ksk 3435 wilshire blvd., suite 2905 los angeles, ca 90010 ... · 3435 wilshire blvd., suite 2905...
TRANSCRIPT
A0.0
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
COVER SHEET
5TH (TYPE III-A)
4TH (TYPE III-A)
3RD (TYPE III-A)
2ND (TYPE III-A)
1ST (TYPE I-A)
BASE (TYPE I-A)
AREA
BUILDING CODE AREA (GROSS)
PROPOSED FAR
4,342 SF
FLOOR LEVEL
26,806 SF
4,277 SF
5,161 SF
4,342 SF
4,342 SF
4,342 SF
5TH
4TH
3RD
2ND
1ST
BASE
ZONING CODE AREA (NET)
PROPOSED FAR
FLOOR LEVEL AREA
301 SF
116 SF
17,181 SF
4,191 SF
4,191 SF
4,191 SF
4,191 SF
2
19
21
BICYCLE PARKING
REQUIRED PROPOSED
2
21
19
15'-0"
8'-0"
YARD SETBACK
REQUIRED PROPOSED
15'-3"
5'-8" PER TOC
(E) FRONT
(N) SIDE
17'-0" 11'-11"(W) REAR
(S) SIDE 8'-0" 5'-8" PER TOC
DENSITY CALCULATION
R4-2 400 SF/DU
ZONE DENSITY
7,321 SF
LOT AREA
19 DU
ALLOWED UNIT
19 DU
PROPOSED UNIT
ALLOWABLE F.A.R (FLOOR AREA PER ZONING CODE IS USED TO COMPUTE)
R4-2 6:1
ZONE F.A.R
4,800 SF
BUILDABLE AREA
28,800 SF
MAX. FAR
17,181
PROPOSED FAR
-
2,125 SF
350 SF
OPEN SPACE CALCULATION
REQUIRED PROPOSED
<3 HABITABLE
=3 HABITABLE
>3 HABITABLE
PRIVATE BALCONY
OPEN SPACE
TOTAL
-
2,549 SF
2,475 SF 2,549 SF
311 SF
LANDSCAPE CALCULATION
REQUIRED PROPOSED25% OF COMMONOPEN SPACE
MIN. 742 SF
7
TREE PLANTATION
REQUIRED PROPOSED
(1) 24" BOX TREE/ 4 D.U
TOTAL
1 TREE/ 500 SFFRONT YARD
1
8 810
-
10
AUTOMOBILE PARKING
REQUIRED PROPOSED
10
25
-
RESIDENTS/LONG-TERM
GUEST/SHORT-TERM
TOTAL
SPACES REDUCED TO 0.5PER TOC
5TH
4TH
3RD
2ND
1ST
BASE
SCHOOL CODE AREA (ACCESSIBLE)
PROPOSED FAR
4,342 SF
AREAFLOOR LEVEL
26,806 SF
4,277 SF
5,161 SF
4,342 SF
4,342 SF
4,342 SF
ARCHITECT
KSK DESIGN
3435 WILSHIRE BLVD. SUITE 2905
LOS ANGELES, CA 90010
TEL: 213 - 388 - 3693
FAX: 213 - 386 - 4052
A0.0 TITLE SHEET
A0.1 NOTES
A0.2 NOTES
A0.3 NOTES
A1.0 SITE PLAN
A2.1 1ST FLOOR PLAN
A2.2 2ND FLOOR PLAN
A2.3 3RD FLOOR PLAN
A2.4 4TH FLOOR PLAN
A2.5 ROOF PLAN
A2.6 ENLARGED FLOOR PLAN
A2.7 ENLARGED FLOOR PLAN
A2.8 ENLARGED FLOOR PLAN
A3.0 ELEVATION
A3.1 ELEVATION
A4.0 SECTION
A4.1 SECTION DETAIL
A5.0 WINDOW, DOOR SCHEDULE
A.60 STAIR ENLARGED PLAN
A6.1 STAIR-1 SECTION, STAIR DETAIL
A6.2 STAIR-2 SECTION
A7.0 DETAILS
A7.1 DETAILS
A7.2 DETAILS
A7.3 DETAILS
A7.4 DETAILS
A8.2 ADA NOTES
A8.3 ADA DETAILS
PROJECT ADDRESS
355 S. KINGSLEY DR.
LOS ANGELES, CA 90020
ZONING INFOMATION:
ARCHITECTURAL
LOT DATA VICINITY MAP
ARCHITECTURAL KEY NOTES
SHEET INDEX
1. 1/4:12 MIN. SLOPED ROOF W/ CLASS "A" COMP. ROOFING. ROLL DOWN OR TORCH INSTALL PER
MANUFACTURES SPECIFICATIONS. ESR-1274 (SEE SPEC SHEET ON A 102)
MODEL:
INITIAL REFLECTIVITY:
INITIAL EMISSIVITY:
3YR REFLECTIVITY:
3YR EMISSIVITY:
AGED SRI INDEX:
2. PROVIDE ELECTRICAL SERVICE AND METERS, LOCATION TO BE COORDINATED & APPROVED BY
SERVICE PROVIDER. NOTE: A NEW OR RELOCATED ELECTRICAL SERVICE SHALL BE PROVIDED W/
A GROUNDING ELECTRODE.
- THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR
INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC
INSTALLATION. THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END
FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY
MARKED AS "FOR FUTURE SOLAR ELECTRIC".
(4.211.4, ENERGY CODE 110.10)
3. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE
DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF
THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING
4. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED ACCESS TO
ANY WATER OR POWER DISTRIBUTION FACILITIES ( POWER POLES, PULL-BOXES,
TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCE ETC.) OR TO THE LOCATION
OF A HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER
LINES-WHETHER OR NOT THIS LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY
CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
5. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE
REQUIRED.
6. A COPY OF THE EVALUATION REPORT AND/PRE CONDITIONS OF LISTING SHALL BE MADE
AVAILABLE AT THE JOB SITE.
7. STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. ONE OR MORE OF THE
FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF ADJACENT
PROPERTY, PREVENT EROSION AND RETAIN SOIL RUNOFF ON THE SITE.
8. THE BUILDING SHALL BE EQUIPPED WITH AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM
IN ACCORDANCE WITH SECTION R313.3 OR NFPA 13D SPRINKLER SYSTEM MUST BE APPROVED BY
PLUMBING DIVISION PRIOR TO INSTALLATION.
9. APPROVED BUILDING ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION SHALL BE PROVIDED AN MAINTAIN SO AS TO BE PLAINLY VISIBLE AND LEGIBLE
FROM THE STREET FRONTING THE PROPERTY. THE NUMBERS SHALL CONTRAST WITH THEIR
BACKGROUND, BE ARABIC NUMERALS OR ALPHABET LETTERS, AND BE A MINIMUM OF 4 INCHES
HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH PER FIRE CODE 505.1 (R319)
10. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS WITH A
MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (R401.3).
11. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH
UL-325. (R309.4)
12. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE
AVAILABLE AT THE JOB SITE.
13. DESIGNATED AREA FOR FUTURE INSTALLATION OF SATELLITE DISHES. SATELLITE DISHES NEED
TO BE LOCATED AWAY FROM STREET AND SCREENED BY ARCHITECTURAL MEANS.
14. PROVIDE EMERGENCY RESPONDER RADIO COVERAGE PER LAFC 510.1
CODE INFO.
CITY OF LOS ANGELES, BUILDING & SAFETY DEPT.
BUILDING CODE: 2017 CALIFORNIA BUILDING CODE
PLUMBING CODE: 2017 CITY OF LOS ANGELES PLUMBING CODE
MECHANICAL CODE: 2017 CITY OF LOS ANGELES MECHANICAL CODE
ELECTRICAL CODE: 2017 CITY OF LOS ANGELES ELECTRICAL CODE
5-STORY 19-UNIT APARTMENT BUILDING
PROJECT TEAM
BUILDING DATA
PROJECT DATA
LANDSCAPE ARCHITECT
DSK LANDSCAPE
3000 W 6TH ST. SUITE 300
LOS ANGELES, CA 90020
TEL: 213 - 382 - 3113
M.E.P
INNOVATIVE DESIGN ENGINEERS
1106 W. MAGNOLIA BLVD.
BURBANK, CA 91506
TEL: 818 - 842 - 7285
STRUCTURAL
BOLD ENGINEER
3055 WILSHIRE BLVD. SUITE 880
LOS ANGELES, CA 90010
TEL: 213 - 386 - 3049
PROJECT DESCRIPTION:
NEW 19-UNIT APARTMENT BUILDING; 4 LEVELS RESIDENTIAL, OVER 1 STORY OF
PARKING ON GRADE, AND 1 STORY OF BASEMENT PARKING.
