S.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated or measured / Quantity Measured / Instrument Measurement range and additional parameters where applicable(Range and Frequency) Calibration and Measurement Capability(CMC)(±) Calibration or Measurement Method or procedure) Permanent Facility 1 ELECTRO- TECHNICAL- ALTERNATING CURRENT (< 1 GHZ) (Measure) Capacitance (1 kHz) 1 nF to 100 nF 0.056% to 0.061% Direct Method using LCR Meter 2 ELECTRO- TECHNICAL- ALTERNATING CURRENT (< 1 GHZ) (Measure) Capacitance (1 kHz) 100 nF to 1 µF 0.05% Direct Method using LCR Meter 3 ELECTRO- TECHNICAL- ALTERNATING CURRENT (< 1 GHZ) (Measure) Capacitance (1kHz) 1 µF to 100 µF 0.05% Direct Method using LCR Meter 4 ELECTRO- TECHNICAL- ALTERNATING CURRENT (< 1 GHZ) (Measure) Current (300 Hz to 10 kHz) 1 A to 20 A 0.079% to 0.102% Direct Method with using master 8½ DMM Fluke 8508 A 5 ELECTRO- TECHNICAL- ALTERNATING CURRENT (< 1 GHZ) (Measure) Current (300 Hz to 10 kHz) 100 µA to 100 mA 0.03% Direct Method using master 8½ DMM Fluke 8508 A This is annexure to 'Certificate of Accreditation' and does not require any signature. Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RD CROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA Accreditation Standard ISO/IEC 17025:2017 Certificate Number CC-2473 Page No. : 1 / 90 Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Upload: others

Post on 10-Aug-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

Permanent Facility

1 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1 kHz) 1 nF to 100 nF 0.056% to 0.061% Direct Method usingLCR Meter

2 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1 kHz) 100 nF to 1 µF 0.05% Direct Method usingLCR Meter

3 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1kHz) 1 µF to 100 µF 0.05% Direct Method usingLCR Meter

4 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

1 A to 20 A 0.079% to 0.102% Direct Method withusing master 8½ DMMFluke 8508 A

5 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

100 µA to 100 mA 0.03% Direct Method usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 1 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 2: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

6 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

100 mA to 1 A 0.041% to 0.079% Direct Method usingmaster 8½ DMM Fluke8508 A

7 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (50 Hz) 20 A to 1000 A 0.5% to 1.0% Direct method masterUsing Shunt With DMM

8 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Inductance (1kHz) 100 µH to 100 mH 0.236% to 0.065% Direct Method usingmaster LCR meter

9 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Inductance (1kHz) 100 mH to 10 H 0.065% to 0.073% Direct Method usingLCR Meter

10 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

1 mV to 100 mV 0.820% to 0.014% Direct method usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 2 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 3: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

11 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

1 V to 100 V 0.017% to 0.011% Direct Method usingmaster 8½ DMM Fluke8508A

12 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

100 mV to 1 V 0.014% to 0.017% Direct method usingmaster 8½ DMM Fluke8508A

13 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (45 Hz to 1kHz)

100 V to 1000 V 0.01% to 0.007% Direct Method usingmaster 8½ DMM Fluke8508 A

14 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (50 kHz to 500kHz)

1 V to 20 V 0.07% to 0.230% Direct Method usingmaster 8½ DMM Fluke8508 A

15 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance (1 kHz) 220 pF to 300 nF 5.79% to 0.27% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 3 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 4: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

16 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance (100 Hz) 1 µF to 30 µF 1.55% to 0.56% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

17 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance(1 kHz) 300 nF to 100 µF 0.27% to 1.13% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

18 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 3.3 mA to 1 A 0.15% to 0.073% Direct Method by usingmaster StandardCalibrator Fluke 5522A

19 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 30 µA to 330 µA 0.54% to 0.17% Direct Method by usingmaster StandardCalibrator Fluke 5522A

20 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 330 µA to 3.3 mA 0.17% to 0.15% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 4 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 5: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

21 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (10Hz to 1kHz) 330 µA to 3.3 mA 0.25% to 0.26% Direct Method by usingmaster StandardCalibrator Fluke 5522A

22 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (10Hz to 1kHz) 3.3 mA to 3 A 0.26% to 0.23% Direct Method by usingmaster StandardCalibrator Fluke 5522A

23 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1kHz) 1 A to 10 A 0.073% to 0.12% Direct Method by usingmaster StandardCalibrator Fluke 5522A

24 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (45 Hz to 5kHz)

3 A to 20 A 0.23% to 0.13% Direct Method by usingmaster StandardCalibrator Fluke 5522A

25 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (50 Hz) 20 A to 1000 A 0.68% to 0.37% Direct Method by usingmaster StandardCalibrator Fluke 5522A& current coil

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 5 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 6: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

26 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Inductance (1 kHz) 100 µH to 10 H 2.35 % to 1.14 % Direct Method usingmaster DecadeInductance Box

27 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50 Hz @ UPF 1.2 W to4.8 kW,0.01 A to 20A,120 V to 240 V

0.16% Direct Method usingmaster StandardCalibrator Fluke 5522A

28 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @ 0.5 Lag, 6 W

to 2.4 kW,0.01 A to20 A,120 V to240 V

0.46% Direct Method usingmaster StandardCalibrator Fluke 5522A

29 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @ 0.8 Lead 9.6W to 3.8 kW,0.01 A to20 A,120 V to 240 V

0.20% Direct Method usingmaster StandardCalibrator Fluke 5522A

30 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @0.2 Lag, 2.4 W

to 960 W,0.01 A to20 A,120 V to240 V

0.56% Direct Method usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 6 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 7: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

31 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power Factor 0.2 Lag to UPF 0.003 Direct Method usingmaster StandardCalibrator Fluke 5522A

32 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power Factor 0.2 Lead to UPF 0.0003 Direct Method usingmaster StandardCalibrator Fluke 5522A

33 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

1 V to 30 V 0.080% to 0.042% Direct Method by usingmaster StandardCalibrator Fluke 5522A

34 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

100 mV to 1 V 0.086% to 0.080% Direct Method by usingmaster StandardCalibrator Fluke 5522A

35 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

30 mV to 100 mV 0.12% to 0.086% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 7 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 8: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

36 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (100kHz) 30 mV to 30 V 0.452% to 0.054% Direct Method by usingmaster StandardCalibrator Fluke 5522A

37 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (100kHz) 30 V to 100 V 0.054% to 0.024% Direct Method by usingmaster StandardCalibrator Fluke 5522A

38 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45 Hz to 1kHz)

30 V to 300 V 0.20% to 0.022% Direct Method by usingmaster StandardCalibrator Fluke 5522A

39 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45 Hz to 1kHz)

300 V to 1000 V 0.022% to 0.035% Direct Method by usingmaster StandardCalibrator Fluke 5522A

40 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (450kHz) 30 mV to 3 V 1.116% to 0.121% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 8 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 9: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

41 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45Hz to10kHz)

1 mV to 3 mV 0.712% to 0.24% Direct Method by usingmaster StandardCalibrator Fluke 5522A

42 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45Hz to10kHz)

3 mV to 30 mV 0.24% to 0.042% Direct Method by usingmaster StandardCalibrator Fluke 5522A

43 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 1 A to 20 A 0.080% to 0.052% Direct method by usingmaster 8½ DMM Fluke8508 A

44 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 1 mA to 100 mA 0.002% to 0.008% Direct method by usingmaster 8½ DMM Fluke8508 A

45 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 10 µA to 100 µA 0.0010% Direct method by usingmaster 8½ DMM Fluke8508 A

46 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 100 µA to 1 mA 0.001% to 0.002% Direct method by usingmaster 8½ DMM Fluke8508 A

47 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 100 mA to 1 A 0.062% to 0.080% Direct method by usingmaster 8½ DMM Fluke8508 A

48 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 20 A to 1000 A 1.19% Direct Method using8½ DMM Fluke 8508with Shunt

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 9 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 10: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

49 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 Gohm to 10 Gohm 0.116% to 0.133% Direct Method by Usingmaster 8½ DMM Fluke8508 A

50 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 Mohm to 10 Mohm 0.001% to 0.002% Direct Method by Usingmaster 8½ DMM Fluke8508 A

51 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 mohm to 100 mohm 0.061% to 0.207% Direct Method by Usingmaster LCR Meter &DRB

52 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 ohm to 100 ohm 0.0015% to 0.0010% Using LCR Meter &DRB

53 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 10 kohm to 100 kohm 0.0007% to 0.0008% Direct Method by Usingmaster 8½ DMM Fluke8508 A

54 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 10 Mohm to 100 Mohm 0.002% to 0.008% Direct method by usingmaster 8½ DMM Fluke8508 A

55 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 Mohm to 1 Gohm 0.008% to 0.116% Direct Method by Usingmaster 8½ DMM Fluke8508 A

56 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 mohm to 150mohm

0.206% Direct Method by Usingmaster LCR Meter &DRB

57 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 ohm to 10 kohm 0.0010% to 0.0007% Direct Method by Usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 10 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 11: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

