jxdh-6202qhx(m) 8 in 1 full function hd encoder

20
8 IN 1 FULL FUNCTION HD ENCODER 8 in 1 full function HD Encoder User’s Manual Your Best Choice! Your Best Choice! Version 1.1 2013.08.06 8 in 1 full function HD Encoder User Manual 8 in 1 full function HD Encoder

Upload: hani-zayed

Post on 11-Nov-2015

32 views

Category:

Documents


3 download

DESCRIPTION

JXDH-6202QHX(M) 8 in 1 Full Function HD

TRANSCRIPT

  • 8 IN 1 FULL FUNCTION HD ENCODER8 in 1 full function HD Encoder Users Manual

    Your Best Choice!Your Best Choice!Your Best Choice!

    Version

    1.12013.08.06

    8 in 1 full function HD Encoder

    User Manual

    8 in 1 full function HD Encoder

  • Chapter 1 Product introduction

    2

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    8 in 1 full-function professional HD Audio Video Encoder newly developed by Hongtushixun with

    multiplexer function. It comes with 8 HDMI Video or 8HD-SDI inputs(optional); Video supports

    MPEG-2 and H.264 Encoding format with higher encoding compression efficiency and excellent

    video quality; Audio supports MPEG-1 Audio Layer2LC-AAC, HE-AAC encoding format. In

    additional to the encoding function to 8 HDMI Audio Video signals, at the same time 1ASI input

    and 1IP input(optional, IP output is included) are available to MPTS output together with existed

    TS stream from encoding after they are multiplexed. It comes with 1group ASI multiplexing

    output(2 routes) and 1IP output port(optional, IP input is including), IP output supports 16 routes

    SPTS or 1MPTS output. IP and ASI stream output(consistent or inconsistent) is independent.

    You can choose H.264 encoding or MPEG-2 encoding for different input. In the H.264 encoding

    mode, each input can simultaneously output two streams with different resolution for different

    network requirements.

    Its higher integration and versatile design can effectively reduce cost of digital TV system. It can

    be widely used in different digital TV head-end system, Digital Terrestrial and IPTV digital TV

    systems.

    1.1 Overview

    1.2 Functions

    Support MPEG-2 and H.264 Video Encoding

    Support MPEG-1 Layer 2,LC-AAC or HE-AAC Audio Encoding

    Support PALNTSC video format

    Support supper lower bit rate encoding

    Support edit and insert PSI/SI

    Support VBR and CBR video encoding mode

    IP and ASI stream output(consistent or inconsistent) is independent

    Support IP output with 1MPTS or 16 SPTS

    In the H.264 encoding mode, each input can simultaneously output two streams with different

    resolution for different network requirements.

    Support real time monitoring output bit rate.

    Support Web Management

    High reliability design, stable operation, high performance and low cost

    1U Standard case unit

    1.3 Technical indicators

    Input

    8 HDMI inputs8 HD-SDI inputs(BNC interface) Optional

    1 ASI input(BNC interface)

    1 IP input(RJ45 port)Optionalincluding IP output

  • 3

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Video Encoding

    Format

    Encoding

    H.264/AVC High Profile compliant

    H.264/AVC Main Profile compliant

    H.264/AVC Baseline Profile compliant

    MPEG-2 MP@ML compliant

    *The video format is 4:2:0 with 8bits

    Optional,Including IP input

    Audio Sampling rate

    32 kHz 44.1kHz 48kHz

    H.264:VBR MPEG-2:CBRVBR

    AAC96/112/128/160/192/224/256/320/384Kbps

    MPEG-1 Audio Layer 2:192/224/256/320/384Kbps

    PSI/SI Inset

    ASI input bit rate 108Mbps(BNC-J12(75 Ohm)interface)

    IP input bit rate 860Mbps support 1 unicast multicast

    Support 1 IP MPTS inputunicast multicast

    IP Packages 1-7

    IP Package format 188 204

    MTU Max 1500

    Anti vibration Ability 300ms

    Interface 1 group with 2 ASI input BNC-Female(75 Ohm)

    Output bit rate Support max 108M bit rate, Max 256PID for each channel

    Output bit rate

    860Mbps support Unicast, Multicast and

    filtering empty packages

    Support 16 SPTS or 1MPTS output with max

    256 PID

    Package quantity

    Package format 188

    Interface Rj45 10/100M

    ManagementWEB support online upgrading, parameter

    guiding in or out.