NFPA-13 FIRE SPRINKLER THROUGH OUT BUILDING.
EMERGENCY RESPONDER COVERAGE REQUIRED PER LAFC 510.
TWO-WAY COMMUNICATION REQUIRED AT ELEVATOR LOBBIES.
STANDBY POWER IS REQUIRED FOR ELEVATOR.
THIS PROJECT IS 100% PRIVATELY FUNDED WITH NO TAX CREDITS AND IS NOT
PUBLIC HOUSING.
DEFERRED PLAN CHECK SUBMITTALS, UNDER SEPARATE APPLICATION:
1. BLOCK FENCE WALLS
2. FIRE SPRINKLER SYSTEM
3. MECHANICAL, ELECTRICAL & PLUMBING ENGINEERING
4. SHORING
5. DEMOLITION
6. STEEL STAIRS
UNDERLYING ZONING:
ZONING INFORMATION:
REQUIRED YARDS:
MAXIMUM HEIGHT:
PROPOSED HEIGHT:
PER ZONING CODE:
LOT AREA:
BUILDABLE AREA:
MAXIMUM F.A.R:
PROPOSED F.A.R:
ALLOWABLE DENSITY:
PROPOSED DENSITY:
R4-2 (ZONE CHANGE)
ENTERPRISE ZONE
FRONT YARD = 15'-0"
SIDE YARDS = 8'-0"
REAR YARD = 18'-0"
U.L
55'-0"
PER ZONING CODE:
7,321 SF (AFTER HWY DEDICATION)
4,800 SF
6:1 = 28,800 SF
3.6:1 = 17,181 SF
7,321 SF / 400 = 18.3 UNITS
19 UNITS
5TH (R-2)
4TH (R-2)
3RD (R-2)
2ND (R-2)
1ST (S-2)
BASE (S-2)
OCCUPANCY
TOTAL
PERSONSFLOOR LEVEL
22
20
1ST (R-2) 2
22
22
22
22
132
OTIS GEN2
4TH ST.
DRIVERAMP DOWN TO BASEMENT
TRANSFORMER
6FT. X 4FT.
GENERATOR
11'-11"
REAR SETBACK 122'-10"
15'-3"
FRONT SETBACK
5'-8
"
SID
E
SE
TB
AC
K
38
'-6
"
5'-8
"
SID
E
SE
TB
AC
K3
8'-6
"
5'-8
"
SID
E
SE
TB
AC
K
122'-10"
PE
DE
ST
RIA
N P
AT
H O
F T
RA
VE
L
PEDESTRIAN PATH OF TRAVEL
SHORT TERM
BICYCLE PARKING
EG
RE
SS
P
AT
H O
F T
RA
VE
L
(N) 6'-0"HI. C.M.U. WALL SPLIT SIDE ON
NEIGHBOR SIDE & STUCCO FIN. ON
PROJECT SIDE
LINE OF BUILDING ABOVE
19-UNIT 5-STORY TOC APARTMENT
4 STORY TYPE III-A, NFPA 13
RESIDENTIAL FLOOR
1 LEVEL TYPE I-A, NFPA 13
PARKING GARAGE
1 LEVEL TYPE 1-A, NFPA 13
BASEMENT PARKING
DRIVEWAY
DRIVEWAY
36'-5" 15'-0" 53'-11" 17'-6"
44
'-2
"
4'-2"
LANDSCAPE
49
'-1
0"
150'-0"
3'-0
"1
0'-0
"
12'-0" 3'-0"
(N) TREE
MIN. 24" BOX. (TYP.)
(N) TREE
MIN. 24" BOX. (TYP.)
LANDSCAPE
PLANTER
LANDSCAPE
(N) TREE
MIN. 24" BOX. (TYP.)
(N
) S
CR
EE
NIN
G
VE
GE
TA
TIO
N
LANDSCAPE
LANDSCAPE
PLANTER
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
WATER PROOFING NOTES:
WATERPROOFING SYSTEMS CORPORATION OR EQUAL.
1. BELOW GRADE BASEMENT WALLS
A. CONCRETE POURED IN PLACE WALLS:
* INSTALL 1 LAYER OF MlRADRI 60 (L.A.R.R. #25094) OR BITUTHENE 3000
(I.C.B.O. #3997 / L.A.R.R. #24386) BY WR. GRACE WATERPROOFING MEMBRANE.
* INSTALL 1 LAYER OF MlRADRAIN 6200 XL OR HYDRODUCT 220 (I.C.B.O.
#3997 / L.A.R.R. #24386) DRAINAGE BOARD.
B. MASONRY WALLS:
*INSTALL 3 COATS OR 90 MILS OF ELASTOMERIC FLUID APPLIED MEMBRANE
SUCH AS PACIFIC POLYMERS' ELASTO-DECK 'BT' TYPE II (LA.R.R #24350)
*INSTALL MlRADRAIN 6200 XL DRAINAGE BOARD.
2. OVER CONCRETE DECK WATERPROOFING
A. BELOW TILE
* INSTALL 3 COATS OR 90 MILS OF FLUID APPLIED ELASTOMERIC
MEMBRANE SUCH AS PACIFIC POLYMERS' ELASTO-DECK 5500 (LA.R.R #24028)
* BROADCAST SAND ONTO FINAL COAT OR INSTALL PROTECTION COURSE
SUCH AS MlRADRI 200V OR ROOFING CAP SHEET.
B. NO TILE:
* INSTALL PACIFIC POLYMERS' ELASTO-DECK "5000X2" (L.A.R.R. #24208) AS
PER MANUFACTURER'S SPECIFICATION.
3. OVER WOOD DECK
A. BELOW TILE
* SAME SCOPE OF WORK AS ITEM #11A.
B. NO TILE
* SAME SCOPE OF WORK AS ITEM #11B.
4. PLANTERS
* INSTALL 3 COATS OR 90 MILS OF PACIFIC POLYMERS' ELASTO-DECK 'BT'
FLUID APPLIED MEMBRANE.
* INSTALL PROTECTION COURSE SUCH AS MlRADRI 200V (L.A.R.R. #24208)
100% UNCOLORED CONCRETE W/ SMOOTH CEMENT FINISH, INITIAL SOLAR
REFLECTANCE >0.30 AS DETERMINED PER ASTME918 OR C1549.
PAVED AREA:
1. PROVIDE AN APPROVED SPARK ARRESTOR FOR THE CHIMNEY OF A
FIREPLACE, STOVE, OR BARBECUE. (LAMC 57.20.25)
2. PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE
A MIN. OF 4 IN. ABOVE THE EARTH OR 2 IN. ABOVE PAVED AREAS. WEEP
SCREEDS SHALL BE OF A TYPE WHICH WILL ALLOW TRAPPED WATER TO
DRAIN TO THE EXTERIOR OF THE BUILDING. (SHOW THESE DIMENSIONS
ON A FOUNDATION DETAIL DRAWING.) (SEC. 2512.1.2)
OTHER NOTES:
SITE PLAN SCALE: 1/8"=1'-0"
LEGEND
: 2ND-7TH FLOOR (RESIDENTIAL AREA)
A1.0
SITE PLAN
STD
STD
STD
STD
SCHINDLER 3300
10
'-4
"
17
'-2
"1
5'-0
"
32
'-2
"
42'-8"71'-10"
132'-6"
38
'-6
"
5'-0"4'-0
"
18'-0"
6'-2
"
7'-4"
7'-6
"8
'-6
"8
'-6
"
17
'-0
"
S01
S02
C02 C04 C07 C09
S03
C01
S04
9'-0
"
7'-4"
ELEV.
BASEMENT PARKINGTYPE-1A, NFPA 13
(≥98" VERTICAL CLEARANCE)13 PARKING SPACES
4 STANDARD, 9 COMPACT
UP
UP
RAMP TO 1ST FLOOR
7'-6" 10'-10" 9'-2" 5'-10" 9'-2" 7'-6" 7'-6" 7'-6"
15
'-0
"
15
'-0
"
STAIR-1
UP
24'-10" 20'-2"
1'-0"
25'-10" 1'-0" 7'-11" 10'-7" 60'-3"2'-3"
150'-0"
42
'-6
"
5'-3
"
43
'-9
"
6'-3
"
BICYCLE PARKING
BICYCLE
REPAIR
SPACE
(92 S.F.)
ELEC./
MECH.
ROOM
TOTAL 19 STALLS
26'-0"
27
'-5
"
8'-0" HI. W.I.
