komatsu - coolon€¦ · komatsu wa1200 komatsu wa1200 litin ein simulation eport 5 this report is...

9
KOMATSU WA1200 Lighting Design Simulation Report This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Upload: others

Post on 19-Oct-2020

9 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

KOMATSUWA1200

Lighting Design Simulation Report

This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application.

Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 2: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

SIMULATIONKOMATSU WA1200OPTION A

KOMATSU WA1200Lighting Design Simulation Report

2This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 3: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

LUMINAIRE SCHEDULE

OPTION A

Model No. Luminaire Optic Type QuantityCP9-L07 CP9 Flood Light L07 - 14° Beam Angle 2

CP9-O209 CP9 Flood Light O209 - 40° x 18° Beam Angle 2

CP9-L25 CP9 Flood Light L25 - 50° Beam Angle 10

KOMATSU WA1200

MODEL CP9OPTIC L07ANGLE 15°

DIRECTION 0°

MODEL CP24OPTIC L25ANGLE 35°

DIRECTION 90°

MODEL CP24OPTIC L25ANGLE 50°

DIRECTION 45°

MODEL CP9OPTIC L25ANGLE 10°

DIRECTION 0°

MODEL CP9OPTIC O209ANGLE 15°

DIRECTION 0°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 210°

MODEL CP9OPTIC L25ANGLE 45°

DIRECTION 45°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 180°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 180°MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 150°

MODEL CP9OPTIC L25ANGLE 10°

DIRECTION 0°

MODEL CP9OPTIC L25ANGLE 45°

DIRECTION 315°

MODEL CP9OPTIC L07ANGLE 35°

DIRECTION 270°

KOMATSU WA1200Lighting Design Simulation Report

3This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 4: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

Total LLF: 0.7

ISOLINE VIEW

OPTION AKOMATSU WA1200

-50

-40

-30

-20

-10

20

30

40

50

0m

10

100

100

50

50

50

50

25

25

25

25

10

10

10

10

10

5

5

5

5

5

1

1

1

KOMATSU WA1200Lighting Design Simulation Report

4This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 5: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

OPERATOR’S VIEW

OPTION AKOMATSU WA1200

KOMATSU WA1200Lighting Design Simulation Report

5This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 6: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

SIMULATION

OPTION BKOMATSU WA1200

KOMATSU WA1200Lighting Design Simulation Report

6This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 7: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

LUMINAIRE SCHEDULE

OPTION B

MODEL CP9OPTIC L07ANGLE 15°

DIRECTION 0°

MODEL CP24OPTIC L25ANGLE 35°

DIRECTION 90°

MODEL CP24OPTIC L25ANGLE 50°

DIRECTION 45°

MODEL CP9OPTIC NOPANGLE 25°

DIRECTION 180°

MODEL CP9OPTIC L25ANGLE 10°

DIRECTION 0°

MODEL CP9OPTIC O209ANGLE 15°

DIRECTION 0°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 210°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 195°

MODEL CP9OPTIC L25ANGLE 45°

DIRECTION 45°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 180°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 180°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 165°

MODEL CP9OPTIC L25ANGLE 35°

DIRECTION 150°

KOMATSU WA1200

Model No. Luminaire Optic Type QuantityCP9-NOP CP9 Flood Light No Optics - 120° Beam Angle 1

CP9-L07 CP9 Flood Light L07 - 14° Beam Angle 2

CP9-O209 CP9 Flood Light O209 - 40° x 18° Beam Angle 6

CP9-L25 CP9 Flood Light L25 - 50° Beam Angle 12

MODEL CP9OPTIC O209ANGLE 5°

DIRECTION 0°

MODEL CP9OPTIC L25ANGLE 10°

DIRECTION 0°

MODEL CP9OPTIC L25ANGLE 45°

DIRECTION 315°

MODEL CP9OPTIC L07ANGLE 35°

DIRECTION 270°

KOMATSU WA1200Lighting Design Simulation Report

7This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 8: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

ISOLINE VIEW

OPTION BKOMATSU WA1200

Total LLF: 0.7

-50

-40

-30

-20

-10

20

30

40

50

0m

10

100100

100

50

50

50

50

25

25

25

25

10

10

10

10

10

5

5

5

5

5

1

KOMATSU WA1200Lighting Design Simulation Report

8This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.

Page 9: KOMATSU - Coolon€¦ · KOMATSU WA1200 KOMATSU WA1200 Litin ein Simulation eport 5 This report is compiled to provide illustrations of product use for a particular application. It

OPERATOR’S VIEW

OPTION BKOMATSU WA1200

KOMATSU WA1200Lighting Design Simulation Report

9This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.