    Language Chinese and English

    Audio Encoding

    Format

    MPEG-1 Audio Layer 2

    AAC-LC HE-AAC

    Video encoding rate

    H.264 0.8 -10Mbps MPEG-2 1.2 - 10Mbps

    Video encoding mode

    Audio encoding

    rate

    PAT PMT SDT NIT

    Multiplexing

    Function

    ASI Output

    IP Output

    Interface 1 10/100/1000Base-T RJ-45

    7

    Management

    function

  • 4

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    8 in 1 full function HD encoder Rear Panel

    Apply

    universally

    Size(LxWxH) 483mm44mm500mm

    Weight 4kg

    Temperature 0~45(working), -20~80reserving

    Power AC 100V10% 60Hz 220V10%, 50Hz

    Power Consumption

    25W

    1.4 Appearance and Description

    8 in 1 full function HD encoder Front Pannel

    POWER

    1

    ALARM

    ENCODER

    1 2 3 4

    5 6

    ASI IN

    IP IN

    2

    3

    4 8

    7

    6

    5

    CH

    12

    3

    4

    5

    6

    Encoding 1-8 channels input interface lock Indicator light(green)

    Encoding IP IN signal lock indicator light(green)

    Encoding bit rate overflow indicator light(green)

    Encoding ASI IN signal lock indicator light(green)

    The power indicatorred

    1

    AC110V-220V-50/60Hz

    ASI IN

    HDMI 8 HDMI 7 HDMI 6 HDMI 5

    2 5 8 16 17 18 19

    HDMI 4 HDMI 3 HDMI 2 HDMI 1RST

    IP IN

    IP OUT OUT

    ASI

    NMS

    43

    7

    91011

    15 14 13 12

  • 5

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    1 1 1GE input/output interfaceReset button Network management port

    ASI input interface4 57 ASI output homologous interface 16 Power switch

    89101112131415 1-8 channels HDMI Video/Audio input interface

    191817 Fuse Power Jack Ground terminal

    Chapter 2 Installation guide

    2.1 Acquisition Check

    When user open the package of the device, it is necessary to check the packaging materials of

    widgets, check items in the package according to packing list or the following items:

    8 in 1 full function HD encoder 1

    User Manual 1

    AC input power plug wire 1

    If any item is missing or mismatches with the list above, please contact the company

    immediately.

    2.2 Installation Preparation

    When user install the device, please follow the following steps,The details of installation will be

    described at the rest part of this chapter, user can also refer to the rear panel chart, this chapter

    mainly include the following content.

    Checking the possible device missing or damage during the transportation.

    Preparing relevant environment for installation.

    Installing Encoder.

    Connecting signal wires.

    Connecting communication port(optional).

    2.2.1 Devices Installation Flow Chart illustrated as follows

    Acquisition

    Check

    Fixing

    Device

    Connecting

    Grouding

    Wire and

    Power

    Cord

    Connecting

    Signal Wire

    Setting

    Parameter

    Running

    Device

  • 6

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    2.2.2 Environment Requirement

    Items Requirement

    Installation space

    When the devices are installed in several rows in the device room,their

    distance should be between 1.2~1.5m, and the distance to the wall should

    be no less than 0.8m.

    No conduction, and no dusting Mass resistivity of the antistatic flooring: 1X

    107~1X1010, Grounding current limiting resistance: 1M . Floor bearing:

    more than 450Kg/m

    2

    Floor of the

    equipment room

    Environment

    Temperature

    5~40(sustainable) 0~45 (short term)The air conditioner is

    recommended to install.

    Relative

    temperature20%~80% sustainable 10%~90% short time

    Pressure 86~105KPa

    Machine rooms

    window & door

    They must be sealed with dust proof ruber strip. And the windows should

    be installed with double glass and sealed strictly.

