kiss 4u kt5520 en50155 environmental report
DESCRIPTION
KISS 4U KT5520 EN50155 Environmental ReportTRANSCRIPT
-
Trade Register Straubing HRB 9302 V.A.T. DE 131457658 Information pursuant to Section 2(1) DL-InfoV (Germany) at www.tuev-sued.com/imprint
Managing Director: Johann Roidt
Phone: +49 9421 55 22-0 Fax: +49 9421 55 22-99 www.tuev-sued.de/senton
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Prfbericht / Test Report Nr. / No. 11383-02574-2 (Edition 1)
Auftraggeber Applicant
Kontron Embedded Computers GmbH
Gerteart Type of equipment
Computer System
Typenbezeichnung Type designation
KISS 4U 5520
Auftragsnummer / Order No.
45236015
Prfgrundlage Test standards
DIN EN 60068-2-1:2008-01 Cold DIN EN 60068-2-2:2008-05 Dry heat DIN EN 60068-2-27:2010-02 Shock DIN EN 60068-2-30:2006-06 Damp heat, cyclic
DIN EN 60068-2-64:2009-04 Vibration, broad-band rando
DIN EN 50155:2008-03 Railway applications - Electronic equipment used on rolling stock; sections 12.2.3, 12.2.4, 12.2.5, 12.2.9, 12.2.11 DIN EN 61373:1999-11 Railway applications - Rolling stock equipment - Shock and vibration tests sections 8, 9 and 10
October 12, 2010
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 2 of 42
Summary
Prfergebnisse / Test Results Auftragsnummer / Order No.
45236015
Die Prfungen wurden nach folgenden Vorschriften durchgefhrt: Tests were performed according to:
DIN EN 60068-2-1:2008-01 Cold
DIN EN 60068-2-2:2008-05 Dry heat
DIN EN 60068-2-27:2010-02 Shock
DIN EN 60068-2-30:2006-06 Damp heat, cyclic
DIN EN 60068-2-64:2009-04 Vibration, broad-band random
DIN EN 50155:2008-03 Railway applications - Electronic equipment used on rolling stock; sections 12.2.3, 12.2.4, 12.2.5, 12.2.9, 12.2.11
DIN EN 61373:1999-11 Railway applications - Rolling stock equipment - Shock and vibration tests sections 8, 9 and 10
Durchgefhrte Prfung
Test performed
Betriebsart
Operation mode
Prfergebnis
Testresult
Betrieb Operating
Transport/ Lagerung Transport/ Storage
Erf
llt
Pa
sse
d
Nic
ht
erf
llt
Not
Pa
sse
d
Klte / Cold
Trockene Wrme / Dry Heat
Feuchte Wrme, zyklisch / Damp Heat, cyclic
Breitbandrauschen / Broadband Random
Isolationsprfung / Insulation Test
Schock / Shock
Bemerkungen / Remarks: The final evaluation will be performed by the applicant.
Die Prfergebnisse beziehen sich ausschlielich auf das zur Prfung vorgestellte Prfmuster. Ohne schriftliche Genehmigung des Prflabors darf der Prfbericht auszugsweise nicht vervielfltigt werden. The test results relate only to the individual item which has been tested. Without the written approval of the test laboratory this report may not be reproduced in extracts.
Datum / Date Geprft von / Tested by Freigabe durch / Checked by Prfergebnis / Test Result
Erfllt / Passed
Nicht erfllt / Not passed
October 12, 2010
Reinhold Markl Responsible for testing
Johann Roidt Laboratory manager
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 3 of 42
Table of Contents
1 Administrative Data ................................................................................................................... 4
2 Details about the Test Laboratory ............................................................................................. 5
3 Description of the Equipment Under Test .................................................................................. 6
3.1 Photos of theTestsample .................................................................................................... 7
4 Operation Mode and Configuration of EUT ............................................................................... 9
5 Performance Criteria and Methods of Observation .................................................................. 11
6 Referenced Regulations .......................................................................................................... 12
7 Test Results ............................................................................................................................ 13
7.1 Climatic Tests ................................................................................................................... 18
7.2 Mechanical Tests.............................................................................................................. 23
8 Revision History ...................................................................................................................... 42
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 4 of 42
1 Administrative Data
Application details
Applicant: Kontron Embedded Computers GmbH Oskar-von-Miller-Strae 1 85386 Eching
Contact person: Mr. Ferit Durgut
Order number: 45236015 / 02.08.2010
Receipt of EUT: August 4, 2010
Return of EUT: --
Date(s) of test: September 8 to 16, 2010
Note(s): The final evaluation will be performed by the applicant.
