kl professional led_catalogue

Download Kl professional led_catalogue

If you can't read please download the document

Upload: kaspers-lighting-international-bv

Post on 20-May-2015

1.076 views

Category:

Business


3 download

DESCRIPTION

Professional LED Cata

TRANSCRIPT

  • 1. Professional LED Catalogue

2. Products WAVE AVENUE2 CURVE DARKCITY GARDEN GLOBO CRETA MALTASATURN MOON TUBE DELCAR81824 38 44505662687480 86 92 98 TECH 28 3. Street Lighting WAVE Photovoltaic WAVE Mathematical beauty 4. Street Lighting WAVE Polar Diagram A - Wave 37 Polar Diagram B - Wave 37 APPLICATIONS Street Lighting cd/klmcd/klm PAINTING CYCLEC0 - C180 C90 - C270 C0 - C180 C90 - C270Sandblasting, cataphoresis and painting withAccessories Polar Diagram A - Wave 74 Polar Diagram B - Wave 74 polyester powders. COLOURS KM-w-OR KM-w-TPRAL 7024Optional: (For orders >50 pc.) cd/klmcd/klmRAL 9003 C0 - C180 C90 - C270 C0 - C180 C90 - C270 RAL 9005Technical Drawing730 mmOPTIONALFLOw MODELPOwERFLOw FLOw(Neutral white)146 mm(Cool white) (warm white)w37L 51w 5020Lm 5020Lm 3850Lm w37M 75w 6790Lm 6790Lm 5210Lm 288 mm720 mm w37H108w 8830Lm 8830Lm 6770Lm w74L 87w 8550Lm 8550Lm 6560Lm8157 mmw74M128w11570Lm 11570Lm8870Lm w74H184w15060Lm 15060Lm 11540Lm 5. Street Lighting WAVEGENERAL FEATURESPHYSICAL AND MECHANICAL FEATURESSingle body. Die cast aluminium. wide finned surface. Material ApplicationsStreet lighting Securing frame and sectionning flip in ABS.ScrewsStainless SteelAsymmetrical street lighting lens (IESNA type II, full cut-off) ScreenPMMA LensSystem of lens with high precision collimators employed for the concentration of the luminous beam Strength against impactsIK 08 Neutral white: Power LEDRAL 7024 NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LEDColour of the fixture Optional: (For orders >50 pc.) EN 13032 REMOTE CONTROL(ww) Power LED RAL 9005 RAL 9003 (Measurement and presentation of photometric data for lamps An assigned micro device andSandblasting, cataphoresis and painting with polyester and luminaries) Painting process a firmware employed for the powders Pendency of the fixture -15, - 10, - 5, 0, + 5 + 10 + 15 EN 60529 transmission of data; Dimensions (l x h x p)720 x 170 x 290 mm(Specification for degrees of contained in the fixture; protection provided by enclosures) formed of radio receiver or powerline communication:Neutral white: 4.000K - 5.300Kweight8.0 kgEN 50102 - Remote control andColour temperature(Degrees of protection provided adjustment of the total Optional: Cw (Cool white) 5.300K - 10.000K1 piece per box.by enclosures for electrical luminous flux emitted by theww (warm white) 2.600K - 3.700K Case in shaped polystyrene, inside the carton.equipment against external Packaging fixture from 0 to 100% either Dimensions of box (l x h x p): 795 x 205 x 350 mmmechanical impacts) manually via specializedweight = 8.3 kg Chromatic Rendering EN 60598 circuits or following 70 < Ra < 80 (Ra= 2A)21 boxes on the euro pallet. Index (CRI) PalletDimensions of pallet (l x h x p) : 1200 x 1800 x 800 mm(Luminaries and accessories) adjustable timetables; - Instantaneous calculation weight = 180 kgEN 62031 of the amount of energy (LED modules for general lighting. consumed;Safety specifications) - Measurement of theLaser Safety Category 1M functionning temperature at EN 61347 the welding point of the LEDs (Lamp control gear. and the related alarms;General and safety requirements) On pole diam. 60 - 70 - 76 mm (accessorized)ELECTRICAL FEATURES - Evaluation of the MountingOn bracket diam. 60 mm functionning state (active or EN 61000 On bracket diam. 70 - 76 mm (accessorized)Power supply90 - 260 V a.c. / 50 - 60Hz(Harmonic current emissions) damaged) and the deriving alarms; EN 55015 - Measurement of workingBallastsElectronic, integrated in the fixture, with >85% efficiency(Limits and methods of Efficiency hours; > 90 Lm/w measurement of radio disturbance of the luminous source Protection against characteristics of electrical tension/current/with auto recovery (IEC 62384 compliant) lighting and similar equipment) temperature variations s.on < 1 s - s.off < 1 sEN 61547 Switch on/ offIsolation categoryII(Equipment for general lighting (instantaneous ignition/ deactivation)purposes - EMC immunity Protection degree requirements) Lens space: IP66 (optical interval - power Ballasts space: IP66 supply interval) Emissions Absent of IR and UV radiations w37L / w74L: 350mA LED modules powered with w37M / w74M: 500mA constant current (If) w37H / w74H: 700mA w37L: 58ww74L : 87w Toxic, inorganic elements AbsentNominal power w37M: 75ww74M : 128w w37H: 108w w74H : 184wPower factor (PF) PF = 0,97 (PFC active)10 Life span 50.000 h (decrease of the luminous flow: 30%) 6. Photovoltaic WAVE Polar Diagram - Wave 24 APPLICATIONS Street Lighting cd/klm PAINTING CYCLEC0 - C180 C90 - C270 Sandblasting, cataphoresis and painting withAccessories polyester powders. COLOURS KM-w-ORKM-w-TPRAL 7024Optional: (For orders >50 pc.) RAL 9003 RAL 9005Technical Drawing730 mm146 mm 288 mm720 mmOPTIONALFLOw MODELPOwERFLOw FLOw(Neutral white)(Cool white) (warm white) 12157 mmw24L 28w 2740Lm 2740Lm 2100Lm w24M 43w 3700Lm 3700Lm 2840Lm 7. Photovoltaic WAVEGENERAL FEATURESPHYSICAL AND MECHANICAL FEATURESSingle body. Die cast aluminium. wide finned surface. Material ApplicationsStreet lighting Securing frame and sectionning flip in ABS.ScrewsStainless SteelAsymmetrical street lighting lens (IESNA type II, full cut-off) ScreenPMMA LensSystem of lens with high precision collimators employed for the concentration of the luminous beam Strength against impactsIK 08 Neutral white: Power LEDRAL 7024NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LEDColour of the luminary Optional: (For orders >50 pc.)EN 13032 REMOTE CONTROL(ww) Power LED RAL 9005 RAL 9003(Measurement and presentation ofphotometric data for lamps An assigned micro device andand luminaries) Sandblasting, cataphoresis and painting with polyester a firmware employed for the Painting process powders EN 60529 transmission of data; Pendency of the fixture -15, - 10, - 5, 0, + 5 + 10 + 15 (Specification for degrees of contained in the fixture; Dimensions (l x h x p)720 x 170 x 290 mmprotection provided by enclosures) formed of radio receiver or powerline communication:Neutral white: 4.000K - 5.300K EN 50102 weight8.0 kg - Remote control andColour temperature (Degrees of protection provided adjustment of the total Optional: Cw (Cool white) 5.300K - 10.000K1 piece per box. by enclosures for electrical luminous flux emitted by theww (warm white) 2.600K - 3.700K Case in shaped polystyrene, inside the carton. equipment against external Packaging mechanical impacts) fixture from 0 to 100% either Dimensions of box (l x h x p): 795 x 205 x 350 mm manually via specializedweight = 8.3 kg Chromatic RenderingEN 60598 circuits or following 70 < Ra < 80 (Ra= 2A)21 boxes on the euro pallet. Index (CRI) (Luminaries and accessories) adjustable timetables;PalletDimensions of pallet (l x h x p) : 1200 x 1800 x 800 mm - Instantaneous calculation weight = 180 kg EN 62031 of the amount of energy(LED modules for general lighting. consumed; Safety specifications) - Measurement of theLaser Safety Category 1M functionning temperature atEN 61347 the welding point of the LEDs(Lamp control gear. and the related alarms; General and safety requirements) On pole diam. 60 - 70 - 76 mm (accessorized) - Evaluation of the MountingOn bracket diam. 60 mm functionning state (active orEN 61000 On bracket diam. 70 - 76 mm (accessorized)(Harmonic current emissions) damaged) and the deriving ELECTRICAL FEATURES alarms;EN 55015 - Measurement of workingEfficiency(Limits and methods of Power supply12 - 24 Volt d.c. hours; > 90 Lm/wmeasurement of radio disturbance of the luminous source characteristics of electrical BallastsIntegrated in the fixture, with >90% efficiency lighting and similar equipment)s.on < 1 s - s.off < 1 sProtection againstEN 61547 Switch on/ offtension/current/with auto recovery (IEC 62384 compliant)(Equipment for general lighting (instantaneous ignition/ deactivation) temperature variations purposes - EMC immunity requirements) Isolation categoryII Emissions AbsentProtection degree of IR and UV radiations Lens space: IP66 (optical interval - power Ballasts space: IP66 supply interval)LED modules powered withw24L: 350mA Toxic, inorganic elements Absentconstant current (If) w24M: 500mAw24L: 28w Nominal power w24M: 43w 14 Life span 50.000 h (decrease of the luminous flow: 30%) 8. Street Lighting AVENUE2 Historical projections 9. Street Lighting AVENUE2Polar Diagram APPLICATIONS Street Lightingcd/klm PAINTING CYCLE C0 - C180 C90 - C270Sandblasting, cataphoresis COLOURS Top block: Grey Ral 7035.Bottom block: Grey Ral 7036. Technical Drawing587 mm204 mm OPTIONAL60 mm FLOwMODELPOwERFLOw FLOw92 mm(Neutral white) (Cool white) (warm white) AV24L28w2740Lm 2740Lm2100LmAV24M41w3700Lm 3700Lm2840Lm288 mm AV24H59w4820Lm 4820Lm3700Lm18 AV40L46w4560Lm 4560Lm3500LmAV40M68w6170Lm 6170Lm4730Lm 10. Street Lighting AVENUE2GENERAL FEATURESPHYSICAL AND MECHANICAL FEATURES Housing in die cast aluminium, formed of two caps joint in the rear part. ApplicationsStreet lighting MaterialFrontally positioned, stainless steel, blocking clench. window blocking frame and dissipator backup in ABS. Blocking bar in aluminium. Asymmetrical street lighting lens (IESNA type II, full cut-off) LensSystem of lens with high precision collimators employed for ScrewsStainless Steel the concentration of the luminous beam ScreenPMMA Neutral white: Power LEDNORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LED Strength against impactsIK 08 EN 13032 REMOTE CONTROL(ww) Power LED Colour of the luminary Top block Grey Ral 7035(Measurement and presentation