AUTOMATIC GATE W/
REMOTE CONTROL
7'-2" CLR. HT. FOR
OPENING
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-9
B-1
0
B-1
1
B-1
2
B-1
3
B-1
4
B-1
5
B-1
6
B-1
7
B-1
8
B-1
9
STAIR-3
G2
G6
G3
G4
EXIT TRAVEL
EGRESS TRAVEL:103'-0"
D
IA
G
O
N
A
L
D
IS
T
A
N
C
E
:
1
3
7
'-
1
"
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
SCALE: 1/8"=1'-0"
ACCESSIBLE ENTRANCE SIGN NOTE:
: 8" CONC.. WALL
OR CONC. COLUMN
: 8" C.M.U. WALL
SEE STRUCTURAL DWGS.
SEE STRUCTURAL DWGS.
: EXIT SIGN W/ EMERGENCY LIGHT
A SIGN SHALL BE POSTED IN A CONSPICUOUS PLACE, THE SIGN SHALL BE NO LESS
THAN 17X22 INCHES IN SIZE W/ LETTERING NO LESS THAN 1 INCH IN HEIGHT, WHICH
STATE "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR
PHYSICALLY DISABLED PERSONS MAY BE TOWED AWAY AT OWNER'S EXPENSE.
1. ALL DIMENSIONS ARE FINISH TO FINISH, U.N.O.
2. MIN. VERTICAL CLEARANCE OF 8'-2" WHERE REQUIRED FOR ACCESSIBLE PARKING
SPACES ONLY(7'-0" CLR. ELSEWHERE) SHALL BE CLEAR OF ALL OBSTRUCTIONS,
INCLUDING BEAMS, SPRINKLER HEADS, PIPING, ETC.
3. MAXIMUM DRIVEWAY SLOPE SHALL NOT EXCEED 20%. MAXIMUM DRIVEWAY CROSS
SLOPE IS 10%. MAXIMUM SLOPE WITHIN PARKING AREA IS 5%.
4. DOUBLE STRIPING OF STALLS SHALL BE PER ZONING CODE SECTION 12.21A5,
CHART NO. 5.
5. TANDEM PARKING STALLS SHALL BELONG TO THE SAME UNIT.
6. THE ELECTRICAL SYSTEM SHALL HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT FULL RATED AMPERAGE BASED ON LEVEL 2
EVSE. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
7. EGRESS COURTS LESS THAN 10 FT. IN WIDTH SHALL HAVE EGRESS COURT WALLS
NOT LESS THAN 1-HR FIRE-RESISTANCE RATED CONSTRUCTION; OPENINGS WITHIN
SUCH WALLS SHALL BE PROTECTED BY OPENING PROTECTIVES NOT LESS THAN 3/4
HOUR. (1027.4.2)
8. THE MAXIMUM FLAME-SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED FOLLOWING:
A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS
INSTALLED IN VERTICAL EXITS.
B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS
INSTALLED IN HORIZONTAL EXITS.
C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS
INSTALLED IN ANY OTHER LOCATION.
9. THE ELECTRICAL SYSTEM SHALL HAVE SIFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT THE FULL RATED AMPERAGE OF THE
EVSE. PLAN DESIGN SHALL BE BASED UPON A 40-AMPERE MINIMUN BRANCH
CIRCUIT. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
10. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE
OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV
CHARGING PURPOSES AS EV CAPABLE IN ACCORDANCE WITH THE LOS ANGELES
ELECTRICAL CODE.
11. ALL WASH AND DRYERS ARE FRONT LOADED.
OVER CONCRETE DECK WATERPROOFING
A. BELOW TILE
* INSTALL 3 COATS OR 90 MILS OF FLUID APPLIED ELASTOMERIC MEMBRANE SUCH
AS PACIFIC POLYMERS' ELASTO-DECK 5500 (LA.R.R #24028)
* BROADCAST SAND ONTO FINAL COAT OR INSTALL PROTECTION COURSE SUCH AS
MlRADRI 200V OR ROOFING CAP SHEET.
B. NO TILE:
* INSTALL PACIFIC POLYMERS' ELASTO-DECK "5000X2" (L.A.R.R. #24208) AS PER
MANUFACTURER'S SPECIFICATION.
WATER PROOFING NOTES:
A7.1
: # OF STANDARD PARKING
: # OF COMPACT PARKING
1. TITLE 24 ENERGY CALCULATIONS SHALL BE SUBMITTED TO MECHANICAL PLAN
CHECK DIVISION FOR A SEPARATE APPROVAL.
TITLE 24 ENERGY NOTES:
: X 4 STUDS EXTERIOR WALL
: PARKING STALLS W/ PROVISIONS FOR FUTURE
INSTALLATION OF ELECTRIC VEHICLE SUPPLY EQUIPMENT.
ONLY UNDERGROUND RACEWAYS AND RELATED
UNDERGROUND EQUIPMENT ARE REQUIRED TO BE
INSTALLED AT THE TIME OF CONSTRUCTION. A LABEL
STATING 'EV CAPABLE' SHALL BE POSTED IN A CONSPICUOUS
PLACE AT THE SERVICE PANEL OR SUBPANEL AND THE EV
CHARGING SPACE. (4.106.4.2) SEE BELOW FOR ADDTIONAL
NOTES.
A2.0
BASEMENT PLAN
FLOOR PLAN
BASEMENT
NOTES
STD
STD
STD
STD
EV
STD
KIN
GS
LE
Y D
R.
4TH ST.
DRIVERAMP DOWN TO BASEMENT
TRANSFORMER
6FT. X 4FT.SCHINDLER 3300
STD
GENERATOR
1ST FLOOR PARKINGTYPE-1A, NFPA-13
(≥98" VERTICAL CLEARANCE)12 PARKING SPACES
4 STANDARD, 1 ADA, 1 EV, 6 COMPCT
S01
LINE OF BUILDING ABOVE
STAIR-1
STAIR-2
6"
29
'-8
"
10
"
18
'-1
0"
40'-8" 15'-3"
11"
150'-0"
48
'-6
"
44
'-2
"
134'-3" 15'-1"
ELEV.
UP
82'-3"
18'-0"
STANDARD TYP.
2'-4
"
8'-6
"
ST
AN
DA
RD
TY
P.
7'-6"
A4.0
1
A4.0
1
A4.1
1
A4.1
1
9'-0
"8
'-0
"
11'-10"
REAR SETBACK
9'-2" 7'-6"9'-2"7'-6"
S02
S03 S04
7'-6"
ADA
7'-6" 7'-6"
C01 C02 C03 C04 C05 C06
9'-0
"
12
'-0
"1
7'-2
"1
5'-0
"
8'-6"45'-5"36'-5"11'-5"
3'-6"
4'-0
"
10
"
10
'-4
"
UP
DN
8'-6"
8'-4"
10
'-4
"
DN
DN
RAMP TO BASEMENT
58
'-2
"
12
'-0
"
113'-11"
7'-9
"
12
'-1
0"
5'-2
"
1'-7
"
6'-6
"
7'-8
"
2'-1
1"
15'-0"
28'-0"
17'-6"
LOBBY
(283 S.F.)
TRASH
MAILBOXES
25
'-0
"
1/4
" P
ER
F
T.
MA
X. S
LO
PE
1/4
" P
ER
F
T.
MA
X. S
LO
PE
20% SLOPE10% SLOPE
10% SLOPE
1
A6.0
1
A6.0
(N) TREE
MIN. 24" BOX. (TYP.)
(N) TREE
MIN. 24" BOX. (TYP.)
LANDSCAPE
PLANTER
LANDSCAPE
W05
EXIT
EXIT
EXIT
2-HR. SHAFT
ACCESSIBILITY
PATH OF TRAVEL
2-HR.SHAFT
2-HR.SHAFT
G1
W04W04
W04
W04
G6
G3
G3
G10
G5
1
2
" MAX.
1
2
" M
AX
.
1
2
" M
AX
.
RECYCLE
10'-2"
30 X48
CLEAR
FUTURE EV
INSTALLATION
REACHABLE RANGE
48" MAX. AND 15" MIN.
6'-0
"
(N) TREE
MIN. 24" BOX. (TYP.)
(N) SCREENING
VEGETATION
LANDSCAPE
LANDSCAPE
PLANTER
(E) FIRE
HYDRANT
(N) TREE
MIN. 24" BOX. (TYP.)
(N) F.D.C
3
1
'-8
"
6'-9"
4'-1
1"
3'-6"
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
SCALE: 1/8"=1'-0"
LEGEND
NOTES:
ACCESSIBLE ENTRANCE SIGN NOTE:
: 8" CONC.. WALL
OR CONC. COLUMN
: 8" C.M.U. WALL
SEE STRUCTURAL DWGS.
SEE STRUCTURAL DWGS.
