Kick Solutions Specification Guide Working With This Specification Guide Ten Tips: How to Get the Most Out of This Book 2 Additional Resources 4 Kick Solutions Understanding 5 Specifying 161 Kick Freestanding Metal Desk Understanding 327 Specifying 345 Lighting Understanding 367 Specifying 383 Surface Materials 395 Resources 409 Availability Electronic price list updated with release 182.C (U.S.) and 147.C (Canada), dated August 17, 2015. Spec News is available on village.steelcase.com. Search AdStock and download the current release’s Spec News. View or download Steelcase Specification Guides at http://www.steelcase.com/en/resources/design/ spec-guides/pages/specguides.aspx. Transitional products in this specification guide are maintained for existing customers only and are likely to be phased out over time. These products are indicated with a S. Products that are sched- uled to be culled are indicated with an G, followed by the last order entry date. cFor a list of all trademarks, refer to the last page of this specification guide. © 2015 Steelcase Inc. For Canadian Pricing Canadian factor can be found at steelcase.com/CADpricing. Calculate in the following order to avoid rounding errors: • Multiply the base price and each option by the Canadian factor. • Round each to the nearest dollar. • Add base and options for total list price. August 2015

Upload: others

Post on 20-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Kick SolutionsSpecification Guide

    Working With This Specification Guide

    Ten Tips: How to Get the Most Out of This Book 2

    Additional Resources 4

    Kick Solutions

    Understanding 5

    Specifying 161

    Kick Freestanding Metal Desk

    Understanding 327

    Specifying 345

    Lighting

    Understanding 367

    Specifying 383

    Surface Materials 395

    Resources 409

    AvailabilityElectronic price list updated with release182.C (U.S.) and 147.C (Canada), dated August 17, 2015.

    Spec News is available on village.steelcase.com. Search AdStock and download the currentrelease’s Spec News.

    View or download Steelcase Specification Guidesat http://www.steelcase.com/en/resources/design/spec-guides/pages/specguides.aspx.

    Transitional products in this specification guide aremaintained for existing customers only and arelikely to be phased out over time. These productsare indicated with a S. Products that are sched-uled to be culled are indicated with an G, followedby the last order entry date.

    cFor a list of all trademarks, refer to the last pageof this specification guide.© 2015 Steelcase Inc.

    For Canadian PricingCanadian factor can be found atsteelcase.com/CADpricing.Calculate in the following order to avoid rounding errors:• Multiply the base price and each option by the Canadian factor.• Round each to the nearest dollar.• Add base and options for total list price.

    August 2015

    https://village.steelcase.comhttp://www.steelcase.com/en/resources/design/spec-guides/pages/specguides.aspx

  • 2 Kick Solutions Specification Guide

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tip 4Study the product detail pages in the Understanding section to learn everything an expert knows about specific products. Each product detail page in this section contains the following features, where applicable:• Product Drawing• Actual Dimensions• Product Details• Connections• Wiring and Cabling• Surface Materials• Application Topics

    Ten Tips: How to Get the Most Out of This Book

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tip 1

    Watch the tabs on theright-hand edges of thepages. They’ll always indi-cate which chapter you are in.

    Ch

    ap

    ter N

    am

    e

    Tip 2

    Use the Statement ofLine pages for an over viewof the available components,their sizes, and page refer-ences for additional informa-tion. Each Under standingchapter includes a statementof line after the table of contents.

    Tip 3

    Find cross referencesby looking for page numbersflagged with an arrow.

    Product Drawing shows you what the productlooks like and points outimportant features.

    Product Detailsgives specific information onthe product and how it is used.

    Connectionsdescribes how the productis assembled or how itattaches to another product.

    Actual Dimensions table lists the dimensions of the product.

    Wiring and Cablingdetails the power and cable-management and cable routing capabilities of the product.

    Surface Materialslists what material is usedfor each part of the product.

    ...............................................................................................................................................

    ...............................................................................................................................................

    August 2015

  • Kick Solutions Specification Guide 3

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    78"H

    U.S. CANADADStyle DBase DBase PricedNumber dPrice dd d dd d dZone 1 dZone 2

    TS77818PF $450 $585 $608

    TS77824PF $470 $611 $635

    TS77830PF $498 $647 $673

    TS77836PF $524 $681 $708

    TS77842PF $559 $727 $756

    TS77848PF $610 $793 $825

    N.A.

    N.A.d d d d

    For Canadian OrdersThe “ship-to” destination willdetermine whether Zone 1pricing or Zone 2 pricingshould be used.cPage 1

    Tackable Acoustical Panel Packages

    Answer Specification Guide 75

    Specification Information

    42"H 54"H

    U.S. CANADA U.S. CANADADWidth DStyle DBase DBase Price DStyle DBase DBase Priced dNumber dPrice d dNumber dPrice dd d d d d d dd d d dZone 1 dZone 2 d d dZone 1 dZone 2

    18" TS74218PF $232 $302 $314 TS75418PF $242 $315 $328

    24" TS74224PF $254 $330 $343 TS75424PF $266 $346 $360

    30" TS74230PF $280 $364 $379 TS75430PF $292 $380 $395

    36" TS74236PF $306 $398 $414 TS75436PF $318 $413 $430

    42" TS74242PF $337 $438 $456 TS75442PF $347 $451 $469

    48" TS74248PF $380 $494 $514 TS75448PF $390 $507 $527

    60" TS74260PF $479 $623 $648 TS75460PF $491 $638 $664

    72" TS74272PF $553 $719 $748 TS75472PF $573 $745 $775d d d d d d d d d

    66"H

    U.S. CANADADWidth DStyle DBase DBase Priced dNumber dPrice dd d d dd d d dZone 1 dZone 2

    18" TS76618PF $302 $393 $409

    24" TS76624PF $326 $424 $441

    30" TS76630PF $350 $455 $473

    36" TS76636PF $376 $489 $509

    42" TS76642PF $407 $529 $550

    48" TS76648PF $450 $585 $608

    60" TS76660PF $577 $750 $780

    72" TS76672PF $657 $854 $888d d d d d

    Tip: 78"H full-skin panelscannot accommodatedirectional fabrics. Usesegmented panels fordirectional fabrics.

    Pa

    ne

    ls

    Performance Tackable Acoustical Panel Packages

    74 Answer Specification Guide

    Standard Includes Required to SpecifycNeed help?

    Product details,page 000

    • Full tackable acoustical skins on both sides of panel:fabric price group AException: 78"H panels are standard with fabric pricegroup 1 fabrics. Base price for 78"H panels (at right)includes fabric price group 1 fabrics.

    • Top cap: color default determined by trim paint color• Trim: painted steel• Base raceway space• Cable lay-in tray• Two horizontal connecting bars

    1 Style number2 Fabric color number for side 13 Fabric color number for side 24 Paint color number for trim5 Options, if selected (see below)cSee Surface Materials, page 000.

