jce company profile
DESCRIPTION
Uploaded from Google DocsTRANSCRIPT
JC Electrofields Power System, Inc. was conceived in response to the
need for responsible implementation of electrical systems . A company with diversified interests and resources committed to ensure the provision of current and future electrical needs of its customers through reliable products and services with superior
quality and performance.
JCE is an Electrical Contractor specializing in electrical systems including design, construction and completion. Conceived in 1997, it has invested years of excellent service and commitment to total customer satisfaction.
The group is composed of technical personnel armed with knowledge, special ski lls
and expertise with related experience of engineering practice in their own fields.
OUR MISSION AND COMMITMENT • To identify and to serve the needs of every customer in the most responsible manner with safety as the main consideration
• Strive for customers’ satisfaction through excellence in re liable service and superior quality of materials • Enhance customer’s awareness of our commitment to serve their needs and
the benefits that they’ll gain out of our quality products and services • Strengthen our commitment to responsibly attend to our customer’s needs by
constantly updating our personnel skills and expertise to modern technology through exposure to training and development programs.
PRODUCT RANGE AND SERVICES • Plant Electrical Design and Construction. • Plant Electrical Maintenance.
• Electrical Consulting/Billing, Upgrading, Optimization. • Specialists in Control Wiring and Motor Controls. • PLC Design, Programming and Installation.
• Automation and Controls. • Transmission Lines Design and Construction up to 138 KV.
• Transformer Rewinding, Conversion, and Servicing up to 50MVA. • Specialist in Direct Connection Application for NPC/PSALM via NGCP 69 KV lines
through ERC..
• Specialist in Power Sub-Station Design and Construction up to 138 KV. • Design , Fabrication, and Assembly of LVSG,MVSG up to 34.5 KV.
• Sub-Station Maintenance and Servicing. • Other related products and services.
GOVERNMENT LICENSES & ACCREDITATION:
PARTIAL LIST OF PROJECTS UNDERTAKEN
Subcontracted under Foreign Contractor, “Hyosung
Corporation” for the Luzon Substation Expansion Project 1 (SP09.LSEP1.Lt.0028)
of NATIONAL GRID CORPORATION OF THE PHILIPPINES
in particular LAOAG, BANTAY, BAUANG, CRUZ-NA-DAAN, & CABANATUAN
SUBSTATIONS
Substation Works Include: 1. LAOAG SUBSTATION 1.1 Installation Works of; a. 50MVA, 115/69-13.8kV, 3Φ, 60Hz Auto-Transformer – 1set b. 115kV Capacitive Voltage Transformer – 3 units
c. 96kV Surge Arrester – 3 units d. 69kV, 1200A, 25kA SF6 Power Circuit Breaker – 3 units e. 69kV, 1200A, 25kA Disconnect Switch – 3 units
f. 69kV, 1200A:5 Multi Ratio Current Transformer – 3 units g. 69kV Inductive Voltage Transformer – 6 units h. 115kV & 69kV Tower with Complete Electrical Hardware’s – 1 lot
i. Grounding Materials – 1 lot j. Power, Control and Instrumentation Cables – 1 lot k. Transformer, CVT, DS & Protection Panel – 1 lot
1. 2 Test & Commissioning Works of; a. Power Transformer a.1 Insulation Resistance Test a.2 Power Factor Test on each Winding
a.3 Power Factor Test on all Bushings a.4 Moisture content and Dielectric Strength of Oil b. Circuit Breaker
b.1 Insulation Resistance Test b.2 Test of Breaker Timing b.3 Test on secondary wiring insulation
b.4 Tests of Gas leakage and dew point (SF6-Type) b.5 Tests of SF6 purity b.6 Checking of SF6 Pressure
b.7 Operation Test c. Disconnect Switches c.1 Testing of Insulation Resistance
c.2 Measurements of contact resistance c.3 Checking of Operating Mechanism c.4 Anti condensation (Heater) function
d. Current Transformer d.1 Polarity Test d.2 Ratio Test
d.3 Excitation Test d.4 Winding Resistance d.5 Insulation Resistance Test
d.6 Burden Measurement d.7 Insulation Power Factor e. Voltage Transformers
e.1 Ratio Test e.2 Excitation Test e.3 Winding Resistance