: EXIT SIGN W/ EMERGENCY LIGHT
A SIGN SHALL BE POSTED IN A CONSPICUOUS PLACE, THE SIGN SHALL BE NO LESS
THAN 17X22 INCHES IN SIZE W/ LETTERING NO LESS THAN 1 INCH IN HEIGHT, WHICH
STATE "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR
PHYSICALLY DISABLED PERSONS MAY BE TOWED AWAY AT OWNER'S EXPENSE.
1. ALL DIMENSIONS ARE FINISH TO FINISH, U.N.O.
2. MIN. VERTICAL CLEARANCE OF 8'-2" WHERE REQUIRED FOR ACCESSIBLE PARKING
SPACES ONLY(7'-0" CLR. ELSEWHERE) SHALL BE CLEAR OF ALL OBSTRUCTIONS,
INCLUDING BEAMS, SPRINKLER HEADS, PIPING, ETC.
3. MAXIMUM DRIVEWAY SLOPE SHALL NOT EXCEED 20%. MAXIMUM DRIVEWAY CROSS
SLOPE IS 10%. MAXIMUM SLOPE WITHIN PARKING AREA IS 5%.
4. DOUBLE STRIPING OF STALLS SHALL BE PER ZONING CODE SECTION 12.21A5,
CHART NO. 5.
5. TANDEM PARKING STALLS SHALL BELONG TO THE SAME UNIT.
6. THE ELECTRICAL SYSTEM SHALL HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT FULL RATED AMPERAGE BASED ON LEVEL 2
EVSE. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
7. EGRESS COURTS LESS THAN 10 FT. IN WIDTH SHALL HAVE EGRESS COURT WALLS
NOT LESS THAN 1-HR FIRE-RESISTANCE RATED CONSTRUCTION; OPENINGS WITHIN
SUCH WALLS SHALL BE PROTECTED BY OPENING PROTECTIVES NOT LESS THAN 3/4
HOUR. (1027.4.2)
8. THE MAXIMUM FLAME-SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED FOLLOWING:
A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS
INSTALLED IN VERTICAL EXITS.
B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS
INSTALLED IN HORIZONTAL EXITS.
C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS
INSTALLED IN ANY OTHER LOCATION.
9. THE ELECTRICAL SYSTEM SHALL HAVE SIFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT THE FULL RATED AMPERAGE OF THE
EVSE. PLAN DESIGN SHALL BE BASED UPON A 40-AMPERE MINIMUN BRANCH
CIRCUIT. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
10. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE
OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV
CHARGING PURPOSES AS EV CAPABLE IN ACCORDANCE WITH THE LOS ANGELES
ELECTRICAL CODE.
11. ALL WASH AND DRYERS ARE FRONT LOADED.
12. SLIP RESISTANT FLOOR FINISH PROVIDED.
OVER CONCRETE DECK WATERPROOFING
A. BELOW TILE
* INSTALL 3 COATS OR 90 MILS OF FLUID APPLIED ELASTOMERIC MEMBRANE SUCH
AS PACIFIC POLYMERS' ELASTO-DECK 5500 (LA.R.R #24028)
* BROADCAST SAND ONTO FINAL COAT OR INSTALL PROTECTION COURSE SUCH AS
MlRADRI 200V OR ROOFING CAP SHEET.
B. NO TILE:
* INSTALL PACIFIC POLYMERS' ELASTO-DECK "5000X2" (L.A.R.R. #24208) AS PER
MANUFACTURER'S SPECIFICATION.
WATER PROOFING NOTES:
A7.1
: # OF STANDARD PARKING
: # OF COMPACT PARKING
1. TITLE 24 ENERGY CALCULATIONS SHALL BE SUBMITTED TO MECHANICAL PLAN
CHECK DIVISION FOR A SEPARATE APPROVAL.
TITLE 24 ENERGY NOTES:
: X 4 STUDS EXTERIOR WALL
: PARKING STALLS W/ PROVISIONS FOR FUTURE
INSTALLATION OF ELECTRIC VEHICLE SUPPLY EQUIPMENT.
ONLY UNDERGROUND RACEWAYS AND RELATED
UNDERGROUND EQUIPMENT ARE REQUIRED TO BE
INSTALLED AT THE TIME OF CONSTRUCTION. A LABEL
STATING 'EV CAPABLE' SHALL BE POSTED IN A CONSPICUOUS
PLACE AT THE SERVICE PANEL OR SUBPANEL AND THE EV
CHARGING SPACE. (4.106.4.2) SEE BELOW FOR ADDTIONAL
NOTES.
A2.1
1ST FLOOR PLAN
FLOOR PLAN
1ST
RIGHT TURN ONLY + NO LEFTA
1. UNDER KITCHEN SINKS PROVIDE REMOVABLE
CABINETS & FINISHED FLOORINGS.
2. ALL KITCHEN SHALL HAVE LIGHTINGS AND HOOD VENTILATIONS.
SEE ELEC. & MECH. PLANS.
3. KITCHEN COUNTERTOPS SHALL BE MADE OF GRANITE IN ALL UNITS.
4. ALL COUNTER TOPS USE GRANITE SLAB. (TYP.)
KITCHEN AND BATHROOM NOTES:
DW
DW
DWDW
DW
SCHINDLER 3300
STAIR-1
A4.0
1
A4.0
1
A4.1
1
A4.1
1
CLO
SE
T
CLO
SE
T
CLO
SE
T
CLO
SE
T
CLOSET
CLOSET
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
LIVING
LIVING
LIVING
LIVING
LIVING
STAIR-2
BED RM.BED RM.
BED RM.
BED RM.
BED RM.
BED RM.
BED RM.
BED RM.
BED RM.
BED RM.
# 02
2BED/2BATH
728 SQ. FT.
# 01
2BED/2BATH
729 SQ. FT.
# 03
2BED/2BATH
732 SQ. FT.
# 04
2BED/2BATH
738 SQ. FT.
# 05
2BED/2BATH
736 SQ. FT.
ELEV.
W/D
W/D
W/D
CLOSET
CLOSET
W/DCLO
SE
T
CLOSET
CLO
SE
T
9'-0"
6'-5" 10'-6" 20'-6" 13'-3"
50'-8"
13'-8" 18'-10" 15'-8" 6'-0" 9'-0"
63'-2"
122'-10"
17'-8"
1'-7"
7'-0"
9'-10"
16'-10"
38'-6"
17'-8"
9'-5"
11'-5"
20'-10"
38'-6"
26'-6" 12'-9"
39'-3"
10'-9" 19'-9" 10'-4"
40'-10"
10'-9" 19'-1" 12'-11"
42'-9"
122'-10"
4'-0"
5'-2"
5'-0"
W/D
9'-4"
8'-3"
10'-8"
9'-6"
11'-0"
10'-6"
9'-8"
10'-6"
9'-6"
UP DN
UP
DN
D
IA
G
O
N
A
L
D
IS
T
A
N
C
E
:
1
2
8
'-
9
"
116'-4" > 42'-10"(1/3 OF DIAGONAL DISTANCE)
TRASH
CHUTE
W03 W01
W02
W01
W03W02
W03
1
A6.0
1
A6.0
COMMON PATH OF
EGRESS TRAVEL:101'-0"
COMMON PATH OF
EGRESS TRAVEL:48'-5"
2-HR. SHAFT
2-HR.SHAFT
2-HR.SHAFT
2ND FLOOR STAIR LINE
SEE STAIR ENLARGED PLAN
G6
G3
G3
G7G7
W03 W03 W03
W03 W03 W03 W03
BALCONY
BALCONY
BALCONY
1HR. FIRE RATED CORRIDOR
D4
D1
D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D3
D3
D3
D3
D3D3
D3
D3
D4
D5
D5
D4
D4
D5
D7
D7
D7 D7
D6
D5
D4
D5
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
CLOSET
9'-10"
STG.
STG.
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
SCALE: 1/8"=1'-0"
LEGEND
NOTES:
ACCESSIBLE ENTRANCE SIGN NOTE:
: 8" CONC.. WALL
OR CONC. COLUMN
: 8" C.M.U. WALL
SEE STRUCTURAL DWGS.
SEE STRUCTURAL DWGS.
: EXIT SIGN W/ EMERGENCY LIGHT
A SIGN SHALL BE POSTED IN A CONSPICUOUS PLACE, THE SIGN SHALL BE NO LESS
THAN 17X22 INCHES IN SIZE W/ LETTERING NO LESS THAN 1 INCH IN HEIGHT, WHICH
STATE "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR
PHYSICALLY DISABLED PERSONS MAY BE TOWED AWAY AT OWNER'S EXPENSE.