    Machine rooms

    wall

    Wall paper can be pasted, and flat paint can be used, but powdered paint

    isnt applicable.

    Fire prevention Machine room should be equipped with fire alarm system and extinguisher.

    Power supplyIt requires three sets of separate power supply system: device power, air-

    conditioner power and lighting power, device power provided by AC power.

    2.2.3 Grounding System design Requirements

    Each function modules good grounding design will guarantee reliable and stable operation of the

    device, also guarantee against lighting, anti-interference. Therefore, the system grounding must

    follow this rule.

    Outer conductor of coaxial cable and both ends of shielding layer should keep good electrical

    contact with surface of the metal chassis of connected devices

    Grounding conductor must use copper conductor to reduce the high frequency impedance,

    grounding wire must be as thick and short as possible

    Both ends of the ground wire connection point should confirm the electrical contact is good,

    and should be done anti corrosive processing.

    Prohibit using the other equipment as the part of the ground wires electrical connection.

    Conductor cross-sectional area between Cabinet and grounding wire of lightning protection

    should be equal or greater than 25mm .

    Cabinet Grounding

    Grounding terminal of each cabinet in same room should be separately connected to protected

    copper platoon, the grounding wire should be as short as possible, if the wiring is too long when

    the project installed, should be cut off to avoid grounding wire circling, conductor cross-sectional

    area between Ground terminal and ground platoon should be equal or greater than 25mm

    2.2.4

    2.2.5 Device Grounding

    Connect protective grounding terminal to protective grounding wire of assembly cabinet with wire.

    2

    2

  • 7

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    2.3 The power wire connection

    Power jack located in left side of the rear panel, next to the power socket, is the power switch,

    under the left of the power socket is the connective screw of protective grounding wire.

    Connect the power wire

    Insert one end of the power wire into AC power socket, and another end connected to AC power.

    Connect the grounding wire

    When the device connects separately to protective ground, it should adopt independent

    grounding way, that is, grounded together with other devices(such as transmission equipment),

    Grounding resistance of Joint Ground is less than 1.

    CautionBefore connecting the power wire, encoder power switch must be placed in OFFposition, and required grounded together with the power supply system.

    Signal wire connection include connection of output and input signal wire, signal wire of input

    HDMI high-definition connected with HDMI high-definition interface of encoder, the other end

    connect with the output interface of the front-end source equipment. The encoder has 1GE

    port(IP signal input/output network port), it can connected to the device of transmission network

    with network wire.

    Encoder parameters are set by the network interface device operation. Therefore encoder device

    must be connected via 100M Ethernet switch with the computer.

    2.4 Input, output signal wire connection

    2.5 Connecting the encoder communications network management port

    Chapter 3 Operation Guide

    8 in1 full function HD encoder adopt embedded WEB Service, in computer multiple

    browser(support IE browser, Firefox browser, google browser etc.)interface, set each parameter,

    system maintenance and upgrade set, the default setting of device can be used before the

    normal business, also can modify or reconfigured the device parameter settings.

    Enter the WEB interface of the device3.1

    After connected, turn on the power of the all device, select any browser on computer, such as IE

    browser, Google, Firefox browser, enter in the browser address bar: //101.101.101.20/,(Note: the

    default IP address is 20), click the search button to enter the following interface.

  • 8

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure 1 WEB interface

    Enter the Home page interface of network management 3.2

    In figure 1 interface, type admin in the user name bar box and type 12345 in the pass word

    bar box, click on login button to enter the network equipment home interface, As shown in figure

    2 below

    Figure 2 Home Interface

  • 9

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!3.3 Enter into device network management condition monitoring interface

    In figure 2 interface,click on the top row of "Monitor" (condition monitoring) key to enter the device

    network "condition monitoring" screen. Respectively display reads 1, "ASI Output Status" (ASI

    output rate), 2, "ASI Input Status" (input rate), 3, "IP Output Status" (IP output rate), 4 "alarm