e.4 Insulation Test e.5 Burden Measurement e.6 Insulation Power Factor
2. BANTAY SUBSTATION
2.1 Installation Works of; a. 50MVA, 115/69-13.8kV, 3Φ, 60Hz Auto-Transformer – 1set b. 115kV Capacitive Voltage Transformer – 3 units c. 96kV Surge Arrester – 3 units d. 69kV, 1200A, 25kA SF6 Power Circuit Breaker – 3 units e. 69kV, 1200A, 25kA Disconnect Switch – 3 units f. 69kV, 1200A:5 Multi Ratio Current Transformer – 6 units g. 69kV Inductive Voltage Transformer – 6 units h. 15kV Metal Clad Switchgear – 1 set i. 115kV & 69kV Tower with Complete Electrical Hardware’s – 1 lot j. Grounding Materials – 1 lot k. Power, Control and Instrumentation Cables – 1 lot l. Transformer, CVT, DS & Protection Panel – 1 lot 2.2 Test & Commissioning Works of; a. Power Transformer a.1 Insulation Resistance Test a.2 Power Factor Test on each Winding a.3 Power Factor Test on all Bushings a.4 Moisture content and Dielectric Strength of Oil b. Circuit Breaker b.1 Insulation Resistance Test b.2 Test of Breaker Timing b.3 Test on secondary wiring insulation b.4 Tests of Gas leakage and dew point (SF6-Type) b.5 Tests of SF6 purity b.6 Checking of SF6 Pressure b.7 Operation Test c. Disconnect Switches c.1 Testing of Insulation Resistance c.2 Measurements of contact resistance c.3 Checking of Operating Mechanism c.4 Anti condensation (Heater) function d. Current Transformer d.1 Polarity Test d.2 Ratio Test d.3 Excitation Test d.4 Winding Resistance d.5 Insulation Resistance Test d.6 Burden Measurement d.7 Insulation Power Factor e. Voltage Transformers e.1 Ratio Test e.2 Excitation Test e.3 Winding Resistance e.4 Insulation Test e.5 Burden Measurement e.6 Insulation Power Factor
3. BAUANG SUBSTATION 3.1 Installation Works of; a. 100MVA, 230/69-13.8kV, 3Φ, 60Hz Auto-Transformer – 1set b. 230kV, 2000A, 40kA SF6 Power Circuit Breaker – 3 units
c. 230kV Capacitive Voltage Transformer – 3 units d. 230kV, 2000A:5 Multi Ratio Current Transformer – 6 units e. 230kV, 2000A, 44kA Disconnect Switch – 6 units f. 192kV Surge Arrester – 3 units g. 72.5kV, 1200A, 25kA Disconnect Switch – 6 units h. 72.5kV, 2000A, 25kA SF6 Power Circuit Breaker – 1 set i. 72.5kV, 1200A:5 Multi Ratio Current Transformer – 3 units j. 230kV & 69kV Steel Tower Structures – 1 Gantry k. 230kV & 69kV Complete Electrical Hardware’s – 1 lot l. Grounding Materials – 1 lot m Power, Control and Instrumentation Cables – 1 lot n. 15kV Metal Clad Switchgear – 1 set o. Transformer, CVT, DS & Protection Panel – 1 lot 3.2 Test & Commissioning Works of; a. Power Transformer a.1 Insulation Resistance Test a.2 Power Factor Test on each Winding a.3 Power Factor Test on all Bushings a.4 Moisture content and Dielectric Strength of Oil b. Circuit Breaker b.1 Insulation Resistance Test b.2 Test of Breaker Timing b.3 Test on secondary wiring insulation b.4 Tests of Gas leakage and dew point (SF6-Type) b.5 Tests of SF6 purity b.6 Checking of SF6 Pressure b.7 Operation Test c. Disconnect Switches c.1 Testing of Insulation Resistance c.2 Measurements of contact resistance c.3 Checking of Operating Mechanism c.4 Anti condensation (Heater) function d. Current Transformer d.1 Polarity Test d.2 Ratio Test d.3 Excitation Test d.4 Winding Resistance d.5 Insulation Resistance Test d.6 Burden Measurement d.7 Insulation Power Factor e. Voltage Transformers e.1 Ratio Test e.2 Excitation Test e.3 Winding Resistance e.4 Insulation Test e.5 Burden Measurement e.6 Insulation Power Factor
4. CRUZ-NA-DAAN SUBSTATION 4.1 Installation Works of; a. 100MVA, 230/69-13.8kV, 3Φ, 60Hz Auto-Transformer – 1set b. 230kV, 2000A, 44kA Disconnect Switch – 3 units
