killeshal civil product range - kpckilleshalprecast.co.uk/.../ukroi-kpc-civil-product-range1.pdf ·...

Download Killeshal Civil Product Range - KPCkilleshalprecast.co.uk/.../UKROI-KPC-Civil-Product-Range1.pdf · :LL \Z VUSPUL!

If you can't read please download the document

Upload: lyhuong

Post on 06-Feb-2018

220 views

Category:

Documents


1 download

TRANSCRIPT

  • kilform

    Specials made to order

    civil product range

    JUNCTION BOXES ESB CCTV Eircom

    Services Lighting Risers

    DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways

    Headwalls

    ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully

    Gully Risers Cast Iron Free Flow Lids

    MARKER POSTS, SLABS AND PLATES Round Top Marker Post Flat Top Marker Post Square Head Marker Post Electrical Marker Post

    Duct Marker Post Duct Marker Blocks Hydrant and Water Plates Earth Rod Box

    MISCELLANEOUS Retaining Wall Blocks Lamp Post Base

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    JUN

    CT

    ION

    BO

    XE

    S

    REFERENCE SIZE MM A x B x C HOLES 4 WAY HOLES 3 WAY HOLES 2 WAYHOLES

    KNOCK OUTWEIGHT

    KG

    J/B 3 640 x 1110 x 800 535J/B 4 640 x 1110 x 800 646J/B 5 960 x 1270 x 895 1066J/B 9 440 x 590 x 400 90

    J/B 10 440 x 590 x 400 45J/B 11 420 x 540 x 220 46J/B 12 850 x 850 x 950 826J/B 15 890 x 1450 x 950 1215J/B 18 1150 x 1150 x 850 1046J/B 21 1150 x 1450 x 850 1200J/B 24 450 x 700 x 650 328J/B 25 1000 x 1600 x 1040 1515J/B 26 1290 x 1310 x 1150 1600J/B 27 1190 x 1210 x 870 1113J/B 28 740 x 1210 x 900 758J/B 29 740 x 1210 x 900 851J/B 30 1075 x 1150 x 1050 1155J/B 31 875 x 950 x 900 795J/B 33 800 x 1400 x 895 870J/B 34 1090 x 1110 x 1000 1088J/B 35 1075 x 1150 x 1050 838

    PAGE

    2

    JUNCTION BOXES

    STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply withEN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced.

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    JUN

    CT

    ION

    BO

    XE

    S

    PAGE

    3

    COLOUR CODE BURIED PLASTIC PIPING I.S. 370: 2007Electricity ducting

    Public lightingStreet furniture / signal below 125 Volt

    Gas pipeBuried potable water

    SewerStorm and road drain smooth external wall duct

    Storm and road drain corrugatedTelecom / fibre optic smooth external wall duct

    Telecom / fibre optic corrugated dUd only-Maximum pipe outside diameter 175 mm

    Any colourexcept

    Red or Yellow

    Reinforced walls. eircom approved. Easily knockout polystyrene cable entry

    point/can be supplied with 12/no x 150mmdia straight through entry points (4/no or1. no side wall, 4/no on each cable end).

    Easily manoeuvred with lifting eyes.

    Ref: eircom J/B 3

    eircom JUNCTION BOX 28 eircom JUNCTION BOX 29 740 x 1210 x 900mm 740 x 1210 x 900mm

    Ref: eircom J/B 4

    Other sizes availablecontact Killeshalscustomer service on

    Ref: eircom J/B 28 Ref: eircom J/B 29

    eircom JUNCTION BOX 3 eircom JUNCTION BOX 4 640 x 1110 x 800mm 640 x 1110 x 800mm

    Junction Boxes Section***Colour may very depend on application

    STANDARDS NOTICE:Killeshal Precast Services Boxes are manufactured to comply withEN1917:2004 Concrete manholes and inspection chambers unreinforced,steel fibre and reinforced.