    "(alarm), 5," Encoder Status "(coded channel condition monitoring, normal green LED is lit, not

    normal green LED does not light) 5 group, the English state monitoring information, as shown in

    figure 3 below

    Figure 3 ASI output"condition monitoring" network management interface

    Figure 4 English ASI input"Condition Monitoring" network management interface

  • 10

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure 5 English IP output"condition monitoring" network management interface

    Figure 6 English alarm"condition monitoring" network management interface

  • 11

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure7 English encoding channel "condition monitoring" network management interface

    3.4 NMS device "Input Output Settings" interface to enter

    In Figure 2 interface, click on the top row of "Input / Output" key to enter the device network

    "input-output" setting interface. Click on the left top of the "Input / Output Settings" input,

    output setting keys appear: "Input Settings", "Output Settings". Click on each "Input

    Settings" button, "Output Settings" button. Enter respectively the "Encode Settings", "ASI

    Output Sett ings" and "IP Output Sett ings" IP network interface output sett ings.

    3.4.1"Input Settings"(encoding parameter settings):There are five content

    1.Video Input Informationincluding video input Channel Video Input Resolutionvideo input

    resolution TwoWhen encoding the input source is not inserted into the video, input information

    will not be displayed

    2.Primary Video Encode Settingincluding Encode FormatVideo GOPCBR/VBR

    Dynamic Bite rate MaxVideo Average BitrateDynamic Biterate Min 6.

    3.Audio Input Settings including Audio Sample Rate1.

    4.Primary Audio Settings including Audio FormatsSound ModeAudio Bit Rate 3.

    5.System Settings including Primary Stream enable 1. Enter Input Settingsencoding parameter

    settingsChinese and English network interface as shown in Figure 8. The below figure is the

    diagram of the encoding channel 1. 8 encoding channel encoding settings management

    interfaces are the same needing set.

  • 12

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure8 Input setting "encoding setting" network management interface

    3.4.2 ASI Output Settings

    EnterASI Output Settingsnetwork interface1UnderOutput Bitratecan be set

    150Mbps output bitratedetermined in accordance with specific needs2InEnable

    according to the needsselectONthere is stream outputor selectOFFthere is no

    stream outputASI Output SettingsChinese and English network management interface as shown in Figure 9

    Figure 9 English ASI output setting network management interface

  • 13

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!3.4.3 IP Output Settings:Here are two content as below

    1.General Settingsincludes 5 type of "Lcal IP"Lcal MAC Lcal Port Work

    ModeOutput Type

    2.Output Settingsincludes 4 type of Dest IP Dest Port Dest MAC

    Enable.

    IP Output Settings TS over IP module settingsnetwork management interface as shown in Figre10.

    Figure10 IP output settingTS over IP module settingsnetwork management interface

    Enter device network managementMux settingsinterface3.5

    In Figure 2 interface, click on the top row Mux Settings button to enter the device network

    management Mux Settings interface. Click on the top left of Mux Settings button may

    appear two main itemsInput Program InfoOutput Program Editclick on

    eachInput Program InfobuttonOutput Program Editbutton. Enter respectively

    Encode Input InformationsASI Input InformationsNIT EditASI Output Edit

    IP Output Edit 5 small items network management interface.3.5.1 Input Program Info under the main Encode Input Informations interface

    ClickInput Program Infobutton will appearEncode Input InformationsASI Input

    Informations 2 small items. ClickEncode Input Informations button to enter the encoding

    channel Mux settings network management interface.

  • 14

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Encoding channel Mux setting network management interface has two main functions: 1 set

    whereabouts encoding channels program, select 002 multiplex to IP output channels, select OFF,

    not to be multiplexed output. 2 display encoding channels detailed program information, such

    as TS ID, original network IDPMT PIDPCR PIDelementary stream video PID

    elementary stream video PIDPAT\CAT\SDT versionconditional access system(EMM)program type and the program providers information. And this information can only be viewed.

    Please go to the output program main item when need to modify the program.

    There are eight encoding channels, each channel has the same Mux setting network

    management interface,1 encoding channel Mux setting network management interface as shown

    figure 11.