c. 230kV Capacitive Voltage Transformer – 3 units d. 192kV Surge Arrester – 3 units e. 72.5kV, 2000A, 25kA SF6 Power Circuit Breaker – 1 set f. 72.5kV, 1200A, 25kA Disconnect Switch – 6 units g. 72.5kV, 1200A:5 Multi Ratio Current Transformer – 3 units h. 72.5kV Inductive Voltage Transformer – 3 units i. 230kV & 69kV Steel Tower Structures – 1 Gantry j. 230kV & 69kV Complete Electrical Hardware’s – 1 lot k. Grounding Materials – 1 lot l. Power, Control and Instrumentation Cables – 1 lot m.15kV Metal Clad Switchgear – 1 set n. 460V Switchboard – 1 set o. Transformer, CVT, DS & Protection Panel – 1 lot 4.2 Test & Commissioning Works of; a. Power Transformer a.1 Insulation Resistance Test a.2 Power Factor Test on each Winding a.3 Power Factor Test on all Bushings a.4 Moisture content and Dielectric Strength of Oil b. Circuit Breaker b.1 Insulation Resistance Test b.2 Test of Breaker Timing b.3 Test on secondary wiring insulation b.4 Tests of Gas leakage and dew point (SF6-Type) b.5 Tests of SF6 purity b.6 Checking of SF6 Pressure b.7 Operation Test c. Disconnect Switches c.1 Testing of Insulation Resistance c.2 Measurements of contact resistance c.3 Checking of Operating Mechanism c.4 Anti condensation (Heater) function d. Current Transformer d.1 Polarity Test d.2 Ratio Test d.3 Excitation Test d.4 Winding Resistance d.5 Insulation Resistance Test d.6 Burden Measurement d.7 Insulation Power Factor e. Voltage Transformers e.1 Ratio Test e.2 Excitation Test e.3 Winding Resistance e.4 Insulation Test e.5 Burden Measurement e.6 Insulation Power Factor
5. CABANATUAN SUBSTATION
5.1 Installation Works of; a. 300MVA, 230/69-13.8kV, 3Φ, 60Hz Auto-Transformer – 1set b. 230kV Capacitive Voltage Transformer – 3 units c. 192kV Surge Arrester – 3 units d. 230kV & 69kV Bus Works – 2 Gantry e. 230kV & 69kV Complete Electrical Hardware’s – 1 lot f. Grounding Materials – 1 lot g. Power, Control and Instrumentation Cables – 1 lot h. Fire Protection System of 300MVA Transformer 5.2 Test & Commissioning Works of; a. Power Transformer a.1 Insulation Resistance Test a.2 Power Factor Test on each Winding a.3 Power Factor Test on all Bushings a.4 Moisture content and Dielectric Strength of Oil b. Voltage Transformers b.1 Ratio Test b.2 Excitation Test b.3 Winding Resistance b.4 Insulation Test b.5 Burden Measurement b.6 Insulation Power Factor
Subcontracted under Foreign Contractor, “Hyosung
Corporation” for the Luzon Substation Expansion Project 2 (SP11.LSEP2.Lt.0067)
of NATIONAL GRID CORPORATION OF THE PHILIPPINES
in particular SANTIAGO SUBSTATION
1. SANTIAGO SUBSTATION
5.1 Installation Works of; a. 230kV, 2000A, 40kA SF6 Power Circuit Breaker – 3 units b. 230kV, 2000A, 44kA Disconnect Switch – 6 units c. 230kV, 2000A:5 Multi Ratio Current Transformer – 6 units d. 192kV Surge Arrester – 3 units e. 230kV & 69kV Bus Works – 2 Gantry f. 230kV & 69kV Complete Electrical Hardware’s – 1 lot g. Grounding Materials – 1 lot h. Power, Control and Instrumentation Cables – 1 lot 5.2 Test & Commissioning Works of; a. Circuit Breaker b.1 Insulation Resistance Test b.2 Test of Breaker Timing b.3 Test on secondary wiring insulation b.4 Tests of Gas leakage and dew point (SF6-Type) b.5 Tests of SF6 purity b.6 Checking of SF6 Pressure b.7 Operation Test b. Disconnect Switches c.1 Testing of Insulation Resistance c.2 Measurements of contact resistance c.3 Checking of Operating Mechanism c.4 Anti condensation (Heater) function
JCE PROJECTS UNDERTAKEN: 1. Elegant Chemical Alloy Corp.
Address: Villanueva Phivedoc. Misamis Oriental
Scope of Work: (A) Design & Construction of 50 MVA Substation 138
KV/69KV/3.3KV including repair and supply of 69 KV OCB
& Switchgear
(B) Design and Construction of Smelting Plant Electrical
Systems
Contact Person: Mr. Tony Tiu, Owner / 088-5670180
2. Zamcelco ( Sub-contracted under Lin Man Power )
Address: Zamboanga City
Scope of Work: (A) Design & Construction of 41 MVA Substation 69 KV/13.2KV
(B) Construction of 69 KV Transmission Lines, 5kms
(C) Construction of 20MVA Substation, Assembly of Gas
Insulated Switchgear 13.2kV
3. Melters Steel Corp. Address: San Simon, Pampanga
Scope of Work: (A) Design & Construction of 35 MVA Substation 69 KV/34.5KV
(B) Design & Construction of 31 MVA Substation 69 KV/34.5KV
(C) Processing of ERC Approval for 69kV Direct Connection.
(D) Design & Construction of 69kV Transmission & 34.5kV
Distribution Lines.