1. ALL DIMENSIONS ARE FINISH TO FINISH, U.N.O.
2. MIN. VERTICAL CLEARANCE OF 8'-2" WHERE REQUIRED FOR ACCESSIBLE PARKING
SPACES ONLY(7'-0" CLR. ELSEWHERE) SHALL BE CLEAR OF ALL OBSTRUCTIONS,
INCLUDING BEAMS, SPRINKLER HEADS, PIPING, ETC.
3. MAXIMUM DRIVEWAY SLOPE SHALL NOT EXCEED 20%. MAXIMUM DRIVEWAY CROSS
SLOPE IS 10%. MAXIMUM SLOPE WITHIN PARKING AREA IS 5%.
4. DOUBLE STRIPING OF STALLS SHALL BE PER ZONING CODE SECTION 12.21A5,
CHART NO. 5.
5. TANDEM PARKING STALLS SHALL BELONG TO THE SAME UNIT.
6. THE ELECTRICAL SYSTEM SHALL HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT FULL RATED AMPERAGE BASED ON LEVEL 2
EVSE. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
7. EGRESS COURTS LESS THAN 10 FT. IN WIDTH SHALL HAVE EGRESS COURT WALLS
NOT LESS THAN 1-HR FIRE-RESISTANCE RATED CONSTRUCTION; OPENINGS WITHIN
SUCH WALLS SHALL BE PROTECTED BY OPENING PROTECTIVES NOT LESS THAN 3/4
HOUR. (1027.4.2)
8. THE MAXIMUM FLAME-SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED FOLLOWING:
A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS
INSTALLED IN VERTICAL EXITS.
B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS
INSTALLED IN HORIZONTAL EXITS.
C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS
INSTALLED IN ANY OTHER LOCATION.
9. THE ELECTRICAL SYSTEM SHALL HAVE SIFFICIENT CAPACITY TO SIMULTANEOUSLY
CHARGE ALL DESIGNATED EV SPACES AT THE FULL RATED AMPERAGE OF THE
EVSE. PLAN DESIGN SHALL BE BASED UPON A 40-AMPERE MINIMUN BRANCH
CIRCUIT. A SEPARATE ELECTRICAL PERMIT IS REQUIRED.
10. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE
OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV
CHARGING PURPOSES AS EV CAPABLE IN ACCORDANCE WITH THE LOS ANGELES
ELECTRICAL CODE.
11. ALL WASH AND DRYERS ARE FRONT LOADED.
12. SLIP RESISTANT FLOOR FINISH PROVIDED.
OVER CONCRETE DECK WATERPROOFING
A. BELOW TILE
* INSTALL 3 COATS OR 90 MILS OF FLUID APPLIED ELASTOMERIC MEMBRANE SUCH
AS PACIFIC POLYMERS' ELASTO-DECK 5500 (LA.R.R #24028)
* BROADCAST SAND ONTO FINAL COAT OR INSTALL PROTECTION COURSE SUCH AS
MlRADRI 200V OR ROOFING CAP SHEET.
B. NO TILE:
* INSTALL PACIFIC POLYMERS' ELASTO-DECK "5000X2" (L.A.R.R. #24208) AS PER
MANUFACTURER'S SPECIFICATION.
WATER PROOFING NOTES:
A7.1
: # OF STANDARD PARKING
: # OF COMPACT PARKING
1. TITLE 24 ENERGY CALCULATIONS SHALL BE SUBMITTED TO MECHANICAL PLAN
CHECK DIVISION FOR A SEPARATE APPROVAL.
TITLE 24 ENERGY NOTES:
: X 4 STUDS EXTERIOR WALL
: PARKING STALLS W/ PROVISIONS FOR FUTURE INSTALLATION OF ELECTRIC
VEHICLE SUPPLY EQUIPMENT. ONLY UNDERGROUND RACEWAYS AND RELATED
UNDERGROUND EQUIPMENT ARE REQUIRED TO BE INSTALLED AT THE TIME OF
CONSTRUCTION. A LABEL STATING 'EV CAPABLE' SHALL BE POSTED IN A
CONSPICUOUS PLACE AT THE SERVICE PANEL OR SUBPANEL AND THE EV
CHARGING SPACE. (4.106.4.2) SEE BELOW FOR ADDTIONAL NOTES.
A2.2
2ND-4TH FLOOR PLAN
2ND - 4TH
FLOOR PLAN
1. UNDER KITCHEN SINKS PROVIDE REMOVABLE
CABINETS & FINISHED FLOORINGS.
2. ALL KITCHEN SHALL HAVE LIGHTINGS AND HOOD VENTILATIONS.
SEE ELEC. & MECH. PLANS.
3. KITCHEN COUNTERTOPS SHALL BE MADE OF GRANITE IN ALL UNITS.
4. ALL COUNTER TOPS USE GRANITE SLAB. (TYP.)
5. LOWER SHELVING AT 48" MAX. ARE PROVIDED.
KITCHEN AND BATHROOM NOTES:
DW
DW
DW
DW
SCHINDLER 3300
LIVING
KITCHEN
ELEV.
A4.0
1
A4.0
1
A4.1
1
A4.1
1
A4.0
1
A4.1
1
A4.1
CLOSET
CL
OS
ET
CL
OS
ET
BATH
KITCHEN
LIVING
BED RM.BED RM.
BED RM.BED RM.
BED RM.
BED RM.
CL
OS
ET
# 02
2BED/2BATH
728 SQ. FT.
# 01
2BED/2BATH
729 SQ. FT.
# 503
3BED/2BATH
1,102 SQ. FT.
#504
3BED/2BATH
1,107 SQ. FT.
STAIR-1
CL
OS
ET
CL
OS
ET
CLOSET
BATH
BATH
BATH
BATH
KITCHEN
KITCHEN
LIVING
LIVING
STAIR-2
BED RM.BED RM.
BED RM.
BED RM.
W/D
9'-0"
6'-5" 10'-6" 20'-6" 13'-3"
50'-8"
13'-8" 18'-10" 15'-8" 6'-0" 9'-0"
63'-2"
122'-10"
W/D
9'-6"
11
'-0
"
10'-6"
8'-6
"
10'-6"
10
'-1
0"
UP DN
CL
OS
ET
BATH BATH
CL
OS
ET
W/D
W/D
17
'-8
"
10
'-4
"1
0'-6
"
20
'-1
0"
38
'-6
"
17
'-8
"4
'-0
"
6'-1
1"
9'-1
1"
16
'-1
0"
38
'-6
"
16'-7" 6'-8" 23'-8" 12'-9" 13'-2" 24'-3" 12'-10" 12'-11"
59'-8" 63'-2"
10'-3"
3'-4
"
4'-0
"
3'-4
"
10'-1"10'-0" 10'-0"
4'-6
"
5'-4
"
UPDN
STORAGE
D
IA
G
O
N
A
L
D
IS
T
A
N
C
E
:
1
2
8
'-
9
"
116'-4" > 42'-10"(1/3 OF DIAGONAL DISTANCE)
BALCONYBALCONY
COMMON PATH OF
EGRESS TRAVEL:78'-3"
COMMON PATH OF
EGRESS TRAVEL:69'-0"
1
A6.0
1
A6.0
2-HR. SHAFT
2-HR.SHAFT
2-HR.SHAFT
G6
G3
G3
G7G7
W03 W01W03 W03 W03
W02
W02
W03
W03
W03 W03 W03 W03
1HR. FIRE RATED CORRIDOR
D1 D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D3
D3
D3
D2
D2 D3D3
D4
D4
D5
D5
D5
D4
D4
D5
D5
D5 D5
D6
D7
D7
D7
2'-0"
2'-0"
2'-0
"
2'-0
"
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
30 X48
CLEAR
42 X52
CLEAR
BATH
STG.
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
SCALE: 1/8"=1'-0"
A2.3
5TH FLOOR PLAN
: FUTURE FOLDABLE GRAB BAR LOCATION. SEE 6,12,13/A8.7.
LEGEND
A7.1
2B
: 1-HR. X 4 STUDS EXTERIOR WALL
: 2-HR. SHAFT WALL
3B
A7.1
X6 PLATE, X4 STAGGERED
: PARTY WALL
W/ DRAFT STOP AT ATTIC
A7.1
3A
A7.1
3C
: 1-HR. CORRIDOR WALL
: X 4 STUDS INTERIOR WALL
3D
A7.1
A7.1
3C
: 1-HR. X 4 STUDS INTERIOR WALL
SOUND RATED.
NON-SOUND RATED.
: HARDWIRED SMOKE DETECTORS W/ BATTERY BACKUP & LOW BATTERY SIGNAL. SEE
ELEC. PLANS.
: 30" WORK COUNTER W/ REMOVABLE BASE CABINETS AND FINISHED FLOOR
UNDERNEATH
: 15" BREAD BOARD
: FUTURE WALL-HUNG GRAB BAR LOCATION; BACKING 32" TO 38" ABOVE FLR. MIN. 6"
NOMINAL IN HT. MIN. 40" IN LENGTH AT BACK OF TOILET. FOR SIDE OF TOILET, 12" MAX.