    Tip: Remember to orderjunctions to connect adja-cent panels.cPage 000

    Tip: COM option is pricedas fabric price group 2.

    Side 1 Side 2

    Tip: Remember to orderreceptacles and faceplates.cPages 000 and 000

    Tip: 18"W panels canaccommodate pass-throughpower only.

    Options U.S. Zone 1 Zone 2 Required to SpecifySurface Panel surfaceMaterials • Fabric price group 1 each side +$ 6 +$ 8 +$ 8 Specify fabric color number.

    • Fabric price group 2 each side +$ 18 +$ 23 +$ 23 Specify fabric color number.

    Power with • One pass-through power harness +$117 +$152 +$158 Specify with one pass-through3+1, 2+2, or 18"W to 48"W harness and indicate wiringthree separate schematic type (3+1, 2+2, or 3SN).neutrals (3SN) • One pass-through power harness +$130 +$169 +$176 Specify with one pass-throughwiring 60"W or 72"W harness and indicate wiringschematics schematic type (3+1, 2+2, or 3SN).

    • Two pass-through power harnesses +$234 +$304 +$316 Specify with two pass-through18"W to 48"W harnesses and indicate wiring

    schematic type (3+1, 2+2, or 3SN).• Two pass-through power harnesses +$260 +$338 +$352 Specify with two pass-through

    60"W or 72"W harnesses and indicate wiringschematic type (3+1, 2+2, or 3SN).

    • One power kit 24"W to 48"W +$156 +$203 +$211 Specify with one power kit andindicate wiring schematic type(3+1, 2+2, or 3SN).

    • One power kit 60"W or 72"W +$273 +$355 +$369 Specify with one power kit andindicate wiring schematic type(3+1, 2+2, or 3SN).

    • Two power kits 24"W to 48"W +$312 +$406 +$422 Specify with two power kits andindicate wiring schematic type(3+1, 2+2, or 3SN).

    • Two power kits 60"W or 72"W +$546 +$710 +$738 Specify with two power kits andindicate wiring schematic type(3+1, 2+2, or 3SN).

    • One pass-through power harness +$273 +$355 +$369 Specify with one pass-throughand one power kit 24"W to 48"W harness and one power kit and

    indicate wiring schematic type(3+1, 2+2, or 3SN).

    • One pass-through power harness +$403 +$524 +$545 Specify with one pass-throughand one power kit 60"W or 72"W harness and one power kit and

    indicate wiring schematic type(3+1, 2+2, or 3SN).

    Top Cap • Change-of-height cable routing +$ 8 +$ 10 +$ 10 Specify with change-of-height,at one end of top cap one end.

    • Change-of-height cable routing +$ 12 +$ 16 +$ 16 Specify with change-of-height,at both ends of top cap on 36"W both ends.and wider panel

    Tip: Change-of-height topcap is not available on 78"Hpanel.

    Ten Tips:How to Get the Most

    Out of This Book

    Tip 6

    Italic typeface on speci-fying pages usually identifieswording that you should usein your order.

    Tip 7

    Watch for tips throughoutthe text that give you expla-nations and helpful instructions.

    Tip 8

    Learn what you cannotdo by looking for drawingscrossed out with an “X.”

    To determine how manskins are needed to com-plete a panel, consult thetable at right.Tip: Remember to orderskins for both sides of thepanel buildup.

    Tip 9Use the surface mate-rials listings in theSurface Materials section ofthis book to find surfacematerial color numbers. cPage 396

    Tip 10

    Refer to the style num-ber index when you knowa style number and youneed to find the page thathas more details about theproduct.cPage 414

    StyleNumber

    TS7042BL

    TS7042S

    TS7048BL

    TS7048S

    TS7060BL

    TS7060S

    TS7072BL

    Page

    131

    130

    131

    130

    131

    130

    131

    Tip 5Refer to the specifying pages for all the information needed to order a product. Each product specifying page contains a variety of elements to help you complete a specification:• Product Drawing• Standard Includes• Required to Specify• Options• Related Products• Specification Information • Dimensions • Style Number • Price

    Product Drawingshows you what the product looks like.

    Related Productsprovide specification infor-mation for products that aredirectly related.

    Standard Includes(under the dark grey band)provides a list of whatcomes standard with theproduct.

    Required to Specify(under the dark grey band)itemizes the information thatyou must provide to orderthe standard product and thepreferred sequence forspecification.

    SpecificationInformation(under the light grey band)provides product dimen-sions, style numbers, andprices for the standardproduct and any surfacematerial choices that areavailable.

    Options(under the black band) listsall the options that apply tothe product, their price, andwhat is required to specify.

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    August 2015

  • Additional Resources

    Kick is supported with anarray of informational materi-als, tools, and software tohelp you plan and install efficiently.

    Product brochures andplanning tools can beordered through yourSteelcase area office by calling 1.800.784.0358 or through the AdStock website at village.steelcase.com.

    Printed MaterialsKick SystemsFurniture BrochureForm Number 06-0001593

    Kick Thought StartersForm Number T3232

    Storage SpecificationGuide contains storage thatattaches to Kick.

    Quick Ship GuideThis handbook describes all Steelcase, Turnstone,Details, and Coalesse prod-ucts that are available forRapid2 (ships in 2 days),Rapid5 (ships in 5-7 days),or Coalesse Rapid10 (shipsin 10 days).

    U-Free ProductBrochureThis 8-page brochure intro-duces the U-Free family offreestanding solutions,including traditional and con-temporary desk applications,tables and storage. Includesan abbreviated statement ofline.Form number 08-0000159

    Surface MaterialsReference ManualThis publication provides:• An explanation of the

    surface materials program• “Available on” matrices• Vertical surface fabric and

    seating upholstery selec-tion listing

    • Technical data for surfacematerials

    • Surface material care andcleaning instructions

    Computer ToolsElectronic CatalogAccurate sales quotationsand purchase orders for Kickproducts are created withspecification software thatuses Kick Electronic Catalogdata. Use the data to specifyand price style numbers andoptions for every Kick prod-uct. The data is updatedbimonthly by Steelcase andprovided to software pro-grams like the HedbergBusiness System, 20-20CAP Studio.

    Furniture SymbolGraphic Data Steelcase creates 2D and3D furniture symbols (withattributes) for planning andinitially specifying Steelcaseproducts. This data is incor-porated into several add-onsoftware packages that workin either a Microstation or anAutoCAD drafting environment.

    For more information aboutthese and other softwaretools to help you plan effective work environments,please email [email protected]

    Digital PublicationsIf your device has a bar codereader App, scan this QRcode for a direct link to theonline digital public ations.Utilizing this QR code allowsyou to search across multiplespecification guides, shareacross social media, or printout pages. You can alsoaccess these digital publica-tions at www.steelcase.comor village.steelcase.com.

    Kick Product TrainingBasic training for the Kicksystems products is avail-able as part of the BuildingProduct Muscle (BPM) cur-riculum on the SteelcaseUniversity Web site at village.steelcase.com.