ofphotometric data for lamps An assigned micro device andBottom block Grey Ral 7036and luminaries) a firmware employed for the Pendency of the fixture 0 - 90Painting processSandblasting, cataphoresis EN 60529 transmission of data;(Specification for degrees of contained in the fixture;protection provided by enclosures) formed of radio receiver or Dimensions (l x h x p)587 x 204 x 288 mm powerline communication:Neutral white: 4.000K - 5.300K EN 50102 - Remote control and adjustment of the total Colour temperature Optional: AccessoriesCw (Cool white) 5.300K - 10.000K weight6.6 kg (Degrees of protection providedby enclosures for electrical luminous flux emitted by theww (warm white) 2.600K - 3.700K 1 fixture per box. equipment against external fixture from 0 to 100% either Case in shaped polyester. mechanical impacts) Packaging manually via specializedDimensions of the box (l x h x p): 600 x 230 x 300 mm Chromatic Rendering weight = 7.0 kgEN 60598 circuits or following 70 < Ra < 80 (Ra= 2A) Index (CRI) (Luminaries and accessories) adjustable timetables;42 boxes on euro pallet. - Instantaneous calculation PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mmEN 62031 of the amount of energy weight = 300 Kg(LED modules for general lighting. consumed; Safety specifications) - Measurement of theLaser Safety Category 1M functionning temperature atEN 61347 the welding point of the LEDs(Lamp control gear. General and safety requirements) and the related alarms; - Evaluation of the Mounting On pole diam. 60 mmTechnical DrawingELECTRICAL FEATURES functionning state (active or On bracket diam. 60 mm EN 61000 (Harmonic current emissions) damaged) and the deriving 90 - 260 V a.c. / 50 - 60Hz alarms; Power supply (mod. Av24 available powered 12V c.c. e 24V c.c.)EN 55015 - Measurement of workingEfficiency(Limits and methods of hours; > 90 Lm/w BallastsElectronic, integrated in the fixture, with >85% efficiencymeasurement of radio disturbance of the luminous source characteristics of electrical Protection againstlighting and similar equipment) tension/current/with auto recovery (IEC 62384 compliant) temperature variations EN 61547 s.on < 1 s - s.off < 1 s Switch on/ off (Equipment for general lighting (instantaneous ignition/ deactivation)Isolation categoryIIpurposes - EMC immunityrequirements) Protection degree Lens space: IP66 (optical interval - power Emissions Ballasts space: IP66 Absentsupply interval) of IR and UV radiations AV24L / AV40L: 350mA LED modules powered with AV24M / AV40M: 500mA constant current (If) AV24H: 700mA Toxic, inorganic elements AbsentAV24L: 28w AV24M: 41wAV24H: 59w Nominal power AV40L: 46w AV40M: 68wPower Factor (PF) PF = 0,97 (PFC active)20 Life span 50.000 h (decrease of the luminous flow: 30%) 11. Industrial Lighting CURVE Street Gallery Lighting TECH Bright soul 12. Industrial Lighting CURVE 30 Lens 40 Lens 80 Lens APPLICATIONS cd/klm C0 - C180 C90 - C270 cd/klmC0 - C180 C90 - C270cd/klm C0 - C180C90 - C270Lighting of wide indoor and outdoor areas. Sports sector, street galleries and industrial 115 Lens Elliptical Lens lighting. Accessories PAINTING CYCLE Sandblasting,KM-CV15-P cataphoresis and painting with polyester powders.cd/klm cd/klmKM-CV45-PC0 - C180 C90 - C270 C0 - C180 C90 - C270 COLOURSRAL 9005Technical Drawing Optional: 158 / 308 / 458 / 608 / 908 mm 70 mm (For orders >50 pc.)OPTIONAL FLOw MODELPOwER FLOwFLOw (Neutral white)RAL 9003 (Cool white)(warm white) CV15L 23w2280Lm2280Lm 1750Lm404 mm CV15M 34w3090Lm3090Lm 2370LmCV30L 35w3420Lm3420Lm 2620LmCV30M 51w4630Lm4630Lm 3550LmCV45L 69w6840Lm6840Lm 5250LmCV45M102w9250Lm9250Lm 7100LmCV60L104w10260Lm 10260Lm7870LmCV60M153w13880Lm 13880Lm 10650Lm24 CV90L139w13680Lm 13680Lm 10490LmCV90M204w18500Lm 18500Lm 14200Lm 13. Industrial Lighting CURVEGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURESLighting of wide indoor and outdoor areas. Single body, extruded aluminium, wide finned surface.Material ApplicationsLighting of sports and industrial structures.Securing frame and lateral taps in aluminium. Street lighting.ScrewsStainless SteelSystem of lens with high precision collimators ScreenPMMA Lensemployed for the concentration of the luminous beam 30 - 40 - 80 - 115 - 10 x 42Strength against impactsIK 08 Neutral white: Power LED RAL 9005NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LEDColour of the fixture Optional: (For orders >50 pc.)EN 13032 REMOTE CONTROL(ww) Power LEDRAL 9003Sandblasting, cataphoresis and painting with (Measurement and presentation of photometric data for lamps An assigned micro device and Painting processand luminaries)polyester powders a firmware employed for the Pendency of the fixture Longitudinal anchoring -90 +90 CV15L / CV15M: 158 x 404 x 83 mm 1.8Kg EN 60529 transmission of data;CV30L / CV30M: 308 x 404 x 83 mm 3.6Kg (Specification for degrees of contained in the fixture; protection provided by enclosures)Dimensions (l x h x p)CV45L / CV45M: 458 x 404 x 83 mm 5.5Kg formed of radio receiver or Neutral white: 4.000K - 5.300K CV60L / CV60M: 608 x 404 x 83 mm 7.5Kg powerline communication:EN 50102 - Remote control and adjustment of the total Colour temperature Optional: AccessoriesCw (Cool white) 5.300K - 10.000KCV90L / CV90M: 908 x 404 x 83 mm1 fixture per box. Case in shaped polyester.11.5Kg (Degrees of protection provided by enclosures for electrical luminous flux emitted by the ww (warm white) 2.600K - 3.700K Dimensions of the box (l x h x p) and weight: 600 x 230 x 300 mm equipment against external fixture from 0 to 100% eitherCV15L / CV15M: 220 x 480 x 110 mm 2.0Kg mechanical impacts) manually via specialized Packaging CV30L / CV30M: 370 x 480 x 110 mm 4.0Kg Chromatic RenderingCV45L / CV45M: 520 x 480 x 110 mm 6.0KgEN 60598 circuits or following 70 < Ra < 80 (Ra= 2A) Index (CRI)CV60L / CV60M: 670 x 480 x 110 mm 8.0Kg (Luminaries and accessories) adjustable timetables; - Instantaneous calculationCV90L / CV90M: 970 x 480 x 110 mm 12.5KgEN 62031 of the amount of energy42 boxes on euro pallet. (LED modules for general lighting. consumed;PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mmSafety specifications) - Measurement of theLaser Safety Category 1M functionning temperature at EN 61347 the welding point of the LEDs (Lamp control gear.ELECTRICAL FEATURES General and safety requirements) and the related alarms; - Evaluation of the MountingOn wall or on pole with bracketTechnical Drawing functionning state (active or EN 61000Power supply90 - 260 V a.c. / 50 - 60Hz(Harmonic current emissions) damaged) and the deriving alarms;Electronic, integrated in the fixture, with >85% efficiencyBallasts EN 55015 - Measurement of working Optional, external ballasts Efficiency (Limits and methods of hours; > 90 Lm/wProtection against measurement of radio disturbance of the luminous sourcetension/current/with auto recovery (IEC 62384 compliant)characteristics of electricaltemperature variationslighting and similar equipment)s.on < 1 s - s.off < 1 s Isolation categoryII EN 61547 Switch on/ off(Equipment for general lighting (instantaneous ignition/ deactivation)Protection degree purposes - EMC immunityLens space: IP66(optical interval - powerrequirements)Ballasts space: IP66supply interval) EmissionsLED modules powered withCV15L / CV30L / CV45L / CV60L / CV90L: 350mA Absent of IR and UV radiationsconstant current (If) CV15M / CV30M / CV45M / CV60M / CV90M: 500mACV15L: 23w CV15M: 34wCV30L: 35w CV30M: 51wNominal power CV45L: 69w CV45M: 102w Toxic, inorganic elements Absent CV60L: 104wCV60M: 153wCV90L: 139wCV90M: 204w Power Factor (PF) PF = 0,97 (PFC active)26Life span 50.000 h (decrease of the luminous flow: 30%) 14. Street Gallery Lighting TECH 80 Lens APPLICATIONS Street and highway gallery lighting.cd/klm C0 - C180C90 - C270 Accessories115 Lens PAINTING CYCLE Sandblasting,KM-CV45-P cataphoresis and painting with polyester powders. KM-TH-CNCOLOURSRAL 9005Technical Drawingcd/klm Optional: 158 / 308 / 458 mm 70 mmC0 - C180C90 - C270(For orders >50 pc.) RAL 9003FLOw MODEL POwER(Neutral white)404 mm TL60L69w6840LmTL60M 102w9250LmTL60H 147w 12040LmTL90L 104w 10260LmTL90M 153w 13880LmTL90H 221w 18060LmTL120L139w 13680Lm28 TL120M204w 18500LmTL120H* 294w 24090Lm* Box with external power 15. Street Gallery Lighting TECHGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURESSingle body, extruded aluminium, wide finned surface.Material ApplicationsStreet and highway gallery lighting. Securing frame and lateral taps in aluminium. ScrewsStainless SteelSymmetrical lens (IESNA type II, full cut-off) ScreenTempered glass 4mm LensSystem of lenses with high precision collimators employed for the concentration of the luminous beamStrength against impactsIK 08 Neutral white: Power LED RAL 9005NORMATIVE FRAME OPTIONALTypology of LED Optional:(Cw) Power LEDColour of the fixture Optional: (For orders >50 pc.)EN 13032 REMOTE CONTROL (ww) Power LEDRAL 9003 (Measurement and presentation of photometric data for lampsSandblasting, cataphoresis and painting withand luminaries) An assigned micro device and Painting processpolyester powders a firmware employed for the Pendency of the fixture Longitudinal anchoring -90 +90EN 60529 transmission of data;TL60L / TL60M: 458 x 404 x 83 mm 6.0Kg (Specification for degrees of contained in the fixture;Dimensions (l x h x p)TL60H / TL90L / TL90M:608 x 404 x 83 mm 7.5Kgprotection provided by enclosures) formed of radio receiver orTL90H / TL120L / TL120M / TL120H: 908 x 404 x 83 mm 12.5Kg powerline communication:Neutral white: 4.000K - 5.300KEN 50102 - Remote control and adjustment of the total Colour temperature Optional:Accessories Cw (Cool white) 5.300K - 10.000K1 fixture per box. Case in shaped polyester.Dimensions of the box (l x h x p) and weight: 600 x 