CitiWest Consulting Ltd. - Civil Engineers #101 - 9030 King George Blvd., Surrey, B.C. V3V 7Y3 Tel: 604-591-2213 Fax: 604-591-5518 e-mail: [email protected] • www.citiwest.com
January 10, 2020
File: 19-3988 City of Vancouver Development and Building Services Centre Ground Floor, 515 W. 10 Avenue Vancouver, BC V5Z 4A8 Attn: Yan Zeng Dear Madam:
Re: 3353 Cambie Street, Vancouver
Rainwater Management Plan We have prepared this Rainwater Management Plan for this commercial development at 3353 Cambie Street, Vancouver, to comply with the Green Building Policy for Rezoning (Green Infrastructure Implementation Plan). System Summary The system is designed so that no additional on-site storm water will be discharged to the municipal system. This is achieved by a combination of methods that fall under Tiers 1, 2 and 3. Below are the Criteria used to determine the Rainwater Management Plan and the most stringent Criteria will be implemented at the site. 1. Retain the first 24mm of rainfall in 24 hours as listed in the Rainwater Management
Bulletin in effect since July 11, 2018. 2. Control the 5-year post-development flow to 5-year pre-development flow rate (use
2014 IDF 5-year storm event rate as pre-development and 2100 IDF 5-year storm event rate as post-development condition).
3. LEED v4 (85th percentile storm event detained).
CRITERIA DESCRIPTION VOLUME REQUIRED
1 Retain the first 24mm of rainfall in 24 hours 20.82 m3.
2 Control the 5-year, 24-hr 2014 post-development flow to 5-year 24-hr 2100 post-development flow rate
4.26 m3.
3 LEED v4 (85th percentile storm event detained)
17.88 m3.
Rainwater detention for Criteria 1 is the worst case. Thus, by addressing Criteria 1, all the remaining Criteria will be automatically addressed. An oil interceptor is added to the onsite system to achieve the 80% TSS removal as per the Rainwater Management Bulletin dated July 11, 2018.
H:\Projects\3988\Docs\200110 Rainwater Mgmt Letter.docx 2
System Based on VanMap orthophotos, the pre-development site is almost at 100% hard surface with an asphalt parking lot to the west and a relatively flat building roof to the east. Please refer to Figure 1, 2016 Orthophotos and Figure 2, 1999 Orthophotos in Appendix 1. The Preliminary Rainwater Management Plan is prepared based on the architectural layout prepared by Radiant City Architecture Inc., dated December 13, 2019, and in the absence of the onsite landscape drawing. Based on the current architectural layout and discussion with the architect, the outdoor space for the daycare on the second floor can be covered with topsoil and sod. (Tier 1). Rainwater falling on the covered outdoor area on the second floor can be directed to the landscaped area. (Tier 2). The roof drain will be directed to a stormwater detention system and the maximum release rate will be set to the pre-development rate at 0.0095 cu. m/s to satisfy City requirements. For an extreme storm event, stormwater on the second floor will be directed to the area drain in the landscaped area, which will be set 0.03m higher than the sod elevation to collect the flow. Stormwater will then be directed to the oil interceptor. A bypass system will be used to safely release the overflow to the municipal system to prevent flooding of the development. As per the water quality requirements, water (24mm for low pollutant generating surfaces like roofs, and 48mm for high pollutant generating surfaces like driveways) that leaves the site must be treated to a standard of 80% TSS removal. All water leaving the site will first be directed to a stormceptor unit to remove a minimum of 80% TSS. The proposed location of the stormceptor unit and model number has been provided in Appendix 1. The location will be confirmed during in the DP stage. A Section 219 Rainwater Management Agreement Covenant will be required once the Final RWMP is accepted by the City. The Final RWMP will be attached to the covenant and be registered on the property’s title. After construction, the Engineer of Record will be required to inspect the RWM system and determine whether it has been substantially completed according to the covenant and Final RWM plan. Please let me know if you have any questions. Yours truly, CitiWest Consulting Ltd. Peter Yue, P. Eng. Project Engineer PY/py Attach.
Appendix 1
H:\Projects\3988\Docs\200110 Rainwater Mgmt Letter.docx
Pre-Development Site Plan
Figure 1. 2016 Orthophotos from City of Vancouver Legacy VanMap.
Figure 2. 1999 Orthophotos from City of Vancouver Legacy VanMap.
H:\Projects\3988\Docs\200110 Rainwater Mgmt Letter.docx
Pre-Development Site Drainage
Figure 3. Pre-Development Site Drainage –
City of Vancouver VanMap Infrastructure Viewer
H:\Projects\3988\Docs\200110 Rainwater Mgmt Letter.docx
Calculation
Site Location: 3353 Cambie Street Total Site Area: 868 m2 Pre-development run-off coefficient calculation Parking lot 503.3 m2
Roof 364.7 m2
Total 868.0 m2
Average Runoff coefficient for the site = [503.3 x 0.8 + 364.7 x 0.85] / 868 = 0.821 Proposed development run-off coefficient calculation Landscape area on ground level: 0 m2 Patio and other hardscape area fronting Cambie Street: 73.58 m2 Patio and other hardscape area on second floor: 114.04 m2
Landscape area on second floor: 219.88 m2 Rooftop at 6th level area: 448.24 m2 Hardscape fronting Tupper Street 12.26 m2 Total Site Area: 868 m2
Average Runoff coefficient for the site = [73.58 x 0.8 + 114.04 x 0.85 + 219.88 x 0.18 + 448.24 x 0.85 + 12.26 x 0.8] / 868 = 0.6753 Criteria 1 24mm x (868m2) = 20.832 m3
Criteria 2 Refer to the excel = 4.256 m3
Criteria 3 20.6mm x (868m2) = 17.88 m3
Rainwater detention for Criteria 1 is the worst case. Thus, by addressing Criteria 1, all the remaining Criteria will be automatically addressed.