Responsible for testing: Mr. Reinhold Markl
Responsible for test report: Mr. Reinhold Markl (sw)
Test report checked by: Mr. Johann Roidt
Report details
Report number: 11383-02574-2
Edition: 1
Issue date: October 12, 2010
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 5 of 42
2 Details about the Test Laboratory
Details about the Test Laboratory
Company name: TV SD SENTON GmbH
Address: uere Frhlingstrae 45 D-94315 Straubing Germany
Laboratory accreditation: DAR-Registration No. DAT-PL-171/94-03
Contact: Mr. Johann Roidt Phone: +49 9421 5522-0 Fax: +49 9421 5522-99
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 6 of 42
3 Description of the Equipment Under Test
Equipment characteristics
Type designation: KISS 4U 5520
Parts of the system: --
Options and accessories: --
Type of equipment: Computer System
Serial number: MB-SN: 9013000175 Housing-SN: X4S40E33A11XXXXXXP
Manufacturer: Kontron Embedded Computers GmbH
Power supply: AC supply Nominal: 230 V
Nominal frequency: 50 Hz
Version of EUT: see photo, series version
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 7 of 42
3.1 Photos of theTestsample
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 8 of 42
Testprogram
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 9 of 42
4 Operation Mode and Configuration of EUT
Operation Mode(s)
PC burn in testprogram created by the applicant.
List of ports and cables
No. Description Classification1 Cable type Cable length
A1 Power supply I ac power Unshielded 2 m
A2 Power supply II ac power Unshielded 2 m
S1 Com 1 signal/control port -- --
S2 VGA signal/control port Shielded 2 m
S5 USB 1 (keyboard) signal/control port Shielded 2 m
S6 USB 2 (mouse) signal/control port Shielded 2 m
EUT mounting
No. Description Type designation Serial no. or ID Weight
1 clamped down to mounting area (see photos)
4 M8 screws on mounting plate
--
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 10 of 42
List of support devices
No. Description Type designation Serial no. or ID Weight
1 steel pipes, metric bolts, cross bars
steel -- appr. 5 kg
2 mounting plate 850 x 850 x 30 aluminium appr. 55 kg
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 11 of 42
5 Performance Criteria and Methods of Observation
Methods of Observation
Function Observed size Permissible range Observation method
mechanical constitution -- visual
functional test burn in testprogram no error entries no interruption of communication
PC burn in testprogram
The final evaluation will be done by the applicant.
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 12 of 42
6 Referenced Regulations
Publikation Titel
DIN EN 60068-1:1995-03 Environmental testing - Part 1: General and guidance (IEC 60068-1:1988 + Corrigendum 1988 + A1:1992); German version EN 60068-1:1994
DIN EN 60068-2-1:2008-01 Environmental testing - Part 2-1: Tests - Test A: Cold (IEC 60068-2-1:2007); German version EN 60068-2-1:2007
DIN EN 60068-2-2:2008-05 Environmental testing - Part 2-2: Tests - Test B: Dry heat (IEC 60068-2-2:2007); German version EN 60068-2-2:2007
DIN EN 60068-2-27:2010-02 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock (IEC 60068-2-27:2008); German version EN 60068-2-27:2009
DIN EN 60068-2-30:2006-06 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) (IEC 60068-2-30:2005); German version EN 60068-2-30:2005
DIN EN 60068-2-47:2006-03 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests (IEC 60068-2-47:2005); German version EN 60068-2-47:2005
DIN EN 60068-2-64:2009-04 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance (IEC 60068-2-64:2008); German version EN 60068-2-64:2008
DIN EN 50155:2008-03 Railway applications - Electronic equipment used on rolling stock; German version EN 50155:2007
DIN EN 61373:1999-11 Railway applications - Rolling stock equipment - Shock and vibration tests (IEC 61373:1999); German version EN 61373:1999
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 13 of 42
7 Test Results
Climatic Tests - Operated
DIN EN 60068-2-1 Cold
Operation Mode OPERATION
Test performed Test Result Note
temperature 0 C Test passed
