l. m. pant, a. k. mohanty nuclear physics division bhabha atomic research centre, mumbai
DESCRIPTION
Indian Industrial Outreach for GEM Foil Development. L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai on behalf of India CMS GEM collaboration. Indian Industrial Outreach (first emails sent in June 2013) Thanks !! - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/1.jpg)
1
L. M. Pant, A. K. Mohanty
Nuclear Physics DivisionBhabha Atomic Research Centre, Mumbai
on behalf of India CMS GEM collaboration
Indian Industrial Outreach for GEM Foil Development
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 2: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/2.jpg)
2L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
Indian Industrial Outreach(first emails sent in June 2013)
Thanks !!
to the initiative taken by Dr. A. K. Mohanty &
support provided by Dr. Archana Sharma
![Page 3: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/3.jpg)
Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
3
Micropack, Bangalore : Visit by BARC on 07 Aug.: Visited CERN in November 2013 for ToT / Licensing: Started with pilot production on Cu and polymide etching
Keerthi Industries Ltd. - Electronics Division,-KIED, Hyderabad : Visit by BARC on 02 Aug.: Visited CERN in October end for ToT / Licensing: Needs artwork from CERN for Cu etching for 10 cm x 10 cm foils
Alpha Pneumatics, Mumbai : : Plans to visit CERN in 2014 for ToT: To start with Cu and dry polymide etching has been initiated
L. M. Pant
Transfer of Technology for GEM foil development to Indian Industries
![Page 4: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/4.jpg)
Micropack BangaloreKeerthi Industries Electronics Division, KIED HyderabadAlpha Pneumatics Mumbai
The Indian industries
L. M. Pant 4Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 5: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/5.jpg)
5L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
Transfer of Technology for GEM foil development to Indian Industries
Recipie
Tools and Equipments
Quality Control and Quality Assurance
Fine tuning of the existing infrastructure
![Page 6: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/6.jpg)
6
Slides from KIED
Electronics DivisionPrinted Circuit Boards
(Flexible, Rigid & Rigid flex) Hyderabad, AP
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 7: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/7.jpg)
7
Slides from KIED
PCBs made by KIED for ALICE, CERN
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 8: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/8.jpg)
8
CMS, CERN : GEM Foil with KIED Slides from KIED
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 9: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/9.jpg)
9
A Pattern of Cu etching on GEM Foil : First trial by KIEDSlides from KIED
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 10: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/10.jpg)
10
Working with India CMS Group / CERN mp
www.micro-pack.com
• Has been associated with CERN projects through Saha Institute of Nuclear Physics since 2011.
• Thin Polyimide GEM foil technology introduced to Micropack by India – CMS team in Aug 2013
- Visit by India CMS team to Micropack to introduce the technology- Requirements of GEM upgrade project for CMS briefed- Scope and need for development of GEM Foil technology in India- Process Brief- Feasibility discussions
Slides from Micropack
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 11: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/11.jpg)
11
Processing Trials mp
www.micro-pack.com
Basic feasibility trials conducted at Micropack as per the process brief provided by BARC
Encouraging results with polyimide etching / copper electro etching
Decision taken to pursue the technology for the development of GEM foils
Visit to CERN, Geneva planned
Slides from Micropack
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 12: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/12.jpg)
12
Discussions at CERN mp
www.micro-pack.com
- Visited CERN , Geneva on 15th Nov 2013- Discussions with Dr. Rui De Oliveira
Dr. Andrey Marinov Dr. Tim Tsarfati, Technology Transfer Officer
- Draft TOT agreement shared by Dr. Tsarfati- TOT agreement terms agreed by Micropack- 2 year road map as per the TOT finalised in December 13.
Slides from Micropack
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 13: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/13.jpg)
Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
13
MICROPACK ROADMAP
S.No. Item
1Q 2Q 3Q 4Q 1Q 2Q 3Q 4Q
2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
1 License Agreement
2 100 x 100 Fabrication and QC Validation
- Rebuild equipments/utility for GEM Foil - Prepare raw materials(FCCL, mixed chemi-cals) - develop the prototype
- QC validate the prototype @COMPANY
- QC validate the prototype @COMPANY
3 100 x 100 Routine and standard production , 300 x 300 R&D
- 100 x 100 routine & standard production
- develop the prototype of 300 x 300 - QC validate the prototype @COMPANY/CERN
4 300 x 300 Routine and standard production , 500 x 500 R&D
- 300 x 300 routine & standard production
- develop the prototype of 500 x 500 - QC validate the prototype @COMPANY/CERN Slides fro
m Micropack
L. M. Pant
![Page 14: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/14.jpg)
14
Plasma Etching : advantages over conventional wet chemical process
• Gas Phase reaction - clean and precise.• It is possible to etch copper and Kapton in succession.• Photo-resist mask can be removed by Ashing ( O2 plasma)• Change of etchants through switching of MFC channels• Etch process can be programmed to etch many layers one after other .• End point detection by OES (optical emission spectroscopy)• Excellent control over Differential etch rate between copper and
KAPTON • DC bias : controlled ion energy for directional etching • Anisotropy : Vertically profiled etched grooves with Large aspect
ratio can be achieved possible. • Very low undercutting
Slides from Alpha Pneumatics
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 15: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/15.jpg)
15
Plasma etching at Mumbai factory
Slides from Alpha Pneumatics
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 16: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/16.jpg)
16
RF Plasma at 1 torr
WITH OXYGEN WITH R134a FREON
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 17: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/17.jpg)
17
Shower-head electrode
Shower-head electrode has nearly 500 holes of 0.3 mm dia. to distribute gas mixture uniformly over entire 270 mm X 270 mm area. This plate is hard anodized on front surface and also serves as RF powered electrode
View window of toughened glass to view RF plasma
Also used for Langmuir Probe /OES measurements
Slides from Alpha Pneumatics
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 18: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/18.jpg)
18
Kapton Etching parameters• Gas Pressure : 1.10 torr• For Polyamide a) R134a : 5 SCCM ( 20%) b) O2 :20 SCCM ( 80%) Achieved etch rate : 0.5 micron/Min For Copper a) R134a : 25 SCCM b) O2 : 2.5 SCCM Achieved etch rate : 0.1 micron /Min• RF Power Density : 1.03 Watt/Sq cm.• Substrate Temp : 25C ( Start), 35C (End)• Duration : 10 .0 minL. M. Pant Industralisation of GEM Foils,
RD51 miniweek, CERN, 06 Feb 2014
![Page 19: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/19.jpg)
Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
19
SEM photograph of plasma etched silicon grooves with large aspect (L / a) ratio
L = 20 m
a = 2 m
Slides from Alpha Pneumatics
L. M. Pant
![Page 20: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/20.jpg)
20
Etching of Kapton Foil
Covered strips
Etched Steps
Copper finger
10 m depth8 mm width
Slides from Alpha Pneumatics
L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
![Page 21: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/21.jpg)
21L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
Summary and Outlook - 1
• ToT exists between Micropack and CERN
• ToT exists between KIED and CERN
• Alpha Pneumatics plans to visit CERN in Summer 2014
![Page 22: L. M. Pant, A. K. Mohanty Nuclear Physics Division Bhabha Atomic Research Centre, Mumbai](https://reader030.vdocument.in/reader030/viewer/2022033016/568163b0550346895dd4c7db/html5/thumbnails/22.jpg)
22L. M. Pant Industralisation of GEM Foils, RD51 miniweek, CERN, 06 Feb 2014
Summary and Outlook – 2 : A GEM Collaboration
CERN Indian Institutes
Indian Industries
BARCDUNISERPUSINP