junction 7 - cloncumber - layout plan · turbine & hardstand proposed 4.5m access road existing...

1
Turbine & Hardstand Proposed 4.5m Access Road Existing Ground Contour LEGEND Temporary Hardstand Areas Existing Access Road Proposed Temporary Access Track Temporary Hardstand Areas Planning Boundary ORIGINAL DRAWING SIZE A1 - (841 x 594) G F E D C B A Sheet FTC-A1-2006 rev. C (template filed in O:Acad\Templates\Autocad) (May 2007) - template externally referenced G F E D C B A 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Rev. App'd Drawn Chk'd Description Name of Client Name of Job Title of Drawing Scales Used Dwg. No. Rev. Use figured dimensions only. on the project for which the document was originally issued. of Fehily Timoney & Company as copyright holder except as agreed for use or stored in any retrieval system of any nature without the written permission No part of this document may be reproduced or transmitted in any form Do not scale. If in doubt - Ask! Revision History CONSULTANTS IN ENGINEERING & ENVIRONMENTAL SCIENCES Date Rev Origin (Gemma White) W: www.fehilytimoney.ie, E: [email protected] T:+353-21-4964133, F:+353-21-4964464 Core House, Pouladuff Rd, Cork, Ireland. T:+353-1-6583500, F:+353-1-6583501 J5 Plaza, North Park Business Park, North Road, Dublin 11, Ireland This Drawing was printed to A1- 0m 10m 20m 30m 40m 50m 60m 70m 80m 90m 100m Scale 1:1000 ORIGINAL DRAWING SIZE A1 - (841 x 594) SCALE HORIZ. 100 20 50 10 0 10 Rev. App'd Drawn Chk'd Description Name of Client Name of Job Title of Drawing Scales Used Dwg. No. Rev. Use figured dimensions only. on the project for which the document was originally issued. of Fehily Timoney & Company as copyright holder except as agreed for use or stored in any retrieval system of any nature without the written permission No part of this document may be reproduced or transmitted in any form Do not scale. If in doubt - Ask! 10 10 0 20 50 SCALE - VERTICAL 100 Revision History Date Rev Origin ELEMENT POWER IRELAND MAIGHNE WIND FARM JUNCTIONS 7 - 9 SIGHT DISTANCE LAYOUT PLAN LE14-731-04-121 O:\ACAD\2014\LE14\731\04\LE1473104_121 1:1000 2UGQDQFH 6XUYH\ ,UHODQG /LFHQFH 1R (1 2UGQDQFH 6XUYH\ ,UHODQG DQG *RYHUQPHQW RI ,UHODQG OS Map No's. 2982 C,D, 3051_B, 3052_A, B,D, 3119, 3120, 3185, 3186, 3252 B,D, 3317 B,D, 3380 & B, 3443, 3504, 3505 A, 3444 A,B,C,D, 3253 A,B,C,D, 3254 B,C,D, 3255 A, A A 3189 A,B,C,D, 3188 A,B,D, 3187 A,B,C,D, 3122 A,B,C,D, 3190 C,D, 3256 B, 3257 A,B, 3258 B, 3054 D, 3055C,D, 3056 C, 3124 A,B, 3125 A, 3057 & C,2987, 2988, 2919 D Cork A GW AR TR 22-Sep-15 ISSUE FOR RFI JUNCTION 7 - CLONCUMBER - LAYOUT PLAN Scale 1:1000 JUNCTION 8 - HORTLAND - LAYOUT PLAN Scale 1:1000 JUNCTION 9 - HORTLAND - LAYOUT PLAN Scale 1:1000 Junction Key Junction Key 1 2 3 4 5 6 8 9 7 Visibilty Envelope

Upload: others

Post on 03-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JUNCTION 7 - CLONCUMBER - LAYOUT PLAN · Turbine & Hardstand Proposed 4.5m Access Road Existing Ground Contour LEGEND Temporary Hardstand Areas Existing Access Road Proposed Temporary

Turbine & Hardstand

Proposed 4.5m Access Road

Existing Ground Contour

LEGEND

Temporary Hardstand Areas

Existing Access Road

Proposed Temporary Access Track

Temporary Hardstand Areas

Planning Boundary

ORIGINAL DRAWING SIZE A1 - (841 x 594)

G

F

E

D

C

B

A

Sheet FTC-A1-2006 rev. C (template filed in O:Acad\Templates\Autocad) (May 2007) - template externally referenced

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

Rev

.

Ap

p'd

Dra

wn

Ch

k'd

Description

Name of Client

Name of Job

Title of Drawing

Scales Used

Dwg. No. Rev.

Use figured dimensions only.on the project for which the document was originally issued.of Fehily Timoney & Company as copyright holder except as agreed for useor stored in any retrieval system of any nature without the written permissionNo part of this document may be reproduced or transmitted in any form

Do not scale. If in doubt - Ask!

Revision History

CONSULTANTS INENGINEERING &ENVIRONMENTALSCIENCES

Date

Rev Origin

(Gemma White)

W: www.fehilytimoney.ie, E: [email protected]

T:+353-21-4964133, F:+353-21-4964464Core House, Pouladuff Rd, Cork, Ireland.

T:+353-1-6583500, F:+353-1-6583501

J5 Plaza, North Park Business Park,North Road, Dublin 11, Ireland

This Drawing was printed toA1-

0m 10m

20m

30m

40m

50m

60m

70m

80m

90m

100m

Scale 1:1000

ORIGINAL DRAWING SIZE A1 - (841 x 594) SCALE HORIZ.10020 5010010

Rev

.

Ap

p'd

Dra

wn

Ch

k'd

Description

Name of Client

Name of Job

Title of Drawing

Scales Used

Dwg. No. Rev.

Use figured dimensions only. on the project for which the document was originally issued.of Fehily Timoney & Company as copyright holder except as agreed for useor stored in any retrieval system of any nature without the written permissionNo part of this document may be reproduced or transmitted in any form

Do not scale. If in doubt - Ask!

1010

020

50SC

ALE

- VE

RTICAL

100

Revision History

Date

Rev Origin

ELEMENT POWER IRELAND

MAIGHNE WIND FARM

JUNCTIONS 7 - 9 SIGHT DISTANCE

LAYOUT PLAN

LE14-731-04-121O:\ACAD\2014\LE14\731\04\LE1473104_121

1:1000

Ordnance Survey Ireland Licence No. EN 0071415 © Ordnance Survey Ireland and Government of IrelandOS Map No's. 2982 C,D, 3051_B, 3052_A, B,D, 3119, 3120, 3185, 3186, 3252 B,D, 3317 B,D, 3380 & B, 3443, 3504, 3505 A, 3444 A,B,C,D, 3253 A,B,C,D, 3254 B,C,D, 3255 A,

A

A

3189 A,B,C,D, 3188 A,B,D, 3187 A,B,C,D, 3122 A,B,C,D, 3190 C,D, 3256 B, 3257 A,B, 3258 B, 3054 D, 3055C,D, 3056 C, 3124 A,B, 3125 A, 3057 & C,2987, 2988, 2919 D

CorkA G

WA

RTR 22-Sep-15 ISSUE FOR RFI

JUNCTION 7 - CLONCUMBER - LAYOUT PLANScale 1:1000

JUNCTION 8 - HORTLAND - LAYOUT PLANScale 1:1000

JUNCTION 9 - HORTLAND - LAYOUT PLANScale 1:1000

Junction KeyJunction Key

1

2

3

4

5

6

8

9

7

Visibilty Envelope