    The Kick BPM is an interac-tive, web-based course,filled with photos, detailedpositioning, statement ofline, features/advantage,application, and specificationinformation, as well as prac-tice exercises designed tobuild salespeople’s knowl-edge of the Kick system.The course also containsprintable job aids to provideongoing performance sup-port. The Kick BPM iscourse SAL188.

    SupportSteelcase CapabilitiesSteelcase products are dis-tributed, installed, and serv-iced through a network ofmore than 600 dealersworldwide. Steelcase is alsorepresented with offices andcorporate showrooms in 26U.S. cities, 4 Canadian cities,and in France, Germany,Great Britain, and Japan.Every Steelcase productmeets our exceptionally highstandards of quality anddurability and comes withthe Steelcase assurance ofexcellence in service.

    For assistance, pleasecall your local dealer, theSteelcase SolutionsResource Team, or theSteelcase SolutionsFulfillment Team at1.800.STEELCASE(1.800.887.6786).

    Call the Steelcase SolutionsFulfillment Team if you have submitted an order toSteelcase and you need to speak to your SolutionsFulfillment Team Repre -sentative about the order.Also call if you have anypost-shipment quality orwarranty concerns or service parts questions.

    Outside the U.S.A., Canada,Mexico, Puerto Rico, andthe U.S. Virgin Islands, call1.616.247.2500.

    4 Kick Solutions Specification Guide

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    August 2015

    https://village.steelcase.comhttps://village.steelcase.comhttps://village.steelcase.comhttp://www.steelcase.com

  • Kick Solutions Specification Guide 5

    Panels 7

    Wiring and Cabling 35

    TS Series Worksurfaces and Supports 55

    Universal Systems Worksurfaces and Supports 71

    TS Series Storage Products 103

    Universal Storage Products 123

    UnderstandingKick Solutions

    August 2015

  • 6 Kick Solutions Specification Guide

    August 2015

  • UnderstandingPanels

    Kick Solutions Specification Guide 7

    Statement of Line 8

    Monolithic Panels 10Segmented Panels and Stacker Options 12Stackers 14Panel Frame and Inserts 16Connectors 18Off-Module Connections 20Panel Trim 22Sliding Panel Door 26

    Stability Guidelines 28

    Pa

    ne

    ls

    August 2015

  • 8 Kick Solutions Specification Guide

    Statement of LinePanels

    UnderstandingcPage 10 SpecifyingcPage 164

    Monolithic Panels 24"W 30"W 36"W 42"W 48"W 60"W

    42"H • • • • • •48"H • • • • • •54"H • • • • • •66"H • • • • • •

    UnderstandingcPage 12 SpecifyingcPages 166

    Segmented Panels 24"W 30"W 36"W 42"W 48"W 60"W

    42"H • • • • • •48"H • • • • • •54"H • • • • • •66"H • • • • • •

    UnderstandingcPage 14 SpecifyingcPage 172

    Panel Stackers 24"W 30"W 36"W 42"W 48"W 60"W 72"W

    12"H • • • • • • •18"H • • • • • • •24"H • • • • • • •

    UnderstandingcPage 16 SpecifyingcPage 174

    Panel Frames 24"W 30"W 36"W 42"W 48"W 60"W

    42"H • • • • • •54"H • • • • • •66"H • • • • • •

    UnderstandingcPage 16 SpecifyingcPage 176

    Panel Inserts 24"W 30"W 36"W 42"W 48"W 60"W

    42"H • • • • • •54"H • • • • • •66"H • • • • • •

    Vertical End-of-Run Trim 42"H 48"H 54"H 60"H 66"H 72"H 78"H

    Standard • • • • • • •

    UnderstandingcPage 22 SpecifyingcPage 177

    August 2015

  • Kick Solutions Specification Guide 9

    Pa

    ne

    ls

    Statement of Line

    Change-of-Height Trim 6"H 12"H 18"H 24"H 36"H

    Standard • • • • • High • • • • •

    UnderstandingcPage 22 SpecifyingcPage 178

    20%

    UnderstandingcPage 26 SpecifyingcPage 184

    Sliding Panel Doors 66"H 78"H

    36"W • •42"W • •

    August 2015

  • Monolithic Panels

    Panels are constructedwith a rigid, tubular steelframe and are shipped fullyassembled. Remember toorder trim separately.cSpecifying, page 164.

    Wire separator for thepanel base can be orderedthrough Kick Service Partsto provide a separate, iso-lated space for routing dataand telecommunicationcables. It also serves as asecond metallic barrierbetween low-voltage com-munication wires and 120-volt electricity.

    Actual DimensionsHeight 42", 48", 54", or 66"

    Width 24", 30", 36", 42", 48", or 60"

    Thickness 2"

    Base Raceway Height 35⁄8"

    Glides 11⁄2" adjustment

    ...............................................................................................................................................

    ...............................................................................................................................................

    10 Kick Solutions Specification Guide

    1/4"

    2"

    Vertical slots in panelaccommodate hang-on components, overhead storage bins, shelves, worksurface supports, and connector brackets.Components can bemounted at 1" increments.

    Base cavity accepts afactory- or field-installedpowerway. Cable routing isalso possible. cSee Powerway Facts,page 42.

    Leveling glides adjust11⁄2" to install panels onuneven floors.

    Steel top caps are avail-able in two heights—low isstandard and high is avail-able as an option. High topcap will accommodate cablerouting at the top of thepanel.

    Removable base coverhas receptacle knockouts.Base covers have one stan-dard-size opening on the leftand an opening for a stan-dard- or larger-size recepta-cle opening on the right.Exception: 24"W and 30"Wbase covers have a stan-dard-size opening on oneside of the panel openingand a larger size on thereverse side.

    Horizontal slotsaccommodate off-moduleconnections.

    August 2015

  • Kick Solutions Specification Guide 11

    Pa

    ne

    lsP

    an

    els

    Surface MaterialsBase cover, top cap,and border• Paint

    Panel surface• Fabric• 6500 Clear Glass• Perforated Steel: Paint

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product Details

    Kick panels come in fourtypes.

    Tackable acoustical—skin on each side, coveredwith vertical surface fabric.

    Segmented—tackableskins on one or both sides,covered with vertical surfacefabric.

    Glass—single pane ofclear, tempered safety glasson panel centerline, sur-rounded by painted border.Glass panels can acceptglass stackers.

    Perforated steel—singlepane of painted, perforatedsteel on panel centerline,surrounded by painted bor-der. Perforated patternmatches large perforatedpattern on TS storage.

    Wiring & CablingPanel frames have hollowinterior to allow routingcables from top cap throughto base raceway.

    Kick is available with anoptional high top cap toaccommodate additionalcable capacity at the top ofthe panel.