Contact Person: Mr. Ricardo Lim / 09175217070
4. NorthStar Mall Address: Ilagan, Isabela
Scope of Work: A.) Design & Construction of 10MVA, 69kV/13.2kV Sub-Station
B.) Design & Construction of 3x1.5MVA, 13.2kV-230/380V Sub-Station
C.) Design & Construction of 69kV Transmission Lines, 800m
D.) Construction of 13.2 kV Switchgear
E.) Processing of ERC Approval for 69kV Direct Connection.
Contact Person: Ms. Janet Tan, President
5. RJS Commodities Inc.
Address: Talavera, Nueva Ecija
Scope of Work: (A) Design & Construction of 5 MVA Substation 69 KV/13.2 KV
(B) Design & Construction of 3kms. 69 KV Transmission Lines
(C) Processing of ERC Approval for 69kV Direct Connection.
(D) Supply & Installation of 3 - 3x100 kVAR Capacitor Bank
Contact Person: Mr. Ramon Syson
6. NEECO 1
Address: Nueva Ecija
Scope of Work: (A) Design & Construction of 69kV Gantry & Tower Structures.
(B) Sub Contracted under Pazifik Power Inc. for assembly of
20MVA, 69kV/13.2kV Substation Equipment & Switchgear.
Contact Person:
7. Northwest Steel (Sub-contracted under New San Jose Builders, Inc.)
Address: Pulilan, Bulacan
Scope of Work: (A) Consultancy & Supervision for the Rehabilitation of the
whole Rolling Mill Plant Automation & Control System
(B) Supply & Construction of 7.5MVA, 69kV/2.4kV Substation
Contact Person: Engr. Nicholas Borgonia, Project Manager
8. Builders Steel Corp.
Address: Lawang Bato, Valenzuela City
Scope of Work: (A) Servicing of 6 MVA Substation, 34.5kV/2.4kV
Contact Person: Ms. Barbara Tiu, Owner / 02 4454170-75
9. Continental Steel Mfg. Corp. Address: Bo. Lingunan, Valenzuela City
Scope of Work: (A) Servicing of 6 MVA Substation, 34.5kV/2.4kV
(B) Consultancy & Supervision for the Rehabilitation of the
whole Rolling Mill Plant Automation & Control System
(C) Upgrading of Mill Motor Control System
Contact Person: Mr. Andrew King, Manager / 02-2928585 or 02-2932029
10. Quanta Paper Corp.
Address: Mabalacat, Pampanga
Scope of Work: (A) Design & Construction of 6 MVA, 69kV/13.2kV Substation
(B) Design & Construction of 69kV Incoming Transmission Line
(C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
11. Falcon Metal Corp. Address: San Bartolome, Quezon City
Scope of Work: (A) Servicing of 5 MVA Substation, 34.5kV/2.4kV
(B) Construction of 1 MVA Substation
Contact Person: Mr. Eddie Go, Owner / 02-9394411 or 02-9390502
12. Centerra Ice Plant
Address: San Simon, Pampanga
Scope of Work: (A) Design & Construction of 4 MVA, 69kV/480V Substation
(B) Design & Construction of 69kV Incoming Transmission Line
(C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
13. Real Steel Corp. Address: San Simon, Pampanga
Scope of Work: (A) Design & Construction of 10 MVA, 69kV/13.2kV Substation
(B) Design & Construction of 69kV Incoming Transmission Line (C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
Contact Person:
14. MJBJ Hatchery
Address: Diffun, Quirino Province
Scope of Work: (A) Design & Construction of 3.75 MVA, 69kV/13.2kV Substation
(B) Design & Construction of 69kV Incoming Transmission Line (C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
15. Bicol La Suerte Copra Mill
Address: Labo, Camarines Norte
Scope of Work: (A) Design & Construction of 1.5 MVA, 69kV/460V Substation
(B) Design & Construction of 69kV Incoming Transmission Line (C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
16. DMCI-Palawan Plant
Address: Irawan, Puerto Princesa City, Palawan
Scope of Work: (A) Supply, Installation, and Testing Commissioning of 5.0 MVA,
460V/13.2kV Substation.
(B) Supply, Installation and Testing Commissioning of 69kV
Switchyard Equipment (CT, VT, PCB-SF6, DS, LA in
particulars).
(C) Design and Fabrication of 69kV Steel Structures.
17. Altima Empire Steel Corp.
Address: San Simon, Pampanga
Scope of Work: (A) Design & Construction of 12.5 MVA, 69kV/13.2kV Substation
(B) Design & Construction of 69kV Incoming Transmission Line (C) Processing of ERC & NGCP approval for 69kV Direct
Connection. Contact Person:
18. Universal Steel Smelting Co. Inc.
Address: Balintawak, Quezon City
Scope of Work: (A) Servicing of 5 MVA Substation
(B) Design, Assembly, Installation of Plant Electrical and
Automation Systems
Contact Person: Engr. Edwin Chao,Plant Mgr. /02-3610919or02-3637081 to 82
19. Zest-O Corp. (Subcontracted under Double Share Ent. )
Address: Canlubang, Laguna
Scope of Work: (A) Supply & Construction of 3 MVA & 1 MVA Substation
Contact Person: Mr. Celso Sebastian, Owner / 0917-3210523
20. Albay Trading & Rice Mill
Address: Pili, Albay
Scope of Work: (A) Design & Construction of 3 MVA, 69kV/13.2kV Substation
(B) Design & Construction of 69kV Incoming Transmission Line
(C) Processing of ERC & NGCP approval for 69kV Direct
Connection.