Rainwater retention (landscape on slab) Landscape area on second floor = 219.88 m2 Soil depth = 450mm Void ratio for topsoil = 0.25 Volume in soil for retention = 219.88 m3 x 0.45 x 0.25 = 24.74 m3
24.74 m3> 20.83m3 (Criteria 1)
Landscape on slab (second floor) is capable of retaining the required volume.
H:\Projects\3988\Docs\200110 Rainwater Mgmt Letter.docx
Release Rate The rainfall intensity, I, is based on the City of Vancouver Intensity Duration Frequency (IDF) curves and the 5-year 10-minute duration to be 48mm/hr.
Area of the site = 868 m2
Pre-development runoff coefficient = 0.82 Q5 (pre-development for 10-min event) = (0.82 x 48mm x 0.868 ha)/3600 = 9.49 L/s. Maximum release rate for post-development is set at 9.49 L/s.
Project No. 3988
Client 3353 Cambie Street, Vancouver
Date January 8, 2020 (*) - Type II distribution per southwest BC
Description Criteria 2 calculation
Comments Control the 5-year post development flow to 5-year pre-development flow rate.
(use 2014 IDF 5-year storm event rate as pre-development and 2100 IDF 5-year storm event rate as Post-development condition).
Site area to detain (Ha)= 0.0868
Vancouver 2014 Time/Intensity Curve: Vancouver 2100 Climate Change Time/Intensity Curve:
Time Intensity (*) Area Runoff Coeff Q in Q out Q det Time Intensity (*) Area Runoff Coeff Q in Q out Q det
min mm/hr Ha R m3/sec m3/sec m3 min mm/hr Ha R m3/sec m3/sec m3
5Yr 2hr 5Yr 2hr (2014 out)
0 0.0868 0.82 0 0 0 0.0868 0.65 0 0
5 8.35 0.0868 0.82 0.001651 0.001651 0 5 10.90 0.0868 0.65 0.001708 0.001651 0.017055
10 8.35 0.0868 0.82 0.001651 0.001651 0 10 10.90 0.0868 0.65 0.001708 0.001651 0.017055
15 10.02 0.0868 0.82 0.001981 0.001981 0 15 13.08 0.0868 0.65 0.002049 0.001981 0.02046
20 10.02 0.0868 0.82 0.001981 0.001981 0 20 13.08 0.0868 0.65 0.002049 0.001981 0.02046
25 15.04 0.0868 0.82 0.002973 0.002973 0 25 19.62 0.0868 0.65 0.003075 0.002973 0.030704
30 15.04 0.0868 0.82 0.002973 0.002973 0 30 19.62 0.0868 0.65 0.003075 0.002973 0.030704
35 15.04 0.0868 0.82 0.002973 0.002973 0 35 19.62 0.0868 0.65 0.003075 0.002973 0.030704
40 15.04 0.0868 0.82 0.002973 0.002973 0 40 19.62 0.0868 0.65 0.003075 0.002973 0.030704
45 16.70 0.0868 0.82 0.003303 0.003303 0 45 21.80 0.0868 0.65 0.003416 0.003303 0.034109
50 16.70 0.0868 0.82 0.003303 0.003303 0 50 21.80 0.0868 0.65 0.003416 0.003303 0.034109
55 18.37 0.0868 0.82 0.003632 0.003632 0 55 23.97 0.0868 0.65 0.003757 0.003632 0.037515
60 18.37 0.0868 0.82 0.003632 0.003632 0 60 23.97 0.0868 0.65 0.003757 0.003632 0.037515
65 23.39 0.0868 0.82 0.004624 0.004624 0 65 30.52 0.0868 0.65 0.004783 0.004624 0.047758
70 23.39 0.0868 0.82 0.004624 0.004624 0 70 30.52 0.0868 0.65 0.004783 0.004624 0.047758
75 18.37 0.0868 0.82 0.003632 0.003632 0 75 23.97 0.0868 0.65 0.003757 0.003632 0.037515
80 18.37 0.0868 0.82 0.003632 0.003632 0 80 23.97 0.0868 0.65 0.003757 0.003632 0.037515
85 13.37 0.0868 0.82 0.002643 0.002643 0 85 17.45 0.0868 0.65 0.002734 0.002643 0.027298
90 13.37 0.0868 0.82 0.002643 0.002643 0 90 17.45 0.0868 0.65 0.002734 0.002643 0.027298
95 11.67 0.0868 0.82 0.002308 0.002308 0 95 15.23 0.0868 0.65 0.002388 0.002308 0.023839
100 11.67 0.0868 0.82 0.002308 0.002308 0 100 15.23 0.0868 0.65 0.002388 0.002308 0.023839
105 10.02 0.0868 0.82 0.001981 0.001981 0 105 13.08 0.0868 0.65 0.002049 0.001981 0.02046
110 10.02 0.0868 0.82 0.001981 0.001981 0 110 13.08 0.0868 0.65 0.002049 0.001981 0.02046
115 6.68 0.0868 0.82 0.001322 0.001322 0 115 8.72 0.0868 0.65 0.001367 0.001322 0.013649
120 6.68 0.0868 0.82 0.001322 0.001322 0 120 8.72 0.0868 0.65 0.001367 0.001322 0.013649
0 0 0.0868
27.84 mm 0 36.33 mm Detained Volume (m^3)= 0.682127
2014 5-YEAR 2 HR PRE VS 2100 5-YEAR POST 2 HR
CRITERIA 2
Project No. 3988
Client 3353 Cambie Street, Vancouver
Date January 8, 2020 (*) - Type II distribution per southwest BC
Description Criteria 2 calculation
Comments Control the 5-year post development flow to 5-year pre-development flow rate.