230 x 300 mm (Degrees of protection provided by enclosures for electrical luminous flux emitted by the ww (warm white) 2.600K - 3.700K Packaging TL60L / TL60M: 520 x 480 x 110 mm 6.0Kgequipment against external fixture from 0 to 100% eitherTL60H / TL90L / TL90M:670 x 480 x 110 mm 8.0Kgmechanical impacts) manually via specialized TL90H / TL120L / TL120M / TL120H: 970 x 480 x 110mm 12.5Kg Chromatic Rendering EN 60598 circuits or following 70 < Ra < 80 (Ra= 2A) Index (CRI)PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm(Luminaries and accessories) adjustable timetables; - Instantaneous calculationEN 62031 of the amount of energy (LED modules for general lighting. consumed;Safety specifications) - Measurement of theLaser Safety Category 1M functionning temperature at EN 61347 the welding point of the LEDs (Lamp control gear.General and safety requirements) and the related alarms; - Evaluation of the MountingOn metallic railTechnical Drawing ELECTRICAL FEATURES functionning state (active or EN 61000(Harmonic current emissions) damaged) and the derivingPower supply90 - 260 V a.c. / 50 - 60Hz alarms; EN 55015 - Measurement of working Electronic, integrated in the fixture, with >85% efficiency (Limits and methods of Efficiency Ballasts hours; > 90 Lm/wOptional, external ballasts* (*) (standard on TL120H)measurement of radio disturbance of the luminous sourceProtection againstcharacteristics of electricaltension/current/with auto recovery (IEC 62384 compliant)lighting and similar equipment)temperature variations s.on < 1 s - s.off < 1 sEN 61547 Switch on/ off Isolation categoryII (Equipment for general lighting (instantaneous ignition/ deactivation)purposes - EMC immunityProtection degreerequirements)Lens space: IP66(optical interval - powerBallasts space: IP66 Emissionssupply interval) Absent of IR and UV radiationsTL60L / TL90L / TL120L: 350mALED modules powered withTL60M / TL90M / TL120M: 500mAconstant current (If)TL60H / TL90H / TL120H: 700mATL60L: 69wTL90L: 104wTL120L: 139w Toxic, inorganic elements Absent Nominal power TL60M: 102w TL90M: 153wTL120M: 204wTL60H: 147w TL90H: 221wTL120H: 294w Power Factor (PF) PF = 0,97 (PFC active)30Life span 50.000 h (decrease of the luminous flow: 30%) 16. Street Gallery Lighting TECH Asymmetric Lens APPLICATIONS Street and highway gallery lighting. Street lighting.cd/klm C0 - C180 C90 - C270 Accessories PAINTING CYCLE Sandblasting,KM-CV45-P cataphoresis and painting with polyester powders. KM-TH-CNCOLOURSRAL 9005Technical Drawing FLOw MODELPOwER Optional: (Neutral white) 158 / 308 / 458 mm 70 mm (For orders >50 pc.) TS16L 19w1830Lm RAL 9003 TS16M 27w2470LmTS16H 39w3210Lm404 mm TS24L 28w2740LmTS24M 41w3700LmTS24H 59w4820LmTS32L 37w3650LmTS32M 54w4940LmTS32H 78w6420LmTS40L 46w4560Lm32 TS40M 68w6170LmTS40H 98w8030Lm 17. Street Gallery Lighting TECHGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURESSingle body, extruded aluminium, wide finned surface.Material ApplicationsStreet, street galleries and highway galleries lighting. Securing frame and lateral taps in aluminium. ScrewsStainless SteelAsymmetric street lens (IESNA type II, full cut-off) ScreenTempered glass 4mm LensSystem of lens with high precision collimators employed for the concentration of the luminous beamStrength against impactsIK 08 Neutral white: Power LED RAL 9005 NORMATIVE FRAME OPTIONALTypology of LED Optional:(Cw) Power LEDColor of the fixtureOptional: (For orders >50 pc.) EN 13032 REMOTE CONTROL (ww) Power LEDRAL 9003(Measurement and presentation ofphotometric data for lampsSandblasting, cataphoresis and painting with and luminaries) An assigned micro device and Painting processpolyester powders a firmware employed for the Pendency of the fixture Longitudinal anchoring -90 +90 EN 60529 transmission of data;16L / 16M / 16H / 24L: 158 x 404 x 83 mm2.0Kg (Specification for degrees of contained in the fixture;Dimensions (l x h x p)24M / 24H / 32L / 32M: 308 x 404 x 83 mm4.0Kg protection provided by enclosures) formed of radio receiver or32H / 40L / 40M / 40H: 458 x 404 x 83 mm6.0Kg powerline communication:Neutral white: 4.000K - 5.300K EN 50102 - Remote control and adjustment of the total Colour temperature Optional: Accessories Cw (Cool white) 5.300K - 10.000K1 fixture per box. Case in shaped polyester.Dimensions of the box (l x h x p) and weight:(Degrees of protection providedby enclosures for electrical luminous flux emitted by the ww (warm white) 2.600K - 3.700K Packaging 16L / 16M / 16H / 24L:190 x 110 x 480 mm 2.5Kgequipment against external fixture from 0 to 100% either32H / 40L / 40M / 40H:520 x 110 x 480 mm 6.5Kg mechanical impacts) manually via specialized 24M / 24H / 32L / 32M: 370 x 110 x 480 mm 4.5Kg Chromatic RenderingEN 60598 circuits or following 70 < Ra < 80 (Ra= 2A) Index (CRI)PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm (Luminaries and accessories) adjustable timetables; - Instantaneous calculation EN 62031 of the amount of energy(LED modules for general lighting. consumed; Safety specifications) - Measurement of theLaser Safety Category 1M functionning temperature atEN 61347 the welding point of the LEDs(Lamp control gear. General and safety requirements) and the related alarms; - Evaluation of the MountingOn metallic railTechnical Drawing ELECTRICAL FEATURES functionning state (active orEN 61000Power supply90 - 260 V a.c. / 50 - 60Hz(Harmonic current emissions) damaged) and the deriving alarms;EN 55015Electronic, integrated in the fixture, with >85% efficiency - Measurement of workingEfficiency Ballasts (Limits and methods of > 90 Lm/wOptional, external ballasts hours;of the luminous source measurement of radio disturbanceProtection against characteristics of electricaltension/current/with auto recovery (IEC 62384 compliant) lighting and similar equipment)temperature variations s.on < 1 s - s.off < 1 s EN 61547 Switch on/ off Isolation categoryII(Equipment for general lighting (instantaneous ignition/ deactivation) purposes - EMC immunityProtection degree requirements)Lens space: IP66(optical interval - powerBallasts space: IP66supply interval) Emissions Absent TS16L / TS24L / TS32L / TS40L: 350mA of IR and UV radiationsLED modules powered withTS16M / TS24M / TS32M / TS40M: 500mAconstant current (If)TS16H / TS24H / TS32H / TS40H: 700mATS16L: 19w TS24L: 28w TS32L: 37w TS40L: 46w Toxic, inorganic elements Absent Nominal power TS16M: 27w TS24M: 41w TS32M: 54w TS40M: 68wTS16H: 39w TS24H: 59w TS32H: 78w TS40H: 98w Life span PF = 0,97 (PFC active)34Vita utile stimata (L70)50.000 h (decrease of the luminous flow: 30%) 18. Industrial Lighting DARK AccessoriesTechnical Drawing Deep respect 19. Industrial Lighting DARK 30 Lens 40 Lens 80 Lens APPLICATIONS cd/klm C0 - C180 C90 - C270 cd/klmC0 - C180 C90 - C270cd/klm C0 - C180C90 - C270Industrial Lighting. PAINTING CYCLE 115 Lens Elliptical Lens Sandblasting, cataphoresis and painting with Accessories polyester powders. COLOURScd/klm cd/klm C0 - C180 C90 - C270 C0 - C180 C90 - C270 Aluminium RAL9006 Technical Drawing 270 mm 558 mm OPTIONAL FLOw MODELPOwER FLOwFLOw (Neutral white) (Cool white)(warm white)PI4098w8030Lm8030Lm 6160Lm38 485 mm PI64 147w12050Lm 12050Lm9240Lm 20. Industrial Lighting DARKOPTIONAL GENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES EMERGENCY LIGHTINGMaterial Single body, die cast aluminium, wide finned surface - coolingApplicationsIndustrial Lightingfuction and silicone window frame. Integrated in the fixture, formed of buffer battery and ScrewsStainless Steel emergency unit incorporated. Efficiency in emergencySystem of lens with high precision collimators conditions: ScreenTransparent tempered glassLensemployed for the concentration of the luminous beam 14 Leds - 20WOptional: 30 - 40 - 80 - 115 - 10 x 42 1284Lm (CW) Strength against impactsIK 07 1284Lm (NW) 967Lm (WW)Neutral white: Power LED Color of the fixtureAluminium RAL 9006 NORMATIVE FRAMETypology of LEDEN 13032Optional:(Cw) Power LED (Measurement and presentation of (ww) Power LEDSandblasting, cataphoresis and painting with photometric data for lamps Painting process polyester powders and luminaries) OPTIONAL Neutral white: 4.000K - 5.300K Dimensions (l x h x p)485 x 485 x 558 mm EN 60529 REMOTE CONTROL Colour temperatureOptional: Cw (Cool white) 5.300K - 10.000K ww (warm white) 2.600K - 3.700K(Specification for degrees ofprotection provided by enclosures) An assigned micro device andweight10.0 Kg a firmware employed for theEN 50102 transmission of data; containedChromatic RenderingIndex (CRI)70 < Ra < 80 (Ra= 2A)Accessories1 fixture per box. Case in shaped polyester. (Degrees of protection providedby enclosures for electrical in the fixture; formed of Packaging Dimensions of the box (l x h x p): 525 x 525 x 620 mm radio receiver or powerline Peso = 10.5 kg equipment against external communication:mechanical impacts) - Remote control andPalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mmLaser Safety Category 1MEN 60598 adjustment of the total (Luminaries and accessories) luminous flux emitted by the fixture from 0 to 100% either EN 62031 manually via specialized (LED modules for general lighting. circuits or following Safety specifications)MountingSuspension adjustable timetables; - Instantaneous calculationEN 61347 of the amount of energy(Lamp control gear. General and safety requirements) consumed; - Measurement of the Efficiency > 90 Lm/w Technical Drawingof the luminous sourceEN 61000 functionning temperature at the ELECTRICAL FEATURES (Harmonic current emissions) welding point of the LEDs and the related alarms;EN 55015 - Evaluation of the functionningPower supply90 - 260 V a.c. / 50 - 60Hzs.on < 1 s - s.off < 1 s (Limits and methods of state (active or damaged) andSwitch on/ offmeasurement of radio disturbance(instantaneous ignition/ deactivation) the deriving alarms;BallastsElectronic, integrated in the fixture, with >85% efficiency characteristics of electrical - Measurement of workinglighting and similar equipment) hours;Protection againstEmissionstension/current/with auto recovery (IEC 62384 compliant) EN 61547Absent temperature variations (Equipment for general lightingof IR and UV radiations purposes - EMC immunity Isolation categoryII requirements)Protection degree Lens space: IP66Toxic, inorganic elements Absent (optical interval - power Ballasts space: IP66 supply interval) LED modules powered with 700mA constant current (If) PI40: 98w Nominal power PI64: 147wPower Factor (PF) PF = 0,97 (PFC active)40 Life span 50.000 h (decrease of the luminous flow: 30%) 21. Accessories Technical Drawing Space exists if lit 22. 