58 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 kohm to 1 Mohm 0.0008% to 0.001% Direct Method by Usingmaster 8½ DMM Fluke8508 A

59 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 150 mohm to 1 ohm 0.206% to 0.0015% Direct Method by usingmaste LCR Meter &DRB

60 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 1 mV to 100 mV 0.44% to 0.0003% Direct Method by usingmaster StandardCalibrator Fluke 5522A

61 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 1 V to 100 V 0.0002% to 0.0003% Direct Method by usingmaster DMM Fluke8508A

62 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 100 mV to 1 V 0.0003% to 0.0003% Direct Method by usingmaster StandardCalibrator Fluke 5522A

63 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 100 V to 1000 V 0.0004% to 0.0004% Direct Method by usingmaster StandardCalibrator Fluke 5522A

64 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 1 A to 10 A 0.027% to 0.063% Direct Method by usingmaster StandardCalibrator Fluke 5522A

65 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 1 mA to 100 mA 0.016% to 0.011% Direct Method by usingmaster StandardCalibrator Fluke 5522A

66 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 10 µA to 100 µA 0.25% to 0.023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 11 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 12: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

67 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 10 A to 20 A 0.063% to 0.11% Direct Method by usingmaster StandardCalibrator Fluke 5522A

68 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 100 µA to 1 mA 0.023% to 0.016% Direct Method by usingmaster StandardCalibrator Fluke 5522A

69 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 100 mA to 1 A 0.011% to 0.027% Direct Method by usingmaster StandardCalibrator Fluke 5522A

70 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 20 A to 200 A 0.5% Direct Method usingCurrent Source

71 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 200 A to 1000 A 0.66% to 0.32% Direct Method by usingmaster Fluke 5522Awith current coil 5500A

72 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Power 10 W to 1 kW,1V to1000V, 1mA to 1000A.

0.08% to 0.45% Using Calibrator Fluke5522A with CurrentCoil Direct Method.

73 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Power (1V to1000V, 1mA to 1000A)

1 KW to 19.9 KW 0.45% to 0.65% Using Calibrator Fluke5522A with current coilDirect Method.

74 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Oscilloscope 1 mV to 130 V 0.29% to 0.096% Direct Method

75 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 0.1 Mohm to 1 Gohm 5.89% to 4.91% Direct Method usingmaster of high stabilityDecade Megohm Box

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 12 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 13: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

76 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 Gohm to 100 Gohm 4.91% to 8.61% Direct Method usingmaster of high stabilityDecade Megohm Box

77 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 kohm to 10 kohm 0.0036% to 0.0035% Direct Method usingStandard CalibratorFluke 5522A

78 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 mohm 0.609% Direct Method usingfixed resistor box

79 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 Mohm to 10 Mohm 0.0041% to 0.014% Direct Method usingStandard CalibratorFluke 5522A

80 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 ohm to 10 ohm 0.10% to 0.015% Direct Method usingStandard CalibratorFluke 5522A

81 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 kohm to 100 kohm 0.0035% to 0.0034% Direct Method usingStandard CalibratorFluke 5522A

82 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 mohm 0.610% Direct Method usingfixed resistor box

83 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 Mohm to 300 Mohm 0.014% to 0.38% Direct Method usingStandard CalibratorFluke 5522A

84 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 ohm to 100 ohm 0.015% to 0.004% Direct Method usingStandard CalibratorFluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 13 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 14: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

85 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 Gohm to 1 Tohm 5.81% Direct Method usingmaster of high stabilityDecade Megohm Box

86 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 ohm to 1 kohm 0.004% to 0.0036% Direct Method usingStandard CalibratorFluke 5522A

87 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 kohm to 1 Mohm 0.0034% to 0.0041% Direct Method usingStandard CalibratorFluke 5522A

88 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 150 mohm 0.609% Direct Method usingfixed resistor box

89 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 150 mohm to 1 ohm 0.611% to 0.10% Direct Method usingStandard CalibratorFluke 5522A:

90 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 300 Mohm to 1 Gohm 0.38% to 1.78% Direct Method usingStandard CalibratorFluke 5522A

91 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 50 mohm 0.610% Direct Method usingsing fixed resistor box

92 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 1 mV to 10 mV 0.240% to 0.023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

93 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 1 V to 10 V 0.0015% to 0.0016% Direct Method usingmaster StandardCalibrator Fluke 5522A:

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 14 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 15: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

94 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 10 mV to 100 mV 0.023% to 0.0039% Direct Method by usingmaster StandardCalibrator Fluke 5522A

95 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 10 V to 1000 V 0.0016% to 0.0023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

96 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 100 mV to 1 V 0.0039% to 0.0015% Direct Method by usingmaster StandardCalibrator Fluke 5522A

97 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Amplitude-Sq wave /Oscilloscope (1 kHz)

1 mV to 55 Vp-p 0.6% to 0.3% Direct Method by usingmaster StandardCalibrator Fluke 5522A

98 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Bandwidth -Oscilloscope

50 kHz to 1 GHz 0.23% to 0.87% Direct Method usingmaster StandardCalibrator Fluke 5522A

99 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(B type)

600 °C to 1750 °C

0.53°C to 0.39°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

100 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(E type)

-200 °C to 900 °C 0.48°C to 0.27°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 15 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 16: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

101 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller (Jtype)

-200 °C to 1200 °C 0.28°C to 0.31°C Direct Method by usingMaster used- StndCalibrator Fluke 5522A& 6½ DMM

102 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(K type)

-200 °C to 1350 °C 0.26°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

103 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(N type)

-200 °C to 1300 °C 0.48°C to 0.35°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

104 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(R type)

10 °C to 1750 °C 0.67°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A

105 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(RTD type)

-200 °C to 800 °C 0.05 °C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 16 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 17: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

106 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(S type)

10 °C to 1450 °C 0.56°C to 0.54°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

107 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller (Ttype)

-200 °C to 400 °C 0.60°C to 0.17°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

108 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(B type)

600 °C to 1750 °C 0.47°C to 0.11°C Direct Method by usingMaster StandardCalibrator fluke 5522A

109 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(E type)

-200 °C to 900 °C 0.20°C to 0.45°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

110 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller (Jtype)

-200 °C to 1200 °C 0.15°C to 0.25°C Direct Method by usingMaster StandardCalibrator fluke 5522A

111 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(K type)

-200 °C to 1350 °C 0.37°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 17 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 18: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

112 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(N Type )

-200 °C to 1300 °C 0.45°C to 0.30°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

113 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(R type)

10 °C to 1750 °C 0.62°C to 0.44°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

114 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(RTD type)

-200 °C to 800 °C 0.071°C to 0.083°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

115 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(S type)

10 °C to 1750 °C 0.61°C to 0.51°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

116 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller (Ttype)

-200 °C to 400 °C 0.55°C to 0.16°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

117 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Frequency 10 Hz to 1 GHz 0.0011% to 0.0024% Direct Method usingmaster FrequencyCounter Philips- PM6669

118 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 1 sec to 9000 sec 0.06% to 0.05% Comparison Method byusing master DigitalTimer Beltronics - 501

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 18 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 19: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

119 ELECTRO-TECHNICAL- TIME &FREQUENCY (Source)

Frequency 1 Hz to 1 GHz 0.004% to 0.006% Direct Method usingmaster StandardCalibrator Fluke 5522A

120 ELECTRO-TECHNICAL- TIME &FREQUENCY (Source)

Timer Marker /Oscilloscope

1 ns to 5 s 0.0003 sec Direct Method usingmaster StandardCalibrator Fluke 5522A

121 MECHANICAL-ACCELERATION ANDSPEED

Acceleration (Peak)@80Hz

6.6 m/s2 2.96% Using Digital VibrationMeter by ComparisonMethod

122 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@160Hz

10.0 m/s2 2.83% Using Digital VibrationMeter by ComparisonMethod

123 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@160Hz

20.1 m/s2 2.48 % Using Digital VibrationMeter by ComparisonMethod

124 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@160Hz

40.2 m/s2 2.44 % Using Digital VibrationMeter by ComparisonMethod

125 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@160Hz

50.1 m/s2 2.41 % Using Digital VibrationMeter by ComparisonMethod

126 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@40Hz

12.3 m/s2 2.56 % Using Digital VibrationMeter by ComparisonMethod

127 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@40Hz

20.5 m/s2 2.49 % Using Digital VibrationMeter by ComparisonMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 19 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 20: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

128 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@40Hz

28.8 m/s2 2.49 % Using Digital VibrationMeter by ComparisonMethod

129 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@40Hz

4.0 m/s2 3.43 % Using Digital vibrationMeter By ComparisonMethod

130 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@80Hz

11.5 m/s2 2.63 % Using Digital VibrationMeter by ComparisonMethod

131 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@80Hz

16.7 m/s2 2.53 % Using Digital VibrationMeter by ComparisonMethod

132 MECHANICAL-ACCELERATION ANDSPEED

Acceleration(Peak)@80Hz

2.8 m/s2 5.04 % Using Digital VibrationMeter by ComparisonMethod

133 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@160Hz

0.009 mm 11.87% Using Digital VibrationMeter by ComparisonMethod

134 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@160Hz

0.030 mm 4.36% Using Digital VibrationMeter by ComparisonMethod

135 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@160Hz

0.050 mm 3.24% Using Digital VibrationMeter by ComparisonMethod

136 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@160Hz

0.126 mm 2.56% Using Digital VibrationMeter by ComparisonMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 20 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 21: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

