConsumedSavings usingPower Savings

Combined Savings

24 hours 1.04 kWh .73 kWh

8.5 hours .81 kWh .19 kWh .96 kWhNon

business hours

.23 kWh .54 kWh

Enable Power Savings & Power Off to realize 54 % Savings

Telemarketing

Desktops Laptops Flat screens

Estimated Yearly Savings Potential

off @ night 3 weeks per month 10 out of 12 monthsbased on 550 desktop computers with ONE monitor

Eliminate212,982 pounds of CO2

EstimatedTotalExpenditureon Power

Generates408,870poundsCO2