30 Lens 40 Lens 80 Lens APPLICATIONScd/klmC0 - C180 C90 - C270cd/klm C0 - C180C90 - C270cd/klmC0 - C180C90 - C270Industrial Lighting. PAINTING CYCLE115 Lens Elliptical Lens Sandblasting, cataphoresis and painting with Accessories polyester powders. COLOURS RAL 9005cd/klm cd/klmC0 - C180 C90 - C270 C0 - C180 C90 - C270 RAL 9003Technical Drawing461 mm 147 mm484 mm532 mmOPTIONALFLOwMODELPOwER FLOwFLOw(Neutral white)(Cool white)(warm white) PA20L 23w2280Lm2280Lm 1750Lm PA20H 49w4020Lm4020Lm 3080Lm PA4098w8030Lm8030Lm 6160Lm4470 7014 mmPA8092w9120Lm9120Lm 7000Lm 170 mm170 mm 23. GENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES Single body, die cast aluminium, wide finned surface - coolingMaterial ApplicationsArchitectural Lighting fuction and silicone window frame. ScrewsStainless Steel System of lens with high precision collimators Lensemployed for the concentration of the luminous beamScreenTransparent tempered glass Optional: 30 - 40 - 80 - 115 - 10 x 42Neutral white: Power LED Strength against impactsIK 07 NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LEDEN 13032 REMOTE CONTROL(ww) Power LED Color of the fixtureAluminium RAL 9005Aluminium RAL 9003 (Measurement and presentation of photometric data for lamps An assigned micro device and and luminaries) Neutral white: 4.000K - 5.300K a firmware employed for theSandblasting, cataphoresis and painting with Colour temperature Painting process EN 60529 transmission of data; Optional: Cw (Cool white) 5.300K - 10.000K polyester powders (Specification for degrees of contained in the fixture; ww (warm white) 2.600K - 3.700K protection provided by enclosures) formed of radio receiver orDimensions (l x h x p)PA20L / PA20H: 265 x 370 x 130 mm4.5Kgand weightPA40 / PA80: 532 x 484 x 147 mm 10.5Kg powerline communication:EN 50102 - Remote control and adjustment of the total Chromatic Rendering Index (CRI) 70 < Ra < 80 (Ra= 2A)Accessories1 fixture per box. Case in shaped polyester. (Degrees of protection provided by enclosures for electrical luminous flux emitted by the Dimensions of the box (l x h x p) and weight:equipment against externalPackaging fixture from 0 to 100% eitherPA20L / PA20H: 295 x 375 x 155 mm5,2Kgmechanical impacts) manually via specialized PA40 / PA80: 525 x 440 x 165 mm 11,5Kg circuits or following Laser Safety Category 1MEN 60598(Luminaries and accessories) adjustable timetables; PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm - Instantaneous calculationEN 62031 of the amount of energy (LED modules for general lighting. consumed;Safety specifications) - Measurement of theMountingSuspension functionning temperature at EN 61347 the welding point of the LEDsELECTRICAL FEATURES(Lamp control gear.General and safety requirements) and the related alarms; - Evaluation of the Efficiency > 90 Lm/wTechnical Drawing Power supply90 - 260 V a.c. / 50 - 60Hz functionning state (active or of the luminous sourceEN 61000(Harmonic current emissions) damaged) and the deriving alarms;BallastsElectronic, integrated in the fixture, with >85% efficiencyEN 55015 - Measurement of workings.on < 1 s - s.off < 1 s (Limits and methods of hours;Switch on/ off Protection against measurement of radio disturbance (instantaneous ignition/ deactivation)tension/current/with auto recovery (IEC 62384 compliant)characteristics of electricaltemperature variationslighting and similar equipment)EmissionsIsolation categoryII EN 61547 Absent(Equipment for general lighting of IR and UV radiationspurposes - EMC immunityProtection degreerequirements)Lens space: IP66(optical interval - powerBallasts space: IP66supply interval) Toxic, inorganic elements Absent LED modules powered withPA20L / PA80: 350mAconstant current (If) PA20H / PA40: 700mA PA20L: 23w PA20H: 49wNominal powerPA40: 98wPA80: 92w Power Factor (PF) PF = 0,97 (PFC active) 46Life span 50.000 h (decrease of the luminous flow: 30%) 24. Urban Lighting CITY AccessoriesTechnical Drawing Emotions from the past 25. Urban Lighting CITY Polar Diagram APPLICATIONS Urban Lighting. Lighting of the residential areas.cd/klm C0 - C180 C90 - C270 PAINTING CYCLE Painting with polyester powders.AccessoriesCOLOURSRAL 7024Optional: for 50 pc. (Any colour)440 mmTechnical DrawingOPTIONALFLOw MODELPOwERFLOwFLOw(Neutral white)(Cool white)(warm white)LN18L21w 2050Lm2050Lm1570Lm LN18M31w 2780Lm2780Lm2130Lm 730 mmLN18H44w 3610Lm3610Lm2770Lm 440 mmLN24L28w 2740Lm2740Lm2100Lm LN24M41w 3700Lm3700Lm2840Lm50 LN24H59w 4820Lm4820Lm3700Lm 26. Urban Lighting CITYGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES Single body in die cast aluminiumMaterial ApplicationsUrban Lighting.Pole anchorage ScrewsStainless Steel Symmetric, street lighting lens (type II, full cut-off) LensSystem of lens with high precision collimators ScreenTransparent PMMA employed for the concentration of the luminous beamNeutral white: Power LED Strength against impactsIK 07 NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LEDEN 13032 REMOTE CONTROL(ww) Power LED Color of the fixtureRAL 7024Optional: (For orders >50 pc.) on request (Measurement and presentation of photometric data for lamps An assigned micro device and and luminaries) Neutral white: 4.000K - 5.300K a firmware employed for thePainting processPainting with polyester powders Colour temperatureEN 60529 transmission of data; Optional: Cw (Cool white) 5.300K - 10.000K(Specification for degrees of contained in the fixture; ww (warm white) 2.600K - 3.700K protection provided by enclosures) formed of radio receiver orDimensions (l x h x p)LN18L / LN18M / LN18H: 440 x 440 x 730 mm10 Kgand weightLN24L / LN24M / LN24H: 440 x 440 x 730 mm10 Kg powerline communication:EN 50102 - Remote control and adjustment of the total Chromatic Rendering Index (CRI) 70 < Ra < 80 (Ra= 2A) Accessories Packaging 1 fixture per box. (Degrees of protection provided by enclosures for electrical luminous flux emitted by theequipment against external fixture from 0 to 100% eithermechanical impacts) manually via specialized PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm circuits or following Laser Safety Category 1MEN 60598(Luminaries and accessories) adjustable timetables; - Instantaneous calculationEN 62031 of the amount of energy (LED modules for general lighting. consumed; On poleSafety specifications) - Measurement of theMounting Optional: pole outreach (accessorized) functionning temperature atELECTRICAL FEATURESEN 61347 the welding point of the LEDs (Lamp control gear.General and safety requirements) and the related alarms; - Evaluation of the Efficiency > 90 Lm/wTechnical Drawing Power supply90 - 260 V a.c. / 50 - 60Hz functionning state (active or of the luminous sourceEN 61000(Harmonic current emissions) damaged) and the deriving alarms;BallastsElectronic, integrated in the fixture, with >85% efficiency EN 55015 - Measurement of workings.on < 1 s - s.off < 1 s (Limits and methods of hours;Switch on/ off Protection against (instantaneous ignition/ deactivation)measurement of radio disturbancetension/current/with auto recovery (IEC 62384 compliant)characteristics of electricaltemperature variationslighting and similar equipment)Isolation categoryII EN 61547 Emissions Absent(Equipment for general lighting of IR and UV radiationsProtection degree purposes - EMC immunityLens space: IP65(optical interval - powerrequirements)Ballasts space: IP43supply interval)LN18L / LN24L: 350mA Toxic, inorganic elements Absent LED modules powered withLN18M / LN24M: 500mAconstant current (If)LN18H / LN24H: 700mALN18L: 21w LN24L: 28wNominal power LN18M: 31w LN24M: 41wLN18H: 44w LN24H: 59w Power Factor (PF) PF = 0,97 (PFC active) 52Life span 50.000 h (decrease of the luminous flow: 30%) 27. Urban Lighting GARDEN Expanding harmony 28. Urban Lighting GARDEN Polar Diagram APPLICATIONS Urban Lighting. Lighting of the residential areas.cd/klm C0 - C180 C90 - C270 PAINTING CYCLE Painting with polyester powders.AccessoriesCOLORSRAL 7024Optional: for 50 pc. (Any colour)286 mmTechnical DrawingOPTIONALFLOw MODELPOwERFLOw FLOw(Neutral white)(Cool white) (warm white) LP16L 19w 1830Lm1830Lm1400Lm 600 mm LP16M 27w 2470Lm2470Lm1890LmLP16H 39w 3210Lm3210Lm2460LmLP24L 28w 2740Lm2470Lm2100Lm 286 mm LP24M 41w 3700Lm3700Lm2840Lm56 68 mmLP24H 59w 4820Lm4820Lm3700Lm 29. Urban Lighting GARDENGENERAL FEATURESPHYSICAL AND MECHANICAL FEATURESSingle body in die cast aluminium Material ApplicationsUrban Lighting. Pole anchoringScrewsStainless Steel Symmetric, street lighting lens (type II, full cut-off) LensSystem of lens with high precision collimatorsScreenTransparent PMMA employed for the concentration of the luminous beamNeutral white: Power LEDStrength against impactsIK 07 NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LED EN 13032 REMOTE CONTROL(ww) Power LEDColor of the fixture RAL 7024 Optional: (For orders >50 pc.) on request(Measurement and presentation ofphotometric data for lamps An assigned