Water PurificationSelection Guide

www.johnmorrisgroup.com

Page 2: John Morris Group Water Purification Brochure

www.johnmorrisgroup.com 2

Our portfolio of water purification systems include a broad range of ultrapure, pure & Reverse Osmosis (RO) water designed for all labs (in both validated & non-validated environments).

To ensure you select the right instrument, follow these steps:

Define the suitable applications of use (this identifies the level of purity & ‘type’ of water required) Establish the initial source of water to be purified (ie from a tap or pure water) Determine how much water you need (litres per day or hour)

For adherence to strict quality IQ/OQ standards

(where validation & recording of data is essential)

For greater choice & flexibility in supplying daily water

requirements for various usage applications

Applications Water ‘Type’

1 12 23 3

Water ‘Type’Applications

Type 1

Ultrapure Water

Type 2

Pure Grade Water

Type 3

Pure Grade General Lab

Resistivity (MΩ.cm @ 25°C) >18 >1.0 >0.05TOC ppb (µg/L) <10 <50 <200Pyrogens (EU/mL) <0.03* n/a n/aParticulates >0.2 µm (units/mL) <1 n/a n/aSilica (ppb) <10 <10 <1,000Bacteria (cfu/mL) <1 <100 <1,000

Highest grade of water purification - suitable for critical lab applications

Very low organic contaminants - suitable for general lab needs

or to feed Type 1 water

RO water suitable for non-critical applications or to feed Type 1 water

* With BioPak Polisher as Application Pak Water specifications are guidelines only

Hydroponics -IC (Ion Chromatography) - -ICP-MS & ICP-OES - -In Vitro Fertilization (IVF) - -Kjeldahl Analyser - -Langmuir Monolayer Analysis - -LC (Liquid Chromatography) - -LC-MS - -Lithography - - Microarray - -Microbiological Culture Media Preparation - -NP Analysers (Nitrogen-Phosphorus Analysers) -Nuclease-Free Water / RNase-Free Water - -Particulate Analysers - -PCR (Polymerase Chain Reaction) - -pH Measure - -Semiconductors - -Spectrophotometry - -Stability Test Chambers - -Titration -TOC Analysers (Total Oxidisable Carbon) - -Turbidimeter -UHPLC (Ultra HPLC) - -VOC (Volatile Organics Analysis) - -Weatherometers - -

Applications by Water ‘Type’

‘Types’ of Water Purification

AA (Atomic Absorption) - -Animal Care Facilities - Animal Watering - - Aquariums - - Autoclaves - - Blotting (Northern, Western, Southern) - -BOD (Biological Oxygen Demand) - -Buffers Preparation -Capillary Electrophoresis - -Cell Culture Media & Buffers - -Clinical and Biomedical Laboratories -COD (Chemical Oxygen Demand) - -Colorimetric Tests & Measures -DHPLC - -Dissolution Testing -DNA Sequencing - DNA Sequencers - -Electrophoresis - -Endocrine Disruptors Analysis - -Fuel Cells - -GC (Gas Chromatography) - -GFAA (Graphite Furnace Atomic Absorption) - -Glassware Washing / Washers - Heating Baths (water for) - - Histology -HPLC (High Performance Liquid Chromatography) - -Hydrogen Generators - -

Page 3: John Morris Group Water Purification Brochure

Australia - Free Call: 1800 251 799 3 New Zealand - Toll Free: 0800 651 700

To ensure you select the right water purification instrument for your needs, contact John Morris Group for professional assistance

Sales Consumables Accessories Service & Repair

Type 1 & 2 Combined

Required Water Purity Water Source

Resistivity(MΩ.cm @

25°C)L/dayMax

L/minMax

Water Flow Rate TOCppb (µg/L)

Bacteria (cfu/mL)

Suitable Product

Page

Type 1 & 3 Combined

Type 1

Type 2 (DI)

Type 3 (RO)

Biomedical Water

Ultrapure

Pure (DI)

Ultrapure

Pure (RO)

Ultrapure

Ultrapure

Ultrapure

Ultrapure

Pure

Pure

Pure

RO

Tap

Tap

Tap

Tap

Pure

Pure

Pure

Pure

Tap

Tap

Tap

Tap

Tap

2.0

2.0

2

15

2.0

2.0

>0.5

12

2.0

Gravity Fed

Gravity Fed

0.4

4

18.2

>5

18.2

18.2

18.2

18.2

18.2

>5

>5

>5

<5

<30

≤5

≤5

≤5

≤5

<20

<30

<30

<30

<0.1

<0.1

<0.1

<10

<0.1

<10

<10

<10

<0.1

Typical Rejection >99%

Typical Rejection >99%

10 <30

<0.1360

250

4

<0.1 4

5

5

5

5

6

6

6

7

7

Milli-Q Advantage A10

Milli-Q Reference / A+

Simplicity

Super-Q Plus

Elix Advantage

Elix Essential

Elix Reference

RiOs Systems

AFS Systems

Milli-Q Integral

Milli-Q Direct

250

200

10

12,000

300

300

300

8,000

3,000

Instrument Summary

TOC: Total Organic Carbon (water quality measurement - level of carbon present in organic compounds) ppb: parts per billion DI: Deionized Water RO: Reverse Osmosis