(use 2014 IDF 5-year storm event rate as pre-development and 2100 IDF 5-year storm event rate as Post-development condition).
Site area to detain (Ha)= 0.0868
Vancouver 2014 Time/Intensity Curve: Vancouver 2100 Climate Change Time/Intensity Curve:
Time Intensity (*) Area Runoff Coeff Q in Q out Q det Time Intensity (*) Area Runoff Coeff Q in Q out Q det
min mm/hr Ha R m3/sec m3/sec m3 min mm/hr Ha R m3/sec m3/sec m3
5Yr 6hr 5Yr 6hr (2014 out)
0 0.0868 0.821 0 0 0 0.0868 0.6753 0 0
10 5.54 0.0868 0.821 0.001097 0.001097 0 10 7.21 0.0868 0.6753 0.001175 0.001097 0.046742
20 5.54 0.0868 0.821 0.001097 0.001097 0 20 7.21 0.0868 0.6753 0.001175 0.001097 0.046742
30 5.54 0.0868 0.821 0.001097 0.001097 0 30 7.21 0.0868 0.6753 0.001175 0.001097 0.046742
40 6.46 0.0868 0.821 0.001279 0.001279 0 40 8.41 0.0868 0.6753 0.001369 0.001279 0.054484
50 6.48 0.0868 0.821 0.001283 0.001283 0 50 8.44 0.0868 0.6753 0.001374 0.001283 0.054678
60 6.46 0.0868 0.821 0.001279 0.001279 0 60 8.41 0.0868 0.6753 0.001369 0.001279 0.054484
70 8.33 0.0868 0.821 0.001649 0.001649 0 70 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
80 8.33 0.0868 0.821 0.001649 0.001649 0 80 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
90 8.33 0.0868 0.821 0.001649 0.001649 0 90 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
100 7.40 0.0868 0.821 0.001465 0.001465 0 100 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
110 7.39 0.0868 0.821 0.001462 0.001462 0 110 9.62 0.0868 0.6753 0.001566 0.001462 0.062323
120 7.40 0.0868 0.821 0.001465 0.001465 0 120 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
130 7.50 0.0868 0.821 0.001485 0.001485 0 130 9.77 0.0868 0.6753 0.001591 0.001485 0.063291
140 7.39 0.0868 0.821 0.001462 0.001462 0 140 9.62 0.0868 0.6753 0.001566 0.001462 0.062323
150 7.40 0.0868 0.821 0.001465 0.001465 0 150 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
160 11.09 0.0868 0.821 0.002196 0.002196 0 160 14.44 0.0868 0.6753 0.002352 0.002196 0.093581
170 11.09 0.0868 0.821 0.002196 0.002196 0 170 14.44 0.0868 0.6753 0.002352 0.002196 0.093581
180 11.09 0.0868 0.821 0.002196 0.002196 0 180 14.44 0.0868 0.6753 0.002352 0.002196 0.093581
190 8.33 0.0868 0.821 0.001649 0.001649 0 190 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
200 8.33 0.0868 0.821 0.001649 0.001649 0 200 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
210 8.33 0.0868 0.821 0.001649 0.001649 0 210 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
220 8.33 0.0868 0.821 0.001649 0.001649 0 220 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
230 8.33 0.0868 0.821 0.001649 0.001649 0 230 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
240 8.33 0.0868 0.821 0.001649 0.001649 0 240 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
250 8.33 0.0868 0.821 0.001649 0.001649 0 250 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
260 8.33 0.0868 0.821 0.001649 0.001649 0 260 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
270 8.33 0.0868 0.821 0.001649 0.001649 0 270 10.84 0.0868 0.6753 0.001766 0.001649 0.070258
280 7.40 0.0868 0.821 0.001465 0.001465 0 280 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
290 7.39 0.0868 0.821 0.001462 0.001462 0 290 9.62 0.0868 0.6753 0.001566 0.001462 0.062323
300 7.40 0.0868 0.821 0.001465 0.001465 0 300 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
310 7.40 0.0868 0.821 0.001465 0.001465 0 310 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
320 7.39 0.0868 0.821 0.001462 0.001462 0 320 9.62 0.0868 0.6753 0.001566 0.001462 0.062323
330 7.40 0.0868 0.821 0.001465 0.001465 0 330 9.63 0.0868 0.6753 0.001569 0.001465 0.06242
340 6.46 0.0868 0.821 0.001279 0.001279 0 340 8.41 0.0868 0.6753 0.001369 0.001279 0.054484
350 6.46 0.0868 0.821 0.001279 0.001279 0 350 8.41 0.0868 0.6753 0.001369 0.001279 0.054484
360 6.46 0.0868 0.821 0.001279 0.001279 0 360 8.41 0.0868 0.6753 0.001369 0.001279 0.054484
46.25 mm Detained Volume (m^3)= 0 60.22 mm Detained Volume (m^3)= 2.340684
*Max volume*
2014 5-YEAR 6 HR PRE VS 2100 5-YEAR POST 6 HR
CRITERIA 2
Project No. 3988
Client 3353 Cambie Street, Vancouver
Date January 8, 2020 (*) - Type II distribution per southwest BC
Description Criteria 2 calculation
Comments Control the 5-year post development flow to 5-year pre-development flow rate.