    Monolithic Panels

    August 2015

  • 42"H Base panels with stacker

    42"

    12"

    42"

    18"

    42"

    24"

    42"

    12"

    12"

    42"

    18"

    18"

    42"

    12"

    12"

    12"

    42"

    12"

    18"

    42"

    12"

    24"

    42"H Base panels

    42"

    30"

    12"

    48"H Base panels with stacker

    48"

    12"

    48"

    18"

    48"

    24"

    48"

    12"

    12"

    48"

    12"

    18"

    48"H Base panels

    48"

    30"

    18"

    54"H Base panels with stacker

    54"

    12"

    54"

    18"

    54"

    24"

    54"

    12"

    12"

    54"H Base panels

    54"

    30"

    24"

    30"

    12"12"

    66"H Base panels with stacker

    66"

    12"

    66"H Base panels

    66" 54"

    12"

    42"

    24"

    42"

    12"

    12"

    42"

    12"

    48"

    18"

    30"

    24"

    12"

    30"

    12"

    24"

    12 Kick Solutions Specification Guide

    Segmented Panels and Stacker Options

    ...............................................................................................................................................

    ...............................................................................................................................................

    Kick allows a wide varietyof panel arrangements tomeet specific func tional andaesthetic needs. Panels arenot dedi cated to a specificlocation and can be usedanywhere on the face of thepanel. Illustrations showlargest sized skin in bottom position.

    Stacking Guidelines

    Stackers are available in12"H, 18"H, or 24"H in fab-ric, glass, or perforatedsteel.

    Maximum height is 78".

    Maximum number ofstackers is three.

    Any height base panelcan be used with stackers.

    ...............................................................................................................................................

    Segmented Panels Stacker Options

    August 2015

  • Kick Solutions Specification Guide 13

    Pa

    ne

    ls

    Segmented Panels andStacker Options

    August 2015

  • Stackers

    Stackers are constructedwith a rigid, tubular steelframe and are shipped fullyassembled.cSpecifying, page 172.

    Actual DimensionsHeight 12", 18", or 24"

    Width 24", 30", 36", 42", 48", 60", or 72"

    Thickness 2"

    ...............................................................................................................................................

    ...............................................................................................................................................

    1/4"

    2"

    Horizontal slots in stack-ers, identical to slots in basepanels, accommodate off-module panel connections.

    Vertical slots in stack-ers, identical to slots in basepanel, accommodate over-head storage and hang-oncomponents, and connectorbrackets. Components can be mounted at 1" increments.

    Top cap and top capaligner from base panelare used to trim the top ofstacker.

    14 Kick Solutions Specification Guide

    August 2015

  • Stackers

    Application TopicsMaximum height withbase panel and stack-ers cannot exceed 78".

    Maximum number ofstackers is three.

    Any base panel canaccept stackers.

    Bins and shelves canhang from first, second, orthird stacker, not above 66"in height.

    Surface MaterialsBorder• Paint

    Panel surface• Fabric• 6500 Clear Glass

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product DetailsAll existing base pan-els accept stackers.

    Stackers do not includevertical trim, must be speci-fied separately.

    Base panels can acceptone, two, or three stackers,up to a total height of 78". Allstackers are load bearing,but load cannot be mountedabove 66" height.cSee page 12.

    Two fork connectorsare included with everystacker.

    Attaching stackers topanels will not cause dis-ruption to existing panel connections.

    Spanning stackers areavailable in 48", 60", or 72".

    Stacker can span over anin-line connection betweentwo base panels or twostackers. Width of stackermust equal total width of twobase panels.

    Up to78"H

    Two smaller stackerscannot be attached to thetop of a larger stacker orpanel.

    Kick stackers are avail-able in two surface options.

    Tackable acoustical—skin on each side, coveredwith vertical surface fabric.

    Glass—single pane ofclear, tempered safety glasson panel centerline, sur-rounded by painted border.

    Kick Solutions Specification Guide 15

    Pa

    ne

    ls

    August 2015

  • Panel Frame and Inserts

    Panel frames andinserts, specified separately,are used together to dividespace while achieving a moreopen and customized environ-ment. Frame is identical to the frame used for tackableacoustical, segmented, glass,and perforated steel panels.cSpecifying, pages 174-176.

    Panel frames are availablein three heights and sixwidths.

    Actual DimensionsHeight 42", 54", or 66"

    Width 24", 30", 36", 42", 48", or 60"W

    Thickness 2"

    Base Raceway Height 35⁄8"

    Glides 11⁄2" adjustment

    ...............................................................................................................................................

    ...............................................................................................................................................

    1/4"

    2"

    Horizontal slots accom-modate off-module panel connections.

    Vertical slots in panelframe accommodate hang-on components, overheadstorage bins, shelves, work -surface supports, and connector brackets.Components can bemounted at 1" increments.

    Steel top caps are avail-able in two heights—low isstandard and high is avail-able as an option. High topcap will accommodate cablerouting at the top of thepanel.

    16 Kick Solutions Specification Guide

    Removable base coverhas receptacle knockouts.Base covers have one stan-dard-size opening on the leftand an opening for a stan-dard- or larger-size recepta-cle opening on the right.Exception: 24"W and 30"Wbase covers have a stan-dard-size opening on oneside of the panel openingand a larger size on thereverse side.

    Base cavity accepts afactory or field installed pow-erway. Cable routing is alsopossible.

    Four jamb blocks, stan-dard with each insert, areused to attach insert topanel frame.

    August 2015

  • Panel Frame and Inserts

    Surface MaterialsFrame• 0835 Black• 4798 Sterling

    Base and top cap• Paint

    Translucent insert• 6505 Frosted White• 6507 Frosted Green

    Laminate insert• 2T03 Brushed Silver E• Laminate

    Jam blocks• 6000 Black Plastic only

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product DetailsInserts are available in twochoices—translucent andlaminate—to accommodateuser needs.

    Translucent insert,frosted acrylic, is 1⁄4" thick. Itis not available for order inCanada.

    Laminate insert is 1⁄4"thick. It is manufacturedusing a low-pressure lami-nate process and has a dec-orative finish on both sideswith a color-matched edge.It is not available for order inCanada.

    Space between insertand frame (1⁄2" on eachside) is part of the openaesthetic.

    Application TopicsFactory-installedpower or field installa-tion option replaces theneed to order separate powerways.

    Remember to order trimpackages.

    Kick Solutions Specification Guide 17

    Pa

    ne

    ls

    August 2015

  • Connectors

    Universal connectorpackage joins panels ofthe same height in a straight line or in L-, T-, or X-configu-rations. The package, stan-dard with panels, containstwo universal connectors—one for the top and one forthe bottom connection.cSpecifying, page 182.

    ...............................................................................................................................................

    ...............................................................................................................................................

    18 Kick Solutions Specification Guide

    Same connector is usedat both the top and bottom ofpanel.

    Different slots are usedto create in-line, L-, T-, or X-conditions.

