keeping contamination under control.nefilter.com/documents/descase - product catalog.pdf ·...
TRANSCRIPT
Keeping contamination under control.®
TM
Why do the world’s leading companies, distributors, and OEMs look to Des-Case? Because we understand the importance of fluid cleanliness and the role it plays in increased production, cost savings, and reliability. We’ve spent more than 25 years pioneering solutions specific to customer needs, helping improve lubricant quality, and maximizing equipment dependability.
Our comprehensive water and particulate contamination control products are used by hundreds of the world’s top companies for a wide range of applications including gearboxes, reservoirs, and storage/process tanks.
From the time oil enters your facility to the end of its life, protecting it with Des-Case solutions will extend the life of your machinery, decrease your downtime, and could save you hundreds of thousands of dollars. Our innovative contamination control technology consists of rugged, high quality materials that are cost effective for nearly every application.
Pioneers in contamination control.
An imperative link in the reliability chain, Des-Case helps you effectively control contamination before it controls you.
TM
Table of Contents
The Importance of Contamination Control
BreathersOverviewStandard Disposable BreathersHybrid Breathers
• Hydroguard• Ventguard
ExtremeDutyBreathers RebuildableSteelBreathers
• RebuildKitsNon-Desiccant Breathers
• DC-ND-35• DC-ND-2
CustomizedDesiccantBreathers Breather Accessories & Adapters
Fluid Handling ProductsOverview Portable Filtration
• FilterCart• Top-OffTankKits• DrumFilterCart• TCSeriesFilterCart• DrumTopper
Dedicated Filtration • TCSeriesT-Stand• PanelUnit• MobileEquipmentEngineKits• MobileEquipmentHydraulicKits
LubricantStorage&Filtration • LubricantManagementSystem• LTSeriesLubricantManagementSystem
AdapterKits Filter Elements
Oil Sampling Hardware
Lubrication TransformationSM Services
Des-Case offers a full line of adaptable contamination control products.
Make us your definitive solution.
Count on the performance of your industrial equipment.
With increases in the cost of oil, greater desire to minimize usage and waste, and a compelling business case for prolonging equipment life, the economic and environmental reason for controlling contamination of lubricants – from the time oil enters a facility until it leaves – is stronger than ever.Maintaining clean oil is one of the best investments a company can make to keep equipment up and running, yet contamination often remains an overlooked factor behind premature machinery failure and diminished lubricant life.
Reduced downtime, less oil usage, and lower repair and recycling costs all add up to significant savings when solid reliability practices are in place.
Two Major Sources of Lubricant Contamination
DirtIf the atmosphere is contaminated, oil will become dirtier and lubricant quality becomes compromised. Particulate contamination, once inside an operating system, will accelerate the generation of new contaminants. These contaminants damage critical components and act as a catalyst for oxidation, further degrading the condition of lubricants.
WaterIf the atmosphere is particularly humid or has frequent temperature fluctuations, the oil is probably moisture-laden and lubricant quality is compromised. Often times, plant wash down activities are responsible for inducing conditions that lead to moisture ingression and corrosion.
Contamination Control is Important
Des-Case products & services are the solution.
Des-Case products and services are designed to help companies achieve a new level of performance in maintenance and reliability. Combining unique services, a wide array of products, and solid support, Des-Case can help increase uptime, reduce costs, and gain greater efficiencies for your equipment.
DetectionMost people recognize that precision is an important part of a reliabilitydriven maintenance program, but often struggle with how and where to startimplementing changes. Des-Case’s Lubrication TransformationSM Servicesare designed to help companies develop and deploy an executable plan tohelp them get to the next level. The Lubrication TransformationSM process can help you quickly identify the steps you need to take, help your team learn practical machinery lubrication, and perform cost-benefit analysis to assist you in your implementation.
PreventionGetting clean, dry oil into machines (and keeping it that way) is one of themost fundamental elements of precision lubrication. Des-Case’s lines ofdesiccant breathers, lubricant storage systems and oil transfer and filtrationsystems help plants meet or exceed the stringent contamination controltargets necessary to achieve improved machine reliability and productionuptime.
RemovalFiltration devices should be used to remove particles and water, furtherextending and preserving the working life of the oil. They are not just a tool foremergency remedial measures when dealing with contaminated lubricants andhydraulic fluids, but are an integral component of proactive maintenance. Des-Case provides a wide array of customizable, quality filtration units, from small,portable devices to full-featured storage and vacuum dehydration systems.
The Bottom LineNow, implementing lubrication best practices – including maintaining clean, dry lubricants—and gaining theprofitability that goes with it, is easier than ever. Des-Case’s technical team can help you evaluate where you are, giveyou guidance on where to go, and provide the tools to get you there.
Contamination Control is Important
LubricationTransformation SM
Breathers: thefirstlineofdefenseagainstcontamination
Breathers: Overview
Installation of Des-Case® breathers at critical ingression points is a cost-effective means to prevent contaminants from entering the fluid reservoirs as differential pressures occur.
Reverse flow through the breather allows for regeneration of the desiccant and prevents oil vapors from entering the work environment.
Desiccant breathers are a vital step in contamination control.Studieshaveshown50to70percentoflubricantcontaminationcancomefromoutsidetheequipment.Asmostmachinesaredesignedto“breathe”,protectingthesourceofair-flowfrommoistureandparticulatecontamination is extremely
valuableforfront-endprotectionandreliabilityoptimization.
Des-Casedesiccantbreathersincorporateahighcapture-efficiencyfiltertohelpsustaindesiredcleanlinesslevelsbyremovingevenminuteparticulatematter.Theyalsocreatelowrelativehumiditylevelsintheheadspace,makingcondensationandabsorptionbythelubricantunlikely.Whenasystemisproperlyfittedwithabreathercontaining dryingandfiltrationmedia,contaminantingressionisgreatlyreduced.
Customizable Desiccant Breathers
Environment
Standard Disposable Breathers
Environment
Extreme Duty Breathers
Environment
Non-Desiccant Breathers
Environment
Hyrbrid Breathers Environment
Rebuildable Steel Breathers
Environment
Breathers: Overview
Breather Products
Des-Case invented the desiccant breather and continues to invent new solutions to keep moisture and contaminants out of an increasingly valuable asset – your oil.