micro device andand luminaries) Neutral white: 4.000K - 5.300K a firmware employed for the Painting processPainting with polyester powders Colour temperature EN 60529 transmission of data; Optional: Cw (Cool white) 5.300K - 10.000K (Specification for degrees of contained in the fixture; ww (warm white) 2.600K - 3.700Kprotection provided by enclosures) formed of radio receiver or Dimensions (l x h x p)LN18L / LN18M / LN18H: 440 x 440 x 730 mm10 Kg and weightLN24L / LN24M / LN24H: 440 x 440 x 730 mm10 Kg powerline communication: EN 50102 - Remote control andChromatic Rendering(Degrees of protection provided 70 < Ra < 80 (Ra= 2A) adjustment of the total Index (CRI) Packaging 1 fixture per box. by enclosures for electrical luminous flux emitted by the equipment against external fixture from 0 to 100% either mechanical impacts) manually via specializedPalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm circuits or following Laser Safety Category 1M EN 60598 (Luminaries and accessories) adjustable timetables; - Instantaneous calculation EN 62031 of the amount of energy(LED modules for general lighting. consumed; On pole Safety specifications) - Measurement of theMounting Optional: pole outreach (accessorized) functionning temperature at ELECTRICAL FEATURESEN 61347 the welding point of the LEDs(Lamp control gear. and the related alarms; General and safety requirements) - Evaluation of the EfficiencyPower supply90 - 260 V a.c. / 50 - 60Hz > 90 Lm/wEN 61000 functionning state (active or of the luminous source (Harmonic current emissions) damaged) and the deriving alarms; BallastsElectronic, integrated in the fixture, with >85% efficiencyEN 55015 - Measurement of workings.on < 1 s - s.off < 1 s(Limits and methods of hours;Switch on/ offProtection against (instantaneous ignition/ deactivation) measurement of radio disturbance tension/current/with auto recovery (IEC 62384 compliant) characteristics of electrical temperature variations lighting and similar equipment) Isolation categoryII EN 61547 Emissions Absent (Equipment for general lighting of IR and UV radiations Protection degree purposes - EMC immunity Lens space: IP65 (optical interval - powerrequirements) Ballasts space: IP43 supply interval) LN18L / LN24L: 350mA Toxic, inorganic elements AbsentLED modules powered with LN18M / LN24M: 500mA constant current (If) LN18H / LN24H: 700mA LN18L: 21w LN24L: 28w Nominal power LN18M: 31w LN24M: 41w LN18H: 44w LN24H: 59wPower Factor (PF) PF = 0,97 (PFC active) 58 Life span 50.000 h (decrease of the luminous flow: 30%) 30. Urban Lighting GLOBO Reinterpreting the rules 31. Urban Lighting GLOBOPolar Diagram APPLICAZIONI Urban Lighting. Residential Lighting. cd/klmC0 - C180 C90 - C270 PAINTING CYCLE with liquid/ spray, using polyurethanic resins. Accessories COLOURS FixtureRAL 9005 Technical Drawing OPTIONAL FLOwMODELPOwERFLOw FLOw (Neutral white) (Cool white) (warm white) G12L-4014w 1370Lm1370Lm1050LmG12M-4020w 1850Lm1850Lm1420Lm325 mm490 mm G18L-4021w 2050Lm2050Lm1570Lm390 mm G18M-4031w 2780Lm2780Lm2130LmG18L-5021w 2050Lm2050Lm1570Lm62400 mm500 mm 217 mm G18M-5031w 2780Lm2780Lm2130Lm 32. Urban Lighting GLOBOGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES Single body in nylonMaterial ApplicationsUrban and residential lighting Pole anchoring ScrewsStainless Steel Symmetric, street lighting lens (type II, full cut-off) LensSystem of lens with high precision collimators ScreenTransparent, resistent, auto extinguishable Polycarbonate employed for the concentration of the luminous beamNeutral white: Power LED Strength against impactsIK 07NORMATIVE FRAME OPTIONALTypology of LED Optional: (Cw) Power LED EN 13032 REMOTE CONTROL(ww) Power LED Color of the fixtureFixture RAL 9005Transparent screen - block RAL 9005(Measurement and presentation ofphotometric data for lamps An assigned micro device andand luminaries) Neutral white: 4.000K - 5.300K a firmware employed for thePainting processPainting with polyurethane resins Colour temperature EN 60529 transmission of data; Optional: Cw (Cool white) 5.300K - 10.000K (Specification for degrees of contained in the fixture; ww (warm white) 2.600K - 3.700KG12L - 40 / G12M - 40:400 x 390 mm5.0 Kgprotection provided by enclosures) formed of radio receiver orDimensions (l x h x p)G18L - 40 / G18M - 40:400 x 390 mm5.0 Kg powerline communication: and weightEN 50102G18L - 50 / G18M - 50:500 x 490 mm6.0 Kg - Remote control and adjustment of the total Chromatic Rendering Index (CRI) 70 < Ra < 80 (Ra= 2A) Accessories (Degrees of protection providedby enclosures for electricalPackaging 1 fixture per box. luminous flux emitted by the equipment against external fixture from 0 to 100% either mechanical impacts) manually via specialized PalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm circuits or following Laser Safety Category 1M EN 60598 (Luminaries and accessories) adjustable timetables; - Instantaneous calculation EN 62031 of the amount of energy(LED modules for general lighting. consumed; Safety specifications) - Measurement of theMountingOn pole functionning temperature atEN 61347 the welding point of the LEDsELECTRICAL FEATURES (Lamp control gear. General and safety requirements) and the related alarms; - Evaluation of the Efficiency > 90 Lm/wTechnical Drawing Power supply90 - 260 V a.c. / 50 - 60Hz functionning state (active or of the luminous source EN 61000 (Harmonic current emissions) damaged) and the deriving alarms;BallastsElectronic, integrated in the fixture, with >85% efficiency EN 55015 - Measurement of workings.on < 1 s - s.off < 1 s(Limits and methods of hours;Switch on/ off Protection againstmeasurement of radio disturbance (instantaneous ignition/ deactivation)tension/current/with auto recovery (IEC 62384 compliant) characteristics of electricaltemperature variations lighting and similar equipment)EmissionsIsolation categoryIIEN 61547 Absent (Equipment for general lighting of IR and UV radiations purposes - EMC immunityProtection degree requirements)Lens space: IP66(optical interval - powerBallasts space: IP66supply interval) Toxic, inorganic elements Absent LED modules powered withG12L - 40 / G18 L- 40 / G18L - 50: 350mAconstant current (If) G12M - 40 / G18M - 40 / G18M - 50: 500mA G12L - 40: 14w G18L - 40: 21w G18L - 50: 21wNominal powerG12M - 40: 20w G18M - 40: 31w G18M - 50: 31w Power Factor (PF) PF = 0,97 (PFC active) 64Life span 50.000 h (decrease of the luminous flow: 30%) 33. Indoor Lighting CRETAAccessories Technical Drawing Linear simplicity 34. Indoor Lighting CRETA 80 Lens APPLICATIONS Indoor Lighting. PAINTING CYCLE cd/klm C0 - C180 C90 - C270Anodic oxidationAccessories115 Lens COLOURS Satin aluminium KM-CR-CSF Optional: for 50 pc. (Any colour)Technical Drawing 1556 mmcd/klm290 mm C0 - C180 C90 - C27057 mm 1556 mm1256 mm656 mmOPTIONALFLOw MODELPOwERFLOw FLOw(Neutral white)290 mm 290 mm(Cool white) (warm white) CR6037w 3650Lm3650Lm2800Lm 57 mm57 mm CR120 56w 5480Lm5480Lm4200Lm681256 mm 656 mm CR150 74w 7300Lm7300Lm5600Lm 35. Indoor Lighting CRETAOPTIONALGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES REMOTE CONTROL MaterialSingle body in assembled extruded aluminum Integrated in the fixture,ApplicationsIndoor LightingAluminum anchoring system constituted of a device used for: control and adjustment of ScrewsStainless Steel the total luminous flow gave out by the luminary from 0 to System of lens with high precision collimators Lens Satin PMMA 100%, either manually employed for the concentration of the luminous beamScreenOptional: for 50pz - transparent PMMA through specific commercial dimmers with analogue output or electronically through Neutral white: Power LED Strength against impactsIK 07NORMATIVE FRAME specific devices interfaced Typology of LED EN 13032 with the fixture. Optional: (Cw) Power LED (Measurement and presentation ofSatin aluminium (ww) Power LED Color of the fixturephotometric data for lampsOptional: (For orders >50 pc.) - any color and luminaries) Neutral white: 4.000K - 5.300K Colour temperature Painting processAnodic oxidationEN 60529 OPTIONALOptional: Cw (Cool white) 5.300K - 10.000K ww (warm white) 2.600K - 3.700KCR60: 656 x 290 x 57 mm 6.5Kg(Specification for degrees ofprotection provided by enclosures) COURTESY LIGHTINGDimensions (l x h x p)and weightCR120: 1256 x 290 x 57 mm 8.0KgEN 50102CR150: 1556 x 290 x 57 mm 10.5Kg Integrated in the fixture constituted of LED SMD modules. Chromatic Rendering Index (CRI) 70 < Ra < 80 (Ra= 2A)Accessories1 fixture per box. Case in shaped polyester.