FROM REAR WALL & TO EXTEND MIN. 26" IN FRONT OF TOILET FIXTURE.
SEE 6,12,13/A8.7.
: APPROVED LOW-LEVEL EXIT SIGN
: DIRECTIONAL EXIT SIGN W/ EMERGENCY LIGHT W/ MIN. 6" HT. X 3/4" STROKE BLOCK
LETTERS ON CONTRASTING BACKGROUND. MAX. SPACING BETWEEN SIGNS IS 100'.
: 5 MINUTES MIN. AIR EXCHANGE FAN. SEE MECH. PLANS.
BATHROOM EXHAUST FANS SHALL COMPLY WITH THE FOLLOWING:
i. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO
THE OUTSIDE OF THE BUILDING.
ii. FANS NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION
SYSTEM MUST BE CONTROLLED BY A HUMIDITY CONTROL. (CAL GREEN 4.506.1)
: CARBON MONOXIDE ALARM
1. PROVIDE 70 INCH H. NON-ABSORBENT WALL ADJACENT TO SHOWER AND
APPROVED SHATTER - RESISTANT MATERIALS FOR SHOWER ENCLOSURE.
2. WATER CLOSETS SHALL BE OF LOW CONSUMPTION.
3. PROVIDE AN APPROVED GRAFFITI-RESISTANT FINISH FOR THE FIRST 9 FEET OF
EXTERIOR WALLS: BY DUNN EDWARDS, LARR #RR25162-T.
4. DRAFT STOP SHALL BE PROVIDED WITHIN A CONCEALED FLOOR-CEILING ASSEMBLY
FORMED OF COMBUSTIBLE CONSTRUCTION.
5. DRAFT STOP SHALL BE PROVIDED WITHIN ATTICS, OVERHANGS AND SIMILAR
CONCEALED SPACES FORMED OF COMBUSTIBLE CONSTRUCTION.
6. ALL DIMENSIONS ARE FINISH TO FINISH, U.N.O.
7. HYDRO PASSENGER ELEVATOR ±2500 LBS - GURNEY SIZE BY 'OTIS ELEVATOR'.
8. FOR WATER PROOFING SYSTEM REFER TO WATER PROOFING NOTES ON A1.0.
9. ALL KITCHENS SHALL HAVE LIGHTING AND HOOD VENTILATION. SEE ELEC. & MECH.
PLANS.
10. DRYER VENT SHALL NOT EXCEED 14'-0" LENGTH A MIN. OF 2 ELBOWS (90d).
11. VERIFY THAT WALL FRAMING WILL ALLOW FOR A 4" VENT ALSO VERIFY THIS
CONDITION AS VENT PASSES THROUGH DOUBLE TOP PLATE.
12. TEMPORARY PEDESTRIAN PROTECTION SHALL BE PROVIDED AS REQUIRED BY
SECTION 303.7.
13. THIS BUILDING AND GARAGE MUST BE EQUIPPED WITH AN AUTOMATIC FIRE
EXTINGUISHING SYSTEM.
14. SOLID JOINT SHALL BE USED IN THE BATHTUB TRAP.
15. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH
NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH
SEC. 1205.2 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO
PROVIDED AN AVERAGE ILLUMINATION OF 10 FOOT-CANDLES OVER THE AREA OF THE
ROOM AT A HEIGHT OF 30 IN. ABOVE THE FLOOR LEVEL. (1205.1, 1205.3)
16. THE MAXIMUM FLAME-SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED FOLLOWING:
A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS
INSTALLED IN VERTICAL EXITS.
B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS
INSTALLED IN HORIZONTAL EXITS.
C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS
INSTALLED IN ANY OTHER LOCATION.
17. PROVIDE AN APPROVED STAIRWAY SIGN INDICATING FLOOR LEVEL, TERMINUS OF
THE TOP AND BOTTOM OF THE STAIR AND
THE IDENTIFICATION NUMBER OF THE STAIR. IT SHALL BE LOCATED APPX. 5 FT.
ABOVE THE FLOOR LANDING AND BE READILY VISIBLE WHEN THE STAIR DOORS ARE IN
AN OPEN OR CLOSED POSITION. (1022.9)
18. ALL WASH AND DRYERS ARE FRONT LOADED.
19. SLIP RESISTANT FLOOR FINISH PROVIDED.
NOTES:
: EGRESS WINDOW; SEE DETAIL AND NOTE ON A5.1.
5TH
FLOOR PLAN
1. UNDER KITCHEN SINKS PROVIDE REMOVABLE
CABINETS & FINISHED FLOORINGS.
2. ALL KITCHEN SHALL HAVE LIGHTINGS AND HOOD VENTILATIONS.
SEE ELEC. & MECH. PLANS.
3. KITCHEN COUNTERTOPS SHALL BE MADE OF GRANITE IN ALL UNITS.
4. ALL COUNTER TOPS USE GRANITE SLAB. (TYP.)
5. LOWER SHELVING AT 48" MAX. ARE PROVIDED.
KITCHEN AND BATHROOM NOTES:
SCHINDLER 3300
ROOF DECK 1
CLASS A
OPEN SPACE
(663 SQ.FT.)
1/4":12
MA
X S
LO
PE
1/4":12
MA
X S
LO
PE
1/4":12
MA
X S
LO
PE
1/4":12
MA
X S
LO
PE
- HVAC -
SEE MECHANICAL
PLAN
ROOF DECK 1
CLASS A
OPEN SPACE
(550 SQ.FT.)
ROOF DECK 1
CLASS A
OPEN SPACE
(550 SQ.FT.)
ROOF DECK 1
CLASS A
OPEN SPACE
(712 SQ.FT.)
PLANTER
(223 SQ.FT.)
PLANTER
(200SQ.FT.)
PLANTER
(223 SQ.FT.)
- HVAC -
SEE MECHANICAL
PLAN
- HVAC -
SEE MECHANICAL
PLAN
STAIR-1
STAIR-2
A4.0
1
A4.0
1
A4.1
1
A4.1
1
ELEV.
DNDN
1
A6.0
1
A6.0
2-HR. SHAFT
2-HR.SHAFT
2-HR.SHAFT
G6
G3
G3
EXIT TRAVEL
EGRESS TRAVEL:73'-0"
11'-5"
42" MIN.
PARAPET
11'-11" 9'-0" 22'-9" 23'-9" 21'-5" 23'-9" 13'-2" 9'-0" 15'-2"
150'-0"
5'-8"
17'-8"
20'-10"
5'-8"
49'-10"
12'-3" 31'-9" 23'-9" 21'-5" 23'-9" 22'-2" 15'-2"
150'-3"
5'-8"
17'-8"
20'-10"
44'-2"
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
SCALE: 1/8"=1'-0"
A2.4
ROOF PLAN
ROOF DRAIN NOTES:
1. ALL ROOF DRAINS MUST CONDUCT TO THE FACE OF THE STR. CURS, UNDER THE
SIDEWALK THROUGH A MIN. 4" C-1 PIPE VIA GRAVITY.
ROOF SPECIFICATIONS:
BUILT-UP ROOFS CLASS 'A'
FOR USE OVER PLYWOOD OR OTHER NAlLABLE DECKS.
ALL ROOF CONSTRUCTION AND COVERING SHALL BE APPLIED TO CHAPTER 15, LOS
ANGELES BUILDING CODE 1996 AMENDMENT
SUMMARY OF MATERIALS PER 100 SQ. FT. OF ROOF AREA:
1) SHEATING PAPER
(WOOD BOARD DECKS ONLY) 1-LAYER
2) BASE SHEET
(JOHN MANVILLE GLASBASE OR EQUAL) 28 LBS 1-LAYER
3) PLY SHEET
(JOHN MANVILLE GLASPLY IV OR EQUAL) 11 LBS 2-LAYER
4) CAP SHEET
MINERAL SURFACED GLASS FIBER FELT
(JOHN MANVILLE GLASKAP OR EQUAL) 12 LBS 1-LAYER
APPLY 25 LBS ASPHALT MOPPING BETWEEN EACH LAYER.
ASPHALT FOR USE AS HOT CEMENT AND MOPPING COAT FOR BUILT-UP ROOF
COVERING SHALL COMPLY WITH LOS ANGELES BUILDING CODE STANDARD. (UL
LABEL)
NOTES:
WATER PROOFING NOTES:
OVER CONCRETE DECK WATERPROOFING
A. BELOW TILE
* INSTALL 3 COATS OR 90 MILS OF FLUID APPLIED ELASTOMERIC MEMBRANE SUCH
AS PACIFIC POLYMERS' ELASTO-DECK 5500 (LARR #24028)
* BROADCAST SAND ONTO FINAL COAT OR INSTALL PROTECTION COURSE SUCH AS
MlRADRI 200V OR ROOFING CAP SHEET.