    Change-of-Height Connector

    RightHand

    LeftHand

    Wall Start

    120° ConnectorStandard Connector

    Off-Module Connector—Universal

    Top brackets Bottom brackets

    Off-Module Connector—Panel Width-Specific

    Top brackets

    Bottom slotted rail

    Bottombrackets

    August 2015

  • Connectors

    Surface MaterialsUniversal and 120°connector• 0835 Black

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product Details

    Wall start connectorpackage is used to anchora panel run to a perpendicu-lar wall. Mounting screwsthat connect the brackets tothe panel are included ineach package.Tip: Vertical end-of-run trimis not required at the end ofpanel that is attached to thewall.

    Change-of-height in-line and corner panelconnector package isused to join panels at vary-ing heights in a straight lineor at 90° angles. Packagecontains left and right con-nectors for both in-line andcorner configurations.Tip: Change-of-height in-lineand corner panel connectorscannot be used in 120° configurations.

    Left and right in-lineconnectors are requiredto connect panels in astraight line.

    One-handed corner connector is required forconnecting panels at 90°.

    To connect panels in a120° application, a 120°panel connector is required.A two-panel connectionrequires one 120° connectorpackage. A three-panel connection requires three120° connector packages.Tip: Change-of-height in-lineand corner panel connectorscannot be used in 120° configurations.cPage 182

    120° connectors arefor the same height panelsonly.

    120° and 90° connec-tions can occur within thesame workstation.

    Kick Solutions Specification Guide 19

    Pa

    ne

    ls

    August 2015

  • ...............................................................................................................................................

    Product Details

    Off-module connectorsconnect all types of Kickpanels of the same height.Connection locations are at1" increments and allow theuse of standard-size work-surfaces for workstationplanning. Stackers can bemounted on either or both ofthe panels. There is a deadzone at the last 3" of eachend of the panel where anoff-module connection can-not be made due to lack ofhorizontal mounting slots.

    Off-ModuleConnector—UniversalBottom connection requiresthe use of two self-drillingscrews (included) throughthe skin of the host panelapproximately 1⁄2" above thebase cover.

    Off-Module Connections

    20 Kick Solutions Specification Guide

    ...............................................................................................................................................

    ...............................................................................................................................................

    3"Wdeadzone

    Connection locationsin 1" increments

    3"Wdeadzone

    Kick offers true off-modulecapability with the ability tomount a return panel any-where along the spine in 1"increments.

    August 2015

  • Kick Solutions Specification Guide 21

    Off-Module Connections

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Off-ModuleConnector—Panel-Width SpecificThe panel width-specific off-module connector incorpo-rates a horizontal elementthat connects to the basefeet of the host panel. There is no defacing ofeither panel.

    Pa

    ne

    ls

    ...............................................................................................................................................

    August 2015

  • Panel Trim

    Actual Dimensions Vertical End-of-Run Change-of-Height Corner Trim Trim Trim

    Height 42", 48", 54", 42", 48", 54", 60", 6", 12", 18", or 66" 66", 72", or 78" 24", or 36"

    Standard 1⁄4" 1⁄4" 1⁄4" Thickness

    High Cable 2" 2" 2"Capacity Thickness

    ...............................................................................................................................................

    ...............................................................................................................................................

    22 Kick Solutions Specification Guide

    Vertical trim

    End-of-run trim

    Change-of-height trim

    Steel top caps are avail-able in two heights—low isstandard and high is avail-able as an option. High topcap will accommodate cablerouting at the top of thepanel.

    August 2015

  • Panel Trim

    Tip: Back filler required forcable routing capabilityand non-sequentialassembly only.

    Tip: Back filler required forcable routing capabilityand non-sequentialassembly only.

    High end-of-run capor low universal

    end cap

    Backfiller

    High in-line capor low universal

    end cap

    Backfiller

    High L end capor low universal

    end cap

    X-configurations:

    Tip: In an X-configuration,carrier and vertical cornertrim must be attached to onepanel prior to instal lation oflast panel.

    Tip: Back filler required forcable routing capability only.

    Tip: Back filler required forcable routing capability only.

    High X end capor low universal

    end cap

    High end-of-run capor low universal

    end cap

    Backfiller

    Carrier

    High T end capor low universal

    end cap

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product Details

    Vertical corner trimallows cables to be laid inbefore the cover is snappedinto place and can beremoved for cable access.Corner trim is required for L-, T-, and X-configurationsand includes a low trim endcap. High trim end caps,available as an option, areapplication specific.

    Always specify verticalcorner trim the sameheight as the tallest panel.

    L-configurations:

    T-configurations:

    Carrier

    High L end capor low universal

    end cap

    Verticalcornertrim

    High end-of-run capor low universal

    end cap

    High T end capor low universal

    end cap

    High end-of-run capor low universal

    end cap

    Kick Solutions Specification Guide cPanel Trim, continued 23

    Pa

    ne

    ls

    August 2015

  • Vertical end-of-run trimmust match height of basepanel.

    Vertical end-of-run trimmust match combined heightof base panel and stacker.

    Vertical in-line change-of-height trim is available12"H, 18"H, 24"H, and 36"Hin slim profile (standard witha low trim end cap) or withcable-routing capacity (stan-dard with a high trim endcap). Trim covers theexposed section of the tallerpanel when panels of differ-ent heights are joined.

    120° vertical cornertrim is required for all 120°connections. The same 120°vertical corner trim is usedfor two- and three-way con-nections and is availablewith a low end cap only.Both two- and three-wayend caps are included witheach 120° vertical cornertrim package.cPage 180

    Application TopicsAlways specify vertical cor-ner trim the same height astallest panel.

    When specifying abase panel and astacker, specify cornertrim to match base paneland change-of-height trimpiece to cover the ends ofstacker.

    When base panel andstacker are specified inend-of-run trim must matchtotal overall height.

    Surface MaterialsTrim• Paint

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    End caps:

    Vertical corner trimand corner change-of-height trim are required incombination for L-, T-, andX-configurations whenstackers are used. All cornertrims include a low trim endcap. High trim end caps,available as an option, areapplication specific.

    Always specify verticalcorner trim the sameheight as the tallest basepanel. Specify vertical cor-ner change-of-height trim tocover the ends of stackers.

    Vertical end-of-run trimcovers the exposed end ofpanels and includes a lowtrim end cap. High trim endcaps, available as an option,are application specific.

    Panel Trim, continued

    24 Kick Solutions Specification Guide

    August 2015

  • Panel Trim

    Kick Solutions Specification Guide 25

    Pa

    ne

    ls

    August 2015

  • Sliding Panel Door

    Actual DimensionsHeight 66" or 78"

    Width 36" or 42"

    Thickness 11⁄4"

    ...............................................................................................................................................

    ...............................................................................................................................................

    26 Kick Solutions Specification Guide

    Sliding door is handedand can be added to work-stations for additional privacy.

    Door must be installed on the outside of the workstation.

    Receiving panel heightmust match door height.

    Door is attached to the hostpanel only; therefore, thestability of the door is closelyrelated to the stability of thehost panel.