(Degrees of protection providedby enclosures for electrical Available color of light Dimensions of the box (l x h x p) and weight: equipment against external CW - WW - R - G - B - RGB. Packaging CR60: 700 x 350 x 150 mm 6.5Kg mechanical impacts) Optional remote control forCR120: 1300 x 350 x 150 mm 8.0Kg monitoring the onswitch/ offswitchLaser Safety Category 1M CR150: 1600 x 350 x 150 mm 10.5Kg EN 60598 and for the adjustment and choice (Luminaries and accessories) of color functions (availablePalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm in RGB versions only).EN 62031 False ceiling(LED modules for general lighting. Safety specifications) MountingOptional: Suspension (accessorized) Ceiling (accessorized) EN 61347ELECTRICAL FEATURES (Lamp control gear. OPTIONALEfficiency Technical Drawing Power supply90 - 260 V a.c. / 50 - 60Hz General and safety requirements)INDIRECT LIGHTING of the luminous source > 90 Lm/wEN 61000 (Harmonic current emissions) (only for the suspension version)BallastsElectronic, integrated in the fixture, with >85% efficiency Integrated in the fixture constitutedEN 55015 of LED SMD modules. s.on < 1 s - s.off < 1 s(Limits and methods of Switch on/ off Protection againstmeasurement of radio disturbance Available color of light(instantaneous ignition/ deactivation) tension/current/with auto recovery (IEC 62384 compliant) CW - WW - R - G - B - RGB.characteristics of electricaltemperature variations lighting and similar equipment)EmissionsIsolation categoryIIEN 61547 Absent (Equipment for general lighting of IR and UV radiationsProtection degreepurposes - EMC immunityLens space: IP44requirements)(optical interval - powerBallasts space: IP44supply interval) Toxic, inorganic elements Absent LED modules powered with350mAconstant current (If)CR60: 37wNominal power CR120: 56wCR150: 74wOPTIONALPower Factor (PF) PF = 0,97 (PFC active) EMERGENCY LIGHTING 70 Life span 50.000 h (decrease of the luminous flow: 30%)Integrated in the fixture,formed of buffer battery and of emergency unit. 36. Indoor Lighting MALTA Flawless elegance 37. Indoor Lighting MALTA80 Lens APPLICATIONS Indoor Lighting. PAINTING CYCLEcd/klmC0 - C180 C90 - C270Anodic oxidation Accessories115 Lens COLOURS Satin aluminiumOptional: for 50 pc.KM-ML60-CSFKM-ML30-CSF (Any colour)Technical Drawing cd/klmC0 - C180 C90 - C270 596 mm 290 mm 596 mm290 mm OPTIONAL FLOwMODELPOwERFLOw FLOw (Neutral white) 57 mm (Cool white) (warm white)57 mmML3019w 1830Lm1830Lm1400Lm ML60L 37w 3650Lm3650Lm2800Lm74290 mm 596 mmML60H 78w 6420Lm6420Lm4930Lm 38. Indoor Lighting MALTAOPTIONALGENERAL FEATURES PHYSICAL AND MECHANICAL FEATURES REMOTE CONTROL MaterialSingle body in assembled extruded aluminium Integrated in the fixture,ApplicationsIndoor LightingAluminum anchoring system constituted of a device used for: control and adjustment of ScrewsStainless Steel the total luminous flow gave out by the luminary from 0 to System of lens with high precision collimators Lens Satin PMMA 100%, either manually employed for the concentration of the luminous beamScreenOptional: for 50 pc. - transparent PMMA through specific commercial dimmers with analogue output or electronically through Neutral white: Power LED Strength against impactsIK 05NORMATIVE FRAME specific devices interfaced Typology of LED EN 13032 with the fixture. Optional: (Cw) Power LED (Measurement and presentation ofSatin aluminium (ww) Power LED Color of the fixturephotometric data for lampsOptional: (For orders >50 pc.) - any color and luminaries) Neutral white: 4.000K - 5.300K Colour temperature Painting processAnodic oxidationEN 60529 OPTIONALOptional: Cw (Cool white) 5.300K - 10.000K ww (warm white) 2.600K - 3.700KML30: 290 x 290 x 57 mm 4.0Kg(Specification for degrees ofprotection provided by enclosures) COURTESY LIGHTINGDimensions (l x h x p)and weightML60L: 596 x 596 x 57 mmML60H: 596 x 596 x 57 mm8.0Kg8.5Kg EN 50102 Integrated in the fixture constituted of LED SMD modules. Chromatic Rendering Index (CRI) 70 < Ra < 80 (Ra= 2A)Accessories1 fixture per box. Case in shaped polyester.(Degrees of protection providedby enclosures for electrical Available color of light Dimensions of the box (l x h x p) and weight:equipment against externalPackaging ML30: 350 x 350 x 150 mm 4.5Kg CW - WW - R - G - B - RGB.mechanical impacts) Optional remote control forML60L: 700 x 700 x 150 mm 8.5Kg monitoring the onswitch/ offswitch ML60H: 700 x 700 x 150 mm 8.5Kg Laser Safety Category 1M EN 60598 and for the adjustment and choice (Luminaries and accessories) of color functions (availablePalletDimensions of the pallet (l x h x p): 1200 x 1800 x 800 mm in RGB versions only).EN 62031 False ceiling(LED modules for general lighting. Safety specifications) MountingOptional: Suspension (accessorized)Ceiling (accessorized)EN 61347ELECTRICAL FEATURES (Lamp control gear. OPTIONALEfficiency Technical DrawingGeneral and safety requirements)INDIRECT LIGHTING of the luminous source > 90 Lm/wPower supply90 - 260 V a.c. / 50 - 60HzEN 61000 (Harmonic current emissions) (only for the suspension version)BallastsElectronic, integrated in the fixture, with >85% efficiency Integrated in the fixture constitutedEN 55015 of LED SMD modules. s.on < 1 s - s.off < 1 s(Limits and methods of Switch on/ off Protection againstmeasurement of radio disturbance Available color of light(instantaneous ignition/ deactivation)tension/current/with auto recovery (IEC 62384 compliant) characteristics of electrical CW - WW - R - G - B - RGB.temperature variations lighting and similar equipment)EmissionsIsolation categoryIIEN 61547 Absent (Equipment for general lighting of IR and UV radiationsProtection degreepurposes - EMC immunityLens space: IP44requirements)(optical interval - powerBallasts space: IP44supply interval) Toxic, inorganic elements Absent LED modules powered withMl30 / ML60L: 350mAconstant current (If) ML60H:700mAML30: 19wNominal power ML60L: 37wML60H: 78wOPTIONALPower Factor (PF) PF = 0,97 (PFC active) EMERGENCY LIGHTING 76 Life span 50.000 h (decrease of the luminous flow: 30%)Integrated in the fixture,formed of buffer battery and of emergency unit. 39. Indoor Lighting SATURN Cristal clear circularity 40. Indoor Lighting SATURN 30 Lens 80 Lens115 Lens APPLICATIONS cd/klm C0 - C180 C90 - C270 cd/klmC0 - C180C90 - C270 cd/klmC0 - C180C90 - C270Indoor Lighting.ADVANTAGES The Saturn spotlight is technologically in the forefront. Functionally based on the innovative Nuventix SynJet Accessories System, the spotlight embodies revolutionary heat management functions thanks to a highly reliable and adaptable device without a fan. The cooling sollutions Nuventix SynJet guarantee the high effieciency of our products and allow the spotlight to obtain elevated input in contained spaces without Technical Drawing affecting the LEDs lifespan.123, 41 FERRULE COLOUR m m Optional. 139,5 mmOPTIONAL FLOw MODELPOwERFLOwFLOw (Neutral white) 56,5 mm(Cool white)(warm white)FR - PAR30 - 10H 21w2010Lm 2010Lm 1540Lm80 139,5 mmFR - PAR30 - 16H 35w3210Lm 3210Lm 2460Lm 41. Indoor Lighting SATURN GENERAL FEATURESPHYSICAL AND MECHANICAL FEATURES MaterialHousing - the innovative Nuventix SynJet System;ApplicationsIndoor Lighting PMMA ferruleSystem of lens with high precision collimatorsScrewsStainless Steelemployed for the concentration of the luminous beamLensFR - PAR30 - 10H: 30 - 80 - 115FR - PAR30 - 16H: 80 - 115 Neutral white: Power LEDScreenPMMA NORMATIVE FRAMETypology of LEDEN 13032Optional: (Cw) Power LED(Measurement and presentation of(ww) Power LEDphotometric data for lampsColor Any color and luminaries)Neutral white: 4.000K - 5.300KColour temperatureEN 60529Optional: Cw (Cool white) 5.300K - 10.000K(Specification for degrees ofDimensions (l x h x p)ww (warm white) 2.600K - 3.700K FR - PAR30: 139.5 x 56.5 mm360grprotection provided by enclosures)and weightEN 50102Chromatic Rendering (Degrees of protection provided70 < Ra < 80 (Ra= 2A)Index (CRI) by enclosures for electricalequipment against external mechanical impacts) Laser Safety Category 1MEN 60598 (Luminaries and accessories)ELECTRICAL FEATURESEN 62031(LED modules for general lighting. Safety specifications)MountingOn false ceiling; bore diameter - 125mm Power supply90 - 260 V a.c. / 50 - 60HzEN 61347(Lamp control gear. General and safety requirements)EfficiencyBallastsElectronic, integrated in the fixture, with >85% efficiency > 90 Lm/w EN 61000of the luminous source (Harmonic current emissions)Protection againsttension/current/with auto recovery (IEC 62384 compliant)EN 55015s.on < 1 s - s.off < 1 stemperature variations (Limits and methods ofSwitch on/ offmeasurement of radio disturbance(instantaneous ignition/ deactivation) characteristics of electrical lighting and similar equipment)Isolation categoryIIEmissions EN 61547Absent(Equipment for general lightingof IR and UV radiationsProtection degreepurposes - EMC immunity(optical interval - power IP23requirements)supply interval) Toxic, inorganic elements AbsentLED modules powered withFAR - PAR30 - 10H: 21wconstant current (If) FAR - PAR30 - 16H: 35w Power Factor (PF) PF = 0,97 (PFC active) 82 Life span 50.000 h (decrease of the luminous flow: 30%) 42. Indoor Lighting MOON Unobtrusive charm 43. Indoor Lighting MOONCone Diagram APPLICATIONS Indoor Lighting. ADVANTAGES The Moon spotlight is technologically in the forefront. Functionally based on the innovative Nuventix SynJet Accessories System, the spotlight embodies revolutionary heat management functions thanks to a highly reliable and adaptable device without a fan. The cooling sollutions Nuventix SynJet guarantee the high effieciency of our products and allow the DistanceCone diameterIllumination IlluminationHalving angle spotlight to obtain elevated input in contained spaces without Technical Drawing affecting the LEDs lifespan. 68,8 mm 57,4 mm FERRULE COLOUR Optional. 