137 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@40Hz

0.065 mm 2.89% Using Digital VibrationMeter by ComparisonMethod

138 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@40Hz

0.196 mm 2.47% Using Digital VibrationMeter by ComparisonMethod

139 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@40Hz

0.263 mm 2.45% Using Digital VibrationMeter by ComparisonMethod

140 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@40Hz

0.459 mm 2.44% Using Digital VibrationMeter by ComparisonMethod

141 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@80 Hz

0.026 mm 4.79% Using Digital VibrationMeter by ComparisonMethod

142 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@80Hz

0.011 mm 10.27% Using Digital VibrationMeter by ComparisonMethod

143 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@80Hz

0.046 mm 3.08% Using Digital VibrationMeter by ComparisonMethod

144 MECHANICAL-ACCELERATION ANDSPEED

Displacement(Peak)@80Hz

0.067 mm 2.76% Using Digital VibrationMeter by ComparisonMethod

145 MECHANICAL-ACCELERATION ANDSPEED

Stroboscope,tachometer (NonContact Type)

25000 rpm to 45000rpm

0.008% By Comparison methodby using masterTachometer Calibrator

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 21 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 22: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

146 MECHANICAL-ACCELERATION ANDSPEED

Stroboscope,tachometer (NonContact Type)

60 rpm to 25000 rpm 0.7% to 0.008% By Comparison methodby using masterTachometer Calibrator

147 MECHANICAL-ACCELERATION ANDSPEED

Tachometer ( ContactType)

100 rpm to 5000 rpm 1.4% to 0.12% Comparison Method byusing masterTachometer Calibration

148 MECHANICAL-ACCELERATION ANDSPEED

Velocity (Peak) @40Hz 82.0 mm/s 2.42% Using Digital VibrationMeter by ComparisonMethod

149 MECHANICAL-ACCELERATION ANDSPEED

Velocity (Peak)mm/s@40Hz

16.1 mm/s 2.52% Using Digital VibrationMeter by ComparisonMethod

150 MECHANICAL-ACCELERATION ANDSPEED

Velocity (Peak)@40Hz 48.7 mm/s 2.43% Using Digital VibrationMeter by ComparisonMethod

151 MECHANICAL-ACCELERATION ANDSPEED

Velocity (Peak)@40Hz 65.1 mm/s 2.42% Using Digital VibrationMeter by ComparisonMethod

152 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@160Hz 39.9 mm/s 2.42% Using Digital VibrationMeter by ComparisonMethod

153 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@160Hz 69.7 mm/s 2.41% Using Digital VibrationMeter by ComparisonMethod

154 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@160Hz 9.9 mm/s 2.80% Using Digital VibrationMeter by ComparisonMethod

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 22 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 23: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

155 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@160Hz 99.3 mm/s 2.41% Using Digital VibrationMeter by ComparisonMethod

156 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@80Hz 13.2 mm/s 2.50% Using Digital VibrationMeter by ComparisonMethod

157 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@80Hz 22.8 mm/s 2.47% Using Digital VibrationMeter by ComparisonMethod

158 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@80Hz 33.3 mm/s 2.44% Using Digital VibrationMeter by ComparisonMethod

159 MECHANICAL-ACCELERATION ANDSPEED

Velocity(Peak)@80Hz 5.7 mm/s 3.00% Using Digital VibrationMeter by ComparisonMethod

160 MECHANICAL-ACOUSTICS

Sound Level Meter 114 dB @ 1kHz 0.82dB Using Sound levelCalibrator

161 MECHANICAL-ACOUSTICS

Sound Level Meter 94 dB @ 1kHz 0.82dB Using Sound levelCalibrator

162 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

3 Point Micrometer,Res : 0.001 mm

0 to 100 mm 3.6µm Using master MasterRing Gauges

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 23 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 24: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

163 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Bevel Protractor, Res:1min

0 ° to 360 °

5.66arc of min Using profile projector

164 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Bore Gauge (0.001mm) Upto 2mmTransmisson only

2.4µm Using masterElectronic Dial gaugecalibration Tester

165 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper (Analog / Dial /Digital) Res: 0.01mm

0 mm to 1000 mm 8.6µm Using master CaliperChecker & GaugeBlock

166 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Caliper Checker 0 mm to 1000 mm 8µm Using master GaugeBlock Set & HeightMeasuring System

167 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Coating ThicknessGauge (Res: 0.1 µm)

0 to 2000 µm 3.4µm Using master StandardThickness Foils

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 24 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 25: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

168 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Combination Set,Res:1°

0 ° to 180 ° 13.2 arc of min Using Profile Projector

169 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Comparator Dial Stand( Flatness)

Up to 300 mm 7µm Using master Lever dial& Linear height master

170 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Depth Micrometer,Res: 0.001mm

0 mm to 300 mm 4µm Using Master GaugeBlock Set

171 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Depth Vernier ( Analog/ Dial / Digital), Res:0.01mm

0 mm to 600 mm 15.2µm Using master Gaugeblock Set

172 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Calibration Tester /LVDT probe withIndicator, Res:0.001µm

0 to 25mm 1.3µm Using master ULM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 25 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 26: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

173 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Gauge- Plungertype ( Analog / Digital),Res: 0.001mm

0 mm to 1 mm 2.3µm Using masterElectronic Dial GaugeCalibration Tester

174 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Gauge- Plungertype ( Analog / Digital),Res: 0.001mm

0 mm to 10 mm 2.6µm Using masterElectronic Dial gaugeCalibration Tester

175 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Gauge- Plungertype ( Analog / Digital),Res: 0.001mm

0 mm to 50 mm 6.3µm Using masterElectronic DialCalibration GaugeTester

176 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Dial Thickness Gauge,Res: 0.01 mm

Upto 10mm 7µm Using master GaugeBlock Set

177 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Elongation gauge 14.7 mm to 81 mm 24µm Using Digital Caliper byComparison Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 26 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 27: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

178 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Engineering Square /Angle Plates(Squareness)

Up to 350 mm 7.0µm Using master DigitalDial Gauge & LinearHeight Master

179 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

External Micrometer(Analog / Digital /Flange / Point / V Anvil/ Pitch ) , Res : 0.001mm

0 mm to 450 mm 3µm Using master GaugeBlock Set

180 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

External Micrometer(Analog / Digital /Flange / Point / V Anvil/ Pitch ) , Res : 0.01mm

0 mm to 1000 mm 7µm Using master GaugeBlock Set

181 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Feeler gauge 0.02 mm to 1 mm 2.1µm Using master UniversalLength Machine

182 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Flankiness Gauge 4.89 mm to 33.9 mm 7µm Using Profile ProjectorBy Comparison Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 27 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 28: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

183 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Foils Upto 2000 µm 1.2µm Using master UniversalLength Machine

184 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Gauge Block Set 0.5 mm to 25 mm 0.12 µm Using master GaugeBlock Grade 'k'comparator system

185 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Gauge Block Set 25 mm to 50 mm 0.12µm Using master GaugeBlock Grade 'k'

186 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Gauge Block Set 50 mm to 75 mm 0.14µm Using master GaugeBlock Grade 'k'

187 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Gauge Block Set 75 mm to 100 mm 0.20µm Using master GaugeBlock Grade 'k'

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 28 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 29: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

188 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Granite Square(Squareness, Flatness)

Upto 600 mm 13.5µm Using Lever DialGauge and Linearheight Master

189 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Groove Dial / LegCaliper (OD & ID)Gauge, Res: 0.025mm

Upto 150 mm 7.0µm Using master GaugeBlock Set

190 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Height Gauge ( Dial /Digital & Analog ) Res:0.01mm

0 mm to 1000 mm 11.8µm Using master CaliperChecker

191 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Height Gauge ( Dial /Digital & Analog ) Res:0.01mm

0 mm to 600 mm 11.2µm Using master CaliperChecker

192 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Height MeasuringSystem, Res: 0.1 µm

0 mm to 1000 mm 4.6µm By using Master GaugeBLock long Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 29 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 30: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

193 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Internal Micrometer /Stick Micrometer(Including ExtensionRod ) Res: 0.01mm

Upto 300 mm 8µm Using Gauge Block Set& gauge BlockAccessories

194 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Lever Dial Gauge(0.001mm)

0 to 0.14 mm 2.4µm Using masterElectronic Dial gaugeCalibration Tester

195 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Lever Dial Gauge(0.002mm)

0 to 0.2 mm 3.1µm Using masterElectronic Dial gaugeCalibration Tester

196 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Lever Dial Gauge, 0.01mm

0 to 1 mm 5.3µm Using masterElectronic Dial gaugecalibration Tester

197 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Measuring Pins (Grade 1& 2)