Contact Person:
21. Grande Steel Corporation
Address: Dampol 2ndB, Pulilan, Bulacan
Scope of Work: A.) Design & Construction of 2.5 MVA Substation, 13.2kV/3.3kV
B.) Construction of 13.2kV Distribution Line
Contact Person:
22. Kabayan Ice Plant and Cold Storage
Address: Candelaria, Zambales
Scope of Work: (A) Design & Construction of 2 MVA Substation 69 KV/460V
(B) Construction of 69 KV Transmission Lines
(C) Processing of ERC approval
Contact Person: Mrs. Jing Santos, Owner / 047-2377317
23. HCH Wood Corporation Address: Tagoloan, Phividec, Misamis Oriental
Scope of Work: (A) Design, Construction & Installation of 2MVA, 69kV/240V
Substation
(B) Supply of 69 KV OCB & Switchgear
Contact Person: Ms. Jenifer Sabenacio, AGM / (08822)74-2881
24. Philippine Recyclers Inc.
Address: Marilao, Bulacan
Scope of Work: (A) Rewinding/Remanufacturing of 2 MVA Transformer &
Construction of Substation
Contact Person: Engr. Conrad Mendoza, Manager / 044-7112262
25. Solid Jade Corp. Address: Bo. Bagbag, Quezon City
Scope of Work: (A) Design & Construction of 1 MVA Substation, 34.5kV/460V
Contact Person: Benjie / 09186369970
26. Purity Ice Plant and Cold Storage
Address: Labo, Camarines Norte
Scope of Work: (A) Supply & Construction of 1 MVA Substation 69kV-277/480V
Contact Person: Mr. Jaime Rabo, Owner / 02-247095
27. Unicorn Metal Corp.
Address: Punturin, Valenzuela City
Scope of Work: (A) Design & Installation of 1.6 MVA Substation 34.5kV/2.4kV
Contact Person: Mr. Edward Chua, Owner / 02-4329002
28. Southside Homeowners Association Inc. Address: Jusmag, Fort Bonifcaio, Taguig City
Scope of Work: (A) Supply & Construction of 1 MVA Substation 34.5kV/240V
Contact Person: Mrs. Virginia Santos, President / 0917-8573352
29. Farmers Milling & Supply Inc. Address: Panit-an Capiz
Scope of Work: (A) Rewinging, Remanufacturing and Supply of 1 MVA
Transformer & Supply of Accessories
Contact Person: Mr. Thomas Moskal, Owner / 036-6340793
30. Top Lite Corporation
Address: Lawang Bato, Valenzuela City
Scope of Work: (A) Turn key Project for the Design, Construction, Commissioning,
Operational turnover of Rolling / Bar Mill Plant.
