jcm model project of aeonmall 0717 - global...

20
JCM Model Project of AEONMALL AEONMALL ASEAN Division

Upload: others

Post on 20-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

JCM Model Project of AEONMALL

AEONMALL ASEAN Division

Page 2: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Introduce of AEONMALL

2

Page 3: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

3

AEONMALL=174 shopping malls in JAPAN & ASEANBiggest Developer in Japan

AEONMALLs in the World

JAPAN: 150 MALLASEAN: 8 MALLCHINA: 17 MALL

Page 4: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

AEONMALL in Indonesia

4

Page 5: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

ECO Project of AEON Group

5

Page 6: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

“AEON Eco Project” Announcement in 2012

50% reduction in energy usage (compared to FY2010)

200,000 kW from renewable energy sources

Make 100 Aeon stores across Japandisasterprevention facilities

6

Page 7: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

2005

▲30

▲20

▲50

▲10

FUTURE

First store opened

2010 2013

ECO Stores

・Further Energy saving & Environmental (CASBEE rank S / Energy saving ▲50% reduction)

・Disaster-preparedness local infrastructure・Traffic environment (Smart Mobility)

・Biodiversity ・Participate in Smart grid ・Smart energy network

・Optimize use of IT networks

from Eco to SmartSmart Mall development for contributing communities

EnergySaving

ratio(%)

2013Osaka dome city:40%(target)

Itami-Koya:37%

Tigusa:15%

Laketown(MORI):26%

▲40

Smart AEONShin-funabashi:30%

・Energy saving (CO2▲20% reduction)・Evaluation index(CASBEE rank A)

・Natural energy adoption

From ECO Stores to Smart AEON

7

Page 8: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Implementation of Environmental Conservation

8

Page 9: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

JCM Model Project in Indonesia[AEONMALL JGC]

9

Page 10: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Main System

Outline of the JCM Model Project at JGCSites of JCM Model Project

Panasonic Module

HIT 325w x 1560pcs

= 507kWp

ABB Inverter

50kw x 10pcs

=500kWp

Younicos ESS

100kW/111kWh

Big demand for the electricity witheconomic growth in Indonesia.

Renewable energy demand based onCOP21.

⇒ Contribution to Indonesia by

Installation of PV and Battery!!

Back Ground

Aeon Mall Jakarta Garden City in Eastern Jakarta.

Address: AEONMALL Jakarta Garden City, Kel.

Cakung Timur, Kec, Cakung, Kota, Asministrasi Jakarta

Timur

Page 11: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

GHG Mitigation Activity

The electricity from solar power system is supplied to lighting equipment.

In a daytime, surplus power is charged to storage battery, and it is used during the night.

The project achieves GHG mitigation by reducing a purchase of the electricity from the electric company.

Estimated GHG emission reduction is 549t CO2 / year.

Outline of the JCM Model Project at JGC

Page 12: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Monitoring Diagram of JGC

.

.

.

.

.

.

Solar PV String

Inverter

Energy Storage System

(Y.Cube 100kW/111kWh)

Solar PV Data Logger

(ABB VSN700-05)

Solar PV String Inverters

(ABB TRIO-50.0-TL-OUTD)

Energy storage system

Daily charge energy data

Daily discharge energy databy Converter

Daily solar PV energy generatedby Solar PV String Inverters

Solar PV System and

Energy Storage SystemMonitoring Panel

(Web access to respective remote monitoring system to obtain data)

Solar Energy Remote Monitoring

System

Energy Storage Remote Monitoring

System

Internet

Inverter

Fire command control room

Daily battery charge energy

Daily battery discharge energy

Daily solar energy generated

Irradiance, wind and temperature sensor

(ABB VBN 800-14 )

Monitoring Place: Fire Command Control Room

Monitoring Points:

A. Daily Solar PV energy generated by Solar PV Inverters

B. Daily Energy Storage System charge energy by Converter of Energy Storage System

C. Daily Energy Storage System discharge energy byConverter of Energy Storage System

Monitoring Method:

Solar Energy remote monitoring system and Energy storage remote monitoring system

Internet

Router

507 kWp Solar PV

(1560 of solar panels)

(Panasonic VBHN325SJ47)

Page 13: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Project Scheme Diagram of JGC

EPC Contract

ProcurementPV Panel PV Inverter ESS

Panasonic PanasonicABB

PanasonicYounicos

Construction

PV, Battery Installation

FFEC Subcontractor

EPC CompanyPT. Fuji Furukawa E&C Indonesia

Project Owner

PT. AEON MALL INDONESIA

Consortium Leader

ITOCHU Corporation

Consortium Agreement

Page 14: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Installed PV Panels & Storage Battery

Storage BatteryInstallation Completion

【Location: Aeon Mall Jakarta Garden city】

Cooperation with the contractor of the Mall

Confirmation of Import regulation

(Use of domestic material)

Points of Attention

PV Installation Completion

Page 15: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Project Status

2017Y

Jan Feb Mar Apr May Jun Jul Aug

Installation

Production

System Design

Cabling

ESS Installation

GEC Confirmed inspection

ESS

PV

ALL

ProductionTransport

Transport

Test running

Test running

Page 16: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Result of Monitoring form Oct 2017 to Jun 2018

16

Page 17: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

0

10000

20000

30000

40000

50000

60000

70000

Oct-17 Nov-17 Dec-17 Jan-18 Feb-18 Mar-18 Apr-18 May-18 Jun-18

Monitoring of Result(PV)

MWh

Power generation period (Oct 17 ~ Jun 18)

Quantity of the electricity generated by PV system

Average value≒51,000MWh

Page 18: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

0

500

1000

1500

2000

2500

3000

3500

4000

Oct-17 Nov-17 Dec-17 Jan-18 Feb-18 Mar-18 Apr-18 May-18 Jun-18

Monitoring of Result(Storage Battery)

Mwh

Charged and Discharged (Oct 17 ~ Jun 18)

Quantity of the electricity charged by PV systemQuantity of the electricity discharged from the project storage battery system

Page 19: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

CO2 emission reduction

CO2 emission reductions Units

264 tCO2/p

From Oct 2017 to Jun 2018

Page 20: JCM Model Project of AEONMALL 0717 - Global ...gec.jp/jcm/2018seminar_jakarta/files/3-2-2_AEONMALL.pdf0DLQ 6\VWHP 2XWOLQH RI WKH -&0 0RGHO 3URMHFW DW -*& 6LWHV RI -&00RGHO 3URMHFW

Thank you

20