Upto 25 mm 2µm Using Universal lengthMachine

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 30 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 31: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

198 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Measuring Tape / PiTape, Res: 0.5 mm1.00 mm lc

Upto 50000 mm (541 + L/100)µm(L inmm)

Using master Scale &Tape CalibrationMachine

199 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Micrometer Head, Res: 0.001mm

Up to 25 mm 1.3µm Using Master LeverDial Gauge & LinearHeight Master

200 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Parallel Block Up to 1000 mm 10µm Using master LeverDial Gauge

201 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Pistol Caliper (Res:0.01 mm)

0 to 100 mm 10µm Using master GaugeBlock Set

202 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Pitch Micrometer, Res :0.01mm

0 to 200 mm 7µm Using master GaugeBlock Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 31 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 32: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

203 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Plain Plug Gauges 1 mm to 300 mm 1.5µm Using master UniversalLength Machine

204 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Plain Ring Gauges 4 mm to 300 mm 2.3µm Using master UniversalLength Machine

205 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Portable Roughnesstester Ra/ Rz

Up to 100 µm 6.41 µm Using SurfaceRoughness MasterBlock

206 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Radius Gauges 0.5 mm to 25.0 mm 6µm Using master Profileprojector

207 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Setting Rods &Extensions Rods

25 mm to 975 mm 10µm Using master GaugeBlock Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 32 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 33: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

208 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Snap Gauges / DialSnap Gauges / WidthGauges

10 mm to 300 mm 2.5 µm Using Universal LengthMachine

209 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Spirit Level / FrameLevel, Res : 10µm / m

Upto 0.12 mm/m 15µm/m Using masterElectronic Level

210 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Steel scale / Taperscale Res: 0.5 / 1 mm

0 mm to 1000 mm 271µm Using master scale &Tape CalibrationMachine

211 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Straight Edge 0 mm to 1000 mm 13.5µm Using Linear HeightMaster and lever DialGauge

212 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Tape Scale Calibrator 0 mm to 1000 mm 10.2µm Using Slip Gauge Setand Long Slip Gauges

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 33 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 34: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

213 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Taper Thread PlugGauge ( Effective Dia)

0 mm to 100 mm 3µm Using master UniversalLength machine

214 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Taper Thread RingGauge ( Effective Dia)

0 mm to 110 mm 4.8µm Using master UniversalLength Machine

215 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Test Sieves 0.16 mm to 1 mm 5µm Using master profileprojector

216 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Test Sieves 1 mm to 100 mm 18µm Using master profileprojector

217 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread Pitch Gauge,Set Pitch Flank Angle

0.3 mm to 6.0 mm 3 µm & 5.1 arc min Using master ProfileProjector

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 34 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 35: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

218 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread Pitch Gauge,Set Pitch Flank Angle

55 ° to 60 ° 5.1 min of arc Using master ProfileProjector

219 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread plug Gauge (Effective Dia)

Up to 300 mm 2.1µm Using master UniversalLength Machine

220 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Thread Ring Gauge (Effective Dia)

3 mm to 300 mm 2µm Using master UniversalLength Machine

221 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Ultra Sonic ThicknessGauge

Upto 200mm 7.3µm Using master GaugeBlock Set

222 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Universal LengthMeasuring Machine

Upto 100 mm 0.7µm Using master GaugeBlock Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 35 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 36: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

223 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

'V' - Block (Parallelism)symmetry, squareness

Up to 200 mm 6.6µm Using master Mandrel& Lever Dial Gauge &Linear Height Master

224 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Weld Fillet Gauge 0 mm to 25 mm 10.1µm for linear & 3min arc

Using Profile projectorBy Comparsion Method

225 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

wet / Dry FilmApplicator

0 mm to 200 mm 8.68µm Using Profile ProjectorBy ComparisionMethod

226 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Wire gauge 0.3 mm to 10 mm 8.8 µm Using Profile ProjectorBy ComparisionMethod.

227 MECHANICAL-FORCE PROVINGINSTRUMENTS

Push Pull Gauge ,Force gauge, SpringBalance

10 N to 1000 N 1.4N Using master StainLess Weights andhanger of weights 10,50, 100 N as per VDI /VDE 2624 Part 2.1

228 MECHANICAL-HARDNESS TESTINGMACHINES

Shore Hardness Tester 0 to 100 Shore A&D 2.2 Shore A&D Using RubberHardness TesterASTM-D-2240-15

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 36 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 37: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

229 MECHANICAL-PRESSUREINDICATING DEVICES

Digital / Dial VaccumGauges / Transmitters /Transducers.

0 bar to (-) 0.75 bar 0.014 bar Digital Pressure Gaugewith uncertainty of0.0008 bar. Procedurebased on ISO 3567 &ISO 27893 standards.

230 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(HYDRAULIC)Digital /Analog PressureGauges, PressureIndicator WithTransducer /Transmitter, PressureSwitch

0 bar to 1000 bar 0.15 bar Digital Pressure gaugewith uncertainty of0.021 bar. Procedurebased on DKD-R 6-1guidelines.

231 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(HYDRAULIC)Digital /Analog PressureGauges, PressureIndicator WithTransducer /Transmitter & PressureSwitches

0 bar to 700 bar 0.29 bar Digital Pressure gaugewith uncertainty of0.182 bar. Procedurebased on DKD-R 6-1guidelines.

232 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC) Digital /Dial Gauges / PressureIndicator WithTransmitter /Transducer.

0 bar to 20 bar 0.014 bar Digital Pressure gaugewith uncertainty of0,01bar. Procedurebased on DKD-R 6-1guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 37 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 38: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

233 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Pressure gauges,Magnehelic gauges,Differential PressureTransmitters, LowPressure Indicators/Transducers,Barometer

0 mbar to 500 mbar 0.31 mbar Digital Manometer withuncertainty of 0.06mbar. Procedure basedon DKD-R 6-1guidelines.

234 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Digital /Dial Gauges / PressureIndicator WithTransmitter /Transducer.

0 bar to 70 bar 0.04 bar Digital Pressure gaugewith uncertainty of0.022 bar. Procedurebased on DKD-R 6-1guidelines.

235 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Pressure gauges, Magnehelicgauges, DifferentialPressure Transmitters,Low PressureIndicators/Transducers,Barometer.

0 mbar to 2000 mbar 2.14 mbar Digital Manometer withuncertainty of 1.03mbar. Procedure basedon DKD-R 6-1guidelines.

236 MECHANICAL-TORQUEMEASURINGDEVICES

Torque Wrench (Type-I)Class B,C,D,E andType II class A B C D

200 Nm to 1000 Nm 1.2 % Using Torque wrenchCalibration System asper IS/ISO 6789

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 38 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 39: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

237 MECHANICAL-TORQUEMEASURINGDEVICES

Torque Wrench (Type-I)Class B,C,D,E, TypeII, A B C D

0 Nm to 20 Nm 0.36 % Using Torque wrenchCalibration System asper IS/ISO 6789

238 MECHANICAL-TORQUEMEASURINGDEVICES

Torque Wrench (Type-I)Class B,C,D,E, TypeII, Class A, B, C, D

20 Nm to 200 Nm 1.5% Using Torque wrenchCalibration System asper IS/ISO 6789,

239 MECHANICAL- UTM,TENSION CREEPAND TORSIONTESTING MACHINE

Universal TestingMachine (CompressionMode)

100 N to 1000 KN 0.80% Using master ProvingRing and load cells asper IS 1828 Part 12015

240 MECHANICAL- UTM,TENSION CREEPAND TORSIONTESTING MACHINE

Universal TestingMachine (CompressionMode)

200 kN to 2000 KN 0.80 % Using master ProvingRing and load cells asper IS 1828 Part 12015

241 MECHANICAL- UTM,TENSION CREEPAND TORSIONTESTING MACHINE

Universal TestingMachine (TensileMode)

0.5 KN to 50 KN 0.99% Using master LoadCells as per IS 1828Part 1 2015

242 MECHANICAL-VOLUME

DENSITYHydrometer ,L.C= 0.0005 g/ ml

0.600 g / ml to 1.8 g/ ml 0.0009 g/ml using referencehydrometer andcalibration liquid ofappropriate density.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 39 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 40: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

243 MECHANICAL-VOLUME

Measuring Cylinder 10 ml 0.8 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

244 MECHANICAL-VOLUME

Measuring Cylinder 100 ml 1.9 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.001 g)

245 MECHANICAL-VOLUME

Measuring Cylinder 1000 ml 11.5 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.001g)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 40 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 41: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

246 MECHANICAL-VOLUME

Measuring Cylinder 10000 ml 75.0 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 g)

247 MECHANICAL-VOLUME

Measuring Cylinder 20 ml 1.5 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

248 MECHANICAL-VOLUME

Measuring Cylinder 200 ml 2.3 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.001 g)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 41 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 42: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

249 MECHANICAL-VOLUME

Measuring Cylinder 2000 ml 12.0 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01g)

250 MECHANICAL-VOLUME

Measuring Cylinder 5 ml 0.1 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