• Intermittent operations• Transformers• StorageTanks• Totes• Hydraulics
• Harsh environments• Mobileequipment• Nauticalapplications
• Gearboxes and otherlow-flowapplications
• High-humidityapplications
• Lowhumidityapplications
• Arid,highdustenvironments
• Applications that create“oilmisting”
• Hydraulicreservoir• Bulkoilstorage• Dieseltankstorage• Chemical/harsh
environments• High-flowapplications
• Intermittent operations• Transformers• StorageTanks• Totes• Fumes
Bre
athe
rs
Standard Disposable Breathers
EveryelementofDes-Case’sStandardDisposableBreathershavebeendesignedtoworkinawidevarietyofindustriesandapplications.Thebreather’sresilient,integratednylonstandpipeensuresthatitcaneasilycombathighvibrationandvolatileenvironments.Eachbreatherisoutfittedwithaclear,ruggedpolycarbonatecasingthatallowseasyviewofcolor-indicatingdesiccantinordertomonitorwhenthebreathershouldbereplaced.
Withover25yearsofcontaminationcontrolexpertise,Des-Casebreathersattackthesourceofcontamination,makingtheproductsanaffordableandcosteffectivesolutiontoextendlubricantlifeandtoincreaseequipmentproductivity.
Breathers: Standard Disposable Breathers
Environments • Intermittent operations
• Transformers
• StorageTanks
• Totes
• Hydraulics
How it Works
Breathers: Standard Disposable Breathers
As wet contaminated air isdrawnthroughtheunit,multiple3-micronpolyesterfilter elements remove solid particulateandthecolor-indicatingsilicagelextractsmoisture.
Whenairisexpelledfromthecontainer,thetopfoampadpreventsoilmistfromcontactingthesilicagelorenteringtheatmosphere.
Resilient Polycarbonate BodyShock-absorbing,clearcasingprovides reliable service and
easy maintenance.Filter ElementPatentedpolyesterfilterelementremoves airborne contamination to 3-micronabsolute.Uniqueloopsallowparticlestoreleaseduringsystemexhalation,helpingtoincreasebreatherlife.
Threaded MountingEasily replaces standard
filler/breathercapwithoneofseveraladapters.
Air VentsIndividualairintakesareopenedbasedontheflowrequirementsofthesystem.Ratedfor16cfm.Plugskeepunitinactiveuntiluse.
Water Vapor AdsorbentSilicagelabsorbswaterfromincomingair.Indicatesconditionbychangeofcolorfrombluetopink.
Filter ElementSecondpolyesterfilterelementprotectsagainstanymigration
ofdesiccantdust,providingmaximumefficiency.
Foam PadCapturesanyoilmistand
dispersesincomingairevenlyoverfiltrationand
dryingareas.
Foam PadReducesoilmistthatcontactssilicagelduringexhalationandensuresoutgoingairisevenlydisbursedthroughthefiltersanddesiccant.
Product Specifications DC-BB DC-1 DC-2 DC-3 DC-4UnitHeight(in/mm) 3.90˝/99.06mm 5.31˝/134.9mm 6.125˝/155.6mm 8.125˝/206.4mm 10.125˝/257.2mm
UnitDiameter(widthin/mm) 2.52˝/64.01mm 2.52˝/64.01mm 4˝/101.6mm 4˝/101.6mm 4˝/101.6mm
ShippingWeight(unit/case)(lbs/kg) 0.31lbs/2.14lb0.14kg/0.97kg
0.51lbs/3.32lbs0.23kg/1.51kg
1.21lbs./7.73lbs 0.55kg/3.51kg
1.87lbs./11.74lbs. 0.85kg/5.32kg
2.63lbs./16.13lbs 1.2kg/7.33kg
AmountofDesiccant 0.13lbs/58.6g 0.28lbs/125.3g 0.66lbs/0.30kg 1.22lbs./0.56kg 1.88lbs./0.84kg
Max.AdsorptionCapacity(floz/ml) 0.79floz/23.3ml 1.68floz/49.7ml 4fl.oz./118.2mL 7.45fl.oz/220.3mL
11.3fl.oz./333mL
Max.FlowRate(cfm) 4.55 @ 1 psid 4.16 @ 1 psid 16 @ 1 psid 16 @ 1 psid 16 @ 1 psid
Max.FlowRate(lpm) 128.84 117.8 453 453 453
Filtration 3µabsolute(β3≥ 200)
3µabsolute(β3≥ 200)
3µabsolute(β3≥ 200)
3µabsolute(β3≥ 200)
3µabsolute(β3≥ 200)
OperatingTemp.Range(°F) -20ºF to 200ºF -20ºF to 200ºF -20ºF to 200ºF -20ºF to 200ºF -20ºF to 200ºF
OperatingTemp.Range(°C) -29ºCto93ºC -29ºCto93ºC -29ºCto93ºC -29ºCto93ºC -29ºCto93ºC
HydrophilicAgent Silicagel Silicagel Silicagel Silicagel Silicagel
FilterMedia Polyester Polyester Polyester Polyester Polyester
ConnectionSize 3/8˝Multi-Fit(NPT,BSPP,BSPT)
3/8˝Multi-Fit(NPT,BSPP,BSPT)
1˝Multi-Fit(NPT,BSPT,NPSM)
1˝Multi-Fit(NPT,BSPT,NPSM)
1˝Multi-Fit(NPT,BSPT,NPSM)
BodyMaterial Polycarbonate,Nylon,Polypropylene,Polyester,Polyurethane,Silica,Buna-N,PVC
Bre
athe
rs
Hydroguard™ Hybrid Breathers
Fromtheexpansionchambersystemtothecheckvalves,Des-CaseHydroguard™hybridbreathersareinnovativelydesignedtoperforminmanydifferentenvironments.
Thebreatherisoutfittedwithanexpansionchambertoisolatelubricantsfromalllevelsofambienthumidity.Aclear,ruggedpolycarbonatecasingallowsforviewingdesiccantasitchangescolor,indicatingthatthebreathershouldbereplaced.Checkvalvesensurenoexcesspressure/vacuumbuilds.
Des-Casehybridbreathersattackthesourceofcontamination,allowingyourequipmentandlubricantstorunlongerandharder.
Breathers: Hybrid Breathers
Environments • Gearboxes and otherlow-flowapplications
• High-humidityapplications
How it Works
Breathers: Hybrid Breathers
Aswet,contaminatedairisdrawnthroughtheunit,multiple3-micronpolyesterfilterelementsremovesolidparticulateandthecolor-indicatingsilicagelextractsmoisture.