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    PAGE

    4

    JUN

    CT

    ION

    BO

    XE

    S

    JUNCTION BOX 9 JUNCTION BOX 10 JUNCTION BOX 11 HEAVY DUTY VALVE CHAMBER

    440 x 590 x 400mm HEAVY DUTY VALVE CHAMBER

    440 x 590 x 200mm 420 x 540 x 220mm

    Ref: J/B 9 Ref: J/B 10 Ref: J/B 11

    JUNCTION BOX 12 JUNCTION BOX 15 JUNCTION BOX 18 JUNCTION BOX 21 MANHOLE BOX

    850 x 850 x 950mm MANHOLE BOX

    890 x 1490 x 950mm MANHOLE BOX

    1150 x 1150 x 850mm MANHOLE BOX

    1150 x 1450 x 850mm

    Ref: J/B 12 Ref: J/B 15 Ref: J/B 18 Ref: J/B 21

    Base Ref: J/B 23

    Frame Ref: J/B 22

    Frame Ref: J/B 19

    Base Ref: J/B 20

    Frame Ref: J/B 16

    Base Ref: J/B 17

    Frame Ref: J/B 13

    Base Ref: J/B 14

    Ref: J/B 9

    Ref: J/B 10

    ESB MINI PILLAR JUNCTION BOX 5 960 x 1270 x 895mm

    Ref: J/B 5***

    Reinforced walls. 100 mm shoulder to facilitate

    increasing the depth. Drainage Sump. Easily manoeuvred. Multiple cable entry points. Integrated, reinforced base.

    JUNCTION BOX 24 450 x 700 x 650mm

    Ref: J/B 24***

    ***Colour may very depend on application see page 2

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    PAGE

    5

    JUN

    CT

    ION

    BO

    XE

    S

    TABLE FOR J/B 25, J/B 26, J/B 27

    BLINDING AND EMBEDDING REQUIREMENTS IN ACCORDANCE WITH HD 25/95

    SUBGRAGE DBR%

    SUB-BASE THICKNESSMM

    EDGE DISTANCE FROM BOXTO EDGE BLINDING MM

    SUB-BASE MATERIAL

    >5 225 225 GRANULAR MATERIAL (TYPE2)

    5

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    JUN

    CT

    ION

    BO

    XE

    S

    PAGE

    6

    JUNCTION BOX 31 JUNCTION BOX 30 875 x 950 x 900mm 1075 x 1150 x 1050mm

    Ref: J/B 501

    Ref: J/B 30***

    JUNCTION BOX RISER J/B 501 JUNCTION BOX RISER J/B 502 875 x 950 x 150mm

    To suit: - J/B 31 - J/B 30

    1090 x 1110 x 100mmTo suit: - J/B 26 - J/B 27 - J/B 34 - J/B 35

    Ref: J/B 31***

    JUNCTION BOX 33 800 x 1400 x 895mm

    Ref: J/B 33***

    Ref: J/B 34***

    Ref: J/B 35***

    Ref: J/B 502***Colour may very depend on application see page 2

    For J/B 30 withoutbase see J/B 31

    High adjusting riserto suit see J/B 501

    For J/B 31 withbase see J/B 30

    High adjusting riserto suit see J/B 501

    JUNCTION BOX 35 1075 x 1150 x 1050mm

    For J/B 35 with base see J/B 27

    High adjusting riser to suit see J/B 502

    JUNCTION BOX 34 1090 x 1110 x 1000mm

    For J/B 34 with base see J/B 26

    High adjusting riser to suit see J/B 502

    For J/B 33 with base see J/B 25

    High adjusting riser to suit see J/B 502

    Riser if requiredfor high adjustment

    Riser if requiredfor high adjustment

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    PAGE

    7

    DU

    CT

    CH

    AN

    NE

    LS

    AN

    D C

    OV

    ER

    S

    DUCT CHANNEL 105 DUCT CHANNEL 108 370 x 490 x 610mm 215 x 285 x 915mm

    Ref: D/CH 105

    SPILLWAY CHANNEL 116 HEADWALLS 343 to 450 x 710 x 895 x 1000mm 1820 x 1037 x 2000mm

