korean r&d on the 6-pulse converter unit for iter ac… presentations/so1... · korean r&d...
TRANSCRIPT
KOREAN R&D ON THE 6KOREAN R&D ON THE 6--PULSE CONVERTER UNIT PULSE CONVERTER UNIT FOR ITER AC/DC CONVERTERSFOR ITER AC/DC CONVERTERS
SOFE 2011
2011. 06. 27
J. S. Oh1), J. Choi1), J. H. Suh1), H. Liu2), S. Lee2), H. Park2), W. Jung2),
S. Jo2), H. Tan3), J. Tao3), P. Fu4)
1) ITER Korea, National Fusion Research Institute, Republic of Korea
2) Dawonsys Corp., Republic of Korea
3) ITER Organization, France
4) Academy of Sciences Institute of Plasma Physics, China
ITERITER
AC/DC ConvertersAC/DC Converters
1
ITER Coil Power Supply System
French Power
Transmission
Grid (400 kV, 500 MW)
66 kV
AC
DC
SwitchingNetwork
Unit
CS SYSTEM
AC
DC
Fast Discharge
Unit
TF SYSTEM
Fast Discharge
Unit
CN/KOCN/KO
22 kV AC
DC
CC SYSTEM
RPC
RPC SYSTEM
3 x 300 MVA
3 x 250 MVA
AC
DC
Fast Discharge
Unit
PF SYSTEM
RFRF
2
Block Diagram of Coil Power Supplies
TF
PF1
CS3U
CS2U
CS1U
CS1L
CS2L
CS3L
PF6
PF5
PF4
PF3
PF2
PF
CS
CS
CS
CS
PF
CS
CS
TC
CCB1
CCB2
CCB3
CC
CC
CC
CCT1
CCT2
CCT3
CC
CC
CC
CCS1
CCS2
CCS3
CCS
CCS
CCS
PF PF
PF PF
PF PF
PF PF
VS
PF
CS
CS
CS
CS
PF
CS
CS
PF
PF
PF
PF
VS VS VS VS VS
CS 1.35 kV/45 kA, 6 ea(+6ea)
PF 1.35 kV/55 kA/, 14 ea(+2ea)
VS 1.35 kV/22.5 kA, 2ea(+4ea)
TC 0.7 kV/68 kA, 1 ea
CC 0.1 kV/10 kA, 6 ea
CCS 0.45 kV/10 kA, 3 ea
Total 32 ea (+12ea: Phase-2)
DL1
DL2
RPC1
RPC2
RPC3
Building 32Building 33
Building 38/39
CN-DA
KO-DA
Phase-2
3
AC/DC Converter Building
4
Main DC Bus
Bars Reactors
Converter
HV
Transformer
Interconnecting Bus BarsHVAC
Installation
Corridors
31 m x 149 m
13m×11m×7m
KOREAN R&D ON ITERKOREAN R&D ON ITER
AC/DC ConvertersAC/DC Converters
5
Korean Package
No. Item Set InputMax On-load
Output VoltageMax Current
1 TF Converter 1 66kV/50Hz ±650V, ±160V 68kA
2 CS Converters 6 66kV/50Hz ±1050V ±45kA
3 VS Converters 2 66kV/50Hz ±1050V ±22.5kA
4 CCU/L Converters 6 22kV/50Hz ±65V ±10kA
5 CCS Converters 3 22kV/50Hz ±325V ±10kA
6 Dummy Load 1 6.73mH, 45kA(30s)/55kA(20s)/68kA(14s)/7.75kA
7 Master Controller 1 Integrated Controller of Coil Power Supply System
9 Spare 1 For Converters, Master Controllers, Transformers
10 Technical Support during Commissioning
6
Project Schedule and R&D PlanProject Schedule and R&D Plan
20082008 20092009 20102010 20112011 20122012 20132013 20142014 20152015 20162016 20172017 20182018 20192019
1st Delivery1st Delivery
(’14.5)(’14.5)Contract Contract
(’11.7)(’11.7)
Group 1Group 1
(CC/VS/DL)(CC/VS/DL)
Group 1Group 1
(CC/VS/DL)(CC/VS/DL)
Last DeliveryLast Delivery
(’16.12)(’16.12)
Key Key
Milestone Milestone
Key Key
Milestone Milestone
ProcurementProcurement
Schedule Schedule
ProcurementProcurement
Schedule Schedule
PAPA
(’11.3)(’11.3)
R&DR&DR&DR&D
BuildingBuilding
Integrated TestIntegrated TestInstallationInstallation
Manufacturing/FATManufacturing/FAT
CDCD
CACA
PDPD FDFD
FD/MD(1)FD/MD(1)
FD/MD(2)FD/MD(2)
FATFAT
SATSAT
FATFAT
FATFAT
FATFAT
CC / VSCC / VS
CSCS
CS / TFCS / TF
CC/VS/DLCC/VS/DLPDPD
SATSATINSTALL.INSTALL.