Thediaphragmallowsforexpansion/contractionoftheairwithinthecasingasaresultoftemperaturevariationsduringsteady-stateoperations.
Whenairisexpelledfromthecontainer,thetopfoampadpreventsoilmistfromcontactingsilicagelorenteringtheatmosphere.Thehydrophilicagentispartiallyreactivatedbythedryairpassingbackthrough.
Product Specifications DC-HG-1 DC-HG-8
UnitHeight 7.22˝/183mm 9.75˝/247.6mm
UnitDiameter 2.52˝/64mm 4.1˝/104.1mm
ShippingWeight(unit/case) 0.58lbs./3.75lbs. 0.26kg/1.7kg
1.81lbs./11lbs. 0.82kg/4.92kg
AmountofDesiccant 0.28lbs./125.1g 0.65lbs./0.24kg
Max.AdsorptionCapacity(fl.oz./mL)
1.68fl.oz./49.6mL 4.05fl.oz./120mL
Max.FlowRate (cfm) 1.41 @ 1 psid 2.5 @ 1 psid
(lpm) 39.93 70.5
Filtration 3μabsolute(β3≥200)
3μabsolute(β3≥200)
OperatingTemp.Range -20°F to 200°F/ -29°Cto93°C
-20°F to 200°F/ -29°Cto93°C
HydrophilicAgent Silicagel Silicagel
FilterMedia Polyester Polyester
ConnectionSize 3/8˝Multi-fit(NPT,BSPP,BSPT)
1˝Multi-fit(NPT,NPSM,BSPT)
ExpansionChamberVolume
1.935in3 15.66 in3
BodyMaterial Polycarbonate, Nylon, Polypropylene, Polyester, Polyurethane,Buna-N,PVC
Threaded MountingEasily replaces standardfiller/
breather cap with one ofseveraladapter
options.
Water Vapor AdsorbentSilicagelabsorbs water fromincomingair. Indicates condition by changeofcolorfrombluetopink.
Filter ElementSecond
polyester filterelement
protects againstanymigrationof
desiccant.
Interior Check Valves
Provides system isolation when inactive,
protectingsystemintegrity.
Foam PadReducesoil mist exhalation. Ensuresoutgoingair is evenly disbursedthroughthefiltersanddesiccant, providingmaximumefficiency.
Expansion Chamber
Thediaphragmallowsfor
expansion/contractionof
the air within the casingasaresult
oftemperaturevariationsduring
steady-state operations.
Filter ElementPatented polyester filterelementremoves airborne contamination to 3-micronabsoluteUniqueloopsallowparticles to release duringsystemexhalation,helpingto increase breather life.
Resilient Polycarbonate
BodyShock-
absorbing,clearcasing
provides reliable service
and easy maintenance.
Bre
athe
rs
Ventguard™ Hybrid Breathers
VentGuard™hybridbreathersvirtuallyisolateequipmentfromsurroundingparticulatecontamination.
Thebreatherisoutfittedwithcheckvalvestoensurenoexcesspressure/vacuumbuilds.Aclear,ruggedpolycarbonatecasingallowsforviewingdesiccantasitchangescolor,indicatingthatthebreathershouldbereplaced.
Des-Casehybridbreathersprotectlubricantandequipmentfromcontaminationthatcanleadtoproductiondowntimeandcostlyequipmentrepairs.
Breathers: Hybrid Breathers
Environments • Gearboxes and otherlow-flowapplications
• High-humidityapplications
Resilient Polycarbonate
BodyShock-
absorbing,clearcasing
provides reliable service
and easy maintenance.
Filter ElementPatented polyester
filterelementremoves airborne
contamination to 3-micronabsolute.
Uniqueloopsallow particles
to release duringsystem
exhalation, helpingto
increase breatherlife.
Threaded Mounting
Easily replaces standardfiller/
breather cap with oneofseveral
adapters options.
Water Vapor AdsorbentSilicagelabsorbs water fromincomingair. Indicates condition by changeofcolorfrombluetopink.
Filter ElementPolyester
filterelementprotectsagainst
anymigrationofdesiccant
providingmaximumefficiency.
Foam PadReducesoilmistthatcontactssilicagelduringexhalationandensuresoutgoingairisevenlydisbursedthroughthefiltersanddesiccant.
Interior Check ValvesProvides system isolation when inactive,protectingsystemintegrity.
How it Works
Breathers: Hybrid Breathers
As wet, contaminated air is drawnthroughtheunit,multiple3-micronpolyesterfilterelementsremovesolidparticulateandthecolor-indicatingsilicagelextractsmoisture.
Whenairisexpelledfromthecontainer,thetopfoampadpreventsoilmistfromcontactingsilicagelorenteringtheatmosphere.
Thebreatherisoutfittedwitharesilient nylon standpipe and a clear polycarbonate body which allowsforeasymonitoringofthehigh-contrastsilicagel.
Product Specifications DC-VG-BB DC-VG-1 DC-VG-2 DC-VG-3 DC-VG-4UnitHeight 3.9˝/99.06mm 5.31˝/135mm 6.125˝/155.6mm 8.125˝/206.4mm 10.125˝/257.2mm
UnitDiameter 2.52˝/64.01mm 2.52˝/64mm 4˝/101.6mm 4˝/101.6mm 4˝/101.6mm
ShippingWeight(unit/case) 0.31lbs./2.14lbs 0.14kg/0.97kg
0.52lbs./3.37lbs. 0.24kg/1.53kg
1.21lbs./7.73lbs 0.55kg/3.51kg
1.87lbs./11.74lbs. 0.85kg/5.32kg
2.63lbs./16.13lbs 1.2kg/7.33kg
AmountofDesiccant 0.13lbs./58.6g 0.28 lbs. /125.1g
0.66lbs/0.30kg 1.22lbs./0.56kg 1.88lbs./0.84kg
Max.AdsorptionCapacity 0.79fl.oz./23.3mL 1.68fl.oz. /49.6mL
4fl.oz./118.2mL 7.45fl.oz/220.3mL 11.3fl.oz./333mL
Max.FlowRate (cfm) 1.45 @ 1 psid 1.45 @ 1 psid 2.5 @ 1 psid 2.28 @ 1 psid 1.8 @ 1 psid
(lpm) 41.06 41.06 70.5 64.5 50.9
Filtration 3µabsolute(β3 ≥200) 3µabsolute(β3 ≥200) 3µabsolute(β3 ≥200) 3µabsolute(β3 ≥200) 3µabsolute(β3 ≥ 200)
OperatingTemp.Range -20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
HydrophilicAgent Silicagel Silicagel Silicagel Silicagel Silicagel
FilterMedia Polyester Polyester Polyester Polyester Polyester
ConnectionSize 3/8˝Multi-fit(NPT,BSPP,BSPT)
3/8˝Multi-fit(NPT,BSPP,BSPT)
1˝Mult-fit(NPT,BSPT,NPSM)
1˝Mult-fit(NPT,BSPT,NPSM)
1˝Multi-fit(NPT,BSPT,NPSM)
BodyMaterial Polycarbonate,Nylon,Polypropylene,Polyester,Polyurethane,Buna-N,PVC
Bre
athe
rs
Extreme Duty Breathers
Breathers: Extreme Duty Breathers
Environments • Harsh environments
• Mobileequipment
• Nauticalapplications
ExtremeDutyBreathersaredesignedtotakecontaminationcontroltoanentirelynewleveloflubricantprotection.