(use 2014 IDF 5-year storm event rate as pre-development and 2100 IDF 5-year storm event rate as Post-development condition).
Site area to detain (Ha)= 0.0868
Vancouver 2014 Time/Intensity Curve: Vancouver 2100 Climate Change Time/Intensity Curve:
Time Intensity (*) Area Runoff Coeff Q in Q out Q det Time Intensity (*) Area Runoff Coeff Q in Q out Q det
min mm/hr Ha R m3/sec m3/sec m3 min mm/hr Ha R m3/sec m3/sec m3
5yr 12hr 5yr 12hr (2014 out)
0 0.0868 0.821 0 0 0 0.0868 0.6753 0 0
10 2.54 0.0868 0.821 0.000504 0.000504 0 10 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
20 2.54 0.0868 0.821 0.000504 0.000504 0 20 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
30 2.54 0.0868 0.821 0.000504 0.000504 0 30 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
40 3.19 0.0868 0.821 0.000631 0.000631 0 40 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
50 3.19 0.0868 0.821 0.000631 0.000631 0 50 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
60 3.19 0.0868 0.821 0.000631 0.000631 0 60 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
70 3.83 0.0868 0.821 0.000758 0.000758 0 70 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
80 3.83 0.0868 0.821 0.000758 0.000758 0 80 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
90 3.83 0.0868 0.821 0.000758 0.000758 0 90 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
100 4.46 0.0868 0.821 0.000882 0.000882 0 100 5.80 0.0868 0.6753 0.000944 0.000882 0.036818
110 4.46 0.0868 0.821 0.000882 0.000882 0 110 5.80 0.0868 0.6753 0.000944 0.000882 0.036818
120 4.46 0.0868 0.821 0.000882 0.000882 0 120 5.80 0.0868 0.6753 0.000944 0.000882 0.036818
130 5.73 0.0868 0.821 0.001134 0.001134 0 130 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
140 5.73 0.0868 0.821 0.001134 0.001134 0 140 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
150 5.73 0.0868 0.821 0.001134 0.001134 0 150 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
160 7.64 0.0868 0.821 0.001513 0.001513 0 160 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
170 7.64 0.0868 0.821 0.001513 0.001513 0 170 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
180 7.64 0.0868 0.821 0.001513 0.001513 0 180 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
190 10.83 0.0868 0.821 0.002144 0.002144 0 190 14.08 0.0868 0.6753 0.002293 0.002144 0.089441
200 10.83 0.0868 0.821 0.002144 0.002144 0 200 14.08 0.0868 0.6753 0.002293 0.002144 0.089441
210 10.83 0.0868 0.821 0.002144 0.002144 0 210 14.08 0.0868 0.6753 0.002293 0.002144 0.089441
220 13.38 0.0868 0.821 0.002649 0.002649 0 220 17.40 0.0868 0.6753 0.002834 0.002649 0.110541
230 13.38 0.0868 0.821 0.002649 0.002649 0 230 17.40 0.0868 0.6753 0.002834 0.002649 0.110541
240 13.38 0.0868 0.821 0.002649 0.002649 0 240 17.40 0.0868 0.6753 0.002834 0.002649 0.110541
250 10.20 0.0868 0.821 0.002019 0.002019 0 250 13.26 0.0868 0.6753 0.002159 0.002019 0.08423
260 10.20 0.0868 0.821 0.002019 0.002019 0 260 13.26 0.0868 0.6753 0.002159 0.002019 0.08423
270 10.20 0.0868 0.821 0.002019 0.002019 0 270 13.26 0.0868 0.6753 0.002159 0.002019 0.08423
280 8.27 0.0868 0.821 0.001638 0.001638 0 280 10.76 0.0868 0.6753 0.001752 0.001638 0.068341
290 8.27 0.0868 0.821 0.001638 0.001638 0 290 10.76 0.0868 0.6753 0.001752 0.001638 0.068341
300 8.27 0.0868 0.821 0.001638 0.001638 0 300 10.76 0.0868 0.6753 0.001752 0.001638 0.068341
310 7.64 0.0868 0.821 0.001513 0.001513 0 310 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
320 7.64 0.0868 0.821 0.001513 0.001513 0 320 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
330 7.64 0.0868 0.821 0.001513 0.001513 0 330 9.94 0.0868 0.6753 0.001618 0.001513 0.06313
340 6.37 0.0868 0.821 0.001261 0.001261 0 340 8.28 0.0868 0.6753 0.001349 0.001261 0.052622
350 6.37 0.0868 0.821 0.001261 0.001261 0 350 8.28 0.0868 0.6753 0.001349 0.001261 0.052622
360 6.37 0.0868 0.821 0.001261 0.001261 0 360 8.28 0.0868 0.6753 0.001349 0.001261 0.052622
370 5.10 0.0868 0.821 0.001009 0.001009 0 370 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
380 5.10 0.0868 0.821 0.001009 0.001009 0 380 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
390 5.10 0.0868 0.821 0.001009 0.001009 0 390 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
400 5.73 0.0868 0.821 0.001134 0.001134 0 400 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
410 5.73 0.0868 0.821 0.001134 0.001134 0 410 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
420 5.73 0.0868 0.821 0.001134 0.001134 0 420 7.45 0.0868 0.6753 0.001213 0.001134 0.047326
430 3.83 0.0868 0.821 0.000758 0.000758 0 430 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
440 3.83 0.0868 0.821 0.000758 0.000758 0 440 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
450 3.83 0.0868 0.821 0.000758 0.000758 0 450 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
460 5.10 0.0868 0.821 0.001009 0.001009 0 460 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
470 5.10 0.0868 0.821 0.001009 0.001009 0 470 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
480 5.10 0.0868 0.821 0.001009 0.001009 0 480 6.63 0.0868 0.6753 0.00108 0.001009 0.042115