251 MECHANICAL-VOLUME

Measuring Cylinder 50 ml 1.5 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 42 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 43: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

252 MECHANICAL-VOLUME

Measuring Cylinder 500 ml 10.5 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodbased on ISO4787:2010 & ISO20461 with Electronicweighing Balance (Readability : 1 mg)

253 MECHANICAL-VOLUME

Measuring Cylinder 5000 ml 25.0 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 g)

254 MECHANICAL-VOLUME

Micropipette 1 µl 0.01 µl Using Weights ofAccuracy Class E1 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 43 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 44: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

255 MECHANICAL-VOLUME

Micropipette 10 µl 0.03 µl Using Weights ofAccuracy Class E1 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

256 MECHANICAL-VOLUME

Micropipette 100 µl 0.62 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

257 MECHANICAL-VOLUME

Micropipette 1000 µl 6.20 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.01 mg )

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 44 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 45: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

258 MECHANICAL-VOLUME

Micropipette 2 µl 0.01µl Using Weights ofAccuracy Class E1 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

259 MECHANICAL-VOLUME

Micropipette 20 µl 0.04 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.01 mg /0.1 mg)

260 MECHANICAL-VOLUME

Micropipette 200 µl 1.30 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 45 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 46: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

261 MECHANICAL-VOLUME

Micropipette 2000 µl 12.5 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.01 mg /0.1 mg)

262 MECHANICAL-VOLUME

Micropipette 5 µl 0.02 µl Using Weights ofAccuracy Class E1 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

263 MECHANICAL-VOLUME

Micropipette 50 µl 0.20 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.001 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 46 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 47: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

264 MECHANICAL-VOLUME

Micropipette 500 µl 3.10 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.01 mg )

265 MECHANICAL-VOLUME

Micropipette 5000 µl 32.0 µl Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 8655( part 6):2002 with using masterMicro Balance (Readability : 0.1 mg)

266 MECHANICAL-VOLUME

Pipette & burette 10 ml 0.03 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 47 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 48: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

267 MECHANICAL-VOLUME

Pipette & burette 100 ml 0.21 mlml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

268 MECHANICAL-VOLUME

Pipette & burette 25 ml 0.06ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg )

269 MECHANICAL-VOLUME

Pipette & burette 5 ml 0.02 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 48 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 49: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

270 MECHANICAL-VOLUME

Pipette & burette 50 ml 0.11 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

271 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

10 ml 0.03ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg)

272 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

100 ml 0.21 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 49 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 50: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

273 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

1000 ml 2.2 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 g)

274 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

20 ml 0.06 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg)

275 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

200 ml 0.41 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.001 g)

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 50 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 51: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

276 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

2000 ml 4.60 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 g)

277 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

5 ml 0.02 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.01 mg )

278 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

50 ml 0.11 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.1 mg )

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 51 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 52: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

279 MECHANICAL-VOLUME

Volumetric ( Flask /Beaker)

500 ml 1.03 ml Using Weights ofAccuracy Class E2 &Distilled water byGravimetric methodson ISO 4787:2010 &ISO 20461 with masterusing Balance (Readability : 0.001 g)

280 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.0001 mg

1 mg to 2.1 g 0.003mg Using StandardWeights of acccuracyClass E1 andprocedure based OIMLR-76: 2006.

281 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class Ii) Readability :1 mg

1 mg to 1 kg 0.002 g Using StandardWeights of accuracyClass E1 & E2, andprocedure as per OIMLR-76: 2006.

282 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 g to 20 kg 0.10 g Using StandardWeights of AccuracyClass E2 & F1.Procedure as per OIMLR-76: 2006.

283 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III)Readability :10 g

10 g to 100 kg 10.0 g Using StandardWeights of accuracyClass M1 andprocedure as per OIMLR76:2006

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 52 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 53: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

284 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCEReadability : 1 g

1 g to 100 kg 1.0 g Using StandardWeights of accuracyClass M1, andprocedure as per OIMLR76:2006.

285 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.001 mg

1 mg to 5.1 g 0.005 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

286 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.1 mg

1 mg to 200 g 0.06 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

287 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I)Readability :0.01 mg

1 mg to 50 g 0.011 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

288 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class II)Rwadability:10 mg

0.1 mg to 5 kg 0.011 g Using StandardWeights of AccuracyClass E1& E2 .Procedure as per OIMLR 76:2006.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 53 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 54: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

289 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 g to 35 kg 0.97 g Using StandardWeights of accuracyClass F1& M1.Peocedure as perOIML R-76: 2006.

290 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 mg to 10 kg 0.037 g Using StandardWeights of AccuracyClass E1& E2.Procedure as per OIMLR-76: 2006.

291 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :50 g

2 kg to 500 kg 20.0 g Using StandardWeights of accuracyClass F2. Peocedureas per OIML R76:2006

292 MECHANICAL-WEIGHING SCALEAND BALANCE

Electronic WeighingBalance (ClassIII)Readability: 100 mg

0.1 mg to 2 kg 0.011 mg Using Weights ofAccuracy Class E1&E2 . Procedure as perOIML R 76:2006.

293 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class IV)Readability :100 g

2 kg to 1000 kg 50.0 g Using StandardWeights of accuracyClass M1, procedureas per OIML R76:2006

294 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

1 g 0.004 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 54 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 55: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

295 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

1 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance (d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

296 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

10 g 0.012mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.01mg).Procedure as per OIMLR 111-1 guidelines.

297 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

10 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

298 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

2 g 0.004 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 55 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 56: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

299 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

2 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

300 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

20 g 0.016 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.01mg).Procedure as per OIMLR 111-1 guidelines.

301 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

20 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

302 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

200 g 0.099 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.01mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 56 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 57: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

303 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

200 mg 0.003 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111- 1, 2004.

304 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

5 g 0.006 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

305 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

5 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

306 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

50 g 0.014 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.01mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 57 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 58: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

307 MECHANICAL-WEIGHTS

MASS - Weights (E2Class & Coarser)

500 mg 0.003 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

308 MECHANICAL-WEIGHTS

MASS - Weights (F1Class & Coarser)

1 kg 0.001 g Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 1mg).Procedure as per OIMLR 111-1 guidelines.

309 MECHANICAL-WEIGHTS

MASS - Weights (F1Class & Coarser)

500 g 0.001 g Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 1mg).Procedure as per OIMLR 111-1 guidelines.

310 MECHANICAL-WEIGHTS

MASS - Weights (F2Class & Coarser)

2 kg 0.009 g Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 10mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 58 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 59: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

311 MECHANICAL-WEIGHTS

MASS - Weights (F2Class & Coarser)

20 kg 0.090 g Using StandardWeights of accuracyClass E2 andElectronic weighingBalance(d: 100mg).Procedure as per OIMLR 111-1 guidelines.

312 MECHANICAL-WEIGHTS

MASS - Weights (M1Class & Coarser)

10 kg 0.083 g Using StandardWeights of accuracyClass E2 andElectronic weighingBalance(d: 100mg).Procedure as per OIMLR 111-1 guidelines.

313 MECHANICAL-WEIGHTS

MASS -WEIGHTS(AccuracyClass F2 and coarser)

5 kg 10.0mg Using E2 ClassStandard Weights andElectronic weighingbalance(d: 10mg).Procedure as per OIMLR111-1.

314 MECHANICAL-WEIGHTS

MASS - Weights(E2Class & Coarser)

100 g 0.089 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.01mg).Procedure as per OIMLR 111-1 guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 59 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 60: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

315 MECHANICAL-WEIGHTS

MASS Weights (E2Class & Coarser)

50 mg 0.002 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

316 MECHANICAL-WEIGHTS

Weights (E2 Class &Coarser)

100 mg 0.003 mg Using StandardWeights of accuracyClass E1 andElectronic weighingBalance(d: 0.001mg).Procedure as per OIMLR 111-1 guidelines.