Thebreatherisoutfittedwitharuggedhousingandanintegratedstandpipe,allowingfordecreasedoilmistingwhileofferingimprovedvibrationresistance.Visualindicatorwindowsshowthedesiccantasitchangescolor,indicatingthatthebreathershouldbereplaced.Checkvalveskeepoutambienthumiditywhilethe system is at rest.
Anidealsolutionforavarietyofbothstationaryandmobileequipmentapplications,Des-Case’sExtremeDutyBreathercancombatthemostunforgivingmanufacturingenvironment.
How it Works
Breathers: Extreme Duty Breathers
Aswet,contaminatedairisdrawnthroughtheunit,multiple0.3micronfilterelementsremovesolidparticulateandthecolor-indicatingsilicagelextractsmoisture.Whenairisexpelledfromthecontainer,thetopfoampadpreventsoilmistfromcontactingsilicagelorenteringtheatmosphere.Thehydrophilicagentispartiallyreactivatedbythedryairpassingbackthrough.
Foam PadCapturesanyoilmistanddispersesincomingairevenlyoverfiltrationanddryingareas.
Water Vapor Adsorbent
Colorindicatingsilicageladsorbs
waterfromincomingair.
Replace when colorchanges
frombluetopink.
Filter ElementSecond particulatefilterelementprotects againstmigrationofdesiccant.
Foam PadFoamfilterreduces
oilmistduringexhalation, evenly
distributesair
Visual Indicator Windows on two sidesofbreatherallowforeasymonitoringofdesiccant.
Filter Element Removes airborne
contamination to0.3-micron
absolute.Stopsfree
water.
Quad Check Valves
Provides system pressurization,
protectingsystemintegrityand
extending productlife.
Rugged HousingConstructedfromapolycarbonate/polybutylteraphtalate(PC/PBT)alloy.Themoldingprocessdis-tributesthematerialstomaximizechemicalcompatibility at the surfaceandimpactresistance at the core.
Extreme Duty Breather AdaptersAdapterPartNumber Description ApplicationConnection
Type/SizeNumber
DC-DSA-17 ConnectsExtremeDutyBreathertoa1½˝x16UNmalethreadedconnection. 3/4˝ThreadedFemale
DC-DSA-10 ConnectsExtremeDutyBreathertoa1½˝x16UNmalethreadedconnection. 1˝ThreadedFemale
DC-XDVA-12M VentValveAdapterconnectsExtremeDutyBreathertoa1½˝x16UNmalethreaded connection.
3/4˝ThreadedFemale
DC-XDVA-16M VentValveAdapterconnectsExtremeDutyBreathertoa1½˝x16UNmalethreaded connection.
1 ̋ThreadedFemale
Product Specifications DC-XD-6
UnitHeight 6.51˝/165.4mm
UnitDiameter 5.1˝/129.5mm
ShippingWeight(unit/case)
3.03lbs./19.97lbs. 1.37kg/9.06kg
AmountofDesiccant 1.75lbs./0.79kg
Max.AdsorptionCapacity 10.65fl.oz./315mL
Max.FlowRate
(cfm) 16 @ 1 psid
(lpm) 456
Filtration 0.3µabsolute(β0.3≥200)
OperatingTemp.Range -40ºFto300ºF-40ºCto148.89ºC
HydrophilicAgent Silicagel
FilterMedia ePTFE
ConnectionSize 1½˝x16UNfemalethread
BodyMaterial Polycarbonate/Polybutylteraphtalate(PC/PBT),Polytetrafluoroethylene, Aluminum,Polyurethane,Polycarbonate
Bre
athe
rs
Rebuildable Steel Breathers
Breathers: Rebuildable Steel Breathers
Environments • Hydraulicreservoir
• Bulkoilstorage
• Dieseltankstorage
• Chemical/harshenvironments
• High-flowapplications
Product Specifications
DC-RS-3 DC-RS-5 DC-RS-9 DC-RS-15 DC-RS-25 DC-RS-50 DC-RS-75 DC-RS-100 DC-RS-150 DC-RS-200
Height (in./mm.)
11.5/292 13.75/349 18.25/464 19.25/489 22.5/571 31.25/794 39.75/1010 31/787 36.75/933 42.75/1086
Width (in./mm.)
10.13/257.2 10.13/257.2 10.13/257.2 15.5/393.7 15.5/393.7 15.5/393.7 15.5/393.7 23.5/596.9 23.5/596.9 23.5/596.9
Approx. Dry Weight (lbs/kg)
16/7.26 20/9.07 27/12.25 49/22.23 64/29.03 100/45.36 144/65.32 190/86.18 253/114.76 315/142.88
AmountofDesiccant(lbs./kg)
3/1.36 5/2.27 9/4.08 15/6.80 25/11.34 50/22.68 75/34.02 100/45.36 150/68.04 200/90.72
Max.Adsorp-tionCapacity(gal/L)
0.14/0.54 0.24/0.9 0.43/1.62 0.71/2.7 1.19/4.5 2.38/9 3.57/13.5 4.75/18 7.13/27 9.51/36
Max.Flowrate 85 @ 0.5 psid2407 Lpm
85 @ 0.5 psid2407 Lpm
80 @ 0.5 psid2265 Lpm
205 @ 0.5 psid5805 Lpm
140 @ 0.5 psid3964Lpm
115 @ 0.5 psid3256Lpm
80 @ 0.5 psid2265 Lpm
270 @ 0.5 psid7645 Lpm
250 @ 0.5 psid7079 Lpm
240 @ 0.5 psid6796 Lpm
Max.Operat-ingTemp.