Page 4: John Morris Group Water Purification Brochure

www.johnmorrisgroup.com 4

Ultrapure & Pure Water from the Tap

Milli-Q Integral

Milli-Q Direct

Type 1 & 2 Water - combined in one unit Ultrapure water (Type 1) dispensed via up to 3 Q-PODs Pure water (Type 2) dispensed via E-POD Manual or automatic water delivery (with high or low flow) I/Q & OQ validation - exact water quality assured TOC monitor Application Paks to remove specific contaminants

Type 1 & 3 Water - combined in one unit

Ultrapure water (Type 1) dispensed via Q-POD Type 3 (RO) pure water sourced either through tank valve or to feed instruments (such as a glassware washing machine) I/Q & OQ validation - exact water quality assured Up to 350 L reservoir tank Application Paks to remove specific contaminants

Page 5: John Morris Group Water Purification Brochure

Australia - Free Call: 1800 251 799 5 New Zealand - Toll Free: 0800 651 700

Ultrapure Water from Pure Water

Type 1 Water Type 1 Water Type 1 Water

Q-POD dispenses water (optional) Application Paks to remove specific contaminants TOC indicator included with Milli-Q Reference A+

A portable & basic solution - place anywhere in the lab Integrated reservoir Recirculates water to maintain quality

A high-flow water system providing the ‘final polish’ to RO, distillation or deionization water No degrading of water quality over time

Milli-Q Reference / A+ Simplicity Super-Q Plus

Milli-Q Advantage A10

Type 1 Water Ultrapure water (Type 1) dispensed via up to 3 Q-PODs TOC & resistivity monitoring Internal UV lamp for low TOC Type 1 Application Paks to remove specific contaminants Compact - place under the bench or on the wall

Page 6: John Morris Group Water Purification Brochure

www.johnmorrisgroup.com 6

Pure Water from Tap Water

Type 2 Water Type 2 Water

Intelligent RO controls water consumption Constant product flow rate & optimal water quality

Pure water stored in a tank Water sourced via valve or fed directly to lab instruments

Elix Advantage

Elix Essential Elix Reference

State-of-the-art electrodeionization technology ensures delivery of constant & reliable Type 2 water - replaces chemical regeneration of conventional ion-exchange systems plus removes chemical or resin disposal needs

Elix systems provide the best feed water for all Milli-Q ultrapure systems

Type 2 Water

Pure water dispensed via up to 3 E-PODs I/Q & OQ validation - exact water quality assured Compact - place anywhere in the lab Application Paks to remove specific contaminants

Page 7: John Morris Group Water Purification Brochure

Australia - Free Call: 1800 251 799 7 New Zealand - Toll Free: 0800 651 700

RO Water from Tap Water

Application Pak Polishers

Best-in-Class Elix® EDI Technology

Biomedical Water Solutions

Ideal for non-critical lab applications (glassware rinsing, hydroponics, water baths) Feed water for humidifiers, autoclaves, glassware washers & ultrapure water systems Choose models from 5 to 200 L

Elix® EDI module uses electrodeionization to remove remaining ions - included in all Elix (Type 2) systems plus Milli-Q Integral (Type 1)

Consistent high-quality water - resins do not degrade (as no expose to harsh regeneration chemicals or removed from the system) No extra softeners needed Minimal electricity consumption - uses equivalent of electric light bulb energy Uninterrupted water production - continuously regenerated ion-exchange resins eliminate hazardous chemical regeneration or costly resin replacement

Application Pak polishers can be added to PODs to remove specific contaminants that impact specific applications (HPLC, LC-MS, MALDI-ToF-MS, IC, ICP, AA & most analytical techniques)

Provides superior & consistent water quality Complies with clinical laboratory reagent water (CLRW) guidelines Choose models from 8 to 150 L/h flow rates Full monitoring & water quality archiving capabilities

RiOs Systems

MilliPak Polisher BioPak Polisher LC-Pak Polisher VOC-Pak Polisher EDS-Pak Polisher

AFS Systems

RiOs systems are suitable for reliable, constant production of Reverse Osmosis (RO) water

Bacteria-free &particulate-free water

Pyrogen-free &nuclease-free water

Water for ultra-traceorganic analysis

Water for volatile organic compounds analysis

Water for endocrinedisrupters experiments

Significantly reduce water consumption - ideal where sample throughput often greater than several thousand samples per day

Page 8: John Morris Group Water Purification Brochure

www.johnmorrisgroup.com

Whilst John M

orris Group has taken every care to ensure the accuracy of information contained within this Guide, no responsibility for errors or om

issions is accepted.

Australia

Address 61-63 Victoria Avenue Chatswood NSW 2067 AustraliaFree Call 1800 251 799Enquiries +61 (0) 2 9496 4200 Email [email protected]

At John Morris Group we offer more than just the product - we provide the full package -