B. NO TILE:
* INSTALL PACIFIC POLYMERS' ELASTO-DECK "5000X2" (LARR #24208) AS PER
MANUFACTURER'S SPECIFICATION.
1. PROVIDE 70 INCH H. NON-ABSORBENT WALL ADJACENT TO SHOWER AND
APPROVED SHATTER - RESISTANT MATERIALS FOR SHOWER ENCLOSURE.
2. WATER CLOSETS SHALL BE OF LOW CONSUMPTION.
3. PROVIDE AN APPROVED GRAFFITI-RESISTANT FINISH FOR THE FIRST 9 FEET OF
EXTERIOR WALLS: BY DUNN EDWARDS, LARR #RR25162-T.
4. DRAFT STOP SHALL BE PROVIDED WITHIN A CONCEALED FLOOR-CEILING ASSEMBLY
FORMED OF COMBUSTIBLE CONSTRUCTION.
5. DRAFT STOP SHALL BE PROVIDED WITHIN ATTICS, OVERHANGS AND SIMILAR
CONCEALED SPACES FORMED OF COMBUSTIBLE CONSTRUCTION.
6. ALL DIMENSIONS ARE FINISH TO FINISH, U.N.O.
7. HYDRO PASSENGER ELEVATOR ±2500 LBS - GURNEY SIZE BY 'OTIS ELEVATOR'.
8. FOR WATER PROOFING SYSTEM REFER TO WATER PROOFING NOTES ON A1.0
9. ALL KITCHENS SHALL HAVE LIGHTING AND HOOD VENTILATION. SEE ELEC. & MECH.
PLANS.
10. DRYER VENT SHALL NOT EXCEED 14'-0" LENGTH A MIN. OF 2 ELBOWS (90d).
11. VERIFY THAT WALL FRAMING WILL ALLOW FOR A 4" VENT ALSO VERIFY THIS
CONDITION AS VENT PASSES THROUGH DOUBLE TOP PLATE.
12. TEMPORARY PEDESTRIAN PROTECTION SHALL BE PROVIDED AS REQUIRED BY
SECTION 303.7.
13. THIS BUILDING AND GARAGE MUST BE EQUIPPED WITH AN AUTOMATIC FIRE
EXTINGUISHING SYSTEM.
14. SOLID JOINT SHALL BE USED IN THE BATHTUB TRAP.
15. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH
NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH
SEC. 1205.2 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO
PROVIDED AN AVERAGE ILLUMINATION OF 10 FOOT-CANDLES OVER THE AREA OF THE
ROOM AT A HEIGHT OF 30 IN. ABOVE THE FLOOR LEVEL. (1205.1, 1205.3)
16. THE MAXIMUM FLAME-SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED FOLLOWING:
A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS
INSTALLED IN VERTICAL EXITS.
B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS
INSTALLED IN HORIZONTAL EXITS.
C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR
MATERIALS INSTALLED IN ANY OTHER LOCATION.
17. PROVIDE AN APPROVED STAIRWAY SIGN INDICATING FLOOR LEVEL, TERMINUS OF
THE TOP AND BOTTOM OF THE STAIR AND THE IDENTIFICATION NUMBER OF THE
STAIR. IT SHALL BE LOCATED APPX. 5 FT. ABOVE THE FLOOR LANDING AND BE
READILY VISIBLE WHEN THE STAIR DOORS ARE IN AN OPEN OR CLOSED POSITION.
(1022.9)
18. PROVIDE STAIRWAY ILLUMINATION. MIN.1 FOOT-CANDLE AT TREAD RUNS.
(1205.4)
: SOLAR ZONE AREA
TOTAL ROOF AREA : , SQ.FT.
15% OF ROOF AREA : SQ.FT.
PROVIDE SOLAR ZONE AREA : , SQ.FT.
SOLAR ZONE AREA
1. FOR RESIDENTIAL BUILDINGS, OTHER THAN ONE- AND TWO-FAMILY DWELLINGS,
COMPLY WITH THE FOLLOWING:
a. DESIGNATE ON THE ROOF PLAN SOLAR ZONE AREA(S) WITH TOTAL AREA EQUAL TO
OR GREATER THAN 15% OF THE BUILDING'S ROOF AREA.
THE SOLAR ZONE SHALL BE COMPRISED OF AREAS THAT HAVE NO DIMENSION LESS
THAN 5 FEET AND EACH AREA SHALL NOT BE LESS THAN:
i. 80 SQ FT FOR ROOF AREAS OF 10,000 SQ FT OR LESS.
ii. 160 SQ FT FOR ROOF AREAS OVER 10,000 SQ FT.
c. THE SOLAR ZONE SHALL BE FREE OF OBSTRUCTIONS AND BE SETBACK AT LEAST
TWO TIMES THE HEIGHT OF ANY OBSTRUCTION, INCLUDING BUT NOT LIMITED TO,
VENTS, CHIMNEYS, AND EQUIPMENT.
d. FOR ROOF SLOPES < 2:12, A MINIMUM 4 FOOT CENTER LINE AXIS PATHWAY SHALL
BE PROVIDED ON BOTH AXES OF THE ROOF.
e. FOR ROOF SLOPES < 2:12, A MINIMUM 4 FOOT STRAIGHT LINE PATHWAY SHALL BE
PROVIDED FROM THE ACCESS PATH TO ROOF STANDPIPES, ROOF ACCESS HATCHES,
SKYLIGHTS AND/OR VENTILATION HATCHES.
f. FOR ROOF SLOPES < 2:12, THE SOLAR ZONE SHALL ALLOW FOR A (6-FOOT) (4-FOOT)
WIDE CLEAR PERIMETER ACCESS AROUND THE EDGES OF THE ROOF.
i. PLANS SHALL INDICATE A LOCATION FOR INVERTERS AND METERING
EQUIPMENT AND A PATHWAY FOR ROUTING FROM THE SOLAR ZONE TO THE MAIN
SERVICE PANEL.
j. PLANS SHALL INDICATE A PATHWAY FOR ROUTING OF PLUMBING FROM THE SOLAR
ZONE TO THE WATER-HEATING SYSTEM. (4.211.4,ENERGY CODE §110.10. LAFD
REQUIREMENT NO.96)
SOLAR ZONE NOTES:
DAMP PROOFING MATERIAL ICC-ES-REPORT NO. 1417DECO PRODUCTS,INC.
MATERIAL MANUFACTURER
BORAL ROOFING ICC-ES-REPORT NO. 1783
DECK COATING
ROOFING MATERIAL
ICC-ES-REPORT NO. 1714CROSSFIELD PRODUCTS CORP.
ICC-ES-REPORT NO.
MATERIAL SPECIFICATIONS FOR THE ROOFING PRODUCT
18. PLANS SHALL IDENTIFY THE TYPE OF ROOFING, MANUFACTURER, PRODUCT, AND
COLOR USED. INCORPORATE THE MATERIAL SPECIFICATIONS FOR THE ROOFING
PRODUCT USED AND SHOW THAT IT MEETS THE FOLLOWING MINIMUM SRI VALUE OR
BOTH SOLAR REFLECTANCE AND THERMAL EMITTANCE VALUES:
a. FOR ROOF SLOPES < 2:12: SRI VALUE OF AT LEAST 75 OR BOTH A 3-YEAR
SOLAR REFLECTANCE OF AT LEAST 0.63 AND A THERMAL EMITTANCE OF AT LEAST
0.75.
19. A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT
INDICATING THE INFORMATION FROM ENERGY CODE SECTIONS 110.10(b) THROUGH
110.10(c) SHALL BE PROVIDED TO THE OCCUPANT.
ROOF PLAN
10'-0"
10'-0"
10'-0"
9'-0"
8'-9"
8'-9"
10'-0"
2ND F.F
3RD F.F
4TH F.F
1ST F.F
8'-9"
G.L.
10'-0"
8'-9"
3'-0"
5TH F.F
ROOF
50'-0"
53'-0"
PROPERTY LINE
11'-10"
REAR
SETBACK
15'-0"
FRONT
SETBACK
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
A3.0
ELEVATION
SOUTH (SIDE ELEVATION) 01
SCALE: 1/8"=1'-0"
10'-0"
10'-0"
10'-0"
9'-0"
8'-9"
8'-9"
10'-0"
2ND F.F
3RD F.F
4TH F.F
1ST F.F
8'-9"
G.L.
