jetstream - infobuild · the use of the jetstream induction flow optimizer has the following...

5
The Atlas unit heaters can be supplied with the innovative JETSTREAM induction flow optimiser, in the manual version or the motorised version for wall-hung or ceiling installation. The lower outlet temperature of the air from the units means less stratification of the hot air in the building and less operating time for the same ambient temperature. In addition, the increased air throw means greater uniformity of the temperature at floor level, with an expansion of the comfort zone, and consequently the possibility to install smaller and more silent appliances. Induction Flow Optimizer Jetstream 1

Upload: others

Post on 29-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Jetstream - INFOBUILD · The use of the JETSTREAM induction flow optimizer has the following advantages: a) Energy saving: – reduced hot air stratification within the building

The Atlas unit heaters can be supplied with the innovative JETSTREAMinduction flow optimiser, in the manual version or the motorised version for

wall-hung or ceiling installation. The lower outlet temperature of the air from

the units means less stratification of the hot air in the building and less

operating time for the same ambient temperature. In addition, the increased

air throw means greater uniformity of the temperature at floor level, with an

expansion of the comfort zone, and consequently the possibility to install

smaller and more silent appliances.

Induction Flow OptimizerJetstream

1

Page 2: Jetstream - INFOBUILD · The use of the JETSTREAM induction flow optimizer has the following advantages: a) Energy saving: – reduced hot air stratification within the building

INFLUENCE AREA

Temp. underthe ceiling 30°C

MINUTES MINUTES

Time necessary to reachthe room temperature of 18°C

Time necessary to reachthe room temperature of 18°C

Air speed 0.25 m/s Air speed 0.1 m/s18°C

Temperatureunder the ceiling 19-20°C

18°C

INFLUENCE AREA

Technical characteristics:The use of the JETSTREAM induction flow optimizer

has the following advantages:

a) Energy saving:

– reduced hot air stratification

within the building.

– reduced operating time

of the units with the same

ambient temperature.

Energy saving varies

between a minimum of 5%

and a maximum of 15%,

with maximum amortization in two seasons.

b) Environment comfort advantages:

– increased floor-temperature uniformity

with greater comfort area.

– possibility to install smaller and quieter units,

due to the increase of the throw.

Four versions are available:

• Manual for wall installation (all sizes)

• Manual for ceiling installation (all sizes)

• Motorized for wall installation (sizes 1÷7 only)

• Motorized for ceiling installation (all sizes)

The manually controlled version calls for manual orientation

of the fins and for them to be locked using a special threaded rod.

The motorized version is supplied

with single phase motor that can be controlled by the remote switch.

Air produced by a unit heaterWITHOUT induction optimizer

Air produced by a unit heaterWITH induction optimizer

2

Page 3: Jetstream - INFOBUILD · The use of the JETSTREAM induction flow optimizer has the following advantages: a) Energy saving: – reduced hot air stratification within the building

368

422

476

530

584

638

793

900

1010

1117

1,4

1,7

1,8

2,0

2,2

2,4

2,6

3,0

3,4

3,7

Amm

WEIGHTKg

O - 1O - 2O - 3O - 4O - 5O - 6O - 7O - 8O - 9O - 10

V - 1V - 2V - 3V - 4V - 5V - 6V - 7V - 8V - 9V - 10

MODEL

Dimensions and Weight

O (HORIZONTAL DISCHARGE)

V (VERTICAL DISCHARGE)

Controls

Remote switch

3

Page 4: Jetstream - INFOBUILD · The use of the JETSTREAM induction flow optimizer has the following advantages: a) Energy saving: – reduced hot air stratification within the building

8

11

14

16

20

25

-

-

-

-

13

16

19

21

26

31

-

-

-

-

5,5

7,5

10

12

15

18

24

26

28

30

9

13

15

15

18

23

29

32

34

37

-

-

-

-

-

-

18

20

21

22

-

-

-

-

-

-

23

25

26

28

4

4,5

5

5,5

6

7

-

-

-

-

4

5

6,5

6,5

7

8

-

-

-

-

3

3,5

4

4,5

5

6

7

9

11

12

3

4

5,5

5,5

6

7

8

10

13

14

-

-

-

-

-

-

6

7

8

9

-

-

-

-

-

-

7

8

9

10

5,5

8

11

12

13

14

-

-

-

-

4

6,5

8

9

10

12

13

15

18

19

-

-

-

-

-

-

11

12

13

14

0123456789

0123456789

SABIANAUNIT HEATER

SIZE

SABIANAUNIT HEATER

SIZE

WITHOUT JETSTREAM

WITHOUT JETSTREAM WITH JETSTREAM

4P

4P 4P6P 6P8P 8P

4P 4P6P 6P 6P8P 8P 8P

WITH JETSTREAM AT 60° WITH JETSTREAM AT 120°

INSTALLATION HEIGHT H (m)

MAXIMUM THROW L (m)

Mounting heightsand Air throwa) Wall installation for horizontal discharge:

b) Ceiling installation for vertical discharge:

Speed 0.1 m/s

Speed0.1 m/s

Speed0.1 m/s

MAXIMUM THROW L (m)

LOUVRESINCLINATION 90°

LOW

EST

HEI

GH

T 3m

THROW 30° EVERY SIDE

60° 120°

THROW 60° EVERY SIDE

HEI

GH

T H

m

HEI

GH

TH

m

4

Page 5: Jetstream - INFOBUILD · The use of the JETSTREAM induction flow optimizer has the following advantages: a) Energy saving: – reduced hot air stratification within the building

5JE-LT-EN

-07-14

Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italy

phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576

fax +39.02.9777282 / +39.02.9772820

www.sabiana.it • [email protected]

The descriptions and illustrations provided in this publication

are not binding: Sabiana reserves the right, whilst maintaining

the essential characteristics of the types described

and illustrated, to make, at any time, without the requirement

to promptly update this piece of literature, any changes

that it considers useful for the purpose of improvement

or for any other manufacturing or commercial requirements.