490 3.83 0.0868 0.821 0.000758 0.000758 0 490 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
500 3.83 0.0868 0.821 0.000758 0.000758 0 500 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
510 3.83 0.0868 0.821 0.000758 0.000758 0 510 4.98 0.0868 0.6753 0.00081 0.000758 0.031608
520 3.19 0.0868 0.821 0.000631 0.000631 0 520 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
530 3.19 0.0868 0.821 0.000631 0.000631 0 530 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
540 3.19 0.0868 0.821 0.000631 0.000631 0 540 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
550 2.54 0.0868 0.821 0.000504 0.000504 0 550 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
560 2.54 0.0868 0.821 0.000504 0.000504 0 560 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
570 2.54 0.0868 0.821 0.000504 0.000504 0 570 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
580 3.19 0.0868 0.821 0.000631 0.000631 0 580 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
590 3.19 0.0868 0.821 0.000631 0.000631 0 590 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
600 3.19 0.0868 0.821 0.000631 0.000631 0 600 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
610 2.54 0.0868 0.821 0.000504 0.000504 0 610 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
620 2.54 0.0868 0.821 0.000504 0.000504 0 620 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
630 2.54 0.0868 0.821 0.000504 0.000504 0 630 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
640 2.54 0.0868 0.821 0.000504 0.000504 0 640 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
650 2.54 0.0868 0.821 0.000504 0.000504 0 650 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
660 2.54 0.0868 0.821 0.000504 0.000504 0 660 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
670 3.19 0.0868 0.821 0.000631 0.000631 0 670 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
680 3.19 0.0868 0.821 0.000631 0.000631 0 680 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
690 3.19 0.0868 0.821 0.000631 0.000631 0 690 4.14 0.0868 0.6753 0.000674 0.000631 0.026311
700 2.54 0.0868 0.821 0.000504 0.000504 0 700 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
710 2.54 0.0868 0.821 0.000504 0.000504 0 710 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
720 2.54 0.0868 0.821 0.000504 0.000504 0 720 3.31 0.0868 0.6753 0.000539 0.000504 0.021015
63.70 mm 0 82.83 mm Detained Volume (m^3)= 3.156821
2014 5-YEAR 12 HR PRE VS 2100 5-YEAR POST 12 HR
CRITERIA 2
Project No. 3988
Client 3353 Cambie Street, Vancouver
Date January 8, 2020 (*) - Type II distribution per southwest BC
Description Criteria 2 calculation
Comments Control the 5-year post development flow to 5-year pre-development flow rate.
(use 2014 IDF 5-year storm event rate as pre-development and 2100 IDF 5-year storm event rate as Post-development condition).
Site area to detain (Ha)= 0.0868
Vancouver 2014 Time/Intensity Curve: Vancouver 2100 Climate Change Time/Intensity Curve:
Time Intensity (*) Area Runoff Coeff Q in Q out Q det Time Intensity (*) Area Runoff Coeff Q in Q out Q det
min mm/hr Ha R m3/sec m3/sec m3 min mm/hr Ha R m3/sec m3/sec m3
5yr 24hr 5yr 24hr (2014 out)
0 0.0868 0.821 0 0 0 0.0868 0.6753 0 0
20 1.75 0.0868 0.821 0.000347 0.000347 0 20 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
40 1.75 0.0868 0.821 0.000347 0.000347 0 40 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
60 1.75 0.0868 0.821 0.000347 0.000347 0 60 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
80 2.19 0.0868 0.821 0.000434 0.000434 0 80 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
100 2.19 0.0868 0.821 0.000434 0.000434 0 100 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
120 2.19 0.0868 0.821 0.000434 0.000434 0 120 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
140 2.64 0.0868 0.821 0.000522 0.000522 0 140 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
160 2.64 0.0868 0.821 0.000522 0.000522 0 160 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
180 2.64 0.0868 0.821 0.000522 0.000522 0 180 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
200 3.07 0.0868 0.821 0.000607 0.000607 0 200 3.98 0.0868 0.6753 0.000649 0.000607 0.049592
220 3.07 0.0868 0.821 0.000607 0.000607 0 220 3.98 0.0868 0.6753 0.000649 0.000607 0.049592
240 3.07 0.0868 0.821 0.000607 0.000607 0 240 3.98 0.0868 0.6753 0.000649 0.000607 0.049592
260 3.94 0.0868 0.821 0.000781 0.000781 0 260 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
280 3.94 0.0868 0.821 0.000781 0.000781 0 280 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
300 3.94 0.0868 0.821 0.000781 0.000781 0 300 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
320 5.26 0.0868 0.821 0.001041 0.001041 0 320 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
340 5.26 0.0868 0.821 0.001041 0.001041 0 340 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
360 5.26 0.0868 0.821 0.001041 0.001041 0 360 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
380 7.46 0.0868 0.821 0.001477 0.001477 0 380 9.69 0.0868 0.6753 0.001577 0.001477 0.120603
400 7.46 0.0868 0.821 0.001477 0.001477 0 400 9.69 0.0868 0.6753 0.001577 0.001477 0.120603