10'-0"
8'-9"
3'-0"
5TH F.F
ROOF
50'-0"
53'-0"
PROPERTY LINE
5'-7"
SIDE
SETBACK
5'-7"
SIDE
SETBACK
10'-0"
10'-0"
10'-0"
9'-0"
8'-9"
8'-9"
10'-0"
2ND F.F
3RD F.F
4TH F.F
1ST F.F
8'-9"
G.L.
10'-0"
8'-9"
3'-0"
5TH F.F
ROOF
50'-0"
53'-0"
PROPERTY LINE
5'-7"
SIDE
SETBACK
5'-7"
SIDE
SETBACK
EXTERIOR OPENING CALCULATION (T705.8)
FIRE SEPARATION DISTANCE (TO PL): 12'-0"
MAX. ALLOWABLE EXTERIOR WALL OPENING PER FLOOR: 45%
1ST FLOOR
AREA OF EXTERIOR WALL: 385 SF
AREA OF OPENINGS: 200 SF
OPENING %: 52% > 45% (MOD REQ.)
*EFFECTIVE OPENING: 50 SF OR 13%
(AFTER 6' HT CMU PL WALL
AND 1'-6" DRAFT STOP)
2ND-5TH FLOOR, PER FLOOR
AREA OF EXTERIOR WALL: 385 SF
AREA OF OPENINGS: 121 SF
OPENING %: 31% < 45%
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
A3.1
ELEVATION
EAST (FRONT ELEVATION) 01
SCALE: 1/8"=1'-0"
WEST (REAR ELEVATION)02
SCALE: 1/8"=1'-0"
10'-0"
10'-0"
10'-0"
9'-0"
8'-9"
8'-9"
10'-0"
2ND F.F
3RD F.F
4TH F.F
1ST F.F
8'-9"
G.L.
10'-0"
8'-9"
3'-0"
5TH F.F
ROOF
50'-0"
53'-0"
PROPERTY LINE
11'-10"
REAR
SETBACK
15'-0"
FRONT
SETBACK
EXTERIOR OPENING CALCULATION (T705.8)
FIRE SEPARATION DISTANCE (TO PL): 5'-8"
MAX. ALLOWABLE EXTERIOR WALL OPENING PER FLOOR: 25%
1ST FLOOR
AREA OF EXTERIOR WALL: 1230 SF
AREA OF OPENINGS: 710 SF
OPENING %: 58% > 25% (MOD REQ.)
*EFFECTIVE OPENING: 177 SF OR 14%
(AFTER 6' HT CMU PL WALL
AND 1'-6" DRAFT STOP)
2ND-5TH FLOOR, PER FLOOR
AREA OF EXTERIOR WALL: 1230 SF
AREA OF OPENINGS: 300 SF
OPENING %: 24% < 25%
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
A3.2
ELEVATION
NORTH (SIDE ELEVATION) 01
SCALE: 1/8"=1'-0"
WINDOW SCHEDULE
DOOR SCHEDULE
WINDOW TYPE
DOOR TYPE
G1
G2
G6
G5
A
ALUM.
TEMP.GL.
ALUM.
LEVERTYPE HARDWARE
1/4"
1-3/4"
SELF CLOSING
B
3'-6"
SMOKE GUARD, ACTIVATED BY
0.01" P.M.FILM
SMOKE DETECTORS &
6'-8"
INSTALLED PER MANUFACT.
INSTRUCTIONS (LARR#25201, ESR-1136)
-
8'-0"
3'-2" 8'-0"
D1
6'-8" 1-3/8" W.D.H.C
BEDROOM, BATHROOM DOOR
A
VAR.
B
E
3-0"
1/4"
6"
G
3'-0"
5'-0"
B
NOTE:
- ONE OPENABLE WINDOW WITH AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ.FT., MIN. CLEAR 24" HEIGHT AND 20" WIDTH,
AND A SILL HEIGHT NOT OVER 44" ABOVE THE FLOOR IS REQUIRED IN ALL BEDROOMS BELOW THE FOURTH STORY AND
BASEMENT. (1029)
- WHERE GLAZED OPENINGS ARE PROVIDED, AT LEAST 1 IN EVERY ROOM OR SPACE SHALL COMPLY WITH 1138A.4, 30"x48"
CLEAR SPACE, REACH RANGE 15" TO 48", REQUIRED FORCE TO OPERATE NO GREATER THAN 5 POUNDS.
NOTE:
- DOORS SHALL NOT PROJECT MORE THAN 7" INTO THE REQUIRED CORRIDOR WIDTH OR AT LANDINGS WHEN FULLY
OPENED AND NOT MORE THAN 50% IN ANY POSITION. (1008.1.6)
- DOOR HARDWARE 34" TO 44" HIGH, NO MORE THAN 5 POUNDS PRESSURE TO OPERATE.
8'-2" W.I.
AUTOMATIC GARAGE OPENER
1-3/4"
-
W/INTERCOM SYSTEM
TO EACH UNIT
W.I.
E 1-3/4" W.D.S.C.6'-8"3'-0"
MIN. STC 26 RATING
20MIN.
D2
WALK-IN CLOSET DOOR
D3
D4
D5
E
W1
W2
W3
8'-0"
ALUM.
TEMP.GL.
I
2'-10"
8'-2"
10'-0"
6'-8"
C
3'-0" 3'-0"
6'-0"
6'-8" 1-3/8"
W.D.
LOUVERED
WOOD
G 2'-8"
6'-8"4'-9" 1-3/8"
CLOSET DOOR
OVERHUNG SLIDING
H.CH
H
W.D.
6'-8" 1-3/8"
6'-8"
6'-8"
VAR.
K
1/4"
VINYL
TEMP.GL.
VINYL
1-3/4"
8'-0"
K
2'-6"
FL.
FL.
FL.
8'-0"
6'-0"
2'-0"
D 6'-0"
TEMP.GL. EGRESS WINDOW; SEE NOTE.
VINYL
G46'-8"3'-0"
SELF CLOSING
LEVERTYPE HARDWARE,
E
1-3/4" P.M.S.C. 45MIN.
6'-8"
3'-6"
L
45MIN. FIRE-RATED
G3 6'-8"E 1-3/4" P.M.S.C.
SELF CLOSING
PANIC HARDWARE,
45MIN.3'-0"
6'-8"6'-0"
SELF CLOSING
LEVERTYPE HARDWARE,
C 1-3/4"P.M.S.C. 45MIN.
3'-2"
10'-0"
VAR.
6'-0"
6'-0"
2'-0"
8'-0"
LIVING ROOM BALCONY DOOR
8'-0"
6'-4"
6'-8"
VINYL8'-0" FIXED, TEMP.GL.2'-6"C
STORAGE DOOR
LAUNDRY DOOR
6'-4" 2'-0" 6'-0" 2'-0"
10'-0"
8'-0"
2'-6"
6'-0"
VAR
D6
D7
LIVING ROOM BALCONY DOORI
1/4"
VINYL
TEMP.GL.
VINYL
1-3/4"
8'-0"10'-0"
W4VINYL8'-0" FIXED, TEMP.GL.3'-5"C
3'-0"
6'-0"
3'-0"M
M
6'-0"W.I.
1-3/4"W.I. W/ 6'-0" HT. W.I. FENCE
N
3'-8"
1'-6"
3'-0"
1'-6"D
TRASH CHUTE DOOR WITH
3'-0" SST P.M.
-90MIN.
SMOKE AND FIRE DAMPER
D10
G7
7'-10"
CLOSET DOOR
OVERHUNG SLIDING
H.CH
W.D.
KS
K
SHEET TITLE
2
3
1
BLDG.
DATE:
SUBMITTAL
BID DATE:
REVISIONS
PROJECT NO.:
SCALE: AS SHOWN ON PLAN
DRAWN:
SHEET NO.
4
5
PROJECT
These draw
ings and/or specifications are instructions of service
and are the property of K
SK
D
ES
IG
N IN
C. A
ll inform
ation
contained herew
ith is restricted to use on the specified site and
project. F
ederal law
prohibits the reproductive display, sale, or
other disposition of these docum
ents w
ithout the expressed
written perm
ission of K
SK
D
ES
IG
N IN
C.
3435 W
ILS
HIR
E B
LV
D., S
UIT
E 2905
LO
S A
NG
ELE
S, C
A 90010
TE
L1: 213) 388-5807 T
EL2: 213) 386-3693 F
AX
: 213) 386-4052
19
U
NIT
S M
UL
TI R
ES
ID
EN
TIA
L
35
5 S
. K
IN
GS
LE
Y D
R.,
LO
S A
NG
EL
ES
, C
A 9
00
20
2017_R-M_06
A5.0
DOOR & WINDOW SCHEDULE1
SCHEDULEDOOR & WINDOW