317 OPTICAL- OPTICAL Lux / Light Meter 100 lx to 10000 lx 3.5% Using Light Chamberand Lux Meter ByComparison Method

318 THERMAL- SPECIFICHEAT & HUMIDITY

Humidity (Digital &Analog Thermohygrometer)Temperature &Humidity Meter,Humidity Indicator,Humidity &TemperatureTransmitter withIndicator

20 %RH to 95 %RH@25 ºC

1.48%RH Using StandardHumidity Meter withHumidity Generator

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 60 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 61: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

319 THERMAL- SPECIFICHEAT & HUMIDITY

Humidity (Digital &Analog Thermohygrometer)Temperature &Humidity Meter,Humidity Indicator,Humidity &TemperatureTransmitter withIndicator

5 °C to 50 °C@60%RH 0.36°C Using StandardHumidity Meter withHumidity Generator

320 THERMAL-TEMPERATURE

Glass Thermometer -80 °C to 150 °C 0.72°C Using SPRT withIndicator & oil

321 THERMAL-TEMPERATURE

Indicators of Oil Baths /Low & High Temp Bath/ Dry bath / furnace /oven/ incubators /autoclave for industrialapplications - singleposition

140 °C to 600 °C 0.35°C Using SPRT & S- TypeThermocouple withdigital Indicator

322 THERMAL-TEMPERATURE

Indicators of Oil Baths /Low & High Temp Bath/ Dry bath /furnace/oven/ incubators /autoclave for industrialapplications - singleposition

-95 °C to 140 °C 0.17°C Using SPRT & S-TypeThermocouple withdigital indicator

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 61 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 62: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

323 THERMAL-TEMPERATURE

Indicators of Oil Baths /Low & High Temp Bath/ Dry bath/ furnace /oven / autoclave /incubators for industrialapplications - singleposition

600 °C to 1200 °C 2.47°C Using SPRT & S-TypeThermocouple withdigital Indicator

324 THERMAL-TEMPERATURE

Non-ContactThermometerPyrometer

50 °C to 650 °C 6.19°C Using Standard Non-Contact IR Pyrometer,Black Body (Emissivity0.950)

325 THERMAL-TEMPERATURE

Non-ContactThermometerPyrometer

650 °C to 1200 °C 7.88°C Using Standardr Non-Contact IR Pyrometer,Black Body (Emissivity0.950)

326 THERMAL-TEMPERATURE

Temperature (Digital &Analog Thermohygrometer)Temperature &Humidity Meter,Humidity Indicator,Humidity &TemperatureTransmitter withIndicator

5 °C to 50 °C 0.18 °C Using SPRT withIndicator & temperatureGenerator

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 62 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 63: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

327 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

140 °C to 600 °C 0.64°C Using SPRT withIndicator & Dry BlockBath

328 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

600 °C to 1200 °C 2.53°C Using Fluke S TypeThermocouple withIndicator & Dry BlockBath

329 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

-95 °C to 140 °C 0.18°C Using SPRT withIndicator & Dry blockBath

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 63 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 64: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

Site Facility

1 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1 kHz) 1 nF to 100 nF 0.056% to 0.061% Direct Method usingLCR Meter

2 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1 kHz) 100 nF to 1 µF 0.05% Direct Method usingLCR Meter

3 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Capacitance (1kHz) 1 µF to 100 µF 0.05% Direct Method usingLCR Meter

4 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

1 A to 20 A 0.079% to 0.102% Direct Method withusing master 8½ DMMFluke 8508 A

5 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

100 µA to 100 mA 0.03% Direct Method usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 64 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 65: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

6 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (300 Hz to 10kHz)

100 mA to 1 A 0.041% to 0.079% Direct Method usingmaster 8½ DMM Fluke8508 A

7 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Current (50 Hz) 20 A to 1000 A 0.5% to 1.0% Direct method masterUsing Shunt With DMM

8 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Inductance (1kHz) 100 µH to 100 mH 0.236% to 0.065% Direct Method usingmaster LCR meter

9 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Inductance (1kHz) 100 mH to 10 H 0.065% to 0.073% Direct Method usingLCR Meter

10 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

1 mV to 100 mV 0.820% to 0.014% Direct method usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 65 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 66: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

11 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

1 V to 100 V 0.017% to 0.011% Direct Method usingmaster 8½ DMM Fluke8508A

12 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (20 Hz to 50kHz)

100 mV to 1 V 0.014% to 0.017% Direct method usingmaster 8½ DMM Fluke8508A

13 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (45 Hz to 1kHz)

100 V to 1000 V 0.01% to 0.007% Direct Method usingmaster 8½ DMM Fluke8508 A

14 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (50 Hz) 1 kV to 25 kV 6.33% to 7.72% Direct Method by usingmaster H.V probeFluke 80K-40 withDMM Fluke 17B

15 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Measure)

Voltage (50 kHz to 500kHz)

1 V to 20 V 0.07% to 0.230% Direct Method usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 66 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 67: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

16 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance (1 kHz) 220 pF to 300 nF 5.79% to 0.27% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

17 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance (100 Hz) 1 µF to 30 µF 1.55% to 0.56% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

18 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Capacitance(1 kHz) 300 nF to 100 µF 0.27% to 1.13% Direct Method usingmaster StandardCalibrator Fluke 5522A& Decade CapacitanceBox

19 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 3.3 mA to 1 A 0.15% to 0.073% Direct Method by usingmaster StandardCalibrator Fluke 5522A

20 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 30 µA to 330 µA 0.54% to 0.17% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 67 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 68: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

21 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1 kHz) 330 µA to 3.3 mA 0.17% to 0.15% Direct Method by usingmaster StandardCalibrator Fluke 5522A

22 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (10Hz to 1kHz) 330 µA to 3.3 mA 0.25% to 0.26% Direct Method by usingmaster StandardCalibrator Fluke 5522A

23 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (10Hz to 1kHz) 3.3 mA to 3 A 0.26% to 0.23% Direct Method by usingmaster StandardCalibrator Fluke 5522A

24 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (1kHz) 1 A to 10 A 0.073% to 0.12% Direct Method by usingmaster StandardCalibrator Fluke 5522A

25 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (45 Hz to 5kHz)

3 A to 20 A 0.23% to 0.13% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 68 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 69: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

26 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Current (50 Hz) 20 A to 1000 A 0.68% to 0.37% Direct Method by usingmaster StandardCalibrator Fluke 5522A& current coil

27 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Inductance (1 kHz) 100 µH to 10 H 2.35 % to 1.14 % Direct Method usingmaster DecadeInductance Box

28 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50 Hz @ UPF 1.2 W to4.8 kW,0.01 A to 20A,120 V to 240 V

0.16% Direct Method usingmaster StandardCalibrator Fluke 5522A

29 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @ 0.5 Lag, 6 W

to 2.4 kW,0.01 A to20 A,120 V to240 V

0.46% Direct Method usingmaster StandardCalibrator Fluke 5522A

30 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @ 0.8 Lead 9.6W to 3.8 kW,0.01 A to20 A,120 V to 240 V

0.20% Direct Method usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 69 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 70: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

31 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power 50Hz @0.2 Lag, 2.4 W

to 960 W,0.01 A to20 A,120 V to240 V

0.56% Direct Method usingmaster StandardCalibrator Fluke 5522A

32 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power Factor 0.2 Lag to UPF 0.003 Direct Method usingmaster StandardCalibrator Fluke 5522A

33 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Power Factor 0.2 Lead to UPF 0.0003 Direct Method usingmaster StandardCalibrator Fluke 5522A

34 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

1 V to 30 V 0.080% to 0.042% Direct Method by usingmaster StandardCalibrator Fluke 5522A

35 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

100 mV to 1 V 0.086% to 0.080% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 70 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 71: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

36 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (10 Hz to 10kHz)

30 mV to 100 mV 0.12% to 0.086% Direct Method by usingmaster StandardCalibrator Fluke 5522A

37 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (100kHz) 30 mV to 30 V 0.452% to 0.054% Direct Method by usingmaster StandardCalibrator Fluke 5522A

38 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (100kHz) 30 V to 100 V 0.054% to 0.024% Direct Method by usingmaster StandardCalibrator Fluke 5522A

39 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45 Hz to 1kHz)

30 V to 300 V 0.20% to 0.022% Direct Method by usingmaster StandardCalibrator Fluke 5522A

40 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45 Hz to 1kHz)

300 V to 1000 V 0.022% to 0.035% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 71 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 72: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

41 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (450kHz) 30 mV to 3 V 1.116% to 0.121% Direct Method by usingmaster StandardCalibrator Fluke 5522A

42 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45Hz to10kHz)

1 mV to 3 mV 0.712% to 0.24% Direct Method by usingmaster StandardCalibrator Fluke 5522A

43 ELECTRO-TECHNICAL-ALTERNATINGCURRENT (< 1 GHZ)(Source)

Voltage (45Hz to10kHz)

3 mV to 30 mV 0.24% to 0.042% Direct Method by usingmaster StandardCalibrator Fluke 5522A

44 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 1 A to 20 A 0.080% to 0.052% Direct method by usingmaster 8½ DMM Fluke8508 A

45 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 1 mA to 100 mA 0.002% to 0.008% Direct method by usingmaster 8½ DMM Fluke8508 A

46 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 10 µA to 100 µA 0.0010% Direct method by usingmaster 8½ DMM Fluke8508 A

47 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 100 µA to 1 mA 0.001% to 0.002% Direct method by usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 72 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 73: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

48 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 100 mA to 1 A 0.062% to 0.080% Direct method by usingmaster 8½ DMM Fluke8508 A

49 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Current 20 A to 1000 A 1.19% Direct Method using8½ DMM Fluke 8508with Shunt

50 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 Gohm to 10 Gohm 0.116% to 0.133% Direct Method by Usingmaster 8½ DMM Fluke8508 A

51 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 Mohm to 10 Mohm 0.001% to 0.002% Direct Method by Usingmaster 8½ DMM Fluke8508 A

52 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 mohm to 100 mohm 0.061% to 0.207% Direct Method by Usingmaster LCR Meter &DRB

53 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 1 ohm to 100 ohm 0.0015% to 0.0010% Using LCR Meter &DRB