420 7.46 0.0868 0.821 0.001477 0.001477 0 420 9.69 0.0868 0.6753 0.001577 0.001477 0.120603
440 9.21 0.0868 0.821 0.001824 0.001824 0 440 11.96 0.0868 0.6753 0.001948 0.001824 0.148942
460 9.21 0.0868 0.821 0.001824 0.001824 0 460 11.96 0.0868 0.6753 0.001948 0.001824 0.148942
480 9.21 0.0868 0.821 0.001824 0.001824 0 480 11.96 0.0868 0.6753 0.001948 0.001824 0.148942
500 7.02 0.0868 0.821 0.00139 0.00139 0 500 9.12 0.0868 0.6753 0.001485 0.00139 0.113519
520 7.02 0.0868 0.821 0.00139 0.00139 0 520 9.12 0.0868 0.6753 0.001485 0.00139 0.113519
540 7.02 0.0868 0.821 0.00139 0.00139 0 540 9.12 0.0868 0.6753 0.001485 0.00139 0.113519
560 5.71 0.0868 0.821 0.00113 0.00113 0 560 7.41 0.0868 0.6753 0.001207 0.00113 0.092265
580 5.71 0.0868 0.821 0.00113 0.00113 0 580 7.41 0.0868 0.6753 0.001207 0.00113 0.092265
600 5.71 0.0868 0.821 0.00113 0.00113 0 600 7.41 0.0868 0.6753 0.001207 0.00113 0.092265
620 5.26 0.0868 0.821 0.001041 0.001041 0 620 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
640 5.26 0.0868 0.821 0.001041 0.001041 0 640 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
660 5.26 0.0868 0.821 0.001041 0.001041 0 660 6.83 0.0868 0.6753 0.001112 0.001041 0.085015
680 4.39 0.0868 0.821 0.000869 0.000869 0 680 5.70 0.0868 0.6753 0.000929 0.000869 0.071011
700 4.39 0.0868 0.821 0.000869 0.000869 0 700 5.70 0.0868 0.6753 0.000929 0.000869 0.071011
720 4.39 0.0868 0.821 0.000869 0.000869 0 720 5.70 0.0868 0.6753 0.000929 0.000869 0.071011
740 3.52 0.0868 0.821 0.000696 0.000696 0 740 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
760 3.52 0.0868 0.821 0.000696 0.000696 0 760 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
780 3.52 0.0868 0.821 0.000696 0.000696 0 780 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
800 3.94 0.0868 0.821 0.000781 0.000781 0 800 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
820 3.94 0.0868 0.821 0.000781 0.000781 0 820 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
840 3.94 0.0868 0.821 0.000781 0.000781 0 840 5.12 0.0868 0.6753 0.000834 0.000781 0.063762
860 2.64 0.0868 0.821 0.000522 0.000522 0 860 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
880 2.64 0.0868 0.821 0.000522 0.000522 0 880 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
900 2.64 0.0868 0.821 0.000522 0.000522 0 900 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
920 3.52 0.0868 0.821 0.000696 0.000696 0 920 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
940 3.52 0.0868 0.821 0.000696 0.000696 0 940 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
960 3.52 0.0868 0.821 0.000696 0.000696 0 960 4.57 0.0868 0.6753 0.000743 0.000696 0.056842
980 2.64 0.0868 0.821 0.000522 0.000522 0 980 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
1000 2.64 0.0868 0.821 0.000522 0.000522 0 1000 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
1020 2.64 0.0868 0.821 0.000522 0.000522 0 1020 3.43 0.0868 0.6753 0.000558 0.000522 0.042672
1040 2.19 0.0868 0.821 0.000434 0.000434 0 1040 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1060 2.19 0.0868 0.821 0.000434 0.000434 0 1060 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1080 2.19 0.0868 0.821 0.000434 0.000434 0 1080 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1100 1.75 0.0868 0.821 0.000347 0.000347 0 1100 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1120 1.75 0.0868 0.821 0.000347 0.000347 0 1120 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1140 1.75 0.0868 0.821 0.000347 0.000347 0 1140 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1160 2.19 0.0868 0.821 0.000434 0.000434 0 1160 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1180 2.19 0.0868 0.821 0.000434 0.000434 0 1180 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1200 2.19 0.0868 0.821 0.000434 0.000434 0 1200 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1220 1.75 0.0868 0.821 0.000347 0.000347 0 1220 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1240 1.75 0.0868 0.821 0.000347 0.000347 0 1240 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1260 1.75 0.0868 0.821 0.000347 0.000347 0 1260 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1280 1.75 0.0868 0.821 0.000347 0.000347 0 1280 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1300 1.75 0.0868 0.821 0.000347 0.000347 0 1300 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1320 1.75 0.0868 0.821 0.000347 0.000347 0 1320 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1340 2.19 0.0868 0.821 0.000434 0.000434 0 1340 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1360 2.19 0.0868 0.821 0.000434 0.000434 0 1360 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1380 2.19 0.0868 0.821 0.000434 0.000434 0 1380 2.85 0.0868 0.6753 0.000463 0.000434 0.035423
1400 1.75 0.0868 0.821 0.000347 0.000347 0 1400 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1420 1.75 0.0868 0.821 0.000347 0.000347 0 1420 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
1440 1.75 0.0868 0.821 0.000347 0.000347 0 1440 2.28 0.0868 0.6753 0.000371 0.000347 0.028338
87.75 mm 0 113.94 mm Detained Volume (m^3)= 4.255715
2014 5-YEAR 24 HR PRE VS 2100 5-YEAR POST 24 HR
CRITERIA 2
3345
3377
Ca
mbi
e S
t.