92 mmFLOwCOLORMODEL POwER CRI(Neutral white)TEMPERATURE92 mm FR - MR16 - 140014w1400 Lm 70 5000KFR - MR16 - 105514w1055 Lm 85 4000K61,06 mm FR - MR16 - 960 14w 960 Lm 85 3000K 21 mm FR - MR16 - 805 14w 805 Lm 95 3500K86 70,80 mm92 mm FR - MR16 - 710 14w 710 Lm 95 2700K 44. Indoor Lighting MOON GENERAL FEATURESPHYSICAL AND MECHANICAL FEATURES MaterialHousing - the innovative Nuventix SynJet System;ApplicationsIndoor Lighting PMMA ferrule System of lens with high precision collimatorsScrewsStainless SteelLensemployed for the concentration of the luminous beam of 120ScreenPMMA NORMATIVE FRAMETypology of LED white Power LEDEN 13032(Measurement and presentation ofphotometric data for lampsColor Any colorFR - MR16 - 1400: 5000K and luminaries)FR - MR16 - 1055: 4000KEN 60529Colour temperatureFR - MR16 - 960: 3000KDimensions (l x h x p)(Specification for degrees ofFR - MR16 - 805: 3500K FR - MR16: 92 x 92 x 61 mm220gr protection provided by enclosures)and weightFR - MR16 - 710: 2700KFR - MR16 - 1400: 70EN 50102FR - MR16 - 1055: 85(Degrees of protection providedChromatic Rendering by enclosures for electricalFR - MR16 - 960: 85Index (CRI) equipment against externalFR - MR16 - 805: 95 mechanical impacts)FR - MR16 - 710: 95EN 60598ELECTRICAL FEATURES(Luminaries and accessories)Laser Safety Category 1M EN 62031Power supply90 - 260 V a.c. / 50 - 60Hz (LED modules for general lighting. Safety specifications) MountingOn false ceiling; bore diameter - 72mmEN 61347(Lamp control gear.BallastsElectronic, integrated in the fixture, with >85% efficiency General and safety requirements)FR - MR16 - 1400: 108Lm/wFR - MR16 - 1055: 81Lm/wEN 61000EfficiencyProtection against (Harmonic current emissions)FR - MR16 - 960: 74Lm/w tension/current/with auto recovery (IEC 62384 compliant)of the luminous sourceFR - MR16 - 805: 62Lm/w temperature variationsEN 55015FR - MR16 - 710: 55Lm/w (Limits and methods ofmeasurement of radio disturbances.on < 1 s - s.off < 1 sIsolation categoryII characteristics of electricalSwitch on/ off lighting and similar equipment)(instantaneous ignition/ deactivation) Protection degree EN 61547(optical interval - power IP23(Equipment for general lightingEmissions supply interval) purposes - EMC immunityAbsentrequirements)of IR and UV radiationsFR - MR16 - 1400: 14wFR - MR16 - 1055: 14wLED modules powered withFR - MR16 - 960: 14wconstant current (If)FR - MR16 - 805: 14wToxic, inorganic elements AbsentFR - MR16 - 710: 14wPower Factor (PF) PF = 0,97 (PFC active) 88 Life span 50.000 h (decrease of the luminous flow: 30%) 45. Indoor Lighting TUBE AccessoriesTechnical Drawing Just evolution 46. Indoor Lighting TUBEPolar Diagram 1051059090 7575 60 10060 1504545APPLICATIONS200 Indoor Lighting.250Industrial Lighting. 3015 0 15 30cd/klmC0 - C180 C90 - C270PAINTING CYCLE Anodic oxidation COLOURS Satin aluminiumOptional: for 50 pc. (Any colour) Technical Drawing 28 mmOPTIONALFLOwMODELPOwERFLOw(Neutral white)(Neutral white) TB18AC - 12 9,6w912Lm604LmTB36AC - 2016w1520Lm1008Lm 92590 mm / 1200 mm / 1500 mm TB58AC - 2823w2128Lm1450Lm 47. Indoor Lighting TUBE GENERAL FEATURESPHYSICAL AND MECHANICAL FEATURES Single body in extruded aluminium.Indoor Lighting.MaterialApplicationsFinned surface - cooling function.Industrial Lighting. ScrewsStainless Steel System of lens with high precision collimatorsLensScreenSatin PMMAemployed for the concentration of the luminous beam of 120Cw: AC Power LEDColor of the luminary Satin aluminium NORMATIVE FRAMETypology of LED EN 13032Optional: (Nw) AC Power LED(Measurement and presentation ofPainting cycleAnodic oxidation photometric data for lampsand luminaries)Cw (Cool white): 5.000K - 6.000KTB18AC: 28 x 590 mm 200grColour temperatureDimensions (l x h x p) EN 60529TB36AC: 28 x 1200 mm400grand weight (Specification for degrees ofOptional: Nw (Neutral white) 3.000K - 4.000KTB58AC: 28 x 1500 mm600gr protection provided by enclosures)EN 50102Chromatic RenderingIndex (CRI)70 < Ra < 80 (Ra= 2A) Accessories25 fixture per box. Case in shaped polyester.Dimensions of the box ( x l) and weight: (Degrees of protection provided by enclosures for electricalPackaging TB18AC: 30 x 650 mm 300grequipment against externalTB36AC: 30 x 1250 mm600gr mechanical impacts)TB58AC: 26 x 1550 mm800grLaser Safety Category 1M EN 60598(Luminaries and accessories)PalletDimensions of pallet (l x h x p): 1200 x 800 x 1800 mmEN 62031 (LED modules for general lighting.Safety specifications)MountingDirect, G13 connexion EN 61347 (Lamp control gear.General and safety requirements)Efficiency > 90 Lm/w (Cw) Technical DrawingELECTRICAL FEATURESof the luminous source > 63 Lm/w (Nw) EN 61000(Harmonic current emissions)Power supply90 - 260 V a.c. / 50 - 60Hz EN 55015s.on < 1 s - s.off < 1 s(Limits and methods ofSwitch on/ offProtection against measurement of radio disturbance(instantaneous ignition/ deactivation)tension/current/with auto recovery (IEC 62384 compliant)characteristics of electricaltemperature variationslighting and similar equipment) Emissions Isolation categoryII EN 61547Absent (Equipment for general lightingof IR and UV radiationspurposes - EMC immunityProtection degreerequirements)(optical interval - power IP23supply interval)Toxic, inorganic elements AbsentTB18AC: 9,6wLED modules powered withTB36AC: 16wconstant current (If)TB58AC: 23w Power Factor (PF) PF = 0,95 94Cw 40.000 hLife span Nw 30.000 h(decrease of the luminous flow: 30%) 48. Street Security Lighting DELCAR Attentive symmetry 49. Street Security Lighting DELCAR TECHNICAL FEATURES BrandDLDSeries DELCARModels Mono and bifacialN LED From 2 to 12 LEDAPPLICATIONS Colour white, blue, yellow, amber, green, red Track delimiter.DescriptionTrack delimiterCOLOURSApplications Lighting fixture for light grazing sidewalksRAL 9005 Effective powerFrom 0,5 to 2wAccessoriesBallasts Input 20 - 36 Vdc RAL 7035 Housing in autoextinguishing material; translucent PMMAMaterials treated agains yellowing (Nor. Ref. UL94VO)FittingAnchors in nylon and screws in stainless steel A4Degree of protection IP68 Technical DrawingCertifications CEwork temperature -25 / 55CLifespan 60.000 h.Input cable2x1,5 mmq L= 1m94,34 mmDimensions ( l x p x h ) 95 x 100 x 20 mmweight 250gr 100 mm 9820 mm 50. Accessories and Optionals 51. Accessories PRODUCT FEATURESPRODUCTFEATURESKM-CR-CSF Galvanized sheet. KM-CV45-PSteel.Bracket for Creta Set of 2 pieces to be employedAdjustable mount Employed for the installation of mCR150/ CR120/ CR6 should the items CR150/ CR120/ CV45L/ CV45M/CV60L5m29CR60 not be installed on ceiling CV60M/ CV90L/ CV90M on wall/ floor. The accessory is composed of two pieces.PRODUCT FEATURES 60 mmKM-ML30-CSF Galvanized sheet.151,5 mmBracket for Malta Set of 2 pieces to be employed mML30should the item ML30274 mm5m29not be installed on ceilingPRODUCT FEATURESKM-ML60-CSF Galvanized sheet.595mBracket for Malta Set of 2 pieces to be employedmML60L/ ML60Hshould the items ML60L/ ML60Hnot be installed on ceilingPRODUCTFEATURESKM-CV15-PSteel.Adjustable mount Employed for the installation of CV15L/ CV15M/CV30L/ CV30M on wall/ floor. The accessory is composed of two pieces. 250 mm PRODUCT FEATURESKM-W-TP To use for the installation of the 60 mmHead pole bracket wave luminary on pole 60.90 fixed mount. 17 8m260 mm m 8,5mm80 mm40 mmPRODUCT FEATURES 8,5mm114 mm 59 mmKM-W-OR To use for the installation of theArticulated bracket wave luminary on pole 60.Adjustable mount.PRODUCTFEATURES 220 mm 84 mmKM-TH-CN Steel.System of fixing on rail 61 mm To install the devices 102 mm 406 TLxxx / TSxxx on duct. 255 mm 120 mm 52. Optional Emergency Lighting Kit SERIES CURVENEFFECTIVENOMINAL FLOw EMERGENCY LIGHTING UNITMODEL KIT CODE LEDSPOwERAUTONOMYINSTALLED IN THE ExTERNALCw Nw wwELECTRICAL CASECV15LCV15MCV30LCV60MCV45LKE - CV10 12w 1h 1140Lm 1140Lm880LmCV45MCV60LCV60MCV90LDESCRIPTIONCV90MThe kit is devised to avoid the discomfort caused by sudden lack of illumination. In case of blackout the connection of the fixture with the emergency lighting circuit allows the partial ignition of the LED modules. The system has a 60 minutes autonomy. Upon return of the power supply the battery recharges automatically in 24 h (should it have got discharged). A green LED , frontally positioned on the electric case which contains the kit, signals if the kit is functioning and if it is charging. The LED turns off when the kit is functioning in emergency mode.SERIES DARKNEFFECTIVENOMINAL FLOwMODEL KIT CODEAUTONOMY LEDSPOwERCw Nw ww GENERAL FEATURES - Emergency only functioning or constant light functioning with electronic transformers. - Available in constant current version for Power LED (12x1w) or in voltage version for LED modules (12V/24V).PI40 - Instantaneous ignition in case of blackout.KE - DK14 16w 1h 1600Lm 1600Lm 1220LmPI64 - High temperature Ni-Cd battery - LED charging indicator. - Protection against prolonged discharge. - Possibility to repress the system either in Idle Mode through centralized external remote control or in Repress Mode. - Possibility of self diagnosis through an integrated microprocessor. - Abiding by: EN1347-2-13; EN1347-2-7; EN1547; EN55015; EN60598-2-22; EN61000-3-2;SELV; SERIES CRETA / MALTA NEFFECTIVENOMINAL FLOwMODEL KIT CODEAUTONOMY LEDSPOwERCw Nw wwCR60CR120 KE - CRTECHNICAL DATA - Supply voltage: 220/240V-50/60HzCR150 - Supply current: 20mA - Max. exercise temperature measured on the coating: 70 16 20w 1h 1830Lm 1830Lm 1400Lm- External temperature: 050C - Recharge: 24h - Max. distance between the ballast and the lamp:2mML60L- Clamp sustainer: 1.5mmKE - ML 104ML60H- Length of the battery cable: 280mm - Length of the LED cable: 350mm - Bore for the mounting of the LED: 8.8mm - weight: 430g 53. Optional CRETA / MALTACOURTESY COLOR OF THE LIGHT AND VALUESOF THE LUMINOUS FLOwCOLOR OF THE LIGHT AND VALUESOF THE LUMINOUS FLOwINDIRECT LIGHTING KIT MODELKIT CODE N EFFECTIVELEDS POwER Cool warmMODELKIT CODE N EFFECTIVELEDS POwERCoolwarmLIGHTING KIT RedGreenBlueRGB Red GreenBlue RGB whitewhite white white Performances: low consumption andIndirect lighting kit available only high luminous intensity; for suspended ceiling lamps Type of LED: SMD 5060CR60KC - CR60 - X* 46 7w235Lm 210Lm50Lm 140Lm45Lm 270Lm CR60KI - CR60 - X*46 7w 235Lm 210Lm 50Lm 140Lm 45Lm 270Lm Beam aperture: 90 Beam aperture: 120working current: 350mA Supply voltage: 12V d.c. work current: 100mACR120 KC - CR120 - X*76 16w 575Lm 515Lm 115Lm 340Lm 105Lm 660Lm CR120 KI - CR120 - X* 76 16w575Lm 515Lm 115Lm 340Lm 105Lm 660LmCR150 KC - CR150 - X*10423w 780Lm 695Lm 155Lm 455Lm 145Lm 890Lm CR150 KI - CR150 - X* 10423w780Lm 695Lm 155Lm 455Lm 145Lm 890LmML30KC - ML30 - X* 16 2w 65Lm 60Lm 15Lm 40Lm 15Lm 80LmML30KI - ML30 - X*16 2w 65Lm60Lm15Lm 40Lm15Lm 80LmML60KC - ML60 - X* 80 12w 400Lm 360Lm80Lm 235Lm75Lm 460Lm ML60KI - ML60 - X*80 12w400Lm 360Lm 80Lm 235Lm 75Lm 460Lm *X = colour of the light; in order to compose the code: KC - ML30 - R (example of code for the courtesy kit Malta ML 30, red) MOUNTING KIT OPTIONSMODELKIT CODE SUSPENSION FALSE CEILING CEILING MOUNTINGMOUNTINGMOUNTING CR60KM - CR - X* SPS PFNCSFCR120 KM - CR - X* SPS PFNCSFCR150 KM - CR - X* SPS PFNCSFML30KM - ML30 - X* SPS PFNCSFML60KM - ML60 - X* SPS PFNCSF 106*X = type of mounting in order to compose the code: KC - ML30 - PFN (example of code for the mounting kit Malta ML30 on ceiling) 54. Normative references Use of TechnoloGy solId sTaTe lIGhTInG examples of lighting design 1. Introduction2. Normative references3. Terms and definitions4. ME/MEW - Series of lighting classes5. CE - Series of lighting classes6. S/A - Series of lighting classes 55. 