    Kick sliding panel doorframe is painted in 4798Sterling. Door infill is madeof ribbed, translucent plastic.Attachment hardware shipsstandard and attaches toKick panel.

    Universal sliding doorfor use with Kick isavailable in a variety of colors. The door infill is standard in ribbed, translu-cent plastic. Clear temperedglass and white laminatedglass are available asoptions.

    Sliding door canbe specified with lock option.Specify lock cylinder andkey separately.

    Sliding door is not free-standing; it must mount topanels.

    Door handle is integraland is ADA compliant.

    Sliding door frame andthreshold are constructedfrom extruded aluminum andpainted.

    Door slides along thresholdon wheels. Wheels have 1"adjustment for installation onuneven floors. Threshold isADA compliant.

    Height of host panelmust match height of door.

    Right-hand sliding doorcloses from left to right.

    Left-hand sliding doorcloses from right to left.

    Lock mechanism is onleft-hand side of a right-handsliding door to lock into thehost panel.

    Lock mechanism is onthe right-hand side of a left-hand sliding door.

    August 2015

  • Sliding Panel Door

    Surface MaterialsPanel door frame• Paint

    Door insert• 6500 Clear Glass• 6541 White Laminated Glass• 6625 Translucent Plastic

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Product DetailsSliding door is handed.Right-handed sliding door orleft-handed sliding doormust be specified.

    Sliding door can be specified with lock option.Specify lock cylinder andkey separately.

    Door insert is standard inribbed, translucent plastic.Clear tempered glass andwhite laminated glass areavailable as options.

    Application TopicsSliding door is not free-standing. It must mount topanels.

    Door is attached to the hostpanel only. Therefore, thestability of the door is closelyrelated to the stability of thehost panel.

    Door track is attached toboth host panel and oppo-site panel.

    Height of door mustmatch height of host panel -66"H or 78"H.

    Match the width of the hostpanel to the width of thedoor.

    When attaching thesliding door to anAnswer panel, a junctionstabilizer bracket is availablefor added rigidity to the hostpanel. If a host and/orreceiving panel run exceeds4', a junction stabilizerbracket must be applied tothe door end of the hostand/or receiving panel run.On long runs, apply a junc-tion stabilizer bracket or per-pendicular panel every 8'.

    Sliding panel door can-not attach to a host panelwith a double-pane window.

    Kick Solutions Specification Guide 27

    Pa

    ne

    ls

    August 2015

  • 28 Kick Solutions Specification Guide

    Stability Guidelines

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tackable Acoustical Panels without Components

    8' max.

    24" min.24" min.

    Two-panel run Three-panel run

    12' max.

    24" min.

    24" min.24" min.

    Four-panel run 24" min.

    16' max.

    24" min.24" min.

    Multiple panel run

    16' max.

    24" min.24" min.

    24" min.

    Panel Frames with Inserts without Components

    Two-panel run

    30" min.30" min.

    8' max.

    Four-panel run 30" min.

    30" min.30" min.

    16' max.

    Multiple panel run

    16' max.

    30" min.

    30" min.30" min.

    August 2015

  • Kick Solutions Specification Guide cStability Guidelines, continued 29

    Stability Guidelines

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tackable Acoustical Panels and Panel Frames with Inserts

    Two-Panel Run with Supported Components

    Optional worksurface supports:• 20"W H-leg• Pedestal with filler• Lateral file• End panel

    Tip: Kick overhead storage bins cannot support any load on top.

    Two-Panel Run with Upmount Bin Bracket

    Optional worksurface supports:• Pedestal with filler• End panel

    Tip: Kick overhead storage bins cannot support any load on top.

    Tip: Upmount bin brackets cannot be used in three-panel runs or 120° panel configurations.

    24" min.(must equalworksurfacedepth)

    30"Hor42"H

    10' max.

    Worksurfacetie plate

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    10' max.

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    42"H

    24" min.(must equalworksurfacedepth)

    30"Hmax.

    10' max.

    Worksurfacetie plate

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    54"H max.

    10' max.

    24" min.(must equalworksurfacedepth)

    30"Hor42"H

    Worksurfacetie plate

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    10' max.

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    42"H

    24" min.(must equalworksurfacedepth)

    30"Hmax.

    10' max.

    Worksurfacetie plate

    Overhead storagebin connector clip

    Cantilever

    Side supportbracket

    Pa

    ne

    ls

    August 2015

  • 30 Kick Solutions Specification Guide

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tackable Acoustical Panels and Panel Frames with Inserts, continued

    Three-Panel Run with Supported Components

    Optional worksurface supports at 30"H:• 20"W H-leg• Pedestal with filler• Lateral file• End panel

    Tip: Kick overhead storage bins cannot support any load on top.

    Tackable Acoustical Panels without Components

    120° Connection

    12' max.

    36" min.

    36" min.

    36" min.

    24" min.

    24" min.

    8' max.

    60" max.

    36" min.

    36" min.

    24"min.

    12' max.

    Worksurfacetie plate

    Cantilever

    Side supportbracket

    30"Hor42"H

    No center overheadstorage bin allowed

    12' max.

    Worksurfacetie plate

    Cantilever

    Side supportbracket

    Stability Guidelines, continued

    August 2015

  • Kick Solutions Specification Guide cStability Guidelines, continued 31

    ...............................................................................................................................................

    ...............................................................................................................................................

    Panel Frames with Inserts without Components

    120° Connection

    Tackable Acoustical Panels and Panel Frames with Inserts with Supported Components

    One Panel—120° Connection

    Optional worksurface supports: Optional worksurface supports:• Pedestal with filler • Pedestal with filler• 90° panel connection—panel width must match • 90° panel connection—panel width must match worksurface depth worksurface depth• End panel • 20"W H-leg

    Tip: Upmount bin brackets cannot be used with 120° panel configurations.

    12' max.

    36" min.

    36" min.

    36" min.

    8' max.

    36" min.

    36" min.

    60" max.

    30" min.

    30" min.

    Cantilever

    Cantilever

    60" max.

    36" min.

    Cantilever

    20"W H-leg

    48" max.36" min.

    36" min.

    Cantilever

    Cantilever

    Stability Guidelines

    Pa

    ne

    ls

    August 2015

  • 32 Kick Solutions Specification Guide

    Stability Guidelines, continued

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tackable Acoustical Panels and Panel Frames with Inserts with Supported Components, continued

    Two-Panel Run—120° Connection

    Optional worksurface supports:• 20"W H-leg• Pedestal with filler• 90° panel connection—panel width must match worksurface depth

    Tip: Upmount bin brackets cannot be used with 120° panel configurations.

    Three-Panel Run—120° Connection

    Tip: Same rule applies if using 120° worksurfaces in place of straight worksurfaces.

    Tip: Upmount bin brackets cannot be used with 120° panel configurations.

    12' max.

    36" min.

    36" min.

    36" min.

    10' max.

    36" min.