Tup
per
St.
W 17th Ave
W 18th Ave
3353
Pro
pert
y lin
e
Pro
pert
y lin
e
Bui
ldin
g lin
e
True
Property line
Property line
Residentialabove retail
CourtyardResidential
aboveparking
4
AC-5.0
3
AC-5.0
DN 10%
-16' - 7"
UP10%
Pro
pert
y lin
e
Pro
pert
y lin
e
Property line
Property line
10%
3
2
DN4
End of tripbathroom
-12' - 10"
10' - 0"
141' - 10"
Stair 1
Bui
ldin
g lin
e
13%
53' - 5"13' - 0"40' - 6" 24' - 11"
66' -
0"
131' - 10"
Daycaredrop off
11 Class Abicycles
Stair 2 Class Bloading
Class Aloading
Garbage/recycling
1
5
6
7
8
Daycaredrop off
Daycaredrop off
Mechanical
4
AC-5.0
3
AC-5.0
Pro
pert
y lin
e
Pro
pert
y lin
e
10
9
11
12
13
Property line
14
Mechanical
17
16
18
19
20
21
22
Mechanical
DN10%
UP10%
10' - 0"
141' - 10"
Stair 1
Bui
ldin
g lin
e
10%DN
66' -
0"
131' - 10"
Property line
-25' - 1" -21' - 0"
Stair 2
15
Storage
40' - 6" 44' - 2" 47' - 2"
4
AC-5.0
3
AC-5.0
Pro
pert
y lin
e
Pro
pert
y lin
e
Property line
Property line
24
23
25
26
27
2831
30
32
33
34
35
36
MechanicalMechanical
UP
10' - 0"
141' - 10"
Stair 1
Bui
ldin
g lin
e
47' - 2"
10%DN
10%
41' - 2"
66' -
0"
131' - 10"
Stair 2
29
-33' - 3" -29' - 2"
Storage
43' - 6"
Scale
Drawing Notes
1. This drawing reflects the intent of the design. Verify existing conditions and dimensions on site and report any discrepancies between drawings and site conditions to the Architect prior to construction.
2. Noted dimensions take precedence over scaled dimensions. 3. If this drawing is copied or not printed at full size, verify drawing scale
before scaling dimensions. 4. Site dimensions are approximate (refer to survey as necessary.) 5. Read drawings in conjunction with Architectural Notes, Specifications
and Site Instructions, and drawings and specifications of other disciplines, including Structural, Electrical, Mechanical, Plumbing, Civil and Interior Design. Report discrepancies or conflicts to the Architect.
6. Where conflicts arise between notes, specifications, drawings, manufacturers’ instructions, general trade practices and statutory requirements, the more stringent shall apply. In cases where the conflict impacts the cost or any visible aspect of the work, advise the Architect.
7. All proposed substitutions and deviations from drawings, notes and specifications shall be submitted in writing to the Architect for written approval prior to construction.
8. These drawings are not record drawings nor as-built drawings and may not be relied on for any purposes other than the current project.
Standards
1. All work shall conform to statutory requirements, including applicable Building, Electrical, Plumbing, Gas and Fire Codes, local Codes and Bylaws, Building Inspector requests, and Safety and Health Standards.
2. All work requiring the involvement of a professional engineer is to be carried out under the authority of an appropriate registered engineer.
3. Installation of all materials, equipment, fixtures and systems shall be done in accordance with Manufacturers’ instructions.
4. Where construction or installation requires additional elements not specifically shown in these drawing, such elements shall be deemed to be included and shall be provided. The General Contractor shall coordinate installation of blocking and/or backing required for supporting wall or ceiling fixtures, handrails, furniture, equipment, and accessories as needed, whether or not these are shown on the drawings.
Radiant City Architecture Inc.
#222-1118 Homer St. Vancouver BC V6B 6L5Tel: 604-551-9376 [email protected]
As indicated
COPYRIGHT NOTICEThese drawing is an instrument of service and remains the property of the Architect. It is not to be used or reproduced for any purpose other than construction of the current project without the explicit written consent of the Architect.