1 Introduction 4 ME/MEW - Series of lighting classes A lighting class is defined by a set of photometric requirements aiming at the visual needs of certain road users inThe ME and MEw classes in Tables 1a and 1b are intended for drivers of motorized vehicles on traffic routes of certain types of road areas and environment.medium to high driving speeds. The purpose of introducing lighting classes is to make it easier to develop and use road lighting products and services in CEN member countries. Table 1a - ME Series of lighting classes The lighting classes have been defined with consideration of road lighting standards in these countries aiming at harmonization of requirements where possible. Luminance of the road surface of theLighting of Disability glare However, some lighting classes and subclasses reflect particular situations and national approaches based oncarriageway for thew dry road surface conditionsurroundings traditional, climatic and other conditions. ClassL in cd/m2 Uo UI TI in %aSR2b[minimum][minimum][minimum][maximum][minimum]maintained] 2 Normative References ME1 ME22,01,50,40,4 0,7 0,71010 0,5 0,5This European Standard incorporates by dated or updated reference, provisions from other publications.ME3a 1,0 0,40,715 0,5 These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. ME3b 1,0 0,40,615 0,5 EN 13201-3, Road lighting Part 3: Calculation of performance. ME3c 1,0 0,40,515 0,5 EN 13201-4, Road lighting Part 4: Methods of measuring lighting performance. ME4a0,75 0,40,615 0,5 ME4b0,75 0,40,515 0,5 3 Terms and DefinitionsME50,5 0,35 0,415 0,5 For the purposes of this European Standard, the following terms and definitions apply:ME60,3 0,35 0,415no requirement3.1 Average road surface luminance (of a carriageway of a road).aAn increase of 5 percentage points in TI can be permitted where low luminance light sources are used. Unit is candelas per square meter (cd/m) bThis criterion can be applied only where there are no traffic areas with their own requirements adjacent to the carriageway. 3.2 Longitudinal uniformity (of road surface luminance of a driving lane). Ratio of the lowest to the highest road surface luminance found in a line in the center along a driving lane.3.3 Longitudinal uniformity (of road surface luminance of a carriageway). Table 1b - MEW Series of lighting classes Lowest of the longitudinal uniformities of the driving lanes of the carriageway. Luminance of the road surface of the carriageway forDisabilityLighting of 3.4 Threshold increment (TI).thew dry road surface conditionglaresurroundings Measure of the loss of visibility caused by the disability glare of the luminaries of a road lighting installation. ClassL in cd/m2 3.5 Surround ratio (of illumination of a carriageway of a road) (SR).Uo UIa UoTI in %a SR2b[minimum] Average illuminance on strips just outside the edges of the carriageway in proportion to the average [minimum][minimum] [minimum] [maximum] [minimum]maintained] illuminance strips just inside the edges.3.6 Average illuminance (on a road area) (hs). MEw1 2,0 0,4 0,60,1510 0,5 Horizontal illuminance averaged over a road area. Unit is lux (lx). MEw2 1,5 0,4 0,60,1510 0,5 3.7 Minimum illuminance (on a road area) (Emin). Lowest illuminance on a road area. Unit is lux (lx). MEw3 1,0 0,4 0,60,1515 0,5 3.8 Hemispherical illuminance (at a point on a road) (hs). Luminous flow on a small hemisphere with a horizontal base divided by the surface area of the hemisphere. (lx)no MEw40,75 0,40,1515 0,5 requirement 3.9Average hemispherical illuminance (on a road area) ().Hemispherical illuminance averaged over a road area. (lx) no MEw5 0,50,350,1515 0,5 3.10 Overall uniformity (of road surface luminance, illuminance on a road area or hemispherical illuminance) (Uo).requirementRatio of the lowest to the average value.a The application of this criterion is voluntary, but it can be applied on motorways.110 3.11 Maintained level (of average road surface luminance, average or minimum illuminance on roadarea, average hemispherical illuminance, minimum semi-cylindrical illuminance or minimum vertical planeilluminance). bc An increase of 5 percentage points in TI can be permitted where low luminance light sources are used. This criterion can only be applied where there are no traffic areas with their own requirements adjacent to the carriageway. 56. 5 CE - Series of lighting classes The CE classes in Table 2 are intended for drivers of motorized vehicles, and other road users, on conflict areas such as shopping streets, road intersections of some complexity, roundabouts, queuing areas etc.Table 2 - CE Series of lighting classes Table 4 - A Series of lighting classes Horizontal illuminance Horizontal illuminance ClassClass in lx Uo in lxUo[minimum maintained] [minimum] [minimum maintained][minimum]CE0500,4A15 0,15 CE1300,4A23 0,15 CE2200,4A32 0,15 CE3150,4A1,50,15 CE4100,4A51 0,15 CE57,5 0,4A6 performance not determinatedperformance not determinateda The application of this criterion is voluntary, but it can be applied on motorways. b An increase of 5 percentage points in TI can be permitted where low luminance light sources are used. 6 S/A - Series of lighting classes c This criterion can only be applied where there are no traffic areas with their own requirements adjacent to the carriageway.The S classes in Table 3 or the A classes in Table 4 are intended for pedestrians and pedal cyclists on footways, cycleways, emergency lanes and other road areas lying separately or along the carriageway of a traffic route, and for residential roads, pedestrian streets, parking places, schoolyards etc.Table 3 - S Series of lighting classes Horizontal illuminance Class in lx Uo[minimum maintained] [minimum]S1 15 5 S2 10 3 S3 7,5 1,5 S4 51 S5 3 0,6 S6 2 0,6 S7 performance not determinated performance not determinated112 aTo provide for uniformity, the actual value of the maintained average illuminance may not exceed 1,5 times the minimum E value indicated for the class. 57. Examples of lighting planning Street highwayStreet roadDetails Type of street: highwayDetailsType of street: roadLighting category: ME3b(3)Lighting category : ME4b(3)planning planningwidth of carriageway : 10m2 (2 carriageways)width of carriageway :7,5 m (2 carriageways)Pole location: one sidedPole location: one sidedDistance between poles: 35m Distance between poles: 30mInstallation height: 35 m (1) Installation height: 8m(1)Distance from the roadside: Distance from the roadside:Mounting type_ head poleMounting type_ head polePendency of the fixture= 0 Pendency of the fixture= 0 (1) (2) (3) are equivalent(1) (2) (3) are equivalentto the pattern on the right to the pattern on the right(2)(2) Legislative Lm [cd/m2] UO UITI [%]SR EM [LX]Emin / EMLegislativeLm [cd/m2] UOUITI [%]SR EM [LX]Emin / EMrequirements1 0,4 0,6 15 0,5 requirements 0,75 0,4 0,6 15 0,5w74H10,40,65 0,5180,4w74L0,830,40,550,5160,4SAP2501,50,40,8100,6250,5SAP1501,150,40,710 0,5210,4 Polar Diagram A - W74H Polar Diagram A - W74L cd/klm 73% C0 - C180 C90 - C270 Values in Lux, Scale 1: 308Values in Lux, Scale 1: 258 Polar Diagram SAP250 Polar Diagram SAP150105105 105105 9090 90907575 75756060 6060 160 1604545 4545 11430cd/klm C0 - C180 15C90 - C270320015 30 73% Values in Lux, Scale 1: 308 30 cd/klmC0 - C18015 C90 - C2703200153073%Values in Lux, Scale 1: 258 58. Esempi di progettazione illuminotecnicaUrban roadBicycle pathDetailsType of road: urban road DetailsType of street: bicycle path Lighting category : ME5 (3) Lighting category plan : ME4b(3)planningplanning width of carriageway :6 m (1carriageway)width of carriageway :6 m (1carriageway) Pole location: one sidedPole location: one sided Distance between poles: 30m Distance between poles: 30m Installation height: 7 m(1) Installation height: 7m (1) Distance from the roadside: 0.5mDistance from the roadside: 0.5m Mounting type_ head poleMounting type_ head pale Pendency of the fixture=0Pendency of the fixture=0(1) (2) (3) are equivalent(1) (2) (3) are equivalent to the pattern on the right to the pattern on the right(2) (2) LegislativeLm [cd/m2] UO UI TI [%]SREM [LX] Emin / EM Legislative EM [LX] Emin [LX]Emin / EMrequirements 0,5 0,35 0,4 15 0,5requirements 10 3w37M 0,7 0,380,5 100,5 11 0,3 w24L13 50,4SAP100 0,9 0,420,5 110,5 17 0,2 SAP70 21 70,3 Polar Diagram A - W37M Polar Diagram - W24LValues in Lux, Scale 1: 258 Values in Lux, Scale 1: 186 Polar Diagram SAP100 Polar Diagram SAP70 116Values in Lux, Scale 1: 258 Values in Lux, Scale 1: 186 59. RondaboutDetailsType of street= roundabout Lighting category: CE2(3)planning width of carriageway: 7,5 m Pole location: one sided width of roundabout: 40 m Installation height: 11 m (1) Distance from the roadside: 0.5m Mounting type: head pole Pendency of the fixture: 0 (1) (2) (3) are equivalent to the pattern on the right(2) Legislative EM [LX]Emin [LX] Emin / EMrequirements 20 0,4w74H3011 0,4SAP2504715 0,3 Polar Diagram A - W74H Values in Lux, Scale 1: 428 Polar Diagram SAP250 118 Values in Lux, Scale 1: 428 60. www.kasperslighting.com