lamotte eu test strip & test paper flyer · 2019-01-21 · water testing leader since 1919!...

2
Water Testing Leader Since 1919! Insta-TEST ® Test Strips & Test Papers We guarantee that your customers will love the convenience and reliability of Insta-TEST® strips in PopTop vials. The patented vial has a molded desiccant liner that protects the strips from moisture intru- sion and eliminates loose desiccant bags. Greater moisture protection and fast, reliable results make the Insta-TEST® strips an unbeatable test system!

Upload: others

Post on 09-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LaMotte EU Test Strip & Test Paper Flyer · 2019-01-21 · Water Testing Leader Since 1919! Insta-TEST® Test Strips & Test Papers We guarantee that your customers will love the convenience

Water Testing Leader Since 1919!

Insta-TEST® Test Strips & Test Papers

We guarantee that your customers will love the convenience and reliability of Insta-TEST® strips in PopTop vials. The patented vial has a molded desiccant liner that protects the strips from moisture intru-sion and eliminates loose desiccant bags. Greater moisture protection and fast, reliable results make the Insta-TEST® strips an unbeatable test system!

Page 2: LaMotte EU Test Strip & Test Paper Flyer · 2019-01-21 · Water Testing Leader Since 1919! Insta-TEST® Test Strips & Test Papers We guarantee that your customers will love the convenience

Test PapersThe chlorine and iodine are chemically treated paper strips. These are packaged with a color chart in a waterproof plastic vial. The 2951 and 2951HR are test strips. They are also packaged with a color chart in a waterproof plastic vial.

Test Factor Range CodeStrips

per VialTotal Chlorine 10, 50, 100, 200 ppm 4250-BJ 200

QAC 0, 100, 200, 300, 400, 500 ppm 3072-J 100

QAC 50, 100, 200, 400 ppm 2951 100

QAC HR 200, 400, 600, 1000, 1500 ppm 2951HR 50

Iodine 12, 25, 50, 100 ppm 2948-BJ 200

Test StripsIndividual pads on a polystyrene strip. These are packaged in the PopTop vial which is molded with a desiccant liner for protection from moisture. The QAC strips are specifi cally formulated to read all types of QAC.

Test Factor Range CodeStrips/

Vial5 Way for Natural Waters Nitrate: 0-200 ppm (0, 20, 40, 80, 160, 200)

Nitrite: 0-10.0 ppm (0, 0.5, 1.0, 3.0, 5.0, 10.0)pH: 6.0-9.0 (6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0)Alkalinity: 0-240 ppm (0, 40, 80, 120, 180, 240)Hardness: 0-180 ppm (0, 30, 60, 120, 180)

3038-G 25

6-Way for Drinking Water Free Chlorine: 0-10 ppm (0, 0.5, 1, 3, 5, 10)Total Chlorine: 0-10 ppm (0, 0.5, 1, 3, 5, 10)Total Hardness: 0-400 ppm (0, 50, 100, 200, 400)pH: 4-10 (4, 5, 6, 7, 8, 9, 10)Nitrite-N: 0-10 (0, 0.5, 1, 5, 10)Nitrate-N: 0-50 (0, 5, 10, 25, 50)

2933-G 25

Alkalinity 0-180 ppm (0, 40, 80, 120, 180) 2997 50

Ammonia 0-6.0 ppm (0, 0.5, 1.0, 3.0, 6.0) 3023-G 25

Chlorine Dioxide 0-10 ppm (0, 0.25, 0.5, 1, 3, 5, 10) 2999LR 50

Chlorine Dioxide 0-500 ppm (0, 10, 25, 50, 100, 250, 500) 3002 50

Chlorine, Free, Low Range 0-10 ppm (0, 0.5, 1, 3, 5, 10) 2964-G 25

Chlorine, Total, Low Range 0-10 ppm (0, 0.25, 0.5, 1, 3, 10) 2963LR-G 25

Chlorine, Total, Low Range 0-10 ppm (0, 0.25, 0.5, 1, 3, 10) 2963LR-J 100

Chlorine, Free & Total Free Chlorine: 0-10 ppm (0, 0.5, 1, 3, 5, 10)Total Chlorine: 0-10 ppm (0, 0.5, 1, 3, 5, 10)

3027-G 25

Chlorine, Free, High Range 0-800 ppm (0, 50, 100, 250, 500, 800) 3031 50

Chlorine, Total 0-5 ppm (0, 0.5, 1, 3, 5) 2979 50

Copper 0-3.0 ppm (0, 0.3, 0.6, 1, 3) 2991-G 25

Copper & Iron Copper 0-3.0 ppm, Iron 0-5.0 ppm 2994 25 ea.

Hardness, Low Range 0-180 ppm (0, 30, 60, 120, 180) 2981 50

Iron Iron 0-5 ppm (0, 0.3, 0.5, 1, 3, 5) 2935-G 25

Iron, pH, Hardness & Total Chlorine Iron 0-5 ppm, pH 4-10 ppm, Hardness 0-400 ppm, Total Chlorine 0-10 ppm 2992 25 ea.

Molybdenum Kit* 0-5 ppm (0, 0.5, 1, 2, 5) 3628-01 50

Nitrate & Nitrite Nitrate 0-50 ppm (0, 5, 10, 25, 50); Nitrite 0-10 ppm (0, 0.5, 1, 5, 10) 2996 50

pH Wide Range 4-10 pH (4, 5, 6, 7, 8, 9, 10) 2974 50

Peracetic Acid 0-160 ppm (0, 10, 20, 50, 85, 160) 3000 50

Peracetic Acid, Low Range 0-50 ppm (0, 5, 10, 20, 30, 50) 3000LR 50

Peracetic Acid, High Range 0-1000 ppm (0, 50, 100, 250, 500, 1000) 3000HR 50

Phosphate, Low Range 0-2,500 ppb (0, 100, 200, 300, 500, 1,000, 2,500ppb PO4); 0-2.5 ppm (0, 0.1, 0.2, 0.3, 0.5, 1.0, 2.5ppm)

3021-G-ENV 25

Hydrogen Peroxide, High Range 0-90 ppm (0, 15, 30, 50, 90) 2984 25

Hydrogen Peroxide 0-50 ppm (0, 1, 3, 10, 30, 50) 2984LR 25

pH & Total Chlorine, Wide Range pH 4-10 ppm (4, 5, 6, 7, 8, 9, 10); TCI 0-50 ppm (0, 1, 5, 10, 20, 50) 2987-G 25

QAC Dual Range Low: 0, 10, 20, 40, 80 ppm; High: 0, 100, 200, 400, 800 ppm 2934 50

* Kit includes pre-treatment reagents included in kit.

5004003002001000

QAC ppm

©2018 LaMotte Company •LaMotte EU Test Strip & Test Paper Flyer.indd • 3.18

Easy-to-Read Color Chart!

We also off er the following rolls of pH papers. Please contact us for pricing.

Code Range Code Range3-2950 0-14 2953 4.5-7.5

2954 0-13 2907 6.8-8.4

2956 1-11 2959 8-12

9674 3.0-5.5 2955 9-14

Water Testing Leader Since 1919!Unit 1A | Harris Road | Wedgnock Industrial Estate | Warwick | CV34 5JU | UKtel: +44 (0) 1926 498203 | [email protected] | www.lamotte-europe.com

Strips/ Vial25

25

50

25

50

50

25

25

100

25

50