jene-pc3000 & jene-pc6000dorsunautomation.com/uploads/1/0/6/3/106314743/... · jm34-160810...
TRANSCRIPT
JENE-PC3000e & JENE-PC6000e
EMBEDDED CONTROLLERSPRODUCT DATA SHEET
Page 1
OverviewThe JENE-PC3000e and JENE-PC6000e are compact, embedded devices combining integrated control, supervision, data logging, alarming, scheduling, and network management functions with Internet connectivity and web serving capabilities. As members of the JENEsys® platform, these embedded devices make it possible to control and manage equipment and external devices over the Internet and present real time information to users in web-based graphical views.
ApplicationsJENE-PC3000e and JENE-PC6000e controllers are ideal for any size facility providing distributed control and monitoring of equipment and integrated devices. Optional input/output modules can be plugged in for applications where local control is required. They support a wide range of field buses for connection to remote I/O and stand-alone controllers. In small facility applications, the JENE-PC3000e and JENE-PC6000e is all you need for a complete system.
Both the JENE-PC3000e and JENE-PC6000e serve data and rich graphical displays to a standard web browser via an Ethernet LAN or remotely utilizing the Internet or a GPRS modem. In larger facilities or for National Accounts, multi-building applications and large-scale control system integrations, JENEsys® AX Supervisor software can be used to aggregate information (real-time data, history, alarms, etc.) from large numbers of JENEs into a single, unified application. A JENEsys® AX Supervisor can manage global control functions, support data passing over multiple networks, connect to enterprise level software applications and host multiple, simultaneous client workstations connected over the local network, the Internet and dial-up or GPRS modems.
Equipment control and integration applications are generated using JENEsys® ProBuilder, a PC-based graphic engineering tool which simplifies the engineering process and assists in the start-up and trouble shooting of the application. In addition to these control applications, the JENE-PC3000e and JENE-PC6000e also perform a wide range of energy management functions including lead/lag, optimum start/stop, night purge, morning warm-up and cool-down and maximum load demand.
Features• Embedded PowerPC Platforms
• Support open and legacy protocols
• QNX Real-time Operating System
• Web User Interface serves rich and graphical browser presentations
• Run Stand-alone control, energy management, and integration applications
• Supports two optional communication cards
• Optional 16 and 34 point I/O modules
• Data Recovery Services prevents data loss during power interruptions
• Optional battery is available for extended runtime.
JENE-PC3000e & JENE-PC6000e
EMBEDDED CONTROLLERS
Page 2
Specifications
JENE-PC3000E JENE-PC6000E
PLATFORM
Operating System QNX RTOS (Real-Time Operating System) QNX RTOS (Real-Time Operating System)
Processor PowerPC 405EX 400 MHz PowerPC 440EP 524MHz
Memory 256 SDRAM & 128 MB Serial Flash 128 SDRAM & 128 MB Serial Flash. Optional 256 MB DDR RAM
SRAM Data Recovery Service Yes Yes
Real-Time Clock Yes Yes
Oracle Hotspot Java 5 VM Yes Yes
Niagara AX Version v3.7.106 or later v3.6 or later
COMMUNICATION PORTS
Ethernet Port Two 10/100 Mbps Ethernet Ports (RJ-45 connectors) Two 10/100 Mbps Ethernet Ports (RJ-45 connectors)
RS-232 Port One 9 pin D-Shell connector on base board One 9 pin D-Shell connector on base board
RS-485 Port One non-isolated, 3-screw connector on base board One non-isolated, 3-screw connector on base board
32 Pin Option Card Slots Two on base board Two on base board
CHASSIS
Construction Base: Plastic, DIN rail or screw mount options. Cover: Plastic Base: Plastic, DIN rail or screw mount options. Cover: Plastic
Cooling Internal air convection Internal air convection
Dimensions 6.38” (162mm) W x 4.0” (101.6mm) H x 2.44” (62mm) D 6.38” (162mm) W x 4.0” (101.6mm) H x 2.44” (62mm) D
ENVIRONMENT
Operating Temperature Range 0 to 60°C (32 to 140°F) 0 to 60°C (32 to 140°F)Operating Temperature Range w/ optional battery kit
0 to 50°C (32 to 122°F) 0 to 50°C (32 to 122°F)
Storage Temperature 0 to 70°C (32 to 158°F) 0 to 70°C (32 to 158°F)
Relative Humidity Range 5 to 95 %RH, non-condensing 5 to 95 %RH, non-condensing
AGENCY LISTINGS
Compliance
UL 916, FCC part 15 Class B, RoHS Compliant, CE,
C-UL listed to Canadian Standards Association (CSA) C22.2 No.