-20to220ºF/-29to104ºC
ConnectionSize(NPT)
2˝ 2˝ 2˝ 3˝ 3˝ 3˝ 3˝ 4˝ 4˝ 4˝
BodyMaterial Carbonsteel,Polyurethane,Polypropylene,Microglass,Polycarbonate,Nomex,Buna-N (Silicagelashydrophilicagent.)
Des-Case recommends use of a pressure/relief valve on any tank or storage system.
Utilizingdesiccantbreatherscanreducethenegativeeffectscausedbycontaminationthatresultinmillionsofdollarsspentannually.Contaminatedlubricantandhydraulicfluidresultinexcessmachinewear,productiondowntime, and repair costs.
Des-Casebreathersreducecontamination,keepingdirtandwaterwhereitbelongs–outofyourequiptment.
Rebuild Kits for Rebuildable Steel Breathers
Breathers: Rebuildable Steel Breathers
Outside Sight Glass indicator
Silicagelchangescolor
frombluetopinkwhentheunitrequirescomponent
replacement(orrebuilding).
Pleated Filter ElementCapturesairborne contamination to 1-micron absolute, (β1≥1,000).
Rugged HousingPowder-coated carbon steel or stainless steel.
Water Vapor AdsorbentClearsilicageladsorbs water fromincomingair.
Foam PadDispersesincomingair evenly over filtrationanddryingarea.
Air VentsRemovableplugskeepbreatherinactiveuntil
installation.
Easy-to-Replace Desiccant BagPolypropylenebaghashandlesforeasyremoval.
Integrated StandpipeResilientconstructionprovidesdurabilityand allows oil mist to coalesce and drain backintoareservoir.
Rebuild Kit Components
Replacement Filter ElementCapturesairbornecontamination to1-micronabsolute.
Desiccant Bag FilterPolypropylenebaghashandlesforeasyremovaland replacement.
Sight Glass IndicatorSilicagelchangescolorfrombluetopinkwhentheunitrequiresrebuilding.
GasketSeals breather at removable lid.
Foam PadDispersesincomingairevenlyoverfiltrationanddryingareas.
Parts and AccessoriesModel # DescriptionDC-RS-X-RK RebuildableSteelBreatherRebuildKits
DC-RS-X-F1 RebuildableSteelBreatherMicroglassFilterElements
DC-RS-X-D1 RebuildableSteelBreatherDesiccantBagSets
DC-RS-X-SG1 RebuildableSteelBreatherSightGlassCartridges
DC-RS-X-P1 RebuildableSteelBreatherFoamPadInserts
DC-RS-X-G1 RebuildableSteelBreatherGasketSeals
* For part codes containing X substitute the appropriate RS model number(Example the part code for a sight glass cartridge for the DC RS 150 would be DC RS 150 SG1 )
Des-Case recommends use of a pressure/relief valve on any tank or storage system.
Rebuild kits can be ordered in a variety of the below materials to meet chemical compatibility needs:
Gasket/Seal MaterialBuna-N(Standard)VitonEPDMSBRRubber
Filter MaterialMicroglass/PolyurethaneFilter(Standard)Microglass/PlastisolFilter
Steel HousingsCarbonSteel(Standard)304StainlessSteel316StainlessSteel
MediaSilicaGel(Standard)ActivatedCarbonMolecularSieveActivatedAlumina
Bre
athe
rs
Hydrophobic Media Hydrophobic media creates a water barrier.
Oil Coalescing
Pleated ElementPleated filter element protectsagainst particulatecontamination.
Threaded MountingEasily replaces standardfiller/breathercap withadapter/reduceroptions.
Rugged ExteriorDurable,shockabsorbinghousing.
Non-Desiccant Breathers: DC-ND-35
Breathers: Non-Desiccant Breathers
Des-CaseNon-DesiccantBreathers,withoilcoalescingfilters,protectequipmentandlubricantfromharmfulcontamination.Contaminatedlubricatingoilandhydraulicfluidresultinexcessmachinewear,productiondowntime,andhigherrepaircosts.
Des-Casenon-desiccantbreathersarebestsuitedforlowhumidityapplications,arid/high-dustenvironments,andapplicationsthatcreateoil“misting”.
How it WorksAswet,contaminatedairisdrawnthroughtheunit,thehydrophobicmediarepelswaterand thepleatedoilcoalescingparticulatefiltercapturescontamination,preventingbothfromenteringtheequipment.
Product Specifications DC-ND-35UnitHeight(in/mm) 5˝/127mmUnitDiameter(widthin/mm) 5˝/127mmShippingWeightDryWeight(unit/case)(lbs/kg)
1lb/6lbs0.45kg/1.38kg
AmountofDesiccant n/aMax.AdsorptionCapacity(gal/l) n/aMax.FlowRate(cfm) 40 @ 1 psidMax.FlowRate(lpm) 1132Filtration 0.3µabsolute(β0.3≥1000)OperatingTemp.Range(°F) -40to300OperatingTemp.Range(°C) -40 to 149HydrophilicAgent n/aFilterMedia ePTFEConnectionSize(NPT) 1˝BodyMaterial Nylon6/6(33%glass
filled),Plastisol,Polytetrafluoroethylene
Benefits• Lowhumidityapplications
• Arid,highdustenvironments
• Applications that create “oilmisting”
Non-Desiccant Breathers: DC-ND-2
Breathers: Non-Desiccant Breathers
Benefits• Lowhumidityapplications
• Arid,highdustenvironments
• Applications that create “oilmisting”
Industryspendsmillionsofdollarsannuallytreatingthenegativeeffectsofcontaminationcausedbywet,dirtyair.Contaminatedlubricatingoilandhydraulicfluidresultinexcessmachinewear,productiondowntime,andrepaircosts.
Actualsize.
Rugged ExteriorDurable,shockabsorbinghousing.