31. 21st
Century Steel
Address: Bo. San Juan, Taytay, Rizal
Scope of Work: (A) Supervision & Consultancy for the Rehabilitation of Mill
Motors, DC Control System
(B) Rehab & Repair of 34.5 KV Distribution Systems
32. Dragon Asia Rolling Mill Address: Valenzuela City
Scope of Work: (A) Design, Assembly, Commissioning of Plant Electrical and
Automation Systems
Contact Person: Mr. Tony L. Co, Owner / 029831758-60
33. Grand Asia Metal Corp.
Address: Bagbaguin, Valenzuela City
Scope of Work: (A) Design, Assembly, Supply, Installation & Commissioning of
Plant Automation Systems
Contact Person: Mr. Julian Pua, VP / 02-9377920
34. Coto Mines
Address: Masinloc, Zambales
Scope of Work: (A) Rehabilitation of 69 KV Transmission Lines
(B) Design & Assembly of Generator Synchronizing Panel
35. White Rock Hotel
Address: Subic, Zambales
Scope of Work: (A) Design & Construction of 13.2 Distribution Feeders
(B) Design & Construction of Wavepool Machineries and
Automation
Contact Person: Mr. George Lorenzana, President
36. Malamig Park Resort Address: Bustos, Bulacan
Scope of Work: (A) Design & Construction of 13.2 Distribution Lines
(B) Installation of 3x100kVA Transformer Bank
(C) Design & Construction of Wavepool Machineries and
Automation
Contact Person: Mr. Paterno Buensuceso, Manager
37. GALILEE GARDEN RESORT
Address: Bustos, Bulacan
Scope of Work: (A) Design & Construction of 13.2 Distribution Lines
(B) Supply & Installation of 3x50kVA Transformer Bank
(C) Supply & Installation of 2x75kVA, 1x100kVA, & 1x167kVA Transformer
(D) Design & Construction of Wavepool Machineries and Automation
38. MKK Steel Corp.
Address: Bo. Lingunan, Valenzuela City
Scope of Work: (A) Supply and Installation of Capacitor Banks, 34.5 KV
Contact Person: Engr. Danny Anonuevo, Manager / 02-2928042
39. Legacy Steel Corp.
Address: Pasig City
Scope of Work: (A) Supply & Installation of Capacitor Banks, 34.5 KV
40. MBP Star Corp.
Address: Valenzuela City
Scope of Work: (A) Supply & Construction of First Private Pole, 34.5 KV
Contact Person: Mr. Ax gaw, Manager / 02-4454107
41. Lunar Steel Corp.
Address: Pasig City
Scope of Work: (A) Emergency Repair of Rolling Mill Motor Control & Switchgear
42. Midland Steel Corp. Address: Cainta, Rizal
Scope of Work: Testing & Servicing of 750kVA Transformer
43. CDO Foodsphere, Inc. Address: Paso De Blas, Valenzuela City
Scope of Work: A.) Rehabilitation of Electrical System
B.) Supply & Installation of Nema 4X Panel (2000A), 200kVA &
2x100kVA Transformer (Dry Type)
Contact Person:Mr. Jerico Tugade
44. CDO Foodsphere, Inc.
Address: Malvar, Batangas
Scope of Work: A.) Servicing of 10MVA, 69kV/13.2kV Substation
B.) Servicing of 3 x 2MVA & 2 x 1MVA Distribution Transformer
C.) Supply & Installation of 3- 6x100 kVAR Capacitor Bank
Contact Person:
45. La Suerte Rice Mill Address: Aurora, Isabela
Scope of Work: A.) Assembly & Installation of Generator Synchronizing Panel
B.) Repair/Rewinding of 1100kW, 480V AC Generator
Contact Person:
46. Family Choice/Golden Season Grains Center
Address: Cabatuan, Isabela / Luna, Isabela
Scope of Work: A.) 13.2kV Black Start Generator Synchronizing Panel
B.) 4000A Low Voltage Switchgear Wiring and Assembly
Contact Person: Mr. Leoncio M. Tan,President
47. Oliver Rice Mill Address: Talavera, Nueva Ecija
Scope of Work: A.) Design and Construction of 13.2 KV Distribution Line, 2.5km
B.) Supply & Installation of 1500kVA, 13.2kV/460V Transformer
Contact Person:
48. Math Breeder Corp.
Address: Balagtas, Bulacan
Scope of Work: (A) Design and Construction of 13.2 KV Distribution Systems
Contact Person: Mr. Miguelito Hizon
49. Philippine Recyclers Inc.
Address: Marilao, Bulacan
Scope of Work: (A) Installation of Main Feeder Lines for Scrubber Plant
50. Corfarm Piggery, Inc.
Address: Pandi, Bulacan
Scope of Work: A.) Construction of 13.2kV Distribution Line
B.) Supply & Installation of 3x100kVA, 13.2kV/230V Transformer
Bank
Contact Person: Mr. Miguelito Hizon, President
51. Maxima Agro. Corp.
Address: Pandi, Bulacan
Scope of Work: A.) Construction of 13.2kV Distribution Line
B.) Supply & Installation of 6x75kVA, 13.2kV/240kV Transformer
Bank.
C.) Supply & Installation of 3x167kVA, 13.2kV/240kV
Transformer Bank.
Contact Person: Mr. Miguelito Hizon, President
52. Everest Plastic Containers Industry, Inc.
Address: Meycuayan, Bulacan
Scope of Work: A.) Upgrading of 3-3x333kVA, 34.5kV/240V Transformer Bank
B.) Construction of First Private Pole, 34.5kV Dist. Line
Contact Person: Mr. Lito Tan, President
53. REMS Synthetic Inc.
Address: Meycauayan Bulacan
Scope of Work: (A) Design & Construction of 2-3x333kVA, 34.5kV/240V
Transformer Bank
Contact Person: Mr. Benito Sy / 09175326016
54. Flexible Packaging Product Corp.
Address: Lawang Bato, Valenzuela City
Scope of Work: A.) Upgrading of 4x1.5MVA,34.5kV/240V Power Transformer
B.) Construction of First Private Pole, 34.5kV Dist. Line
Contact Person:
55. Calypso Plastic Corp.
Address: Mapulang Lupa, Valenzuela City
Scope of Work: A.) Upgrading of 5x1.5MVA,34.5kV/240V Power Transformer
B.) Construction of First Private Pole, 34.5kV Dist. Line
Contact Person:
56. Tubo Star Steel MFG. Corp.
Address: Lawang Bato, Valenzuela City
Scope of Work: A.) Supply & Installation of 3x167kVA, 34.5kV/240V Transformer
Bank
B.) Construction of First Private Pole, 34.5kV
Contact Person: Engr. Robert Nery, Superintendent
57. Styrotech Corporation Address: Meycuayan Bulacan
Scope of Work: A.) Supply & Installation of 3-3x333kVA, 34.5kV/240V
Transformer Bank
B.) Construction of First Private Pole &34.5kV Distribution
System
Contact Person:
58. Gilvan Packaging Corporation
Address: Paso De Blas, Valenzuela City
Scope of Work: A.) Supply & Installation of 2-3x333kVA, 34.5kV/240V
Transformer Bank
B.) Construction of First Private Pole, 34.5kV
Contact Person: Mr. Jun Yao
59. Aztec Construction
Address: Cogeo, Rizal
Scope of Work: A.) Supply & Installation of 3x333kVA, 34.5kV/240V Transformer
Bank
B.) Construction of 34.5kV Distribution Line & First Private Pole
Contact Person: Mr. Kenneth Cham, President
60. JR Plastic Address: San Pedro, Laguna
Scope of Work: A.) Supply & Installation of 3-3x333kVA, 34.5kV/240V
Transformer Bank
B.) Construction of 34.5kV Distribution Line & First Private Pole
Contact Person:
61. Plastic Plus Manufacturing Inc.
Address: Cavite Economic Zone, Rosario, Cavite
Scope of Work: A.) Supply & Installation of 1-3x333kVA, 34.5kV/240V
Transformer Bank
B.) Construction of 34.5kV First Private Pole
Contact Person:
62. Haitima Clark Corporation
Address: Clark Economic Zone, Clark, Pampanga
Scope of Work: A.) Recondition & Installation of 1000kVA, 13.8kV/460V and
2000kVA, 13.8kV/230kV Transformer
B.) Construction of 34.5kV First Private Pole
Contact Person:
63. Sun World Corporation
Address: Guiguinto, Bulacan
Scope of Work: A.) Installation of 2-3x333kVA, 34.5kV/240V Transformer Bank
B.) Construction of First Private Pole &34.5kV Distribution
System
C.) Design & Supply of 1600A, 240V Main Distribution Panel.
Contact Person:
64. Mega Prime Packaging Industrial Corp. Address: Sta. Maria, Bulacan
Scope of Work: A.) Installation of 3x333kVA, 34.5kV/240V Transformer Bank
B.) Construction of First Private Pole &34.5kV Distribution
System
Contact Person:
65. Rizal Poultry & Livestock Association Inc
Address: Lipa City, Batangas
Scope of Work: A.) Supply & Installation of 3x75kVA, 13.2kV/240V Transformer
Bank
B.) Construction of First Private Pole & 13.2kV Distribution
System
Contact Person:
66. Laguna Continental Tamamura Phils. Address: Sta. Rosa, Laguna
Scope of Work: A.) Supply & Installation of 3x167kVA, 34.5kV/240V Transformer
Bank
B.) Construction of First Private Pole &34.5kV Distribution
System
67. RJS Commodities Inc. Isabela Plant
Address: Ramon, Isabela
Scope of Work: (A) Supply & Construction of 1.5 MVA Substation 13.2kV/460V
(B) Design & Construction of 13.2kV Distribution Lines.
Contact Person: Mr. Ramon Syson
PARTIAL
PICTURES
OF
UNDERTAKEN
PROJECTS
NGCP - CABANATUAN SUBSTATION
300MVA, 230/69-13.8kV
ELECTRICAL WORKS
NGCP - LAOAG SUBSTATION
50MVA, 115/69-13.8kV
ELECTRICAL WORKS
NGCP - BANTAY SUBSTATION
50MVA, 115/69-13.8kV
ELECTRICAL WORKS
NGCP - BAUANG SUBSTATION
100MVA, 230/69-13.8kV
ELECTRICAL WORKS
NGCP – CRUZ NA DAAN SUBSTATION
100MVA, 230/69-13.8kV
ELECTRICAL WORKS
MELTERS STEEL CORP.
35MVA, 69/34.5kV SUBSTATION
MELTERS STEEL CORP.
31.5MVA, 69/34.5kV SUBSTATION
ZAMBOANGA ELECTRIC COOPERATIVE (ZAMCELCO)
2 X 20MVA, 69/13.2kV SUBSTATION
ZAMBOANGA ELECTRIC COOPERATIVE (ZAMCELCO)
2 X 20MVA, 69/13.2kV SUBSTATION
NUEVA ECIJA ELECTRIC COOPERATIVE INC. (NEECO-1)
20MVA, 69/13.2kV SUBSTATION
NORTHSTAR MALL
10MVA, 69/13.2kV SUBSTATION
CDO BATANGAS
10MVA, 69/13.2kV SUBSTATION
QUANTA PAPER CORPORATION
7.5MVA, 69/13.2kV SUBSTATION
NORTHWEST STEEL
7.5MVA, 69/2.4kV SUBSTATION
RJS COMMODITIES
5 MVA, 69/13.2kV SUBSTATION
CENTERRA ICE PLANT
4 MVA, 69/480kV SUBSTATION
KABAYAN ICE PLANT
2 MVA, 69/480kV SUBSTATION
NORTHSTAR MALL
69kV TRANSMISSION LINE CONSTRUCTION
QUANTA PAPER CORPORATION
69kV TRANSMISSION LINE CONSTRUCTION
MELTERS STEEL CORP.