205-M1983 “Single Equipment”, C-tick (Australia)
UL 916, FCC part 15 Class A, RoHS Compliant, CE,
C-UL listed to Canadian Standards Association (CSA) C22.2 No.
205-M1983 “Single Equipment”, BTL B-BC BACnet Building
Controller listed when the BACnet driver is installed and configured
POWER OPTIONS (USED ONLY WHEN A JM34-160810 34 POINT I/O MODULE IS NOT PRESENT)
JENE-PC-PWR or JENE-PC-PWR-UN Max 1; Direct connect (Pin compatible) Max 1; Direct connect (Pin compatible)
JENE-PC-WWPM-120 Max 1; Barrel connect external 15 Vdc power supply Max 1; Barrel connect external 15 Vdc power supply
JENE-PC-BPPMMax 1; Provides up to 10 minutes of runtime during power outages or disruptions
Max 1; Provides up to 10 minutes of runtime during power outages or disruptions
I/O EXPANSION MODULE OPTIONS
JM34-160810 - 34 Point I/O Max 1 Max 1
JM16-080404 - 16 Point I/O Max 2 with JM34-160810 or Max 4 without JM34-160810 Max 2 with JM34-160810 or Max 4 without JM34-160810
J-T-IO-16-485 - Remote 16 Point I/O Max 16 Max 16
INTERNAL COMMUNICATION OPTION CARDS
JENE-PC-LONCARD Max 2 Max 2
JENE-PC-485 Max 2 Max 2
JENE-PC-232 Max 2 Max 2
JENE-PC-GPRS-W Max 1 Max 1
JENE-PC-ZWAVE-US Max 1 Max 1
JENE-PC3000e & JENE-PC6000e
EMBEDDED CONTROLLERS
Page 3
Ordering InformationJENE-PC SERIES
PART NUMBER PART DESCRIPTION
JENE-PC3000eDIN mount JENE-PC3000e controller, using PowerPC 405 400Mhz processor, 256MB DDR2 RAM, 128MB Serial Flash, 512MB Static RAM (SRAM). Powered by one of the two separate plug-in power supply modules, or by wall mount AC power adapter. Controller supports optional I/O expansion modules and internal communications option cards.
JENE-PC6000e JENE-PC6000e-USA
DIN mount JENE-PC6000e controller, using PowerPC 440 524Mhz processor, 256MB DDR RAM, 128MB Serial Flash, 512MB Static RAM (SRAM). Powered by one of the two separate plug-in power supply modules, or by wall mount AC power adapter. Controller supports optional I/O expansion modules and internal communications option cards.
POWER SUPPLY OPTIONS (USED ONLY WHEN A JM34-160810 34 POINT I/O MODULE IS NOT PRESENT)
PART NUMBER PART DESCRIPTION
JENE-PC-PWR JENE-PC series DIN-mountable power supply; 24 Vac/dc input, 15Vdc at 30W output.
JENE-PC-PWR-UN JENE-PC series DIN-mountable power supply; Universal 90–263 Vac input, 15Vdc at 30W output.
JENE-PC-WWPM-120 JENE-PC series Wall Power Adapter (Wal-Wart), 120Vac, 60Hz, used to power JENE-PC series controller only.
JENE-PC-BPPM JENE-PC series Battery Kit. Provides up to 10 minutes of runtime during power outages and disturbances.
I/O EXPANSION MODULE OPTIONS
PART NUMBER PART DESCRIPTION
JM34-160810 JM34-160810-USA
JENE-PC Series DIN mountable, combined 34 points I/O with 24V isolated power module, used to provide I/O points as well as power the controller from a dedicated, external, Class-2, 24Vac transformer or a 24Vdc power supply.
JM16-080404 JM16-080404-USA
JENE-PC Series DIN mountable, 16 point I/O module.
