Kinetic Temperature Retrievals from MGS TES Bolometer Measurements:
Current Status and Future Plans
A.A. Kutepov, A.G. Feofilov, L.Rezac
July 28, 2009, NASA GSFC
![Page 2: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/2.jpg)
Outline
• Theoretical approach, algorithm
• Application to real retrievals: problems.
• Methods of solution: separating detectors, re-calibration, etc
• Other possible methods
• Conclusions and future plans
![Page 3: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/3.jpg)
Thermal Emission Spectrometer on MGS Satellite
Spectrometer• Michelson interferometer; spectral range: 1700 – 200 cm-1 (6 – 50 m); spectral sampling: ~5 or ~10 cm-1
Bolometer• Bolometric thermal radiance channel (5.1 – 150 m)• Solar reflectance channel (0.3 – 2.9 m)• Spectral range: 5.1 – 150 m• Tangent heights range: 0~100 km• Single detector FOV: 13 km, however:• 3x2 array of detectors scanned in overlapping steps provide 1-5 km vertical resolution
Array ofdetectors
![Page 4: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/4.jpg)
Bolometric instrumental functionand contributions to signal
![Page 5: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/5.jpg)
Non-LTE in CO2: vibrational temperatures
![Page 6: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/6.jpg)
Forward Radiative Transfer
modelFeedback scheme:
T’(z) = F{Imeas(z), Isimul(z)}
Corrected T(z)
P0 from TES SpectrometerInitial guess for T(z)
Iterations
Non-LTE model
Measured radiance I(z)
Imeas(z) ~ Isimul(z) ?Retrieved T(z)
CO2 populations
I simul(z
)
Imeas(z)
Forward fitting algorithm
![Page 7: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/7.jpg)
Numerical simulation of retrieval process
![Page 8: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/8.jpg)
Real life
• Daytime signal has an unknown pedestal. Moreover, 10m radiance is non-thermal. Considering only nighttime retrievals.
• Straightforward interpretation of nighttime bolometric data produces unrealistic data.
• Calibration of TES bolometer using integrated TES spectrometer.
• Even re-calibrated TES bolometer radiances do not lead to temperature retrievals that would qualitatively agree with the current understanding of Martian atmosphere’s physics.
• Illustrations of these issues will follow.
![Page 9: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/9.jpg)
Examples of day- and nighttime bolometric signals
![Page 10: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/10.jpg)
Day- and nighttime simulations
![Page 11: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/11.jpg)
Very first nighttime temperature retrievals. Ls=0.
![Page 12: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/12.jpg)
Possible reasons?
• Non-LTE issues: not important below ~80km altitude.• Atomic oxygen or KV-T(CO2-O) rate: can not change the signal at 50-60km to be 2-3 times larger while the radiance from 100km remains negligible.• Insufficient number of levels and transitions: tested.• Line parameters uncertainties: this is very unlikely for the fundamental bands.• Offsets in P0 leading to changes in P(z): varied by ~30%, didn’t help.• Possible signal issues: - twilight/night: only “pure night” cases selected - sporadic spikes: filtered out - differences between detectors (gain, latitudinal coverage): checked. Even if we take the “best” detector, it doesn’t help. - absolute values verification: need extra source of information.
![Page 13: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/13.jpg)
Spectral TES as a reference dataset for calibration
Average of the above
Average of the above
![Page 14: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/14.jpg)
Bolometer Spectrometer conversion (by M.Smith)
We are interested in this part
![Page 15: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/15.jpg)
Bolometer Spectrometer conversion tables
![Page 16: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/16.jpg)
Bolometer Spectrometer conversion tables
![Page 17: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/17.jpg)
“Best achievement”: temperature distribution for Ls=0
![Page 18: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/18.jpg)
Comparing with other measurements
TES Spectrometer
Ls=0
MCS Ls=330
![Page 19: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/19.jpg)
Even less realistic: temperature distribution for Ls=90
![Page 20: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/20.jpg)
Reasons for retrieving increased T
![Page 21: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,](https://reader036.vdocument.in/reader036/viewer/2022070418/5697c0111a28abf838ccbdf8/html5/thumbnails/21.jpg)
Possible ways of solving the problem
• Continue further attempts of re-calibrating bolometer.
• Switch to spectrometer and work with integrated signal.
Questions:
• What do we call an “integrated spectrometer”?
• Will the integrated spectrometer go above 60km?
• How good are MGS TES limb retrievals compared to retrievals from nadir observations?