69kV TRANSMISSION LINE CONSTRUCTION
ZAMBOANGA ELECTRIC COOPERATIVE (ZAMCELCO)
69kV TRANSMISSION LINE CONSTRUCTION
CENTERRA ICE PLANT
69kV TRANSMISSION LINE CONSTRUCTION
MELTERS STEEL CORP.
6-2400kVAR, 34.5kV CAPACITOR BANK
JR PLASTIC
3 – 3X333kVA, 34.5kV/139V-277V
TRANSFORMER BANK
REMS SYNTHETIC INC.
2 – 3X333kVA, 34.5kV/139V-277V
TRANSFORMER BANK
PLASTIC PLUS MANUFACTURING INC.
3X333kVA, 34.5kV/277V-480V
TRANSFORMER BANK
CORFARM PIGGERY INC.
3X100kVA, 13.2kV/139V-277V TRANSFORMER BANK
AND 13.2kV FIRST PRIVATE POLE
MALAMIG PARK RESORT
3X100kVA, 13.2kV/139V-277V TRANSFORMER BANK
AND 13.2kV DISTRIBUTION LINE
MAXIMA AGRO CORP.
2 - 3X75kVA, 13.2kV/139V-277V TRANSFORMER BANK
AND 13.2kV FIRST PRIVATE POLE
ZAMBOANGA ELECTRIC COOPERATIVE (ZAMCELCO)
15kV GAS INSULATED SWITCHGEAR ASSEMBLY
CDO-BATANGAS PLANT
13.2kV DISTRIBUTION PANEL SERVICING
NORTHWEST STEEL CORP.
ROLLING MILL PLANT AUTOMATION
NUEVA ECIJA ELECTRIC COOPERATIVE INC. (NEECO-1)
PROTECTION & FEEDER CONTROL ASSEMBLY
NORTHSTAR MALL
13.2kV, 1250A SF6 SWITCHGEAR DESIGN & ASSEMBLY
GOLDEN SEASON GRAIN CENTER INC.
4000A, 220V LOW VOLTAGE SWITCHGEAR
DESIGN & ASSEMBLY
GOLDEN SEASON GRAIN CENTER INC.
13.2kV, 1250A VCB SWITCHGEAR DESIGN & ASSEMBLY
LA SUERTE RICE MILL
GENERATOR SYNCHRONIZING PANEL
DESIGN & ASSEMBLY
MALAMIG PARK RESORT
WAVEPOOL CONTROL PANEL
DESIGN & ASSEMBLY
TRANSFORMER CONVERSION
3.0MVA, 34.5kV/480V(Y)/277V
TO 3.0MVA, 69kV/3.3kV
LA SUERTE RICE MILL
1100kW, 480V(Y), 1650A AC GENERATOR REWINDING
MELTERS STEEL CORP.
5x37kW, 9x28kW, 2x22kW, & 3x19kW AC MOTOR REWINDING
PICTURES
OF
TESTING
INSTRUMENT
CIRCUIT BREAKER TIMER TEST SET
CBT-6P
CAPACITANCE & DISSIPATION FACTOR TEST SET
CDF-12A
TRANSFORMER OIL DIELECTRIC TESTER
RELAY TEST SET
REL-200
TRANSFORMER WINDING RESISTANCE METER
TRM-10P
AUTOMATIC TRANSFORMER RATIO TESTER
ATRT-01B
TRANSFORMER IMPEDANCE ANALYZER TEST SET
TRZ-10
RELAYING CT TEST SET
ACT-200
TRANSFORMER TURNS RATIOMETER
TTR-3000
GROUNDING TESTER
3150
HIGH VOLTAGE INSULATION TESTER
K3125
MEDIUM & LOW VOLTAGE INSULATION TESTER
MIT310
MARKER TUBE PRINTER
LM-390A
PICTURES
OF
TOOLS
AND
EQUIPMENTS
CABLE PULLER EQUIPMENT AND
CABLE UNCOILER
SHAPER & LATHE MACHINE
IRON JAW WORKER
TRANSFORMER OIL DEGASIFIER
HYDRAULIC CRIMPER
ELECTRICAL BUCKET TRUCK
BOOM TRUCK
5-Tonner TRUCK CRANE
POWER TALE GATE TRUCK
6 WHEELER FORWARD TRUCK