Threaded MountingEasily replaces standard filler/breathercapwithadapter/reduceroptions.
Hydrophobic Filter
ElementParticulatefilterelement repels
water and protects againstdirt.
Product Specifications DC-ND-2UnitHeight 1.35˝/34.3mm
UnitDiameter 1.80˝/45.7mm
ShippingWeightperUnit 0.06lbs./0.026kg
AmountofDesiccant n/a
Max.AdsorptionCapacity n/a
Max.FlowRate (cfm) 0.67 @ 1 psid
(lpm) 19
Filtration 0.3µabsolute(β0.3 ≥1000)
OperatingTemp.Range -40ºFto300ºF/-40ºCto149ºC
HydrophilicAgent n/a
FilterMedia ePTFE
ConnectionSize(NPT) 3/8˝
BodyMaterial Nylon6/6(33%glass-filled)
Des-Casenon-desiccantbreathersarebestsuitedforlowhumidityapplications,continuousoperationswithfrequentwashdowns,arid/high-dustenvironments,andlow-flowapplications.
Des-Casebreathersattackthesourceofcontamination,allowingyourequipmentandlubricantstorunlongerandharder.
How it WorksAswet,contaminatedairisdrawnthroughtheunit,thehydrophobicmediarepelswaterandtheoilcoalescingparticulatefiltercapturesdirt,preventingbothfromenteringtheequipment.
Bre
athe
rs
Customized Desiccant Breathers
Breathers: Customized Desiccant Breathers
Des-Case’sCustomizedDesiccantBreathershavebeendesignedtoworkinawidevarietyofindustries.Des-Caseoffersseveralsecondaryagentmediaoptionsthatpreventfumesandothercontaminantsfromenteringequipment.Themediainsecondaryagentbreatherscanbemixedtomeetspecificenvironmental and chemical needs.
Eachbreatherisoutfittedwithaclear,ruggedpolycarbonatecasingandanintegratednylonstandpipethatprovidesgreaterchemicalcompatibilityandvibration resistance.
Withover25yearsofcontaminationcontrolexpertise,Des-Case’sinnovativebreathersareanaffordableandcosteffectivesolutiontoextendlubricantlifeandincreaseequipmentproductivity.
Customized Desiccant Options Include:
Breathers: Customized Desiccant Breathers
OrangeSilicaGel ActivatedCarbon MolecularSieve ActivatedAlumina Layered (BlueSilicaGel
&MolecularSieve)
Resilient Polycarbonate
BodyShock-absorbing,
clearcasingprovides reliable
service and easy maintenance.
Filter ElementPatentedpolyesterfilterelement removes airborne contaminationto3-micronabsolute.Uniqueloopsallowparticlestoreleaseduringsystemexhalation,helpingtoincreasebreatherlife.
Threaded MountingEasily replaces standardfiller/
breather cap with one ofseveraladapters.
Air VentsIndividualairintakesare opened based on theflowrequirementsofthesystem.Ratedfor16cfm.Plugskeepunitinactiveuntiluse.
Water Vapor AdsorbentSilicagelabsorbswaterfromincomingair.Indicates condition by changeofcolorfrombluetopink.
Activated CarbonSecondary adsorbent filtersadditionalcontaminantsforyourapplication.Canbeaddedin25%ratios.
Filter ElementSecond polyester
filterelementprotectsagainstanymigration
ofdesiccantdust, providingmaximum
efficiency.
Foam PadCapturesanyoil
mist and disperses incomingairevenlyoverfiltrationand
dryingareas.
Foam PadReducesoilmistthatcontactssilicagelduringexhalationandensuresoutgoingairisevenlydisbursedthroughthefiltersand desiccant.
Example: 25% Activated Carbon Breather
Model No. DC-2SBNCXX* DC-3SBNCXX* DC-4SBNCXX*UnitHeight 6.125˝/155.6mm 8.125 ̋/206.4mm 10.125˝/257.2mm
Diameter 4˝/101.6mm 4˝/101.6mm 4˝/101.6mm
ShippingWeight(unit/case)
1.21lbs./7.73lbs 0.55kg/3.51kg
1.87lbs./11.74lbs. 0.85kg/5.32kg
2.63lbs./16.13lbs 1.2kg/7.33kg
AmountofDesiccant
0.66lbs/0.30kg 1.22lbs./0.56kg 1.88lbs./0.84kg
Max.AdsorptionCapacity**
4fl.oz./118.2mL 7.45fl.oz/220.3mL 11.3fl.oz./333mL
Max.Flow Rate
(cfm) 16 @ 1 psid 16 @ 1 psid 16 @ 1 psid
(lpm) 453 453 453
OperatingTemp.Range
-20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
-20ºFto200ºF/-29ºCto93ºC
Hydrophilic Agent
Silica Gel Silica Gel Silica Gel
FilterMedia Polyester Polyester Polyester
ConnectionSize 1˝Multi-Fit(NPT,BSPT,NPSM)
BodyMaterial Polycarbonate,Nylon,Polypropylene,Polyester,Polyurethane, Buna-N,PVC
The above specifications are for a silica gel-only hydrophilic agent breather. Some specifications for a breather containing a secondary agent would change.
* Note:“XX”denotespercentageofsecondaryagent.Forexample,DC-2SBNC25isaDC-2with25%activatedcarbon.
**Sameastheequivalentstandarddesiccantbreatheratmaximum.
Bre
athe
rs
Breather Accessories & Adapters
Breathers: Breather Accessories & Adapters
Des-Case’sbreatheraccessoryandadapterproductsofferanoptimumsolutionforvariousequipmentconnectionneeds.Nomatter the connection type and size,breatheradaptersprovidea sealed system that will protect equipmentfromexternalmoistureandharmfulparticlecontamination.Choosefromavarietyofmaterials,connectionportsize,andthreadrequirementsinordertoproperlyoutfityourequipmentapplication.