Group 2Group 2
(CS/TF)(CS/TF)
Group 2Group 2
(CS/TF)(CS/TF)
PA: Procurement Arrangement
CD: Concept Design
CA: Contract Award
PD: Preliminary Design
FD: Final Design
MD: Manufacturing Design
FAT: Factory Acceptance Test
SAT: Site Acceptance Test
PA: Procurement Arrangement
CD: Concept Design
CA: Contract Award
PD: Preliminary Design
FD: Final Design
MD: Manufacturing Design
FAT: Factory Acceptance Test
SAT: Site Acceptance Test
11stst PlasmaPlasma
(’19.11)(’19.11)
Industry WorksIndustry Works
R&DR&D--11 R&DR&D--22
PCRPCR--187187
(’10.9)(’10.9)
SATSAT
(’18.2)(’18.2)
MasterMaster
ControllerController
MasterMaster
ControllerControllerMaster ControllerMaster Controller
7
R&D-1 and R&D-2
R&D-1R&D-2
R&D-1 R&D-2
8
AC/DC ConverterAC/DC Converter
R&DR&D--11
9
R&D-1: Issues
Mechanical Structure
Clamping Design
Current Sharing of Parallel Devices
Fault Suppression Capability (FSC)
10
6 Pulse Converter Rating
Max. Load Voltage: 1.55 kV
DC Current: 11.25 kA
Converter Capacity: 24 MVA
Maximum Fault Current 175 kA (FDR2001)
Number of Thyristors
per arm7+1
Thyristor Type 5 inches
Thyristor Peak
Forward/Reverse Voltage5.2 kV
R&D-1: Design PARAMETERS
11
Mechanical Structure for AC/DC Bus Bar
R&D-1: Mechanical Structure
AC BusAC Bus
DC Bus
AC Bus
DC Bus
DC Bus
DC Bus
DC Bus
AC Bus
DC Bus
DC Bus
AC Bus
12
R&D-1: Clamping Design
Double-side clamping design (left) and pressure distribution (right)
Single-side clamping design (left) and pressure distribution (right)
Thyristor Clamping Pressure
110kN±15% (9~12.18MPa)
115 mm (Diameter)
13
R&D-1: Fabricated Unit
Single Phase Thyristor Rectifier (1:6 Scale)
Size: 2.1(W)x1.5(D)x2.7(H) m
Weight: 2.5 ton
14
3D Design Fabricated Unit
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0 50 100 150 200
Cu
rren
t Im
ba
lan
ce F
act
or
Peak Current (kA)
R&D-1: Current Sharing
A
B
B: Detail Waveform of FSC condition
A: Current Imbalance of 1.5 at rated value
B: Current Imbalance of 1.1 at FSC value
15
R&D-1: FSC Test
16
Thyristor I2t = 50-55 MA2s
Thyristor Surge Current > 100 kA
Measured Data
- Arc Voltage : 2.24 kV
- I2t (melting) = 6.25 MA2s
- I2t (total) = 9.11 MA2s
- Breaking Current = 83.5 kA
- Pre-arc RMS Current = 44.1 kA
- Melting time = 3.2 ms
- Clearing time = 5.1 ms
Ferraz Fuse
1550 V, 2800 A, 17.8 MA2s
AC/DC ConverterAC/DC Converter
R&DR&D--22
17
R&D-2: Issues
Current Sharing Improvement
Structural Design for Full Scale Unit
Rated Current Test for 6-Pulse Converter
Installation and Maintenance
18
R&D-2: Design Parameters
6 Pulse Converter Rating
Max. Load Voltage: 1.35 kV
DC Current: 25 kA
Converter Capacity: 32 MVA
FSC Level 150 kA (DC terminal short)
No. of Thyristors per arm 9+1
Thyristor Type 5 inches
Thyristor Peak
Forward/Reverse Voltage5.2 kV
19
R&D-2: Current Sharing Improvement
20
[9 kA, CH1~8: 200 A/div, CH9~10: 2 kA/div]
9 kA
[21 kA, CH1~8: 500 A/div, CH9~10: 5 kA/div]
21 kA
Transformer for Test
R&D-2: Structural Design for Full Scale Unit
Horizontal Layer (2011)
~2.8x4x3m
Stacked 2 Layers (2010)
~4x3x6m
Integrated 2 layers (2009)
~2.5x1.5x3.9m
For Ease of Fabrication and Maintenance!
21
R&D-2: Structural Cooling Design
AC Bus Bar Cooling Path DC Bus Bar Cooling Path
22
R&D-2: Structural Seismic Analysis
Natural Frequency (Mode 1) = 11.558Hz > 1.3×(6~7Hz)
Mode 1Mode 2
23
R&D-2: Structural EM Force
Max. Stress at Tie Rod = 20 MPa < 111.8 MPa
(σmax=20 MPa, δmax=0.35 mm)
EM Force @ 500 kA
d
LIIF
21
7102
24
R&D-2: Fabricated Converter Module
Full Scale 6-Pulse Converter Unit
25
R&D-2: Rate Current Test Circuit
26
R&D-2: Rated Current Test Configuration
30 kA Current Test Configuration of 6-Pulse Converter Unit
27
R&D-2: Rated Current Test Result
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05-500
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Time [sec.]
Curr
ent
[A]
data1
data2
data3
data4
data5
data6
data7
data8
data9
data10
< R phase Current>
< R Phase Imbalance>
1 2 3 4 5 6 7 8 9 10700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
Channel
Curr
ent
[A]
120%
80%
< S Phase Current>
< S Phase Imbalance>
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05-500
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Time [sec.]
Curr
ent
[A]
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
1 2 3 4 5 6 7 8 9 10700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
Channel
Curr
ent
[A]
120%
80%
< T Phase Current>
< T Phase Imbalance>
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05-500
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Time [sec.]
Curr
ent
[A]
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
1 2 3 4 5 6 7 8 9 10700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
Channel
Curr
ent
[A]
120%
80%
28
R&D-2: Installation Plan
29
R&D-2: Maintenance Plan
30
KOREAN R&D ON KOREAN R&D ON
THE CONVERTER CONTROLLER FOR THE CONVERTER CONTROLLER FOR
ITER AC/DC CONVERTERSITER AC/DC CONVERTERS
WED Poster SP3WED Poster SP3--3838
31
ITER Converter Controller R&D
260μsec80μsec
T2T1
Double DSP interrupt timing
1msec
T3
1 kHz Fast Control Test
Circulation Current Simulation and Test
32