testsample switched off during test,
functional test at the end of cold phase
dwell time 12 h
slew rate 1 K/min
aftercare 1 h
DIN EN 60068-2-2 Dry Heat
Operation Mode OPERATION
Test performed Ba Test Result Note
temperature +55 C Test passed
testsample switched on during complete
testtime dwell time 5 h
temperature without ventilation +70 C
dwell time 4 h
slew rate 1 K/min
aftercare 1 h
DIN EN 60068-2-30 Damp Heat, cyclic
Operation Mode OPERATION
Test performed Db, variant 1 Test Result Note
TB upper temperature +55 C Test passed
testsample switched off during first cycle,
and switched on at the beginning of the
second cycle
dwell time 24 h
number of cycles 2
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 14 of 42
Insulation/High VoltageTest
EN 50155:2008-03 clause 12.2.9
Operation Mode NON OPERATION
Test performed Test Result Note
temperature RT Test passed
preconditioning damp heat, cyclic test time 60 s per teststep
testvoltage insulation 500 V DC *1)
Testvoltage AC not possible alternative DC testing performed
testvoltage high voltage 1500 V AC *1
2130 V DC 3000 V AC
*1
4250 V DC
see table
Primary Circuit Power Supply 1 and 2
Secondary Circuit VGA
COM
Audio
LAN
PS2
USB
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 15 of 42
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 16 of 42
ISO 500V DC 60s
Primary Circuit Housing Secondary Circuit
Primary Circuit
Housing 100 MOhm
Secondary Circuit 100 MOhm na
HV 1500 V AC 2130 V DC 60s
Primary Circuit Housing Secondary Circuit
Primary Circuit
Housing OK
Secondary Circuit OK na
HV 3000 V AC 4250 V DC 60s
Primary Circuit Housing Secondary Circuit
Primary Circuit
Housing OK
Secondary Circuit OK na
ISO 500V DC 60s
Primary Circuit Housing Secondary Circuit
Primary Circuit
Housing 100 MOhm
Secondary Circuit 100 MOhm na
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 17 of 42
Mechanical Tests Operated
DIN EN 60068-2-64 Random Vibration
DIN EN 50155 section 12.2.11 functional test
Operation Mode OPERATION
Test performed cat 1 class A Test Result Note
RMS level vertical horizontal
0,75 m/s 0,5 m/s
Test passed
X / Y / Z tested
duration 10 min
DOF2 120
standard deviation 3
DIN EN 60068-2-64 Random Vibration
DIN EN 50155 section 12.2.11 endurance test
Operation Mode NOT IN OPERATION
Test performed cat 1 class A Test Result Note
RMS level vertical horizontal
5,9 m/s 3,9 m/s
Test passed
X / Y / Z tested functional test before and
after the test
duration 300 min
DOF3 120
standard deviation 3
DIN EN 60068-2-27 Single Shock
DIN EN 50155 section 12.2.11 Shock
Operation Mode OPERATION
Test performed cat 1 class A Test Result Note
shock acceleration 50 m/s Test passed
X / Y / Z tested
with the parameters for longitudinal shock
shock duration 30 ms
count of shocks 3 per axis and direction
pulse shape half-sine pulse
2 degree of freedom 3 degree of freedom
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 18 of 42
7.1 Climatic Tests
7.1.1 Test Equipment List
Type Designation Inv.-no. Manufacturer
Vibration- and temperature-
/climatic test chamber
TIRAvibro TTV 7120 ES VH
1934 TIRA GmbH
Software WINKRATOS 1935 TIRA GmbH
Thermal Shock test chamber TSK 200 / 3416/05 2006 Feutron GmbH
Software FKS Wincontrol v2.0.1.0 akrobit Software GmbH
Temperature-/climatic test
chamber
KPK200 / 3433/16 2005 Feutron GmbH
Software FKS Wincontrol v2.0.1.0 akrobit Software GmbH
Temperature-/climatic test
chamber
KPK200 / 3433/16 2008 Feutron GmbH
Software FKS Wincontrol v2.0.1.0 akrobit Software GmbH
Temperature-/climatic test
chamber
WK11-340 1702 Weiss Umwelttechnik GmbH
Software SimPati 1702 Weiss Umwelttechnik GmbH
Temperature test chamber HT 4010 1271 Heraeus Vtsch GmbH
Software SimPati 1702 Weiss Umwelttechnik GmbH
Data Aquisition Switch Unit 34970A 1967 Agilent Technologies
20 channel multiplexer 34901A 1968 Agilent Technologies
High Voltage Tester KT 3881H 1940 SPS electronic GmbH
Software 3332Dat 1960 SPS electronic GmbH
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 19 of 42
7.1.2 Testsetup
Operating / Not Operating
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 20 of 42