    Figure 11 Encoding channel Mux setting network management interface

    3.5.2 Input Program Info under the main item ASI Input Informationsinterface

    Click on "Input Program Info" button, it will appear "Encode Input Information", "ASI

    Input Information" 2 small items. Click on "ASI Input Information" button to enter the ASI input

    channels Mux settings network interface.

    ASI input channel Mux setting network interface has two main functions: 1detailed ASI input

    channels information after searching all programs, such as TS ID, original network ID, PMT PID,

    PCR PID, the elementary stream video PID, basic streaming audio PID, PAT / CAT / SDT

    version, conditional Access System (EMM), program type, program providers information. The

    provided information can only be viewed, when it needs to modify the program, please enter the

    output program editing main item.

    2After searching all the details on the program displayed in the search based on ASI input

    channels , set the whereabouts ASI inputs of all programs, select 001 is multiplexed to ASI output

    channel, select 002 is multiplexed to IP output channels, when you select OFF, is not to be

    multiplexed output.

    ASI input channels Mux setting network management interface as shown in Figure 12.

  • 15

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure 12 ASI input channels Mux setting network management interface

    3.5.3 "Output Program Edit" under the main item "NIT Edit" NIT editing interface

    Click on "Output Program Edit" button. Enter Respectively "NIT Edit" "ASI Output Edit" ,

    "IP Output Edit" 3 small items network management interface.

    Click on "NIT Edit" button, you can enter the "Network information Edit" NIT table network

    interface.

    The NIT editor NMS interface has three main functions: 1 add directly, " Network ID, " Network

    Name", " NIT version number" , NIT replace selection switch (ASI input stream NIT or self-edited

    NIT) . 2 In the NIT description box may edit(currently only add DVB-C system, could be

    upgraded later) TS ID, ON ID, frequency, modulation mode, symbol rate, FEC lnner, FEC outer7

    items content, each NIT editor Upon completion, the hook inside the small box behind already

    exist, such as the need NIT delete a message, click on the hook behind the small box inside it,

    and click "Submit" to delete. 3, support program reuse and may choose to delete a set of

    program (input program choices after reuse has box here, such as the need to remove the set of

    programs, click the check, become effective after submission). 4, click the drop-down list on

    each program can be edited detailed information of each program, here both ASI input channel

    and coding input channels are the same.

  • 16

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure 13 NIT table edit network management interface

    3.5.4 Output Program Editthe main item ASI Output Editinterface

    Click onOutput Program EditbuttonEnter respectively NIT EditASI Output Edit

    IP Output Edit 3 small item network management interface

    Click onASI Output Editbuttonyou can enterASI Output Editnetwork management

    interface.

    ASI output Edit network interface has four main functions:1 supports the display of TS ID,

    original network ID, PAT, CAI, SDT version number and table interval(in milliseconds), TDT, TOT

    meter interval(in milliseconds), the local conditional access system, multiplexing conditional

    access system(EMM). 2Support selection users private description edit. 3Support program

    multiplexing and can choose to remove one program(program input after selection multiplexing

    tick here already, such as the need to remove this program, click on his hook, the entry into force

    after submit). 4Click on the drop down list on each program details information can be edited,

    Here both ASI input channel and encoding input channels are the same.

    ASI output edit network management interface as shown in Figure 14

  • 17

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    Figure 14 ASI output Edit network management interface

    3.5.5 Output Program Edit the main item IP Output Edit interface

    Click onOutput Program Editbutton, Enter respectively NIT EditASI Output Edit

    IP Output Edit 3 small item network management interface.

    Click onIP Output Edit buttonyou can enter IP Output Edit network management

    interface.

    IP Output Edit network management interface main function is the same with ASI output edit

    network management interface. Refer to ASI output Edit network management interface main

    function.

    IP output edit network management interface as shown in Figure 15

    Figure 15 IP output Edit network management interface

  • 18

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    3.6 Device network managementdevice managementinterface to

    In figure 2 interface, click on the top rowDevice managementto enter the device management button to appear four small item network management interface: System

    SettingsDevice Restore Factory SettingsDevice Network Parameters EditUser

    Management.Enter respectively to System SettingsDevice Restore Factory Settings

    Device Network Parameters EditUser Management four small item network management interface.