Adapters & Accessories
DC-17-TBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)breathersto1”femaleNPTadapter
Equipment Connection Port/Size: 3/4˝FemaleNPT
Breathers: StandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)
DC-13-TBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)breathersto1”femaleNPTadapter
Equipment Connection Port/Size:1̋ MaleNPT
Breathers: StandardDisposable(DC-2,DC-3,DC-4), Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)
DC-35Breather Connection: ConnectsStandardDisposable (DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)breathersto3/8˝femaleNPTadapter
Equipment Connection Port/Size: 3/4˝FemaleNPT
Breathers: Standard Disposable (DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)
DC-36Breather Connection: ConnectsStandardDisposable (DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)breathersto3/8˝femaleNPTadapter
Equipment Connection Port/Size: 1˝FemaleNPT
Breathers: StandardDisposable(DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)
DC-37Breather Connection: ConnectsStandardDisposable (DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)breathersto3/8˝femaleNPTadapter
Equipment Connection Port/Size: 1/2˝FemaleNPT
Breathers: StandardDisposable(DC-BB,DC-1),Ventguard(DC-VG-BB,DC-VG-1),Hydroguard(DC-HG-1)
Bayonet Adapter
DC-15-TBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)breathersto1˝femaleNPTadapter
Equipment Connection Port/Size: 11/2 ̋BayonetStyle
Breathers: StandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8),
Breathers: Breather Accessories & Adapters
Flange Adapter
Vacuum Indicator Adapters
DC-SB-VIBreather Connection: ConnectsNon-DesiccantBreather(DC-ND-35)to1˝maleNPTadapter,withsinglepositionvacuumindicator
Equipment Connection Port/Size: 1˝FemaleNPT
Breathers: Non-DesiccantBreather(DC-ND-35)
DC-OCM5-VIBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)breathersto1˝femaleNPTadapter,withsinglepositionvacuumindicatorandoilcoalescingfiltermedia
Equipment Connection Port/Size: 1˝MaleNPT
Breathers: StandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)
DC-13-T-VIBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)breathersto1˝femaleNPTadapter,withsinglepositionvacuumindicator
Equipment Connection Port/Size: 1˝MaleNPT
Breathers: StandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)
DC-12-TBreather Connection: ConnectsStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard (DC-HG-8)breathersto1˝femaleNPTadapter
Equipment Connection Port/Size: 6boltcircularmounting (Ø3.5˝ )
Breathers: StandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2,DC-VG-3),Hydroguard(DC-HG-8)
Rebuildable Steel Adapters
DC-13-6CBreather Connection: ConnectsRebuildableSteelBreathers(DC-RS-3,DC-RS-5,andDC-RS-9)to2˝femaleNPTadapter
Equipment Connection Port/Size: 4boltcircularmounting(Ø6.0˝ )
Breathers: RebuildableSteelBreathers(DC-RS-3, DC-RS-5,DC-RS-9)
DC-13-10CBreather Connection: ConnectsRebuildableSteelBreathers(DC-RS-15,DC-RS-25,DC-RS-50,and DC-RS-75)to3˝femaleNPTadapter
Equipment Connection Port/Size: 4boltcircularmounting(Ø7.5˝ )
Breathers: RebuildableSteelBreathers(DC-RS-15, DC-RS-25,DC-RS-50,DC-RS-75)
DC-13-40C
FeaturedAbove DC-13-40C
Multiple Breather Adapters
DC-ME-2-T DC-ME-3-T DC-ME-4-TBreather Connection: Connectstwo,three,orfourStandardDisposable(DC-2,DC-3,DC-4),Ventguard(DC-VG-2, DC-VG-3),Hydroguard(DC-HG-8)breatherstoa1”femaleNPTadapter
Equipment Connection Port/Size: 2˝FemaleNPT
Breathers: StandardDisposable,Ventguard(DC-VG-2, DC-VG-3),Hydroguard(DC-HG-8)
FeaturedAbove DC-ME-3-T
Breather Connection: ConnectsRebuildableSteelBreathers(DC-RS-100,DC-RS-150,andDC-RS-200)to4˝femaleNPTadapter
Equipment Connection Port/Size: 8boltcircularmounting(Ø9.0˝ )
Breathers: Rebuildable Steel Breathers (DC-RS-100,DC-RS-150,DC-RS-200)
Extreme Duty Breather Adapters
DC-XDVA-12MBreather Connection: VentValveAdapterconnectsExtremeDutyBreather(DC-XD-6)to11/2˝x16UNmaleadapter
Equipment Connection Port/Size: 3/4˝FemaleNPT
Breathers: ExtremeDutyBreather(DC-XD-6)
DC-DSA-10Breather Connection: ConnectsExtremeDutyBreather (DC-XD-6)to11/2˝x16UNmaleadapter
Equipment Connection Port/Size: 1˝FemaleNPT
Breathers: ExtremeDutyBreather(DC-XD-6)
DC-DSA-17Breather Connection: ConnectsExtremeDutyBreather (DC-XD-6)to11/2˝x16UNmaleadapter
Equipment Connection Port/Size: 3/4˝FemaleNPT
Breathers: ExtremeDutyBreather(DC-XD-6)
DC-XDVA-16MBreather Connection:VentValveAdapterconnectsExtremeDutyBreather(DC-XD-6)to11/2˝x16UNmaleadapter
Equipment Connection Port/Size: 1̋ FemaleNPT
Breathers: ExtremeDutyBreather(DC-XD-6)
Bre
athe
rs
Portable Filtration
Dedicated Filtration
Fluid Handling a proactive approach to contamination control
Fluid Handling Products
Activelyfilteringlubricantscandramaticallyimproveindustrialequipmentperfor-mance,preventingproductiondowntimeandhighmachineryrepaircosts.TakingaproactiveapproachtocontaminationcontrolwithDes-Casefluidhandlingproductswillensureyourequipmentperformsasitwasdesignedto.
Des-Caseprovidesawidearrayofcustomizable,qualityfluidhandlingsolutionsforeverystepofyourcontaminationcontrolprogram.Thebroaddepthofproductsrangefromvarioussizesofofflinefiltrationsystemstoensurecleantransferofoil,dedicatedfiltrationsystemsthatperformaroundtheclock,lubricantstorageandhan-dlingsystems,adapterkitsforeasysystemconnection,vacuumdehydrationforwaterremoval,andmuchmore.
Portablefiltrationunitsareidealtoolstoremediatecontaminatedsystems,flushnewequipmentduringcommissioning,orperiodically decontaminate systems that have inadequateon-boardfiltrationtomeettargetcleanliness levels.
Whetheryouhaveanapplicationthatneedsregularfiltration,oramaintenancelocationwhereyoubringequipmenttobefiltered,permanently-mountedfiltrationisusuallythebestchoiceforimprovingequipmentreliabilitybecauseitiscontinuous-duty,“always-on”filtrationthatcleanstheoilandthenkeepstheoil clean.