    Cantilever

    Cantilever withtie plate

    Cantilever

    August 2015

  • Kick Solutions Specification Guide cStability Guidelines, continued 33

    Pa

    ne

    ls

    Stability Guidelines

    ...............................................................................................................................................

    ...............................................................................................................................................

    Tackable Acoustical Panels and Panel Frames with Inserts—Three-Way 120° Connection

    Three Panel 120° Connection with One Supported Component

    Tip: Upmount bin brackets cannot be used with 120° panel configurations.

    Three Panel 120° Connection with 120° Worksurface and up to One Additional Component

    Tip: Loads must be counterbalanced in this application. Tip: Worksurface needs to be supported to floor or application needs to be counterbalanced.

    Panels and Panel Stackers

    Base panels can accept one, two, or three stackers, up to a total height of 78".See below for additional rules and exceptions.

    Universal or change-of-height connectors must be used at top of base panel and each stacker wherever possible to increase stability.

    60" max.

    48" min.

    48" min.

    Cantilever

    Cantilever

    or

    August 2015

  • 34 Kick Solutions Specification Guide

    Stability Guidelines, continued

    ...............................................................................................................................................

    ...............................................................................................................................................

    Panels and Panel Stackers, continued

    All stackers are load bearing, but load cannot be mounted above 66" height.

    42"

    12"

    12"

    42"

    24"

    12"

    42"

    24"

    August 2015

  • UnderstandingWiring and Cabling

    Kick Solutions Specification Guide 35

    Statement of Line 36

    Circuit Specifications 38How to Calculate Power Needs 39Cable Capacities 40Powerway 42Receptacle 44Integrated Power and Communication 46Power and Cable Pole 48Base Power-in 50Worksurface-Height Power and Communication 52

    Wirin

    g a

    nd

    Ca

    blin

    g

    August 2015

  • 36 Kick Solutions Specification Guide

    Statement of Line

    2" x 2" Power andCable PolescPages 48

    Base Power-InscPage 50

    Panel-MountedReceptacle Packageand CommunicationModule PackagecPage 52

    Powerway ConnectorcPage 42

    Worksurface-MountedReceptacle Packageand CommunicationModule PackagecPage 52

    ReceptaclescPage 44

    Standard size

    Larger size

    Integrated Power andCommunicationcPage 46

    Worksurface-MountedPower andCommunication SpherecPage 52

    August 2015

  • Statement of Line

    Kick Solutions Specification Guide 37

    Wirin

    g a

    nd

    Ca

    blin

    gW

    iring

    an

    d C

    ab

    ling

    August 2015

  • 38 Kick Solutions Specification Guide

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Five wiring schematicsare available for Kick—two3-circuit systems and three4-circuit systems.

    All the components inan electrical distribu-tion network must usethe same wiring schematic.The components (powerpoles, base power-ins, pow-erways, and receptacles)snap together and are keyedto make it impossible to con-nect mismatched parts.Color-coded and labeledcomponents make it easy forinstallers to identify whichwiring schematic each com-ponent is dedicated to.Color coding• 3 circuits shared = Black• 3 circuits separate = White• 4 circuits 3+D = Black• 4 circuit 3I+1 = Tan• 4 circuit 2+2 = Grey

    Circuit SpecificationsDetailed Information for the Electrical Engineer

    Overview

    3 Circuit Shared Neutral, 5 Wires

    Hot 1Hot 2Hot 3

    Oversized NeutralSystem Ground

    Three-circuit electricalcomponents withshared neutrals are stan-dard with 5 wires to providethree circuits that share oneoversized neutral and oneground. This is the traditional3-circuit power alternativethat is specified by adding thesuffix P3 to the panel stylenumber.

    Three-circuit with sepa-rate neutrals have 8 wiresproviding three circuits, eachwith its own separate neutral.The first two circuits share anisolated ground; the thirduses the system ground.

    Four-circuit 3+D are stan-dard with 8 wires to providefour circuits. Three of thesecircuits share an oversizedneutral and a system groundwhile the remaining circuithas its own neutral and iso-lated ground. This is the tra-ditional 4-circuit power, alsoknown as 3+D, that is speci-fied by adding the suffix P4 tothe panel style number.

    Four-circuit, 3I+1 againhave 8 wires but with threecircuits that share an over-sized neutral and isolatedground. The fourth circuit has its own neutral and isattached to the systemground. This electrical sys-tem is like the standard 3+D, but the grounds areswitched, providing three isolated circuits and one general purpose circuit ascompared to one isolated circuit and three general purpose circuits.

    Four-circuit 2+2 alsohave 8 wires but provide twocircuits that share an over-sized neutral and a systemground and an additional twocircuits with a second over-sized neutral and an isolatedground.

    4 Circuit 3+D, 8 Wires

    Hot 1Hot 2Hot 3Oversized NeutralSystem Ground

    Hot 4NeutralIsolated Ground

    4 Circuit 3I+1, 8 Wires

    Hot 1Hot 2Hot 3Oversized Neutral

    Isolated Ground

    Hot 4NeutralSystem Ground

    4 Circuit 2+2, 8 Wires

    Hot 1Hot 2

    Oversized NeutralSystem Ground

    Hot 3Hot 4

    Oversized NeutralIsolated Ground

    August 2015

  • Kick Solutions Specification Guide 39

    How to Calculate Power NeedsUse This to Determine How Many Power-Ins You’ll Need

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    If your usage is knownin advance:Add up the amperage usedby each piece of equipmentin the workstation. When -ever you reach 60 amps (20 amps times 3 circuits) or80 amps (20 amps times 4circuits) from items that arelikely to be used at the sametime, you have reached thelimit for a single power-in.Specify another power-inand continue until all equip -ment is powered.

    If the circuits will normallybe subject to a continuousload (three or more hours ofcontinuous use, such aslights or computers), theNEC requires that circuitcapacity be “de-rated” by 20 percent. Therefore, treatcircuits used for continuousloads as if they were ratedat 16 amps instead of theregular 20 amps.

    Try to anticipate futureincreases in power require -ments and build someexcess capacity into yourplan.cSee table at right for typi-cal and actual amperageusages for components.

    To calculate amperage whenthe wattage of a device isknown, divide watts by 120.

    Some appliances, such aslarge copiers, coffee makers,or space heaters requiremost of the current avail-able on a 20-amp circuit. Itis recommended that suchdevices be supplied withtheir own receptacle/circuit,directly from the building.This leaves the capacity ofthe furniture circuits avail -able for the more dynamicrequirements of the officeequipment.

    Local electrical codes vary.Consult a qualified electricalcontractor or engineer forthe proper planning of elec -trical circuits in your locale.

    If your usage is notknown in advance: The National ElectricalCode (NEC) allows a maxi -mum of 13 receptacles oneach 20-amp circuit. Thisprovides up to 30 recepta clesfor each 3-circuit power-inand 40 receptacles for each4-circuit power-in.

    These numbers refer toreceptacles, not outlets.All Kick receptacles areduplex and include two outlets.