54 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 10 kohm to 100 kohm 0.0007% to 0.0008% Direct Method by Usingmaster 8½ DMM Fluke8508 A

55 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 10 Mohm to 100 Mohm 0.002% to 0.008% Direct method by usingmaster 8½ DMM Fluke8508 A

56 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 Mohm to 1 Gohm 0.008% to 0.116% Direct Method by Usingmaster 8½ DMM Fluke8508 A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 73 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 74: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

57 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 mohm to 150mohm

0.206% Direct Method by Usingmaster LCR Meter &DRB

58 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 ohm to 10 kohm 0.0010% to 0.0007% Direct Method by Usingmaster 8½ DMM Fluke8508 A

59 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 100 kohm to 1 Mohm 0.0008% to 0.001% Direct Method by Usingmaster 8½ DMM Fluke8508 A

60 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Resistance 150 mohm to 1 ohm 0.206% to 0.0015% Direct Method by usingmaste LCR Meter &DRB

61 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 1 kV to 20 kV 1.70% to 1.67% Direct Method by usingmaster H.V probeFluke 80K-40 withDMM Fluke 17B

62 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 1 mV to 100 mV 0.44% to 0.0003% Direct Method by usingmaster StandardCalibrator Fluke 5522A

63 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 1 V to 100 V 0.0002% to 0.0003% Direct Method by usingmaster DMM Fluke8508A

64 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 100 mV to 1 V 0.0003% to 0.0003% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 74 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 75: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

65 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 100 V to 1000 V 0.0004% to 0.0004% Direct Method by usingmaster StandardCalibrator Fluke 5522A

66 ELECTRO-TECHNICAL- DIRECTCURRENT (Measure)

Voltage 20 kV to 40 kV 1.67% to 1.65% Direct Method by usingmaster H.V probeFluke 80K-40 withDMM Fluke 17B

67 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 1 A to 10 A 0.027% to 0.063% Direct Method by usingmaster StandardCalibrator Fluke 5522A

68 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 1 mA to 100 mA 0.016% to 0.011% Direct Method by usingmaster StandardCalibrator Fluke 5522A

69 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 10 µA to 100 µA 0.25% to 0.023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

70 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 10 A to 20 A 0.063% to 0.11% Direct Method by usingmaster StandardCalibrator Fluke 5522A

71 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 100 µA to 1 mA 0.023% to 0.016% Direct Method by usingmaster StandardCalibrator Fluke 5522A

72 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 100 mA to 1 A 0.011% to 0.027% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 75 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 76: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

73 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Current 20 A to 200 A 0.5% Direct Method usingCurrent Source

74 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Power 10 W to 1 kW,1V to1000V, 1mA to 1000A.

0.08% to 0.45% Using Calibrator Fluke5522A with CurrentCoil Direct Method.

75 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

DC Power (1V to1000V, 1mA to 1000A)

1 KW to 19.9 KW 0.45% to 0.65% Using Calibrator Fluke5522A with current coilDirect Method.

76 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Oscilloscope 1 mV to 130 V 0.29% to 0.096% Direct Method

77 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 0.1 Mohm to 1 Gohm 5.89% to 4.91% Direct Method usingmaster of high stabilityDecade Megohm Box

78 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 Gohm to 100 Gohm 4.91% to 8.61% Direct Method usingmaster of high stabilityDecade Megohm Box

79 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 kohm to 10 kohm 0.0036% to 0.0035% Direct Method usingStandard CalibratorFluke 5522A

80 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 mohm 0.609% Direct Method usingfixed resistor box

81 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 Mohm to 10 Mohm 0.0041% to 0.014% Direct Method usingStandard CalibratorFluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 76 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 77: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

82 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 1 ohm to 10 ohm 0.10% to 0.015% Direct Method usingStandard CalibratorFluke 5522A

83 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 kohm to 100 kohm 0.0035% to 0.0034% Direct Method usingStandard CalibratorFluke 5522A

84 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 mohm 0.610% Direct Method usingfixed resistor box

85 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 Mohm to 300 Mohm 0.014% to 0.38% Direct Method usingStandard CalibratorFluke 5522A

86 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 10 ohm to 100 ohm 0.015% to 0.004% Direct Method usingStandard CalibratorFluke 5522A

87 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 Gohm to 1 Tohm 5.81% Direct Method usingmaster of high stabilityDecade Megohm Box

88 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 ohm to 1 kohm 0.004% to 0.0036% Direct Method usingStandard CalibratorFluke 5522A

89 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 100 kohm to 1 Mohm 0.0034% to 0.0041% Direct Method usingStandard CalibratorFluke 5522A

90 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 150 mohm 0.609% Direct Method usingfixed resistor box

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 77 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 78: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

91 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 150 mohm to 1 ohm 0.611% to 0.10% Direct Method usingStandard CalibratorFluke 5522A:

92 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 300 Mohm to 1 Gohm 0.38% to 1.78% Direct Method usingStandard CalibratorFluke 5522A

93 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Resistance 50 mohm 0.610% Direct Method usingsing fixed resistor box

94 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 1 mV to 10 mV 0.240% to 0.023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

95 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 1 V to 10 V 0.0015% to 0.0016% Direct Method usingmaster StandardCalibrator Fluke 5522A:

96 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 10 mV to 100 mV 0.023% to 0.0039% Direct Method by usingmaster StandardCalibrator Fluke 5522A

97 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 10 V to 1000 V 0.0016% to 0.0023% Direct Method by usingmaster StandardCalibrator Fluke 5522A

98 ELECTRO-TECHNICAL- DIRECTCURRENT (Source)

Voltage 100 mV to 1 V 0.0039% to 0.0015% Direct Method by usingmaster StandardCalibrator Fluke 5522A

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 78 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 79: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

99 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Amplitude-Sq wave /Oscilloscope (1 kHz)

1 mV to 55 Vp-p 0.6% to 0.3% Direct Method by usingmaster StandardCalibrator Fluke 5522A

100 ELECTRO-TECHNICAL-ELECTRICALEQUIPMENT (Source)

Bandwidth -Oscilloscope

50 kHz to 1 GHz 0.23% to 0.87% Direct Method usingmaster StandardCalibrator Fluke 5522A

101 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(B type)

600 °C to 1750 °C

0.53°C to 0.39°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

102 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller (Jtype)

-200 °C to 1200 °C 0.28°C to 0.31°C Direct Method by usingMaster used- StndCalibrator Fluke 5522A& 6½ DMM

103 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(K type)

-200 °C to 1350 °C 0.26°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

104 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(N type)

-200 °C to 1300 °C 0.48°C to 0.35°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 79 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 80: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

105 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(R type)

10 °C to 1750 °C 0.67°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A

106 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(RTD type)

-200 °C to 800 °C 0.05 °C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

107 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller(S type)

10 °C to 1450 °C 0.56°C to 0.54°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

108 ELECTRO-TECHNICAL-TEMPERATURESIMULATION(Measure)

Temperature Indicator /Recorder / Controller (Ttype)

-200 °C to 400 °C 0.60°C to 0.17°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

109 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(B type)

600 °C to 1750 °C 0.47°C to 0.11°C Direct Method by usingMaster StandardCalibrator fluke 5522A

110 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(E type)

-200 °C to 900 °C 0.20°C to 0.45°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 80 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 81: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

111 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller (Jtype)

-200 °C to 1200 °C 0.15°C to 0.25°C Direct Method by usingMaster StandardCalibrator fluke 5522A

112 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(K type)

-200 °C to 1350 °C 0.37°C to 0.48°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

113 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(N Type )

-200 °C to 1300 °C 0.45°C to 0.30°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

114 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(R type)

10 °C to 1750 °C 0.62°C to 0.44°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

115 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(RTD type)

-200 °C to 800 °C 0.071°C to 0.083°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

116 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller(S type)

10 °C to 1750 °C 0.61°C to 0.51°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

117 ELECTRO-TECHNICAL-TEMPERATURESIMULATION (Source)

Temperature Indicator /Recorder / Controller (Ttype)

-200 °C to 400 °C 0.55°C to 0.16°C Direct Method by usingMaster StandardCalibrator fluke 5522A& 6½ DMM

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 81 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 82: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

118 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Frequency 10 Hz to 1 GHz 0.0011% to 0.0024% Direct Method usingmaster FrequencyCounter Philips- PM6669

119 ELECTRO-TECHNICAL- TIME &FREQUENCY(Measure)

Timer 1 sec to 9000 sec 0.06% to 0.05% Comparison Method byusing master DigitalTimer Beltronics - 501

120 ELECTRO-TECHNICAL- TIME &FREQUENCY (Source)

Frequency 1 Hz to 1 GHz 0.004% to 0.006% Direct Method usingmaster StandardCalibrator Fluke 5522A

121 ELECTRO-TECHNICAL- TIME &FREQUENCY (Source)

Timer Marker /Oscilloscope

1 ns to 5 s 0.0003 sec Direct Method usingmaster StandardCalibrator Fluke 5522A

122 MECHANICAL-ACCELERATION ANDSPEED

Centrifuge / CentrifugalMotor / Speed (Non-Contact)

