JET-Rooflight Basement System Type Swith S-connection rail system
... the secure connection to the roof
Bro
ch
ure
No
. 1
.2.4
.1
P R O D U C T OV E R V I E W
very good light yield and outstanding
design due to optional RAL 9002 colour
coating
permanent secure connection of the
roof sheeting to the basement with
help of the, as an extra available,
S-connection rail system
The requirements of DIN 18234-3
(version 03 / 03) are fulfilled without
additional site-work
Reliable drainage of water and
condensate thanks to the 8° incline of
the continuous rooflight bearing
available in 5 construction heights:
25 cm
40 cm
45 cm
50 cm
55 cm
statical calculated
Flä
che
ab
schn
eid
en
Advantage of the connection rail:
The assembling of the continuous roof-
lights can be made independently to
the connection of the roof sheeting.
JET-rooflight basement system type S with S-connection rail system
detail with connection rail type S
beading fillers on site
Continuous Rooflights with Polycarbonate Chambered Panels
Industrial Construction Architecture SHEV-Technology & Customer Service
detail: S 25
op
tiona
l25
cm
roof heat insulation on site
vapour barrier on site
sheet metal flashingon site fortrapezoidal sheet metaland insulation
exchangeon site
option:connection rail type S
with sealing profile
8º
10 cm
detail: S 40
option:non-flammable heat insulationaccording DIN 4102-1,60 mm delivery height 30 cm, for adaption of insulation thickness on site (JET or on site)
roof heat insulation on site
vapour barrier on site
25 c
m15
cm
op
tiona
l
40 c
m
10 cm
option:connection rail type S
with sealing profile
8º
JET-rooflight basement system type S
option:non-flammableheat insulationaccording DIN 4102-1,60 mm,(JET or on site)
Lighting technology
The coating of the vertical basements in RAL 9002 significantly increases the intensity of illumination under
the rooflight compared with a galvanized vertical basement!
It is the same when you compare a vertical galvanized basement with an inclined S-basement in RAL
9002. The intensity of illumination of the coated basement is higher, even if it has a 20 cm smaller upper
clear width (see below table).
Additional advantage for you:
A smaller rooflight order width:
- lower price
- less loss of heat in winter
- less heating in summer
Sample calculation according DIN 5034, part 6 (version 06 / 95)
Dimensions of hall: 50 m x 20 m, height: 10 m, 1 continuous rooflight integrated, length: 40 m, basement
height: 50 cm, galvanized, as alternative coated in grey white. In case of inclined basement the upper
incidence of light dimension is reduced by 20 cm in the width.
detail: S 45, S 50, S 55
option:connection rail type S
with sealing profile
8º
option:non-flammableheat insulationaccording DIN 4102-1,60 mm delivery height 30 cm, for adaption of insulation thicknesson site (JET or on site)
vapour barrier on site
roof heat insulation on sitesample: 15 cm thickness
support plate45,5 / 4,5 cm(JET or on site)
splices have to be sealed vapour proof on site
10 cm
20 /
25 /
30 c
m25
cm
45 /
50 /
55 c
m
45,5 cm
4,5
cm
The choice of the necessary basement height
takes place due to the addition of on site used
thicknesses resp. construction heights of
trapezoidal sheet
+ heat insulation
+ sealing
+ necessary free basement height.
For SHEV according DIN 18232 basement height
minimum 25 cm over the upper edge of the roof!
Average intensity of illumination Ep of the hall
clear roof opening width(lower edge basement
system)2,00 m 3,00 m 4,00 m 5,00 m Skizze
vertical basement,50 cm high,
coated in grey whiteRAL 9002, luminous
reflectance value = 67 %
125 lx 193 lx 262 lx 330 lx
vertical basement, 50 cm high,
galvanized, luminous reflectance value = 36 %
114 lx 181 lx 249 lx 317 lx
basement type S,50 cm high,
coated in grey whiteRAL 9002, luminous
reflectance value = 67 %
115 lx 183 lx 252 lx 320 lx
basement type S, 50 cm high,
galvanized, luminous reflectance value = 36 %
108 lx 176 lx 243 lx 311 lx
rooflight order width
clear roof opening width
rooflight order width
clear roof opening width
clear roof opening width – 20 cm
Symbolic presentation of non-self supporting basements
01. rooflight head piece basement
02. rooflight basement long side
03. basement corner angle
04. basement case corner
05. basement joint connector
06. cover for basement joint
07. push-pull brace
08. push-pull diagonal brace
09. bearing
10. head piece cross bracing
11. cross bracing
04
03
0110
09
0502
07
11
08
06
distance fro
m basement joint
to the next push-pull b
race
distance fro
m
head piece to
first push-pull
brace
distance fro
m
push-pull
brace to
push-pull
brace
Symbolic presentation of self supporting basements
0103
04
07
08
06
05
02
09
11
10
distance m
iddle of
girder to m
iddle
of girder
distance
head piece
to first m
iddle
of girder
01. rooflight head piece basement
02. rooflight basement long side
03. basement corner angle
04. basement case corner
05. basement joint connector
06. cover for basement joint
07. push-pull brace
08. push-pull diagonal brace
09. bearing
10. support plate
11. spacer according
statical need
VdSVdS-approved manufacturer for
smoke and heat exhaust systemsLIGHT DOMES ~ ROOFLIGHTS ~ SHEV ~ SPECIAL GLASS AND GRILLODUR® ~ SURFACE VENTILATORS
JET Tageslicht & RWA GmbH
Weidehorst 28D- 32609 Hüllhorst
Tel. +49 (0) 5744 / 503-0Fax +49 (0) 5744 / 503-40
Certified in com-pliance withDIN EN ISO
9001
Bro
ch
ure
No
. 1
.2.4
.1
Valid
fro
m d
ate
of p
ublic
atio
n un
til n
ew
ed
itio
n. U
pd
ate
d: A
ugus
t 201
1. N
ot r
esp
ons
ible
for p
rintin
g e
rrors
, mist
ake
s a
nd te
chn
ica
l alte
ratio
ns.
Industrial Construction Architecture SHEV-Technology & Customer Service