kosha18001 mv/mvn - jaroonratjrr1.jaroonrat.com/assets/pump-mv_mvn_catalog_eng.pdf · discharge...
TRANSCRIPT
MV/MVNMarine Vertical Pump
C 1406 E C
www.hsgoodsprings.com
HEAD OFFICE 254-8, Gongdeok-Dong, Mapo-Gu, Seoul, Korea 121-710 TEL : 82-2-3279-8310CHANGWON PLANT 43-1, Ungnam-Dong, Changwon-Si, Kyungsangnam-Do, Korea 641-290 TEL : 82-55-268-8976
This brochure does not contain all informations and any warranty or guarantee of any kind.Also, all informations herein is subject to change without notice.
High EfficiencyEquipment
ISO 9001 ISO14001 OHSAS 18001
KOSHA18001
Springs of Living Water
General
2 I 3 MV/MVN
Handling Water Sea Water, Fresh WaterNet Positive Suction Head Less than -5mMax. Allowable Suction Pressure 4 kgf /㎠Hydrostatic Test Pressures 20 kgf /㎠Max. Allowable Revolution Up to 1800 rpm(3600rpm)Rotation Clockwise viewed from MotorImpeller Type ClosedLubrication Self-lubrication by handing waterSealing Type Mechanical Seal
FlangesSuction JIS(KS) 16K FFDischarge JIS(KS) 16K FF
Casing BronzeSea Water Impeller Stainless Steel
Material Shaft Stainless SteelCasing Cast Iron
Fresh Water Impeller Stainless Steel Shaft Stainless Steel
MV/MVN
Pump Type
MV Spacer
MVN Close Coupled
0/1/2
Priming Type
0 No Supply1 Air Ejector2 Vacuum Pump
150A
Nozzle Dia. (mm)
Suction
Discharge
Services
Model Designation
Standard Specification
Option Specification- Self Priming Unit- Non Standard Flange : JIS 16K RF, DIN, etc.- Materials are available in various bronze alloys and other different materials suited to individual application
Standard Accessories- Discharge Pressure Gauge 1EA- Suction Pressure Gauge 1EA- Gauge Board 1EA- Gauge Root Valve 2EA- Sealing Pipe 1EA
Bilge, Fire & G/SPump
Emergency Fire Pump
Others
Design and Construction Features
Motor Frame•Compliance with IEC motor•Casting material •Large opening for maintenance•Gauge board & priming system
Shaft Sealing•M/seal or gland packing type•Rubber bellows seal type•O-Ring seal
Fluid Dynamic Design•Hydraulic impeller design on CFD•High efficiency, low NPSH & low noise•Bronze or cast iron
Spacer Coupling•Rigid coupling type•Space for easy dismantle
without removal of motor &pedestal
Pump Shaft •Integral flange for high strength
using friction welding•Composite Line bearing for
lubrication
Liner(Casing) Ring•Standard tolerance for non
galling of metal contacts•Replaceable flat type
construction
Sectional Drawing
4 I 5 MV/MVN
60Hz, 1750, 3500rpm
50Hz, 1450, 2900rpm
Selection Chart
Part No. Name of PartReq. No. For Sea Water For Fresh Waterfor 1pump Material Name JIS Material Name JIS
101 Volute Casing 1 Bronze CAC406 Cast Iron FC250
102 Stuffing Housing 1 Bronze CAC406 Cast Iron FC250
103 Casing Ring 2 Bronze CAC406 Bronze CAC406
104 Anode 1 Zinc - Zinc -
201 Shaft 1 Stainless Steel SUS304 Stainless Steel SUS304
202 Coupling Spacer 1 Ductile Cast Iron FCD450 Ductile Cast Iron FCD450
203 Motor Coupling 1 Ductile Cast Iron FCD450 Ductile Cast Iron FCD450
221 Coupling Bolt 4 Alloy Steel SNB7 Alloy Steel SNB7
222 Coupling Bolt/Nut 4 Alloy Steel SNB7/S45C Alloy Steel SNB7/S45C
301 Impeller 1 Stainless Steel SUS304 Stainless Steel SUS304
302 Impeller Washer 1 Stainless Steel SUS304 Stainless Steel SUS304
303 Impeller Key 1 Stainless Steel SUS304 Stainless Steel SUS304
401 Mechanical Seal 1 - - - -
402 Seal Cover 1 Bronze CAC406 Cast Iron FC200
501 O Ring 1 Rubber NBR Rubber NBR
601 Line Bearing 1 Composite - Composite -
901 Motor Frame 1 Cast Iron FC250 Cast Iron FC200
MV
Marine Vertical Pump
Model A B C D H1 H2 LB N T X Z øAC
MVN80A 300 300 205 230 125 557 710 100 25 300 24 420
MVN100A 300 300 210 240 140 582 920 100 25 300 26 530
MVN150A 510 510 380 470 230 795 1180 120 25 300 28 580
Dimensions : mm
※ Note that dimensions as above are described as for reference also should be subject to change in approval
MVN
Outline Dimensions
6 I 7 MV/MVN
Model A B C D H1 H2 LB N T X Y Z øAC
MV80A 300 300 205 230 125 710 710 100 25 300 800 24 420
MV100A 300 300 210 240 140 735 920 100 25 300 800 26 530
MV150A 510 510 380 470 230 1015 1180 120 25 300 1000 28 580
Dimensions : mm
※ Note that dimensions as above are described as for reference also should be subject to change in approval
MV