    3.6.1 System SettingsinterfaceClick on System Settingswill appear System Settingsnetwork management interface.

    System setting network interface main functions as below:1the date/time of acquisition and

    submit .2parameter guide in/guide out. 3system upgrade.System setting network management interface as shown in Figure 16.

    Figure 16 System setting network management interface

  • 19

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    3.6.2 Device Restore Factory Settings

    Click on Device Restore Factory Settingswill appear Device Restore Factory Settings network

    management interface.

    Device Restore Factory Settingsnetwork management interface main function is to restore the

    factory setting. When you find the device is not working in normal, if you do not know to configure

    the device, please be careful with this option.

    Device Restore Factory Settings network management interface as shown in Figure 17

    Figure17 Device restore factory settings network management interface

    3.6.3 Device Network Parameter Edit

    Click onDevice Network Parameter Editit will appear Device Network Params Edit network

    management interface.

    Device Network Parameter Edit modify network management main function, display and

    modify network IP address, gateway address, sub network mask, MAC address.

    Device network parameters network management interface as shown in Figure 18

    Figure17 Device restore factory settings network management interface

  • 20

    8 IN 1 FULL FUNCTION HD ENCODER Your Best Choice!Your Best Choice!

    3.6.4 User Management

    Click on User Management,there will be User Management network management interface

    User Management network management main function is to manage and modify user name

    password .

    User Management network management interface as shown in Figure 19.

    1.Please read this introduction carefully before use the equipment.

    2.Note: when install the equipment, remember to correctly connect the protective grounding

    cable first. After connect other signal cables, power off the equipment, then plug the outlet cable.

    3.Note In order to ensure the equipment running stably, Do cut off the power before any

    change of cable connection on the ports of back panel.

    4.Make sure the working environment is under temperature 0-45C and other required

    conditions. Keep the back panel ventilated. Make sure all the connections are correct of the

    relative ports.

    5.When initial use, make sure the A/V source is connected normally.

    6.Do not open the lid to avoid electrical shock or damage of the unit.

    7.Do not turn on and off the equipment too often, the time interval between on and off should be

    at least 20 seconds.

    8.If the equipment would not be in use for long time, please unplug the power cord. Do not use

    damaged power in case of fire or electric shock.

    9.Do not touch the power line with wet hands. When any liquid flows into the chassis, cut power

    off IMMEDIATELY.

    10.Put the equipment in a horizontal place. Do not stack heavy objects on the equipment to

    prevent damage.

    11.Settle the equipment in ventilated environment and suitable temperature. Keep the equipment

    away from the fierce light, moisture and severe vibration.

    12.If the working environment has sharp temperature difference as previous, please keep the

    equipment off for one or two hours before power on again.

    13.Between the machine power switch and power socket with fuse holder, When the machine

    power overload or short circuit, the fuse tube disconnected, exchangeable with Specifications of

    the new fuse tube. Remove the fuse tube block method: unplug the power plug with a

    screwdriver inserted into the fuse holder gaps can skip the fuse tube block. New machine fuse

    header contains two fuse tube, one of which is as a backup, damaged the fuse tube can be

    removed, change another backup fuse tube, then the fuse tube to insert the original location.

    The Musts of Safety

    HomeChapter1 Product introduction1.1 Overview1.2 Functions1.3 Technical indicators1.4 Appearance and Description

    Chapter2 Installation guide2.1 Acquisition Check2.2 Installation Preparation2.3 The power wire connection2.4 Input output signal wire connection2.5 Connecting the encoder communications network management port

    Chapter3 Operation Guide3.1 Enter the WEB interface of the device3.2 Enter the Home page interface of network management3.3 Enter into device network management"condition monitoring"interface3.4 NM Sdevice "Input Output Settings"interface to enter3.5 Enter device network management"Mux settings"intergace3.6 Device network management"device management"interface to

    The Musts of Safety