Project Number
Date Plotted
Drawn By
Checked By RJB
20
18
11
28
1/2/
2020
5:2
3:47
PM
Z:\
185
6 -
Ca
mbi
e S
t Day
care
\Rev
it\1 8
56
- C
ambi
e S
t Day
care
.rvt
1/2/2020 5:23:47 PM
1/2/20205:23:47 PM
AC-4.0Site and Parking Level Plans
1856
JC
3353 Cambie St.Vancouver BC
Cambie St. Daycare
No. Description Date1 Concept Review 2019-03-012 Social Planning Review 2019-04-053 Rezoning Preliminary Enquiry 2019-06-114 Rezoning Enquiry 2019-07-125 Rezoning Enquiry Meeting 2019-12-046 Consultant Review 2020-01-02
1/64" = 1'-0"
Site Plan1
1/32" = 1'-0"
Parking 12
1/32" = 1'-0"
Parking 23
1/32" = 1'-0"
Parking 34
Pro
pert
y lin
e
Pro
pert
y lin
e
4
AC-5.0
3
AC-5.0
6 Class Bbicycles
DN1 in 222% DN
DN10%
Bui
ldin
g lin
e
0.00'
Stair 1
Stair 2
6 Class Bbicycles
RETAIL
Temporarystorage area
Lobby
Property line
Property line
13% 10%
127' - 10"2' - 0"
66' -
0"
45' - 5"20' - 0" 12' - 4" 52' - 1"
2' - 0"10' - 0"
141' - 10"
12 stroller spaces
DN
Pro
pert
y lin
e
4
AC-5.0
3
AC-5.0
Stair 1
Daycare8 infants, 8 toddlers and 8 preschoolers
OutdoorCoveredoutdoor
Property line
Property line
Bui
ldin
g lin
e
Pro
pert
y lin
e
66' -
0"
10' - 0"
141' - 10"2' - 0"
2' - 0" 55' - 10" 72' - 0"
Stair 2
Bui
ldin
g lin
e
Pro
pert
y lin
e
Pro
pert
y lin
e
4
AC-5.0
3
AC-5.0
Stair 1
Property line
Property line
Office
66' -
0"
10' - 0"
141' - 10"2' - 0"
68' - 0"
Stair 2
4' - 0"57' - 10"
Bui
ldin
g lin
e
4
AC-5.0
Pro
pert
y lin
e
Pro
pert
y lin
e
3
AC-5.0
Stair 1
Property line
Property line66
' - 0
"
10' - 0"
Office
141' - 10"2' - 0"
68' - 0"61' - 10"
Stair 2
Scale
Drawing Notes
1. This drawing reflects the intent of the design. Verify existing conditions and dimensions on site and report any discrepancies between drawings and site conditions to the Architect prior to construction.
2. Noted dimensions take precedence over scaled dimensions. 3. If this drawing is copied or not printed at full size, verify drawing scale
before scaling dimensions. 4. Site dimensions are approximate (refer to survey as necessary.) 5. Read drawings in conjunction with Architectural Notes, Specifications
and Site Instructions, and drawings and specifications of other disciplines, including Structural, Electrical, Mechanical, Plumbing, Civil and Interior Design. Report discrepancies or conflicts to the Architect.
6. Where conflicts arise between notes, specifications, drawings, manufacturers’ instructions, general trade practices and statutory requirements, the more stringent shall apply. In cases where the conflict impacts the cost or any visible aspect of the work, advise the Architect.
7. All proposed substitutions and deviations from drawings, notes and specifications shall be submitted in writing to the Architect for written approval prior to construction.
8. These drawings are not record drawings nor as-built drawings and may not be relied on for any purposes other than the current project.
Standards
1. All work shall conform to statutory requirements, including applicable Building, Electrical, Plumbing, Gas and Fire Codes, local Codes and Bylaws, Building Inspector requests, and Safety and Health Standards.
2. All work requiring the involvement of a professional engineer is to be carried out under the authority of an appropriate registered engineer.
3. Installation of all materials, equipment, fixtures and systems shall be done in accordance with Manufacturers’ instructions.
4. Where construction or installation requires additional elements not specifically shown in these drawing, such elements shall be deemed to be included and shall be provided. The General Contractor shall coordinate installation of blocking and/or backing required for supporting wall or ceiling fixtures, handrails, furniture, equipment, and accessories as needed, whether or not these are shown on the drawings.
Radiant City Architecture Inc.
#222-1118 Homer St. Vancouver BC V6B 6L5Tel: 604-551-9376 [email protected]
As indicated
COPYRIGHT NOTICEThese drawing is an instrument of service and remains the property of the Architect. It is not to be used or reproduced for any purpose other than construction of the current project without the explicit written consent of the Architect.
Project Number
Date Plotted
Drawn By
Checked By RJB
20
18
11
28
1/2/
2020
5:2
3:48
PM
Z:\
185
6 -
Ca
mbi
e S
t Day
care
\Rev
it\1 8
56
- C
ambi
e S
t Day
care
.rvt
1/2/2020 5:23:48 PM
1/2/20205:23:48 PM
AC-4.1Floor Plans
1856
JC
3353 Cambie St.Vancouver BC
Cambie St. Daycare
No. Description Date1 Concept Review 2019-03-012 Social Planning Review 2019-04-053 Rezoning Preliminary Enquiry 2019-06-114 Rezoning Enquiry 2019-07-125 Rezoning Enquiry Meeting 2019-12-046 Consultant Review 2020-01-02
1/32" = 1'-0"
First Floor on Cambie St.1
1/32" = 1'-0"
Second Floor2
1/32" = 1'-0"
Third Floor3
1/32" = 1'-0"
Fourth Floor4