7.1.3 Cold
Testprotocols
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 21 of 42
7.1.4 Dry Heat
Testprotocols
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 22 of 42
7.1.5 Damp Heat, cyclic
Testprotocols
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 23 of 42
7.2 Mechanical Tests
7.2.1 Test Equipment List
Type Designation Inv.-no. Manufacturer
Shakersystem TIRA GmbH
Shaker S597/AIT-340 1923 TIRA GmbH
Power amplifier A 54342 1923 TIRA GmbH
Sliptable TGT MO 20 XL 1923 TIRA GmbH
4-channel - controlsystem VR 8500-4 1924 Vibration Research
Software Vibration View 1925 Vibration Research
Accelerometer M320 C 03 1927 ICP
Accelerometer M320 C 33 2049 ICP
Triaxial Accelerometer M356A02 2046 ICP
Triaxial Accelerometer M356A15 1930 ICP
Accelerometer M352 C 22 2047 ICP
Accelerometer M352 C 22 2048 ICP
Accelerometer M352 C 22 2050 ICP
Vibration- and temperature-
/climatic test chamber
TIRAvibro TTV 7120 ES VH
1934 TIRA GmbH
Software WINKRATOS 1935 TIRA GmbH
Data Aquisition Switch Unit 34970A 1967 Agilent Technologies
20 channel multiplexer 34901A 1968 Agilent Technologies
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 24 of 42
7.2.2 Testsetup
Testsetup X-Axis
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 25 of 42
Testsetup Y-Axis
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 26 of 42
Testsetup Z-Axis
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 27 of 42
7.2.3 Random Vibration Functional Test
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 28 of 42
X-Axis
5 10 100-73x10
-44x10
-61x10
-51x10
-41x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 2 4 6 8 10 120.005
0.080
0.010
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 7.998e-005 0 20 Hz 7.998e-005 -6 150 Hz 1.442e-006
Test level schedule:
Duration Level 1) 0:10:00 100 % ** Test started Sep 07, 2010 16:15:16, running for 0:10:43 ** Current level: 1, running at 100 % for 0:10:00 of 0:10:00
Measurements: Demand: 0.05099 G RMS 0.7039 mm pk-pk Control: 0.0512 G RMS 0.6454 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 29 of 42
Y-Axis
5 10 100-73x10
-44x10
-61x10
-51x10
-41x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 2 4 6 8 10 120.005
0.080
0.010
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 7.998e-005 0 20 Hz 7.998e-005 -6 150 Hz 1.442e-006
Test level schedule:
Duration Level 1) 0:10:00 100 % ** Test started Sep 08, 2010 09:08:00, running for 0:10:39 ** Current level: 1, running at 100 % for 0:10:00 of 0:10:00
Measurements: Demand: 0.05099 G RMS 0.7039 mm pk-pk Control: 0.05134 G RMS 0.6481 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 30 of 42
Z-Axis
5 10 100-77x10
-48x10
-61x10
-51x10
-41x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 2 4 6 8 10 12
0.200
0.010
0.100
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 0.00018 0 20 Hz 0.00018 -6 150 Hz 3.244e-006
Test level schedule:
Duration Level 1) 0:10:00 100 % ** Test started Sep 08, 2010 16:29:31, running for 0:10:43 ** Current level: 1, running at 100 % for 0:10:00 of 0:10:00
Measurements: Demand: 0.07648 G RMS 1.056 mm pk-pk Control: 0.07696 G RMS 0.9798 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 31 of 42
7.2.4 Random Vibration Endurance Test
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 32 of 42
X-Axis
5 10 100-52x10
-23x10
-41x10
-31x10
-21x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 50 100 150 200 250 300 3500.07
5.00
0.10
1.00
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 0.004866 0 20 Hz 0.004866 -6 150 Hz 8.771e-005
Test level schedule:
Duration Level 1) 5:00:00 100 % ** Test started Sep 07, 2010 16:28:27, running for 5:01:00 ** Current level: 1, running at 100 % for 5:00:00 of 5:00:00
Measurements: Demand: 0.3977 G RMS 5.49 mm pk-pk Control: 0.3947 G RMS 5.188 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 33 of 42
Y-Axis
5 10 100-52x10
-23x10
-41x10
-31x10
-21x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 50 100 150 200 250 300 3500.07
5.00
0.10
1.00
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 0.004866 0 20 Hz 0.004866 -6 150 Hz 8.771e-005