    When planning a power network, you must calculatethe amperage requirementsof all your electrical compo -nents so you can providesufficient electricity to powerthem.

    Requirements of Office Equipment in Amps

    General Equipment (Typical Amperage)A.C. adapter 0.05Adding machine 0.05Answering machine 0.08Calculator 0.025Clock 0.03Coffee pot 10.00Copy machine 15.00Desk-top copiers 7.00 to 10.00Electric eraser 0.25Fan 0.50Manuscript holder 0.75Microwave 8.00 to 12.00Pencil sharpener 0.25Radio 0.05Space heater, 1000 watts 8.50Space heater, 1500 watts 12.50Stand-alone copiers 15.00

    Electronic Equipment (Typical Amperage)Desk-top memory storage devices 0.08 to 0.15

    Desk-top printers 1.20 to 2.00DVD players 0.13 to 0.20Flat-panel screens 3.50Laptops 3.50 to 5.00Modems 0.15Stand-alone printers 1.50 to 2.50VDTs and PCs 0.08 to 4.80

    Steelcase Lighting (Actual Amperage)Shelf lights 24" wide, 17 watts 0.2036" wide, 25 watts 0.3048" wide, 32 watts 0.30

    ...............................................................................................................................................

    Wirin

    g a

    nd

    Ca

    blin

    g

    How to CalculatePower Needs

    August 2015

  • Cable Capacities

    ...............................................................................................................................................

    ...............................................................................................................................................

    ...............................................................................................................................................

    Test and verify capaci-ties for your individualsituation. We recommendthat testing be conductedusing your specific cable, aswell as the furniture configu-ration you are considering.Cable capacities in thistabled are based on actualcable studies performed byan independent contractorfollowing EIA/TIA codes andpractices and can be takenas an accurate assessmentof maximum practical capac-ity. Actual cable capacitiesmay vary slightly dependingon which manufacturer pro-duced the cable and the spe-cific field conditions.

    Cable capacities arebased on Category 6 andCategory 6a cables at 55%fill capacity for cable studyperformed on junctions man-ufacturered on or afterOctober 10, 2011.Note: Tests were performedon junctions with tall sleevesinstalled.

    Tip: Low top cap does notaccept any cables.

    Cables Testedå CommScope Systimax Gigaspeed 1071E Series Category 6 Cable OD=0.23"

    ∫ CommScope Systimax X10D 1091B Series Category 6A Cable OD=0.285"

    Power harnessesreduce cable capacity.An average of 10-15 cableswill be reduced per harnessused. However, this numbervaries according to installa-tion practices and the type ofcables used.

    If glass window is usedat the top of a panel,top cap lay-in cable capacityis 20 for category 6 cables.

    When laying cablesvertically behind skins,capacity is dependent onskin width.

    When using stackingjunctions, the fork con-nector does not reducecable capacity.

    å ∫

    L, T, X, V, and Y Horizontal RoutingLay-in cable routing at top of 25 20panels in L or V configuration Hi Hi

    Lay-in cable routing at top of 30 25panels in T configuration Hi Hi

    Lay-in cable routing in top of 30 25panels in X or Y configuration Hi Hi

    Lay-in cable routing (around the 25 20corner) at the top of a panel in Hi HiT or X configuration

    å ∫

    L, T, X, V, and Y Horizontal RoutingLay-in cable routing (corner) at 12 10base of panel with power in L, T, or V configuration

    Lay-in cable routing (corner) at 32 20base of panel without power in L, T, or V configuration

    Lay-in cable routing (straight) at 12 10base of panel with power in X or Y configuration

    Lay-in cable routing (corner) at 12 10base of panel with power in X or Y configuration

    Lay-in cable routing (straight) at 32 25base of panel without power, or with power harness routed above in X or Y configuration

    Lay-in cable routing (corner) at 32 20base of panel without power, or with power harness routed above in X or Y configuration

    40 Kick Solutions Specification Guide

    August 2015

  • Wirin

    g a

    nd

    Ca

    blin

    g

    Cable Capacities

    ...............................................................................................................................................

    ...............................................................................................................................................

    å ∫

    Straight Horizontal RoutingLay-in cable routing at top of 30 25panel (in-line junction) Hi Hi

    Lay-in cable routing at base of 12 10panel with power

    Lay-in cable routing at base of 32 25panel without power or with power harness routed above

    å ∫

    Kick Solutions Specification Guide 41

    Straight Vertical RoutingVertical cable routing inside 28 18junction utility pole (used on Hi Hian end, L or T configuration an end)

    Vertical cable routing inside thin 28 18trim utility pole Hi Hi

    Vertical cable lay-in in a ceiling access lay-in utility package 28 182 directions Hi Hi

    Vertical cable lay-in in a ceiling 20 15access lay-in utility package Hi Hi1 direction

    Change in height (top) 13 9 Hi Hi

    Through center of X 24 16

    Tip: Low top cap does not accept any cables.

    August 2015

  • Powerway

    ...............................................................................................................................................

    ...............................................................................................................................................

    42 Kick Solutions Specification Guide

    Powerways that areinstalled in the panel basecavity allow power to be distributed wherever panelsgo. They are concealedwhen properly installed. Allfive wiring schematics areavailable.

    All the components inan electrical distribu-tion network must usethe same wiring schematic.Comp onents are colorcoded and keyed to make itimpossible to connect mis-matched parts.

    All Steelcase electri-cal systems are designedin compliance with theNational Electrical Code(NEC) and CanadianElectrical Code (CEC) tofunction as a multi-wirebranch circuit. Instal lationsshould be made in accor-dance with the NEC or CECprovisions for multi-wirebranch circuits.

    Local electrical codesvary. Consult a qualifiedelectrical contractor or engi-neer for the proper installa-tion of electrical equipment.Chicago, New York City, andLos Angeles have specialrequirements.

    Kick panels that are24"W use a double whippowerway with one greenend and one yellow endconnector.

    Receptacles snap intoterminals and are held inplace with screws.

    Green flag connector

    Terminal for basepower-in or larger-sizereceptacle.

    Yellow flagconnector

    Green flagconnector

    Power pole connects here and does not occupy a receptacle location.

    Terminal for standard-sized receptacle only.

    August 2015

  • Powerway

    Power can be routedthrough the base of panelsin a two- and three-panel,120° connection.

    2" x 2" power andcable poles can bringbuilding power and datafrom the ceiling to a 120°panel application at the endof a run or 90° connectiononly.

    90(inside measurement)

    120

    Application TopicsFactory included powerway for field instal-lation replaces need to orderseparate powerways.

    Field-installed power-ways can be orderedthrough Kick service parts.

    Wiring and CablingChicago, New YorkCity, and Los Angeleshave special requirements.

    UnderwritersLaboratory (UL) listed.These products have beendesigned to meet U.S. andCanadian national electricaland energy codes and mostlocal building codes. Localelectrical codes vary, soconsult with your localauthority having jurisdictionas they have final say