10 RPM to 15000 RPM 1.1% to 1.2% By Comparison methodby using Tachometer

123 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Bench Centre(Parallelity andcoaxiality)

Upto 500mm 7.0µm Using Taper Mandrel

124 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Height MeasuringSystem, Res: 0.1µm

0 mm to 1000 mm 5.4µm Using Gauge Block Set

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 82 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 83: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

125 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Profile Projector / VideoMeasuring System /Micro Scope

0 ° to 360 ° 50 min of arc Using Glass Anglegauge, Glass Scale

126 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Profile Projector / VideoMeasuring System /Micro Scope

Mag.: 10x to 100x 0.6% Using Glass Anglegauge, Glass Scale

127 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Profile Projector / VideoMeasuring System /Micro Scope (L.C.0.001 mm)

0 mm to 200 mm 2.4 µm Using Glass Anglegauge, Glass Scale

128 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Surface Plate ( Granite/ Cast Iron SurfacePlate)

6000 mm to 2000 mm 2.0 sqrt(L+ W/150)µm,L W in mm

Using Electronic Level

129 MECHANICAL-DIMENSION (BASICMEASURINGINSTRUMENT,GAUGE ETC.)

Tape Scale Calibrator 0 mm to 1000 mm 10.2µm Using Slip Gauge Setand Long Slip Gauges

130 MECHANICAL-HARDNESS TESTINGMACHINES

Brinell HardnessTesting Machine

HBW 5/750 & HBW10/3000

7.1% & 3.65% Using StandardHardness BlocksIS:1500 (Part 2):2013

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 83 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 84: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

131 MECHANICAL-HARDNESS TESTINGMACHINES

Rockwell Hardness HRA, HRBW, HRC 1.0 HRA, 1.2 HRBW,0.85 HRC

Using StandardHardness Blocks IS1586(Part2):2018

132 MECHANICAL-HARDNESS TESTINGMACHINES

Vickers HardnessTesting Machine

HV1, HV5, HV10,HV30

5.12%HV1, 3.72 HV5,2.5%HV10, 2.0% HV30

Using StandardHardness BlocksIS:1501(Part2)2013

133 MECHANICAL-PRESSUREINDICATING DEVICES

Digital / Dial VaccumGauges / Transmitters /Transducers.

0 bar to (-) 0.75 bar 0.014 bar Digital Pressure Gaugewith uncertainty of0.0008 bar. Procedurebased on ISO 3567 &ISO 27893 standards.

134 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(HYDRAULIC)Digital /Analog PressureGauges, PressureIndicator WithTransducer /Transmitter, PressureSwitch

0 bar to 1000 bar 0.15 bar Digital Pressure gaugewith uncertainty of0.021 bar. Procedurebased on DKD-R 6-1guidelines.

135 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(HYDRAULIC)Digital /Analog PressureGauges, PressureIndicator WithTransducer /Transmitter & PressureSwitches

0 bar to 700 bar 0.29 bar Digital Pressure gaugewith uncertainty of0.182 bar. Procedurebased on DKD-R 6-1guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 84 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 85: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

136 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC) Digital /Dial Gauges / PressureIndicator WithTransmitter /Transducer.

0 bar to 20 bar 0.014 bar Digital Pressure gaugewith uncertainty of0,01bar. Procedurebased on DKD-R 6-1guidelines.

137 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Pressure gauges,Magnehelic gauges,Differential PressureTransmitters, LowPressure Indicators/Transducers,Barometer

0 mbar to 500 mbar 0.31 mbar Digital Manometer withuncertainty of 0.06mbar. Procedure basedon DKD-R 6-1guidelines.

138 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Digital /Dial Gauges / PressureIndicator WithTransmitter /Transducer.

0 bar to 70 bar 0.04 bar Digital Pressure gaugewith uncertainty of0.022 bar. Procedurebased on DKD-R 6-1guidelines.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 85 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 86: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

139 MECHANICAL-PRESSUREINDICATING DEVICES

PRESSURE(PNEUMATIC)Pressure gauges, Magnehelicgauges, DifferentialPressure Transmitters,Low PressureIndicators/Transducers,Barometer.

0 mbar to 2000 mbar 2.14 mbar Digital Manometer withuncertainty of 1.03mbar. Procedure basedon DKD-R 6-1guidelines.

140 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.0001 mg

1 mg to 2.1 g 0.003mg Using StandardWeights of acccuracyClass E1 andprocedure based OIMLR-76: 2006.

141 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class Ii) Readability :1 mg

1 mg to 1 kg 0.002 g Using StandardWeights of accuracyClass E1 & E2, andprocedure as per OIMLR-76: 2006.

142 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 g to 20 kg 0.10 g Using StandardWeights of AccuracyClass E2 & F1.Procedure as per OIMLR-76: 2006.

143 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III)Readability :10 g

10 g to 100 kg 10.0 g Using StandardWeights of accuracyClass M1 andprocedure as per OIMLR76:2006

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 86 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 87: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

144 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.001 mg

1 mg to 5.1 g 0.005 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

145 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I) Readability :0.1 mg

1 mg to 200 g 0.06 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

146 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE( Class I)Readability :0.01 mg

1 mg to 50 g 0.011 mg Using StandardWeights of accuracyClass E1 andprocedure as per OIMLR-76: 2006.

147 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class II)Rwadability:10 mg

0.1 mg to 5 kg 0.011 g Using StandardWeights of AccuracyClass E1& E2 .Procedure as per OIMLR 76:2006.

148 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 g to 35 kg 0.97 g Using StandardWeights of accuracyClass F1& M1.Peocedure as perOIML R-76: 2006.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 87 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 88: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

149 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :100 mg

0.1 mg to 10 kg 0.037 g Using StandardWeights of AccuracyClass E1& E2.Procedure as per OIMLR-76: 2006.

150 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class III) Readability :50 g

2 kg to 500 kg 20.0 g Using StandardWeights of accuracyClass F2. Peocedureas per OIML R76:2006

151 MECHANICAL-WEIGHING SCALEAND BALANCE

Electronic WeighingBalance (ClassIII)Readability: 100 mg

0.1 mg to 2 kg 0.011 mg Using Weights ofAccuracy Class E1&E2 . Procedure as perOIML R 76:2006.

152 MECHANICAL-WEIGHING SCALEAND BALANCE

ELECTRONICWEIGHING BALANCE(Class IV)Readability :100 g

2 kg to 1000 kg 50.0 g Using StandardWeights of accuracyClass M1, procedureas per OIML R76:2006

153 THERMAL- SPECIFICHEAT & HUMIDITY

Humidity Chambers /Climatic Chamber /EnvironmentalChamber/HumidityGenerator/HumiditySource(Single or MultiPoint)

20 %RH to 95 %RH@25°C& 10°C to 50°C@ 50%RH

2.6%RH, 0.7°C Using Data Loggers byMulti channel Method

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 88 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 89: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

154 THERMAL-TEMPERATURE

Thermal FreezersChambers / Ovens /Incubators (IndustrialPurpose) &Furnace,Cold room,Freezer, Deep Freezer,TemperatureChamber,Hot Air Oven,Furnace, Liquid Bath,Muffle Furnace (MultiPoint)

-80 °C to 200 °C 1.6°C Using RTD / TC anddata Logger (Mapping)

155 THERMAL-TEMPERATURE

Thermal Freezers/Chambers / Ovens /Incubators (IndustrialPurpose) & Furnance -multipoint

200 °C to 1200 °C 2.5°C Using RTDThermometer & N TypeThermocouples withMultichannelTemperature Recorder

156 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

140 °C to 600 °C 0.64°C Using SPRT withIndicator & Dry BlockBath

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 89 / 90

Validity 27/10/2019 to 26/10/2021 Last Amended on 22/11/2019

Page 90: Laboratory Name VAIDYANATHESHWARA INSTRUMENTS ...viplgroup.com/images/scope.pdfS.No Discipline / Group Measurand or Reference Material/Type of instrument or material to be calibrated

S.No Discipline / Group Measurand orReferenceMaterial/Type ofinstrument ormaterial to becalibrated ormeasured / QuantityMeasured /Instrument

Measurement rangeand additionalparameters whereapplicable(Rangeand Frequency)

Calibration andMeasurementCapability(CMC)(±)

Calibration orMeasurementMethod orprocedure)

157 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

600 °C to 1200 °C 2.53°C Using Fluke S TypeThermocouple withIndicator & Dry BlockBath

158 THERMAL-TEMPERATURE

Thermocouples & RTDSensors/ TemperatureSensors with indicators/ Temperature gauges /Transmitters /Temperature Switches& Transmitters withIndicatators

-95 °C to 140 °C 0.18°C Using SPRT withIndicator & Dry blockBath

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name VAIDYANATHESHWARA INSTRUMENTS, NO. 301/A, 9TH MAIN ROAD, 3RDCROSS, RAJIV GANDHI NAGAR, BENGALURU, KARNATAKA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number CC-2473 Page No. : 90 / 90