    DUCT COVERRef: D/C 173

    Ref: D/CH 108

    DUCT COVERRef: D/C 126

    DUCT CHANNEL 111 DUCT CHANNEL 117 350 x 765 x 1497mm 340 x 448 x 1000mm

    DUCT COVERRef: D/C 209

    Ref: D/CH 111

    DUCT CHANNEL 114 DUCT CHANNEL 115 170 x 440 x 1000mm 170 x 280 x 1000mm

    Ref: D/CH 115Ref: D/CH 114

    Ref: D/C 228

    GAS LINE COVER SLABS 1450 x 100mm 1450 x 150mm 1450 x 200mm

    Ref: D/C 199Ref: D/C 242

    Ref: D/CH 116

    Ref: D/CH 117

    Ref: M/127

    Other sizes availablecontact Killeshalscustomer service on

    DUCT COVERRef: D/C 260

    DUCT COVERRef: D/C 262

  • The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    PAGE

    8

    UNTRAPPED GULLY UNTRAPPED GULLY (800x380x445mm)

    Ref: G/1Ref: G/1 + G/R 104 + C/250 (G/9)Ref: G/1 + G/R 104

    TRAPPED GULLY TRAPPED GULLY (800x500x375mm)

    Ref: G/2 Ref: G/2 + G/R 104Ref: G/2 + G/R 104 + C/250 (G/9)

    LARGE TRAPPED GULLY LARGE TRAPPED GULLY (805x585x450mm)

    Ref: G/5 G/R 103 + C/250 (G/9)Ref: G/5 + Ref: G/5 +

    G/R 102 + C/400 (G/10)

    RO

    AD

    GU

    LLY

    AN

    D L

    IDS

    GULLY RISERS 970x970x85mm 750x650x100mm

    To suit:- G/5

    750x650x100mmTo suit:- G/5

    610x610x100mmTo suit:- G/1- G/2

    CAST IRON FREE FLOW LIDS 527x527x100mm

    To suit:- G/5

    515x395x75mmTo suit:- G/1- G/2- G/5

    Ref: G/R 102 Ref: G/R 104Ref: G/R 103 Ref: D/400 (G/10) Ref: D/250 (G/9)Ref: G/R 101

  • PAGE

    9

    ELECTRICAL (180x50x935mm)

    MARKER POSTS AND SLABS marker posts are placed at or behind location points for services such as

    AV/SV, hydrant chambers, water and gas chambers, electric cable junctions andfield markers as markers for emergency services or service engineers

    buried hazard warning marker slabs which shadow electricity lines andgas pipes, helping to avoid breaches and health and safety incidents

    Ref: M/POST 105

    For Line Drainage See Pre-Fabricated Drainage System Catalogue

    PLATES HYDRANT PLATES WATER PLATES

    The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.

    MA

    RK

    ER

    PO

    ST

    S &

    PLA

    TE

    S

    Ref: M/POST 113 Ref: M/POST 114 Ref: M/POST 115

    RETAINING WALL BLOCKS LAMP POST BASE 1400 x 695 x 795mm 700 x 700 x 700mm

    * 1200 x 1200 x 1200mm also available

    Ref: M/112 Ref: IR/11

    MIS

    CE

    LLA

    NE

    OU

    S

    DUCT MARKER BLOCK(300x300x225mm)

    DUCT MARKER BLOCK(300x300x225mm)

    DUCT MARKER BLOCK(300x300x225mm)

    EARTH ROD BOX(325x325x150mm)

    Ref: M/123

    *Made to suit each individual requirements *Full range of plates available

    ROUND TOP(300x100x1090mm)*Plates see below

    FLAT TOP(270x80x1220mm)*Plates see below

    SQUARE HEAD(75x100x1230mm)*Plates see below

    DUCT(110x140x1600mm)

    Ref: M/POST 101 Ref: M/POST 102 Ref: M/POST 111Ref: M/POST 116

  • R . I OFFICETel: +353 (0)57 9353018

    Email: [email protected]: killeshal.com

    UK OFFICETel: 0800 0393367

    Email: [email protected]: killeshalprecast.co.uk