Test level schedule:
Duration Level 1) 5:00:00 100 % ** Test started Sep 08, 2010 09:23:22, running for 5:00:59 ** Current level: 1, running at 100 % for 5:00:00 of 5:00:00
Measurements: Demand: 0.3977 G RMS 5.49 mm pk-pk Control: 0.3922 G RMS 5.089 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 34 of 42
Z-Axis
5 10 100-54x10
-25x10
-41x10
-31x10
-21x10
Frequency (Hz)
Accele
ration (
G/
Hz)
Acceleration Profile
Demand
Control
0 50 100 150 200 250 300 350
0.700
0.010
0.100
Time (Min)
Accele
ration (
G)
Acceleration vs Time
Demand
Control
A-2049
Breakpoint table:
Frequency G/Hz dB/Octave 5 Hz 0.01114 0 20 Hz 0.01114 -6 150 Hz 0.0002007
Test level schedule:
Duration Level 1) 5:00:00 100 % ** Test started Sep 08, 2010 16:46:28, running for 5:01:23 ** Current level: 1, running at 100 % for 5:00:00 of 5:00:00
Measurements: Demand: 0.6016 G RMS 8.306 mm pk-pk Control: 0.5967 G RMS 7.828 mm pk-pk
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 35 of 42
7.2.5 Shock
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 36 of 42
X-Axis positive
-150 -100 -50 0 50 100 150 200-4
-2
0
2
4
6
8
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-10
-5
0
5
10
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 08, 2010 08:06:57 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 5 G (Positive) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 4.912 G Output voltage: 2.658 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 37 of 42
X-Axis negative
-150 -100 -50 0 50 100 150 200-8
-6
-4
-2
0
2
4
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-10
-5
0
5
10
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 08, 2010 08:05:19 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 5 G (Negative) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 4.974 G Output voltage: 2.611 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 38 of 42
Y-Axis positive
-150 -100 -50 0 50 100 150 200-4
-2
0
2
4
6
8
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-10
-5
0
5
10
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 08, 2010 15:29:13 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 5 G (Positive) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 4.939 G Output voltage: 3.025 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 39 of 42
Y-Axis negative
-150 -100 -50 0 50 100 150 200-8
-6
-4
-2
0
2
4
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-10
-5
0
5
10
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 08, 2010 15:31:29 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 5 G (Negative) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 4.913 G Output voltage: 2.961 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 40 of 42
Z-Axis positive
-150 -100 -50 0 50 100 150 200-2
-1
0
1
2
3
4
5
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-6
-4
-2
0
2
4
6
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 09, 2010 08:03:38 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 3.059 G (Positive) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 3.023 G Output voltage: 1.734 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 41 of 42
Z-Axis negative
-150 -100 -50 0 50 100 150 200-5
-4
-3
-2
-1
0
1
2
Time (ms)
Accele
ration (
G)
Acceleration
Demand
Control
-150 -100 -50 0 50 100 150 200-6
-4
-2
0
2
4
6
Time (ms)
Dis
pla
cem
ent
(mm
)
Displacement
DemandControl
Test level schedule:
Pulses Level 1) 3 100 % ** Test started Sep 09, 2010 08:04:56 ** Current level: 1, running at 100 % for 3 of 3 pulses
Test Profile: 30 ms Half Sine Pulse with amplitude 3.059 G (Negative) Pre-pulse amplitude: 20 % of the peak acceleration Post-pulse amplitude: 20 % of the peak acceleration Normal limits used
Control channels: A-2049
Measurements: Control amplitude: 3.051 G Output voltage: 1.727 Volts peak
-
TV SD SENTON GmbH uere Frhlingstrae 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 11383-02574-2 (Edition 1) Page 42 of 42
8 Revision History
Revision History
Edition Date Issued by Modifications
1 October 12, 2010 Reinhold Markl (sw)
First Edition