J-T-IO-16-485 JENE-PC Series Remote I/O RS-485 Module DIN-mountable RS-485 comm module that provides 16 points I/O
INTERNAL COMMUNICATION OPTION CARDS
PART NUMBER PART DESCRIPTION
JENE-PC-LONCARDJENE-PC Series FTT-10A LON (LonWorks) option card with a 2-position removable screw-terminal connector plug. LON driver must be purchased separately.
JENE-PC-485 JENE-PC Series Dual, optically-isolated, Port RS-485 option card with two 3-position removable screw-terminal connector plugs
JENE-PC-232 JENE-PC Series Single port RS-232 option card, with a DB-9M connector. Supports baud rates up to 115200.
JENE-PC-GPRS-WJENE-PC Series GSM cellular modem option card using GPRS (General Packet Radio Service), with onboard socket for SIM card, and a Wyless SIM.
JENE-PC-ZWAVE-USJENE-PC Series Z-Wave wireless serial gateway between the JENE’s NiagaraAX station and an RF wireless Z-Wave domain. Includes RP-SMA coax tilt-and-swivel antenna.
Dimensions
2.50”(63.5mm)
4.00”(101.6mm)
3.75” (95.3mm)
6.72”(170.7mm)
0.170” Dia.(4.32mm)
JENE-PC3000e and JENE-PC6000e
JENE-PC3000e & JENE-PC6000e
EMBEDDED CONTROLLERS
© 2015 Lynxspirng, Inc. ALL RIGHTS RESERVED
07-2015
www.lynxspring.com 1210 NE Windsor Drive, Lee’s Summit, MO 64086
877-649-5969 | [email protected]
JENEsys® is a registered trademark of Lynxspring, Inc.Niagara Framework® is a registered trademark of Tridium, Inc.
JENEsys® Platform
The JENEsys® platform (building operating system) is an open, unified, operational and informational system that combines equipment and device connectivity, integration and interoperability, supervision and control, energy management, visualization and actionable information (data & analytics) into a single, integrated architecture within a cyber-secured environment. JENEsys® is scalable and allows organizations to continually build off the same network deployment and add additional applications as desired.
The deployment of JENEsys® hardware and software is the method by which building automation is expertly configured to a client’s best needs. JENEsys® enables users to deploy optimal energy and facility operational strategies, capitalize on accurate and concise intelligence relating to the performance of their facilities, reduce energy consumption and costs, gain knowledge of individual usage and trends related to their building systems and equipment from one source, all within a cloud or hosted environment.
• Choice – eliminates building managers and owners from being held captive to proprietary, closed technologies
• Enables multi-vendor integration and interoperability between devices from different manufacturers and disparate systems
• Flexibility/Options – allows facility managers, operators and owners to purchase different products from different manufacturers and choose the solutions that best fit their specific needs
• Simplifies facility operations – users can manage all of their diverse systems via a single, easy-to-use, web-based interface
• Combines the capabilities of network management, protocol conversion, distributed control, and the user interface into a single software solution that can operate on a wide range of hardware platforms from the very small to the very large
• API’s are available to enable independent third parties to develop complementary, enterprise applications that can work effectively with the system
• Data from the system is easily stored and retrieved from a common database and can be used throughout the system
• Future Expansion – offers support for a wide range of applications and the scalability to easily add future service and product upgrades
• Building managers and operators can continue to work with the products and vendors they trust, while gaining all the benefits of an integrated and interoperable system
• Provides operational efficiencies that reduce business risk
• Makes it easier to control and manage buildings and realize facility operational efficiencies, ensure occupant comfort and code compliances
• Reduces system complexity and costs. Maximizes lifetime value of building systems and equipment
• One platform that can be supported by whatever vendor or vendors a building owner, operator or facility manager chooses
147
*
2580
369#
LAN/WAN
Building SecurityEnergy Management
Utility MeteringAsset Monitoring
HVAC
Lighting
Card Access& Intrusion
CCTV
DVR
Open ADR &Generation
Plant Control
Firewall
INTERNET
AX SupervisorCommand & Control
Remote ProBuilderor Browser
Building Automation
LYNX CyberPro™Key
Cyber Security
Remote Applications
Graphical User Interface
Energy Analytics & Exception Reporting