Fluid Handling Products
Filter Elements
Des-Caseoffersanarrayoffilterelementstotacklewater,particulate,varnish,sludgeandacidremovalinawidevarietyofindustrialapplications.
Adapter Kits
Adapterkitsfunctionastheconnectionbetweenyourapplicationandfiltrationsystem.Pairingfluidhandlingfiltrationwithbreatherprotectionallowsformaximumsystemintegrity−requiringlessequipmentandlaborwhilereducingsystemcontamination.
Fluid
Han
dling
Lubricant Storage & Filtration
Des-Casecombinesfiltration,storageandbreathertechnologieswithitslubricantmanagementsystemstoproperlystoreandpre-filterlubricants.Thesimple,stackabledesignfreesupvaluablefloorspaceinanyluberoom.Dedicatedfiltrationpercontainerensuresnocross-contaminationoffluids,whiledisposable desiccant breathers prevent dirt andwateringression.
Water Removal
Activelyfilteringmoisturefromlubricantscanpreventcontamination-relatedproblemssuchasoxidation,degradation,andcorrosion. Des-Caseprovidessolutionstoremovebothsmallandlargequantitiesoffree,emulsifiedanddissolvedwatertokeepyourlubricantsclean and dry.
Lubricant Management Systems Multi-function contamination control
Features
• Dual-stagefiltration
• Dedicatedpumpandmotorpertank
• Filter bypass
• Stackabledesign
• Breathermountingkitstokeepoildry
• 75,150and300gallonsteeltankoptions
Benefits
• Opensupvaluablefloorspace
• Allowsforusewithmanylubricanttypes
• Eliminates cross-contamination
• Easy to install
TheLubricantManagementSystem(LMS)byDes-Casecombinesfiltrationandbreathertechnologiestokeepyourlubricantscleananddrybeforetheyenteryourequipment.
Combiningeasystoragewithsolidcontaminationcontrolpractices,thesturdy,stackable,andcustomizablepodsfreeupvaluablefloorspace.Featureslikedual-stagefiltration,timers,quickdisconnects,anddesiccantbreatherfiltersmakethisall-in-onesystemidealforanylubestorageroom.
Lubricant Storage & Filtration—Fluid Handling Products
LT Series Lubricant Management Systems Simple, stackable contamination control
Features
• Dedicatedpumpandmotorpercontainer
• Stackabledesign
• Desiccantbreatherskeepoildry
• Sample ports
• Manual/gravitydrain
• 12´hoseassemblieswithvarioushose-end connections
• Variousflowratesupto10gpmavailableinelectricandpneumaticconfigurations
• 75,150and300gallonsteeltankoptions
• 80,120,180and240highdensitypolyethylenetankoptions
Benefits
• Eliminates cross-contamination
• Allowsformanylubricanttypes
• Costeffective,simplewaytostoreandfilter oil
• Easy to install
TheLTSeriesLubricantManagementSystem(LT-LMS)byDes-Caseisacosteffective,simplewaytokeepyourlubricantscleananddrybeforethey enteryourequipment.
Fluid
Han
dling
Fluid Handling Products—Lubricant Storage & Filtration
T H E C L E A N L I N K B E T W E E N N E W O I L A N D E Q U I P M E N T.
IsoLink™ Oil Transfer Containers provide the first best practice solution to keep oil clean and dry during oil transfer. With non-desiccant and desiccant breather options available, as well as quick connects for clean filling, IsoLink™ isolates oil from the environment providing the ultimate in best practice contamination control.
Assessment Lite Full Assessment Enterprise Assessment
BenchmarkSurvey Benchmarkscoreineachofthetenkeycategoriesofprecisionlubricationbasedona50-questionsurvey.
Benchmarkscoreineachofthetenkeycategoriesoflubricationbestpractic-esbasedon50-questionsurvey.On-sitepersonnelcanhelpyoucompletethissurvey.
Benchmarkscoresineachofthetenkeycategoriesoflubricationbest practices based on 50-questionsurveyforeachplant,plusarankingofeachplantrelativetoothersinthesamebusi-nessunit.
GapAnaylsisandCat-egorySpecificRecom-mendations
General recommenda-tionsforbestpracticesineachofthetencategoriesofprecisionlubrication.
Customizedrecommen-dationsforbestpracticesineachofthetencatego-riesofprecisionlubrica-tion,includingaplant-specificgapanalysis.
Customizedrecommen-dationsforbestpracticesineachofthetencatego-riesofprecisionlubrica-tion,includingaplant-specificgapanalysisbased on a representative sampleofplantsincludedin the enterprise assess-ment(lowerquartile,aver-age,andupperquartileperformers).
BusinessCaseAnalysis Estimationofcurrentloss-esduetosubstandardlubricationpractices.
Estimationofcurrentlossesduetosubstan-dardlubricationpracticesand investment analysis detailingreturnoninvest-mentforimplementingspecific action items.
Estimationofcurrentlossesduetosubstan-dardlubricationpracticesforeachplantandbusi-nessunit-wideinvestmentanalysisdetailingreturnoninvestmentforimple-mentingrecommendedaction items.
Project Plan and Action Item List
Generallistofrecom-mended action items based on specific re-sponses to the bench-marksurvey.
Specificlistofrecom-mended action items based on response to the benchmarksurvey,plusa detailed project plan includingactionitems,timelines and implemen-tationsupport.
Listofrecommendedac-tionitemsforeachplants,based on response to the benchmarksurvey,plusa detailed project plan includingactionitems,timelines, and implemen-tationsupport.
Post-SurveyWrapUpandSupport
TwohourteleconferencewithDes-Caseprojectplanner,plusongoingimplementationsupport.
Fourhourpost-surveyre-portandstrategysession,ongoingimplementationsupportandmonthlyproject review sessions viateleconference.
Four-hourpost-surveybusinessunit-widereportandstrategysession,ongoingimplementa-tionsupportandmonthlyproject review sessions viateleconference.
Lubrication
Lubrication TransformationSM Services
Thousands of satisfied Des-Case product users around the world enjoy an outstanding record of trouble-free service and quality product support. If you have questions regarding Des-Case products, one of our trained professionals will assist you in getting the information you need quickly.
TM